1
|
Mansor MA, Ahmad MR, Petrů M, Rahimian Koloor SS. An impedance flow cytometry with integrated dual microneedle for electrical properties characterization of single cell. ARTIFICIAL CELLS, NANOMEDICINE, AND BIOTECHNOLOGY 2023; 51:371-383. [PMID: 37548425 DOI: 10.1080/21691401.2023.2239274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/10/2023] [Accepted: 07/12/2023] [Indexed: 08/08/2023]
Abstract
Electrical characteristics of living cells have been proven to reveal important details about their internal structure, charge distribution and composition changes in the cell membrane, as well as the extracellular context. An impedance flow cytometry is a common approach to determine the electrical properties of a cell, having the advantage of label-free and high throughput. However, the current techniques are complex and costly for the fabrication process. For that reason, we introduce an integrated dual microneedle-microchannel for single-cell detection and electrical properties extraction. The dual microneedles utilized a commercially available tungsten needle coated with parylene. When a single cell flows through the parallel-facing electrode configuration of the dual microneedle, the electrical impedance at multiple frequencies is measured. The impedance measurement demonstrated the differential of normal red blood cells (RBCs) with three different sizes of microbeads at low and high frequencies, 100 kHz and 2 MHz, respectively. An electrical equivalent circuit model (ECM) was used to determine the unique membrane capacitance of individual cells. The proposed technique demonstrated that the specific membrane capacitance of an RBC is 9.42 mF/m-2, with the regression coefficients, ρ at 0.9895. As a result, this device may potentially be used in developing countries for low-cost single-cell screening and detection.
Collapse
Affiliation(s)
- Muhammad Asraf Mansor
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia
| | - Mohd Ridzuan Ahmad
- Department of Control and Mechatronics Engineering, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia
| | - Michal Petrů
- Faculty of Mechanical Engineering, Technical University of Liberec, Liberec, Czech Republic
| | - Seyed Saeid Rahimian Koloor
- Institute for Nanomaterials, Advanced Technologies and Innovation, Technical University of Liberec, Liberec, Czech Republic
| |
Collapse
|
2
|
Tang T, Julian T, Ma D, Yang Y, Li M, Hosokawa Y, Yalikun Y. A review on intelligent impedance cytometry systems: Development, applications and advances. Anal Chim Acta 2023; 1269:341424. [PMID: 37290859 DOI: 10.1016/j.aca.2023.341424] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 05/22/2023] [Accepted: 05/23/2023] [Indexed: 06/10/2023]
Abstract
Impedance cytometry is a well-established technique for counting and analyzing single cells, with several advantages, such as convenience, high throughput, and no labeling required. A typical experiment consists of the following steps: single-cell measurement, signal processing, data calibration, and particle subtype identification. At the beginning of this article, we compared commercial and self-developed options extensively and provided references for developing reliable detection systems, which are necessary for cell measurement. Then, a number of typical impedance metrics and their relationships to biophysical properties of cells were analyzed with respect to the impedance signal analysis. Given the rapid advances of intelligent impedance cytometry in the past decade, this article also discussed the development of representative machine learning-based approaches and systems, and their applications in data calibration and particle identification. Finally, the remaining challenges facing the field were summarized, and potential future directions for each step of impedance detection were discussed.
Collapse
Affiliation(s)
- Tao Tang
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan; Department of Biomedical Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore, 117583, Singapore
| | - Trisna Julian
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan
| | - Doudou Ma
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Yang Yang
- Institute of Deep-Sea Science and Engineering, Chinese Academy of Sciences, Sanya, Hainan, 572000, PR China
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, 2109, Australia
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayamacho, Ikoma, Nara, 630-0192, Japan; Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
3
|
Iyer V, Issadore DA, Aflatouni F. The next generation of hybrid microfluidic/integrated circuit chips: recent and upcoming advances in high-speed, high-throughput, and multifunctional lab-on-IC systems. LAB ON A CHIP 2023; 23:2553-2576. [PMID: 37114950 DOI: 10.1039/d2lc01163h] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Since the field's inception, pioneers in microfluidics have made significant progress towards realizing complete lab-on-chip systems capable of sophisticated sample analysis and processing. One avenue towards this goal has been to join forces with the related field of microelectronics, using integrated circuits (ICs) to perform on-chip actuation and sensing. While early demonstrations focused on using microfluidic-IC hybrid chips to miniaturize benchtop instruments, steady advancements in the field have enabled a new generation of devices that expand past miniaturization into high-performance applications that would not be possible without IC hybrid integration. In this review, we identify recent examples of labs-on-chip that use high-resolution, high-speed, and multifunctional electronic and photonic chips to expand the capabilities of conventional sample analysis. We focus on three particularly active areas: a) high-throughput integrated flow cytometers; b) large-scale microelectrode arrays for stimulation and multimodal sensing of cells over a wide field of view; c) high-speed biosensors for studying molecules with high temporal resolution. We also discuss recent advancements in IC technology, including on-chip data processing techniques and lens-free optics based on integrated photonics, that are poised to further advance microfluidic-IC hybrid chips.
Collapse
Affiliation(s)
- Vasant Iyer
- Department of Electrical and Systems Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| | - David A Issadore
- Department of Electrical and Systems Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Bioengineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Firooz Aflatouni
- Department of Electrical and Systems Engineering, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
| |
Collapse
|
4
|
Bounik R, Cardes F, Ulusan H, Modena MM, Hierlemann A. Impedance Imaging of Cells and Tissues: Design and Applications. BME FRONTIERS 2022; 2022:1-21. [PMID: 35761901 PMCID: PMC7612906 DOI: 10.34133/2022/9857485] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Accepted: 03/28/2022] [Indexed: 11/09/2022] Open
Abstract
Due to their label-free and noninvasive nature, impedance measurements have attracted increasing interest in biological research. Advances in microfabrication and integrated-circuit technology have opened a route to using large-scale microelectrode arrays for real-time, high-spatiotemporal-resolution impedance measurements of biological samples. In this review, we discuss different methods and applications of measuring impedance for cell and tissue analysis with a focus on impedance imaging with microelectrode arrays in in vitro applications. We first introduce how electrode configurations and the frequency range of the impedance analysis determine the information that can be extracted. We then delve into relevant circuit topologies that can be used to implement impedance measurements and their characteristic features, such as resolution and data-acquisition time. Afterwards, we detail design considerations for the implementation of new impedance-imaging devices. We conclude by discussing future fields of application of impedance imaging in biomedical research, in particular applications where optical imaging is not possible, such as monitoring of ex vivo tissue slices or microelectrode-based brain implants.
Collapse
Affiliation(s)
- Raziyeh Bounik
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| | - Fernando Cardes
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| | - Hasan Ulusan
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| | - Mario M. Modena
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| | - Andreas Hierlemann
- ETH Zürich, Department of Biosystems Science and Engineering, Basel, Switzerland
| |
Collapse
|
5
|
Farooq A, Hayat F, Zafar S, Butt NZ. Thin flexible lab-on-a-film for impedimetric sensing in biomedical applications. Sci Rep 2022; 12:1066. [PMID: 35058505 PMCID: PMC8776742 DOI: 10.1038/s41598-022-04917-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Accepted: 12/15/2021] [Indexed: 11/10/2022] Open
Abstract
AbstractMicrofluidic cytometers based on coulter principle have recently shown a great potential for point of care biosensors for medical diagnostics. Here, we explore the design of an impedimetric microfluidic cytometer on flexible substrate. Two coplanar microfluidic geometries are compared to highlight the sensitivity of the device to the microelectrode positions relative to the detection volume. We show that the microelectrodes surface area and the geometry of the sensing volume for the cells strongly influence the output response of the sensor. Reducing the sensing volume decreases the pulse width but increases the overall pulse amplitude with an enhanced signal-to-noise ratio (~ max. SNR = 38.78 dB). For the proposed design, the SNR was adequate to enable good detection and differentiation of 10 µm diameter polystyrene beads and leukemia cells (~ 6–21 µm). Also, a systematic approach for irreversible & strong bond strength between the thin flexible surfaces that make up the biochip is explored in this work. We observed the changes in surface wettability due to various methods of surface treatment can be a valuable metric for determining bond strength. We observed permanent bonding between microelectrode defined polypropylene surface and microchannel carved PDMS due to polar/silanol groups formed by plasma treatment and consequent covalent crosslinking by amine groups. These experimental insights provide valuable design guidelines for enhancing the sensitivity of coulter based flexible lab-on-a-chip devices which have a wide range of applications in point of care diagnostics.
Collapse
|
6
|
Zhang Z, Huang X, Liu K, Lan T, Wang Z, Zhu Z. Recent Advances in Electrical Impedance Sensing Technology for Single-Cell Analysis. BIOSENSORS 2021; 11:470. [PMID: 34821686 PMCID: PMC8615761 DOI: 10.3390/bios11110470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 11/15/2021] [Accepted: 11/17/2021] [Indexed: 05/10/2023]
Abstract
Cellular heterogeneity is of significance in cell-based assays for life science, biomedicine and clinical diagnostics. Electrical impedance sensing technology has become a powerful tool, allowing for rapid, non-invasive, and label-free acquisition of electrical parameters of single cells. These electrical parameters, i.e., equivalent cell resistance, membrane capacitance and cytoplasm conductivity, are closely related to cellular biophysical properties and dynamic activities, such as size, morphology, membrane intactness, growth state, and proliferation. This review summarizes basic principles, analytical models and design concepts of single-cell impedance sensing devices, including impedance flow cytometry (IFC) to detect flow-through single cells and electrical impedance spectroscopy (EIS) to monitor immobilized single cells. Then, recent advances of both electrical impedance sensing systems applied in cell recognition, cell counting, viability detection, phenotypic assay, cell screening, and other cell detection are presented. Finally, prospects of impedance sensing technology in single-cell analysis are discussed.
