1
|
Zhang C, Sienkiewicz N, Struewing I, Mistry JH, Buse H, Hu Z, Lu J. Reconsider the burn: The transient effect of a chlorine burn on controlling opportunistic pathogens in a full-scale chloraminated engineered water system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 933:172690. [PMID: 38670361 DOI: 10.1016/j.scitotenv.2024.172690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 04/20/2024] [Accepted: 04/20/2024] [Indexed: 04/28/2024]
Abstract
Nitrification is a serious water-quality issue in chloraminated engineered water systems (EWSs). Nitrification is often remediated by a chlorine burn (i.e., a free‑chlorine conversion), a short-term switch from chloramination to chlorination in EWSs. Opportunistic pathogens (OPs) are the dominant infectious agents in EWSs. However, the responses of OPs to a chlorine burn are unknown. This study for the first time assessed how a chlorine burn affected OPs in a full-scale EWS. We determined the impact of a 1.5-month chlorine burn on four dominant OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in a representative full-scale chloraminated EWS in the United States. Legionella and Mycobacterium were the most abundant OPs. In the water main, the summed concentration of the four OPs during the chlorine burn [3.27 ± 1.58 log10(GCN·L-1); GCN: genome or gene copy number] was lower (p ≤ 0.001) than before the burn [4.83 ± 0.50 log10(GCN·L-1)]. After the burn, the summed concentration increased to 4.27 ± 0.68 log10(GCN·L-1), comparable to before the burn (p > 0.05), indicating a transient effect of the chlorine burn in the water main. At the residential sites, the summed concentrations of the four OPs were comparable (p > 0.05) at 5.50 ± 0.84, 5.27 ± 1.44, and 5.08 ± 0.71 log10(GCN·L-1) before, during, and after the chlorine burn, respectively. Therefore, the chlorine burn was less effective in suppressing OP (re)growth in the premise plumbing. The low effectiveness might be due to more significant water stagnation and disinfectant residual decay in the premise plumbing. Indeed, for the entire sampling period, the total chlorine residual concentration in the premise plumbing (1.8 mg Cl2·L-1) was lower than in the water main (2.4 mg Cl2·L-1). Consequently, for the entire sampling period, the summed concentration of the four OPs in the premise plumbing [5.26 ± 1.08 log10(GCN·L-1)] was significantly higher (p < 0.001) than in the water main [4.04 ± 1.25 log10(GCN·L-1)]. In addition, the chlorine burn substantially increased the levels of disinfection by-products (DBPs) in the water main. Altogether, a chlorine burn is transient or even ineffective in suppressing OP (re)growth but raises DBP concentrations in chloraminated EWSs. Therefore, the practice of chlorine burns to control nitrification should be optimized, reconsidered, or even replaced.
Collapse
Affiliation(s)
- Chiqian Zhang
- Civil Engineering Program, College of Engineering & Computer Science, Arkansas State University, AR 72467, United States
| | - Nathan Sienkiewicz
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, TX 75270, United States
| | - Helen Buse
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - Zhiqiang Hu
- Department of Civil & Environmental Engineering, University of Missouri, Columbia, MO 65211, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States.
| |
Collapse
|
2
|
Linz D, Struewing I, Sienkiewicz N, Steinman AD, Partridge CG, McIntosh K, Allen J, Lu J, Vesper S. Periodic Addition of Glucose Suppressed Cyanobacterial Abundance in Additive Lake Water Samples during the Entire Bloom Season. JOURNAL OF WATER RESOURCE AND PROTECTION 2024; 16:140-155. [PMID: 38487714 PMCID: PMC10936582 DOI: 10.4236/jwarp.2024.162009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/17/2024]
Abstract
Previously, we showed that prophylactic addition of glucose to Harsha Lake water samples could inhibit cyanobacteria growth, at least for a short period of time. The current study tested cyanobacterial control with glucose for the entire Harsha Lake bloom season. Water samples (1000 ml) were collected weekly from Harsha Lake during the algal-bloom season starting June 9 and lasting until August 24, 2022. To each of two 7-liter polypropylene containers, 500 ml of Harsha Lake water was added, and the containers were placed in a controlled environment chamber. To one container labeled "Treated," 0.15 g of glucose was added, and nothing was added to the container labeled "Control." After that, three 25 ml samples from each container were collected and used for 16S rRNA gene sequencing each week. Then 1000 ml of Harsha Lake water was newly collected each week, with 500 ml added to each container, along with the addition of 0.15 g glucose to the "Treated" container. Sequencing data were used to examine differences in the composition of bacterial communities between Treated and Control containers. Treatment with glucose altered the microbial communities by 1) reducing taxonomic diversity, 2) largely eliminating cyanobacterial taxa, and 3) increasing the relative abundance of subsets of non-cyanobacterial taxa (such as Proteobacteria and Actinobacteriota). These effects were observed across time despite weekly inputs derived directly from Lake water. The addition of glucose to a container receiving weekly additions of Lake water suppressed the cyanobacterial populations during the entire summer bloom season. The glucose appears to stimulate the diversity of certain bacterial taxa at the expense of the cyanobacteria.
Collapse
Affiliation(s)
- David Linz
- United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Ian Struewing
- United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | | | - Alan David Steinman
- Annis Water Resources Institute, Grand Valley State University, Muskegon, USA
| | | | - Kyle McIntosh
- Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee, USA
| | - Joel Allen
- United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jingrang Lu
- United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Stephen Vesper
- United States Environmental Protection Agency, Cincinnati, Ohio, USA
| |
Collapse
|
3
|
Zhao B, Liu R, Li Y, Xu H, Li X, Gu J, Zhang X, Wang Y, Wang Y. Changes of putative pathogenic species within the water bacterial community in large-scale drinking water treatment and distribution systems. WATER RESEARCH 2024; 249:120947. [PMID: 38043356 DOI: 10.1016/j.watres.2023.120947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 11/23/2023] [Accepted: 11/29/2023] [Indexed: 12/05/2023]
Abstract
Although the management of microbes in drinking water is of paramount importance for public health, there remain challenges in comprehensively examining pathogenic bacteria in the water supply system at the species level. In this study, high-throughput sequencing of nearly full-length 16S rRNA genes was performed to investigate the changes of the water bacterial community in three large-scale drinking water treatment plants (DWTPs) and their corresponding distribution systems during winter and summer. Our findings revealed significant differences in the bacterial community structure between winter and summer water samples for each DWTP and its distribution management area (DMA). In the groundwater-fed DWTP, selective enrichment of mycobacterial species was observed in both seasons, and the subsequent DMA also exhibited strong selection for specific mycobacterial species. In one of the surface water-fed DWTPs, certain Legionella species present in the source water in winter were selectively enriched in the bacterial community after pre-oxidation, although they were susceptible to the subsequent purification steps. A variety of putative pathogenic species (n = 83) were identified based on our pathogen identification pipeline, with the dominant species representing opportunistic pathogens commonly found in water supply systems. While pathogen removal primarily occurred during the purification processes of DWTPs, especially for surface water-fed plants, the relative abundance of pathogenic bacteria in the DMA water flora was lower than that in the DWTP effluent flora, indicating a diminished competitiveness of pathogens within the DMA ecosystem.
