1
|
Guitart C, Bobillo-Perez S, Rodríguez-Fanjul J, Carrasco JL, Brotons P, López-Ramos MG, Cambra FJ, Balaguer M, Jordan I. Lung ultrasound and procalcitonin, improving antibiotic management and avoiding radiation exposure in pediatric critical patients with bacterial pneumonia: a randomized clinical trial. Eur J Med Res 2024; 29:222. [PMID: 38581075 PMCID: PMC10998368 DOI: 10.1186/s40001-024-01712-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 02/03/2024] [Indexed: 04/07/2024] Open
Abstract
BACKGROUND Pneumonia is a major public health problem with an impact on morbidity and mortality. Its management still represents a challenge. The aim was to determine whether a new diagnostic algorithm combining lung ultrasound (LUS) and procalcitonin (PCT) improved pneumonia management regarding antibiotic use, radiation exposure, and associated costs, in critically ill pediatric patients with suspected bacterial pneumonia (BP). METHODS Randomized, blinded, comparative effectiveness clinical trial. Children < 18y with suspected BP admitted to the PICU from September 2017 to December 2019, were included. PCT was determined at admission. Patients were randomized into the experimental group (EG) and control group (CG) if LUS or chest X-ray (CXR) were done as the first image test, respectively. Patients were classified: 1.LUS/CXR not suggestive of BP and PCT < 1 ng/mL, no antibiotics were recommended; 2.LUS/CXR suggestive of BP, regardless of the PCT value, antibiotics were recommended; 3.LUS/CXR not suggestive of BP and PCT > 1 ng/mL, antibiotics were recommended. RESULTS 194 children were enrolled, 113 (58.2%) females, median age of 134 (IQR 39-554) days. 96 randomized into EG and 98 into CG. 1. In 75/194 patients the image test was not suggestive of BP with PCT < 1 ng/ml; 29/52 in the EG and 11/23 in the CG did not receive antibiotics. 2. In 101 patients, the image was suggestive of BP; 34/34 in the EG and 57/67 in the CG received antibiotics. Statistically significant differences between groups were observed when PCT resulted < 1 ng/ml (p = 0.01). 3. In 18 patients the image test was not suggestive of BP but PCT resulted > 1 ng/ml, all of them received antibiotics. A total of 0.035 mSv radiation/patient was eluded. A reduction of 77% CXR/patient was observed. LUS did not significantly increase costs. CONCLUSIONS Combination of LUS and PCT showed no risk of mistreating BP, avoided radiation and did not increase costs. The algorithm could be a reliable tool for improving pneumonia management. CLINICAL TRIAL REGISTRATION NCT04217980.
Collapse
Affiliation(s)
- Carmina Guitart
- Paediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain
- Immunological and Respiratory Disorders in the Pediatric Critical Patient Research Group, Institut de Recerca Sant Joan de Déu, University of Barcelona, Barcelona, Spain
- Pediatric Infectious Diseases Research Group, Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llogregat, Spain
| | - Sara Bobillo-Perez
- Paediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain
- Immunological and Respiratory Disorders in the Pediatric Critical Patient Research Group, Institut de Recerca Sant Joan de Déu, University of Barcelona, Barcelona, Spain
- Pediatric Infectious Diseases Research Group, Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llogregat, Spain
| | - Javier Rodríguez-Fanjul
- Neonatal Intensive Care Unit, Department of Pediatrics, Hospital Germans Trias i Pujol, Autonomous University of Barcelona, Badalona, Spain
| | - José Luis Carrasco
- Department of Basic Clinical Practice, University of Barcelona, Barcelona, Spain
| | - Pedro Brotons
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud (CIBERESP), Madrid, Spain
- School of Medicine and Health Sciences, Universitat Internacional de Catalunya, Barcelona, Spain
| | | | - Francisco José Cambra
- Paediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain
| | - Mònica Balaguer
- Paediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain.
- Immunological and Respiratory Disorders in the Pediatric Critical Patient Research Group, Institut de Recerca Sant Joan de Déu, University of Barcelona, Barcelona, Spain.
- Pediatric Infectious Diseases Research Group, Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llogregat, Spain.
| | - Iolanda Jordan
- Paediatric Intensive Care Unit, Hospital Sant Joan de Déu, University of Barcelona, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain
- Immunological and Respiratory Disorders in the Pediatric Critical Patient Research Group, Institut de Recerca Sant Joan de Déu, University of Barcelona, Barcelona, Spain
- Pediatric Infectious Diseases Research Group, Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llogregat, Spain
- Consorcio de Investigación Biomédica en Red de Epidemiología y Salud (CIBERESP), Madrid, Spain
| |
Collapse
|
2
|
Onyije FM, Dolatkhah R, Olsson A, Bouaoun L, Deltour I, Erdmann F, Bonaventure A, Scheurer ME, Clavel J, Schüz J. Risk factors for childhood brain tumours: A systematic review and meta-analysis of observational studies from 1976 to 2022. Cancer Epidemiol 2024; 88:102510. [PMID: 38056243 PMCID: PMC10835339 DOI: 10.1016/j.canep.2023.102510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/24/2023] [Accepted: 11/27/2023] [Indexed: 12/08/2023]
Abstract
BACKGROUND Childhood brain tumours (CBTs) are the leading cause of cancer death in children under the age of 20 years globally. Though the aetiology of CBT remains poorly understood, it is thought to be multifactorial. We aimed to synthesize potential risk factors for CBT to inform primary prevention. METHODS We conducted a systematic review and meta-analysis of epidemiological studies indexed in the PubMed, Web of Science, and Embase databases from the start of those resources through 27 July 2023. We included data from case-control or cohort studies that reported effect estimates for each risk factor around the time of conception, during pregnancy and/or during post-natal period. Random effects meta-analysis was used to estimate summary effect sizes (ES) and 95% confidence intervals (CIs). We also quantified heterogeneity (I2) across studies. FINDINGS A total of 4040 studies were identified, of which 181 studies (85 case-control and 96 cohort studies) met our criteria for inclusion. Of all eligible studies, 50% (n = 91) were conducted in Europe, 32% (n = 57) in North America, 9% (n = 16) in Australia, 8% (n = 15) in Asia, 1% (n = 2) in South America, and none in Africa. We found associations for some modifiable risk factors including childhood domestic exposures to insecticides (ES 1.44, 95% CI 1.20-1.73) and herbicides (ES 2.38, 95% CI 1.31-4.33). Maternal domestic exposure to insecticides (ES 1.45, 95% CI 1.09-1.94), maternal consumption of cured meat (ES 1.51, 95% CI 1.05-2.17) and coffee ≥ 2 cups/day (ES 1.45, 95% 95% CI 1.07-1.95) during pregnancy, and maternal exposure to benzene (ES 2.22; 95% CI 1.01-4.88) before conception were associated with CBTs in case-control studies. Also, paternal occupational exposure to pesticides (ES 1.48, 95% CI 1.23-1.77) and benzene (ES 1.74, 95% CI 1.10-2.76) before conception and during pregnancy were associated in case-control studies and in combined analysis. On the other hand, assisted reproductive technology (ART) (ES 1.32, 95% CI 1.05-1.67), caesarean section (CS) (ES 1.12, 95% CI 1.01-1.25), paternal occupational exposure to paint before conception (ES 1.56, 95% CI 1.02-2.40) and maternal smoking > 10 cigarettes per day during pregnancy (ES 1.18, 95% CI 1.00-1.40) were associated with CBT in cohort studies. Maternal intake of vitamins and folic acid during pregnancy was inversely associated in cohort studies. Hormonal/infertility treatment, breastfeeding, child day-care attendance, maternal exposure to electric heated waterbed, tea and alcohol consumption during pregnancy were among those not associated with CBT in both case-control and cohort studies. CONCLUSION Our results should be interpreted with caution, especially as most associations between risk factors and CBT were discordant between cohort and case-control studies. At present, it is premature for any CBT to define specific primary prevention guidelines.
Collapse
Affiliation(s)
- Felix M Onyije
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France.
| | - Roya Dolatkhah
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France
| | - Ann Olsson
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France
| | - Liacine Bouaoun
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France
| | - Isabelle Deltour
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France
| | - Friederike Erdmann
- Research Group Aetiology and Inequalities in Childhood Cancer, Division of Childhood Cancer Epidemiology Institute of Medical Biostatistics, Epidemiology, and Informatics (IMBEI), University Medical Center Mainz, Langenbeckstraβe 1, 55131 Mainz, Germany
| | - Audrey Bonaventure
- Epidemiology of Childhood and Adolescent Cancers Team, Université Paris Cité and Université Sorbonne Paris Nord, Inserm, INRAE, Center for Research in Epidemiology and StatisticS (CRESS), Villejuif, France
| | - Michael E Scheurer
- Department of Pediatrics, Hematology-Oncology, Baylor College of Medicine and Texas Children's Hospital Cancer Center, Houston, TX, United States
| | - Jacqueline Clavel
- Epidemiology of Childhood and Adolescent Cancers Team, Université Paris Cité and Université Sorbonne Paris Nord, Inserm, INRAE, Center for Research in Epidemiology and StatisticS (CRESS), Villejuif, France; National Registry of Childhood Cancers, Hôpital Paul Brousse, Groupe Hospitalier Universitaire Paris-Sud, Assistance Publique Hôpitaux de Paris (AP-HP), Villejuif, France; Centre Hospitalier Régional Universitaire de Nancy, Vandoeuvre-lès-Nancy, France
| | - Joachim Schüz
- Environment and Lifestyle Epidemiology Branch, International Agency for Research on Cancer (IARC/WHO), 25 avenue Tony Garnier, CS 90627, 69366 LYON CEDEX 07, France
| |
Collapse
|
3
|
Little MP, Wakeford R, Bouffler SD, Abalo K, Hauptmann M, Hamada N, Kendall GM. Cancer risks among studies of medical diagnostic radiation exposure in early life without quantitative estimates of dose. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 832:154723. [PMID: 35351505 PMCID: PMC9167801 DOI: 10.1016/j.scitotenv.2022.154723] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/22/2022] [Accepted: 03/17/2022] [Indexed: 04/14/2023]
Abstract
BACKGROUND There is accumulating evidence of excess risk of cancer in various populations exposed at acute doses below several tens of mSv or doses received over a protracted period. There is also evidence that relative risks are generally higher after radiation exposures in utero or in childhood. METHODS AND FINDINGS We reviewed and summarised evidence from 89 studies of cancer following medical diagnostic exposure in utero or in childhood, in which no direct estimates of radiation dose are available. In all of the populations studied exposure was to sparsely ionizing radiation (X-rays). Several of the early studies of in utero exposure exhibit modest but statistically significant excess risks of several types of childhood cancer. There is a highly significant (p < 0.0005) negative trend of odds ratio with calendar period of study, so that more recent studies tend to exhibit reduced excess risk. There is no significant inter-study heterogeneity (p > 0.3). In relation to postnatal exposure there are significant excess risks of leukaemia, brain and solid cancers, with indications of variations in risk by cancer type (p = 0.07) and type of exposure (p = 0.02), with fluoroscopy and computed tomography scans associated with the highest excess risk. However, there is highly significant inter-study heterogeneity (p < 0.01) for all cancer endpoints and all but one type of exposure, although no significant risk trend with calendar period of study. CONCLUSIONS Overall, this large body of data relating to medical diagnostic radiation exposure in utero provides support for an associated excess risk of childhood cancer. However, the pronounced heterogeneity in studies of postnatal diagnostic exposure, the implied uncertainty as to the meaning of summary measures, and the distinct possibilities of bias, substantially reduce the strength of the evidence from the associations we observe between radiation imaging in childhood and the subsequent risk of cancer being causally related to radiation exposure.