Collapse
Affiliation(s)
- Zhao Zhang
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Sipailou 2, Nanjing 210018, China; (Z.Z.); (K.L.); (T.L.)
| | - Xiaowen Huang
- The First Affiliated Hospital of Nanjing Medical University (Jiangsu Province Hospital), Department of Orthopedics, Nanjing 210029, China;
| | - Ke Liu
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Sipailou 2, Nanjing 210018, China; (Z.Z.); (K.L.); (T.L.)
| | - Tiancong Lan
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Sipailou 2, Nanjing 210018, China; (Z.Z.); (K.L.); (T.L.)
| | - Zixin Wang
- School of Electronics and Information Technology, Sun Yat-Sen University, Xingang Xi Road 135, Guangzhou 510275, China;
| | - Zhen Zhu
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Sipailou 2, Nanjing 210018, China; (Z.Z.); (K.L.); (T.L.)
| |
Collapse
|
7
|
Ashley BK, Mukerji I, Hassan U. Investigating Cell-Particle Conjugate Orientations in a Microfluidic Channel to Ameliorate Impedance-based Signal Acquisition and Detection . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:7233-7236. [PMID: 34892768 PMCID: PMC8767423 DOI: 10.1109/embc46164.2021.9630171] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Many biomedical experimental assays rely on cell-to-microparticle conjugation and their subsequent detection to quantify disease-related biomarkers. In this report, we investigated the effect of particle attachment position on a cell's surface to a signal acquired using impedance cytometry. We also present a novel configuration of independent coplanar microelectrodes positioned at the bottom and top of the microfluidic channel. In simulation results, our configuration accurately identifies different particle positions around the cell. We implemented a channel design with focusing regions between electrodes, and considered external factors around the channel such as polydimethylsiloxane (PDMS) interacting with the electric field and physical constraints of top electrodes placed farther away from the channel which improves detection accuracy.
Collapse
|
8
|
Tang T, Liu X, Kiya R, Shen Y, Yuan Y, Zhang T, Suzuki K, Tanaka Y, Li M, Hosokawa Y, Yalikun Y. Microscopic impedance cytometry for quantifying single cell shape. Biosens Bioelectron 2021; 193:113521. [PMID: 34380102 DOI: 10.1016/j.bios.2021.113521] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/22/2021] [Accepted: 07/15/2021] [Indexed: 02/02/2023]
Abstract
In this work, we investigated the ability of impedance flow cytometry to measure the shape of single cells/particles. We found that the impedance pulses triggered by micro-objects that are asymmetric in morphology show a tilting trend, and there is no such a tilting trend for symmetric ones. Therefore, we proposed a new metric, tilt index, to quantify the tilt level of the impedance pulses. Through simulation, we found that the value of tilt index tends to be zero for perfectly symmetrical objects, while the value is greater than zero for asymmetrical ones. Also, this metric was found to be independent on the trajectories (i.e., lateral, and z-direction shift) of the target micro-object. In experiments, we adopted a home-made lock-in amplifier and performed experiments on 10 μm polystyrene beads and Euglena gracilis (E. gracilis) cells with varying shapes. The experimental results coincided with the simulation results and demonstrated that the new metric (tilt index) enables the impedance cytometry to characterize the shape single cells/particles without microscopy or other optical setups.
Collapse
Affiliation(s)
- Tao Tang
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan
| | - Xun Liu
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan
| | - Ryota Kiya
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan
| | - Yigang Shen
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka Suita, Osaka, 565-0871, Japan
| | - Yapeng Yuan
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka Suita, Osaka, 565-0871, Japan
| | - Tianlong Zhang
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan; School of Engineering, Macquarie University, Sydney, 2109, Australia
| | | | - Yo Tanaka
- Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka Suita, Osaka, 565-0871, Japan
| | - Ming Li
- School of Engineering, Macquarie University, Sydney, 2109, Australia
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, 8916-5 Takayama-cho Ikoma, Nara, 630-0192, Japan; Center for Biosystems Dynamics Research (BDR), RIKEN, 1-3 Yamadaoka Suita, Osaka, 565-0871, Japan.
| |
Collapse
|
9
|
On the Wireless Microwave Sensing of Bacterial Membrane Potential in Microfluidic-Actuated Platforms. SENSORS 2021; 21:s21103420. [PMID: 34069045 PMCID: PMC8156227 DOI: 10.3390/s21103420] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/08/2021] [Accepted: 05/12/2021] [Indexed: 12/22/2022]
Abstract
The investigation of the electromagnetic properties of biological particles in microfluidic platforms may enable microwave wireless monitoring and interaction with the functional activity of microorganisms. Of high relevance are the action and membrane potentials as they are some of the most important parameters of living cells. In particular, the complex mechanisms of a cell’s action potential are comparable to the dynamics of bacterial membranes, and consequently focusing on the latter provides a simplified framework for advancing the current techniques and knowledge of general bacterial dynamics. In this work, we provide a theoretical analysis and experimental results on the microwave detection of microorganisms within a microfluidic-based platform for sensing the membrane potential of bacteria. The results further advance the state of microwave bacteria sensing and microfluidic control and their implications for measuring and interacting with cells and their membrane potentials, which is of great importance for developing new biotechnologically engineered systems and solutions.
Collapse
|
10
|
Zhong J, Yang D, Zhou Y, Liang M, Ai Y. Multi-frequency single cell electrical impedance measurement for label-free cell viability analysis. Analyst 2021; 146:1848-1858. [PMID: 33619511 DOI: 10.1039/d0an02476g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Cell viability is a physiological status connected to cell membrane integrity and cytoplasmic topography, which is profoundly important for fundamental biological research and practical biomedical applications. A conventional method for assessing cell viability is through cell staining analysis. However, cell staining involves laborious and complicated processing procedures and is normally cytotoxic. Intrinsic cellular phenotypes thus provide new avenues for measuring cell viability in a stain-free and non-toxic manner. In this work, we present a label-free non-destructive impedance-based approach for cell viability assessment by simultaneously characterizing multiple electrical cellular phenotypes in a high-throughput manner (>1000 cells per min). A novel concept called the complex opacity spectrum is introduced for improving the discrimination of live and dead cells. The analysis of the complex opacity spectrum leads to the discovery of two frequency ranges that are optimized for characterizing membranous and cytoplasmic electrical phenotypes. The present impedance-based approach has successfully discriminated between living and dead cells in two different experimental scenarios, including mixed living and dead cells in both homogenous and heterogeneous cell samples. This impedance-based single cell phenotyping technique provides highly accurate and consistent cell viability analysis, which has been validated by commercial fluorescence-based flow cytometry (∼1% difference) using heterogeneous cell samples. This label-free high-throughput cell viability analysis strategy will have broad applications in the field of biology and medicine.
Collapse
Affiliation(s)
- Jianwei Zhong
- Pillar of Engineering Product Development, Singapore University of Technology and Design, 8 Somapah Road, Singapore 487372, Singapore.
| | | | | | | | | |
Collapse
|
11
|
A Low-Power Stable Wideband Current Source for Acupuncture Point Skin Impedance Measurements. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:6650651. [PMID: 33505642 PMCID: PMC7806389 DOI: 10.1155/2021/6650651] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 12/10/2020] [Accepted: 12/24/2020] [Indexed: 11/24/2022]
Abstract
A low-power stable wideband current source for acupuncture point skin impedance measurements has been designed employing a differential architecture and negative feedback. The circuits extend bandwidth to 1 MHz, reducing harmonic distortion to 0.24% at 1 MHz. The output impedance is 37 MΩ at 100 kHz and 11 MΩ at 1 MHz. The stability of the output current of the current source when connected to different loads is below 0.1% at frequencies up to 500 kHz and increases to 0.74% at 1 MHz. The circuit was manufactured in a 0.13-μm CMOS technology and measured results are presented. The area of the current source is 0.09 mm2 and its consumption is 1.2 mW. It is intended for low-power acupuncture point skin impedance measurements.
Collapse
|
12
|
Honrado C, Bisegna P, Swami NS, Caselli F. Single-cell microfluidic impedance cytometry: from raw signals to cell phenotypes using data analytics. LAB ON A CHIP 2021; 21:22-54. [PMID: 33331376 PMCID: PMC7909465 DOI: 10.1039/d0lc00840k] [Citation(s) in RCA: 79] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The biophysical analysis of single-cells by microfluidic impedance cytometry is emerging as a label-free and high-throughput means to stratify the heterogeneity of cellular systems based on their electrophysiology. Emerging applications range from fundamental life-science and drug assessment research to point-of-care diagnostics and precision medicine. Recently, novel chip designs and data analytic strategies are laying the foundation for multiparametric cell characterization and subpopulation distinction, which are essential to understand biological function, follow disease progression and monitor cell behaviour in microsystems. In this tutorial review, we present a comparative survey of the approaches to elucidate cellular and subcellular features from impedance cytometry data, covering the related subjects of device design, data analytics (i.e., signal processing, dielectric modelling, population clustering), and phenotyping applications. We give special emphasis to the exciting recent developments of the technique (timeframe 2017-2020) and provide our perspective on future challenges and directions. Its synergistic application with microfluidic separation, sensor science and machine learning can form an essential toolkit for label-free quantification and isolation of subpopulations to stratify heterogeneous biosystems.
Collapse
Affiliation(s)
- Carlos Honrado
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, VA 22904, USA.
| | | | | | | |
Collapse
|
13
|
Zhu Z, Geng Y, Wang Y. Monitoring Single S. cerevisiae Cells with Multifrequency Electrical Impedance Spectroscopy in an Electrode-Integrated Microfluidic Device. Methods Mol Biol 2021; 2189:105-118. [PMID: 33180297 DOI: 10.1007/978-1-0716-0822-7_9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
This chapter describes an electrode-integrated microfluidic system with multiple functions of manipulating and monitoring single S. cerevisiae cells. In this system, hydrodynamic trapping and negative dielectrophoretic (nDEP) releasing of S. cerevisiae cells are implemented, providing a flexible method for single-cell manipulation. The multiplexing microelectrodes also enable sensitive electrical impedance spectroscopy (EIS) to discern the number of immobilized cells, classify different orientations of captured cells, as well as detect potential movements of immobilized single yeast cells during the overall recording duration by using principal component analysis (PCA) in data mining. The multifrequency EIS measurements can, therefore, obtain sufficient information of S. cerevisiae cells at single-cell level.
