1
|
Jiang X, Yan S, Sun H, Kong XZ, Li S, Shi H, Zhu X, Gu X. Preparation of fluorescent polyurethane microspheres and their applications as reusable sensor for 4-nitrophenol detection and as microplastics model for visualizing polyurethane in cells and zebrafish. J Colloid Interface Sci 2024; 673:550-563. [PMID: 38889546 DOI: 10.1016/j.jcis.2024.06.070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/20/2024]
Abstract
Fluorescent microspheres are of significant interests due to their wide applications in biotechnology fields. However, their preparation presents several challenges, such as the need for dye labeling, the complexity of materials and often sophisticated preparation conditions. Here a simple process for hydrophilic and crosslinked polyurethane (CPU) microspheres, with carboxyl groups on the surface via one-step precipitation polymerization in 40 min, is presented. The microsphere size is easily adjusted by varying experimental conditions. CPU microspheres exhibit high thermal and pH stability with good redispersibility in water, and emit fluorescence without any modification or dye labeling. The emission mechanism is discussed. CPU microspheres are used as fluorescent probe to detect 4-nitrophenol (4-NP) based on their emission in UV light region, with excellent selectivity and sensitivity. In addition, they are reusable with detection limit unchanged after 7 cycles of reuses, a significant feature of this work. The mechanism of fluorescence detection is thoroughly explored and ascribed to the internal filtration effect. Based on the emission in visible light region, CPU microspheres are used as a model of PU microplastics (MPs) to visualize their biodistribution in HeLa and macrophage cells, as well as in zebrafish larvae, providing a reliable tracer for the visualization and tracking of PU MPs in organisms.
Collapse
Affiliation(s)
- Xubao Jiang
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Siqiang Yan
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Hao Sun
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Xiang Zheng Kong
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Shusheng Li
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Haoran Shi
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China
| | - Xiaoli Zhu
- College of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, China.
| | - Xiangling Gu
- Shandong Provincial Engineering Research Center of Novel Pharmaceutical Excipients and Controlled Release Preparations, College of Medicine and Nursing, Dezhou University, Dezhou 253023, China.
| |
Collapse
|
2
|
Sha Z, Ling T, Yang W, Xie H, Wang C, Sun S. Microfluidic synthesis and accurate immobilization of low-density QD-encoded magnetic microbeads for multiplex immunoassay. J Mater Chem B 2024. [PMID: 39373123 DOI: 10.1039/d4tb01585a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/08/2024]
Abstract
Magnetic-fluorescent microbeads have been widely used in the multiplex detection of biological molecules. The traditional method relies on flow cytometry to decode and analyze the microbeads. Alternative strategies that employ immobilized microbeads on a plane and involve fluorescence imaging to analyze the microbeads have been proposed. Among these strategies, an integrated chip that controls magnetic field contribution using nickel powder pillars and captured microbeads has attracted great attention. Despite its unique advantages such as low manufacturing costs, reusability and high capture efficiency, existing research had been limited by the inability to precisely capture a single microbead, and the overlapping of microbeads has made multiplex immunoassays based on this strategy impossible. In this work, low-density microbeads were prepared in a microfluidic chip using IBOMA as the main monomer. The low density of the microbeads made the preparation of an aqueous suspension easier. An integration of nickel patterns, magnets and channels was carried out and demonstrated the capacity of capturing single microbeads precisely. Fluorescence coding further empowered this method with the ability of multiplex immunoassay, which was verified using three types of IgG, and a calibration curve for the detection of anti-human IgG was established using a sandwich immunoassay. These results show the promising potential of this strategy for biomedical detection.
Collapse
Affiliation(s)
- Zhou Sha
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| | - Tianyi Ling
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| | - Wenqi Yang
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| | - Haosu Xie
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| | - Chunnan Wang
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| | - Shuqing Sun
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| |
Collapse
|
3
|
Zhang J, Zheng T, Helalat SH, Yesibolati MN, Sun Y. Synthesis of eco-friendly multifunctional dextran microbeads for multiplexed assays. J Colloid Interface Sci 2024; 666:603-614. [PMID: 38613982 DOI: 10.1016/j.jcis.2024.04.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Revised: 04/05/2024] [Accepted: 04/08/2024] [Indexed: 04/15/2024]
Abstract
There has been an increasing demand for simultaneous detection of multiple analytes in one sample. Microbead-based platforms have been developed for multiplexed assays. However, most of the microbeads are made of non-biodegradable synthetic polymers, leading to environmental and human health concerns. In this study, we developed an environmentally friendly dextran microbeads as a new type of multi-analyte assay platform. Biodegradable dextran was utilized as the primary material. Highly uniform magnetic dextran microspheres were successfully synthesized using the Shirasu porous glass (SPG) membrane emulsification technique. To enhance the amount of surface functional groups for ligand conjugation, we coated the dextran microbeads with a layer of dendrimers via a simple electrostatic adsorption process. Subsequently, a unique and efficient click chemistry coupling technique was developed for the fluorescence encoding of the microspheres, enabling multiplexed detection. The dextran microbeads were tested for 3-plex cytokine analysis, and exhibited excellent biocompatibility, stable coding signals, low background noise and high sensitivity.
Collapse
Affiliation(s)
- Jing Zhang
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800 Kgs. Lyngby, Denmark
| | - Tao Zheng
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800 Kgs. Lyngby, Denmark.
| | - Seyed Hossein Helalat
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800 Kgs. Lyngby, Denmark
| | - Murat Nulati Yesibolati
- National Centre for Nanofabrication and Characterization, Technical University of Denmark, Ørsteds Plads, DK-2800 Kgs. Lyngby, Denmark
| | - Yi Sun
- Department of Health Technology, Technical University of Denmark, Ørsteds Plads, DK-2800 Kgs. Lyngby, Denmark.
| |
Collapse
|
4
|
Chen Z, Luo G, Ren J, Wang Q, Zhao X, Wei L, Wang Y, Liu Y, Deng Y, Li S. Recent Advances in and Application of Fluorescent Microspheres for Multiple Nucleic Acid Detection. BIOSENSORS 2024; 14:265. [PMID: 38920569 PMCID: PMC11201543 DOI: 10.3390/bios14060265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 05/17/2024] [Accepted: 05/21/2024] [Indexed: 06/27/2024]
Abstract
Traditional single nucleic acid assays can only detect one target while multiple nucleic acid assays can detect multiple targets simultaneously, providing comprehensive and accurate information. Fluorescent microspheres in multiplexed nucleic acid detection offer high sensitivity, specificity, multiplexing, flexibility, and scalability advantages, enabling precise, real-time results and supporting clinical diagnosis and research. However, multiplexed assays face challenges like complexity, costs, and sample handling issues. The review explores the recent advancements and applications of fluorescent microspheres in multiple nucleic acid detection. It discusses the versatility of fluorescent microspheres in various fields, such as disease diagnosis, drug screening, and personalized medicine. The review highlights the possibility of adjusting the performance of fluorescent microspheres by modifying concentrations and carrier forms, allowing for tailored applications. It emphasizes the potential of fluorescent microsphere technology in revolutionizing nucleic acid detection and advancing health, disease treatment, and medical research.
Collapse
Affiliation(s)
- Zhu Chen
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
| | - Gaoming Luo
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
- Hunan Province Key Laboratory of Tumor Cellular & Molecular Pathology, Hunan Engineering Research Center for Early Diagnosis and Treatment of Liver Cancer, Cancer Research Institute, Hengyang Medical School, University of South China, Hengyang 421001, China
| | - Jie Ren
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
| | - Qixuan Wang
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
- Hunan Province Key Laboratory of Tumor Cellular & Molecular Pathology, Hunan Engineering Research Center for Early Diagnosis and Treatment of Liver Cancer, Cancer Research Institute, Hengyang Medical School, University of South China, Hengyang 421001, China
| | - Xinping Zhao
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang 421001, China
| | - Linyu Wei
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
- Institute of Cytology and Genetics, School of Basic Medical Sciences, Hengyang Medical School, University of South China, Hengyang 421001, China
| | - Yue Wang
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, Hunan University of Technology, Zhuzhou 412007, China;
| | - Yuan Liu
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
| | - Yan Deng
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
| | - Song Li
- MOE Key Lab of Rare Pediatric Diseases & Hengyang Medical School, University of South China, Hengyang 421001, China; (G.L.); (J.R.); (Q.W.); (X.Z.); (L.W.); (Y.L.); (Y.D.)
- Institute for Future Sciences, University of South China, Changsha 410008, China
| |
Collapse
|
5
|
Zhao X, Xu Y, Chen Z, Tang C, Mi X. Encoding fluorescence intensity with tetrahedron DNA nanostructure based FRET effect for bio-detection. Biosens Bioelectron 2024; 248:115994. [PMID: 38181517 DOI: 10.1016/j.bios.2023.115994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 12/20/2023] [Accepted: 12/29/2023] [Indexed: 01/07/2024]
Abstract
Biocoding technology constructed by readable tags with distinct signatures is a brand-new bioanalysis method to realize multiplexed identification and bio-information decoding. In this study, a novel fluorescence intensity coding technology termed Tetra-FICT was reported based on tetrahedron DNA nanostructure (TDN) carrier and Főrster Resonance Energy Transfer (FRET) effect. By modulating numbers and distances of Cy3 and Cy5 at four vertexes of TDN, different fluorescence intensities of twenty-six samples were produced at ∼565.0 nm (FICy3) and ∼665.0 nm (FICy5) by detecting fluorescence spectra. By developing an error correction mechanism, eleven codes were established based on divided intensity ranges of the final FICy3 together with FICy5 (Final-FICy3&FICy5). These resulting codes were used to construct barcode probes, with three miRNA biomarkers (miRNA-210, miRNA-199a and miRNA-21) as cases for multiplexed bio-assay. The high specificity and sensitivity were also demonstrated for the detection of miRNA-210. Overall, the proposed Tetra-FICT enriched the toolbox of fluorescence coding, which could be applied to multiplexing biomarkers detection.
