1
|
Li H, Li Z, Zhang X, Sun W, Ao X, Li Z. Nitrate Enhanced Sulfamethoxazole Degradation by 222 nm Far-UVC Irradiation: Role of Reactive Nitrogen Species. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:17510-17519. [PMID: 39297779 DOI: 10.1021/acs.est.4c07539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/02/2024]
Abstract
The application of 222 nm far-UVC irradiation for degrading organic micropollutants in water shows promise. Nitrate (NO3-), found in nearly all water bodies, can significantly impact the performance of 222 nm far-UVC-driven systems. This work was the first to investigate the effect of NO3- on sulfamethoxazole (SMX) photodegradation at 222 nm, finding that NO3- significantly enhances SMX degradation in different dissociated forms. Besides the hydroxyl radical (•OH), reactive nitrogen species (RNS) also played important roles in SMX degradation. With increasing NO3- concentration, the RNS contribution to SMX degradation decreased from 25.7 to 8.6% at pH 3 but increased from 1.5 to 24.7% at pH 7, since the deprotonated SMX with electron-rich groups reacted more easily with RNS. The transformation mechanisms of SMX involving isomerization, bond cleavage, hydroxylation, nitrosation, and nitration processes were proposed. 15N isotope labeling experiments showed that the RNS-induced nitrated products even became the major products of SMX in the 222 nm far-UVC/NO3- system at pH 7 and exhibited a higher toxicity than SMX itself. Further research is necessary to avoid or eliminate these toxic byproducts. This study provides valuable insights for guiding the utilization of 222 nm far-UVC for treating antibiotics in NO3--containing water.
Collapse
Affiliation(s)
- Haoxin Li
- School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, International Science and Technology Cooperation Base for Environmental and Energy Technology of MOST, University of Science and Technology Beijing, Beijing 100083, China
| | - Ziyi Li
- School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, International Science and Technology Cooperation Base for Environmental and Energy Technology of MOST, University of Science and Technology Beijing, Beijing 100083, China
| | - Xi Zhang
- School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, International Science and Technology Cooperation Base for Environmental and Energy Technology of MOST, University of Science and Technology Beijing, Beijing 100083, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
| | - Xiuwei Ao
- School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, International Science and Technology Cooperation Base for Environmental and Energy Technology of MOST, University of Science and Technology Beijing, Beijing 100083, China
| | - Zifu Li
- School of Energy and Environmental Engineering, Beijing Key Laboratory of Resource-oriented Treatment of Industrial Pollutants, International Science and Technology Cooperation Base for Environmental and Energy Technology of MOST, University of Science and Technology Beijing, Beijing 100083, China
| |
Collapse
|
2
|
Bai Q, Wu QY, Ye B, Wu YP, Lee JW, Lee MY, Wang WL. Assessing excimer far-UVC (222 nm) irradiation for advanced oxidation processes: Oxidants photochemistry and micropollutants degradation. WATER RESEARCH 2024; 267:122505. [PMID: 39378730 DOI: 10.1016/j.watres.2024.122505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2024] [Revised: 09/15/2024] [Accepted: 09/22/2024] [Indexed: 10/10/2024]
Abstract
The KrCl* excimer lamp (UV222) is a promising alternative of low-pressure mercury lamp (UV254) for UV-based advanced oxidation processes (UV-AOPs), because it is mercury-free and has high photon energy. But there lacks a comprehensive assessment of UV222-AOPs based on different radicals. Herein, the properties (e.g., oxidant decay and innate radical quantum yield), and micropollutant degradation, were comprehensively studied for representative oxidants (i.e., hydrogen peroxide, persulfate (PDS), monochloramine, and free active chlorine (FAC)) under UV222 irradiation. UV222 outperformed UV254 for the activation of oxidants with 2.6-14.4 times fluence-based kinetic constant (kF). The main reason of enhanced activation varied with oxidants: higher UV absorbance for H2O2, higher innate quantum yield for monochloramine and FAC, and both reasons for PDS. Overall, PDS was the optimum oxidant under UV222 for the degradation of 8 representative micropollutants because of effective promotion of radical formation, as confirmed by radical competitive kinetics and modeling simulations. In real water, UV222/PDS still show advantages than UV254/PDS in terms of micropollutant elimination efficacy (3.2-5.3 times) and energy consumption (33.9 %-57.6 % lower) though it was more inhibited by water constituents via competing for UV222 photons. This study fills gaps in photochemistry knowledge and will facilitate engineering practice of UV222-AOPs.
Collapse
Affiliation(s)
- Qing Bai
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Qian-Yuan Wu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Bei Ye
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Yun-Peng Wu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Ju-Won Lee
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China
| | - Min-Yong Lee
- Division of Chemical Research, National Institute of Environmental Research, Incheon 22689, Republic of Korea
| | - Wen-Long Wang
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Guangdong Provincial Engineering Research Center for Urban Water Recycling and Environmental Safety, Shenzhen Key Laboratory of Ecological Remediation and Carbon Sequestration, Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| |
Collapse
|
3
|
Zhao J, Gong W, Yin R, Shang C, Mitch WA. Control of Aromatic Disinfection Byproducts in Potable Reuse Water by the UV 222/H 2O 2 vs UV 254/H 2O 2 Advanced Oxidation Processes. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:15846-15854. [PMID: 39169482 DOI: 10.1021/acs.est.4c05181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/23/2024]
Abstract
Research has demonstrated the difficulty associated with degrading the conventional 1-2 carbon aliphatic halogenated byproducts of disinfectant reactions with organic matter [disinfection byproducts (DBPs)] within advanced oxidation process (AOP) units in potable reuse trains, but the efficacy of AOP units for treating the emerging classes of halogenated aromatic DBPs is unclear. We herein demonstrate more effective removal of 28 halogenated aromatic DBPs in the UV/H2O2 AOP at 222 nm (UV222) than in the conventional UV/H2O2 AOP at 254 nm. Direct photolysis of 28 halogenated aromatic DBPs was greatly enhanced at 222 nm with fluence-based photodecay rate constants of 4.31 × 10-4-1.53 × 10-2 cm2 mJ-1, which was mainly attributed to the higher molar absorption coefficients of halogenated aromatic DBPs at 222 nm than 254 nm. Generally, quantum yields of halogenated aromatic DBPs at both 222 and 254 nm followed the order of halophenols > halohydroxybenzaldehydes > halonitrophenols. All 28 halogenated aromatic DBPs exhibit high reactivity toward HO• with second-order rate constants ranging from 2.18 × 109 to 1.15 × 1010 M-1 s-1 determined by X-ray radiolysis. The UV fluence required to achieve 90% loss of halogenated aromatic DBPs in the UV222/H2O2 AOP was 75-95% lower than that in the UV254/H2O2 AOP, and 90% removal of most tested halogenated aromatic DBPs can be achieved in the UV222/H2O2 AOP within the UV fluence levels commonly applied in potable reuse (700-1000 mJ cm-2).
Collapse
Affiliation(s)
- Jing Zhao
- Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong, China
| | - Weiran Gong
- Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States
| | - Ran Yin
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
- Institute for the Environment and Health, Nanjing University Suzhou Campus, Suzhou 215163, China
| | - Chii Shang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong, China
- Hong Kong Branch of Chinese National Engineering Research Center for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong SAR, China
| | - William A Mitch
- Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States
| |
Collapse
|
4
|
Freitas BLS, Fava NMDN, Melo-Neto MGD, Dalkiranis GG, Tonetti AL, Byrne JA, Fernandez-Ibañez P, Sabogal-Paz LP. Efficacy of UVC-LED radiation in bacterial, viral, and protozoan inactivation: an assessment of the influence of exposure doses and water quality. WATER RESEARCH 2024; 266:122322. [PMID: 39213680 DOI: 10.1016/j.watres.2024.122322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 08/20/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024]
Abstract
Ultraviolet light-emitting diodes (UV-LEDs) have demonstrated the ability to inactivate microorganisms in water, offering an environmentally safer alternative to the conventional mercury lamp, in UV applications. While several studies have explored the microbiological effect of UVC-LEDs (200nm-280nm), limited information exists regarding their effects on waters with critical qualities. These critical qualities encompass bacteria, viruses, and protozoa - drinking water quality indicators defined by the World Health Organization for small water systems. For the first time, this work reports on the Escherichia coli, PhiX-174, MS2, and Cryptosporidium oocysts inactivation using a bench-scale UVC-LED (280 nm) water disinfection system. UV doses at a wavelength of 280 nm (UV280) of up to 143.4 mJ/cm2 were delivered under two quality-critical water conditions: filtered water (UV transmittance at 280 nm - UVT280 90.2 %) and WHO challenge water (UVT 15.7 %). Results revealed microbiological reductions dependent on exposure time and UVT. For UV280 dose of 16.1 mJ/cm2, 2.93-3.70 log E. coli reductions were observed in UVT 90.2 % and 15.7 %, 3.49-4.21 log for PhiX-174, 0.63-0.78 log for MS2, and 0.02-0.04 log for Cryptosporidium oocysts. Significantly higher UV280 doses of 143.4 mJ/cm2 led to reductions of 3.94-5.35 log for MS2 and 0.42-0.46 log for Cryptosporidium oocysts. Statistical analysis revealed that the sensitivity among the organisms to UV280 exposure was E. coli = PhiX-174 > MS2 >> Cryptosporidium oocysts. Although experiments with WHO challenge water posed greater challenges for achieving 1 log reduction compared to filtered water, this difference only proved statistically significant for PhiX-174 and MS2 reductions. Overall, UVC-LED technology demonstrated notable efficacy in microbiological inactivation, achieving significant reductions based on WHO scheme of evaluation for POU technologies in both bacteria and viruses even in critical-quality waters. The findings emphasize the potential for extending the application of UVC-LED as a viable solution for household water treatment.
Collapse
Affiliation(s)
- Bárbara Luíza Souza Freitas
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Natália Melo de Nasser Fava
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Murilo Guilherme de Melo-Neto
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Gustavo Gonçalves Dalkiranis
- São Carlos Institute of Physics, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil
| | - Adriano Luiz Tonetti
- School of Civil Engineering, Architecture and Urbanism - FECFAU, UNICAMP (State University of Campinas), Avenida Albert Einstein, 951, Cidade Universitária "Zeferino Vaz", Campinas, SP, 13083-852, Brazil
| | - John Anthony Byrne
- Nanotechnology and Integrated Bioengineering Centre, School of Engineering, Ulster University, Jordanstown, BT37 0QB, Northern Ireland, United Kingdom
| | - Pilar Fernandez-Ibañez
- Nanotechnology and Integrated Bioengineering Centre, School of Engineering, Ulster University, Jordanstown, BT37 0QB, Northern Ireland, United Kingdom
| | - Lyda Patricia Sabogal-Paz
- Department of Hydraulics and Sanitation, São Carlos School of Engineering, University of São Paulo, Avenida Trabalhador São-Carlense 400, São Carlos, São Paulo, 13566-590, Brazil.
| |
Collapse
|
5
|
Xu J, Kann RJ, Mohammed D, Huang CH. Far-UVC 222 nm Treatment: Effects of Nitrate/Nitrite on Disinfection Byproduct Formation Potential. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58. [PMID: 39133232 PMCID: PMC11360365 DOI: 10.1021/acs.est.4c04258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Revised: 07/29/2024] [Accepted: 07/30/2024] [Indexed: 08/13/2024]
Abstract
Irradiation at far ultraviolet C (far-UVC) 222 nm by krypton chloride (KrCl*) excilamps can enhance microbial disinfection and micropollutant photolysis/oxidation. However, nitrate/nitrite, which absorbs strongly at 222 nm, may affect the formation of disinfection byproducts (DBPs). Herein, we evaluated model organic matter and real water samples and observed a substantial increase in the formation potential for trichloronitromethane (chloropicrin) (TCNM-FP), a nitrogenous DBP, by nitrate or nitrite after irradiation at 222 nm. At a disinfection dose of 100 mJ·cm-2, TCNM-FP of humic acids and fulvic acids increased from ∼0.4 to 25 and 43 μg·L-1, respectively, by the presence of 10 mg-N·L-1 nitrate. For the effect of nitrate concentration, the TCNM-FP peak was observed at 5-10 mg-N·L-1. Stronger fluence caused a greater increase of TCNM-FP. Similarly, the increase of TCNM-FP was also observed for wastewater and drinking water samples containing nitrate. Pretreatment using ozonation and coagulation, flocculation, and filtration or the addition of H2O2 can effectively control TCNM-FP. The formation potential of other DBPs was minorly affected by irradiation at 222 nm regardless of whether nitrate/nitrite was present. Overall, far-UVC 222 nm treatment poses the risk of increasing TCNM-FP of waters containing nitrate or nitrite at environmentally relevant concentrations and the mitigation strategies merit further research.