Collapse
Affiliation(s)
- Mark P Little
- Radiation Epidemiology Branch, National Cancer Institute, Bethesda, MD 20892-9778, USA.
| | - Richard Wakeford
- Centre for Occupational and Environmental Health, Faculty of Biology, Medicine and Health, The University of Manchester, Ellen Wilkinson Building, Oxford Road, Manchester M13 9PL, UK
| | - Simon D Bouffler
- Radiation Effects Department, UK Health Security Agency (UKHSA), Chilton, Didcot OX11 0RQ, UK
| | - Kossi Abalo
- Laboratoire d'Épidémiologie, Institut de Radioprotection et de Sûreté Nucléaire, BP 17 92262 Fontenay-aux-Roses Cedex, France
| | - Michael Hauptmann
- Institute of Biostatistics and Registry Research, Brandenburg Medical School Theodor Fontane, Fehrbelliner Strasse 38, 16816 Neuruppin, Germany
| | - Nobuyuki Hamada
- Radiation Safety Unit, Biology and Environmental Chemistry Division, Sustainable System Research Laboratory, Central Research Institute of Electric Power Industry (CRIEPI), 2-11-1 Iwado-kita, Komae, Tokyo 201-8511, Japan
| | - Gerald M Kendall
- Cancer Epidemiology Unit, Oxford Population Health, University of Oxford, Richard Doll Building, Old Road Campus, Headington, Oxford OX3 7LF, UK
| |
Collapse
|
4
|
Chato L, Latifi S. Machine Learning and Radiomic Features to Predict Overall Survival Time for Glioblastoma Patients. J Pers Med 2021; 11:jpm11121336. [PMID: 34945808 PMCID: PMC8705288 DOI: 10.3390/jpm11121336] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 11/24/2021] [Accepted: 12/07/2021] [Indexed: 01/11/2023] Open
Abstract
Glioblastoma is an aggressive brain tumor with a low survival rate. Understanding tumor behavior by predicting prognosis outcomes is a crucial factor in deciding a proper treatment plan. In this paper, an automatic overall survival time prediction system (OST) for glioblastoma patients is developed on the basis of radiomic features and machine learning (ML). This system is designed to predict prognosis outcomes by classifying a glioblastoma patient into one of three survival groups: short-term, mid-term, and long-term. To develop the prediction system, a medical dataset based on imaging information from magnetic resonance imaging (MRI) and non-imaging information is used. A novel radiomic feature extraction method is proposed and developed on the basis of volumetric and location information of brain tumor subregions extracted from MRI scans. This method is based on calculating the volumetric features from two brain sub-volumes obtained from the whole brain volume in MRI images using brain sectional planes (sagittal, coronal, and horizontal). Many experiments are conducted on the basis of various ML methods and combinations of feature extraction methods to develop the best OST system. In addition, the feature fusions of both radiomic and non-imaging features are examined to improve the accuracy of the prediction system. The best performance was achieved by the neural network and feature fusions.
Collapse
|
5
|
Non-Hodgkin lymphomas and ionizing radiation: case report and review of the literature. Ann Hematol 2021; 101:243-250. [PMID: 34881390 PMCID: PMC8742808 DOI: 10.1007/s00277-021-04729-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 11/22/2021] [Indexed: 11/18/2022]
Abstract
Non-Hodgkin lymphoma (NHL) increased continuously since the last century in developed countries. While they are considered as disease in elder ages, a remarkable increasing incidence is also observed in German children and juveniles. The higher rates are interpreted by the changes in classification because diseases such as chronic lymphocytic leukaemia were also identified as NHL. Considerable rates of NHL were found in nuclear workers and liquidators of Chernobyl, i.e. in cases of low-dose chronical exposures. In Germany, we noticed three workers who developed NHL after decontamination of nuclear facilities. The bone marrow is generally considered as target organ for ionizing radiation, but NHL is obviously induced in the whole pool of lymphocytes. Therefore, the dosimetry in cases of typical occupational external and internal exposure must be revised. A high radiation sensitivity for NHL is a possible suspect and likely reason which may partly explain the continuous rise of the diseases in populations underlying the current increases of medical diagnostic exposure. NHL is also induced in children and juveniles with a history of diagnostic X-rays.
Collapse
|
6
|
Dudwiesus H, Merz E. How safe is it to use ultrasound in prenatal medicine? Facts and contradictions - Part 2 - Laboratory experiments regarding non-thermal effects and epidemiological studies. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2021; 42:460-502. [PMID: 33836546 DOI: 10.1055/a-1394-6194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The first part of this CME article (issue 5/20) provided a detailed examination of the biophysical effects of ultrasound waves, the exposure values, and in particular the thermal effect. In vivo and in vitro measurements have shown that the temperature increase in tissue associated with B-mode ultrasound is far too low to pose a potential risk. Even experiments with exposure values in the range of pulsed Doppler have shown that temperature increases of over 1.5 °C can only occur in areas in direct contact with the probe, thus making a limited exposure time particularly in the case of transvaginal application advisable. The second part of this CME article describes various laboratory and animal experiments for evaluating non-thermal effects and also presents the most important epidemiological studies in the last 30 years in the form of an overview and review. In addition to direct insonation of isolated cells to examine possible mutagenic effects, the blood of patients exposed in vivo to ultrasound was also analyzed in multiple experiments. Reproducible chromosome aberrations could not be found in any of the studies. In contrast, many experiments on pregnant rodents showed some significant complications, such as abortion, deformities, and behavioral disorders. As in the case of thermal effects, the results of these experiments indicate the presence of an intensity- or pressure-dependent effect threshold. Numerous epidemiological studies examining possible short-term and long-term consequences after intrauterine ultrasound exposure are available with the most important studies being discussed in the following. In contrast to information presented incorrectly in the secondary literature and in the lay press, health problems could not be seen in the children observed in the postpartum period in any of these studies.
Collapse
Affiliation(s)
| | - Eberhard Merz
- Centre for Ultrasound and Prenatal Medicine Frankfurt/Main, Germany
| |
Collapse
|
7
|
Evaluation of Risk Factors for Pediatric Cancers in the West of Iran. INTERNATIONAL JOURNAL OF CANCER MANAGEMENT 2021. [DOI: 10.5812/ijcm.113496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: Occurrence of pediatric cancers is affected by maternal, environmental, and hereditary/genetic factors. Objectives: The purpose of this study was to evaluate the correlation between background radiation, ultrasound and other possible risk factors for pediatric cancers incidence indicators. Methods: In a cross-sectional study during 2 years, 103 patients under 14 years were studied. A total of 13 environmental, maternal and hereditary/genetic risk factors were studied, and the study was performed by using a questionnaire, measurement of background radiation, and statistical data. Incidence in the studied sample size at city (ISSSC) and incidence in the studied sample size at area (ISSSA) indicators were defined. Results: The mean age of patients was (6.31 ± 3.22) including 54 (52.4%) males and 49 (47.6%) females. History of repeated ultrasound before gender determination (RUBGD) and repeated ultrasound during pregnancy (RUDP) were statistically higher in solid tumors group. Toxic substances (TS) and pediatric medical ionizing radiation (PMIR) was higher in hematologic malignancies. Statistically significant association were found between of cancer types and Family history of leukemia (FHL), Family history of solid tumors (FHST), Abortion history (AH), Maternal smoking during pregnancy (MSDP), Children’s residence place (CRP), and background radiation (BR) variables. No statistically significant association was found between cancer types and maternal pregnancy age (MPA), IVF baby, and maternal ionizing radiation exposure (MIRE) variables. Conclusions: Pediatric cancers are multifactorial diseases. Increased background radiation is correlated with an increased incidence of all pediatric malignancies. It seems that increasing ultrasound scans might increase the risk of solid tumors in children.
Collapse
|
8
|
Wakeford R, Bithell JF. A review of the types of childhood cancer associated with a medical X-ray examination of the pregnant mother. Int J Radiat Biol 2021; 97:571-592. [PMID: 33787450 DOI: 10.1080/09553002.2021.1906463] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE For 65 years the interpretation of the statistical association between the risk of cancer in a child and a prior diagnostic X-ray examination of the abdomen of the pregnant mother has been debated. The objections to a direct cause-and-effect explanation of the association vary in their strength, but one of the most notable grounds for controversy is the finding from the first and largest case-control study reporting the association, the Oxford Survey of Childhood Cancers (OSCC), of an almost uniformly raised relative risk (RR) for nearly all of the types of cancer that are most frequent in children. Here we compare the antenatal X-ray associations found in the OSCC for different types of childhood cancer with the results of all other case-control and case-cohort studies appropriately combined in meta-analyses, and we also review the findings of the few cohort studies that have been conducted. CONCLUSIONS From the case-control/case-cohort studies other than the OSCC there are consistent and clear elevations of risk for all types of childhood cancer combined, all leukemia, and all cancers except leukemia combined. This compatibility of the findings of the OSCC with those of the combined other studies is less clear, or effectively absent, when some categories containing smaller numbers of incident cases/deaths are considered, but lack of precision of risk estimates due to sparse data presents inferential challenges, although there is a consistent absence of an association for bone tumors. Further, more recent studies almost certainly address lower intrauterine doses, with an anticipated decrease in estimated risks, which could be misleading when comparisons involve a limited number of studies that are mainly from later years, and a similar problem arises when having to employ all types of antenatal X-ray exposures for a study because data for abdominal exposures are absent. The problem of low statistical power is greater for cohort studies, and this, together with other shortcomings identified in the studies, limits the interpretational value of results. The findings of non-medical intrauterine exposure studies are constrained by sparse data and make a limited contribution to an understanding of the association. Certain aspects of the various studies require a need for caution in interpretation, but overall, the appropriate combination of all case-control/case-cohort studies other than the OSCC lends support to the inference that low-level exposure to radiation in utero proportionally increases the risk of the typical cancers of childhood to around the same level.