Collapse
Affiliation(s)
- Xiaoshuang Zhao
- National Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai, 200050, China; School of Physics and Optoelectronic Engineering, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China; University of Chinese Academy of Science, Beijing, 100049, China
| | - Yi Xu
- National Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai, 200050, China; Shanghai Advanced Research Institute, Chinese Academy of Science, Shanghai, 201210, China
| | - Ziting Chen
- National Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai, 200050, China; University of Chinese Academy of Science, Beijing, 100049, China
| | - Chengren Tang
- National Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai, 200050, China; University of Chinese Academy of Science, Beijing, 100049, China
| | - Xianqiang Mi
- National Key Laboratory of Materials for Integrated Circuits, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, 865 Changning Road, Shanghai, 200050, China; Shanghai Advanced Research Institute, Chinese Academy of Science, Shanghai, 201210, China; School of Physics and Optoelectronic Engineering, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, 310024, China; University of Chinese Academy of Science, Beijing, 100049, China.
| |
Collapse
|
6
|
Gu T, Zhong J, Ge M, Shi R, He L, Bai P. Water-stable perovskite-silica nanocomposites for encoded microbeads construction and multiplexed detection. J Colloid Interface Sci 2024; 657:580-589. [PMID: 38071807 DOI: 10.1016/j.jcis.2023.11.185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 11/16/2023] [Accepted: 11/30/2023] [Indexed: 01/02/2024]
Abstract
All-inorganic lead halide perovskite nanocrystals exhibiting bright luminescence have great potential as fluorescence elements for optical encoding. However, their limited stability in water hinders the application in biosensing. In this study, novel optical encoded microbeads based on CsPbX3 (X = Cl, Br) nanocrystals are developed and applied in bead-based suspension arrays for the first time. Through the in-situ crystallization of CsPbX3 nanocrystals within mesoporous silica nano-templates (MSNs), accompanied by mesopores collapse after sintering, CsPbX3@MSNs (X3M) nanocomposites with uniform morphology and stable fluorescence intensity in aqueous solutions for up to 50 days are obtained. By assembling X3M with microspheres to form a host-guest structure, an optical encoding microbead (MX3M) library is established by varying the X3M ratio, halide composition, and the size of host microspheres, which can be easily decoded under multi-channel flow cytometer. As a result, MX3M exhibits outstanding capacity for specific target capture and negligible nonspecific absorption performance in the multiplex nucleic acid detection of respiratory viruses, with a low limit of detection (10 copies/rxn). This result highlights the tremendous potential of MX3M encoded microbeads constructed based on CsPbX3 nanocrystals for multiplexed bioassays.
Collapse
Affiliation(s)
- Tongxu Gu
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China.
| | - Jiajun Zhong
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China
| | - Minghao Ge
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China
| | - Ruiju Shi
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China
| | - Liang He
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China; CAS Key Lab of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, People's Republic of China
| | - Pengli Bai
- Jihua Laboratory, No.28 Island Ring South Road, Guicheng Street, Nanhai District, Foshan, Guangdong 528200, People's Republic of China; CAS Key Lab of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, People's Republic of China.
| |
Collapse
|
7
|
Yu D, Zhu W, Shen AG. Raman encoding for security labels: a review. NANOSCALE ADVANCES 2023; 5:6365-6381. [PMID: 38024325 PMCID: PMC10662010 DOI: 10.1039/d3na00707c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Accepted: 10/18/2023] [Indexed: 12/01/2023]
Abstract
Owing to its excellent multiplexing ability, high stability, and molecular fingerprint characteristics, Raman encoding has been widely used in security labels for medical safety, jewelry identification and food supervision. Various growing demands have promoted the anti-counterfeiting mode of security labels based on Raman encoding from the classic one that relies on specific patterns to the more secure one that depends on random patterns. As impressive progress has been made in Raman encoding for security labels in recent years, this review attempts to comprehensively cover security labels based on Raman encoding, from label preparation to image verification. For the labels with different anti-counterfeiting modes, the different basic elements they need are summarized, and the role of Raman encoding in different modes is introduced. In addition, security labels based on Raman encoding still have some drawbacks. Therefore, suggestions on how to improve its anti-counterfeiting performance are also discussed, as well as future challenges and prospects.
Collapse
Affiliation(s)
- Dong Yu
- School of Bioengineering and Health, Wuhan Textile University Wuhan 430220 China
- College of Chemistry and Molecular Sciences, Wuhan University Wuhan 430072 China
| | - Wei Zhu
- School of Bioengineering and Health, Wuhan Textile University Wuhan 430220 China
| | - Ai-Guo Shen
- School of Bioengineering and Health, Wuhan Textile University Wuhan 430220 China
- College of Chemistry and Molecular Sciences, Wuhan University Wuhan 430072 China
| |
Collapse
|
8
|
Feng X, Lin R, Yang S, Xu Y, Zhang T, Chen S, Ji Y, Wang Z, Chen S, Zhu C, Gao Z, Zhao YS. Spatially Resolved Organic Whispering-Gallery-Mode Hetero-Microrings for High-Security Photonic Barcodes. Angew Chem Int Ed Engl 2023; 62:e202310263. [PMID: 37604784 DOI: 10.1002/anie.202310263] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2023] [Revised: 08/14/2023] [Accepted: 08/21/2023] [Indexed: 08/23/2023]
Abstract
Whispering-gallery-mode (WGM) microcavities featuring distinguishable sharp peaks in a broadband exhibit enormous advantages in the field of miniaturized photonic barcodes. However, such kind of barcodes developed hitherto are primarily based on microcavities wherein multiple gain medias were blended into a single matrix, thus resulting in the limited and indistinguishable coding elements. Here, a surface tension assisted heterogeneous assembly strategy is proposed to construct the spatially resolved WGM hetero-microrings with multiple spatial colors along its circular direction. Through precisely regulating the charge-transfer (CT) strength, full-color microrings covering the entire visible range were effectively acquired, which exhibit a series of sharp and recognizable peaks and allow for the effective construction of high-quality photonic barcodes. Notably, the spatially resolved WGM hetero-microrings with multiple coding elements were finally acquired through heterogeneous nucleation and growth controlled by the directional diffusion between the hetero-emulsion droplets, thus remarkably promoting the security strength and coding capacity of the barcodes. The results would be useful to fabricate new types of organic hierarchical hybrid WGM heterostructures for optical information recording and security labels.
Collapse
Affiliation(s)
- Xingwei Feng
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Ru Lin
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Shuo Yang
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Yuyu Xu
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Tongjin Zhang
- Key Laboratory of photochemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| | - Shunwei Chen
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Yingke Ji
- Key Laboratory of Light Field Manipulation and Information Acquisition, Ministry of Industry and Information Technology, and Shanxi Key Laboratory of Optical Information Technology, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710129, China
| | - Zifei Wang
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Shiwei Chen
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Chaofeng Zhu
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Zhenhua Gao
- School of Materials Science & Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, 250353, Shandong Province, China
| | - Yong Sheng Zhao
- Key Laboratory of photochemistry, Institute of Chemistry, Chinese Academy of Sciences, Beijing, 100190, China
| |
Collapse
|
9
|
Reichstein J, Müssig S, Wintzheimer S, Mandel K. Communicating Supraparticles to Enable Perceptual, Information-Providing Matter. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023:e2306728. [PMID: 37786273 DOI: 10.1002/adma.202306728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 08/04/2023] [Indexed: 10/04/2023]
Abstract
Materials are the fundament of the physical world, whereas information and its exchange are the centerpieces of the digital world. Their fruitful synergy offers countless opportunities for realizing desired digital transformation processes in the physical world of materials. Yet, to date, a perfect connection between these worlds is missing. From the perspective, this can be achieved by overcoming the paradigm of considering materials as passive objects and turning them into perceptual, information-providing matter. This matter is capable of communicating associated digitally stored information, for example, its origin, fate, and material type as well as its intactness on demand. Herein, the concept of realizing perceptual, information-providing matter by integrating customizable (sub-)micrometer-sized communicating supraparticles (CSPs) is presented. They are assembled from individual nanoparticulate and/or (macro)molecular building blocks with spectrally differentiable signals that are either robust or stimuli-susceptible. Their combination yields functional signal characteristics that provide an identification signature and one or multiple stimuli-recorder features. This enables CSPs to communicate associated digital information on the tagged material and its encountered stimuli histories upon signal readout anywhere across its life cycle. Ultimately, CSPs link the materials and digital worlds with numerous use cases thereof, in particular fostering the transition into an age of sustainability.
Collapse
Affiliation(s)
- Jakob Reichstein
- Department of Chemistry and Pharmacy, Inorganic Chemistry, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Egerlandstraße 1, D-91058, Erlangen, Germany
| | - Stephan Müssig
- Department of Chemistry and Pharmacy, Inorganic Chemistry, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Egerlandstraße 1, D-91058, Erlangen, Germany
| | - Susanne Wintzheimer
- Department of Chemistry and Pharmacy, Inorganic Chemistry, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Egerlandstraße 1, D-91058, Erlangen, Germany
- Fraunhofer-Institute for Silicate Research ISC, Neunerplatz 2, D-97082, Würzburg, Germany
| | - Karl Mandel
- Department of Chemistry and Pharmacy, Inorganic Chemistry, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Egerlandstraße 1, D-91058, Erlangen, Germany
- Fraunhofer-Institute for Silicate Research ISC, Neunerplatz 2, D-97082, Würzburg, Germany
| |
Collapse
|
10
|
Shao ZH, Zhai A, Hua Y, Mo HL, Xie F, Zhao X, Zhao G, Zang SQ. Development of Au 8 nanocluster-based fluorescent strip immunosensor for sensitive detection of aflatoxin B 1. Anal Chim Acta 2023; 1274:341576. [PMID: 37455086 DOI: 10.1016/j.aca.2023.341576] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 06/16/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023]
Abstract
Gold clusters with intriguing chemical/physical properties have great promise in applications such as sensing and bio-imaging due to their fascinating photoluminescence character. In this study, an immunofluorescence sensor based on levonorgestrel protected atomically precise Au8 nanocluster (Au8NC) for aflatoxin B1 (AFB1) detection was fabricated due to its strong carcinogenic and mutagenic effect on humans. The prepared polymer-Au8NC nanospheres displayed bright luminescence and good stability in aqueous solution. The obtained AFB1 fluorescent strip immunosensor achieved quantitative point-of-care detection of AFB1 in less than 15 min, with high selectivity and detection limits down to 0.27 ng/mL. In addition, the recovery rates of AFB1 from tea soup ranged from 96% to 105% with relative standard deviations less than 10%. This work not only realized high-sensitively fluorescent sensing for AFB1, but also expanded the bio-applications of atomic-precise metal clusters.