Collapse
Affiliation(s)
- Jiale Xu
- Department
of Civil, Construction and Environmental Engineering, North Dakota State University, Fargo, North Dakota 58102, United States
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Ryan J. Kann
- School
of Biological Sciences, Georgia Institute
of Technology, Atlanta, Georgia 30332, United States
| | - Dauda Mohammed
- Department
of Civil, Construction and Environmental Engineering, North Dakota State University, Fargo, North Dakota 58102, United States
| | - Ching-Hua Huang
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
6
|
Ma D, Belloni C, Hull NM. Innovative microbial water quality management in water distribution systems using in-pipe hydropowered UV disinfection: envisioning futuristic water-energy systems. ENVIRONMENTAL TECHNOLOGY 2024:1-17. [PMID: 39010788 DOI: 10.1080/09593330.2024.2375008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Accepted: 06/14/2024] [Indexed: 07/17/2024]
Abstract
Hydropower UV disinfection has not been explored as a possible alternative for off-grid disinfection. Hydropowered UV LED technology was developed using off-the-shelf UV-C LEDs and pico - and femto-scale hydro turbine generators and evaluated across point-of-use relevant flow rates. Commercially available UV LED flow through reactors were subjected to microorganism challenge testing with 3 power schemes: wall-plug, hydropower, and hydropower-charged battery. UV LEDs powered by hydropower-charged battery demonstrated similar disinfection as wall-plug powered UV LEDs, achieving 0.5-1.8 MS2 log10 reduction at flow rates 0.5-2.3 L min-1, corresponding to reduction equivalent doses (RED) up to 16 or 30 mJ/cm2 for 254 and 285 nm, respectively. With hydropowered UV LEDs alone, MS2 log10 reduction decreased to <0.3 log10 reduction due to an underperforming and grossly inefficient turbine, with RED of 8 or 18 mJ/cm2 for 254 and 285 nm, respectively. Assessment of existing markets of UV disinfection systems and pico-hydro turbines demonstrated that hydropowered UV systems are already theoretically feasible for scales at point-of-entry (POE) and above. Economic feasibility will improve if turbines and/or UV system efficiencies improve. Prototype hydropower UV LED systems ranged from $145 to 220 depending on the UV LED reactor, and the battery system added $81. This study demonstrates the practicality of sustainable, renewable energy POU UV disinfection technology that can benefit decentralised, off-grid, rural and remote communities. The system may also scale up to provide renewable energy disinfection at larger scales, such as buildings and water distribution systems, for protecting human health in highly populated areas.
Collapse
Affiliation(s)
- Daniel Ma
- Department of Civil, Environmental and Geodetic Engineering, The Ohio State University, Columbus, OH, USA
| | - Clarissa Belloni
- Department of Mechanical Engineering, The Ohio State University, Columbus, OH, USA
| | - Natalie M Hull
- Department of Civil, Environmental and Geodetic Engineering, The Ohio State University, Columbus, OH, USA
- The Sustainability Institute, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
7
|
Monika, Madugula SK, Kondabagil K, Kunwar A. Far-UVC (222 nm) irradiation effectively inactivates ssRNA, dsRNA, ssDNA, and dsDNA viruses as compared to germicidal UVC (254 nm). Photochem Photobiol 2024. [PMID: 38736273 DOI: 10.1111/php.13961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/23/2024] [Accepted: 04/24/2024] [Indexed: 05/14/2024]
Abstract
Ultraviolet-C (UVC) irradiation is being used as an effective approach for the disinfection of pathogenic viruses present in air, surfaces, and water. Recently, far-UVC radiation (222 nm) emitted by KrCl* (krypton-chloride) excimer lamps have been recommended for disinfecting high-risk public spaces to reduce the presence and transmission of infectious viruses owing to limited human health exposure risks as compared to germicidal UVC (254 nm). In this study, the UVC inactivation performances of individual filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were determined against four viruses, bacteriophages MS2, Phi6, M13, and T4, having different genome compositions (ssRNA, dsRNA, ssDNA and dsDNA, respectively) and shapes (i.e., spherical (Phi6), linear (M13), and icosahedral (MS2 and T4)). Here, the disinfection efficacies of filtered KrCl* excimer lamp (222 nm) and germicidal UVC lamp (254 nm) were evaluated for highly concentrated virus droplets that mimic the virus-laden droplets released from the infected person and deposited on surfaces as fomites. Filtered KrCl* excimer (222 nm) showed significantly better inactivation against all viruses having different genome compositions and structures compared to germicidal UVC (254 nm). The obtained sensitivity against the filtered KrCl* excimer (222 nm) was found to be in the order, T4 > M13 > Phi6 > MS2 whereas for the germicidal UVC (254 nm) it was T4 > M13 > MS2 > Phi6. These results provide a strong basis to promote the use of filtered KrCl* excimer lamps (222 nm) in disinfecting contagious viruses and to limit the associated disease spread in public places and other high-risk areas.
Collapse
Affiliation(s)
- Monika
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Santhosh Kumar Madugula
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Kiran Kondabagil
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| | - Ambarish Kunwar
- Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
- Koita Centre for Digital Health (KCDH), Indian Institute of Technology Bombay, Mumbai, Maharashtra, India
| |
Collapse
|
8
|
Lu YH, Wang RX, Liu HL, Lai ACK. Evaluating the Performance of UV Disinfection across the 222-365 nm Spectrum against Aerosolized Bacteria and Viruses. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6868-6877. [PMID: 38593035 DOI: 10.1021/acs.est.3c08675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
Bioaerosols play a significant role in the transmission of many infectious diseases, especially in enclosed indoor environments. Ultraviolet (UV) disinfection has demonstrated a high efficacy in inactivating microorganisms suspended in the air. To develop more effective and efficient UV disinfection protocols, it is necessary to evaluate and optimize the effectiveness of UV disinfection against aerosolized bacteria and viruses across the entire UV spectrum. In this study, we evaluated the performance of UV disinfection across the UV spectrum, ranging from 222 to 365 nm, against aerosolized bacteria and viruses, including Escherichia coli, Staphylococcus epidermidis, Salmonella enterica, MS2, P22, and Phi6. Six commonly available UV sources, including gas discharge tubes and light-emitting diodes with different emission spectra, were utilized, and their performance in terms of inactivation efficacy, action spectrum, and energy efficiency was determined. Among these UV sources, the krypton chloride excilamp emitting at a peak wavelength of 222 nm was the most efficient in inactivating viral bioaerosols. A low-pressure mercury lamp emitting at 254 nm performed well on both inactivation efficacy and energy efficiency. A UV light-emitting diode emitting at 268 nm demonstrated the highest bacterial inactivation efficacy, but required approximately 10 times more energy to achieve an equivalent inactivation level compared with that of the krypton chloride excilamp and low-pressure mercury lamp. This study provides insights into UV inactivation on bioaerosols, which can guide the development of effective wavelength-targeted UV air disinfection technologies and may significantly help reduce bioaerosol transmission in public areas.
Collapse
Affiliation(s)
- Y H Lu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - R X Wang
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - H L Liu
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| | - A C K Lai
- School of Energy and Environment, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong
| |
Collapse
|
9
|
Laauwen M, Nowicki S. Reinforcing Feedbacks for Sustainable Implementation of Rural Drinking-Water Treatment Technology. ACS ES&T WATER 2024; 4:1763-1774. [PMID: 38633363 PMCID: PMC11019543 DOI: 10.1021/acsestwater.3c00779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 02/09/2024] [Accepted: 03/06/2024] [Indexed: 04/19/2024]
Abstract
Progress toward universal access to safe drinking water depends on rural water service delivery models that incorporate water safety management. Water supplies of all types have high rates of fecal contamination unless water safety risks are actively managed through water source protection, treatment, distribution, and storage. Recognizing the role of treatment within this broader risk-based framework, this study focuses on the implementation of passive chlorination and ultraviolet (UV) disinfection technologies in rural settings. These technologies can reduce the health risk from microbiological contaminants in drinking water; however, technology-focused treatment interventions have had limited sustainability in rural settings. This study examines the requirements for sustainable implementation of rural water treatment through qualitative content analysis of 26 key informant interviews, representing passive chlorination and UV disinfection projects in rural areas in South America, Africa, and Asia. The analysis is aligned with the RE-AIM framework and delivers insight into 18 principal enablers and barriers to rural water treatment sustainability. Analysis of the interrelationships among these factors identifies leverage points and encourages fit-for-purpose intervention design reinforced by collaboration between facilitating actors through hybrid service delivery models. Further work should prioritize health impact evidence, water quality reporting guidance, and technological capabilities that optimize trade-offs in fit-for-purpose treatment design.
Collapse
Affiliation(s)
- Merel Laauwen
- School
of Geography and the Environment, University
of Oxford, South Parks Road, Oxford OX1 3QY, U.K.
| | - Saskia Nowicki
- School
of Geography and the Environment, University
of Oxford, South Parks Road, Oxford OX1 3QY, U.K.
| |
Collapse
|
10
|
Yin R, Zhang Y, Wang Y, Zhao J, Shang C. Far-UVC Photolysis of Peroxydisulfate for Micropollutant Degradation in Water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:6030-6038. [PMID: 38517061 DOI: 10.1021/acs.est.3c09120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
Increasing radical yields to reduce UV fluence requirement for achieving targeted removal of micropollutants in water would make UV-based advanced oxidation processes (AOPs) less energy demanding in the context of United Nations' Sustainable Development Goals and carbon neutrality. We herein demonstrate that, by switching the UV radiation source from conventional low-pressure UV at 254 nm (UV254) to emerging Far-UVC at 222 nm (UV222), the fluence-based concentration of HO• in the UV/peroxydisulfate (UV/PDS) AOP increases by 6.40, 2.89, and 6.00 times in deionized water, tap water, and surface water, respectively, with increases in the fluence-based concentration of SO4•- also by 5.06, 5.81, and 55.47 times, respectively. The enhancement to radical generation is confirmed using a kinetic model. The pseudo-first-order degradation rate constants of 16 micropollutants by the UV222/PDS AOP in surface water are predicted to be 1.94-13.71 times higher than those by the UV254/PDS AOP. Among the tested water matrix components, chloride and nitrate decrease SO4•- but increase HO• concentration in the UV222/PDS AOP. Compared to the UV254/PDS AOP, the UV222/PDS AOP decreases the formation potentials of carbonaceous disinfection byproducts (DBPs) but increases the formation potentials of nitrogenous DBPs.
