1
|
Higgins ST, Sigmon SC, Tidey JW, Heil SH, Gaalema DE, Lee DC, DeSarno MJ, Klemperer EM, Menson KE, Cioe PA, Plucinski S, Wiley RC, Orr E. Reduced Nicotine Cigarettes and E-Cigarettes in High-Risk Populations: 3 Randomized Clinical Trials. JAMA Netw Open 2024; 7:e2431731. [PMID: 39240566 PMCID: PMC11380105 DOI: 10.1001/jamanetworkopen.2024.31731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Accepted: 07/11/2024] [Indexed: 09/07/2024] Open
Abstract
Importance Prohibiting the sale of commonly preferred e-cigarette flavors (eg, fruity and sweet) to discourage use among youths poses a risk of diminishing efforts to decrease smoking in adults. Objective To compare reductions in smoking achieved in adults with psychiatric conditions or lower educational level using very low nicotine content (VLNC) cigarettes alone, combined with e-cigarettes limited to tobacco flavor (TF), or combined with e-cigarettes in participant-preferred flavors. Design, Setting, and Participants Three randomized clinical trials were conducted for 16 weeks from October 2020 through November 2023 at the University of Vermont, Brown University, and Johns Hopkins University. Participants were adults who smoked daily and were not planning to quit in the next 30 days. These participants were from 3 at-risk populations: those with affective disorders, exemplifying mental illness; those with opioid use disorder, exemplifying substance use disorders; and females of reproductive age with a high-school education or less, exemplifying lower educational level. Participants were randomly assigned to 1 of 4 experimental conditions: (1) normal nicotine content (NNC) cigarettes only; (2) VLNC cigarettes only; (3) VLNC cigarettes plus e-cigarettes with classic TF (hereafter, VLNC + TF); and (4) VLNC cigarettes plus e-cigarettes with preferred flavors (hereafter, VLNC + PF). Interventions The NNC cigarettes contained 15.8 mg nicotine/g tobacco, the VLNC cigarettes contained 0.4 mg nicotine/g tobacco, the VLNC + TF had pods containing 5% nicotine by weight and only classic TF, and the VLNC + PF had pods containing 5% nicotine in 8 flavors (including fruity and sweet) from which participants selected 3 flavors. Main Outcomes and Measures The primary outcome was mean total cigarettes smoked per day (CPD) during week 16. Tobacco-related biomarkers were assessed, including total 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a tobacco-specific carcinogen. Results A total of 326 participants (mean [SD] age, 40.09 [10.79] years; 243 females [74.5%]) from 3 randomized clinical trials were included. The VLNC cigarettes decreased total CPD, with least square (LS) means (SEMs) of 22.54 (1.59) in the NNC, 14.32 (1.32) in the VLNC, 11.76 (1.18) in the VLNC + TF, and 7.63 (0.90) in the VLNC + PF conditions. Each VLNC condition differed significantly from NNC, with an adjusted mean difference (AMD) of -8.21 (95% CI, -12.27 to -4.16; P < .001) in the VLNC, -10.78 (95% CI, -14.67 to -6.90; P < .001) in the VLNC + TF, and -14.91 (95% CI, -18.49 to -11.33; P < .001) in the VLNC + PF conditions. Participants in the VLNC + PF condition also decreased smoking below the VLNC and the VLNC + TF conditions (AMDs, -6.70 [95% CI, -9.84 to -3.55; P < .001] and -4.13 [95% CI, -7.05 to -1.21; P = .02]); the VLNC and VLNC + TF conditions did not differ significantly. Consistent with decreases in CPD, NNAL levels in the VLNC + PF condition were lower than in all other conditions, with AMDs (in pmol/mg creatinine) of -0.94 (95% CI, -1.41 to -0.47; P < .001) compared with the NNC condition, -0.47 (95% CI, -0.87 to -0.08; P = .03) compared with the VLNC condition, and -0.46 (95% CI, -0.83 to -0.10; P = .04) compared with the VLNC + TF condition. Conclusions and Relevance These results provide further evidence that a reduced-nicotine standard for cigarettes has the potential to decrease smoking and tobacco-toxicant exposure in high-risk populations and that these effects may be enhanced when adults can access e-cigarettes in commonly preferred flavors. Trial Registration ClinicalTrials.gov Identifiers: NCT04092387, NCT04090879, NCT04092101.
Collapse
Affiliation(s)
- Stephen T. Higgins
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Stacey C. Sigmon
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Jennifer W. Tidey
- Center for Alcohol and Addiction Studies, Brown University, Providence, Rhode Island
| | - Sarah H. Heil
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Diann E. Gaalema
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Dustin C. Lee
- Behavioral Pharmacology Research Unit, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Michael J. DeSarno
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Elias M. Klemperer
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Katherine E. Menson
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Patricia A. Cioe
- Center for Alcohol and Addiction Studies, Brown University, Providence, Rhode Island
| | - Shirley Plucinski
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Rhiannon C. Wiley
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| | - Eva Orr
- University of Vermont Tobacco Center of Regulatory Science, University of Vermont, Burlington
| |
Collapse
|
2
|
Edwards KC, St.Helen G, Jacob P, Ozga JE, Stanton CA. Urinary anatalline and nicotelline cut-points to distinguish between exclusive and dual use of tobacco products. Biomarkers 2024; 29:352-360. [PMID: 39105562 PMCID: PMC11473223 DOI: 10.1080/1354750x.2024.2389047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 07/31/2024] [Indexed: 08/07/2024]
Abstract
OBJECTIVE This study measured anatalline and nicotelline, two minor tobacco alkaloids, to discriminate between exclusive smokeless tobacco (SLT) use, exclusive electronic nicotine delivery systems (ENDS) use, exclusive cigarette use, dual SLT and cigarette use, and dual ENDS and cigarette use. METHODS N = 664 urine samples from participants in the Population Assessment of Tobacco and Health Study were analyzed for anatalline and nicotelline. Geometric means and 95% confidence intervals were calculated for biomarker levels and their ratios. Non-parametric Receiver Operating Characteristic analyses were used to determine optimal cut-points of natural log-transformed biomarker ratios for distinguishing between tobacco use groups. RESULTS The anatalline/nicotelline ratio distinguished exclusive cigarette from exclusive SLT use (threshold = 18.1, sensitivity = 89.3%, specificity = 86.4%, AUC = 0.90), and exclusive SLT from exclusive ENDS use (threshold = 12.8, sensitivity = 96.4%, specificity = 76.3%, AUC = 0.90) very well, but had reduced sensitivity and specificity when distinguishing exclusive cigarette from exclusive ENDS or any dual use with cigarettes. CONCLUSIONS This research fills a gap in understanding the public health consequences of SLT and ENDS use by providing objective measures that can signal use of these products alone or in combination with cigarettes.
