1
|
Tunca N, Maral M, Yildiz E, Sengel SB, Erdem A. Synthesis and characterization of polysaccharide-cryogel and its application to the electrochemical detection of DNA. Mikrochim Acta 2024; 191:499. [PMID: 39088080 PMCID: PMC11294392 DOI: 10.1007/s00604-024-06550-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Accepted: 07/06/2024] [Indexed: 08/02/2024]
Abstract
The main goal of our study is to demonstrate the applicability of the PPy-cryogel-modified electrodes for electrochemical detection of DNA. First, a polysaccharide-based cryogel was synthesized. This cryogel was then used as a template for chemical polypyrrole synthesis. This prepared polysaccharide-based conductive cryogel was used for electrochemical biosensing on DNA. Carrageenan (CG) and sodium alginate (SA) polysaccharides, which stand out as biocompatible materials, were used in cryogel synthesis. Electron transfer was accelerated by polypyrrole (PPy) synthesized in cryogel networks. A 2B pencil graphite electrode with a diameter of 2.00 mm was used as a working electrode. The prepared polysaccharide solution was dropped onto a working electrode as a support material to improve the immobilization capacity of biomolecules and frozen to complete the cryogelation step. PPy synthesis was performed on the electrodes whose cryogelation process was completed. In addition, the structures of cryogels synthesized on the electrode surface were characterized by thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Surface characterization of the modified electrodes was performed by energy-dispersive X-ray spectroscopy (EDX) analysis. Electrochemical determination of fish sperm DNA (fsDNA) was performed using a PPy-cryogel-modified electrode. The use of a porous 3D cryogel intermediate material enhanced the signal by providing a large surface area for the synthesis of PPy and increasing the biomolecule immobilization capacity. The detection limit was 0.98 µg mL-1 in the fsDNA concentration range 2.5-20 µg mL-1. The sensitivity of the DNA biosensor was estimated to 14.8 µA mM-1 cm-2. The stability of the biosensor under certain storage conditions was examined and observed to remain 66.95% up to 45 days.
Collapse
Affiliation(s)
- Nilay Tunca
- The Institute of Natural and Applied Sciences, Biomedical Technologies Department, Ege University, Bornova, 35100, Izmir, Turkey
- Analytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova, 35100, Izmir, Turkey
- Faculty of Engineering and Architecture, Department of Biomedical Engineering, Eskisehir Osmangazi University, 26480, Eskisehir, Turkey
| | - Meltem Maral
- Analytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova, 35100, Izmir, Turkey
| | - Esma Yildiz
- Analytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova, 35100, Izmir, Turkey
| | - Sultan Butun Sengel
- Faculty of Engineering and Architecture, Department of Biomedical Engineering, Eskisehir Osmangazi University, 26480, Eskisehir, Turkey.
| | - Arzum Erdem
- Analytical Chemistry Department, Faculty of Pharmacy, Ege University, Bornova, 35100, Izmir, Turkey.
| |
Collapse
|
2
|
Zhao B, Xiong CR, Liu Y, Yu QC, Chen X. Rapid detection of SARS-CoV-2 spike protein using a magnetic-assisted electrochemical biosensor based on functionalized CoFe 2O 4 magnetic nanomaterials. Talanta 2024; 274:125986. [PMID: 38537348 DOI: 10.1016/j.talanta.2024.125986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Revised: 03/09/2024] [Accepted: 03/22/2024] [Indexed: 05/04/2024]
Abstract
The outbreak of novel coronavirus pneumonia (COVID-19) in 2019 has garnered widespread attention. The virus exhibits high contagiousness, and in certain cases, it can lead to recurrent infections. Therefore, it is imperative to develop portable, sensitive, and accurate sensors to promptly detect infected individuals, control the virus's transmission, and determine suitable treatment strategies. In this study, we proposed a magnetically-assisted method employing CFO@CS-Au MNP as the substrate material, which was functionalized with human angiotensin-converting enzyme (ACE2) for efficient capture of SARS-CoV-2 spike protein in solution. Subsequently, the captured protein was sensitively detected through differential pulse voltammetry (DPV) electrical analysis. The linear detection range of the labeled GCE/MNP/GA/ACE2/BSA electrochemical sensor is from 1 pg/mL to 10 μg/mL, with a minimum detection limit of 0.15 pg/mL. Furthermore, the fabricated GCE/MNP/GA/ACE2/BSA sensor achieved satisfactory recoveries of SARS-CoV-2 spike protein in saliva and nasal swab samples within 10 min. These results indicate that this magnetically-assisted biosensor has established a solid foundation for the swift on-site detection of COVID-19.
Collapse
Affiliation(s)
- Bing Zhao
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei, 230009, PR China; School of Materials Science and Engineering, Hefei University of Technology, Hefei, 230009, PR China
| | - Chan-Ru Xiong
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei, 230009, PR China; School of Resources and Environmental Engineering, Hefei University of Technology, Hefei, 230009, PR China
| | - Yao Liu
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei, 230009, PR China; School of Resources and Environmental Engineering, Hefei University of Technology, Hefei, 230009, PR China.
| | - Qing-Cai Yu
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei, 230009, PR China; School of Resources and Environmental Engineering, Hefei University of Technology, Hefei, 230009, PR China
| | - Xing Chen
- Key Lab of Aerospace Structural Parts Forming Technology and Equipment of Anhui Province, Institute of Industry and Equipment Technology, Hefei University of Technology, Hefei, 230009, PR China; School of Resources and Environmental Engineering, Hefei University of Technology, Hefei, 230009, PR China; School of Materials Science and Engineering, Hefei University of Technology, Hefei, 230009, PR China.