Collapse
Affiliation(s)
- Ran Yin
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
- Institute for the Environment and Health, Nanjing University Suzhou Campus, Suzhou 215163, China
| | - Yuliang Zhang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Yongyi Wang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Jing Zhao
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Chii Shang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
- Hong Kong Branch of Chinese National Engineering Research Center for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| |
Collapse
|
11
|
Rufyikiri AS, Martinez R, Addo PW, Wu BS, Yousefi M, Malo D, Orsat V, Vidal SM, Fritz JH, MacPherson S, Lefsrud M. Germicidal efficacy of continuous and pulsed ultraviolet-C radiation on pathogen models and SARS-CoV-2. Photochem Photobiol Sci 2024; 23:339-354. [PMID: 38308169 DOI: 10.1007/s43630-023-00521-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 12/12/2023] [Indexed: 02/04/2024]
Abstract
Ultraviolet radiation's germicidal efficacy depends on several parameters, including wavelength, radiant exposure, microbial physiology, biological matrices, and surfaces. In this work, several ultraviolet radiation sources (a low-pressure mercury lamp, a KrCl excimer, and four UV LEDs) emitting continuous or pulsed irradiation were compared. The greatest log reductions in E. coli cells and B. subtilis endospores were 4.1 ± 0.2 (18 mJ cm-2) and 4.5 ± 0.1 (42 mJ cm-2) with continuous 222 nm, respectively. The highest MS2 log reduction observed was 2.7 ± 0.1 (277 nm at 3809 mJ cm-2). Log reductions of SARS-CoV-2 with continuous 222 nm and 277 nm were ≥ 3.4 ± 0.7, with 13.3 mJ cm-2 and 60 mJ cm-2, respectively. There was no statistical difference between continuous and pulsed irradiation (0.83-16.7% [222 nm and 277 nm] or 0.83-20% [280 nm] duty rates) on E. coli inactivation. Pulsed 260 nm radiation (0.5% duty rate) at 260 nm yielded significantly greater log reduction for both bacteria than continuous 260 nm radiation. There was no statistical difference in SARS-CoV-2 inactivation between continuous and pulsed 222 nm UV-C radiation and pulsed 277 nm radiation demonstrated greater germicidal efficacy than continuous 277 nm radiation. Greater radiant exposure for all radiation sources was required to inactivate MS2 bacteriophage. Findings demonstrate that pulsed irradiation could be more useful than continuous UV radiation in human-occupied spaces, but threshold limit values should be respected. Pathogen-specific sensitivities, experimental setup, and quantification methods for determining germicidal efficacy remain important factors when optimizing ultraviolet radiation for surface decontamination or other applications.
Collapse
Affiliation(s)
- Anne Sophie Rufyikiri
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Rebecca Martinez
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Philip W Addo
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Bo-Sen Wu
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Mitra Yousefi
- Dahdaleh Institute of Genomic Medicine and McGill University Research Centre on Complex Traits, Life Sciences Complex, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
| | - Danielle Malo
- Dahdaleh Institute of Genomic Medicine and McGill University Research Centre on Complex Traits, Life Sciences Complex, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
- Department of Medicine, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
- Department of Human Genetics, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
| | - Valérie Orsat
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Silvia M Vidal
- Dahdaleh Institute of Genomic Medicine and McGill University Research Centre on Complex Traits, Life Sciences Complex, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
- Department of Human Genetics, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
- Department of Microbiology and Immunology, McGill University, 3775 Rue University, Montreal, QC, H3A 2B4, Canada
| | - Jörg H Fritz
- Dahdaleh Institute of Genomic Medicine and McGill University Research Centre on Complex Traits, Life Sciences Complex, McGill University, 3649 Promenade Sir William Osler, Montreal, QC, H3G 0B1, Canada
- Department of Microbiology and Immunology, McGill University, 3775 Rue University, Montreal, QC, H3A 2B4, Canada
| | - Sarah MacPherson
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada
| | - Mark Lefsrud
- Department of Bioresource Engineering, Macdonald Campus, McGill University, 21111 Lakeshore Road, Sainte-Anne-de-Bellevue, QC, H9X 3V9, Canada.
| |
Collapse
|
12
|
Li YQ, Sun R, Zhang CM, Liu ZX, Chen RT, Zhao J, Gu HD, Yin HC. Inactivation of pathogenic microorganisms in water by electron beam excitation multi-wavelength ultraviolet irradiation: Efficiency, influence factors and mechanism. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 350:119597. [PMID: 38029495 DOI: 10.1016/j.jenvman.2023.119597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 10/27/2023] [Accepted: 11/10/2023] [Indexed: 12/01/2023]
Abstract
Due to the limitations of traditional ultraviolet (UV) in microbial inactivation in water, it is necessary to explore a more suitable and efficient UV disinfection method. In this study, an electron beam excitation multi-wavelength ultraviolet (EBE-MW-UV) system was established and aims to analyze its differential microbial inactivation capabilities in comparison to single-wavelength UV-LEDs in waterborne applications. Furthermore, the inactivation mechanisms of this system on microorganisms were explored. The results showed that EBE-MW-UV had significantly higher inactivation effects on the Escherichia coli, Pseudomonas aeruginosa, Bacillus subtilis and Candida albicans in water compared to UV-LEDs (p<0.05), and the inactivation effect of EBE-MW-UV on Escherichia coli and Pseudomonas aeruginosa at the same UV dose was 3.8 and 1.9 log higher than that of UV-LEDs, respectively, EBE-MW-UV exhibited better inactivation effects on Gram-negative bacteria. Further research found that, under the majority of irradiation doses, neither EBE-MW-UV nor UV-LEDs were significantly affected by the concentration of suspended solids (5 and 20 mg/L) or humic acids (2 and 5 mg/L) in the water. Mechanism analysis revealed that during the disinfection process of EBE-MW-UV, microbial DNA and proteins were initially damaged, which prevented the occurrence of dark repair and led to bacterial inactivation. In addition, UV irradiation led to the production of additional reactive oxygen species (ROS) inside the cells, increasing cell membrane permeability and exacerbating membrane damage. This was accompanied by a decrease in energy metabolism and depletion of ATP, ultimately resulting in microbial inactivation. Therefore, EBE-MW-UV demonstrated more effective disinfection than single-wavelength UV-LEDs, showing great potential. Our research gives new insights into the characteristics of multiple wavelength ultraviolet, and provides scientific basis for the selection of new light sources in the field of ultraviolet disinfection.
Collapse
Affiliation(s)
- Yong-Qiang Li
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Rui Sun
- School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei 230026, China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Chong-Miao Zhang
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; International Science and Technology Cooperation Center for Urban Alternative Water Resources Development, Xi'an University of Architecture and Technology, Xi'an 710055, China.
| | - Zi-Xuan Liu
- School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China; Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China; Key Lab of Northwest Water Resource, Environment and Ecology, Ministry of Education, Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
| | - Rui-Tao Chen
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Jian Zhao
- Shanghai NovelUv Optoelectronics Technology Co., Ltd, Shanghai 200000, China
| | - Hua-Dong Gu
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Huan-Cai Yin
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
| |
Collapse
|
13
|
Wang Y, Ma B, Zhao J, Tang Z, Li W, He C, Xia D, Linden KG, Yin R. Rapid Inactivation of Fungal Spores in Drinking Water by Far-UVC Photolysis of Free Chlorine. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:21876-21887. [PMID: 37978925 DOI: 10.1021/acs.est.3c05703] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
Effective and affordable disinfection technology is one key to achieving Sustainable Development Goal 6. In this work, we develop a process by integrating Far-UVC irradiation at 222 nm with free chlorine (UV222/chlorine) for rapid inactivation of the chlorine-resistant and opportunistic Aspergillus niger spores in drinking water. The UV222/chlorine process achieves a 5.0-log inactivation of the A. niger spores at a chlorine dosage of 3.0 mg L-1 and a UV fluence of 30 mJ cm-2 in deionized water, tap water, and surface water. The inactivation rate constant of the spores by the UV222/chlorine process is 0.55 min-1, which is 4.6-fold, 5.5-fold, and 1.8-fold, respectively, higher than those of the UV222 alone, chlorination alone, and the conventional UV254/chlorine process under comparable conditions. The more efficient inactivation by the UV222/chlorine process is mainly attributed to the enhanced generation of reactive chlorine species (e.g., 6.7 × 10-15 M of Cl•) instead of hydroxyl radicals from UV222 photolysis of chlorine, which is verified through both experiments and a kinetic model. We further demonstrate that UV222 photolysis damages the membrane integrity and benefits the penetration of chlorine and radicals into cells for inactivation. The merits of the UV222/chlorine process over the UV254/chlorine process also include the more effective inhibition of the photoreactivation of the spores after disinfection and the lower formation of chlorinated disinfection byproducts and toxicity.
Collapse
Affiliation(s)
- Yongyi Wang
- School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong
| | - Ben Ma
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, Boulder, Colorado 80303, United States
| | - Jing Zhao
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong
| | - Zhuoyun Tang
- School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Wanxin Li
- Department of Health and Environmental Sciences, Xi'an Jiaotong-Liverpool University, Suzhou 215000, China
| | - Chun He
- School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Dehua Xia
- School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou 510275, China
| | - Karl G Linden
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, Boulder, Colorado 80303, United States
| | - Ran Yin
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon 999077, Hong Kong
| |
Collapse
|
14
|
Uppinakudru AP, Martín-Sómer M, Reynolds K, Stanley S, Bautista LF, Pablos C, Marugán J. Wavelength synergistic effects in continuous flow-through water disinfection systems. WATER RESEARCH X 2023; 21:100208. [PMID: 38098879 PMCID: PMC10719571 DOI: 10.1016/j.wroa.2023.100208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/16/2023] [Accepted: 11/17/2023] [Indexed: 12/17/2023]
Abstract
The past decade's development of UV LEDs has fueled significant research in water disinfection, with widespread debate surrounding the potential synergies of multiple UV wavelengths. This study analyses the use of three UV sources (265, 275, and 310 nm) on the inactivation of Escherichia coli bacteria in two water matrixes. At maximum intensity in wastewater, individual inactivation experiments in a single pass set-up (Flow rate = 2 L min-1, Residence time = 0.75 s) confirmed the 265 nm light source to be the most effective (2.2 ± 0.2 log units), while the 310 nm led to the lowest inactivation rate (0.0003 ± 7.03× 10-5 log units). When a combination of the three wavelengths was used, an average log reduction of 4.4 ± 0.2 was observed in wastewater. For combinations of 265 and 275 nm, the average log reductions were similar to the sum of individual log reductions. For combinations involving the use of 310 nm, a potential synergistic effect was investigated by the use of robust statistical analysis techniques. It is concluded that combinations of 310 nm with 265 nm or 275 nm devices, in sequential and simultaneous mode, present a significant synergy at both intensities due to the emission spectra of the selected LEDs, ensuring the possibility of two inactivation mechanisms. Finally, the electrical energy per order of inactivation found the three-wavelength combination to be the most energy efficient (0.39 ± 0.05, 0.36 ± 0.01 kWh m-3, at 50% and 100% dose, respectively, in wastewater) among the synergistic combinations.
Collapse
Affiliation(s)
- Adithya Pai Uppinakudru
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Miguel Martín-Sómer
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Ken Reynolds
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Simon Stanley
- ProPhotonix IRL LTD, 3020 Euro Business Park, Little Island, Cork, T45×211, Ireland
| | - Luis Fernando Bautista
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Cristina Pablos
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| | - Javier Marugán
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán S/n, 28933, Mostoles, Madrid, Spain
| |
Collapse
|
15
|
Zhao J, Shang C, Yin R. A High-Radical-Yield Advanced Oxidation Process Coupling Far-UVC Radiation with Chlorinated Cyanurates for Micropollutant Degradation in Water. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18867-18876. [PMID: 37158565 DOI: 10.1021/acs.est.3c00255] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Increasing the radical yield and reducing energy consumption would enhance the sustainability and competitiveness of advanced oxidation processes (AOPs) for micropollutant degradation in water. We herein report a novel AOP coupling far-UVC radiation at 222 nm with chlorinated cyanurates (termed the UV222/Cl-cyanurates AOP) for radical generation and micropollutant abatement in water. We experimentally determined the concentrations of HO•, Cl•, and ClO• in the UV222/Cl-cyanurates AOP in deionized water and swimming pool water. The radical concentrations are 10-27 times and 4-13 times, respectively, higher than those in the UV254/Cl-cyanurates AOP and the well-documented UV254/chlorine AOP under comparable conditions (e.g., same UV fluence and oxidant dosing). We determined the molar absorption coefficients and innate quantum yields of two chlorine species and two Cl-cyanurates at 222 nm and incorporated these parameters into a kinetic model. The model enables accurate prediction of oxidant photodecay rates as well as the pH impact on radical generation in the UV222/Cl-cyanurates AOP. We predicted the pseudo-first-order degradation rate constants of 25 micropollutants in the UV222/Cl-cyanurates AOP and demonstrated that many micropollutants can be degraded by >80% with a low UV fluence of 25 mJ cm-2. This work advances the fundamental photochemistry of chlorine and Cl-cyanurates at 222 nm and offers a highly effective engineering tool in combating micropollutants in water where Cl-cyanurates are suitable to use.
