de Oliveira LH, Trindade MAG, Angnes L. Chronoamperometric flow-cell designed to be unaffected by air bubbles. Talanta 2025; 281:126875. [PMID: 39298807 DOI: 10.1016/j.talanta.2024.126875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 08/28/2024] [Accepted: 09/10/2024] [Indexed: 09/22/2024]
Abstract
In this paper, we present a new design for a chronoamperometric flow cell in which air bubbles do not interfere with the control of potential between the working and reference electrodes. The flow-through dual-detection cell consists of two independent parts: an upper compartment containing a quiescent supporting electrolyte solution and a channel that operates under hydrodynamically controlled conditions. In this system, the working and counter electrodes can be placed directly in contact with both compartments, whereas the reference electrode can be assembled to be either isolated or in contact with the flowing stream channel. The design ensures that the potential applied to the working electrode (controlled in the upper compartment) is similar to the potential applied in the flowing channel. The performance of the proposed flow cell in generating accurate results, even in the presence of air bubbles, was evaluated through successive air-analyte-air injections. In both series where the analyte was introduced, suitable reproducibility was achieved. The robustness of the design was definitively proven by performing a series of measurements in analytical applications for the determination of hydrogen peroxide in antiseptic samples, yielding very satisfactory results.
Collapse
Affiliation(s)
- Luiz Henrique de Oliveira
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, 79804-970, Dourados, MS, Brazil; Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748 - 05508-000, São Paulo, SP, Brazil
| | - Magno Aparecido Gonçalves Trindade
- Faculdade de Ciências Exatas e Tecnologia, Universidade Federal da Grande Dourados, Rodovia Dourados-Itahum, km 12, 79804-970, Dourados, MS, Brazil; UNESP, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, P.O. Box 355, 14800-900, Araraquara, SP, Brazil.
| | - Lucio Angnes
- Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748 - 05508-000, São Paulo, SP, Brazil.
| |
Collapse
|
2
|
Skok A, Manousi N, Anthemidis A, Bazel Y. Automated Systems with Fluorescence Detection for Metal Determination: A Review. Molecules 2024; 29:5720. [PMID: 39683879 DOI: 10.3390/molecules29235720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2024] [Revised: 12/01/2024] [Accepted: 12/02/2024] [Indexed: 12/18/2024] Open
Abstract
Industrialization has led to environmental pollution with various hazardous chemicals including pollution with metals. In this regard, the development of highly efficient analytical methods for their determination has received considerable attention to ensure public safety. Currently, scientists are paying more and more attention to the automation of analytical methods, since it permits fast, accurate, and sensitive analysis with minimal exposure of analysts to hazardous substances. This review discusses the automated methods with fluorescent detection developed for metal determination since 2000. It is evident that flow-injection analysis (FIA) with no preconcentration or with solid-phase preconcentration are predominant compared to liquid-phase preconcentration systems. FIA systems are also more widespread than sequential injection analysis (SIA) systems. Moreover, a significant number of works have been devoted to chromatography-based methods. Atomic fluorescence detectors significantly prevail over molecular fluorescence detectors. It must be highlighted that most of the methods result in good figures of merit and performance characteristics, demonstrating their superiority in comparison with manual systems.
Collapse
Affiliation(s)
- Arina Skok
- Department of Analytical Chemistry, Institute of Chemistry, Faculty of Science, Pavol Jozef Safarik University in Kosice, Moyzesova 11, 040 01 Kosice, Slovakia
| | - Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Aristidis Anthemidis
- Laboratory of Analytical Chemistry, School of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - Yaroslav Bazel
- Department of Analytical Chemistry, Institute of Chemistry, Faculty of Science, Pavol Jozef Safarik University in Kosice, Moyzesova 11, 040 01 Kosice, Slovakia
| |
Collapse
|
3
|
Barros VAF, Zagatto EAG. Relevant insights and concepts overlooked throughout the development of flow analysis. A tutorial. Talanta 2024; 280:126689. [PMID: 39153255 DOI: 10.1016/j.talanta.2024.126689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 07/26/2024] [Accepted: 08/06/2024] [Indexed: 08/19/2024]
Abstract
The conceptual expansion, fast development, and general acceptance of flow analysis are consequence of its adherence to the principles of green and white analytical chemistry, and chemical derivatization plays an essential role in this context. Through the flow analysis development, however, some of its potentialities and limitations have been overlooked. This is more evident when the involved modifications in flow rates, timing and/or manifold architecture deteriorate the analytical signals. These aspects have not always been systematically investigated, and are addressed here in relation to flow analyzers with UV-Vis spectrophotometric detection. Novel strategies for solution handling, guidance for dealing with the aforementioned analytical signal deterioration, and an alternative possibility for exploiting differential aspiration are presented. The concept of blank reagent carrier stream is proposed.
Collapse
Affiliation(s)
- Valdemir A F Barros
- Centre for Nuclear Energy in Agriculture, University of Sao Paulo, P.O. Box 96, Piracicaba, 13400-970, Brazil
| | - Elias A G Zagatto
- Centre for Nuclear Energy in Agriculture, University of Sao Paulo, P.O. Box 96, Piracicaba, 13400-970, Brazil.
| |
Collapse
|
4
|
Ma Y, Sella C, Thouin L. Electrochemiluminescence in Microfluidic Channels: Influence of Mass Transport on the Tris(2,2'-bipyridyl)ruthenium(II)/Tripropylamine System at Semitransparent Electrodes. Anal Chem 2024; 96:14650-14659. [PMID: 39180508 DOI: 10.1021/acs.analchem.4c03344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/26/2024]
Abstract
Mass transport in laminar flow can improve the electrochemiluminescence (ECL) performance at the microchannel electrodes, depending on the device geometry and operating regimes. The known Ru(bpy)32+/tripropylamine (TPA) system was selected and studied in continuous microfluidics on semitransparent platinum electrodes. With this electrode material, ECL is mainly generated via a catalytic pathway. This mechanism was characterized under flow conditions by monitoring the ECL emission using linear sweep voltammetry and chronoamperometry. In parallel, ECL imaging of the electrode surface was conducted in order to characterize the ECL profiles above the electrode in the flow direction. Numerical simulations were carried out and then compared to experimental data to both confirm the ECL mechanism and assess the main kinetic parameters. A good agreement was obtained, demonstrating the influence of the operating regimes of the microchannel electrodes on the ECL performances. In the thin-layer regime, due to TPA depletion, ECL is located at the upstream edge of the electrode, while it is homogeneously distributed over the electrode surface in convective regimes. These characteristics will necessarily have to be taken into account in the design of dedicated ECL analytical microfluidic devices operating under continuous flow.
Collapse
Affiliation(s)
- Yumeng Ma
- PASTEUR, Département de chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Catherine Sella
- PASTEUR, Département de chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| | - Laurent Thouin
- PASTEUR, Département de chimie, Ecole Normale Supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France
| |
Collapse
|
5
|
Khumngern S, Nontipichet N, Thavarungkul P, Kanatharana P, Numnuam A. Smartphone-enabled flow injection amperometric glucose monitoring based on a screen-printed carbon electrode modified with PEDOT@PB and a GOx@PPtNPs@MWCNTs nanocomposite. Talanta 2024; 277:126336. [PMID: 38823326 DOI: 10.1016/j.talanta.2024.126336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 04/25/2024] [Accepted: 05/29/2024] [Indexed: 06/03/2024]
Abstract
This study presents a modified screen-printed carbon electrode (SPCE) to determine glucose in a custom-built flow injection system. The biosensor was constructed by immobilizing glucose oxidase on porous platinum nanoparticles decorated on multi-walled carbon nanotubes (GOx@PPtNPs@MWCTNs). The fabrication of the biosensor was completed by coating the GOx@PPtNPs@MWCTNs nanocomposite on an SPCE modified with a nanocomposite of poly(3,4-ethylenedioxythiophene) and Prussian blue (GOx@PPtNPs@MWCTNs/PEDOT@PB/SPCE). The fabricated electrode accurately measured hydrogen peroxide (H2O2), the byproduct of the GOx-catalyzed oxidation of glucose, and was then applied as a glucose biosensor. The glucose response was amperometrically determined from the PB-mediated reduction of H2O2 at an applied potential of -0.10 V in a flow injection system. Under optimal conditions, the developed biosensor produced a linear range from 2.50 μM to 1.250 mM, a limit of detection of 2.50 μM, operational stability over 500 sample injections, and good selectivity. The proposed biosensor determined glucose in human plasma samples, achieving recoveries and results that agreed with the hexokinase-spectrophotometric method (P > 0.05). Combining the proposed biosensor with the custom-built sample feed, a portable potentiostat and a smartphone, enabled on-site glucose monitoring.