Collapse
Affiliation(s)
- Zhen Zhu
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Nanjing, China.
| | - Yangye Geng
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Nanjing, China
| | - Yingying Wang
- Key Laboratory of MEMS of Ministry of Education, Southeast University, Nanjing, China
| |
Collapse
|
14
|
Shi L, Esfandiari L. An Electrokinetically-Driven Microchip for Rapid Entrapment and Detection of Nanovesicles. MICROMACHINES 2020; 12:mi12010011. [PMID: 33374467 PMCID: PMC7823576 DOI: 10.3390/mi12010011] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/18/2020] [Accepted: 12/20/2020] [Indexed: 12/20/2022]
Abstract
Electrical Impedance Spectroscopy (EIS) has been widely used as a label-free and rapid characterization method for the analysis of cells in clinical research. However, the related work on exosomes (40–150 nm) and the particles of similar size has not yet been reported. In this study, we developed a new Lab-on-a-Chip (LOC) device to rapidly entrap a cluster of sub-micron particles, including polystyrene beads, liposomes, and small extracellular vesicles (exosomes), utilizing an insulator-based dielectrophoresis (iDEP) scheme followed by measuring their impedance utilizing an integrated electrical impedance sensor. This technique provides a label-free, fast, and non-invasive tool for the detection of bionanoparticles based on their unique dielectric properties. In the future, this device could potentially be applied to the characterization of pathogenic exosomes and viruses of similar size, and thus, be evolved as a powerful tool for early disease diagnosis and prognosis.
Collapse
Affiliation(s)
- Leilei Shi
- Department of Electrical Engineering and Computer Science, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH 45221, USA;
| | - Leyla Esfandiari
- Department of Electrical Engineering and Computer Science, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH 45221, USA;
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, OH 45221, USA
- Correspondence:
| |
Collapse
|
15
|
Quang LD, Bui TT, Hoang BA, Nhu CN, Thuy HTT, Jen CP, Duc TC. Biological Living Cell in-Flow Detection Based on Microfluidic Chip and Compact Signal Processing Circuit. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:1371-1380. [PMID: 33085615 DOI: 10.1109/tbcas.2020.3030017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Detection and counting of biological living cells in continuous fluidic flows play an essential role in many applications for early diagnosis and treatment of diseases. In this regard, this study highlighted the proposal of a biochip system for detecting and enumerating human lung carcinoma cell flow in the microfluidic channel. The principle of detection was based on the change of impedance between sensing electrodes integrated in the fluidic channel, due to the presence of a biological cell in the sensing region. A compact electronic module was built to sense the unbalanced impedance between the sensing microelectrodes. It consisted of an instrumentation amplifier stage to obtain the difference between the acquired signals, and a lock-in amplifier stage to demodulate the signals at the stimulating frequency as well as to reject noise at other frequencies. The performance of the proposed system was validated through experiments of A549 cells detection as they passed over the microfluidic channel. The experimental results indicated the occurrence of large spikes (up to approximately 180 mV) over the background signal according to the passage of a single A549 cell in the continuous flow. The proposed device is simple-to-operate, inexpensive, portable, and exhibits high sensitivity, which are suitable considerations for developing point-of-care applications.
Collapse
|
16
|
Mahesh K, Varma M, Sen P. Double-peak signal features in microfluidic impedance flow cytometry enable sensitive measurement of cell membrane capacitance. LAB ON A CHIP 2020; 20:4296-4309. [PMID: 33094786 DOI: 10.1039/d0lc00744g] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
The probing of individual cells at specific frequency regimes in a microfluidic impedance flow cytometer led to the observation of unusual "double peak" features in the reactive component of the resulting signal. The phenomenon was restricted to the lower frequencies (400-800 kHz) of the β-dispersion regime and its occurrence was facilitated by the co-planar microelectrode geometry in the device. To understand the reasons for this anomalous behaviour, the system was modelled using COMSOL. The simulated model agreed well with experimental observations and provided insight into the origins of this signal profile and the effect of various parameters on its behaviour. One of the most significant observations of this study was the high sensitivity of the features in the "double peak" profile to changes in cell membrane capacitance (CMC), compared to conventional "single peaks" of reactive impedance. This was consequently exploited to accurately distinguish populations of normal and glutaraldehyde treated erythrocytes based on variations in their CMC, indicating a drastic decrease in the CMC of treated cells. Additionally, we demonstrate the applicability of using this double peak effect to identify cell populations within a mixture of PBMCs. This study is an improvement over conventional approaches of measuring CMC via impedance flow cytometry by enabling the measurement of both cell size and cell membrane properties at a single frequency rather than using multiple frequencies. Using a single frequency significantly simplifies the system and reduces the associated costs. Additionally, this technique enables the measurement of CMC at relatively low frequencies.
Collapse
Affiliation(s)
- Karthik Mahesh
- Centre for Nano Science and Engineering (CeNSE), Indian Institute of Science (IISc), Bangalore 560012, India.
| | - Manoj Varma
- Centre for Nano Science and Engineering (CeNSE), Indian Institute of Science (IISc), Bangalore 560012, India. and Robert Bosch Centre for Cyber Physical Systems (RBCCPS), Indian Institute of Science (IISc), Bangalore 560012, India
| | - Prosenjit Sen
- Centre for Nano Science and Engineering (CeNSE), Indian Institute of Science (IISc), Bangalore 560012, India.
| |
Collapse
|
17
|
Bilican I, Bahadir T, Bilgin K, Guler MT. Alternative screening method for analyzing the water samples through an electrical microfluidics chip with classical microbiological assay comparison of P. aeruginosa. Talanta 2020; 219:121293. [PMID: 32887035 DOI: 10.1016/j.talanta.2020.121293] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Revised: 06/09/2020] [Accepted: 06/10/2020] [Indexed: 12/13/2022]
Abstract
Pseudomonas aeruginosa is a pathogenic bacterium in fresh water supplies that creates a risk for public health. Microbiological analysis of drinking water samples is time consuming and requires qualified personnel. Here we offer a screening system for rapid analysis of spring water that has the potential to be turned into a point-of-need system by means of simple mechanism. The test, which takes 1 h to complete, electrically interrogates the particles through a microfluidic chip suspended in the water sample. We tested the platform using water samples with micro beads and water samples spiked with P. aeruginosa at various concentrations. The mono disperse micro beads were used to evaluate the performance of the system. The results were verified by the gold standard membrane filtration method, which yielded a positive test result only for the P. aeruginosa spiked samples. Detection of 0-11 k bacteria in 30 μL samples was successfully completed in 1 h and compared with a conventional microbiological method. The presented method is a good candidate for a rapid, on-site, screening test that can result in a significant reduction in cost and analysis time compared to microbiological analyses routinely used in practice.
Collapse
Affiliation(s)
- Ismail Bilican
- Science and Technology Application and Research Center, Aksaray University, Aksaray, 68100, Turkey; UNAM-National Nanotechnology Research Center, Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Tolga Bahadir
- Department of Environmental Engineering, Faculty of Engineering, Aksaray University, Aksaray, 68100, Turkey
| | - Kemal Bilgin
- Department of Medical Microbiology, Medical School, Ondokuz Mayis University, Samsun, 55139, Turkey
| | - Mustafa Tahsin Guler
- UNAM-National Nanotechnology Research Center, Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey; Department of Physics, Faculty of Art and Science, Kirikkale University, Kirikkale, 71450, Turkey.
| |
Collapse
|
18
|
Daguerre H, Solsona M, Cottet J, Gauthier M, Renaud P, Bolopion A. Positional dependence of particles and cells in microfluidic electrical impedance flow cytometry: origin, challenges and opportunities. LAB ON A CHIP 2020; 20:3665-3689. [PMID: 32914827 DOI: 10.1039/d0lc00616e] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Microfluidic electrical impedance flow cytometry is now a well-known and established method for single-cell analysis. Given the richness of the information provided by impedance measurements, this non-invasive and label-free approach can be used in a wide field of applications ranging from simple cell counting to disease diagnostics. One of its major limitations is the variation of the impedance signal with the position of the cell in the sensing area. Indeed, identical particles traveling along different trajectories do not result in the same data. The positional dependence can be considered as a challenge for the accuracy of microfluidic impedance cytometers. On the other hand, it has recently been regarded by several groups as an opportunity to estimate the position of particles in the microchannel and thus take a further step in the logic of integrating sensors in so-called "Lab-on-a-chip" devices. This review provides a comprehensive overview of the physical grounds of the positional dependence of impedance measurements. Then, both the developed strategies to reduce position influence in impedance-based assays and the recent reported technologies exploiting that dependence for the integration of position detection in microfluidic devices are reviewed.
Collapse
Affiliation(s)
- Hugo Daguerre
- FEMTO-ST Institute, CNRS, Univ. Bourgogne Franche-Comté, AS2M Department, 24 rue Alain Savary, F-25000 Besançon, France.
| | | | | | | | | | | |
Collapse
|
19
|
Duarte PA, Menze L, Abdelrasoul GN, Yosinski S, Kobos Z, Stuermer R, Reed M, Yang J, Li XS, Chen J. Single ascospore detection for the forecasting of Sclerotinia stem rot of canola. LAB ON A CHIP 2020; 20:3644-3652. [PMID: 32901637 DOI: 10.1039/d0lc00426j] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Smart-agriculture technologies comprise a set of management systems designed to sustainably increase the efficiency and productivity of farming. In this paper, we present a lab-on-a-chip device that can be employed as a plant disease forecasting tool for canola crop. Our device can be employed as a platform to forecast potential outbreaks of one of the most devastating diseases of canola and other crops, Sclerotinia stem rot. The system consists of a microfluidic chip capable of detecting single airborne Sclerotinia sclerotiorum ascospores. Target ascospores are injected into the chip and selectively captured by dielectrophoresis, while other spores in the sample are flushed away. Afterward, captured ascospores are released into the flow stream of the channel and are detected employing electrochemical impedance spectroscopy and coplanar microelectrodes. Our device provides a design for a low-cost, miniaturized, and automated platform technology for airborne spore detection and disease prevention.
