1
|
Ding S, Brownlee BJ, Parate K, Pola CC, Chen B, Hostetter JM, Jones D, Jackman J, Iverson BD, Claussen JC. IFN-γ and IL-10 Immunosensor with Vertically Aligned Carbon Nanotube Interdigitated Electrodes toward Pen-Side Cattle Paratuberculosis Monitoring. GLOBAL CHALLENGES (HOBOKEN, NJ) 2024; 8:2400021. [PMID: 39440229 PMCID: PMC11492326 DOI: 10.1002/gch2.202400021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 07/20/2024] [Indexed: 10/25/2024]
Abstract
Highly sensitive vertically aligned carbon nanotube arrays (VANTAs) interdigitated electrode (IDE) arrays are developed for electrochemical biosensing of two cytokines (i.e., interleukin-10 (IL-10) and interferon-gamma (IFN-γ)) that are useful for early detection Johne's disease (Bovine Paratuberculosis) in cattle. The high aspect ratio VANTA-IDEs (50-60 µm in height) are grown through a chemical vapor deposition process from an iron (Fe) catalyst that is lithographically patterned on a silicon wafer with equal finger width and inter-finger spacing of 25 µm. After functionalization with distinct antibodies the VANTA-IDEs are capable of selective detection of both IL-10 and IFN-γ within an actual biological matrix (i.e., diluted bovine implant supernatant) over concentration ranges of 0.1 to 30 pg mL-1 (limit of detection - LOD: 0.0911 pg mL-1) and 50-500 pg mL-1 (LOD: 24.17 pg mL-1), respectively with a response time of <35 min. Results demonstrate important initial steps for rapid, pen-side identification of cattle with stage-I Mycobacterium avium subspecies paratuberculosis infection before physical symptoms of Johne's disease are present. Such a rapid pen-side diagnostic test can be used on cattle at an auction or before they are introduced to a herd to ensure the larger population does not become infected with Johne's disease.
Collapse
Affiliation(s)
- Shaowei Ding
- Mechanical Engineering DepartmentIowa State UniversityAmesIA50011USA
| | | | - Kshama Parate
- Mechanical Engineering DepartmentIowa State UniversityAmesIA50011USA
| | - Cicero C. Pola
- Mechanical Engineering DepartmentIowa State UniversityAmesIA50011USA
| | - Bolin Chen
- Mechanical Engineering DepartmentIowa State UniversityAmesIA50011USA
| | - Jesse M. Hostetter
- Department of PathologyVeterinary Medicine SchoolIowa State UniversityAmesIA20011USA
| | - Douglas Jones
- Department of PathologyVeterinary Medicine SchoolIowa State UniversityAmesIA20011USA
| | - John Jackman
- Department of Industrial and Mechanical EngineeringIowa State UniversityAmesIA50011USA
| | - Brian D. Iverson
- Department of Mechanical EngineeringBrigham Young UniversityProvoUT84602USA
| | | |
Collapse
|
2
|
Pourmostafa A, Bhusal A, Haridas Menon N, Li Z, Basuray S, Miri AK. Integrating conductive electrodes into hydrogel-based microfluidic chips for real-time monitoring of cell response. Front Bioeng Biotechnol 2024; 12:1421592. [PMID: 39257447 PMCID: PMC11384590 DOI: 10.3389/fbioe.2024.1421592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Accepted: 07/31/2024] [Indexed: 09/12/2024] Open
Abstract
The conventional real-time screening in organs-on-chips is limited to optical tracking of pre-tagged cells and biological agents. This work introduces an efficient biofabrication protocol to integrate tunable hydrogel electrodes into 3D bioprinted-on-chips. We established our method of fabricating cell-laden hydrogel-based microfluidic chips through digital light processing-based 3D bioprinting. Our conductive ink includes poly-(3,4-ethylene-dioxythiophene)-polystyrene sulfonate (PEDOT: PSS) microparticles doped in polyethylene glycol diacrylate (PEGDA). We optimized the manufacturing process of PEDOT: PSS microparticles characterized our conductive ink for different 3D bioprinting parameters, geometries, and materials conditions. While the literature is limited to 0.5% w/v for PEDOT: PSS microparticle concentration, we increased their concentration to 5% w/v with superior biological responses. We measured the conductivity in the 3-15 m/m for a range of 0.5%-5% w/v microparticles, and we showed the effectiveness of 3D-printed electrodes for predicting cell responses when encapsulated in gelatin-methacryloyl (GelMA). Interestingly, a higher cellular activity was observed in the case of 5% w/v microparticles compared to 0.5% w/v microparticles. Electrochemical impedance spectroscopy measurements indicated significant differences in cell densities and spheroid sizes embedded in GelMA microtissues.
Collapse
Affiliation(s)
- Ayda Pourmostafa
- Department of Biomedical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Anant Bhusal
- Department of Mechanical Engineering, Rowan University, Glassboro, NJ, United States
| | - Niranjan Haridas Menon
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Zhenglong Li
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Sagnik Basuray
- Department of Chemical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Glassboro, Newark, NJ, United States
| | - Amir K Miri
- Department of Biomedical Engineering, Newark College of Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| |
Collapse
|
3
|
Bhalerao KS, De Silva PIT, Hiniduma K, Grunbaum A, Rozza N, Kremer R, Rusling JF. Microfluidic Immunoarray for Point-of-Care Detection of Cytokines in COVID-19 Patients. ACS OMEGA 2024; 9:29320-29330. [PMID: 39005811 PMCID: PMC11238202 DOI: 10.1021/acsomega.4c00735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 06/03/2024] [Accepted: 06/10/2024] [Indexed: 07/16/2024]
Abstract
The "cytokine storm" often induced in COVID-19 patients contributes to the onset of "acute respiratory distress syndrome" (ARDS) accompanied by lung infection and damage, multiorgan failure, and even death. This large increase in pro-inflammatory cytokines in blood may be related to severity. Rapid, on-demand cytokine analyses can thus be critical to inform treatment plans and improve survival rates. Here, we report a sensitive, low-cost, semiautomated 3D-printed microfluidic immunoarray to detect 2 cytokines and CRP simultaneously in a single 10 μL serum sample in 25 min. Accuracy was validated by analyzing 80 COVID-19 patient serum samples, with results well correlated to a commercial Meso Scale protein immunoassay. Capture antibodies immobilized in detection microwells in a flat well plate-type flow chamber facilitate the immunoassay, with a programmable syringe pump automatically delivering reagents. Chemiluminescence signals were captured in a dark box with a CCD camera integrated for 30 s. This system was optimized to detect inflammation biomarkers IL-6, IFN-γ, and CRP simultaneously in blood serum. Ultralow limits of detection (LODs) of 0.79 fg/mL for IL-6, 4.2 fg/mL for CRP, and 2.7 fg/mL for IFN-γ with dynamic ranges of up to 100 pg/mL were achieved. ROC statistical analyses showed a relatively good diagnostic value related to the samples assigned WHO COVID-19 scores for disease severity, with the best results for IL-6 and CRP. Monitoring these biomarkers for coronavirus severity may allow prediction of disease severity as a basis for critical treatment decisions and better survival rates.
Collapse
Affiliation(s)
- Ketki S Bhalerao
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - P I Thilini De Silva
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Keshani Hiniduma
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Ami Grunbaum
- Department of Medicine, McGill University Health Centre, 1001 Decarie Blvd., Montreal, QC H3A 1A1, Canada
| | - Nicholas Rozza
- Department of Medicine, McGill University Health Centre, 1001 Decarie Blvd., Montreal, QC H3A 1A1, Canada
| | - Richard Kremer
- Department of Medicine, McGill University Health Centre, 1001 Decarie Blvd., Montreal, QC H3A 1A1, Canada
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Institute of Material Science, University of Connecticut, Storrs, Connecticut 06269, United States
- School of Chemistry, National University of Ireland at Galway, Galway H91 TK33, Ireland
| |
Collapse
|
4
|
Chen W, Huang L, Zhou B. Gold nanourchin on multiple-point dielectrode for glucose biosensing by current-potential measurement. Biotechnol Appl Biochem 2024. [PMID: 38867452 DOI: 10.1002/bab.2626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 05/17/2024] [Accepted: 05/27/2024] [Indexed: 06/14/2024]
Abstract
Gestational diabetes (GD) is a condition characterized by elevated blood sugar levels during pregnancy. GD poses various health risks, such as serious birth injuries, the need for cesarean delivery, and the necessity of newborn care. Monitoring glucose levels is essential for ensuring safe delivery and reducing the risks to both the mother and fetus. Various sensors are readily available for monitoring glucose levels, and researchers are continually working to develop highly sensitive glucose sensors. This research aimed to develop a gold nanourchin (AuNU)-hybrid biosensor for quantifying glucose on a multi-point electrode sensor. Glucose oxidase (GOx) was attached to the AuNU and seeded on the sensing surface using an amine linker. The current-potential (1-2 V at 0.1 V sweep) was recorded for the GOx-glucose interaction, with a limit of detection of 560 μM and a regression coefficient (R2) of 0.9743 [y = 0.9106x - 0.9953] on the linear curve. The sensitivity was estimated to be 3.5 mAcm-2M-1. Furthermore, control experiments with galactose, sucrose, and fructose did not yield an increase in current-potential, confirming specific glucose detection. This experiment helps in monitoring glucose levels to manage conditions associated with GD.
Collapse
Affiliation(s)
- Wei Chen
- Department of Obstetrics (Guoxing), Haikou Hospital of The Maternal and Child Health, Haikou, Hainan Province, China
| | - Lili Huang
- Department of Obstetrics (Guoxing), Haikou Hospital of The Maternal and Child Health, Haikou, Hainan Province, China
| | - Bing Zhou
- Department of Obstetrics (Guoxing), Haikou Hospital of The Maternal and Child Health, Haikou, Hainan Province, China
| |
Collapse
|
5
|
Sidwaba U, Januarie KC, Mini S, Mokwebo KV, Iwuoha E, Feleni U. Bode Phase Angle Signaling of a TB Disease Biomarker. Molecules 2023; 28:8100. [PMID: 38138588 PMCID: PMC10745820 DOI: 10.3390/molecules28248100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/02/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023] Open
Abstract
Tuberculosis (TB) is a worldwide burden whose total control and eradication remains a challenge due to factors including false positive/negative diagnoses associated with the poor sensitivity of the current diagnostics in immune-compromised and post-vaccinated individuals. As these factors complicate both diagnosis and treatment, the early diagnosis of TB is of pivotal importance towards reaching the universal vision of a TB-free world. Here, an aptasensor for signaling an interferon gamma (IFN-γ) TB biomarker at low levels is reported. The aptasensor was assembled through gold-thiol interactions between poly(3,4-propylenedioxythiophene), gold nanoparticles, and a thiol-modified DNA aptamer specific to IFN-γ. The aptasensor sensitively detected IFN-γ in spiked pleural fluid samples with a detection limit of 0.09 pg/mL within a linear range from 0.2 pg/mL to 1.2 pg/mL. The good performance of the reported aptasensor indicates that it holds the potential for application in the early diagnosis of, in addition to TB, various diseases associated with IFN-γ release in clinical samples.