| |
Collapse
|
3
|
Huang Z, Zhang L, Dou Y, Liu X, Song S, Jiang H, Fan C. Electrochemical Biosensor for Point-of-Care Testing of Low-Abundance Biomarkers of Neurological Diseases. Anal Chem 2024; 96:10332-10340. [PMID: 38865206 DOI: 10.1021/acs.analchem.4c01278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
The neurofilament protein light chain (NEFL) is a potential biomarker of neurodegenerative diseases, and interleukin-6 (IL-6) is also closely related to neuroinflammation. Especially, NEFL and IL-6 are the two most low-abundance known protein markers of neurological diseases, making their detection very important for the early diagnosis and prognosis prediction of such kinds of diseases. Nevertheless, quantitative detection of low concentrations of NEFL and IL-6 in serum remains quite difficult, especially in the point-of-care test (POCT). Herein, we developed a portable, sensitive electrochemical biosensor combined with smartphones that can be applied to multiple scenarios for the quantitative detection of NEFL and IL-6, meeting the need of the POCT. We used a double-antibody sandwich configuration combined with polyenzyme-catalyzed signal amplification to improve the sensitivity of the biosensor for the detection of NEFL and IL-6 in sera. We could detect NEFL as low as 5.22 pg/mL and IL-6 as low as 3.69 pg/mL of 6 μL of serum within 2 h, demonstrating that this electrochemical biosensor worked well with serum systems. Results also showed its superior detection capabilities over those of high-sensitivity ELISA for serum samples. Importantly, by detecting NEFL and IL-6 in sera, the biosensor showed its potential for the POCT model detection of all known biomarkers of neurological diseases, making it possible for the mass screening of patients with neurodegenerative diseases.
Collapse
Affiliation(s)
- Ziyue Huang
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Lei Zhang
- Department of Anesthesiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China
| | - Yanzhi Dou
- Shanghai Institute of Microsystem and Information Technology, Chinse Academy of Sciences, Shanghai 200050, China
| | - Xue Liu
- Institute of Materiobiology, College of Science, Shanghai University, Shanghai 200444, China
| | - Shiping Song
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
- Institute of Materiobiology, College of Science, Shanghai University, Shanghai 200444, China
| | - Hong Jiang
- Department of Anesthesiology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200011, China
| | - Chunhai Fan
- Institute of Materiobiology, College of Science, Shanghai University, Shanghai 200444, China
- School of Chemistry and Chemical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
4
|
Fabiani L, Fiore L, Fillo S, D'Amore N, De Santis R, Lista F, Arduini F. Smartphone-assisted paper-based electrochemical immunosensor for SARS-CoV-2 detection in saliva. Bioelectrochemistry 2024; 156:108619. [PMID: 38128441 DOI: 10.1016/j.bioelechem.2023.108619] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 11/18/2023] [Accepted: 11/20/2023] [Indexed: 12/23/2023]
Abstract
Herein, we developed a new waste solution-free paper-based electrochemical immunosensor for SARS-CoV-2 detection in saliva, by combining vertical and lateral flow. In detail, the device was constituted of a reservoir containing all reagents for the construction of the immunological chain onto the magnetic beads and a lateral flow holder which contained a polyester-based electrode, a magnet, and an adsorbent pad. The measurement was carried out by adding the saliva sample into the reservoir, followed by the addition of this solution in the hole present in the lateral flow holder. The successive additions of washing buffer and TMB solution in the lateral flow holder allowed the detection of N protein in saliva in the range of 0.06 to 4 µg/mL with a detection limit equal to 30 ng/mL. The analysis of several saliva samples with the sensing tool and the reference method, demonstrated the effectiveness of this device, being able to identify positive patients with high values of CT e.g. 35. This new configuration paves the way for the realization of any magnetic beads-based immunosystem without waste solution production, enlarging the application of paper-based devices.
Collapse
Affiliation(s)
- Laura Fabiani
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Luca Fiore
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED, Via Bitonto 139, 00133, Rome, Italy
| | - Silvia Fillo
- Defence Institute for Biomedical Sciences, Via Santo Stefano Rotondo 4, 00184 Rome, Italy
| | - Nino D'Amore
- Defence Institute for Biomedical Sciences, Via Santo Stefano Rotondo 4, 00184 Rome, Italy
| | - Riccardo De Santis
- Defence Institute for Biomedical Sciences, Via Santo Stefano Rotondo 4, 00184 Rome, Italy
| | - Florigio Lista
- Defence Institute for Biomedical Sciences, Via Santo Stefano Rotondo 4, 00184 Rome, Italy
| | - Fabiana Arduini
- University of Rome "Tor Vergata", Department of Chemical Science and Technologies, Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED, Via Bitonto 139, 00133, Rome, Italy.
| |
Collapse
|
5
|
Osaki S, Saito M, Nagai H, Tamiya E. Surface Modification of Screen-Printed Carbon Electrode through Oxygen Plasma to Enhance Biosensor Sensitivity. BIOSENSORS 2024; 14:165. [PMID: 38667159 PMCID: PMC11048330 DOI: 10.3390/bios14040165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 03/25/2024] [Accepted: 03/25/2024] [Indexed: 04/28/2024]
Abstract
The screen-printed carbon electrode (SPCE) is a useful technology that has been widely used in the practical application of biosensors oriented to point-of-care testing (POCT) due to its characteristics of cost-effectiveness, disposability, miniaturization, wide potential window, and simple electrode design. Compared with gold or platinum electrodes, surface modification is difficult because the carbon surface is chemically or physically stable. Oxygen plasma (O2) can easily produce carboxyl groups on the carbon surface, which act as scaffolds for covalent bonds. However, the effect of O2-plasma treatment on electrode performance remains to be investigated from an electrochemical perspective, and sensor performance can be improved by clarifying the surface conditions of plasma-treated biosensors. In this research, we compared antibody modification by plasma treatment and physical adsorption, using our novel immunosensor based on gold nanoparticles (AuNPs). Consequently, the O2-plasma treatment produced carboxyl groups on the electrode surface that changed the electrochemical properties owing to electrostatic interactions. In this study, we compared the following four cases of SPCE modification: O2-plasma-treated electrode/covalent-bonded antibody (a); O2-plasma-treated electrode/physical adsorbed antibody (b); bare electrode/covalent-bonded antibody (c); and bare electrode/physical absorbed antibody (d). The limits of detection (LOD) were 0.50 ng/mL (a), 9.7 ng/mL (b), 0.54 ng/mL (c), and 1.2 ng/mL (d). The slopes of the linear response range were 0.039, 0.029, 0.014, and 0.022. The LOD of (a) was 2.4 times higher than the conventional condition (d), The slope of (a) showed higher sensitivity than other cases (b~d). This is because the plasma treatment generated many carboxyl groups and increased the number of antibody adsorption sites. In summary, the O2-plasma treatment was found to modify the electrode surface conditions and improve the amount of antibody modifications. In the future, O2-plasma treatment could be used as a simple method for modifying various molecular recognition elements on printed carbon electrodes.