Collapse
Affiliation(s)
- Suntisak Khumngern
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Natha Nontipichet
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand
| | - Apon Numnuam
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand.
| |
Collapse
|
6
|
Jakkrawhad C, Makkliang F, Nurerk P, Siaj M, Poorahong S. Iron-based metal-organic framework/graphene oxide composite electrodes for efficient flow-injection amperometric detection of dexamethasone. RSC Adv 2024; 14:23921-23929. [PMID: 39086520 PMCID: PMC11289712 DOI: 10.1039/d4ra03815k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 07/22/2024] [Indexed: 08/02/2024] Open
Abstract
A highly stable flow-injection amperometric sensor for dexamethasone (DEX) was developed using a pencil graphite electrode (PGE) modified with Fe-based metal organic frameworks, MIL-100(Fe) and graphene oxide composite materials (MIL-100(Fe)/GO). Scanning electron microscopy and energy-dispersive X-ray spectroscopy, transmission electron microscopy, powder X-ray diffraction, and Fourier-transform infrared spectroscopy were used to characterize the MIL-100(Fe) composites. The MIL-100(Fe)/GO-modified PGE (denoted MIL-100(Fe)/GO/PGE) was further electrochemically characterized using cyclic voltammetry. As an electrode material, MIL-100(Fe) is a sensing element that undergoes oxidation from Fe(ii)-MOF to Fe(iii)-MOF, and GO possesses high conductivity and a large surface area, which exhibits high absorbability. In the presence of DEX, Fe(iii) is reduced, which accelerates electron transfer at the electrode interface. Therefore, DEX can be quantitatively detected by analyzing the anodic current of MIL-100(Fe). When coupled with amperometric flow injection analysis, excellent performance can be obtained even when a low detection potential is applied (+0.10 V vs. Ag/AgCl). The concentration was linear in the range 0.10-5.0 μM and 0.010-5.0 mM with LOD of 0.030 μM based on 3(sd/slope). The modified electrode also exhibited a remarkably stable response under optimized conditions, and up to 55 injections can be used per electrode. The sensor exhibits high repeatability, reproducibility, and anti-interference properties when used for DEX detection. The effective determination of dexamethasone in real pharmaceutical and cosmetic samples demonstrated the feasibility of the electrochemical sensor, and the results were in good agreement with those obtained from the HPLC-DAD analysis. Acceptable percentage recoveries from the spiked pharmaceutical and cosmetic samples were obtained, ranging from 93-111% for this new method compared with 84-107% for the HPLC-DAD standard method.
Collapse
Affiliation(s)
- Chanida Jakkrawhad
- Functional Materials and Nanotechnology Center of Excellence, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
- Department of Chemistry, School of Science, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
| | - Fonthip Makkliang
- Functional Materials and Nanotechnology Center of Excellence, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
- School of Languages and General Education, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
| | - Piyaluk Nurerk
- Functional Materials and Nanotechnology Center of Excellence, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
- Department of Chemistry, School of Science, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
| | - Mohamed Siaj
- Department of Chemistry, Université du Québec à Montréal Montréal Québec H3C 3P8 Canada
| | - Sujittra Poorahong
- Functional Materials and Nanotechnology Center of Excellence, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
- Department of Chemistry, School of Science, Walailak University Thasala Nakhon Si Thammarat 80160 Thailand
| |
Collapse
|
7
|
Derayea SM, Zaafan AAS, Nagy DM, Oraby M. Development and validation of a precise flow injection method for the assessment of brexpiprazole, with application to pharmaceutical dosage forms and human plasma analysis. BMC Chem 2024; 18:137. [PMID: 39061082 PMCID: PMC11282860 DOI: 10.1186/s13065-024-01240-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 07/04/2024] [Indexed: 07/28/2024] Open
Abstract
A novel antipsychotic medication named brexpiprazole (BRX) is currently employed for the treatment of schizophrenia and other psychotic disorders. Because BRX's molecular structure includes a benzothiophene ring, it natively fluoresces. To detect BRX with precision and speed, a flow injection-fluorometric method, which is both sensitive and selective, is recommended. The fluorescence detection was conducted at 364 nm following excitation at 326 nm to capture the strong intrinsic fluorescence of BRX. The carrier solution employed was a mixture of phosphate buffer (pH 4, 10 mM) and acetonitrile (50: 50, v/v), with a flow rate of 0.5 mL min- 1. The calibration curve, based on peak areas, exhibited linearity within the concentration range of 20-350 ng mL- 1, with a remarkable correlation coefficient (r2) of 0.9999. The limit of quantitation was 9.7 ng mL- 1, and the limit of detection was found to be 3.2 ng mL- 1. This method was applied to quantify BRX in Neopression® tablets, achieving recovery within an acceptable range without interference from the tablet's additives. Additionally, the proposed approach was successfully utilised to quantify the drug in spiked human plasma. The approach underwent validation following ICH requirements.
Collapse
Affiliation(s)
- Sayed M Derayea
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, 61519, Egypt
| | - Al Amir S Zaafan
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, Sohag, 82524, Egypt.
| | - Dalia M Nagy
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, 61519, Egypt
| | - Mohamed Oraby
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Sohag University, Sohag, 82524, Egypt
| |
Collapse
|
8
|
Abdullah NS, Hassan MA, Hassan RO. A Novel Flow Injection Method with Chemiluminescence Detection for the Determination of Carmoisine in Gelatin Desserts. J Fluoresc 2024:10.1007/s10895-024-03777-8. [PMID: 38780834 DOI: 10.1007/s10895-024-03777-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Accepted: 05/16/2024] [Indexed: 05/25/2024]
Abstract
Carmoisine dye, a red azo food colorant commonly utilized to impart a red color to synthetic food products, is the subject of this study. Here, we present a novel reversed flow injection analysis with a chemiluminescence detection (FIA-CL) method employing a newly developed homemade flow cell to determine carmoisine dye. This developed method is based on the inhibition effect of the dye on the chemiluminescence light (CL) emission generated from a luminal-hypochlorite system, whereby the reduction in CL intensity correlates directly with the concentration of carmoisine dye. Investigations into various analytical parameters were conducted to enhance method efficiency and applicability. A linear calibration graph of 4.0 to 100.0 µg mL-1 was established (R² = 0.9993), with a detection limit of LOD = 2.93 µg mL-1. Subsequent application of the proposed method to analyze gelatine dessert samples yielded results in reasonable agreement with those obtained using the reported HPLC method, as evidenced by student t-test and F-test analyses.
Collapse
Affiliation(s)
- Narmin S Abdullah
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq
| | - Media A Hassan
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq
| | - Rebwar O Hassan
- Chemistry Department- Science College, Salahaddin University-Erbil, Erbil, Kurdistan Region, Iraq.
- Department of Radiological Imaging Technology, College of Health Technology Cihan University-Erbil, Erbil, Kurdistan Region, Iraq.
| |
Collapse
|
9
|
Maringolo V, Carvalho AZ, Rocha DL. Simple multi-signal calibrations exploiting flow analysis systems. Talanta 2024; 272:125787. [PMID: 38401267 DOI: 10.1016/j.talanta.2024.125787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 02/08/2024] [Accepted: 02/12/2024] [Indexed: 02/26/2024]
Abstract
Multi-signal calibrations have been recently exploited in molecular spectrochemical analysis alternatively to traditional calibration methods, improving analytical frequency and accuracy. The application of these strategies is simple and minimizes efficiently matrix effects by analyzing two calibration solutions comprising sample plus standard (S1), and sample plus blank (S2). The plot of the signals obtained with S1 and S2 at multiple settings (e.g. different wavelengths) yield a slope that can be related to the analyte concentration in the sample. Similarly, transient signals could also be related to the analyte concentration exploiting a similar strategy. Thus, in this work, two multi-signal approaches developed in flow-based systems are proposed, based on the responses at multiple wavelengths (online multi-energy calibration, OMEC), and on the dispersion profile of the samples, herein denominated multi-dispersion calibration (MDC). The calibrations were carried out with sample solutions after 2-fold dilution with a standard solution and with water. The feasibility of OMEC and MDC were demonstrated using KMnO4 solutions (without chemical reactions) under continuous and pulsed flow regimes. The applicability of this strategy was also demonstrated by the spectrophotometric determination of urea in milk and pet potty spray in a multi-pumping flow system, based on the color change of bromothymol blue after catalyzed hydrolysis by urease from jack beans (Canavalia ensiformis). MDC and OMEC were compared with external calibrations (EC) and classical standard addition. The limits of detection for urea were estimated at 13 mg L-1, 16 mg L-1, and 10 mg L-1 using MDC, MEC and EC, respectively. Recoveries from 93 to 101%, and the agreement of sample analyzes with the reference procedure demonstrated the good accuracy achieved by the proposed methods. Therefore, it was demonstrated the feasibility of MDC and OMEC for analytical purposes in a simple and efficient way with the advantages of flow-based manifolds.
Collapse
Affiliation(s)
- Vivian Maringolo
- Center on Natural and Human Sciences, Federal University of ABC, 09210-580, Santo André, SP, Brazil.
| | - Alexandre Z Carvalho
- Center on Natural and Human Sciences, Federal University of ABC, 09210-580, Santo André, SP, Brazil
| | - Diogo L Rocha
- Center on Natural and Human Sciences, Federal University of ABC, 09210-580, Santo André, SP, Brazil.
| |
Collapse
|
10
|
Rodríguez-Maese R, Cerdà V, Leal LO. An overview of automated flow systems for total and isotopic analysis of strontium and yttrium in samples of environmental interest. Talanta 2024; 270:125643. [PMID: 38199120 DOI: 10.1016/j.talanta.2024.125643] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 12/27/2023] [Accepted: 01/06/2024] [Indexed: 01/12/2024]
Abstract
Due to the different uses of radioactivity during the last decades, there has been an increase in the concentration of natural and artificial radionuclides in the environment. This, along with some accidents with a high affect public opinion (for example, Chernobyl and Fukushima), have led to the growth and establishment of environmental radioactivity monitoring programs. Currently, trends in legislation and research are focused on the development of accurate, precise, reliable and fast analytical methods with low limits of detection (LOD) for radionuclides determination, such as strontium and yttrium, in environmental samples. In this paper, two comprehensive reviews and four automated analytical systems for total and isotopic determination of yttrium and strontium are presented. The developed methods have been applied in the analysis of environmental samples with low concentrations of these analytes. These methodologies have been automated by exploiting flow analysis techniques, such as multi-syringe flow injection analysis (MSFIA), Sequential injection analysis (SIA) and laboratory-on-valve (LOV) systems, achieving a minimal handling and low consumption of samples and reagents, a significant reduction in waste generation and a high frequency of analysis. In the developed methodologies, some spectrometric methods such as ICP-OES and ICP-MS have been implemented as detection techniques instead of radiometric detectors obtaining a fully automated, low-cost and fast yttrium and strontium determinations.