Collapse
Affiliation(s)
- Pedro A Duarte
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
| | - Lukas Menze
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
| | - Gaser N Abdelrasoul
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
| | - Shari Yosinski
- School of Engineering and Applied Science, Yale University, New Haven, CT 06511, USA.
| | - Zak Kobos
- School of Engineering and Applied Science, Yale University, New Haven, CT 06511, USA.
| | - Riley Stuermer
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
| | - Mark Reed
- School of Engineering and Applied Science, Yale University, New Haven, CT 06511, USA.
| | - Jian Yang
- InnoTech Alberta Inc., Edmonton, AB T6B 3T9, Canada.
| | - Xiujie S Li
- InnoTech Alberta Inc., Edmonton, AB T6B 3T9, Canada.
| | - Jie Chen
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
| |
Collapse
|
20
|
Rapid Assessment of Surface Markers on Cancer Cells Using Immuno-Magnetic Separation and Multi-frequency Impedance Cytometry for Targeted Therapy. Sci Rep 2020; 10:3015. [PMID: 32080205 PMCID: PMC7033175 DOI: 10.1038/s41598-020-57540-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 12/06/2019] [Indexed: 12/29/2022] Open
Abstract
The rapid qualitative assessment of surface markers on cancer cells can allow for point-of-care prediction of patient response to various cancer drugs. Preclinical studies targeting cells with an antibody to "activated" matriptase conjugated to a potent toxin show promise as a selective treatment for a variety of solid tumors. In this paper, we implemented a novel technique for electrical detection of proteins on surfaces of cancer cells using multi-frequency microfluidic impedance cytometry. The biosensor, consists of two gold microelectrodes on a glass substrate embedded in a PDMS microfluidic channel, is used in conjugation with immuno-magnetic separation of cancer cells, and is capable of differentiating between bare magnetic beads, cancer cells and bead-cell aggregates based on their various impedance and frequency responses. We demonstrated proof-of-concept based on detection of "activated" matriptase proteins on the surface of cultured Mantle cells.
Collapse
|
21
|
Xie X, Zhang Z, Ge X, Zhao X, Hao L, Cheng Z, Zhou W, Du Y, Wang L, Tian F, Xu X. Particle Self-Aligning, Focusing, and Electric Impedance Microcytometer Device for Label-Free Single Cell Morphology Discrimination and Yeast Budding Analysis. Anal Chem 2019; 91:13398-13406. [PMID: 31596074 DOI: 10.1021/acs.analchem.9b01509] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Microfluidic electric impedance flow cytometry (IFC) devices have been applied in single cell analysis, such as cell counting, volume discrimination, cell viability, etc. A cell's shape provides specific information about cellular physiological and pathological conditions, especially in microorganisms such as yeast. In this study, the particle orientation focusing was theoretically analyzed and realized by hydrodynamics. The pulse width (passing time for the particles) of the conductance signal was used to discriminate particle shapes. Spherical and rod-shaped particles with similar volumes/lengths were differentiated by the IFC device, using the impedance pulse parameters of the events. Then, typical late-budding, early budding, and unbudded yeast cells were distinguished by the width, amplitude, and ratio of width to amplitude (R) of the impedance pulse. The pulse amplitude and the R combination gate for identifying the late-budding yeast was estimated through the statistic results. Using the gate, the late-budding rates under different conditions were calculated. Late-budding rates obtained using our method showed a high correlation (R2 = 0.83) with the manual cell counting result and represented the budding status of yeast cells under different conditions proficiently. Thus, the late-budding rate calculated using the above method can be used as a qualitative parameter to assess the reproductive performance of yeast and whether a yeast culturing environment is optimal. This IFC device and cell shape discrimination method is very simple and could be applied in the fermentation industry and other microorganisms' discrimination as a rapid analysis technique in the future.
Collapse
Affiliation(s)
- Xinwu Xie
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,National Bio-Protection Engineering Center , No.106 Wandong Road , Hedong District, Tianjin 300161 , China
| | - Zhiwei Zhang
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,School of Electronic Information and Automation , Tianjin University of Science and Technology , No.1038 Dagunan Road , Hexi District, Tianjin 300222 , China
| | - Xiang Ge
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,School of Electronic Information and Automation , Tianjin University of Science and Technology , No.1038 Dagunan Road , Hexi District, Tianjin 300222 , China
| | - Xiaohao Zhao
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,School of Electronic Information and Automation , Tianjin University of Science and Technology , No.1038 Dagunan Road , Hexi District, Tianjin 300222 , China
| | - Limei Hao
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,National Bio-Protection Engineering Center , No.106 Wandong Road , Hedong District, Tianjin 300161 , China
| | - Zhen Cheng
- Beijing CapitalBio Technology Co. Ltd. , No. 88 block, Kechuang Sixth Rd., Beijing Economic and Technological Development Zone , Beijing 101111 , China
| | - Weibin Zhou
- School of Electronic Information and Automation , Tianjin University of Science and Technology , No.1038 Dagunan Road , Hexi District, Tianjin 300222 , China
| | - Yaohua Du
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China.,National Bio-Protection Engineering Center , No.106 Wandong Road , Hedong District, Tianjin 300161 , China
| | - Lei Wang
- CapitalBio Corporation , National Engineering Research Center for Beijing Biochip Technology , 18 Life Science Parkway , Changping District, Beijing 102206 , China
| | - Feng Tian
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China
| | - Xinxi Xu
- Institute of Medical Support Technology , Academy of Military Science , No.106 Wandong Road , Hedong District, Tianjin 300161 , China
| |
Collapse
|
22
|
Kumar M, Yadav S, Kumar A, Sharma NN, Akhtar J, Singh K. MEMS impedance flow cytometry designs for effective manipulation of micro entities in health care applications. Biosens Bioelectron 2019; 142:111526. [DOI: 10.1016/j.bios.2019.111526] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Revised: 07/02/2019] [Accepted: 07/18/2019] [Indexed: 11/26/2022]
|
23
|
Vembadi A, Menachery A, Qasaimeh MA. Cell Cytometry: Review and Perspective on Biotechnological Advances. Front Bioeng Biotechnol 2019; 7:147. [PMID: 31275933 PMCID: PMC6591278 DOI: 10.3389/fbioe.2019.00147] [Citation(s) in RCA: 70] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Accepted: 05/31/2019] [Indexed: 12/20/2022] Open
Abstract
Cell identification and enumeration are essential procedures within clinical and research laboratories. For over 150 years, quantitative investigation of body fluids such as counts of various blood cells has been an important tool for diagnostic analysis. With the current evolution of point-of-care diagnostics and precision medicine, cheap and precise cell counting technologies are in demand. This article reviews the timeline and recent notable advancements in cell counting that have occurred as a result of improvements in sensing including optical and electrical technology, enhancements in image processing capabilities, and contributions of micro and nanotechnologies. Cell enumeration methods have evolved from the use of manual counting using a hemocytometer to automated cell counters capable of providing reliable counts with high precision and throughput. These developments have been enabled by the use of precision engineering, micro and nanotechnology approaches, automation and multivariate data analysis. Commercially available automated cell counters can be broadly classified into three categories based on the principle of detection namely, electrical impedance, optical analysis and image analysis. These technologies have many common scientific uses, such as hematological analysis, urine analysis and bacterial enumeration. In addition to commercially available technologies, future technological trends using lab-on-a-chip devices have been discussed in detail. Lab-on-a-chip platforms utilize the existing three detection technologies with innovative design changes utilizing advanced nano/microfabrication to produce customized devices suited to specific applications.
Collapse
Affiliation(s)
- Abhishek Vembadi
- Division of Engineering, New York University, Abu Dhabi, United Arab Emirates
| | - Anoop Menachery
- Division of Engineering, New York University, Abu Dhabi, United Arab Emirates
| | - Mohammad A. Qasaimeh
- Division of Engineering, New York University, Abu Dhabi, United Arab Emirates
- Department of Mechanical and Aerospace Engineering, New York University Tandon School of Engineering, Brooklyn, NY, United States
| |
Collapse
|
24
|
Liu Y, Yang Q, Cao L, Xu F. Analysis of Leukocyte Behaviors on Microfluidic Chips. Adv Healthc Mater 2019; 8:e1801406. [PMID: 30672149 DOI: 10.1002/adhm.201801406] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Revised: 01/05/2019] [Indexed: 01/17/2023]
Abstract
The orchestration of massive leukocytes in the immune system protects humans from invading pathogens and abnormal cells in the body. So far, researches focusing on leukocyte behaviors are performed based on both in vivo and in vitro models. The in vivo animal models are usually less controllable due to their extreme complexity and nonignorable species issue. Therefore, many researchers turn to in vitro models. With the advances in micro/nanofabrication, the microfluidic chip has emerged as a novel platform for model construction in multiple biomedical research fields. Specifically, the microfluidic chip is used to study leukocyte behaviors, due to its incomparable advantages in high throughput, precise control, and flexible integration. Moreover, the small size of the microstructures on the microfluidic chip can better mimic the native microenvironment of leukocytes, which contributes to a more reliable recapitulation. Herein are reviewed the recent advances in microfluidic chip-based leukocyte behavior analysis to provide an overview of this field. Detailed discussions are specifically focused on host defense against pathogens, immunodiagnosis, and immunotherapy studies on microfluidic chips. Finally, the current technical challenges are discussed, as well as possible innovations in this field to improve the related applications.