Collapse
Affiliation(s)
- Richard Wakeford
- Centre for Occupational and Environmental Health, The University of Manchester, Manchester, UK
| | - John F Bithell
- Department of Statistics, University of Oxford, Oxford, UK
| |
Collapse
|
9
|
Harbron RW, Pasqual E. Ionising radiation as a risk factor for lymphoma: a review. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2020; 40:R151-R185. [PMID: 33017815 DOI: 10.1088/1361-6498/abbe37] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Accepted: 10/05/2020] [Indexed: 06/11/2023]
Abstract
The ability of ionising radiation to induce lymphoma is unclear. Here, we present a narrative review of epidemiological evidence of the risk of lymphoma, including chronic lymphocytic leukaemia (CLL) and multiple myeloma (MM), among various exposed populations including atomic bombing survivors, industrial and medical radiation workers, and individuals exposed for medical purposes. Overall, there is a suggestion of a positive dose-dependent association between radiation exposure and lymphoma. The magnitude of this association is highly imprecise, however, with wide confidence intervals frequently including zero risk. External comparisons tend to show similar incidence and mortality rates to the general population. Currently, there is insufficient information on the impact of age at exposure, high versus low linear energy transfer radiation, external versus internal or acute versus chronic exposures. Associations are stronger for males than females, and stronger for non-Hodgkin lymphoma and MM than for Hodgkin lymphoma, while the risk of radiation-induced CLL may be non-existent. This broad grouping of diverse diseases could potentially obscure stronger associations for certain subtypes, each with a different cell of origin. Additionally, the classification of malignancies as leukaemia or lymphoma may result in similar diseases being analysed separately, while distinct diseases are analysed in the same category. Uncertainty in cell of origin means the appropriate organ for dose response analysis is unclear. Further uncertainties arise from potential confounding or bias due to infectious causes and immunosuppression. The potential interaction between radiation and other risk factors is unknown. Combined, these uncertainties make lymphoma perhaps the most challenging malignancy to study in radiation epidemiology.
Collapse
Affiliation(s)
- Richard W Harbron
- Population Health Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom
- NIHR Health Protection Research Unit in Chemical and Radiation Threats and Hazards, Newcastle University, United Kingdom
- Barcelona Institute for Global Health, (ISGlobal), Barcelona, Spain
- Universitat Pompeu Fabra (UPF), Barcelona, Spain
- CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| | - Elisa Pasqual
- Barcelona Institute for Global Health, (ISGlobal), Barcelona, Spain
- Universitat Pompeu Fabra (UPF), Barcelona, Spain
- CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| |
Collapse
|
10
|
Kharasch S, Duggan NM, Cohen AR, Shokoohi H. Lung Ultrasound in Children with Respiratory Tract Infections: Viral, Bacterial or COVID-19? A Narrative Review. Open Access Emerg Med 2020; 12:275-285. [PMID: 33116963 PMCID: PMC7569078 DOI: 10.2147/oaem.s238702] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 09/18/2020] [Indexed: 12/18/2022] Open
Abstract
Respiratory tract infections (RTIs) are common complaints among patients presenting to the pediatric emergency department. In the diagnostic assessment of children with RTIs, many patients ultimately undergo imaging studies for further evaluation. Point-of-care lung ultrasound (LUS) can be used safely and with a high degree of accuracy in differentiating etiologies of RTIs in pediatric patients. Ultrasonographical features such as an irregular pleural line, subpleural consolidations, focal and lobar consolidation and signs of interstitial involvement can be used to distinguish between several pathologies. This work offers a comprehensive overview of pediatric LUS in cases of the most common pediatric RTIs including bacterial and viral pneumonia, bronchiolitis, and COVID-19.
Collapse
Affiliation(s)
- Sigmund Kharasch
- Division of Pediatric Emergency Medicine, Division of Emergency Ultrasound, Department of Pediatrics, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Nicole M Duggan
- Harvard Affiliated Emergency Medicine Residency Program, Harvard Medical School, Boston, MA, USA
| | - Ari R Cohen
- Division of Pediatric Emergency Medicine, Department of Emergency Medicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| | - Hamid Shokoohi
- Division of Emergency Ultrasound, Department of Emergency Medicine, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
11
|
Jaszczołt S, Polewczyk T, Dołęga-Kozierowska M, Woźniak M, Doniec Z. Comparison of lung ultrasound and chest X-ray findings in children with bronchiolitis. J Ultrason 2018; 18:193-197. [PMID: 30427130 PMCID: PMC6442216 DOI: 10.15557/jou.2018.0029] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/10/2018] [Indexed: 11/22/2022] Open
Abstract
Aim Respiratory syncytial virus is the main pathogen responsible for bronchiolitis. Usually, there is no indication to perform diagnostic imaging or run laboratory tests in patients with bronchiolitis since the diagnosis is based on the clinical presentation. Chest radiogram can be useful in severe cases. So far, lung ultrasound has not been considered as an alternative in guidelines for imaging diagnosis of bronchiolitis. The aim of the study was to compare lung ultrasound and chest X-ray findings in children with bronchiolitis. Material and methods In our study we retrospectively compared diagnostic imaging findings in children with confirmed respiratory syncytial virus infection. The study included 23 children aged 2 weeks to 24 months and 3 children older than 24 months. Results Chest X-ray showed lesions in only 4 cases, whereas ultrasound abnormalities were found in 21 patients. Pathologies revealed by chest X-ray were the same for all 4 cases and consisted of an enlarged hilus and peribronchial cuffing. Sonographic lesions included inflammatory consolidations larger than 10 mm in 11 patients, small consolidations (<10 mm diameter) in 8 patients, interstitial syndromes in 6 patients, and alveolar-interstitial syndromes in 11 patients. A small amount of pleural effusion was detected in 3 patients. Conclusions Considering safety, short time of examination, high sensitivity in finding pleural effusion, small consolidations and signs of interstitial infiltrations, transthoracic lung ultrasound may be useful in the diagnosis of bronchiolitis.
Collapse
Affiliation(s)
- Sławomir Jaszczołt
- Department of Pediatric Neuroinfections and Neurology, John Paul II Specialty Hospital in Cracow, Poland
| | - Tomasz Polewczyk
- Department of Radiology, Institute of Tuberculosis and Lung Diseases, Rabka-Zdrój Branch, Poland
| | - Marta Dołęga-Kozierowska
- Department of Allergology, Institute of Tuberculosis and Lung Diseases, Rabka-Zdrój Branch, Poland
| | - Mariusz Woźniak
- Department of Pneumonology, Institute of Tuberculosis and Lung Diseases, Rabka-Zdrój Branch, Poland
| | - Zbigniew Doniec
- Department of Pneumonology, Institute of Tuberculosis and Lung Diseases, Rabka-Zdrój Branch, Poland
| |
Collapse
|
12
|
Automated Risk Control in Medical Imaging Equipment Management Using Cloud Application. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:7125258. [PMID: 29854362 PMCID: PMC5954869 DOI: 10.1155/2018/7125258] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2017] [Accepted: 04/10/2018] [Indexed: 11/18/2022]
Abstract
Medical imaging equipment (MIE) is the baseline of providing patient diagnosis in healthcare facilities. However, that type of equipment poses high risk for patients, operators, and environment in terms of technology and application. Considering risk management in MIE management is rarely covered in literature. The study proposes a methodology that controls risks associated with MIE management. The methodology is based on proposing a set of key performance indicators (KPIs) that lead to identify a set of undesired events (UDEs), and through a risk matrix, a risk level is evaluated. By using cloud computing software, risks could be controlled to be manageable. The methodology was verified by using a data set of 204 pieces of MIE along 104 hospitals, which belong to Egyptian Ministry of Health. Results point to appropriateness of proposed KPIs and UDEs in risk evaluation and control. Thus, the study reveals that optimizing risks taking into account the costs has an impact on risk control of MIE management.
Collapse
|
13
|
Abstract
The use of diagnostic medical imaging is becoming increasingly more commonplace in the pediatric setting. However, many medical imaging modalities expose pediatric patients to ionizing radiation, which has been shown to increase the risk of cancer development in later life. This review article provides a comprehensive overview of the available data regarding the risk of cancer development following exposure to ionizing radiation from diagnostic medical imaging. Attention is paid to modalities such as computed tomography scans and fluoroscopic procedures that can expose children to radiation doses orders of magnitude higher than standard diagnostic x-rays. Ongoing studies that seek to more precisely determine the relationship of diagnostic medical radiation in children and subsequent cancer development are discussed, as well as modern strategies to better quantify this risk. Finally, as cardiovascular imaging and intervention contribute substantially to medical radiation exposure, we discuss strategies to enhance radiation safety in these areas.
Collapse
|
14
|
Radiographic Evaluation During Treatment of Pediatric Forearm Fractures: Implications on Clinical Care and Cost. J Pediatr Orthop 2017; 36:465-71. [PMID: 25887819 DOI: 10.1097/bpo.0000000000000479] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND As ≥30% of displaced pediatric forearm fractures demonstrate loss of reduction (LOR) following closed reduction (CR); radiographic follow-up is advocated at 1, 2, 4, and 6 weeks for detection of redisplacement. We hypothesized that there is minimal change in fracture alignment 2 weeks after CR, and consequently, that radiographs at 4 weeks add cost but little value to clinical care. METHODS A total of 184 patients enrolled in a prospective study of pediatric forearm fractures including both distal and diaphyseal injuries were evaluated. All were treated with CR, casting, and radiographic evaluation at 1, 2, 4, and 6 weeks postinjury. Primary endpoint was radiographic LOR. Secondary endpoint was need for any intervention. A modified number-needed to treat analysis estimated the utility of the week 4 x-ray in predicting intervention. Relative value unit (RVU) costing, time-derived activity-based costing (TDABC), and billing totals were used for cost analysis. RESULTS Seventy patients (38%) demonstrated radiographic LOR. Independent predictors of LOR were initial radius displacement >75% (OR=5.40; CI, 2.23-12.60), concomitant ulna fracture (OR=1.71; CI, 1.15-2.54), and dominant arm involvement (OR=2.87; CI, 1.40-5.87). Eighty percent of all LORs occurred within the first 2 weeks. There was no statistically significant change in radiographic alignment after week 2. Of 40 total interventions, all were performed within the first 2 weeks of follow-up. The 4-week x-ray did not influence decision to intervene, and at most, 1 in every 40 patients would require an intervention after week 2. Elimination of the 4-week x-ray would result in a savings of 4.8% (RVU method) to 11.9% (TDABC method) in the overall cost of nonoperative fracture care. CONCLUSIONS There is minimal change in fracture alignment 2 weeks following CR of pediatric forearm fractures, and all interventions are based on early radiographic follow-up. The week 4 x-ray adds little value to clinical decision making, and its elimination would result in savings up to 11.9% of the overall cost of nonoperative fracture care. LEVEL OF EVIDENCE Level II-prognostic.