Collapse
Affiliation(s)
- Zi-Hui Shao
- Henan Key Laboratory of Crystalline Molecular Functional Materials, Henan International Joint Laboratory of Tumor Theranostic Cluster Materials, Green Catalysis Center and College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China
| | - Aoqiang Zhai
- School of Basic Medical Sciences, College of medicine, Zhengzhou University, Zhengzhou, Henan, China
| | - Yue Hua
- Henan Key Laboratory of Crystalline Molecular Functional Materials, Henan International Joint Laboratory of Tumor Theranostic Cluster Materials, Green Catalysis Center and College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China
| | - Hui-Lin Mo
- Henan Key Laboratory of Crystalline Molecular Functional Materials, Henan International Joint Laboratory of Tumor Theranostic Cluster Materials, Green Catalysis Center and College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China
| | - Fuwei Xie
- Zhengzhou Tobacco Research Institute of CNTC, No.2 of Fengyang street, Zhengzhou, 450001, China
| | - Xueli Zhao
- Henan Key Laboratory of Crystalline Molecular Functional Materials, Henan International Joint Laboratory of Tumor Theranostic Cluster Materials, Green Catalysis Center and College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China.
| | - Ge Zhao
- Zhengzhou Tobacco Research Institute of CNTC, No.2 of Fengyang street, Zhengzhou, 450001, China.
| | - Shuang-Quan Zang
- Henan Key Laboratory of Crystalline Molecular Functional Materials, Henan International Joint Laboratory of Tumor Theranostic Cluster Materials, Green Catalysis Center and College of Chemistry, Zhengzhou University, Zhengzhou, 450001, China
| |
Collapse
|
11
|
Zhang J, Wu J, Chen C, He G, Liu W, Xu S, Gu H, Wang Y, Xu H. A micro-chamber free digital bio-detection for multiplexed and ultrasensitive immunoassay based on encoded magnetic microbeads and tyramide signal amplification strategy. Talanta 2023; 262:124685. [PMID: 37220690 DOI: 10.1016/j.talanta.2023.124685] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/16/2023] [Accepted: 05/17/2023] [Indexed: 05/25/2023]
Abstract
Digital bio-detection has become one of the most appealing methods in recent years due to its excellent performance with ultra-sensitivity in detection of low-abundance targets. Traditional digital bio-detection needs the utilization of micro-chambers for physical isolation of targets, while the recently developed beads-based micro-chamber free one is attracting extensive attention, although there exist the disadvantages of overlaps between positive ("1") and negative ("0") signals as well as the decreased detection sensitivity in multiplexed mode. Here we propose a feasible and robust micro-chamber free digital bio-detection for multiplexed and ultrasensitive immunoassay based on encoded magnetic microbeads (EMMs) and tyramide signal amplification (TSA) strategy. An EMMs-based multiplexed platform is constructed by using a fluorescent encoding method, then a puissant signal amplification of positive events in TSA procedure is achieved via systematical revelation of key factors influences. For proof of concept, a three-plexed tumor markers detection is performed to evaluate our established platform. The detection sensitivity is comparable to the corresponding single-plexed assays and is also approximately 30-15,000 times improvement compared to the conventional suspension chip. Therefore, this multiplexed micro-chamber free digital bio-detection paves a promising way to be an ultrasensitive and powerful tool for clinical diagnosis.
Collapse
Affiliation(s)
- Jiayu Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Jiancong Wu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Cang Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Guoqing He
- Hangzhou Joinstar Biotechnology Co., Ltd., Hangzhou, 310000, China
| | - Wei Liu
- Hangzhou Joinstar Biotechnology Co., Ltd., Hangzhou, 310000, China
| | - Sitong Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Hongchen Gu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China
| | - Yao Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China.
| | - Hong Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China.
| |
Collapse
|
12
|
Tang Y, Zheng X, Gao T. Orthogonal Combinatorial Raman Codes Enable Rapid High-Throughput-Out Library Screening of Cell-Targeting Ligands. RESEARCH (WASHINGTON, D.C.) 2023; 6:0136. [PMID: 37214198 PMCID: PMC10198463 DOI: 10.34133/research.0136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 04/14/2023] [Indexed: 05/24/2023]
Abstract
High-throughput assays play an important role in the fields of drug discovery, genetic analysis, and clinical diagnostics. Although super-capacity coding strategies may facilitate labeling and detecting large numbers of targets in a single assay, practically, the constructed large-capacity codes have to be decoded with complicated procedures or are lack of survivability under the required reaction conditions. This challenge results in either inaccurate or insufficient decoding outputs. Here, we identified chemical-resistant Raman compounds to build a combinatorial coding system for the high-throughput screening of cell-targeting ligands from a focused 8-mer cyclic peptide library. The accurate in situ decoding results proved the signal, synthetic, and functional orthogonality for this Raman coding strategy. The orthogonal Raman codes allowed for a rapid identification of 63 positive hits at one time, evidencing a high-throughput-out capability in the screening process. We anticipate this orthogonal Raman coding strategy being generalized to enable efficient high-throughput-out screening of more useful ligands for cell targeting and drug discovery.
Collapse
|
13
|
Anwar A, Mur M, Humar M. Microcavity- and Microlaser-Based Optical Barcoding: A Review of Encoding Techniques and Applications. ACS PHOTONICS 2023; 10:1202-1224. [PMID: 37215324 PMCID: PMC10197175 DOI: 10.1021/acsphotonics.2c01611] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Indexed: 05/24/2023]
Abstract
Optical microbarcodes have recently received a great deal of interest because of their suitability for a wide range of applications, such as multiplexed assays, cell tagging and tracking, anticounterfeiting, and product labeling. Spectral barcodes are especially promising because they are robust and have a simple readout. In addition, microcavity- and microlaser-based barcodes have very narrow spectra and therefore have the potential to generate millions of unique barcodes. This review begins with a discussion of the different types of barcodes and then focuses specifically on microcavity-based barcodes. While almost any kind of optical microcavity can be used for barcoding, currently whispering-gallery microcavities (in the form of spheres and disks), nanowire lasers, Fabry-Pérot lasers, random lasers, and distributed feedback lasers are the most frequently employed for this purpose. In microcavity-based barcodes, the information is encoded in various ways in the properties of the emitted light, most frequently in the spectrum. The barcode is dependent on the properties of the microcavity, such as the size, shape, and the gain materials. Various applications of these barcodes, including cell tracking, anticounterfeiting, and product labeling are described. Finally, the future prospects for microcavity- and microlaser-based barcodes are discussed.
Collapse
Affiliation(s)
- Abdur
Rehman Anwar
- Department
of Condensed Matter Physics, J. Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Maruša Mur
- Department
of Condensed Matter Physics, J. Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
| | - Matjaž Humar
- Department
of Condensed Matter Physics, J. Stefan Institute, Jamova 39, SI-1000 Ljubljana, Slovenia
- CENN
Nanocenter, Jamova 39, SI-1000 Ljubljana, Slovenia
- Faculty
of Mathematics and Physics, University of
Ljubljana, Jadranska
19, SI-1000 Ljubljana, Slovenia
| |
Collapse
|
14
|
Liu D, Sun XM, Zhu L, Li CY. Using time-shared scanning optical tweezers assisted two-photon fluorescence imaging to establish a versatile CRISPR/Cas12a-mediated biosensor. Biosens Bioelectron 2023; 227:115158. [PMID: 36827793 DOI: 10.1016/j.bios.2023.115158] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/05/2023] [Accepted: 02/15/2023] [Indexed: 02/21/2023]
Abstract
Based on the admirable precision to identify target nucleic acids and the particular trans-cleavage feature, CRISPR/Cas12a system is a useful means to further improve the sensing accuracy and the design flexibility of fluorescence biosensors. However, the current construction concepts still suffer from insufficient sensitivity, unsuitable for complicated real samples and limited detection species. In this work, much efforts are achieved to address these obstacles. At first, we adopt a microsphere sustained signal enrichment, under which a home-made time-shared scanning optical tweezers assisted fluorescence imaging is employed to guarantee a stable excitation and also realize multiflux measurement. Furthermore, by taking advantage of the low background merit of the near-infrared light excited two-photon fluorescence, a commendable anti-interference capability is endowed to operate in complex media. After utilizing a functional DNA (e.g. aptamer and DNAzyme) regulated mediation pathway to respond non-nucleic acid analytes (alpha fetal protein and Pb2+), the newly-established CRISPR/Cas12a-mediated fluorescence biosensor is found to display favorable assay performance. More importantly, our analytical methodology can act as a versatile and reliable toolbox in various applications such as disease diagnosis and environmental analysis, propelling the development of CRISPR system in biosensing field.
Collapse
Affiliation(s)
- Da Liu
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, PR China
| | - Xiao-Ming Sun
- School of Basic Medical Sciences, Biomedical Research Institute, Hubei University of Medicine, Shiyan, 442000, PR China
| | - Lian Zhu
- School of Chemistry and Environmental Engineering, Wuhan Polytechnic University, Wuhan, 430023, PR China
| | - Cheng-Yu Li
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, PR China.
| |
Collapse
|
15
|
Li Z, Ma H, Guo Y, Fang H, Zhu C, Xue J, Wang W, Luo G, Sun Y. Synthesis of uniform Pickering microspheres doped with quantum dot by microfluidic technology and its application in tumor marker. Talanta 2023; 262:124495. [DOI: 10.1016/j.talanta.2023.124495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 03/23/2023] [Accepted: 03/27/2023] [Indexed: 03/31/2023]
|
16
|
Wei X, Shang Y, Zhu Y, Gu Z, Zhang D. Encoding microcarriers for biomedicine. SMART MEDICINE 2023; 2:e20220009. [PMID: 39188559 PMCID: PMC11235794 DOI: 10.1002/smmd.20220009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 09/22/2022] [Indexed: 08/28/2024]
Abstract
High throughput biological analysis has become an important topic in modern biomedical research and clinical diagnosis. The flow encoding scheme based on the encoding microcarriers provides a feasible strategy for the multiplexed biological analysis. Different encoding characteristics invest the microcarriers with different encoding mechanisms. Biosensor analysis, drug screening, cell culture, and the construction and evaluation of bionic organ chips can be realized by decoding the microcarriers and quantifying the detection signal intensity. In this review, the encoding strategy of microcarriers was divided into the optical and non-optical encoding approaches according to their encoding elements, and the research progress of the microcarrier encoding strategy was elaborated. Finally, we summarized the biomedical applications and predicted their future prospects.
Collapse
Affiliation(s)
- Xiaowei Wei
- Laboratory Medicine CenterThe Second Affiliated Hospital of Nanjing Medical UniversityNanjingChina
- Department of Clinical LaboratoryInstitute of Translational MedicineThe Affiliated Drum Tower Hospital of Nanjing University Medical SchoolNanjingChina
| | - Yixuan Shang
- Department of Clinical LaboratoryInstitute of Translational MedicineThe Affiliated Drum Tower Hospital of Nanjing University Medical SchoolNanjingChina
| | - Yefei Zhu
- Laboratory Medicine CenterThe Second Affiliated Hospital of Nanjing Medical UniversityNanjingChina
| | - Zhuxiao Gu
- Department of Clinical LaboratoryInstitute of Translational MedicineThe Affiliated Drum Tower Hospital of Nanjing University Medical SchoolNanjingChina
| | - Dagan Zhang
- Department of Clinical LaboratoryInstitute of Translational MedicineThe Affiliated Drum Tower Hospital of Nanjing University Medical SchoolNanjingChina
| |
Collapse
|
17
|
Malhotra K, Hrovat D, Kumar B, Qu G, Houten JV, Ahmed R, Piunno PAE, Gunning PT, Krull UJ. Lanthanide-Doped Upconversion Nanoparticles: Exploring A Treasure Trove of NIR-Mediated Emerging Applications. ACS APPLIED MATERIALS & INTERFACES 2023; 15:2499-2528. [PMID: 36602515 DOI: 10.1021/acsami.2c12370] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Lanthanide-doped upconversion nanoparticles (UCNPs) possess the remarkable ability to convert multiple near-infrared (NIR) photons into higher energy ultraviolet-visible (UV-vis) photons, making them a prime candidate for several advanced applications within the realm of nanotechnology. Compared to traditional organic fluorophores and quantum dots (QDs), UCNPs possess narrower emission bands (fwhm of 10-50 nm), large anti-Stokes shifts, low toxicity, high chemical stability, and resistance to photobleaching and blinking. In addition, unlike UV-vis excitation, NIR excitation is nondestructive at lower power intensities and has high tissue penetration depths (up to 2 mm) with low autofluorescence and scattering. Together, these properties make UCNPs exceedingly favored for advanced bioanalytical and theranostic applications, where these systems have been well-explored. UCNPs are also well-suited for bioimaging, optically modulating chemistries, forensic science, and other state-of-the-art research applications. In this review, an up-to-date account of emerging applications in UCNP research, beyond bioanalytical and theranostics, are presented including optogenetics, super-resolution imaging, encoded barcodes, fingerprinting, NIR vision, UCNP-assisted photochemical manipulations, optical tweezers, 3D printing, lasing, NIR-II imaging, UCNP-molecule nanohybrids, and UCNP-based persistent luminescent nanocrystals.