Collapse
Affiliation(s)
- Yan Liu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education; School of Life Science and Technology; Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
- Bioinspired Engineering and Biomechanics Center (BEBC); Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
| | - Qingzhen Yang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education; School of Life Science and Technology; Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
- Bioinspired Engineering and Biomechanics Center (BEBC); Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
| | - Lei Cao
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education; School of Life Science and Technology; Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
- Bioinspired Engineering and Biomechanics Center (BEBC); Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education; School of Life Science and Technology; Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
- Bioinspired Engineering and Biomechanics Center (BEBC); Xi'an Jiaotong University; Xi'an Shaanxi 710049 China
| |
Collapse
|
25
|
Yang K, Wu J, Santos S, Liu Y, Zhu L, Lin F. Recent development of portable imaging platforms for cell-based assays. Biosens Bioelectron 2019; 124-125:150-160. [DOI: 10.1016/j.bios.2018.10.024] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/06/2018] [Accepted: 10/13/2018] [Indexed: 12/22/2022]
|
26
|
Bacteria Detection and Differentiation Using Impedance Flow Cytometry. SENSORS 2018; 18:s18103496. [PMID: 30336557 PMCID: PMC6210208 DOI: 10.3390/s18103496] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 10/11/2018] [Accepted: 10/15/2018] [Indexed: 12/01/2022]
Abstract
Monitoring of bacteria concentrations is of great importance in drinking water management. Continuous real-time monitoring enables better microbiological control of the water and helps prevent contaminated water from reaching the households. We have developed a microfluidic sensor with the potential to accurately assess bacteria levels in drinking water in real-time. Multi frequency electrical impedance spectroscopy is used to monitor a liquid sample, while it is continuously passed through the sensor. We investigate three aspects of this sensor: First we show that the sensor is able to differentiate Escherichia coli (Gram-negative) bacteria from solid particles (polystyrene beads) based on an electrical response in the high frequency phase and individually enumerate the two samples. Next, we demonstrate the sensor’s ability to measure the bacteria concentration by comparing the results to those obtained by the traditional CFU counting method. Last, we show the sensor’s potential to distinguish between different bacteria types by detecting different signatures for S. aureus and E. coli mixed in the same sample. Our investigations show that the sensor has the potential to be extremely effective at detecting sudden bacterial contaminations found in drinking water, and eventually also identify them.
Collapse
|
27
|
Gong Y, Fan N, Yang X, Peng B, Jiang H. New advances in microfluidic flow cytometry. Electrophoresis 2018; 40:1212-1229. [PMID: 30242856 DOI: 10.1002/elps.201800298] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 09/07/2018] [Accepted: 09/15/2018] [Indexed: 01/22/2023]
Abstract
In recent years, researchers are paying the increasing attention to the development of portable microfluidic diagnostic devices including microfluidic flow cytometry for the point-of-care testing. Microfluidic flow cytometry, where microfluidics and flow cytometry work together to realize novel functionalities on the microchip, provides a powerful tool for measuring the multiple characteristics of biological samples. The development of a portable, low-cost, and compact flow cytometer can benefit the health care in underserved areas such as Africa or Asia. In this article, we review recent advancements of microfluidics including sample pumping, focusing and sorting, novel detection approaches, and data analysis in the field of flow cytometry. The challenge of microfluidic flow cytometry is also examined briefly.
Collapse
Affiliation(s)
- Yanli Gong
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Na Fan
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Xu Yang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Bei Peng
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| | - Hai Jiang
- School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China
| |
Collapse
|
28
|
Label-free leukocyte sorting and impedance-based profiling for diabetes testing. Biosens Bioelectron 2018; 118:195-203. [PMID: 30077872 DOI: 10.1016/j.bios.2018.07.052] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 07/18/2018] [Accepted: 07/25/2018] [Indexed: 12/11/2022]
Abstract
Circulating leukocytes comprise of approximately 1% of all blood cells and efficient enrichment of these cells from whole blood is critical for understanding cellular heterogeneity and biological significance in health and diseases. In this work, we report a novel microfluidic strategy for rapid (< 1 h) label-free leukocyte sorting and impedance-based profiling to determine cell activation in type 2 diabetes mellitus (T2DM) using whole blood. Leukocytes were first size-fractionated into different subtypes (neutrophils, monocytes, lymphocytes) using an inertial spiral sorter prior to single-cell impedance measurement in a microfluidic device with coplanar electrode design. Significant changes in membrane dielectric properties (size and opacity) were detected between healthy and activated leukocytes (TNF-α/LPS stimulated), during monocyte differentiation and among different monocyte subsets (classical, intermediate, non-classical). As proof-of-concept for diabetes testing, neutrophil/monocyte dielectric properties in T2DM subjects (n = 8) were quantified which were associated with cardiovascular risk factors including lipid levels, C-reactive protein (CRP) and vascular functions (LnRHI) (P < 0.05) were observed. Overall, these results clearly showed that T2DM subjects have pro-inflammatory leukocyte phenotypes and suggest leukocyte impedance signature as a novel surrogate biomarker for inflammation.
Collapse
|
29
|
Modena MM, Chawla K, Misun PM, Hierlemann A. Smart Cell Culture Systems: Integration of Sensors and Actuators into Microphysiological Systems. ACS Chem Biol 2018; 13:1767-1784. [PMID: 29381325 PMCID: PMC5959007 DOI: 10.1021/acschembio.7b01029] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Technological advances in microfabrication techniques in combination with organotypic cell and tissue models have enabled the realization of microphysiological systems capable of recapitulating aspects of human physiology in vitro with great fidelity. Concurrently, a number of analysis techniques has been developed to probe and characterize these model systems. However, many assays are still performed off-line, which severely compromises the possibility of obtaining real-time information from the samples under examination, and which also limits the use of these platforms in high-throughput analysis. In this review, we focus on sensing and actuation schemes that have already been established or offer great potential to provide in situ detection or manipulation of relevant cell or tissue samples in microphysiological platforms. We will first describe methods that can be integrated in a straightforward way and that offer potential multiplexing and/or parallelization of sensing and actuation functions. These methods include electrical impedance spectroscopy, electrochemical biosensors, and the use of surface acoustic waves for manipulation and analysis of cells, tissue, and multicellular organisms. In the second part, we will describe two sensor approaches based on surface-plasmon resonance and mechanical resonators that have recently provided new characterization features for biological samples, although technological limitations for use in high-throughput applications still exist.
Collapse
Affiliation(s)
- Mario M. Modena
- ETH Zürich, Department of Biosystems Science and Engineering,
Bio Engineering Laboratory, Basel, Switzerland
| | - Ketki Chawla
- ETH Zürich, Department of Biosystems Science and Engineering,
Bio Engineering Laboratory, Basel, Switzerland
| | - Patrick M. Misun
- ETH Zürich, Department of Biosystems Science and Engineering,
Bio Engineering Laboratory, Basel, Switzerland
| | - Andreas Hierlemann
- ETH Zürich, Department of Biosystems Science and Engineering,
Bio Engineering Laboratory, Basel, Switzerland
| |
Collapse
|
30
|
Chien JC, Ameri A, Yeh EC, Killilea AN, Anwar M, Niknejad AM. A high-throughput flow cytometry-on-a-CMOS platform for single-cell dielectric spectroscopy at microwave frequencies. LAB ON A CHIP 2018; 18:2065-2076. [PMID: 29872834 DOI: 10.1039/c8lc00299a] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
This work presents a microfluidics-integrated label-free flow cytometry-on-a-CMOS platform for the characterization of the cytoplasm dielectric properties at microwave frequencies. Compared with MHz impedance cytometers, operating at GHz frequencies offers direct intracellular permittivity probing due to electric fields penetrating through the cellular membrane. To overcome the detection challenges at high frequencies, the spectrometer employs on-chip oscillator-based sensors, which embeds simultaneous frequency generation, electrode excitation, and signal detection capabilities. By employing an injection-locking phase-detection technique, the spectrometer offers state-of-the-art sensitivity, achieving a less than 1 aFrms capacitance detection limit (or 5 ppm in frequency-shift) at a 100 kHz noise filtering bandwidth, enabling high throughput (>1k cells per s), with a measured cellular SNR of more than 28 dB. With CMOS/microfluidics co-design, we distribute four sensing channels at 6.5, 11, 17.5, and 30 GHz in an arrayed format whereas the frequencies are selected to center around the water relaxation frequency at 18 GHz. An issue in the integration of CMOS and microfluidics due to size mismatch is also addressed through introducing a cost-efficient epoxy-molding technique. With 3-D hydrodynamic focusing microfluidics, we perform characterization on four different cell lines including two breast cell lines (MCF-10A and MDA-MB-231) and two leukocyte cell lines (K-562 and THP-1). After normalizing the higher frequency signals to the 6.5 GHz ones, the size-independent dielectric opacity shows a differentiable distribution at 17.5 GHz between normal (0.905 ± 0.160, mean ± std.) and highly metastatic (1.033 ± 0.107) breast cells with p ≪ 0.001.
Collapse
Affiliation(s)
- Jun-Chau Chien
- Department of Electrical Engineering and Computer Science, University of California at Berkeley, Berkeley, CA 94720, USA.
| | | | | | | | | | | |
Collapse
|
31
|
Hassan U, Zhu R, Bashir R. Multivariate computational analysis of biosensor's data for improved CD64 quantification for sepsis diagnosis. LAB ON A CHIP 2018; 18:1231-1240. [PMID: 29564463 DOI: 10.1039/c8lc00108a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Sepsis, as a leading cause of death worldwide, relies on systemic inflammatory response syndrome (SIRS) criteria for its diagnosis. SIRS is highly non-specific as it relies on monitoring of patients' vitals for sepsis diagnosis, which are known to change with many confounding factors. Changes in leukocyte counts and CD64 expression levels are known specific biomarkers of pro-inflammatory host response at the onset of sepsis. Recently, we have developed a biosensor chip that can enumerate the leukocyte counts and quantify the neutrophil CD64 expression levels from a drop of blood. We were able to show improved sepsis diagnosis and prognosis in clinical studies by measuring these parameters during different times of the patients' stay in hospital. In this paper, we investigated the rate of cell capture with CD64 expression levels and used this in a multivariate computational model using artificial neural networks (ANNs) and showed improved accuracy of quantifying CD64 expression levels from the biosensor (n = 106 whole blood experiments). We found a high coefficient of determination and low error between biosensor- and flow cytometry-based neutrophil CD64 expression levels using multiple ANN training methods in comparison to those of univariate regression commonly employed. This approach can find many applications in biosensor data analytics by utilizing multiple features of the biosensor's data for output determination.
