1
|
Sihota P, Yadav RN, Poleboina S, Mehandia V, Bhadada SK, Tikoo K, Kumar N. Development of HFD-Fed/Low-Dose STZ-Treated Female Sprague-Dawley Rat Model to Investigate Diabetic Bone Fragility at Different Organization Levels. JBMR Plus 2020; 4:e10379. [PMID: 33103024 PMCID: PMC7574700 DOI: 10.1002/jbm4.10379] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 05/31/2020] [Indexed: 01/11/2023] Open
Abstract
Type 2 diabetes (T2D) adversely affects the normal functioning, intrinsic material properties, and structural integrity of many tissues, and bone fragility is one of them. To simulate human T2D and to investigate diabetic bone fragility, many rodent diabetic models have been developed. Still, an outbred genetically normal nonobese diabetic rat model is not available that can better simulate the disease characteristics of nonobese T2D patients, who have a high prevalence in Asia. In this study, we used a combination treatment of high-fat diet (4 weeks, 58% kcal as fat) and low-dose streptozotocin (STZ; 35 mg/kg i.p. at the end of the fourth week) to develop T2D in female Sprague-Dawley (SD) rats. After 8 weeks of the establishment of the T2D model, the femoral bones were excised after euthanizing rats (animal age approximately 21 to 22 weeks; n = 10 with T2D, n = 10 without diabetes). The bone microstructure (μCT), mechanical, and material properties (three-point bending, cyclic reference point indentation, nanoindentation), mean mineral crystallite size (XRD), bone composition (mineral-to-matrix ratio, nonenzymatic cross-link ratio [NE-xLR], Fourier transform-infrared microspectroscopy), and total fluorescent advanced glycation end products were analyzed. We found that diabetic bone had reduced whole-bone strength and compromised structural properties (μCT). The NE-xLRs were elevated in the T2D group, and strongly and negatively correlated with postyield displacement, which suggests bone fragility was caused by a lack of glycation control. Along with that, the decreased mineral-to-matrix ratio and modulus, increased indentation distance increase, and wider mineral crystallite size in the T2D group were evidence that the diabetic bone composition and material properties had changed, and bone became weaker with a tendency to easily fracture. Altogether, this model simulates the natural history and metabolic characteristics of late-stage T2D (insulin resistance and as disease progress develops, hypoinsulinemia) for nonobese young (and/or adolescent) T2D patients (Asians) and provides potential evidence of diabetic bone fragility at various organization levels. © 2020 The Authors. JBMR Plus published by Wiley Periodicals, Inc. on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Praveer Sihota
- Department of Mechanical EngineeringIndian Institute of Technology RoparRupnagarIndia
| | - Ram Naresh Yadav
- Department of Mechanical EngineeringIndian Institute of Technology RoparRupnagarIndia
| | - Sumathi Poleboina
- Department of Pharmacology and ToxicologyNational Institute of Pharmaceutical Education and ResearchMohaliIndia
| | - Vishwajeet Mehandia
- Department of Mechanical EngineeringIndian Institute of Technology RoparRupnagarIndia
| | - Sanjay Kumar Bhadada
- Department of EndocrinologyPost Graduate Institute of Medical Education and ResearchChandigarhIndia
| | - Kulbhushan Tikoo
- Department of Pharmacology and ToxicologyNational Institute of Pharmaceutical Education and ResearchMohaliIndia
| | - Navin Kumar
- Department of Mechanical EngineeringIndian Institute of Technology RoparRupnagarIndia
| |
Collapse
|
2
|
Rezaee T, Bouxsein ML, Karim L. Increasing fluoride content deteriorates rat bone mechanical properties. Bone 2020; 136:115369. [PMID: 32320892 PMCID: PMC7246161 DOI: 10.1016/j.bone.2020.115369] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Revised: 04/16/2020] [Accepted: 04/17/2020] [Indexed: 02/06/2023]
Abstract
Elevation of bone fluoride levels due to drinking beverages with high fluoride content or other means such as inhalation can result in skeletal fluorosis and lead to increased joint pain, skeletal deformities, and fracture. Because skeletal fluorosis alters bone's mineral composition, it is likely to affect bone's tissue-level mechanical properties with consequent effects on whole bone mechanical behavior. To investigate this, we determined whether incubation with in vitro sodium fluoride (NaF) altered bone's mechanical behavior at both the tissue- and whole bone-levels using cyclic reference point indentation (cRPI) and traditional 3-point bending, respectively. Forty-two ulnas from female adult rats (5-6 months) were randomly divided into 5 groups (vehicle, 0.05 M NaF, 0.25 M NaF, 0.75 M NaF, and 1.5 M NaF). Bones were washed in a detergent solution to remove organic barriers to ion exchange and incubated in respective treatment solutions (12 h, 23 °C). Cortical tissue mineral density (TMD) and geometry at the mid-diaphysis were determined by microCT. cRPI was performed on the distal diaphysis (9 N, 2 Hz, 10 cycles), and then bones were tested in 3-point bending to assess whole bone mechanical properties. The incubations in vehicle (0 M) up to 1.5 M in vitro NaF concentrations achieved bone fluoride levels ranging from approximately 0.70 to 15.8 ppm. NaF-incubated bones had significantly greater indentation distances, higher displacement-to-maximum force, and lower estimated elastic modulus, ultimate stress, and bending rigidity with increasing NaF concentration compared to vehicle-incubated bones. cRPI variables were moderately correlated to whole bone mechanical properties such that higher indentation distances were associated with lower estimated elastic modulus, ultimate stress, and bending rigidity. In conclusion, in vitro NaF incubation mostly has a deleterious effect on bone mechanical behavior with increasing NaF levels that is independent of bone turnover and reflected, in part, by less resistance of the tissue to cRPI-based indentation.
Collapse
Affiliation(s)
- Taraneh Rezaee
- Department of Bioengineering, University of Massachusetts Dartmouth, 285 Old Westport Road, Dartmouth, MA 02747, USA.
| | - Mary L Bouxsein
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115, USA.
| | - Lamya Karim
- Department of Bioengineering, University of Massachusetts Dartmouth, 285 Old Westport Road, Dartmouth, MA 02747, USA.
| |
Collapse
|
3
|
Schoeb M, Hamdy NAT, Malgo F, Winter EM, Appelman-Dijkstra NM. Added Value of Impact Microindentation in the Evaluation of Bone Fragility: A Systematic Review of the Literature. Front Endocrinol (Lausanne) 2020; 11:15. [PMID: 32117052 PMCID: PMC7020781 DOI: 10.3389/fendo.2020.00015] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 01/09/2020] [Indexed: 12/22/2022] Open
Abstract
The current gold standard for the diagnosis of osteoporosis and the prediction of fracture risk is the measurement of bone mineral density (BMD) using dual energy x-ray absorptiometry (DXA). A low BMD is clearly associated with increased fracture risk, but BMD is not the only determinant of bone strength, particularly in secondary osteoporosis and metabolic bone disorders in which components other than BMD are affected and DXA often underestimates true fracture risk. Material properties of bone which significantly contribute to bone strength have become evaluable in vivo with the impact microindentation (IMI) technique using the OsteoProbe® device. The question arises whether this new tool is of added value in the evaluation of bone fragility. To this effect, we conducted a systematic review of all clinical studies using IMI in vivo in humans also addressing practical aspects of the technique and differences in study design, which may impact outcome. Search data generated 38 studies showing that IMI can identify patients with primary osteoporosis and fractures, patients with secondary osteoporosis due to various underlying systemic disorders, and scarce longitudinal data also show that this tool can detect changes in bone material strength index (BMSi), following bone-modifying therapy including use of corticosteroids. However, this main outcome parameter was not always concordant between studies. This systematic review also identified a number of factors that impact on BMSi outcome. These include subject- and disease-related factors such as the relationship between BMSi and age, geographical region and the presence of fractures, and technique- and operator-related factors. Taken together, findings from this systematic review confirm the added value of IMI for the evaluation and follow-up of elements of bone fragility, particularly in secondary osteoporosis. Notwithstanding, the high variability of BMSi outcome between studies calls for age-dependent reference values, and for the harmonization of study protocols. Prospective multicenter trials using standard operating procedures are required to establish the value of IMI in the prediction of future fracture risk, before this technique is introduced in routine clinical practice.
Collapse
|
4
|
Modeling of Osteoprobe indentation on bone. J Mech Behav Biomed Mater 2019; 90:365-373. [DOI: 10.1016/j.jmbbm.2018.09.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 09/02/2018] [Accepted: 09/24/2018] [Indexed: 12/27/2022]
|
5
|
Chang A, Easson GW, Tang SY. Clinical measurements of bone tissue mechanical behavior using reference point indentation. Clin Rev Bone Miner Metab 2018; 16:87-94. [PMID: 30983912 DOI: 10.1007/s12018-018-9249-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Over the last thirty years, it has become increasingly clear the amount of bone (e.g. 'bone quantity') and the quality of the bone matrix (e.g. 'bone quality') both critically contribute to bone's tissue-level mechanical behavior and the subsequent ability of bone to resist fracture. Although determining the tissue-level mechanical behavior of bone through mechanical testing is relatively straightforward in the laboratory, the destructive nature of such testing is unfeasible in humans and in animal models requiring longitudinal observation. Therefore, surrogate measurements are necessary for quantifying tissue-level mechanical behavior for the pre-clinical and clinical evaluation of bone strength and fracture risk in vivo. A specific implementation of indentation known as reference point indentation (RPI) enables the mechanical testing of bone tissue without the need to excise and prepare the bone surface. However, this compromises the ability to carefully control the specimen geometry that is required to define the bone tissue material properties. Yet the versatility of such measurements in clinical populations is provocative, and to date there are a number of promising studies that have utilized this tool to discern bone pathologies and to monitor the effects of therapeutics on bone quality. Concurrently, on-going efforts continue to investigate the aspects of bone material behavior measured by RPI, and the compositional factors that contribute to these measurements. There are currently two variants, cyclic- and impact- RPI, that have been utilized in pre-clinical and clinical studies. This review surveys clinical studies that utilize RPI, with particular emphasis on the clinical instrument, as well as the endeavors to understand the fundamental mechanisms of such measurements. Ultimately, an improved awareness in the tradeoffs and limitations of in vivo RPI is critical towards the effective and successful utilization of this tool for the overall improvement of fragility determination in the clinic.
Collapse
Affiliation(s)
- Andrew Chang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO
| | - Garrett W Easson
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO
| | - Simon Y Tang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO
| |
Collapse
|
6
|
Bailey S, Vashishth D. Mechanical Characterization of Bone: State of the Art in Experimental Approaches-What Types of Experiments Do People Do and How Does One Interpret the Results? Curr Osteoporos Rep 2018; 16:423-433. [PMID: 29915968 PMCID: PMC8078087 DOI: 10.1007/s11914-018-0454-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
PURPOSE OF REVIEW The mechanical integrity of bone is determined by the direct measurement of bone mechanical properties. This article presents an overview of the current, most common, and new and upcoming experimental approaches for the mechanical characterization of bone. The key outcome variables of mechanical testing, as well as interpretations of the results in the context of bone structure and biology are also discussed. RECENT FINDINGS Quasi-static tests are the most commonly used for determining the resistance to structural failure by a single load at the organ (whole bone) level. The resistance to crack initiation or growth by fracture toughness testing and fatigue loading offers additional and more direct characterization of tissue material properties. Non-traditional indentation techniques and in situ testing are being increasingly used to probe the material properties of bone ultrastructure. Destructive ex vivo testing or clinical surrogate measures are considered to be the gold standard for estimating fracture risk. The type of mechanical test used for a particular investigation depends on the length scale of interest, where the outcome variables are influenced by the interrelationship between bone structure and composition. Advancement in the sensitivity of mechanical characterization techniques to detect changes in bone at the levels subjected to modifications by aging, disease, and/or pharmaceutical treatment is required. As such, a number of techniques are now available to aid our understanding of the factors that contribute to fracture risk.
Collapse
Affiliation(s)
- Stacyann Bailey
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
| | - Deepak Vashishth
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA.
| |
Collapse
|
7
|
Rolvien T, Schmidt FN, Milovanovic P, Jähn K, Riedel C, Butscheidt S, Püschel K, Jeschke A, Amling M, Busse B. Early bone tissue aging in human auditory ossicles is accompanied by excessive hypermineralization, osteocyte death and micropetrosis. Sci Rep 2018; 8:1920. [PMID: 29382878 PMCID: PMC5789841 DOI: 10.1038/s41598-018-19803-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 01/09/2018] [Indexed: 01/20/2023] Open
Abstract
Within the mineralized bone, osteocytes form a multifunctional mechanosensitive network orchestrating bone remodelling. A preserved osteocyte population is a crucial determinant of bone quality. In human auditory ossicles, the early decrease in osteocyte numbers but maintained integrity remains an unexplained phenomenon that might serve for sound transmission from air to the labyrinth. Here we analysed the frequency, size and composition of osteocyte lacunae in the auditory ossicles of 22 individuals from early postnatal period to old age. Mineralization of the bone matrix was determined using backscattered electron imaging. No signs of bone remodelling were observed above the age of 1 year. We detected characteristics of early bone tissue aging, such as decrease in osteocytes, lower total lacunar density and lacunar area, as well as high matrix mineralization accompanied by distinct accumulation of micropetrotic lacunae and decreased indentation depths. The majority of these changes took place in the first months and years of life, while afterwards only minor reorganization was present. With osteocyte apoptosis potentially being a consequence of low mechanical stimuli, the early loss of osteocytes without initiation of bone remodelling indicates an adaptive response conserving the architecture of the auditory ossicles and ensuring stable sound transmission throughout life.