Collapse
Affiliation(s)
- Karan Malhotra
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - David Hrovat
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
- Gunning Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Balmiki Kumar
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Grace Qu
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Justin Van Houten
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Reda Ahmed
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Paul A E Piunno
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Patrick T Gunning
- Gunning Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| | - Ulrich J Krull
- Chemical Sensors Group, Department of Chemical and Physical Sciences, University of Toronto Mississauga, Mississauga, OntarioL5L 1C6, Canada
| |
Collapse
|
18
|
Liu J, Zhang L, Zeng W, Zhang L, He N, Lu Z. High-throughput quantitative detection of triple-negative breast cancer-associated expressed miRNAs by rolling circle amplification on fluorescence-encoded microspheres. CHINESE CHEM LETT 2023. [DOI: 10.1016/j.cclet.2023.108141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
19
|
Liu X, Li M, Yu X, Shen L, Li W. Silent region barcode particle arrays for ultrasensitive multiplexed SERS detection. Biosens Bioelectron 2023; 219:114804. [PMID: 36272345 DOI: 10.1016/j.bios.2022.114804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 09/30/2022] [Accepted: 10/10/2022] [Indexed: 11/19/2022]
Abstract
Suspension arrays are a critical components of next generation multiplexed detection technologies. Current fluorescence suspension arrays are limited by a multiplexed coding ceiling and difficulties with ultrasensitive detection. Raman mode is a promising substitute, but the complex spectral peak distributions and extremely weak intrinsic signal intensity severely diminish Raman signal performance in suspension arrays. To address these limitations, we constructed a Raman suspension array system using plasmonic microbeads as barcode substrates and Au nanoflowers as reporter carriers. The well-designed shell morphology and plasmonic microbead composition enabled significant surface enhancement Raman scattering (SERS) such that we were able to adjust silent region Raman-coding intensity levels. Due to synergistic SERS effects from the plasmonic shell and the multi-branched Au nanoflower nanostructure, the reporting signal was greatly improved, enabling ultrasensitive detection of 5-plexed lung cancer markers. Detection in patient serum samples demonstrated good consistency with the standard electrochemiluminescence method. Thus, this silent region SERS barcode-based suspension array is a developmental advance for modern multiplexed biodetection, potentially providing a powerful early disease screening and diagnosis tool.
Collapse
Affiliation(s)
- Xinyi Liu
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering, Zhangjiang Institute for Advanced Study, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China
| | - Meng Li
- Zhejiang Orient Gene Biotech Co., Ltd., 3787 East Yangguang Avenue, Anji, 313300, Zhejiang, PR China
| | - Xujiang Yu
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering, Zhangjiang Institute for Advanced Study, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China
| | - Lisong Shen
- Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Jiao Tong University, 1665 Kongjiang Road, Shanghai, 200092, PR China
| | - Wanwan Li
- State Key Lab of Metal Matrix Composites, School of Materials Science and Engineering, Zhangjiang Institute for Advanced Study, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China.
| |
Collapse
|
20
|
Sha Z, Wang C, Ma R, Gao X, Sun S. Microfluidic synthesis of Janus-structured QD-encoded magnetic microbeads for multiplex immunoassay. Mikrochim Acta 2022; 189:407. [PMID: 36198915 DOI: 10.1007/s00604-022-05507-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 09/26/2022] [Indexed: 10/10/2022]
Abstract
Uniform and monodisperse quantum dot (QD)-encoded magnetic microbeads with Janus structure were produced in a microfluidic device via photopolymerization. UV light through a microscope objective was used to solidify the microbeads which showed sharp interfaces and excellent magnetic responses. QDs with different emission peaks (450 nm for blue and 640 nm for red) were mixed at different ratios to provide three spectral codes. The QD-encoded microbeads can be distinguished by analyzing their fluorescent images in HSV color space. After hydrolysis of the anhydride group in alkaline solution, protein was immobilized on microbeads via activation of carboxyl groups using (1-ethyl-3(3-dimethylaminoprophyl) carbodiimide/N-hydroxysuccinimide (EDC/NHS). A microhole array in polydimethylsiloxane (PDMS) substrates with a specific size was fabricated to trap individual microbeads in a single microhole. The combination of Janus-structured QD-encoded magnetic microbeads and microhole arrays facilitates both flexibility, binding kinetics, sensitivity for suspension assay, and fluorescence mapping analysis for conventional biochips, thus providing a novel platform for multiplex bioanalysis. The capability of this integration for multiplex immunoassays was verified using three kinds of IgG and their corresponding anti-IgG. A detection limit of 0.07 ng/mL was achieved for human IgG, indicating practical applications in various fields.
Collapse
Affiliation(s)
- Zhou Sha
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Chunnan Wang
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Rui Ma
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Xiaochun Gao
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Shuqing Sun
- Institute of Biopharmaceutical and Healthcare Engineering, Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China.
| |
Collapse
|
21
|
Zhu T, Chen J, Chai Q, Zeng S, Liu Y. Stable and sensitive sensor for alkaline phosphatase based on target-triggered wavelength tuning of fluorescent copper nanoclusters. Anal Chim Acta 2022; 1232:340453. [DOI: 10.1016/j.aca.2022.340453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 09/23/2022] [Accepted: 09/25/2022] [Indexed: 11/01/2022]
|
22
|
DiSalvo M, Cortés-Llanos B, LaBelle CA, Murdoch DM, Allbritton NL. Scalable Additive Construction of Arrayed Microstructures with Encoded Properties for Bioimaging. MICROMACHINES 2022; 13:1392. [PMID: 36144015 PMCID: PMC9500771 DOI: 10.3390/mi13091392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 08/20/2022] [Accepted: 08/23/2022] [Indexed: 06/16/2023]
Abstract
Microarrays are essential components of analytical instruments. The elements of microarrays may be imbued with additional functionalities and encodings using composite materials and structures, but traditional microfabrication methods present substantial barriers to fabrication, design, and scalability. In this work, a tool-free technique was reported to additively batch-construct micromolded, composite, and arrayed microstructures. The method required only a compatible carrier fluid to deposit a material onto a substrate with some topography. Permutations of this basic fabrication approach were leveraged to gain control over the volumes and positions of deposited materials within the microstructures. As a proof of concept, cell micro-carrier arrays were constructed to demonstrate a range of designs, compositions, functionalities, and applications for composite microstructures. This approach is envisioned to enable the fabrication of complex composite biological and synthetic microelements for biosensing, cellular analysis, and biochemical screening.
Collapse
Affiliation(s)
- Matthew DiSalvo
- Microsystems and Nanotechnology Division, National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
| | - Belén Cortés-Llanos
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
- Department of Medicine, Duke University Medical Center, Durham, NC 27705, USA
| | - Cody A. LaBelle
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
| | - David M. Murdoch
- Department of Medicine, Duke University Medical Center, Durham, NC 27705, USA
| | - Nancy L. Allbritton
- Department of Bioengineering, University of Washington, Seattle, WA 98105, USA
| |
Collapse
|
23
|
Luminescence encoding of polymer microbeads with organic dyes and semiconductor quantum dots during polymerization. Sci Rep 2022; 12:12061. [PMID: 35835808 PMCID: PMC9283474 DOI: 10.1038/s41598-022-16065-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 07/04/2022] [Indexed: 01/15/2023] Open
Abstract
Luminescence-encoded microbeads are important tools for many applications in the life and material sciences that utilize luminescence detection as well as multiplexing and barcoding strategies. The preparation of such beads often involves the staining of premanufactured beads with molecular luminophores using simple swelling procedures or surface functionalization with layer-by-layer (LbL) techniques. Alternatively, these luminophores are sterically incorporated during the polymerization reaction yielding the polymer beads. The favorable optical properties of semiconductor quantum dots (QDs), which present broadly excitable, size-tunable, narrow emission bands and low photobleaching sensitivity, triggered the preparation of beads stained with QDs. However, the colloidal nature and the surface chemistry of these QDs, which largely controls their luminescence properties, introduce new challenges to bead encoding that have been barely systematically assessed. To establish a straightforward approach for the bead encoding with QDs with minimized loss in luminescence, we systematically assessed the incorporation of oleic acid/oleylamine-stabilized CdSe/CdS-core/shell-QDs into 0.5-2.5 µm-sized polystyrene (PS) microspheres by a simple dispersion polymerization synthesis that was first optimized with the organic dye Nile Red. Parameters addressed for the preparation of luminophore-encoded beads include the use of a polymer-compatible ligand such as benzyldimethyloctadecylammonium chloride (OBDAC) for the QDs, and crosslinking to prevent luminophore leakage. The physico-chemical and optical properties of the resulting beads were investigated with electron microscopy, dynamic light scattering, optical spectroscopy, and fluorescence microscopy. Particle size distribution, fluorescence quantum yield of the encapsulated QDs, and QD leaking stability were used as measures for bead quality. The derived optimized bead encoding procedure enables the reproducible preparation of bright PS microbeads encoded with organic dyes as well as with CdSe/CdS-QDs. Although these beads show a reduced photoluminescence quantum yield compared to the initially very strongly luminescent QDs, with values of about 35%, their photoluminescence quantum yield is nevertheless still moderate.