Collapse
Affiliation(s)
- Rogelio Rodríguez-Maese
- Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Av. Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua, Chih, C.P. 31136, Mexico
| | - Víctor Cerdà
- Department of Chemistry, University of the Balearic Islands, 07122, Palma de Mallorca, Spain; Sciware Systems, S.L. 07193, Bunyola, Spain.
| | - Luz O Leal
- Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Av. Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua, Chih, C.P. 31136, Mexico
| |
Collapse
|
11
|
Al-Jaf SH, Omer KM. Dual-spot ratiometric microfluidic paper-based analytical device for accuracy and precision improvement. Talanta 2024; 269:125433. [PMID: 38008019 DOI: 10.1016/j.talanta.2023.125433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 11/09/2023] [Accepted: 11/16/2023] [Indexed: 11/28/2023]
Abstract
Instrumental and environmental fluctuations are common sources of error in smartphone-based optical detection, significantly affecting the accuracy of analytical measurements. In this regard, spotting the sample and reference simultaneously and in close proximity compensates for the fluctuations. This "dual-spot" design is similar to the double-beam technique used in spectrophotometry, which reduces fluctuations in the results. The underlying hypothesis is that any instrumental and/or environmental factors influencing the color intensity in the detection zones will similarly impact the color intensity in the control zone under the same conditions. To test our design, a ratiometric microfluidic paper-based analytical device (μPAD), functionalized with a mixture of green-emissive carbon dots (CDs) and red-emissive ethidium bromide, was developed for the selective detection of ascorbic acid (AA). The green emission of the CDs is quenched by both AA and Fe3+; NaF was thus loaded onto the 3D connector as a masking agent to remove the interference effect of the Fe3+ ions. The color variations were monitored under a UV lamp, using a smartphone to capture the images, and the RGB intensities were processed using the Color Grab application. The proposed double-spot method greatly enhanced the analytical precision and accuracy of the device. A linear working range from 0 to 125 μM was obtained, and the limit of detection was 2.71 μM. The μPAD was successfully used for the detection of AA in human serum, with recoveries from 87.27 to 98.52 %.
Collapse
Affiliation(s)
- Sabah H Al-Jaf
- Department of Chemistry, College of Science, University of Sulaimani, 46002, Sulaimani City, Kurdistan Region, Iraq; Department of Chemistry, College of Science, University of Garmian, Darbandikhan Road, 46021, Kalar City, Sulaimaniyah Province, Kurdistan of Iraq, Iraq
| | - Khalid M Omer
- Department of Chemistry, College of Science, University of Sulaimani, 46002, Sulaimani City, Kurdistan Region, Iraq.
| |
Collapse
|
12
|
Al Samarrai SY, AlZubaidi R, Al-Ansari N. Charge transfer complex-based spectrophotometric analysis of famotidine in pure and pharmaceutical dosage forms. Sci Rep 2024; 14:3661. [PMID: 38351288 PMCID: PMC10864395 DOI: 10.1038/s41598-024-54402-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 02/12/2024] [Indexed: 02/16/2024] Open
Abstract
A straightforward and efficient spectrum technique was created using Ortho-chloranil as the electron acceptor (-acceptor) in a charge transfer (CT) complex formation reaction to determine the concentration of famotidine (FMD) in solutions. Compared to the double-distilled blank solution, the reaction result detected a definite violet colour at a maximum absorption wavelength of 546 nm, For concentrations range 2-28 µg/ml, the technique demonstrated excellent compliance with Beer-Law and Lambert's, as evidenced by its molar absorptivity of 2159.648 L mol-1 cm-1. Lower detection limits of 0.3024 µg/ml and 1.471 µg/ml, respectively, were discovered. The complexes of famotidine and Ortho-chloranil were found to have a 2:1 stoichiometry. Additionally, the suggested approach effectively estimated famotidine concentrations in pharmaceutical formulations, particularly in tablet form.
Collapse
Affiliation(s)
| | - Radhi AlZubaidi
- Civil and Environmental Engineering, College of Engineering, University of Sharjah, Sharjah, United Arab Emirates
| | - Nadhir Al-Ansari
- Department of Civil, Environmental and Natural Resources Engineering, Lulea University of Technology, Luleå, Sweden.
| |
Collapse
|
13
|
Falih MS, Abbas RF, Mahdi NI, Abood NK, Hassan MJM. FIA- spectrophotometric method for the determination of amoxicillin in pharmaceuticals; application of AES, GAPI, and AGREE greenness assessment tools. MethodsX 2023; 11:102437. [PMID: 37928107 PMCID: PMC10622687 DOI: 10.1016/j.mex.2023.102437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 10/11/2023] [Indexed: 11/07/2023] Open
Abstract
A new, simple, and sensitive FIA-spectrophotometric method has been developed for evaluating pure amoxicillin and pharmaceutical formulations. The FIA method involves the reaction of dapsone with sodium nitrite and hydrochloric acid. Subsequently, the diazotized dapsone is coupled with amoxicillin in an alkaline medium, resulting in a stable orange dye with a maximum wavelength of 440 nm. The developed method was validated according to the ICH guidelines and found to have a concentration range of 1-150 µg/mL, a correlation coefficient of 0.9994, a molar extinction coefficient of 0.273 × 104 L/mol.cm, and a detection limit of 0.074 µg/mL. The FIA method was then evaluated using AES, GAPI, and AGREES analytical greenness assessment tools. The FIA method uses dapsone as an eco-friendly reagent, in addition to the FIA method's advantages of reduced sample and reagent usage, reduced waste generation, and cheaper equipment. So, it has been proposed as an excellent eco-friendly method for the determination of AMX in pharmaceutical formulations.
Collapse
Affiliation(s)
- Marwa sabbar Falih
- Department of Chemistry, College of Science, Mustansiriyah University, Baghdad, Iraq
| | - Ruba Fahmi Abbas
- Department of Chemistry, College of Science, Mustansiriyah University, Baghdad, Iraq
| | - Neda Ibrahim Mahdi
- Department of Chemistry, College of Science, Mustansiriyah University, Baghdad, Iraq
| | - Nisreen Kais Abood
- Department of Chemistry, College of Science, Mustansiriyah University, Baghdad, Iraq
| | | |
Collapse
|
14
|
Samadifar M, Yamini Y, Khataei MM, Shirani M. Automated and semi-automated packed sorbent solid phase (micro) extraction methods for extraction of organic and inorganic pollutants. J Chromatogr A 2023; 1706:464227. [PMID: 37506462 DOI: 10.1016/j.chroma.2023.464227] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Revised: 07/06/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In this study, the packed sorbent solid phase (micro) extraction methods from manual to automated modes are reviewed. The automatic methods have several remarkable advantages such as high sample throughput, reproducibility, sensitivity, and extraction efficiency. These methods include solid-phase extraction, pipette tip micro-solid phase extraction, microextraction by packed sorbent, in-tip solid phase microextraction, in-tube solid phase microextraction, lab-on-a-chip, and lab-on-a-valve. The recent application of these methods for the extraction of organic and inorganic compounds are discussed. Also, the combination of novel technologies (3D printing and robotic platforms) with the (semi)automated methods are investigated as the future trend.
Collapse
Affiliation(s)
- Mahsa Samadifar
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran.
| | | | - Mahboue Shirani
- Department of Chemistry, Faculty of Sciences, University of Jiroft, Jiroft, Iran
| |
Collapse
|
15
|
Chen X, Zhang M, Li X, Xu J, Liang Y. Ammonium determination by merging-zone flow injection analysis and a naphthalene-based fluorescent probe. Talanta 2023; 256:124274. [PMID: 36681040 DOI: 10.1016/j.talanta.2023.124274] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Revised: 01/12/2023] [Accepted: 01/14/2023] [Indexed: 01/17/2023]
Abstract
This paper discusses the first-time study of a naphthalene-based fluorescent probe-naphthalene-2,3-dicarboxaldehyde (NDA), in combination with merging-zone flow injection analysis for the automated fluorescence determination of ammonium. The determination was contingent on detecting the fluorescent product of NDA-SO32--NH4+, which has maximum excitation and emission wavelengths of 508 nm and 564 nm, respectively. And the possible sensing mechanism of NDA-NH4+ was proposed. The effects of the reaction parameters, including reagent concentrations, reaction flow rate, coil length, reaction temperature, and pH were optimized. Under optimal conditions, this method afforded a sampling rate of 8 h-1, a limit of detection of 0.045 μmol L-1, and RSD of 3.68% (n = 14) with 1.50 μmol L-1 ammonium, and the calibration range was 0.045-6.00 μmol L-1. Examination of the organic nitrogen interference confirmed that the method attracts minimal interference from organic nitrogen, and the stability of the NDA reagent facilitates its field application. Other exhibited advantages include low reagent consumption and high automation; the method has been utilized in the successful determination of ammonium in freshwater and rainwater. The development of NDA applications for ammonium determination also provides more options for fluorometric determination of ammonium.
Collapse
Affiliation(s)
- Xuejia Chen
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Min Zhang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Xuejun Li
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China
| | - Jin Xu
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.
| | - Ying Liang
- School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.
| |
Collapse
|
16
|
Osman AM, Hendi A, Osman NMA. Multiwalled Carbon Nanotubes-Modified Metallic Electrode Prepared Using Chemical Vapor Deposition as Sequential Injection Analysis Detector for Determination of Ascorbic Acid. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1264. [PMID: 37049357 PMCID: PMC10096536 DOI: 10.3390/nano13071264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/31/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
A carbon nanotubes modified silver electrode (CNTs-Ag) was prepared via catalytic chemical vapor deposition and characterized. The morphology, crystallinity, elemental composition, and other quality parameters of the prepared electrode were investigated using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and Raman techniques. The characterization results revealed the modification of the silver metal surface with CNTs of good characteristics. A sequential injection analysis (SIA) system was developed for studying the reaction of ascorbic acid with KIO3 using the prepared CNTs-Ag electrode. Electrodes were polarized with both direct current (DC) and periodic square wave (SW). Various experimental conditions affecting the differential electrolytic potentiometric (DEP) peak such as current density, SW bias value, and flow rate were appraised. Under the optimum conditions, good linear responses for ascorbic acid were obtained in the range of 60.0-850.0 µM for both types of polarization with detection limits of 14.0-19.0 µM. The results obtained showed that the periodic polarization method was more sensitive than DC polarization and the electrode response was faster. Ascorbic acid in pharmaceutical tablets was determined with satisfactory results using this method. The prepared CNTs-based electrode exhibited good performance for a long period of use. The method is simple, rapid, and inexpensive for routine analysis.
