1
|
Porter EB, Adaryan S, Ardebili H, Biswal SL, Verduzco R. Detection of Crude Oil in Subsea Environments Using Organic Electrochemical Transistors. ACS Sens 2024. [PMID: 38954649 DOI: 10.1021/acssensors.4c00700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
Current methods for detecting pipeline oil leaks depend primarily on optical detection, which can be slow and have deployment limitations. An alternative non-optical approach for earlier and faster detection of oil leaks would enable a rapid response and reduce the environmental impact of oil leaks. Here, we demonstrate that organic electrochemical transistors (OECTs) can be used as non-optical sensors for crude oil detection in subsea environments. OECTs are thin film electronic devices that can be used for sensing in a variety of environments, but they have not yet been tested for crude oil detection in subsea environments. We fabricated OECTs with poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) as the channel and showed that coating the channel with a polystyrene film results in an OECT with a large and measurable response to oil. Oil that comes in contact with the device will adsorb onto the polystyrene film and increases the impedance at the electrolyte interface. We performed electrochemical impedance spectroscopy measurements to quantify the impedance across the device and found an optimal thickness for the polystyrene coating for the detection of oil. Under optimal device characteristics, as little as 10 μg of oil adsorbed on the channel surface produced a statistically significant change in the source-drain current. The OECTs were operable in seawater for the detection of oil, and we demonstrated that the devices can be transferred to flexible substrates which can be easily implemented in vehicles, pipelines, or other surfaces. This work demonstrates a low-cost device for oil detection in subsea environments and provides a new application of OECT sensors for sensing.
Collapse
Affiliation(s)
- Erin B Porter
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States
| | - Sarah Adaryan
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States
| | - Haleh Ardebili
- Department of Mechanical Engineering, University of Houston, Houston, Texas 77204, United States
- Materials Science and Engineering Program, University of Houston, Houston, Texas 77204, United States
| | - Sibani Lisa Biswal
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States
| | - Rafael Verduzco
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, Texas 77005, United States
| |
Collapse
|
2
|
Liu H, Song J, Zhao Z, Zhao S, Tian Z, Yan F. Organic Electrochemical Transistors for Biomarker Detections. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024:e2305347. [PMID: 38263718 DOI: 10.1002/advs.202305347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 10/16/2023] [Indexed: 01/25/2024]
Abstract
The improvement of living standards and the advancement of medical technology have led to an increased focus on health among individuals. Detections of biomarkers are feasible approaches to obtaining information about health status, disease progression, and response to treatment of an individual. In recent years, organic electrochemical transistors (OECTs) have demonstrated high electrical performances and effectiveness in detecting various types of biomarkers. This review provides an overview of the working principles of OECTs and their performance in detecting multiple types of biomarkers, with a focus on the recent advances and representative applications of OECTs in wearable and implantable biomarker detections, and provides a perspective for the future development of OECT-based biomarker sensors.
Collapse
Affiliation(s)
- Hong Liu
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Jiajun Song
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Zeyu Zhao
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Sanqing Zhao
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Zhiyuan Tian
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| | - Feng Yan
- Department of Applied Physics, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
- Research Institute of Intelligent Wearable Systems, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, 999077, P. R. China
| |
Collapse
|
3
|
Diacci C, Burtscher B, Berto M, Ruoko TP, Lienemann S, Greco P, Berggren M, Borsari M, Simon DT, Bortolotti CA, Biscarini F. Organic Electrochemical Transistor Aptasensor for Interleukin-6 Detection. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 38141020 DOI: 10.1021/acsami.3c12397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
We demonstrate an organic electrochemical transistor (OECT) biosensor for the detection of interleukin 6 (IL6), an important biomarker associated with various pathological processes, including chronic inflammation, inflammaging, cancer, and severe COVID-19 infection. The biosensor is functionalized with oligonucleotide aptamers engineered to bind specifically IL6. We developed an easy functionalization strategy based on gold nanoparticles deposited onto a poly(3,4-ethylenedioxythiophene) doped with polystyrenesulfonate (PEDOT:PSS) gate electrode for the subsequent electrodeposition of thiolated aptamers. During this functionalization step, the reduction of sulfide bonds allows for simultaneous deposition of a blocking agent. A detection range from picomolar to nanomolar concentrations for IL6 was achieved, and the selectivity of the device was assessed against Tumor Necrosis Factor (TNF), another cytokine involved in the inflammatory processes.
Collapse
Affiliation(s)
- Chiara Diacci
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
- Dipartimento di Scienze della Vita, Università di Modena e Reggio Emilia, via Campi 103, 41125 Modena, Italy
| | - Bernhard Burtscher
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
| | - Marcello Berto
- Dipartimento di Scienze della Vita, Università di Modena e Reggio Emilia, via Campi 103, 41125 Modena, Italy
| | - Tero-Petri Ruoko
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
| | - Samuel Lienemann
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
| | - Pierpaolo Greco
- Department of Neuroscience and Rehabilitation, Università di Ferrara, Via Borsari 46, 44121 Ferrara, Italy
- Center for Translational Neurophysiology of Speech and Communication, Istituto Italiano di Tecnologia, via Fossato di Mortara 17-193, 44100 Ferrara, Italy
| | - Magnus Berggren
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
| | - Marco Borsari
- Dipartimento di Scienze Chimiche e Geologiche, Università di Modena e Reggio Emilia, via Campi 103, 41125 Modena, Italy
| | - Daniel T Simon
- Laboratory of Organic Electronics, Department of Science and Technology, Linköping University, 601 74, Norrköping, Sweden
| | - Carlo A Bortolotti
- Dipartimento di Scienze della Vita, Università di Modena e Reggio Emilia, via Campi 103, 41125 Modena, Italy
| | - Fabio Biscarini
- Dipartimento di Scienze della Vita, Università di Modena e Reggio Emilia, via Campi 103, 41125 Modena, Italy
- Center for Translational Neurophysiology of Speech and Communication, Istituto Italiano di Tecnologia, via Fossato di Mortara 17-193, 44100 Ferrara, Italy
| |
Collapse
|
4
|
Hakimian F, Mazloum-Ardakani M. Ag nanorod@PEI-Ag nanohybrid as an excellent signal label for sensitive and rapid detection of serum HER2. Sci Rep 2023; 13:21792. [PMID: 38066021 PMCID: PMC10709618 DOI: 10.1038/s41598-023-48838-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2023] [Accepted: 11/30/2023] [Indexed: 12/18/2023] Open
Abstract
The accurate detection of Human epidermal growth factor receptor-2 (HER2) as a critical breast cancer biomarker can be essential for the early selection of therapeutic approaches. HER2 is a prominent component of a signaling network. Overexpression of the HER2 protein due to amplification of its gene leads to the development of an aggressive subtype of breast cancer. Patients with tumors that overexpress HER2 are eligible for treatment that significantly reduces mortality rates. Herein, we present a fast and simple method for detecting serum HER2. A new electrochemical label has been developed using charged Ag nanorod@ polyethylenimine-Ag (Ag NR@ PEI-Ag) nanohybrid. The synthesized Ag NR@PEI-Ag nanohybrid simultaneously has the electroactive property of silver and the large surface area of the PEI, which results in the enhancement of the detection signal. So, using Ag NR@PEI-Ag nanohybrid as the electrochemical label, a simple, fast, and sensitive electrochemical biosensor was designed to detect HER2. This way, after immobilizing HER2 aptamer on the Au electrode surface, HER2 or human serum was exposed to the aptamer. Then, the positively charged Ag NR@PEI-Ag nanohybrid was adsorbed onto the negatively charged aptamer-HER2 complex, and the current that was produced due to the Ag/AgCl reaction was measured as the electrochemical signal. The aptasensor shows a broad linear response from 10-12 to 10-7 g, a low detection limit (LOD) of 10 pg, and a total assay time of ~ 30 min.
Collapse
Affiliation(s)
- Fatemeh Hakimian
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, 89195-741, Iran
| | | |
Collapse
|
5
|
Liu J, Kong T, Xiao Y, Bai L, Chen N, Tang H. Organic electrochemical transistor-based immuno-sensor using platinum loaded CeO2 nanosphere-carbon nanotube and zeolitic imidazolate framework-enzyme-metal polyphenol network. Biosens Bioelectron 2023; 230:115236. [PMID: 36989662 DOI: 10.1016/j.bios.2023.115236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/04/2023] [Accepted: 03/16/2023] [Indexed: 03/29/2023]
Abstract
This work demonstrates an organic electrochemical transistor (OECT) immuno-sensor with a detection limit down to fg mL-1. The OECT device transforms the antibody-antigen interaction signal by using the zeolitic imidazolate framework-enzyme-metal polyphenol network nanoprobe, which can produce electro-active substance (H2O2) through the enzyme-catalytic reaction. The produced H2O2 is subsequently electrochemically oxidized at the platinum loaded CeO2 nanosphere-carbon nanotube modified gate electrode, resulting in an amplified current response of the transistor device. This immuno-sensor realizes the selective determination of vascular endothelial growth factor 165 (VEGF165) down to the concentration of 13.6 fg mL-1. It also shows good applicable capacity for determining the VEGF165 that human brain microvascular endothelial cells and U251 human glioblastomas cells secreted in the cell culture medium. The ultrahigh sensitivity of the immuno-sensor is derived from excellent performances of the nanoprobe for enzyme loading and the OECT device for H2O2 detection. This work may provide a general way to fabricate the OECT immuno-sensing device with high performances.