Collapse
Affiliation(s)
- Unathi Sidwaba
- SensorLab (University of the Western Cape Sensor Laboratories), 4th Floor Chemical Sciences Building, University of the Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa; (U.S.); (K.C.J.); (S.M.); (K.V.M.)
| | - Kaylin Cleo Januarie
- SensorLab (University of the Western Cape Sensor Laboratories), 4th Floor Chemical Sciences Building, University of the Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa; (U.S.); (K.C.J.); (S.M.); (K.V.M.)
| | - Sixolile Mini
- SensorLab (University of the Western Cape Sensor Laboratories), 4th Floor Chemical Sciences Building, University of the Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa; (U.S.); (K.C.J.); (S.M.); (K.V.M.)
| | - Kefilwe Vanessa Mokwebo
- SensorLab (University of the Western Cape Sensor Laboratories), 4th Floor Chemical Sciences Building, University of the Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa; (U.S.); (K.C.J.); (S.M.); (K.V.M.)
| | - Emmanuel Iwuoha
- SensorLab (University of the Western Cape Sensor Laboratories), 4th Floor Chemical Sciences Building, University of the Western Cape, Robert Sobukwe Road, Bellville, Cape Town 7535, South Africa; (U.S.); (K.C.J.); (S.M.); (K.V.M.)
| | - Usisipho Feleni
- Institute for Nanotechnology and Water Sustainability (iNanoWS), Florida Campus, College of Science, Engineering and Technology (CSET), University of South Africa (UNISA), Johannesburg 1709, South Africa
| |
Collapse
|
6
|
Yang X, Fan S, Ma Y, Chen H, Xu JF, Pi J, Wang W, Chen G. Current progress of functional nanobiosensors for potential tuberculosis diagnosis: The novel way for TB control? Front Bioeng Biotechnol 2022; 10:1036678. [PMID: 36588948 PMCID: PMC9798010 DOI: 10.3389/fbioe.2022.1036678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 12/02/2022] [Indexed: 12/23/2022] Open
Abstract
Tuberculosis (TB), induced by the foxy Mycobacterium tuberculosis (Mtb), is still one of the top killers worldwide among infectious diseases. Although several antibiotics have been developed to significantly relieve the tuberculosis epidemics worldwide, there are still several important scientific challenges for tuberculosis. As one of the most critical issues for tuberculosis control, the accurate and timely diagnosis of tuberculosis is critical for the following therapy of tuberculosis and thus responsible for the effective control of drug-resistant tuberculosis. Current tuberculosis diagnostic methods in clinic are still facing the difficulties that they can't provide the rapid diagnostic results with high sensitivity and accuracy, which therefore requires the development of more effective novel diagnostic strategies. In recent decades, nanomaterials have been proved to show promising potentials for novel nanobiosensor construction based on their outstanding physical, chemical and biological properties. Taking these promising advantages, nanomaterial-based biosensors show the potential to allow the rapid, sensitive and accurate tuberculosis diagnosis. Here, aiming to increase the development of more effective tuberculosis diagnostic strategy, we summarized the current progress of nanobiosensors for potential tuberculosis diagnosis application. We discussed the different kind diagnostic targets for tuberculosis diagnosis based on nanobiosensors, ranging from the detection of bacterial components from M. tuberculosis, such as DNA and proteins, to the host immunological responses, such as specific cytokine production, and to the direct whole cell detection of M. tuberculosis. We believe that this review would enhance our understandings of nanobiosensors for potential tuberculosis diagnosis, and further promote the future research on nanobiosensor-based tuberculosis diagnosis to benefit the more effective control of tuberculosis epidemic.
Collapse
Affiliation(s)
- Xuran Yang
- Department of Clinical Medicine Laboratory, Affiliated Xiaolan Hospital, Southern Medical University, Zhongshan, China
| | - Shuhao Fan
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, China,Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan, China
| | - Yuhe Ma
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, China,Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan, China
| | - Hui Chen
- Department of Clinical Medicine Laboratory, Affiliated Xiaolan Hospital, Southern Medical University, Zhongshan, China
| | - Jun-Fa Xu
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, China,Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan, China
| | - Jiang Pi
- Guangdong Provincial Key Laboratory of Medical Molecular Diagnostics, The First Dongguan Affiliated Hospital, Guangdong Medical University, Dongguan, China,Institute of Laboratory Medicine, School of Medical Technology, Guangdong Medical University, Dongguan, China,*Correspondence: Jiang Pi, ; Wandang Wang, ; Guanghui Chen,
| | - Wandang Wang
- Department of Clinical Medicine Laboratory, Affiliated Xiaolan Hospital, Southern Medical University, Zhongshan, China,*Correspondence: Jiang Pi, ; Wandang Wang, ; Guanghui Chen,
| | - Guanghui Chen
- Department of Clinical Medicine Laboratory, Affiliated Xiaolan Hospital, Southern Medical University, Zhongshan, China,*Correspondence: Jiang Pi, ; Wandang Wang, ; Guanghui Chen,
| |
Collapse
|
7
|
A highly sensitive, easy-and-rapidly-fabricable microfluidic electrochemical cell with an enhanced three-dimensional electric field. Anal Chim Acta 2022; 1232:340488. [DOI: 10.1016/j.aca.2022.340488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 09/21/2022] [Accepted: 10/04/2022] [Indexed: 11/20/2022]
|
8
|
Bukhamsin A, Ait Lahcen A, Filho JDO, Shetty S, Blilou I, Kosel J, Salama KN. Minimally-invasive, real-time, non-destructive, species-independent phytohormone biosensor for precision farming. Biosens Bioelectron 2022; 214:114515. [DOI: 10.1016/j.bios.2022.114515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 06/10/2022] [Accepted: 06/24/2022] [Indexed: 11/24/2022]
|
9
|
Johnson ZT, Jared N, Peterson JK, Li J, Smith EA, Walper SA, Hooe SL, Breger JC, Medintz IL, Gomes C, Claussen JC. Enzymatic Laser-Induced Graphene Biosensor for Electrochemical Sensing of the Herbicide Glyphosate. GLOBAL CHALLENGES (HOBOKEN, NJ) 2022; 6:2200057. [PMID: 36176938 PMCID: PMC9463521 DOI: 10.1002/gch2.202200057] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 06/17/2022] [Indexed: 06/15/2023]
Abstract
Glyphosate is a globally applied herbicide yet it has been relatively undetectable in-field samples outside of gold-standard techniques. Its presumed nontoxicity toward humans has been contested by the International Agency for Research on Cancer, while it has been detected in farmers' urine, surface waters and crop residues. Rapid, on-site detection of glyphosate is hindered by lack of field-deployable and easy-to-use sensors that circumvent sample transportation to limited laboratories that possess the equipment needed for detection. Herein, the flavoenzyme, glycine oxidase, immobilized on platinum-decorated laser-induced graphene (LIG) is used for selective detection of glyphosate as it is a substrate for GlyOx. The LIG platform provides a scaffold for enzyme attachment while maintaining the electronic and surface properties of graphene. The sensor exhibits a linear range of 10-260 µ m, detection limit of 3.03 µ m, and sensitivity of 0.991 nA µ m -1. The sensor shows minimal interference from the commonly used herbicides and insecticides: atrazine, 2,4-dichlorophenoxyacetic acid, dicamba, parathion-methyl, paraoxon-methyl, malathion, chlorpyrifos, thiamethoxam, clothianidin, and imidacloprid. Sensor function is further tested in complex river water and crop residue fluids, which validate this platform as a scalable, direct-write, and selective method of glyphosate detection for herbicide mapping and food analysis.
Collapse
Affiliation(s)
| | - Nathan Jared
- Department of Mechanical EngineeringIowa State UniversityAmesIA50011USA
| | - John K. Peterson
- Department of Mechanical EngineeringIowa State UniversityAmesIA50011USA
| | - Jingzhe Li
- Department of ChemistryIowa State UniversityAmesIA50011USA
- The Ames LaboratoryU.S. Department of EnergyAmesIA50011USA
| | - Emily A. Smith
- Department of ChemistryIowa State UniversityAmesIA50011USA
- The Ames LaboratoryU.S. Department of EnergyAmesIA50011USA
| | - Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900U.S. Naval Research LaboratoryWashington, D.C20375USA
| | - Shelby L. Hooe
- Center for Bio/Molecular Science and Engineering, Code 6900U.S. Naval Research LaboratoryWashington, D.C20375USA
- National Research CouncilWashington, DC20001USA
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900U.S. Naval Research LaboratoryWashington, D.C20375USA
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900U.S. Naval Research LaboratoryWashington, D.C20375USA
| | - Carmen Gomes
- Department of Mechanical EngineeringIowa State UniversityAmesIA50011USA
| | | |
Collapse
|
10
|
Ahirwar R, Bhattacharya A, Kumar S. Unveiling the underpinnings of various non-conventional ELISA variants: a review article. Expert Rev Mol Diagn 2022; 22:761-774. [PMID: 36004453 DOI: 10.1080/14737159.2022.2117615] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Enzyme-linked immunosorbent assay (ELISA) is a key bio-analytical technique used for the detection of a large array of antigenic substances of scientific, clinical, food safety, and environmental importance. The assay primarily involves capturing and detecting target analytes using specific antigen-antibody interactions. The wide usage of ELISA shoulders on its high specificity and reproducibility. Notwithstanding, the conventional microwell plate-based format of ELISA has some major drawbacks, such as long assay time (4 - 18 h), large sample volumes requirement (100 - 200 μL), lack of multiplicity, and burdensome procedures that limit its utility in rapid and affordable diagnostics. AREAS COVERED Here, we reviewed microfluidic-ELISA, paper-ELISA, aptamer-ELISA, and those based on novel incubation such as heat-ELISA, pressure-ELISA, microwave-ELISA, and sound-ELISA. Further, the current trends and future prospects of these ELISA protocols in clinical diagnostics are discussed. EXPERT OPINION The reviewed non-conventional ELISA formats are relatively rapid, require low reagent volumes, are multiplexable, and could be performed in a low-cost setup. In our opinion, these non-conventional variants of ELISA are on a par with the conventional format for clinical diagnostics and fundamental biological research and hold added clinical translational potential for quick, inexpensive, and convenient measurements.
