Yoshida E, Yamaya T. PET detectors with depth-of-interaction and time-of-flight capabilities. Radiol Phys Technol 2024; 17:596-609. [PMID: 38888821 DOI: 10.1007/s12194-024-00821-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Revised: 06/09/2024] [Accepted: 06/09/2024] [Indexed: 06/20/2024]
Abstract
In positron emission tomography (PET), measurements of depth-of-interaction (DOI) information and time-of-flight (TOF) information are important. DOI information reduces the parallax error, and TOF information reduces noise by measuring the arrival time difference of the annihilation photons. Historically, these have been studied independently, and there has been less implementation of both DOI and TOF capabilities because previous DOI detectors did not have good TOF resolution. However, recent improvements in PET detector performance have resulted in commercial PET scanners achieving a coincidence resolving time of around 200 ps, which result in an effect even for small objects. This means that TOF information can now be utilized even for a brain PET scanner, which also requires DOI information. Therefore, various methods have been proposed to obtain better DOI and TOF information. In addition, the cost of PET detectors is also an important factor to consider, since several hundred detectors are used per PET scanner. In this paper, we review the latest DOI-TOF detectors including the history of detector development. When put into practical use, these DOI-TOF detectors are expected to contribute to the improvement of imaging performance in brain PET scanners.
Collapse
Affiliation(s)
- Eiji Yoshida
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan.
| | - Taiga Yamaya
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, Japan
| |
Collapse
|
2
|
Arabi H, Manesh AS, Zaidi H. Innovations in dedicated PET instrumentation: from the operating room to specimen imaging. Phys Med Biol 2024; 69:11TR03. [PMID: 38744305 DOI: 10.1088/1361-6560/ad4b92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/14/2024] [Indexed: 05/16/2024]
Abstract
This review casts a spotlight on intraoperative positron emission tomography (PET) scanners and the distinctive challenges they confront. Specifically, these systems contend with the necessity of partial coverage geometry, essential for ensuring adequate access to the patient. This inherently leans them towards limited-angle PET imaging, bringing along its array of reconstruction and geometrical sensitivity challenges. Compounding this, the need for real-time imaging in navigation systems mandates rapid acquisition and reconstruction times. For these systems, the emphasis is on dependable PET image reconstruction (without significant artefacts) while rapid processing takes precedence over the spatial resolution of the system. In contrast, specimen PET imagers are unburdened by the geometrical sensitivity challenges, thanks to their ability to leverage full coverage PET imaging geometries. For these devices, the focus shifts: high spatial resolution imaging takes precedence over rapid image reconstruction. This review concurrently probes into the technical complexities of both intraoperative and specimen PET imaging, shedding light on their recent designs, inherent challenges, and technological advancements.
Collapse
Affiliation(s)
- Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Abdollah Saberi Manesh
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700 RB Groningen, The Netherlands
- Department of Nuclear Medicine, University of Southern Denmark, 500 Odense, Denmark
- University Research and Innovation Center, Óbuda University, Budapest, Hungary
| |
Collapse
|
3
|
Zeng X, Zhang Z, Li D, Huang X, Wang Z, Wang Y, Zhou W, Wang P, Zhu M, Wei Q, Gong H, Wei L. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method. Phys Med Biol 2024; 69:085003. [PMID: 38484392 DOI: 10.1088/1361-6560/ad3417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 03/14/2024] [Indexed: 04/04/2024]
Abstract
Objective.Monolithic crystal detectors are increasingly being applied in positron emission tomography (PET) devices owing to their excellent depth-of-interaction (DOI) resolution capabilities and high detection efficiency. In this study, we constructed and evaluated a dual-ended readout monolithic crystal detector based on a multiplexing method.Approach.We employed two 12 × 12 silicon photomultiplier (SiPM) arrays for readout, and the signals from the 12 × 12 array were merged into 12 X and 12 Y channels using channel multiplexing. In 2D reconstruction, three methods based on the centre of gravity (COG) were compared, and the concept of thresholds was introduced. Furthermore, a light convolutional neural network (CNN) was employed for testing. To enhance depth localization resolution, we proposed a method by utilizing the mutual information from both ends of the SiPMs. The source width and collimation effect were simulated using GEANT4, and the intrinsic spatial resolution was separated from the measured values.Main results.At an operational voltage of 29 V for the SiPM, an energy resolution of approximately 12.5 % was achieved. By subtracting a 0.8 % threshold from the total energy in every channel, a 2D spatial resolution of approximately 0.90 mm full width at half maximum (FWHM) can be obtained. Furthermore, a higher level of resolution, approximately 0.80 mm FWHM, was achieved using a CNN, with some alleviation of edge effects. With the proposed DOI method, a significant 1.36 mm FWHM average DOI resolution can be achieved. Additionally, it was found that polishing and black coating on the crystal surface yielded smaller edge effects compared to a rough surface with a black coating.Significance.The introduction of a threshold in COG method and a dual-ended readout scheme can lead to excellent spatial resolution for monolithic crystal detectors, which can help to develop PET systems with both high sensitivity and high spatial resolution.
Collapse
Affiliation(s)
- Xiangtao Zeng
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhiming Zhang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Daowu Li
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Xianchao Huang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhuoran Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Yingjie Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Wei Zhou
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Peilin Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Meiling Zhu
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Qing Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Huixing Gong
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Long Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| |
Collapse
|
4
|
Weng N, Wei B, Li G, Yin R, Xin W, Liu C, Li H, Shao C, Jiang T, Wang X. Fluorescence and magnetic resonance imaging of ONL-93 cells in a rat model of ischemic. Magn Reson Imaging 2024; 107:111-119. [PMID: 38185391 DOI: 10.1016/j.mri.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 07/04/2023] [Accepted: 12/28/2023] [Indexed: 01/09/2024]
Abstract
OBJECTIVES The current methods for detecting myelin changes in ischemic stroke are indirect and cannot accurately reflect their status. This study aimed to develop a novel fluorescent-magnetic resonance dual-modal molecular imaging probe for direct imaging of myelin. METHODS Compounds 7a and 7b were synthesized by linking the MeDAS group and Gadolinium (III) 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate. Compound 7a was selected for characterization and further study. Cell uptake, cytotoxicity, and magnetic resonance imaging scans were performed on cells. In vitro experiments on frozen brain sections from 7-day-old, 8-week-old, and ischemic stroke rats were compared with commercially available Luxol Fast Blue staining. After HPLC and MR scanning, brain tissue was soaked in 7a and scanned using T1WI and T1maps sequences. RESULTS Spectrophotometer results showed that compounds 7a and 7b had fluorescent properties. MR scans indicated that the compounds had contrast agent properties. Cells could uptake 7a and exhibited high signals in imaging scans. Compound 7a brain tissue staining showed more fluorescence in myelin-rich regions and identified injury sites in ischemic stroke rats. MR scanning of brain sections provided clear myelin contrast. CONCLUSION A novel fluorescent-magnetic resonance dual-modal molecular imaging probe for direct imaging of myelin was successfully developed and tested in rats with ischemic stroke. These findings provide new insights for the clinical diagnosis of demyelinating diseases.
Collapse
Affiliation(s)
- Na Weng
- Department of Nuclear medicine, Binzhou Medical University Hospital, Binzhou, Shandong 256603, China
| | - Bin Wei
- Key Laboratory of Marine Drugs, Chinese Ministry of Education, School of Medicine and Pharmacy, Ocean University of China, Qingdao 266003, China
| | - Guodong Li
- Department of Nuclear medicine, Binzhou Medical University Hospital, Binzhou, Shandong 256603, China
| | - Ruijuan Yin
- Key Laboratory of Marine Drugs, Chinese Ministry of Education, School of Medicine and Pharmacy, Ocean University of China, Qingdao 266003, China
| | - Wenbin Xin
- Department of Nuclear medicine, Binzhou Medical University Hospital, Binzhou, Shandong 256603, China
| | - Caiyun Liu
- Department of Nuclear medicine, Binzhou Medical University Hospital, Binzhou, Shandong 256603, China
| | - Hao Li
- School of Medical Imaging, Binzhou Medical University, Yantai, Shandong 264003, China
| | - Cuijie Shao
- Medical Research Center, Binzhou Medical University Hospital, Binzhou 256600, China.
| | - Tao Jiang
- Key Laboratory of Marine Drugs, Chinese Ministry of Education, School of Medicine and Pharmacy, Ocean University of China, Qingdao 266003, China.