Collapse
|
6
|
Preziosi V, Barra M, Villella VR, Esposito S, D'Angelo P, Marasso SL, Cocuzza M, Cassinese A, Guido S. Immuno-Sensing at Ultra-Low Concentration of TG2 Protein by Organic Electrochemical Transistors. BIOSENSORS 2023; 13:bios13040448. [PMID: 37185523 PMCID: PMC10136445 DOI: 10.3390/bios13040448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/24/2023] [Accepted: 03/29/2023] [Indexed: 05/17/2023]
Abstract
Transglutaminase 2 (TG2) is a ubiquitously expressed member of the transglutaminase family with Ca2+-dependent protein crosslinking activity. Its subcellular localization is crucial in determining its function, and indeed, TG2 is found in the extracellular matrix, mitochondria, recycling endosomes, plasma membrane, cytosol, and nucleus because it is associated with cell growth, differentiation, and apoptosis. It is involved in several pathologies, such as celiac disease, cardiovascular, hepatic, renal, and fibrosis diseases, carrying out opposite functions of up and down regulation in the progression of the same pathology. Therefore, this fine regulation requires a very sensitive and specific method of identification of TG2, which is to be detected in very small quantities in a deregulated condition. Here, we demonstrate the possibility of detecting TG2 down to attomolar concentration by using organic electrochemical transistors driven by gold electrodes functionalized with anti-TG2 antibodies. In particular, a direct correlation between the TG2 concentration and the transistor transconductance values, as extracted from typical transfer curves, was found. Overall, our findings highlight the potentialities of this new biosensing approach for the detection of TG2 in the context of pathological diseases, offering a rapid and cost-effective alternative to traditional methods.
Collapse
Affiliation(s)
- Valentina Preziosi
- Department of Chemical, Materials and Production Engineering, University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
| | - Mario Barra
- CNR-SPIN, c/o Department of Physics "Ettore Pancini", P.le Tecchio, 80, I-80125 Naples, Italy
| | - Valeria Rachela Villella
- Department of Chemical, Materials and Production Engineering, University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
- CEINGE, Advanced Biotechnologies, Via Gaetano Salvatore 486, I-80145 Naples, Italy
| | - Speranza Esposito
- Department of Chemical, Materials and Production Engineering, University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
- CEINGE, Advanced Biotechnologies, Via Gaetano Salvatore 486, I-80145 Naples, Italy
| | | | - Simone Luigi Marasso
- IMEM-CNR, Parco Area delle Scienze 37/A, I-43124 Parma, Italy
- ChiLab, Department of Applied Science and Technology, Politecnico di Torino, I-10129 Torino, Italy
| | - Matteo Cocuzza
- IMEM-CNR, Parco Area delle Scienze 37/A, I-43124 Parma, Italy
- ChiLab, Department of Applied Science and Technology, Politecnico di Torino, I-10129 Torino, Italy
| | - Antonio Cassinese
- CNR-SPIN, c/o Department of Physics "Ettore Pancini", P.le Tecchio, 80, I-80125 Naples, Italy
- Department of Physics "Ettore Pancini", University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
| | - Stefano Guido
- Department of Chemical, Materials and Production Engineering, University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
- CEINGE, Advanced Biotechnologies, Via Gaetano Salvatore 486, I-80145 Naples, Italy
- National Interuniversity Consortium for Materials Science and Technology (INSTM), I-50121 Firenze, Italy
| |
Collapse
|
7
|
Fan J, Parr S, Kang S, Gupta M. Point-of-care (POC) SARS-CoV-2 antigen detection using functionalized aerosol jet-printed organic electrochemical transistors (OECTs). NANOSCALE 2023; 15:5476-5485. [PMID: 36852643 DOI: 10.1039/d2nr06485e] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The continuous spread of coronavirus disease 2019 (COVID-19) has highlighted the need for simple and reliable diagnostic technologies for point-of-care (POC) virus detection applications. Here, we report a COVID-19 diagnostic platform based on aerosol jet-printed antibody-functionalized organic electrochemical transistors (OECTs) for rapidly identifying severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antigens. Selective sensing of SARS-CoV-2 spike S1 protein is achieved in phosphate-buffered saline (PBS) with a detectable range of 1 fg mL-1 to 1 μg mL-1. We used the sensors to detect the antigens in unprocessed patient nasopharyngeal swab samples in universal transport medium (UTM) and achieved an overall accuracy of 70%. In addition, these patient sample tests clearly demonstrate that our OECT threshold voltage shift is correlated with the sample SARS-CoV-2 viral load. Hence, we have demonstrated an accurate POC biosensor for detecting SARS-CoV-2 antigens, which holds great promise towards developing on-site and at-home rapid SARS-CoV-2 infection screening and COVID-19 prognosis.
Collapse
Affiliation(s)
- Jiaxin Fan
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada.
| | - Sheldon Parr
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada.
| | - Seongdae Kang
- Department of Chemical and Materials, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada
| | - Manisha Gupta
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta, T6G 1H9, Canada.
| |
Collapse
|
8
|
Parmeggiani M, Ballesio A, Battistoni S, Carcione R, Cocuzza M, D’Angelo P, Erokhin VV, Marasso SL, Rinaldi G, Tarabella G, Vurro D, Pirri CF. Organic Bioelectronics Development in Italy: A Review. MICROMACHINES 2023; 14:460. [PMID: 36838160 PMCID: PMC9966652 DOI: 10.3390/mi14020460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
In recent years, studies concerning Organic Bioelectronics have had a constant growth due to the interest in disciplines such as medicine, biology and food safety in connecting the digital world with the biological one. Specific interests can be found in organic neuromorphic devices and organic transistor sensors, which are rapidly growing due to their low cost, high sensitivity and biocompatibility. This trend is evident in the literature produced in Italy, which is full of breakthrough papers concerning organic transistors-based sensors and organic neuromorphic devices. Therefore, this review focuses on analyzing the Italian production in this field, its trend and possible future evolutions.
Collapse
Affiliation(s)
- Matteo Parmeggiani
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Alberto Ballesio
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Silvia Battistoni
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Rocco Carcione
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Matteo Cocuzza
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Pasquale D’Angelo
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Victor V. Erokhin
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Simone Luigi Marasso
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Giorgia Rinaldi
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Giuseppe Tarabella
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Davide Vurro
- Camlin Italy Srl, Via Budellungo 2, 43124 Parma, Italy
| | - Candido Fabrizio Pirri
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Center for Sustainable Future Technologies, Italian Institute of Technology, Via Livorno 60, 10144 Turin, Italy
| |
Collapse
|
9
|
Liu J, Tang Y, Cheng Y, Huang W, Xiang L. Electrochemical biosensors based on saliva electrolytes for rapid detection and diagnosis. J Mater Chem B 2022; 11:33-54. [PMID: 36484271 DOI: 10.1039/d2tb02031a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In recent years, electrochemical biosensors (ECBSs) have shown significant potential for real-time disease diagnosis and in situ physical condition monitoring. As a multi-constituent oral fluid comprising various disease signaling biomarkers, saliva has drawn much attention in the field of point-of-care (POC) testing. In particular, during the outbreak of the COVID-19 pandemic, ECBSs which hold the simplicity of a single-step assay compared with the multi-step assay of traditional testing methods are expected to relieve the human and economic burden caused by the massive and long-term sample testing process. Noteworthily, ECBSs for the detection of SARS-CoV-2 in saliva have already been developed and may replace current testing methods. Furthermore, the detection scope has expanded from routine indices such as sugar and uric acid to abnormal biomarkers for early-stage disease detection and drug level monitoring, which further facilitated the evolution of ECBSs in the last 5 years. This review is divided into several main sections. First, we discussed the latest advancements and representative research on ECBSs for saliva testing. Then, we focused on a novel kind of ECBS, organic electrochemical transistors (OECTs), which hold great advantages of high sensitivity and signal-to-noise ratio and on-site detection. Finally, application of ECBSs with integrated portable platforms in oral cavities, which lead to powerful auxiliary testing means for telemedicine, has also been discussed.
Collapse
Affiliation(s)
- Jiayi Liu
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China.
| | - Yufei Tang
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China. .,Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China
| | - Yuhua Cheng
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
| | - Wei Huang
- School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
| | - Lin Xiang
- State Key Laboratory of Oral Diseases & National Clinical Research Centre for Oral Diseases, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China. .,Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, No 14th, 3rd section, Renmin South Road, Chengdu, 610041, China
| |
Collapse
|
10
|
Demuru S, Kim J, El Chazli M, Bruce S, Dupertuis M, Binz PA, Saubade M, Lafaye C, Briand D. Antibody-Coated Wearable Organic Electrochemical Transistors for Cortisol Detection in Human Sweat. ACS Sens 2022; 7:2721-2731. [PMID: 36054907 DOI: 10.1021/acssensors.2c01250] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The dysregulation of the hormone cortisol is related to several pathological states, and its monitoring could help prevent severe stress, fatigue, and mental diseases. While wearable antibody-based biosensors could allow real-time and simple monitoring of antigens, an accurate and low-cost antibody-based cortisol detection through electrochemical methods is considerably challenging due to its low concentration and the high ionic strength of real biofluids. Here, a label-free and fast sensor for cortisol detection is proposed based on antibody-coated organic electrochemical transistors. The developed devices show unprecedented high sensitivities of 50 μA/dec for cortisol sensing in high-ionic-strength solutions with effective cortisol detection demonstrated with real human sweat. The sensing mechanism is analyzed through impedance spectroscopy and confirmed with electrical models. Compared to existing methods requiring bulky and expensive laboratory equipment, these wearable devices enable point-of-care cortisol detection in 5 min with direct sweat collection for personalized well-being monitoring.