Collapse
Affiliation(s)
- Rajesh Ahirwar
- Department of Environmental Biochemistry, ICMR-National Institute for Research in Environmental Health, Bhopal-462030, India
| | - Akanksha Bhattacharya
- Department of Environmental Biochemistry, ICMR-National Institute for Research in Environmental Health, Bhopal-462030, India
| | - Saroj Kumar
- School of Biosciences, Apeejay Stya University, Gurgaon- 122103, India
| |
Collapse
|
11
|
Bioanalytical methods encompassing label-free and labeled tuberculosis aptasensors: A review. Anal Chim Acta 2022; 1234:340326. [DOI: 10.1016/j.aca.2022.340326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 08/12/2022] [Accepted: 08/24/2022] [Indexed: 11/22/2022]
|
12
|
Noh S, Lee H, Kim J, Jang H, An J, Park C, Lee MH, Lee T. Rapid electrochemical dual-target biosensor composed of an Aptamer/MXene hybrid on Au microgap electrodes for cytokines detection. Biosens Bioelectron 2022; 207:114159. [DOI: 10.1016/j.bios.2022.114159] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2021] [Revised: 02/22/2022] [Accepted: 03/01/2022] [Indexed: 12/27/2022]
|
13
|
Mikuła E, Katrlík J, Rodrigues LR. Electrochemical Aptasensors for Parkinson's Disease Biomarkers Detection. Curr Med Chem 2022; 29:5795-5814. [PMID: 35619313 DOI: 10.2174/0929867329666220520123337] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 02/07/2022] [Accepted: 03/10/2022] [Indexed: 11/22/2022]
Abstract
BACKGROUND Biomarkers are characteristic molecules that can be measured as indicators of biological process status or condition, exhibiting special relevance in Parkinson's Disease (PD). This disease is a chronic neurodegenerative disorder very difficult to study given the site of pathology and due to a clinical phenotype that fluctuates over time. Currently there is no definitive diagnostic test, thus clinicians hope that the detection of crucial biomarkers will help to the symptomatic and presymptomatic diagnostics and providing surrogate endpoints to demonstrate the clinical efficacy of new treatments. METHODS Electrochemical aptasensors are excellent analytical tools that are used in the detection of PD biomarkers, as they are portable, easy to use, and perform real-time analysis. RESULTS In this review, we discuss the most important clinical biomarkers for PD, highlighting their physiological role and function in the disease. Herein, we review for the first time innovative aptasensors for the detection of current potential PD biomarkers based on electrochemical techniques and discuss future alternatives, including ideal analytical platforms for point-of-care diagnostics. CONCLUSION These new tools will be critical not only in the discovery of sensitive, specific, and reliable biomarkers of preclinical PD, but also in the development of tests that can assist in the early detection and differential diagnosis of parkinsonian disorders and in monitoring disease progression. Various methods for fixing aptamers onto the sensor surfaces, enabling quantitative and specific PD biomarker detection present in synthetic and clinical samples, will also be discussed.
Collapse
Affiliation(s)
- Edyta Mikuła
- Department of Biosensors, Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland
| | - Jaroslav Katrlík
- Institute of Chemistry, Slovak Academy of Sciences, Dúbravská cesta 9, 84538 Bratislava, Slovakia
| | - Ligia R Rodrigues
- Centre of Biological Engineering, Universidade do Minho, Campus de Gualtar, 4710-057, Braga, Portugal
| |
Collapse
|
14
|
Kumar A, Parihar A, Panda U, Parihar DS. Microfluidics-Based Point-of-Care Testing (POCT) Devices in Dealing with Waves of COVID-19 Pandemic: The Emerging Solution. ACS APPLIED BIO MATERIALS 2022; 5:2046-2068. [PMID: 35473316 PMCID: PMC9063993 DOI: 10.1021/acsabm.1c01320] [Citation(s) in RCA: 31] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 04/11/2022] [Indexed: 02/08/2023]
Abstract
Recent advances in microfluidics-based point-of-care testing (POCT) technology such as paper, array, and beads have shown promising results for diagnosing various infectious diseases. The fast and timely detection of viral infection has proven to be a critical step for deciding the therapeutic outcome in the current COVID-19 pandemic, which in turn not only enhances the patient survival rate but also reduces the disease-associated comorbidities. In the present scenario, rapid, noninvasive detection of the virus using low cost and high throughput microfluidics-based POCT devices embraces the advantages over existing diagnostic technologies, for which a centralized lab facility, expensive instruments, sample pretreatment, and skilled personnel are required. Microfluidic-based multiplexed POCT devices can be a boon for clinical diagnosis in developing countries that lacks a centralized health care system and resources. The microfluidic devices can be used for disease diagnosis and exploited for the development and testing of drug efficacy for disease treatment in model systems. The havoc created by the second wave of COVID-19 led several countries' governments to the back front. The lack of diagnostic kits, medical devices, and human resources created a huge demand for a technology that can be remotely operated with single touch and data that can be analyzed on a phone. Recent advancements in information technology and the use of smartphones led to a paradigm shift in the development of diagnostic devices, which can be explored to deal with the current pandemic situation. This review sheds light on various approaches for the development of cost-effective microfluidics POCT devices. The successfully used microfluidic devices for COVID-19 detection under clinical settings along with their pros and cons have been discussed here. Further, the integration of microfluidic devices with smartphones and wireless network systems using the Internet-of-things will enable readers for manufacturing advanced POCT devices for remote disease management in low resource settings.
Collapse
Affiliation(s)
- Avinash Kumar
- Department of Mechanical Engineering,
Indian Institute of Information Technology Design & Manufacturing
Kancheepuram, Chennai 600127, India
| | - Arpana Parihar
- Industrial Waste Utilization, Nano and Biomaterials,
CSIR-Advanced Materials and Processes Research Institute
(AMPRI), Hoshangabad Road, Bhopal, Madhya Pradesh 462026,
India
| | - Udwesh Panda
- Department of Mechanical Engineering,
Indian Institute of Information Technology Design & Manufacturing
Kancheepuram, Chennai 600127, India
| | | |
Collapse
|
15
|
Tang T, Liu Y, Jiang Y. Recent Progress on Highly Selective and Sensitive Electrochemical Aptamer-based Sensors. Chem Res Chin Univ 2022; 38:866-878. [PMID: 35530120 PMCID: PMC9069955 DOI: 10.1007/s40242-022-2084-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 04/10/2022] [Indexed: 12/31/2022]
Abstract
Highly selective, sensitive, and stable biosensors are essential for the molecular level understanding of many physiological activities and diseases. Electrochemical aptamer-based (E-AB) sensor is an appealing platform for measurement in biological system, attributing to the combined advantages of high selectivity of the aptamer and high sensitivity of electrochemical analysis. This review summarizes the latest development of E-AB sensors, focuses on the modification strategies used in the fabrication of sensors and the sensing strategies for analytes of different sizes in biological system, and then looks forward to the challenges and prospects of the future development of electrochemical aptamer-based sensors.
Collapse
Affiliation(s)
- Tianwei Tang
- College of Chemistry, Beijing Normal University, Beijing, 100875 P. R. China
| | - Yinghuan Liu
- College of Chemistry, Beijing Normal University, Beijing, 100875 P. R. China
| | - Ying Jiang
- College of Chemistry, Beijing Normal University, Beijing, 100875 P. R. China
- Beijing National Laboratory for Molecular Sciences, Beijing, 100190 P. R. China
| |
Collapse
|
16
|
Zhou Y, Liu J, Dong H, Liu Z, Wang L, Li Q, Ren J, Zhang Y, Xu M. Target-induced silver nanocluster generation for highly sensitive electrochemical aptasensor towards cell-secreted interferon-γ. Biosens Bioelectron 2022; 203:114042. [DOI: 10.1016/j.bios.2022.114042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 01/07/2022] [Accepted: 01/24/2022] [Indexed: 11/25/2022]
|
17
|
Yerrapragada R M, Mampallil D. Interferon-γ detection in point of care diagnostics: Short review. Talanta 2022; 245:123428. [PMID: 35427946 DOI: 10.1016/j.talanta.2022.123428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Revised: 03/15/2022] [Accepted: 03/30/2022] [Indexed: 12/21/2022]
Abstract
Interferon (IFN)-γ is a cytokine secreted by immune cells. The elevated levels of IFN-γ are an early indicator of multiple diseases such as tuberculosis and autoimmune diseases. This short review focuses on different sensing methods based on optical, electrochemical, and mechanical principles. We explain how specific biorecognition molecules such as antibodies and aptamers are employed in the sensing methods. We also compare different surface functionalization methods and their details. Although the review gives an overview of only IFN-γ sensing, the same strategies can be applied to sensing other analytes with appropriate modifications.
Collapse
Affiliation(s)
- Manjoosha Yerrapragada R
- Indian Institute of Science Education and Research Tirupati, Mangalam P O, Tirupati, 517507, India.
| | - Dileep Mampallil
- Indian Institute of Science Education and Research Tirupati, Mangalam P O, Tirupati, 517507, India.
| |
Collapse
|
18
|
Joshi H, Kandari D, Maitra SS, Bhatnagar R. Biosensors for the detection of Mycobacterium tuberculosis: a comprehensive overview. Crit Rev Microbiol 2022; 48:784-812. [PMID: 35196464 DOI: 10.1080/1040841x.2022.2035314] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Tuberculosis (TB) infection is one of the leading causes of death in the world. According to WHO reports 2019, the average rate of decrease in global TB incidences was only 1.6% per year from 2000 to 2018, besides that the global decline in TB deaths was just 11%. Therefore, the dire need for early detection of the pathogen for the successful diagnosis of TB seems justified. Mycobacterium tuberculosis secretory proteins have gained more attention as TB biomarkers, for the early diagnosis and treatment of TB. Here in this review, we elaborate on the recent advancements made in the field of piezoelectric, magnetic, optical, and electrochemical biosensors, in addition to listing their merits and setbacks. Additionally, this review also discusses the construction of biosensors through modern integrated technologies, such as combinations of analytical chemistry, molecular biology, and nanotechnology. Integrated technologies enhance the detection for perceiving highly selective, specific, and sensitive signals to detect M. tuberculosis. Furthermore, this review highlights the recent challenges and scope of improvement in numerous biosensors developed for rapid, specific, selective, and sensitive detection of tuberculosis to reduce the TB burden and successful treatment.
Collapse
Affiliation(s)
- Hemant Joshi
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Divya Kandari
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Subhrangsu Sundar Maitra
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India
| | - Rakesh Bhatnagar
- Laboratory of Molecular biology and Genetic engineering, School of Biotechnology, Jawaharlal Nehru University, New Delhi, India.,Amity University of Rajasthan, Jaipur, India
| |
Collapse
|
19
|
Interdigitated Electrode for Electrical Characterization of Commercial Pseudo-Binary Biodiesel-Diesel Blends. SENSORS 2021; 21:s21217288. [PMID: 34770592 PMCID: PMC8588433 DOI: 10.3390/s21217288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/02/2021] [Accepted: 10/05/2021] [Indexed: 11/16/2022]
Abstract
Non-standard diesel blends can be harmful to the environment and human health. In this context, a simple analytical method to estimate the biodiesel mixture ratio in diesel was developed based on impedance spectroscopy (IS) associated with interdigitated sensors. In this article, four different interdigitated sensors with varied comb spacing (G) were simulated using the COMSOL Multiphysics software. Based on finite element simulations, four interdigitated electrode architectures were manufactured and evaluated. The best geometry was chosen according to theoretical data simulations, and its interdigitated electrodes were manufactured for the compositional evaluation of pseudo-binary biodiesel–diesel mixtures. According to the X-ray powder diffraction technique, the deposition of the conductive layer (Au0) over the surface of the dielectric substrate (SiO2) did not alter its phase composition. In the analysis of AFM and SEM, it was possible to observe irregular edges on the electrodes, possibly related to the manufacturing process of the thin layers and mechanical stability. Another characteristic observed in the AFM images was the height of the step of the gold layer of the sensor. Several cross sections were obtained, and the mean step value was 225.71 ± 0.0032 nm. Although there were differences in the roughness, the whole sensor had nanometric roughness. Based on the finite element method simulation performed, it can be assumed that the geometric parameters more suitable for the manufacturing of the electrode are W = 20 µm, L = 1000 µm, G = 50 µm, and N = 40 digits. The electrical characterization performed by impedance spectroscopy showed that we could differentiate between biodiesel and diesel fuels and their pseudo-binary mixtures in the low-frequency region.