Collapse
Affiliation(s)
- Jing Zhao
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, P. R. China
| | - Chii Shang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, P. R. China
- Hong Kong Branch of Chinese National Engineering Research Center for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, P. R. China
| | - Ran Yin
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, P. R. China
| |
Collapse
|
16
|
Sun W, Jing Z, Zhao Z, Yin R, Santoro D, Mao T, Lu Z. Dose-Response Behavior of Pathogens and Surrogate Microorganisms across the Ultraviolet-C Spectrum: Inactivation Efficiencies, Action Spectra, and Mechanisms. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:10891-10900. [PMID: 37343195 DOI: 10.1021/acs.est.3c00518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/23/2023]
Abstract
The dose-response behavior of pathogens and inactivation mechanisms by UV-LEDs and excimer lamps remains unclear. This study used low-pressure (LP) UV lamps, UV-LEDs with different peak wavelengths, and a 222 nm krypton chlorine (KrCl) excimer lamp to inactivate six microorganisms and to investigate their UV sensitivities and electrical energy efficiencies. The 265 nm UV-LED had the highest inactivation rates (0.47-0.61 cm2/mJ) for all tested bacteria. The bacterial sensitivity strongly fitted the absorption curve of nucleic acids at wavelengths of 200-300 nm; however, indirect damage induced by reactive oxygen species (ROS) was the leading cause of bacterial inactivation under 222 nm UV irradiation. In addition, the guanine and cytosine (GC) content and cell wall constituents of bacteria affect inactivation efficiency. The inactivation rate constant of Phi6 (0.13 ± 0.002 cm2/mJ) at 222 nm due to lipid envelope damage was significantly higher than other UVC (0.006-0.035 cm2/mJ). To achieve 2log reduction, the LP UV lamp had the best electrical energy efficiency (required less energy, average 0.02 kWh/m3) followed by 222 nm KrCl excimer lamp (0.14 kWh/m3) and 285 nm UV-LED (0.49 kWh/m3).
Collapse
Affiliation(s)
- Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
| | - Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Zhinan Zhao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Ran Yin
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong 999066, PR China
| | | | - Ted Mao
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
- MW Technologies, Inc., London, Ontario L8N1E, Canada
| | - Zedong Lu
- School of Environment, Tsinghua University, Beijing 100084, China
| |
Collapse
|
17
|
Xu J, Huang CH. Enhanced Direct Photolysis of Organic Micropollutants by Far-UVC Light at 222 nm from KrCl* Excilamps. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2023; 10:543-548. [PMID: 37333939 PMCID: PMC10269434 DOI: 10.1021/acs.estlett.3c00313] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 05/24/2023] [Accepted: 05/24/2023] [Indexed: 06/20/2023]
Abstract
Krypton chloride (KrCl*) excilamps emitting at far-UVC 222 nm represent a promising technology for microbial disinfection and advanced oxidation of organic micropollutants (OMPs) in water treatment. However, direct photolysis rates and photochemical properties at 222 nm are largely unknown for common OMPs. In this study, we evaluated photolysis for 46 OMPs by a KrCl* excilamp and compared it with a low-pressure mercury UV lamp. Generally, OMP photolysis was greatly enhanced at 222 nm with fluence rate-normalized rate constants of 0.2-21.6 cm2·μEinstein-1, regardless of whether they feature higher or lower absorbance at 222 nm than at 254 nm. The photolysis rate constants and quantum yields were 10-100 and 1.1-47 times higher, respectively, than those at 254 nm for most OMPs. The enhanced photolysis at 222 nm was mainly caused by strong light absorbance for non-nitrogenous, aniline-like, and triazine OMPs, while notably higher quantum yield (4-47 times of that at 254 nm) occurred for nitrogenous OMPs. At 222 nm, humic acid can inhibit OMP photolysis by light screening and potentially by quenching intermediates, while nitrate/nitrite may contribute more than others to screen light. Overall, KrCl* excilamps are promising in achieving effective OMP photolysis and merit further research.
Collapse
Affiliation(s)
- Jiale Xu
- Department
of Civil, Construction and Environmental Engineering, North Dakota State University, Fargo, North Dakota 58102, United States
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Ching-Hua Huang
- School
of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
18
|
Zhao J, Payne EM, Liu B, Shang C, Blatchley ER, Mitch WA, Yin R. Making waves: Opportunities and challenges of applying far-UVC radiation in controlling micropollutants in water. WATER RESEARCH 2023; 241:120169. [PMID: 37290191 DOI: 10.1016/j.watres.2023.120169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 05/27/2023] [Accepted: 06/02/2023] [Indexed: 06/10/2023]
Abstract
Concerns over human health risks associated with chemical contaminants (micropollutants) in drinking waters are rising due to the increased use of reclaimed water or water supplies impacted by upstream wastewater discharges. Ultraviolet (UV)-driven advanced oxidation processes (UV-AOPs) using radiation sources that emit at 254 nm have been developed as advanced treatments to degrade contaminants, while those UV-AOPs can be improved towards higher radical yields and lower byproduct formation. Several previous studies have suggested that Far-UVC radiation (200-230 nm) is a promising radiance source to drive UV-AOPs because the direct photolysis of micropollutants and production of reactive species from oxidant precursors can both be improved. In this study, we summarize from the literature the photodecay rate constants of five micropollutants by direct UV photolysis, which are higher at 222 than 254 nm. We experimentally determine the molar absorption coefficients at 222 and 254 nm of eight oxidants commonly used in water treatment and present the quantum yields of the oxidant photodecay. Our experimental results also show that the concentrations of HO·, Cl·, and ClO· generated in the UV/chlorine AOP can be increased by 5.15-, 15.76-, and 2.86-fold, respectively, by switching the UV wavelength from 254 to 222 nm. We also point out the challenges of applying Far-UVC for micropollutant abatement in water treatment, including the strong light screening effect of matrix components (e.g., carbonate, nitrate, bromide, and dissolved organic matter), the formation of byproducts via new reaction pathways, and the needs to improve the energy efficiency of the Far-UVC radiation sources.
Collapse
Affiliation(s)
- Jing Zhao
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Emma M Payne
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Drive, Boulder, CO 80303, United States
| | - Bryan Liu
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Drive, Boulder, CO 80303, United States
| | - Chii Shang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong; Hong Kong Branch of Chinese National Engineering Research Center for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| | - Ernest R Blatchley
- Lyles School of Civil Engineering, Purdue University, West Lafayette, IN 47907, United States; Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN 47907, United States
| | - William A Mitch
- Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, CA 94305, United States
| | - Ran Yin
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| |
Collapse
|
19
|
Martín-Sómer M, Pablos C, Adán C, van Grieken R, Marugán J. A review on led technology in water photodisinfection. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 885:163963. [PMID: 37149196 DOI: 10.1016/j.scitotenv.2023.163963] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 04/19/2023] [Accepted: 05/01/2023] [Indexed: 05/08/2023]
Abstract
The increase in efficiency achieved by UV LED devices has led to a compelling increase in research reports on UV LED water treatment for consumption in the past few years. This paper presents an in-depth review based on recent studies on the suitability and performance of UV LED-driven processes for water disinfection. The effect of different UV wavelengths and their combinations was analysed for the inactivation of various microorganisms and the inhibition of repair mechanisms. Whereas 265 nm UVC LED present a higher DNA damaging potential, 280 nm radiation is reported to repress photoreactivation and dark repair. No synergistic effects have been proved to exist when coupling UVB + UVC whereas sequential UVA-UVC radiation seemed to enhance inactivation. Benefits of pulsed over continuous radiation in terms of germicidal effects and energy consumption were also analysed, but with inconclusive results. However, pulsed radiation may be promising for improving thermal management. As a challenge, the use of UV LED sources introduces significant inhomogeneities in the light distribution, pushing for the development of adequate simulation methods to ensure that the minimum target dose required for the target microbes is achieved. Concerning energy consumption, selecting the optimal wavelength of the UV LED needs a compromise between the quantum efficiency of the process and the electricity-to-photon conversion. The expected development of the UV LED industry in the next few years points to UVC LED as a promising technology for water disinfection at a large scale that could be competitive in the market in the near future.
Collapse
Affiliation(s)
- Miguel Martín-Sómer
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán s/n, 28933 Móstoles, Madrid, Spain
| | - Cristina Pablos
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán s/n, 28933 Móstoles, Madrid, Spain
| | - Cristina Adán
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán s/n, 28933 Móstoles, Madrid, Spain
| | - Rafael van Grieken
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán s/n, 28933 Móstoles, Madrid, Spain
| | - Javier Marugán
- Department of Chemical and Environmental Technology, ESCET, Universidad Rey Juan Carlos, C/ Tulipán s/n, 28933 Móstoles, Madrid, Spain.
| |
Collapse
|
20
|
Itani N, El Fadel M. Microbial inactivation kinetics of UV LEDs and effect of operating conditions: A methodological critical analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 885:163727. [PMID: 37120022 DOI: 10.1016/j.scitotenv.2023.163727] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/10/2023]
Abstract
Tiny ultraviolet (UV) light-emitting diodes (LED)s that are replacing the conventional energy-intensive mercury UV lamps have gained interest since the early 2000's because of their promising advantages. In the context of microbial inactivation (MI) of waterborne microbes, disinfection kinetics of those LEDs exhibited variations among studies, in terms of varying the UV wavelength, the exposure time, power, and dose (UV fluence) as well as other operational conditions. While reported results may appear contradictory when examined separately, they probably are not when analyzed collectively. As such, in this study, we carry out a quantitative collective regression analysis of the reported data to shed light on the kinetics of MI by the emerging UV LEDs technology alongside the effects of varying operational conditions. The main goal is to identify dose response requirements for UV LEDs and to compare them to traditional UV lamps in addition to ascertaining optimal settings that could help in achieving the optimal inactivation outcome for comparable UV doses. The analysis showed that kinetically, UV LEDs are as effective as conventional mercury lamps for water disinfection, and at times more effective, especially for UV resistant microbes. We defined the maximal efficiency at two wavelengths, 260-265 nm and 280 nm, among a wide range of available LED wavelengths. We also defined the UV fluence per log inactivation of tested microbes. At the operational level, we identified existing gaps and developed a framework for a comprehensive analysis program for future needs.
Collapse
Affiliation(s)
- N Itani
- Department of Civil Infrastructure and Environmental Engineering, Khalifa University, United Arab Emirates; Department of Civil and Environmental Engineering, American University of Beirut, Lebanon
| | - M El Fadel
- Department of Civil Infrastructure and Environmental Engineering, Khalifa University, United Arab Emirates; Department of Civil and Environmental Engineering, American University of Beirut, Lebanon.
| |
Collapse
|
21
|
Lu YH, Wu H, Zhang HH, Li WS, Lai ACK. Synergistic disinfection of aerosolized bacteria and bacteriophage by far-UVC (222-nm) and negative air ions. JOURNAL OF HAZARDOUS MATERIALS 2023; 441:129876. [PMID: 36087531 DOI: 10.1016/j.jhazmat.2022.129876] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/22/2022] [Accepted: 08/28/2022] [Indexed: 06/15/2023]
Abstract
Air ionizers and 222-nm krypton-chlorine (KrCl) excilamp have proven to be effective disinfection apparatus for bacteria and viruses with limited health risks. We determined inactivation efficiencies by operating them individually and in combined modules. Gram-positive and gram-negative bacteria, non-enveloped dsDNA virus, and enveloped dsRNA virus were examined in a designed air disinfection system. Our results showed that the bioaerosols were inactivated efficiently by negative ionizers and far-UVC (222-nm), either used individually or in combination. Among which the combined modules of negative ionizers and KrCl excilamp had the best disinfection performance for the bacteria. The aerosolized virus P22 and Phi 6 were more susceptible to 222-nm emitted by KrCl excilamp than negative air ions. Significant greater inactivation of bacterial bioaerosols were identified after treated by combined treatment of negative air ion and far-UVC for 2 minutes (Escherichia coli, 6.25 natural log (ln) reduction; Staphylococcus epidermidis, 3.66 ln reduction), as compared to the mean sum value of inactivation results by respective individual treatment of negative ionizers and KrCl excilamp (Escherichia coli, 4.34 ln; Staphylococcus epidermidis, 1.75 ln), indicating a synergistic inactivation effect. The findings provide important baseline data to support the design and development of safe and high-efficient disinfection systems.