Collapse
Affiliation(s)
- Silvia Demuru
- School of Engineering, Ecole Polytechnique Fédérale de Lausanne, Neuchâtel 2000, Switzerland
| | - Jaemin Kim
- School of Engineering, Ecole Polytechnique Fédérale de Lausanne, Neuchâtel 2000, Switzerland
| | - Marwan El Chazli
- School of Engineering, Ecole Polytechnique Fédérale de Lausanne, Neuchâtel 2000, Switzerland
| | - Stephen Bruce
- Clinical Chemistry Laboratory, Centre Hospitalier Universitaire Vaudois, Lausanne 1011, Switzerland
| | - Michael Dupertuis
- Clinical Chemistry Laboratory, Centre Hospitalier Universitaire Vaudois, Lausanne 1011, Switzerland
| | - Pierre-Alain Binz
- Clinical Chemistry Laboratory, Centre Hospitalier Universitaire Vaudois, Lausanne 1011, Switzerland
| | - Mathieu Saubade
- Sports Medicine Unit, Centre Hospitalier Universitaire Vaudois, Lausanne 1011, Switzerland
| | - Céline Lafaye
- Sports Medicine Unit, Centre Hospitalier Universitaire Vaudois, Lausanne 1011, Switzerland
| | - Danick Briand
- School of Engineering, Ecole Polytechnique Fédérale de Lausanne, Neuchâtel 2000, Switzerland
| |
Collapse
|
11
|
Protein Attachment Mechanism for Improved Functionalization of Affinity Monolith Chromatography (AMC). Molecules 2022; 27:molecules27144496. [PMID: 35889369 PMCID: PMC9323659 DOI: 10.3390/molecules27144496] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 07/07/2022] [Accepted: 07/11/2022] [Indexed: 12/10/2022] Open
Abstract
This work aims at understanding the attachment mechanisms and stability of proteins on a chromatography medium to develop more efficient functionalization methodologies, which can be exploited in affinity chromatography. In particular, the study was focused on the understanding of the attachment mechanisms of bovine serum albumin (BSA), used as a ligand model, and protein G on novel amine-modified alumina monoliths as a stationary phase. Protein G was used to develop a column for antibody purification. The results showed that, at lower protein concentrations (i.e., 0.5 to 1.0 mg·mL−1), protein attachment follows a 1st-order kinetics compatible with the presence of covalent binding between the monolith and the protein. At higher protein concentrations (i.e., up to 10 mg·mL−1), the data preferably fit a 2nd-order kinetics. Such a change reflects a different mechanism in the protein attachment which, at higher concentrations, seems to be governed by physical adsorption resulting in a multilayered protein formation, due to the presence of ligand aggregates. The threshold condition for the prevalence of physical adsorption of BSA was found at a concentration higher than 1.0 mg·mL−1. Based on this result, protein concentrations of 0.7 and 1.0 mg·mL−1 were used for the functionalization of monoliths with protein G, allowing a maximum attachment of 1.43 mg of protein G/g of monolith. This column was then used for IgG binding–elution experiments, which resulted in an antibody attachment of 73.5% and, subsequently, elution of 86%, in acidic conditions. This proved the potential of the amine-functionalized monoliths for application in affinity chromatography.
Collapse
|
12
|
Alba-Patiño A, Vaquer A, Barón E, Russell SM, Borges M, de la Rica R. Micro- and nanosensors for detecting blood pathogens and biomarkers at different points of sepsis care. Mikrochim Acta 2022; 189:74. [PMID: 35080669 PMCID: PMC8790942 DOI: 10.1007/s00604-022-05171-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 12/26/2021] [Indexed: 12/29/2022]
Abstract
Severe infections can cause a dysregulated response leading to organ dysfunction known as sepsis. Sepsis can be lethal if not identified and treated right away. This requires measuring biomarkers and pathogens rapidly at the different points where sepsis care is provided. Current commercial approaches for sepsis diagnosis are not fast, sensitive, and/or specific enough for meeting this medical challenge. In this article, we review recent advances in the development of diagnostic tools for sepsis management based on micro- and nanostructured materials. We start with a brief introduction to the most popular biomarkers for sepsis diagnosis (lactate, procalcitonin, cytokines, C-reactive protein, and other emerging protein and non-protein biomarkers including miRNAs and cell-based assays) and methods for detecting bacteremia. We then highlight the role of nano- and microstructured materials in developing biosensors for detecting them taking into consideration the particular needs of every point of sepsis care (e.g., ultrafast detection of multiple protein biomarkers for diagnosing in triage, emergency room, ward, and intensive care unit; quantitative detection to de-escalate treatment; ultrasensitive and culture-independent detection of blood pathogens for personalized antimicrobial therapies; robust, portable, and web-connected biomarker tests outside the hospital). We conclude with an overview of the most utilized nano- and microstructured materials used thus far for solving issues related to sepsis diagnosis and point to new challenges for future development.
Collapse
Affiliation(s)
- Alejandra Alba-Patiño
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Andreu Vaquer
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Department of Chemistry, University of the Balearic Islands, Palma, Spain
| | - Enrique Barón
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain.
| | - Steven M Russell
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
| | - Marcio Borges
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain
- Multidisciplinary Sepsis Unit, ICU, Son Llàtzer University Hospital, Palma, Spain
| | - Roberto de la Rica
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Palma, Spain.
| |
Collapse
|
13
|
Design of a Portable Microfluidic Platform for EGOT-Based in Liquid Biosensing. SENSORS 2022; 22:s22030969. [PMID: 35161715 PMCID: PMC8839715 DOI: 10.3390/s22030969] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/21/2022] [Accepted: 01/25/2022] [Indexed: 01/21/2023]
Abstract
In biosensing applications, the exploitation of organic transistors gated via a liquid electrolyte has increased in the last years thanks to their enormous advantages in terms of sensitivity, low cost and power consumption. However, a practical aspect limiting the use of these devices in real applications is the contamination of the organic material, which represents an obstacle for the realization of a portable sensing platform based on electrolyte-gated organic transistors (EGOTs). In this work, a novel contamination-free microfluidic platform allowing differential measurements is presented and validated through finite element modeling simulations. The proposed design allows the exposure of the sensing electrode without contaminating the EGOT device during the whole sensing tests protocol. Furthermore, the platform is exploited to perform the detection of bovine serum albumin (BSA) as a validation test for the introduced differential protocol, demonstrating the capability to detect BSA at 1 pM concentration. The lack of contamination and the differential measurements provided in this work can be the first steps towards the realization of a reliable EGOT-based portable sensing instrument.
Collapse
|
14
|
Preziosi V, Barra M, Tomaiuolo G, D'Angelo P, Marasso SL, Verna A, Cocuzza M, Cassinese A, Guido S. Organic electrochemical transistors as novel biosensing platforms to study the electrical response of whole blood and plasma. J Mater Chem B 2021; 10:87-95. [PMID: 34870646 DOI: 10.1039/d1tb01584b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
In this paper, for the first time to the best of our knowledge, organic electrochemical transistors are employed to investigate the electrical response of human blood, plasma and alternative buffer solutions that inhibit red blood cell (RBC) aggregation. Our focus is on selecting a suitable electrolytic platform and the related operating conditions, where the RBC effect on the OECT response can be observed separately from the strong ionic environment of plasma in whole blood. The transient response of whole blood to pulse experiments is characterized by two time constants, which can be related to blood viscosity and to the capacitive coupling between the ionic and electronic components of the overall system. The role of capacitive effects, likely due to enhanced double-layer formation by negatively charged RBCs, is also confirmed by the increase of transconductance which was found in RBC suspensions as compared to the suspending buffer. Overall, the complex behavior found in these experiments provides new insights for the development of innovative blood-based sensing devices for biomedical applications.
Collapse
Affiliation(s)
- Valentina Preziosi
- Department of Chemical, Materials and Production Engineering - University Federico II, P.le Tecchio 80, I-80125 Naples, Italy.
| | - Mario Barra
- CNR-SPIN, c/o Department of Physics "Ettore Pancini", P.le Tecchio, 80, I-80125 Napoli, Italy.
| | - Giovanna Tomaiuolo
- Department of Chemical, Materials and Production Engineering - University Federico II, P.le Tecchio 80, I-80125 Naples, Italy.
| | | | - Simone Luigi Marasso
- IMEM-CNR, Parco Area delle Scienze 37/A, I-43124 Parma, Italy.,Chi-Lab, Department of Applied Science and Technology, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy
| | - Alessio Verna
- Chi-Lab, Department of Applied Science and Technology, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy
| | - Matteo Cocuzza
- IMEM-CNR, Parco Area delle Scienze 37/A, I-43124 Parma, Italy.,Chi-Lab, Department of Applied Science and Technology, Politecnico di Torino, C.so Duca degli Abruzzi 24, 10129 Torino, Italy
| | - Antonio Cassinese
- CNR-SPIN, c/o Department of Physics "Ettore Pancini", P.le Tecchio, 80, I-80125 Napoli, Italy. .,Department of Physics "Ettore Pancini", University Federico II, P.le Tecchio 80, I-80125 Naples, Italy
| | - Stefano Guido
- Department of Chemical, Materials and Production Engineering - University Federico II, P.le Tecchio 80, I-80125 Naples, Italy. .,National Interuniversity Consortium for Materials Science and Technology (INSTM), 50121 Firenze, Italy.,CEINGE, Advanced Biotechnologies, 80145 Napoli, Italy
| |
Collapse
|
15
|
Pinheiro T, Cardoso AR, Sousa CEA, Marques AC, Tavares APM, Matos AM, Cruz MT, Moreira FTC, Martins R, Fortunato E, Sales MGF. Paper-Based Biosensors for COVID-19: A Review of Innovative Tools for Controlling the Pandemic. ACS OMEGA 2021; 6:29268-29290. [PMID: 34778604 PMCID: PMC8577188 DOI: 10.1021/acsomega.1c04012] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 10/18/2021] [Indexed: 05/07/2023]
Abstract
The appearance and quick spread of the new severe acute respiratory syndrome coronavirus disease, COVID-19, brought major societal challenges. Importantly, suitable medical diagnosis procedures and smooth clinical management of the disease are an emergent need, which must be anchored on novel diagnostic methods and devices. Novel molecular diagnostic tools relying on nucleic acid amplification testing have emerged globally and are the current gold standard in COVID-19 diagnosis. However, the need for widespread testing methodologies for fast, effective testing in multiple epidemiological scenarios remains a crucial step in the fight against the COVID-19 pandemic. Biosensors have previously shown the potential for cost-effective and accessible diagnostics, finding applications in settings where conventional, laboratorial techniques may not be readily employed. Paper- and cellulose-based biosensors can be particularly relevant in pandemic times, for the renewability, possibility of mass production with sustainable methodologies, and safe environmental disposal. In this review, paper-based devices and platforms targeting SARS-CoV-2 are showcased and discussed, as a means to achieve quick and low-cost PoC diagnosis, including detection methodologies for viral genomic material, viral antigen detection, and serological antibody testing. Devices targeting inflammatory markers relevant for COVID-19 are also discussed, as fast, reliable bedside diagnostic tools for patient treatment and follow-up.