Collapse
|
24
|
Tang WS, Zhang B, Xu LD, Bao N, Zhang Q, Ding SN. CdSe/ZnS quantum dot-encoded maleic anhydride-grafted PLA microspheres prepared through membrane emulsification for multiplexed immunoassays of tumor markers. Analyst 2022; 147:1873-1880. [PMID: 35420086 DOI: 10.1039/d2an00350c] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Early diagnosis of tumor markers is of great importance for the successful treatment of cancer. As a high-throughput and high-sensitivity detection technology, liquid suspension biochips based on quantum dot (QD) encoded microspheres have been widely used in the immunodetection of tumor markers. In this work, maleic anhydride grafted PLA (PLA-MA) microspheres based on quantum dot encoding were used as carriers for liquid phase suspension biochips for the immunoassay of tumor markers. PLA-MA fluorescent beads are prepared by embedding CdSe/ZnS quantum dots in PLA-MA using Shirasu porous glass (SPG) membrane emulsification technology, which has high fluorescence intensity, good stability, and good dispersion. Fluorescent immunoassays on dipsticks found that PLA-MA microspheres have high biological activity and good stability, which is conducive to immunoassays. Based on this, using the characteristics of CdSe/ZnS quantum dots and flow cytometry, monochromatic and two-color coding methods were developed, and 9 distinguishable coding beads were prepared. The results showed that PLA-MA fluorescent microspheres exhibited good biocompatibility, stable coding signals, low background noise, and low detection limits when performing quaternary immunoassays on tumor markers CA125, CA199, CA724, and CEA by CdSe/ZnS QD-encoded PLA-MA microsphere binding flow cytometry.
Collapse
Affiliation(s)
- Wan-Sheng Tang
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| | - Bo Zhang
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| | - Lai-Di Xu
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| | - Ning Bao
- School of Public Health, Nantong University, 226019 Nantong, Jiangsu, China
| | - Qing Zhang
- Chinese Academy of Inspection and Quarantine, Beijing, China
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| |
Collapse
|
25
|
Dual-Signal-Encoded Barcodes with Low Background Signal for High-Sensitivity Analysis of Multiple Tumor Markers. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10040142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The suspension array technology (SAT) is promising for high-sensitivity multiplexed analysis of tumor markers. Barcodes as the core elements of SAT, can generate encoding fluorescence signals (EFS) and detection fluorescence signals (DFS) in the corresponding flow cytometer channel. However, the bleed-through effect of EFS in the DFS channel and the reagent-driven non-specific binding (NSB) lead to background interference for ultrasensitive assay of multiple targets. Here, we report an ingenious method to eliminate background interference between barcode and reporter using low-background dual-signal-encoded barcodes (DSBs) based on microbeads (MBs) and quantum dots (QDs). The low-background DSBs were prepared via combination strategy of two signals containing scatter signals and fluorescence signals. Three types of MBs were distinguished by the scattering channel of flow cytometer (FSC vs. SSC) to obtain the scattered signals. Green quantum dots (GQDs) or red quantum dots (RQDs) were coupled to the surface of MBs by sandwich immune structure to obtain the distinguishable fluorescent signals. Furthermore, the amount of conjugated capture antibody on the MB’s surface was optimized by comparing the change of detection sensitivity with the addition of capture antibody. The combination measurements of specificity and NSB in SAT platform were performed by incubating the capture antibody-conjugated MBs (cAb-MBs) with individual QD-conjugated detection antibody (QDs-dAb). Finally, an SAT platform based on DSBs was successfully established for highly sensitive multiplexed analysis of six tumor markers in one test, which suggests the promising tool for highly sensitive multiplexed bioassay applications.
Collapse
|
26
|
Wang Y, Gao Y, Yin Y, Pan Y, Wang Y, Song Y. Nanomaterial-assisted microfluidics for multiplex assays. Mikrochim Acta 2022; 189:139. [PMID: 35275267 DOI: 10.1007/s00604-022-05226-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 02/10/2022] [Indexed: 02/07/2023]
Abstract
Simultaneous detection of different biomarkers from a single specimen in a single test, allowing more rapid, efficient, and low-cost analysis, is of great significance for accurate diagnosis of disease and efficient monitoring of therapy. Recently, developments in microfabrication and nanotechnology have advanced the integration of nanomaterials in microfluidic devices toward multiplex assays of biomarkers, combining both the advantages of microfluidics and the unique properties of nanomaterials. In this review, we focus on the state of the art in multiplexed detection of biomarkers based on nanomaterial-assisted microfluidics. Following an overview of the typical microfluidic analytical techniques and the most commonly used nanomaterials for biochemistry analysis, we highlight in detail the nanomaterial-assisted microfluidic strategies for different biomarkers. These highly integrated platforms with minimum sample consumption, high sensitivity and specificity, low detection limit, enhanced signals, and reduced detection time have been extensively applied in various domains and show great potential in future point-of-care testing and clinical diagnostics.
Collapse
Affiliation(s)
- Yanping Wang
- Sino-French Engineer School, Nanjing University of Science and Technology, Nanjing, 210094, China
| | - Yanfeng Gao
- College of Engineering and Applied Sciences, Jiangsu Key Laboratory of Artificial Functional Materials, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210023, China
| | - Yi Yin
- Department of General Surgery, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, 210008, China
| | - Yongchun Pan
- College of Engineering and Applied Sciences, Jiangsu Key Laboratory of Artificial Functional Materials, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210023, China
| | - Yuzhen Wang
- Key Laboratory of Flexible Electronics & Institute of Advanced Materials, Jiangsu National Synergistic Innovation Center for Advanced Materials, Nanjing Tech University, Nanjing, 211816, China
| | - Yujun Song
- College of Engineering and Applied Sciences, Jiangsu Key Laboratory of Artificial Functional Materials, State Key Laboratory of Analytical Chemistry for Life Science, Nanjing University, Nanjing, 210023, China.
| |
Collapse
|
27
|
Du X, Wang Y, Zhai J, Guo C, Zhang Y, Huang W, Ma X, Xie X. One-pot synthesized organosilica nanospheres for multiplexed fluorescent nanobarcoding and subcellular tracking. NANOSCALE 2022; 14:1787-1795. [PMID: 35029611 DOI: 10.1039/d1nr06540h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Multicolor microbeads are widely used in flow cytometry for various cellular and immunoassays. However, they are limited by their large size of around one to tens of micrometers. Nanomaterials for multiplexed analysis are emerging as valuable tools in high-throughput assays and fluorescence cell barcoding. We present barcoding and related cellular studies based on mass-produced organosilane-derived multifunctional nanospheres with a uniform size. Functional groups including thiols, amines, and azides were integrated in one step from various organosilanes without additional orthosilicates. Fluorescent nanobarcodes (NBs) were achieved through flexible physical adsorption and chemical ligation of spectrally separated fluorescent dyes. Live cells labeled with the NBs were readily distinguished by flow cytometry. The NBs have a small and uniform size (ca. 27 nm in diameter), excellent biocompatibility, rapid cellular uptake, and low dye leakage. The fluorescent nanospheres were applied for long-term cell tracking during multiple rounds of cell division and monitored over 48 hours. While most nanospheres were endolysosome-targeting, modification with fluorescein isothiocyanate (FITC) surprisingly lighted up the cell nucleus. This work lays the foundation of a unique family of functional nanomaterials promising for multiplex detection and other chemical and biological applications.
Collapse
Affiliation(s)
- Xinfeng Du
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| | - Yifu Wang
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| | - Jingying Zhai
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Chao Guo
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| | - Yupu Zhang
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| | - Wenyu Huang
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| | - Xueqing Ma
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen, 518055, China
| | - Xiaojiang Xie
- Department of Chemistry, Southern University of Science and Technology, Shenzhen, 518055, China.
| |
Collapse
|
28
|
Ji DD, Wu MX, Ding SN. Photonic crystal barcodes assembled from dendritic silica nanoparticles for the multiplex immunoassays of ovarian cancer biomarkers. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:298-305. [PMID: 34985054 DOI: 10.1039/d1ay01658j] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The combined detection of CA125, CEA and AFP is of great significance in the diagnosis of ovarian cancer. Photonic crystal (PhC) barcodes have apparent advantages in multiplex immunoassays of ovarian cancer markers. In this paper, a novel PhC barcode was assembled from dendritic silica nanoparticles (dSiO2) for multiplex detection of ovarian cancer biomarkers. The interconnected macroporous structure of the dSiO2 PhC beads and the open porous topography of dendritic silica particles could increase the surface area to volume ratio for antibody immobilization. We simultaneously detected multiple ovarian cancer markers in one test tube using the sandwich immunization method by utilizing dSiO2 PhC beads as a barcode and CdTe QDs as a detection signal. The detection limits of the three ovarian cancer markers, AFP, CEA and CA125, were 0.52 ng mL-1, 0.64 ng mL-1 and 0.79 U mL-1, respectively (the signal-to-noise ratio was 3). Compared with the classic silica colloidal crystal bead (SCCB) suspension array, the sensitivity of the dSiO2 PhC bead suspension array was increased. In addition, the results showed that this barcode suspension array had acceptable accuracy and good reproducibility.
Collapse
Affiliation(s)
- Dan-Dan Ji
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| | - Mei-Xia Wu
- Lianshui People's Hospital, Jiangsu 223400, China
| | - Shou-Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
| |
Collapse
|
29
|
Feng Z, Guo Q, Wang Y, Ge Y, Zhang Z, Wu Y, Li Q, Masoomi H, Gu H, Xu H. Evolution of "On-Barcode" Luminescence Oxygen Channeling Immunoassay by Exploring the Barcode Structure and the Assay System. ACS OMEGA 2022; 7:2344-2355. [PMID: 35071922 PMCID: PMC8772307 DOI: 10.1021/acsomega.1c06236] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Accepted: 12/23/2021] [Indexed: 06/14/2023]
Abstract
The multiplexed luminescence oxygen channeling immunoassay (multi-LOCI) platform we developed recently that combines conventional LOCI and suspension array technology is capable of realizing facile "mix-and-measure" multiplexed assays without tedious washing steps. However, previous work lacks comprehensive studies of the structure-performance relationship of the host-guest-structured barcode, which may obstruct the evolution and further translation of this exciting new technology to practical applications. Accordingly, this work revealed that polyelectrolyte interlayers played a crucial role in tuning the packing density of guest acceptor beads (ABs). More interestingly, we noticed that "sparse" barcodes (barcodes with low ABs packing density) exhibited comparable assay performance with "compact" ones (barcodes with high ABs packing density). The high robustness of barcodes allows for multi-LOCI to be a more universal and flexible assay platform. Furthermore, through optimization of the assay system including the laser power, as well as the concentrations of donor beads and biotinylated detection antibodies, the multi-LOCI platform showed a significant improvement in sensitivity compared with our previous work, with the limit of detection decreasing to as low as ca. 1 pg/mL. Impressively, multi-LOCI that enabled simultaneous detection of multiple analytes exhibited comparable sensitivity with the classical single-plexed LOCI, due to the ingenious structural design of the multi-LOCI barcode and the unique "on-barcode" assay format.