Collapse
Affiliation(s)
- Bei Zhao
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Ruyin Liu
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China; Weiqiao-UCAS Science and Technology Park, Binzhou Institute of Technology, Binzhou, Shandong, PR China.
| | - Yuxian Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Hao Xu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiangyi Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Junnong Gu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiaolan Zhang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Yue Wang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China
| | - Yansong Wang
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China
| |
Collapse
|
4
|
Jeon Y, Struewing I, McIntosh K, Tidd M, Webb L, Ryu H, Mash H, Lu J. Spatial and Temporal Variability of Saxitoxin-Producing Cyanobacteria in U.S. Urban Lakes. Toxins (Basel) 2024; 16:70. [PMID: 38393148 PMCID: PMC10892283 DOI: 10.3390/toxins16020070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 01/22/2024] [Accepted: 01/24/2024] [Indexed: 02/25/2024] Open
Abstract
Harmful cyanobacterial blooms (HCBs) are of growing global concern due to their production of toxic compounds, which threaten ecosystems and human health. Saxitoxins (STXs), commonly known as paralytic shellfish poison, are a neurotoxic alkaloid produced by some cyanobacteria. Although many field studies indicate a widespread distribution of STX, it is understudied relative to other cyanotoxins such as microcystins (MCs). In this study, we assessed eleven U.S. urban lakes using qPCR, sxtA gene-targeting sequencing, and 16S rRNA gene sequencing to understand the spatio-temporal variations in cyanobacteria and their potential role in STX production. During the blooms, qPCR analysis confirmed the presence of the STX-encoding gene sxtA at all lakes. In particular, the abundance of the sxtA gene had a strong positive correlation with STX concentrations in Big 11 Lake in Kansas City, which was also the site with the highest quantified STX concentration. Sequencing analysis revealed that potential STX producers, such as Aphanizomenon, Dolichospermum, and Raphidiopsis, were present. Further analysis targeting amplicons of the sxtA gene identified that Aphanizomenon and/or Dolichospermum are the primary STX producer, showing a significant correlation with sxtA gene abundances and STX concentrations. In addition, Aphanizomenon was associated with environmental factors, such as conductivity, sulfate, and orthophosphate, whereas Dolichospermum was correlated with temperature and pH. Overall, the results herein enhance our understanding of the STX-producing cyanobacteria and aid in developing strategies to control HCBs.
Collapse
Affiliation(s)
- Youchul Jeon
- Oak Ridge Institute for Science and Education, Oak Ridge, TN 37830, USA
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| | - Ian Struewing
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| | - Kyle McIntosh
- Oak Ridge Institute for Science and Education, Oak Ridge, TN 37830, USA
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| | - Marcie Tidd
- United States Environmental Protection Agency, Region 8, Lakewood, CO 80225, USA
| | - Laura Webb
- United States Environmental Protection Agency, Region 7, Kansas City, KS 66101, USA
| | - Hodon Ryu
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| | - Heath Mash
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| | - Jingrang Lu
- United States Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA
| |
Collapse
|
5
|
Xu L, Sigler A, Chernatynskaya A, Rasmussen L, Lu J, Sahle-Demessie E, Westenberg D, Yang H, Shi H. Study of Legionella pneumophila treatment with copper in drinking water by single cell-ICP-MS. Anal Bioanal Chem 2024; 416:419-430. [PMID: 37962610 DOI: 10.1007/s00216-023-05033-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/16/2023] [Accepted: 10/31/2023] [Indexed: 11/15/2023]
Abstract
Legionella pneumophila is a persistent opportunistic pathogen that poses a significant threat to domestic water systems. Previous studies suggest that copper (Cu) is an effective antimicrobial in water systems. A rapid and sensitive quantification method is desired to optimize the conditions of L. pneumophila treatment by Cu and to better understand the interaction mechanisms between Cu and cells. In this study, we developed a highly sensitive single cell (SC)-ICP-MS method to monitor L. pneumophila cell concentration and track their uptake of Cu. The SC-ICP-MS method showed excellent sensitivity (with a cell concentration detection limit of 1000 cells/mL), accuracy (good agreement with conventional hemocytometry method), and precision (relative standard deviation < 5%) in drinking water matrix. The cupric ions (Cu2+) treatment results indicated that the total L. pneumophila cell concentration, Cu mass per cell, colony-forming unit counting, and Cu concentration in supernatant all exhibited a dose-dependent trend, with 800-1200 µg/L reaching high disinfection rates in drinking water. The investigation of percentages of viable and culturable, viable but nonculturable (VBNC), and lysed cells suggested there always were VBNC present at any Cu concentration. Experimental results of different Cu2+ treatment times further suggested that L. pneumophila cells developed an antimicrobial resistant mechanism with the prolonged Cu exposure. This is the first quantification study on the interactions of Cu and L. pneumophila in drinking water using SC-ICP-MS.
Collapse
Affiliation(s)
- Lei Xu
- Linda and Bipin Doshi Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, Rolla, MO, 65409, USA
| | - Austin Sigler
- Department of Chemistry and Center for Research in Energy and Environment, Missouri University of Science and Technology, Rolla, MO, 65409, USA
| | - Anna Chernatynskaya
- Linda and Bipin Doshi Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, Rolla, MO, 65409, USA
| | - Lindsey Rasmussen
- Department of Chemistry and Center for Research in Energy and Environment, Missouri University of Science and Technology, Rolla, MO, 65409, USA
| | - Jingrang Lu
- Office of Research and Development, US Environmental Protection Agency, Cincinnati, OH, USA
| | | | - David Westenberg
- Department of Biological Sciences, Missouri University of Science and Technology, Rolla, MO, 65409, USA
| | - Hu Yang
- Linda and Bipin Doshi Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, Rolla, MO, 65409, USA.
| | - Honglan Shi
- Department of Chemistry and Center for Research in Energy and Environment, Missouri University of Science and Technology, Rolla, MO, 65409, USA.