Collapse
Affiliation(s)
- Tim Rolvien
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Felix N Schmidt
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Petar Milovanovic
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Laboratory for Anthropology, Institute of Anatomy, Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Katharina Jähn
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Christoph Riedel
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Sebastian Butscheidt
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Klaus Püschel
- Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Anke Jeschke
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
8
|
Fatigue as the missing link between bone fragility and fracture. Nat Biomed Eng 2018; 2:62-71. [DOI: 10.1038/s41551-017-0183-9] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 12/07/2017] [Indexed: 02/07/2023]
|
9
|
Abstract
OBJECTIVES Advanced glycation end-products (AGEs) are a post-translational modification of collagen that form spontaneously in the skeletal matrix due to the presence of reducing sugars, such as glucose. The accumulation of AGEs leads to collagen cross-linking, which adversely affects bone quality and has been shown to play a major role in fracture risk. Thus, intervening in the formation and accumulation of AGEs may be a viable means of protecting bone quality. METHODS An in vitro model was used to examine the efficacy of two AGE-inhibitors, aminoguanidine (AG) and pyridoxamine (PM), on ageing human cortical bone. Mid-diaphyseal tibial cortical bone segments were obtained from female cadavers (n = 20, age range: 57 years to 97 years) and randomly subjected to one of four treatments: control; glucose only; glucose and AG; or glucose and PM. Following treatment, each specimen underwent mechanical testing under physiological conditions via reference point indentation, and AGEs were quantified by fluorescence. RESULTS Treatment with AG and PM showed a significant decrease in AGE content versus control groups, as well as a significant decrease in the change in indentation distance, a reliable parameter for analyzing bone strength, via two-way analysis of variance (ANOVA) (p < 0.05). CONCLUSIONS The data suggest that AG and PM prevent AGE formation and subsequent biomechanical degradation in vitro. Modulation of AGEs may help to identify novel therapeutic targets to mitigate bone quality deterioration, especially deterioration due to ageing and in AGE-susceptible populations (e.g. diabetics).Cite this article: Bone Joint Res 2018;7:105-110.
Collapse
Affiliation(s)
- O Abar
- Department of Biology and Department of Orthopaedic Surgery
| | | | - S Y Tang
- Department of Biomedical Engineering and Department of Orthopaedic Surgery, Washington University in St Louis, 1 Brookings Drive, St. Louis, Missouri 63130, USA
| |
Collapse
|
10
|
Karim L, Van Vliet M, Bouxsein ML. Comparison of cyclic and impact-based reference point indentation measurements in human cadaveric tibia. Bone 2018; 106:90-95. [PMID: 25862290 PMCID: PMC7723015 DOI: 10.1016/j.bone.2015.03.021] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 02/20/2015] [Accepted: 03/31/2015] [Indexed: 01/22/2023]
Abstract
Although low bone mineral density (BMD) is strongly associated with increased fracture risk, up to 50% of those who suffer fractures are not detected as high-risk patients by BMD testing. Thus, new approaches may improve identification of those at increased risk for fracture by in vivo assessment of altered bone tissue properties, which may contribute to skeletal fragility. Recently developed reference point indentation (RPI) allows for assessment of cortical bone indentation properties in vivo using devices that apply cyclic loading or impact loading, but there is little information available to assist with interpretation of RPI measurements. Our goals were to use human cadaveric tibia to determine: 1) the associations between RPI variables, cortical bone density, and morphology; 2) the association between variables obtained from RPI systems using cyclic, slow loading versus a single impact load; and 3) age-related differences in RPI variables. We obtained 20 human tibia and femur pairs from female donors (53-97years), measured total hip BMD using dual-energy X-ray absorptiometry, assessed tibial cortical microarchitecture using high-resolution peripheral quantitative computed tomography (HR-pQCT), and assessed cortical bone indentation properties at the mid-tibial diaphysis using both the cyclic and impact-based RPI systems (Biodent and Osteoprobe, respectively, Active Life Scientific, Santa Barbara, CA). We found a few weak associations between RPI variables, BMD, and cortical geometry; a few weak associations between measurements obtained by the two RPI systems; and no age-related differences in RPI variables. Our findings indicate that in cadaveric tibia from older women RPI measurements are largely independent of age, femoral BMD, and cortical geometry. Furthermore, measurements from the cyclic and impact loading RPI devices are weakly related to each other, indicating that each device reflects different aspects of cortical bone indentation properties.
Collapse
Affiliation(s)
- Lamya Karim
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, United States; Department of Orthopedic Surgery, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States; Department of Bioengineering, University of Massachusetts Dartmouth, 285 Old Westport Road, Dartmouth, MA 02747, USA.
| | - Miranda Van Vliet
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, United States.
| | - Mary L Bouxsein
- Center for Advanced Orthopedic Studies, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215, United States; Department of Orthopedic Surgery, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02215, United States.
| |
Collapse
|
11
|
Jenkins T, Katsamenis OL, Andriotis OG, Coutts LV, Carter B, Dunlop DG, Oreffo ROC, Cooper C, Harvey NC, Thurner PJ, The OStEO Group. The inferomedial femoral neck is compromised by age but not disease: Fracture toughness and the multifactorial mechanisms comprising reference point microindentation. J Mech Behav Biomed Mater 2017; 75:399-412. [PMID: 28803114 PMCID: PMC5619645 DOI: 10.1016/j.jmbbm.2017.06.036] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2017] [Revised: 06/26/2017] [Accepted: 06/28/2017] [Indexed: 12/19/2022]
Abstract
The influence of ageing on the fracture mechanics of cortical bone tissue is well documented, though little is known about if and how related material properties are further affected in two of the most prominent musculoskeletal diseases, osteoporosis and osteoarthritis (OA). The femoral neck, in close proximity to the most pertinent osteoporotic fracture site and near the hip joint affected by osteoarthritis, is a site of particular interest for investigation. We have recently shown that Reference Point micro-Indentation (RPI) detects differences between cortical bone from the femoral neck of healthy, osteoporotic fractured and osteoarthritic hip replacement patients. RPI is a new technique with potential for in vivo bone quality assessment. However, interpretation of RPI results is limited because the specific changes in bone properties with pathology are not well understood and, further, because it is not conclusive what properties are being assessed by RPI. Here, we investigate whether the differences previously detected between healthy and diseased cortical bone from the femoral neck might reflect changes in fracture toughness. Together with this, we investigate which additional properties are reflected in RPI measures. RPI (using the Biodent device) and fracture toughness tests were conducted on samples from the inferomedial neck of bone resected from donors with: OA (41 samples from 15 donors), osteoporosis (48 samples from 14 donors) and non age-matched cadaveric controls (37 samples from 10 donoros) with no history of bone disease. Further, a subset of indented samples were imaged using micro-computed tomography (3 osteoporotic and 4 control samples each from different donors) as well as fluorescence microscopy in combination with serial sectioning after basic fuchsin staining (7 osteoporotic and 5 control samples from 5 osteoporotic and 5 control donors). In this study, the bulk indentation and fracture resistance properties of the inferomedial femoral neck in osteoporotic fracture, severe OA and control bone were comparable (p > 0.05 for fracture properties and <10% difference for indentation) but fracture toughness reduced with advancing age (7.0% per decade, r = -0.36, p = 0.029). Further, RPI properties (in particular, the indentation distance increase, IDI) showed partial correlation with fracture toughness (r = -0.40, p = 0.023) or derived elastic modulus (r = -0.40, p = 0.023). Multimodal indent imaging revealed evidence of toughening mechanisms (i.e. crack deflection, bridging and microcracking), elastoplastic response (in terms of the non-conical imprint shape and presence of pile-up) and correlation of RPI with damage extent (up to r = 0.79, p = 0.034) and indent size (up to r = 0.82, p < 0.001). Therefore, crack resistance, deformation resistance and, additionally, micro-structure (porosity: r = 0.93, p = 0.002 as well as pore proximity: r = -0.55, p = 0.027 for correlation with IDI) are all contributory to RPI. Consequently, it becomes clear that RPI measures represent a multitude of properties, various aspects of bone quality, but are not necessarily strongly correlated to a single mechanical property. In addition, osteoporosis or osteoarthritis do not seem to further influence fracture toughness of the inferomedial femoral neck beyond natural ageing. Since bone is highly heterogeneous, whether this finding can be extended to the whole femoral neck or whether it also holds true for other femoral neck quadrants or other material properties remains to be shown.
Collapse
Affiliation(s)
- T Jenkins
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK; Gait Laboratory, Queen Mary's Hospital, St George's University Hospitals NHS Foundation Trust, London, UK
| | - O L Katsamenis
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK; µ-VIS X-ray Imaging Centre, Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK
| | - O G Andriotis
- Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria
| | - L V Coutts
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - B Carter
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - D G Dunlop
- University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - R O C Oreffo
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Institute for Development Sciences, Faculty of Medicine, University of Southampton, Southampton, UK
| | - C Cooper
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK; NIHR Musculoskeletal Biomedical Research Unit, University of Oxford, Oxford, UK; NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - N C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK; NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - P J Thurner
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK; Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria.
| | - The OStEO Group
- University Hospital Southampton NHS Foundation Trust, Southampton, UK; MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK; NIHR Musculoskeletal Biomedical Research Unit, University of Oxford, Oxford, UK; Portsmouth Hospitals NHS Trust, Portsmouth, UK; University College London, London, UK
| |
Collapse
|
12
|
Arnold M, Zhao S, Ma S, Giuliani F, Hansen U, Cobb JP, Abel RL, Boughton O. Microindentation - a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017; 6:542-549. [PMID: 28924020 PMCID: PMC5631024 DOI: 10.1302/2046-3758.69.bjr-2016-0317.r2] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2016] [Accepted: 07/07/2017] [Indexed: 01/26/2023] Open
Abstract
Objectives Microindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness. Methods A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded. Results A total of 1094 abstracts were retrieved and 32 papers were included in the analysis, 20 of which used reference point indentation, and 12 of which used traditional depth-sensing indentation. There are several factors that must be considered when using microindentation, such as tip size, depth and method of analysis. Only two studies validated microindentation against traditional mechanical testing techniques. Both studies used reference point indentation (RPI), with one showing that RPI parameters correlate well with mechanical testing, but the other suggested that they do not. Conclusion Microindentation has been used in various studies to assess bone stiffness, but only two studies with conflicting results compared microindentation with traditional mechanical testing techniques. Further research, including more studies comparing microindentation with other mechanical testing methods, is needed before microindentation can be used reliably to calculate cortical bone stiffness. Cite this article: M. Arnold, S. Zhao, S. Ma, F. Giuliani, U. Hansen, J. P. Cobb, R. L. Abel, O. Boughton. Microindentation – a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017;6:542–549. DOI: 10.1302/2046-3758.69.BJR-2016-0317.R2.
Collapse
Affiliation(s)
- M Arnold
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK
| | - S Zhao
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK
| | - S Ma
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK and Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | - F Giuliani
- Imperial College London, Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | - U Hansen
- Imperial College London, Department of Mechanical Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | - J P Cobb
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK
| | - R L Abel
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK
| | - O Boughton
- Imperial College London, The MSk Lab, Imperial College London, Charing Cross Hospital, London W6 8RF, UK
| |
Collapse
|
13
|
Malgo F, Hamdy NAT, Papapoulos SE, Appelman-Dijkstra NM. Bone material strength index as measured by impact microindentation is low in patients with fractures irrespective of fracture site. Osteoporos Int 2017; 28:2433-2437. [PMID: 28466137 PMCID: PMC5524858 DOI: 10.1007/s00198-017-4054-8] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Accepted: 04/12/2017] [Indexed: 02/07/2023]
Abstract
UNLABELLED We evaluated the relationship between bone material strength index (BMSi) and fragility fractures, including vertebral fractures. Our data showed that BMSi is low in all fracture patients with low bone mass, independently of whether patients sustained a vertebral or a non-vertebral fracture. INTRODUCTION Impact microindentation (IMI) is a new technique for the measurement of tissue level properties of cortical bone in vivo. Previous studies showed an association between BMSi and non-vertebral fractures, but an association with vertebral fractures is still being debated. The objective of this paper was to evaluate the relationship between BMSi and different types of fragility fractures, including vertebral fractures. METHODS In this cross-sectional study, we measured BMSi in patients of both sexes with different types of fragility fractures and low bone mass with the IMI method using the Osteoprobe®. Vertebral fractures were diagnosed and graded on lateral spine radiographs. RESULTS A total of 132 patients were included in the study, of whom 101 patients (65 women) had sustained a low energy fracture and 31 (mean age 57.7 ± 9.9 years) had no history or radiological evidence for a fracture. Of the fracture patients, 53 (mean age 62.8 ± 8.3 years) had only non-vertebral fractures (VF-/Fx+), 34 (mean age 62.8 ± 9.9 years) had vertebral and non-vertebral fractures (VF+/Fx+), and 14 (mean age 64.7 ± 9.3 years) had only vertebral fractures (VF+/Fx-). BMSi values, adjusted for age and BMD, were similar for all three groups of fracture patients (78.9 ± 0.7, 78.3 ± 0.9, and 78.4 ± 1.4, respectively; p = 0.866). BMSi values were not associated with number or severity of vertebral fractures. CONCLUSION Our data demonstrate that BMSi is low in fracture patients with low bone mass, irrespective of whether they sustained a vertebral fracture or a non-vertebral fracture.