Collapse
Affiliation(s)
| | - Gideon St.Helen
- University of California, San Francisco, San Francisco, CA, USA
| | - Peyton Jacob
- University of California, San Francisco, San Francisco, CA, USA
| | | | | |
Collapse
|
3
|
Glantz SA, Nguyen N, Oliveira da Silva AL. Population-Based Disease Odds for E-Cigarettes and Dual Use versus Cigarettes. NEJM EVIDENCE 2024; 3:EVIDoa2300229. [PMID: 38411454 DOI: 10.1056/evidoa2300229] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
BACKGROUND: E-cigarettes are promoted as less harmful than cigarettes. There has not been a direct comparison of health effects of e-cigarettes or dual use (concurrently using e-cigarettes and cigarettes) with those of cigarettes in the general population. METHODS: Studies in PubMed, EMBASE, Web of Science, and PsychINFO published through October 1, 2023, were pooled in a random-effects meta-analysis if five or more studies were identified with a disease outcome. We assessed risk of bias with Risk Of Bias In Non-randomized Studies of Exposure and certainty with Grading of Recommendations, Assessment, Development, and Evaluations. Outcomes with fewer studies were summarized but not pooled. RESULTS: We identified 124 odds ratios (94 cross-sectional and 30 longitudinal) from 107 studies. Pooled odds ratios for current e-cigarette versus cigarette use were not different for cardiovascular disease (odds ratio, 0.81; 95% confidence interval, 0.58 to 1.14), stroke (0.73; 0.47 to 1.13), or metabolic dysfunction (0.99; 0.91 to 1.09) but were lower for asthma (0.84; 0.74 to 0.95), chronic obstructive pulmonary disease (0.53; 0.38 to 0.74), and oral disease (0.87; 0.76 to 1.00). Pooled odds ratios for dual use versus cigarettes were increased for all outcomes (range, 1.20 to 1.41). Pooled odds ratios for e-cigarettes and dual use compared with nonuse of either product were increased (e-cigarette range, 1.24 to 1.47; dual use, 1.49 to 3.29). All included studies were assessed as having a low risk of bias. Results were generally not sensitive to study characteristics. Limited studies of other outcomes suggest that e-cigarette use is associated with additional diseases. CONCLUSIONS: There is a need to reassess the assumption that e-cigarette use provides substantial harm reduction across all cigarette-caused diseases, particularly accounting for dual use.
Collapse
Affiliation(s)
| | - Nhung Nguyen
- Center for Tobacco Control Research and Education, University of California, San Francisco, San Francisco
| | | |
Collapse
|
4
|
Addicott MA, Sutfin EL, Reynolds LM, Donny E, Matich EK, Hsu PC. Biochemical validation of self-reported electronic nicotine delivery system and tobacco heaviness of use. Exp Clin Psychopharmacol 2023; 31:715-723. [PMID: 36107700 PMCID: PMC10184506 DOI: 10.1037/pha0000604] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Research on tobacco use disorder relies on a combination of self-reported use (e.g., cigarettes per day) and biochemical validation to quantify heaviness of use. However, electronic nicotine delivery system (ENDS) users may be unaware of how much they have vaped per day. The aim of this study was to test the relationship between self-reported heaviness of ENDS/tobacco use and nicotine biomarkers. Young adults (n = 30) who currently use ENDS and other tobacco products completed a detailed tobacco use history, timeline follow-back, and an ENDS topography session. We evaluated the self-reports of own-brand ENDS use and tested correlations to determine which self-report measures of own-brand use, and which self-reported measures of puff topography, had the strongest correlations with urine and/or blood biomarkers of nicotine use. Participants reported using a variety of different ENDS devices and had a range of usage. The sum of the self-reported number of occasions or hours of ENDS use, along with the number of cigarettes and other tobacco products used, over the past 24 hr was significantly correlated with plasma cotinine levels. Puff topography measures correlated with increased nicotine concentrations, although participants underestimated the number of puffs they took during the topography session. This study provides preliminary evidence that summing together the hours of ENDS use, or the number of occasions of ENDS use, in addition to the number of other tobacco products used (i.e., cigarettes) based on self-report may be an accurate method of quantification. (PsycInfo Database Record (c) 2023 APA, all rights reserved).