Collapse
Affiliation(s)
- Abdalghaffar M. Osman
- Chemistry Department, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
- Interdisciplinary Research Center (IRC) for Advanced Materials, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
| | - Abdulmajeed Hendi
- Physics Department, Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
- Interdisciplinary Research Center (IRC) for Hydrogen and Energy Storage, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
| | - Nadir M. A. Osman
- Chemistry Department, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
| |
Collapse
|
17
|
Online sample preparation of milk samples for spectrophotometric determination of formaldehyde in milk. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2023.105271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/09/2023]
|
18
|
Zhao Z, Xiao J, Zhang X, Jiang J, Zhang M, Li Y, Li T, Wang J. A Thread-based Micro Device for Continuous Electrochemical Detection of Saliva Urea. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
|
19
|
A Multi-Pumping Gradient Calibration Module for Potentiometric Determination of Nitrate in Surface Water. MOLECULES (BASEL, SWITZERLAND) 2023; 28:molecules28020493. [PMID: 36677550 PMCID: PMC9867143 DOI: 10.3390/molecules28020493] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/19/2022] [Accepted: 12/30/2022] [Indexed: 01/06/2023]
Abstract
The novel, automated, multi-pumping flow system (MPFS) for online calibration and determination of nitrate in surface water is presented for the first time. The system was equipped with micropumps of three different nominal volumes (10, 20, and 50 µL). As a result, it was possible to prepare from one standard, directly in a flow system, up to seven standard solutions. Determination of nitrate was conducted in stop-flow conditions and is based on a commercially available ion selective electrode (ISE) application. It was found that the linearity and slope of the calibration graphs depend mainly on the characteristics of the ISE. The obtained results were very repeatable, owing to the high precision of the micro-pumps used. The R.S.D. for the stroke volume of each micro-pump was below 1%. The accuracy of the method was checked through determination of nitrate in surface water samples. The obtained results were compared with those of the reference method (photometric Hach cuvette tests). It was found that, at a 96% confidence level, the difference between the results obtained by the proposed method and the reference method was statistically insignificant. The accuracy of the method was confirmed through the determination of nitrate in Certified Reference Material. The relative deviation (R.D.) of the measured and the certified concentrations was 5%.
Collapse
|
20
|
Trends in advanced materials for the fabrication of insulin electrochemical immunosensors. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02416-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
21
|
Kajner G, Kéri A, Bélteki Á, Valkai S, Dér A, Geretovszky Z, Galbács G. Multifunctional microfluidic chips for the single particle inductively coupled plasma mass spectrometry analysis of inorganic nanoparticles. LAB ON A CHIP 2022; 22:2766-2776. [PMID: 35786729 DOI: 10.1039/d2lc00377e] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
This study aimed at exploiting the so far unexploited potential of carrying out on-line sample pretreatment steps on microfluidic chips for single particle inductively coupled plasma mass spectrometry (spICP-MS) measurements, and demonstrating their ability to practically facilitate most of the simpler tasks involved in the spICP-MS analysis of nanoparticles. For this purpose, polydimethylsiloxane microfluidic chips, capable of high-range dilution and sample injection were made by casting, using high-precision, 3D-printed molds. Optimization of their geometry and functions was done by running several hydrodynamic simulations and by gravimetric, fluorescence enhanced microscope imaging and solution-based ICP-MS experiments. On the optimized microfluidic chips, several experiments were done, demonstrating the benefits of the approach and these devices, such as the determination of nanoparticle concentration using only a few tens of microliters of sample, elimination of solute interferences by dilution, solution-based size calibration and characterisation of binary nanoparticles. Due to the unique design of the chips, they can be linked together to extend the dilution range of the system by more than a magnitude per chip. This feature was also demonstrated in applications requiring multiple-magnitude dilution rates, when two chips were sequentially coupled.
Collapse
Affiliation(s)
- Gyula Kajner
- Dept. of Inorg, and Anal. Chem, Univ. of Szeged, Dóm sq. 7, H-6720 Szeged, Hungary.
| | - Albert Kéri
- Dept. of Inorg, and Anal. Chem, Univ. of Szeged, Dóm sq. 7, H-6720 Szeged, Hungary.
| | - Ádám Bélteki
- Dept. of Inorg, and Anal. Chem, Univ. of Szeged, Dóm sq. 7, H-6720 Szeged, Hungary.
| | - Sándor Valkai
- Inst. of Biophys, Biol. Res. Cent, Temesvári blvd. 62, H-6726 Szeged, Hungary
| | - András Dér
- Inst. of Biophys, Biol. Res. Cent, Temesvári blvd. 62, H-6726 Szeged, Hungary
| | - Zsolt Geretovszky
- Dept. of Opt, and Quant. Electr. Univ. of Szeged, Dóm sq. 9, H-6720 Szeged, Hungary
| | - Gábor Galbács
- Dept. of Inorg, and Anal. Chem, Univ. of Szeged, Dóm sq. 7, H-6720 Szeged, Hungary.
| |
Collapse
|
22
|
Das S, Das PP, Walton JW, Ghoshal K, Patra L, Bhattacharyya M. An excited state intramolecular proton transfer induced phosphate ion targeted ratiometric fluorescent switch to monitor phosphate ions in human peripheral blood mononuclear cells. Dalton Trans 2022; 51:10779-10786. [PMID: 35611756 DOI: 10.1039/d2dt00581f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Detection of biological phosphate is very important for environmental and health care applications. In this study, a new ratiometric fluorescent probe (E)-N'-(3-(benzo[d]thiazol-2-yl)-2-hydroxybenzylidene) picolinohydrazide (BTP) is developed and exhibits a prominent excited-state intramolecular proton-transfer (ESIPT) mechanism. The probe BTP undergoes a unique phosphate induced hydrolytic reaction in mixed aqueous solution which produces a colorimetric change associated with a huge red-shift of ∼130 nm in the UV-visible absorption spectrum. Initially, BTP exhibits a strong fluorescence emission as the ESIPT process is 'on' and the tautomeric hydrogen remains flexible and is free to give two tautomeric forms. Eventually, after the addition of PO43-, the two tautomeric forms break and thereby shift the equilibrium towards the 'enol' form. The phosphate ion binds with BTP which is associated with a ratiometric change and accounts for an enhancement in the fluorescence intensity with a large blue shift and the limit of detection value of 8.33 × 10-8 M in a mixed aqueous medium. The binding constant (1.92 × 105 M-1) proportionally reflects the stability of the complexation between the binding sites of BTP with the guest PO43- anion. The probable mechanism is supported by the NMR spectroscopy studies. The sensing phenomenon is found to be reversible towards Zn2+ and thus the sensor beautifully mimics the INHIBIT logic gate. Observations have been made in fluorescence imaging studies with human peripheral blood mononuclear cells (PBMCs) which indicates that BTP can be employed to successfully monitor the phosphate ion in human PBMCs.
Collapse
Affiliation(s)
- Sangita Das
- Durham University, Department of Chemistry, Durham, DH1 3LE, UK.
| | - Partha Pratim Das
- Center for Novel States of Complex Materials Research, Seoul National University, Seoul, 08826, Republic of Korea
| | - James W Walton
- Durham University, Department of Chemistry, Durham, DH1 3LE, UK.