| | - Xu Wang
- Department of Nuclear medicine, Binzhou Medical University Hospital, Binzhou, Shandong 256603, China.
| |
Collapse
|
5
|
Cheng L, Lyu Z, Liu H, Wu J, Jia C, Wu Y, Ji Y, Jiang N, Ma T, Liu Y. Efficient image reconstruction for a small animal PET system with dual-layer-offset detector design. Med Phys 2024; 51:2772-2787. [PMID: 37921396 DOI: 10.1002/mp.16814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 10/10/2023] [Accepted: 10/10/2023] [Indexed: 11/04/2023] Open
Abstract
BACKGROUND A compact PET/SPECT/CT system Inliview-3000B has been developed to provide multi-modality information on small animals for biomedical research. Its PET subsystem employed a dual-layer-offset detector design for depth-of-interaction capability and higher detection efficiency, but the irregular design caused some difficulties in calculating the normalization factors and the sensitivity map. Besides, the relatively larger (2 mm) crystal cross-section size also posed a challenge to high-resolution image reconstruction. PURPOSE We present an efficient image reconstruction method to achieve high imaging performance for the PET subsystem of Inliview-3000B. METHODS List mode reconstruction with efficient system modeling was used for the PET imaging. We adopt an on-the-fly multi-ray tracing method with random crystal sampling to model the solid angle, crystal penetration and object attenuation effect, and modify the system response model during each iteration to improve the reconstruction performance and computational efficiency. We estimate crystal efficiency with a novel iterative approach that combines measured cylinder phantom data with simulated line-of-response (LOR)-based factors for normalization correction before reconstruction. Since it is necessary to calculate normalization factors and the sensitivity map, we stack the two crystal layers together and extend the conventional data organization method here to index all useful LORs. Simulations and experiments were performed to demonstrate the feasibility and advantage of the proposed method. RESULTS Simulation results showed that the iterative algorithm for crystal efficiency estimation could achieve good accuracy. NEMA image quality phantom studies have demonstrated the superiority of random sampling, which is able to achieve good imaging performance with much less computation than traditional uniform sampling. In the spatial resolution evaluation based on the mini-Derenzo phantom, 1.1 mm hot rods could be identified with the proposed reconstruction method. Reconstruction of double mice and a rat showed good spatial resolution and a high signal-to-noise ratio, and organs with higher uptake could be recognized well. CONCLUSION The results validated the superiority of introducing randomness into reconstruction, and demonstrated its reliability for high-performance imaging. The Inliview-3000B PET subsystem with the proposed image reconstruction can provide rich and detailed information on small animals for preclinical research.
Collapse
Affiliation(s)
- Li Cheng
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
| | - Zhenlei Lyu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
| | - Hui Liu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
| | - Jing Wu
- Center for Advanced Quantum Studies and Department of Physics, Beijing Normal University, Beijing, China
| | - Chao Jia
- Beijing Novel Medical Equipment Ltd, Beijing, China
| | - Yuanguang Wu
- Beijing Novel Medical Equipment Ltd, Beijing, China
| | - Yingcai Ji
- Beijing Novel Medical Equipment Ltd, Beijing, China
| | | | - Tianyu Ma
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
| | - Yaqiang Liu
- Department of Engineering Physics, Tsinghua University, Beijing, China
- Key Laboratory of Particle & Radiation Imaging, Ministry of Education (Tsinghua University), Beijing, China
| |
Collapse
|
6
|
El Ouaridi A, Ait Elcadi Z, Mkimel M, Bougteb M, El Baydaoui R. The detection instrumentation and geometric design of clinical PET scanner: towards better performance and broader clinical applications. Biomed Phys Eng Express 2024; 10:032002. [PMID: 38412520 DOI: 10.1088/2057-1976/ad2d61] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 02/27/2024] [Indexed: 02/29/2024]
Abstract
Positron emission tomography (PET) is a powerful medical imaging modality used in nuclear medicine to diagnose and monitor various clinical diseases in patients. It is more sensitive and produces a highly quantitative mapping of the three-dimensional biodistribution of positron-emitting radiotracers inside the human body. The underlying technology is constantly evolving, and recent advances in detection instrumentation and PET scanner design have significantly improved the medical diagnosis capabilities of this imaging modality, making it more efficient and opening the way to broader, innovative, and promising clinical applications. Some significant achievements related to detection instrumentation include introducing new scintillators and photodetectors as well as developing innovative detector designs and coupling configurations. Other advances in scanner design include moving towards a cylindrical geometry, 3D acquisition mode, and the trend towards a wider axial field of view and a shorter diameter. Further research on PET camera instrumentation and design will be required to advance this technology by improving its performance and extending its clinical applications while optimising radiation dose, image acquisition time, and manufacturing cost. This article comprehensively reviews the various parameters of detection instrumentation and PET system design. Firstly, an overview of the historical innovation of the PET system has been presented, focusing on instrumental technology. Secondly, we have characterised the main performance parameters of current clinical PET and detailed recent instrumental innovations and trends that affect these performances and clinical practice. Finally, prospects for this medical imaging modality are presented and discussed. This overview of the PET system's instrumental parameters enables us to draw solid conclusions on achieving the best possible performance for the different needs of different clinical applications.
Collapse
Affiliation(s)
- Abdallah El Ouaridi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Zakaria Ait Elcadi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
- Electrical and Computer Engineering, Texas A&M University at Qatar, Doha, 23874, Qatar
| | - Mounir Mkimel
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Mustapha Bougteb
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Redouane El Baydaoui
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| |
Collapse
|
7
|
Cao X, Feng N, Huang Q, Liu Y. Nanoscale Metal-Organic Frameworks and Nanoscale Coordination Polymers: From Synthesis to Cancer Therapy and Biomedical Imaging. ACS APPLIED BIO MATERIALS 2024. [PMID: 38382060 DOI: 10.1021/acsabm.3c01300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Recently, there has been significant interest in nanoscale metal-organic frameworks (NMOFs) characterized by ordered crystal structures and nanoscale coordination polymers (NCPs) featuring amorphous structures. These structures arise from the coordination interactions between inorganic metal ions or clusters and organic ligands. Their advantages, such as the ability to tailor composition and structure, efficiently encapsulate diverse therapeutic or imaging agents within porous frameworks, inherent biodegradability, and surface functionalization capability, position them as promising carriers in the biomedical fields. This review provides an overview of the synthesis and surface modification strategies employed for NMOFs and NCPs, along with their applications in cancer treatment and biological imaging. Finally, future directions and challenges associated with the utilization of NMOFs and NCPs in cancer treatment and diagnosis are also discussed.
Collapse
Affiliation(s)
- Xianghui Cao
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Functional Polymer Materials of Ministry of Education, College of Chemistry, Frontiers Science Center for New Organic Matter, Nankai University, Tianjin 300071, China
| | - Nana Feng
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Functional Polymer Materials of Ministry of Education, College of Chemistry, Frontiers Science Center for New Organic Matter, Nankai University, Tianjin 300071, China
| | - Qingqing Huang
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Functional Polymer Materials of Ministry of Education, College of Chemistry, Frontiers Science Center for New Organic Matter, Nankai University, Tianjin 300071, China
| | - Yang Liu
- State Key Laboratory of Medicinal Chemical Biology, Key Laboratory of Functional Polymer Materials of Ministry of Education, College of Chemistry, Frontiers Science Center for New Organic Matter, Nankai University, Tianjin 300071, China
| |
Collapse
|
8
|
Muller FM, Vervenne B, Maebe J, Blankemeyer E, Sellmyer MA, Zhou R, Karp JS, Vanhove C, Vandenberghe S. Image Denoising of Low-Dose PET Mouse Scans with Deep Learning: Validation Study for Preclinical Imaging Applicability. Mol Imaging Biol 2024; 26:101-113. [PMID: 37875748 DOI: 10.1007/s11307-023-01866-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 10/09/2023] [Accepted: 10/12/2023] [Indexed: 10/26/2023]
Abstract
PURPOSE Positron emission tomography (PET) image quality can be improved by higher injected activity and/or longer acquisition time, but both may often not be practical in preclinical imaging. Common preclinical radioactive doses (10 MBq) have been shown to cause deterministic changes in biological pathways. Reducing the injected tracer activity and/or shortening the scan time inevitably results in low-count acquisitions which poses a challenge because of the inherent noise introduction. We present an image-based deep learning (DL) framework for denoising lower count micro-PET images. PROCEDURES For 36 mice, a 15-min [18F]FDG (8.15 ± 1.34 MBq) PET scan was acquired at 40 min post-injection on the Molecubes β-CUBE (in list mode). The 15-min acquisition (high-count) was parsed into smaller time fractions of 7.50, 3.75, 1.50, and 0.75 min to emulate images reconstructed at 50, 25, 10, and 5% of the full counts, respectively. A 2D U-Net was trained with mean-squared-error loss on 28 high-low count image pairs. RESULTS The DL algorithms were visually and quantitatively compared to spatial and edge-preserving denoising filters; the DL-based methods effectively removed image noise and recovered image details much better while keeping quantitative (SUV) accuracy. The largest improvement in image quality was seen in the images reconstructed with 10 and 5% of the counts (equivalent to sub-1 MBq or sub-1 min mouse imaging). The DL-based denoising framework was also successfully applied on the NEMA-NU4 phantom and different tracer studies ([18F]PSMA, [18F]FAPI, and [68 Ga]FAPI). CONCLUSION Visual and quantitative results support the superior performance and robustness in image denoising of the implemented DL models for low statistics micro-PET. This offers much more flexibility in optimizing preclinical, longitudinal imaging protocols with reduced tracer doses or shorter durations.