Collapse
|
20
|
Januarie KC, Uhuo OV, Iwuoha E, Feleni U. Recent advances in the detection of interferon-gamma as a TB biomarker. Anal Bioanal Chem 2021; 414:907-921. [PMID: 34665279 PMCID: PMC8523729 DOI: 10.1007/s00216-021-03702-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/26/2021] [Accepted: 09/27/2021] [Indexed: 12/12/2022]
Abstract
Tuberculosis (TB) is one of the main infectious diseases worldwide and accounts for many deaths. It is caused by Mycobacterium tuberculosis usually affecting the lungs of patients. Early diagnosis and treatment are essential to control the TB epidemic. Interferon-gamma (IFN-γ) is a cytokine that plays a part in the body’s immune response when fighting infection. Current conventional antibody-based TB sensing techniques which are commonly used include enzyme-linked immunosorbent assay (ELISA) and interferon-gamma release assays (IGRAs). However, these methods have major drawbacks, such as being time-consuming, low sensitivity, and inability to distinguish between the different stages of the TB disease. Several electrochemical biosensor systems have been reported for the detection of interferon-gamma with high sensitivity and selectivity. Microfluidic techniques coupled with multiplex analysis in regular format and as lab-on-chip platforms have also been reported for the detection of IFN-γ. This article is a review of the techniques for detection of interferon-gamma as a TB disease biomarker. The objective is to provide a concise assessment of the available IFN-γ detection techniques (including conventional assays, biosensors, microfluidics, and multiplex analysis) and their ability to distinguish the different stages of the TB disease.
Collapse
Affiliation(s)
- Kaylin Cleo Januarie
- SensorLab (University of the Western Cape Sensor Laboratories), University of the Western Cape, 4th Floor Chemical Sciences Building, Robert Sobukwe Road, Bellville, 7535, Cape Town, South Africa.
| | - Onyinyechi V Uhuo
- SensorLab (University of the Western Cape Sensor Laboratories), University of the Western Cape, 4th Floor Chemical Sciences Building, Robert Sobukwe Road, Bellville, 7535, Cape Town, South Africa
| | - Emmanuel Iwuoha
- SensorLab (University of the Western Cape Sensor Laboratories), University of the Western Cape, 4th Floor Chemical Sciences Building, Robert Sobukwe Road, Bellville, 7535, Cape Town, South Africa
| | - Usisipho Feleni
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park, Johannesburg, 1710, South Africa.
| |
Collapse
|
21
|
Liu G, Jiang C, Lin X, Yang Y. Point-of-care detection of cytokines in cytokine storm management and beyond: Significance and challenges. VIEW 2021; 2:20210003. [PMID: 34766163 PMCID: PMC8242812 DOI: 10.1002/viw.20210003] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/01/2021] [Accepted: 03/08/2021] [Indexed: 12/16/2022] Open
Abstract
Cytokines are signaling molecules between cells in immune system. Cytokine storm, due to the sudden acute increase in levels of pro-inflammatory circulating cytokines, can result in disease severity and major-organ damage. Thus, there is urgent need to develop rapid, sensitive, and specific methods for monitoring of cytokines in biology and medicine. Undoubtedly, point-of-care testing (POCT) will provide clinical significance in disease early diagnosis, management, and prevention. This review aims to summarize and discuss the latest technologies for detection of cytokines with a focus on POCT. The overview of diseases resulting from imbalanced cytokine levels, such as COVID-19, sepsis and other cytokine release syndromes are presented. The clinical cut-off levels of cytokine as biomarkers for different diseases are summarized. The challenges and perspectives on the development of cytokine POCT devices are also proposed and discussed. Cytokine POCT devices are expected to be the ongoing spotlight of disease management and prevention during COVID-19 pandemic and also the post COVID-19 pandemic era.
Collapse
Affiliation(s)
- Guozhen Liu
- School of Life and Health SciencesThe Chinese University of Hong KongShenzhen518172P.R. China
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydneyNSW 2052Australia
| | - Cheng Jiang
- Nuffield Department of Clinical NeurosciencesJohn Radcliffe HospitalUniversity of OxfordOxfordOX3 9DUUnited Kingdom
| | - Xiaoting Lin
- Graduate School of Biomedical EngineeringUniversity of New South WalesSydneyNSW 2052Australia
| | - Yang Yang
- School of Life and Health SciencesThe Chinese University of Hong KongShenzhen518172P.R. China
| |
Collapse
|
22
|
ESSENCE – A rapid, shear-enhanced, flow-through, capacitive electrochemical platform for rapid detection of biomolecules. Biosens Bioelectron 2021; 182:113163. [DOI: 10.1016/j.bios.2021.113163] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/25/2021] [Accepted: 03/10/2021] [Indexed: 01/24/2023]
|
23
|
Simões B, Guedens WJ, Keene C, Kubiak-Ossowska K, Mulheran P, Kotowska AM, Scurr DJ, Alexander MR, Broisat A, Johnson S, Muyldermans S, Devoogdt N, Adriaensens P, Mendes PM. Direct Immobilization of Engineered Nanobodies on Gold Sensors. ACS APPLIED MATERIALS & INTERFACES 2021; 13:17353-17360. [PMID: 33845569 PMCID: PMC8153533 DOI: 10.1021/acsami.1c02280] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 03/25/2021] [Indexed: 05/25/2023]
Abstract
Single-domain antibodies, known as nanobodies, have great potential as biorecognition elements for sensors because of their small size, affinity, specificity, and robustness. However, facile and efficient methods of nanobody immobilization are sought that retain their maximum functionality. Herein, we describe the direct immobilization of nanobodies on gold sensors by exploiting a modified cysteine strategically positioned at the C-terminal end of the nanobody. The experimental data based on secondary ion mass spectrometry, circular dichroism, and surface plasmon resonance, taken together with a detailed computational work (molecular dynamics simulations), support the formation of stable and well-oriented nanobody monolayers. Furthermore, the nanobody structure and activity is preserved, wherein the nanobody is immobilized at a high density (approximately 1 nanobody per 13 nm2). The strategy for the spontaneous nanobody self-assembly is simple and effective and possesses exceptional potential to be used in numerous sensing platforms, ranging from clinical diagnosis to environmental monitoring.
Collapse
Affiliation(s)
- Bárbara Simões
- School
of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | - Wanda J. Guedens
- Institute
for Materials Research (IMO), Hasselt University, BE-3590 Diepenbeek, Belgium
| | - Charlie Keene
- School
of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| | | | - Paul Mulheran
- Department
of Chemical & Process Engineering, University
of Strathclyde, Glasgow G1 1XQ, United Kingdom
| | - Anna M. Kotowska
- School
of Pharmacy, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - David J. Scurr
- School
of Pharmacy, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Morgan R Alexander
- School
of Pharmacy, University of Nottingham, Nottingham NG7 2RD, United Kingdom
| | - Alexis Broisat
- Laboratory
of Bioclinical Radiopharmaceutics, Université
Grenoble Alpes, Inserm, CHU Grenoble Alpes, LRB, 38000 Grenoble, France
| | - Steven Johnson
- Department
of Electronic Engineering, University of
York, York YO19 5DD, United Kingdom
| | - Serge Muyldermans
- Cellular
and Molecular Immunology laboratory, Vrije
Universiteit Brussel (VUB), BE-1050 Brussels, Belgium
| | - Nick Devoogdt
- In
vivo Cellular and Molecular Imaging laboratory, Vrije Universiteit Brussel (VUB), BE-1090 Brussels, Belgium
| | - Peter Adriaensens
- Institute
for Materials Research (IMO), Hasselt University, BE-3590 Diepenbeek, Belgium
| | - Paula M. Mendes
- School
of Chemical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT, United Kingdom
| |
Collapse
|
24
|
Bhaskar S, Visweswar Kambhampati NS, Ganesh KM, P MS, Srinivasan V, Ramamurthy SS. Metal-Free, Graphene Oxide-Based Tunable Soliton and Plasmon Engineering for Biosensing Applications. ACS APPLIED MATERIALS & INTERFACES 2021; 13:17046-17061. [PMID: 33788532 DOI: 10.1021/acsami.1c01024] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The quest for auxiliary plasmonic materials with lossless properties began in the past decade. In the current study, a unique plasmonic response is demonstrated from a stratified high refractive index (HRI)-graphene oxide (GO) and low refractive index (LRI)-polymethyl methacrylate (PMMA) multistack. Graphene oxide plasmon-coupled emission (GraPE) reveals the existence of strong surface states on the terminating layer of the photonic crystal (PC) framework. The chemical defects in GO thin film are conducive for unraveling plasmon hybridization within and across the multistack. We have achieved a unique assortment of metal-dielectric-metal (MDM) ensuing a zero-normal steering emission on account of solitons as well as directional GraPE. This has been theoretically established and experimentally demonstrated with a metal-free design. The angle-dependent reflectivity plots, electric field energy (EFI) profiles, and finite-difference time-domain (FDTD) analysis from the simulations strongly support plasmonic modes with giant Purcell factors (PFs). The architecture presented prospects for the replacement of metal-dependent MDM and surface plasmon-coupled emission (SPCE) technology with low cost, easy to fabricate, tunable soliton [graphene oxide plasmon-coupled soliton emission (GraSE)], and plasmon [GraPE] engineering for diverse biosensing applications. The superiority of the GraPE platform for achieving 1.95 pg mL-1 limit of detection of human IFN-γ is validated experimentally. A variety of nanoparticles encompassing metals, intermetallics, rare-earth, and low-dimensional carbon-plasmonic hybrids were used to comprehend PF and cavity hot-spot contribution resulting in 900-fold fluorescence emission enhancements on a lossless substrate, thereby opening the door to unique light-matter interactions for next-gen plasmonic and biomedical technologies.
Collapse
Affiliation(s)
- Seemesh Bhaskar
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| | - Naga Sai Visweswar Kambhampati
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| | - K M Ganesh
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| | - Mahesh Sharma P
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| | - Venkatesh Srinivasan
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| | - Sai Sathish Ramamurthy
- STAR Laboratory, Department of Chemistry, Sri Sathya Sai Institute of Higher Learning, Prasanthi Nilayam, Puttaparthi, Anantapur, Andhra Pradesh 515134, India
| |
Collapse
|
25
|
Rodríguez A, Burgos-Flórez F, Posada JD, Cervera E, Zucolotto V, Sanjuán H, Sanjuán M, Villalba PJ. Electrochemical Immunosensor for the Quantification of S100B at Clinically Relevant Levels Using a Cysteamine Modified Surface. SENSORS 2021; 21:s21061929. [PMID: 33801798 PMCID: PMC8001999 DOI: 10.3390/s21061929] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 02/01/2021] [Accepted: 02/10/2021] [Indexed: 01/14/2023]
Abstract
Neuronal damage secondary to traumatic brain injury (TBI) is a rapidly evolving condition, which requires therapeutic decisions based on the timely identification of clinical deterioration. Changes in S100B biomarker levels are associated with TBI severity and patient outcome. The S100B quantification is often difficult since standard immunoassays are time-consuming, costly, and require extensive expertise. A zero-length cross-linking approach on a cysteamine self-assembled monolayer (SAM) was performed to immobilize anti-S100B monoclonal antibodies onto both planar (AuEs) and interdigitated (AuIDEs) gold electrodes via carbonyl-bond. Surface characterization was performed by atomic force microscopy (AFM) and specular-reflectance FTIR for each functionalization step. Biosensor response was studied using the change in charge-transfer resistance (Rct) from electrochemical impedance spectroscopy (EIS) in potassium ferrocyanide, with [S100B] ranging 10–1000 pg/mL. A single-frequency analysis for capacitances was also performed in AuIDEs. Full factorial designs were applied to assess biosensor sensitivity, specificity, and limit-of-detection (LOD). Higher Rct values were found with increased S100B concentration in both platforms. LODs were 18 pg/mL(AuES) and 6 pg/mL(AuIDEs). AuIDEs provide a simpler manufacturing protocol, with reduced fabrication time and possibly costs, simpler electrochemical response analysis, and could be used for single-frequency analysis for monitoring capacitance changes related to S100B levels.