| | - Kakali Ghoshal
- Department of Biochemistry, University of Calcutta, Kolkata 700019, India
| | | | | |
Collapse
|
23
|
Resano M, Aramendía M, García-Ruiz E, Bazo A, Bolea-Fernandez E, Vanhaecke F. Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events. Chem Sci 2022; 13:4436-4473. [PMID: 35656130 PMCID: PMC9020182 DOI: 10.1039/d1sc05452j] [Citation(s) in RCA: 33] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Accepted: 03/14/2022] [Indexed: 11/21/2022] Open
Abstract
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
Collapse
Affiliation(s)
- M Resano
- Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza Pedro Cerbuna 12 50009 Zaragoza Spain
| | - M Aramendía
- Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza Pedro Cerbuna 12 50009 Zaragoza Spain
- Centro Universitario de la Defensa de Zaragoza Carretera de Huesca s/n 50090 Zaragoza Spain
| | - E García-Ruiz
- Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza Pedro Cerbuna 12 50009 Zaragoza Spain
| | - A Bazo
- Department of Analytical Chemistry, Aragón Institute of Engineering Research (I3A), University of Zaragoza Pedro Cerbuna 12 50009 Zaragoza Spain
| | - E Bolea-Fernandez
- Ghent University, Department of Chemistry, Atomic & Mass Spectrometry - A&MS Research Unit Campus Sterre, Krijgslaan 281-S12 9000 Ghent Belgium
| | - F Vanhaecke
- Ghent University, Department of Chemistry, Atomic & Mass Spectrometry - A&MS Research Unit Campus Sterre, Krijgslaan 281-S12 9000 Ghent Belgium
| |
Collapse
|
24
|
Trojanowicz M, Pyszynska M. Flow-Injection Methods in Water Analysis-Recent Developments. Molecules 2022; 27:1410. [PMID: 35209198 PMCID: PMC8879103 DOI: 10.3390/molecules27041410] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/10/2022] Open
Abstract
Widespread demand for the analysis and control of water quality and supply for human activity and ecosystem sustainability has necessitated the continuous improvement of water analysis methods in terms of their reliability, efficiency, and costs. To satisfy these requirements, flow-injection analysis using different detection methods has successfully been developed in recent decades. This review, based on about 100 original research papers, presents the achievements in this field over the past ten years. Various methodologies for establishing flow-injection measurements are reviewed, together with microfluidics and portable systems. The developed applications mostly concern not only the determination of inorganic analytes but also the speciation analysis of different elements, and the determination of several total indices of water quality. Examples of the determination of organic residues (e.g., pesticides, phenolic compounds, and surfactants) in natural surface waters, seawater, groundwater, and drinking water have also been identified. Usually, changes in the format of manual procedures for flow-injection determination results in the improvement of various operational parameters, such as the limits of detection, the sampling rate, or selectivity in different matrices.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
- Department of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Marta Pyszynska
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
| |
Collapse
|
25
|
Reducing the channel diameter of polydimethylsiloxane fluidic chips made by a 3D-printed sacrificial template and their application for flow-injection analysis. ANAL SCI 2022; 38:583-589. [PMID: 35286631 PMCID: PMC8971176 DOI: 10.1007/s44211-022-00070-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 12/20/2021] [Indexed: 11/27/2022]
Abstract
AbstractFluidic chips have attracted considerable interest in recent years for their potential applications in analytical devices. Previously, we developed a method to fabricate polydimethylsiloxane (PDMS) fluidic chips via templates made using a low-priced commercial Fused Deposition Modeling (FDM) type 3D printer and polymer coatings. However, in general, methods using a template cannot form a flow channel thinner than the template thickness and the width. In this study, the inner wall of a PDMS fluidic chip was coated with PDMS to create a chip with a channel inner diameter smaller than a template. Then, by measuring the flow signal of methyl orange with a single line, the basic properties of the non-coated and coated chip were investigated. As a result, almost the same flow profile was obtained in non-coated and coated chips at the same linear velocity and the same sample injection length. By coating and narrowing the channel width, it is possible to save the amount of sample and carrier solution. Measuring hydrazine in water using a coated chip was also tried. The calibration curve indicated good linearity in the range of 1–6 ppm. However, a concentration point of 7 ppm deviated. The reason for this deviation was presumably due to inadequate mixing of the sample and reagent. By decreasing the flow rate, the calibration curve indicated good linearity in the range of 1–7 ppm.
Graphical abstract
Collapse
|
26
|
Paluch J, Kozak J, Mermer K, Molęda I, Wieczorek M, Kalinowski S, Kościelniak P. Novel Integrated Flow-Based Steam Distillation and Titration System for Determination of Volatile Acidity in Wines. Molecules 2021; 26:molecules26247673. [PMID: 34946754 PMCID: PMC8708693 DOI: 10.3390/molecules26247673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/14/2021] [Accepted: 12/15/2021] [Indexed: 12/03/2022] Open
Abstract
Novel integrated flow-based steam distillation and titration system with spectrophotometric detection was developed for determination of volatile acidity in wines. Using the system, the distillation procedure was carried out in an automatic manner, starting with introducing into a heated steam distillation module a sample and subjecting it to steam distillation. Under selected conditions, all the analyte was transferred to the distillate; therefore, the system did not require calibration. The collected distillate and titrant were introduced into the next monosegments in varying proportions, in accordance with the developed titration procedure, and directed to the detection system to record the titration curve. The titration was stopped after reaching the end point of titration. Procedures for distillation and titration were developed and verified separately by distillation of acetic acid, acetic acid in the presence of tartaric acid as well as acetic acid, tartaric acid, and titratable acidity, with precision (relative standard deviation) and accuracy (relative error) for both procedures lower than 6.9 and 5.6%, respectively. The developed steam distillation and titration systems were used to determine volatile acidity in samples of white and rosé wines separately and as the integrated steam distillation and titration system, both with precision lower than 9.4% and accuracy better than 6.7%.
Collapse
Affiliation(s)
- Justyna Paluch
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
- Correspondence: (J.P.); (J.K.)
| | - Joanna Kozak
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
- Correspondence: (J.P.); (J.K.)
| | - Karolina Mermer
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
| | - Iwona Molęda
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
| | - Marcin Wieczorek
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
| | - Sławomir Kalinowski
- Department of Chemistry, University of Warmia and Mazury, Plac Łódzki 4, 10-957 Olsztyn, Poland;
| | - Paweł Kościelniak
- Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland; (K.M.); (I.M.); (M.W.); (P.K.)
| |
Collapse
|
27
|
Zardi P, Carofiglio T, Maggini M. Mild Microfluidic Approaches to Oxide Nanoparticles Synthesis. Chemistry 2021; 28:e202103132. [PMID: 34841599 PMCID: PMC9300203 DOI: 10.1002/chem.202103132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Indexed: 11/09/2022]
Abstract
Oxide nanoparticles (oxide NPs) are advanced materials with a wide variety of applications in different fields. The use of continuous flow methods is particularly appealing for their synthesis due to the high control achieved over the reaction conditions and the easy process scalability. The present review focuses on the preparation of oxide NPs using microfluidic setups at low temperature (≤80 °C), since the employment of mild reaction conditions is crucial for developing sustainable and cost-effective processes. A particular emphasis will be put on the improvement over the final product features (e. g., size, shape, and size distribution) given by flow methods with respect to conventional batch procedures. The main issues that arise by treating NPs suspensions in microfluidic systems are product deposition or channel clogging; mitigation strategies to overcome these drawbacks will also be presented and discussed.
Collapse
Affiliation(s)
- Paolo Zardi
- Department of Chemical Sciences, University of Padova, Via Francesco Marzolo 1, 35131, Padova, Italy
| | - Tommaso Carofiglio
- Department of Chemical Sciences, University of Padova, Via Francesco Marzolo 1, 35131, Padova, Italy
| | - Michele Maggini
- Department of Chemical Sciences, University of Padova, Via Francesco Marzolo 1, 35131, Padova, Italy
| |
Collapse
|
28
|
Fabrication of an All-Solid-State Ammonium Paper Electrode Using a Graphite-Polyvinyl Butyral Transducer Layer. CHEMOSENSORS 2021. [DOI: 10.3390/chemosensors9120333] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
A planar solid-state ammonium-selective electrode, employing a composite mediator layer of graphite particles embedded in a polyvinyl butyral matrix on top of an inkjet-printed silver electrode, is presented in this paper. The effect of graphite powder mass fraction on the magnitude of the potentiometric response of the sensor was systematically verified using a batch-mode and a flow injection measurement setup. Under steady-state conditions, the paper electrode provided a Nernstian response of 57.30 mV/pNH4 over the concentration range of 10−5 M to 10−1 M with a detection limit of 4.8 × 10−6 M, while the analytical performance of the array in flow mode showed a narrower linear range (10−4 M to 10−1 M; 60.91 mV/pNH4 slope) with a LOD value of 5.6 × 10−5 M. The experimental results indicate that the prepared electrode exhibited high stability and fast response to different molar concentrations of ammonium chloride solutions. The pH-response of the paper NH4-ISE was also investigated, and the sensor remained stable in the pH range of 2.5–8.5. The potentiometric sensor presented here is simple, lightweight and inexpensive, with a potential application for in-situ analysis of environmental water samples.
Collapse
|
29
|
Status and advances in technologies for phosphorus species detection and characterization in natural environment- A comprehensive review. Talanta 2021; 233:122458. [PMID: 34215099 DOI: 10.1016/j.talanta.2021.122458] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/19/2021] [Accepted: 04/22/2021] [Indexed: 12/30/2022]
Abstract
Poor recovery of phosphorus (P) across natural environment (water, soil, sediment, and biological sources) is causing rapid depletion of phosphate rocks and continuous accumulation of P in natural waters, resulting in deteriorated water quality and aquatic lives. Accurate detection and characterization of various P species using suitable analytical methods provide a comprehensive understanding of the biogeochemical cycle of P and thus help its proper management in the environment. This paper aims to provide a comprehensive review of the analytical methods used for P speciation in natural environment by dividing them into five broad categories (i.e., chemical, biological, molecular, staining microscopy, and sensors) and highlighting the suitability (i.e., targeted species, sample matrix), detection limit, advantages-limitations, and reference studies of all methods under each category. This can be useful in designing studies involving P detection and characterization across environmental matrices by providing insights about a wide range of analytical methods based on the end user application needs of individual studies.
Collapse
|
30
|
Głowacka J, Strzelak K, Koncki R. Multicommutated Flow Analysis System for Determination of Horseradish Peroxidase and Its Inhibitors. Molecules 2021; 26:molecules26185630. [PMID: 34577101 PMCID: PMC8465280 DOI: 10.3390/molecules26185630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 09/08/2021] [Accepted: 09/13/2021] [Indexed: 11/16/2022] Open
Abstract
A fully mechanized multicommutated flow analysis (MCFA) system dedicated to determining horseradish peroxidase (HRP) activity was developed. Detection was conducted using a flow-through optoelectronic detector-constructed of paired LEDs operating according to the paired emitter-detector diode (PEDD) principle. The PEDD-MCFA system is dedicated to monitoring the enzyme-catalyzed oxidation of p-phenylenediamine (pPD) by a hydrogen peroxide. Under optimized conditions, the presented bioanalytical system was characterized by a linear response range (33.47-200 U/L) with a detection limit at 10.54 U/L HRP activity and 1.66 mV·L/U sensitivity, relatively high throughput (12 signals recordings per hour), and acceptable precision (RSD below 6%). Additionally, the utility of the developed PEDD-MCFA system for the determination of HRP inhibitors allowing the detection of selected thiols at micromolar levels, is demonstrated. The practical utility of the flow system was illustrated by the analysis of some dietary supplements containing L-cysteine, N-acetylcysteine, and L-glutathione.