| |
Collapse
|
6
|
Chochlakis D, Sandalakis V, Ntoukakis A, Daskalaki MO, Loppinet T, Thalassinaki N, Makridaki R, Panoulis C, Psaroulaki A. Multi-criterion analysis of the effect of physico-chemical microbiological agents on Legionella detection in hotel water distribution systems in Crete. Front Cell Infect Microbiol 2023; 13:1214717. [PMID: 38188625 PMCID: PMC10770838 DOI: 10.3389/fcimb.2023.1214717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2023] [Accepted: 10/17/2023] [Indexed: 01/09/2024] Open
Abstract
Introduction Water distribution systems in hotels have been related to outbreaks caused by Legionella spp. Certain measures, including disinfection by chlorination, maintaining increased temperatures are usually undertaken to prevent Legionella outbreaks. However, these preventive strategies are not always effective, since there are several factors (e.g., synergistic interactions with other microbes, physico-chemical factors, biofilm formation, availability of nutrients) that promote survival and proliferation of the pathogen in water pipes., Accordingly, there is a need of a holistic approach in development of preventive models for Legionella outbreaks associated with water distribution systems. Methods Water samples were collected from hotel water systems and were tested for the presence of Legionella, E. coli, total coliforms, total mesophilic count and Pseudomonas. In each sample, temperature and chlorine were also tested. Other epidemiological factors were additionally recorded including number of rooms, stars, proximity of sampling point to the boiler, etc. Data were processed by generalized linear analysis, and modeling based on logistic regression analysis to identify independent predictive factors associated with the presence of Legionella in hotel water systems. Results According to the generalized linear model, temperature affected (p<0.05) the presence of Legionella regardless of the species or the water supply (hot or cold). Additionally, opportunistic (P. aeruginosa) or non-opportunistic (E. coli, coliforms) pathogens were significantly associated (p<0.05) with the presence of all Legionella species. Temperature also exhibited a positive effect to all pathogens tested except for Pseudomonas according to the linear model. Multivariate analysis showed that Pseudomonas, total coliforms, HPC and temperature had a statistically significant effect on the presence of Legionella. Based on a binomial model, cold water had a positive effect on Legionella. Type of sampling and proximity of the sample to the boiler seemed to pose different effect on Legionella depending on the cfu/L. The number of hotel stars and rooms did not appear to have any effect in all tested models. Discussion Collectively, these results indicate the need for development of individualized water safety plans tailored by the presence of other microbiological agents, and unique physico-chemical factors, which could facilitate the survival of Legionella.in hotel water systems.
Collapse
Affiliation(s)
- Dimosthenis Chochlakis
- Regional Laboratory of Public Health of Crete, School of Medicine, University of Crete, Heraklion, Greece
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Vassilios Sandalakis
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Apostolos Ntoukakis
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Maria-Olga Daskalaki
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Thomas Loppinet
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Niki Thalassinaki
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Rena Makridaki
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Christos Panoulis
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| | - Anna Psaroulaki
- Regional Laboratory of Public Health of Crete, School of Medicine, University of Crete, Heraklion, Greece
- Laboratory of Clinical Microbiology and Microbial Pathogenesis, School of Medicine, University of Crete, Heraklion, Greece
| |
Collapse
|
7
|
Song X, Zhang G, Zhou Y, Li W. Behaviors and mechanisms of microbially-induced corrosion in metal-based water supply pipelines: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 895:165034. [PMID: 37355127 DOI: 10.1016/j.scitotenv.2023.165034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/14/2023] [Accepted: 06/18/2023] [Indexed: 06/26/2023]
Abstract
Microbially-induced corrosion (MIC) is unstoppable and extensively spread throughout drinking water distribution systems (DWDSs) as the cause of pipe leakage and deteriorating water quality. For maintaining drinking water safety and reducing capital inputs in pipe usage, the possible consequences from MIC in DWDSs is still a research hotspot. Although most studies have investigated the effects of changing environmental factors on MIC corrosion, the occurrence of MIC in DWDSs has not been discussed sufficiently. This review aims to fill this gap by proposing that the formation of deposits with microbial capture may be a source of MIC in newly constructed DWDSs. The microbes early attaching to the rough pipe surface, followed by chemically and microbially-induced mineral deposits which confers resistance to disinfectants is ascribed as the first step of MIC occurrence. MIC is then activated in the newly-built, viable, and accessible microenvironment while producing extracellular polymers. With longer pipe service, oligotrophic microbes slowly grow, and metal pipe materials gradually dissolve synchronously with electron release to microbes, resulting in pipe-wall damage. Different corrosive microorganisms using pipe material as a reaction substrate would directly or indirectly cause different types of corrosion. Correspondingly, the formation of scale layers may reflect the distribution of microbial species and possibly biogenic products. It is therefore assumed that the porous and loose layer is an ideal microbial-survival environment, capable of providing diverse and sufficient ecological niches. The usage and chelation of metabolic activities and metabolites, such as acetic, oxalic, citric and glutaric acids, may lead to the formation of a porous scale layer. Therefore, the microbial interactions within the pipe scale reinforce the stability of microbial communities and accelerate MIC. Finally, a schematic model of the MIC process is presented to interpret MIC from its onset to completion.
Collapse
Affiliation(s)
- Xin Song
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Guosheng Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yu Zhou
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Weiying Li
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
8
|
Cambronne ED, Ayres C, Dowdell KS, Lawler DF, Saleh NB, Kirisits MJ. Protozoan-Priming and Magnesium Conditioning Enhance Legionella pneumophila Dissemination and Monochloramine Resistance. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:14871-14880. [PMID: 37756220 DOI: 10.1021/acs.est.3c04013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Opportunistic pathogens (OPs) are of concern in drinking water distribution systems because they persist despite disinfectant residuals. While many OPs garner protection from disinfectants via a biofilm lifestyle, Legionella pneumophila (Lp) also gains disinfection resistance by being harbored within free-living amoebae (FLA). It has been long established, but poorly understood, that Lp grown within FLA show increased infectivity toward subsequent FLA or human cells (i.e., macrophage), via a process we previously coined "protozoan-priming". The objectives of this study are (i) to identify in Lp a key genetic determinant of how protozoan-priming increases its infectivity, (ii) to determine the chemical stimulus within FLA to which Lp responds during protozoan-priming, and (iii) to determine if more infectious forms of Lp also exhibit enhanced disinfectant resistance. Using Acanthamoeba castellanii as a FLA host, the priming effect was isolated to Lp's sidGV locus, which is activated upon sensing elevated magnesium concentrations. Supplementing growth medium with 8 mM magnesium is sufficient to produce Lp grown in vitro with an infectivity equivalent to that of Lp grown via the protozoan-primed route. Both Lp forms with increased infectivity (FLA-grown and Mg2+-supplemented) exhibit greater monochloramine resistance than Lp grown in standard media, indicating that passage through FLA not only increases Lp's infectivity but also enhances its monochloramine resistance. Therefore, laboratory-based testing of disinfection strategies should employ conditions that simulate or replicate intracellular growth to accurately assess disinfectant resistance.