Collapse
|
15
|
ICNIRP Statement on Diagnostic Devices Using Non-ionizing Radiation: Existing Regulations and Potential Health Risks. HEALTH PHYSICS 2017; 112:305-321. [PMID: 28121732 PMCID: PMC5515634 DOI: 10.1097/hp.0000000000000654] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Use of non-ionizing radiation (NIR) for diagnostic purposes allows non-invasive assessment of the structure and function of the human body and is widely employed in medical care. ICNIRP has published previous statements about the protection of patients during medical magnetic resonance imaging (MRI), but diagnostic methods using other forms of NIR have not been considered. This statement reviews the range of diagnostic NIR devices currently used in clinical settings; documents the relevant regulations and policies covering patients and health care workers; reviews the evidence around potential health risks to patients and health care workers exposed to diagnostic NIR; and identifies situations of high NIR exposure from diagnostic devices in which patients or health care workers might not be adequately protected by current regulations. Diagnostic technologies were classified by the types of NIR that they employ. The aim was to describe the techniques in terms of general device categories which may encompass more specific devices or techniques with similar scientific principles. Relevant legally-binding regulations for protection of patients and workers and organizations responsible for those regulations were summarized. Review of the epidemiological evidence concerning health risks associated with exposure to diagnostic NIR highlighted a lack of data on potential risks to the fetus exposed to MRI during the first trimester, and on long-term health risks in workers exposed to MRI. Most of the relevant epidemiological evidence that is currently available relates to MRI or ultrasound. Exposure limits are needed for exposures from diagnostic technologies using optical radiation within the body. There is a lack of data regarding risk of congenital malformations following exposure to ultrasound in utero in the first trimester and also about the possible health effects of interactions between ultrasound and contrast media.
Collapse
|
16
|
Jain V, Chari R, Maslovitz S, Farine D. Lignes directrices pour la prise en charge d'une patiente enceinte ayant subi un traumatisme. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2017; 38:S665-S687. [PMID: 28063573 DOI: 10.1016/j.jogc.2016.09.070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
17
|
Evaluation and Monitoring of a Child With Hydrocarbon Pneumonitis Using Point-of-Care Lung Ultrasound in the Pediatric Emergency Department. Pediatr Emerg Care 2016; 32:642-4. [PMID: 26890296 DOI: 10.1097/pec.0000000000000641] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
A well-appearing 3-year-old boy presented to the pediatric emergency department 2 hours after a presumed hydrocarbon ingestion. He was referred to the emergency department by his pediatrician after consultation with the local poison control center after possibly ingesting ylang ylang (Cananga odorata) fragrance oil. The child was asymptomatic with a normal physical examination. Point-of-care lung ultrasound identified focal hydrocarbon pneumonitis in the right lung and demonstrated resolution of these findings. Utilization of point-of-care ultrasound resulted in a shorter emergency department length of stay and the avoidance of radiation exposure from serial chest x-rays.
Collapse
|
18
|
Gunn ML, Marin JR, Mills AM, Chong ST, Froemming AT, Johnson JO, Kumaravel M, Sodickson AD. A report on the Academic Emergency Medicine 2015 consensus conference “Diagnostic imaging in the emergency department: a research agenda to optimize utilization”. Emerg Radiol 2016; 23:383-96. [DOI: 10.1007/s10140-016-1398-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Accepted: 04/12/2016] [Indexed: 11/29/2022]
|
19
|
Jones BP, Tay ET, Elikashvili I, Sanders JE, Paul AZ, Nelson BP, Spina LA, Tsung JW. Feasibility and Safety of Substituting Lung Ultrasonography for Chest Radiography When Diagnosing Pneumonia in Children: A Randomized Controlled Trial. Chest 2016; 150:131-8. [PMID: 26923626 DOI: 10.1016/j.chest.2016.02.643] [Citation(s) in RCA: 134] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2015] [Revised: 01/08/2016] [Accepted: 02/02/2016] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Chest radiography (CXR) is the test of choice for diagnosing pneumonia. Lung ultrasonography (LUS) has been shown to be accurate for diagnosing pneumonia in children and may be an alternative to CXR. Our objective was to determine the feasibility and safety of substituting LUS for CXR when evaluating children suspected of having pneumonia. METHODS We conducted a randomized control trial comparing LUS with CXR in 191 children from birth to 21 years of age suspected of having pneumonia in an ED. Patients in the investigational arm underwent LUS. If there was clinical uncertainty after ultrasonography, physicians had the option to perform CXR. Patients in the control arm underwent sequential imaging with CXR followed by LUS. The primary outcome was the rate of CXR reduction; secondary outcomes were missed pneumonia, subsequent unscheduled health-care visits, and adverse events between the investigational and control arms. RESULTS There was a 38.8% reduction (95% CI, 30.0%-48.9%) in CXR among investigational subjects compared with no reduction (95% CI, 0.0%-3.6%) in the control group. Novice and experienced physician-sonologists achieved 30.0% and 60.6% reduction in CXR use, respectively. There were no cases of missed pneumonia among all study participants (investigational arm, 0.0%: 95% CI, 0.0%-2.9%; control arm, 0.0%: 95% CI, 0.0%-3.0%), or differences in adverse events, or subsequent unscheduled health-care visits between arms. CONCLUSIONS It may be feasible and safe to substitute LUS for CXR when evaluating children suspected of having pneumonia with no missed cases of pneumonia or increase in rates of adverse events. TRIAL REGISTRY ClinicalTrials.gov; No.: NCT01654887; URL: www.clinicaltrials.gov.
Collapse
Affiliation(s)
- Brittany Pardue Jones
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Ee Tein Tay
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY; Division of Emergency Ultrasound, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Inna Elikashvili
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Jennifer E Sanders
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Audrey Z Paul
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Bret P Nelson
- Division of Emergency Ultrasound, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Louis A Spina
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY
| | - James W Tsung
- Division of Pediatric Emergency Medicine, Icahn School of Medicine at Mount Sinai, New York, NY; Division of Emergency Ultrasound, Icahn School of Medicine at Mount Sinai, New York, NY.
| |
Collapse
|
20
|
Kang JW, Do KH, Han K, Chae EJ, Yang DH, Lee CW. Survey of Thoracic CT Protocols and Technical Parameters in Korean Hospitals: Changes before and after Establishment of Thoracic CT Guideline by Korean Society of Thoracic Radiology in 2008. J Korean Med Sci 2016; 31 Suppl 1:S32-7. [PMID: 26908985 PMCID: PMC4756339 DOI: 10.3346/jkms.2016.31.s1.s32] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 12/14/2015] [Indexed: 11/22/2022] Open
Abstract
We retrospectively reviewed the thoracic CT scan protocols and technical parameters obtained from hospitals in Korea, one group during May 2007 (n = 100) and the other group during January 2012 (n = 173), before and after the establishment of the thoracic CT Guideline in 2008. Each group was also divided into two subgroups according to the health care delivery level, i.e. the "A" subgroup from primary and the "B" subgroup from secondary and tertiary care hospitals. When comparing the data from 2007 and 2012, the tube current decreased from 179.1 mAs to 137.2 mAs. The scan interval decreased from 6.4 mm to 4.8 mm. Also, the insufficient scan range decreased from 19.0% to 8.7%, and the suboptimal quality scans decreased from 33.0% to 5.2%. Between groups A and B, group B had lower tube voltages, smaller scan thicknesses, and smaller scan intervals. However, group B had more phase numbers. In terms of the suboptimal quality scans, a decrease was seen in both groups. In conclusion, during the five-year time period between 2007 and 2012, a reduction in the tube current values was seen. And the overall image quality improved over the same time period. We assume that these changes are attributed to the implementation of the thoracic CT guideline in 2008.
Collapse
Affiliation(s)
- Ji-Won Kang
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| | - Kyung-Hyun Do
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| | - Kichang Han
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| | - Eun-Jin Chae
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| | - Dong-Hyun Yang
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| | - Choong-Wook Lee
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
21
|
Moore CL, Broder J, Gunn ML, Bhargavan-Chatfield M, Cody D, Cullison K, Daniels B, Gans B, Kennedy Hall M, Gaines BA, Goldman S, Heil J, Liu R, Marin JR, Melnick ER, Novelline RA, Pare J, Repplinger MD, Taylor RA, Sodickson AD. Comparative Effectiveness Research: Alternatives to "Traditional" Computed Tomography Use in the Acute Care Setting. Acad Emerg Med 2015; 22:1465-73. [PMID: 26576033 DOI: 10.1111/acem.12831] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Accepted: 07/12/2015] [Indexed: 01/07/2023]
Abstract
Computed tomography (CT) scanning is an essential diagnostic tool and has revolutionized care of patients in the acute care setting. However, there is widespread agreement that overutilization of CT, where benefits do not exceed possible costs or harms, is occurring. The goal was to seek consensus in identifying and prioritizing research questions and themes that involve the comparative effectiveness of "traditional" CT use versus alternative diagnostic strategies in the acute care setting. A modified Delphi technique was used that included input from emergency physicians, emergency radiologists, medical physicists, and an industry expert to achieve this.