Collapse
Affiliation(s)
- Alexander Rodríguez
- Biotechnology Research Group, Universidad del Norte, Barranquilla 081007, Colombia; (A.R.); (F.B.-F.); (E.C.); (H.S.)
| | - Francisco Burgos-Flórez
- Biotechnology Research Group, Universidad del Norte, Barranquilla 081007, Colombia; (A.R.); (F.B.-F.); (E.C.); (H.S.)
- Rational Use of Energy and Preservation of the Environment Group (UREMA), Universidad del Norte, Barranquilla 081007, Colombia;
| | - José D. Posada
- School of Medicine, Stanford University, Redwood City, CA 94063, USA;
| | - Eliana Cervera
- Biotechnology Research Group, Universidad del Norte, Barranquilla 081007, Colombia; (A.R.); (F.B.-F.); (E.C.); (H.S.)
| | - Valtencir Zucolotto
- Gnano—Nanomedicine and Nanotoxicology Group, São Carlos Institute of Physics, University of São Paulo, São Carlos 13566-590, São Paulo, Brazil;
| | - Homero Sanjuán
- Biotechnology Research Group, Universidad del Norte, Barranquilla 081007, Colombia; (A.R.); (F.B.-F.); (E.C.); (H.S.)
| | - Marco Sanjuán
- Rational Use of Energy and Preservation of the Environment Group (UREMA), Universidad del Norte, Barranquilla 081007, Colombia;
| | - Pedro J. Villalba
- Biotechnology Research Group, Universidad del Norte, Barranquilla 081007, Colombia; (A.R.); (F.B.-F.); (E.C.); (H.S.)
- Correspondence:
| |
Collapse
|
26
|
Malecka K, Mikuła E, Ferapontova EE. Design Strategies for Electrochemical Aptasensors for Cancer Diagnostic Devices. SENSORS 2021; 21:s21030736. [PMID: 33499136 PMCID: PMC7866130 DOI: 10.3390/s21030736] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 01/12/2021] [Accepted: 01/18/2021] [Indexed: 02/07/2023]
Abstract
Improved outcomes for many types of cancer achieved during recent years is due, among other factors, to the earlier detection of tumours and the greater availability of screening tests. With this, non-invasive, fast and accurate diagnostic devices for cancer diagnosis strongly improve the quality of healthcare by delivering screening results in the most cost-effective and safe way. Biosensors for cancer diagnostics exploiting aptamers offer several important advantages over traditional antibodies-based assays, such as the in-vitro aptamer production, their inexpensive and easy chemical synthesis and modification, and excellent thermal stability. On the other hand, electrochemical biosensing approaches allow sensitive, accurate and inexpensive way of sensing, due to the rapid detection with lower costs, smaller equipment size and lower power requirements. This review presents an up-to-date assessment of the recent design strategies and analytical performance of the electrochemical aptamer-based biosensors for cancer diagnosis and their future perspectives in cancer diagnostics.
Collapse
Affiliation(s)
- Kamila Malecka
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Str. 10, 10-748 Olsztyn, Poland; (K.M.); (E.M.)
| | - Edyta Mikuła
- Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima Str. 10, 10-748 Olsztyn, Poland; (K.M.); (E.M.)
| | - Elena E. Ferapontova
- Interdisciplinary Nanoscience Center (iNANO), Faculty of Science and Technology, Aarhus University, Gustav Wieds Vej 14, 8000 Aarhus C, Denmark
- Correspondence: ; Tel.: +45-87156703
| |
Collapse
|
27
|
Mishra S, Kim ES, Sharma PK, Wang ZJ, Yang SH, Kaushik AK, Wang C, Li Y, Kim NY. Tailored Biofunctionalized Biosensor for the Label-Free Sensing of Prostate-Specific Antigen. ACS APPLIED BIO MATERIALS 2020; 3:7821-7830. [DOI: 10.1021/acsabm.0c01002] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Sachin Mishra
- NDAC Centre, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
| | - Eun-Seong Kim
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
| | - Parshant Kumar Sharma
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
| | - Zhi-Ji Wang
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
| | - Sung-Hyun Yang
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
| | - Ajeet Kumar Kaushik
- NanoBioTech Laboratory, Department of Natural Sciences, Division of Sciences, Arts, & Mathematics, Florida Polytechnic University, Lakeland, Florida 33805, United States
| | - Cong Wang
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
- School of Electronics and Information Engineering, Harbin Institute of Technology, Harbin 150001, China
| | - Yang Li
- School of Electronics and Information Engineering, Harbin Institute of Technology, Harbin 150001, China
- School of Information Science and Engineering, University of Jinan, Jinan 250022, China
| | - Nam-Young Kim
- NDAC Centre, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
- Department of Electronic Engineering, Kwangwoon University, Nowon-gu, Seoul 01897, South Korea
- School of Electronics and Information Engineering, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
28
|
Heras MFL, Ramirez Y, Fernández Martín C, L. Espinosa R, Lavín A, Holgado M. A Point-of-Care Based on Label-Free Interferometric Optical Detection Method to Evaluate Interferon Gamma (IFN-γ): A Correlation with the ELISA Technique. SENSORS (BASEL, SWITZERLAND) 2020; 20:E4776. [PMID: 32847025 PMCID: PMC7506597 DOI: 10.3390/s20174776] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 08/10/2020] [Accepted: 08/21/2020] [Indexed: 12/13/2022]
Abstract
Interferon-gamma (IFN-γ) is a cytokine associated with inflammatory diseases, virus, infection, etc. The quantification of interferon-gamma concentration levels is studied to relate the immune system response to the progression of disease. In this work, we used a label-free point-of-care device based on the increase relative optical power (IROP) and a biosensor based on photonic transducers called BICELLs (Biophotonic Sensing Cells) to evaluate interferon-gamma concentrations. The BICELLs' sensing surface size used is 100 μm in diameter. The bioreceptor is attached to the surface by streptavidin-biotin affinity. This label-free IROP-based device can work with a low concentration of reagents and a low sample volume for measurements. Furthermore, this new device was compared with an ELISA technique in the same conditions. A good correlation was achieved between both techniques. This device is easy to use, and it is a cost-effective tool for monitoring an analyte in a disease.
Collapse
Affiliation(s)
- María Fe Laguna Heras
- Center for Biomedical Technology, Optics, Photonics and Biophotonics Lab., Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain; (Y.R.); (R.L.E.); (A.L.); (M.H.)
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal 2, 28006 Madrid, Spain
| | - Yolanda Ramirez
- Center for Biomedical Technology, Optics, Photonics and Biophotonics Lab., Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain; (Y.R.); (R.L.E.); (A.L.); (M.H.)
- BioOptical Detection SL, Centro de Empresas, Campus Montegancedo, 28223 Madrid, Spain;
| | | | - Rocío L. Espinosa
- Center for Biomedical Technology, Optics, Photonics and Biophotonics Lab., Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain; (Y.R.); (R.L.E.); (A.L.); (M.H.)
| | - Alvaro Lavín
- Center for Biomedical Technology, Optics, Photonics and Biophotonics Lab., Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain; (Y.R.); (R.L.E.); (A.L.); (M.H.)
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal 2, 28006 Madrid, Spain
| | - Miguel Holgado
- Center for Biomedical Technology, Optics, Photonics and Biophotonics Lab., Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain; (Y.R.); (R.L.E.); (A.L.); (M.H.)
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutierrez Abascal 2, 28006 Madrid, Spain
| |
Collapse
|
29
|
Soares RRA, Hjort RG, Pola CC, Parate K, Reis EL, Soares NFF, McLamore ES, Claussen JC, Gomes CL. Laser-Induced Graphene Electrochemical Immunosensors for Rapid and Label-Free Monitoring of Salmonella enterica in Chicken Broth. ACS Sens 2020; 5:1900-1911. [PMID: 32348124 DOI: 10.1021/acssensors.9b02345] [Citation(s) in RCA: 104] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Food-borne illnesses are a growing concern for the food industry and consumers, with millions of cases reported every year. Consequently, there is a critical need to develop rapid, sensitive, and inexpensive techniques for pathogen detection in order to mitigate this problem. However, current pathogen detection strategies mainly include time-consuming laboratory methods and highly trained personnel. Electrochemical in-field biosensors offer a rapid, low-cost alternative to laboratory techniques, but the electrodes used in these biosensors require expensive nanomaterials to increase their sensitivity, such as noble metals (e.g., platinum, gold) or carbon nanomaterials (e.g., carbon nanotubes, or graphene). Herein, we report the fabrication of a highly sensitive and label-free laser-induced graphene (LIG) electrode that is subsequently functionalized with antibodies to electrochemically quantify the food-borne pathogen Salmonella enterica serovar Typhimurium. The LIG electrodes were produced by laser induction on the polyimide film in ambient conditions and, hence, circumvent the need for high-temperature, vacuum environment, and metal seed catalysts commonly associated with graphene-based electrodes fabricated via chemical vapor deposition processes. After functionalization with Salmonella antibodies, the LIG biosensors were able to detect live Salmonella in chicken broth across a wide linear range (25 to 105 CFU mL-1) and with a low detection limit (13 ± 7 CFU mL-1; n = 3, mean ± standard deviation). These results were acquired with an average response time of 22 min without the need for sample preconcentration or redox labeling techniques. Moreover, these LIG immunosensors displayed high selectivity as demonstrated by nonsignificant response to other bacteria strains. These results demonstrate how LIG-based electrodes can be used for electrochemical immunosensing in general and, more specifically, could be used as a viable option for rapid and low-cost pathogen detection in food processing facilities before contaminated foods reach the consumer.