Collapse
Affiliation(s)
- Zuying Feng
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Qingsheng Guo
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Yao Wang
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Yunfei Ge
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Zhiying Zhang
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Yan Wu
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Qilong Li
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Hajar Masoomi
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
- School
of Integrated Technology, Gwangju Institute
of Science and Technology, Gwangju 61005, South Korea
| | - Hongchen Gu
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| | - Hong Xu
- School
of Biomedical Engineering, Shanghai Jiao
Tong University, Shanghai 200030, P. R. China
| |
Collapse
|
30
|
Guo C, Zhai J, Wang Y, Du X, Wang Z, Xie X. Photoswitch-Based Fluorescence Encoding of Microspheres in a Limited Spectral Window for Multiplexed Detection. Anal Chem 2022; 94:1531-1536. [PMID: 35025214 DOI: 10.1021/acs.analchem.1c04856] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Fluorescence barcoding with multicolor fluorophores is limited by spectral crowding. Herein, we propose a fluorescence encoding method in a single-color channel with photoswitches. The photochromic naphthopyran was used to mediate the fluorescence of polystyrene microspheres through resonance energy transfer. The initial fluorescence intensity (F0) and the fluorescence after UV light activation (F/F0) were combined to generate hundreds of 2-dimensional barcodes. The coding capacity was further expanded with the different chemical kinetics of the photoswitches. The photoswitch-based fluorescence barcodes were applied to simultaneously and selectively detect the DNA sequences of COVID-19 (with related mutations) as a proof-of-concept for real applications. The compatibility with the state-of-the-art fluorescence microscopes and simple encoding and decoding make the method very attractive for multiplexed and high-throughput analyses.
Collapse
Affiliation(s)
- Chao Guo
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Jingying Zhai
- Academy for Advanced Interdisciplinary Studies, Southern University of Science and Technology, Shenzhen 518055, China
| | - Yifu Wang
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Xinfeng Du
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Zige Wang
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| | - Xiaojiang Xie
- Department of Chemistry, Southern University of Science and Technology, Shenzhen 518055, China
| |
Collapse
|
31
|
Li B, Lin J, Huang P, Chen X. Near-infrared probes for luminescence lifetime imaging. Nanotheranostics 2022; 6:91-102. [PMID: 34976583 PMCID: PMC8671960 DOI: 10.7150/ntno.63124] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 06/29/2021] [Indexed: 12/12/2022] Open
Abstract
Biomedical luminescence imaging in the near-infrared (NIR, 700-1700 nm) region has shown great potential in visualizing biological processes and pathological conditions at cellular and animal levels, owing to the reduced tissue absorption and scattering compared to light in the visible (400-700 nm) region. To overcome the background interference and signal attenuation during intensity-based luminescence imaging, lifetime imaging has demonstrated a reliable imaging modality complementary to intensity measurement. Several selective or environment-responsive probes have been successfully developed for luminescence lifetime imaging and multiplex detection. This review summarizes recent advances in the application of luminescence lifetime imaging at cellular and animal levels in NIR-I and NIR-II regions. Finally, the challenges and further directions of luminescence lifetime imaging are also discussed.
Collapse
Affiliation(s)
- Benhao Li
- Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China
- Departments of Diagnostic Radiology, Surgery, Chemical and Biomolecular Engineering, and Biomedical Engineering, Yong Loo Lin School of Medicine and Faculty of Engineering, National University of Singapore, Singapore, 119074, Singapore
- Clinical Imaging Research Centre, Centre for Translational Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
- Nanomedicine Translational Research Program, NUS Center for Nanomedicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117597, Singapore
| | - Jing Lin
- Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China
| | - Peng Huang
- Marshall Laboratory of Biomedical Engineering, International Cancer Center, Laboratory of Evolutionary Theranostics (LET), School of Biomedical Engineering, Shenzhen University Health Science Center, Shenzhen 518060, China
| | - Xiaoyuan Chen
- Departments of Diagnostic Radiology, Surgery, Chemical and Biomolecular Engineering, and Biomedical Engineering, Yong Loo Lin School of Medicine and Faculty of Engineering, National University of Singapore, Singapore, 119074, Singapore
- Clinical Imaging Research Centre, Centre for Translational Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117599, Singapore
- Nanomedicine Translational Research Program, NUS Center for Nanomedicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117597, Singapore
| |
Collapse
|
32
|
Wu W, Liu X, Li W. Progress and challenges in functional nanomaterial‐based suspension array technology for multiplexed biodetection. VIEW 2022. [DOI: 10.1002/viw.20200140] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Affiliation(s)
- Weijie Wu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University Shanghai P. R. China
| | - Xinyi Liu
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University Shanghai P. R. China
| | - Wanwan Li
- State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering Shanghai Jiao Tong University Shanghai P. R. China
| |
Collapse
|
33
|
Shao S, Man H, Nie Y, Wang Y, Xu Q, Wang Z, Jiang Y. Preparation of fluorescence-encoded microbeads with large encoding capacities and application of suspension array technology. NEW J CHEM 2022. [DOI: 10.1039/d2nj00628f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This research study reported a type of reconstructed polystyrene microbeads for fluorescence encoding in suspension array technology (SAT). The present study improved their surface functionalization and compatibility with dyes.
Collapse
Affiliation(s)
- Shimin Shao
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Hong Man
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yingrui Nie
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yang Wang
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Qianrui Xu
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Zhifei Wang
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yong Jiang
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
34
|
Yang S, Zhan X, Tang X, Zhao S, Yu L, Gao M, Luo D, Wang Y, Chang K, Chen M. A multiplexed circulating tumor DNA detection platform engineered from 3D-coded interlocked DNA rings. Bioact Mater 2021; 10:68-78. [PMID: 34901530 PMCID: PMC8637011 DOI: 10.1016/j.bioactmat.2021.09.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 08/24/2021] [Accepted: 09/03/2021] [Indexed: 12/31/2022] Open
Abstract
Circulating tumor DNA (ctDNA) is a critical biomarker not only important for the early detection of tumors but also invaluable for personalized treatments. Currently ctDNA detection relies on sequencing. Here, a platform termed three-dimensional-coded interlocked DNA rings (3D-coded ID rings) was created for multiplexed ctDNA identification. The ID rings provide a ctDNA recognition ring that is physically interlocked with a reporter ring. The specific binding of ctDNA to the recognition ring initiates target-responsive cutting via a restriction endonuclease; the cutting then triggers rolling circle amplification on the reporter ring. The signals are further integrated with internal 3D codes for multiplexed readouts. ctDNAs from non-invasive clinical specimens including plasma, feces, and urine were detected and validated at a sensitivity much higher than those obtained through sequencing. This 3D-coded ID ring platform can detect any multiple DNA fragments simultaneously without sequencing. We envision that our platform will facilitate the implementation of future personalized/precision medicine. A platform termed 3D-coded ID rings was created for multiplexed ctDNA detection. This platform was integrated with two schemes: the ID ring scheme and the 3D-coded scheme. The platform could achieve multiplexed detection with detection limit of 500 copies per million in non-invasive specimens.
Collapse
Affiliation(s)
- Sha Yang
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Xinyu Zhan
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Xiaoqi Tang
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Shuang Zhao
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Lianyu Yu
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Mingxuan Gao
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Dan Luo
- Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY, 14853-5701, USA
| | - Yunxia Wang
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Kai Chang
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| | - Ming Chen
- Department of Clinical Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China.,College of Pharmacy and Laboratory Medicine, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China.,State Key Laboratory of Trauma, Burn and Combined Injury, Third Military Medical University (Army Medical University), 30 Gaotanyan, Shapingba District, Chongqing, 400038, China
| |
Collapse
|
35
|
Castro RC, Saraiva MLM, Santos JL, Ribeiro DS. Multiplexed detection using quantum dots as photoluminescent sensing elements or optical labels. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.214181] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
36
|
Saini RV, Vaid P, Saini NK, Siwal SS, Gupta VK, Thakur VK, Saini AK. Recent Advancements in the Technologies Detecting Food Spoiling Agents. J Funct Biomater 2021; 12:67. [PMID: 34940546 PMCID: PMC8709279 DOI: 10.3390/jfb12040067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/08/2021] [Accepted: 11/22/2021] [Indexed: 12/12/2022] Open
Abstract
To match the current life-style, there is a huge demand and market for the processed food whose manufacturing requires multiple steps. The mounting demand increases the pressure on the producers and the regulatory bodies to provide sensitive, facile, and cost-effective methods to safeguard consumers' health. In the multistep process of food processing, there are several chances that the food-spoiling microbes or contaminants could enter the supply chain. In this contest, there is a dire necessity to comprehend, implement, and monitor the levels of contaminants by utilizing various available methods, such as single-cell droplet microfluidic system, DNA biosensor, nanobiosensor, smartphone-based biosensor, aptasensor, and DNA microarray-based methods. The current review focuses on the advancements in these methods for the detection of food-borne contaminants and pathogens.
Collapse
Affiliation(s)
- Reena V. Saini
- Department of Biotechnology, MMEC, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala 133207, India;
| | - Prachi Vaid
- Department of Biotechnology, School of Sciences, AP Goyal Shimla University, Shimla 171009, India;
| | - Neeraj K. Saini
- School of Biotechnology, Jawaharlal Nehru University, New Delhi 110067, India;
| | - Samarjeet Singh Siwal
- Department of Chemistry, MMEC, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala 133207, India;
| | - Vijai Kumar Gupta
- Biorefining and Advanced Materials Research Center, Scotland’s Rural College (SRUC), Kings Buildings, Edinburgh EH9 3JG, UK;
| | - Vijay Kumar Thakur
- Biorefining and Advanced Materials Research Center, Scotland’s Rural College (SRUC), Kings Buildings, Edinburgh EH9 3JG, UK;
- School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun 248007, India
| | - Adesh K. Saini
- Department of Biotechnology, School of Sciences, AP Goyal Shimla University, Shimla 171009, India;
| |
Collapse
|
37
|
Feng X, Yang X, Li M, Qin Y, Li H, Xie Y. Production and method optimization of fluorescent polystyrene. J Mol Struct 2021. [DOI: 10.1016/j.molstruc.2021.130746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
38
|
Xu L, Wang S, Zhu J, Zhou T, Ding S. Dendritic Silica Nanospheres Loaded with Red‐Emissive Enhanced Carbon Dots for Zika Virus Immunoassay. ChemistrySelect 2021. [DOI: 10.1002/slct.202102274] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Lai‐Di Xu
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research School of Chemistry and Chemical Engineering Southeast University Nanjing 211189 P.R. China
| | - Si‐Wen Wang
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research School of Chemistry and Chemical Engineering Southeast University Nanjing 211189 P.R. China
| | - Jin Zhu
- Huadong Medical Institute of Biotechniques Nanjing 211189 P.R. China
| | - Tingting Zhou
- Huadong Medical Institute of Biotechniques Nanjing 211189 P.R. China
| | - Shou‐Nian Ding
- Jiangsu Province Hi-Tech Key Laboratory for Bio-medical Research School of Chemistry and Chemical Engineering Southeast University Nanjing 211189 P.R. China
| |
Collapse
|
39
|
Affiliation(s)
- Gungun Lin
- Institute for Biomedical Materials and Devices Faculty of Science University of Technology Sydney Ultimo New South Wales Australia
- ARC Research Hub for Integrated Device for End‐User Analysis at Low Levels Faculty of Science University of Technology Sydney Sydney New South Wales Australia
| |
Collapse
|
40
|
Lin HY, Zhou LY, Xu L. Photocatalysis in Supramolecular Fluorescent Metallacycles and Metallacages. Chem Asian J 2021; 16:3805-3816. [PMID: 34529337 DOI: 10.1002/asia.202100942] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 09/13/2021] [Indexed: 11/08/2022]
Abstract
The utilization of photocatalytic techniques for achieving light-to-fuel conversion is a promising way to ease the shortage of energy and degradation of the ecological environment. Fluorescent metallacycles and metallacages have drawn considerable attention and have been used in widespread fields due to easy preparation and their abundant functionality including photocatalysis. This review covers recent advances in photocatalysis in discrete supramolecular fluorescent metallacycles and metallacages. The developments in the utilization of the metallacycles skeletons and the effect of fluorescence-resonance energy transfer for photocatalysis are discussed. Furthermore, the use of the ligands decorated by organic chromophores or redox metal sites in metallacages as photocatalysts and their ability to encapsulate appropriate catalytic cofactors for photocatalysis are summarized. For the sake of brevity, macrocycles and cages with inorganic coordination complexes such as ruthenium complexes and iridium complexes are not included in this minireview.