Collapse
Affiliation(s)
- Merideth A. Addicott
- Department of Physiology and Pharmacology, Wake Forest School of Medicine, Winston-Salem, NC
| | - Erin L. Sutfin
- Department of Social Sciences and Health Policy, Wake Forest School of Medicine, Winston-Salem, NC
| | - Lindsay M. Reynolds
- Department of Epidemiology and Prevention, Wake Forest School of Medicine, Winston-Salem, NC
| | - Eric Donny
- Department of Physiology and Pharmacology, Wake Forest School of Medicine, Winston-Salem, NC
| | - Eryn K. Matich
- Department of Environmental and Occupational Health, Fay W. Boozman College of Public Health, University of Arkansas for Medical Sciences, Little Rock, AR
| | - Ping-Ching Hsu
- Department of Environmental and Occupational Health, Fay W. Boozman College of Public Health, University of Arkansas for Medical Sciences, Little Rock, AR
| |
Collapse
|
5
|
Perez MF, Yurieva M, Poddutoori S, Mortensen EM, Crotty Alexander LE, Williams A. Transcriptomic responses in the blood and sputum of cigarette smokers compared to e-cigarette vapers. Respir Res 2023; 24:134. [PMID: 37208747 PMCID: PMC10196320 DOI: 10.1186/s12931-023-02438-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 04/27/2023] [Indexed: 05/21/2023] Open
Abstract
RATIONALE Electronic (e)-cigarettes are popular among youth and cigarette smokers attempting to quit. Studies to date have focused on the utility of e-cigarettes as a smoking cessation tool, but the biological effects are largely unknown. OBJECTIVES To identify transcriptomic differences in the blood and sputum of e-cigarette users compared to conventional cigarettes smokers and healthy controls and describe biological pathways affected by these tobacco products. METHODS Cross-sectional analysis of whole blood and sputum RNA-sequencing data from 8 smokers, 9 e-cigarette users (e-cigs) and 4 controls. Weighted gene co-network analysis (WGCNA) identified gene module associations. Ingenuity Pathway Analysis (IPA) identified canonical pathways associated with tobacco products. MAIN RESULTS In blood, a three-group comparison showed 16 differentially expressed genes (DEGs); pair-wise comparison showed 7 DEGs between e-cigs and controls, 35 DEGs between smokers and controls, and 13 DEGs between smokers and e-cigs. In sputum, 438 DEGs were in the three-group comparison. In pair-wise comparisons, there were 2 DEGs between e-cigs and controls, 270 DEGs between smokers and controls, and 468 DEGs between smokers and e-cigs. Only 2 genes in the smokers vs. control comparison overlapped between blood and sputum. Most gene modules identified through WGCNA associated with tobacco product exposures also were associated with cotinine and exhaled CO levels. IPA showed more canonical pathways altered by conventional cigarette smoking than by e-cigarette use. CONCLUSION Cigarette smoking and e-cigarette use led to transcriptomic changes in both blood and sputum. However, conventional cigarettes induced much stronger transcriptomic responses in both compartments.
Collapse
Affiliation(s)
- Mario F Perez
- Department of Pulmonary, Critical Care and Sleep Medicine, University of Connecticut School of Medicine, Farmington, CT, USA.
| | - Marina Yurieva
- The Jackson Laboratory for Genomic Medicine, Farmington, CT, USA
| | | | - Eric M Mortensen
- Department of Pulmonary, Critical Care and Sleep Medicine, University of Connecticut School of Medicine, Farmington, CT, USA
| | - Laura E Crotty Alexander
- Division of Pulmonary Critical Care, Department of Medicine, University of California San Diego, San Diego, CA, USA
| | - Adam Williams
- The Jackson Laboratory for Genomic Medicine, Farmington, CT, USA
- Division of Allergy and Immunology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| |
Collapse
|
6
|
Holt NM, Shiffman S, Black RA, Goldenson NI, Sembower MA, Oldham MJ. Comparison of biomarkers of exposure among US adult smokers, users of electronic nicotine delivery systems, dual users and nonusers, 2018-2019. Sci Rep 2023; 13:7297. [PMID: 37147399 PMCID: PMC10163269 DOI: 10.1038/s41598-023-34427-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 04/29/2023] [Indexed: 05/07/2023] Open
Abstract
The harm caused by cigarette smoking is overwhelmingly due to byproducts of tobacco combustion. Electronic Nicotine Delivery Systems (ENDS) provide nicotine to users without combustion, and may support tobacco harm reduction among cigarette smokers who would not otherwise quit in the near term. Analyses of Wave 5 of the Population Assessment of Tobacco and Health (PATH) Study compared biomarkers of exposure (BOE) levels for nicotine, 3 metals, 2 tobacco-specific nitrosamines and 14 smoking-related volatile organic compounds in 151 exclusive ENDS users, 1341 exclusive cigarette smokers, 115 dual users (cigarettes and ENDS), and 1846 past 30-day nonusers of tobacco, adjusting for demographics. Nicotine exposure in ENDS users and dual users did not significantly differ from smokers. Among ENDS users, 16 of 18 other BOEs were significantly lower than smokers'; 9 BOEs were not significantly different from nonusers. Among dual users smoking < 10 cigarettes/day, 15 of 18 non-nicotine BOEs were significantly lower than smokers', whereas in dual users smoking ≥ 10 cigarettes per day none of the BOEs significantly differed from smokers'. In this representative sample of US adults, exclusive use of ENDS (vs. cigarette smoking) was associated with much lower exposures to many harmful chemicals associated with smoking-related disease. BOE levels in dual users were directly related to their cigarette consumption. These BOE data provide further evidence that ENDS expose users to substantially lower levels of toxicants than combustible cigarettes, confirming their potential for harm reduction.