Collapse
Affiliation(s)
- Florence M Muller
- Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000, Ghent, Belgium.
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA19104, USA.
| | - Boris Vervenne
- Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000, Ghent, Belgium
| | - Jens Maebe
- Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000, Ghent, Belgium
| | - Eric Blankemeyer
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA19104, USA
| | - Mark A Sellmyer
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA19104, USA
| | - Rong Zhou
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA19104, USA
| | - Joel S Karp
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA19104, USA
| | - Christian Vanhove
- Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000, Ghent, Belgium
| | - Stefaan Vandenberghe
- Medical Image and Signal Processing (MEDISIP), Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, 9000, Ghent, Belgium
| |
Collapse
|
9
|
Abstract
Biomedical research has long relied on small-animal studies to elucidate disease process and develop new medical treatments. The introduction of in vivo functional imaging technology, such as PET, has allowed investigators to peer inside their subjects and follow disease progression longitudinally as well as improve understanding of normal biological processes. Recent developments in CRISPR, immuno-PET, and high-resolution in vivo imaging have only increased the importance of small-animal, or preclinical, PET imaging. Other drivers of preclinical PET innovation include new combinations of imaging technologies, such as PET/MR imaging, which require changes to PET hardware.
Collapse
Affiliation(s)
- Adrienne L Lehnert
- Department of Radiology, University of Washington, 1959 Northeast Pacific Street, UW Box 356043, Seattle, WA, USA.
| | - Robert S Miyaoka
- Department of Radiology, University of Washington, 1959 Northeast Pacific Street, UW Box 356043, Seattle, WA, USA
| |
Collapse
|
10
|
Arabi H, Zaidi H. Recent Advances in Positron Emission Tomography/Magnetic Resonance Imaging Technology. Magn Reson Imaging Clin N Am 2023; 31:503-515. [PMID: 37741638 DOI: 10.1016/j.mric.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/25/2023]
Abstract
More than a decade has passed since the clinical deployment of the first commercial whole-body hybrid PET/MR scanner in the clinic. The major advantages and limitations of this technology have been investigated from technical and medical perspectives. Despite the remarkable advantages associated with hybrid PET/MR imaging, such as reduced radiation dose and fully simultaneous functional and structural imaging, this technology faced major challenges in terms of mutual interference between MRI and PET components, in addition to the complexity of achieving quantitative imaging owing to the intricate MRI-guided attenuation correction in PET/MRI. In this review, the latest technical developments in PET/MRI technology as well as the state-of-the-art solutions to the major challenges of quantitative PET/MR imaging are discussed.
Collapse
Affiliation(s)
- Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva 4 CH-1211, Switzerland; Geneva University Neurocenter, Geneva University, Geneva CH-1205, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen 9700 RB, Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense 500, Denmark.
| |
Collapse
|
11
|
Yoshida E, Obata F, Yamaya T. Calibration method of crosshair light sharing PET detector with TOF and DOI capabilities. Biomed Phys Eng Express 2023; 9:055031. [PMID: 37586333 DOI: 10.1088/2057-1976/acf0c7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 08/16/2023] [Indexed: 08/18/2023]
Abstract
Objective. A crosshair light sharing (CLS) PET detector as a TOF-DOI PET detector with high spatial resolution has been developed. To extend that work, a detector calibration method was developed to achieve both higher coincidence resolving time (CRT) and DOI resolution.Approach. The CLS PET detector uses a three-layer reflective material in a two-dimensional crystal array to form a loop structure within a pair of crystals, enabling a CRT of about 300 ps and acquisition of DOI from multi-pixel photon counter (MPPC) output ratios. The crystals were 1.45 × 1.45 × 15 mm3fast LGSO, and the crystal array was optically coupled to an MPPC array. It is important to reduce as many inter-crystal scattering (ICS) events as possible in advance for the accurate detector calibration. DOI information is also expected to improve the CRT because it can estimate the time delay due to the detection depth of crystals.Main results. Using crystal identification and light collection rate of the highest MPPC output reduces the number of ICS events, and CRT is improved by 26%. In addition, CRT is further improved by 13% with a linear correction of time delay as a function of energy. The DOI is ideally estimated from the output ratio of only the MPPC pairs optically coupled to the interacted crystals, which is highly accurate, but the error is large due to light leakage in actual use. The previous method, which also utilizes light leakage to calculate the output ratio, is less accurate, but the error can be reduced. Using the average of the two methods, it is possible to improve the DOI resolution by 12% while maintaining the smaller error.Significance. By applying the developed calibration method, the CLS PET detector achieves the CRT of 251 ps and the DOI resolution of 3.3 mm.
Collapse
Affiliation(s)
- Eiji Yoshida
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| | - Fujino Obata
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| | - Taiga Yamaya
- National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
| |
Collapse
|
12
|
Liu Z, Mungai S, Niu M, Kuang Z, Ren N, Wang X, Sang Z, Yang Y. Edge effect reduction of high-resolution PET detectors using LYSO and GAGG phoswich crystals. Phys Med Biol 2023; 68. [PMID: 36808920 DOI: 10.1088/1361-6560/acbde1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Accepted: 02/21/2023] [Indexed: 02/23/2023]
Abstract
Objective. Small-animal positron emission tomography (PET) is a powerful preclinical imaging tool in animal model studies. The spatial resolution and sensitivity of current PET scanners developed for small-animal imaging need to be improved to increase the quantitative accuracy of preclinical animal studies. This study aimed to improve the identification capability of edge scintillator crystals of a PET detector which will enable to apply a crystal array with the same cross-section area as the active area of a photodetector for improving the detection area and thus reducing or eliminating the inter-detector gaps.Approach. PET detectors using crystal arrays with mixed lutetium yttrium orthosilicate (LYSO) and gadolinium aluminum gallium garnet (GAGG) crystals were developed and evaluated. The crystal arrays consisted of 31 × 31 array of 0.49 × 0.49 × 20 mm3crystals; they were read out by two silicon photomultiplier arrays with pixel sizes of 2 × 2 mm2that were placed at both ends of the crystal arrays. The second or first outermost layer of the LYSO crystals was replaced by GAGG crystals in the two crystal arrays. The two crystal types were identified using a pulse-shape discrimination technique to provide better edge crystal identification.Main results. Using the pulse shape discrimination technique, almost all (except for a few edge) crystals were resolved in the two detectors; high sensitivity was achieved by using the scintillator array and the photodetector with the same areas and achieved high resolution by using crystals with sizes equal to 0.49 × 0.49 × 20 mm3. Energy resolutions of 19.3 ± 1.8% and 18.9 ± 1.5%, depth-of-interaction resolutions of 2.02 ± 0.17 mm and 2.04 ± 0.18 mm, and timing resolutions of 1.6 ± 0.2 ns and 1.5 ± 0.2 ns were achieved by the two detectors, respectively.Significance. In summary, novel three-dimensional high-resolution PET detectors consisting of a mixture of LYSO and GAGG crystals were developed. The detectors significantly improve the detection area with the same photodetectors and thus improve the detection efficiency.