Collapse
|
31
|
Gemuh CV, Horstkotte B, Solich P. Lab-In-Syringe with Bead Injection Coupled Online to High-Performance Liquid Chromatography as Versatile Tool for Determination of Nonsteroidal Anti-Inflammatory Drugs in Surface Waters. Molecules 2021; 26:molecules26175358. [PMID: 34500791 PMCID: PMC8433787 DOI: 10.3390/molecules26175358] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 08/30/2021] [Indexed: 11/16/2022] Open
Abstract
We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes. Packing of ca. 4.4 mg microSPE columns from Oasis HLB® sorbent slurry was performed for each sample analysis using a simple microcolumn adapted to the Lab-On-Valve manifold to achieve low backpressure during loading. Eluted analytes were injected into online coupled HPLC with subsequent separation on a Symmetry C18 column in isocratic mode. The optimized method was highly reproducible, with RSD values of 3.2% to 7.6% on 20 µg L-1 level. Linearity was confirmed up to 200 µg L-1 and LOD values were between 0.06 and 1.98 µg L-1. Recovery factors between 91 and 109% were obtained in the analysis of spiked surface water samples.
Collapse
|
32
|
Bzura J, Korsak D, Koncki R. Bioanalytical insight into the life of microbial populations: A chemical monitoring of ureolytic bacteria growth. Enzyme Microb Technol 2021; 153:109899. [PMID: 34670184 DOI: 10.1016/j.enzmictec.2021.109899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/23/2021] [Accepted: 08/27/2021] [Indexed: 11/03/2022]
Abstract
In this publication an alternative approach to investigations of bacterial growth is proposed. Contrary to the conventional physical methods it is based on enzyme activity detection. The procedure for real-time and on-line monitoring of microbial ureolytic activity (applied as a model experimental biosystem) in the flow analysis format is presented. The developed fully-mechanized bioanalytical flow system is composed of solenoid micropumps and microvalves actuated by Arduino microcontroller. The photometric detection based on Nessler reaction is performed using dedicated flow-through optoelectronic detector made of paired light emitting diodes. The developed bioanalytical system allows discrete assaying of microbial urease in the wide range of activity up to 5.4 U mL-1 with detection limit below 0.44 U mL-1, a high sensitivity in the linear range of response (up to 200 mV U-1 mL and relatively high throughput (9 detection per hour). The proposed differential procedure of measurements (i.e. a difference between peaks register for sample with and without external addition of urea is treated as an analytical signal) allows elimination of interfering effects from substrate and products of biocatalysed reaction as well as other components of medium used for microbial growth. The developed bioanalytical system was successfully applied for the control of growth of urease-positive bacteria strains (Proteus vulgaris, Klebsiella pneumoniae and Paracoccus yeei) including examination of effects from various microbial cultivation conditions like temperature, composition of culture medium and amount of substrate required for induction of bacterial enzymatic activity. The developed bioanalytical flow system can be applied for metabolic activity-based estimation of parameters of lag and log phases of microbial growth as well as for detection of decline phase.
Collapse
Affiliation(s)
- Justyna Bzura
- Faculty of Chemistry, University of Warsaw, L. Pasteura 1, 02-093, Warsaw, Poland
| | - Dorota Korsak
- Faculty of Biology, University of Warsaw, I. Miecznikowa 1, 02-096, Warsaw, Poland
| | - Robert Koncki
- Faculty of Chemistry, University of Warsaw, L. Pasteura 1, 02-093, Warsaw, Poland.
| |
Collapse
|
33
|
Abstract
The multiple therapeutic potentials of tetracycline and its worldwide usage have encouraged researchers to develop various methods for its assay in various matrices and for different purposes. In this regard, different analytical techniques have been exploited. Among those techniques is flow injection (FI), which is an extended family of three generations and five versions. The current manuscript reviews the utilization of FI techniques for developing assay methods for tetracycline. The review covers more than forty methods, since the inception of FI techniques and up to date. The review highlights the advantages of the application of FI techniques for quantification of tetracycline in terms of reagent consumption, sample frequency, accuracy, and practitioner safety, besides instrumentation simplicity and cost-effectiveness. The review also addresses applications to several matrices ranging from simple matrices such as standard solutions and pharmaceutical formulations to complex matrices such as biological fluids and food. Prior to the review, a brief background on the principles and developments of FI techniques is illustrated.
Collapse
Affiliation(s)
- Mohammed D Y Oteef
- Department of Chemistry, College of Science, Jazan University, Jazan, Saudi Arabia
| | - Abubakr M Idris
- Department of Chemistry, College of Science, King Khalid University, Abha, Saudi Arabia.,Research Center for Advanced Materials Science (RCAMS), King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
34
|
Electroanalysis of Iron in Groundwater by Defective Carbon Black Modified Electrode. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2021. [DOI: 10.1016/s1872-2040(21)60106-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
35
|
Dębosz M, Kozma J, Porada R, Wieczorek M, Paluch J, Gyurcsányi RE, Migdalski J, Kościelniak P. 3D-printed manifold integrating solid contact ion-selective electrodes for multiplexed ion concentration measurements in urine. Talanta 2021; 232:122491. [PMID: 34074448 DOI: 10.1016/j.talanta.2021.122491] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/26/2021] [Accepted: 04/29/2021] [Indexed: 01/26/2023]
Abstract
Urinalysis is a simple and non-invasive approach for the diagnosis and monitoring of various health disorders. While urinalysis is predominantly confined to clinical laboratories the non-invasive sample collection makes it applicable in wide range of settings outside of central laboratory confinements. In this respect, 3D printed devices integrating sensors for measuring multiple parameters may be one of the most viable approaches to ensure cost-effectiveness for widespread use. Here we evaluated such a system for the multiplexed determination of sodium, potassium and calcium ions in urine samples with ion-selective electrodes based on state of the art octadecylamine-functionalized multi-walled carbon nanotube (OD-MWCNT) solid contacts. The electrodes were tested in the clinically relevant concentration range, i.e. ca. 10-4 - 10-1 mol L-1 and were proven to have Nernstian responses under flow injection conditions. The applicability of the 3D printed flow manifold was investigated through the analysis of synthetic samples and two certified reference materials. The obtained results confirm the suitability of the proposed system for multiplexed ion analysis in urine.
Collapse
Affiliation(s)
- Marek Dębosz
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland.
| | - József Kozma
- Budapest University of Technology and Economics, Department of Inorganic and Analytical Chemistry, BME "Lendület" Chemical Nanosensors Research Group, Szt. Gellért Tér 4, H-1111, Budapest, Hungary
| | - Radosław Porada
- AGH-University of Science and Technology in Cracow, Faculty of Materials Science and Ceramics, Department of Analytical Chemistry and Biochemistry, Al. Mickiewicza 30, Kraków, Poland
| | - Marcin Wieczorek
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| | - Justyna Paluch
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| | - Róbert E Gyurcsányi
- Budapest University of Technology and Economics, Department of Inorganic and Analytical Chemistry, BME "Lendület" Chemical Nanosensors Research Group, Szt. Gellért Tér 4, H-1111, Budapest, Hungary
| | - Jan Migdalski
- AGH-University of Science and Technology in Cracow, Faculty of Materials Science and Ceramics, Department of Analytical Chemistry and Biochemistry, Al. Mickiewicza 30, Kraków, Poland
| | - Paweł Kościelniak
- Jagiellonian University in Krakow, Faculty of Chemistry, Department of Analytical Chemistry, Ul. Gronostajowa 2, Krakow, Poland
| |
Collapse
|
36
|
Maringolo V, Aleixo FC, Carvalho AZ, Rocha DL. Exploitation of flow-based procedures for reagentless hydrochlorothiazide determination and accelerated degradation studies of pharmaceutical preparations. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:497-503. [PMID: 33437973 DOI: 10.1039/d0ay02070b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Drug quality assessment and stress testing are important to ensure both treatment efficacy and patient safety. High performance liquid chromatography may be considered a standard technique for pharmaceutical analysis, showing good precision and accuracy, but it also involves relatively high cost and low analytical frequency. Flow injection analysis presents high sample throughput, lower cost and might be used for selective drug analysis with an appropriate assay and/or detector. In this paper, for the first time, photoreactions promoted by UV radiation were employed for reagentless spectrophotometric determination of hydrochlorothiazide. Optimized parameters led to a linear range of 50 to 500 mg L-1, estimated limit of detection of 3.0 mg L-1 and 24 determinations per hour. The use of diluted NaOH solution as a carrier allowed solubilization of hydrochlorothiazide and analysis without organic solvents. The presence of the most common excipients was evaluated and no significant interferences were observed. The results from the analysis of samples by the proposed and by the reference procedures demonstrated accuracy and matching results. The proposed in-line photolysis of the pharmaceutical, performed in 5 min, is a promising alternative to the conventional hydrolytic forced degradation, which requires elevated temperature and prolonged time period. To evaluate the degree of photoconversion, a capillary zone electrophoresis method was developed, which performed well for separations manifesting good analytical frequency and reduced amount of waste. The combination of in-line photodegradation followed by separation by capillary electrophoresis is a promising approach for the stress test of hydrochlorothiazide in pharmaceutical formulations.
