1
|
Botte E, Cui Y, Magliaro C, Tenje M, Koren K, Rinaldo A, Stocker R, Behrendt L, Ahluwalia A. Size-related variability of oxygen consumption rates in individual human hepatic cells. LAB ON A CHIP 2024; 24:4128-4137. [PMID: 39069914 PMCID: PMC11334764 DOI: 10.1039/d4lc00204k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 07/22/2024] [Indexed: 07/30/2024]
Abstract
Accurate descriptions of the variability in single-cell oxygen consumption and its size-dependency are key to establishing more robust tissue models. By combining microfabricated devices with multiparameter identification algorithms, we demonstrate that single human hepatocytes exhibit an oxygen level-dependent consumption rate and that their maximal oxygen consumption rate is significantly lower than that of typical hepatic cell cultures. Moreover, we found that clusters of two or more cells competing for a limited oxygen supply reduced their maximal consumption rate, highlighting their ability to adapt to local resource availability and the presence of nearby cells. We used our approach to characterize the covariance of size and oxygen consumption rate within a cell population, showing that size matters, since oxygen metabolism covaries lognormally with cell size. Our study paves the way for linking the metabolic activity of single human hepatocytes to their tissue- or organ-level metabolism and describing its size-related variability through scaling laws.
Collapse
Affiliation(s)
- Ermes Botte
- Research Centre "E. Piaggio", University of Pisa, Pisa, Italy.
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Yuan Cui
- Department of Organismal Biology, Science for Life Laboratory, Uppsala University, Uppsala, Sweden.
- Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, Uppsala, Sweden
| | - Chiara Magliaro
- Research Centre "E. Piaggio", University of Pisa, Pisa, Italy.
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Maria Tenje
- Department of Materials Science and Engineering, Science for Life Laboratory, Uppsala University, Uppsala, Sweden
| | - Klaus Koren
- Aarhus University Centre for Water Technology, Department of Biology, Aahrus University, 8000 Aarhus, Denmark
| | - Andrea Rinaldo
- Laboratory of Ecohydrology ECHO/IIE/ENAC, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
- Department of Civil, Environmental and Architectural Engineering, University of Padova, Padova, Italy
| | - Roman Stocker
- Institute for Environmental Engineering, Department of Civil, Environmental and Geomatic Engineering, ETH Zurich, Zurich, Switzerland
| | - Lars Behrendt
- Department of Organismal Biology, Science for Life Laboratory, Uppsala University, Uppsala, Sweden.
| | - Arti Ahluwalia
- Research Centre "E. Piaggio", University of Pisa, Pisa, Italy.
- Department of Information Engineering, University of Pisa, Pisa, Italy
| |
Collapse
|
2
|
Lin S, Feng D, Han X, Li L, Lin Y, Gao H. Microfluidic platform for omics analysis on single cells with diverse morphology and size: A review. Anal Chim Acta 2024; 1294:342217. [PMID: 38336406 DOI: 10.1016/j.aca.2024.342217] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 01/04/2024] [Accepted: 01/04/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND Microfluidic techniques have emerged as powerful tools in single-cell research, facilitating the exploration of omics information from individual cells. Cell morphology is crucial for gene expression and physiological processes. However, there is currently a lack of integrated analysis of morphology and single-cell omics information. A critical challenge remains: what platform technologies are the best option to decode omics data of cells that are complex in morphology and size? RESULTS This review highlights achievements in microfluidic-based single-cell omics and isolation of cells based on morphology, along with other cell sorting methods based on physical characteristics. Various microfluidic platforms for single-cell isolation are systematically presented, showcasing their diversity and adaptability. The discussion focuses on microfluidic devices tailored to the distinct single-cell isolation requirements in plants and animals, emphasizing the significance of considering cell morphology and cell size in optimizing single-cell omics strategies. Simultaneously, it explores the application of microfluidic single-cell sorting technologies to single-cell sequencing, aiming to effectively integrate information about cell shape and size. SIGNIFICANCE AND NOVELTY The novelty lies in presenting a comprehensive overview of recent accomplishments in microfluidic-based single-cell omics, emphasizing the integration of different microfluidic platforms and their implications for cell morphology-based isolation. By underscoring the pivotal role of the specialized morphology of different cells in single-cell research, this review provides robust support for delving deeper into the exploration of single-cell omics data.
Collapse
Affiliation(s)
- Shujin Lin
- Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou, 350025, China; Central Laboratory at the Second Affiliated Hospital of Fujian University of Traditional Chinese Medicine, Fujian-Macao Science and Technology Cooperation Base of Traditional Chinese Medicine-Oriented Chronic Disease Prevention and Treatment, Innovation and Transformation Center, Fujian University of Traditional Chinese Medicine, China
| | - Dan Feng
- Biotechnology Research Institute, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Xiao Han
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, 350108, China.
| | - Ling Li
- Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou, 350025, China; The First Clinical Medical College of Fujian Medical University, Fuzhou, 350004, China; Hepatopancreatobiliary Surgery Department, The First Affiliated Hospital of Fujian Medical University, Fuzhou, 350004, China.
| | - Yao Lin
- Central Laboratory at the Second Affiliated Hospital of Fujian University of Traditional Chinese Medicine, Fujian-Macao Science and Technology Cooperation Base of Traditional Chinese Medicine-Oriented Chronic Disease Prevention and Treatment, Innovation and Transformation Center, Fujian University of Traditional Chinese Medicine, China; Collaborative Innovation Center for Rehabilitation Technology, Fujian University of Traditional Chinese Medicine, China.
| | - Haibing Gao
- Mengchao Hepatobiliary Hospital of Fujian Medical University, Fuzhou, 350025, China.
| |
Collapse
|
3
|
Chen Y, Zhu Y, Peng C, Wang X, Wu J, Chen H, Xu J. A Point-of-Care Nucleic Acid Quantification Method by Counting Light Spots Formed by LAMP Amplicons on a Paper Membrane. BIOSENSORS 2024; 14:139. [PMID: 38534246 DOI: 10.3390/bios14030139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 03/06/2024] [Accepted: 03/07/2024] [Indexed: 03/28/2024]
Abstract
Nucleic acid quantification, allowing us to accurately know the copy number of target nucleic acids, is significant for diagnosis, food safety, agricultural production, and environmental protection. However, current digital quantification methods require expensive instruments or complicated microfluidic chips, making it difficult to popularize in the point-of-care detection. Paper is an inexpensive and readily available material. In this study, we propose a simple and cost-effective paper membrane-based digital loop-mediated isothermal amplification (LAMP) method for nucleic acid quantification. In the presence of DNA fluorescence dyes, the high background signals will cover up the amplicons-formed bright spots. To reduce the background fluorescence signals, a quencher-fluorophore duplex was introduced in LAMP primers to replace non-specific fluorescence dyes. After that, the amplicons-formed spots on the paper membrane can be observed; thus, the target DNA can be quantified by counting the spots. Take Vibrio parahaemolyticus DNA detection as an instance, a good linear relationship is obtained between the light spots and the copy numbers of DNA. The paper membrane-based digital LAMP detection can detect 100 copies target DNA per reaction within 30 min. Overall, the proposed nucleic acid quantification method has the advantages of a simple workflow, short sample-in and answer-out time, low cost, and high signal-to-noise, which is promising for application in resourced limited areas.
Collapse
Affiliation(s)
- Yanju Chen
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Yuanyuan Zhu
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Cheng Peng
- Key Laboratory of Traceability for Agricultural Genetically Modified Organisms, Ministry of Agriculture and Rural Affairs, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China
| | - Xiaofu Wang
- Key Laboratory of Traceability for Agricultural Genetically Modified Organisms, Ministry of Agriculture and Rural Affairs, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China
| | - Jian Wu
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China
| | - Huan Chen
- Hangzhou Digital-Micro Biotech Co., Ltd., Hangzhou 311215, China
| | - Junfeng Xu
- Key Laboratory of Traceability for Agricultural Genetically Modified Organisms, Ministry of Agriculture and Rural Affairs, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China
| |
Collapse
|
4
|
Kannan S, Ko PL, Wu HM, Tung YC. Efficient single-cell oxygen consumption rate characterization based on frequency domain fluorescence lifetime imaging microscopy measurement and microfluidic platform. BIOMICROFLUIDICS 2023; 17:054105. [PMID: 37840539 PMCID: PMC10576626 DOI: 10.1063/5.0161752] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 09/29/2023] [Indexed: 10/17/2023]
Abstract
Cell metabolism is critical in regulating normal cell functions to maintain energy homeostasis. In order to monitor cell metabolism, the oxygen consumption rate (OCR) of cells has been characterized as an important factor. In conventional cell analysis, the cells are characterized in bulk due to technical limitations. However, the heterogeneity between the cells cannot be identified. Therefore, single-cell analysis has been proposed to reveal cellular functions and their heterogeneity. In this research, an approach integrating a microfluidic device and widefield frequency domain fluorescence imaging lifetime microscopy (FD-FLIM) for single-cell OCR characterization in an efficient manner is developed. The microfluidic device provides an efficient platform to trap and isolate single cells in microwells with the buffer saline containing an oxygen-sensitive phosphorescent dye. The oxygen tension variation within the microwells can be efficiently estimated by measuring the fluorescence lifetime change using the FD-FLIM, and the OCR values of the single cells can then be calculated. In the experiments, breast cancer (MCF-7) cells are exploited for the OCR measurement. The results demonstrate the functionality of the developed approach and show the heterogeneity among the cells. The developed approach possesses great potential to advance cellular metabolism studies with single-cell resolution.
Collapse
Affiliation(s)
| | | | - Hsiao-Mei Wu
- Department of Biomechatronics Engineering, National Taiwan University, Taipei, Taiwan
| | | |
Collapse
|
5
|
Zhang J, Xue J, Luo N, Chen F, Chen B, Zhao Y. Microwell array chip-based single-cell analysis. LAB ON A CHIP 2023; 23:1066-1079. [PMID: 36625143 DOI: 10.1039/d2lc00667g] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Single-cell profiling is key to uncover the cellular heterogeneity and drives deep understanding of cell fate. In recent years, microfluidics has become an ideal tool for single-cell profiling owing to its benefits of high throughput and automation. Among various microfluidic platforms, microwell has the advantages of simple operation and easy integration with in situ analysis ability, making it an ideal technique for single-cell studies. Herein, recent advances of single-cell analysis based on microwell array chips are summarized. We first introduce the design and preparation of different microwell chips. Then microwell-based cell capture and lysis strategies are discussed. We finally focus on advanced microwell-based analysis of single-cell proteins, nucleic acids, and metabolites. The challenges and opportunities for the development of microwell-based single-cell analysis are also presented.