Collapse
Affiliation(s)
- Shuto Osaki
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan (H.N.)
| | - Masato Saito
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan (H.N.)
- Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan
| | - Hidenori Nagai
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan (H.N.)
| | - Eiichi Tamiya
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, National Institute of Advanced Industrial Science and Technology, Photonics Center, Osaka University, 2-1 Yamadaoka, Suita 565-0871, Osaka, Japan (H.N.)
- SANKEN-The Institute of Scientific and Industrial Research, Osaka University, 8-1 Mihogaoka, Ibaraki 567-0047, Osaka, Japan
| |
Collapse
|
6
|
Yadav S, Sadique MA, Ranjan P, Khan R. Synergistically functionalized molybdenum disulfide-reduced graphene oxide nanohybrid based ultrasensitive electrochemical immunosensor for real sample analysis of COVID-19. Anal Chim Acta 2023; 1265:341326. [PMID: 37230571 DOI: 10.1016/j.aca.2023.341326] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Herein, we have proposed a straightforward and label-free electrochemical immunosensing strategy supported on a glassy carbon electrode (GCE) modified with a biocompatible and conducting biopolymer functionalized molybdenum disulfide-reduced graphene oxide (CS-MoS2/rGO) nanohybrid to investigate the SARS-CoV-2 virus. CS-MoS2/rGO nanohybrid-based immunosensor employs recombinant SARS-CoV-2 Spike RBD protein (rSP) that specifically identifies antibodies against the SARS-CoV-2 virus via differential pulse voltammetry (DPV). The antigen-antibody interaction diminishes the current responses of the immunosensor. The obtained results indicate that the fabricated immunosensor is extraordinarily capable of highly sensitive and specific detection of the corresponding SARS-CoV-2 antibodies with a LOD of 2.38 zg mL-1 in phosphate buffer saline (PBS) samples over a broad linear range between 10 zg mL-1-100 ng mL-1. In addition, the proposed immunosensor can detect attomolar concentrations in spiked human serum samples. The performance of this immunosensor is assessed using actual serum samples from COVID-19-infected patients. The proposed immunosensor can accurately and substantially differentiate between (+) positive and (-) negative samples. As a result, the nanohybrid can provide insight into the conception of Point-of-Care Testing (POCT) platforms for cutting-edge infectious disease diagnostic methods.
Collapse
Affiliation(s)
- Shalu Yadav
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Mohd Abubakar Sadique
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Pushpesh Ranjan
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India
| | - Raju Khan
- CSIR - Advanced Materials and Processes Research Institute (AMPRI), Bhopal - 462026, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad - 201002, India.
| |
Collapse
|
7
|
Dong T, Wang M, Liu J, Ma P, Pang S, Liu W, Liu A. Diagnostics and analysis of SARS-CoV-2: current status, recent advances, challenges and perspectives. Chem Sci 2023; 14:6149-6206. [PMID: 37325147 PMCID: PMC10266450 DOI: 10.1039/d2sc06665c] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 05/03/2023] [Indexed: 06/17/2023] Open
Abstract
The disastrous spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has induced severe public healthcare issues and weakened the global economy significantly. Although SARS-CoV-2 infection is not as fatal as the initial outbreak, many infected victims suffer from long COVID. Therefore, rapid and large-scale testing is critical in managing patients and alleviating its transmission. Herein, we review the recent advances in techniques to detect SARS-CoV-2. The sensing principles are detailed together with their application domains and analytical performances. In addition, the advantages and limits of each method are discussed and analyzed. Besides molecular diagnostics and antigen and antibody tests, we also review neutralizing antibodies and emerging SARS-CoV-2 variants. Further, the characteristics of the mutational locations in the different variants with epidemiological features are summarized. Finally, the challenges and possible strategies are prospected to develop new assays to meet different diagnostic needs. Thus, this comprehensive and systematic review of SARS-CoV-2 detection technologies may provide insightful guidance and direction for developing tools for the diagnosis and analysis of SARS-CoV-2 to support public healthcare and effective long-term pandemic management and control.
Collapse
Affiliation(s)
- Tao Dong
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
- School of Pharmacy, Medical College, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Mingyang Wang
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Junchong Liu
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Pengxin Ma
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Shuang Pang
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| | - Wanjian Liu
- Qingdao Hightop Biotech Co., Ltd 369 Hedong Road, Hi-tech Industrial Development Zone Qingdao 266112 China
| | - Aihua Liu
- Institute for Chemical Biology & Biosensing, College of Life Sciences, Qingdao University 308 Ningxia Road Qingdao 266071 China
| |
Collapse
|
8
|
Chen LC, Li MC, Chen KR, Cheng YJ, Wu XY, Chen SA, Youh MJ, Kuo CC, Lin YX, Lin CY, Wang CF, Huang CF, Lin SY, Wang WH, Chen YH, Yu ML, Thitithanyanont A, Wang SF, Su LC. Facile and Unplugged Surface Plasmon Resonance Biosensor with NIR-Emitting Perovskite Nanocomposites for Fast Detection of SARS-CoV-2. Anal Chem 2023; 95:7186-7194. [PMID: 37103881 PMCID: PMC10152400 DOI: 10.1021/acs.analchem.2c05661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 04/11/2023] [Indexed: 04/28/2023]
Abstract
The emergence of the coronavirus disease 2019 (COVID-19) pandemic prompted researchers to develop portable biosensing platforms, anticipating to detect the analyte in a label-free, direct, and simple manner, for deploying on site to prevent the spread of the infectious disease. Herein, we developed a facile wavelength-based SPR sensor built with the aid of a 3D printing technology and synthesized air-stable NIR-emitting perovskite nanocomposites as the light source. The simple synthesis processes for the perovskite quantum dots enabled low-cost and large-area production and good emission stability. The integration of the two technologies enabled the proposed SPR sensor to exhibit the characteristics of lightweight, compactness, and being without a plug, just fitting the requirements of on-site detection. Experimentally, the detection limit of the proposed NIR SPR biosensor for refractive index change reached the 10-6 RIU level, comparable with that of state-of-the-art portable SPR sensors. In addition, the bio-applicability of the platform was validated by incorporating a homemade high-affinity polyclonal antibody toward the SARS-CoV-2 spike protein. The results demonstrated that the proposed system was capable of discriminating between clinical swab samples collected from COVID-19 patients and healthy subjects because the used polyclonal antibody exhibited high specificity against SARS-CoV-2. Most importantly, the whole measurement process not only took less than 15 min but also needed no complex procedures or multiple reagents. We believe that the findings disclosed in this work can open an avenue in the field of on-site detection for highly pathogenic viruses.