Collapse
Affiliation(s)
- Eric D Cambronne
- Department of Molecular Biosciences, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Craig Ayres
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Katherine S Dowdell
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Desmond F Lawler
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Navid B Saleh
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| | - Mary Jo Kirisits
- Department of Civil, Architectural and Environmental Engineering, The University of Texas at Austin, Austin, Texas 78712, United States
| |
Collapse
|
9
|
Hu D, Li X, Zeng J, Xiao X, Zhao W, Zhang J, Yu X. Hidden risks: Simulated leakage of domestic sewage to secondary water supply systems poses serious microbiological risks. WATER RESEARCH 2023; 244:120529. [PMID: 37666151 DOI: 10.1016/j.watres.2023.120529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 08/22/2023] [Accepted: 08/25/2023] [Indexed: 09/06/2023]
Abstract
There are continuous reports about the pollution of the secondary water supply systems (SWSSs), among which domestic sewage leakage is the most serious. In this study, a pilot experiment lasting 70 days was conducted to explore the changes in physicochemical water quality and the microbial profiles in SWSSs polluted by different doses of domestic sewage through qPCR and high-throughput sequencing methods. The results showed that when domestic sewage entered the simulated water storage tank, a large amount of organic matter brought by domestic sewage quickly consumed chlorine disinfectants. High pollution levels (pollution index ≥ 1/1000) were accompanied by significant increases in turbidity and ammonia nitrogen concentration (p < 0.05) and by abnormal changes in sensory properties. Although different microbial community structures were found only at high pollution levels, qPCR results showed that the abundance of the bacterial 16S rRNA gene and some pathogenic gene markers in the polluted tank increased with the pollution level, and the specific gene marker of pathogens could be detected even at imperceptible pollution levels. In particular, the high detection frequency and abundance of Escherichia coli and Enterococcus faecails in polluted tank water samples demonstrated that they can be used for early warning. Moreover, it seems that the microorganisms that came with the domestic sewage lost their cultivability soon after entering SWSSs but could recover their activities during stagnation. In addition, the biofilm biomass in the polluted tank with high pollution levels increased faster at the initial stage, while after a longer contact time, it tended to remain at the same level as the control tank. This study emphasized the high microbial risk introduced by sewage water leakage even at imperceptible levels and could provide scientific suggestions for early warning and prevention of pollution to SWSSs.
Collapse
Affiliation(s)
- Dong Hu
- School of Public Health, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250117, China
| | - Xiang Li
- School of Public Health, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250117, China
| | - Jie Zeng
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| | - Xinyan Xiao
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Wenya Zhao
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Jiakang Zhang
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
10
|
Ke Y, Sun W, Chen X, Zhu Y, Guo X, Yan W, Xie S. Seasonality Determines the Variations of Biofilm Microbiome and Antibiotic Resistome in a Pilot-Scale Chlorinated Drinking Water Distribution System Deciphered by Metagenome Assembly. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:11430-11441. [PMID: 37478472 DOI: 10.1021/acs.est.3c01980] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/23/2023]
Abstract
Understanding the biofilm microbiome and antibiotic resistome evolution in drinking water distribution systems (DWDSs) is crucial to ensure the safety of drinking water. We explored the 10 month evolution of the microbial community, antibiotic resistance genes (ARGs), mobile gene elements (MGEs) co-existing with ARGs and pathogenic ARG hosts, and the ARG driving factors in DWDS biofilms using metagenomics assembly. Sampling season was critical in determining the microbial community and antibiotic resistome shift. Pseudomonas was the primary biofilm colonizer, and biofilms diversified more as the formation time increased. Most genera tended to cooperate to adapt to an oligotrophic environment with disinfectant stress. Biofilm microbial community and antibiotic resistome assembly were mainly determined by stochastic processes and changed with season. Metagenome assembly provided the occurrence and fates of MGEs co-existing with ARGs and ARG hosts in DWDS biofilms. The abundance of ARG- and MGE-carrying pathogen Stenotrophomonas maltophilia was high in summer. It primarily harbored the aph(3)-IIb, multidrug transporter, smeD, and metallo-beta-lactamase ARGs, which were transferred via recombination. The microbial community was the most crucial factor driving the antibiotic resistance shift. We provide novel insights about the evolution of pathogens and ARGs and their correlations in DWDS biofilms to ensure the safety of drinking water.
Collapse
Affiliation(s)
- Yanchu Ke
- School of Environment, Tsinghua University, Beijing 100084, China
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
| | - Xiuli Chen
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Ying Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Xu Guo
- Fangshan District Water Bureau, Beijing 102445, China
| | - Weixin Yan
- Beijing BiSheng United Water Company, Beijing 102400, China
| | - Shuguang Xie
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
11
|
Zhang C, McIntosh KD, Sienkiewicz N, Stelzer EA, Graham JL, Lu J. Using cyanobacteria and other phytoplankton to assess trophic conditions: A qPCR-based, multi-year study in twelve large rivers across the United States. WATER RESEARCH 2023; 235:119679. [PMID: 37011576 PMCID: PMC10123349 DOI: 10.1016/j.watres.2023.119679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 01/24/2023] [Accepted: 01/27/2023] [Indexed: 06/19/2023]
Abstract
Phytoplankton is the essential primary producer in fresh surface water ecosystems. However, excessive phytoplankton growth due to eutrophication significantly threatens ecologic, economic, and public health. Therefore, phytoplankton identification and quantification are essential to understanding the productivity and health of freshwater ecosystems as well as the impacts of phytoplankton overgrowth (such as Cyanobacterial blooms) on public health. Microscopy is the gold standard for phytoplankton assessment but is time-consuming, has low throughput, and requires rich experience in phytoplankton morphology. Quantitative polymerase chain reaction (qPCR) is accurate and straightforward with high throughput. In addition, qPCR does not require expertise in phytoplankton morphology. Therefore, qPCR can be a useful alternative for molecular identification and enumeration of phytoplankton. Nonetheless, a comprehensive study is missing which evaluates and compares the feasibility of using qPCR and microscopy to assess phytoplankton in fresh water. This study 1) compared the performance of qPCR and microscopy in identifying and quantifying phytoplankton and 2) evaluated qPCR as a molecular tool to assess phytoplankton and indicate eutrophication. We assessed phytoplankton using both qPCR and microscopy in twelve large freshwater rivers across the United States from early summer to late fall in 2017, 2018, and 2019. qPCR- and microscope-based phytoplankton abundance had a significant positive linear correlation (adjusted R2 = 0.836, p-value < 0.001). Phytoplankton abundance had limited temporal variation within each sampling season and over the three years studied. The sampling sites in the midcontinent rivers had higher phytoplankton abundance than those in the eastern and western rivers. For instance, the concentration (geometric mean) of Bacillariophyta, Cyanobacteria, Chlorophyta, and Dinoflagellates at the sampling sites in the midcontinent rivers was approximately three times that at the sampling sites in the western rivers and approximately 18 times that at the sampling sites in the eastern rivers. Welch's analysis of variance indicates that phytoplankton abundance at the sampling sites in the midcontinent rivers was significantly higher than that at the sampling sites in the eastern rivers (p-value = 0.013) but was comparable to that at the sampling sites in the western rivers (p-value = 0.095). The higher phytoplankton abundance at the sampling sites in the midcontinent rivers was presumably because these rivers were more eutrophic. Indeed, low phytoplankton abundance occurred in oligotrophic or low trophic sites, whereas eutrophic sites had greater phytoplankton abundance. This study demonstrates that qPCR-based phytoplankton abundance can be a useful numerical indicator of the trophic conditions and water quality in freshwater rivers.