Collapse
Affiliation(s)
- Vivian Maringolo
- Center on Natural and Human Sciences, Federal University of ABC, 09210-580 - Santo André- SP, Brazil.
| | | | | | | |
Collapse
|
37
|
Rani R, Singh G, Batra K, Minakshi P. Bioengineered Polymer/Composites as Advanced Biological Detection of Sorbitol: An Application in Healthcare Sector. Curr Top Med Chem 2021; 20:963-981. [PMID: 32141419 DOI: 10.2174/1568026620666200306131416] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 01/20/2020] [Accepted: 01/31/2020] [Indexed: 12/23/2022]
Abstract
Bioengineered polymers and nanomaterials have emerged as promising and advanced materials for the fabrication and development of novel biosensors. Nanotechnology-enabled biosensor methods have high sensitivity, selectivity and more rapid detection of an analyte. Biosensor based methods are more rapid and simple with higher sensitivity and selectivity and can be developed for point-of-care diagnostic testing. Development of a simple, sensitive and rapid method for sorbitol detection is of considerable significance to efficient monitoring of diabetes-associated disorders like cataract, neuropathy, and nephropathy at initial stages. This issue encourages us to write a review that highlights recent advancements in the field of sorbitol detection as no such reports have been published till the date. The first section of this review will be dedicated to the conventional approaches or methods that had been playing a role in detection. The second part focused on the emerging field i.e. biosensors with optical, electrochemical, piezoelectric, etc. approaches for sorbitol detection and the importance of its detection in healthcare application. It is expected that this review will be very helpful for readers to know the different conventional and recent detection techniques for sorbitol at a glance.
Collapse
Affiliation(s)
- Ruma Rani
- ICAR-National Research Centre on Equines, Hisar-125001, India
| | - Geeta Singh
- Deenbandhu Chhotu Ram University of Science and Technology, Murthal-131027, Sonipat, India
| | - Kanisht Batra
- Department of Animal Biotechnology, LLR University of Veterinary and Animal Sciences, Hisar-125001, Haryana, India
| | - Prasad Minakshi
- Department of Animal Biotechnology, LLR University of Veterinary and Animal Sciences, Hisar-125001, Haryana, India
| |
Collapse
|
38
|
Calvo-López A, Ymbern O, Puyol M, Alonso-Chamarro J. Soluble reactive phosphorous determination in wastewater treatment plants by automatic microanalyzers. Talanta 2021; 221:121508. [PMID: 33076102 DOI: 10.1016/j.talanta.2020.121508] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/31/2020] [Accepted: 08/03/2020] [Indexed: 02/07/2023]
Abstract
The analysis of soluble reactive phosphate (SRP) in water is key to control water quality. In order to continuous monitor orthophosphate content in water during treatment processes and in the effluents of wastewater treatment plants, conventional procedures, usually performed in a laboratory, must be adapted. This means pursuing efforts on miniaturizing systems to operate in situ and automating analytical methods to work on-line. The design, construction and evaluation of an automatic and low cost cyclic olefin copolymer (COC)-based spectrophotometric microanalyzer, capable of operating in unattended conditions, is presented to monitor soluble reactive phosphorous, as orthophosphate ion, in wastewater samples coming from sewage treatment plants. The microsystem, constructed by CNC micromilling and using a multilayer approach, integrates microfluidics to carry out the phosphomolybdenum blue (PMB) reaction and an optical flow-cell for the spectrophotometric orthophosphate determination in a single polymeric substrate smaller than a credit card. It is connected to a compact optical detection system composed by a LED emitting at 660 nm and a PIN-photodiode, both integrated in a PCB. Flow management is automatically performed by programmed microvalves and micropumps, which control autocalibration processes and allow unattended operation. Analytical features after the optimization of the microfluidic platform and the chemical and the hydrodynamic variables, were a linear range from 0.09 to 32 mg L-1 P and a detection limit of 0.03 mg L-1 P with a sampling rate of 24 samples h-1, demonstrating the microanalyzer suitability for SRP monitoring in water. Moreover, real samples were analyzed obtaining promising results.
Collapse
Affiliation(s)
- Antonio Calvo-López
- Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193 Bellaterra, Barcelona, Spain
| | - Oriol Ymbern
- Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193 Bellaterra, Barcelona, Spain
| | - Mar Puyol
- Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193 Bellaterra, Barcelona, Spain
| | - Julián Alonso-Chamarro
- Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193 Bellaterra, Barcelona, Spain.
| |
Collapse
|
39
|
Gordeev EG, Ananikov VP. Widely accessible 3D printing technologies in chemistry, biochemistry and pharmaceutics: applications, materials and prospects. RUSSIAN CHEMICAL REVIEWS 2020. [DOI: 10.1070/rcr4980] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
40
|
Lazaridou E, Kabir A, Furton KG, Anthemidis A. A Novel Glass Fiber Coated with Sol-Gel Poly-Diphenylsiloxane Sorbent for the On-Line Determination of Toxic Metals Using Flow Injection Column Preconcentration Platform Coupled with Flame Atomic Absorption Spectrometry. Molecules 2020; 26:molecules26010009. [PMID: 33375078 PMCID: PMC7792807 DOI: 10.3390/molecules26010009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/18/2020] [Accepted: 12/18/2020] [Indexed: 11/16/2022] Open
Abstract
A novel simple and sensitive, time-based flow injection solid phase extraction system was developed for the automated determination of metals at low concentration. The potential of the proposed scheme, coupled with flame atomic absorption spectrometry (FAAS), was demonstrated for trace lead and chromium(VI) determination in environmental water samples. The method, which was based on a new sorptive extraction system, consisted of a microcolumn packed with glass fiber coated with sol-gel poly (diphenylsiloxane) (sol-gel PDPS), which is presented here for the first time. The analytical procedure involves the on-line chelate complex formation of target species with ammonium pyrrolidine dithiocarbamate (APDC), retention onto the hydrophobic sol-gel sorbent coated surface of glass fibers, and finally elution with methyl isobutyl ketone prior to atomization. All main chemical and hydrodynamic factors, which affect the complex formation, retention, and elution of the metal, were optimized thoroughly. Furthermore, the tolerance to potential interfering ions appearing in environmental samples was also explored. Enhancement factors of 215 and 70, detection limits (3 s) of 1.1 μg·L-1 and 1.2 μg·L-1, and relative standard deviations (RSD) of 3.0% (at 20.0 μg·L-1) and 3.2% (at 20.0 μg·L-1) were obtained for lead and chromium(VI), respec tively, for 120 s preconcentration time. The trueness of the developed method was estimated by analyzing certified reference materials and spiked environmental water samples.
Collapse
Affiliation(s)
- Eleni Lazaridou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, 54124 Thessaloniki, Greece;
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33131, USA; (A.K.); (K.G.F.)
| | - Kenneth G. Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33131, USA; (A.K.); (K.G.F.)
| | - Aristidis Anthemidis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, 54124 Thessaloniki, Greece;
- Correspondence: ; Tel.: +30-2310-99-7826
| |
Collapse
|
41
|
Khumngern S, Jirakunakorn R, Thavarungkul P, Kanatharana P, Numnuam A. A highly sensitive flow injection amperometric glucose biosensor using a gold nanoparticles/polytyramine/Prussian blue modified screen-printed carbon electrode. Bioelectrochemistry 2020; 138:107718. [PMID: 33333458 DOI: 10.1016/j.bioelechem.2020.107718] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 11/18/2020] [Accepted: 11/21/2020] [Indexed: 12/22/2022]
Abstract
A novel oxidase enzyme sensor was fabricated based on the chemisorption of highly active glucose oxidase (GOx) on gold nanoparticles that were adsorbed on a polytyramine layer (AuNPs/Pty). The GOx/AuNPs/Pty assembly was coated on a Prussian blue (PB)-modified screen-printed carbon electrode (SPCE) to produce the GOx/AuNPs/Pty/PB/SPCE biosensor. The amperometric glucose biosensor response was measured at -0.10 V using a Ag pseudo-reference electrode through the reduction current of the PB mediator in a flow injection analysis system. Under optimised experimental conditions, the developed biosensor displayed linearity over the 1.0 μM-1.0 mM glucose concentration range and a limit of detection of 1.0 μM (S/N ≥ 3). A low value for the Michaelis constant of 0.21 mM indicated that the immobilised GOx had high affinity for glucose. The developed biosensor exhibited excellent operational stability over 374 injections, long-term stability over 3 weeks, good reproducibility (relative standard deviations = 1.9%-4.3%) and high selectivity. The results obtained analysing glucose in blood plasma samples were satisfactory when compared with the corresponding results recorded implementing the standard hexokinase-spectrophotometric method (P > 0.05).
Collapse
Affiliation(s)
- Suntisak Khumngern
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Ratchaneekorn Jirakunakorn
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Panote Thavarungkul
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Proespichaya Kanatharana
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand
| | - Apon Numnuam
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand.
| |
Collapse
|
42
|
Coloma A, Del Pozo M, Martínez-Moro R, Blanco E, Atienzar P, Sánchez L, Petit-Domínguez MD, Casero E, Quintana C. MoS 2 quantum dots for on-line fluorescence determination of the food additive allura red. Food Chem 2020; 345:128628. [PMID: 33342608 DOI: 10.1016/j.foodchem.2020.128628] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/15/2020] [Accepted: 11/10/2020] [Indexed: 01/16/2023]
Abstract
This work presents an on-line fluorescence method for the allura red (AR) determination. The method is based on the fluorescence quenching of dots of MoS2 because of their interaction with the non-fluorescence dye. MoS2-dots were synthetized and characterized by spectroscopic techniques and High Resolution Transmission Electronic Microscopy (HR-TEM). The simultaneous injection of the nanomaterial and the dye in a flow injection analysis system allows the determination of allura red at 1.7 × 10-6 M concentration level with a very good accuracy and precision (Er minor than 10% and RSD lower than 8%) and a sampling frequency of 180 samples per hour. Moreover, the interaction fluorophore-quencher results a dynamic inhibition mechanism. The proposed methodology was applied to the AR analysis in soft beverages and powders for gelatine preparation. Colourant concentrations of 63 ± 2 mg/L (n = 3) and 0.30 ± 0.01 mg/g (n = 3) were found, respectively. These results were validated by high performance liquid chromatography technique.