Collapse
Affiliation(s)
- Tomás Pinheiro
- CENIMAT
i3N, Materials Science Department, Faculty of Science and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, Caparica 2829-516, Portugal
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
| | - A. Rita Cardoso
- CENIMAT
i3N, Materials Science Department, Faculty of Science and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, Caparica 2829-516, Portugal
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
- BioMark@ISEP,
School of Engineering, Polytechnic Institute
of Porto, R. Dr. António
Bernardino de Almeida, 431, Porto 4249-015, Portugal
- CEB,
Centre of Biological Engineering, University
of Minho, Braga 4710-057, Portugal
| | - Cristina E. A. Sousa
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
- BioMark@ISEP,
School of Engineering, Polytechnic Institute
of Porto, R. Dr. António
Bernardino de Almeida, 431, Porto 4249-015, Portugal
| | - Ana C. Marques
- CENIMAT
i3N, Materials Science Department, Faculty of Science and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, Caparica 2829-516, Portugal
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
| | - Ana P. M. Tavares
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
- BioMark@ISEP,
School of Engineering, Polytechnic Institute
of Porto, R. Dr. António
Bernardino de Almeida, 431, Porto 4249-015, Portugal
- CEB,
Centre of Biological Engineering, University
of Minho, Braga 4710-057, Portugal
| | - Ana Miguel Matos
- Faculty
of Pharmacy, University of Coimbra, Pólo das Ciências
da Saúde, Azinhaga de Santa Comba, 3000-548 Coimbra, Portugal
- Chemical
Engineering Processes and Forest Products Research Center, Coimbra 3000-548, Portugal
| | - Maria Teresa Cruz
- Faculty
of Medicine, Center for Neuroscience and Cell Biology, University of Coimbra, Rua Larga, Polo I, 1st Floor, Coimbra 3004-504, Portugal
| | - Felismina T. C. Moreira
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
- BioMark@ISEP,
School of Engineering, Polytechnic Institute
of Porto, R. Dr. António
Bernardino de Almeida, 431, Porto 4249-015, Portugal
| | - Rodrigo Martins
- CENIMAT
i3N, Materials Science Department, Faculty of Science and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, Caparica 2829-516, Portugal
| | - Elvira Fortunato
- CENIMAT
i3N, Materials Science Department, Faculty of Science and Technology, Universidade NOVA de Lisboa and CEMOP/UNINOVA, Caparica 2829-516, Portugal
| | - M. Goreti F. Sales
- BioMark@UC,
Faculty of Sciences and Technology, University
of Coimbra R. Sílvio Lima, Pólo II, 3030-790 Coimbra, Portugal
- BioMark@ISEP,
School of Engineering, Polytechnic Institute
of Porto, R. Dr. António
Bernardino de Almeida, 431, Porto 4249-015, Portugal
- CEB,
Centre of Biological Engineering, University
of Minho, Braga 4710-057, Portugal
| |
Collapse
|
16
|
D’Angelo P, Barra M, Lombari P, Coppola A, Vurro D, Tarabella G, Marasso SL, Borriello M, Chianese F, Perna AF, Cassinese A, Ingrosso D. Homocysteine Solution-Induced Response in Aerosol Jet Printed OECTs by Means of Gold and Platinum Gate Electrodes. Int J Mol Sci 2021; 22:11507. [PMID: 34768938 PMCID: PMC8584102 DOI: 10.3390/ijms222111507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 11/16/2022] Open
Abstract
Homocysteine (Hcy) is a non-protein, sulfur-containing amino acid, which is recognized as a possible risk factor for coronary artery and other pathologies when its levels in the blood exceed the normal range of between 5 and 12 μmol/L (hyperhomocysteinemia). At present, standard procedures in laboratory medicine, such as high-performance liquid chromatography (HPLC), are commonly employed for the quantitation of total Hcy (tHcy), i.e., the sum of the protein-bound (oxidized) and free (homocystine plus reduced Hcy) forms, in biological fluids (particularly, serum or plasma). Here, the response of Aerosol Jet-printed organic electrochemical transistors (OECTs), in the presence of either reduced (free) and oxidized Hcy-based solutions, was analyzed. Two different experimental protocols were followed to this end: the former consisting of gold (Au) electrodes' biothiol-induced thiolation, while the latter simply used bare platinum (Pt) electrodes. Electrochemical impedance spectroscopy (EIS) analysis was performed both to validate the gold thiolation protocol and to gain insights into the reduced Hcy sensing mechanism by the Au-gated OECTs, which provided a final limit of detection (LoD) of 80 nM. For the OECT response based on Platinum gate electrodes, on the other hand, a LoD of 180 nM was found in the presence of albumin-bound Hcy, with this being the most abundant oxidized Hcy-form (i.e., the protein-bound form) in physiological fluids. Despite the lack of any biochemical functionalization supporting the response selectivity, the findings discussed in this work highlight the potential role of OECT in the development of low-cost point-of-care (POC) electronic platforms that are suitable for the evaluation, in humans, of Hcy levels within the physiological range and in cases of hyperhomocysteinemia.
Collapse
Affiliation(s)
- Pasquale D’Angelo
- IMEM-CNR, Parco Area delle Scienze 37/A, I 43124 Parma, Italy; (P.D.); (D.V.); (S.L.M.)
| | - Mario Barra
- CNR-SPIN, c/o Dipartimento di Fisica “Ettore Pancini”, P.le Tecchio 80, 80125 Naples, Italy;
| | - Patrizia Lombari
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio 7, 80138 Naples, Italy; (P.L.); (A.C.); (M.B.); (D.I.)
- Department of Translational Medical Science, University of Campania “Luigi Vanvitelli”, via Via Pansini, Bldg., 80131 Naples, Italy
| | - Annapaola Coppola
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio 7, 80138 Naples, Italy; (P.L.); (A.C.); (M.B.); (D.I.)
| | - Davide Vurro
- IMEM-CNR, Parco Area delle Scienze 37/A, I 43124 Parma, Italy; (P.D.); (D.V.); (S.L.M.)
| | | | - Simone Luigi Marasso
- IMEM-CNR, Parco Area delle Scienze 37/A, I 43124 Parma, Italy; (P.D.); (D.V.); (S.L.M.)
| | - Margherita Borriello
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio 7, 80138 Naples, Italy; (P.L.); (A.C.); (M.B.); (D.I.)
| | - Federico Chianese
- Physics Department, University of Naples “Federico II”, P.le Tecchio, 80, 80125 Naples, Italy;
| | - Alessandra F. Perna
- Department of Translational Medical Science, University of Campania “Luigi Vanvitelli”, via Via Pansini, Bldg., 80131 Naples, Italy
| | - Antonio Cassinese
- CNR-SPIN, c/o Dipartimento di Fisica “Ettore Pancini”, P.le Tecchio 80, 80125 Naples, Italy;
- Physics Department, University of Naples “Federico II”, P.le Tecchio, 80, 80125 Naples, Italy;
- Istututo Nazionale di Fisica Nucleare, Sezione di Napoli, P.le Tecchio, 80, 80125 Naples, Italy
| | - Diego Ingrosso
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio 7, 80138 Naples, Italy; (P.L.); (A.C.); (M.B.); (D.I.)
| |
Collapse
|
17
|
Lieberth K, Romele P, Torricelli F, Koutsouras DA, Brückner M, Mailänder V, Gkoupidenis P, Blom PWM. Current-Driven Organic Electrochemical Transistors for Monitoring Cell Layer Integrity with Enhanced Sensitivity. Adv Healthc Mater 2021; 10:e2100845. [PMID: 34309226 DOI: 10.1002/adhm.202100845] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 07/06/2021] [Indexed: 01/28/2023]
Abstract
In this progress report an overview is given on the use of the organic electrochemical transistor (OECT) as a biosensor for impedance sensing of cell layers. The transient OECT current can be used to detect changes in the impedance of the cell layer, as shown by Jimison et al. To circumvent the application of a high gate bias and preventing electrolysis of the electrolyte, in case of small impedance variations, an alternative measuring technique based on an OECT in a current-driven configuration is developed. The ion-sensitivity is larger than 1200 mV V-1 dec-1 at low operating voltage. It can be even further enhanced using an OECT based complementary amplifier, which consists of a p-type and an n-type OECT connected in series, as known from digital electronics. The monitoring of cell layer integrity and irreversible disruption of barrier function with the current-driven OECT is demonstrated for an epithelial Caco-2 cell layer, showing the enhanced ion-sensitivity as compared to the standard OECT configuration. As a state-of-the-art application of the current-driven OECT, the in situ monitoring of reversible tight junction modulation under the effect of drug additives, like poly-l-lysine, is discussed. This shows its potential for in vitro and even in vivo toxicological and drug delivery studies.