Collapse
Affiliation(s)
- Y H Lu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - H Wu
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China; Department of Biology, Hong Kong Baptist University, Kowloon, Hong Kong China
| | - H H Zhang
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China
| | - W S Li
- School of Public Health, The University of Hong Kong, Pokfulam, Hong Kong China
| | - A C K Lai
- Department of Architecture and Civil Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong China.
| |
Collapse
|
22
|
Ratliff K, Oudejans L, Calfee W, Abdel-Hady A, Monge M, Aslett D. Evaluating the impact of ultraviolet C exposure conditions on coliphage MS2 inactivation on surfaces. Lett Appl Microbiol 2022; 75:933-941. [PMID: 35704393 PMCID: PMC9764853 DOI: 10.1111/lam.13770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/09/2022] [Accepted: 06/10/2022] [Indexed: 11/29/2022]
Abstract
The COVID-19 pandemic has raised interest in using devices that generate ultraviolet C (UVC) radiation as an alternative approach for reducing or eliminating microorganisms on surfaces. Studies investigating the efficacy of UVC radiation against pathogens use a wide range of laboratory methods and experimental conditions that can make cross-comparison of results and extrapolation of findings to real-world settings difficult. Here, we use three different UVC-generating sources - a broad-spectrum pulsed xenon light, a continuous light-emitting diode (LED), and a low-pressure mercury vapour lamp - to evaluate the impact of different experimental conditions on UVC efficacy against the coliphage MS2 on surfaces. We find that a nonlinear dose-response relationship exists for all three light sources, meaning that linear extrapolation of doses resulting in a 1-log10 (90%) reduction does not accurately predict the dose required for higher (e.g. 3-log10 or 99.9%) log10 reductions. In addition, our results show that the inoculum characteristics and underlying substrate play an important role in determining UVC efficacy. Variations in microscopic surface topography may shield MS2 from UVC radiation to different degrees, which impacts UVC device efficacy. These findings are important to consider in comparing results from different UVC studies and in estimating device performance in field conditions.
Collapse
Affiliation(s)
- K Ratliff
- Center for Environmental Solutions and Emergency Response, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC, USA
| | - L Oudejans
- Center for Environmental Solutions and Emergency Response, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC, USA
| | - W Calfee
- Center for Environmental Solutions and Emergency Response, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, NC, USA
| | - A Abdel-Hady
- Jacobs Technology Inc., Research Triangle Park, NC, USA
| | - M Monge
- Consolidated Safety Services, Inc., Research Triangle Park, NC, USA
| | - D Aslett
- Jacobs Technology Inc., Research Triangle Park, NC, USA
| |
Collapse
|
23
|
Robinson RT, Mahfooz N, Rosas-Mejia O, Liu Y, Hull NM. UV 222 disinfection of SARS-CoV-2 in solution. Sci Rep 2022; 12:14545. [PMID: 36008435 PMCID: PMC9406255 DOI: 10.1038/s41598-022-18385-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Accepted: 08/10/2022] [Indexed: 11/29/2022] Open
Abstract
There is an urgent need for evidence-based engineering controls to reduce transmission of SARS-CoV-2, which causes COVID-19. Although ultraviolet (UV) light is known to inactivate coronaviruses, conventional UV lamps contain toxic mercury and emit wavelengths (254 nm) that are more hazardous to humans than krypton chlorine excimer lamps emitting 222 nm (UV222). Here we used culture and molecular assays to provide the first dose response for SARS-CoV-2 solution exposed to UV222. Culture assays (plaque infectivity to Vero host) demonstrated more than 99.99% disinfection of SARS-CoV-2 after a UV222 dose of 8 mJ/cm2 (pseudo-first order rate constant = 0.64 cm2/mJ). Immediately after UV222 treatment, RT-qPCR assays targeting the nucleocapsid (N) gene demonstrated ~ 10% contribution of N gene damage to disinfection kinetics, and an ELISA assay targeting the N protein demonstrated no contribution of N protein damage to disinfection kinetics. Molecular results suggest other gene and protein damage contributed more to disinfection. After 3 days incubation with host cells, RT-qPCR and ELISA kinetics of UV222 treated SARS-CoV-2 were similar to culture kinetics, suggesting validity of using molecular assays to measure UV disinfection without culture. These data provide quantitative disinfection kinetics which can inform implementation of UV222 for preventing transmission of COVID-19.
Collapse
Affiliation(s)
- Richard T Robinson
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, USA
- Infectious Diseases Institute, The Ohio State University, Columbus, OH, USA
| | - Najmus Mahfooz
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, USA
| | - Oscar Rosas-Mejia
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, USA
| | - Yijing Liu
- Department of Civil, Environmental, and Geodetic Engineering, The Ohio State University, 2070 Neil Ave, Hitchcock 417C, Columbus, OH, 43210, USA
| | - Natalie M Hull
- Department of Civil, Environmental, and Geodetic Engineering, The Ohio State University, 2070 Neil Ave, Hitchcock 417C, Columbus, OH, 43210, USA.
- Sustainability Institute, The Ohio State University, Columbus, OH, USA.
| |
Collapse
|
24
|
Ma B, Seyedi S, Wells E, McCarthy D, Crosbie N, Linden KG. Inactivation of biofilm-bound bacterial cells using irradiation across UVC wavelengths. WATER RESEARCH 2022; 217:118379. [PMID: 35429876 DOI: 10.1016/j.watres.2022.118379] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2021] [Revised: 02/17/2022] [Accepted: 03/28/2022] [Indexed: 06/14/2023]
Abstract
Opportunistic pathogens (OPs), such as Pseudomonas spp., Legionella spp., and mycobacteria, have been detected in biofilms in drinking water distribution systems and water storage tanks and pose potential risks to finished drinking water quality and safety. Emerging UV technologies, such as UV light emitting diodes (LEDs) and krypton chloride (KrCl*) excimers, could provide an alternative to chemical-based secondary disinfection (i.e., chlorine or chloramines) for controlling biofilm-bound OPs. UV systems offer long lifetimes, ability to select wavelength, small size with high power density, and limited-to-no disinfection by-product formation. In this study, inactivation of biofilm-bound Pseudomonas aeruginosa cells across different maturities was investigated using five UVC devices with different peak emission wavelengths, including a KrCl* excimer (222 nm), a low pressure mercury vapor lamp (254 nm), and three UV LEDs (260 nm, 270 nm, and 282 nm). The UV transmittance and absorbance through the biofilm structure was also documented for the first time using a unique approach. Our results show all UVC devices can inactivate biofilm-bound P. aeruginosa cells up to a point, among which the UV LED with peak emission at 270 nm provided the best disinfection performance. UV sensitivities of biofilm-bound cells decreased with biofilm maturity and while initial rates of inactivation were high, no more than 1.5-2.5 log reduction was possible. Re-suspended biofilm bacteria in aqueous solution were highly sensitive to UV, reaching greater than 6 log reduction. UV shielding by biofilm constituents was observed and was likely one of the reasons for UV resistance but did not fully explain the difference in UV sensitivity between biofilm-bound cells versus planktonic cells. This study improves upon fundamental knowledge and provides guidance for innovative designs using emerging UV technologies for biofilm and pathogen control in water distribution systems.
Collapse
Affiliation(s)
- Ben Ma
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Dr., Boulder, CO, 80303, United States
| | - Saba Seyedi
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Dr., Boulder, CO, 80303, United States
| | - Emma Wells
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Dr., Boulder, CO, 80303, United States
| | - David McCarthy
- Department of Civil Engineering, Monash University, Clayton, Vic, 3800, Australia
| | | | - Karl G Linden
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, 4001 Discovery Dr., Boulder, CO, 80303, United States.
| |
Collapse
|
25
|
Liang M, Yu C, Dai S, Cheng H, Li W, Lai F, Ma L, Liu X. Reactivity and kinetics of 1,3-butadiene under ultraviolet irradiation at 254 nm. BMC Chem 2022; 16:4. [PMID: 35180888 PMCID: PMC8857861 DOI: 10.1186/s13065-022-00800-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 02/14/2022] [Indexed: 12/03/2022] Open
Abstract
The reaction process of gaseous 1,3-butadiene following ultraviolet irradiation at the temperature range from 298 to 323 K under nitrogen atmosphere was monitored by UV–vis spectrophotometry. A gaseous mini-reactor was used as a reaction vessel and could be directly monitored in a UV–vis spectrophotometer. We investigated the reactivity and kinetics of 1,3-butadiene under non-UV and UV irradiation to evaluate its photochemical stability. A second-order kinetic model with 50.48 kJ·mol–1 activation energy fitted the reaction data for non-UV irradiation, whereas a first-order kinetic model was appropriate in the case of UV irradiation with activation energies of 19.92–43.65 kJ mol–1. This indicates that ultraviolet light could accelerate the photolysis reaction rate of 1,3-butadiene. In addition, the reaction products were determined using gas chromatography-mass spectrometry (GC–MS), and the reaction pathways were identified. The photolysis of 1,3-butadiene gave rise to various volatile products by cleavage and rearrangement of single C–C bonds. The differences between dimerization and dissociation of 1,3-butadiene under ultraviolet irradiation were elucidated by combining experimental and theoretical methods. The present findings provide fundamental insight into the photochemistry of 1,3-butadiene compounds.
Collapse
Affiliation(s)
- Min Liang
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Chang Yu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Suyi Dai
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Haijun Cheng
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Weiguang Li
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Fang Lai
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China
| | - Li Ma
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
| | - Xiongmin Liu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning, 530004, China.
| |
Collapse
|
26
|
Matafonova G, Batoev V. Dual-wavelength light radiation for synergistic water disinfection. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 806:151233. [PMID: 34715208 DOI: 10.1016/j.scitotenv.2021.151233] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 10/18/2021] [Accepted: 10/22/2021] [Indexed: 06/13/2023]
Abstract
Development of the narrow-band mercury-free light sources, such as light emitting diodes (LEDs) and excilamps, has stimulated research on inactivation of pathogenic microorganisms by dual-wavelength light radiation. To date, dual-wavelength light radiation has emerged as an advanced tool for enhancing microbial inactivation in water in view of potential synergistic effect. This is the first review that aims at elucidating its mechanisms under dual-wavelength light exposure and surveying a body of related literature in terms of yes-or-no synergy. We have proposed three key inactivation mechanisms, which function in the estimated spectrum ranges I (190-254 nm), II (250-320 nm) and III (300-405 nm) and provide a synergistic effect when combined. These mechanisms involve proteins damage and DNA repair suppression (I), direct and indirect DNA damage (II) and generation of reactive oxygen species (ROS) by endogenous photosensitizers (III), such as porphyrins and flavins. A synergy under dual-wavelength light irradiation simultaneously or sequentially occurs if coupling two wavelengths of different ranges (I + II, I + III, II + III) in order to trigger different inactivation mechanisms. Recent advances of dual-wavelength light strategy in photodynamic therapy could be applied for water disinfection. They bring opportunities for applying the sources of near-UV and visible radiation and making the disinfection processes more energy- and cost-effective. From this standpoint, the synergistically efficient dual-wavelength combinations II + III and the combinations within the extended to 700 nm range III (near-UV + VIS) appear to be promising for developing novel advanced oxidation processes for disinfection of real turbid waters.
