1
|
Chen HY, Versteeg RB, Mankowsky R, Puppin M, Leroy L, Sander M, Deng Y, Oggenfuss RA, Zamofing T, Böhler P, Pradervand C, Mozzanica A, Vetter S, Smolentsev G, Kerkhoff L, Lemke HT, Chergui M, Mancini GF. A setup for hard x-ray time-resolved resonant inelastic x-ray scattering at SwissFEL. STRUCTURAL DYNAMICS (MELVILLE, N.Y.) 2024; 11:024308. [PMID: 38586277 PMCID: PMC10998714 DOI: 10.1063/4.0000236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 03/04/2024] [Indexed: 04/09/2024]
Abstract
We present a new setup for resonant inelastic hard x-ray scattering at the Bernina beamline of SwissFEL with energy, momentum, and temporal resolution. The compact R = 0.5 m Johann-type spectrometer can be equipped with up to three crystal analyzers and allows efficient collection of RIXS spectra. Optical pumping for time-resolved studies can be realized with a broad span of optical wavelengths. We demonstrate the performance of the setup at an overall ∼180 meV resolution in a study of ground-state and photoexcited (at 400 nm) honeycomb 5d iridate α-Li2IrO3. Steady-state RIXS spectra at the iridium L3-edge (11.214 keV) have been collected and are in very good agreement with data collected at synchrotrons. The time-resolved RIXS transients exhibit changes in the energy loss region <2 eV, whose features mostly result from the hopping nature of 5d electrons in the honeycomb lattice. These changes are ascribed to modulations of the Ir-to-Ir inter-site transition scattering efficiency, which we associate to a transient screening of the on-site Coulomb interaction.
Collapse
Affiliation(s)
- Hui-Yuan Chen
- Lausanne Centre for Ultrafast Science (LACUS), ISIC, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Rolf B. Versteeg
- Lausanne Centre for Ultrafast Science (LACUS), ISIC, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | - Roman Mankowsky
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Michele Puppin
- Lausanne Centre for Ultrafast Science (LACUS), ISIC, École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne, Switzerland
| | | | - Mathias Sander
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Yunpei Deng
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | | | - Thierry Zamofing
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Pirmin Böhler
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Claude Pradervand
- Photon Science Division, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Aldo Mozzanica
- Photon Science Division, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Seraphin Vetter
- Photon Science Division, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Grigory Smolentsev
- Energy and Environment Research Division, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Linda Kerkhoff
- Sect. Crystallography, Institute of Geology and Mineralogy, University of Cologne, 50674 Köln, Germany
| | - Henrik T. Lemke
- SwissFEL, Paul Scherrer Institut (PSI), 5232 Villigen, Switzerland
| | - Majed Chergui
- Authors to whom correspondence should be addressed: and
| | | |
Collapse
|
2
|
Kim JK, Dietl C, Kim HWJ, Ha SH, Kim J, Said AH, Kim J, Kim BJ. Resonant inelastic X-ray scattering endstation at the 1C beamline of Pohang Light Source II. JOURNAL OF SYNCHROTRON RADIATION 2023; 30:643-649. [PMID: 36947164 PMCID: PMC10161893 DOI: 10.1107/s1600577523001625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 02/22/2023] [Indexed: 05/06/2023]
Abstract
An endstation for resonant inelastic X-ray scattering (RIXS), dedicated to operations in the hard X-ray regime, has been constructed at the 1C beamline of Pohang Light Source II. At the Ir L3-edge, a total energy resolution of 34.2 meV was achieved, close to the theoretical estimation of 34.0 meV, which considers factors such as the incident energy bandpass, intrinsic analyzer resolution, geometrical broadening of the spectrometer, finite beam-size effect and Johann aberration. The performance of the RIXS instrument is demonstrated by measuring the RIXS spectra of Sr2IrO4. The endstation can be easily reconfigured to measure energy-integrated intensities with very low background for diffuse scattering and diffraction experiments.