Collapse
|
7
|
Abstract
This perspective summarizes available evidence on biomarkers of exposure in electronic nicotine delivery system (ENDS) users to aid the overall assessment of the health consequences of using ENDS. Identification of novel biomarkers of exposure specific to ENDS use remains challenging because chemicals emitted from ENDS devices have many familiar sources. The biomarker levels of many tobacco-related toxicants measured in biological samples collected from ENDS users did not differ significantly from non-users, except for nicotine metabolites and a small number of biomarkers of exposure to volatile organic compounds and tobacco-specific tobacco nitrosamines. Several studies have shown that while exposed to nicotine, long-term exclusive ENDS users showed significantly lower levels of toxicant biomarkers than cigarette smokers. Studies have also shown that concurrent users of ENDS and combustible cigarettes ('dual users') are not reducing overall exposure to harmful toxicants compared to exclusive cigarette smokers. Because of an absence of validated ENDS-specific biomarkers, we recommend combining several biomarkers to differentiate tobacco product user groups in population-based studies and monitor ENDS compliance in randomized controlled trials. Using a panel of biomarkers would provide a better understanding of health effects related to ENDS use.
Collapse
Affiliation(s)
- Maciej L Goniewicz
- Department of Health Behavior, Roswell Park Comprehensive Cancer Center, Elam and Carlton Streets, Buffalo NY 14226, United States
| |
Collapse
|
8
|
Mahabee-Gittens EM, Merianos AL, Stone L, Wullenweber CA, Quintana PJE, Hoh E, Dodder NG, Lopez-Galvez N, Matt GE. Hand nicotine as an independent marker of thirdhand smoke pollution in children's environments. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 849:157914. [PMID: 35952873 PMCID: PMC10199779 DOI: 10.1016/j.scitotenv.2022.157914] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 07/22/2022] [Accepted: 08/04/2022] [Indexed: 05/23/2023]
Abstract
BACKGROUND Hand nicotine (HN) levels measure children's exposure to tobacco smoke pollutants from thirdhand and secondhand smoke. HN is associated with urinary and salivary cotinine, but the associations of HN with other tobacco smoke exposure (TSE) markers remain unknown. OBJECTIVES We compared levels of HN and four urinary TSE biomarkers: cotinine, trans-3'-hydroxycotinine (3HC), nicotelline N-oxides, and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), and children's sociodemographic and TSE patterns. We also examined if HN is a plausible pathway for children's exposure to active smoking. METHODS Data were collected from 175 non-smoking patients (Mean (SD) age = 5.4 (3.4) years) who lived with ≥1 cigarette smoker(s). HN and TSE biomarker levels were determined using LC-MS/MS. Multivariate and multivariable regression analyses were conducted to examine associations between TSE markers and parent-reported measures, controlling for sociodemographics. RESULTS Of the five markers of TSE, cotinine (R2 = 0.221; p = 0.003) and HN (R2 = 0.247; p = 0.001) showed the strongest overall associations. Of the five markers, only cotinine showed significantly higher levels among Black children (β^=0.307,p<0.05) independent of age, reported exposure, and home smoking bans. Cotinine (β^=0.010,p<0.05), NNAL (β^=0.012,p<0.05), and HN (β^=0.011,p<0.05) showed significant positive associations with reported exposure independent of race, age, and home smoking bans. NNAL (β^=-0.285,p<0.05) and HN (β^=-0.336,p<0.05), but not cotinine, 3HC, and N-oxides, showed significantly lower levels among children who lived in homes with smoking bans. Child age, hand surface area, home smoking ban, and reported exposure independently accounted for 21 % of the variance in HN levels (p = 0.002). HN accounted for 30 % of the variance in cotinine independent of child race and child age. DISCUSSION HN levels were associated with modifiable tobacco-related behaviors and shows promise as a marker of sources of THS pollution in a child's environment not captured by measurement of urinary cotinine alone. HN levels provide additional information about TSE, complementing other biomarkers when assessing children's overall TSE.
Collapse
Affiliation(s)
- E Melinda Mahabee-Gittens
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA; Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| | - Ashley L Merianos
- School of Human Services, University of Cincinnati, Cincinnati, OH, USA
| | - Lara Stone
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Chase A Wullenweber
- Division of Emergency Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | | | - Eunha Hoh
- School of Public Health, San Diego State University, San Diego, CA, USA
| | - Nathan G Dodder
- School of Public Health, San Diego State University, San Diego, CA, USA; San Diego State University Research Foundation, San Diego, CA, USA
| | - Nicolas Lopez-Galvez
- School of Public Health, San Diego State University, San Diego, CA, USA; San Diego State University Research Foundation, San Diego, CA, USA
| | - Georg E Matt
- Department of Psychology, San Diego State University, San Diego, CA, USA
| |
Collapse
|
9
|
Mahabee-Gittens EM, Matt GE, Merianos AL. High Levels of the Carcinogenic Tobacco-Specific Nitrosamine NNAL and Associated Findings in Children of Smokers: A Case Series. Biomark Insights 2022; 17:11772719221118868. [PMID: 35982916 PMCID: PMC9379955 DOI: 10.1177/11772719221118868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 07/21/2022] [Indexed: 11/25/2022] Open
Abstract
High levels of NNAL, the tobacco smoke exposure (TSE) biomarker of the carcinogen 4-(Methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), indicate future cancer risk. A prior study of smokers' children revealed NNAL levels as high as active smokers. Therefore, we conducted a case series to examine the sociodemographics, TSE and clinical patterns, and other TSE biomarker levels in 9 children with extreme NNAL levels of >200 pg/ml to generate hypotheses and explore potential causes and implications. We identified 0 to 4-year-olds who presented to an emergency setting and lived with ⩾1 smoker who were part of a parental tobacco cessation trial (n = 461). Of these children, 52 had urinary NNAL, cotinine, and N-oxides results (n = 52). Nine children (17.3%) had NNAL levels >200 pg/ml, ranging from 206.4 to 1399.0 pg/ml (Median (Mdn) = 489.2 pg/ml; Interquartile Range (IQR) = 222.7-1289.3 pg/ml). The cotinine Mdn (IQR) was 38.5 (10.3-102.2) ng/ml and the N-oxides Mdn (IQR) = 93.8 (24.7-109.6) pg/ml. While all biomarker levels were alarmingly high, these young children would not have been flagged for very high cancer risk based on urinary cotinine levels alone. This underscores the critical role of comprehensive TSE biomarker measurement in capturing different TSE exposure patterns and assessing children's future risk for cancer and other TSE-related morbidities.