Collapse
Affiliation(s)
- Galina Matafonova
- Laboratory of Engineering Ecology, Baikal Institute of Nature Management, Siberian Branch of Russian Academy of Sciences, Ulan-Ude, Russia.
| | - Valeriy Batoev
- Laboratory of Engineering Ecology, Baikal Institute of Nature Management, Siberian Branch of Russian Academy of Sciences, Ulan-Ude, Russia
| |
Collapse
|
27
|
Minh Tran HD, Boivin S, Kodamatani H, Ikehata K, Fujioka T. Potential of UV-B and UV-C irradiation in disinfecting microorganisms and removing N-nitrosodimethylamine and 1,4-dioxane for potable water reuse: A review. CHEMOSPHERE 2022; 286:131682. [PMID: 34358895 DOI: 10.1016/j.chemosphere.2021.131682] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2021] [Revised: 06/25/2021] [Accepted: 07/24/2021] [Indexed: 06/13/2023]
Abstract
The ultraviolet (UV)-based advanced oxidation process (AOP) is a powerful technology for removing pathogenic microorganisms and contaminants of emerging concern (CECs) from water. AOP in potable water reuse has been predominantly based on traditional low-pressure mercury (LP-Hg) lamps at 254 nm wavelength, supplemented by hydrogen peroxide addition. In this review, we assessed the potential of unconventional UV wavelengths (UV-B, 280-315 nm and UV-C, 100-280 nm) compared to conventional one (254 nm) in achieving the attenuation of pathogens and CECs. At the same UV doses, conventional 254 nm LP-Hg lamps and other sources such as, 222 nm KrCl lamps and 265 nm UV-LEDs, showed similar disinfection capability for viruses, protozoa, and bacteria, and the effect of hydrogen peroxide (H2O2) addition on disinfection remained unclear. The attenuation levels of key CECs in potable water reuse (N-nitrosodimethylamine and 1,4-dioxane) by 185 + 254 nm LP-Hg or 222 nm KrCl lamps were generally greater than those by conventional 254 nm LP-Hg and other UV lamps. CEC degradation was generally enhanced by H2O2 addition. Overall, our review suggests that 222 nm KrCl or 185 + 254 nm LP-Hg lamps with the addition of H2O2 would be the best alternative to conventional 254 nm LP-Hg lamps for achieving target removal levels of both pathogens and CECs in potable water reuse.
Collapse
Affiliation(s)
- Hai Duc Minh Tran
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Sandrine Boivin
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan
| | - Hitoshi Kodamatani
- Graduate School of Science and Engineering, Kagoshima University, 1-21-24 Korimoto, Kagoshima, 890-0065, Japan
| | - Keisuke Ikehata
- Ingram School of Engineering, Texas State University, 601 University Drive, San Marcos, TX, 78666, USA
| | - Takahiro Fujioka
- Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan.
| |
Collapse
|
28
|
Ma B, Gundy PM, Gerba CP, Sobsey MD, Linden KG. UV Inactivation of SARS-CoV-2 across the UVC Spectrum: KrCl* Excimer, Mercury-Vapor, and Light-Emitting-Diode (LED) Sources. Appl Environ Microbiol 2021; 87:e0153221. [PMID: 34495736 PMCID: PMC8552892 DOI: 10.1128/aem.01532-21] [Citation(s) in RCA: 57] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 08/31/2021] [Indexed: 01/22/2023] Open
Abstract
Effective disinfection technology to combat severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can help reduce viral transmission during the ongoing COVID-19 global pandemic and in the future. UV devices emitting UVC irradiation (200 to 280 nm) have proven to be effective for virus disinfection, but limited information is available for SARS-CoV-2 due to the safety requirements of testing, which is limited to biosafety level 3 (BSL3) laboratories. In this study, inactivation of SARS-CoV-2 in thin-film buffered aqueous solution (pH 7.4) was determined across UVC irradiation wavelengths of 222 to 282 nm from krypton chloride (KrCl*) excimers, a low-pressure mercury-vapor lamp, and two UVC light-emitting diodes. Our results show that all tested UVC devices can effectively inactivate SARS-CoV-2, among which the KrCl* excimer had the best disinfection performance (i.e., highest inactivation rate). The inactivation rate constants of SARS-CoV-2 across wavelengths are similar to those for murine hepatitis virus (MHV) from our previous investigation, suggesting that MHV can serve as a reliable surrogate of SARS-CoV-2 with a lower BSL requirement (BSL2) during UV disinfection tests. This study provides fundamental information on UVC's action on SARS-CoV-2 and guidance for achieving reliable disinfection performance with UVC devices. IMPORTANCE UV light is an effective tool to help stem the spread of respiratory viruses and protect public health in commercial, public, transportation, and health care settings. For effective use of UV, there is a need to determine the efficiency of different UV wavelengths in killing pathogens, specifically SARS-CoV-2, to support efforts to control the ongoing COVID-19 global pandemic and future coronavirus-caused respiratory virus pandemics. We found that SARS-CoV-2 can be inactivated effectively using a broad range of UVC wavelengths, and 222 nm provided the best disinfection performance. Interestingly, 222-nm irradiation has been found to be safe for human exposure up to thresholds that are beyond those effective for inactivating viruses. Therefore, applying UV light from KrCl* excimers in public spaces can effectively help reduce viral aerosol or surface-based transmissions.
Collapse
Affiliation(s)
- Ben Ma
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Patricia M. Gundy
- Department of Environmental Science, University of Arizona, Tucson, Arizona, USA
| | - Charles P. Gerba
- Department of Environmental Science, University of Arizona, Tucson, Arizona, USA
| | - Mark D. Sobsey
- Department of Environmental Science and Engineering, Gillings School of Public Health, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Karl G. Linden
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| |
Collapse
|
29
|
Ma B, Linden YS, Gundy PM, Gerba CP, Sobsey MD, Linden KG. Inactivation of Coronaviruses and Phage Phi6 from Irradiation across UVC Wavelengths. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2021; 8:425-430. [PMID: 37566360 PMCID: PMC7986976 DOI: 10.1021/acs.estlett.1c00178] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 03/10/2021] [Accepted: 03/11/2021] [Indexed: 05/19/2023]
Abstract
Ultraviolet (UV) devices emitting UVC irradiation (200-280 nm) have proven to be effective for virus disinfection, especially on surfaces and in air, due to their rapid effectiveness and limited to no material corrosion. Numerous studies of UV-induced inactivation focused on nonenveloped viruses. Little is known about UVC action on enveloped viruses across UVC wavelengths. In this study, we determined inactivation efficiencies of two coronaviruses (ssRNA) and an enveloped dsRNA bacteriophage surrogate in buffered aqueous solution (pH 7.4) using five commonly available UVC devices that uniquely emit light at different wavelengths spanning 222 nm emitting krypton chloride (KrCl*) excimers to 282 nm emitting UVC LEDs. Our results show that enveloped viruses can be effectively inactivated using UVC devices, among which the KrCl* excimer had the best disinfection performance (i.e., highest inactivation rate) for all three enveloped viruses. The coronaviruses exhibited similar sensitivities to UV irradiation across the UVC range, whereas the bacteriophage surrogate was much more resistant and exhibited significantly higher sensitivity to the Far UVC (<230 nm) irradiation. This study provides necessary information and guidance for using UVC devices for enveloped virus disinfection, which may help control virus transmission in public spaces during the ongoing COVID-19 pandemic and beyond.
Collapse
Affiliation(s)
- Ben Ma
- Department of Civil, Environmental,
and Architectural Engineering, University of Colorado
Boulder, 4001 Discovery Dr., Boulder, Colorado
80303, United States
| | - Yarrow S. Linden
- Department of Civil, Environmental,
and Architectural Engineering, University of Colorado
Boulder, 4001 Discovery Dr., Boulder, Colorado
80303, United States
| | - Patricia M. Gundy
- Department of Environmental Science,
University of Arizona, 2959 W. Calle
Agua Nueva, Tucson, Arizona 85745, United
States
| | - Charles P. Gerba
- Department of Environmental Science,
University of Arizona, 2959 W. Calle
Agua Nueva, Tucson, Arizona 85745, United
States
| | - Mark D. Sobsey
- Department of Environmental Science and
Engineering, Gillings School of Public Health, University
of North Carolina, Chapel Hill, North Carolina
27599, United States
| | - Karl G. Linden
- Department of Civil, Environmental,
and Architectural Engineering, University of Colorado
Boulder, 4001 Discovery Dr., Boulder, Colorado
80303, United States
| |
Collapse
|
30
|
Hessling M, Haag R, Sieber N, Vatter P. The impact of far-UVC radiation (200-230 nm) on pathogens, cells, skin, and eyes - a collection and analysis of a hundred years of data. GMS HYGIENE AND INFECTION CONTROL 2021; 16:Doc07. [PMID: 33643774 PMCID: PMC7894148 DOI: 10.3205/dgkh000378] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Background: The ongoing coronavirus pandemic requires new disinfection approaches, especially for airborne viruses. The 254 nm emission of low-pressure vacuum lamps is known for its antimicrobial effect, but unfortunately, this radiation is also harmful to human cells. Some researchers published reports that short-wavelength ultraviolet light in the spectral region of 200-230 nm (far-UVC) should inactivate pathogens without harming human cells, which might be very helpful in many applications. Methods: A literature search on the impact of far-UVC radiation on pathogens, cells, skin and eyes was performed and median log-reduction doses for different pathogens and wavelengths were calculated. Observed damage to cells, skin and eyes was collected and presented in standardized form. Results: More than 100 papers on far-UVC disinfection, published within the last 100 years, were found. Far-UVC radiation, especially the 222 nm emission of KrCl excimer lamps, exhibits strong antimicrobial properties. The average necessary log-reduction doses are 1.3 times higher than with 254 nm irradiation. A dose of 100 mJ/cm2 reduces all pathogens by several orders of magnitude without harming human cells, if optical filters block emissions above 230 nm. Conclusion: The approach is very promising, especially for temporary applications, but the data is still sparse. Investigations with high far-UVC doses over a longer period of time have not yet been carried out, and there is no positive study on the impact of this radiation on human eyes. Additionally, far-UVC sources are unavailable in larger quantities. Therefore, this is not a short-term solution for the current pandemic, but may be suitable for future technological approaches for decontamination in rooms in the presence of people or for antisepsis.
Collapse
Affiliation(s)
- Martin Hessling
- Institute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Ulm, Germany
| | - Robin Haag
- Institute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Ulm, Germany
| | - Nicole Sieber
- Institute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Ulm, Germany
| | - Petra Vatter
- Institute of Medical Engineering and Mechatronics, Ulm University of Applied Sciences, Ulm, Germany
| |
Collapse
|
31
|
Kim DK, Kang DH. Investigation of a new UVC LEDs array continuous type water disinfection system for inactivating Escherichia coli O157:H7 according to flow rate and electrical energy efficiency analysis. Food Control 2021. [DOI: 10.1016/j.foodcont.2020.107470] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
32
|
Welch D, Brenner DJ. Improved Ultraviolet Radiation Film Dosimetry Using OrthoChromic OC-1 Film †. Photochem Photobiol 2020; 97:498-504. [PMID: 33294996 PMCID: PMC8547612 DOI: 10.1111/php.13364] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 11/30/2020] [Accepted: 12/02/2020] [Indexed: 02/04/2023]
Abstract
There is growing interest in far-UVC lighting, defined as wavelengths from 200 to 230 nm, because research has demonstrated these wavelengths to be an effective antimicrobial technology while posing a minimal hazard to human health. Far-UVC lighting is now being installed to directly irradiate spaces where humans are present, and it will be important to perform measurements to verify far-UVC lighting installations are operating within widely accepted exposure guidelines. In this work, we explore the use of a commercially available film, known as OrthoChromic OC-1, to measure ultraviolet radiation exposure. The film was tested with a variety of ultraviolet wavelengths and irradiance conditions, and the color change of the film was analyzed for increasing levels of radiant exposure. The film response extended over a dynamic range that was greater than the recommended exposure limits for far-UVC radiation so it can potentially be useful for health hazard monitoring. The spectrum of the incident ultraviolet radiation strongly affected the response of the film; therefore, for accurate measurements we recommend the measured spectrum match the spectrum used for calibration. Overall, dosimetry with this film provides a simple, accurate, and inexpensive method of quantifying ultraviolet radiation exposure that is suitable for far-UVC measurements.
Collapse
Affiliation(s)
- David Welch
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, USA
| |
Collapse
|
33
|
Raeiszadeh M, Adeli B. A Critical Review on Ultraviolet Disinfection Systems against COVID-19 Outbreak: Applicability, Validation, and Safety Considerations. ACS PHOTONICS 2020; 7:2941-2951. [PMID: 37556269 PMCID: PMC7571309 DOI: 10.1021/acsphotonics.0c01245] [Citation(s) in RCA: 156] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Indexed: 05/19/2023]
Abstract
The global health-threatening crisis from the COVID-19 pandemic, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), highlights the scientific and engineering potentials of applying ultraviolet (UV) disinfection technologies for biocontaminated air and surfaces as the major media for disease transmission. Nowadays, various environmental public settings worldwide, from hospitals and health care facilities to shopping malls and airports, are considering implementation of UV disinfection devices for disinfection of frequently touched surfaces and circulating air streams. Moreover, the general public utilizes UV sterilization devices for various surfaces, from doorknobs and keypads to personal protective equipment, or air purification devices with an integrated UV disinfection technology. However, limited understanding of critical UV disinfection aspects can lead to improper use of this promising technology. In this work, fundamentals of UV disinfection phenomena are addressed; furthermore, the essential parameters and protocols to guarantee the efficacy of the UV sterilization process in a human-safe manner are systematically elaborated. In addition, the latest updates from the open literature on UV dose requirements for incremental log removal of SARS-CoV-2 are reviewed remarking the advancements and existing knowledge gaps. This study, along with the provided illustrations, will play an essential role in the design and fabrication of effective, reliable, and safe UV disinfection systems applicable to preventing viral contagion in the current COVID-19 pandemic, as well as potential future epidemics.