Collapse
Affiliation(s)
- Zheng Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Samuel Mungai
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Ming Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Zhonghua Kuang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Ning Ren
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Xiaohui Wang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Ziru Sang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Yongfeng Yang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| |
Collapse
|
13
|
Seo M, Ko GB, Kim KY, Son JW, Byun JW, Lee YS, Kim KM, Park JW, Kim K, Lee T, Lee JS. Performance evaluation of SimPET-L and SimPET-XL: MRI-compatible small-animal PET systems with rat-body imaging capability. EJNMMI Phys 2023; 10:16. [PMID: 36881339 PMCID: PMC9992463 DOI: 10.1186/s40658-023-00534-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 02/10/2023] [Indexed: 03/08/2023] Open
Abstract
BACKGROUND SimPET-L and SimPET-XL have recently been introduced with increased transaxial fields of view (FOV) compared with their predecessors (SimPET™ and SimPET-X), enabling whole-body positron emission tomography (PET) imaging of rats. We conducted performance evaluations of SimPET-L and SimPET-XL and rat-body imaging with SimPET-XL to demonstrate the benefits of increased axial and transaxial FOVs. PROCEDURES The detector blocks in SimPET-L and SimPET-XL consist of two 4 × 4 silicon photomultiplier arrays coupled with 20 × 9 array lutetium oxyorthosilicate crystals. SimPET-L and SimPET-XL have an inner diameter (bore size) of 7.6 cm, and they are composed of 40 and 80 detector blocks yielding axial lengths of 5.5 and 11 cm, respectively. Each system was evaluated according to the National Electrical Manufacturers Association NU4-2008 protocol. Rat imaging studies, such as 18F-NaF and 18F-FDG PET, were performed using SimPET-XL. RESULTS The radial resolutions at the axial center measured using the filtered back projection, 3D ordered-subset expectation maximization (OSEM), and 3D OSEM with point spread functions correction were 1.7, 0.82, and 0.82 mm FWHM in SimPET-L and 1.7, 0.91, and 0.91 mm FWHM in SimPET-XL, respectively. The peak sensitivities of SimPET-L and SimPET-XL were 6.30% and 10.4% for an energy window of 100-900 keV and 4.44% and 7.25% for a window of 250-750 keV, respectively. The peak noise equivalent count rate with an energy window of 250-750 keV was 249 kcps at 44.9 MBq for SimPET-L and 349 kcps at 31.3 MBq for SimPET-XL. In SimPET-L, the uniformity was 4.43%, and the spill-over ratios in air- and water-filled chambers were 5.54% and 4.10%, respectively. In SimPET-XL, the uniformity was 3.89%, and the spill-over ratio in the air- and water-filled chambers were 3.56% and 3.60%. Moreover, SimPET-XL provided high-quality images of rats. CONCLUSION SimPET-L and SimPET-XL show adequate performance compared with other SimPET systems. In addition, their large transaxial and long axial FOVs provide imaging capability for rats with high image quality.
Collapse
Affiliation(s)
- Minjee Seo
- Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, 03080, South Korea.,Department of Nuclear Medicine, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea
| | - Guen Bae Ko
- Brightonix Imaging Inc., Seoul, 04782, South Korea
| | | | | | - Jung Woo Byun
- Department of Nuclear Medicine, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea
| | - Yun-Sang Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea
| | - Kyeong Min Kim
- Korea Institute of Radiological and Medical Sciences, Seoul, 01812, South Korea
| | - Jang Woo Park
- Korea Institute of Radiological and Medical Sciences, Seoul, 01812, South Korea
| | - Kipom Kim
- Brain Research Core Facility, Korea Brain Research Institute, 61 Cheomdan-ro, Dong-gu, Daegu, 41062, South Korea
| | - Taekwan Lee
- Brain Research Core Facility, Korea Brain Research Institute, 61 Cheomdan-ro, Dong-gu, Daegu, 41062, South Korea.
| | - Jae Sung Lee
- Department of Biomedical Sciences, Seoul National University College of Medicine, Seoul, 03080, South Korea. .,Department of Nuclear Medicine, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea. .,Brain Research Core Facility, Korea Brain Research Institute, 61 Cheomdan-ro, Dong-gu, Daegu, 41062, South Korea.
| |
Collapse
|
14
|
Zatcepin A, Ziegler SI. Detectors in positron emission tomography. Z Med Phys 2023; 33:4-12. [PMID: 36208967 PMCID: PMC10082375 DOI: 10.1016/j.zemedi.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 08/25/2022] [Indexed: 11/05/2022]
Abstract
Positron emission tomography is a highly sensitive molecular imaging modality, based on the coincident detection of annihilation photons after positron decay. The most used detector is based on dense, fast, and luminous scintillators read out by light sensors. This review covers the various detector concepts for clinical and preclinical systems.
Collapse
Affiliation(s)
- Artem Zatcepin
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany
| | - Sibylle I Ziegler
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
15
|
Du J, Jones T. Technical opportunities and challenges in developing total-body PET scanners for mice and rats. EJNMMI Phys 2023; 10:2. [PMID: 36592266 PMCID: PMC9807733 DOI: 10.1186/s40658-022-00523-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 12/20/2022] [Indexed: 01/03/2023] Open
Abstract
Positron emission tomography (PET) is the most sensitive in vivo molecular imaging technique available. Small animal PET has been widely used in studying pharmaceutical biodistribution and disease progression over time by imaging a wide range of biological processes. However, it remains true that almost all small animal PET studies using mouse or rat as preclinical models are either limited by the spatial resolution or the sensitivity (especially for dynamic studies), or both, reducing the quantitative accuracy and quantitative precision of the results. Total-body small animal PET scanners, which have axial lengths longer than the nose-to-anus length of the mouse/rat and can provide high sensitivity across the entire body of mouse/rat, can realize new opportunities for small animal PET. This article aims to discuss the technical opportunities and challenges in developing total-body small animal PET scanners for mice and rats.
Collapse
Affiliation(s)
- Junwei Du
- grid.27860.3b0000 0004 1936 9684Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA
| | - Terry Jones
- grid.27860.3b0000 0004 1936 9684Department of Radiology, University of California at Davis, Davis, CA 95616 USA
| |
Collapse
|
16
|
Hunter W, Dolinsky S, Kinahan P, Miyaoka R. Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023; 7:1-10. [PMID: 36644761 PMCID: PMC9835997 DOI: 10.1109/trpms.2022.3187955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
We evaluated the 3D spatial, energy, and timing resolution of the Brain (or Breast)-Initiative Next-Generation (BING) PET detector. The BING detector is an array of 1-mm-thick slats of LYSO scintillator with lapped specular-reflective faces (15-mm by 52-mm) that are stacked together and oriented with their long-narrow edges normal to the imaging field of view. Interaction positions are determined from the signals of silicon-photomultiplier (SiPM) arrays placed on the entrance (top) and exit (bottom) faces. The SiPM arrays are offset to determine the slat of interaction (SOI) without requiring any optical light sharing between slats. Maximum likelihood 2D location within the SOI is determined using the sensor signals. Interaction time is determined with a modified first-optical-photon pickoff method. Performance of the BING detector was measured as a function of position using a sideways coincidence-collimated beam. Slats were accurately identified, with an effective tangential detector resolution of 1 mm. Average resolutions (and ranges) are: 0.96 mm (0.85 mm to 1.11 mm) for lateral (axial) detector resolution, 1.6 mm (1.0 mm to 2.1 mm) for depth resolution, 13.6% (12.7% to 16.0%) for energy resolution, and 317 ps (241 ps to 404 ps) for coincidence timing resolution. Initial spatial and timing resolution results demonstrated that the BING detector can be effective in a small field-of view (e.g., brain or breast) PET system.