Collapse
Affiliation(s)
- Jin Zhang
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| | - Jing Xue
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| | - Ningfeng Luo
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| | - Feng Chen
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| | - Badong Chen
- Institute of Artificial Intelligence and Robotics and the College of Artificial Intelligence, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| | - Yongxi Zhao
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi 710049, P. R. China.
| |
Collapse
|
6
|
Sandström N, Brandt L, Sandoz PA, Zambarda C, Guldevall K, Schulz-Ruhtenberg M, Rösener B, Krüger RA, Önfelt B. Live single cell imaging assays in glass microwells produced by laser-induced deep etching. LAB ON A CHIP 2022; 22:2107-2121. [PMID: 35470832 DOI: 10.1039/d2lc00090c] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Miniaturization of cell culture substrates enables controlled analysis of living cells in confined micro-scale environments. This is particularly suitable for imaging individual cells over time, as they can be monitored without escaping the imaging field-of-view (FoV). Glass materials are ideal for most microscopy applications. However, with current methods used in life sciences, glass microfabrication is limited in terms of either freedom of design, quality, or throughput. In this work, we introduce laser-induced deep etching (LIDE) as a method for producing glass microwell arrays for live single cell imaging assays. We demonstrate novel microwell arrays with deep, high-aspect ratio wells that have rounded, dimpled or flat bottom profiles in either single-layer or double-layer glass chips. The microwells are evaluated for microscopy-based analysis of long-term cell culture, clonal expansion, laterally organized cell seeding, subcellular mechanics during migration and immune cell cytotoxicity assays of both adherent and suspension cells. It is shown that all types of microwells can support viable cell cultures and imaging with single cell resolution, and we highlight specific benefits of each microwell design for different applications. We believe that high-quality glass microwell arrays enabled by LIDE provide a great option for high-content and high-resolution imaging-based live cell assays with a broad range of potential applications within life sciences.
Collapse
Affiliation(s)
- Niklas Sandström
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Ludwig Brandt
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Patrick A Sandoz
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Chiara Zambarda
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | - Karolin Guldevall
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
| | | | | | | | - Björn Önfelt
- Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden.
- Department of Microbiology, Tumour and Cell Biology, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
7
|
Manzoor AA, Romita L, Hwang DK. A review on microwell and microfluidic geometric array fabrication techniques and its potential applications in cellular studies. CAN J CHEM ENG 2020. [DOI: 10.1002/cjce.23875] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Ahmad Ali Manzoor
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Lauren Romita
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Dae Kun Hwang
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| |
Collapse
|
8
|
Romita L, Thompson S, Hwang DK. Rapid fabrication of sieved microwells and cross-flow microparticle trapping. Sci Rep 2020; 10:15687. [PMID: 32973304 PMCID: PMC7518267 DOI: 10.1038/s41598-020-72700-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 08/31/2020] [Indexed: 11/09/2022] Open
Abstract
The use of microwells is popular for a wide range of applications due to its' simplicity. However, the seeding of conventional microwells, which are closed at the bottom, is restricted to gravitational sedimentation for cell or particle deposition and therefore require lengthy settling times to maximize well occupancy. The addition of microfluidics to the capture process has accelerated cell or particle dispersion and improved capture ability but is mostly limited to gravitationally-driven settling for capture into the wells. An alternative approach to conventional closed-microwells, sieved microwells supersedes reliance on gravity by using hydrodynamic forces through the open pores at the bottom of the microwells to draw targets into the wells. We have developed a rapid fabrication method, based on flow lithography techniques, which allows us to easily customize the mesh pore sizes in a simple two-step process. Finally, by combining this microwell design with cross-flow trapping in a microfluidic two-layered channel, we achieve an 88 ± 6% well occupancy in under 10 s.
Collapse
Affiliation(s)
- Lauren Romita
- Department of Chemical Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada
| | - Shyan Thompson
- Department of Chemical Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada
| | - Dae Kun Hwang
- Department of Chemical Engineering, Ryerson University, 350 Victoria Street, Toronto, ON, M5B 2K3, Canada.
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST), A Partnership Between Ryerson University and St. Michael's Hospital, 30 Bond Street, Toronto, ON, M5B 1W8, Canada.
| |
Collapse
|
9
|
Sigaeva A, Ong Y, Damle VG, Morita A, van der Laan KJ, Schirhagl R. Optical Detection of Intracellular Quantities Using Nanoscale Technologies. Acc Chem Res 2019; 52:1739-1749. [PMID: 31187980 PMCID: PMC6639779 DOI: 10.1021/acs.accounts.9b00102] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Indexed: 12/11/2022]
Abstract
Optical probes that can be used to measure certain quantities with subcellular resolution give us access to a new level of information at which physics, chemistry, life sciences, and medicine become strongly intertwined. The emergence of these new technologies is owed to great advances in the physical sciences. However, evaluating and improving these methods to new standards requires a joint effort with life sciences and clinical practice. In this Account, we give an overview of the probes that have been developed for measuring a few highly relevant parameters at the subcellular scale: temperature, pH, oxygen, free radicals, inorganic ions, genetic material, and biomarkers. Luminescent probes are available in many varieties, which can be used for measuring temperature, pH, and oxygen. Since they are influenced by virtually any metabolic process in the healthy or diseased cell, these quantities are extremely useful to understand intracellular processes. Probes for them can roughly be divided into molecular dyes with a parameter dependent fluorescence or phosphorescence and nanoparticle platforms. Nanoparticle probes can provide enhanced photostability, measurement quality, and potential for multiple functionalities. Embedding into coatings can improve biocompatibility or prevent nonspecific interactions between the probe and the cellular environment. These qualities need to be matched however with good uptake properties, colloidal properties and eventually intracellular targeting to optimize their practical applicability. Inorganic ions constitute a broad class of compounds or elements, some of which play specific roles in signaling, while others are toxic. Their detection is often difficult due to the cross-talk with similar ions, as well as other parameters. The detection of free radicals, DNA, and biomarkers at extremely low levels has significant potential for biomedical applications. Their presence is linked more directly to physiological and clinical manifestations. Since existing methods for free radical detection are generally poor in sensitivity and spatiotemporal resolution, new reliable methods that are generally applicable can contribute greatly to advancing this topic in biology. Optical methods that detect DNA or RNA and protein biomarkers exist for intracellular applications, but are mostly relevant for the development of rapid point-of-care sample testing. To elucidate the inner workings of cells, focused multidisciplinary research is required to define the validity and limitations of a nanoparticle probe, in both physical and biological terms. Multifunctional platforms and those that are easily made compatible with conventional research equipment have an edge over other techniques in growing the body of research evidencing their versatility.
Collapse
Affiliation(s)
- Alina Sigaeva
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Yori Ong
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Viraj G. Damle
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Aryan Morita
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
- Dept.
Dental Biomedical Sciences, Faculty of Dentistry, Universitas Gadjah Mada, Yogyakarta 55281, Indonesia
| | - Kiran J. van der Laan
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
| | - Romana Schirhagl
- Groningen
University, University Medical
Center Groningen, Antonius
Deusinglaan 1, 9713 AV Groningen, The Netherlands
| |
Collapse
|
10
|
Hai P, Imai T, Xu S, Zhang R, Aft RL, Zou J, Wang LV. High-throughput, label-free, single-cell photoacoustic microscopy of intratumoral metabolic heterogeneity. Nat Biomed Eng 2019; 3:381-391. [PMID: 30936431 PMCID: PMC6544054 DOI: 10.1038/s41551-019-0376-5] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 02/26/2019] [Indexed: 12/11/2022]
Abstract
Intratumoral heterogeneity, which is manifested in almost all of the hallmarks of cancer, including the significantly altered metabolic profiles of cancer cells, represents a challenge to effective cancer therapy. High-throughput measurements of the metabolism of individual cancer cells would allow direct visualization and quantification of intratumoral metabolic heterogeneity, yet the throughputs of current measurement techniques are limited to about 120 cells per hour. Here, we show that single-cell photoacoustic microscopy can reach throughputs of approximately 12,000 cells per hour by trapping single cells with blood in an oxygen-diffusion-limited high-density microwell array and by using photoacoustic imaging to measure the haemoglobin oxygen change (that is, the oxygen consumption rate) in the microwells. We demonstrate the capability of this label-free technique by performing high-throughput single-cell oxygen-consumption-rate measurements of cultured cells and by imaging intratumoral metabolic heterogeneity in specimens from patients with breast cancer. High-throughput single-cell photoacoustic microscopy of oxygen consumption rates should enable the faster characterization of intratumoral metabolic heterogeneity.
Collapse
Affiliation(s)
- Pengfei Hai
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Toru Imai
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA
| | - Song Xu
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
| | - Ruiying Zhang
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Rebecca L Aft
- Department of Surgery, School of Medicine, Washington University, St. Louis, MO, USA
- John Cochran Veterans Hospital, St. Louis, MO, USA
| | - Jun Zou
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA.
- Caltech Optical Imaging Laboratory, Department of Electrical Engineering, California Institute of Technology, Pasadena, CA, USA.
| |
Collapse
|
11
|
Abstract
Single-cell omics studies provide unique information regarding cellular heterogeneity at various levels of the molecular biology central dogma. This knowledge facilitates a deeper understanding of how underlying molecular and architectural changes alter cell behavior, development, and disease processes. The emerging microchip-based tools for single-cell omics analysis are enabling the evaluation of cellular omics with high throughput, improved sensitivity, and reduced cost. We review state-of-the-art microchip platforms for profiling genomics, epigenomics, transcriptomics, proteomics, metabolomics, and multi-omics at single-cell resolution. We also discuss the background of and challenges in the analysis of each molecular layer and integration of multiple levels of omics data, as well as how microchip-based methodologies benefit these fields. Additionally, we examine the advantages and limitations of these approaches. Looking forward, we describe additional challenges and future opportunities that will facilitate the improvement and broad adoption of single-cell omics in life science and medicine.
Collapse
Affiliation(s)
- Yanxiang Deng
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| | - Amanda Finck
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| | - Rong Fan
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut 06511, USA; , ,
| |
Collapse
|
12
|
Grate JW, Liu B, Kelly RT, Anheier NC, Schmidt TM. Microfluidic Sensors with Impregnated Fluorophores for Simultaneous Imaging of Spatial Structure and Chemical Oxygen Gradients. ACS Sens 2019; 4:317-325. [PMID: 30609370 DOI: 10.1021/acssensors.8b00924] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Interior surfaces of polystyrene microfluidic structures were impregnated with the oxygen sensing dye Pt(II) tetra(pentafluorophenyl)porphyrin (PtTFPP) using a solvent-induced fluorophore impregnation (SIFI) method. Using this technique, microfluidic oxygen sensors are obtained that enable simultaneous imaging of both chemical oxygen gradients and the physical structure of the microfluidic interior. A gentle method of fluorophore impregnation using acetonitrile solutions of PtTFPP at 50 °C was developed leading to a 10-μm-deep region containing fluorophore. This region is localized at the surface to sense oxygen in the interior fluid during use. Regions of the device that do not contact the interior fluid pathways lack fluorophores and are dark in fluorescent imaging. The technique was demonstrated on straight microchannel and pore network devices, the latter having pillars of 300 μm diameter spaced center to center at 340 μm providing pore throats of 40 μm. Sensing within channels or pores and imaging across the pore network devices were performed using a Lambert LIFA-P frequency domain fluorescence lifetime imaging system on a Leica microscope platform. Calibrations of different devices prepared by the SIFI method were indistinguishable. Gradient imaging showed fluorescent regions corresponding to the fluid pore network, dark pillars, and fluorescent lifetime varying across the gradient, thus providing both physical and chemical imaging. More generally, the SIFI technique can impregnate the interior surfaces of other polystyrene containers, such as cuvettes or cell and tissue culture containers, to enable sensing of interior conditions.