Collapse
Affiliation(s)
- Lung-Chien Chen
- Department of Electro-Optical Engineering,
National Taipei University of Technology, Taipei 10608,
Taiwan
| | - Meng-Chi Li
- Thin Film Technology Center, National
Central University, Taoyuan 32001, Taiwan
- Optical Sciences Center, National Central
University, Taoyuan 32001, Taiwan
| | - Kai-Ren Chen
- Department of Optics and Photonics,
National Central University, Taoyuan 32001,
Taiwan
| | - Yu-Jui Cheng
- Department of Electronic Engineering,
Ming Chi University of Technology, New Taipei City 24301,
Taiwan
| | - Xun-Ying Wu
- Department of Mechanical Engineering, Ming Chi
University of Technology, New Taipei City 24301,
Taiwan
| | - Sih-An Chen
- Department of Electro-Optical Engineering,
National Taipei University of Technology, Taipei 10608,
Taiwan
| | - Meng-Jey Youh
- Department of Mechanical Engineering, Ming Chi
University of Technology, New Taipei City 24301,
Taiwan
| | - Chien-Cheng Kuo
- Thin Film Technology Center, National
Central University, Taoyuan 32001, Taiwan
- Department of Optics and Photonics,
National Central University, Taoyuan 32001,
Taiwan
| | - Yu-Xen Lin
- TeraOptics Corporation,
Taoyuan 32472, Taiwan
| | - Chih-Yen Lin
- Center for Tropical Medicine and Infectious Disease
Research, Kaohsiung Medical University, Kaohsiung 80708,
Taiwan
- Department of Medical Laboratory Science and
Biotechnology, Kaohsiung Medical University, Kaohsiung 80708,
Taiwan
| | - Chu-Feng Wang
- Clinical Microbiology Laboratory, Department of
Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
| | - Chung-Feng Huang
- Hepatobiliary Division, Department of
Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
- Ph.D. Program in Translational Medicine,
College of Medicine, Kaohsiung Medical University, Kaohsiung, and Academia
Sinica, Kaohsiung 80708, Taiwan
- Faculty of Internal Medicine and Hepatitis
Research Center, College of Medicine, and Center for Cohort Study, Kaohsiung
Medical University, Kaohsiung 80708, Taiwan
| | - Shang-Yi Lin
- Clinical Microbiology Laboratory, Department of
Laboratory Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
- Division of Infectious Disease, Department of
Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
| | - Wen-Hung Wang
- School of Medicine, College of Medicine,
National Sun Yat-Sen University, Kaohsiung 80424,
Taiwan
| | - Yen-Hsu Chen
- Center for Tropical Medicine and Infectious Disease
Research, Kaohsiung Medical University, Kaohsiung 80708,
Taiwan
- Division of Infectious Disease, Department of
Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
- School of Medicine, College of Medicine,
National Sun Yat-Sen University, Kaohsiung 80424,
Taiwan
| | - Ming-Lung Yu
- Hepatobiliary Division, Department of
Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
- School of Medicine, College of Medicine,
National Sun Yat-Sen University, Kaohsiung 80424,
Taiwan
| | - Arunee Thitithanyanont
- Department of Microbiology, Faculty of Science,
Mahidol University, Bangkok 10400,
Thailand
| | - Sheng-Fan Wang
- Center for Tropical Medicine and Infectious Disease
Research, Kaohsiung Medical University, Kaohsiung 80708,
Taiwan
- Department of Medical Laboratory Science and
Biotechnology, Kaohsiung Medical University, Kaohsiung 80708,
Taiwan
- Department of Medical Research,
Kaohsiung Medical University Hospital, Kaohsiung Medical
University, Kaohsiung 80708, Taiwan
| | - Li-Chen Su
- General Education Center, Ming
Chi University of Technology, New Taipei City 24301,
Taiwan
- Organic Electronics Research Center,
Ming Chi University of Technology, New Taipei City 24301,
Taiwan
| |
Collapse
|
9
|
Villa-Manso AM, Guerrero-Esteban T, Pariente F, Toyos-Rodríguez C, de la Escosura-Muñiz A, Revenga-Parra M, Gutiérrez-Sánchez C, Lorenzo E. Bifunctional Au@Pt/Au nanoparticles as electrochemiluminescence signaling probes for SARS-CoV-2 detection. Talanta 2023; 260:124614. [PMID: 37163926 PMCID: PMC10166582 DOI: 10.1016/j.talanta.2023.124614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 04/21/2023] [Accepted: 04/26/2023] [Indexed: 05/12/2023]
Abstract
A novel immunosensor based on electrochemiluminescence resonance energy transfer (ECL-RET) for the sensitive determination of N protein of the SARS-CoV-2 coronavirus is described. For this purpose, bifunctional core@shell nanoparticles composed of a Pt-coated Au core and finally decorated with small Au inlays (Au@Pt/Au NPs) have been synthesized to act as ECL acceptor, using [Ru (bpy)3]2+ as ECL donor. These nanoparticles are efficient signaling probes in the immunosensor developed. The proposed ECL-RET immunosensor has a wide linear response to the concentration of N protein of the SARS-CoV-2 coronavirus with a detection limit of 1.27 pg/mL. Moreover, it has a high stability and shows no response to other proteins related to different virus. The immunosensor has achieved the quantification of N protein of the SARS-CoV-2 coronavirus in saliva samples. Results are consistent with those provided by a commercial colorimetric ELISA kit. Therefore, the developed immunosensor provides a feasible and reliable tool for early and effective detection of the virus to protect the population.