Collapse
Affiliation(s)
- William Hunter
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| | - Sergei Dolinsky
- Sergei Dolinsky is with GE Research, Semiconductors, Niskayuna, NY, 12309, USA
| | - Paul Kinahan
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| | - Robert Miyaoka
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| |
Collapse
|
17
|
Freire M, Gonzalez-Montoro A, Cañizares G, Rezaei A, Nuyts J, Berr SS, Williams MB, Benlloch JM, Gonzalez AJ. Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:697-706. [PMID: 35909498 PMCID: PMC9328404 DOI: 10.1109/trpms.2021.3124448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
Improving sensitivity and spatial resolution in small animal Positron Emission Tomography imaging instrumentation constitutes one of the main goals of nuclear imaging research. These parameters are degraded by the presence of gaps between the detectors. The present manuscript experimentally validates our prototype of an edge-less pre-clinical PET system based on a single LYSO:Ce annulus with an inner diameter of 62 mm and 10 outer facets of 26 × 52 mm2. Scintillation light is read out by arrays of 8 × 8 SiPMs coupled to the facets, using a projection readout of the rows and columns signals. The readout provides accurate Depth of Interaction (DOI). We have implemented a calibration that mitigates the DOI-dependency of the transaxial and axial impact coordinates, and the energy photopeak gain. An energy resolution of 23.4 ± 1.8% was determined. Average spatial resolution of 1.4 ± 0.2 and 1.3 ± 0.4 mm FWHM were achieved for the radial and axial directions, respectively. We found a peak sensitivity of 3.8% at the system center, and a maximum NECR at 40.6 kcps for 0.27 mCi. The image quality was evaluated using reconstructed images of an array of sources and the NEMA image quality phantom was also studied.
Collapse
Affiliation(s)
- Marta Freire
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | | | - Gabriel Cañizares
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | - Ahmadreza Rezaei
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Leuven, Belgium
| | - Johan Nuyts
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Leuven, Belgium
| | - Stuart S Berr
- Department of Radiology and Medical Imaging, The University of Virginia, Charlottesville, Virginia, United States
| | - Mark B Williams
- Department of Radiology and Medical Imaging, The University of Virginia, Charlottesville, Virginia, United States
| | - Jose M Benlloch
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | - Antonio J Gonzalez
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| |
Collapse
|
18
|
Cong L, Kuang Z, Sang Z, Wang X, Niu M, Yang Y. Comparison of arithmetic mean and energy-weighted mean flood histogram generation methods for dual-ended readout PET detectors. Med Phys 2022; 49:4455-4465. [PMID: 35567406 DOI: 10.1002/mp.15710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2021] [Revised: 04/26/2022] [Accepted: 05/03/2022] [Indexed: 11/05/2022] Open
Abstract
PURPOSE Dual-ended readout pixelated scintillator array detectors can provide a suitable crystal resolvability and satisfactory depth of interaction (DOI), energy, and timing resolutions. Usually, the flood histogram measured by one-sided readout is depth dependent, and the flood histogram quality degrades as the distance between the interaction site and photodetector increases. Information measured by two photodetectors must be combined to obtain an improved flood histogram yielding a better PET scanner spatial resolution. METHODS Two flood histogram generation algorithms for dual-ended readout of pixelated scintillator array detectors were compared by theoretical calculations and experimental measurements. The first algorithm is the arithmetic mean (AM) algorithm, which assigns the same weight to the flood histograms measured by photodetectors 1 and 2. The second algorithm is the energy-weighted mean (EWM) algorithm, which assigns each flood histogram a certain weight proportional to the energy measured by the photodetector. Theoretical equations were derived to determine the quality of the flood histograms obtained with these two algorithms. Experimental measurements were performed with an 18 × 18 lutetium-yttrium oxyorthosilicate (LYSO) array with a crystal size of 0.62 × 0.62 × 20 mm3 read out by two multi-anode photomultiplier tubes at both ends. Flood histograms of the whole array and five specific depths were compared between the above two algorithms. RESULTS The theoretical results indicated that the flood histograms obtained with the EWM method matched those obtained with the AM method at the middle detector depth and were better at other detector depths when the distance (S) between the locations of the same crystal in the flood histograms measured by photodetectors 1 and 2 reached 0. The advantage of the EWM method decreased with increasing S value since the crystal position in the flood histogram obtained with the EWM method varies with the depth when S does not equal 0. The advantage of the EWM method decreased with increasing S value. The experimental results generally agreed with the theoretical predictions. Compared to the AM method, the EWM method provided a similar flood histogram at a depth of 10 mm but generated a better flood histogram at depths of 2 and 18 mm. Although an inverse correlation between Q (a quality factor representing the advantage of the EWM method) and S was observed, the variation in Q given the same S value was high. The average Q value at the same S still agreed with the theoretical predictions. CONCLUSIONS Theoretical equations were derived, and experimental measurements were performed to compare two flood histogram generation algorithms for dual-ended readout PET detectors. The results indicated that the EWM method based on inverse variance weighting theory could provide better flood histograms than those provided by the AM method. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Longhan Cong
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Zhonghua Kuang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Ziru Sang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Xiaohui Wang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Ming Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| | - Yongfeng Yang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, People's Republic of China
| |
Collapse
|
19
|
Adler SS, Seidel J, Choyke PL. Advances in Preclinical PET. Semin Nucl Med 2022; 52:382-402. [PMID: 35307164 PMCID: PMC9038721 DOI: 10.1053/j.semnuclmed.2022.02.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 02/11/2022] [Accepted: 02/14/2022] [Indexed: 12/18/2022]
Abstract
The classical intent of PET imaging is to obtain the most accurate estimate of the amount of positron-emitting radiotracer in the smallest possible volume element located anywhere in the imaging subject at any time using the least amount of radioactivity. Reaching this goal, however, is confounded by an enormous array of interlinked technical issues that limit imaging system performance. As a result, advances in PET, human or animal, are the result of cumulative innovations across each of the component elements of PET, from data acquisition to image analysis. In the report that follows, we trace several of these advances across the imaging process with a focus on small animal PET.
Collapse
Affiliation(s)
- Stephen S Adler
- Frederick National Laboratory for Cancer Research, Frederick, MD; Molecular Imaging Branch, National Cancer Institute, Bethesda MD
| | - Jurgen Seidel
- Contractor to Frederick National Laboratory for Cancer Research, Leidos biodical Research, Inc., Frederick, MD; Molecular Imaging Branch, National Cancer Institute, Bethesda MD
| | - Peter L Choyke
- Molecular Imaging Branch, National Cancer Institute, Bethesda MD.
| |
Collapse
|
20
|
Du J. Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSO₄ Reflector. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:522-528. [PMID: 36212107 PMCID: PMC9540608 DOI: 10.1109/trpms.2021.3096534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this paper, the performance of two dual-ended readout PET detectors based on 15 × 15 BGO arrays were compared. The crystal elements of one BGO array have polished lateral surfaces, while the crystal elements of the other BGO array have unpolished lateral surfaces. The two ends of the BGO elements are polished. The two BGO arrays both have a pitch size of 1.6 mm and thickness of 20 mm, and BaSO4 with a thickness of 80 μm was used as the reflector. Hamamatsu S14161-0305-08 SiPM arrays were used as photodetectors. All the measurements were performed at a bias voltage of 41.0 V and a temperature of 23.5 °C. The flood histograms show that all the crystal elements in the two BGO arrays were clearly resolved. The detector based on the BGO array with polished lateral surfaces provides an energy resolution of 16.9 ± 1.3%, timing resolution of 3.2 ± 0.2 ns, and DOI resolution of 18.4 ± 2.2 mm. In comparison, the detector based on the BGO array with unpolished lateral surfaces provides an energy resolution of 17.7 ± 2.0%, timing resolution of 3.5 ± 0.3 ns, and DOI resolution of 3.2 ± 0.2 mm.
Collapse
Affiliation(s)
- Junwei Du
- Department of Biomedical Engineering, University of California at Davis, Davis, CA, USA
| |
Collapse
|
21
|
Yitbarek D, Dagnaw GG. Application of Advanced Imaging Modalities in Veterinary Medicine: A Review. Vet Med (Auckl) 2022; 13:117-130. [PMID: 35669942 PMCID: PMC9166686 DOI: 10.2147/vmrr.s367040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/26/2022] [Indexed: 11/28/2022]
Abstract
Veterinary anatomy has traditionally relied on detailed dissections to produce anatomical illustrations, but modern imaging modalities, now represent an enormous resource that allows for fast non-invasive visualizations in living animals for clinical and research purposes. In this review, advanced anatomical imaging modalities and their applications, safety issues, challenges, and future prospects of the techniques commonly employed for animal imaging would be highlighted. The quality of diagnostic imaging equipment in veterinary practice has greatly improved. Recent advances made in veterinary advanced imaging specifically about cross-sectional modalities (CT and MRI), nuclear medicine (PET, SPECT), and dual imaging modalities (PET/CT, PET/MR, and SPECT/CT) have become widely available, leading to greater demands and expectations from veterinary clients. These modalities allow for the creation of three-dimensional representations that can be of considerable value in the dissemination of clinical diagnosis and anatomical studies. Despite, the modern imaging modalities well established in developed countries across the globe, it is yet to remain in its infancy stage in veterinary practice in developing countries due to heavy initial investment and maintenance costs, lack of expert interpretation, a requirement of specialized technical staff and need of adjustable machines to accommodate the different range of animal sizes. Therefore, veterinarians should take advantage of these imaging techniques in designing future experiments by considering the availability of these varied imaging modalities and the creation of three-dimensional graphical representations of internal structures.