Collapse
Affiliation(s)
- Jay W. Grate
- Pacific Northwest
National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Bingwen Liu
- Pacific Northwest
National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Ryan T. Kelly
- Pacific Northwest
National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Norman C. Anheier
- Pacific Northwest
National Laboratory, P.O. Box 999, Richland, Washington 99352, United States
| | - Thomas M. Schmidt
- Department of Ecology and Evolutionary Biology, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
13
|
Cao X, Mu L, Chen M, Bu C, Liang S, She G, Shi W. Single Silicon Nanowire‐Based Fluorescent Sensor for Endogenous Hypochlorite in an Individual Cell. ACTA ACUST UNITED AC 2018. [DOI: 10.1002/adbi.201800213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Xingxing Cao
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Lixuan Mu
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
| | - Min Chen
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Congcong Bu
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Sen Liang
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| | - Guangwei She
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
| | - Wensheng Shi
- Key Laboratory of Photochemical Conversion and Optoelectronic MaterialsTechnical Institute of Physics and ChemistryChinese Academy of Sciences Beijing 100190 China
- University of Chinese Academy of Sciences Beijing 100049 China
| |
Collapse
|
14
|
Gao Y, Li B, Singhal R, Fontecchio A, Pelleg B, Orynbayeva Z, Gogotsi Y, Friedman G. Perfusion double-channel micropipette probes for oxygen flux mapping with single-cell resolution. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2018; 9:850-860. [PMID: 29600146 PMCID: PMC5852649 DOI: 10.3762/bjnano.9.79] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Accepted: 02/21/2018] [Indexed: 06/08/2023]
Abstract
Measuring cellular respiration with single-cell spatial resolution is a significant challenge, even with modern tools and techniques. Here, a double-channel micropipette is proposed and investigated as a probe to achieve this goal by sampling fluid near the point of interest. A finite element model (FEM) of this perfusion probe is validated by comparing simulation results with experimental results of hydrodynamically confined fluorescent molecule diffusion. The FEM is then used to investigate the dependence of the oxygen concentration variation and the measurement signal on system parameters, including the pipette's shape, perfusion velocity, position of the oxygen sensors within the pipette, and proximity of the pipette to the substrate. The work demonstrates that the use of perfusion double-barrel micropipette probes enables the detection of oxygen consumption signals with micrometer spatial resolution, while amplifying the signal, as compared to sensors without the perfusion system. In certain flow velocity ranges (depending on pipette geometry and configuration), the perfusion flow increases oxygen concentration gradients formed due to cellular oxygen consumption. An optimal perfusion velocity for respiratory measurements on single cells can be determined for different system parameters (e.g., proximity of the pipette to the substrate). The optimum perfusion velocities calculated in this paper range from 1.9 to 12.5 μm/s. Finally, the FEM model is used to show that the spatial resolution of the probe may be varied by adjusting the pipette tip diameter, which may allow oxygen consumption mapping of cells within tissue, as well as individual cells at subcellular resolution.
Collapse
Affiliation(s)
- Yang Gao
- Department of Electrical and Computer Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Bin Li
- Department of Electrical and Computer Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Riju Singhal
- Department of Material Science and Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Adam Fontecchio
- Department of Electrical and Computer Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Ben Pelleg
- Department of Electrical and Computer Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Zulfiya Orynbayeva
- Department of Surgery, Drexel University, 245 N. 15th Street, Philadelphia, PA 19102, USA
| | - Yury Gogotsi
- Department of Material Science and Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| | - Gary Friedman
- Department of Electrical and Computer Engineering, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, USA
| |
Collapse
|
15
|
Lee-Montiel FT, George SM, Gough AH, Sharma AD, Wu J, DeBiasio R, Vernetti LA, Taylor DL. Control of oxygen tension recapitulates zone-specific functions in human liver microphysiology systems. Exp Biol Med (Maywood) 2017; 242:1617-1632. [PMID: 28409533 PMCID: PMC5661766 DOI: 10.1177/1535370217703978] [Citation(s) in RCA: 96] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Accepted: 03/07/2017] [Indexed: 12/20/2022] Open
Abstract
This article describes our next generation human Liver Acinus MicroPhysiology System (LAMPS). The key demonstration of this study was that Zone 1 and Zone 3 microenvironments can be established by controlling the oxygen tension in individual devices over the range of ca. 3 to 13%. The oxygen tension was computationally modeled using input on the microfluidic device dimensions, numbers of cells, oxygen consumption rates of hepatocytes, the diffusion coefficients of oxygen in different materials and the flow rate of media in the MicroPhysiology System (MPS). In addition, the oxygen tension was measured using a ratiometric imaging method with the oxygen sensitive dye, Tris(2,2'-bipyridyl) dichlororuthenium(II) hexahydrate (RTDP) and the oxygen insensitive dye, Alexa 488. The Zone 1 biased functions of oxidative phosphorylation, albumin and urea secretion and Zone 3 biased functions of glycolysis, α1AT secretion, Cyp2E1 expression and acetaminophen toxicity were demonstrated in the respective Zone 1 and Zone 3 MicroPhysiology System. Further improvements in the Liver Acinus MicroPhysiology System included improved performance of selected nonparenchymal cells, the inclusion of a porcine liver extracellular matrix to model the Space of Disse, as well as an improved media to support both hepatocytes and non-parenchymal cells. In its current form, the Liver Acinus MicroPhysiology System is most amenable to low to medium throughput, acute through chronic studies, including liver disease models, prioritizing compounds for preclinical studies, optimizing chemistry in structure activity relationship (SAR) projects, as well as in rising dose studies for initial dose ranging. Impact statement Oxygen zonation is a critical aspect of liver functions. A human microphysiology system is needed to investigate the impact of zonation on a wide range of liver functions that can be experimentally manipulated. Because oxygen zonation has such diverse physiological effects in the liver, we developed and present a method for computationally modeling and measuring oxygen that can easily be implemented in all MPS models. We have applied this method in a liver MPS in which we are then able to control oxygenation in separate devices and demonstrate that zonation-dependent hepatocyte functions in the MPS recapitulate what is known about in vivo liver physiology. We believe that this advance allows a deep experimental investigation on the role of zonation in liver metabolism and disease. In addition, modeling and measuring oxygen tension will be required as investigators migrate from PDMS to plastic and glass devices.
Collapse
Affiliation(s)
| | - Subin M George
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Computational and Systems Biology, University of Pittsburgh, Pittsburgh, PA 15260,USA
| | - Albert H Gough
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Computational and Systems Biology, University of Pittsburgh, Pittsburgh, PA 15260,USA
| | - Anup D Sharma
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Computational and Systems Biology, University of Pittsburgh, Pittsburgh, PA 15260,USA
| | - Juanfang Wu
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
| | - Richard DeBiasio
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
| | - Lawrence A Vernetti
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Computational and Systems Biology, University of Pittsburgh, Pittsburgh, PA 15260,USA
| | - D Lansing Taylor
- Drug Discovery Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
- Department of Computational and Systems Biology, University of Pittsburgh, Pittsburgh, PA 15260,USA
- Pittsburgh Cancer Institute, University of Pittsburgh, Pittsburgh, PA 15260, USA
| |
Collapse
|
16
|
Gruber P, Marques MPC, Szita N, Mayr T. Integration and application of optical chemical sensors in microbioreactors. LAB ON A CHIP 2017; 17:2693-2712. [PMID: 28725897 DOI: 10.1039/c7lc00538e] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
The quantification of key variables such as oxygen, pH, carbon dioxide, glucose, and temperature provides essential information for biological and biotechnological applications and their development. Microfluidic devices offer an opportunity to accelerate research and development in these areas due to their small scale, and the fine control over the microenvironment, provided that these key variables can be measured. Optical sensors are well-suited for this task. They offer non-invasive and non-destructive monitoring of the mentioned variables, and the establishment of time-course profiles without the need for sampling from the microfluidic devices. They can also be implemented in larger systems, facilitating cross-scale comparison of analytical data. This tutorial review presents an overview of the optical sensors and their technology, with a view to support current and potential new users in microfluidics and biotechnology in the implementation of such sensors. It introduces the benefits and challenges of sensor integration, including, their application for microbioreactors. Sensor formats, integration methods, device bonding options, and monitoring options are explained. Luminescent sensors for oxygen, pH, carbon dioxide, glucose and temperature are showcased. Areas where further development is needed are highlighted with the intent to guide future development efforts towards analytes for which reliable, stable, or easily integrated detection methods are not yet available.
Collapse
Affiliation(s)
- Pia Gruber
- Department of Biochemical Engineering, University College London, Gower Street, WC1E 6BT, London, UK.
| | | | | | | |
Collapse
|
17
|
Kelbauskas L, Glenn H, Anderson C, Messner J, Lee KB, Song G, Houkal J, Su F, Zhang L, Tian Y, Wang H, Bussey K, Johnson RH, Meldrum DR. A platform for high-throughput bioenergy production phenotype characterization in single cells. Sci Rep 2017; 7:45399. [PMID: 28349963 PMCID: PMC5368665 DOI: 10.1038/srep45399] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 02/23/2017] [Indexed: 02/06/2023] Open
Abstract
Driven by an increasing number of studies demonstrating its relevance to a broad variety of disease states, the bioenergy production phenotype has been widely characterized at the bulk sample level. Its cell-to-cell variability, a key player associated with cancer cell survival and recurrence, however, remains poorly understood due to ensemble averaging of the current approaches. We present a technology platform for performing oxygen consumption and extracellular acidification measurements of several hundreds to 1,000 individual cells per assay, while offering simultaneous analysis of cellular communication effects on the energy production phenotype. The platform comprises two major components: a tandem optical sensor for combined oxygen and pH detection, and a microwell device for isolation and analysis of single and few cells in hermetically sealed sub-nanoliter chambers. Our approach revealed subpopulations of cells with aberrant energy production profiles and enables determination of cellular response variability to electron transfer chain inhibitors and ion uncouplers.