Collapse
Affiliation(s)
- F Malgo
- Center for Bone Quality and Department of Medicine, Division Endocrinology, Leiden University Medical Center, P.O. Box 9600, 2300, RC, Leiden, The Netherlands
| | - N A T Hamdy
- Center for Bone Quality and Department of Medicine, Division Endocrinology, Leiden University Medical Center, P.O. Box 9600, 2300, RC, Leiden, The Netherlands
| | - S E Papapoulos
- Center for Bone Quality and Department of Medicine, Division Endocrinology, Leiden University Medical Center, P.O. Box 9600, 2300, RC, Leiden, The Netherlands
| | - N M Appelman-Dijkstra
- Center for Bone Quality and Department of Medicine, Division Endocrinology, Leiden University Medical Center, P.O. Box 9600, 2300, RC, Leiden, The Netherlands.
| |
Collapse
|
14
|
Uppuganti S, Granke M, Manhard MK, Does MD, Perrien DS, Lee DH, Nyman JS. Differences in sensitivity to microstructure between cyclic- and impact-based microindentation of human cortical bone. J Orthop Res 2017; 35:1442-1452. [PMID: 27513922 PMCID: PMC5530367 DOI: 10.1002/jor.23392] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 08/09/2016] [Indexed: 02/04/2023]
Abstract
Unlike the known relationships between traditional mechanical properties and microstructural features of bone, the factors that influence the mechanical resistance of bone to cyclic reference point microindention (cRPI) and impact microindention (IMI) have yet to be identified. To determine whether cRPI and IMI properties depend on microstructure, we indented the tibia mid-shaft, the distal radius, and the proximal humerus from 10 elderly donors using the BioDent and OsteoProbe (neighboring sites). As the only output measure of IMI, bone material strength index (BMSi) was significantly different across all three anatomical sites being highest for the tibia mid-shaft and lowest for the proximal humerus. Total indentation distance (inverse of BMSi) was higher for the proximal humerus than for the tibia mid-shaft but was not different between other anatomical comparisons. As a possible explanation for the differences in BMSi, pore water, as determined by 1 H nuclear magnetic resonance, was lowest for the tibia and highest for the humerus. Moreover, the local intra-cortical porosity, as determined by micro-computed tomography, was negatively correlated with BMSi for both arm bones. BMSi was also positively correlated with peak bending stress of cortical bone extracted from the tibia mid-shaft. Microstructural correlations with cRPI properties were not significant for any of the bones. The one exception was that average energy dissipated during cRPI was negatively correlated with local tissue mineral density in the tibia mid-shaft. With higher indentation force and larger tip diameter than cRPI, only IMI appears to be sensitive to the underlying porosity of cortical bone. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1442-1452, 2017.
Collapse
Affiliation(s)
- Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Mathilde Granke
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Mary Kate Manhard
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232
| | - Mark D. Does
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232,Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Daniel S. Perrien
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232,Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232,Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
| | - Donald H. Lee
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232
| | - Jeffry S. Nyman
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232,Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232,Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232,Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212
| |
Collapse
|
15
|
Sosa DD, Eriksen EF. Reduced Bone Material Strength is Associated with Increased Risk and Severity of Osteoporotic Fractures. An Impact Microindentation Study. Calcif Tissue Int 2017; 101:34-42. [PMID: 28246929 DOI: 10.1007/s00223-017-0256-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Accepted: 02/10/2017] [Indexed: 01/22/2023]
Abstract
The aim of the study was to test, whether bone material strength differs between different subtypes of osteoporotic fracture and assess whether it relates to vertebral fracture severity. Cortical bone material strength index (BMSi) was measured by impact microindentation in 66 women with osteoporotic fracture and 66 age- and sex-matched controls without fracture. Bone mineral density (BMD) and bone turnover markers were also assessed. Vertebral fracture severity was graded by semiquantitative (SQ) grading. Receiver operator characteristic (ROC) curves were used to examine the ability of BMSi to discriminate fractures. Subjects with osteoporotic fractures exhibited lower BMSi than controls (71.5 ± 7.3 vs. 76.4 ± 6.2, p < 0.001). After adjusting for age and hip BMD, a significant negative correlation was seen between BMSi and vertebral fracture severity (r 2 = 0.19, p = 0.007). A decrease of one standard deviation (SD) in BMSi was associated with increased risk of fracture (OR 2.62; 95% CI 1.35, 5.10, p = 0.004). ROC curve areas under the curve (AUC) for BMSi in subjects with vertebral fracture (VF), hip fracture (HF), and non-vertebral non-hip fracture (NVNHFx), (mean; 95% CI) were 0.711 (0.608; 0.813), 0.712 (0.576; 0.843), 0.689 (0.576; 0.775), respectively. Combining BMSi and BMD provided further improvement in the discrimination of fractures with AUC values of 0.777 (0.695; 0.858), 0.789 (0.697; 0.882), and 0.821 (0.727; 0.914) for VFx, HFx, and NVNHFx, respectively. Low BMSi of the tibial cortex is associated with increased risk of all osteoporotic fractures and severity of vertebral fractures.
Collapse
Affiliation(s)
- Daysi Duarte Sosa
- Department of Clinical Endocrinology, Morbid Obesity and Preventive Medicine, Oslo University Hospital, Institute of Clinical Medicine, Oslo University, Pb 4956 Nydalen, NO-0424, Oslo, Norway.
| | - Erik Fink Eriksen
- Department of Clinical Endocrinology, Morbid Obesity and Preventive Medicine, Oslo University Hospital, Institute of Clinical Medicine, Oslo University, Pb 4956 Nydalen, NO-0424, Oslo, Norway
| |
Collapse
|
16
|
Coutts LV, Jenkins T, Oreffo ROC, Dunlop DG, Cooper C, Harvey NC, Thurner PJ. Local Variation in Femoral Neck Cortical Bone: In Vitro Measured Bone Mineral Density, Geometry and Mechanical Properties. J Clin Densitom 2017; 20:205-215. [PMID: 26710681 DOI: 10.1016/j.jocd.2015.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2015] [Revised: 10/12/2015] [Accepted: 10/21/2015] [Indexed: 01/08/2023]
Abstract
Age- and disease (osteoporotic fractured and osteoarthritic tissue)-related changes in the distribution of cortical bone were examined, using a multimodality approach, including measurement of local density, geometry and mechanical properties, where changes in these properties can give rise to instability and increasing probability of fracture. In contrast to the majority of previously reported research, this study also focuses on the characteristic non-circular femoral neck cross-sectional geometry and variation in bone mineral density (BMD) around the femoral neck. Twenty-two osteoarthritic and 7 osteoporotic femoral neck slices, collected from elective and trauma-related arthroplasty, and 16 cadaveric donor tissue controls were tested mechanically using Reference Point Indentation (BioDent™, Active Life Technologies®, Santa Barbara, CA) and then scanned with in vitro-based radiography intended to replicate the dual-energy X-ray absorptiometry technique. All parameters were measured regionally around the circumference of the femoral neck, allowing examination of spatial variability within the cortical bone. Fractured tissue was less resistant to indentation in the thinner superolateral segment compared to other segments and other groups. BMD around the fractured femoral necks appeared more consistent than that of nonfractured tissue, where BMD was reduced in the superolateral segment for the other groups. Cortical bone was thin in the superolateral segment for all groups except for the osteoarthritic group, and was thicker in the inferomedial segment for both osteoarthritic and fractured groups, resulting in the largest variation in buckling ratio (ratio of cortical bone diameter to cortical bone thickness) around the femoral neck for the fractured group. With age, healthy controls appeared to have lower inferomedial cortical thickness, whereas no significant differences in Reference Point Indentation measurements and density were observed. The study has highlighted several (both quality- and quantity-related) parameters that may be used to improve prediction of fracture risk.
Collapse
Affiliation(s)
- Louise V Coutts
- Faculty of Engineering and Environment and Faculty of Medicine, University of Southampton, Southampton, UK.
| | - Thomas Jenkins
- Faculty of Engineering and Environment and Faculty of Medicine, University of Southampton, Southampton, UK
| | - Richard O C Oreffo
- Faculty of Engineering and Environment and Faculty of Medicine, University of Southampton, Southampton, UK
| | - Doug G Dunlop
- Southampton University Hospitals NHS Trust, Southampton, UK
| | - Cyrus Cooper
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
| | - Philipp J Thurner
- Faculty of Engineering and Environment and Faculty of Medicine, University of Southampton, Southampton, UK; Institute of Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria
| |
Collapse
|
17
|
Kennedy OD, Lendhey M, Mauer P, Philip A, Basta-Pljakic J, Schaffler MB. Microdamage induced by in vivo Reference Point Indentation in mice is repaired by osteocyte-apoptosis mediated remodeling. Bone 2017; 95:192-198. [PMID: 27919734 PMCID: PMC5776007 DOI: 10.1016/j.bone.2016.11.029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 11/11/2016] [Accepted: 11/30/2016] [Indexed: 11/24/2022]
Abstract
Reference Point Indentation (RPI) is a technology that is designed to measure mechanical properties that relate to bone toughness, or its ability to resist crack growth, in vivo. Independent of the mechanical parameters generated by RPI, its ability to initiate and propagate microcracks in bone is itself an interesting issue. Microcracks have a crucial biological relevance in bone, are central to its ability to maintain homeostasis. In healthy tissues, a process of targeted remodeling routinely repairs microcracks in a process mediated by osteocyte apoptosis. However, in diseases such as osteoporosis this process becomes deficient and microcracks can accumulate. Small animal models such are crucial for the study of such diseases, but it is technically challenging to create microcracks in these animals without causing outright failure. Therefore we sought to use RPI as a focal microdamage placement tool, to introduce microcracks to mouse long bones and investigate whether the same pathway mediates their repair as that described in other microdamage systems. We first used SEM to confirm that microdamage is formed RPI in mouse bone. Then, since RPI is carried out transdermally, we sought to confirm that no periosteal response occurred at the indented region. We then used a pan-caspase inhibitor (QVD) to determine whether osteocyte apoptosis plays the same pivotal role in microdamage repair in this model, as has been demonstrated in others. In conclusion, we validated that the microdamage-apoptosis-remodeling pathway is maintained with this method of microdamage induction in mice. We show that RPI can be used as a reliable and reproducible microdamage placement tool in living mouse long bones without inducing a periosteal response. We also used a caspase inhibitor, to block osteocyte apoptosis and thus abrogate the remodeling response to microdamage. This demonstrates that the well described microdamage repair system, involving targeted remodeling mediated by osteocyte apoptosis, is conserved in this novel mouse model using an in vivo RPI loading system.
Collapse
Affiliation(s)
- Oran D Kennedy
- New York University School of Medicine NY, United States.
| | - Matin Lendhey
- New York University School of Medicine NY, United States
| | - Peter Mauer
- The City College of New York, NY; The Royal College of Surgeons in Ireland, Ireland
| | | | | | | |
Collapse
|
18
|
Abstract
Background and purpose - Bone fragility is determined by bone mass, bone architecture, and the material properties of bone. Microindentation has been introduced as a measurement method that reflects bone material properties. The pathogenesis of underlying stress fractures, in particular the role of impaired bone material properties, is still poorly understood. Based on the hypothesis that impaired bone material strength might play a role in the development of stress fractures, we used microindentation in patients with stress fractures and in controls. Patients and methods - We measured bone material strength index (BMSi) by microindentation in 30 women with previous stress fractures and in 30 normal controls. Bone mineral density by DXA and levels of the bone markers C-terminal cross-linking telopeptide of type-1 collagen (CTX) and N-terminal propeptide of type-1 procollagen (P1NP) were also determined. Results - Mean BMSi in stress fracture patients was significantly lower than in the controls (SD 72 (8.7) vs. 77 (7.2); p = 0.02). The fracture subjects also had a significantly lower mean bone mineral density (BMD) than the controls (0.9 (0.02) vs. 1.0 (0.06); p = 0.03). Bone turnover-as reflected in serum levels of the bone marker CTX-was similar in both groups, while P1NP levels were significantly higher in the women with stress fractures (55 μg/L vs. 42 μg/L; p = 0.03). There was no correlation between BMSi and BMD or bone turnover. Interpretation - BMSi was inferior in patients with previous stress fracture, but was unrelated to BMD and bone turnover. The lower values of BMSi in patients with previous stress fracture combined with a lower BMD may contribute to the increased propensity to develop stress fractures in these patients.
Collapse
|
19
|
Idkaidek A, Agarwal V, Jasiuk I. Finite element simulation of Reference Point Indentation on bone. J Mech Behav Biomed Mater 2016; 65:574-583. [PMID: 27721174 DOI: 10.1016/j.jmbbm.2016.08.031] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2015] [Revised: 07/13/2016] [Accepted: 08/19/2016] [Indexed: 12/30/2022]
Abstract
Reference Point Indentation (RPI) is a novel technique aimed to assess bone quality. Measurements are recorded by the BioDent instrument that applies multiple indents to the same location of cortical bone. Ten RPI parameters are obtained from the resulting force-displacement curves. Using the commercial finite element analysis software Abaqus, we assess the significance of the RPI parameters. We create an axisymmetric model and employ an isotropic viscoelastic-plastic constitutive relation with damage to simulate indentations on a human cortical bone. Fracture of bone tissue is not simulated for simplicity. The RPI outputs are computed for different simulated test cases and then compared with experimental results, measured using the BioDent, found in literature. The number of cycles, maximum indentation load, indenter tip radius, and the mechanical properties of bone: Young׳s modulus, compressive yield stress, and viscosity and damage constants, are varied. The trends in the RPI parameters are then investigated. We find that the RPI parameters are sensitive to the mechanical properties of bone. An increase in Young׳s modulus of bone causes the force-displacement loading and unloading slopes to increase and the total indentation distance (TID) to decrease. The compressive yield stress is inversely proportional to a creep indentation distance (CID1) and the TID. The viscosity constant is proportional to the CID1 and an average of the energy dissipated (AvED). The maximum indentation load is proportional to the TID, CID1, loading and unloading slopes, and AvED. The damage parameter is proportional to the TID, but it is inversely proportional to both the loading and unloading slopes and the AvED. The value of an indenter tip radius is proportional to the CID1 and inversely proportional to the TID. The number of load cycles is inversely proportional to an average of a creep indentation depth (AvCID) and the AvED. The indentation distance increase (IDI) is strongly inversely proportional to the compressive yield stress, and strongly proportional to the viscosity constant and maximum applied load, but has weak relation with the damage parameter, indenter tip radius, and elastic modulus. This computational study advances our understanding of the RPI outputs and provides a starting point for more comprehensive computational studies of the RPI technique.