Collapse
Affiliation(s)
- U Hassan
- Department of Bioengineering, University of Illinois at Urbana-Champaign, 1270 Digital Computer Laboratory, 1304 W. Springfield Ave, Urbana, IL 61801, USA. and Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, 208 N. Wright St., Urbana, IL 61801, USA and Stevens Family Biomedical Research Center, Carle Foundation Hospital, Urbana, IL 61801, USA
| | - R Zhu
- Department of Statistics, University of Illinois at Urbana Champaign, Illini Hall, 725S Wright St. 101, 61820, Champaign, IL, USA
| | - R Bashir
- Department of Bioengineering, University of Illinois at Urbana-Champaign, 1270 Digital Computer Laboratory, 1304 W. Springfield Ave, Urbana, IL 61801, USA. and Micro and Nanotechnology Lab, University of Illinois at Urbana-Champaign, 208 N. Wright St., Urbana, IL 61801, USA and Stevens Family Biomedical Research Center, Carle Foundation Hospital, Urbana, IL 61801, USA and Carle Illinois College of Medicine, Urbana, IL 61801, USA
| |
Collapse
|
32
|
Murphy TW, Zhang Q, Naler LB, Ma S, Lu C. Recent advances in the use of microfluidic technologies for single cell analysis. Analyst 2017; 143:60-80. [PMID: 29170786 PMCID: PMC5839671 DOI: 10.1039/c7an01346a] [Citation(s) in RCA: 103] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The inherent heterogeneity in cell populations has become of great interest and importance as analytical techniques have improved over the past decades. With the advent of personalized medicine, understanding the impact of this heterogeneity has become an important challenge for the research community. Many different microfluidic approaches with varying levels of throughput and resolution exist to study single cell activity. In this review, we take a broad view of the recent microfluidic developments in single cell analysis based on microwell, microchamber, and droplet platforms. We cover physical, chemical, and molecular biology approaches for cellular and molecular analysis including newly emerging genome-wide analysis.
Collapse
Affiliation(s)
- Travis W Murphy
- Department of Chemical Engineering, Virginia Tech, Blacksburg, VA 24061, USA.
| | | | | | | | | |
Collapse
|
33
|
Qiu X, Zhang J, Gong S, Wang D, Qiao S, Ge S, Xia N, Yu D, Qian S. A Single-Bead-Based, Fully Integrated Microfluidic System for High-Throughput CD4+T Lymphocyte Enumeration. SLAS Technol 2017; 23:134-143. [PMID: 29028426 DOI: 10.1177/2472630317737016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A single-bead-based, fully integrated microfluidic system has been developed for high-throughput CD4+T lymphocyte enumeration at point-of-care testing. Instead of directly counting CD4+T lymphocytes, CD4+T lymphocyte enumeration is achieved by quantitatively detecting CD4 antigen from the lysed blood sample with a functionalized polycarbonate single bead based on chemiluminescence. To implement the sandwiched chemiluminescence immunoassay with reduced nonspecific binding, a streamlined microfluidic chip with multiple reaction chambers is developed to allow each reaction step to be completed in an independent chamber where reagent is pre-stored. With simple magnetic control, the single bead with an embedded ferrous core can be consecutively transported between each of two adjacent chambers for different reactions. Meanwhile, enhanced mixing can be achieved by moving the single bead back and forth inside one chamber with magnetic actuation. High-throughput detection can be performed when a linear actuation stage is adopted to introduce synchronous magnetic control to multiple single beads in parallel microfluidic chips. A sensitive charge-coupled device (CCD) camera is adopted for high-throughput chemiluminescence detection from multiple single beads. Experimental results show that with the fully integrated microfluidic system, easy-to-operate, accurate, low-cost, immediate, and high-throughput CD4+T lymphocyte enumeration can be successfully achieved at resource-poor settings.
Collapse
Affiliation(s)
- Xianbo Qiu
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Junhui Zhang
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Shisong Gong
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China
| | - Dong Wang
- 2 Beijing Wantai Biological Pharmacy Enterprise Co., Beijing, China
| | - Shan Qiao
- 2 Beijing Wantai Biological Pharmacy Enterprise Co., Beijing, China
| | - Shengxiang Ge
- 3 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, China
| | - Ningshao Xia
- 3 National Institute of Diagnostics and Vaccine Development in Infectious Diseases, Xiamen University, Xiamen, China
| | - Duli Yu
- 1 Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology, Beijing University of Chemical Technology, Beijing, China.,4 Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing, China
| | - Shizhi Qian
- 5 Institute of Micro/Nanotechnology, Old Dominion University, Norfolk, VA, USA
| |
Collapse
|
34
|
A point-of-care microfluidic biochip for quantification of CD64 expression from whole blood for sepsis stratification. Nat Commun 2017; 8:15949. [PMID: 28671185 PMCID: PMC5500847 DOI: 10.1038/ncomms15949] [Citation(s) in RCA: 93] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 05/12/2017] [Indexed: 01/20/2023] Open
Abstract
Sepsis, a potentially life-threatening complication of an infection, has the highest burden of death and medical expenses in hospitals worldwide. Leukocyte count and CD64 expression on neutrophils (nCD64) are known to correlate strongly with improved sensitivity and specificity of sepsis diagnosis at its onset. A major challenge is the lack of a rapid and accurate point-of-care (PoC) device that can perform these measurements from a minute blood sample. Here, we report a PoC microfluidic biochip to enumerate leukocytes and quantify nCD64 levels from 10 μl of whole blood without any manual processing. Biochip measurements have shown excellent correlation with the results from flow cytometer. In clinical studies, we have used PoC biochip to monitor leukocyte counts and nCD64 levels from patients’ blood at different times of their stay in the hospital. Furthermore, we have shown the biochip’s utility for improved sepsis diagnosis by combining these measurements with electronic medical record (EMR). Sepsis is a potentially life–threatening complication of infection and diagnosis depends on rapid assessment of leukocyte count and CD64 expression. Here the authors present a microfluidic chip that can quantify these parameters from minimal amounts of whole blood with no manual processing.
Collapse
|
35
|
|
36
|
In situ single cell detection via microfluidic magnetic bead assay. PLoS One 2017; 12:e0172697. [PMID: 28222140 PMCID: PMC5319813 DOI: 10.1371/journal.pone.0172697] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Accepted: 02/08/2017] [Indexed: 01/13/2023] Open
Abstract
We present a single cell detection device based on magnetic bead assay and micro Coulter counters. This device consists of two successive micro Coulter counters, coupled with a high gradient magnetic field generated by an external magnet. The device can identify single cells in terms of the transit time difference of the cell through the two micro Coulter counters. Target cells are conjugated with magnetic beads via specific antibody and antigen binding. A target cell traveling through the two Coulter counters interacts with the magnetic field, and have a longer transit time at the 1st counter than that at the 2nd counter. In comparison, a non-target cell has no interaction with the magnetic field, and hence has nearly the same transit times through the two counters. Each cell passing through the two counters generates two consecutive voltage pulses one after the other; the pulse widths and magnitudes indicating the cell’s transit times through the counters and the cell’s size respectively. Thus, by measuring the pulse widths (transit times) of each cell through the two counters, each single target cell can be differentiated from non-target cells even if they have similar sizes. We experimentally proved that the target human umbilical vein endothelial cells (HUVECs) and non-target rat adipose-derived stem cells (rASCs) have significant different transit time distribution, from which we can determine the recognition regions for both cell groups quantitatively. We further demonstrated that within a mixed cell population of rASCs and HUVECs, HUVECs can be detected in situ and the measured HUVECs ratios agree well with the pre-set ratios. With the simple device structure and easy sample preparation, this method is expected to enable single cell detection in a continuous flow and can be applied to facilitate general cell detection applications such as stem cell identification and enumeration.
Collapse
|
37
|
Tang W, Tang D, Ni Z, Xiang N, Yi H. Microfluidic Impedance Cytometer with Inertial Focusing and Liquid Electrodes for High-Throughput Cell Counting and Discrimination. Anal Chem 2017; 89:3154-3161. [PMID: 28264567 DOI: 10.1021/acs.analchem.6b04959] [Citation(s) in RCA: 45] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
In this paper, we present a novel impedance microcytometer integrated with inertial focusing and liquid electrode techniques for high-throughput cell counting and discrimination. The inertial prefocusing unit orders cells into a determinate train to reduce the possibility of cell adhesions and ensure that only one cell passes through detection region at a time, which improves the accuracy of downstream detection. The liquid electrodes are constructed by inserting Ag/AgCl wires into the electrode chambers filled with flowing highly conductive electrolyte solutions, which have a high detection sensitivity while requiring a simple fabrication process. The effects of main sample flow rate, feed flow rate in electrode chambers, and feed solution type on measured impedance signals are experimentally explored. On the basis of the optimized system, we establish a linear relationship between the amplitude of impedance peaks and the volume of size-calibrated particles and achieve a high detection throughput of ∼5000 cells/s. Finally, using the calibrated microcytometer, we further investigate the size distributions of human breast tumor cells (MCF-7 cells) and leukocytes (white blood cells (WBCs)) and set a threshold amplitude to successfully distinguish the MCF-7 cells spiked in WBCs. Our impedance microcytometer may provide a potential tool for label-free cell enumeration and identification.