Collapse
Affiliation(s)
| | - Gashaw Getaneh Dagnaw
- Department of Biomedical Sciences, College of Veterinary Medicine and Animal Sciences, University of Gondar, Gondar, Ethiopia
- Correspondence: Gashaw Getaneh Dagnaw, Department of Biomedical Sciences, College of Veterinary Medicine and Animal Sciences, University of Gondar, P.O. Box: 196, Gondar, Ethiopia, Email
| |
Collapse
|
22
|
Ren W, Ji B, Guan Y, Cao L, Ni R. Recent Technical Advances in Accelerating the Clinical Translation of Small Animal Brain Imaging: Hybrid Imaging, Deep Learning, and Transcriptomics. Front Med (Lausanne) 2022; 9:771982. [PMID: 35402436 PMCID: PMC8987112 DOI: 10.3389/fmed.2022.771982] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 02/16/2022] [Indexed: 12/26/2022] Open
Abstract
Small animal models play a fundamental role in brain research by deepening the understanding of the physiological functions and mechanisms underlying brain disorders and are thus essential in the development of therapeutic and diagnostic imaging tracers targeting the central nervous system. Advances in structural, functional, and molecular imaging using MRI, PET, fluorescence imaging, and optoacoustic imaging have enabled the interrogation of the rodent brain across a large temporal and spatial resolution scale in a non-invasively manner. However, there are still several major gaps in translating from preclinical brain imaging to the clinical setting. The hindering factors include the following: (1) intrinsic differences between biological species regarding brain size, cell type, protein expression level, and metabolism level and (2) imaging technical barriers regarding the interpretation of image contrast and limited spatiotemporal resolution. To mitigate these factors, single-cell transcriptomics and measures to identify the cellular source of PET tracers have been developed. Meanwhile, hybrid imaging techniques that provide highly complementary anatomical and molecular information are emerging. Furthermore, deep learning-based image analysis has been developed to enhance the quantification and optimization of the imaging protocol. In this mini-review, we summarize the recent developments in small animal neuroimaging toward improved translational power, with a focus on technical improvement including hybrid imaging, data processing, transcriptomics, awake animal imaging, and on-chip pharmacokinetics. We also discuss outstanding challenges in standardization and considerations toward increasing translational power and propose future outlooks.
Collapse
Affiliation(s)
- Wuwei Ren
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
- Shanghai Engineering Research Center of Energy Efficient and Custom AI IC, Shanghai, China
| | - Bin Ji
- Department of Radiopharmacy and Molecular Imaging, School of Pharmacy, Fudan University, Shanghai, China
| | - Yihui Guan
- PET Center, Huashan Hospital, Fudan University, Shanghai, China
| | - Lei Cao
- Shanghai Changes Tech, Ltd., Shanghai, China
| | - Ruiqing Ni
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
- Institute for Biomedical Engineering, ETH Zürich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
23
|
Niu M, Liu Z, Kuang Z, Wang X, Ren N, Sang Z, Wu S, Cong L, Sun T, Hu Z, Yang Y. Ultra-high resolution depth-encoding small animal PET detectors: Using GAGG and LYSO crystal arrays. Med Phys 2022; 49:3006-3020. [PMID: 35301730 DOI: 10.1002/mp.15606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 03/03/2022] [Accepted: 03/03/2022] [Indexed: 11/12/2022] Open
Abstract
PURPOSE Small animal PET scanners are widely used in current biomedical research. The study aimed to develop high efficiency and ultra-high resolution detectors that could be used to develop a small animal PET scanner with high sensitivity and spatial resolution approaching to its physical limit. METHODS 4 crystal arrays were fabricated and measured in this study. Crystal arrays 1 and 2 consisted of 38 × 38 GAGG and LYSO crystals of 0.4 × 0.4 × 20 mm3 size. Crystal array 3 consisted of 16 × 16 GAGG crystals of 0.3 × 0.3 × 20 mm3 size, and crystal array 4 consisted of 24 × 24 LYSO crystals 0.3 × 0.3 × 20 mm3 in size. The crystal arrays were dual-ended readouts using 8 × 8 SiPM arrays of 2 × 2 mm2 pixel area. The SiPM array was read-out using a signal multiplexing circuit to convert the 64 output signals into 4 position-encoding signals. The performances of the 4 detectors in terms of flood histogram, energy resolution, depth of interaction resolution and timing resolution were measured. RESULTS The GAGG detectors provided better flood histograms, ∼30% higher photopeak amplitude, ∼20% higher energy resolution, ∼12% worse DOI resolution and ∼15% worse timing resolution compared with LYSO detectors of the same crystal size. These 4 detectors provided DOI resolutions of <2 mm, energy resolutions of <22% and timing resolutions of <1.6 ns. All crystals of 0.4 × 0.4 × 20 mm3 and 0.3 × 0.3 × 20 mm3 could be clearly resolved if the crystal array was 1 mm smaller in the four sides than that in the SiPM array. CONCLUSIONS High DOI resolution PET detectors were developed using both GAGG and LYSO arrays with crystal sizes of 0.3 and 0.4 mm, respectively, and a length of 20 mm. The detectors can be used in the future to develop small animal PET scanners, especially dedicated mouse imaging PET scanners, which can simultaneously achieve high sensitivity and ultra-high spatial resolution. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Ming Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Zheng Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Zhonghua Kuang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Xiaohui Wang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Ning Ren
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Ziru Sang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - San Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Longhan Cong
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Tao Sun
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Zhanli Hu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| | - Yongfeng Yang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China
| |
Collapse
|
24
|
Ni R. Magnetic Resonance Imaging in Tauopathy Animal Models. Front Aging Neurosci 2022; 13:791679. [PMID: 35145392 PMCID: PMC8821905 DOI: 10.3389/fnagi.2021.791679] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 12/27/2021] [Indexed: 11/13/2022] Open
Abstract
The microtubule-associated protein tau plays an important role in tauopathic diseases such as Alzheimer's disease and primary tauopathies such as progressive supranuclear palsy and corticobasal degeneration. Tauopathy animal models, such as transgenic, knock-in mouse and rat models, recapitulating tauopathy have facilitated the understanding of disease mechanisms. Aberrant accumulation of hyperphosphorylated tau contributes to synaptic deficits, neuroinflammation, and neurodegeneration, leading to cognitive impairment in animal models. Recent advances in molecular imaging using positron emission tomography (PET) and magnetic resonance imaging (MRI) have provided valuable insights into the time course of disease pathophysiology in tauopathy animal models. High-field MRI has been applied for in vivo imaging in animal models of tauopathy, including diffusion tensor imaging for white matter integrity, arterial spin labeling for cerebral blood flow, resting-state functional MRI for functional connectivity, volumetric MRI for neurodegeneration, and MR spectroscopy. In addition, MR contrast agents for non-invasive imaging of tau have been developed recently. Many preclinical MRI indicators offer excellent translational value and provide a blueprint for clinical MRI in the brains of patients with tauopathies. In this review, we summarized the recent advances in using MRI to visualize the pathophysiology of tauopathy in small animals. We discussed the outstanding challenges in brain imaging using MRI in small animals and propose a future outlook for visualizing tau-related alterations in the brains of animal models.