Collapse
Affiliation(s)
- Raquel R. A. Soares
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
- Department of Food Technology, Federal University of Viçosa, Viçosa 36570-900, Brazil
| | - Robert G. Hjort
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Cicero C. Pola
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Kshama Parate
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Efraim L. Reis
- Department of Chemistry, Federal University of Vicosa, Viçosa 36570-900, Brazil
| | - Nilda F. F. Soares
- Department of Food Technology, Federal University of Viçosa, Viçosa 36570-900, Brazil
| | - Eric S. McLamore
- Agricultural & Biological Engineering, University of Florida, Gainesville 32611, Florida, United States
| | - Jonathan C. Claussen
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| | - Carmen L. Gomes
- Department of Mechanical Engineering, Iowa State University, Ames 50011, Iowa, United States
| |
Collapse
|
30
|
Campuzano S, Pedrero M, Gamella M, Serafín V, Yáñez-Sedeño P, Pingarrón JM. Beyond Sensitive and Selective Electrochemical Biosensors: Towards Continuous, Real-Time, Antibiofouling and Calibration-Free Devices. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3376. [PMID: 32560028 PMCID: PMC7348748 DOI: 10.3390/s20123376] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2020] [Revised: 06/12/2020] [Accepted: 06/13/2020] [Indexed: 12/11/2022]
Abstract
Nowadays, electrochemical biosensors are reliable analytical tools to determine a broad range of molecular analytes because of their simplicity, affordable cost, and compatibility with multiplexed and point-of-care strategies. There is an increasing demand to improve their sensitivity and selectivity, but also to provide electrochemical biosensors with important attributes such as near real-time and continuous monitoring in complex or denaturing media, or in vivo with minimal intervention to make them even more attractive and suitable for getting into the real world. Modification of biosensors surfaces with antibiofouling reagents, smart coupling with nanomaterials, and the advances experienced by folded-based biosensors have endowed bioelectroanalytical platforms with one or more of such attributes. With this background in mind, this review aims to give an updated and general overview of these technologies as well as to discuss the remarkable achievements arising from the development of electrochemical biosensors free of reagents, washing, or calibration steps, and/or with antifouling properties and the ability to perform continuous, real-time, and even in vivo operation in nearly autonomous way. The challenges to be faced and the next features that these devices may offer to continue impacting in fields closely related with essential aspects of people's safety and health are also commented upon.
Collapse
Affiliation(s)
- Susana Campuzano
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (M.P.); (M.G.); (V.S.); (P.Y.-S.)
| | | | | | | | | | - José Manuel Pingarrón
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain; (M.P.); (M.G.); (V.S.); (P.Y.-S.)
| |
Collapse
|
31
|
Arshavsky-Graham S, Urmann K, Salama R, Massad-Ivanir N, Walter JG, Scheper T, Segal E. Aptamers vs. antibodies as capture probes in optical porous silicon biosensors. Analyst 2020; 145:4991-5003. [PMID: 32519701 DOI: 10.1039/d0an00178c] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Over the past decade aptamers have emerged as a promising class of bioreceptors for biosensing applications with significant advantages over conventional antibodies. However, experimental studies comparing aptasensors and immunosensors, under equivalent conditions, are limited and the results are inconclusive, in terms of benefits and limitations of each bioreceptor type. In the present work, the performance of aptamer and antibody bioreceptors for the detection of a his-tagged protein, used as a model target, is compared. The bioreceptors are immobilized onto a nanostructured porous silicon (PSi) thin film, used as the optical transducer, and the target protein is detected in a real-time and label-free format by reflective interferometric Fourier transform spectroscopy. For the antibodies, random-oriented immobilization onto the PSi nanostructure results in a poor biosensing performance. Contrary, Fc-oriented immobilization of the antibodies shows a similar biosensing performance to that exhibited by the aptamer-based biosensor, in terms of binding rate, dynamic detection range, limit of detection and selectivity. The aptasensor outperforms in terms of its reusability and storability, while the immunosensor could not be regenerated for subsequent experiments.
Collapse
Affiliation(s)
- Sofia Arshavsky-Graham
- Institute of Technical Chemistry, Leibniz University of Hannover, Callinstr. 5, 30167 Hannover, Germany.
| | | | | | | | | | | | | |
Collapse
|
32
|
Chin M, Tada S, Tsai MH, Ito Y, Luo SC. Strategy to Immobilize Peptide Probe Selected through In Vitro Ribosome Display for Electrochemical Aptasensor Application. Anal Chem 2020; 92:11260-11267. [DOI: 10.1021/acs.analchem.0c01891] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Mi Chin
- Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
| | - Seiichi Tada
- Emergent Bioengineering Materials Research Team, RIKEN Center for Emergent Matter Science, Saitama 351-0198, Japan
| | - Min-Han Tsai
- Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
| | - Yoshihiro Ito
- Emergent Bioengineering Materials Research Team, RIKEN Center for Emergent Matter Science, Saitama 351-0198, Japan
- Nano Medical Engineering Laboratory, RIKEN Cluster for Pioneering Research, 2-1 Hirosawa, Wako, Saitama 351-0198, Japan
| | - Shyh-Chyang Luo
- Department of Materials Science and Engineering, National Taiwan University, No. 1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
| |
Collapse
|
33
|
Gao R, Lu D, Guo D, Xin X. Dual-optofluidic waveguide in-line fiber biosensor for real-time label-free detection of interferon-gamma with temperature compensation. OPTICS EXPRESS 2020; 28:10491-10504. [PMID: 32225632 DOI: 10.1364/oe.389766] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 03/05/2020] [Indexed: 06/10/2023]
Abstract
Temperature cross-sensitivity is a long-standing challenge for most of the in-line fiber optofluidic waveguide biosensors. In this paper, we propose a dual-optofluidic waveguide antiresonant reflecting optical waveguide (ARROW) biosensor for the detection of interferon-gamma (IFN-γ) concentration with temperature compensation. Two Fabry-Perot resonators infiltrated with IFN-γ and NaCl were formed in a hollow core fiber, which generate two resonance dips based on the ARROW model. The optical biosensor for the detection of interferon-gamma (IFN-γ) has been a key research interest in recent years because IFN-γ is an important early biomarker for many serious human diseases. Based on the dual-optofluidic waveguide ARROW biosensor, the IFN-γ concentration can be measured through the modulation of the resonance condition of the ARROW, while the temperature fluctuation can be eliminated due to same thermo-optic coefficients of two infiltration liquids. The experimental results show that the response of the ARROW biosensor can be amplified significantly with the signal-enhanced streptavidin, and the limit of detection of 0.5 ng/ml can be achieved for the IFN-γ concentration. More importantly, the influence of the temperature could be compensated through the referenced resonance dip. The proposed fiber biosensor has a great potential for the real-time detection of IFN-γ concentrations in the fields of health monitoring, cancer prevention, biological engineering, etc.
Collapse
|
34
|
Abstract
Aptasensors form a class of biosensors that function on the basis of a biological recognition. An aptasensor is advantageous because it incorporates a unique biologic recognition element, i.e., an aptamer, coupled to a transducer to convert a biological interaction to readable signals that can be easily processed and reported. In such biosensors, the specificity of aptamers is comparable to and sometimes even better than that of antibodies. Using the SELEX technique, aptamers with high specificity and affinity to various targets can be isolated from large pools of different oligonucleotides. Nowadays, new modifications of the SELEX technique and, as a result, easy generation and synthesis of aptamers have led to the wide application of these materials as biological receptors in biosensors. In this regard, aptamers promise a bright future. In the present research a brief account is initially provided of the recent developments in aptasensors for various targets. Then, immobilization methods, design strategies, current limitations and future directions are discussed for aptasensors.
Collapse
Affiliation(s)
- Laleh Hosseinzadeh
- Department of Chemistry, Dehloran Branch, Islamic Azad University, Dehloran, Iran
| | | |
Collapse
|
35
|
Cheng YH, Barpaga D, Soltis JA, Shutthanandan V, Kargupta R, Han KS, McGrail BP, Motkuri RK, Basuray S, Chatterjee S. Metal-Organic Framework-Based Microfluidic Impedance Sensor Platform for Ultrasensitive Detection of Perfluorooctanesulfonate. ACS APPLIED MATERIALS & INTERFACES 2020; 12:10503-10514. [PMID: 32031779 DOI: 10.1021/acsami.9b22445] [Citation(s) in RCA: 58] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The growing global concerns to public health from human exposure to perfluorooctanesulfonate (PFOS) require rapid, sensitive, in situ detection where current, state-of-the-art techniques are yet to adequately meet sensitivity standards of the real world. This work presents, for the first time, a synergistic approach for the targeted affinity-based capture of PFOS using a porous sorbent probe that enhances detection sensitivity by embedding it on a microfluidic platform. This novel sorbent-containing platform functions as an electrochemical sensor to directly measure PFOS concentration through a proportional change in electrical current (increase in impedance). The extremely high surface area and pore volume of mesoporous metal-organic framework (MOF) Cr-MIL-101 is used as the probe for targeted PFOS capture based on the affinity of the chromium center toward both the fluorine tail groups as well as the sulfonate functionalities as demonstrated by spectroscopic (NMR and XPS) and microscopic (TEM) studies. Answering the need for an ultrasensitive PFOS detection technique, we are embedding the MOF capture probes inside a microfluidic channel, sandwiched between interdigitated microelectrodes (IDμE). The nanoporous geometry, along with interdigitated microelectrodes, increases the signal-to-noise ratio tremendously. Further, the ability of the capture probes to interact with the PFOS at the molecular level and effectively transduce that response electrochemically has allowed us achieve a significant increase in sensitivity. The PFOS detection limit of 0.5 ng/L is unprecedented for in situ analytical PFOS sensors and comparable to quantification limits achieved using state-of-the-art ex situ techniques.
Collapse
Affiliation(s)
- Yu H Cheng
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, United States
| | - Dushyant Barpaga
- Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Jennifer A Soltis
- National Security Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - V Shutthanandan
- Environmental and Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Roli Kargupta
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, United States
| | - Kee Sung Han
- Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - B Peter McGrail
- Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Radha Kishan Motkuri
- Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| | - Sagnik Basuray
- Department of Chemical and Materials Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, United States
| | - Sayandev Chatterjee
- Energy and Environment Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States
| |
Collapse
|
36
|
Lai CY, Huang WC, Weng JH, Chen LC, Chou CF, Wei PK. Impedimetric aptasensing using a symmetric Randles circuit model. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.135750] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
37
|
Parate K, Rangnekar SV, Jing D, Mendivelso-Perez DL, Ding S, Secor EB, Smith EA, Hostetter JM, Hersam MC, Claussen JC. Aerosol-Jet-Printed Graphene Immunosensor for Label-Free Cytokine Monitoring in Serum. ACS APPLIED MATERIALS & INTERFACES 2020; 12:8592-8603. [PMID: 32040290 DOI: 10.1021/acsami.9b22183] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Graphene-based inks are becoming increasingly attractive for printing low-cost and flexible electrical circuits due to their high electrical conductivity, biocompatibility, and manufacturing scalability. Conventional graphene printing techniques, such as screen and inkjet printing, are limited by stringent ink viscosity requirements properties and large as-printed line width that impedes the performance of printed biosensors. Here, we report an aerosol-jet-printed (AJP) graphene-based immunosensor capable of monitoring two distinct cytokines: interferon gamma (IFN-γ) and interleukin 10 (IL-10). Interdigitated electrodes (IDEs) with 40 μm finger widths were printed from graphene-nitrocellulose ink on a polyimide substrate. The IDEs were annealed in CO2 to introduce reactive oxygen species on the graphene surface that act as chemical handles to covalently link IFN-γ and IL-10 antibodies to the graphene surfaces. The resultant AJP electrochemical immunosensors are capable of monitoring cytokines in serum with wide sensing range (IFN-γ: 0.1-5 ng/mL; IL-10: 0.1-2 ng/mL), low detection limit (IFN-γ: 25 pg/ml and IL-10: 46 pg/ml) and high selectivity (antibodies exhibited minimal cross-reactivity with each other and IL-6) without the need for sample prelabeling or preconcentration. Moreover, these biosensors are mechanically flexible with minimal change in signal output after 250 bending cycles over a high curvature (Φ = 5 mm). Hence, this technology could be applied to numerous electrochemical applications that require low-cost electroactive circuits that are disposable and/or flexible.