Collapse
Affiliation(s)
- Laimonas Kelbauskas
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Honor Glenn
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Clifford Anderson
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Jacob Messner
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Kristen B. Lee
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Ganquan Song
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Jeff Houkal
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Fengyu Su
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Liqiang Zhang
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Yanqing Tian
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Hong Wang
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Kimberly Bussey
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Roger H. Johnson
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| | - Deirdre R. Meldrum
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, 1001S. McAllister Ave., Tempe, AZ 85287, USA
| |
Collapse
|
18
|
Zou X, Pan T, Chen L, Tian Y, Zhang W. Luminescence materials for pH and oxygen sensing in microbial cells - structures, optical properties, and biological applications. Crit Rev Biotechnol 2016; 37:723-738. [PMID: 27627832 DOI: 10.1080/07388551.2016.1223011] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Luminescence including fluorescence and phosphorescence sensors have been demonstrated to be important for studying cell metabolism, and diagnosing diseases and cancer. Various design principles have been employed for the development of sensors in different formats, such as organic molecules, polymers, polymeric hydrogels, and nanoparticles. The integration of the sensing with fluorescence imaging provides valuable tools for biomedical research and applications at not only bulk-cell level but also at single-cell level. In this article, we critically reviewed recent progresses on pH, oxygen, and dual pH and oxygen sensors specifically for their application in microbial cells. In addition, we focused not only on sensor materials with different chemical structures, but also on design and applications of sensors for better understanding cellular metabolism of microbial cells. Finally, we also provided an outlook for future materials design and key challenges in reaching broad applications in microbial cells.
Collapse
Affiliation(s)
- Xianshao Zou
- a Department of Materials Science and Engineering , South University of Science and Technology of China , Shenzhen , Guangdong , P.R. China
| | - Tingting Pan
- a Department of Materials Science and Engineering , South University of Science and Technology of China , Shenzhen , Guangdong , P.R. China
| | - Lei Chen
- b Laboratory of Synthetic Microbiology, School of Chemical Engineering & Technology , Tianjin University , Tianjin , P.R. China.,c Key Laboratory of Systems Bioengineering, Ministry of Education of China , Tianjin , P.R. China.,d SynBio Platform, Collaborative Innovation Center of Chemical Science and Engineering , Tianjin , P.R. China
| | - Yanqing Tian
- a Department of Materials Science and Engineering , South University of Science and Technology of China , Shenzhen , Guangdong , P.R. China
| | - Weiwen Zhang
- b Laboratory of Synthetic Microbiology, School of Chemical Engineering & Technology , Tianjin University , Tianjin , P.R. China.,c Key Laboratory of Systems Bioengineering, Ministry of Education of China , Tianjin , P.R. China.,d SynBio Platform, Collaborative Innovation Center of Chemical Science and Engineering , Tianjin , P.R. China
| |
Collapse
|
19
|
Pham TD, Wallace DC, Burke PJ. Microchambers with Solid-State Phosphorescent Sensor for Measuring Single Mitochondrial Respiration. SENSORS 2016; 16:s16071065. [PMID: 27409618 PMCID: PMC4970112 DOI: 10.3390/s16071065] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Revised: 06/20/2016] [Accepted: 07/05/2016] [Indexed: 11/16/2022]
Abstract
It is now well established that, even within a single cell, multiple copies of the mitochondrial genome may be present (genetic heteroplasmy). It would be interesting to develop techniques to determine if and to what extent this genetic variation results in functional variation from one mitochondrion to the next (functional heteroplasmy). Measuring mitochondrial respiration can reveal the organelles’ functional capacity for Adenosine triphosphate (ATP) production and determine mitochondrial damage that may arise from genetic or age related defects. However, available technologies require significant quantities of mitochondria. Here, we develop a technology to assay the respiration of a single mitochondrion. Our “micro-respirometer” consists of micron sized chambers etched out of borofloat glass substrates and coated with an oxygen sensitive phosphorescent dye Pt(II) meso-tetra(pentafluorophenyl)porphine (PtTFPP) mixed with polystyrene. The chambers are sealed with a polydimethylsiloxane layer coated with oxygen impermeable Viton rubber to prevent diffusion of oxygen from the environment. As the mitochondria consume oxygen in the chamber, the phosphorescence signal increases, allowing direct determination of the respiration rate. Experiments with coupled vs. uncoupled mitochondria showed a substantial difference in respiration, confirming the validity of the microchambers as single mitochondrial respirometers. This demonstration could enable future high-throughput assays of mitochondrial respiration and benefit the study of mitochondrial functional heterogeneity, and its role in health and disease.
Collapse
Affiliation(s)
- Ted D Pham
- Department of Biomedical Engineering, University of California, Irvine, CA 92697, USA.
| | - Douglas C Wallace
- Center for Mitochondrial and Epigenomic Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Peter J Burke
- Department of Biomedical Engineering, University of California, Irvine, CA 92697, USA.
- Department of Electrical Engineering, University of California, Irvine, CA 92697, USA.
| |
Collapse
|
20
|
Vajrala VS, Suraniti E, Rigoulet M, Devin A, Sojic N, Arbault S. PDMS microwells for multi-parametric monitoring of single mitochondria on a large scale: a study of their individual membrane potential and endogenous NADH. Integr Biol (Camb) 2016; 8:836-43. [PMID: 27384613 DOI: 10.1039/c6ib00064a] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Microwell arrays have been developed to monitor simultaneously, and on a large scale, multiple metabolic responses of single mitochondria. Wells of 50 to 1000 μm-diameter were prepared based on easy structuration of thin polydimethylsiloxane layers (PDMS; 100 μm thickness). Their surface treatment with oxygen plasma allowed the immobilization in situ and observation with time of populations of single isolated mitochondria. Their metabolic activities could be monitored individually by fluorescence microscopy under several activation/inhibition conditions. We measured the concomitant variations of two main metabolic parameters - the endogenous NADH level and the internal membrane potential difference Δψ owing to a cationic fluorescent probe (TMRM) - at energized, uncoupled and inhibited stages of the mitochondrial respiratory chain. Microwell arrays allowed analyses on large populations, and consequently statistical studies with a single organelle resolution. Thus, we observed rapid individual polarizations and depolarizations of mitochondria following their supply with the energetic substrate, while an averaged global polarization (increase of TMRM fluorescence within mitochondria) and NADH increase were detected for the whole population. In addition, statistical correlation studies show that the NADH content of all mitochondria tends toward a metabolic limit and that their polarization-depolarization ability is ubiquitous. These results demonstrate that PDMS microwell platforms provide an innovative approach to better characterize the individual metabolic status of isolated mitochondria, possibly as a function of their cell or organ origin or in different physio-pathological situations.
Collapse
|
21
|
Flexible Sheet-Type Sensor for Noninvasive Measurement of Cellular Oxygen Metabolism on a Culture Dish. PLoS One 2015; 10:e0143774. [PMID: 26624889 PMCID: PMC4666489 DOI: 10.1371/journal.pone.0143774] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 11/09/2015] [Indexed: 11/22/2022] Open
Abstract
A novel flexible sensor was developed for the noninvasive oxygen metabolism measurement of cultivated cells and tissues. This device is composed of a transparent double-layered polymer sheet of ethylene-vinyl alcohol (EVOH) and poly(dimethylsiloxane) (PDMS) having an array of microhole structures of 90 μm diameter and 50 μm depth on its surface. All the microhole structures were equipped with a 1-μm-thick optical chemical sensing layer of platinum porphyrin-fluoropolymer on their bottom. The three-dimensional microstructures of the sensor were fabricated by a newly developed simple and low-cost production method named self-aligned hot embossing. The device was designed to be attached slightly above the cells cultivated on a dish to form a temporarily closed microspace over the target cells during measurement. Since the change in oxygen concentration is relatively fast in the microcompartmentalized culture medium, a rapid evaluation of the oxygen consumption rate is possible by measuring the phosphorescence lifetime of the platinum porphyrin-fluoropolymer. The combined use of the device and an automated optical measurement system enabled the high-throughput sensing of cellular oxygen consumption (100 points/min). We monitored the oxygen metabolism of the human breast cancer cell line MCF7 on a Petri dish and evaluated the oxygen consumption rate to be 0.72 ± 0.12 fmol/min/cell. Furthermore, to demonstrate the utility of the developed sensing system, we demonstrated the mapping of the oxygen consumption rate of rat brain slices and succeeded in visualizing a clear difference among the layer structures of the hippocampus, i.e., the cornu ammonis (CA1 and CA3) and dentate gyrus (DG).
Collapse
|
22
|
Moore JS, Xantheas SS, Grate JW, Wietsma TW, Gratton E, Vasdekis AE. Modular Polymer Biosensors by Solvent Immersion Imprint Lithography. ACTA ACUST UNITED AC 2015; 54:98-103. [PMID: 27867256 DOI: 10.1002/polb.23961] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
We recently demonstrated Solvent Immersion Imprint Lithography (SIIL), a rapid benchtop microsystem prototyping technique, including polymer functionalization, imprinting and bonding. Here, we focus on the realization of planar polymer sensors using SIIL through simple solvent immersion without imprinting. We describe SIIL's impregnation characteristics, including an inherent mechanism that not only achieves practical doping concentrations, but their unexpected 2-fold enhancement compared to the immersion solution. Subsequently, we developed and characterized optical sensors for detecting molecular O2. To this end, a substantially high dynamic range is reported, including its control through the immersion duration, a manifestation of SIIL's modularity. Overall, SIIL exhibits the potential of improving the operating characteristics of polymer sensors, while significantly accelerating their prototyping, as it requires a few seconds of processing and no need for substrates or dedicated instrumentation. These are critical for O2 sensing as probed by way of example here, as well as any polymer permeable reactant.
Collapse
Affiliation(s)
- J S Moore
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - S S Xantheas
- Physical Sciences Division, Pacific Northwest National Laboratory, PO Box 999, Richland, WA, 99352, USA
| | - J W Grate
- Physical Sciences Division, Pacific Northwest National Laboratory, PO Box 999, Richland, WA, 99352, USA
| | - T W Wietsma
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - E Gratton
- Laboratory of Fluorescence Dynamics, Biomedical Engineering Department, University of California, Irvine, CA 92697, USA
| | - A E Vasdekis
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA, 99352, USA.; Department of Physics, University of Idaho, Moscow, ID, 83844, USA
| |
Collapse
|
23
|
Sun S, Ungerböck B, Mayr T. Imaging of oxygen in microreactors and microfluidic systems. Methods Appl Fluoresc 2015; 3:034002. [DOI: 10.1088/2050-6120/3/3/034002] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
24
|
Vasdekis AE, Stephanopoulos G. Review of methods to probe single cell metabolism and bioenergetics. Metab Eng 2015; 27:115-135. [PMID: 25448400 PMCID: PMC4399830 DOI: 10.1016/j.ymben.2014.09.007] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2014] [Revised: 09/18/2014] [Accepted: 09/19/2014] [Indexed: 11/26/2022]
Abstract
Single cell investigations have enabled unexpected discoveries, such as the existence of biological noise and phenotypic switching in infection, metabolism and treatment. Herein, we review methods that enable such single cell investigations specific to metabolism and bioenergetics. Firstly, we discuss how to isolate and immobilize individuals from a cell suspension, including both permanent and reversible approaches. We also highlight specific advances in microbiology for its implications in metabolic engineering. Methods for probing single cell physiology and metabolism are subsequently reviewed. The primary focus therein is on dynamic and high-content profiling strategies based on label-free and fluorescence microspectroscopy and microscopy. Non-dynamic approaches, such as mass spectrometry and nuclear magnetic resonance, are also briefly discussed.