Collapse
Affiliation(s)
- Ashraf Idkaidek
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 West Green Street, Urbana, IL 61801, United States
| | - Vineet Agarwal
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 West Green Street, Urbana, IL 61801, United States
| | - Iwona Jasiuk
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 West Green Street, Urbana, IL 61801, United States.
| |
Collapse
|
20
|
Lescun TB, Hoffseth K, Yang HT, Hansma PK, Kopeikin HS, Chandrasekar S. Effect of various testing conditions on results for a handheld reference point indentation instrument in horses. Am J Vet Res 2016; 77:39-49. [PMID: 26709935 DOI: 10.2460/ajvr.77.1.39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare results obtained with a handheld reference point indentation instrument for bone material strength index (BMSi) measurements in the equine third metacarpal bone for various testing conditions. SAMPLE 24 third metacarpal bones. PROCEDURES Third metacarpal bones from both forelimbs of 12 horses were obtained. The dorsal surface of each bone was divided into 6 testing regions. In vivo and ex vivo measurements of BMSi were obtained through the skin and on exposed bone, respectively, to determine effects of each testing condition. Difference plots were used to assess agreement between BMSi obtained for various conditions. Linear regression analysis was used to assess effects of age, sex, and body weight on BMSi. A mixed-model ANOVA was used to assess effects of age, sex, limb, bone region, and testing condition on BMSi values. RESULTS Indentation measurements were performed on standing sedated and recumbent anesthetized horses and on cadaveric bone. Regional differences in BMSi values were detected in adult horses. A significant linear relationship (r(2) = 0.71) was found between body weight and BMSi values. There was no difference between in vivo and ex vivo BMSi values. A small constant bias was detected between BMSi obtained through the skin, compared with values obtained directly on bone. CONCLUSIONS AND CLINICAL RELEVANCE Reference point indentation can be used for in vivo assessment of the resistance of bone tissue to microfracture in horses. Testing through the skin should account for a small constant bias, compared with results for testing directly on exposed bone.
Collapse
|
21
|
Bone quality assessment techniques: geometric, compositional, and mechanical characterization from macroscale to nanoscale. Clin Rev Bone Miner Metab 2016; 14:133-149. [PMID: 28936129 DOI: 10.1007/s12018-016-9222-4] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
This review presents an overview of the characterization techniques available to experimentally evaluate bone quality, defined as the geometric and material factors that contribute to fracture resistance independently of areal bone mineral density (aBMD) assessed by dual energy x-ray absorptiometry. The methods available for characterization of the geometric, compositional, and mechanical properties of bone across multiple length scales are summarized, along with their outcomes and their advantages and disadvantages. Examples of how each technique is used are discussed, as well as practical concerns such as sample preparation and whether or not each testing method is destructive. Techniques that can be used in vivo and those that have been recently improved or developed are emphasized, including high resolution peripheral quantitative computed tomography to evaluate geometric properties and reference point indentation to evaluate material properties. Because no single method can completely characterize bone quality, we provide a framework for how multiple characterization methods can be used together to generate a more comprehensive analysis of bone quality to complement aBMD in fracture risk assessment.
Collapse
|
22
|
McNerny EMB, Organ JM, Wallace JM, Newman CL, Brown DM, Allen MR. Assessing the inter- and intra-animal variability of in vivo OsteoProbe skeletal measures in untreated dogs. Bone Rep 2016; 5:192-198. [PMID: 27588301 PMCID: PMC5003524 DOI: 10.1016/j.bonr.2016.08.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
The OsteoProbe is a second-generation reference point indentation (RPI) device without a reference probe that is designed to simplify RPI testing for clinical use. Successful clinical implementation of the OsteoProbe would benefit from a better understanding of how its output, bone material strength index (BMSi), relates to the material properties of bone and under what conditions it reliably correlates with fracture risk. Large animal models have the potential to help fill this knowledge gap, as cadaveric studies are retrospective and limited by incomplete patient histories (including the potential use of bone matrix altering drugs such as bisphosphonates). The goal of this study was to assess the intra and inter-animal variability of OsteoProbe measures in untreated beagle dogs (n = 12), and to evaluate this variability in comparison to traditional mechanical testing. OsteoProbe measurements were performed in vivo on the left tibia of each dog and repeated 6 months later on the day of sacrifice. Within-animal variation of BMSi (CV of 5–10 indents) averaged 8.9 and 9.0% at the first and second timepoints, respectively. In contrast, inter-animal variation of BMSi increased from 5.3% to 9.1%. The group variation of BMSi was on par with that of traditional 3-point mechanical testing; inter-animal variation was 10% for ultimate force, 13% for stiffness, and 12% for total work as measured on the femur. There was no significant change in mean BMSi after 6 months, but the individual change with time across the 12 dogs was highly variable, ranging from − 12.4% to + 21.7% (mean 1.6%, SD 10.6%). No significant correlations were found between in vivo tibia BMSi and femur mechanical properties measured by ex vivo 3-pt bending, but this may be a limitation of sample size or the tests being performed on different bones. No relationship was found between BMSi and tissue mineral density, but a strong positive correlation was found between BMSi and tibia cortical thickness (ρ = 0.706, p = 0.010). This report shows that while the OsteoProbe device has inter-individual variability quite similar to that of traditional mechanical testing, the longitudinal changes show high levels of heterogeneity across subjects. We further highlight the need for standardization in post-testing data processing and further study of the relationships between OsteoProbe and traditional mechanical testing. OsteoProbe bone material strength index (BMSi) was assessed in female beagle dogs. The inter-subject variance of BMSi was comparable to traditional mechanical tests. Longitudinal changes in BMSi over 6 months were heterogeneous across subjects. Femur mechanical properties measured by bending did not correlate with tibia BMSi. The need for standardization of OsteoProbe post-test data processing is discussed.
Collapse
Affiliation(s)
- Erin M B McNerny
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Jason M Organ
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University Purdue University of Indianapolis, Indianapolis, IN, United States
| | - Christopher L Newman
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Drew M Brown
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Matthew R Allen
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States; Department of Biomedical Engineering, Indiana University Purdue University of Indianapolis, Indianapolis, IN, United States
| |
Collapse
|
23
|
Abstract
Tissue-level mechanical properties characterize mechanical behavior independently of microscopic porosity. Specifically, quasi-static nanoindentation provides measurements of modulus (stiffness) and hardness (resistance to yielding) of tissue at the length scale of the lamella, while dynamic nanoindentation assesses time-dependent behavior in the form of storage modulus (stiffness), loss modulus (dampening), and loss factor (ratio of the two). While these properties are useful in establishing how a gene, signaling pathway, or disease of interest affects bone tissue, they generally do not vary with aging after skeletal maturation or with osteoporosis. Heterogeneity in tissue-level mechanical properties or in compositional properties may contribute to fracture risk, but a consensus on whether the contribution is negative or positive has not emerged. In vivo indentation of bone tissue is now possible, and the mechanical resistance to microindentation has the potential for improving fracture risk assessment, though determinants are currently unknown.
Collapse
Affiliation(s)
- Jeffry S Nyman
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. S., South Tower, Suite 4200, Nashville, TN, 37232, USA.
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37212, USA.
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA.
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37232, USA.
| | - Mathilde Granke
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, 1215 21st Ave. S., South Tower, Suite 4200, Nashville, TN, 37232, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, 37212, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| | - Robert C Singleton
- Materials Science and Engineering Department, University of Tennessee, Knoxville, TN, 37996, USA
| | - George M Pharr
- Materials Science and Engineering Department, University of Tennessee, Knoxville, TN, 37996, USA
- Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN, 37831, USA
| |
Collapse
|
24
|
Abraham AC, Agarwalla A, Yadavalli A, Liu JY, Tang SY. Microstructural and compositional contributions towards the mechanical behavior of aging human bone measured by cyclic and impact reference point indentation. Bone 2016; 87:37-43. [PMID: 27021150 PMCID: PMC4862905 DOI: 10.1016/j.bone.2016.03.013] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 03/23/2016] [Accepted: 03/24/2016] [Indexed: 02/05/2023]
Abstract
The assessment of fracture risk often relies primarily on measuring bone mineral density, thereby accounting for only a single pathology: the loss of bone mass. However, bone's ability to resist fracture is a result of its biphasic composition and hierarchical structure that imbue it with high strength and toughness. Reference point indentation (RPI) testing is designed to directly probe bone mechanical behavior at the microscale in situ, although it remains unclear which aspects of bone composition and structure influence the results at this scale. Therefore, our goal in this study was to investigate factors that contribute to bone mechanical behavior measured by cyclic reference point indentation, impact reference point indentation, and three-point bending. Twenty-eight female cadavers (ages 57-97) were subjected to cyclic and impact RPI in parallel at the unmodified tibia mid-diaphysis. After RPI, the middiaphyseal tibiae were removed, scanned using micro-CT to obtain cortical porosity (Ct.Po.) and tissue mineral density (TMD), then tested using three-point bending, and lastly assayed for the accumulation of advanced glycation end-products (AGEs). Both the indentation distance increase from cyclic RPI (IDI) and bone material strength index from impact RPI (BMSi) were significantly correlated with TMD (r=-0.390, p=0.006; r=0.430, p=0.002; respectively). Accumulation of AGEs was significantly correlated with IDI (r=0.281, p=0.046), creep indentation distance (CID, r=0.396, p=0.004), and BMSi (r=-0.613, p<0.001). There were no significant relationships between tissue TMD or AGEs accumulation with the quasi-static material properties. Toughness decreased with increasing tissue Ct.Po. (r=-0.621, p<0.001). Other three-point bending measures also correlated with tissue Ct.Po. including the bending modulus (r=-0.50, p<0.001) and ultimate stress (r=-0.56, p<0.001). The effects of Ct.Po. on indentation were less pronounced with IDI (r=0.290, p=0.043) and BMSi (r=-0.299, p=0.037) correlated modestly with tissue Ct.Po. These results suggest that RPI may be sensitive to bone quality changes relating to collagen.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA
| | - Avinesh Agarwalla
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA
| | - Aditya Yadavalli
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA
| | - Jenny Y Liu
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA
| | - Simon Y Tang
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA; Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA.
| |
Collapse
|
25
|
Furst JR, Bandeira LC, Fan WW, Agarwal S, Nishiyama KK, McMahon DJ, Dworakowski E, Jiang H, Silverberg SJ, Rubin MR. Advanced Glycation Endproducts and Bone Material Strength in Type 2 Diabetes. J Clin Endocrinol Metab 2016; 101:2502-10. [PMID: 27115060 PMCID: PMC4891790 DOI: 10.1210/jc.2016-1437] [Citation(s) in RCA: 137] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
CONTEXT Skeletal deterioration, leading to an increased risk of fracture, is a known complication of type 2 diabetes mellitus (T2D). Yet plausible mechanisms to account for skeletal fragility in T2D have not been clearly established. OBJECTIVE The objective of the study was to determine whether bone material properties, as measured by reference point indentation, and advanced glycation endproducts (AGEs), as determined by skin autofluorescence (SAF), are related in patients with T2D. DESIGN This was a cross-sectional study. SETTING The study was conducted at a tertiary medical center. PATIENTS Sixteen postmenopausal women with T2D and 19 matched controls participated in the study. MAIN OUTCOME MEASURES Bone material strength index (BMSi) by in vivo reference point indentation, AGE accumulation by SAF, and circulating bone turnover markers were measured. RESULTS BMSi was reduced by 9.2% in T2D (P = .02) and was inversely associated with the duration of T2D (r = -0.68, P = .004). Increased SAF was associated with reduced BMSi (r = -0.65, P = .006) and lower bone formation marker procollagen type 1 amino-terminal propeptide (r = -0.63, P = .01) in T2D, whereas no associations were seen in controls. SAF accounted for 26% of the age-adjusted variance in BMSi in T2D (P = .03). CONCLUSIONS Bone material properties are impaired in postmenopausal women with T2D as determined by reference point indentation. The results suggest a role for the accumulation of AGEs to account for inferior BMSi in T2D.