Collapse
Affiliation(s)
- Chiqian Zhang
- Department of Civil and Environmental Engineering, College of Sciences and Engineering, Southern University and A&M College, Baton Rouge, LA 70813, United States
| | - Kyle D McIntosh
- Oak Ridge Institute for Science and Education at the United States Environmental Protection Agency's Office of Research and Development, Oak Ridge, TN 37830, United States
| | - Nathan Sienkiewicz
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States
| | - Erin A Stelzer
- U.S. Geological Survey, Columbus, OH 43229, United States
| | | | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, United States.
| |
Collapse
|
12
|
Aurass P, Kim S, Pinedo V, Cava F, Isberg RR. Identification of Genes Required for Long-Term Survival of Legionella pneumophila in Water. mSphere 2023; 8:e0045422. [PMID: 36988466 PMCID: PMC10117105 DOI: 10.1128/msphere.00454-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 02/24/2023] [Indexed: 03/30/2023] Open
Abstract
Long-term survival of Legionella pneumophila in aquatic environments is thought to be important for facilitating epidemic outbreaks. Eliminating bacterial colonization in plumbing systems is the primary strategy that depletes this reservoir and prevents disease. To uncover L. pneumophila determinants facilitating survival in water, a Tn-seq strategy was used to identify survival-defective mutants during 50-day starvation in tap water at 42°C. The mutants with the most drastic survival defects carried insertions in electron transport chain genes, indicating that membrane energy charge and/or ATP synthesis requires the generation of a proton gradient by the respiratory chain to maintain survival in the presence of water stress. In addition, periplasmically localized proteins that are known (EnhC) or hypothesized (lpg1697) to stabilize the cell wall against turnover were essential for water survival. To test that the identified mutations disrupted water survival, candidate genes were knocked down by CRISPRi. The vast majority of knockdown strains with verified transcript depletion showed remarkably low viability after 50-day incubations. To demonstrate that maintenance of cell wall integrity was an important survival determinant, a deletion mutation in lpg1697, in a gene encoding a predicted l,d-transpeptidase domain, was analyzed. The loss of this gene resulted in increased osmolar sensitivity and carbenicillin hypersensitivity relative to the wild type, as predicted for loss of an l,d-transpeptidase. These results indicate that the L. pneumophila envelope has been evolutionarily selected to allow survival under conditions in which the bacteria are subjected to long-term exposure to starvation and low osmolar conditions. IMPORTANCE Water is the primary vector for transmission of L. pneumophila to humans, and the pathogen is adapted to persist in this environment for extended periods of time. Preventing survival of L. pneumophila in water is therefore critical for prevention of Legionnaires' disease. We analyzed dense transposon mutation pools for strains with severe survival defects during a 50-day water incubation at 42°C. By tracking the associated transposon insertion sites in the genome, we defined a distinct essential gene set for water survival and demonstrate that a predicted peptidoglycan cross-linking enzyme, lpg1697, and components of the electron transport chain are required to ensure survival of the pathogen. Our results indicate that select characteristics of the cell wall and components of the respiratory chain of L. pneumophila are primary evolutionary targets being shaped to promote its survival in water.
Collapse
Affiliation(s)
- Philipp Aurass
- Department of Enteropathogenic Bacteria and Legionella, Robert Koch Institute, Wernigerode, Germany
- Department of Molecular Biology and Microbiology, Tufts University School of Medicine, Boston, Massachusetts, USA
| | - Seongok Kim
- Department of Molecular Biology and Microbiology, Tufts University School of Medicine, Boston, Massachusetts, USA
| | - Victor Pinedo
- Laboratory for Molecular Infection Medicine Sweden, Department of Molecular Biology, Umeå Centre for Microbial Research, Umeå University, Umeå, Sweden
| | - Felipe Cava
- Laboratory for Molecular Infection Medicine Sweden, Department of Molecular Biology, Umeå Centre for Microbial Research, Umeå University, Umeå, Sweden
| | - Ralph R. Isberg
- Department of Molecular Biology and Microbiology, Tufts University School of Medicine, Boston, Massachusetts, USA
| |
Collapse
|
13
|
Lombardi A, Borriello T, De Rosa E, Di Duca F, Sorrentino M, Torre I, Montuori P, Trama U, Pennino F. Environmental Monitoring of Legionella in Hospitals in the Campania Region: A 5-Year Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:ijerph20085526. [PMID: 37107807 PMCID: PMC10138562 DOI: 10.3390/ijerph20085526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/06/2023] [Accepted: 04/13/2023] [Indexed: 05/11/2023]
Abstract
Legionella is a pathogen that colonizes soils, freshwater, and building water systems. People who are most affected are those with immunodeficiencies, so it is necessary to monitor its presence in hospitals. The purpose of this study was to evaluate the presence of Legionella in water samples collected from hospitals in the Campania region, Southern Italy. A total of 3365 water samples were collected from January 2018 to December 2022 twice a year in hospital wards from taps and showers, tank bottoms, and air-treatment units. Microbiological analysis was conducted in accordance with the UNI EN ISO 11731:2017, and the correlations between the presence of Legionella and water temperature and residual chlorine were investigated. In total, 708 samples (21.0%) tested positive. The most represented species was L. pneumophila 2-14 (70.9%). The serogroups isolated were 1 (27.7%), 6 (24.5%), 8 (23.3%), 3 (18.9%), 5 (3.1%), and 10 (1.1%). Non-pneumophila Legionella spp. represented 1.4% of the total. Regarding temperature, the majority of Legionella positive samples were found in the temperature range of 26.0-40.9 °C. An influence of residual chlorine on the presence of the bacterium was observed, confirming that chlorine disinfection is effective for controlling contamination. The positivity for serogroups other than serogroup 1 suggested the need to continue environmental monitoring of Legionella and to focus on the clinical diagnosis of other serogroups.