Collapse
Affiliation(s)
- Milad Raeiszadeh
- Department of Chemical and Biological
Engineering, The University of British
Columbia, Vancouver, BC V6T 1Z4,
Canada
- Department of Research and
Development, Acuva Technologies, Burnaby,
BC V5J 5G5, Canada
| | - Babak Adeli
- Department of Research and
Development, Acuva Technologies, Burnaby,
BC V5J 5G5, Canada
| |
Collapse
|
34
|
Oh C, Sun PP, Araud E, Nguyen TH. Mechanism and efficacy of virus inactivation by a microplasma UV lamp generating monochromatic UV irradiation at 222 nm. WATER RESEARCH 2020; 186:116386. [PMID: 32927421 DOI: 10.1016/j.watres.2020.116386] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 09/01/2020] [Accepted: 09/02/2020] [Indexed: 05/24/2023]
Abstract
This study evaluated the potential of a microplasma UV lamp as an alternative UV source to the current mercury-based (Hg-based) UV lamp for water disinfection. We developed a set of PCR-based molecular assays (long-range qPCR, DNase, and binding assay) to quantify the adenovirus genome, capsid, and fiber damage with a wide detection range (100.5-106.5 PFU/mL). We used these molecular assays to characterize adenovirus (AdV) inactivation kinetics by microplasma UV that produced monochromatic UV at 222 nm. We found that the inactivation rate constant (0.142 cm2/mJ) due to microplasma UV was 4.4 times higher than that of low-pressure Hg UV (0.032 cm2/mJ). This high efficacy was attributed to monochromatic UV wavelength at 222 nm damaging the AdV capsid protein. The results of these molecular assays also proved that microplasma UV and medium-pressure Hg UV with a bandpass filter at 223 nm (MPUV223nm) have a similar influence on AdV (p>0.05). We then estimated the relative energy efficiency of MPUV and microplasma UV to LPUV for 4 log reduction of the viruses. We found that the microplasma UV resulted in higher inactivation rate constants for viruses than the current Hg-based UV. Consequently, microplasma UV could be more energy efficient than low-pressure Hg UV for water disinfection if the wall-plug efficiency of the microplasma UV lamp improved to 8.4% (currently 1.5%). Therefore, the microplasma UV lamp is a promising option for water disinfection.
Collapse
Affiliation(s)
- Chamteut Oh
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States
| | - Peter P Sun
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, United States
| | - Elbashir Araud
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States; Holonyak Micro & Nanotechnology Lab, University of Illinois at Urbana-Champaign, United States
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States; Institute of Genomic Biology, University of Illinois at Urbana-Champaign, United States.
| |
Collapse
|
35
|
Gerchman Y, Mamane H, Friedman N, Mandelboim M. UV-LED disinfection of Coronavirus: Wavelength effect. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY. B, BIOLOGY 2020; 212:112044. [PMID: 33022467 PMCID: PMC7521879 DOI: 10.1016/j.jphotobiol.2020.112044] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/03/2020] [Accepted: 09/10/2020] [Indexed: 11/12/2022]
Abstract
UV light-emitting diodes (UV LEDs) are an emerging technology and a UV source for pathogen inactivation, however low UV-LED wavelengths are costly and have low fluence rate. Our results suggest that the sensitivity of human Coronavirus (HCoV-OC43 used as SARS-CoV-2 surrogate) was wavelength dependent with 267 nm ~ 279 nm > 286 nm > 297 nm. Other viruses showed similar results, suggesting UV LED with peak emission at ~286 nm could serve as an effective tool in the fight against human Coronaviruses.
Collapse
Affiliation(s)
- Yoram Gerchman
- Department of Biology and Environment, Faculty of Natural Science, University of Haifa and Oranim College, Tivon 3600600, Israel.
| | - Hadas Mamane
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv 69978, Israel
| | - Nehemya Friedman
- Central Virology Laboratory, Ministry of Health, Chaim Sheba Medical Center, Tel-Hashomer, Ramat-Gan, Israel; Department of Epidemiology and Preventive Medicine, School of Public Health, Tel-Aviv University, Israel
| | - Michal Mandelboim
- Central Virology Laboratory, Ministry of Health, Chaim Sheba Medical Center, Tel-Hashomer, Ramat-Gan, Israel; Department of Epidemiology and Preventive Medicine, School of Public Health, Tel-Aviv University, Israel
| |
Collapse
|
36
|
Hadi J, Dunowska M, Wu S, Brightwell G. Control Measures for SARS-CoV-2: A Review on Light-Based Inactivation of Single-Stranded RNA Viruses. Pathogens 2020; 9:E737. [PMID: 32911671 PMCID: PMC7558314 DOI: 10.3390/pathogens9090737] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 09/04/2020] [Accepted: 09/05/2020] [Indexed: 12/20/2022] Open
Abstract
SARS-CoV-2 is a single-stranded RNA virus classified in the family Coronaviridae. In this review, we summarize the literature on light-based (UV, blue, and red lights) sanitization methods for the inactivation of ssRNA viruses in different matrixes (air, liquid, and solid). The rate of inactivation of ssRNA viruses in liquid was higher than in air, whereas inactivation on solid surfaces varied with the type of surface. The efficacy of light-based inactivation was reduced by the presence of absorptive materials. Several technologies can be used to deliver light, including mercury lamp (conventional UV), excimer lamp (UV), pulsed-light, and light-emitting diode (LED). Pulsed-light technologies could inactivate viruses more quickly than conventional UV-C lamps. Large-scale use of germicidal LED is dependent on future improvements in their energy efficiency. Blue light possesses virucidal potential in the presence of exogenous photosensitizers, although femtosecond laser (ultrashort pulses) can be used to circumvent the need for photosensitizers. Red light can be combined with methylene blue for application in medical settings, especially for sanitization of blood products. Future modelling studies are required to establish clearer parameters for assessing susceptibility of viruses to light-based inactivation. There is considerable scope for improvement in the current germicidal light-based technologies and practices.
Collapse
Affiliation(s)
- Joshua Hadi
- AgResearch Ltd., Hopkirk Research Institute, Cnr University Ave and Library Road, Massey University, Palmerston North 4442, New Zealand; (J.H.); (S.W.)
| | - Magdalena Dunowska
- School of Veterinary Science, Massey University Manawatu (Turitea) Tennent Drive, Palmerston North 4474, New Zealand;
| | - Shuyan Wu
- AgResearch Ltd., Hopkirk Research Institute, Cnr University Ave and Library Road, Massey University, Palmerston North 4442, New Zealand; (J.H.); (S.W.)
| | - Gale Brightwell
- AgResearch Ltd., Hopkirk Research Institute, Cnr University Ave and Library Road, Massey University, Palmerston North 4442, New Zealand; (J.H.); (S.W.)
- New Zealand Food Safety Science and Research Centre, Massey University Manawatu (Turitea) Tennent Drive, Palmerston North 4474, New Zealand
| |
Collapse
|
37
|
Moreno-Andrés J, Rueda-Márquez JJ, Homola T, Vielma J, Moríñigo MÁ, Mikola A, Sillanpää M, Acevedo-Merino A, Nebot E, Levchuk I. A comparison of photolytic, photochemical and photocatalytic processes for disinfection of recirculation aquaculture systems (RAS) streams. WATER RESEARCH 2020; 181:115928. [PMID: 32504908 DOI: 10.1016/j.watres.2020.115928] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 05/08/2020] [Accepted: 05/10/2020] [Indexed: 06/11/2023]
Abstract
The development of technologically advanced recirculation aquaculture systems (RAS) implies the reuse of water in a high recirculation rate (>90%). One of the most important phases for water management in RAS involves water disinfection in order to avoid proliferation of potential pathogens and related fish diseases. Accordingly, different approaches have been assessed in this study by performing a comparison of photolytic (UV-LEDs) at different wavelengths (λ = 262, 268 and 262 + 268 nm), photochemical (UV-LEDs/H2O2, UV-LEDs/HSO5- and UV-LEDs/S2O82-) and photocatalytic (TiO2/SiO2/UV-LEDs and ZnO/SiO2/UV-LEDs) processes for the disinfection of water in RAS streams. Different laboratory tests were performed in batch scale with real RAS stream water and naturally occurring bacteria (Aeromonas hydrophyla and Citrobacter gillenii) as target microorganisms. Regarding photolytic processes, higher inactivation rates were obtained by combining λ262+268 in front of single wavelengths. Photochemical processes showed higher efficiencies by comparison with a single UV-C process, especially at 10 mg L-1 of initial oxidant dose. The inactivation kinetic rate constant was improved in the range of 15-38%, with major efficiency for UV/H2O2 ∼ UV/HSO5- > UV/S2O82-. According to photocatalytic tests, higher efficiencies were obtained by improving the inactivation kinetic rate constant up to 55% in comparison with a single UV-C process. Preliminary cost estimation was conducted for all tested disinfection methods. Those results suggest the potential application of UV-LEDs as promoter of different photochemical and photocatalytic processes, which are able to enhance disinfection in particular cases, such as the aquaculture industry.
Collapse
Affiliation(s)
- Javier Moreno-Andrés
- Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, INMAR-Marine Research Institute, CEIMAR- International Campus of Excellence of the Sea, University of Cadiz, Spain; Grupo de Procesos de Oxidación Avanzada, Departamento de Ingeniería Textil y Papelera, Universitat Politècnica de València, Campus de Alcoy, Alcoy, Spain.
| | - Juan José Rueda-Márquez
- Department of Separation Science, School of Engineering Science, Lappeenranta-Lahti University of Technology LUT, Sammonkatu 12, 50130 Mikkeli, Finland
| | - Tomáš Homola
- R&D Center for Low-Cost Plasma and Nanotechnology Surface Modifications (CEPLANT), Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 267/2, 611 37, Brno, Czech Republic
| | - Jouni Vielma
- Natural Resources Institute Finland, Survontie 9A, 40500, Jyväskylä, Finland
| | | | - Anna Mikola
- Water and Wastewater Engineering Research Group, School of Engineering, Aalto University, PO Box 15200, FI-00076, Aalto, Finland
| | - Mika Sillanpää
- School of Civil Engineering and Surveying, Faculty of Health, Engineering and Sciences, University of Southern Queensland, West Street, Toowoomba, 4350 QLD, Australia; Institute of Research and Development, Faculty of Environment and Chemical Engineering, Duy Tan University, Da Nang 550000, Vietnam
| | - Asunción Acevedo-Merino
- Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, INMAR-Marine Research Institute, CEIMAR- International Campus of Excellence of the Sea, University of Cadiz, Spain
| | - Enrique Nebot
- Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, INMAR-Marine Research Institute, CEIMAR- International Campus of Excellence of the Sea, University of Cadiz, Spain
| | - Irina Levchuk
- Water and Wastewater Engineering Research Group, School of Engineering, Aalto University, PO Box 15200, FI-00076, Aalto, Finland
| |
Collapse
|
38
|
Li Y, Niu M, Xu X, Bian H, Chen J, Wen J, Yu C, Liang M, Ma L, Lai F, Liu X. Characteristics and kinetics of the glycerol ester of rosin viaan oxidation process under ultraviolet irradiation. NEW J CHEM 2020. [DOI: 10.1039/c9nj04439f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A self-designed mini gas–solid reaction device was applied as promising equipment to investigate the oxidation characteristics and kinetics of the glycerol ester of rosin (GER) under 254 nm UV irradiation in air.