Collapse
Affiliation(s)
- Jessica R Furst
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Leonardo C Bandeira
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Wen-Wei Fan
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Sanchita Agarwal
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Kyle K Nishiyama
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Donald J McMahon
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Elzbieta Dworakowski
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Hongfeng Jiang
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Shonni J Silverberg
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| | - Mishaela R Rubin
- Department of Medicine, Metabolic Bone Diseases Unit, Division of Endocrinology, College of Physicians and Surgeons, Columbia University, New York, New York 10032
| |
Collapse
|
26
|
Krege JB, Aref MW, McNerny E, Wallace JM, Organ JM, Allen MR. Reference point indentation is insufficient for detecting alterations in traditional mechanical properties of bone under common experimental conditions. Bone 2016; 87:97-101. [PMID: 27072518 PMCID: PMC4862890 DOI: 10.1016/j.bone.2016.04.002] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2016] [Revised: 03/21/2016] [Accepted: 04/04/2016] [Indexed: 12/28/2022]
Abstract
Reference point indentation (RPI) was developed as a novel method to assess mechanical properties of bone in vivo, yet it remains unclear what aspects of bone dictate changes/differences in RPI-based parameters. The main RPI parameter, indentation distance increase (IDI), has been proposed to be inversely related to the ability of bone to form/tolerate damage. The goal of this work was to explore the relationshipre-intervention RPI measurebetween RPI parameters and traditional mechanical properties under varying experimental conditions (drying and ashing bones to increase brittleness, demineralizing bones and soaking in raloxifene to decrease brittleness). Beams were machined from cadaveric bone, pre-tested with RPI, subjected to experimental manipulation, post-tested with RPI, and then subjected to four-point bending to failure. Drying and ashing significantly reduced RPI's IDI, as well as ultimate load (UL), and energy absorption measured from bending tests. Demineralization increased IDI with minimal change to bending properties. Ex vivo soaking in raloxifene had no effect on IDI but tended to enhance post-yield behavior at the structural level. These data challenge the paradigm of an inverse relationship between IDI and bone toughness, both through correlation analyses and in the individual experiments where divergent patterns of altered IDI and mechanical properties were noted. Based on these results, we conclude that RPI measurements alone, as compared to bending tests, are insufficient to reach conclusions regarding mechanical properties of bone. This proves problematic for the potential clinical use of RPI measurements in determining fracture risk for a single patient, as it is not currently clear that there is an IDI, or even a trend of IDI, that can determine clinically relevant changes in tissue properties that may contribute to whole bone fracture resistance.
Collapse
Affiliation(s)
- John B Krege
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Mohammad W Aref
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Erin McNerny
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University Purdue University of Indianapolis, Indianapolis, IN, United States
| | - Jason M Organ
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States
| | - Matthew R Allen
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, United States; Department of Biomedical Engineering, Indiana University Purdue University of Indianapolis, Indianapolis, IN, United States.
| |
Collapse
|
27
|
Huang TH, Ables GP. Dietary restrictions, bone density, and bone quality. Ann N Y Acad Sci 2016; 1363:26-39. [PMID: 26881697 DOI: 10.1111/nyas.13004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 12/08/2015] [Accepted: 12/16/2015] [Indexed: 02/06/2023]
Abstract
Caloric restriction (CR), protein restriction (PR), and specific amino acid restriction (e.g., methionine restriction (MR)) are different dietary interventions that have been confirmed with regard to their comprehensive benefits to metabolism and health. Based on bone densitometric measurements, weight loss induced by dietary restriction is known to be accompanied by reduced areal bone mineral density, bone mass, and/or bone size, and it is considered harmful to bone health. However, because of technological advancements in bone densitometric instruments (e.g., high-resolution X-ray tomography), dietary restrictions have been found to cause a reduction in bone mass/size rather than volumetric bone mineral density. Furthermore, when considering bone quality, bone health consists of diverse indices that cannot be fully represented by densitometric measurements alone. Indeed, there is evidence that moderate dietary restrictions do not impair intrinsic bone material properties, despite the reduction in whole-bone strength because of a smaller bone size. In the present review, we integrate research evidence from traditional densitometric measurements, metabolic status assays (e.g., energy metabolism, oxidative stresses, and inflammatory responses), and biomaterial analyses to provide revised conclusions regarding the effects of CR, PR, and MR on the skeleton.
Collapse
Affiliation(s)
- Tsang-hai Huang
- Laboratory of Exercise, Nutrition and Bone Biology, Institute of Physical Education, Health and Leisure Studies, National Cheng Kung University, Tainan, Taiwan
| | - Gene P Ables
- Orentreich Foundation for the Advancement of Science, Cold Spring-on-Hudson, New York
| |
Collapse
|
28
|
Ouattara A, Cooke D, Gopalakrishnan R, Huang TH, Ables GP. Methionine restriction alters bone morphology and affects osteoblast differentiation. Bone Rep 2016; 5:33-42. [PMID: 28326345 PMCID: PMC4926829 DOI: 10.1016/j.bonr.2016.02.002] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 01/20/2016] [Accepted: 02/08/2016] [Indexed: 12/22/2022] Open
Abstract
Methionine restriction (MR) extends the lifespan of a wide variety of species, including rodents, drosophila, nematodes, and yeasts. MR has also been demonstrated to affect the overall growth of mice and rats. The objective of this study was to evaluate the effect of MR on bone structure in young and aged male and female C57BL/6J mice. This study indicated that MR affected the growth rates of males and young females, but not aged females. MR reduced volumetric bone mass density (vBMD) and bone mineral content (BMC), while bone microarchitecture parameters were decreased in males and young females, but not in aged females compared to control-fed (CF) mice. However, when adjusted for bodyweight, the effect of MR in reducing vBMD, BMC and microarchitecture measurements was either attenuated or reversed suggesting that the smaller bones in MR mice is appropriate for its body size. In addition, CF and MR mice had similar intrinsic strength properties as measured by nanoindentation. Plasma biomarkers suggested that the low bone mass in MR mice could be due to increased collagen degradation, which may be influenced by leptin, IGF-1, adiponectin and FGF21 hormone levels. Mouse preosteoblast cell line cultured under low sulfur amino acid growth media attenuated gene expression levels of Col1al, Runx2, Bglap, Alpl and Spp1 suggesting delayed collagen formation and bone differentiation. Collectively, our studies revealed that MR altered bone morphology which could be mediated by delays in osteoblast differentiation. MR affected the growth rates of males and young females, but not aged females. CF and MR mice had similar intrinsic strength properties. Low methionine media attenuated bone differentiation genes in MC3T3-E1 preosteoblast cells. The lower bone mass in MR mice is appropriate for its smaller body size.
Collapse
Key Words
- Aged mice
- BMC, bone mineral content
- BS, bone surface
- BV, bone volume
- CF, control-fed
- CTX-1, C-terminal telopeptide of type 1 collagen
- Conn.Dn., connectivity density
- FGF21, fibroblast growth factor-21
- HFD, high-fat diet
- HHCy, hyperhomocysteinemia
- IDI, indentation depth increase
- IGF-1, insulin-like growth factor-1
- Imax, maximal MOI
- Imin, minimal MOI
- LPD, low protein diet
- MC3T3-E1 subclone 4
- MOI, moment of inertia
- MR, methionine restriction
- Methionine restriction
- Micro-computed tomography
- Nanoindentation
- OC, osteocalcin
- OPG, osteoprotegerin
- P1NP, N-terminal propeptide of type 1 procollagen
- RANKL, receptor activator for nuclear factor κB ligand
- SMI, structure model index
- TV, total volume
- Tb.N, trabecular number
- Tb.Sp, trabecular separation
- Tb.Th, trabecular thickness
- pMOI, polar MOI
- vBMD, volumetric bone mass density
- μCT, micro-computed tomography
Collapse
Affiliation(s)
- Amadou Ouattara
- Orentreich Foundation for the Advancement of Science, Inc, 855 Route 301, Cold Spring, NY 10516, USA
| | - Diana Cooke
- Orentreich Foundation for the Advancement of Science, Inc, 855 Route 301, Cold Spring, NY 10516, USA
| | - Raj Gopalakrishnan
- School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA
| | - Tsang-hai Huang
- Institute of Physical Education, Health and Leisure Studies, National Cheng Kung University, Tainan City, Taiwan
| | - Gene P. Ables
- Orentreich Foundation for the Advancement of Science, Inc, 855 Route 301, Cold Spring, NY 10516, USA
- Corresponding author at: Orentreich Foundation for the Advancement of Science, Inc., 855 Route 301, Cold Spring, NY 10516, USA.Orentreich Foundation for the Advancement of Science, Inc.855 Route 301Cold SpringNY10516USA
| |
Collapse
|
29
|
Farr JN, Khosla S. Determinants of bone strength and quality in diabetes mellitus in humans. Bone 2016; 82:28-34. [PMID: 26211989 PMCID: PMC4679576 DOI: 10.1016/j.bone.2015.07.027] [Citation(s) in RCA: 130] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 07/03/2015] [Accepted: 07/19/2015] [Indexed: 12/12/2022]
Abstract
There is growing evidence that the higher fracture rate observed in patients with type 2 diabetes mellitus (T2DM) is associated with normal, or even increased, areal bone mineral density (aBMD) by DXA. This has led to the hypothesis that patients with T2DM may have abnormalities in bone microarchitecture and/or material composition - i.e., key determinants of bone "quality." Consistent with this hypothesis, several studies using high-resolution peripheral quantitative computed tomography (HRpQCT) have demonstrated preserved indices of trabecular microarchitecture but increased cortical porosity in T2DM patients. In addition, a recent study using a novel in vivo microindentation device found an impairment in a measure of bone material properties (bone material strength index, BMSi) in postmenopausal women with longstanding T2DM; notably, the reduction in BMSi was associated with chronic glycemic control, suggesting that the skeleton should be included as another target organ subject to diabetic complications. The underlying pathogenesis of skeletal fragility in T2DM remains to be defined, although high levels of advanced glycation endproducts (AGEs) may play a role. In addition, T2DM is associated with reduced bone turnover, perhaps with an imbalance between bone resorption and bone formation. Although several studies have found increased serum sclerostin levels in patients with T2DM, the role of these increased levels in mediating the observed increases in cortical porosity or reduction in BMSi remains to be defined. Thus, although bone quality appears to be impaired in T2DM, the pathogenesis of these abnormalities and their relationship to the increased fracture risk observed in these patients needs further study.
Collapse
Affiliation(s)
- Joshua N Farr
- Endocrine Research Unit and Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA.
| | - Sundeep Khosla
- Endocrine Research Unit and Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
30
|
Jenkins T, Coutts LV, D'Angelo S, Dunlop DG, Oreffo ROC, Cooper C, Harvey NC, Thurner PJ. Site-Dependent Reference Point Microindentation Complements Clinical Measures for Improved Fracture Risk Assessment at the Human Femoral Neck. J Bone Miner Res 2016; 31:196-203. [PMID: 26235931 DOI: 10.1002/jbmr.2605] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2015] [Revised: 07/27/2015] [Accepted: 07/28/2015] [Indexed: 12/27/2022]
Abstract
In contrast to traditional approaches to fracture risk assessment using clinical risk factors and bone mineral density (BMD), a new technique, reference point microindentation (RPI), permits direct assessment of bone quality; in vivo tibial RPI measurements appear to discriminate patients with a fragility fracture from controls. However, it is unclear how this relates to the site of the most clinically devastating fracture, the femoral neck, and whether RPI provides information complementary to that from existing assessments. Femoral neck samples were collected at surgery after low-trauma hip fracture (n = 46; 17 male; aged 83 [interquartile range 77-87] years) and compared, using RPI (Biodent Hfc), with 16 cadaveric control samples, free from bone disease (7 male; aged 65 [IQR 61-74] years). A subset of fracture patients returned for dual-energy X-ray absorptiometry (DXA) assessment (Hologic Discovery) and, for the controls, a micro-computed tomography setup (HMX, Nikon) was used to replicate DXA scans. The indentation depth was greater in femoral neck samples from osteoporotic fracture patients than controls (p < 0.001), which persisted with adjustment for age, sex, body mass index (BMI), and height (p < 0.001) but was site-dependent, being less pronounced in the inferomedial region. RPI demonstrated good discrimination between fracture and controls using receiver-operating characteristic (ROC) analyses (area under the curve [AUC] = 0.79 to 0.89), and a model combining RPI to clinical risk factors or BMD performed better than the individual components (AUC = 0.88 to 0.99). In conclusion, RPI at the femoral neck discriminated fracture cases from controls independent of BMD and traditional risk factors but dependent on location. The clinical RPI device may, therefore, supplement risk assessment and requires testing in prospective cohorts and comparison between the clinically accessible tibia and the femoral neck. © 2015 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Thomas Jenkins
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - Louise V Coutts
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK
| | - Stefania D'Angelo
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
| | - Douglas G Dunlop
- University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Richard O C Oreffo
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Institute for Development Sciences, Faculty of Medicine, University of Southampton, Southampton, UK
| | - Cyrus Cooper
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK.,NIHR Musculoskeletal Biomedical Research Unit, University of Oxford, Oxford, UK.,NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK.,NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Phillipp J Thurner
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Southampton, UK.,Institute for Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria
| | | |
Collapse
|
31
|
Estimation of local anisotropy of plexiform bone: Comparison between depth sensing micro-indentation and Reference Point Indentation. J Biomech 2015; 48:4073-4080. [DOI: 10.1016/j.jbiomech.2015.10.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2015] [Revised: 09/28/2015] [Accepted: 10/01/2015] [Indexed: 11/19/2022]
|
32
|
Allen MR, McNerny EM, Organ JM, Wallace JM. True Gold or Pyrite: A Review of Reference Point Indentation for Assessing Bone Mechanical Properties In Vivo. J Bone Miner Res 2015; 30:1539-50. [PMID: 26235703 PMCID: PMC4825864 DOI: 10.1002/jbmr.2603] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 07/30/2015] [Accepted: 07/30/2015] [Indexed: 11/09/2022]
Abstract
Although the gold standard for determining bones' mechanical integrity is the direct measure of mechanical properties, clinical evaluation has long relied on surrogates of mechanical properties for assessment of fracture risk. Nearly a decade ago, reference point indentation (RPI) emerged as an innovative way to potentially assess mechanical properties of bone in vivo. Beginning with the BioDent device, and then followed by the newer generation OsteoProbe, this RPI technology has been utilized in several publications. In this review we present an overview of the technology and some important details about the two devices. We also highlight select key studies, focused specifically on the in vivo application of these devices, as a way of synthesizing where the technology stands in 2015. The BioDent machine has been shown, in two clinical reports, to be able to differentiate fracture versus nonfracture patient populations and in preclinical studies to detect treatment effects that are consistent with those quantified using traditional mechanical tests. The OsteoProbe appears able to separate clinical cohorts yet there exists a lack of clarity regarding details of testing, which suggests more rigorous work needs to be undertaken with this machine. Taken together, RPI technology has shown promising results, yet much more work is needed to determine if its theoretical potential to assess mechanical properties in vivo can be realized.