Collapse
Affiliation(s)
- Jin Kwang Kim
- Department of Physics, Pohang University of Science and Technology, Pohang 790-784, Republic of Korea
| | - Christopher Dietl
- Center for Artificial Low Dimensional Electronic Systems, Institute for Basic Science (IBS), 77 Cheongam-Ro, Pohang 37673, Republic of Korea
| | - Hyun Woo J Kim
- Department of Physics, Pohang University of Science and Technology, Pohang 790-784, Republic of Korea
| | - Seung Hyeok Ha
- Department of Physics, Pohang University of Science and Technology, Pohang 790-784, Republic of Korea
| | - Jimin Kim
- Center for Artificial Low Dimensional Electronic Systems, Institute for Basic Science (IBS), 77 Cheongam-Ro, Pohang 37673, Republic of Korea
| | - Ayman H Said
- Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA
| | - Jungho Kim
- Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA
| | - B J Kim
- Department of Physics, Pohang University of Science and Technology, Pohang 790-784, Republic of Korea
| |
Collapse
|
3
|
Simonelli L, Marini C, Ribo L, Homs R, Avila J, Heinis D, Preda I, Klementiev K. The CLEAR X-ray emission spectrometer available at the CLAESS beamline of ALBA synchrotron. JOURNAL OF SYNCHROTRON RADIATION 2023; 30:235-241. [PMID: 36601942 PMCID: PMC9814063 DOI: 10.1107/s1600577522009821] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 10/06/2022] [Indexed: 06/17/2023]
Abstract
The CLEAR X-ray emission spectrometer installed at the CLAESS beamline of the ALBA synchrotron is described. It is an energy-dispersive spectrometer based on Rowland circle geometry with 1 m-diameter circle. The energy dispersion is achieved by the combination of a diced analyzer crystal and a unidimensional detector. A single unconventional dynamically bent analyzer crystal (Si 111) permits a wide energy range to be covered, just by exploiting its different reflections (333, 444, 555, 777, 888): 6-22 keV, with a spectrometer efficiency that decreases above 11 keV because of the Si detector thickness (Mythen, 350 µm), while the relative scattering intensities for the Si 333, 444, 555, 777 and 888 reflections correspond to 36, 40, 21, 13 and 15, respectively. The provided energy resolution is typically below 1-2 eV and depends on the beam size, working Bragg angle and reflection exploited. In most cases the energy dispersion ranges from 10 to 20 eV and can be enlarged by working in the out-of-Rowland geometry up to 40 eV. The spectrometer works in full backscattering geometry with the beam passing through the two halves of the analyzer. The vacuum beam path and the particular geometry allow a typical average noise of only 0.5 counts per second per pixel. The spectrometer is mainly used for measuring emission lines and high-resolution absorption spectra, with a typical scanning time for highly concentrated systems of around half an hour, including several repeats. The intrinsic energy dispersion allows systematic collection of resonant X-ray emission maps by measuring high-resolution absorption spectra. Moreover, it allows spectra to be measured on a single-shot basis. Resonant inelastic X-ray scattering experiments to probe electronic excitations are feasible, although the spectrometer is not optimized for this purpose due to the limited energy resolution and scattering geometry provided. In that case, to minimize the quasi-elastic line, the spectrometer is able to rotate along the beam path. Advantages and disadvantages with respect to other existing spectrometers are highlighted.
Collapse
Affiliation(s)
- L. Simonelli
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - C. Marini
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - L. Ribo
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - R. Homs
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - J. Avila
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - D. Heinis
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - I. Preda
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
| | - K. Klementiev
- CELLS-ALBA Synchrotron Light Source, 08290 Cerdanyola del Vallès, Barcelona, Spain
- MAX IV Laboratory, Fotongatan 2, 225 94 Lund, Sweden
| |
Collapse
|
4
|
Edwards NP, Bargar JR, van Campen D, van Veelen A, Sokaras D, Bergmann U, Webb SM. A new μ-high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2022; 93:083101. [PMID: 36050052 PMCID: PMC9392580 DOI: 10.1063/5.0095229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 07/14/2022] [Indexed: 06/15/2023]
Abstract
Here, we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm2, allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ∼64.5°-82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.