Collapse
Affiliation(s)
- Ruiqing Ni
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
25
|
Kang HG, Tashima H, Nishikido F, Akamatsu G, Wakizaka H, Higuchi M, Yamaya T. Initial results of a mouse brain PET insert with a staggered 3-layer DOI detector. Phys Med Biol 2021; 66. [PMID: 34666328 DOI: 10.1088/1361-6560/ac311c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Accepted: 10/19/2021] [Indexed: 11/11/2022]
Abstract
Objective.Small animal positron emission tomography (PET) requires a submillimeter resolution for better quantification of radiopharmaceuticals. On the other hand, depth-of-interaction (DOI) information is essential to preserve the spatial resolution while maintaining the sensitivity. Recently, we developed a staggered 3-layer DOI detector with 1 mm crystal pitch and 15 mm total crystal thickness, but we did not demonstrate the imaging performance of the DOI detector with full ring geometry. In this study we present initial imaging results obtained for a mouse brain PET prototype developed with the staggered 3-layer DOI detector.Approach.The prototype had 53 mm inner diameter and 11 mm axial field-of-view. The PET scanner consisted of 16 DOI detectors each of which had a staggered 3-layer LYSO crystal array (4/4/7 mm) coupled to a 4 × 4 silicon photomultiplier array. The physical performance was evaluated in terms of the NEMA NU 4 2008 protocol.Main Results.The measured spatial resolutions at the center and 15 mm radial offset were 0.67 mm and 1.56 mm for filtered-back-projection, respectively. The peak absolute sensitivity of 0.74% was obtained with an energy window of 400-600 keV. The resolution phantom imaging results show the clear identification of a submillimetric rod pattern with the ordered-subset expectation maximization algorithm. The inter-crystal scatter rejection using a narrow energy window could enhance the resolvability of a 0.75 mm rod significantly.Significance.In an animal imaging experiment, the detailed mouse brain structures such as cortex and thalamus were clearly identified with high contrast. In conclusion, we successfully developed the mouse brain PET insert prototype with a staggered 3-layer DOI detector.
Collapse
Affiliation(s)
- Han Gyu Kang
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Hideaki Tashima
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Fumihiko Nishikido
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Go Akamatsu
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Hidekazu Wakizaka
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Makoto Higuchi
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| | - Taiga Yamaya
- National Institutes for Quantum Science and Technology (QST), 4-9-1, Anagawa, Inage-ku, Chiba, Japan
| |
Collapse
|
26
|
Bebié P, Becker R, Commichau V, Debus J, Dissertori G, Djambazov L, Eleftheriou A, Fischer J, Fischer P, Ito M, Khateri P, Lustermann W, Ritzer C, Ritzert M, Röser U, Tsoumpas C, Warnock G, Weber B, Wyss MT, Zagozdzinska-Bochenek A. SAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI. SENSORS (BASEL, SWITZERLAND) 2021; 21:7037. [PMID: 34770344 PMCID: PMC8588038 DOI: 10.3390/s21217037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 10/15/2021] [Accepted: 10/19/2021] [Indexed: 11/16/2022]
Abstract
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of 54.2mm and an inner diameter of 114mm. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system's Coincidence Resolving Time (CRT) and energy resolution are between separate-uncertainty 209.0(3)ps and separate-uncertainty 12.41(02) Full Width at Half Maximum (FWHM) at low activity and separate-uncertainty 326.89(12)ps and separate-uncertainty 20.630(011) FWHM at 550MBq, respectively. The peak sensitivity is ∼1.6. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300MBq. Based on features visible in the acquired images, we estimate the spatial resolution to be ∼2mm in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500MBq.
Collapse
Affiliation(s)
- Pascal Bebié
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Robert Becker
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Volker Commichau
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Jan Debus
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Günther Dissertori
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Lubomir Djambazov
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Afroditi Eleftheriou
- Institute of Pharmacology and Toxicology, University of Zürich, 8057 Zürich, Switzerland; (A.E.); (G.W.); (B.W.); (M.T.W.)
| | - Jannis Fischer
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Peter Fischer
- Institute of Computer Engineering, Heidelberg University, 69120 Heidelberg, Germany; (P.F.); (M.R.)
| | - Mikiko Ito
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Parisa Khateri
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Werner Lustermann
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Christian Ritzer
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Michael Ritzert
- Institute of Computer Engineering, Heidelberg University, 69120 Heidelberg, Germany; (P.F.); (M.R.)
| | - Ulf Röser
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| | - Charalampos Tsoumpas
- Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds LS2 9JT, UK;
| | - Geoffrey Warnock
- Institute of Pharmacology and Toxicology, University of Zürich, 8057 Zürich, Switzerland; (A.E.); (G.W.); (B.W.); (M.T.W.)
| | - Bruno Weber
- Institute of Pharmacology and Toxicology, University of Zürich, 8057 Zürich, Switzerland; (A.E.); (G.W.); (B.W.); (M.T.W.)
| | - Matthias T. Wyss
- Institute of Pharmacology and Toxicology, University of Zürich, 8057 Zürich, Switzerland; (A.E.); (G.W.); (B.W.); (M.T.W.)
| | - Agnieszka Zagozdzinska-Bochenek
- Institute for Particle Physics and Astrophysics, ETH Zürich, 8093 Zürich, Switzerland; (R.B.); (V.C.); (J.D.); (G.D.); (L.D.); (J.F.); (M.I.); (P.K.); (W.L.); (C.R.); (U.R.); (A.Z.-B.)
| |
Collapse
|
27
|
Cheng X, Hu K, Yang D, Shao Y. A compact and lightweight small animal PET with uniform high-resolution for onboard PET/CT image-guided preclinical radiation oncology research. Phys Med Biol 2021; 66. [PMID: 34592731 DOI: 10.1088/1361-6560/ac2bb4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 09/30/2021] [Indexed: 11/12/2022]
Abstract
OBJECTIVE In contrast to clinical radiation therapy (RT) that ubiquitously uses PET/CT image to accurately guide RT, all current commercial animal irradiators can only provide CT image-guided preclinical RT that severely limits their capability for preclinical and compatibility for translational radiation oncology research. To address this problem, we have developed a compact and lightweight PET with uniform, high spatial resolution that is suited to be installed inside an existing animal irradiator for potential onboard PET/CT image-guided preclinical RT research. APPROACH The design focused on the balance of achieving sufficient imaging performance for practical preclinical RT guidance with constrained size and weight. The detector head consists of a ring of 12 detector panels in a dodecagon configuration and 12 front-end electronics boards that are closely attached to the detector panels. The overall size and weight of the detector head are 33.0 cm diameter, 11.0 cm axial length and ∼6.5 kg weight that can be installed inside an existing irradiator. Each detector panel has a 30 × 30 array of 1 × 1 × 20 mm3LYSO scintillators with depth-of-interaction (DOI) measurement. The front-end electronics boards process and convert detected signals to digital signals and transfer them to system electronics and data acquisition located outside the irradiator through low-voltage-differential-signaling cables. MAIN RESULTS The typical energy, DOI and coincidence timing resolutions are around 22.1%, 3.1 mm, and 1.92 ns. The imaging field-of-view (FOV) is 8.0 cm diameter and 3.5 cm axial length. The performance evaluations show a 1.8% sensitivity at the center FOV, uniform ∼1.1 mm resolution within 6 cm diameter FOV, and all rods of 1.0 mm diameter can be clearly resolved from the image of an ultra-micro hot-rods phantom. SIGNIFICANCE Overall, this compact and lightweight PET has demonstrated its designed capability and performance sufficient for providing onboard functional/biological/molecular image to guide the preclinical RT research.
Collapse
Affiliation(s)
- Xinyi Cheng
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75057, United States of America
| | - Kun Hu
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75057, United States of America
| | - Dongxu Yang
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75057, United States of America
| | - Yiping Shao
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75057, United States of America
| |
Collapse
|
28
|
Zhang X, Yu H, Xie Q, Xie S, Ye B, Guo M, Zhao Z, Huang Q, Xu J, Peng Q. Design study of a PET detector with 0.5 mm crystal pitch for high-resolution preclinical imaging. Phys Med Biol 2021; 66. [PMID: 34130263 DOI: 10.1088/1361-6560/ac0b82] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 06/15/2021] [Indexed: 11/12/2022]
Abstract
Preclinical positron emission tomography (PET) is a sensitive and quantitative molecule imaging modality widely used in characterizing the biological processes and diseases in small animals. The purpose of this study is to investigate the methods to optimize a PET detector for high-resolution preclinical imaging. The PET detector proposed in this study consists of a 28 × 28 array of LYSO crystals 0.5 × 0.5 × 6.25 mm3in size, a wedged lightguide, and a 6 × 6 array of SiPMs 3 × 3 mm2in size. The simulation results showed that the most uniform flood map was achieved when the thickness of the lightguide was 2.35 mm. The quality of the flood map was significantly improved by suppressing the electronics noises using the simple threshold method with a best threshold. The peak-to-valley ratio of flood map improved 25.4% when the algorithm of ICS rejection was applied. An energy resolution (12.96% ± 1.03%) was measured on the prototype scanner constructed with 12 proposed detectors. Lastly, a prototype preclinic PET imager was constructed with 12 optimized detectors. The point source experiment was performed and an excellent spatial resolution (axial: 0.56 mm, tangential: 0.46 mm, radial: 0.42 mm) was achieved with the proposed high-performance PET detectors.