Collapse
Affiliation(s)
- Andreas E Vasdekis
- Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, PO Box 999, Richland, WA 99354, USA.
| | - Gregory Stephanopoulos
- Department of Chemical Engineering, Massachusetts Institute of Technology, Room 56-469, Cambridge, MA 02139, USA.
| |
Collapse
|
25
|
Shi X, Gao W, Wang J, Chao SH, Zhang W, Meldrum DR. Measuring gene expression in single bacterial cells: recent advances in methods and micro-devices. Crit Rev Biotechnol 2014; 35:448-60. [DOI: 10.3109/07388551.2014.899556] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
26
|
Zhou X, Su F, Tian Y, Meldrum DR. Dually fluorescent core-shell microgels for ratiometric imaging in live antigen-presenting cells. PLoS One 2014; 9:e88185. [PMID: 24505422 PMCID: PMC3913776 DOI: 10.1371/journal.pone.0088185] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2013] [Accepted: 01/05/2014] [Indexed: 12/28/2022] Open
Abstract
Core-shell microgels containing sensors/dyes in a matrix were fabricated by two-stage free radical precipitation polymerization method for ratiometric sensing/imaging. The microgels composing of poly(N-isopropylacrylamide) (PNIPAm) shell exhibits a low critical solution temperature (LCST), underwent an entropically driven transition from a swollen state to a deswollen state, which exhibit a hydrodynamic radius of ∼450 nm at 25°C (in vitro) and ∼190 nm at 37°C (in vivo). The microgel’s ability of escaping from lysosome into cytosol makes the microgel be a potential candidate for cytosolic delivery of sensors/probes. Non-invasive imaging/sensing in Antigen-presenting cells (APCs) was feasible by monitoring the changes of fluorescence intensity ratios. Thus, these biocompatible microgels-based imaging/sensing agents may be expected to expand current molecular imaging/sensing techniques into methods applicable to studies in vivo, which could further drive APC-based treatments.
Collapse
Affiliation(s)
- Xianfeng Zhou
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, Arrizona, United States of America
| | - Fengyu Su
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, Arrizona, United States of America
| | - Yanqing Tian
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, Arrizona, United States of America
- * E-mail:
| | - Deirdre R. Meldrum
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, Arrizona, United States of America
| |
Collapse
|
27
|
Fitzgerald NS, Burgess LW, Yang JCY, Kim PJ, Jang SH, Jen AKY. Long-pulsed luminescence for the measurement of dissolved oxygen. APPLIED SPECTROSCOPY 2014; 68:315-323. [PMID: 24666948 DOI: 10.1366/13-07195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Thin-film luminescent sensors were used to measure dissolved oxygen in picoliter volumes for the purpose of monitoring single-cell oxygen consumption rates, and that work served as the motivation for the development of the method described here. A few different platinum porphyrin sensor materials were examined, with all measurements conducted microscopically. By employing convolution theory to understand observed responses, including an unexpected red luminescent emission from an optic, we developed a new, rapid method for the determination of exponential decay lifetime. This new method of long-pulsed luminescence offers substantially improved signal-to-noise ratios for detected signals as long as self-illumination sources are carefully controlled in the experimental set-up.
Collapse
Affiliation(s)
- Noel S Fitzgerald
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| | - Lloyd W Burgess
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| | - Jeffrey C-Y Yang
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| | - Prince J Kim
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| | - Sei-Hum Jang
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| | - Alex K-Y Jen
- University of Washington, Department of Chemistry, Seattle, WA 98195 USA
| |
Collapse
|
28
|
Marblestone AH, Zamft BM, Maguire YG, Shapiro MG, Cybulski TR, Glaser JI, Amodei D, Stranges PB, Kalhor R, Dalrymple DA, Seo D, Alon E, Maharbiz MM, Carmena JM, Rabaey JM, Boyden ES, Church GM, Kording KP. Physical principles for scalable neural recording. Front Comput Neurosci 2013; 7:137. [PMID: 24187539 PMCID: PMC3807567 DOI: 10.3389/fncom.2013.00137] [Citation(s) in RCA: 134] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2013] [Accepted: 09/23/2013] [Indexed: 12/20/2022] Open
Abstract
Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely new approaches may be required, motivating an analysis of the fundamental physical constraints on the problem. We outline the physical principles governing brain activity mapping using optical, electrical, magnetic resonance, and molecular modalities of neural recording. Focusing on the mouse brain, we analyze the scalability of each method, concentrating on the limitations imposed by spatiotemporal resolution, energy dissipation, and volume displacement. Based on this analysis, all existing approaches require orders of magnitude improvement in key parameters. Electrical recording is limited by the low multiplexing capacity of electrodes and their lack of intrinsic spatial resolution, optical methods are constrained by the scattering of visible light in brain tissue, magnetic resonance is hindered by the diffusion and relaxation timescales of water protons, and the implementation of molecular recording is complicated by the stochastic kinetics of enzymes. Understanding the physical limits of brain activity mapping may provide insight into opportunities for novel solutions. For example, unconventional methods for delivering electrodes may enable unprecedented numbers of recording sites, embedded optical devices could allow optical detectors to be placed within a few scattering lengths of the measured neurons, and new classes of molecularly engineered sensors might obviate cumbersome hardware architectures. We also study the physics of powering and communicating with microscale devices embedded in brain tissue and find that, while radio-frequency electromagnetic data transmission suffers from a severe power-bandwidth tradeoff, communication via infrared light or ultrasound may allow high data rates due to the possibility of spatial multiplexing. The use of embedded local recording and wireless data transmission would only be viable, however, given major improvements to the power efficiency of microelectronic devices.
Collapse
Affiliation(s)
- Adam H. Marblestone
- Biophysics Program, Harvard UniversityBoston, MA, USA
- Wyss Institute for Biologically Inspired Engineering at Harvard UniversityBoston, MA, USA
| | | | - Yael G. Maguire
- Department of Genetics, Harvard Medical SchoolBoston, MA, USA
- Plum Labs LLCCambridge, MA, USA
| | - Mikhail G. Shapiro
- Division of Chemistry and Chemical Engineering, California Institute of TechnologyPasadena, CA, USA
| | | | - Joshua I. Glaser
- Interdepartmental Neuroscience Program, Northwestern UniversityChicago, IL, USA
| | - Dario Amodei
- Department of Radiology, Stanford UniversityPalo Alto, CA, USA
| | | | - Reza Kalhor
- Department of Genetics, Harvard Medical SchoolBoston, MA, USA
| | - David A. Dalrymple
- Biophysics Program, Harvard UniversityBoston, MA, USA
- NemaloadSan Francisco, CA, USA
- Media Laboratory, Massachusetts Institute of TechnologyCambridge, MA, USA
| | - Dongjin Seo
- Department of Electrical Engineering and Computer Sciences, University of California at BerkeleyBerkeley, CA, USA
| | - Elad Alon
- Department of Electrical Engineering and Computer Sciences, University of California at BerkeleyBerkeley, CA, USA
| | - Michel M. Maharbiz
- Department of Electrical Engineering and Computer Sciences, University of California at BerkeleyBerkeley, CA, USA
| | - Jose M. Carmena
- Department of Electrical Engineering and Computer Sciences, University of California at BerkeleyBerkeley, CA, USA
- Helen Wills Neuroscience Institute, University of California at BerkeleyBerkeley, CA, USA
| | - Jan M. Rabaey
- Department of Electrical Engineering and Computer Sciences, University of California at BerkeleyBerkeley, CA, USA
| | - Edward S. Boyden
- Media Laboratory, Massachusetts Institute of TechnologyCambridge, MA, USA
- Departments of Brain and Cognitive Sciences and Biological Engineering, Massachusetts Institute of TechnologyCambridge, MA, USA
| | - George M. Church
- Biophysics Program, Harvard UniversityBoston, MA, USA
- Wyss Institute for Biologically Inspired Engineering at Harvard UniversityBoston, MA, USA
- Department of Genetics, Harvard Medical SchoolBoston, MA, USA
| | - Konrad P. Kording
- Departments of Physical Medicine and Rehabilitation and of Physiology, Northwestern University Feinberg School of MedicineChicago, IL, USA
- Sensory Motor Performance Program, The Rehabilitation Institute of ChicagoChicago, IL, USA
| |
Collapse
|
29
|
Colom A, Galgoczy R, Almendros I, Xaubet A, Farré R, Alcaraz J. Oxygen diffusion and consumption in extracellular matrix gels: implications for designing three-dimensional cultures. J Biomed Mater Res A 2013; 102:2776-84. [PMID: 24027235 DOI: 10.1002/jbm.a.34946] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2013] [Revised: 08/26/2013] [Accepted: 09/06/2013] [Indexed: 11/10/2022]
Abstract
Three-dimensional (3D) cultures are increasingly used as tissue surrogates to study many physiopathological processes. However, to what extent current 3D culture protocols provide physiologic oxygen tension conditions remains ill defined. To address this limitation, oxygen tension was measured in a panel of acellular or cellularized extracellular matrix (ECM) gels with A549 cells, and analyzed in terms of oxygen diffusion and consumption. Gels included reconstituted basement membrane, fibrin and collagen. Oxygen diffusivity in acellular gels was up to 40% smaller than that of water, and the lower values were observed in the denser gels. In 3D cultures, physiologic oxygen tension was achieved after 2 days in dense (≥3 mg/mL) but not sparse gels, revealing that the latter gels are not suitable tissue surrogates in terms of oxygen distribution. In dense gels, we observed a dominant effect of ECM composition over density in oxygen consumption. All diffusion and consumption data were used in a simple model to estimate ranges for gel thickness, seeding density and time-window that may support physiologic oxygen tension. Thus, we identified critical variables for oxygen tension in ECM gels, and introduced a model to assess initial values of these variables, which may short-cut the optimization step of 3D culture studies.