Collapse
Affiliation(s)
- Katharina Lieberth
- Max Planck Institute for Polymer Research Ackermannweg 10 Mainz 55128 Germany
| | - Paolo Romele
- Department of Information Engineering University of Brescia Via Branze 38 Brescia 25123 Italy
| | - Fabrizio Torricelli
- Department of Information Engineering University of Brescia Via Branze 38 Brescia 25123 Italy
| | | | - Maximilian Brückner
- Max Planck Institute for Polymer Research Ackermannweg 10 Mainz 55128 Germany
- Dermatology Clinic University Medical Center of the Johannes Gutenberg‐University Mainz Langenbeckstr. 1 Mainz 55131 Germany
| | - Volker Mailänder
- Max Planck Institute for Polymer Research Ackermannweg 10 Mainz 55128 Germany
- Dermatology Clinic University Medical Center of the Johannes Gutenberg‐University Mainz Langenbeckstr. 1 Mainz 55131 Germany
| | | | - Paul W. M. Blom
- Max Planck Institute for Polymer Research Ackermannweg 10 Mainz 55128 Germany
| |
Collapse
|
18
|
Burtscher B, Manco Urbina PA, Diacci C, Borghi S, Pinti M, Cossarizza A, Salvarani C, Berggren M, Biscarini F, Simon DT, Bortolotti CA. Sensing Inflammation Biomarkers with Electrolyte-Gated Organic Electronic Transistors. Adv Healthc Mater 2021; 10:e2100955. [PMID: 34423579 DOI: 10.1002/adhm.202100955] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/16/2021] [Indexed: 01/08/2023]
Abstract
An overview of cytokine biosensing is provided, with a focus on the opportunities provided by organic electronic platforms for monitoring these inflammation biomarkers which manifest at ultralow concentration levels in physiopathological conditions. Specifically, two of the field's state-of-the-art technologies-organic electrochemical transistors (OECTs) and electrolyte gated organic field effect transistors (EGOFETs)-and their use in sensing cytokines and other proteins associated with inflammation are a particular focus. The overview will include an introduction to current clinical and "gold standard" quantification techniques and their limitations in terms of cost, time, and required infrastructure. A critical review of recent progress with OECT- and EGOFET-based protein biosensors is presented, alongside a discussion onthe future of these technologies in the years and decades ahead. This is especially timely as the world grapples with limited healthcare diagnostics during the Coronavirus disease (COVID-19)pandemic where one of the worst-case scenarios for patients is the "cytokine storm." Clearly, low-cost point-of-care technologies provided by OECTs and EGOFETs can ease the global burden on healthcare systems and support professionals by providing unprecedented wealth of data that can help to monitor disease progression in real time.
Collapse
Affiliation(s)
- Bernhard Burtscher
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 60174 Sweden
| | | | - Chiara Diacci
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 60174 Sweden
| | - Simone Borghi
- Department of Life Sciences University of Modena and Reggio Emilia Via Campi 103 Modena 41125 Italy
| | - Marcello Pinti
- Department of Life Sciences University of Modena and Reggio Emilia Via Campi 103 Modena 41125 Italy
| | - Andrea Cossarizza
- Department of Medical and Surgical Sciences for Children and Adults University of Modena and Reggio Emilia Via Campi 287 Modena 41125 Italy
| | - Carlo Salvarani
- Rheumatology Unit University of Modena and Reggio Emilia Medical School Azienda Ospedaliero‐Universitaria Policlinico di Modena Modena 41124 Italy
| | - Magnus Berggren
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 60174 Sweden
| | - Fabio Biscarini
- Department of Life Sciences University of Modena and Reggio Emilia Via Campi 103 Modena 41125 Italy
- Center for Translation Neurophysiology Istituto Italiano di Tecnologia Via Fossato di Mortara 17–19 Ferrara 44100 Italy
| | - Daniel T. Simon
- Laboratory of Organic Electronics Department of Science and Technology Linköping University Norrköping 60174 Sweden
| | - Carlo A. Bortolotti
- Department of Life Sciences University of Modena and Reggio Emilia Via Campi 103 Modena 41125 Italy
| |
Collapse
|
19
|
Barbalinardo M, Bertacchini J, Bergamini L, Magarò MS, Ortolani L, Sanson A, Palumbo C, Cavallini M, Gentili D. Surface properties modulate protein corona formation and determine cellular uptake and cytotoxicity of silver nanoparticles. NANOSCALE 2021; 13:14119-14129. [PMID: 34477693 DOI: 10.1039/d0nr08259g] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Nanoparticles (NPs) have been studied for biomedical applications, ranging from prevention, diagnosis and treatment of diseases. However, the lack of the basic understanding of how NPs interact with the biological environment has severely limited their delivery efficiency to the target tissue and clinical translation. Here, we show the effective regulation of the surface properties of NPs, by controlling the surface ligand density, and their effect on serum protein adsorption, cellular uptake and cytotoxicity. The surface properties of NPs are tuned through the controlled replacement of native ligands, which favor protein adsorption, with ligands capable of increasing protein adsorption resistance. The extent and composition of the protein layer adsorbed on NPs are strongly correlated to the degree of ligands replaced on their surface and, while BSA is the most abundant protein detected, ApoE is the one whose amount is most affected by surface properties. On increasing the protein resistance, cellular uptake and cytotoxicity in mouse embryonic fibroblasts of NPs are drastically reduced, but the surface coating has no effect on the process by which NPs mainly induce cell death. Overall, this study reveals that the tuning of the surface properties of NPs allows us to regulate their biological outcomes by controlling their ability to adsorb serum proteins.
Collapse
Affiliation(s)
- Marianna Barbalinardo
- Consiglio Nazionale delle Ricerche, Istituto per lo Studio dei Materiali Nanostrutturati (CNR-ISMN), via P. Gobetti 101, 40129 Bologna, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Rapid single-molecule detection of COVID-19 and MERS antigens via nanobody-functionalized organic electrochemical transistors. Nat Biomed Eng 2021; 5:666-677. [PMID: 34031558 DOI: 10.1038/s41551-021-00734-9] [Citation(s) in RCA: 155] [Impact Index Per Article: 51.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 04/16/2021] [Indexed: 02/07/2023]
Abstract
The coronavirus disease 2019 (COVID-19) pandemic has highlighted the need for rapid and sensitive protein detection and quantification in simple and robust formats for widespread point-of-care applications. Here, we report on nanobody-functionalized organic electrochemical transistors with a modular architecture for the rapid quantification of single-molecule-to-nanomolar levels of specific antigens in complex bodily fluids. The sensors combine a solution-processable conjugated polymer in the transistor channel and high-density and orientation-controlled bioconjugation of nanobody-SpyCatcher fusion proteins on disposable gate electrodes. The devices provide results after 10 min of exposure to 5 μl of unprocessed samples, maintain high specificity and single-molecule sensitivity in human saliva and serum, and can be reprogrammed to detect any protein antigen if a corresponding specific nanobody is available. We used the sensors to detect green fluorescent protein, and severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and Middle East respiratory syndrome coronavirus (MERS-CoV) spike proteins, and for the COVID-19 screening of unprocessed clinical nasopharyngeal swab and saliva samples with a wide range of viral loads.
Collapse
|
21
|
Interfacing aptamers, nanoparticles and graphene in a hierarchical structure for highly selective detection of biomolecules in OECT devices. Sci Rep 2021; 11:9380. [PMID: 33931690 PMCID: PMC8087810 DOI: 10.1038/s41598-021-88546-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 03/17/2021] [Indexed: 11/09/2022] Open
Abstract
In several biomedical applications, the detection of biomarkers demands high sensitivity, selectivity and easy-to-use devices. Organic electrochemical transistors (OECTs) represent a promising class of devices combining a minimal invasiveness and good signal transduction. However, OECTs lack of intrinsic selectivity that should be implemented by specific approaches to make them well suitable for biomedical applications. Here, we report on a biosensor in which selectivity and a high sensitivity are achieved by interfacing, in an OECT architecture, a novel gate electrode based on aptamers, Au nanoparticles and graphene hierarchically organized to optimize the final response. The fabricated biosensor performs state of the art limit of detection monitoring biomolecules, such as thrombin-with a limit of detection in the picomolar range (≤ 5 pM) and a very good selectivity even in presence of supraphysiological concentrations of Bovine Serum Albumin (BSA-1mM). These accomplishments are the final result of the gate hierarchic structure that reduces sterich indrance that could contrast the recognition events and minimizes false positive, because of the low affinity of graphene towards the physiological environment. Since our approach can be easily applied to a large variety of different biomarkers, we envisage a relevant potential for a large series of different biomedical applications.
Collapse
|
22
|
Adrover-Jaume C, Alba-Patiño A, Clemente A, Santopolo G, Vaquer A, Russell SM, Barón E, González Del Campo MDM, Ferrer JM, Berman-Riu M, García-Gasalla M, Aranda M, Borges M, de la Rica R. Paper biosensors for detecting elevated IL-6 levels in blood and respiratory samples from COVID-19 patients. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 330:129333. [PMID: 33519090 PMCID: PMC7833127 DOI: 10.1016/j.snb.2020.129333] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 12/07/2020] [Accepted: 12/09/2020] [Indexed: 05/05/2023]
Abstract
Decentralizing COVID-19 care reduces contagions and affords a better use of hospital resources. We introduce biosensors aimed at detecting severe cases of COVID-19 in decentralized healthcare settings. They consist of a paper immunosensor interfaced with a smartphone. The immunosensors have been designed to generate intense colorimetric signals when the sample contains ultralow concentrations of IL-6, which has been proposed as a prognosis biomarker of COVID-19. This is achieved by combining a paper-based signal amplification mechanism with polymer-filled reservoirs for dispensing antibody-decorated nanoparticles and a bespoken app for color quantification. With this design we achieved a low limit of detection (LOD) of 10-3 pg mL-1 and semi-quantitative measurements in a wide dynamic range between 10-3 and 102 pg mL-1 in PBS. The assay time is under 10 min. The low LOD allowed us to dilute blood samples and detect IL-6 with an LOD of 1.3 pg mL-1 and a dynamic range up to 102 pg mL-1. Following this protocol, we were able to stratify COVID-19 patients according to different blood levels of IL-6. We also report on the detection of IL-6 in respiratory samples (bronchial aspirate, BAS) from COVID-19 patients. The test could be easily adapted to detect other cytokines such as TNF-α and IL-8 by changing the antibodies decorating the nanoparticles accordingly. The ability of detecting cytokines in blood and respiratory samples paves the way for monitoring local inflammation in the lungs as well as systemic inflammation levels in the body.