Collapse
Affiliation(s)
- Annalisa Lombardi
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Tonia Borriello
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Elvira De Rosa
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Fabiana Di Duca
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Michele Sorrentino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ida Torre
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Paolo Montuori
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
| | - Ugo Trama
- General Directorate of Health, Campania Region, Centro Direzionale C3, 80143 Naples, Italy
| | - Francesca Pennino
- Department of Public Health, University “Federico II”, Via Sergio Pansini N° 5, 80131 Naples, Italy
- Correspondence:
| |
Collapse
|
14
|
Kim T, Zhao X, LaPara TM, Hozalski RM. Flushing Temporarily Improves Microbiological Water Quality for Buildings Supplied with Chloraminated Surface Water but Has Little Effect for Groundwater Supplies. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:5453-5463. [PMID: 36952669 DOI: 10.1021/acs.est.2c08123] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Microbial communities in premise plumbing systems were investigated after more than 2 months of long-term stagnation, during a subsequent flushing event, and during post-flush stagnation. Water samples were collected from showers in buildings supplied with chlorinated groundwater, untreated groundwater, and chloraminated surface water. The building supplied with chlorinated groundwater generally had the lowest bacterial concentrations across all sites (ranging from below quantification limit to 5.2 log copies/L). For buildings supplied with untreated groundwater, bacterial concentrations (5.0 to 7.6 log copies/L) and microbial community diversity index (ACE) values were consistent throughout sampling. Nontuberculous mycobacteria (NTM) and Legionella pneumophila were not detected in any groundwater-supplied buildings. Total bacteria, Legionella spp., and NTM were abundant in the surface water-supplied buildings following long-term stagnation (up to 7.6, 6.2, and 7.6 log copies/L, respectively). Flushing decreased these concentrations by ∼1 to >4 log units and reduced microbial community diversity, but the communities largely recovered within a week of post-flush stagnation. The results suggest that buildings supplied with disinfected surface water are more likely than buildings supplied with treated or untreated groundwater to experience deleterious changes in microbiological water quality during stagnation and that the water quality improvements from flushing with chloraminated water, while substantial, are short-lived.
Collapse
Affiliation(s)
- Taegyu Kim
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
- Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Avenue, St. Paul, Minnesota 55108, United States
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
- Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Avenue, St. Paul, Minnesota 55108, United States
| |
Collapse
|
15
|
Hu D, Zeng J, Chen J, Lin W, Xiao X, Feng M, Yu X. Microbiological quality of roof tank water in an urban village in southeastern China. J Environ Sci (China) 2023; 125:148-159. [PMID: 36375901 DOI: 10.1016/j.jes.2022.01.036] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/18/2022] [Accepted: 01/24/2022] [Indexed: 06/16/2023]
Abstract
Urban villages are unique residential neighborhoods in urban areas in China. Roof tanks are their main form of water supply, and water quality deterioration might occur in this system because of poor hygienic conditions and maintenance. In this study, water samples were seasonally collected from an urban village to investigate the influence of roof tanks as an additional water storage device on the variation in the microbial community structure and pathogenic gene markers. Water stagnation in the roof tank induced significant decreases in chlorine (p < 0.05), residual chlorine was as low as 0.02 mg/L in spring. Propidium monoazide (PMA)-qPCR revealed a one-magnitude higher level of total viable bacterial concentration in roof tank water samples (2.14 ± 1.81 × 105 gene copies/mL) than that in input water samples (3.57 ± 2.90 × 104 gene copies/mL, p < 0.05), especially in spring and summer. In addition, pathogenic fungi, Mycobacterium spp., and Legionella spp. were frequently detected in the roof tanks. Terminal users might be exposed to higher microbial risk induced by high abundance of Legionella gene marker. Spearman's rank correlation and redundancy analysis showed that residual chlorine was the driving force that promoted bacterial colonization and shaped the microbial community. It is worth noted that the sediment in the pipe will be agitated when the water supply is restored after the water outages, which can trigger an increase in turbidity and bacterial biomass. Overall, the findings provide practical suggestions for controlling microbiological health risks in roof tanks in urban villages.
Collapse
Affiliation(s)
- Dong Hu
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jie Zeng
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Jing Chen
- Shitang Community Health Service Center, Xiamen 361026, China
| | - Wenfang Lin
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Xinyan Xiao
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Mingbao Feng
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Xin Yu
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
16
|
Zhou Q, Huang J, Guo K, Lou Y, Wang H, Zhou R, Tang J, Hou P. Spatiotemporal distribution of opportunistic pathogens and microbial community in centralized rural drinking water: One year survey in China. ENVIRONMENTAL RESEARCH 2023; 218:115045. [PMID: 36513125 DOI: 10.1016/j.envres.2022.115045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 11/18/2022] [Accepted: 12/09/2022] [Indexed: 06/17/2023]
Abstract
Centralized water supply in rural areas, supported by small waterworks (small-central mode) and by municipal water treatment plants (urban-extension mode), is an important guarantee to implement the Rural Revitalization Strategy Plan (2018-2022) in China. Opportunistic pathogens (OPs) could not be evaluated by the national drinking water sanitation standards in China (GB 5749-2022), posing potential microbial risks in rural drinking water. In this study, the spatiotemporal distribution of OPs, microbial community and the associated functional composition under two central water supply modes were investigated by molecular approaches. The results indicated that OPs were widely presented in the rural drinking water regardless of water supply modes, and were more abundant than those in the urban tap water. The insufficient residual chlorine and higher turbidity triggered more microbial proliferation, posing a seasonal variation of OPs gene copy numbers and bacterial community compositions. In warm seasons of summer and autumn, the gene copies of E. coli, M. avium, Pseudomonas spp. and the amoeba host Acanthamoeba spp. achieved up to 4.92, 3.94, 6.75 and 3.74 log10 (gene copies/mL), respectively. Potential functional prediction indicated higher relative abundance of pathogenic genes and infectious risks associated with the rural drinking water under small-central water supply mode. This one-year survey of the spatiotemporal distribution of OPs and microbial community provided scientific insights into microbial safety of rural drinking water, prompting attention on small-central water supply mode against OPs risks.