Collapse
Affiliation(s)
- E Melinda Mahabee-Gittens
- Division of Emergency Medicine,
Cincinnati Children’s Hospital Medical Center and University of Cincinnati College
of Medicine, Cincinnati, OH, USA
| | - Georg E Matt
- Department of Psychology, San Diego
State University, San Diego, CA, USA
| | - Ashley L Merianos
- School of Human Services, University of
Cincinnati, Cincinnati OH, USA
| |
Collapse
|
10
|
Validated single urinary assay designed for exposomic multi-class biomarkers of common environmental exposures. Anal Bioanal Chem 2022; 414:5943-5966. [PMID: 35754089 PMCID: PMC9326253 DOI: 10.1007/s00216-022-04159-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 05/24/2022] [Accepted: 05/31/2022] [Indexed: 11/01/2022]
Abstract
Epidemiological studies often call for analytical methods that use a small biospecimen volume to quantify trace level exposures to environmental chemical mixtures. Currently, as many as 150 polar metabolites of environmental chemicals have been found in urine. Therefore, we developed a multi-class method for quantitation of biomarkers in urine. A single sample preparation followed by three LC injections was optimized in a proof-of-approach for a multi-class method. The assay was validated to quantify 50 biomarkers of exposure in urine, belonging to 7 chemical classes and 16 sub-classes. The classes represent metabolites of 12 personal care and consumer product chemicals (PCPs), 5 polycyclic aromatic hydrocarbons (PAHs), 5 organophosphate flame retardants (OPFRs), 18 pesticides, 5 volatile organic compounds (VOCs), 4 tobacco alkaloids, and 1 drug of abuse. Human urine (0.2 mL) was spiked with isotope-labeled internal standards, enzymatically deconjugated, extracted by solid-phase extraction, and analyzed using high-performance liquid chromatography-tandem mass spectrometry. The methanol eluate from the cleanup was split in half and the first half analyzed for PCPs, PAH, and OPFR on a Betasil C18 column; and pesticides and VOC on a Hypersil Gold AQ column. The second half was analyzed for tobacco smoke metabolites and a drug of abuse on a Synergi Polar RP column. Limits of detection ranged from 0.01 to 1.0 ng/mL of urine, with the majority ≤0.5 ng/mL (42/50). Analytical precision, estimated as relative standard deviation of intra- and inter-batch uncertainty, variabilities, was <20%. Extraction recoveries ranged from 83 to 109%. Results from the optimized multi-class method were qualified in formal international proficiency testing programs. Further method customization options were explored and method expansion was demonstrated by inclusion of up to 101 analytes of endo- and exogenous chemicals. This exposome-scale assay is being used for population studies with savings of assay costs and biospecimens, providing both quantitative results and the discovery of unexpected exposures.
Collapse
|
11
|
Jacob P, Chan L, Cheung P, Bello K, Yu L, StHelen G, Benowitz NL. Minor Tobacco Alkaloids as Biomarkers to Distinguish Combusted Tobacco Use From Electronic Nicotine Delivery Systems Use. Two New Analytical Methods. Front Chem 2022; 10:749089. [PMID: 35720984 PMCID: PMC9198481 DOI: 10.3389/fchem.2022.749089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 05/04/2022] [Indexed: 11/13/2022] Open
Abstract
Biomarkers for the use of electronic nicotine delivery systems (ENDS) are desirable for studies of the health effects of electronic cigarettes and related devices. However, the aerosols inhaled from these devices do not contain substances that are unique to this class of products, i.e., substances that are not present in cigarette smoke or those that do not have common environmental or dietary sources. Consequently, identifying selective biomarkers for ENDS use remains a challenge. If co-use of conventional tobacco products can be definitively ruled out, then nicotine and its metabolites are suitable for assessing exposure. Self-reports from questionnaires are often used to obtain information on product use. But self-reports may not always be accurate, and are not amenable to obtaining quantitative information on exposure. An alternative approach is to use selective biomarkers for conventional tobacco products to definitively rule out their use. In this article, we describe two new LC-MS/MS methods for the minor tobacco alkaloids anabasine, anatabine, nicotelline, anatalline, and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a tobacco-specific nitrosamine metabolite, all biomarkers that are selective for the use of conventional tobacco products. Applications of these biomarkers in studies of ENDS use and dual use of ENDS and conventional tobacco products are also discussed.