Collapse
Affiliation(s)
- Hong-Yu Lin
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, 3663 N. Zhongshan Road, Shanghai, 200062, P. R. China
| | - Le-Yong Zhou
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, 3663 N. Zhongshan Road, Shanghai, 200062, P. R. China
| | - Lin Xu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, 3663 N. Zhongshan Road, Shanghai, 200062, P. R. China
| |
Collapse
|
41
|
Wang M, Jiang K, Gao Y, Liu Y, Zhang Z, Zhao W, Ji H, Zheng T, Feng H. A facile fabrication of conjugated fluorescent nanoparticles and micro-scale patterned encryption via high resolution inkjet printing. NANOSCALE 2021; 13:14337-14345. [PMID: 34473162 DOI: 10.1039/d1nr03062k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Conjugated fluorescent materials are getting more and more attention in the biomedical arena due to their high fluorescence intensity, non-bleaching and good biocompatibility. However, conjugated fluorescent materials are still not widely used in the field of anti-counterfeiting and pattern encryption due to their extremely low solubility and enormous difficulties in processing. Here, we use a facile approach to fabricate conjugated polymer fluorescent nanoparticles through a classic micro-emulsion method to address these issues. The particle size, loading materials and fluorescence intensity can be tuned as demanded. Later, these particles are transformed into invisible inks for inkjet printers to achieve micro-scale pattern encryption. These patterns show an ultra-high accuracy of around 30 micrometres. They can be used as QR codes for information encryption with 3 times more information encryption and great anti-counterfeiting ability. Finally, we establish an identification recognition system to check their validity. The scenario is the patient identification system of a hospital. The results show that these tags can be read in less than 3 seconds and they can last for 12 months at least. This facile approach holds great potential and bright prospects in the field of privacy protection, information encryption and anti-counterfeiting.
Collapse
Affiliation(s)
- Min Wang
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Kunkun Jiang
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Yifan Gao
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Yaming Liu
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Zhenchao Zhang
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Weiwei Zhao
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Hongjun Ji
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| | - Tingting Zheng
- Peking University Shenzhen Hospital & Biomedical Research Institute, Shenzhen-PKU-HKUST Medical Center, Shenzhen, 518036, China
| | - Huanhuan Feng
- Sauvage Laboratory for Smart Materials, Flexible Printed Electronic Technology Center, School of Materials Science and Engineering, Harbin Institute of Technology (Shenzhen), Shenzhen, 518055, China.
| |
Collapse
|
42
|
Xiang Y, Yan H, Zheng B, Faheem A, Guo A, Hu C, Hu Y. Light-Regulated Natural Fluorescence of the PCC 6803@ZIF-8 Composite as an Encoded Microsphere for the Detection of Multiple Biomarkers. ACS Sens 2021; 6:2574-2583. [PMID: 34156832 DOI: 10.1021/acssensors.1c00104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
The use of color-encoded microspheres for a bead-based assay has attracted increasing attention for high-throughput multiplexed bioassays. A fluorescent PCC 6803@ZIF-8 composite was prepared as a bead-based assay platform by a self-assembled zeolitic imidazolate framework (ZIF-8) on the surface of inactivated PCC 6803 cells. The composite fluorescence owing to the presence of pigment proteins in PCC 6803 could be gradually bleached with the prolongation of the ultraviolet light irradiation time. The composites with different fluorescence intensities were therefore obtained as encoded microspheres for the multiplexed assay. ZIF-8 provides a stable, rigid shell and a large specific surface area for composites, which prevent the composites from breakage during use and storage, simplify the protein immobilization procedure, reduce non-specific adsorption, and enhance the detection sensitivity. The encoded composites were successfully used to detect multiple DNA insertion sequences of Mycobacterium tuberculosis. The presented strategy offers an innovative color-encoding method for high-throughput multiplexed bioassays without the need of using chemically synthesized fluorescent materials.
Collapse
Affiliation(s)
- Yuqiang Xiang
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
| | - Huaduo Yan
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
| | - Bingjie Zheng
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
| | - Aroosha Faheem
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
| | - Aizhen Guo
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070, China
| | - Changmin Hu
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Veterinary Medicine, Huazhong Agricultural University, Wuhan 430070, China
| | - Yonggang Hu
- State Key Laboratory of Agricultural Microbiology, Huazhong Agricultural University, Wuhan 430070, China
- College of Life Science and Technology, Huazhong Agricultural University, Wuhan 430070, China
| |
Collapse
|
43
|
Wang J, Pinkse PWH, Segerink LI, Eijkel JCT. Bottom-Up Assembled Photonic Crystals for Structure-Enabled Label-Free Sensing. ACS NANO 2021; 15:9299-9327. [PMID: 34028246 PMCID: PMC8291770 DOI: 10.1021/acsnano.1c02495] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Accepted: 05/19/2021] [Indexed: 05/10/2023]
Abstract
Photonic crystals (PhCs) display photonic stop bands (PSBs) and at the edges of these PSBs transport light with reduced velocity, enabling the PhCs to confine and manipulate incident light with enhanced light-matter interaction. Intense research has been devoted to leveraging the optical properties of PhCs for the development of optical sensors for bioassays, diagnosis, and environmental monitoring. These applications have furthermore benefited from the inherently large surface area of PhCs, giving rise to high analyte adsorption and the wide range of options for structural variations of the PhCs leading to enhanced light-matter interaction. Here, we focus on bottom-up assembled PhCs and review the significant advances that have been made in their use as label-free sensors. We describe their potential for point-of-care devices and in the review include their structural design, constituent materials, fabrication strategy, and sensing working principles. We thereby classify them according to five sensing principles: sensing of refractive index variations, sensing by lattice spacing variations, enhanced fluorescence spectroscopy, surface-enhanced Raman spectroscopy, and configuration transitions.
Collapse
Affiliation(s)
- Juan Wang
- BIOS
Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical
Medical Centre & Max Planck Center for Complex Fluid Dynamics, University of Twente, 7522 NB Enschede, The Netherlands
| | - Pepijn W. H. Pinkse
- Complex
Photonic Systems Group, MESA+ Institute for Nanotechnology, University of Twente, 7522 NB Enschede, The Netherlands
| | - Loes I. Segerink
- BIOS
Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical
Medical Centre & Max Planck Center for Complex Fluid Dynamics, University of Twente, 7522 NB Enschede, The Netherlands
| | - Jan C. T. Eijkel
- BIOS
Lab on a Chip Group, MESA+ Institute for Nanotechnology, Technical
Medical Centre & Max Planck Center for Complex Fluid Dynamics, University of Twente, 7522 NB Enschede, The Netherlands
| |
Collapse
|
44
|
Xiang X, Ye Q, Shang Y, Li F, Zhou B, Shao Y, Wang C, Zhang J, Xue L, Chen M, Ding Y, Wu Q. Quantitative detection of aflatoxin B 1 using quantum dots-based immunoassay in a recyclable gravity-driven microfluidic chip. Biosens Bioelectron 2021; 190:113394. [PMID: 34118762 DOI: 10.1016/j.bios.2021.113394] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 05/25/2021] [Accepted: 05/31/2021] [Indexed: 12/29/2022]
Abstract
To achieve rapid and sensitive detection of aflatoxin B1 (AFB1), we developed a polydimethylsiloxane gravity-driven cyclic microfluidic chip using the two-signal mode strategy. The structural design of the chip, together with the two-wavelength quantum dot ratio fluorescence, effectively eliminates the influence of environmental factors, improves the signal stability, and ensures that the final detection result positively correlates with the target concentration. Moreover, the theoretical analysis performed for the established physical model of the three-dimensional reaction interface inside the chip confirmed the improved reaction rate of immune adsorption in the microfluidic strategy. Overall, the method exhibited a wide analytic range (0.2-500 ng mL-1), low detection limit (0.06 ng mL-1), high specificity, good precision (coefficient of variation < 5%), excellent reusability (20 times, 89.1%) and satisfactory practical sample analysis capacity. Furthermore, the reusability and designability of this chip provide a reliable scheme for field detection of AFB1, analysis of other small molecules, and establishment of high-throughput detection systems under different conditions.
Collapse
Affiliation(s)
- Xinran Xiang
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China
| | - Qinghua Ye
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China
| | - Yuting Shang
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China
| | - Fan Li
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China
| | - Baoqing Zhou
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China
| | - Yanna Shao
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; Department of Food Science and Technology, Jinan University, Guangzhou, China
| | - Chufang Wang
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China
| | - Jumei Zhang
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China
| | - Liang Xue
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China
| | - Moutong Chen
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China
| | - Yu Ding
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; Department of Food Science and Technology, Jinan University, Guangzhou, China.
| | - Qingping Wu
- Guangdong Provincial Key Laboratory of Microbial Safety and Health, State Key Laboratory of Applied Microbiology Southern China, Institute of Microbiology, Guangdong Academy of Sciences, Guangzhou, China; School of Biology and Biological Engineering, South China University of Technology, Guangzhou, China.
| |
Collapse
|
45
|
Berwanger JD, Tan HY, Jokhadze G, Bruening ML. Determination of the Serum Concentrations of the Monoclonal Antibodies Bevacizumab, Rituximab, and Panitumumab Using Porous Membranes Containing Immobilized Peptide Mimotopes. Anal Chem 2021; 93:7562-7570. [PMID: 33999602 DOI: 10.1021/acs.analchem.0c04903] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Effective monoclonal antibody (mAb) therapies require a threshold mAb concentration in patient serum. Moreover, the serum concentration of the mAb Bevacizumab should reside in a specific range to avoid side effects. Methods for conveniently determining the levels of mAbs in patient sera could allow for personalized dosage schedules that lead to more successful treatments. This work utilizes microporous nylon membranes functionalized with antibody-binding peptides to capture Bevacizumab, Rituximab, or Panitumumab from diluted (25%) serum. Modification of the capture-peptide terminus is often crucial to creating the affinity necessary for effective binding. The high purity of eluted mAbs allows for their quantitation using native fluorescence, and membranes are effective in spin devices that can be used in any laboratory. The technique is effective over the therapeutic range of Bevacizumab concentrations. Future work aims at further modifications to develop rapid point-of-care devices and decrease detection limits.