Collapse
Affiliation(s)
- Christopher L. Moore
- Department of Emergency Medicine; Yale University School of Medicine; New Haven CT
| | - Joshua Broder
- Department of Surgery; Section of Emergency Medicine; Duke University; Durham NC
| | - Martin L. Gunn
- Department of Radiology; University of Washington; Seattle WA
| | | | - Dianna Cody
- Department of Imaging Physics; University of Texas Houston; Houston TX
| | - Kevin Cullison
- Department of Emergency Medicine; Washington University; St. Louis MO
| | - Brock Daniels
- Department of Emergency Medicine; University of California Davis; Davis CA
| | - Bradley Gans
- Department of Radiology; Ohio State University; Cleveland WA
| | - M. Kennedy Hall
- Department of Emergency Medicine; University of Washington; Seattle WA
| | - Barbara A. Gaines
- Division of Pediatric General and Thoracic Surgery; University of Pittsburgh School of Medicine; Pittsburgh PA
| | - Sarah Goldman
- Department of Emergency Medicine; Jacobi Medical Center; New York NY
| | - John Heil
- medint Holdings; LLC d.b.a Imalogix; King of Prussia PA
| | - Rachel Liu
- Department of Emergency Medicine; Yale University School of Medicine; New Haven CT
| | - Jennifer R. Marin
- Departments of Pediatrics and Emergency Medicine; University of Pittsburgh School of Medicine; Pittsburgh PA
- Department of Pediatrics; University of Pittsburgh School of Medicine; Pittsburgh PA
| | - Edward R. Melnick
- Department of Emergency Medicine; Yale University School of Medicine; New Haven CT
| | | | - Joseph Pare
- Department of Emergency Medicine; Yale University School of Medicine; New Haven CT
| | - Michael D. Repplinger
- Departments of Emergency Medicine and Radiology; University of Wisconsin School of Medicine and Public Health; Madison WI
| | - Richard A. Taylor
- Department of Emergency Medicine; Yale University School of Medicine; New Haven CT
| | | |
Collapse
|
22
|
Jain V, Chari R, Maslovitz S, Farine D, Bujold E, Gagnon R, Basso M, Bos H, Brown R, Cooper S, Gouin K, McLeod NL, Menticoglou S, Mundle W, Pylypjuk C, Roggensack A, Sanderson F. Guidelines for the Management of a Pregnant Trauma Patient. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2015; 37:553-74. [PMID: 26334607 DOI: 10.1016/s1701-2163(15)30232-2] [Citation(s) in RCA: 97] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Physical trauma affects 1 in 12 pregnant women and has a major impact on maternal mortality and morbidity and on pregnancy outcome. A multidisciplinary approach is warranted to optimize outcome for both the mother and her fetus. The aim of this document is to provide the obstetric care provider with an evidence-based systematic approach to the pregnant trauma patient. OUTCOMES Significant health and economic outcomes considered in comparing alternative practices. EVIDENCE Published literature was retrieved through searches of Medline, CINAHL, and The Cochrane Library from October 2007 to September 2013 using appropriate controlled vocabulary (e.g., pregnancy, Cesarean section, hypotension, domestic violence, shock) and key words (e.g., trauma, perimortem Cesarean, Kleihauer-Betke, supine hypotension, electrical shock). Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies published in English between January 1968 and September 2013. Searches were updated on a regular basis and incorporated in the guideline to February 2014. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. VALUES The quality of evidence in this document was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). BENEFITS, HARMS, AND COSTS This guideline is expected to facilitate optimal and uniform care for pregnancies complicated by trauma. Summary Statement Specific traumatic injuries At this time, there is insufficient evidence to support the practice of disabling air bags for pregnant women. (III) Recommendations Primary survey 1. Every female of reproductive age with significant injuries should be considered pregnant until proven otherwise by a definitive pregnancy test or ultrasound scan. (III-C) 2. A nasogastric tube should be inserted in a semiconscious or unconscious injured pregnant woman to prevent aspiration of acidic gastric content. (III-C) 3. Oxygen supplementation should be given to maintain maternal oxygen saturation > 95% to ensure adequate fetal oxygenation. (II-1B) 4. If needed, a thoracostomy tube should be inserted in an injured pregnant woman 1 or 2 intercostal spaces higher than usual. (III-C) 5. Two large bore (14 to 16 gauge) intravenous lines should be placed in a seriously injured pregnant woman. (III-C) 6. Because of their adverse effect on uteroplacental perfusion, vasopressors in pregnant women should be used only for intractable hypotension that is unresponsive to fluid resuscitation. (II-3B) 7. After mid-pregnancy, the gravid uterus should be moved off the inferior vena cava to increase venous return and cardiac output in the acutely injured pregnant woman. This may be achieved by manual displacement of the uterus or left lateral tilt. Care should be taken to secure the spinal cord when using left lateral tilt. (II-1B) 8. To avoid rhesus D (Rh) alloimmunization in Rh-negative mothers, O-negative blood should be transfused when needed until cross-matched blood becomes available. (I-A) 9. The abdominal portion of military anti-shock trousers should not be inflated on a pregnant woman because this may reduce placental perfusion. (II-3B) Transfer to health care facility 10. Transfer or transport to a maternity facility (triage of a labour and delivery unit) is advocated when injuries are neither life- nor limb-threatening and the fetus is viable (≥ 23 weeks), and to the emergency room when the fetus is under 23 weeks' gestational age or considered to be non-viable. When the injury is major, the patient should be transferred or transported to the trauma unit or emergency room, regardless of gestational age. (III-B) 11. When the severity of injury is undetermined or when the gestational age is uncertain, the patient should be evaluated in the trauma unit or emergency room to rule out major injuries. (III-C) Evaluation of a pregnant trauma patient in the emergency room 12. In cases of major trauma, the assessment, stabilization, and care of the pregnant women is the first priority; then, if the fetus is viable (≥ 23 weeks), fetal heart rate auscultation and fetal monitoring can be initiated and an obstetrical consultation obtained as soon as feasible. (II-3B) 13. In pregnant women with a viable fetus (≥ 23 weeks) and suspected uterine contractions, placental abruption, or traumatic uterine rupture, urgent obstetrical consultation is recommended. (II-3B) 14. In cases of vaginal bleeding at or after 23 weeks, speculum or digital vaginal examination should be deferred until placenta previa is excluded by a prior or current ultrasound scan. (III-C) Adjunctive tests for maternal assessment 15. Radiographic studies indicated for maternal evaluation including abdominal computed tomography should not be deferred or delayed due to concerns regarding fetal exposure to radiation. (II-2B) 16. Use of gadolinium-based contrast agents can be considered when maternal benefit outweighs potential fetal risks. (III-C) 17. In addition to the routine blood tests, a pregnant trauma patient should have a coagulation panel including fibrinogen. (III-C) 18. Focused abdominal sonography for trauma should be considered for detection of intraperitoneal bleeding in pregnant trauma patients. (II-3B) 19. Abdominal computed tomography may be considered as an alternative to diagnostic peritoneal lavage or open lavage when intra-abdominal bleeding is suspected. (III-C) Fetal assessment 20. All pregnant trauma patients with a viable pregnancy (≥ 23 weeks) should undergo electronic fetal monitoring for at least 4 hours. (II-3B) 21. Pregnant trauma patients (≥ 23 weeks) with adverse factors including uterine tenderness, significant abdominal pain, vaginal bleeding, sustained contractions (> 1/10 min), rupture of the membranes, atypical or abnormal fetal heart rate pattern, high risk mechanism of injury, or serum fibrinogen < 200 mg/dL should be admitted for observation for 24 hours. (III-B) 22. Anti-D immunoglobulin should be given to all rhesus D-negative pregnant trauma patients. (III-B) 23. In Rh-negative pregnant trauma patients, quantification of maternal-fetal hemorrhage by tests such as Kleihauer-Betke should be done to determine the need for additional doses of anti-D immunoglobulin. (III-B) 24. An urgent obstetrical ultrasound scan should be undertaken when the gestational age is undetermined and need for delivery is anticipated. (III-C) 25. All pregnant trauma patients with a viable pregnancy who are admitted for fetal monitoring for greater than 4 hours should have an obstetrical ultrasound prior to discharge from hospital. (III-C) 26. Fetal well-being should be carefully documented in cases involving violence, especially for legal purposes. (III-C) Obstetrical complications of trauma 27. Management of suspected placental abruption should not be delayed pending confirmation by ultrasonography as ultrasound is not a sensitive tool for its diagnosis. (II-3D) Specific traumatic injuries 28. Tetanus vaccination is safe in pregnancy and should be given when indicated. (II-3B) 29. Every woman who sustains trauma should be questioned specifically about domestic or intimate partner violence. (II-3B) 30. During prenatal visits, the caregiver should emphasize the importance of wearing seatbelts properly at all times. (II-2B) Perimortem Caesarean section 31. A Caesarean section should be performed for viable pregnancies (≥ 23 weeks) no later than 4 minutes (when possible) following maternal cardiac arrest to aid with maternal resuscitation and fetal salvage. (III-B).
Collapse
|
23
|
Lung ultrasound: a useful tool in diagnosis and management of bronchiolitis. BMC Pediatr 2015; 15:63. [PMID: 25993984 PMCID: PMC4494717 DOI: 10.1186/s12887-015-0380-1] [Citation(s) in RCA: 85] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2014] [Accepted: 05/15/2015] [Indexed: 11/30/2022] Open
Abstract
Background Clinical assessment is the gold standard for diagnosis of bronchiolitis. To date, only one study found LUS (Lung Ultrasound) to be a valuable tool in the diagnosis of bronchiolitis. Aim of this study is to evaluate the accuracy of lung ultrasonography in the diagnosis and management of bronchiolitis in infants. Methods This was an observational cohort study of infants admitted to our Pediatric Unit with suspected bronchiolitis. A physical examination and lung ultrasound scans were performed on each patient. Diagnosis and grading of bronchiolitis was assessed according to a clinical and a ultrasound score. An exploratory analysis was used to assess correspondence between the lung ultrasound findings and the clinical evaluation and to evaluate the inter-observer concordance between the two different sonographs. Results One hundred six infants were studied (average age 71 days). According to our clinical score, 74 infants had mild bronchiolitis, 30 had moderate bronchiolitis and two had severe bronchiolitis. 25 infants composed the control group. Agreement between the clinical and sonographic diagnosis was good (90.6 %) with a statistically significant inter-observer ultrasound diagnosis concordance (89.6 %). Lung ultrasound permits the identification of infants who are in need of supplementary oxygen with a specificity of 98.7 %, a sensitivity of 96.6 %, a positive predictive value of 96.6 % and a negative predictive value of 98.7 %. An aberrant ultrasound lung pattern in posterior chest area was collected in 86 % of infants with bronchiolitis. In all patients clinical improvement at discharge was associated with disappearance of the previous LUS findings. Subpleural lung consolidation of 1 cm or more in the posterior area scan and a quantitative classification of interstitial syndrome based on intercostal spaces involved bilaterally, good correlate with bronchiolitis severity and oxygen use. Conclusions The lung ultrasound findings strictly correlate with the clinical evaluations in infants with bronchiolitis and permit the identification of infants who are in need of supplementary oxygen with high specificity. Scans of the posterior area are more indicative in ascertaining the severity of bronchiolitis. Trial registration Clinical Trial Registration NCT01993797
Collapse
|
24
|
Bishitz Y, Ozana N, Beiderman Y, Tenner F, Schmidt M, Mico V, Garcia J, Zalevsky Z. Noncontact optical sensor for bone fracture diagnostics. BIOMEDICAL OPTICS EXPRESS 2015; 6:651-7. [PMID: 25798293 PMCID: PMC4361423 DOI: 10.1364/boe.6.000651] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 11/13/2014] [Accepted: 12/18/2014] [Indexed: 05/20/2023]
Abstract
We present the first steps of a device suitable for detection of broken and cracked bones. The approach is based on temporal tracking of back reflected secondary speckle patterns generated when illuminating the limb with a laser and while applying periodic pressure stimulation via a loud speaker. Preliminary experiments are included showing the validity of the proposed device for detection of damaged bones.