Collapse
Affiliation(s)
- Wenlai Tang
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing, Jiangsu 211189, China
| | - Dezhi Tang
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing, Jiangsu 211189, China
| | - Zhonghua Ni
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing, Jiangsu 211189, China
| | - Nan Xiang
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing, Jiangsu 211189, China
| | - Hong Yi
- School of Mechanical Engineering, Jiangsu Key Laboratory for Design and Manufacture of Micro-Nano Biomedical Instruments, Southeast University , Nanjing, Jiangsu 211189, China
| |
Collapse
|
38
|
Electrical Impedance Spectroscopy for Detection of Cells in Suspensions Using Microfluidic Device with Integrated Microneedles. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7020170] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
39
|
Multifunctional, inexpensive, and reusable nanoparticle-printed biochip for cell manipulation and diagnosis. Proc Natl Acad Sci U S A 2017; 114:E1306-E1315. [PMID: 28167769 DOI: 10.1073/pnas.1621318114] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Isolation and characterization of rare cells and molecules from a heterogeneous population is of critical importance in diagnosis of common lethal diseases such as malaria, tuberculosis, HIV, and cancer. For the developing world, point-of-care (POC) diagnostics design must account for limited funds, modest public health infrastructure, and low power availability. To address these challenges, here we integrate microfluidics, electronics, and inkjet printing to build an ultra-low-cost, rapid, and miniaturized lab-on-a-chip (LOC) platform. This platform can perform label-free and rapid single-cell capture, efficient cellular manipulation, rare-cell isolation, selective analytical separation of biological species, sorting, concentration, positioning, enumeration, and characterization. The miniaturized format allows for small sample and reagent volumes. By keeping the electronics separate from microfluidic chips, the former can be reused and device lifetime is extended. Perhaps most notably, the device manufacturing is significantly less expensive, time-consuming, and complex than traditional LOC platforms, requiring only an inkjet printer rather than skilled personnel and clean-room facilities. Production only takes 20 min (vs. up to weeks) and $0.01-an unprecedented cost in clinical diagnostics. The platform works based on intrinsic physical characteristics of biomolecules (e.g., size and polarizability). We demonstrate biomedical applications and verify cell viability in our platform, whose multiplexing and integration of numerous steps and external analyses enhance its application in the clinic, including by nonspecialists. Through its massive cost reduction and usability we anticipate that our platform will enable greater access to diagnostic facilities in developed countries as well as POC diagnostics in resource-poor and developing countries.
Collapse
|
40
|
|
41
|
Kaushik A, Jayant RD, Nair M. Advancements in nano-enabled therapeutics for neuroHIV management. Int J Nanomedicine 2016; 11:4317-25. [PMID: 27621624 PMCID: PMC5012604 DOI: 10.2147/ijn.s109943] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
This viewpoint is a global call to promote fundamental and applied research aiming toward designing smart nanocarriers of desired properties, novel noninvasive strategies to open the blood–brain barrier (BBB), delivery/release of single/multiple therapeutic agents across the BBB to eradicate neurohuman immunodeficiency virus (HIV), strategies for on-demand site-specific release of antiretroviral therapy, developing novel nanoformulations capable to recognize and eradicate latently infected HIV reservoirs, and developing novel smart analytical diagnostic tools to detect and monitor HIV infection. Thus, investigation of novel nanoformulations, methodologies for site-specific delivery/release, analytical methods, and diagnostic tools would be of high significance to eradicate and monitor neuroacquired immunodeficiency syndrome. Overall, these developments will certainly help to develop personalized nanomedicines to cure HIV and to develop smart HIV-monitoring analytical systems for disease management.
Collapse
Affiliation(s)
- Ajeet Kaushik
- Center for Personalized NanoMedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL, USA
| | - Rahul Dev Jayant
- Center for Personalized NanoMedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL, USA
| | - Madhavan Nair
- Center for Personalized NanoMedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL, USA
| |
Collapse
|
42
|
Nair M, Jayant RD, Kaushik A, Sagar V. Getting into the brain: Potential of nanotechnology in the management of NeuroAIDS. Adv Drug Deliv Rev 2016; 103:202-217. [PMID: 26944096 PMCID: PMC4935582 DOI: 10.1016/j.addr.2016.02.008] [Citation(s) in RCA: 114] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 02/17/2016] [Accepted: 02/18/2016] [Indexed: 12/18/2022]
Abstract
In spite of significant advances in antiretroviral (ARV) therapy, the elimination of human immunodeficiency virus (HIV) reservoirs from the periphery and the central nervous system (CNS) remains a formidable task. The incapability of ARV to go across the blood-brain barrier (BBB) after systemic administration makes the brain one of the dominant HIV reservoirs. Thus, screening, monitoring, and elimination of HIV reservoirs from the brain remain a clinically daunting and key task. The practice and investigation of nanomedicine possesses potentials for therapeutics against neuroAIDS. This review highlights the advancements in nanoscience and nanotechnology to design and develop specific size therapeutic cargo for efficient navigation across BBB so as to recognize and eradicate HIV brain reservoirs. Different navigation and drug release strategies, their biocompatibility and efficacy with related challenges and future prospects are also discussed. This review would be an excellent platform to understand nano-enable multidisciplinary research to formulate efficient nanomedicine for the management of neuroAIDS.
Collapse
Key Words
- Anti-retroviral (ARV) therapy
- Blood–brain barrier (BBB)
- Bradykinin (PubChem CID: 439,201)
- CNS drug delivery
- Enfuvirtide (PubChem CID: 16,130,199), Lamivudine & Zidovudine (PubChem CID: 160,352)
- Ferrous oxide or iron (II) oxide (PubChem CID: 14,945)
- Foscarnet sodium (PubChem CID: 44,561)
- HIV monitoring
- HIV-1
- Magnetic nanoparticle
- Mannitol (PubChem CID: 6251)
- Nanotechnology
- Neopterin (PubChem CID: 4455)
- NeuroAIDS
- Pluronic-P85 (PubChem CID: 24,751)
- Saquinavir mesylate (PubChem CID: 60,934)
- Tenofovir disoproxil fumarate (PubChem CID: 6,398,764)
Collapse
Affiliation(s)
- Madhavan Nair
- Center for Personalized Nanomedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33199, USA.
| | - Rahul Dev Jayant
- Center for Personalized Nanomedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33199, USA.
| | - Ajeet Kaushik
- Center for Personalized Nanomedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33199, USA
| | - Vidya Sagar
- Center for Personalized Nanomedicine, Institute of NeuroImmune Pharmacology, Department of Immunology, Herbert Wertheim College of Medicine, Florida International University, Miami, FL 33199, USA
| |
Collapse
|
43
|
Zhao Y, Liu Q, Sun H, Chen D, Li Z, Fan B, George J, Xue C, Cui Z, Wang J, Chen J. Electrical Property Characterization of Neural Stem Cells in Differentiation. PLoS One 2016; 11:e0158044. [PMID: 27341032 PMCID: PMC4920408 DOI: 10.1371/journal.pone.0158044] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Accepted: 06/09/2016] [Indexed: 01/09/2023] Open
Abstract
Electrical property characterization of stem cells could be utilized as a potential label-free biophysical approach to evaluate the differentiation process. However, there has been a lack of technology or tools that can quantify the intrinsic cellular electrical markers (e.g., specific membrane capacitance (Cspecific membrane) and cytoplasm conductivity (σcytoplasm)) for a large amount of stem cells or differentiated cells. In this paper, a microfluidic platform enabling the high-throughput quantification of Cspecific membrane and σcytoplasm from hundreds of single neural stem cells undergoing differentiation was developed to explore the feasibility to characterize the neural stem cell differentiation process without biochemical staining. Experimental quantification using biochemical markers (e.g., Nestin, Tubulin and GFAP) of neural stem cells confirmed the initiation of the differentiation process featured with gradual loss in cellular stemness and increased cell markers for neurons and glial cells. The recorded electrical properties of neural stem cells undergoing differentiation showed distinctive and unique patterns: 1) in the suspension culture before inducing differentiation, a large distribution and difference in σcytoplasm among individual neural stem cells was noticed, which indicated heterogeneity that may result from the nature of suspension culture of neurospheres; and 2) during the differentiation in adhering monolayer culture, significant changes and a large difference in Cspecific membrane were located indicating different expressions of membrane proteins during the differentiation process, and a small distribution difference in σcytoplasm was less significant that indicated the relatively consistent properties of cytoplasm during the culture. In summary, significant differences in Cspecific membrane and σcytoplasm were observed during the neural stem cell differentiation process, which may potentially be used as label-free biophysical markers to monitor this process.
Collapse
Affiliation(s)
- Yang Zhao
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
| | - Qingxi Liu
- Tianjin Weikai Bioeng Ltd., Tianjin, P.R. China
- Tianjin University of Science & Technology, Tianjin, P.R. China
| | - He Sun
- Tianjin Weikai Bioeng Ltd., Tianjin, P.R. China
| | - Deyong Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
| | - Zhaohui Li
- Institute of Biomedical Engineering, Department of Engineering Science, Oxford University, Oxford, United Kingdom
| | - Beiyuan Fan
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
| | - Julian George
- Institute of Biomedical Engineering, Department of Engineering Science, Oxford University, Oxford, United Kingdom
| | - Chengcheng Xue
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
| | - Zhanfeng Cui
- Institute of Biomedical Engineering, Department of Engineering Science, Oxford University, Oxford, United Kingdom
| | - Junbo Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
- * E-mail: (JW); (JC)
| | - Jian Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China
- * E-mail: (JW); (JC)
| |
Collapse
|
44
|
Zhao Y, Jiang M, Chen D, Zhao X, Xue C, Hao R, Yue W, Wang J, Chen J. Single-Cell Electrical Phenotyping Enabling the Classification of Mouse Tumor Samples. Sci Rep 2016; 6:19487. [PMID: 26766416 PMCID: PMC4725910 DOI: 10.1038/srep19487] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Accepted: 12/14/2015] [Indexed: 12/16/2022] Open
Abstract
Single-cell electrical phenotyping (e.g., specific membrane capacitance (Cm) and cytoplasm conductivity (σp)) has long been regarded as potential label-free biophysical markers in tumor status evaluation. However, previous studies only reported the differentiation of tumor cell lines without classifying real tumor samples using cellular electrical properties. In this study, two types of mouse tumor models were constructed by injecting two types of tumor cell lines (A549 and H1299), respectively. Then tumor portions were retrieved for immunohistochemistry studies and single-cell electrical phenotyping based on home-developed microfluidic platforms. Immunohistochemistry results of tumor samples confirmed the adenocarcinoma and large-cell carcinoma characteristics for A549 and H1299 based tumor samples, respectively. Meanwhile, cellular Cm and σp were characterized as 2.25 ± 0.50 μF/cm(2) and 0.96 ± 0.20 S/m for A549 based tumor samples (ncell = 1336, Mouse I, II, III) and 1.76 ± 0.54 μF/cm(2) and 1.35 ± 0.28 S/m for H1299 based tumor samples (ncell = 1442, Mouse IV, V, VI). Significant differences in Cm and σp were observed between these two types of tumor samples, validating the feasibility of using Cm and σp for mouse tumor classification.