Collapse
Affiliation(s)
- Ana M Villa-Manso
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Tamara Guerrero-Esteban
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Félix Pariente
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain
| | - Celia Toyos-Rodríguez
- NanoBioAnalysis Group, Departamento de Química Física y Analítica, Universidad de Oviedo, 33006, Oviedo, Spain; Biotechnology Institute of Asturias, Universidad de Oviedo, Edificio Santiago Gascon, 33006, Oviedo, Spain
| | - Alfredo de la Escosura-Muñiz
- NanoBioAnalysis Group, Departamento de Química Física y Analítica, Universidad de Oviedo, 33006, Oviedo, Spain; Biotechnology Institute of Asturias, Universidad de Oviedo, Edificio Santiago Gascon, 33006, Oviedo, Spain
| | - Mónica Revenga-Parra
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain.
| | - Cristina Gutiérrez-Sánchez
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain.
| | - Encarnación Lorenzo
- Grupo de Sensores Químicos y Biosensores, Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, 28049, Madrid, Spain; Institute for Advanced Research in Chemical Sciences (IAdChem), Universidad Autónoma de Madrid, 28049, Madrid, Spain; IMDEA-Nanociencia, Ciudad Universitaria de Cantoblanco, 28049, Madrid, Spain
| |
Collapse
|
10
|
Xing W, Li Q, Han C, Sun D, Zhang Z, Fang X, Guo Y, Ge F, Ding W, Luo Z, Zhang L. Customization of aptamer to develop CRISPR/Cas12a-derived ultrasensitive biosensor. Talanta 2023; 256:124312. [PMID: 36738621 DOI: 10.1016/j.talanta.2023.124312] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/22/2023] [Accepted: 01/26/2023] [Indexed: 02/04/2023]
Abstract
The CRISPR/Cas systems have provided wide biosensing applications. Particularly, the aptamer-involved CRISPR/Cas sensor system powerfully expanded to non-nucleic-acid targets. However, tailoring the sequence of the aptamer to explore the relationship between affinity and the activation of CRISPR/Cas12a trans-cleavage activity has not been reported yet. Herein, we developed a series of new aptamers toward the spike protein 1(S1) of SARS-CoV-2. Surface plasmon resonance measurements showed that the affinity of these aptamers to S1 was at the nM level. Subsequently, a "SET" effect (Sequence Essential Trans-cleavage activity) is discovered for the activation of CRISPR/Cas12a trans-cleavage activity. That is, an aptamer, as the activator, sequence needs to be tailored to activate CRISPR/Cas12a efficiently. A balance should be reached between affinity and activation ability. On the one hand, high affinity ensures target recognition performance, and on the other hand, activation can achieve adequate amplification and output of recognition signals. The optimized sequence (with 27 nucleotides, for short 27-nt) not only recognizes the target with a high affinity and specificity but also can trigger the CRISPR/Cas12a trans-cleavage activity efficiently, showing an excellent detection performance in electrochemical biosensors. The detection limit for SARS-CoV-2 S1 can be low at 1.5 pg mL-1. The new CRISPR/Cas12a-derived aptasensor also displays a remarkable ability to detect Beta, Delta, and Omicron variants but is selective toward other kinds of proteins. Above all, it is robust for point-of-care testing (POCT) in complex biological fluids, such as saliva, urine, and serum, and provides a universal and scalable detecting platform. Our results provide new insights into aptamer development and a different strategy for COVID-19 antigen detection and biosensor development.
Collapse
Affiliation(s)
- Wenping Xing
- State Key Laboratory of Medicinal Chemical Biology, College of Pharmacy, Nankai University, Tianjin, 300350, PR China
| | - Qian Li
- State Key Laboratory of Medicinal Chemical Biology, College of Pharmacy, Nankai University, Tianjin, 300350, PR China
| | - Cong Han
- State Key Laboratory of Medicinal Chemical Biology, College of Life Sciences, Nankai University, Tianjin, 300350, PR China
| | - Dongdong Sun
- State Key Laboratory of Medicinal Chemical Biology, College of Life Sciences, Nankai University, Tianjin, 300350, PR China
| | - Zheng Zhang
- The Cancer Hospital of the University of Chinese Academy of Sciences, Aptamer Selection Center, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, PR China
| | - Xiaona Fang
- The Cancer Hospital of the University of Chinese Academy of Sciences, Aptamer Selection Center, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, PR China
| | - Yu Guo
- State Key Laboratory of Medicinal Chemical Biology, College of Life Sciences, Nankai University, Tianjin, 300350, PR China
| | - Feng Ge
- Department of Gynecological Oncology, Tianjin Central Hospital of Obstetrics and Gynecology, Nankai University, Tianjin, 300071, PR China
| | - Wei Ding
- Department of Gynecological Oncology, Tianjin Central Hospital of Obstetrics and Gynecology, Nankai University, Tianjin, 300071, PR China
| | - Zhaofeng Luo
- The Cancer Hospital of the University of Chinese Academy of Sciences, Aptamer Selection Center, Institute of Basic Medicine and Cancer (IBMC), Chinese Academy of Sciences, Hangzhou, Zhejiang, 310022, PR China
| | - Liyun Zhang
- State Key Laboratory of Medicinal Chemical Biology, College of Life Sciences, Nankai University, Tianjin, 300350, PR China.
| |
Collapse
|
11
|
Dong T, Matos Pires NM, Yang Z, Jiang Z. Advances in Electrochemical Biosensors Based on Nanomaterials for Protein Biomarker Detection in Saliva. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205429. [PMID: 36585368 PMCID: PMC9951322 DOI: 10.1002/advs.202205429] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/20/2022] [Indexed: 06/02/2023]
Abstract
The focus on precise medicine enhances the need for timely diagnosis and frequent monitoring of chronic diseases. Moreover, the recent pandemic of severe acute respiratory syndrome coronavirus 2 poses a great demand for rapid detection and surveillance of viral infections. The detection of protein biomarkers and antigens in the saliva allows rapid identification of diseases or disease changes in scenarios where and when the test response at the point of care is mandated. While traditional methods of protein testing fail to provide the desired fast results, electrochemical biosensors based on nanomaterials hold perfect characteristics for the detection of biomarkers in point-of-care settings. The recent advances in electrochemical sensors for salivary protein detection are critically reviewed in this work, with emphasis on the role of nanomaterials to boost the biosensor analytical performance and increase the reliability of the test in human saliva samples. Furthermore, this work identifies the critical factors for further modernization of the nanomaterial-based electrochemical sensors, envisaging the development and implementation of next-generation sample-in-answer-out systems.