Collapse
Affiliation(s)
- Kshama Parate
- Department of Mechanical Engineering , Iowa State University , Ames , Iowa 50011 , United States
| | - Sonal V Rangnekar
- Department of Materials Science & Engineering , Northwestern University , Evanston , Illinois 60208 , United States
| | - Dapeng Jing
- Materials Analysis and Research Laboratory , Iowa State University , Ames , Iowa 50010 , Unites States
| | | | - Shaowei Ding
- Department of Mechanical Engineering , Iowa State University , Ames , Iowa 50011 , United States
| | - Ethan B Secor
- Department of Materials Science & Engineering , Northwestern University , Evanston , Illinois 60208 , United States
| | - Emily A Smith
- Department of Chemistry , Iowa State University , Ames , Iowa 50011 , United States
| | - Jesse M Hostetter
- College of Veterinary Medicine , Iowa State University , Ames , Iowa 50011 , United States
| | - Mark C Hersam
- Department of Materials Science & Engineering , Northwestern University , Evanston , Illinois 60208 , United States
| | - Jonathan C Claussen
- Department of Mechanical Engineering , Iowa State University , Ames , Iowa 50011 , United States
| |
Collapse
|
38
|
Coverage degrees of colloids on electrochemical electrodes and signal amplification for anti-citrullinated peptide antibody detection. SENSING AND BIO-SENSING RESEARCH 2020. [DOI: 10.1016/j.sbsr.2020.100322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
|
39
|
Sánchez-Tirado E, González-Cortés A, Yáñez-Sedeño P, Pingarrón JM. Electrochemical immunosensor for the determination of the cytokine interferon gamma (IFN-γ) in saliva. Talanta 2020; 211:120761. [PMID: 32070582 DOI: 10.1016/j.talanta.2020.120761] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Revised: 01/15/2020] [Accepted: 01/17/2020] [Indexed: 11/18/2022]
Abstract
A simple, fast and sensitive amperometric immunosensing method for the determination of the clinically relevant cytokine interferon gamma (IFN-γ) in saliva complying the requirements demanded for this kind of sample is reported. The target analyte was sandwiched between a specific capture antibody covalently immobilized on a screen-printed electrode functionalized by the diazonium salt grafting of p-aminobenzoic acid, and a biotinylated detector antibody labeled with a streptavidin-horseradish peroxidase conjugate. The amperometric responses measured at - 0.20 V vs Ag pseudo-reference electrode upon addition of hydrogen peroxide in the presence of hydroquinone as the redox mediator allowed a calibration plot with a linear range between 2.5 and 2000 pg mL-1 and a low limit of detection (1.6 pg mL-1) to be obtained. In addition, a good selectivity against other non-target proteins was achieved. The developed method was validated by analyzing a WHO 1st International Standard for IFN-γ. In addition, the immunosensor was used for the determination of the endogenous IFN-γ in saliva with results in excellent agreement with those obtained by a commercial ELISA kit.
Collapse
Affiliation(s)
- E Sánchez-Tirado
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, 28040, Madrid, Spain
| | - A González-Cortés
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, 28040, Madrid, Spain
| | - P Yáñez-Sedeño
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, 28040, Madrid, Spain.
| | - J M Pingarrón
- Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, 28040, Madrid, Spain
| |
Collapse
|
40
|
Nano-templated films from waste optical discs for self-powered biosensor application and environmental surveillance. APPLIED NANOSCIENCE 2020. [DOI: 10.1007/s13204-019-01104-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
41
|
Yang X, Zhao J, Chen S, Huang Y, Zhaok S. An ultrasensitive microchip electrophoresis chemiluminescence assay platform for detection of trace biomolecules. J Chromatogr A 2019; 1613:460693. [PMID: 31732154 DOI: 10.1016/j.chroma.2019.460693] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 11/05/2019] [Accepted: 11/07/2019] [Indexed: 11/19/2022]
Abstract
An ultrasensitive microchip electrophoresis chemiluminescence (MCE-CL) assay platform based on separation assisted cascade signal amplification was developed for detection of trace biomolecules. In this work, the aptamer was used as a target probe to bind target molecule and triggering cascade signal amplification reaction. The horseradish peroxide labeled DNA (HRP-DNA) was used as signal probe, utilizing nucleic acid hybridization and exonuclease cutting technology realized ultrasensitive detection of biomolecules on the MCE-CL assay platform. Taking gamma interferon (IFN-γ) as a model analyte, the linear range for IFN-γ detection is 8.0 × 10-15-1.0 × 10-8 M, the detection limit is 1.6 fM, which is six orders magnitude lower than that of without signal amplification. The proposed method was successfully applied for the quantification of IFN-γ in human plasma samples. It was demonstrated that the MCE-CL assay platform was quick, sensitive, and highly selective. It may serve as a tool for clinical analysis of IFN-γ to assist in the diagnosis of disease.
Collapse
Affiliation(s)
- Xing Yang
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection, Guangxi Normal University, Guilin 541004, China
| | - Jingjin Zhao
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection, Guangxi Normal University, Guilin 541004, China.
| | - Shengyu Chen
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection, Guangxi Normal University, Guilin 541004, China
| | - Yong Huang
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection, Guangxi Normal University, Guilin 541004, China
| | - Shulin Zhaok
- State Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection, Guangxi Normal University, Guilin 541004, China.
| |
Collapse
|
42
|
Taki M, Rohilla KJ, Barton M, Funneman M, Benzabeh N, Naphade S, Ellerby LM, Gagnon KT, Shamsi MH. Novel probes for label-free detection of neurodegenerative GGGGCC repeats associated with amyotrophic lateral sclerosis. Anal Bioanal Chem 2019; 411:6995-7003. [PMID: 31435686 PMCID: PMC7433021 DOI: 10.1007/s00216-019-02075-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 07/18/2019] [Accepted: 08/06/2019] [Indexed: 01/28/2023]
Abstract
DNA repeat expansion sequences cause a myriad of neurological diseases when they expand beyond a critical threshold. Previous electrochemical approaches focused on the detection of trinucleotide repeats (CAG, CGG, and GAA) and relied on labeling of the probe and/or target strands or enzyme-linked assays. However, detection of expanded GC-rich sequences is challenging because they are prone to forming secondary structures such as cruciforms and quadruplexes. Here, we present label-free detection of hexanucleotide GGGGCC repeat sequences, which cause the leading genetic form of frontotemporal dementia (FTD) and amyotrophic lateral sclerosis (ALS). The approach relies on capturing targets by surface-bound oligonucleotide probes with a different number of complementary repeats, which proportionately translates the length of the target strands into charge transfer resistance (RCT) signal measured by electrochemical impedance spectroscopy. The probe carrying three tandem repeats transduces the number of repeats into RCT with a 3× higher calibration sensitivity and detection limit. Chronocoulometric measurements show a decrease in surface density with increasing repeat length, which is opposite of the impedance trend. This implies that the length of the target itself can contribute to amplification of the impedance signal independent of the surface density. Moreover, the probe can distinguish between a control and patient sequences while remaining insensitive to non-specific Huntington's disease (CAG) repeats in the presence of a complementary target. This label-free strategy might be applied to detect the length of other neurodegenerative repeat sequences using short probes with a few complementary repeats. Graphical abstract Short oligomeric probes with multiple complementary repeats detect long neurodegenerative targets with high sensitivity and transduce into higher impedance signal.
Collapse
Affiliation(s)
- Motahareh Taki
- Department of Chemistry & Biochemistry, Southern Illinois University, 1245 Lincoln Dr, Carbondale, IL, 62901, USA
| | - Kushal J Rohilla
- Biochemistry and Molecular Biology, Southern Illinois University School of Medicine, Carbondale, IL, 62901, USA
| | - Maria Barton
- Biochemistry and Molecular Biology, Southern Illinois University School of Medicine, Carbondale, IL, 62901, USA
| | - Madison Funneman
- Department of Chemistry & Biochemistry, Southern Illinois University, 1245 Lincoln Dr, Carbondale, IL, 62901, USA
| | - Najiyah Benzabeh
- Department of Chemistry & Biochemistry, Southern Illinois University, 1245 Lincoln Dr, Carbondale, IL, 62901, USA
| | - Swati Naphade
- The Buck Institute for Research on Aging, 8001 Redwood Blvd, Novato, CA, 94945, USA
| | - Lisa M Ellerby
- The Buck Institute for Research on Aging, 8001 Redwood Blvd, Novato, CA, 94945, USA
| | - Keith T Gagnon
- Department of Chemistry & Biochemistry, Southern Illinois University, 1245 Lincoln Dr, Carbondale, IL, 62901, USA
- Biochemistry and Molecular Biology, Southern Illinois University School of Medicine, Carbondale, IL, 62901, USA
| | - Mohtashim H Shamsi
- Department of Chemistry & Biochemistry, Southern Illinois University, 1245 Lincoln Dr, Carbondale, IL, 62901, USA.
| |
Collapse
|
43
|
Li D, Batchelor-McAuley C, Chen L, Compton RG. Band Electrodes in Sensing Applications: Response Characteristics and Band Fabrication Methods. ACS Sens 2019; 4:2250-2266. [PMID: 31407573 DOI: 10.1021/acssensors.9b01172] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This Review surveys the fabrication methods reported for both single microband electrodes and microband electrode arrays and their uses in sensing applications. A theoretical section on band electrodes provides background information on the structure of band electrodes, their diffusional profiles, and the types of voltammetric behavior observed. A short section summarizes the currently available commercial microband electrodes. A section describing recent (10 years) sensing applications using band electrode is also presented.
Collapse
Affiliation(s)
- Danlei Li
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Christopher Batchelor-McAuley
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Lifu Chen
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| | - Richard G. Compton
- Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| |
Collapse
|
44
|
An amplified label-free electrochemical aptasensor of γ-interferon based on target-induced DNA strand transform of hairpin-to-linear conformation enabling simultaneous capture of redox probe and target. Biosens Bioelectron 2019; 145:111732. [PMID: 31577968 DOI: 10.1016/j.bios.2019.111732] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/23/2019] [Accepted: 09/25/2019] [Indexed: 12/18/2022]
Abstract
In this work, a novel and signal-amplified label-free electrochemical aptasensor was developed and enabled efficient determination of γ-interferon (IFN-γ), based on target-induced DNA strand transform of hairpin-to-linear conformation combining with simultaneous capture of redox probe and target. Gold nanoparticles (AuNPs) were electrodeposited in the matrix of poly(amidoamine) dendrimer (PAMAM), followed by drop-casting addition on MoS2 nanosheets to prepare AuNPs- PAMAM/MoS2 composites. HS-terminated hairpin-DNA aptamer of IFN-γ was conjugated with AuNPs to prepare aptamer-AuNPs-PAMAM/MoS2 onto glassy carbon electrode (GCE), by using bovine serum albumin as the cross-linker and stabilizer. Methylene blue (MB) as a redox probe was absorbed on IFN-γ aptamer. In the presence of IFN-γ, MB electrochemical signal increased gradually. The preparation processes, mechanisms and optimal experiment conditions of aptamer- AuNPs-PAMAM/MoS2/MB/GCE sensing platform were studied by electron microscope imaging technologies, spectral curves and electrochemical measurements. There is a well plotting linear relationship between the peak current intensities of MB and IFN-γ contents in the range of 0.01-1000 pg mL-1, showing a low detection limit of 2 fg mL-1. Experimental results testified that the aptasensor had highly sensitive and selective responses toward IFN-γ, over potential interferents. In real biological samples, the aptasensor of IFN-γ had superior detection recoveries, indicating its high detection performance and feasibility for practicability.