Collapse
Affiliation(s)
- Yael Bishitz
- Faculty of Engineering, Bar-Ilan University, Ramat-Gan 52900,
Israel
- These authors contributed equally to the paper
| | - Nisan Ozana
- Faculty of Engineering, Bar-Ilan University, Ramat-Gan 52900,
Israel
- These authors contributed equally to the paper
| | - Yevgeny Beiderman
- Faculty of Engineering, Bar-Ilan University, Ramat-Gan 52900,
Israel
| | - Felix Tenner
- Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen,
Germany
- Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen,
Germany
| | - Michael Schmidt
- Institute of Photonic Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen,
Germany
- Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen,
Germany
| | | | | | - Zeev Zalevsky
- Faculty of Engineering, Bar-Ilan University, Ramat-Gan 52900,
Israel
- Graduate School in Advanced Optical Technologies, Friedrich-Alexander-Universität Erlangen-Nürnberg, 91052 Erlangen,
Germany
| |
Collapse
|
25
|
Tsai NW, Ngai CW, Mok KL, Tsung JW. Lung ultrasound imaging in avian influenza A (H7N9) respiratory failure. Crit Ultrasound J 2014; 6:6. [PMID: 24949191 PMCID: PMC4051407 DOI: 10.1186/2036-7902-6-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2014] [Accepted: 04/24/2014] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Lung ultrasound has been shown to identify in real-time, various pathologies of the lung such as pneumonia, viral pneumonia, and acute respiratory distress syndrome (ARDS). Lung ultrasound maybe a first-line alternative to chest X-ray and CT scan in critically ill patients with respiratory failure. We describe the use of lung ultrasound imaging and findings in two cases of severe respiratory failure from avian influenza A (H7N9) infection. METHODS Serial lung ultrasound images and video from two cases of H7N9 respiratory failure requiring mechanical ventilation and extracorporeal membrane oxygenation in a tertiary care intensive care unit were analyzed for characteristic lung ultrasound findings described previously for respiratory failure and infection. These findings were followed serially, correlated with clinical course and chest X-ray. RESULTS IN BOTH PATIENTS, CHARACTERISTIC LUNG ULTRASOUND FINDINGS HAVE BEEN OBSERVED AS PREVIOUSLY DESCRIBED IN VIRAL PULMONARY INFECTIONS: subpleural consolidations associated or not with local pleural effusion. In addition, numerous, confluent, or coalescing B-lines leading to 'white lung' with corresponding pleural line thickening are associated with ARDS. Extension or reduction of lesions observed with ultrasound was also correlated respectively with clinical worsening or improvement. Coexisting consolidated pneumonia with sonographic air bronchograms was noted in one patient who did not survive. CONCLUSIONS Clinicians with access to point-of-care ultrasonography may use these findings as an alternative to chest X-ray or CT scan. Lung ultrasound imaging may assist in the efficient allocation of intensive care for patients with respiratory failure from viral pulmonary infections, especially in resource scarce settings or situations such as future respiratory virus outbreaks or pandemics.
Collapse
Affiliation(s)
- Nga Wing Tsai
- Adult Intensive Care Unit, Queen Mary Hospital, 102 Pok Fu Lam Road, Hong Kong, SAR, China
| | - Chun Wai Ngai
- Adult Intensive Care Unit, Queen Mary Hospital, 102 Pok Fu Lam Road, Hong Kong, SAR, China
| | - Ka Leung Mok
- Accident and Emergency Department, Ruttonjee Hospital, 266 Queen’s Way, Wan Chai, Hong Kong, SAR, China
| | - James W Tsung
- Department of Emergency Medicine, Division of Emergency Ultrasound, Mount Sinai School of Medicine, New York, NY 10029, USA
| |
Collapse
|
26
|
Childhood and parental diagnostic radiological procedures and risk of childhood brain tumors. Cancer Causes Control 2014; 25:375-83. [DOI: 10.1007/s10552-014-0338-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2013] [Accepted: 01/08/2014] [Indexed: 11/27/2022]
|
27
|
Schüz J, Kaatsch P. Epidemiology of pediatric tumors of the central nervous system. Expert Rev Neurother 2014. [DOI: 10.1586/14737175.2.4.469] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
28
|
|
29
|
Caiulo VA, Gargani L, Caiulo S, Fisicaro A, Moramarco F, Latini G, Picano E, Mele G. The role of ultrasound in community-acquired pneumonia. Pediatr Pulmonol 2013; 48:1043-4. [PMID: 23401424 DOI: 10.1002/ppul.22787] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- V A Caiulo
- School of Ultrasound of Italian Federation of Pediatricians, Brindisi, Italy
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Baysson H, Réhel JL, Boudjemline Y, Petit J, Girodon B, Aubert B, Laurier D, Bonnet D, Bernier MO. Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France. BMC Public Health 2013; 13:266. [PMID: 23521893 PMCID: PMC3621730 DOI: 10.1186/1471-2458-13-266] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 03/08/2013] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Radiation can be used effectively for diagnosis and medical treatment, but it can also cause cancers later on. Children with congenital heart disease frequently undergo cardiac catheterization procedures for diagnostic or treatment purposes. Despite the clear clinical benefit to the patient, the complexity of these procedures may result in high cumulative radiation exposure. Given children's greater sensitivity to radiation and the longer life span during which radiation health effects can develop, an epidemiological cohort study is being launched in France to evaluate the risks of leukaemia and solid cancers in this specific population. METHODS/DESIGN The study population will include all children who have undergone at least one cardiac catheterization procedure since 2000 and were under 10 years old and permanent residents of France at the time of the procedure. Electronically stored patient records from the departments of paediatric cardiology of the French national network for complex congenital heart diseases (M3C) are being searched to identify the children to be included. The minimum dataset will comprise: identification of the subject (file number in the centre or department, full name, sex, date and place of birth), and characteristics of the intervention (date, underlying disease, type of procedure, technical details, such as fluoroscopy time and dose area product, (DAP), which are needed to reconstruct the doses received by each child). The cohort will be followed up through linkage with the two French paediatric cancer registries, which have recorded all cases of childhood leukaemia and solid cancers in France since 1990 and 2000, respectively. Radiation exposure will be estimated retrospectively for each child. 4500 children with catherizations between 2000 and 2011 have been already included in the cohort, and recruitment is ongoing at the national level. The study is expected to finally include a total of 8000 children. DISCUSSION This French cohort study is specifically designed to provide further knowledge about the potential cancer risks associated with paediatric cardiac catheterization procedures. It will also provide new information on typical dose levels associated with these procedures in France. Finally, it should help improve awareness of the importance of radiation protection in these procedures.
Collapse
Affiliation(s)
- Helene Baysson
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Jean Luc Réhel
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Younes Boudjemline
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Jerôme Petit
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Centre Chirurgical Marie Lannelongue, Le Plessis Robinson, France
| | - Brigitte Girodon
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Bernard Aubert
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Dominique Laurier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| | - Damien Bonnet
- Centre de Référence Malformations Cardiaques Congénitales Complexes, M3C, Hôpital Necker-Enfants malades, AP-HP, Université Paris Descartes, Sorbonne Paris Cité, Paris, France
| | - Marie-Odile Bernier
- Institut de Radioprotection et de Sûreté Nucléaire, PRP-HOM, SRBE, BP 17, Fontenay aux Roses, France
| |
Collapse
|
31
|
Abstract
AIM To evaluate the diagnostic possibilities of lung ultrasonography (LUS) in detecting pulmonary complications in preterm infants with respiratory distress syndrome (RDS). MATERIAL AND METHODS A prospective study included 120 preterm infants with clinical and radiographic signs of RDS. LUS was performed using both a transthoracic and a transabdominal approach within the first 24 h of life, and, after that, follow-up LUS examinations were performed. In 47 detected pulmonary complications of RDS (hemorrhage, pneumothorax, pneumonia, atelectasis, bronchopulmonary dysplasia), comparisons between LUS and chest X-ray (CXR) were made. Also, 90 subpleural consolidations registered during LUS examinations were analysed. Statistical analysis included MANOVA and discriminant analysis, t-test, confidence interval, and positive predictive value. RESULTS In 45 of 47 instances the same diagnosis of complication was detected with LUS as with CXR, indicating a high reliability of the method in premature infants with RDS. The only two false negative findings concerned partial pneumothorax. The positive predictive value of LUS was 100%. A statistically significant difference of LUS findings between the anterior and posterior lung areas was observed in both right and left hemithoraces. CONCLUSIONS LUS enables the detection of pulmonary complications in preterm infants with RDS and has the potential to reduce the number of CXRs. The specific guidelines for its use should be provided in a more extensive study.
Collapse
Affiliation(s)
- Jovan Lovrenski
- Department, Institute for Children and Adolescents Health Care of Vojvodina, Gogoljeva, Novi Sad, Serbia.
| |
Collapse
|
32
|
Linet MS, Slovis TL, Miller DL, Kleinerman R, Lee C, Rajaraman P, Berrington de Gonzalez A. Cancer risks associated with external radiation from diagnostic imaging procedures. CA Cancer J Clin 2012; 62:75-100. [PMID: 22307864 PMCID: PMC3548988 DOI: 10.3322/caac.21132] [Citation(s) in RCA: 220] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but increased potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate the widespread use of evidence-based appropriateness criteria for decisions about imaging procedures; oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives; development of electronic lifetime records of imaging procedures for patients and their physicians; and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures.
Collapse
Affiliation(s)
- Martha S Linet
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD 20892-7238, USA.
| | - Thomas L Slovis
- Chief, Pediatric Radiology, Department of Radiology, Children's Hospital of Michigan, Detroit, MI
| | - Donald L Miller
- Acting Chief, Diagnostic Devices Branch, Division of Mammography Quality and Radiation Program Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD
| | - Ruth Kleinerman
- Epidemiologist, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD
| | - Choonsik Lee
- Investigator, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD
| | - Preetha Rajaraman
- Investigator, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD
| | - Amy Berrington de Gonzalez
- Senior Investigator, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD
| |
Collapse
|
33
|
Baysson H, Etard C, Brisse HJ, Bernier MO. [Diagnostic radiation exposure in children and cancer risk: current knowledge and perspectives]. Arch Pediatr 2011; 19:64-73. [PMID: 22130615 DOI: 10.1016/j.arcped.2011.10.023] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2011] [Revised: 08/30/2011] [Accepted: 10/21/2011] [Indexed: 10/14/2022]
Abstract
The question of the risk of cancer associated with postnatal diagnostic medical exposure involving ionizing radiation in childhood is particularly relevant at the moment given the growing use of diagnostic examinations, especially computed tomography scans, in children. Compared to adults, pediatric patients are more sensitive to radiation and have more years of life expectancy and therefore more years at risk of cancer occurrence as compared to adults. This paper provides a description of diagnostic x-ray exposure in children in France and summarizes epidemiologic studies on subsequent risk of cancer. Overall, this review, based on 12 case-control studies and 6 cohort studies, shows no significant association between exposure to medical diagnostic radiation exposure and childhood cancer risk. The methodological limitations of these studies are discussed. As the expected cancer risks are low, epidemiological studies require very large sample sizes and long periods of follow-up in addition to a good dosimetry assessment to enable quantitative risk estimation. New cohort studies of young patients who underwent CT scans are currently underway within the European EPI-CT project. In the meantime, continued efforts to reduce doses and the number of radiological examinations in children are needed, including adhering to the "as long as reasonably achievable" (Alara) principle.