Collapse
Affiliation(s)
- Matthew R Allen
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA.,Department of Medicine-Nephrology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Erin Mb McNerny
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Jason M Organ
- Department of Anatomy and Cell Biology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University Purdue University of Indianapolis, Indianapolis, IN, USA
| |
Collapse
|
33
|
Katsamenis OL, Jenkins T, Thurner PJ. Toughness and damage susceptibility in human cortical bone is proportional to mechanical inhomogeneity at the osteonal-level. Bone 2015; 76:158-68. [PMID: 25863123 DOI: 10.1016/j.bone.2015.03.020] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 03/18/2015] [Accepted: 03/27/2015] [Indexed: 01/16/2023]
Abstract
Limitations associated with current clinical fracture risk assessment tools highlight the need for increased understanding of the fracture mechanisms of the bone and, ideally, a means of assessing this in vivo. Being a multi-layered hierarchical structure, the overall properties of the bone are dictated by its structural and compositional properties over multiple length scales. In this study, we investigate the osteonal-, micro- and tissue-level mechanical behaviour of cortical bone tissue samples from young and elderly donors through atomic force microscope (AFM) cantilever-based nanoindentation, reference point microindentation (RPI) and fracture toughness experiments respectively. We demonstrate that bone's fracture toughness and crack growth resistance at the tissue-level are significantly correlated to damage susceptibility at the micro-level, and mechanical inhomogeneity between lamellae and interlamellar areas at the osteonal-level. In more detail, reduced nanoelasticity inhomogeneity of lamellar/interlamellar layers within the osteons correlated to increased indentation depth at the micro-level and an overall reduction in crack-growth toughness and fracture toughness of the tissue. Our data also suggest that deterioration of bone's mechanical properties is expressed concurrently at these three levels, and that mechanical inhomogeneity between the principal structural units of the cortical tissue holds a key role on bone's toughness behaviour. We hypothesise that the reduction in nanoelasticity inhomogeneity is--at least to some extent--responsible for the inability of the microstructure to effectively adapt to the applied load, e.g. by redistributing strains, in a non-catastrophic manner preventing damage formation and propagation. Our hypothesis is further supported by synchrotron radiation micro-computed tomography (SRμCT) data, which show that failure of tougher bone specimens is governed by increased deflection of the crack path and broadly spread damage around the crack-tip. In contrast, shorter and more direct crack paths as well as less-distributed damage were evidenced during failure of the weaker specimens. Overall, this multi-scale study highlights the importance of elasticity inhomogeneity within the osteon to the damage susceptibility and consequently to the fracture resistance of the tissue.
Collapse
Affiliation(s)
- Orestis L Katsamenis
- μVIS X-ray Imaging Centre, Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK; Bioengineering Sciences Research Group, Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK.
| | - Thomas Jenkins
- Bioengineering Sciences Research Group, Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK
| | - Philipp J Thurner
- Bioengineering Sciences Research Group, Faculty of Engineering and the Environment, University of Southampton, SO17 1BJ Southampton, UK; Institute for Lightweight Design and Structural Biomechanics, Vienna University of Technology, 1040 Vienna, Austria.
| |
Collapse
|
34
|
Granke M, Makowski AJ, Uppuganti S, Does MD, Nyman JS. Identifying Novel Clinical Surrogates to Assess Human Bone Fracture Toughness. J Bone Miner Res 2015; 30:1290-300. [PMID: 25639628 PMCID: PMC4478129 DOI: 10.1002/jbmr.2452] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 11/06/2014] [Accepted: 01/08/2015] [Indexed: 12/13/2022]
Abstract
Fracture risk does not solely depend on strength but also on fracture toughness; ie, the ability of bone material to resist crack initiation and propagation. Because resistance to crack growth largely depends on bone properties at the tissue level, including collagen characteristics, current X-ray based assessment tools may not be suitable to identify age-related, disease-related, or treatment-related changes in fracture toughness. To identify useful clinical surrogates that could improve the assessment of fracture resistance, we investigated the potential of (1)H nuclear magnetic resonance spectroscopy (NMR) and reference point indentation (RPI) to explain age-related variance in fracture toughness. Harvested from cadaveric femurs (62 human donors), single-edge notched beam (SENB) specimens of cortical bone underwent fracture toughness testing (R-curve method). NMR-derived bound water showed the strongest correlation with fracture toughness properties (r = 0.63 for crack initiation, r = 0.35 for crack growth, and r = 0.45 for overall fracture toughness; p < 0.01). Multivariate analyses indicated that the age-related decrease in different fracture toughness properties were best explained by a combination of NMR properties including pore water and RPI-derived tissue stiffness with age as a significant covariate (adjusted R(2) = 53.3%, 23.9%, and 35.2% for crack initiation, crack growth, and overall toughness, respectively; p < 0.001). These findings reflect the existence of many contributors to fracture toughness and emphasize the utility of a multimodal assessment of fracture resistance. Exploring the mechanistic origin of fracture toughness, glycation-mediated nonenzymatic collagen crosslinks and intracortical porosity are possible determinants of bone fracture toughness and could explain the sensitivity of NMR to changes in fracture toughness. Assuming fracture toughness is clinically important to the ability of bone to resist fracture, our results suggest that improvements in fracture risk assessment could potentially be achieved by accounting for water distribution (quantitative ultrashort echo time magnetic resonance imaging) and by a local measure of tissue resistance to indentation, RPI.
Collapse
Affiliation(s)
- Mathilde Granke
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Alexander J Makowski
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Mark D Does
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
- Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN, USA
- Department of Electrical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery and Rehabilitation, Vanderbilt University Medical Center, Nashville, TN, USA
- Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
35
|
Srisuwananukorn A, Allen MR, Brown DM, Wallace JM, Organ JM. In vivo reference point indentation measurement variability in skeletally mature inbred mice. BONEKEY REPORTS 2015; 4:712. [PMID: 26131362 DOI: 10.1038/bonekey.2015.81] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Accepted: 05/08/2015] [Indexed: 11/09/2022]
Abstract
Reference point indentation (RPI) was developed to measure material-level mechanical properties of bone in vivo. Studies using RPI in vivo have discriminated between human subjects with previous skeletal fractures and those without and among dogs given different anti-remodeling drugs. Recently, this technology was extended to rats, providing the first in vivo data for rodents. The goal of the present study was to perform in vivo RPI measurements in mice, the most common animal model used to study bone. Twelve 16-week-old female C57BL/6 mice were subjected to RPI (three tests) on the anterior tibia, followed by a repeat test session on the contralateral limb 28 days later. A custom MATLAB program was used to derive several outcome parameters from RPI force-displacement curves: first cycle indentation distance (ID-1st), ID increase (IDI), total ID (TID), first cycle unloading slope (US-1st) and first cycle energy dissipation (ED-1st). Data within an individual were averaged across the three tests for each time point. Within-animal variation of all RPI parameters on day 1 ranged from 12.8 to 33.4% and from 14.1 to 22.4% on day 28. Between-animal variation on day 1 ranged from 11.4% to 22.8% and from 7.5% to 24.7% on day 28. At both time points, within- and between-animals, US-1st was the least variable parameter and IDI was most variable. All parameters were nonsignificantly lower at day 28 compared with day 1. These data are important to demonstrate the feasibility of collecting bone material property data longitudinally in mice and will inform the design of future studies in terms of statistical power and appropriate sample size considerations.
Collapse
Affiliation(s)
- Andrew Srisuwananukorn
- Department of Anatomy and Cell Biology, Indiana University School of Medicine , Indianapolis, IN, USA
| | - Matthew R Allen
- Department of Anatomy and Cell Biology, Indiana University School of Medicine , Indianapolis, IN, USA
| | - Drew M Brown
- Department of Anatomy and Cell Biology, Indiana University School of Medicine , Indianapolis, IN, USA
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University-Purdue University at Indianapolis , Indianapolis, IN, USA ; Department of Orthopaedic Surgery, Indiana University School of Medicine , Indianapolis, IN, USA
| | - Jason M Organ
- Department of Anatomy and Cell Biology, Indiana University School of Medicine , Indianapolis, IN, USA
| |
Collapse
|
36
|
Beutel BG, Kennedy OD. Characterization of damage mechanisms associated with reference point indentation in human bone. Bone 2015; 75:1-7. [PMID: 25659950 DOI: 10.1016/j.bone.2015.01.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 01/22/2015] [Accepted: 01/28/2015] [Indexed: 11/22/2022]
Abstract
Measurement of bone mineral density (BMD) is the clinical gold standard in cases of compromised skeletal integrity, such as with osteoporosis. While BMD is a useful measurement to index skeletal health, it is also limited since it cannot directly assess any mechanical properties. The ability to directly assess mechanical properties of bone tissue would be clinically important. Reference point indentation (RPI) is a technology that has been designed to try and achieve this goal. While RPI has been shown to detect altered bone tissue properties, the underlying physical mechanism of these measurements has not been characterized. Thus, we designed a study whereby the contribution of (1) test cycle number and (2) test load level to RPI test-induced sub-surface damage was characterized and quantified. Standardized specimens were prepared from cadaveric human tibiae (n=6), such that 12 replicates of each testing condition could be carried out. A custom rig was fabricated to accurately position and map indentation sites. One set of tests was carried out with 1, 5, 10, 15 and 20 cycles (Max Load: 8 N, Freq: 2 Hz), and a second set of tests was carried out with Load levels of 2, 4, 6, 8 or 10 N (Cycle number: 20, Freq: 2 Hz). The RPI parameter Loading Slope (LS) was cycle dependent at 5, 10, 15 and 20 cycles (p<0.05). First Cycle Indentation Distance (ID 1st), Total Indentation Distance (TID), Mean Energy Dissipation (ED), First Cycle Unloading Slope (US 1st), Mean Unloading Slope (US) and LS were significantly different at 6, 8 and 10 N compared to 2 N (p<0.05). From the histomorphometric measurements, damage zone span was significantly different after 5, 10, 15 and 20 cycles compared with 1 cycle while indent profile width and indent profile depth were significantly different at 10, 15 and 20 cycles (p<0.05). With the load varying protocol, each of these parameters differed significantly at each increased load level (4, 6, 8, 10 N) compared with the basal level of 2 N (p<0.05). The damage area parameter in both protocols was significantly different from baseline at the three upper levels tested (i.e. 10, 15, 20 cycles and 6, 8, 10 N, in cycle and load variant protocols, respectively). Specimens were scanned by micro-computed tomography, which showed no material or microstructural differences between samples, and processed for histological analyses and damage quantification. Consistent microdamage patterns were present with evidence of damage via compaction at the indented regions. While damage in the direction of loading was established early, the damage area then increased radially with cycle number. These data help to further understand the physical manifestations of RPI parameters and will help to further facilitate its use as a clinical diagnostic tool.
Collapse
Affiliation(s)
- Bryan G Beutel
- New York University School of Medicine, Department of Orthopaedic Surgery, 301 East 17th Street, Suite 1500, NY, NY 10003, USA
| | - Oran D Kennedy
- New York University School of Medicine, Department of Orthopaedic Surgery, 301 East 17th Street, Suite 1500, NY, NY 10003, USA.
| |
Collapse
|
37
|
Variability in reference point microindentation and recommendations for testing cortical bone: location, thickness and orientation heterogeneity. J Mech Behav Biomed Mater 2015; 46:292-304. [PMID: 25837158 DOI: 10.1016/j.jmbbm.2015.02.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Revised: 02/03/2015] [Accepted: 02/07/2015] [Indexed: 11/24/2022]
Abstract
Reference Point Indentation (RPI) has been proposed as a new clinical tool to aid the diagnosis of Osteoporosis. This study has examined the performance of the tool within entire femurs to improve the understanding of the mechanical properties of bone and also to guide future RPI testing to optimize repeatability of results obtained using the technique. Human, bovine, porcine and rat femurs were indented along three longitudinal axes: anterior and posterior: medial and lateral as well as around the circumference of the femoral head and neck. Cortical and subchondral bone thickness was measured using CT and radiography. The study shows that in some samples, bone is too thin to support the high loads applied with the technique and in these cases, RPI values are highly influenced by thickness. The technique will be useful in the mid-shaft region where cortical thickness is greatest, providing previously established guidelines are followed to optimize measurement repeatability, including performing multiple measurements per sample and investigating multiple samples. The study has also provided evidence that RPI values vary significantly with test site, hence mechanical properties should not be inferred from RPI findings alone away from the test site, even within the same bone. In conclusion, RPI appears to be a useful tool for scientific investigation; however further work is required to examine the feasibility of using RPI for assessing differences between healthy and diseased bone in a clinical setting.