Collapse
Affiliation(s)
- Qiaomei Zhou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China.
| | - Jingang Huang
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China; The Belt and Road Information Research Institute, Hangzhou Dianzi University, Hangzhou, 310018, PR China.
| | - Kangyin Guo
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China; Zhejiang Sunrise Garment Group Co., Ltd., Shengzhou, 312400, PR China
| | - Yucheng Lou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China.
| | - Rongbing Zhou
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Junhong Tang
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Pingzhi Hou
- The Belt and Road Information Research Institute, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| |
Collapse
|
17
|
Molina JJ, Bennassar M, Palacio E, Crespi S. Impact of prolonged hotel closures during the COVID-19 pandemic on Legionella infection risks. Front Microbiol 2023; 14:1136668. [PMID: 36910223 PMCID: PMC9998907 DOI: 10.3389/fmicb.2023.1136668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 02/10/2023] [Indexed: 03/14/2023] Open
Abstract
In general, it is accepted that water stagnation and lack or poor maintenance in buildings are risk factors for Legionella growth. Then, in theory, the prolonged hotel closures due to the COVID-19 pandemic may have increased the risk of Legionella infections. However, there are very few field studies comparing the level of Legionella colonization in buildings before the pandemic and the new situation created after the lockdown. The objective of this study was to analyze these differences in a group of hotels that experienced prolonged closures in 2020 due to the COVID-19 pandemic. We have studied the Legionella spp. results, analyzed by standard culture, from the domestic water distribution systems of 73 hotels that experienced closures (from 1 to >4 months) during 2020, immediately after the reopening. The results were compared with those obtained in similar samplings of 2019. For the comparative analysis, we divided the hotels in two groups: Group A that have suffered closures for ≤3 months and Group B that remained closed for more than 3 months, both in relation to the opening period of 2019. In the Group B (36 sites), the frequency of positive samples in the hot water system increased from 6.7% in 2019 to 14.0% in 2020 (p < 0.05). In the Group A (37 sites), no significant differences were observed. No statistically significant differences were observed in terms of positive sites (defined as hotels with at least 1 positive sample), Legionella spp. concentrations and prevalence of Legionella pneumophila sg1 between the samplings of the two periods studied. The results suggest that hotels that suffered the longest prolonged closures (> 3 months) could have carried a higher risk of exposure to Legionella in the domestic hot water system. These findings highlight the importance of adequate preopening cleaning and disinfection procedures for hotel water systems, and the convenience of considering the most effective disinfection methods especially for hot water systems and after prolonged closure periods.
Collapse
Affiliation(s)
- Jhon J Molina
- Environmental Health and Laboratory Services, Biolinea Int., Palma, Spain.,Environmental Analytical Chemistry Laboratory, Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | | | - Edwin Palacio
- Environmental Analytical Chemistry Laboratory, Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Sebastian Crespi
- Environmental Health and Laboratory Services, Biolinea Int., Palma, Spain
| |
Collapse
|
18
|
Abulikemu G, Mistry JH, Wahman DG, Alexander MT, Kennicutt AR, Bollman JD, Pressman JG. Investigation of Chloramines, Disinfection Byproducts, and Nitrification in Chloraminated Drinking Water Distribution Systems. JOURNAL OF ENVIRONMENTAL ENGINEERING (NEW YORK, N.Y.) 2022; 149:1-12. [PMID: 37593338 PMCID: PMC10430769 DOI: 10.1061/(asce)ee.1943-7870.0002062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 06/11/2022] [Indexed: 08/19/2023]
Abstract
Four chloraminated drinking water distribution systems (CDWDSs) required to maintain numeric versus "detectable" residuals were spatially and temporally sampled for water quality and associated trihalomethane (THM) and haloacetic acid (HAA) formation. Monochloramine decreased from entry point (EP) to maximum residence time (MRT) samples while THMs and HAAs initially increased and then stabilized or slightly decreased. Subsequently, EP and MRT samples were used in laboratory-held studies to further evaluate disinfectant residual stability, chloramine speciation, and nitrification occurrence. MRT water exhibited a faster monochloramine concentration decline compared to EP water, indicating a decreasing disinfectant residual stability from increasing water age through distribution. Using a simple technique based on published inorganic chloramine chemistry, samples were also investigated for nondisinfectant positive interference (NDPI) on total chlorine measurements. NDPI concentrations represented up to 100% of the total chlorine concentration when total chlorine concentrations decreased to 0.05 mg-Cl2/L, indicating little to no effective disinfectant residual remained.
Collapse
Affiliation(s)
- Gulizhaer Abulikemu
- Pegasus Technical Services, Inc., 46 E Hollister St., Cincinnati, OH 45219; Graduate Student, College of Engineering and Applied Science, Univ. of Cincinnati, Cincinnati, OH 45221
| | - Jatin H Mistry
- Region 6, US Environmental Protection Agency, Dallas, TX 75270
| | - David G Wahman
- Center for Environmental Solutions and Emergency Response, US Environmental Protection Agency, Cincinnati, OH 45268
| | - Matthew T Alexander
- Technical Support Center, US Environmental Protection Agency, Cincinnati, OH 45268
| | - Alison R Kennicutt
- National Research Council Research Associateship Programs, Washington, DC 20001; presently, Assistant Professor, Dept. of Civil and Mechanical Engineering, York College of Pennsylvania, York, PA 17403
| | - Jacob D Bollman
- College of Engineering and Applied Science, Univ. of Cincinnati, Cincinnati, OH 45221; presently, Process Engineer, DuPont, 8480 DuPont Rd., Parkersburg, WV 26101
| | - Jonathan G Pressman
- Center for Environmental Solutions and Emergency Response, US Environmental Protection Agency, Cincinnati, OH 45268; mailing address: USEPA, 26 W. Martin Luther King Dr., Cincinnati, OH 45268
| |
Collapse
|
19
|
Zeng H, Cheng Y, Repo E, Yu X, Xing X, Zhang T, Zhao X. Trace Iron as single-electron shuttle for interdependent activation of peroxydisulfate and HSO 3-/O 2 enables accelerated generation of radicals. WATER RESEARCH 2022; 223:118935. [PMID: 35994783 DOI: 10.1016/j.watres.2022.118935] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/16/2022] [Accepted: 08/01/2022] [Indexed: 06/15/2023]
Abstract
The generation of reactive oxygen species generally requires initiators in various environmental remediation processes, which necessitates high dosage of activators and downstream treatment for eliminating the accumulation of deactivated catalysts. Herein, a coupled process was constructed using trace iron for simultaneously activating HSO3-/O2 system and peroxydisulfate (PDS) oxidation system, where the iron ions (2 mg/L) transferred single-electron from the former system to the latter due to the moderate redox potential (Fe3+/Fe2+, +0.77 V) between the potentials of SO3·-/HSO3- (+0.63 V) and PDS/SO4·- (+2.01 V). Hence, the phenol degradation quickly occurred at a first-order kinetic constant of k1=0.223 min-1 due to the accelerated generation of sulfate radical (SO4·-) and hydroxyl radical (·OH) in the process. The k1 value was almost 6-fold of that in the deoxygenated condition (0.040 min-1). Density function theory reveals that the single electron shuttle spatially separates the electron-donating activation of HSO3- and electron-accepting activation of PDS, while avoiding the "mutual-annihilation" of HSO3- and S2O82- via direct two-electron transfer. Finally, utilizing the in-situ generated electron-shuttle (dissolved iron from cast iron pipe), the HSO3-/PDS reagent could efficiently inactivate the chlorine-resistant pathogens and inhibits biofilm regrowth inside the distribution systems at regular intervals or infectious disease outbreak in a neighborhood.