Collapse
Affiliation(s)
- Alicia Coloma
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - María Del Pozo
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain.
| | - Rut Martínez-Moro
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Elías Blanco
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Pedro Atienzar
- Instituto Universitario de Tecnología Química CSIC-UPV, Departamento de Química, Universidad Politécnica de Valencia, 46022 Valencia, Spain
| | - Lorenzo Sánchez
- Departamento de Medio Ambiente, Geología Ambiental Aplicada, CIEMAT, Avda. Complutense, 40 Edif. 85, 28040 Madrid, Spain
| | - María Dolores Petit-Domínguez
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Elena Casero
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| | - Carmen Quintana
- Departamento de Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid, Spain
| |
Collapse
|
43
|
Di Masi S, Laschi S, Pennetta A, Faraoni P, Ranaldi F, De Benedetto GE, Malitesta C. Microfluidic Setup for Simultaneous Separation and Electrochemical Determination of Hg
2+
and Ag
+
Ions in Water. ELECTROANAL 2020. [DOI: 10.1002/elan.202060479] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Sabrina Di Masi
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali University of Salento Via Monteroni 73100 Lecce Italy
| | - Serena Laschi
- Ecobioservices and Researches SrL Via Madonna del Piano 6 50019 Sesto Fiorentino Firenze Italy
| | - Antonio Pennetta
- Dipartimento di Beni Culturali Via per Monteroni 73100 Lecce Italy
| | - Paola Faraoni
- Ecobioservices and Researches SrL Via Madonna del Piano 6 50019 Sesto Fiorentino Firenze Italy
- Laboratorio Congiunto NanoBioSens, Dipartimento di Scienze Biomediche Sperimentali e Cliniche “Mario Serio” Università degli Studi di Firenze Viale Pieraccini 6 50139 Firenze Italy
| | - Francesco Ranaldi
- Laboratorio Congiunto NanoBioSens, Dipartimento di Scienze Biomediche Sperimentali e Cliniche “Mario Serio” Università degli Studi di Firenze Viale Pieraccini 6 50139 Firenze Italy
| | | | - Cosimino Malitesta
- Dipartimento di Scienze e Tecnologie Biologiche ed Ambientali University of Salento Via Monteroni 73100 Lecce Italy
| |
Collapse
|
44
|
Granica M, Tymecki Ł. Prussian Blue (bio)sensing device for distance-based measurements. Anal Chim Acta 2020; 1136:125-133. [PMID: 33081936 DOI: 10.1016/j.aca.2020.08.037] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Revised: 07/23/2020] [Accepted: 08/20/2020] [Indexed: 01/12/2023]
Abstract
In this research, microfluidic paper distance-based systems for the quantification of redox species are proposed. For the preparation of the sensing zone a Prussian Blue (PB) (convertible to Prussian White (PW)) layer was deposited in the channel manufactured by wax-printing technique. According to the chemical properties of PB/PW system, it is possible to develop optical sensors sensitive to both oxidizing and reducing agents. The created systems were evaluated for the determination of ascorbic acid and hydrogen peroxide, which were chosen and used as model analytes. The final versions of the proposed systems exhibited a linear response from 0.25 mmol L-1 to 4.0 and 2.0 mmol L-1 for ascorbic acid and H2O2, respectively. The analytical utility of the paper systems was confirmed by measuring the levels of ascorbic acid in dietary supplements. Results correlation obtained for the described systems and the reference method was over 0.98 (Pearson's R-coefficient). All measurements were characterized by satisfactory reproducibility and acceptable uncertainty (RSD (%) < 6%). Finally, it was demonstrated that the modification of the PW-strip systems with oxidoreductase led to an enzymatic assay for glucose up to 10 mmol L-1 range. Practical utility of the developed bio-strips was confirmed by quantifying glucose in drinks and dietary supplement samples.
Collapse
Affiliation(s)
- Mateusz Granica
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland.
| | - Łukasz Tymecki
- University of Warsaw, Faculty of Chemistry, Pasteur 1, 02-093, Warsaw, Poland
| |
Collapse
|
45
|
Abstract
With the rapid development of high technology, chemical science is not as it used to be a century ago. Many chemists acquire and utilize skills that are well beyond the traditional definition of chemistry. The digital age has transformed chemistry laboratories. One aspect of this transformation is the progressing implementation of electronics and computer science in chemistry research. In the past decade, numerous chemistry-oriented studies have benefited from the implementation of electronic modules, including microcontroller boards (MCBs), single-board computers (SBCs), professional grade control and data acquisition systems, as well as field-programmable gate arrays (FPGAs). In particular, MCBs and SBCs provide good value for money. The application areas for electronic modules in chemistry research include construction of simple detection systems based on spectrophotometry and spectrofluorometry principles, customizing laboratory devices for automation of common laboratory practices, control of reaction systems (batch- and flow-based), extraction systems, chromatographic and electrophoretic systems, microfluidic systems (classical and nonclassical), custom-built polymerase chain reaction devices, gas-phase analyte detection systems, chemical robots and drones, construction of FPGA-based imaging systems, and the Internet-of-Chemical-Things. The technology is easy to handle, and many chemists have managed to train themselves in its implementation. The only major obstacle in its implementation is probably one's imagination.
Collapse
Affiliation(s)
- Gurpur Rakesh D Prabhu
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan.,Department of Applied Chemistry, National Chiao Tung University, 1001 University Road, Hsinchu, 300, Taiwan
| | - Pawel L Urban
- Department of Chemistry, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan.,Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, 101, Section 2, Kuang-Fu Road, Hsinchu, 30013, Taiwan
| |
Collapse
|
46
|
Stamna A, Anthemidis AN. Sequential injection solvent dispersive micro solid phase extraction (SI-SD-μSPE) platform coupled with atomic absorption spectrometry for lead determination in water samples. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104820] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
47
|
Carvalho Soares L, Costa dos Santos C, Cássia Silva Luz R, Santos Damos F. Photoelectrochemical‐assisted Batch Injection Analysis (PEC‐BIA) of Glucose Exploiting Visible LED Light as an Excitation Source. ELECTROANAL 2020. [DOI: 10.1002/elan.201900436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Leonardo Carvalho Soares
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| | | | - Rita Cássia Silva Luz
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| | - Flávio Santos Damos
- Laboratory of Sensors, Devices and Analytical Methods, Department of ChemistryFederal University of Maranhão-UFMA 65080-805 São Luís MA Brazil
| |
Collapse
|
48
|
|
49
|
Mantim T, Chaisiwamongkhol K, Uraisin K, Hauser PC, Wilairat P, Nacapricha D. Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis. Molecules 2020; 25:E2284. [PMID: 32414012 PMCID: PMC7287826 DOI: 10.3390/molecules25102284] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 04/27/2020] [Accepted: 05/07/2020] [Indexed: 01/29/2023] Open
Abstract
This work presents a new dual-purpose detector for photometric and conductivity measurements in flow-based analysis. The photometric detector is a paired emitter-detector diode (PEDD) device, whilst the conductivity detection employs a capacitively coupled contactless conductivity detector (C4D). The flow-through detection cell is a rectangular acrylic block (ca. 2 × 2 × 1.5 cm) with cylindrical channels in Z-configuration. For the PEDD detector, the LED light source and detector are installed inside the acrylic block. The two electrodes of the C4D are silver conducting ink painted on the PEEK inlet and outlet tubing of the Z-flow cell. The dual-purpose detector is coupled with a sequential injection analysis (SIA) system for simultaneous detection of the absorbance of the orange dye and conductivity of the dissolved oral rehydration salt powder. The detector was also used for sequential measurements of creatinine and the conductivity of human urine samples. The creatinine analysis is based on colorimetric detection of the Jaffé reaction using the PEDD detector, and the conductivity of the urine, as measured by the C4D detector, is expressed in millisiemens (mS cm-1).
Collapse
Affiliation(s)
- Thitirat Mantim
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Department of Chemistry, Faculty of Science, Srinakharinwirot University, Sukhumwit 23 Road, Bangkok 10110, Thailand
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Korbua Chaisiwamongkhol
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- School of Science, Mae Fah Luang University, Chiang Rai 57100, Thailand
- Center of Chemical Innovation for Sustainability (CIS), Mae Fah Luang University, Chiang Rai 57100, Thailand
| | - Kanchana Uraisin
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Peter C. Hauser
- Department of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland;
| | - Prapin Wilairat
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- National Doping Control Centre, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| | - Duangjai Nacapricha
- Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Bangkok 10400, Thailand; (K.C.); (K.U.); (P.W.)
- Center of Excellence for Innovation in Chemistry and Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
| |
Collapse
|
50
|
Deroco PB, Medeiros RA, Rocha‐Filho RC, Fatibello‐Filho O. Simple Flow Injection Analysis System Coupled to Multiple‐Pulse Amperometry and a Boron‐Doped Diamond Electrode for the Simultaneous Determination of Sunset Yellow and Aspartame. ChemElectroChem 2020. [DOI: 10.1002/celc.202000365] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Patrícia B. Deroco
- Department of ChemistryUniversidade Federal de São Carlos (UFSCar) C.P. 676 13560-970 São Carlos – SP Brazil
| | - Roberta A. Medeiros
- Department of ChemistryUniversidade Estadual de Londrina (UEL) C.P. 6001 86051-990 Londrina – PR Brazil
| | - Romeu C. Rocha‐Filho
- Department of ChemistryUniversidade Federal de São Carlos (UFSCar) C.P. 676 13560-970 São Carlos – SP Brazil
| | - Orlando Fatibello‐Filho
- Department of ChemistryUniversidade Federal de São Carlos (UFSCar) C.P. 676 13560-970 São Carlos – SP Brazil
| |
Collapse
|