Collapse
Affiliation(s)
- Tao Dong
- Department of Microsystems‐ IMSFaculty of TechnologyNatural Sciences and Maritime SciencesUniversity of South‐Eastern Norway‐USNP.O. Box 235Kongsberg3603Norway
| | - Nuno Miguel Matos Pires
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
| | - Zhuangde Jiang
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
- State Key Laboratory for Manufacturing Systems EngineeringInternational Joint Laboratory for Micro/Nano Manufacturing and Measurement TechnologyXi'an Jiaotong UniversityXi'an710049China
| |
Collapse
|
12
|
Blasques RV, de Oliveira PR, Kalinke C, Brazaca LC, Crapnell RD, Bonacin JA, Banks CE, Janegitz BC. Flexible Label-Free Platinum and Bio-PET-Based Immunosensor for the Detection of SARS-CoV-2. BIOSENSORS 2023; 13:190. [PMID: 36831956 PMCID: PMC9954080 DOI: 10.3390/bios13020190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/14/2023] [Accepted: 01/20/2023] [Indexed: 06/18/2023]
Abstract
The demand for new devices that enable the detection of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) at a relatively low cost and that are fast and feasible to be used as point-of-care is required overtime on a large scale. In this sense, the use of sustainable materials, for example, the bio-based poly (ethylene terephthalate) (Bio-PET) can be an alternative to current standard diagnostics. In this work, we present a flexible disposable printed electrode based on a platinum thin film on Bio-PET as a substrate for the development of a sensor and immunosensor for the monitoring of COVID-19 biomarkers, by the detection of L-cysteine and the SARS-CoV-2 spike protein, respectively. The electrode was applied in conjunction with 3D printing technology to generate a portable and easy-to-analyze device with a low sample volume. For the L-cysteine determination, chronoamperometry was used, which achieved two linear dynamic ranges (LDR) of 3.98-39.0 μmol L-1 and 39.0-145 μmol L-1, and a limit of detection (LOD) of 0.70 μmol L-1. The detection of the SARS-CoV-2 spike protein was achieved by both square wave voltammetry (SWV) and electrochemical impedance spectroscopy (EIS) by a label-free immunosensor, using potassium ferro-ferricyanide solution as the electrochemical probe. An LDR of 0.70-7.0 and 1.0-30 pmol L-1, with an LOD of 0.70 and 1.0 pmol L-1 were obtained by SWV and EIS, respectively. As a proof of concept, the immunosensor was successfully applied for the detection of the SARS-CoV-2 spike protein in enriched synthetic saliva samples, which demonstrates the potential of using the proposed sensor as an alternative platform for the diagnosis of COVID-19 in the future.
Collapse
Affiliation(s)
- Rodrigo Vieira Blasques
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
- Department of Physics, Chemistry, and Mathematics, Federal University of São Carlos, Sorocaba 18052-780, Brazil
| | - Paulo Roberto de Oliveira
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | - Cristiane Kalinke
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
- Institute of Chemistry, University of Campinas, Campinas 13083-970, Brazil
| | - Laís Canniatti Brazaca
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA
| | - Robert D. Crapnell
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | | | - Craig E. Banks
- Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK
| | - Bruno Campos Janegitz
- Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil
| |
Collapse
|
13
|
Wang A, Li Y, You X, Zhang S, Zhou J, Liu H, Ding P, Chen Y, Qi Y, Liu Y, Liang C, Zhu X, Zhang Y, Liu E, Zhang G. Electrochemical immunosensor nanoarchitectonics with the Ag-rGO nanocomposites for the detection of receptor-binding domain of SARS-CoV-2 spike protein. J Solid State Electrochem 2023; 27:489-499. [PMID: 36466035 PMCID: PMC9707143 DOI: 10.1007/s10008-022-05330-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/27/2022] [Accepted: 11/01/2022] [Indexed: 11/30/2022]
Abstract
As the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) poses a grave threat to human life and health, it is essential to develop an efficient and sensitive detection method to identify infected individuals. This study described an electrode platform immunosensor to detect SARS-CoV-2-specific spike receptor-binding domain (RBD) protein based on a bare gold electrode modified with Ag-rGO nanocomposites and the biotin-streptavidin interaction system. The Ag-rGO nanocomposites was obtained by chemical synthesis and characterized by electrochemistry and scanning electron microscope (SEM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to record the electrochemical signals in the electrode modification. The differential pulse voltammetry (DPV) results showed that the limit of detection (LOD) of the immunosensor was 7.2 fg mL-1 and the linear dynamic detection range was 0.015 ~ 158.5 pg mL-1. Furthermore, this sensitive immunosensor accurately detected RBD in artificial saliva with favorable stability, specificity, and reproducibility, indicating that it has the potential to be used as a practical method for the detection of SARS-CoV-2.
Collapse
Affiliation(s)
- Aiping Wang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Yuya Li
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Xiaojuan You
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Shoutao Zhang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Jingming Zhou
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Hongliang Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Peiyang Ding
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Yumei Chen
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Yanhua Qi
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Yankai Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Chao Liang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Xifang Zhu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Ying Zhang
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Enping Liu
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| | - Gaiping Zhang
- School of Advanced Agricultural Sciences, Peking University, Beijing, 100871 China
- School of Life Sciences, Zhengzhou University, Zhengzhou, 450001 Henan China
- Longhu Laboratory of Advanced Immunology, Zhengzhou, Henan China
- College of Animal Science and Veterinary Medicine, Henan Agricultural University, Zhengzhou, 450002 Henan China
| |
Collapse
|
14
|
Liu J, Tang Y, Cheng Y, Huang W, Xiang L. Electrochemical biosensors based on saliva electrolytes for rapid detection and diagnosis. J Mater Chem B 2022; 11:33-54. [PMID: 36484271 DOI: 10.1039/d2tb02031a] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In recent years, electrochemical biosensors (ECBSs) have shown significant potential for real-time disease diagnosis and in situ physical condition monitoring. As a multi-constituent oral fluid comprising various disease signaling biomarkers, saliva has drawn much attention in the field of point-of-care (POC) testing. In particular, during the outbreak of the COVID-19 pandemic, ECBSs which hold the simplicity of a single-step assay compared with the multi-step assay of traditional testing methods are expected to relieve the human and economic burden caused by the massive and long-term sample testing process. Noteworthily, ECBSs for the detection of SARS-CoV-2 in saliva have already been developed and may replace current testing methods. Furthermore, the detection scope has expanded from routine indices such as sugar and uric acid to abnormal biomarkers for early-stage disease detection and drug level monitoring, which further facilitated the evolution of ECBSs in the last 5 years. This review is divided into several main sections. First, we discussed the latest advancements and representative research on ECBSs for saliva testing. Then, we focused on a novel kind of ECBS, organic electrochemical transistors (OECTs), which hold great advantages of high sensitivity and signal-to-noise ratio and on-site detection. Finally, application of ECBSs with integrated portable platforms in oral cavities, which lead to powerful auxiliary testing means for telemedicine, has also been discussed.