Collapse
Affiliation(s)
- Cristina Adrover-Jaume
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- University of the Balearic Islands, Chemistry Department, Cra. de Valldemossa km 7.5, 07122, Palma de Mallorca, Spain
| | - Alejandra Alba-Patiño
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- University of the Balearic Islands, Chemistry Department, Cra. de Valldemossa km 7.5, 07122, Palma de Mallorca, Spain
| | - Antonio Clemente
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - Giulia Santopolo
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- University of the Balearic Islands, Chemistry Department, Cra. de Valldemossa km 7.5, 07122, Palma de Mallorca, Spain
| | - Andreu Vaquer
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - Steven M Russell
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - Enrique Barón
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - María Del Mar González Del Campo
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - Joana M Ferrer
- Immune Response in Human Pathology Group, Health Research Institute of the Balearic Islands (IdISBa), Spain
- Immunology Department, Son Espases University Hospital, Spain Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - María Berman-Riu
- Immune Response in Human Pathology Group, Health Research Institute of the Balearic Islands (IdISBa), Spain
| | - Mercedes García-Gasalla
- Infectious Diseases-HIV Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
| | - María Aranda
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- Multidisciplinary Sepsis Unit, ICU, Son Llàtzer University Hospital, 07198, Palma de Mallorca, Spain
| | - Marcio Borges
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- Multidisciplinary Sepsis Unit, ICU, Son Llàtzer University Hospital, 07198, Palma de Mallorca, Spain
| | - Roberto de la Rica
- Multidisciplinary Sepsis Group, Health Research Institute of the Balearic Islands (IdISBa), Son Espases University Hospital, 07120, Palma de Mallorca, Spain
- University of the Balearic Islands, Chemistry Department, Cra. de Valldemossa km 7.5, 07122, Palma de Mallorca, Spain
| |
Collapse
|
23
|
A novel oriented immunosensor based on AuNPs-thionine-CMWCNTs and staphylococcal protein A for interleukin-6 analysis in complicated biological samples. Anal Chim Acta 2020; 1140:145-152. [DOI: 10.1016/j.aca.2020.10.025] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 09/22/2020] [Accepted: 10/13/2020] [Indexed: 02/07/2023]
|
24
|
Hakimian F, Ghourchian H. Ultrasensitive electrochemical biosensor for detection of microRNA-155 as a breast cancer risk factor. Anal Chim Acta 2020; 1136:1-8. [DOI: 10.1016/j.aca.2020.08.039] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 07/27/2020] [Accepted: 08/19/2020] [Indexed: 12/17/2022]
|
25
|
Jang HJ, Song Y, Wagner J, Katz HE. Suppression of Ionic Doping by Molecular Dopants in Conjugated Polymers for Improving Specificity and Sensitivity in Biosensing Applications. ACS APPLIED MATERIALS & INTERFACES 2020; 12:45036-45044. [PMID: 32924437 DOI: 10.1021/acsami.0c11125] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Ionic doping effects in conjugated polymers often cause nonspecific signaling and a low selectivity of bioelectronic sensing. Using remote-gate field-effect transistor characterization of molecular and ionic doping in poly(3-hexylthiophene) (P3HT) and acid-functionalized polythiophene, poly[3-(3-carboxypropyl) thiophene-2,5-diyl] (PT-COOH), we discovered that proton doping effects on the interfacial potential occurring in P3HT could be suppressed by sequentially doping P3HT by 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ). To be specific, intrinsic pH sensitivity shown by pure P3HT (18 mV/pH in a range from pH 3 to 9) was fully dissipated for doped P3HT:F4TCNQ. However, F4TCNQ sequential doping instead increases pH sensitivity of acid-functionalized polythiophene, PT-COOH (40 mV/pH), compared to that of a pure PT-COOH (30 mV/pH). Interactions between polythiophene backbone and side chains, which constrain the activity of COOH, are weakened by stronger F4TCNQ doping leaving behind responsive COOH groups exposed to aqueous solutions. This is supported by the reduced pH sensitivity of PT-COOH sequentially doped by a weaker dopant, tetracyanoethylene (TCNE) (21 mV/pH). Thus, doping is shown to stabilize a nonpolar conjugated polymer to pH-induced fluctuations on one hand, and to activate a COOH side chain to pH-induced response on the other.
Collapse
Affiliation(s)
- Hyun-June Jang
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218-2608, United States
| | - Yunjia Song
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218-2608, United States
| | - Justine Wagner
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218-2608, United States
| | - Howard E Katz
- Department of Materials Science and Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218-2608, United States
| |
Collapse
|
26
|
Rani D, Singh Y, Salker M, Vu XT, Ingebrandt S, Pachauri V. Point-of-care-ready nanoscale ISFET arrays for sub-picomolar detection of cytokines in cell cultures. Anal Bioanal Chem 2020; 412:6777-6788. [PMID: 32725311 PMCID: PMC7496041 DOI: 10.1007/s00216-020-02820-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 06/21/2020] [Accepted: 07/14/2020] [Indexed: 02/08/2023]
Abstract
Rapid and frequent screening of cytokines as immunomodulation agents is necessary for precise interventions in severe pathophysiological conditions. In addition to high-sensitivity detection of such analytes in complex biological fluids such as blood, saliva, and cell culture medium samples, it is also crucial to work out miniaturized bioanalytical platforms with potential for high-density integration enabling screening of multiple analytes. In this work, we show a compact, point-of-care-ready bioanalytical platform for screening of cytokines such as interleukin-4 (IL-4) and interleukin-2 (IL-2) based on one-dimensional ion-sensitive field-effect transistors arrays (nanoISFETs) of silicon fabricated at wafer-scale via nanoimprint lithography. The nanoISFETs biofunctionalized with receptor proteins alpha IL-4 and alpha IL-2 were deployed for screening cytokine secretion in mouse T helper cell differentiation culture media, respectively. Our nanoISFETs showed robust sensor signals for specific molecular binding and can be readily deployed for real-time screening of cytokines. Quantitative analyses of the nanoISFET-based bioanalytical platform was carried out for IL-4 concentrations ranging from 25 fg/mL (1.92 fM) to 2.5 μg/mL (192 nM), showing a limit of detection down to 3-5 fM, which was found to be in agreement with ELISA results in determining IL-4 concentrations directly in complex cell culture media. Graphical abstract.
Collapse
Affiliation(s)
- Dipti Rani
- Department of Computer Sciences and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482, Zweibruecken, Germany
| | - Yogesh Singh
- Institute of Medical Genetics and Applied Genomics, Eberhard-Karls University Tuebingen, Calwerstraße 7, 72076, Tübingen, Germany
| | - Madhuri Salker
- Women's Hospital, Eberhard-Karls University Tuebingen, Calwerstraße 7/6, 72076, Tübingen, Germany
| | - Xuan Thang Vu
- Department of Computer Sciences and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482, Zweibruecken, Germany
- Institute of Materials in Electrical Engineering 1 (IWE1), RWTH Aachen University, Sommerfeldstrasse 24, 52074, Aachen, Germany
| | - Sven Ingebrandt
- Department of Computer Sciences and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482, Zweibruecken, Germany
- Institute of Materials in Electrical Engineering 1 (IWE1), RWTH Aachen University, Sommerfeldstrasse 24, 52074, Aachen, Germany
| | - Vivek Pachauri
- Department of Computer Sciences and Microsystem Technology, University of Applied Sciences Kaiserslautern, Amerikastrasse 1, 66482, Zweibruecken, Germany.
- Institute of Materials in Electrical Engineering 1 (IWE1), RWTH Aachen University, Sommerfeldstrasse 24, 52074, Aachen, Germany.
| |
Collapse
|
27
|
Rapid prototyping of 3D Organic Electrochemical Transistors by composite photocurable resin. Sci Rep 2020; 10:13335. [PMID: 32770035 PMCID: PMC7414134 DOI: 10.1038/s41598-020-70365-8] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 07/28/2020] [Indexed: 11/28/2022] Open
Abstract
Rapid Prototyping (RP) promises to induce a revolutionary impact on how the objects can be produced and used in industrial manufacturing as well as in everyday life. Over the time a standard technique as the 3D Stereolithography (SL) has become a fundamental technology for RP and Additive Manufacturing (AM), since it enables the fabrication of the 3D objects from a cost-effective photocurable resin. Efforts to obtain devices more complex than just a mere aesthetic simulacre, have been spent with uncertain results. The multidisciplinary nature of such manufacturing technique furtherly hinders the route to the fabrication of complex devices. A good knowledge of the bases of material science and engineering is required to deal with SL technological, characterization and testing aspects. In this framework, our study aims to reveal a new approach to obtain RP of complex devices, namely Organic Electro-Chemical Transistors (OECTs), by SL technique exploiting a resin composite based on the conductive poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and the photo curable Poly(ethylene glycol) diacrylate (PEGDA). A comprehensive study is presented, starting from the optimization of composite resin and characterization of its electrochemical properties, up to the 3D OECTs printing and testing. Relevant performances in biosensing for dopamine (DA) detection using the 3D OECTs are reported and discussed too.