Collapse
Affiliation(s)
- Yang Zhao
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| | - Mei Jiang
- Department of Cellular and Molecular Biology, Beijing Chest Hospital, Capital Medical University, Beijing, P.R. China, 101149
| | - Deyong Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| | - Xiaoting Zhao
- Department of Cellular and Molecular Biology, Beijing Chest Hospital, Capital Medical University, Beijing, P.R. China, 101149
| | - Chengcheng Xue
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| | - Rui Hao
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| | - Wentao Yue
- Department of Cellular and Molecular Biology, Beijing Chest Hospital, Capital Medical University, Beijing, P.R. China, 101149
| | - Junbo Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| | - Jian Chen
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing, P.R. China, 100190
| |
Collapse
|
45
|
Attayek PJ, Hunsucker SA, Wang Y, Sims CE, Armistead PM, Allbritton NL. Array-Based Platform To Select, Release, and Capture Epstein-Barr Virus-Infected Cells Based on Intercellular Adhesion. Anal Chem 2015; 87:12281-9. [PMID: 26558605 PMCID: PMC6026766 DOI: 10.1021/acs.analchem.5b03579] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Microraft arrays were developed to select and separate cells based on a complex phenotype, weak intercellular adhesion, without knowledge of cell-surface markers or intracellular proteins. Since the cells were also not competent to bind to a culture surface, a method to encapsulate nonadherent cells within a gelatin plug on the concave microraft surface was developed, enabling release and collection of the cells without the need for cell attachment to the microraft surface. After microraft collection, the gelatin was liquified to release the cell(s) for culture or analysis. A semiautomated release and collection device for the microrafts demonstrated 100 ± 0% collection efficiency of the microraft while increasing throughput 5-fold relative to that of manual release and collection. Using the microraft array platform along with the gelatin encapsulation method, single cells that were not surface-attached were isolated with a 100 ± 0% efficiency and a 96 ± 4% postsort single-cell cloning efficiency. As a demonstration, Epstein-Barr virus-infected lymphoblastoid cell lines (EBV-LCL) were isolated based on their intercellular adhesive properties. The identified cell colonies were collected with a 100 ± 0% sorting efficiency and a postsort viability of 87 ± 3%. When gene expression analysis of the EBV latency-associated gene, EBNA-2, was performed, there was no difference in expression between blasting or weakly adhesive cells and nonblasting or nonadhesive cells. Microraft arrays are a versatile method enabling separation of cells based on complicated and as yet poorly understood cell phenotypes.
Collapse
Affiliation(s)
| | - Sally A Hunsucker
- Lineberger Comprehensive Cancer Center, University of North Carolina School of Medicine , Chapel Hill, North Carolina 27599, United States
| | - Yuli Wang
- Department of Chemistry, University of North Carolina , Chapel HillNorth Carolina 27599, United States
| | - Christopher E Sims
- Department of Chemistry, University of North Carolina , Chapel HillNorth Carolina 27599, United States
| | - Paul M Armistead
- Lineberger Comprehensive Cancer Center, University of North Carolina School of Medicine , Chapel Hill, North Carolina 27599, United States
| | - Nancy L Allbritton
- Lineberger Comprehensive Cancer Center, University of North Carolina School of Medicine , Chapel Hill, North Carolina 27599, United States
- Department of Chemistry, University of North Carolina , Chapel HillNorth Carolina 27599, United States
| |
Collapse
|
46
|
Microfluidic impedance flow cytometry enabling high-throughput single-cell electrical property characterization. Int J Mol Sci 2015; 16:9804-30. [PMID: 25938973 PMCID: PMC4463619 DOI: 10.3390/ijms16059804] [Citation(s) in RCA: 90] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2014] [Revised: 04/10/2015] [Accepted: 04/20/2015] [Indexed: 01/09/2023] Open
Abstract
This article reviews recent developments in microfluidic impedance flow cytometry for high-throughput electrical property characterization of single cells. Four major perspectives of microfluidic impedance flow cytometry for single-cell characterization are included in this review: (1) early developments of microfluidic impedance flow cytometry for single-cell electrical property characterization; (2) microfluidic impedance flow cytometry with enhanced sensitivity; (3) microfluidic impedance and optical flow cytometry for single-cell analysis and (4) integrated point of care system based on microfluidic impedance flow cytometry. We examine the advantages and limitations of each technique and discuss future research opportunities from the perspectives of both technical innovation and clinical applications.
Collapse
|
47
|
Guo J, Chen L, Ai Y, Cheng Y, Li CM, Kang Y, Wang Z. Numerical and experimental characterization of solid-state micropore-based cytometer for detection and enumeration of biological cells. Electrophoresis 2015; 36:737-43. [PMID: 25488493 DOI: 10.1002/elps.201400376] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Revised: 11/25/2014] [Accepted: 11/27/2014] [Indexed: 10/24/2022]
Abstract
Portable diagnostic devices have emerged as important tools in various biomedical applications since they can provide an effective solution for low-cost and rapid clinical diagnosis. In this paper, we present a micropore-based resistive cytometer for the detection and enumeration of biological cells. The proposed device was fabricated on a silicon wafer by a standard microelectromechanical system processing technology, which enables a mass production of the proposed chip. The working principle of this cytometer is based upon a bias potential modulated pulse, originating from the biological particle's physical blockage of the micropore. Polystyrene particles of different sizes (7, 10, and 16 μm) were used to test and calibrate the proposed device. A finite element simulation was developed to predict the bias potential modulated pulse (peak amplitude vs. pulse bandwidth), which can provide critical insight into the design of this microfluidic flow cytometer. Furthermore, HeLa cells (a type of tumor cell lines) spiked in a suspension of blood cells, including red blood cells and white blood cells, were used to assess the performance for detecting and counting tumor cells. The proposed microfluidic flow cytometer is able to provide a promising platform to address the current unmet need for point-of-care clinical diagnosis.
Collapse
Affiliation(s)
- Jinhong Guo
- Institute of Fundamental and Frontier Sciences, University of Electronic Science and Technology of China, Chengdu, P. R. China; Pillar of Engineering Product Development, Singapore University of Technology and Design, Singapore
| | | | | | | | | | | | | |
Collapse
|
48
|
Classification of Cells with Membrane Staining and/or Fixation Based on Cellular Specific Membrane Capacitance and Cytoplasm Conductivity. MICROMACHINES 2015. [DOI: 10.3390/mi6020163] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
49
|
Grenvall C, Antfolk C, Bisgaard CZ, Laurell T. Two-dimensional acoustic particle focusing enables sheathless chip Coulter counter with planar electrode configuration. LAB ON A CHIP 2014; 14:4629-37. [PMID: 25300357 DOI: 10.1039/c4lc00982g] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
The field of cytometry has grown in scope and importance ever since the early 20th century with leaps in technology introducing the Coulter counter and the flow cytometer. Cytometry methods have brought about a revolution for the medical and biotechnology industry by providing fast and accurate analysis of cell and particle suspensions. Recent developments in the field aim at improving current cytometers and to provide miniaturized low-cost cytometry systems for point-of-care clinical diagnostics or research. In an attempt to address the need for particle positioning which is important for both impedance and optically based cytometers we present a microfluidic system which precisely positions cells and particles, using acoustic forces and subsequently performs measurements using an integrated and simple planar electrode Coulter-type impedance cytometer without the need for sheath flows. Data is presented to show how the acoustic method improves the accuracy of the impedance cytometer when prefocusing is employed to particles and cells (diluted whole blood). Confocal imaging and simulations support the findings and provide the basis for further improvements. The acoustophoretic prefocusing technique opens a path towards small, low cost cytometers while also providing an easy way to improve current systems.
Collapse
Affiliation(s)
- Carl Grenvall
- Department of Biomedical Engineering, Lund University, Sweden.
| | | | | | | |
Collapse
|
50
|
Morgan H, Spencer D. Microfluidic Impedance Cytometry for Blood Cell Analysis. MICROFLUIDICS FOR MEDICAL APPLICATIONS 2014. [DOI: 10.1039/9781849737593-00213] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Microfluidic Impedance Cytometry (MIC) is a label-free technique for counting and analyzing single cells at high throughput. Over the last decade the technology has matured into a robust and versatile tool with applications in many areas. Multi-frequency impedance measurements provide information on cell dielectric properties, including cell volume, membrane capacitance, and internal (cytoplasmic) electrical properties. This chapter describes the basic principles underlying MIC together with the technology that enables such measurements. Examples of application in healthcare and diagnostics are provided, including the use of MIC for performing a fast and simple full blood count with a very small volume of sample. The limits of sensitivity of the system are discussed along with novel approaches to enable measurement of small particles such as bacteria. MIC has been used to probe the properties of parasite infected cells, to distinguish tumor cells from normal cells, and even in the differentiation state of stem cells. Addressing future technology challenges, particularly in integrated sample processing, should enable MIC to be used as part of a simple diagnostic toolkit providing sample in, answer out solutions.
Collapse
Affiliation(s)
- Hywel Morgan
- Faculty of Physical and Applied Sciences, and Institute for Life Sciences, University of Southampton UK
| | - Daniel Spencer
- Faculty of Physical and Applied Sciences, and Institute for Life Sciences, University of Southampton UK
| |
Collapse
|