Collapse
|
38
|
Jenkins T, Coutts LV, Dunlop DG, Oreffo ROC, Cooper C, Harvey NC, Thurner PJ. Variability in reference point microindentation and recommendations for testing cortical bone: maximum load, sample orientation, mode of use, sample preparation and measurement spacing. J Mech Behav Biomed Mater 2015; 42:311-24. [PMID: 25455607 DOI: 10.1016/j.jmbbm.2014.09.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Revised: 09/19/2014] [Accepted: 09/27/2014] [Indexed: 10/24/2022]
Abstract
Reference Point Indentation (RPI) is a novel microindentation tool that has emerging clinical potential for the assessment of fracture risk as well as use as a laboratory tool for straight-forward mechanical characterisation of bone. Despite increasing use of the tool, little research is available to advise the set-up of testing protocols or optimisation of testing parameters. Here we consider five such parameters: maximum load, sample orientation, mode of use, sample preparation and measurement spacing, to investigate how they affect the Indentation Distance Increase (IDI), the most published measurement parameter associated with the RPI device. The RPI tool was applied to bovine bone; indenting in the proximal midshaft of five femora and human bone; indenting five femoral heads and five femoral neck samples. Based on the findings of these studies we recommend the following as the best practice. (1) Repeat measurements should be utilised to reduce the coefficient of variation (e.g. 8-15 repeats to achieve a 5-10% error, however the 3-5 measurements used here gives a 15-20% error). (2) IDI is dependent on maximum load (r=0.45 on the periosteal surface and r=0.94 on the machined surface, p<0.05), mode of use (i.e. comparing the device held freehand compared to fixed in its stand, p=0.04) and surface preparation (p=0.004) so these should be kept consistent throughout testing. Though sample orientation appears to have minimal influence on IDI (p>0.05), care should also be taken in combining measurements from different orientations. (3) The coefficient of variation is higher (p=0.04) when holding the device freehand, so it should ideally be kept supported in its stand. (4) Removing the periosteum (p=0.04) and machining the surface of the bone (p=0.08) reduces the coefficient of variation, so should be performed where practical. (5) There is a hyperbolic relationship between thickness and IDI (p<0.001) with a sample thickness 10 fold greater than the maximum indentation depth recommended, to ensure a representative measurement. (6) Measurement spacing does not appear to influence the IDI (p>0.05), so it can be as low as 500 µm. By following these recommendations, RPI users can minimise the potential confounding effects associated with the variables investigated here and reduce the coefficient of variation, hence achieving more consistent testing. This optimisation of the technique enhances both the clinical and laboratory potential of the tool.
Collapse
Affiliation(s)
- T Jenkins
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Highfield, Southampton SO17 1BJ, UK
| | - L V Coutts
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Highfield, Southampton SO17 1BJ, UK
| | - D G Dunlop
- University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - R O C Oreffo
- Bone and Joint Research Group, Centre for Human Development, Stem Cells and Regeneration, Institute for Development Sciences, Faculty of Medicine, University of Southampton, Southampton, UK
| | - C Cooper
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK; NIHR Musculoskeletal Biomedical Research Unit, University of Oxford, Oxford, UK; NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, UK
| | - N C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK; NIHR Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, UK
| | - P J Thurner
- Bioengineering Science Research Group, Faculty of Engineering and the Environment, University of Southampton, Highfield, Southampton SO17 1BJ, UK; Institute for Lightweight Design and Structural Biomechanics, Vienna University of Technology, Gußhausstraße 27-29, 1040 Vienna, Austria.
| |
Collapse
|
39
|
Milovanovic P, Zimmermann EA, Riedel C, vom Scheidt A, Herzog L, Krause M, Djonic D, Djuric M, Püschel K, Amling M, Ritchie RO, Busse B. Multi-level characterization of human femoral cortices and their underlying osteocyte network reveal trends in quality of young, aged, osteoporotic and antiresorptive-treated bone. Biomaterials 2015; 45:46-55. [PMID: 25662494 DOI: 10.1016/j.biomaterials.2014.12.024] [Citation(s) in RCA: 78] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 12/11/2014] [Accepted: 12/20/2014] [Indexed: 01/04/2023]
Abstract
Characterization of bone's hierarchical structure in aging, disease and treatment conditions is imperative to understand the architectural and compositional modifications to the material and its mechanical integrity. Here, cortical bone sections from 30 female proximal femurs - a frequent fracture site - were rigorously assessed to characterize the osteocyte lacunar network, osteon density and patterns of bone matrix mineralization by backscatter-electron imaging and Fourier-transform infrared spectroscopy in relation to mechanical properties obtained by reference-point indentation. We show that young, healthy bone revealed the highest resistance to mechanical loading (indentation) along with higher mineralization and preserved osteocyte-lacunar characteristics. In contrast, aging and osteoporosis significantly alter bone material properties, where impairment of the osteocyte-lacunar network was evident through accumulation of hypermineralized osteocyte lacunae with aging and even more in osteoporosis, highlighting increased osteocyte apoptosis and reduced mechanical competence. But antiresorptive treatment led to fewer mineralized lacunae and fewer but larger osteons signifying rejuvenated bone. In summary, multiple structural and compositional changes to the bone material were identified leading to decay or maintenance of bone quality in disease, health and treatment conditions. Clearly, antiresorptive treatment reflected favorable effects on the multifunctional osteocytic cells that are a prerequisite for bone's structural, metabolic and mechanosensory integrity.
Collapse
Affiliation(s)
- Petar Milovanovic
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany; Laboratory for Anthropology, Institute of Anatomy, Faculty of Medicine, University of Belgrade, Dr Subotica 4/2, 11000 Belgrade, Serbia
| | - Elizabeth A Zimmermann
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Christoph Riedel
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Annika vom Scheidt
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Lydia Herzog
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Matthias Krause
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Danijela Djonic
- Laboratory for Anthropology, Institute of Anatomy, Faculty of Medicine, University of Belgrade, Dr Subotica 4/2, 11000 Belgrade, Serbia
| | - Marija Djuric
- Laboratory for Anthropology, Institute of Anatomy, Faculty of Medicine, University of Belgrade, Dr Subotica 4/2, 11000 Belgrade, Serbia
| | - Klaus Püschel
- Department of Forensic Medicine, University Medical Center Hamburg-Eppendorf, Butenfeld 34, 22529 Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany
| | - Robert O Ritchie
- Department of Materials Science and Engineering, University of California, Berkeley, USA; Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA
| | - Björn Busse
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529 Hamburg, Germany; Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA.
| |
Collapse
|
40
|
Lloyd AA, Wang ZX, Donnelly E. Multiscale contribution of bone tissue material property heterogeneity to trabecular bone mechanical behavior. J Biomech Eng 2015; 137:1935360. [PMID: 25383615 PMCID: PMC4296240 DOI: 10.1115/1.4029046] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2014] [Revised: 11/05/2014] [Accepted: 11/12/2014] [Indexed: 11/08/2022]
Abstract
Heterogeneity of material properties is an important potential contributor to bone fracture resistance because of its putative contribution to toughness, but establishing the contribution of heterogeneity to fracture risk is still in an incipient stage. Experimental studies have demonstrated changes in distributions of compositional and nanomechanical properties with fragility fracture history, disease, and pharmacologic treatment. Computational studies have demonstrated that models with heterogeneous material properties predict apparent stiffness moderately better than homogeneous models and show greater energy dissipation. Collectively, these results suggest that microscale material heterogeneity affects not only microscale mechanics but also structural performance at larger length scales.
Collapse
Affiliation(s)
- Ashley A. Lloyd
- Department of Materials Scienceand Engineering,Cornell University,B60 Bard Hall,Ithaca, NY 14853e-mail:
| | - Zhen Xiang Wang
- Department of Materials Scienceand Engineering,Cornell University,B60 Bard Hall,Ithaca, NY 14853e-mail:
| | - Eve Donnelly
- Assistant ProfessorDepartment of Materials Scienceand Engineering,Cornell University,227 Bard Hall,Ithaca, NY 14853
- Hospital for Special Surgery,535 E. 70th Street,New York, NY 10021e-mail:
| |
Collapse
|
41
|
Carriero A, Bruse JL, Oldknow KJ, Millán JL, Farquharson C, Shefelbine SJ. Reference point indentation is not indicative of whole mouse bone measures of stress intensity fracture toughness. Bone 2014; 69:174-9. [PMID: 25280470 PMCID: PMC4228060 DOI: 10.1016/j.bone.2014.09.020] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2014] [Revised: 09/19/2014] [Accepted: 09/22/2014] [Indexed: 01/22/2023]
Abstract
Bone fragility is a concern for aged and diseased bone. Measuring bone toughness and understanding fracture properties of the bone are critical for predicting fracture risk associated with age and disease and for preclinical testing of therapies. A reference point indentation technique (BioDent) has recently been developed to determine bone's resistance to fracture in a minimally invasive way by measuring the indentation distance increase (IDI) between the first and last indentations over cyclic indentations in the same position. In this study, we investigate the relationship between fracture toughness KC and reference point indentation parameters (i.e. IDI, total indentation distance (TID) and creep indentation distance (CID)) in bones from 38 mice from six types (C57Bl/6, Balb, oim/oim, oim/+, Phospho1(-/-) and Phospho1 wild type counterpart). These mice bone are models of healthy and diseased bone spanning a range of fracture toughness from very brittle (oim/oim) to ductile (Phospho1(-/-)). Left femora were dissected, notched and tested in 3-point bending until complete failure. Contralateral femora were dissected and indented in 10 sites of their anterior and posterior shaft surface over 10 indentation cycles. IDI, TID and CID were measured. Results from this study suggest that reference point indentation parameters are not indicative of stress intensity fracture toughness in mouse bone. In particular, the IDI values at the anterior mid-diaphysis across mouse types overlapped, making it difficult to discern differences between mouse types, despite having extreme differences in stress intensity based toughness measures. When more locations of indentation were considered, the normalised IDIs could distinguish between mouse types. Future studies should investigate the relationship of the reference point indentation parameters for mouse bone in other material properties of the bone tissue in order to determine their use for measuring bone quality.
Collapse
Affiliation(s)
| | - Jan L Bruse
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Karla J Oldknow
- The Roslin Institute and Royal School of Veterinary Studies, The University of Edinburgh, Easter Bush, Midlothian EH25 9RG, UK
| | - José Luis Millán
- Sanford Children's Health Research Center, Sanford-Burnham Medical Research Institute, La Jolla, CA 92037, USA
| | - Colin Farquharson
- The Roslin Institute and Royal School of Veterinary Studies, The University of Edinburgh, Easter Bush, Midlothian EH25 9RG, UK
| | | |
Collapse
|
42
|
Eriksen EF. Commentary on sclerostin deficiency is linked to altered bone composition. J Bone Miner Res 2014; 29:2141-3. [PMID: 25158054 DOI: 10.1002/jbmr.2346] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Affiliation(s)
- Erik Fink Eriksen
- Department of Endocrinology, Morbid Obesity, and Preventative Medicine, Oslo University Hospital, Oslo, Norway
| |
Collapse
|
43
|
Amugongo SK, Yao W, Jia J, Dai W, Lay YAE, Jiang L, Harvey D, Zimmermann EA, Schaible E, Dave N, Ritchie RO, Kimmel DB, Lane NE. Effect of sequential treatments with alendronate, parathyroid hormone (1-34) and raloxifene on cortical bone mass and strength in ovariectomized rats. Bone 2014; 67:257-68. [PMID: 25016965 PMCID: PMC4157684 DOI: 10.1016/j.bone.2014.04.033] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2014] [Revised: 04/03/2014] [Accepted: 04/16/2014] [Indexed: 01/10/2023]
Abstract
UNLABELLED Anti-resorptive and anabolic agents are often prescribed for the treatment of osteoporosis continuously or sequentially for many years. However their impact on cortical bone quality and bone strength is not clear. METHODS Six-month old female rats were either sham operated or ovariectomized (OVX). OVX rats were left untreated for two months and then were treated with vehicle (Veh), hPTH (1-34) (PTH), alendronate (Aln), or raloxifene (Ral) sequentially for three month intervals, for a total of three periods. Mid-tibial cortical bone architecture, mass, mineralization, and strength were measured on necropsy samples obtained after each period. Bone indentation properties were measured on proximal femur necropsy samples. RESULTS Eight or more months of estrogen deficiency in rats resulted in decreased cortical bone area and thickness. Treatment with PTH for 3months caused the deposition of endocortical lamellar bone that increased cortical bone area, thickness, and strength. These improvements were lost when PTH was withdrawn without followup treatment, but were maintained for the maximum times tested, six months with Ral and three months with Aln. Pre-treatment with anti-resorptives was also somewhat successful in ultimately preserving the additional endocortical lamellar bone formed under PTH treatment. These treatments did not affect bone indentation properties. SUMMARY Sequential therapy that involved both PTH and anti-resorptive agents was required to achieve lasting improvements in cortical area, thickness, and strength in OVX rats. Anti-resorptive therapy, either prior to or following PTH, was required to preserve gains attributable to an anabolic agent.