Collapse
|
28
|
Bhasin A, Sanders EC, Ziegler JM, Briggs JS, Drago NP, Attar AM, Santos AM, True MY, Ogata AF, Yoon DV, Majumdar S, Wheat AJ, Patterson SV, Weiss GA, Penner RM. Virus Bioresistor (VBR) for Detection of Bladder Cancer Marker DJ-1 in Urine at 10 pM in One Minute. Anal Chem 2020; 92:6654-6666. [PMID: 32252524 PMCID: PMC7266010 DOI: 10.1021/acs.analchem.0c00534] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
DJ-1, a 20.7 kDa protein, is overexpressed in people who have bladder cancer (BC). Its elevated concentration in urine allows it to serve as a marker for BC. However, no biosensor for the detection of DJ-1 has been demonstrated. Here, we describe a virus bioresistor (VBR) capable of detecting DJ-1 in urine at a concentration of 10 pM in 1 min. The VBR consists of a pair of millimeter-scale gold electrodes that measure the electrical impedance of an ultrathin (≈ 150-200 nm), two-layer polymeric channel. The top layer of this channel (90-105 nm in thickness) consists of an electrodeposited virus-PEDOT (PEDOT is poly(3,4-ethylenedioxythiophene)) composite containing embedded M13 virus particles that are engineered to recognize and bind to the target protein of interest, DJ-1. The bottom layer consists of spin-coated PEDOT-PSS (poly(styrenesulfonate)). Together, these two layers constitute a current divider. We demonstrate here that reducing the thickness of the bottom PEDOT-PSS layer increases its resistance and concentrates the resistance drop of the channel in the top virus-PEDOT layer, thereby increasing the sensitivity of the VBR and enabling the detection of DJ-1. Large signal amplitudes coupled with the inherent simplicity of the VBR sensor design result in high signal-to-noise (S/N > 100) and excellent sensor-to-sensor reproducibility characterized by coefficients of variation in the range of 3-7% across the DJ-1 binding curve down to a concentration of 30 pM, near the 10 pM limit of detection (LOD), encompassing four orders of magnitude in concentration.
Collapse
Affiliation(s)
- Apurva Bhasin
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Emily C Sanders
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Joshua M Ziegler
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Jeffrey S Briggs
- PhageTech Inc., 5 Mason, Suite 170, Irvine, California 92618, United States
| | - Nicholas P Drago
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Aisha M Attar
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Alicia M Santos
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Marie Y True
- PhageTech Inc., 5 Mason, Suite 170, Irvine, California 92618, United States
| | - Alana F Ogata
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Debora V Yoon
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Sudipta Majumdar
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Andrew J Wheat
- Department of Molecular Biology & Biochemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Shae V Patterson
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
- PhageTech Inc., 5 Mason, Suite 170, Irvine, California 92618, United States
| | - Gregory A Weiss
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
- PhageTech Inc., 5 Mason, Suite 170, Irvine, California 92618, United States
- Department of Pharmaceutical Sciences, University of California, Irvine, Irvine, California 92697, United States
- Department of Molecular Biology & Biochemistry, University of California, Irvine, Irvine, California 92697, United States
| | - Reginald M Penner
- Department of Chemistry, University of California, Irvine, Irvine, California 92697, United States
- PhageTech Inc., 5 Mason, Suite 170, Irvine, California 92618, United States
| |
Collapse
|
29
|
Fan J, Zhang S, Li F, Yang Y, Du M. Recent advances in cellulose-based membranes for their sensing applications. CELLULOSE (LONDON, ENGLAND) 2020; 27:9157-9179. [PMID: 32934443 PMCID: PMC7483080 DOI: 10.1007/s10570-020-03445-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 09/07/2020] [Indexed: 05/13/2023]
Abstract
ABSTRACT In recent years, sensing applications have played a very important role in various fields. As a novel natural material, cellulose-based membranes with many merits can be served as all kinds of sensors. This review summarizes the recent progress of cellulose membranes as sensors, mainly focusing on their preparation processes and sensing properties. In addition, the opportunities and challenges of cellulose membrane-based sensors are also prospected. This review provides some references for the design of cellulose membrane materials for sensing applications in the future.
Collapse
Affiliation(s)
- Jiang Fan
- Shaanxi Provincial Key Laboratory of Papermaking Technology and Specialty Paper Development, National Demonstration Center for Experimental Light Chemistry Engineering Education, Key Laboratory of Paper Based Functional Materials of China National Light Industry, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Sufeng Zhang
- Shaanxi Provincial Key Laboratory of Papermaking Technology and Specialty Paper Development, National Demonstration Center for Experimental Light Chemistry Engineering Education, Key Laboratory of Paper Based Functional Materials of China National Light Industry, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Fei Li
- The Second Kindergarten, Economic and Technological Development Zone, Xi’an, 710021 People’s Republic of China
| | - Yonglin Yang
- School of Environmental Science and Engineering, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| | - Min Du
- Shaanxi Provincial Key Laboratory of Papermaking Technology and Specialty Paper Development, National Demonstration Center for Experimental Light Chemistry Engineering Education, Key Laboratory of Paper Based Functional Materials of China National Light Industry, Shaanxi University of Science and Technology, Xi’an, 710021 People’s Republic of China
| |
Collapse
|
30
|
Decataldo F, Barbalinardo M, Gentili D, Tessarolo M, Calienni M, Cavallini M, Fraboni B. Organic Electrochemical Transistors for Real‐Time Monitoring of In Vitro Silver Nanoparticle Toxicity. ACTA ACUST UNITED AC 2019; 4:e1900204. [DOI: 10.1002/adbi.201900204] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Revised: 10/11/2019] [Indexed: 12/30/2022]
Affiliation(s)
- Francesco Decataldo
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Marianna Barbalinardo
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Denis Gentili
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Marta Tessarolo
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Maria Calienni
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| | - Massimiliano Cavallini
- Consiglio Nazionale delle RicercheIstituto per lo Studio dei Materiali Nanostrutturati (CNR‐ISMN) via P. Gobetti 101 40129 Bologna Italy
| | - Beatrice Fraboni
- Department of Physics and AstronomyAlma Mater Studiorum – University of Bologna Viale Berti Pichat 6/2 40127 Bologna Italy
| |
Collapse
|
31
|
Parmeggiani M, Verna A, Ballesio A, Cocuzza M, Piatti E, Fra V, Pirri CF, Marasso SL. P3HT Processing Study for In-Liquid EGOFET Biosensors: Effects of the Solvent and the Surface. SENSORS (BASEL, SWITZERLAND) 2019; 19:E4497. [PMID: 31627267 PMCID: PMC6832883 DOI: 10.3390/s19204497] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 10/11/2019] [Accepted: 10/14/2019] [Indexed: 12/02/2022]
Abstract
In-liquid biosensing is the new frontier of health and environment monitoring. A growing number of analytes and biomarkers of interest correlated to different diseases have been found, and the miniaturized devices belonging to the class of biosensors represent an accurate and cost-effective solution to obtaining their recognition. In this study, we investigate the effect of the solvent and of the substrate modification on thin films of organic semiconductor Poly(3-hexylthiophene) (P3HT) in order to improve the stability and electrical properties of an Electrolyte Gated Organic Field Effect Transistor (EGOFET) biosensor. The studied surface is the relevant interface between the P3HT and the electrolyte acting as gate dielectric for in-liquid detection of an analyte. Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS) characterizations were employed to study the effect of two solvents (toluene and 1,2-dichlorobenzene) and of a commercial adhesion promoter (Ti Prime) on the morphological structure and electronic properties of P3HT film. Combining the results from these surface characterizations with electrical measurements, we investigate the changes on the EGOFET performances and stability in deionized (DI) water with an Ag/AgCl gate electrode.
Collapse
Affiliation(s)
- Matteo Parmeggiani
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
- Istituto Italiano di Tecnologia, Center for Sustainable Future Technologies, Via Livorno 60, 10144 Torino, Italy.
| | - Alessio Verna
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
| | - Alberto Ballesio
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
| | - Matteo Cocuzza
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| | - Erik Piatti
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
| | - Vittorio Fra
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
| | - Candido Fabrizio Pirri
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
- Istituto Italiano di Tecnologia, Center for Sustainable Future Technologies, Via Livorno 60, 10144 Torino, Italy.
| | - Simone Luigi Marasso
- Department of Applied Science and Technology (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Torino, Italy.
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| |
Collapse
|
32
|
Paterson AF, Faber H, Savva A, Nikiforidis G, Gedda M, Hidalgo TC, Chen X, McCulloch I, Anthopoulos TD, Inal S. On the Role of Contact Resistance and Electrode Modification in Organic Electrochemical Transistors. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1902291. [PMID: 31343087 DOI: 10.1002/adma.201902291] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/23/2019] [Indexed: 06/10/2023]
Abstract
Contact resistance is renowned for its unfavorable impact on transistor performance. Despite its notoriety, the nature of contact resistance in organic electrochemical transistors (OECTs) remains unclear. Here, by investigating the role of contact resistance in n-type OECTs, the first demonstration of source/drain-electrode surface modification for achieving state-of-the-art n-type OECTs is reported. Specifically, thiol-based self-assembled monolayers (SAMs), 4-methylbenzenethiol (MBT) and pentafluorobenzenethiol (PFBT), are used to investigate contact resistance in n-type accumulation-mode OECTs made from the hydrophilic copolymer P-90, where the deliberate functionalization of the gold source/drain electrodes decreases and increases the energetic mismatch at the electrode/semiconductor interface, respectively. Although MBT treatment is found to increase the transconductance three-fold, contact resistance is not found to be the dominant factor governing OECT performance. Additional morphology and surface energy investigations show that increased performance comes from SAM-enhanced source/drain electrode surface energy, which improves wetting, semiconductor/metal interface quality, and semiconductor morphology at the electrode and channel. Overall, contact resistance in n-type OECTs is investigated, whilst identifying source/drain electrode treatment as a useful device engineering strategy for achieving state of the art n-type OECTs.