Collapse
Affiliation(s)
- Adai Colom
- Unitat de Biofísica i Bioenginyeria, Facultat de Medicina, Universitat de Barcelona, Barcelona, Spain
| | | | | | | | | | | |
Collapse
|
30
|
Chaturvedi P, Taguchi M, Burrs SL, Hauser BA, Salim WWAW, Claussen JC, McLamore ES. Emerging technologies for non-invasive quantification of physiological oxygen transport in plants. PLANTA 2013; 238:599-614. [PMID: 23846103 DOI: 10.1007/s00425-013-1926-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Accepted: 06/26/2013] [Indexed: 06/02/2023]
Abstract
Oxygen plays a critical role in plant metabolism, stress response/signaling, and adaptation to environmental changes (Lambers and Colmer, Plant Soil 274:7-15, 2005; Pitzschke et al., Antioxid Redox Signal 8:1757-1764, 2006; Van Breusegem et al., Plant Sci 161:405-414, 2001). Reactive oxygen species (ROS), by-products of various metabolic pathways in which oxygen is a key molecule, are produced during adaptation responses to environmental stress. While much is known about plant adaptation to stress (e.g., detoxifying enzymes, antioxidant production), the link between ROS metabolism, O2 transport, and stress response mechanisms is unknown. Thus, non-invasive technologies for measuring O2 are critical for understanding the link between physiological O2 transport and ROS signaling. New non-invasive technologies allow real-time measurement of O2 at the single cell and even organelle levels. This review briefly summarizes currently available (i.e., mainstream) technologies for measuring O2 and then introduces emerging technologies for measuring O2. Advanced techniques that provide the ability to non-invasively (i.e., non-destructively) measure O2 are highlighted. In the near future, these non-invasive sensors will facilitate novel experimentation that will allow plant physiologists to ask new hypothesis-driven research questions aimed at improving our understanding of physiological O2 transport.
Collapse
Affiliation(s)
- P Chaturvedi
- Agricultural and Biological Engineering Department, University of Florida, Gainesville, USA
| | | | | | | | | | | | | |
Collapse
|
31
|
Oxygen consumption rates of bacteria under nutrient-limited conditions. Appl Environ Microbiol 2013; 79:4921-31. [PMID: 23770901 DOI: 10.1128/aem.00756-13] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Many environments on Earth experience nutrient limitation and as a result have nongrowing or very slowly growing bacterial populations. To better understand bacterial respiration under environmentally relevant conditions, the effect of nutrient limitation on respiration rates of heterotrophic bacteria was measured. The oxygen consumption and population density of batch cultures of Escherichia coli K-12, Shewanella oneidensis MR-1, and Marinobacter aquaeolei VT8 were tracked for up to 200 days. The oxygen consumption per CFU (QO2) declined by more than 2 orders of magnitude for all three strains as they transitioned from nutrient-abundant log-phase growth to the nutrient-limited early stationary phase. The large reduction in QO2 from growth to stationary phase suggests that nutrient availability is an important factor in considering environmental respiration rates. Following the death phase, during the long-term stationary phase (LTSP), QO2 values of the surviving population increased with time and more cells were respiring than formed colonies. Within the respiring population, a subpopulation of highly respiring cells increased in abundance with time. Apparently, as cells enter LTSP, there is a viable but not culturable population whose bulk community and per cell respiration rates are dynamic. This result has a bearing on how minimal energy requirements are met, especially in nutrient-limited environments. The minimal QO2 rates support the extension of Kleiber's law to the mass of a bacterium (100-fg range).
Collapse
|
32
|
Hommes G, Gasser CA, Ammann EM, Corvini PFX. Determination of oxidoreductase activity using a high-throughput microplate respiratory measurement. Anal Chem 2012. [PMID: 23181606 DOI: 10.1021/ac302716j] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
High-throughput multiparallel activity profiling for oxygen consuming cell layers has been recently developed for extracellular flux analysis. This technology has great potential for determining the enzymatic activity of oxidoreductases (i.e., laccase) both in vivo and in vitro, which is usually measured using photometrical tests monitoring the colored oxidation products. Improvements in terms of sample throughput, comparability, and gain of information (i.e., stoichiometry, electron transfer rate) can be achieved by means of a multiwell plate-based fluorimetric oxygen sensor. In the present study, various laccases have been applied to develop protocols that allow the multiparallel measurement of O(2)-consumption by enzymatic reactions. The developed and validated method enables the comparative quantitation of laccase characteristics (i.e., profiles of activity at various pH values) and minimizes the time it usually takes to collect respiratory data of oxygen-consuming enzymes. Furthermore, the possibility to assess differences between single and multisubstrate kinetics of laccases has been demonstrated.
Collapse
Affiliation(s)
- Gregor Hommes
- Institute for Ecopreneurship, School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland
| | | | | | | |
Collapse
|
33
|
Grate JW, Kelly RT, Suter J, Anheier NC. Silicon-on-glass pore network micromodels with oxygen-sensing fluorophore films for chemical imaging and defined spatial structure. LAB ON A CHIP 2012; 12:4796-4801. [PMID: 22995983 DOI: 10.1039/c2lc40776k] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Pore network microfluidic models were fabricated by a silicon-on-glass technique that provides the precision advantage of dry etched silicon while creating a structure that is transparent across all microfluidic channels and pores, and can be imaged from either side. A silicon layer is bonded to an underlying borosilicate glass substrate and thinned to the desired height of the microfluidic channels and pores. The silicon is then patterned and through-etched by deep reactive ion etching (DRIE), with the underlying glass serving as an etch stop. After bonding on a transparent glass cover plate, one obtains a micromodel in oxygen impermeable materials with water-wet surfaces where the microfluidic channels are transparent and structural elements such as the pillars creating the pore network are opaque. The advantageous features of this approach in a chemical imaging application are demonstrated by incorporating a Pt porphyrin fluorophore in a PDMS film serving as the oxygen-sensing layer and a bonding surface, or in a polystyrene film coated with a PDMS layer for bonding. The sensing of a dissolved oxygen gradient was demonstrated using fluorescence lifetime imaging, and it is shown that different matrix polymers lead to optimal use in different ranges of oxygen concentration. Imaging with the opaque pillars in between the observation direction and the continuous fluorophore film yields images that retain defined spatial structure in the sensor image.
Collapse
Affiliation(s)
- Jay W Grate
- Pacific Northwest National Laboratory, P.O. Box 999, Richland, WA 99352, USA.
| | | | | | | |
Collapse
|
34
|
Zhu H, Zhou X, Su F, Tian Y, Ashili S, Holl MR, Meldrum DR. Micro-patterning and characterization of PHEMA-co-PAM-based optical chemical sensors for lab-on-a-chip applications. SENSORS AND ACTUATORS. B, CHEMICAL 2012; 173:817-823. [PMID: 23175599 PMCID: PMC3501128 DOI: 10.1016/j.snb.2012.07.101] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We report a novel method for wafer level, high throughput optical chemical sensor patterning, with precise control of the sensor volume and capability of producing arbitrary microscale patterns. Monomeric oxygen (O(2)) and pH optical probes were polymerized with 2-hydroxyethyl methacrylate (HEMA) and acrylamide (AM) to form spin-coatable and further crosslinkable polymers. A micro-patterning method based on micro-fabrication techniques (photolithography, wet chemical process and reactive ion etch) was developed to miniaturize the sensor film onto glass substrates in arbitrary sizes and shapes. The sensitivity of fabricated micro-patterns was characterized under various oxygen concentrations and pH values. The process for spatially integration of two sensors (Oxygen and pH) on the same substrate surface was also developed, and preliminary fabrication and characterization results were presented. To the best of our knowledge, it is the first time that poly (2-hydroxylethyl methacrylate)-co-poly (acrylamide) (PHEMA-co-PAM)-based sensors had been patterned and integrated at the wafer level with micron scale precision control using microfabrication techniques. The developed methods can provide a feasible way to miniaturize and integrate the optical chemical sensor system and can be applied to any lab-on-a-chip system, especially the biological micro-systems requiring optical sensing of single or multiple analytes.
Collapse
Affiliation(s)
- Haixin Zhu
- To whom all correspondence should be addressed. Tel.: +1 4809656488; Fax: +1, 4807276588;
| | | | | | | | | | | | | |
Collapse
|
35
|
Zhu H, Tian Y, Bhushan S, Su F, Meldrum DR. High Throughput Micropatterning of Optical Oxygen Sensor for Single Cell Analysis. IEEE SENSORS JOURNAL 2012; 12:1668-1672. [PMID: 23066352 PMCID: PMC3468159 DOI: 10.1109/jsen.2011.2176930] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
In this paper, we present our results from process development and characterization of optical oxygen sensors that are patterned by traditional UV lithography. An oxygen sensitive luminescent probe, platinum octaethylporphyrin (PtOEP), was encapsulated in commercially purchased photoresist (AZ5214) to form uniform thin sensor films on fused silica substrates. Plasticizer ethoxylated trimethylolpropane triacrylate (SR454) was added to the dye-photoresist sensor mixtures to improve the oxygen sensitivity. The optimum sensor mixture composition that can be patterned with maximum sensitivity was identified. The microfabrication process conditions, cell adherence and oxygen sensitivity results from patterned structures were characterized in detail. Down to 3 µm features have been fabricated on fused silica substrates using the developed techniques. The result implies the developed methods can provide a feasible way to miniaturize the optical sensor system for single cell analysis with precise control of sensor volume and response.
Collapse
|
36
|
Nanostructured oxygen sensor--using micelles to incorporate a hydrophobic platinum porphyrin. PLoS One 2012; 7:e33390. [PMID: 22457758 PMCID: PMC3310867 DOI: 10.1371/journal.pone.0033390] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2011] [Accepted: 02/13/2012] [Indexed: 12/04/2022] Open
Abstract
Hydrophobic platinum(II)-5,10,15,20-tetrakis-(2,3,4,5,6-pentafluorophenyl)-porphyrin (PtTFPP) was physically incorporated into micelles formed from poly(ε-caprolactone)-block-poly(ethylene glycol) to enable the application of PtTFPP in aqueous solution. Micelles were characterized using dynamic light scattering (DLS) and atomic force microscopy (AFM) to show an average diameter of about 140 nm. PtTFPP showed higher quantum efficiency in micellar solution than in tetrahydrofuran (THF) and dichloromethane (CH2Cl2). PtTFPP in micelles also exhibited higher photostability than that of PtTFPP suspended in water. PtTFPP in micelles exhibited good oxygen sensitivity and response time. This study provided an efficient approach to enable the application of hydrophobic oxygen sensors in a biological environment.