Collapse
Affiliation(s)
- Sarah K Amugongo
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Wei Yao
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Junjing Jia
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Weiwei Dai
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Yu-An E Lay
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Li Jiang
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA
| | - Danielle Harvey
- Division of Biostatistics, Department of Public Health Sciences, University of California, Davis, CA 95616, USA
| | - Elizabeth A Zimmermann
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Eric Schaible
- Experimental Systems Group, Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Neil Dave
- Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
| | - Robert O Ritchie
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA; Department of Materials Science and Engineering, University of California, Berkeley, CA 94720, USA
| | - Donald B Kimmel
- Osteoporosis Research Center, School of Medicine, Creighton University, Omaha, NE 68131, USA
| | - Nancy E Lane
- Musculoskeletal Research Unit, Department of Medicine, University of California Davis Medical Center, Sacramento, CA 95817, USA.
| |
Collapse
|
44
|
Granke M, Coulmier A, Uppuganti S, Gaddy JA, Does MD, Nyman JS. Insights into reference point indentation involving human cortical bone: sensitivity to tissue anisotropy and mechanical behavior. J Mech Behav Biomed Mater 2014; 37:174-85. [PMID: 24929851 DOI: 10.1016/j.jmbbm.2014.05.016] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 05/13/2014] [Accepted: 05/17/2014] [Indexed: 01/20/2023]
Abstract
Reference point indentation (RPI) is a microindentation technique involving 20 cycles of loading in "force-control" that can directly assess a patient׳s bone tissue properties. Even though preliminary clinical studies indicate a capability for fracture discrimination, little is known about what mechanical behavior the various RPI properties characterize and how these properties relate to traditional mechanical properties of bone. To address this, the present study investigated the sensitivity of RPI properties to anatomical location and tissue organization as well as examined to what extent RPI measurements explain the intrinsic mechanical properties of human cortical bone. Multiple indents with a target force of 10N were done in 2 orthogonal directions (longitudinal and transverse) per quadrant (anterior, medial, posterior, and lateral) of the femoral mid-shaft acquired from 26 donors (25-101 years old). Additional RPI measurements were acquired for 3 orthogonal directions (medial only). Independent of age, most RPI properties did not vary among these locations, but they did exhibit transverse isotropy such that resistance to indentation is greater in the longitudinal (axial) direction than in the transverse direction (radial or circumferential). Next, beam specimens (~2mm×5mm×40mm) were extracted from the medial cortex of femoral mid-shafts, acquired from 34 donors (21-99 years old). After monotonically loading the specimens in three-point bending to failure, RPI properties were acquired from an adjacent region outside the span. Indent direction was orthogonal to the bending axis. A significant inverse relationship was found between resistance to indentation and the apparent-level mechanical properties. Indentation distance increase (IDI) and a linear combination of IDI and the loading slope, averaged over cycles 3 through 20, provided the best explanation of the variance in ultimate stress (r(2)=0.25, p=0.003) and toughness (r(2)=0.35, p=0.004), respectively. With a transverse isotropic behavior akin to tissue hardness and modulus as determined by micro- and nano-indentation and a significant association with toughness, RPI properties are likely influenced by both elastic and plastic behavior of bone tissue.
Collapse
Affiliation(s)
- Mathilde Granke
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University, Nashville, TN 37232, United States
| | - Aurélie Coulmier
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University, Nashville, TN 37232, United States; Polytech Marseille, Marseille 13288, France
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University, Nashville, TN 37232, United States
| | - Jennifer A Gaddy
- Department of Medicine, Vanderbilt University, Nashville, TN 37232, United States; Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, United States
| | - Mark D Does
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, United States; Institute of Imaging Science, Vanderbilt University, Nashville, TN 37232, United States; Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, TN 37232, United States; Department of Electrical Engineering, Vanderbilt University, Nashville, TN 37232, United States
| | - Jeffry S Nyman
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University, Nashville, TN 37232, United States; Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, United States; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, United States; Center for Bone Biology, Vanderbilt University, Nashville, TN 37232, United States.
| |
Collapse
|
45
|
Variability of in vivo reference point indentation in skeletally mature inbred rats. J Biomech 2014; 47:2504-7. [PMID: 24856912 DOI: 10.1016/j.jbiomech.2014.04.035] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 04/17/2014] [Accepted: 04/21/2014] [Indexed: 11/22/2022]
Abstract
Reference point indentation (RPI) has emerged as a novel tool to measure material-level biomechanical properties in vivo. Human studies have been able to differentiate fracture versus non-fracture patients while a dog study has shown the technique can differentiate drug treatment effects. The goal of this study was to extend this technology to the in vivo measurement of rats, one of the most common animal models used to study bone, with assessment of intra- and inter-animal variability. Seventy-two skeletally mature male Sprague-Dawley rats were subjected to in vivo RPI on the region between the tibial diaphysis and proximal metaphysis. RPI data were assessed using a custom MATLAB program to determine several outcome parameters, including first cycle indentation distance (ID-1st), indentation distance increase (IDI), total indentation distance (TID), first cycle unloading slope (US-1st), and first cycle energy dissipation (ED-1st). Intra-animal variability ranged from 13% to 21% with US-1st and Tot Ed 1st-L being the least variable properties and IDI the most highly variable. Inter-animal variability ranged from 16% (US-1st) to 25% (ED-1st and IDI). Based on these data, group size estimates would need to range from 9 to 18/group to achieve sufficient power for detecting a 25% difference in a two-group experiment. Repeat tests on the contralateral limb of a small cohort of animals (n=17) showed non-significant differences over 28 days ranging from -6% to -18%. These results provide important data on RPI variability (intra- and inter-animal) in rats that can be used to properly power future experiments using this technique.
Collapse
|
46
|
Jepsen KJ, Schlecht SH. Biomechanical mechanisms: resolving the apparent conundrum of why individuals with type II diabetes show increased fracture incidence despite having normal BMD. J Bone Miner Res 2014; 29:784-6. [PMID: 24496824 PMCID: PMC4786737 DOI: 10.1002/jbmr.2189] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Karl J Jepsen
- Department of Orthopaedic Surgery, The University of Michigan, Ann Arbor, MI, USA
| | | |
Collapse
|
47
|
Torres-del-Pliego E, Vilaplana L, Güerri-Fernández R, Diez-Pérez A. Measuring bone quality. Curr Rheumatol Rep 2014; 15:373. [PMID: 24072603 DOI: 10.1007/s11926-013-0373-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Osteoporosis is defined as a reduction in bone mass and impairment of bone quality that lead to bone fragility and fracture risk. Bone quality includes a hierarchy of properties from macroscopic to nanoscale level. Several techniques have been developed in an attempt to measure these non-density properties. Densitometry, high-resolution images (radiography, CT scan), and MRI can measure the geometry and microarchitecture of bone. Tissue mineralization and composition can be assessed by use of microradiography, Fourier-transform infrared spectroscopy, or Raman microspectroscopy. Finite-element analysis is an image-based method that enables calculation of bone strength. More recently, microindentation has enabled direct estimation of bone material strength, measured in the cortical bone of the tibia. Most of these techniques are of limited use to clinics, although finite-element analysis and microindentation have high potential for clinical use and can enable more comprehensive and accurate evaluation of bone fragility and fracture susceptibility.
Collapse
Affiliation(s)
- Elisa Torres-del-Pliego
- Department of Medicine, Hospital del Mar-IMIM, Universitat Autònoma de Barcelona, RETICEF, Instituto Carlos III, Catalonia, Spain,
| | | | | | | |
Collapse
|
48
|
Milovanovic P, Rakocevic Z, Djonic D, Zivkovic V, Hahn M, Nikolic S, Amling M, Busse B, Djuric M. Nano-structural, compositional and micro-architectural signs of cortical bone fragility at the superolateral femoral neck in elderly hip fracture patients vs. healthy aged controls. Exp Gerontol 2014; 55:19-28. [PMID: 24614625 DOI: 10.1016/j.exger.2014.03.001] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2013] [Revised: 02/18/2014] [Accepted: 03/02/2014] [Indexed: 12/13/2022]
Abstract
To unravel the origins of decreased bone strength in the superolateral femoral neck, we assessed bone structural features across multiple length scales at this cortical fracture initiating region in postmenopausal women with hip fracture and in aged-matched controls. Our combined methodological approach encompassed atomic force microscopy (AFM) characterization of cortical bone nano-structure, assessment of mineral content/distribution via quantitative backscattered electron imaging (qBEI), measurement of bone material properties by reference point indentation, as well as evaluation of cortical micro-architecture and osteocyte lacunar density. Our findings revealed a wide range of differences between the fracture group and the controls, suggesting a number of detrimental changes at various levels of cortical bone hierarchical organization that may render bone fragile. Namely, mineral crystals at external cortical bone surfaces of the fracture group were larger (65.22nm±41.21nm vs. 36.75nm±18.49nm, p<0.001), and a shift to a higher mineral content and more homogenous mineralization profile as revealed via qBEI were found in the bone matrix of the fracture group. Fracture cases showed nearly 35% higher cortical porosity and showed significantly reduced osteocyte lacunar density compared to controls (226±27 vs. 247±32#/mm(2), p=0.05). Along with increased crystal size, a shift towards higher mineralization and a tendency to increased cortical porosity and reduced osteocyte lacunar number delineate that cortical bone of the superolateral femoral neck bears distinct signs of fragility at various levels of its structural organization. These results contribute to the understanding of hierarchical bone structure changes in age-related fragility.
Collapse
Affiliation(s)
- Petar Milovanovic
- Laboratory for Anthropology, Institute of Anatomy, School of Medicine, University of Belgrade, 4/2 Dr Subotica, 11000 Belgrade, Serbia; Department of Osteology & Biomechanics, University Medical Center Hamburg-Eppendorf, 59 Lottestr., D-22529 Hamburg, Germany.
| | - Zlatko Rakocevic
- Laboratory for Atomic Physics, Institute of Nuclear Sciences Vinca, University of Belgrade, 11001 Belgrade, Serbia.
| | - Danijela Djonic
- Laboratory for Anthropology, Institute of Anatomy, School of Medicine, University of Belgrade, 4/2 Dr Subotica, 11000 Belgrade, Serbia.
| | - Vladimir Zivkovic
- Institute of Forensic Medicine, School of Medicine, University of Belgrade, 31a Deligradska, 11000 Belgrade, Serbia.
| | - Michael Hahn
- Department of Osteology & Biomechanics, University Medical Center Hamburg-Eppendorf, 59 Lottestr., D-22529 Hamburg, Germany.
| | - Slobodan Nikolic
- Institute of Forensic Medicine, School of Medicine, University of Belgrade, 31a Deligradska, 11000 Belgrade, Serbia.
| | - Michael Amling
- Department of Osteology & Biomechanics, University Medical Center Hamburg-Eppendorf, 59 Lottestr., D-22529 Hamburg, Germany.
| | - Bjoern Busse
- Department of Osteology & Biomechanics, University Medical Center Hamburg-Eppendorf, 59 Lottestr., D-22529 Hamburg, Germany.
| | - Marija Djuric
- Laboratory for Anthropology, Institute of Anatomy, School of Medicine, University of Belgrade, 4/2 Dr Subotica, 11000 Belgrade, Serbia.
| |
Collapse
|
49
|
Setters A, Jasiuk I. Towards a standardized reference point indentation testing procedure. J Mech Behav Biomed Mater 2014; 34:57-65. [PMID: 24556325 DOI: 10.1016/j.jmbbm.2014.01.012] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 01/16/2014] [Accepted: 01/18/2014] [Indexed: 11/30/2022]
Abstract
We study the reference point indentation (RPI) technique which has a potential to directly measure mechanical properties of bone in patients. More specifically, we tested 6 month swine femoral cortical bone at mid-diaphysis region to investigate the effect of several testing variables on the RPI outputs. They include the force magnitude, preconditioning, variation within a sample and between samples, number of cycles, indentation surface (transverse versus longitudinal, polished versus unpolished), and micro-computed tomography radiation exposure. The force magnitude variation test shows that all RPI parameters increase linearly with the increasing force magnitude except the indentation distance increase which shows a cubic trend with a plateau for force magnitudes between 4N and 8N. Preconditioning does not affect the trends for a force magnitude variation test. The cycle variation test shows that most RPI parameters reach either a maximum or minimum at 15-20 cycles. Transverse surface measurements are more consistent than the longitudinal surface measurements, but a rough surface and periosteum on the longitudinal surface could account for this difference. Exposure to the micro-computed tomography radiation in general does not have effect on the RPI measurements. For the 6 month swine femoral cortical bone, testing using 6N force and 20 cycles with preconditioning on an unpolished longitudinal surface is recommended. This study advances our knowledge on how the RPI testing variables influence the RPI outputs and provides guidance on the RPI measurements. It may also serve as a framework for developing a standardized testing procedure for the RPI technique.
Collapse
Affiliation(s)
- Alexander Setters
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 W. Green Street, Urbana, IL 61801-2906, USA
| | - Iwona Jasiuk
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 W. Green Street, Urbana, IL 61801-2906, USA.
| |
Collapse
|
50
|
Randall C, Bridges D, Guerri R, Nogues X, Puig L, Torres E, Mellibovsky L, Hoffseth K, Stalbaum T, Srikanth A, Weaver JC, Rosen S, Barnard H, Brimer D, Proctor A, Candy J, Saldana C, Chandrasekar S, Lescun T, Nielson CM, Orwoll E, Herthel D, Kopeikin H, Yang HTY, Farr JN, McCready L, Khosla S, Diez-Perez A, Hansma PK. Applications of a New Handheld Reference Point Indentation Instrument Measuring Bone Material Strength. J Med Device 2013; 7:410051-410056. [PMID: 24115973 PMCID: PMC3792445 DOI: 10.1115/1.4024829] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2012] [Revised: 06/03/2013] [Indexed: 01/23/2023] Open
Abstract
A novel, hand-held Reference Point Indentation (RPI) instrument, measures how well the bone of living patients and large animals resists indentation. The results presented here are reported in terms of Bone Material Strength, which is a normalized measure of how well the bone resists indentation, and is inversely related to the indentation distance into the bone. We present examples of the instrument's use in: (1) laboratory experiments on bone, including experiments through a layer of soft tissue, (2) three human clinical trials, two ongoing in Barcelona and at the Mayo Clinic, and one completed in Portland, OR, and (3) two ongoing horse clinical trials, one at Purdue University and another at Alamo Pintado Stables in California. The instrument is capable of measuring consistent values when testing through soft tissue such as skin and periosteum, and does so handheld, an improvement over previous Reference Point Indentation instruments. Measurements conducted on horses showed reproducible results when testing the horse through tissue or on bare bone. In the human clinical trials, reasonable and consistent values were obtained, suggesting the Osteoprobe® is capable of measuring Bone Material Strength in vivo, but larger studies are needed to determine the efficacy of the instrument's use in medical diagnosis.
Collapse
|