Collapse
|
45
|
Golichenari B, Nosrati R, Farokhi-Fard A, Faal Maleki M, Gheibi Hayat SM, Ghazvini K, Vaziri F, Behravan J. Electrochemical-based biosensors for detection of Mycobacterium tuberculosis and tuberculosis biomarkers. Crit Rev Biotechnol 2019; 39:1056-1077. [DOI: 10.1080/07388551.2019.1668348] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Behrouz Golichenari
- Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Department of Pharmaceutical Biotechnology, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Rahim Nosrati
- Cellular and Molecular Research Center, Faculty of Medicine, Guilan University of Medical Sciences, Rasht, Iran
| | - Aref Farokhi-Fard
- Medical Biotechnology Department, Biotechnology Research Center, Pasteur Institute of Iran, Tehran, Iran
| | - Mahdi Faal Maleki
- Department of Pharmaceutical Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran
| | | | - Kiarash Ghazvini
- Department of Microbiology and Virology, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Farzam Vaziri
- Microbiology Research Center (MRC), Pasteur Institute of Iran, Tehran, Iran
- Center for Bioengineering and Biotechnology, University of Waterloo, Waterloo, Canada
| | - Javad Behravan
- Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran
- Center for Bioengineering and Biotechnology, University of Waterloo, Waterloo, Canada
- School of Pharmacy, University of Waterloo, Waterloo, Canada
| |
Collapse
|
46
|
A label-free IFN-γ aptasensor based on target-triggered allosteric switching of aptamer beacon and streptavidin-inorganic hybrid composites. Anal Chim Acta 2019; 1087:29-35. [PMID: 31585563 DOI: 10.1016/j.aca.2019.08.034] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/05/2019] [Accepted: 08/15/2019] [Indexed: 12/31/2022]
Abstract
A label-free electrochemical aptasensor was developed for the sensitive detection of interferon-gamma (IFN-γ). To do this, a diblock dual-aptamer allosteric hairpin (DDAH) was designed, followed by conjugation with gold nanoparticles (DDAH&AuNP). The presence of target destroyed the stable hairpin structure, and then the catalytic cleavage of DNAzymes removed the IFN-γ-binding molecules, triggering the allosteric switching from inactive hairpin to active streptavidin aptamer (A-DDAH&AuNP) in homogeneous system. Moreover, streptavidin-inorganic hybrid nanoflowers decorated with graphene composites (SFG) were synthesized and used as substrates to modify glassy carbon electrodes (SFG/GCE). SFG specifically bind to the A-DDAH&AuNP to realize high-efficient readout of signals. Under the optimal conditions and by using differential pulse stripping voltammetry (DPSV), the response peak currents increases linearly with the logarithm of the IFN-γ concentration in the range between 0.1 pg mL-1 and 500 ng/mL. The detection limit is as low as 19 fg mL-1. The aptasensor also has excellent electrochemical performances, which exhibits broad application prospects in biometric analysis.
Collapse
|
47
|
Vogiazi V, de la Cruz A, Mishra S, Shanov V, Heineman WR, Dionysiou DD. A Comprehensive Review: Development of Electrochemical Biosensors for Detection of Cyanotoxins in Freshwater. ACS Sens 2019; 4:1151-1173. [PMID: 31056912 PMCID: PMC6625642 DOI: 10.1021/acssensors.9b00376] [Citation(s) in RCA: 66] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Cyanobacteria harmful algal blooms are increasing in frequency and cyanotoxins have become an environmental and public concern in the U.S. and worldwide. In this Review, the majority of reported studies and developments of electrochemical affinity biosensors for cyanotoxins are critically reviewed and discussed. Essential background information about cyanobacterial toxins and electrochemical biosensors is combined with the rapidly moving development of electrochemical biosensors for these toxins. Current issues and future challenges for the development of useful electrochemical biosensors for cyanotoxin detection that meet the demands for applications in field freshwater samples are discussed. The major aspects of the entire review article in a prescribed sequence include (i) the state-of-the-art knowledge of the toxicity of cyanotoxins, (ii) important harmful algal bloom events, (iii) advisories, guidelines, and regulations, (iv) conventional analytical methods for determination of cyanotoxins, (v) electrochemical transduction, (vi) recognition receptors, (vii) reported electrochemical biosensors for cyanotoxins, (viii) summary of analytical performance, and (ix) recent advances and future trends. Discussion includes electrochemical techniques and devices, biomolecules with high affinity, numerous array designs, various detection approaches, and research strategies in tailoring the properties of the transducer-biomolecule interface. Scientific and engineering aspects are presented in depth. This review aims to serve as a valuable source to scientists and engineers entering the interdisciplinary field of electrochemical biosensors for detection of cyanotoxins in freshwaters.
Collapse
Affiliation(s)
- Vasileia Vogiazi
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Armah de la Cruz
- Office of Research and Development , US Environmental Protection Agency , Cincinnati , Ohio 45220 , United States
| | - Siddharth Mishra
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - Vesselin Shanov
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
- Mechanical and Materials Engineering , University of Cincinnati , Cincinnati 45221 , Ohio United States
| | - William R Heineman
- Department of Chemistry , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| | - Dionysios D Dionysiou
- Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE) , University of Cincinnati , Cincinnati , Ohio 45221 , United States
| |
Collapse
|
48
|
Campuzano S, Pedrero M, Yáñez-Sedeño P, Pingarrón JM. Antifouling (Bio)materials for Electrochemical (Bio)sensing. Int J Mol Sci 2019; 20:E423. [PMID: 30669466 PMCID: PMC6358752 DOI: 10.3390/ijms20020423] [Citation(s) in RCA: 67] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 01/13/2019] [Accepted: 01/16/2019] [Indexed: 12/20/2022] Open
Abstract
(Bio)fouling processes arising from nonspecific adsorption of biological materials (mainly proteins but also cells and oligonucleotides), reaction products of neurotransmitters oxidation, and precipitation/polymerization of phenolic compounds, have detrimental effects on reliable electrochemical (bio)sensing of relevant analytes and markers either directly or after prolonged incubation in rich-proteins samples or at extreme pH values. Therefore, the design of antifouling (bio)sensing interfaces capable to minimize these undesired processes is a substantial outstanding challenge in electrochemical biosensing. For this purpose, efficient antifouling strategies involving the use of carbon materials, metallic nanoparticles, catalytic redox couples, nanoporous electrodes, electrochemical activation, and (bio)materials have been proposed so far. In this article, biomaterial-based strategies involving polymers, hydrogels, peptides, and thiolated self-assembled monolayers are reviewed and critically discussed. The reported strategies have been shown to be successful to overcome (bio)fouling in a diverse range of relevant practical applications. We highlight recent examples for the reliable sensing of particularly fouling analytes and direct/continuous operation in complex biofluids or harsh environments. Opportunities, unmet challenges, and future prospects in this field are also pointed out.
Collapse
Affiliation(s)
- Susana Campuzano
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | - María Pedrero
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | - Paloma Yáñez-Sedeño
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| | - José M Pingarrón
- Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
| |
Collapse
|
49
|
Evans D, Papadimitriou KI, Vasilakis N, Pantelidis P, Kelleher P, Morgan H, Prodromakis T. A Novel Microfluidic Point-of-Care Biosensor System on Printed Circuit Board for Cytokine Detection. SENSORS (BASEL, SWITZERLAND) 2018; 18:E4011. [PMID: 30453609 PMCID: PMC6264023 DOI: 10.3390/s18114011] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/06/2018] [Accepted: 11/12/2018] [Indexed: 01/17/2023]
Abstract
Point of Care (PoC) diagnostics have been the subject of considerable research over the last few decades driven by the pressure to detect diseases quickly and effectively and reduce healthcare costs. Herein, we demonstrate a novel, fully integrated, microfluidic amperometric enzyme-linked immunosorbent assay (ELISA) prototype using a commercial interferon gamma release assay (IGRA) as a model antibody binding system. Microfluidic assay chemistry was engineered to take place on Au-plated electrodes within an assay cell on a printed circuit board (PCB)-based biosensor system. The assay cell is linked to an electrochemical reporter cell comprising microfluidic architecture, Au working and counter electrodes and a Ag/AgCl reference electrode, all manufactured exclusively via standard commercial PCB fabrication processes. Assay chemistry has been optimised for microfluidic diffusion kinetics to function under continual flow. We characterised the electrode integrity of the developed platforms with reference to biological sampling and buffer composition and subsequently we demonstrated concentration-dependent measurements of H₂O₂ depletion as resolved by existing FDA-validated ELISA kits. Finally, we validated the assay technology in both buffer and serum and demonstrate limits of detection comparable to high-end commercial systems with the addition of full microfluidic assay architecture capable of returning diagnostic analyses in approximately eight minutes.
Collapse
Affiliation(s)
- Daniel Evans
- Nanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
| | - Konstantinos I Papadimitriou
- Nanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
| | - Nikolaos Vasilakis
- Nanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
| | - Panagiotis Pantelidis
- Centre for Immunology and Vaccinology, Division of Infectious Diseases, Department of Medicine, Imperial College London, London SW10 9NH, UK.
- Infection and Immunity, North West London Pathology, Imperial College NHS Trust, Charing Cross Hospital, London W6 8RF, UK.
| | - Peter Kelleher
- Centre for Immunology and Vaccinology, Division of Infectious Diseases, Department of Medicine, Imperial College London, London SW10 9NH, UK.
- Infection and Immunity, North West London Pathology, Imperial College NHS Trust, Charing Cross Hospital, London W6 8RF, UK.
| | - Hywel Morgan
- Nanoelectronics & Nanotechnology Research Group, Electronics and Computer Science, University of Southampton, Southampton SO17 1BJ, UK.
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK.
| | - Themistoklis Prodromakis
- Zepler Institute for Photonics and Nanoelectronics, University of Southampton, Southampton SO17 1BJ, UK.
| |
Collapse
|
50
|
Ding S, Das SR, Brownlee BJ, Parate K, Davis TM, Stromberg LR, Chan EK, Katz J, Iverson BD, Claussen JC. CIP2A immunosensor comprised of vertically-aligned carbon nanotube interdigitated electrodes towards point-of-care oral cancer screening. Biosens Bioelectron 2018; 117:68-74. [DOI: 10.1016/j.bios.2018.04.016] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 04/07/2018] [Indexed: 11/28/2022]
|