Collapse
Affiliation(s)
- Xi Zhang
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 430074, Wuhan, People's Republic of China
| | - Hongsen Yu
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 430074, Wuhan, People's Republic of China
| | - Qiangqiang Xie
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 430074, Wuhan, People's Republic of China
| | - Siwei Xie
- Institute of Biomedical Engineering Shenzhen Bay Laboratory, Shenzhen, 518132, People's Republic of China
| | - Baihezi Ye
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 430074, Wuhan, People's Republic of China
| | - Minghao Guo
- School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, 200240, Shanghai, People's Republic of China
| | - Zhixiang Zhao
- School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, 200240, Shanghai, People's Republic of China
| | - Qiu Huang
- School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, 200240, Shanghai, People's Republic of China
| | - Jianfeng Xu
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, 430074, Wuhan, People's Republic of China
| | - Qiyu Peng
- Institute of Biomedical Engineering Shenzhen Bay Laboratory, Shenzhen, 518132, People's Republic of China
| |
Collapse
|
29
|
Huang Q, Garrett A, Bose S, Blocker S, Rios AC, Clevers H, Shen X. The frontier of live tissue imaging across space and time. Cell Stem Cell 2021; 28:603-622. [PMID: 33798422 PMCID: PMC8034393 DOI: 10.1016/j.stem.2021.02.010] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
What you see is what you get-imaging techniques have long been essential for visualization and understanding of tissue development, homeostasis, and regeneration, which are driven by stem cell self-renewal and differentiation. Advances in molecular and tissue modeling techniques in the last decade are providing new imaging modalities to explore tissue heterogeneity and plasticity. Here we describe current state-of-the-art imaging modalities for tissue research at multiple scales, with a focus on explaining key tradeoffs such as spatial resolution, penetration depth, capture time/frequency, and moieties. We explore emerging tissue modeling and molecular tools that improve resolution, specificity, and throughput.
Collapse
Affiliation(s)
- Qiang Huang
- Department of Pediatric Surgery, Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004 Shaanxi, China; Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Aliesha Garrett
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Shree Bose
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA
| | - Stephanie Blocker
- Center for In Vitro Microscopy, Duke University, Durham, NC 27708, USA
| | - Anne C Rios
- Princess Máxima Center for Pediatric Oncology, Utrecht 3584, the Netherlands; Department of Cancer Research, Oncode Institute, Hubrecht Institute-KNAW Utrecht, Utrecht 3584, the Netherlands
| | - Hans Clevers
- Princess Máxima Center for Pediatric Oncology, Utrecht 3584, the Netherlands; Department of Cancer Research, Oncode Institute, Hubrecht Institute-KNAW Utrecht, Utrecht 3584, the Netherlands; Hubrecht Institute, Royal Netherlands Academy of Arts and Sciences (KNAW) and University Medical Center (UMC) Utrecht, Utrecht 3584, the Netherlands
| | - Xiling Shen
- Department of Biomedical Engineering, Pratt School of Engineering, Duke University, Durham, NC 27708, USA.
| |
Collapse
|
30
|
Ota R. Photon counting detectors and their applications ranging from particle physics experiments to environmental radiation monitoring and medical imaging. Radiol Phys Technol 2021; 14:134-148. [PMID: 33742329 DOI: 10.1007/s12194-021-00615-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 03/09/2021] [Accepted: 03/11/2021] [Indexed: 01/01/2023]
Abstract
Photomultiplier tubes (PMTs) and silicon photomultipliers (SiPMs) have played essential roles in various applications, such as fundamental particle physics experiments, nuclear medicine, and environmental radiation monitoring, for several decades. Understandings their physical properties as well as present applications is indispensable for the development and future applications of these detectors. In this review, we describe the physical principles of PMTs and SiPMs and introduce various applications of these detectors.
Collapse
Affiliation(s)
- Ryosuke Ota
- Central Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, Japan. .,, 5000, Hirakuchi, Hamakita-ku, Hamamatsu, 434-8601, Japan.
| |
Collapse
|
31
|
Lai Y, Wang Q, Zhou S, Xie Z, Qi J, Cherry SR, Jin M, Chi Y, Du J. H 2RSPET: a 0.5 mm resolution high-sensitivity small-animal PET scanner, a simulation study. Phys Med Biol 2021; 66:065016. [PMID: 33571980 DOI: 10.1088/1361-6560/abe558] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
With the goal of developing a total-body small-animal PET system with a high spatial resolution of ∼0.5 mm and a high sensitivity >10% for mouse/rat studies, we simulated four scanners using the graphical processing unit-based Monte Carlo simulation package (gPET) and compared their performance in terms of spatial resolution and sensitivity. We also investigated the effect of depth-of-interaction (DOI) resolution on the spatial resolution. All the scanners are built upon 128 DOI encoding dual-ended readout detectors with lutetium yttrium oxyorthosilicate (LYSO) arrays arranged in 8 detector rings. The solid angle coverages of the four scanners are all ∼0.85 steradians. Each LYSO element has a cross-section of 0.44 × 0.44 mm2 and the pitch size of the LYSO arrays are all 0.5 mm. The four scanners can be divided into two groups: (1) H2RS110-C10 and H2RS110-C20 with 40 × 40 LYSO arrays, a ring diameter of 110 mm and axial length of 167 mm, and (2) H2RS160-C10 and H2RS160-C20 with 60 × 60 LYSO arrays, a diameter of 160 mm and axial length of 254 mm. C10 and C20 denote the crystal thickness of 10 and 20 mm, respectively. The simulation results show that all scanners have a spatial resolution better than 0.5 mm at the center of the field-of-view (FOV). The radial resolution strongly depends on the DOI resolution and radial offset, but not the axial resolution and tangential resolution. Comparing the C10 and C20 designs, the former provides better resolution, especially at positions away from the center of the FOV, whereas the latter has 2× higher sensitivity (∼10% versus ∼20%). This simulation study provides evidence that the 110 mm systems are a good choice for total-body mouse studies at a lower cost, whereas the 160 mm systems are suited for both total-body mouse and rat studies.
Collapse
Affiliation(s)
- Youfang Lai
- Department of Physics, University of Texas at Arlington, Arlington, TX 76019, United States of America
| | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Gaudin É, Thibaudeau C, Arpin L, Leroux JD, Toussaint M, Beaudoin JF, Cadorette J, Paillé M, Pepin CM, Koua K, Bouchard J, Viscogliosi N, Paulin C, Fontaine R, Lecomte R. Performance evaluation of the mouse version of the LabPET II PET scanner. Phys Med Biol 2021; 66:065019. [PMID: 33412542 DOI: 10.1088/1361-6560/abd952] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The LabPET II is a new positron emission tomography technology platform designed to achieve submillimetric spatial resolution imaging using fully pixelated avalanche photodiodes-based detectors and highly integrated parallel front-end processing electronics. The detector was designed as a generic building block to develop devices for preclinical imaging of small to mid-sized animals and for clinical imaging of the human brain. The aim of this work is to assess the physical characteristics and imaging performance of the mouse version of LabPET II scanner following the NEMA NU4-2008 standard and using high resolution phantoms and in vivo imaging applications. A reconstructed spatial resolution of 0.78 mm (0.5 μ l) is measured close to the center of the radial field of view. With an energy window of 350 650 keV, the system absolute sensitivity is 1.2% and its maximum noise equivalent count rate reaches 61.1 kcps at 117 MBq. Submillimetric spatial resolution is achieved in a hot spot phantom and tiny bone structures were resolved with unprecedented contrast in the mouse. These results provide convincing evidence of the capabilities of the LabPET II technology for biomolecular imaging in preclinical research.
Collapse
Affiliation(s)
- Émilie Gaudin
- Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, Sherbrooke, QC, Canada
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|