Collapse
|
37
|
Kelbauskas L, Ashili SP, Houkal J, Smith D, Mohammadreza A, Lee KB, Forrester J, Kumar A, Anis YH, Paulson TG, Youngbull CA, Tian Y, Holl MR, Johnson RH, Meldrum DR. Method for physiologic phenotype characterization at the single-cell level in non-interacting and interacting cells. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:037008. [PMID: 22502580 PMCID: PMC3602818 DOI: 10.1117/1.jbo.17.3.037008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2011] [Revised: 01/26/2012] [Accepted: 01/27/2012] [Indexed: 05/31/2023]
Abstract
Intercellular heterogeneity is a key factor in a variety of core cellular processes including proliferation, stimulus response, carcinogenesis, and drug resistance. However, cell-to-cell variability studies at the single-cell level have been hampered by the lack of enabling experimental techniques. We present a measurement platform that features the capability to quantify oxygen consumption rates of individual, non-interacting and interacting cells under normoxic and hypoxic conditions. It is based on real-time concentration measurements of metabolites of interest by means of extracellular optical sensors in cell-isolating microwells of subnanoliter volume. We present the results of a series of measurements of oxygen consumption rates (OCRs) of individual non-interacting and interacting human epithelial cells. We measured the effects of cell-to-cell interactions by using the system's capability to isolate two and three cells in a single well. The major advantages of the approach are: 1. ratiometric, intensity-based characterization of the metabolic phenotype at the single-cell level, 2. minimal invasiveness due to the distant positioning of sensors, and 3. ability to study the effects of cell-cell interactions on cellular respiration rates.
Collapse
|
38
|
Huang SH, Hsu YH, Wu CW, Wu CJ. Light-addressable measurements of cellular oxygen consumption rates in microwell arrays based on phase-based phosphorescence lifetime detection. BIOMICROFLUIDICS 2012; 6:44118. [PMID: 24348889 PMCID: PMC3555697 DOI: 10.1063/1.4772604] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2012] [Accepted: 12/04/2012] [Indexed: 05/02/2023]
Abstract
A digital light modulation system that utilizes a modified commercial digital micromirror device (DMD) projector, which is equipped with a UV light-emitting diode as a light modulation source, has been developed to spatially direct excited light toward a microwell array device to detect the oxygen consumption rate (OCR) of single cells via phase-based phosphorescence lifetime detection. The microwell array device is composed of a combination of two components: an array of glass microwells containing Pt(II) octaethylporphine (PtOEP) as the oxygen-sensitive luminescent layer and a microfluidic module with pneumatically actuated glass lids set above the microwells to controllably seal the microwells of interest. By controlling the illumination pattern on the DMD, the modulated excitation light can be spatially projected to only excite the sealed microwell for cellular OCR measurements. The OCR of baby hamster kidney-21 fibroblast cells cultivated on the PtOEP layer within a sealed microwell has been successfully measured at 104 ± 2.96 amol s(-1) cell(-1). Repeatable and consistent measurements indicate that the oxygen measurements did not adversely affect the physiological state of the measured cells. The OCR of the cells exhibited a good linear relationship with the diameter of the microwells, ranging from 400 to 1000 μm and containing approximately 480 to 1200 cells within a microwell. In addition, the OCR variation of single cells in situ infected by Dengue virus with a different multiplicity of infection was also successfully measured in real-time. This proposed platform provides the potential for a wide range of biological applications in cell-based biosensing, toxicology, and drug discovery.
Collapse
Affiliation(s)
- Shih-Hao Huang
- Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, No. 2, Beining Rd., Keelung 202-24, Taiwan ; Center for Marine Bioenvironment and Biotechnology (CMBB), National Taiwan Ocean University, Keelung 202-24, Taiwan
| | - Yu-Hsuan Hsu
- Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, No. 2, Beining Rd., Keelung 202-24, Taiwan
| | - Chih-Wei Wu
- Department of Mechanical and Mechatronic Engineering, National Taiwan Ocean University, No. 2, Beining Rd., Keelung 202-24, Taiwan
| | - Chang-Jer Wu
- Department of Food Science, National Taiwan Ocean University, Keelung 202-24, Taiwan
| |
Collapse
|
39
|
Zhou X, Su F, Tian Y, Johnson RH, Meldrum DR. Platinum (II) Porphyrin-Containing Thermoresponsive Poly(N-isopropylacrylamide) Copolymer as Fluorescence Dual Oxygen and Temperature Sensor. SENSORS AND ACTUATORS. B, CHEMICAL 2011; 159:135-141. [PMID: 21927540 PMCID: PMC3171833 DOI: 10.1016/j.snb.2011.06.061] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A random copolymer, poly(NIPAAm-co-PtPorphyrin), consisting of N-isopropylacrylamide (NIPAAm) and platinum (II) porphyrin units, behaves as an optical dual sensor for oxygen and temperature. The dual sensor is designed by incorporating an oxygen-sensitive platinum (II) porphyrin (M1) into a temperature-sensitive polymer (PNIPAAm). The polymer exhibited low critical solution temperature (LCST) property at 31.5 °C. This LCST affected the polymer's aggregation status, which in turn affected the nanostructures, fluorescence intensities, and responses to dissolved oxygen. This enables the polymer to functionalize as a dual temperature and dissolved oxygen sensor. Oxygen response of the platinum (II) porphyrin probes in the polymer followed a two-site Stern-Volmer model, indicating the nonuniform distribution of the probes. The copolymer was used to preliminarily monitor the oxygen consumption of Escherichia coli (E. coli) bacteria. The results indicate a potential application of the polymer in biological fields.
Collapse
Affiliation(s)
- Xianfeng Zhou
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287
| | - Fengyu Su
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287
| | - Yanqing Tian
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287
| | - Roger H. Johnson
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287
| | - Deirdre R. Meldrum
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, Tempe, AZ 85287
| |
Collapse
|
40
|
Pattappa G, Heywood HK, de Bruijn JD, Lee DA. The metabolism of human mesenchymal stem cells during proliferation and differentiation. J Cell Physiol 2011; 226:2562-70. [PMID: 21792913 DOI: 10.1002/jcp.22605] [Citation(s) in RCA: 227] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Human mesenchymal stem cells (MSCs) reside under hypoxic conditions in vivo, between 4% and 7% oxygen. Differentiation of MSCs under hypoxic conditions results in inhibited osteogenesis, while chondrogenesis is unaffected. The reasons for these results may be associated with the inherent metabolism of the cells. The present investigation measured the oxygen consumption, glucose consumption and lactate production of MSCs during proliferation and subsequent differentiation towards the osteogenic and chondrogenic lineages. MSCs expanded under normoxia had an oxygen consumption rate of ∼98 fmol/cell/h, 75% of which was azide-sensitive, suggesting that these cells derive a significant proportion of ATP from oxidative phosphorylation in addition to glycolysis. By contrast, MSCs differentiated towards the chondrogenic lineage using pellet culture had significantly reduced oxygen consumption after 24 h in culture, falling to ∼12 fmol/cell/h after 21 days, indicating a shift towards a predominantly glycolytic metabolism. By comparison, MSCs retained an oxygen consumption rate of ∼98 fmol/cell/h over 21 days of osteogenic culture conditions, indicating that these cells had a more oxidative energy metabolism than the chondrogenic cultures. In conclusion, osteogenic and chondrogenic MSC cultures appear to adopt the balance of oxidative phosphorylation and glycolysis reported for the respective mature cell phenotypes. The addition of TGF-β to chondrogenic pellet cultures significantly enhanced glycosaminoglycan accumulation, but caused no significant effect on cellular oxygen consumption. Thus, the differences between the energy metabolism of chondrogenic and osteogenic cultures may be associated with the culture conditions and not necessarily their respective differentiation.
Collapse
Affiliation(s)
- Girish Pattappa
- School of Engineering and Materials Science, Queen Mary University of London, London, UK
| | | | | | | |
Collapse
|
41
|
Zhou X, Su F, Gao W, Tian Y, Youngbull C, Johnson RH, Meldrum DR. Triazacryptand-based fluorescent sensors for extracellular and intracellular K+ sensing. Biomaterials 2011; 32:8574-83. [PMID: 21855134 DOI: 10.1016/j.biomaterials.2011.07.081] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2011] [Accepted: 07/28/2011] [Indexed: 02/01/2023]
Abstract
A 4-amino-naphthalimide derived fluorophore with a triazacryptand moiety ligand was synthesized as a potassium ion (K(+)) sensor (KS1). This sensor is a monomer possessing a polymerizable vinyl group. By taking advantage of the polymerizable characteristics of the vinyl group, KS1 was polymerized with 2-hydroxyethyl methacrylate (HEMA) and acrylamide (AM) to form K(+) sensing films for extracellular sensing. The sensitivity of the films to potassium ions can be further tuned through the adjustment of the HEMA and AM weight ratios as well as introduction of positive or negative charge-containing segments. KS1 and its poly(2-hydroxyethyl methacrylate)-co-poly(acrylamide) (PHEMA-co-PAM) thin films show high selectivity for K(+) over competing sodium ions (Na(+)) at physiological concentrations. Extracellular sensing was demonstrated using a KS1-conjugated PHEMA-co-PAM thin film to measure the K(+) efflux of Escherichia coli (E. coli) and Bacillus subtilis (B. subtilis) stimulated by lysozyme. Meanwhile, KS1 itself permeates human glioblastoma U87MG and human esophagus premalignant CP-A cell lines. KS1 was used to monitor K(+) efflux stimulated by adenosine-5'-triphosphate (ATP), amphotericin, and a mixture of nigericin, bumetanide and ouabain, demonstrating application of this material as an intracellular potassium ion sensor.
Collapse
Affiliation(s)
- Xianfeng Zhou
- Center for Biosignatures Discovery Automation, Biodesign Institute, Arizona State University, 1001S McAllister Ave, Tempe, AZ 85287, USA
| | | | | | | | | | | | | |
Collapse
|
42
|
Abstract
Respiration is widely used for evaluation of the metabolic capabilities or physiological state of the microbial culture. This chapter describes novel approaches for characterization of respiration at a single cell level: (1) flow cytometry-based redox sensing (FCRS) of actively metabolizing microbes; (2) respiration response imaging (RRI) for real-time detection of substrate stimulated redox responses of individual cells; (3) respiration detection system: microobservation chamber (RDS: MC), a single cell analysis system for carrying out the physiological and genomic profiling of cells capable of respiring C(1) compounds. The techniques are suitable for description of physiological heterogeneity among cells in a single microbial population and could be used to characterize distribution of methylotrophic ability among microbial cells in the natural environmental samples.
Collapse
|
43
|
Abstract
In the past decade, the tendency to move from a global, one-size-fits-all treatment philosophy to personalized medicine is based, in part, on the nuanced differences and sub-classifications of disease states. Our knowledge of these varied states stems from not only the ability to diagnose, classify, and perform experiments on cell populations as a whole, but also from new technologies that allow interrogation of cell populations at the individual cell level. Such departures from conventional thinking are driven by the recognition that clonal cell populations have numerous activities that manifest as significant levels of non-genetic heterogeneity. Clonal populations by definition originate from a single genetic origin so are regarded as having a high level of homogeneity as compared to genetically distinct cell populations. However, analysis at the single cell level has revealed a different phenomenon; cells and organisms require an inherent level of non-genetic heterogeneity to function properly, and in some cases, to survive. The growing understanding of this occurrence has lead to the development of methods to monitor, analyze, and better characterize the heterogeneity in cell populations. Following the trend of DNA- and protein microarrays, platforms capable of simultaneously monitoring each cell in a population have been developed. These cellular microarray platforms and other related formats allow for continuous monitoring of single live cells and simultaneously generate individual cell and average population data that are more descriptive and information-rich than traditional bulk methods. These technological advances have helped develop a better understanding of the intricacies associated with biological processes and afforded greater insight into complex biological systems. The associated instruments, techniques, and reagents now allow for highly multiplexed analyses, which enable multiple cellular activities, processes, or pathways to be monitored simultaneously. This critical review will discuss the paradigm shift associated with cellular heterogeneity, speak to the key developments that have lead to our better understanding of systems biology, and detail the future directions of the discipline (281 references).