Collapse
Affiliation(s)
- H Baysson
- IRSN, DRPH, SER, laboratoire d'épidémiologie, BP17, 92262 Fontenay-aux-Roses cedex, France.
| | | | | | | |
Collapse
|
34
|
Lung ultrasound in bronchiolitis: comparison with chest X-ray. Eur J Pediatr 2011; 170:1427-33. [PMID: 21468639 DOI: 10.1007/s00431-011-1461-2] [Citation(s) in RCA: 112] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2011] [Accepted: 03/22/2011] [Indexed: 01/21/2023]
Abstract
The diagnosis of bronchiolitis is based mainly on the patient's medical history and physical examination. However, in severe cases, a further evaluation including chest X-ray (CXR) may be necessary. At present, lung ultrasound (LUS) is not included in the diagnostic work-up of bronchiolitis. This study aimed to compare the diagnostic accuracy of LUS and CXR in children with bronchiolitis, and to evaluate the correlation between clinical and ultrasound findings. Only patients with a diagnosis of bronchiolitis, who had undergone a CXR, were enrolled in the study. Fifty-two infants underwent LUS and CXR. LUS was also performed in 52 infants without clinical signs of bronchiolitis. LUS was positive for the diagnosis of bronchiolitis in 47/52 patients, whereas CXR was positive in 38/52. All patients with normal LUS examination had a normal CXR, whereas nine patients with normal CXR had abnormal LUS. In these patients, the clinical course was consistent with bronchiolitis. We found that LUS is a simple and reliable tool for the diagnosis and follow-up of bronchiolitis. It is more reliable than CXR, can be easily repeated at the patient's bedside, and carries no risk of irradiation. In some patients with bronchiolitis, LUS is able to identify lung abnormalities not revealed by CXR. Furthermore, there is a good correlation between clinical and ultrasound findings. Given the short time needed to get a US report, this technique could become the routine imaging modality for patients with bronchiolitis.
Collapse
|
35
|
Childhood cancer risk from conventional radiographic examinations for selected referral criteria: results from a large cohort study. AJR Am J Roentgenol 2011; 197:217-23. [PMID: 21701033 DOI: 10.2214/ajr.10.4979] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Little is known about the long-term effects of exposure to diagnostic ionizing radiation in childhood. Current estimates are made with models derived mainly from studies of atomic bomb survivors, a population that differs from today's patients in many respects. MATERIALS AND METHODS We analyzed the cancer incidence among children who underwent diagnostic x-ray exposures between 1976 and 2003 in a large German university hospital. We reconstructed individual radiation doses for each examination and sorted results by groups of referral criteria for all cancers combined, solid tumors, and leukemia and lymphoma combined. RESULTS A total of 68 incidence cancer cases between 1980 and 2006 were identified in a 78,527-patient cohort in the German childhood cancer registry: 28 leukemia, nine lymphoma, six tumors of the CNS, and 25 other tumors. The standardized incidence ratio for all cancers was 0.97 (95% CI, 0.75-1.23). Dose-response relations were analyzed by multivariable Poisson regression. Although the cancer incidence risk differed by initial referral criterion for radiographic examination, a positive dose-response relation was observed in five patients with endocrine or metabolic disease. CONCLUSION Overall, we observed no increase in cancer risk among children and youths with very low radiation doses from diagnostic radiation, which is compatible with model calculations. The growing use of CT warrants further studies to assess associated cancer risk. Our work is an early contribution of epidemiologic data for quantifying these risks among young patients.
Collapse
|
36
|
Ter Haar G. Ultrasonic imaging: safety considerations. Interface Focus 2011; 1:686-97. [PMID: 22866238 DOI: 10.1098/rsfs.2011.0029] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Accepted: 05/03/2011] [Indexed: 11/12/2022] Open
Abstract
Modern ultrasound imaging for diagnostic purposes has a wide range of applications. It is used in obstetrics to monitor the progress of pregnancy, in oncology to visualize tumours and their response to treatment, and, in cardiology, contrast-enhanced studies are used to investigate heart function and physiology. An increasing use of diagnostic ultrasound is to provide the first photograph for baby's album-in the form of a souvenir or keepsake scan that might be taken as part of a routine investigation, or during a visit to an independent high-street 'boutique'. It is therefore important to ensure that any benefit accrued from these applications outweighs any accompanying risk, and to evaluate the existing ultrasound bio-effect and epidemiology literature with this in mind. This review considers the existing laboratory and epidemiological evidence about the safety of diagnostic ultrasound and puts it in the context of current clinical usage.
Collapse
Affiliation(s)
- Gail Ter Haar
- Joint Department of Physics , Institute of Cancer Research, Royal Marsden Hospital , Sutton SM2 5PT , UK
| |
Collapse
|
37
|
Rajaraman P, Simpson J, Neta G, Berrington de Gonzalez A, Ansell P, Linet MS, Ron E, Roman E. Early life exposure to diagnostic radiation and ultrasound scans and risk of childhood cancer: case-control study. BMJ 2011; 342:d472. [PMID: 21310791 PMCID: PMC3037470 DOI: 10.1136/bmj.d472] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
OBJECTIVE To examine childhood cancer risks associated with exposure to diagnostic radiation and ultrasound scans in utero and in early infancy (age 0-100 days). DESIGN Case-control study. SETTING England and Wales. PARTICIPANTS 2690 childhood cancer cases and 4858 age, sex, and region matched controls from the United Kingdom Childhood Cancer Study (UKCCS), born 1976-96. MAIN OUTCOME MEASURES Risk of all childhood cancer, leukaemia, lymphoma, and central nervous system tumours, measured by odds ratios. RESULTS Logistic regression models conditioned on matching factors, with adjustment for maternal age and child's birth weight, showed no evidence of increased risk of childhood cancer with in utero exposure to ultrasound scans. Some indication existed of a slight increase in risk after in utero exposure to x rays for all cancers (odds ratio 1.l4, 95% confidence interval 0.90 to 1.45) and leukaemia (1.36, 0.91 to 2.02), but this was not statistically significant. Exposure to diagnostic x rays in early infancy (0-100 days) was associated with small, non-significant excess risks for all cancers and leukaemia, as well as increased risk of lymphoma (odds ratio 5.14, 1.27 to 20.78) on the basis of small numbers. CONCLUSIONS Although the results for lymphoma need to be replicated, all of the findings indicate possible risks of cancer from radiation at doses lower than those associated with commonly used procedures such as computed tomography scans, suggesting the need for cautious use of diagnostic radiation imaging procedures to the abdomen/pelvis of the mother during pregnancy and in children at very young ages.
Collapse
Affiliation(s)
- Preetha Rajaraman
- Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, MD 20892-7238, USA.
| | | | | | | | | | | | | | | |
Collapse
|
38
|
Bailey HD, Armstrong BK, de Klerk NH, Fritschi L, Attia J, Lockwood L, Milne E. Exposure to Diagnostic Radiological Procedures and the Risk of Childhood Acute Lymphoblastic Leukemia. Cancer Epidemiol Biomarkers Prev 2010; 19:2897-909. [DOI: 10.1158/1055-9965.epi-10-0542] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
39
|
Chong AL, Grant RM, Ahmed BA, Thomas KE, Connolly BL, Greenberg M. Imaging in pediatric patients: time to think again about surveillance. Pediatr Blood Cancer 2010; 55:407-13. [PMID: 20658609 DOI: 10.1002/pbc.22575] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Despite concerns regarding ionizing radiation exposures from diagnostic imaging procedures in pediatric patients, many are deemed unavoidable or even mandated by treatment protocols. A prior review at our institution found patients with lymphoma had a higher median cumulative radiation exposure (191 mSv) versus other oncology subgroups (61 mSv). PURPOSE Estimations of cumulative diagnostic radiation exposures were tabulated for 5 years from the first diagnostic scan for 30 consecutive lymphoma patients diagnosed in 2001. Each individual imaging procedure was reviewed and classified as protocol mandated or discretionary (for disease surveillance, good patient care or radiologist request). RESULTS Almost all patients (28/29) received chemotherapy; one had surgery only. Individual cumulative radiation exposures ranged from 10 to 642 mSv. Over 5 years, 690 procedures were performed; 303 (44%) X-rays, 203 (29%) CTs, 157 (23%) radionucleotide, and 27 (4%) interventional procedures. Of these, 238 (34%) were protocol required and 452 (66%) discretionary (224 as part of good patient care for a co-morbid illness and 228 for evaluation of possible disease progression/surveillance). A total of 86/217 (40%) studies (including 43 CTs and 38 radionucleotide scans) were performed when the recurrence risk was low (>2 years off therapy). CONCLUSIONS The majority of ionizing radiation procedures in this lymphoma cohort were discretionary. Given the excellent outcome of this group and the long-term risks; rational use of discretionary surveillance procedures is necessary. Guidelines for the appropriate use of surveillance imaging based on probability of risk recurrence must be developed in order to minimize ionizing radiation exposure.
Collapse
Affiliation(s)
- Amy Lee Chong
- Division of Haematology/Oncology, Department of Pediatrics, The Hospital for Sick Children, Toronto, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
40
|
Practice management guidelines for the diagnosis and management of injury in the pregnant patient: the EAST Practice Management Guidelines Work Group. ACTA ACUST UNITED AC 2010; 69:211-4. [PMID: 20622592 DOI: 10.1097/ta.0b013e3181dbe1ea] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Trauma during pregnancy has presented very unique challenges over the centuries. From the first report of Ambrose Pare of a gunshot wound to the uterus in the 1600s to the present, there have existed controversies and inconsistencies in diagnosis, management, prognostics, and outcome. Anxiety is heightened by the addition of another, smaller patient. Trauma affects 7% of all pregnancies and requires admission in 4 of 1000 pregnancies. The incidence increases with advancing gestational age. Just over half of trauma during pregnancy occurs in the third trimester. Motor vehicle crashes comprise 50% of these traumas, and falls and assaults account for 22% each. These data were considered to be underestimates because many injured pregnant patients are not seen at trauma centers. Trauma during pregnancy is the leading cause of nonobstetric death and has an overall 6% to 7% maternal mortality. Fetal mortality has been quoted as high as 61% in major trauma and 80% if maternal shock is present. The anatomy and physiology of pregnancy make diagnosis and treatment difficult.