Collapse
Affiliation(s)
- Jiayi Liu
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China.
| | - Yufei Tang
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China. .,Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China
| | - Yuhua Cheng
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
| | - Wei Huang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
| | - Lin Xiang
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China. .,Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China
| |
Collapse
|
15
|
Kowalczyk A, Kasprzak A, Ruzycka-Ayoush M, Podsiadły E, Demkow U, Grudzinski IP, Nowicka AM. Ultrasensitive voltammetric detection of SARS-CoV-2 in clinical samples. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 371:132539. [PMID: 36033923 PMCID: PMC9395233 DOI: 10.1016/j.snb.2022.132539] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 06/15/2023]
Abstract
In every pandemic, it is critical to test as many people as possible and keep track of the number of new cases of infection. Therefore, there is a need for novel, fast and unambiguous testing methods. In this study, we designed a sandwich-type voltammetric immunosensor based on unlabeled- and labeled with a redox probe antibodies against virus spike protein for fast and ultrasensitive detection of SARS-CoV-2. The process of the preparation of the sensor layer included chemisorption of cysteamine layer and covalent anchoring of antibody specific for the S1 subunit of the S protein. The source of the voltametric signal was the antibody labeled with the redox probe, which was introduced onto biosensor surface only after the recognition of the virus. This easy-to-handle immunosensor was characterized by a wide analytical range (2.0·10-7 to 0.20 mg·L-1) and low detection limit (8.0·10-8 mg·L-1 ≡ 0.08 pg·mL-1 ≡ 4 virions·μL-1). The utility of the designed device was also evidenced by the detection of SARS-CoV-2 in the clinical samples. Moreover, the main advantage and a huge novelty of the developed device, compared to those already existing, is the moment of generating the analytical signal of the redox probe that appears only after the virus recognition. Thus, our diagnostic innovation may considerably contribute to controlling the COVID-19 pandemic. The as-developed immunosensor may well offer a novel alternative approach for viral detection that could complement or even replace the existing methods.
Collapse
Affiliation(s)
- Agata Kowalczyk
- Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland
| | - Artur Kasprzak
- Faculty of Chemistry, Warsaw University of Technology, Nowakowskiego 3 Str., PL 00-664 Warsaw, Poland
| | - Monika Ruzycka-Ayoush
- Faculty of Pharmacy, Medical University of Warsaw, Banacha 1 Str., PL 02-097 Warsaw, Poland
| | - Edyta Podsiadły
- Department of Pharmaceutical Microbiology, Centre for Preclinical Research, Faculty of Pharmacy, Medical University of Warsaw, Banacha 1B Str., PL 02-097 Warsaw, Poland
| | - Urszula Demkow
- Department of Laboratory Diagnostics and Clinical Immunology of Developmental Age, Medical University of Warsaw, Zwirki i Wigury 63 A Str., PL 02-091 Warsaw, Poland
| | - Ireneusz P Grudzinski
- Faculty of Pharmacy, Medical University of Warsaw, Banacha 1 Str., PL 02-097 Warsaw, Poland
| | - Anna M Nowicka
- Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland
| |
Collapse
|
16
|
Bipedal DNAzyme walker triggered dual-amplification electrochemical platform for ultrasensitive ratiometric biosensing of microRNA-21. Biosens Bioelectron 2022; 220:114879. [DOI: 10.1016/j.bios.2022.114879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 10/23/2022] [Accepted: 11/01/2022] [Indexed: 11/06/2022]
|
17
|
Macovei DG, Irimes MB, Hosu O, Cristea C, Tertis M. Point-of-care electrochemical testing of biomarkers involved in inflammatory and inflammatory-associated medical conditions. Anal Bioanal Chem 2022; 415:1033-1063. [PMID: 36102973 PMCID: PMC9472196 DOI: 10.1007/s00216-022-04320-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 08/31/2022] [Accepted: 09/02/2022] [Indexed: 02/07/2023]
Abstract
Recent years have shown that the diagnosis and monitoring of biomarkers involved in inflammatory-associated medical conditions such as cancer, neurological disorders, viral infections, or daily physical activities offer real benefits in increasing the quality of medical care and patient life quality. In this context, the use of integrated and portable platforms as point-of-care testing devices for biomedical analysis to enable early disease diagnosis and monitoring, which can be successfully used even at the patient's bed, is an emergency nowadays. The development of low-cost, miniaturized, and portable, user-friendly devices that provide an answer in a timely manner, such as electrochemical sensors, is relevant for the elaboration of point-of-care testing devices. This review focuses on the recent progress in bioanalysis of both specific biomarkers and inflammatory-associated biomarkers present in several diseases like neoplasia, severe neurological disorders, viral infections, and usual physical activity and provides an overview of the state of the art over the most recent electrochemical (bio)sensors for the detection of inflammation-related biomarkers. Future perspectives of point-of-care testing to improve healthcare management are also discussed.