Collapse
Affiliation(s)
- Yuanlin Li
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Mengmeng Niu
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Xingliang Xu
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Hao Bian
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Jing Chen
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Jiahua Wen
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Chang Yu
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Min Liang
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Li Ma
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Fang Lai
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| | - Xiongmin Liu
- School of Chemistry and Chemical Engineering
- Guangxi University
- Nanning 530004
- China
| |
Collapse
|
39
|
Sholtes K, Linden KG. Pulsed and continuous light UV LED: microbial inactivation, electrical, and time efficiency. WATER RESEARCH 2019; 165:114965. [PMID: 31437635 DOI: 10.1016/j.watres.2019.114965] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 08/06/2019] [Accepted: 08/08/2019] [Indexed: 06/10/2023]
Abstract
Ultraviolet light emitting diodes (UV LEDs) have increasing applications in the inactivation of microorganisms in water, air, food, and on surfaces. System designers currently have metrics for comparison of the microbial and energy efficiency of UV LEDs, but these have not included a time component. Without including the time efficiency of a UV LED, neither the fluence-basis nor the electrical-basis of comparison clarifies which UV LED wavelength and operating condition is optimal for a design space. This research explores microbial inactivation of UV LEDs at various wavelengths under continuous and pulsing operating conditions. Planktonic microorganisms of relevance to public water supplies and UV system design are included: E. coli and MS-2 for benchmarking against previous studies and P. aeruginosa which has not been studied in pulsed systems or for continuous and combined UV LED wavelengths. Pulsing UV LEDs at various duty rates (percent of cycle spent on) and frequencies (number of cycles per second) does not result in a statistically significant disinfection performance difference over the continuous light operation at that respective wavelength. UV LEDs emitting at peak wavelengths corresponding to the peak action spectrum of a microorganism are optimal on a fluence-basis, but these are typically less electrically efficient UV LEDs. System designers can compare the normalized microbial inactivation, electrical, and time efficiencies (ENETO) of various UV LEDs; ENETO ≥1 for a pulsing condition ensures equal or improved efficiency compared to the continuous light condition while expanding the lifetime of the UV LED and decreasing the size or cost of associated power supplies.
Collapse
Affiliation(s)
- Kari Sholtes
- Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, USA
| | - Karl G Linden
- Department of Civil, Environmental and Architectural Engineering, University of Colorado Boulder, USA.
| |
Collapse
|
40
|
Sholtes K, Keliher R, Linden KG. Standardization of a UV LED Peak Wavelength, Emission Spectrum, and Irradiance Measurement and Comparison Protocol. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:9755-9763. [PMID: 31335130 DOI: 10.1021/acs.est.9b02567] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Standard protocols for the measurement of irradiance, peak wavelength, and emission spectra have not yet been established for UV LED devices. This lack of standardization creates an uneven field for comparison between products. A detailed protocol was developed and tested in 14 facilities spanning manufacturers of UV LEDs and devices and research institutions in seven different countries. This protocol includes equipment calibration specifications, methods for the measurement and comparison calculations of irradiance and emission spectra, methods for the determination of peak wavelength, quality control and quality assurance steps, and industry-wide tolerances to error for each type of measurement. Measurements of the same source by operators using different equipment resulted in 2-10× the error found when measurement equipment provided as part of the study was used by each participant. The data were used to identify outliers, determine prediction intervals, and define acceptable tolerances to error. With this protocol, manufacturers have a means to report their UV LED specifications with verifiable quality control and quality assurance steps. The protocol and data generated from this study will create more confidence in the industry and standardize the comparison of UV LEDs by consumers, researchers, designers, and regulators.
Collapse
Affiliation(s)
- Kari Sholtes
- Department of Civil, Environmental, and Architectural Engineering , University of Colorado Boulder , Boulder , Colorado 80309 , United States
| | - Ryan Keliher
- Department of Civil, Environmental, and Architectural Engineering , University of Colorado Boulder , Boulder , Colorado 80309 , United States
| | - Karl G Linden
- Department of Civil, Environmental, and Architectural Engineering , University of Colorado Boulder , Boulder , Colorado 80309 , United States
| |
Collapse
|
41
|
Linden KG, Hull N, Speight V. Thinking Outside the Treatment Plant: UV for Water Distribution System Disinfection. Acc Chem Res 2019; 52:1226-1233. [PMID: 31038919 DOI: 10.1021/acs.accounts.9b00060] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
This work critically evaluates the current paradigm of water distribution system management and juxtaposes that with the potential benefits of employing UV irradiation, which we hope will catalyze a judicial re-evaluation of the current practices in water distribution system management and spur critical research and a new way of thinking about secondary disinfection across the extent of distribution systems. Given the recent advances in UV technology and the efficacy of UV disinfection against all pathogen classes, we now see UV applications for disinfection in many aspects of consumers lives: in water coolers, dishwashers, coffee makers, and disinfection of personal items like gym bags, water bottles, and toothbrushes. Public and regulatory concern over water quality and pathogens, especially the recent interest in building plumbing, calls out for new approaches to disinfection and distribution system management. We envision a new model for secondary disinfection in water distribution systems utilizing emerging germicidal UV LED-based disinfection. UV irradiation in water treatment can achieve high levels of disinfection of all pathogens and minimize or eliminate the formation of regulated disinfection byproducts. So why is UV not considered as a secondary disinfectant for distribution systems? In this Account, we lay out the logic as to the benefits and practicality of adding distributed UV treatment to assist in protection of distribution systems and protect water quality for human exposure. The possible locations of UV irradiation in distribution systems are envisioned, potentially including UV booster stations along the distribution network, UV in storage tanks or their inlet/outlets, LEDs distributed along pipe walls, small point of use/entry treatment systems for buildings/homes/taps, or submersible swimming or rolling UV LED drones to reach problem pipes and provide a "shock" treatment or provide sterilization after main breaks or repairs. The benefits of UV applications in water also include high effectiveness against chlorine-resistant protozoa, no added disinfection byproducts, and compatibility of adding of UV to existing secondary disinfection strategies for enhanced protection. Potential challenges and research needs are described, such as use of UV-compatible pipe materials, implementation of sensors to monitor distributed LEDs, management of waste heat from the rear surface of the LED, and understanding the potential for regrowth of opportunistic microorganisms. Another notable challenge is the relatively stagnant regulatory environment in some countries to develop frameworks for evaluation and acceptance of UV technology in distribution systems that require a chemical secondary disinfectant. Rapid advances in UV LED research has propelled the growth of this field, but needs still remain, including understanding behavior of biofilms in pipes under UV irradiation, including any beneficial effects that may be lost, the potential for fouling of LED emission surfaces and monitoring points, and provision of a distributed power network to run the LEDs. Regulators may want specific monitoring approaches and advances in real-time monitoring of microbial viability, and engineers may need to develop new approaches to overall management.
Collapse
Affiliation(s)
- Karl G. Linden
- University of Colorado Boulder, Civil, Environmental and Architectural Engineering, Boulder, Colorado 80309, United States
| | - Natalie Hull
- The Ohio State University, Department of Civil, Environmental, and Geodedic Engineering, Columbus, Ohio 43210, United States
| | - Vanessa Speight
- University of Sheffield, Department of Civil and Structural Engineering, University of Sheffield, Sheffield, S1 3JD U.K
| |
Collapse
|
42
|
Instantaneous Water Purification by Deep Ultraviolet Light in Water Waveguide: Escherichia Coli Bacteria Disinfection. WATER 2019. [DOI: 10.3390/w11050968] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The necessity of small water purification equipment has been increasing in recent years as a result of frequent natural disasters. Ultraviolet (UV) radiation treatment is an effective method for the disinfection of bacterial contaminants in water. As an emerging technology, disinfection by deep-ultraviolet light-emitting diodes (DUV-LEDs) is promising. Few studies have used the point-source characteristics of LEDs and have instead replaced mercury vapor lamps with LEDs. Here, we demonstrate the instantaneous purification of contaminated water by combining the point source characteristics of DUV-LEDs with a water waveguide (WW). The principle is based on the WW region acting as an effective DUV disinfector, whereby a high UV dose in a confined WW region can be applied to bacterial contaminants in a short period of time (around one second). We demonstrate the effect of this DUV-LED WW disinfection technique by showing the results of 3-log disinfection levels of water contaminated with Escherichia coli bacteria after a short treatment time. We believe that the combination of the point-source nature of DUV-LED emission, the water-waveguide effect, and a small photovoltaic cell paves the way toward environmentally friendly and emergency preparedness portable water purification equipment that instantaneously supplies clean water just before drinking.
Collapse
|
43
|
Umar M, Roddick F, Fan L. Moving from the traditional paradigm of pathogen inactivation to controlling antibiotic resistance in water - Role of ultraviolet irradiation. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 662:923-939. [PMID: 30795480 DOI: 10.1016/j.scitotenv.2019.01.289] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 01/21/2019] [Accepted: 01/22/2019] [Indexed: 06/09/2023]
Abstract
Ultraviolet (UV) irradiation has proven an effective tool for inactivating microorganisms in water. There is, however, a need to look at disinfection from a different perspective because microbial inactivation alone may not be sufficient to ensure the microbiological safety of the treated water since pathogenic genes may still be present, even after disinfection. Antibiotic resistance genes (ARGs) are of a particular concern since they enable microorganisms to become resistant to antibiotics. UV irradiation has been widely used for disinfection and more recently for destroying ARGs. While UV lamps remain the principal technology to achieve this objective, UV light emitting diodes (UV-LEDs) are novel sources of UV irradiation and have increasingly been reported in lab-scale investigations as a potential alternative. This review discusses the current state of the applications of UV technology for controlling antibiotic resistance during water and wastewater treatment. Since UV-LEDs possess several attractive advantages over conventional UV lamps, the impact of UV-LED characteristics (single vs combined wavelengths, and operational parameters such as periodic or pulsed and continuous irradiation, pulse repetition frequencies, duty cycle), type of organism, and fluence response, are critically reviewed with a view to highlighting the research needs for addressing future disinfection challenges. The energy efficiency of the reported UV processes is also evaluated with a focus on relating the findings to disinfection efficacy. The greater experience with UV lamps could be useful for investigating UV-LEDs for similar applications (i.e., antibiotic resistance control), and hence identification of future research directions.
Collapse
Affiliation(s)
- Muhammad Umar
- Norwegian Institute for Water Research (NIVA), Gaustadallèen 21, NO-0349 Oslo, Norway.
| | - Felicity Roddick
- Department of Chemical and Environmental Engineering, School of Engineering, RMIT University, Melbourne 3001, Australia
| | - Linhua Fan
- Department of Chemical and Environmental Engineering, School of Engineering, RMIT University, Melbourne 3001, Australia
| |
Collapse
|
44
|
Li Y, Liu X, Zhang Q, Wang B, Yu C, Rashid HU, Xu Y, Ma L, Lai F. Characteristics and Kinetics of Rosin Pentaerythritol Ester via Oxidation Process under Ultraviolet Irradiation. Molecules 2018; 23:molecules23112816. [PMID: 30380722 PMCID: PMC6278330 DOI: 10.3390/molecules23112816] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 10/24/2018] [Accepted: 10/26/2018] [Indexed: 11/16/2022] Open
Abstract
A self-designed reaction device was used as a promising equipment to investigate the oxidation characteristics and kinetics of rosin pentaerythritol ester (RPE) under UV irradiation. Photo-oxidation kinetics and the initial quantum yield (Φ) of RPE were calculated. The initial oxidation product of the photo-oxidation reaction-peroxide was analyzed by iodimetry. The peroxide concentration is related to the light intensity (I) and the temperature (T), and the increasing T and I would destabilize the RPE by accelerating peroxide forming. Photo-oxidation of RPE follows the pseudo first-order reaction kinetics. The relationship between activation energy and logarithm of light intensity (ln I) is linear, and it is expressed as Ea = -4.937ln I + 45.565. Φ was calculated by the photo-oxidation kinetics, and the average value of Φ was 7.19% in the light intensity range of 200⁻800 μW cm-2. This research can provide fundamental information for application of RPE, and help obtain a better understanding of the stability of rosin esters.
Collapse
Affiliation(s)
- Yuanlin Li
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Xiongmin Liu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Qiang Zhang
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Bo Wang
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Chang Yu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Haroon Ur Rashid
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Yiming Xu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Li Ma
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| | - Fang Lai
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
| |
Collapse
|