Collapse
Affiliation(s)
- Maureen A Walling
- Department of Chemistry, University at Albany, SUNY, 1400 Washington Ave., Albany, NY 12222, USA
| | | |
Collapse
|
44
|
Toda M, Inomata N, Ono T. Bimorph Cantilevers Actuated by Focused Laser from the Side. ACTA ACUST UNITED AC 2011. [DOI: 10.1541/ieejsmas.131.327] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Masaya Toda
- Graduate School of Engineering, Tohoku University
| | | | - Takahito Ono
- Graduate School of Engineering, Tohoku University
| |
Collapse
|
45
|
Takeda M, Shiku H, Ino K, Matsue T. Electrochemical chip integrating scalable ring–ring electrode array to detect secreted alkaline phosphatase. Analyst 2011; 136:4991-6. [DOI: 10.1039/c1an15620a] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
46
|
Suzuki M, Ishikawa H, Tanaka A, Mataga I. Heterogeneity of anticancer drug sensitivity in squamous cell carcinoma of the tongue. Hum Cell 2010; 24:21-9. [PMID: 21547692 DOI: 10.1007/s13577-010-0004-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2010] [Accepted: 10/22/2010] [Indexed: 11/28/2022]
Abstract
Heterogeneity is known to be present to varying degrees in cancer cell groups. There have been no reports, however, of studies in which a single cell clone was prepared from a cancer cell group to examine heterogeneity with respect to anticancer drug sensitivity. Thus, the authors herein report an investigation into the heterogeneity of cancer cells within the same tumor with respect to anticancer drug sensitivity. Anticancer drug sensitivity was investigated in primary tumors, metastatic lymph node tumors, recurrent tumors and established cell lines obtained from four cases of tongue cancer using an oxygen electrode apparatus. As differences were observed in anticancer drug sensitivity from one case to another, even though all four were of the same pathological tissue type, the individual differences were apparently significant. Moreover, primary tumors and recurrent tumors demonstrated different sensitivities to the anticancer drugs even in the same patient. When single cell clones were prepared from primary tumors and anticancer drug sensitivity testing was carried out, sensitivity to anticancer drugs that was not seen in the primary tumors was observed. We performed RT-PCR on cell groups derived from this single cell using MDR1, MRP1, MRP2 and ERCC1, which are primary genes that are resistant to anticancer drugs. Expression of MDR and ERCC1 was not observed in single cell clones nos. 1-10. MRP1 and MRP2, on the other hand, were expressed in all of these single cell clones. Because cells with different sensitivity levels were initially present in the cancer cell groups, even when large numbers of cancer cells died in response to anticancer drug therapy, the results suggest the possibility that recurrence and metastasis occur based on cells with differing sensitivities. After examining anticancer drug sensitivity at the single cell level, we believe that anticancer drug-resistant genes may be involved in the heterogeneity of anticancer drug sensitivity with respect to cancer cell groups.
Collapse
Affiliation(s)
- Minako Suzuki
- Oral and Maxillofacial Surgery and Systemic Medicine, Graduate School of Life Dentistry at Niigata, The Nippon Dental University, Niigata, Japan.
| | | | | | | |
Collapse
|
47
|
Tian Y, Shumway BR, Gao W, Youngbull C, Holl MR, Johnson RH, Meldrum DR. Influence of Matrices on Oxygen Sensing of Three Sensing Films with Chemically Conjugated Platinum Porphyrin Probes and Preliminary Application for Monitoring of Oxygen Consumption of Escherichia coli (E. coli). SENSORS AND ACTUATORS. B, CHEMICAL 2010; 150:579-587. [PMID: 21076638 PMCID: PMC2976577 DOI: 10.1016/j.snb.2010.08.036] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Oxygen sensing films were synthesized by a chemical conjugation of functional platinum porphyrin probes in silica gel, polystyrene (PS), and poly(2-hydroxyethyl methacrylate) (PHEMA) matrices. Responses of the sensing films to gaseous oxygen and dissolved oxygen were studied and the influence of the matrices on the sensing behaviors was investigated. Silica gel films had the highest fluorescence intensity ratio from deoxygenated to oxygenated environments and the fastest response time to oxygen. PHEMA films had no response to gaseous oxygen, but had greater sensitivity and a faster response time for dissolved oxygen than those of PS films. The influence of matrices on oxygen response, sensitivity and response time was discussed. The influence is most likely attributed to the oxygen diffusion abilities of the matrices. Since the probes were chemically immobilized in the matrices, no leaching of the probes was observed from the sensing films when applied in aqueous environment. One sensing film made from the PHEMA matrix was used to preliminarily monitor the oxygen consumption of Escherichia coli (E. coli) bacteria. E. coli cell density and antibiotics ampicillin concentration dependent oxygen consumption was observed, indicating the potential application of the oxygen sensing film for biological application.
Collapse
Affiliation(s)
- Yanqing Tian
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Bradley R. Shumway
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Weimin Gao
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Cody Youngbull
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Mark R. Holl
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Roger H. Johnson
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| | - Deirdre R. Meldrum
- Center for Biosignatures Discovery Automation, The Biodesign Institute, Arizona State University, Tempe, AZ 85287-5001
| |
Collapse
|
48
|
Grist SM, Chrostowski L, Cheung KC. Optical oxygen sensors for applications in microfluidic cell culture. SENSORS (BASEL, SWITZERLAND) 2010; 10:9286-316. [PMID: 22163408 PMCID: PMC3230974 DOI: 10.3390/s101009286] [Citation(s) in RCA: 89] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2010] [Revised: 09/17/2010] [Accepted: 10/10/2010] [Indexed: 01/09/2023]
Abstract
The presence and concentration of oxygen in biological systems has a large impact on the behavior and viability of many types of cells, including the differentiation of stem cells or the growth of tumor cells. As a result, the integration of oxygen sensors within cell culture environments presents a powerful tool for quantifying the effects of oxygen concentrations on cell behavior, cell viability, and drug effectiveness. Because microfluidic cell culture environments are a promising alternative to traditional cell culture platforms, there is recent interest in integrating oxygen-sensing mechanisms with microfluidics for cell culture applications. Optical, luminescence-based oxygen sensors, in particular, show great promise in their ability to be integrated with microfluidics and cell culture systems. These sensors can be highly sensitive and do not consume oxygen or generate toxic byproducts in their sensing process. This paper presents a review of previously proposed optical oxygen sensor types, materials and formats most applicable to microfluidic cell culture, and analyzes their suitability for this and other in vitro applications.
Collapse
Affiliation(s)
- Samantha M. Grist
- Department of Electrical & Computer Engineering, University of British Columbia/2332 Main Mall, Vancouver, BC V6T 1Z4, Canada; E-Mails: (L.C.); (K.C.C.)
| | - Lukas Chrostowski
- Department of Electrical & Computer Engineering, University of British Columbia/2332 Main Mall, Vancouver, BC V6T 1Z4, Canada; E-Mails: (L.C.); (K.C.C.)
| | - Karen C. Cheung
- Department of Electrical & Computer Engineering, University of British Columbia/2332 Main Mall, Vancouver, BC V6T 1Z4, Canada; E-Mails: (L.C.); (K.C.C.)
| |
Collapse
|
49
|
Lidstrom ME, Konopka MC. The role of physiological heterogeneity in microbial population behavior. Nat Chem Biol 2010; 6:705-12. [PMID: 20852608 DOI: 10.1038/nchembio.436] [Citation(s) in RCA: 207] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
As the ability to analyze individual cells in microbial populations expands, it is becoming apparent that isogenic microbial populations contain substantial cell-to-cell differences in physiological parameters such as growth rate, resistance to stress and regulatory circuit output. Subpopulations exist that are manyfold different in these parameters from the population average, and these differences arise by stochastic processes. Such differences can dramatically affect the response of cells to perturbations, especially stress, which in turn dictates overall population response. Defining the role of cell-to-cell heterogeneity in population behavior is important for understanding population-based research problems, including those involving infecting populations, normal flora and bacterial populations in water and soils. Emerging technological breakthroughs are poised to transform single-cell analysis and are critical for the next phase of insights into physiological heterogeneity in the near future. These include technologies for multiparameter analysis of live cells, with downstream processing and analysis.
Collapse
Affiliation(s)
- Mary E Lidstrom
- Department of Chemical Engineering, University of Washington, Seattle, Washington, USA.
| | | |
Collapse
|
50
|
Pla-Roca M, Leulmi RF, Djambazian H, Sundararajan S, Juncker D. Addressable nanowell arrays formed using reversibly sealable hybrid elastomer-metal stencils. Anal Chem 2010; 82:3848-55. [PMID: 20377190 DOI: 10.1021/ac100335d] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
There are two major array formats used in life science research and biomedical analysis. The first is the microwell plate format with millimeter-sized wells each with microliter capacity addressed individually and repeatedly during experiments. The second is the microarray format with micrometer-sized spots that are patterned initially but not addressable individually thereafter. Here, we present an addressable nanoliter-well plate with micrometer sized wells that combines the advantages of the two array formats. The nanowells are formed by reversibly sealing a steel stencil featuring an array of micrometer-scale openings to an optically transparent substrate. The nanowells have a capacity of approximately 1 nL, are approximately 140 microm in diameter, and are arrayed at a density of 1600 wells cm(-2). A soft polymer is patterned photolithographically around each opening so as to form a microgasket for pressure sensitive, liquid tight, and reversible sealing to any type of smooth substrate, either hydrophilic or hydrophobic. The rigidity of the steel prevents the distortion that occurs in soft, all-polymeric stencils and permits accurate registration across the entire array, which in turn allows for repeated, individual addressing of wells using an inkjet spotter. The stencils are used to pattern cells, make protein microarrays, and create nanowells on surfaces to study reverse transfection by first spotting plasmids encoding fluorescent proteins into the wells, seeding cells, and monitoring the transfection of the cells in real time using time-lapse imaging. The hybrid elastomer-metal stencils (HEMSs) are versatile and useful for multiplexed analysis of drugs, biomolecules, and cells with microarray density.
Collapse
Affiliation(s)
- Mateu Pla-Roca
- Biomedical Engineering Department, McGill University, Montreal, Quebec, Canada H3A 1A4
| | | | | | | | | |
Collapse
|