Collapse
|
12
|
Mahabee-Gittens EM, Matt GE, Ding L, Merianos AL. Comparison of Levels of Three Tobacco Smoke Exposure Biomarkers in Children of Smokers. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph182211803. [PMID: 34831559 PMCID: PMC8622785 DOI: 10.3390/ijerph182211803] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 11/08/2021] [Accepted: 11/08/2021] [Indexed: 12/13/2022]
Abstract
Objectives: Cotinine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), and N-oxides are biomarkers of tobacco smoke exposure (TSE) used to assess short- and longer-term TSE. The objective of this study was to assess the associations between these TSE biomarkers, sociodemographics, parental smoking, and child TSE patterns among 0–17-year-olds. Methods: A convenience sample of 179 pediatric patients (mean (SD) age = 7.9 (4.3) years) who lived with ≥1 smoker and who had parental assessments completed and urine samples analyzed for the three TSE biomarkers of interest were included. Biomarker levels were log-transformed, univariate regression models were built and Pearson correlations were assessed. Results: In total, 100% of children had detectable levels of cotinine and >96% had detectable NNAL and N-oxide levels. The geometric means of cotinine, NNAL, and N-oxide levels were 10.1 ng/mL, 25.3 pg/mL, and 22.9 pg/mL, respectively. The mean (SD) number of daily cigarettes smoked by parents was 10.6 (6.0) cigarettes. Child age negatively correlated with urinary cotinine (r = −0.202, p = 0.007) and log NNAL levels (r = −0.275, p < 0.001). The highest log-cotinine levels were in children who were younger, of African American race, and whose parents had a lower education, an annual income ≤USD15,000, and no smoking bans. The highest log-NNAL and N-oxide levels were in children whose parents had a lower education, had no smoking bans, and were around higher numbers of cigarettes. Conclusion: Children of smokers who were younger, African American, and had no smoking bans had the highest TSE biomarker levels. Targeted interventions are needed to reduce TSE levels among high-risk children.
Collapse
Affiliation(s)
- E. Melinda Mahabee-Gittens
- Division of Emergency Medicine, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH 45229, USA
- Correspondence: ; Tel.: +1-513-636-7966; Fax: +1-513-636-7967
| | - Georg E. Matt
- Department of Psychology, San Diego State University, San Diego, CA 92123, USA;
| | - Lili Ding
- Division of Biostatistics and Epidemiology, Cincinnati Children’s Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH 45229, USA;
| | - Ashley L. Merianos
- School of Human Services, University of Cincinnati, Cincinnati, OH 45221, USA;
| |
Collapse
|
13
|
Abstract
Over the past decade, new emerging tobacco and nicotine-delivery products have changed the tobacco landscape. Especially, electronic cigarettes (ECs) have been suggested to be considered for tobacco harm reduction, reinforcing the need to identify novel biomarkers of exposure (BoE) specific to the EC use as this would complement exposure assessment and product compliance monitoring. Therefore, a sensitive LC-MS/MS method for the quantification of 1,2-propylene glycol (PG) and glycerol (G), the main e-liquid constituents, was established. PG and G were analyzed in plasma and urine samples from a clinical study comparing five nicotine product user groups, users of combustible cigarettes (CC), electronic cigarettes (EC), heated tobacco products (HTP), oral tobacco (OT), and oral/dermal nicotine delivery products (used for nicotine replacement therapy, NRT) with a control group of non-users (NU). Data demonstrate significantly elevated PG levels in urine and plasma in EC users compared to users of CC, HTP, NRT, OT as well as NU. In addition, PG in plasma and urine of vapers significantly correlated with nicotine (plasma) and total nicotine equivalents (urine), biomarkers reflecting product consumption, emphasizing the high specificity of PG as a BoE for EC consumption. We therefore suggest the use of PG as BoE in urine and/or plasma in order to monitor EC use compliance in exposure assessments.
Collapse
|
14
|
Kim T, Kang J. Association between dual use of e-cigarette and cigarette and chronic obstructive pulmonary disease: an analysis of a nationwide representative sample from 2013 to 2018. BMC Pulm Med 2021; 21:231. [PMID: 34256746 PMCID: PMC8278700 DOI: 10.1186/s12890-021-01590-8] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Accepted: 07/04/2021] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND The association between the dual use of electronic cigarette (e-cigarette) and conventional cigarettes (c-cigarette) and spirometry-defined chronic obstructive pulmonary disease (COPD) has not been studied thoroughly. METHODS A total of 47,217 participants were identified in the 2013-2018 Korea National Health and Nutrition Examination Survey; of them, 12,919 participants aged ≥ 40 who underwent spirometry and had no missing data were enrolled. Pulmonary function testing, urinary cotinine, and urinary 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) levels were compared between dual users, current smokers, former smokers, and non-users using complex sample linear regression analysis. The odds ratio (OR) for COPD was calculated using a complex sample logistic regression model after adjusting for covariates. RESULTS Among current e-cigarette users, approximately 85% of the participants used c-cigarette concurrently, and 1.3% of all the participants were dual users (2.3% in males and 0.1% in females). Both dual users and current smokers showed higher levels of urine cotinine and NNAL than non-users and former smokers. The weighted prevalence of COPD was the highest in dual users (13.8% for all participants and 14.1% for males). The multivariate-adjusted OR of COPD for male dual users, compared to non-users, was 3.46 (Ptrend < 0.001). The OR for COPD was 3.10 (Ptrend < 0.001) in middle-aged (40-64 years) and 3.70 (Ptrend < 0.001) in older (≥ 65 years) men. In females, the association was not observed and could not be precisely measured because of the small proportion of the smoking population. CONCLUSIONS Dual use of e-cigarette and c-cigarette is associated with COPD in males.