Collapse
|
41
|
Bao PP, Zheng Y, Gu K, Wang CF, Wu CX, Jin F, Lu W. Trends in childhood cancer incidence and mortality in urban Shanghai, 1973-2005. Pediatr Blood Cancer 2010; 54:1009-13. [PMID: 20052777 DOI: 10.1002/pbc.22383] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND To describe trends in cancer incidence and mortality among children less than 15 years of age in urban Shanghai between 1973 and 2005. PROCEDURE Annual rates of cancer incidence were calculated per 1,000,000 children for 3-year intervals between 1973 and 2005. Linear regression models were used to analyze the annual percent change (APC) in incidence and mortality across these distinct intervals. RESULTS For all cancers combined, the incidence rate during the observed time period did not substantially change in urban Shanghai. Rates for the incidence of individual cancer did exhibit variations. Leukemia incidence remained relatively stable but the incidence of myeloid leukemia decreased sharply in both males (APC -8.6%) and females (APC -9.5%). The rate of NHL varied little among males with APC 2.1% and modestly increased among females with APC 9.3%. Anatomic sites that only occasionally demonstrate malignancy, bone and joints in males and endocrines in females, showed upward trends in incidence. A significant reduction in liver cancer incidence in males was observed. Examining mortality rates, all cancer mortality decreased by -6.0% annually in males and by -3.9% in females. This trend was mainly due to the reduction in mortality for leukemia, particularly the myeloid subtype, which decreased in males (APC -7.2%) and females (APC -7.3%). CONCLUSIONS Childhood cancer incidence rates showed no substantial changes but mortality demonstrated a dramatic reduction during the observed time period, suggesting an improvement in both childhood cancer diagnosis and treatment.
Collapse
Affiliation(s)
- Ping-ping Bao
- Shanghai Cancer Registry, Department of Cancer Control and Prevention, Shanghai Municipal Center for Disease Prevention and Control, 1380 Zhongshan Road West, Shanghai 200336, China
| | | | | | | | | | | | | |
Collapse
|
42
|
Houston LE, Odibo AO, Macones GA. The safety of obstetrical ultrasound: a review. Prenat Diagn 2009; 29:1204-12. [DOI: 10.1002/pd.2392] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
43
|
Chodick G, Kim KP, Shwarz M, Horev G, Shalev V, Ron E. Radiation risks from pediatric computed tomography scanning. PEDIATRIC ENDOCRINOLOGY REVIEWS : PER 2009; 7:29-36. [PMID: 20118891 PMCID: PMC6298033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Although radiological exams are not frequently used to diagnose unsuspected endocrine disease, computed tomography (CT) plays a significant role in today's endocrinology. Despite the known association between radiation exposure during childhood and cancer, the use of pediatric CT, which delivers non-negligible radiation doses to some organs and tissues, continues to rise sharply. The purpose of this review is to describe the current use of pediatric CT, explain basic concepts in ionizing radiation physics and dosimetry, and discuss potential risks from pediatric CT scans. Finally, we will summarize two recent programs for reducing and controlling exposure to ionizing radiation from pediatric CT: the As Low As Reasonably Achievable (ALARA) concept and the Image Gently initiative. Promoting public awareness and particularly educating referring physicians, including endocrinologists, about the potential radiation-associated risks from CT scans, is essential for reducing unnecessary radiation exposure from CT in children.
Collapse
Affiliation(s)
- Gabriel Chodick
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, MD, USA
- Medicallnformatics, Maccabi Healthcare Services, Tel-Aviv, Israel
| | - Kwang Pyo Kim
- Department of Nuclear Engineering, Kyung Hee University, Republic of Korea
| | - Michael Shwarz
- Pediatric Radiology Dept. Schneider Children‘s Medical Center of Israel, Petach-Tiqva, Israel
| | - Gad Horev
- Pediatric Radiology Dept. Schneider Children‘s Medical Center of Israel, Petach-Tiqva, Israel
| | - Varda Shalev
- Medicallnformatics, Maccabi Healthcare Services, Tel-Aviv, Israel
| | - Elaine Ron
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, NIH, DHHS, Bethesda, MD, USA
| |
Collapse
|
44
|
Shrotri KN, Morrison ID, Shrotri NC. Urological conditions in pregnancy: A diagnostic and therapeutic challenge. J OBSTET GYNAECOL 2009; 27:648-54. [DOI: 10.1080/01443610701582834] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
45
|
Bao PP, Zheng Y, Wang CF, Gu K, Jin F, Lu W. Time trends and characteristics of childhood cancer among children age 0-14 in Shanghai. Pediatr Blood Cancer 2009; 53:13-6. [PMID: 19260104 DOI: 10.1002/pbc.21939] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The aim of this article is to analyze the time trends during 1973-2005 in urban Shanghai and to describe the current characteristics of childhood cancer in Shanghai. PROCEDURE All data were from the Shanghai Cancer Registry. Time trends of period 1973-2005 in urban Shanghai of males and females were assessed by annual percentage change of incidence. The current characteristics of Shanghai childhood cancer average annual incidence were analyzed regarding sex, age, and cancer types. All cancers were allocated into 12 major groupings of ICCC. RESULTS Over the 33-year period, the overall age-standardized incidence rate for all cancers combined has no substantial change or trend in urban Shanghai aged 0-14. A total of 609 cases of childhood cancer were diagnosed in Shanghai from 2002 to 2005. The ASR of 2002-2005 is 129.0 per million for all cancers combined, and it was almost similar in males (128.5 per million) and in females (129.6 per million). Incidence rates are highest in the first 5 years of life with 173.3 per million. Leukaemia was the most common cancer (34.5%). Brain and spinal tumour was the second most common cancer (20.2%), followed by lymphomas (8.4%). The relative frequencies of Wilms tumour (2.0%) and Ewing sarcoma (0.5%) were lower than those reported from western countries. CONCLUSION During 1973-2005, the trend of childhood cancer incidence in urban Shanghai has shown no significant change. Incidence of childhood cancers in Shanghai was in the medium level compared to other parts of the world and the relative frequencies of various cancers were comparable.
Collapse
Affiliation(s)
- Ping-Ping Bao
- Shanghai Cancer Registry, Department of Cancer Control & Prevention, Shanghai Municipal Center for Disease Prevention & Control, Shanghai, China
| | | | | | | | | | | |
Collapse
|
46
|
Buffler PA, Kwan ML, Reynolds P, Urayama KY. Environmental and Genetic Risk Factors for Childhood Leukemia: Appraising the Evidence. Cancer Invest 2009. [DOI: 10.1081/cnv-46402] [Citation(s) in RCA: 150] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
47
|
Hammer GP, Seidenbusch MC, Schneider K, Regulla DF, Zeeb H, Spix C, Blettner M. A cohort study of childhood cancer incidence after postnatal diagnostic X-ray exposure. Radiat Res 2009; 171:504-12. [PMID: 19397451 DOI: 10.1667/rr1575.1] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Ionizing radiation is an established cause of cancer, yet little is known about the health effects of doses from diagnostic examinations in children. The risk of childhood cancer was studied in a cohort of 92.957 children who had been examined with diagnostic X rays in a large German hospital during 1976-2003. Radiation doses were reconstructed using the individual dose area product and other exposure parameters, together with conversion coefficients developed specifically for the medical devices and standards used at the radiology department. Newly diagnosed cancers occurring between 1980 and 2006 were determined through record linkage to the German Childhood Cancer Registry. The median radiation dose was 7 microSv. Eight-seven incident cases were found in the cohort: 33 leukemia, 13 lymphoma, 10 central nervous system tumors, and 31 other tumors. The standardized incidence ratio (SIR) for all cancers was 0.99 (95% CI: 0.79-1.22). No trend in the incidence of total cancer, leukemia or solid tumors with increasing radiation dose was observed in the SIR analysis or in the multivariate Poisson regression. Risk did not differ significantly in girls and boys. Overall, while no increase in cancer risk with diagnostic radiation was observed, the results are compatible with a broad range of risk estimates.
Collapse
Affiliation(s)
- Gaël P Hammer
- Institute for Medical Biostatistics, Epidemiology and Informatics (IMBEI), Johannes Gutenberg-University, Mainz, Germany.
| | | | | | | | | | | | | |
Collapse
|
48
|
Torloni MR, Vedmedovska N, Merialdi M, Betrán AP, Allen T, González R, Platt LD. Safety of ultrasonography in pregnancy: WHO systematic review of the literature and meta-analysis. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 33:599-608. [PMID: 19291813 DOI: 10.1002/uog.6328] [Citation(s) in RCA: 104] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
OBJECTIVE In the context of the planned International Society of Ultrasound in Obstetrics and Gynecology-World Health Organization multicenter study for the development of fetal growth standards for international application, we conducted a systematic review and meta-analysis to evaluate the safety of human exposure to ultrasonography in pregnancy. METHODS A systematic search of electronic databases, reference lists and unpublished literature was conducted for trials and observational studies that assessed short- and long-term effects of exposure to ultrasonography, involving women and their fetuses exposed to ultrasonography, using B-mode or Doppler sonography during any period of pregnancy, for any number of times. The outcome measures were: (1) adverse maternal outcome; (2) adverse perinatal outcome; (3) abnormal childhood growth and neurological development; (4) non-right handedness; (5) childhood malignancy; and (6) intellectual performance and mental disease. RESULTS The electronic search identified 6716 citations, and 19 were identified from secondary sources. A total of 61 publications reporting data from 41 different studies were included: 16 controlled trials, 13 cohort and 12 case-control studies. Ultrasonography in pregnancy was not associated with adverse maternal or perinatal outcome, impaired physical or neurological development, increased risk for malignancy in childhood, subnormal intellectual performance or mental diseases. According to the available clinical trials, there was a weak association between exposure to ultrasonography and non-right handedness in boys (odds ratio 1.26; 95% CI, 1.03-1.54). CONCLUSION According to the available evidence, exposure to diagnostic ultrasonography during pregnancy appears to be safe.
Collapse
Affiliation(s)
- M R Torloni
- Department of Obstetrics, São Paulo Federal University and Brazilian Cochrane Center, São Paulo, Brazil.
| | | | | | | | | | | | | |
Collapse
|
49
|
Wakeford R. On pre- or postnatal diagnostic X-rays as a risk factor for childhood leukaemia. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2009; 48:237-241. [PMID: 19242714 DOI: 10.1007/s00411-009-0214-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2008] [Accepted: 02/07/2009] [Indexed: 05/27/2023]
|
50
|
Butler ML, Brennan PC. Nonselective Filters Offer Important Dose-Reducing Potential in Radiological Examination of the Paediatric Pelvis. J Med Imaging Radiat Sci 2009; 40:15-23. [DOI: 10.1016/j.jmir.2008.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2008] [Revised: 11/18/2008] [Accepted: 11/19/2008] [Indexed: 11/29/2022]
|