Collapse
Affiliation(s)
- Nicholas P. Edwards
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | - John R. Bargar
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | - Douglas van Campen
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | - Arjen van Veelen
- Material Science and Technology Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - Dimosthenis Sokaras
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| | - Uwe Bergmann
- Physics Department, University of Wisonsin-Madison, 1150 University Avenue, Madison, Wisconsin 53706-1390, USA
| | - Samuel M. Webb
- Stanford Synchrotron Radiation Lightsource, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025, USA
| |
Collapse
|
5
|
Descamps A, Ofori-Okai BK, Baldwin JK, Chen Z, Fletcher LB, Glenzer SH, Hartley NJ, Hasting JB, Khaghani D, Mo M, Nagler B, Recoules V, Redmer R, Schörner M, Sun P, Wang YQ, White TG, McBride EE. Towards performing high-resolution inelastic X-ray scattering measurements at hard X-ray free-electron lasers coupled with energetic laser drivers. JOURNAL OF SYNCHROTRON RADIATION 2022; 29:931-938. [PMID: 35787558 PMCID: PMC9255572 DOI: 10.1107/s1600577522004453] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 04/26/2022] [Indexed: 06/15/2023]
Abstract
High-resolution inelastic X-ray scattering is an established technique in the synchrotron community, used to investigate collective low-frequency responses of materials. When fielded at hard X-ray free-electron lasers (XFELs) and combined with high-intensity laser drivers, it becomes a promising technique for investigating matter at high temperatures and high pressures. This technique gives access to important thermodynamic properties of matter at extreme conditions, such as temperature, material sound speed, and viscosity. The successful realization of this method requires the acquisition of many identical laser-pump/X-ray-probe shots, allowing the collection of a sufficient number of photons necessary to perform quantitative analyses. Here, a 2.5-fold improvement in the energy resolution of the instrument relative to previous works at the Matter in Extreme Conditions (MEC) endstation, Linac Coherent Light Source (LCLS), and the High Energy Density (HED) instrument, European XFEL, is presented. Some aspects of the experimental design that are essential for improving the number of photons detected in each X-ray shot, making such measurements feasible, are discussed. A careful choice of the energy resolution, the X-ray beam mode provided by the XFEL, and the position of the analysers used in such experiments can provide a more than ten-fold improvement in the photometrics. The discussion is supported by experimental data on 10 µm-thick iron and 50 nm-thick gold samples collected at the MEC endstation at the LCLS, and by complementary ray-tracing simulations coupled with thermal diffuse scattering calculations.
Collapse
Affiliation(s)
- A. Descamps
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
- Aeronautics and Astronautics Department, Stanford University, 450 Serra Mall, Stanford, CA 94305, USA
| | - B. K. Ofori-Okai
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - J. K. Baldwin
- Los Alamos National Laboratory, Bikini Atoll Road, Los Alamos, NM 87545, USA
| | - Z. Chen
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - L. B. Fletcher
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - S. H. Glenzer
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - N. J. Hartley
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - J. B. Hasting
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - D. Khaghani
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - M. Mo
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - B. Nagler
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - V. Recoules
- CEA/DAM DIF, F-91297 Arpajon Cedex, France
- Université Paris-Saclay, CEA, Laboratoire Matière en Conditions Extrêmes, 91680 Bruyères-le-Châtel, France
| | - R. Redmer
- Institut für Physik, Universität Rostock, Albert-Einstein-Straße 23, 18059 Rostock, Germany
| | - M. Schörner
- Institut für Physik, Universität Rostock, Albert-Einstein-Straße 23, 18059 Rostock, Germany
| | - P. Sun
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| | - Y. Q. Wang
- Los Alamos National Laboratory, Bikini Atoll Road, Los Alamos, NM 87545, USA
| | | | - E. E. McBride
- SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
- PULSE Institute, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025, USA
| |
Collapse
|
6
|
Longo A, Giannici F, Casaletto MP, Rovezzi M, Sahle CJ, Glatzel P, Joly Y, Martorana A. Dynamic Role of Gold d-Orbitals during CO Oxidation under Aerobic Conditions. ACS Catal 2022. [DOI: 10.1021/acscatal.1c05739] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Alessandro Longo
- ESRF - The European Synchrotron, CS 40220, 38043 Cedex 9 Grenoble, France
- Istituto per lo Studio dei Materiali Nanostrutturati, Consiglio Nazionale delle Ricerche, Via Ugo La Malfa 153, 90146 Palermo, Italy
| | - Francesco Giannici
- Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, I-90128 Palermo, Italy
| | - Maria Pia Casaletto
- Istituto per lo Studio dei Materiali Nanostrutturati, Consiglio Nazionale delle Ricerche, Via Ugo La Malfa 153, 90146 Palermo, Italy
| | - Mauro Rovezzi
- ESRF - The European Synchrotron, CS 40220, 38043 Cedex 9 Grenoble, France
- Universitè Grenoble Alpes, CNRS, IRD, Irstea, Météo France, OSUG, FAME, 71 Avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Christoph J. Sahle