Collapse
Affiliation(s)
- Taeyun Kim
- Division of Pulmonology, Department of Internal Medicine, The Armed Forces Goyang Hospital, Goyang-si, Republic of Korea
| | - Jihun Kang
- Department of Family Medicine, Kosin University College of Medicine, Kosin University Gospel Hospital, 262 Gamcheon-ro, Seo-gu, Busan, Republic of Korea.
| |
Collapse
|
15
|
Cohen G, Goldenson NI, Bailey PC, Chan S, Shiffman S. Changes in Biomarkers of Cigarette Smoke Exposure After 6 Days of Switching Exclusively or Partially to Use of the JUUL System with Two Nicotine Concentrations: A Randomized Controlled Confinement Study in Adult Smokers. Nicotine Tob Res 2021; 23:2153-2161. [PMID: 34161586 PMCID: PMC8570669 DOI: 10.1093/ntr/ntab134] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Accepted: 06/21/2021] [Indexed: 02/07/2023]
Abstract
Introduction Evidence suggests that cigarette smokers who switch to electronic nicotine delivery systems (ENDS) reduce their exposure to harmful toxicants and carcinogens. It is unclear if dual-use is associated with decreases in exposure to toxicants. Methods This parallel-group confinement study assessed changes in biomarkers of exposure (BOEs) over six days among healthy adult smokers who were randomized into 1 of 11 study groups: eight JUUL-brand System (JUUL) groups (4 JUUL flavors [Virginia Tobacco, Menthol, Mint, Mango] × 2 nicotine concentrations [5.0% or 3.0% by weight]); Dual-Use group used preferred JUUL flavor (5.0% nicotine) and ≤50% usual brand (UB) cigarettes/day; UB Cigarette group and one group abstained from all tobacco/nicotine product use (Abstinence group). Urine and blood analysis assessed changes in primary BOE endpoints (NNAL, 3-HPMA, MHBMA, S-PMA COHb) and secondary BOE endpoints (NNN, HMPMA, CEMA, 1-OHP, O-toluidine, 2-NA, 4-ABP) among 279 adult smokers. Results In JUUL groups, median percent reductions in primary BOEs (Day 6–Baseline) were 90%–≥100% of Abstinence; there were no significant differences between JUUL groups and Abstinence. All reductions in JUUL groups were substantially and statistically significantly greater than reductions in the UB Cigarette group (ps < 0.025). Median reductions in primary BOEs in the Dual-Use group were 43%–55% of Abstinence. Similar results were observed for secondary BOEs. Conclusion This study suggests that the use of JUUL as a complete or partial substitute (i.e., dual-use with ≥50% reduction in cigarette consumption) for combustible cigarettes can substantially reduce exposure to multiple toxins associated with cigarette smoking. Implications This study adds to the growing body of evidence supporting the utility of ENDS products as potentially reduced-harm alternatives to cigarettes for adult smokers. Adult smokers who switched completely from cigarette smoking to use of the JUUL System (“JUUL”) in two nicotine concentrations (5.0% and 3.0%) and four flavors significantly reduced their exposure to multiple classes of cigarette-related toxicants. Additionally, smokers who used JUUL and continued smoking but reduced their daily cigarette consumption by ≥50% (dual users) also significantly reduced their toxicant exposure compared to cigarette smoking.
Collapse
Affiliation(s)
- Gal Cohen
- Juul Labs, Inc., Washington, DC, USA
- Corresponding Author: Gal Cohen, PhD, Juul Labs, Inc., 1000 F Street NW, Suite 800, Washington, D.C, 20004, USA. E-mail:
| | | | | | | | | |
Collapse
|
16
|
Sibul F, Burkhardt T, Kachhadia A, Pilz F, Scherer G, Scherer M, Pluym N. Identification of biomarkers specific to five different nicotine product user groups: Study protocol of a controlled clinical trial. Contemp Clin Trials Commun 2021; 22:100794. [PMID: 34189337 PMCID: PMC8219643 DOI: 10.1016/j.conctc.2021.100794] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 02/09/2021] [Accepted: 05/23/2021] [Indexed: 01/03/2023] Open
Abstract
Background Assessing biomarker profiles in various body fluids is of large value to discern between the sole use of nicotine products. In particular, the assessment of the product compliance is required for long-term clinical studies. The objective of this study was the identification of biomarkers and biomarker patterns in body fluids, to distinguish between combustibles, heated tobacco products, electronic cigarettes, oral tobacco and oral/dermal nicotine products used for nicotine replacement therapy (NRT), as well as a control group of non-users. Methods A controlled, single-center study was conducted with 60 healthy subjects, divided into 6 groups (5 nicotine product user groups and one non-user group) based on their sole use of the products of choice. The subjects were confined for 76 h, during which, free and uncontrolled use of the products was provided. Sample collections were performed according to the study time schedule provided in Table 2. The primary outcome will be validated through analysis of the collected biospecimens (urine, blood, saliva, exhaled breath and exhaled breath condensate) by means of untargeted omics approaches (i.e. exposomics, breathomics and adductomics). Secondary outcome will include established biomarker quantification methods to allow for the identification of typical biomarker patterns. Statistical analysis tools will be used to specifically discriminate different product use categories. Results/Conclusions The clinical trial was successfully completed in May 2020, resulting in sample management and preparations for the quantitative and qualitative analyses. This work will serve as a solid basis to discern between biomarker profiles of different nicotine product user groups. The knowledge collected during this research will be required to develop prototype diagnostic tools that can reliably assess the differences and evaluate possible health risks of various nicotine products.