Collapse
Affiliation(s)
- Diana-Gabriela Macovei
- Department of Analytical Chemistry, Faculty of Pharmacy, “Iuliu Haţieganu” University of Medicine and Pharmacy, 4 Pasteur Street, 400349 Cluj-Napoca, Romania
| | - Maria-Bianca Irimes
- Department of Analytical Chemistry, Faculty of Pharmacy, “Iuliu Haţieganu” University of Medicine and Pharmacy, 4 Pasteur Street, 400349 Cluj-Napoca, Romania
| | - Oana Hosu
- Department of Analytical Chemistry, Faculty of Pharmacy, “Iuliu Haţieganu” University of Medicine and Pharmacy, 4 Pasteur Street, 400349 Cluj-Napoca, Romania
| | - Cecilia Cristea
- Department of Analytical Chemistry, Faculty of Pharmacy, “Iuliu Haţieganu” University of Medicine and Pharmacy, 4 Pasteur Street, 400349 Cluj-Napoca, Romania
| | - Mihaela Tertis
- Department of Analytical Chemistry, Faculty of Pharmacy, “Iuliu Haţieganu” University of Medicine and Pharmacy, 4 Pasteur Street, 400349 Cluj-Napoca, Romania
| |
Collapse
|
18
|
Liu J, Ma P, Yu H, Wang M, Yin P, Pang S, Jiao Y, Dong T, Liu A. Discovery of a Phage Peptide Specifically Binding to the SARS-CoV-2 Spike S1 Protein for the Sensitive Phage-Based Enzyme-Linked Chemiluminescence Immunoassay of the SARS-CoV-2 Antigen. Anal Chem 2022; 94:11591-11599. [PMID: 35948070 PMCID: PMC9380820 DOI: 10.1021/acs.analchem.2c01988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Accepted: 07/29/2022] [Indexed: 02/06/2023]
Abstract
The COVID-19 pandemic has led to a global crisis with devastating effects on public healthcare and the economy. Sensitive detection of SARS-CoV-2 is the key to diagnose and control its spread. The spike (S) protein is an abundant viral transmembrane protein and a suitable target protein for the selective recognition of SARS-CoV-2. Here, we report that with bovine serum albumin prescreening, a specific phage peptide targeting SARS-CoV-2 S1 protein was biopanned with the pIII phage display library. The identified phage #2 expressing the peptide (amino acid sequence: NFWISPKLAFAL) shows high affinity to the target with a dissociation constant of 3.45 ± 0.58 nM. Furthermore, the identified peptide shows good specificity with a binding site at the N-terminal domain of the S1 subunit through a hydrogen bond network and hydrophobic interaction, supported by molecular docking. Then, a sandwiched phage-based enzyme-linked chemiluminescence immunoassay (ELCLIA) was established by using phage #2 as a bifunctional probe capable of SARS-CoV-2 S1 antigen recognition and signal amplification. After optimizing the conditions, the proposed phage ELCLIA exhibited good sensitivity, and as low as 78 pg/mL SARS-CoV-2 S1 could be detected. This method can be applied to detect as low as 60 transducing units (TU)/mL SARS-CoV-2 pseudovirus in 50% saliva. Therefore, specific phage peptides have good prospects as powerful biological recognition probes for immunoassay detection and biomedical applications.
Collapse
Affiliation(s)
| | | | - Haipeng Yu
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Mingyang Wang
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Pengxue Yin
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Shuang Pang
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Yiming Jiao
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Tao Dong
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| | - Aihua Liu
- Institute for Chemical Biology &
Biosensing, College of Life Sciences, Qingdao
University, 308 Ningxia Road, Qingdao 266071, China
| |
Collapse
|
19
|
Impedimetric Detection Based on Label-Free Immunoassay Developed for Targeting Spike S1 Protein of SARS-CoV-2. Diagnostics (Basel) 2022; 12:diagnostics12081992. [PMID: 36010342 PMCID: PMC9407092 DOI: 10.3390/diagnostics12081992] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 08/01/2022] [Accepted: 08/12/2022] [Indexed: 11/24/2022] Open
Abstract
After the COVID-19 pandemic started all over the world, great importance was placed on the development of sensitive and selective bioanalytical assays for the rapid detection of the highly pathogenic SARS-CoV-2 virus causing COVID-19 disease. In this present work, an impedimetric immunosensor was developed and applied for rapid, reliable, sensitive and selective detection of the SARS-CoV-2 S1 protein. To detect the SARS-CoV-2 virus, targeting of the spike S1 protein was achieved herein by using S1 protein-specific capture antibody (Cab-S1) immobilized screen-printed electrode (SPE) in combination with the electrochemical impedance spectroscopy (EIS) technique. With the impedimetric immunosensor, the detection limit for S1 protein in buffer medium was found to be 0.23 ng/mL (equal to 23.92 amol in 8 µL sample) in the linear concentration range of S1 protein from 0.5 to 10 ng/mL. In the artificial saliva medium, it was found to be 0.09 ng/mL (equals to 9.36 amol in 8 µL sample) in the linear concentration range of S1 protein between 0.1 and 1 ng/mL. The selectivity of the impedimetric immunosensor toward S1 protein was tested against influenza hemagglutinin antigen (HA) in the buffer medium as well as in artificial saliva.
Collapse
|
20
|
Tobik ER, Kitfield-Vernon LB, Thomas RJ, Steel SA, Tan SH, Allicock OM, Choate BL, Akbarzada S, Wyllie AL. Saliva as a sample type for SARS-CoV-2 detection: implementation successes and opportunities around the globe. Expert Rev Mol Diagn 2022; 22:519-535. [PMID: 35763281 DOI: 10.1080/14737159.2022.2094250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Symptomatic testing and asymptomatic screening for SARS-CoV-2 continue to be essential tools for mitigating virus transmission. Though COVID-19 diagnostics initially defaulted to oropharyngeal or nasopharyngeal sampling, the worldwide urgency to expand testing efforts spurred innovative approaches and increased diversity of detection methods. Strengthening innovation and facilitating widespread testing remains critical for global health, especially as additional variants emerge and other mitigation strategies are recalibrated. AREAS COVERED A growing body of evidence reflects the need to expand testing efforts and further investigate the efficiency, sensitivity, and acceptability of saliva samples for SARS-CoV-2 detection. Countries have made pandemic response decisions based on resources, costs, procedures, and regional acceptability - the adoption and integration of saliva-based testing among them. Saliva has demonstrated high sensitivity and specificity while being less invasive relative to nasopharyngeal swabs, securing saliva's position as a more acceptable sample type. EXPERT OPINION Despite the accessibility and utility of saliva sampling, global implementation remains low compared to swab-based approaches. In some cases, countries have validated saliva-based methods but face challenges with testing implementation or expansion. Here, we review the localities that have demonstrated success with saliva-based SARS-CoV-2 testing approaches and can serve as models for transforming concepts into globally-implemented best practices.
Collapse
Affiliation(s)
- Emily R Tobik
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Lily B Kitfield-Vernon
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Russell J Thomas
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Sydney A Steel
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Steph H Tan
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA.,Department of Health Policy and Management, Yale School of Public Health, New Haven, Connecticut, USA
| | - Orchid M Allicock
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Brittany L Choate
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Sumaira Akbarzada
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| | - Anne L Wyllie
- Department of Epidemiology of Microbial Diseases, Yale School of Public Health, New Haven, Connecticut, USA
| |
Collapse
|