Collapse
Affiliation(s)
- Joshua D Berwanger
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Hui Yin Tan
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Gia Jokhadze
- Takara Bio USA, Inc., Mountain View, California 94043, United States
| | - Merlin L Bruening
- Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana 46556, United States.,Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, United States
| |
Collapse
|
46
|
Hou M, Shi L, Zhou Y, Wang J, Jiang J, Jiang J, He J. Expanding the codes: The development of density-encoded hydrogel microcarriers for suspension arrays. Biosens Bioelectron 2021; 181:113133. [PMID: 33744669 DOI: 10.1016/j.bios.2021.113133] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 02/05/2021] [Accepted: 02/27/2021] [Indexed: 12/26/2022]
Abstract
Although suspension array technology (SAT), which uses encoded microspheres, provides high-quality results with versatile applicability for information-intensive bioanalytic applications, current encoding strategies limit the number of codes that can be distinguished. In this paper, we introduce density-encoded hydrogel microcarriers (DMs), which employ the intrinsic density property of biomaterials as a high-capacity coding dimension. Two hydrogel monomers were employed at different ratios to synthesize microgels with distinctive densities. DMs not only can be simultaneously decoded and separated using density gradient centrifugation, but also are compatible with flow cytometry detection. The size and color of DMs have been used as extra coding parameters, to construct an 8 × 2 × 4 (density × size × color) three-dimensionally encoded hydrogel microcarrier library. With aptamer-functionalized DMs (ADMs), we developed a 4-plex protein quantification method for the label-free detection of plasma biomarkers with sub-nanomolar detection limits and good linearities. Moreover, ADMs can be used for label-free naked-eye detection of tumor-derived exosomes. We believe that the simplicity and functionality of DMs will advance the field of suspension arrays and inspire the development of DM-based diagnostic applications.
Collapse
Affiliation(s)
- Min Hou
- College of Biology, Hunan University, Changsha, 410082, China
| | - Liyang Shi
- College of Biology, Hunan University, Changsha, 410082, China
| | - Yancen Zhou
- College of Biology, Hunan University, Changsha, 410082, China
| | - Jiao Wang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China
| | - Jiali Jiang
- College of Biology, Hunan University, Changsha, 410082, China
| | - Jianhui Jiang
- State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China.
| | - Jianjun He
- College of Biology, Hunan University, Changsha, 410082, China.
| |
Collapse
|
47
|
Li CY, Zheng B, Li JT, Gao JL, Liu YH, Pang DW, Tang HW. Holographic Optical Tweezers and Boosting Upconversion Luminescent Resonance Energy Transfer Combined Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)/Cas12a Biosensors. ACS NANO 2021; 15:8142-8154. [PMID: 33428399 DOI: 10.1021/acsnano.0c09986] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Taking advantage of outstanding precision in target recognition and trans-cleavage ability, the recently discovered CRISPR/Cas12a system provides an alternative opportunity for designing fluorescence biosensors. To fully exploit the analytical potential, we introduce here some meaningful concepts. First, the collateral cleavage of CRISPR/Cas12a is efficiently activated in a functional DNA regulation manner and the bottleneck which largely applicable to nucleic acids detection is broken. After selection of a representative aptamer and DNAzyme as the transduction pathways, the sensing coverage is extended to a small organic compound (ATP) and a metal ion (Na+). The assay sensitivity is significantly improved by utilizing a bead-supported enrichment strategy wherein emerging holographic optical tweezers are used to enhance imaging stability and simultaneously achieve multiflux analysis. Last, a sandwich-structured energy-concentrating upconversion nanoparticle triggered boosting luminescent resonance energy transfer mode is comined to face with complicated biological samples by skillfully confining the emitters into a very limited inner shell. Following the above attempts, the developed CRISPR/Cas12a biosensors not only present an ultrasensitive assay behavior toward these model non-nucleic acid analytes but also can serve as a formidable toolbox for determining real samples including single cell lysates and human plasma, proving a good practical application capacity.
Collapse
Affiliation(s)
- Cheng-Yu Li
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Bei Zheng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| | - Jiang-Tao Li
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| | - Jia-Ling Gao
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Yu-Heng Liu
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan, 430065, People's Republic of China
| | - Dai-Wen Pang
- State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Sciences, and College of Chemistry, Nankai University, Tianjin 300071, People's Republic of China
| | - Hong-Wu Tang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, 430072, People's Republic of China
| |
Collapse
|
48
|
Masoomi H, Wang Y, Chen C, Zhang J, Ge Y, Guo Q, Gu H, Xu H. A facile polymer mediated dye incorporation method for fluorescence encoded microbeads with large encoding capacities. Chem Commun (Camb) 2021; 57:4548-4551. [PMID: 33956007 DOI: 10.1039/d0cc08202c] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Here we report a facile dye incorporation method for fluorescence encoded microbeads, which is achieved by tuning the mixed polymer type (blank and dye-labeled polymers) and their doping ratio through electrostatic loading into mesoporous beads. This method is universal to various carriers and could render large encoding capacities.
Collapse
Affiliation(s)
- Hajar Masoomi
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Yao Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Cang Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Jiayu Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Yunfei Ge
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Qingsheng Guo
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Hongchen Gu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| | - Hong Xu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China.
| |
Collapse
|
49
|
Wang Y, Chen C, He J, Cao Y, Fang X, Chi X, Yi J, Wu J, Guo Q, Masoomi H, Wu C, Ye J, Gu H, Xu H. Precisely Encoded Barcodes through the Structure-Fluorescence Combinational Strategy: A Flexible, Robust, and Versatile Multiplexed Biodetection Platform with Ultrahigh Encoding Capacities. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2100315. [PMID: 33817970 DOI: 10.1002/smll.202100315] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 02/12/2021] [Indexed: 06/12/2023]
Abstract
With the rapid development of suspension array technology, microbeads-based barcodes as the core element with sufficient encoding capacity are urgently required for high-throughput multiplexed detection. Here, a novel structure-fluorescence combinational encoding strategy is proposed for the first time to establish a barcode library with ultrahigh encoding capacities. Based on the never revealed transformability of the structural parameters (e.g., porosity and matrix component) of mesoporous microbeads into scattering signals in flow cytometry, the enlargement of codes number has been successfully realized in combination with two other fluorescent elements of fluorescein isothiocyanate isomer I (FITC) and quantum dots (QDs). The barcodes are constructed with precise architectures including FITC encapsulated within mesopores and magnetic nanoparticles as well as QDs immobilized on the outer surface to achieve the ultrahigh encoding level of 300 accompanied with superparamagnetism. To the best of knowledge, it is the highest record of single excitation laser-based encoding capacity up to now. Moreover, a ten-plexed tumor markers bioassay based on the tailored-designed barcodes has been evaluated to confirm their feasibility and effectiveness, and the results indicate that the barcodes platform is a promising and robust tool for practical multiplexed biodetection.
Collapse
Affiliation(s)
- Yao Wang
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Cang Chen
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Jing He
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Yimei Cao
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Xiaoxia Fang
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Xiaomei Chi
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Jingwei Yi
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Jiancong Wu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Qingsheng Guo
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Hajar Masoomi
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Chongzhao Wu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Jian Ye
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Hongchen Gu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| | - Hong Xu
- Shanghai Jiao Tong University Affiliated Sixth People's Hospital, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China
| |
Collapse
|
50
|
He X, Jia K, Bai Y, Chen Z, Liu Y, Huang Y, Liu X. Quantum dots encoded white-emitting polymeric superparticles for simultaneous detection of multiple heavy metal ions. JOURNAL OF HAZARDOUS MATERIALS 2021; 405:124263. [PMID: 33535353 DOI: 10.1016/j.jhazmat.2020.124263] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/26/2020] [Accepted: 10/09/2020] [Indexed: 06/12/2023]
Abstract
Simultaneous detection of multiple heavy metal ions (HMI) is of great importance for the environmental monitoring, and the analytical tools based on multiband emissive fluorescent probes have been regarded as one of the most promising candidate for multiple HMI detection. Herein, the rod-coil amphiphilic block copolymer (BCP) with intrinsic blue fluorescence emission has been synthesized and subsequently employed to encapsulate two types of hydrophobic quantum dots (QD) with green and red fluorescence emission via the three dimensionally confined emulsion self-assembly, leading to the generation of white-emitting superparticles showing good colloidal stability and stable aqueous phase fluorescence. Furthermore, it was found that the fluorescence emission intensity of obtained superparticles can be selectively quenched by Ag+, Hg2+, Cu2+ and Fe3+ ions via different mechanisms, and the four metal ions can be further discriminated according to their distinct combinational quenching effects onto three fluorescent bands of white-emitting superparticles. In addition, an analytical model was built to enable the simultaneous detection of Cu2+, Hg2+ and Fe3+ in the real sample. Basically, the current work opens the new way to fabricate fluorescent probes with multiple emission bands, which can be easily adapted to prepare more complicated QD encoded fluorescent probes for high throughput detection.
Collapse
Affiliation(s)
- Xiaohong He
- School of Materials and Energy, University of Electronic Science and Technology of China, 611731 Chengdu, PR China
| | - Kun Jia
- School of Materials and Energy, University of Electronic Science and Technology of China, 611731 Chengdu, PR China.
| | - Yun Bai
- School of Materials and Energy, University of Electronic Science and Technology of China, 611731 Chengdu, PR China
| | - Zhongyuan Chen
- Department of Biophysics, School of Life Science and Technology, University of Electronic Science and Technology of China, 610054 Chengdu, PR China
| | - Yiyao Liu
- Department of Biophysics, School of Life Science and Technology, University of Electronic Science and Technology of China, 610054 Chengdu, PR China
| | - Yumin Huang
- School of Materials and Energy, University of Electronic Science and Technology of China, 611731 Chengdu, PR China
| | - Xiaobo Liu
- School of Materials and Energy, University of Electronic Science and Technology of China, 611731 Chengdu, PR China
| |
Collapse
|