Collapse
Affiliation(s)
- Filip Sibul
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Therese Burkhardt
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Alpeshkumar Kachhadia
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Fabian Pilz
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Gerhard Scherer
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Max Scherer
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| | - Nikola Pluym
- Analytisch-Biologisches Forschungslabor GmbH, Semmelweisstr. 5, 82152 Planegg, Germany
| |
Collapse
|
17
|
Wang Q, Ji X, Rahman I. Dysregulated Metabolites Serve as Novel Biomarkers for Metabolic Diseases Caused by E-Cigarette Vaping and Cigarette Smoking. Metabolites 2021; 11:metabo11060345. [PMID: 34072305 PMCID: PMC8229291 DOI: 10.3390/metabo11060345] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/21/2021] [Accepted: 05/24/2021] [Indexed: 12/31/2022] Open
Abstract
Metabolites are essential intermediate products in metabolism, and metabolism dysregulation indicates different types of diseases. Previous studies have shown that cigarette smoke dysregulated metabolites; however, limited information is available with electronic cigarette (e-cig) vaping. We hypothesized that e-cig vaping and cigarette smoking alters systemic metabolites, and we propose to understand the specific metabolic signature between e-cig users and cigarette smokers. Plasma from non-smoker controls, cigarette smokers, and e-cig users was collected, and metabolites were identified by UPLC-MS (ultra-performance liquid chromatography mass spectrometer). Nicotine degradation was activated by e-cig vaping and cigarette smoking with increased concentrations of cotinine, cotinine N-oxide, (S)-nicotine, and (R)-6-hydroxynicotine. Additionally, we found significantly decreased concentrations in metabolites associated with tricarboxylic acid (TCA) cycle pathways in e-cig users versus cigarette smokers, such as d-glucose, (2R,3S)-2,3-dimethylmalate, (R)-2-hydroxyglutarate, O-phosphoethanolamine, malathion, d-threo-isocitrate, malic acid, and 4-acetamidobutanoic acid. Cigarette smoking significant upregulated sphingolipid metabolites, such as d-sphingosine, ceramide, N-(octadecanoyl)-sphing-4-enine, N-(9Z-octadecenoyl)-sphing-4-enine, and N-[(13Z)-docosenoyl]-sphingosine, versus e-cig vaping. Overall, e-cig vaping dysregulated TCA cycle-related metabolites while cigarette smoking altered sphingolipid metabolites. Both e-cig and cigarette smoke increased nicotinic metabolites. Therefore, specific metabolic signatures altered by e-cig vaping and cigarette smoking could serve as potential systemic biomarkers for early pathogenesis of cardiopulmonary diseases.
Collapse
Affiliation(s)
- Qixin Wang
- Department of Environmental Medicine, School of Medicine and Dentistry, University of Rochester Medical Center, Rochester, NY 14642, USA;
| | - Xiangming Ji
- Department of Nutrition, Byrdine F. Lewis School of Nursing and Health Professions, Georgia State University, Atlanta, GA 30302, USA;
| | - Irfan Rahman
- Department of Environmental Medicine, School of Medicine and Dentistry, University of Rochester Medical Center, Rochester, NY 14642, USA;
- Correspondence:
| |
Collapse
|
18
|
Benowitz NL, Bernert JT, Foulds J, Hecht SS, Jacob P, Jarvis MJ, Joseph A, Oncken C, Piper ME. Biochemical Verification of Tobacco Use and Abstinence: 2019 Update. Nicotine Tob Res 2020; 22:1086-1097. [PMID: 31570931 DOI: 10.1093/ntr/ntz132] [Citation(s) in RCA: 333] [Impact Index Per Article: 83.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/31/2019] [Indexed: 12/21/2022]
Abstract
BACKGROUND The changing prevalence and patterns of tobacco use, the advent of novel nicotine delivery devices, and the development of new biomarkers prompted an update of the 2002 Society for Research on Nicotine and Tobacco (SRNT) report on whether and how to apply biomarker verification for tobacco use and abstinence. METHODS The SRNT Treatment Research Network convened a group of investigators with expertise in tobacco biomarkers to update the recommendations of the 2002 SNRT Biochemical Verification Report. RESULTS Biochemical verification of tobacco use and abstinence increases scientific rigor and is recommended in clinical trials of smoking cessation, when feasible. Sources, appropriate biospecimens, cutpoints, time of detection windows and analytic methods for carbon monoxide, cotinine (including over the counter tests), total nicotine equivalents, minor tobacco alkaloids, and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol are reviewed, as well as biochemical approaches to distinguishing cigarette smoking from use of electronic nicotine delivery devices (ENDS). CONCLUSIONS Recommendations are provided for whether and how to use biochemical verification of tobacco use and abstinence. Guidelines are provided on which biomarkers to use, which biospecimens to use, optimal cutpoints, time windows to detection, and methodology for biochemical verifications. Use of combinations of biomarkers is recommended for assessment of ENDS use. IMPLICATIONS Biochemical verification increases scientific rigor, but there are drawbacks that need to be assessed to determine whether the benefits of biochemical verification outweigh the costs, including the cost of the assays, the feasibility of sample collection, the ability to draw clear conclusions based on the duration of abstinence, and the variability of the assay within the study population. This paper provides updated recommendations from the 2002 SRNT report on whether and how to use biochemical markers in determining tobacco use and abstinence.
Collapse
Affiliation(s)
- Neal L Benowitz
- Division of Clinical Pharmacology and Experimental Therapeutics, Departments of Medicine and Biopharmaceutical Sciences; Center for Tobacco Control Research and Education, University of California San Francisco, San Francisco, CA
| | - John T Bernert
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA
| | - Jonathan Foulds
- Departments of Public Health Sciences and Psychiatry, Penn State College of Medicine, Hershey, PA
| | - Stephen S Hecht
- Departments of Laboratory Medicine and Pathology, Pharmacology, and Medicinal Chemistry, University of Minnesota, Masonic Cancer Center, Minneapolis, MN
| | - Peyton Jacob
- Departments of Medicine and Psychiatry, University of California San Francisco, San Francisco, CA
| | - Martin J Jarvis
- Department of Behavioural Science and Health, University College London, London, UK
| | - Anne Joseph
- Department of Medicine, University of Minnesota Medical School, Minneapolis, MN
| | - Cheryl Oncken
- Department of Medicine, University of Connecticut, Farmington, CT
| | - Megan E Piper
- Center for Tobacco Research and Intervention, Department of Medicine, School of Medicine and Public Health, University of Wisconsin, Madison, WI
| |
Collapse
|