Collapse
Affiliation(s)
- Huabin Zeng
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, PR China; Department of Separation Science, School of Engineering Science, Lappeenranta-Lahti University of Technology LUT, Mikkeli, FI 50130, Finland
| | - Yue Cheng
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, PR China
| | - Eveliina Repo
- Department of Separation Science, School of Engineering Science, Lappeenranta-Lahti University of Technology LUT, Mikkeli, FI 50130, Finland
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, PR China
| | - Xueci Xing
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China.
| | - Tao Zhang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Xu Zhao
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| |
Collapse
|
20
|
Duan X, Zhang C, Struewing I, Li X, Allen J, Lu J. Cyanotoxin-encoding genes as powerful predictors of cyanotoxin production during harmful cyanobacterial blooms in an inland freshwater lake: Evaluating a novel early-warning system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 830:154568. [PMID: 35302035 PMCID: PMC9698223 DOI: 10.1016/j.scitotenv.2022.154568] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 02/26/2022] [Accepted: 03/10/2022] [Indexed: 05/06/2023]
Abstract
Freshwater harmful cyanobacterial blooms (HCBs) potentially produce excessive cyanotoxins, mainly microcystins (MCs), significantly threatening aquatic ecosystems and public health. Accurately predicting HCBs is thus essential to developing effective HCB mitigation and prevention strategies. We previously developed a novel early-warning system that uses cyanotoxin-encoding genes to predict cyanotoxin production in Harsha Lake, Ohio, USA, in 2015. In this study, we evaluated the efficacy of the early-warning system in forecasting the 2016 HCB in the same lake. We also examined potential HCB drivers and cyanobacterial community composition. Our results revealed that the cyanobacterial community was stable at the phylum level but changed dynamically at the genus level over time. Microcystis and Planktothrix were the major MC-producing genera that thrived in June and July and produced high concentrations of MCs (peak level 10.22 μg·L-1). The abundances of the MC-encoding gene cluster mcy and its transcript levels significantly correlated with total MC concentrations (before the MC concentrations peaked) and accurately predicted MC production as revealed by logistic equations. When the Microcystis-specific gene mcyG reached approximately 1.5 × 103 copies·mL-1 or when its transcript level reached approximately 2.4 copies·mL-1, total MC level exceeded 0.3 μg L-1 (a health advisory limit) approximately one week later (weekly sampling scheme). This study suggested that cyanotoxin-encoding genes are promising predictors of MC production in inland freshwater lakes, such as Harsha Lake. The evaluated early-warning system can be a useful tool to assist lake managers in predicting, mitigating, and/or preventing HCBs.
Collapse
Affiliation(s)
- Xiaodi Duan
- Pegasus Technical Services, Inc., Cincinnati, OH 45219, USA
| | - Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH 45219, USA
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Xiang Li
- Oak Ridge Institute for Science and Education at the United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Joel Allen
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH 45268, USA.
| |
Collapse
|
21
|
Faucher SP, Matthews S, Nickzad A, Vounba P, Shetty D, Bédard É, Prévost M, Déziel E, Paranjape K. Toxoflavin secreted by Pseudomonas alcaliphila inhibits the growth of Legionella pneumophila and Vermamoeba vermiformis. WATER RESEARCH 2022; 216:118328. [PMID: 35364354 DOI: 10.1016/j.watres.2022.118328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 03/07/2022] [Accepted: 03/17/2022] [Indexed: 06/14/2023]
Abstract
Legionella pneumophila is a natural inhabitant of water systems. From there, it can be transmitted to humans by aerosolization resulting in severe pneumonia. Most large outbreaks are caused by cooling towers colonized with L. pneumophila. The resident microbiota of the cooling tower is a key determinant for the colonization and growth of L. pneumophila. In our preceding study, the genus Pseudomonas correlated negatively with the presence of L. pneumophila in cooling towers, but it was not clear which species was responsible. Therefore, we identified the Pseudomonas species inhabiting 14 cooling towers using a Pseudomonas-specific 16S rRNA amplicon sequencing strategy. We found that cooling towers that are free of L. pneumophila contained a high relative abundance of members from the Pseudomonas alcaliphila/oleovorans phylogenetic cluster. P. alcaliphila JCM 10630 inhibited the growth of L. pneumophila on agar plates. Analysis of the P. alcaliphila genome revealed the presence of a gene cluster predicted to produce toxoflavin. L. pneumophila growth was inhibited by pure toxoflavin and by extracts from P. alcaliphila culture found to contain toxoflavin by liquid chromatography coupled with mass spectrometry. In addition, toxoflavin inhibits the growth of Vermameoba vermiformis, a host cell of L. pneumophila. Our study indicates that P. alcaliphila may be important to restrict growth of L. pneumophila in water systems through the production of toxoflavin. A sufficiently high concentration of toxoflavin is likely not achieved in the bulk water but might have a local inhibitory effect such as near or in biofilms.
Collapse
Affiliation(s)
- Sebastien P Faucher
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Sara Matthews
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Arvin Nickzad
- Centre Armand-Frappier Santé Biotechnologie, Institut National de la Recherche Scientifique (INRS), Laval, QC, Canada
| | - Passoret Vounba
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Deeksha Shetty
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada
| | - Émilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Québec, Canada
| | - Michele Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, Québec, Canada
| | - Eric Déziel
- Centre Armand-Frappier Santé Biotechnologie, Institut National de la Recherche Scientifique (INRS), Laval, QC, Canada
| | - Kiran Paranjape
- Department of Natural Resource Sciences, Faculty of Agricultural and Environmental Sciences, McGill University, Sainte-Anne-de-Bellevue, QC, Canada; Department of Medical Biochemistry and Microbiology, Uppsala University, Uppsala, Sweden
| |
Collapse
|
22
|
Wang C, Ye Q, Zhang J, Pang R, Gu Q, Ding Y, Wu Q, Wang J. Multiplex PCR identification of the major Pseudomonas aeruginosa serogroups using specific novel target genes. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2022.113567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
23
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
- Correspondence: Jingrang Lu,
| |
Collapse
|