Collapse
Affiliation(s)
- Alexandra F Paterson
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Hendrik Faber
- Division of Physical Sciences and Engineering, KAUST Solar Centre, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Achilleas Savva
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Georgios Nikiforidis
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Murali Gedda
- Division of Physical Sciences and Engineering, KAUST Solar Centre, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Tania C Hidalgo
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Xingxing Chen
- Division of Physical Sciences and Engineering, KAUST Solar Centre, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Iain McCulloch
- Division of Physical Sciences and Engineering, KAUST Solar Centre, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
- Department of Chemistry and Centre for Plastic Electronics, Imperial College London, South Kensington, London, SW7 2AZ, UK
| | - Thomas D Anthopoulos
- Division of Physical Sciences and Engineering, KAUST Solar Centre, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| | - Sahika Inal
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology, Thuwal, 23955-6900, Saudi Arabia
| |
Collapse
|
33
|
Chen X, Dong T, Wei X, Yang Z, Matos Pires NM, Ren J, Jiang Z. Electrochemical methods for detection of biomarkers of Chronic Obstructive Pulmonary Disease in serum and saliva. Biosens Bioelectron 2019; 142:111453. [PMID: 31295711 DOI: 10.1016/j.bios.2019.111453] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Revised: 06/07/2019] [Accepted: 06/19/2019] [Indexed: 02/02/2023]
Abstract
Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of death nowadays, and its underdiagnosis is still a great challenge. More effective diagnosis method is in urgent need since the traditional spirometry has many limitations in the practical application. The electrochemical (EC) detection methods have their unique advantages of high accuracy, short response time and easy integration of the system. In this review, recent works on the EC methods for COPD biomarkers including interleukin 6 (IL-6), interleukin 8 (IL-8) and C-reactive protein (CRP) are summarized. Five types of EC methods are highlighted in this study, as enzyme-labelled immunosensors, nanoparticle-labelled immunosensors, capacitive or impedimetric immunosensors, magnetoimmunosensors, and field effect transistor (FET) immunosensors. To date, EC immunosensors have been exhibiting high analytical performance with a detection limit that can achieve several pg/mL or even lower. The simplicity of EC immunosensors makes them a perfect solution for a future point-of-care device to use in settings for COPD diagnosis and follow-up. Nevertheless, more efforts need to be paid on the simultaneous detection of multiple biomarkers, a demand for the clinical diagnosis, and processes of assay simplification towards achieving one-step detection.
Collapse
Affiliation(s)
- Xuan Chen
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, National Research Base of Intelligent Manufacturing Service, School of Computer Science and Information Engineering, Chongqing Technology and Business University, Nan'an District, Chongqing, 400067, China; State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049, China; Department of Microsystems (IMS), Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway, Postboks 235, 3603, Kongsberg, Norway
| | - Tao Dong
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, National Research Base of Intelligent Manufacturing Service, School of Computer Science and Information Engineering, Chongqing Technology and Business University, Nan'an District, Chongqing, 400067, China; Department of Microsystems (IMS), Faculty of Technology, Natural Sciences and Maritime Sciences, University of South-Eastern Norway, Postboks 235, 3603, Kongsberg, Norway.
| | - Xueyong Wei
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, National Research Base of Intelligent Manufacturing Service, School of Computer Science and Information Engineering, Chongqing Technology and Business University, Nan'an District, Chongqing, 400067, China
| | - Nuno Miguel Matos Pires
- Chongqing Key Laboratory of Micro-Nano Systems and Smart Transduction, Collaborative Innovation Center on Micro-Nano Transduction and Intelligent Eco-Internet of Things, Chongqing Key Laboratory of Colleges and Universities on Micro-Nano Systems Technology and Smart Transducing, National Research Base of Intelligent Manufacturing Service, School of Computer Science and Information Engineering, Chongqing Technology and Business University, Nan'an District, Chongqing, 400067, China
| | - Juan Ren
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Zhuangde Jiang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| |
Collapse
|
34
|
Bai L, Elósegui CG, Li W, Yu P, Fei J, Mao L. Biological Applications of Organic Electrochemical Transistors: Electrochemical Biosensors and Electrophysiology Recording. Front Chem 2019; 7:313. [PMID: 31134185 PMCID: PMC6514146 DOI: 10.3389/fchem.2019.00313] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 04/18/2019] [Indexed: 12/21/2022] Open
Abstract
Organic electrochemical transistors (OECTs) are recently developed high-efficient transducers not only for electrochemical biosensor but also for cell electrophysiological recording due to the separation of gate electrode from the transistor device. The efficient integration of OECTs with electrochemical gate electrode makes the as-prepared sensors with improved performance, such as sensitivity, limit of detection, and selectivity. We herein reviewed the recent progress of OECTs-based biosensors and cell electrophysiology recording, mainly focusing on the principle and chemical design of gate electrode and the channel. First, the configuration, work principle, semiconductor of OECT are briefly introduced. Then different kinds of sensing modes are reviewed, especially for the biosensing and electrophysiological recording. Finally, the challenges and opportunities of this research field are discussed.
Collapse
Affiliation(s)
- Liming Bai
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, China
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
| | - Cristina García Elósegui
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Weiqi Li
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Ping Yu
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| | - Junjie Fei
- Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, College of Chemistry, Xiangtan University, Xiangtan, China
| | - Lanqun Mao
- Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, The Chinese Academy of Sciences, Beijing, China
- School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, China
| |
Collapse
|
35
|
Liao J, Si H, Zhang X, Lin S. Functional Sensing Interfaces of PEDOT:PSS Organic Electrochemical Transistors for Chemical and Biological Sensors: A Mini Review. SENSORS (BASEL, SWITZERLAND) 2019; 19:E218. [PMID: 30634408 PMCID: PMC6359468 DOI: 10.3390/s19020218] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 12/29/2018] [Accepted: 01/05/2019] [Indexed: 02/04/2023]
Abstract
Organic electrochemical transistors (OECTs) are promising devices for applications in in vitro and in vivo measurements. OECTs have two important sensing interfaces for signal monitoring: One is the gate electrode surface; the other is the channel surface. This mini review introduced the new developments in chemical and biological detection of the two sensing interfaces. Specific focus was given on the modification technological approaches of the gate or channel surface. In particular, some unique strategies and surface designs aiming to facilitate signal-transduction and amplification were discussed. Several perspectives and current challenges of OECTs development were also briefly summarized.
Collapse
Affiliation(s)
- Jianjun Liao
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Ecology and Environment, Hainan University, Haikou 570228, China.
| | - Hewei Si
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| | - Xidong Zhang
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| | - Shiwei Lin
- State Key Laboratory of Marine Resource Utilization in South China Sea, Hainan University, Haikou 570228, China.
- College of Materials and Chemical Engineering, Hainan University, Haikou 570228, China.
| |
Collapse
|
36
|
D'Angelo P, Tarabella G, Romeo A, Marasso SL, Verna A, Cocuzza M, Peruzzi C, Vurro D, Iannotta S. PEDOT:PSS Morphostructure and Ion-To-Electron Transduction and Amplification Mechanisms in Organic Electrochemical Transistors. MATERIALS (BASEL, SWITZERLAND) 2018; 12:E9. [PMID: 30577510 PMCID: PMC6337112 DOI: 10.3390/ma12010009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2018] [Revised: 11/29/2018] [Accepted: 12/14/2018] [Indexed: 11/29/2022]
Abstract
Organic electrochemical transistors (OECTs) represent a powerful and versatile type of organic-based device, widely used in biosensing and bioelectronics due to potential advantages in terms of cost, sensitivity, and system integration. The benchmark organic semiconductor they are based on is poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS), the electrical properties of which are reported to be strongly dependent on film morphology and structure. In particular, the literature demonstrates that film processing induces morphostructural changes in terms of conformational rearrangements in the PEDOT:PSS in-plane phase segregation and out-of-plane vertical separation between adjacent PEDOT-rich domains. Here, taking into account these indications, we show the thickness-dependent operation of OECTs, contextualizing it in terms of the role played by PEDOT:PSS film thickness in promoting film microstructure tuning upon controlled-atmosphere long-lasting thermal annealing (LTA). To do this, we compared the LTA-OECT response to that of OECTs with comparable channel thicknesses that were exposed to a rapid thermal annealing (RTA). We show that the LTA process on thicker films provided OECTs with an enhanced amplification capability. Conversely, on lower thicknesses, the LTA process induced a higher charge carrier modulation when the device was operated in sensing mode. The provided experimental characterization also shows how to optimize the OECT response by combining the control of the microstructure via solution processing and the effect of postdeposition processing.
Collapse
Affiliation(s)
- Pasquale D'Angelo
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| | | | - Agostino Romeo
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| | - Simone Luigi Marasso
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
- Chilab, Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d'Armi 6, 10034 Chivasso (Torino), Italy.
| | - Alessio Verna
- Chilab, Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d'Armi 6, 10034 Chivasso (Torino), Italy.
| | - Matteo Cocuzza
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
- Chilab, Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d'Armi 6, 10034 Chivasso (Torino), Italy.
| | - Carlotta Peruzzi
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| | - Davide Vurro
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| | - Salvatore Iannotta
- Istituto dei Materiali per l'Elettronica ed il Magnetismo, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy.
| |
Collapse
|