- ESRF - The European Synchrotron, CS 40220, 38043 Cedex 9 Grenoble, France
| | - Pieter Glatzel
- ESRF - The European Synchrotron, CS 40220, 38043 Cedex 9 Grenoble, France
| | - Yves Joly
- Universitè Grenoble Alpes Inst NEEL, 38042 Grenoble (France) and CNRS, Inst NEEL, 38042 Grenoble, France
| | - Antonino Martorana
- Dipartimento di Fisica e Chimica, Università di Palermo, Viale delle Scienze, I-90128 Palermo, Italy
| |
Collapse
|
7
|
Zhou KJ, Walters A, Garcia-Fernandez M, Rice T, Hand M, Nag A, Li J, Agrestini S, Garland P, Wang H, Alcock S, Nistea I, Nutter B, Rubies N, Knap G, Gaughran M, Yuan F, Chang P, Emmins J, Howell G. I21: an advanced high-resolution resonant inelastic X-ray scattering beamline at Diamond Light Source. JOURNAL OF SYNCHROTRON RADIATION 2022; 29:563-580. [PMID: 35254322 PMCID: PMC8900866 DOI: 10.1107/s1600577522000601] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 01/17/2022] [Indexed: 05/27/2023]
Abstract
The I21 beamline at Diamond Light Source is dedicated to advanced resonant inelastic X-ray scattering (RIXS) for probing charge, orbital, spin and lattice excitations in materials across condensed matter physics, applied sciences and chemistry. Both the beamline and the RIXS spectrometer employ divergent variable-line-spacing gratings covering a broad energy range of 280-3000 eV. A combined energy resolution of ∼35 meV (16 meV) is readily achieved at 930 eV (530 eV) owing to the optimized optics and the mechanics. Considerable efforts have been paid to the design of the entire beamline, particularly the implementation of the collection mirrors, to maximize the X-ray photon throughput. The continuous rotation of the spectrometer over 150° under ultra high vacuum and a cryogenic manipulator with six degrees of freedom allow accurate mappings of low-energy excitations from solid state materials in momentum space. Most importantly, the facility features a unique combination of the high energy resolution and the high photon throughput vital for advanced RIXS applications. Together with its stability and user friendliness, I21 has become one of the most sought after RIXS beamlines in the world.
Collapse
Affiliation(s)
- Ke-Jin Zhou
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Andrew Walters
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | | | - Thomas Rice
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Matthew Hand
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Abhishek Nag
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Jiemin Li
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Stefano Agrestini
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Peter Garland
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Hongchang Wang
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Simon Alcock
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Ioana Nistea
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Brian Nutter
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Nicholas Rubies
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Giles Knap
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Martin Gaughran
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Fajin Yuan
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - Peter Chang
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - John Emmins
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| | - George Howell
- Diamond Light Source, Harwell Campus, Didcot OX11 0DE, United Kingdom
| |
Collapse
|
8
|
Kvashnina KO, Butorin SM. High-energy resolution X-ray spectroscopy at actinide M 4,5 and ligand K edges: what we know, what we want to know, and what we can know. Chem Commun (Camb) 2022; 58:327-342. [PMID: 34874022 PMCID: PMC8725612 DOI: 10.1039/d1cc04851a] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 11/15/2021] [Indexed: 12/20/2022]
Abstract
In recent years, scientists have progressively recognized the role of electronic structures in the characterization of chemical properties for actinide containing materials. High-energy resolution X-ray spectroscopy at the actinide M4,5 edges emerged as a promising direction because this method can probe actinide properties at the atomic level through the possibility of reducing the experimental spectral width below the natural core-hole lifetime broadening. Parallel to the technical developments of the X-ray method and experimental discoveries, theoretical models, describing the observed electronic structure phenomena, have also advanced. In this feature article, we describe the latest progress in the field of high-energy resolution X-ray spectroscopy at the actinide M4,5 and ligand K edges and we show that the methods are able to (a) provide fingerprint information on the actinide oxidation state and ground state characters (b) probe 5f occupancy, non-stoichiometry, defects, and ligand/metal ratio and (c) investigate the local symmetry and effects of the crystal field. We discuss the chemical aspects of the electronic structure in terms familiar to chemists and materials scientists and conclude with a brief description of new opportunities and approaches to improve the experimental methodology and theoretical analysis for f-electron systems.
Collapse
Affiliation(s)
- Kristina O Kvashnina
- The Rossendorf Beamline at ESRF, The European Synchrotron, CS40220, 38043 Grenoble Cedex 9, France.
- Institute of Resource Ecology, Helmholtz Zentrum Dresden-Rossendorf (HZDR), PO Box 510119, 01314 Dresden, Germany
- Department of Chemistry, Lomonosov Moscow State University, Moscow 119991, Russia
| | - Sergei M Butorin
- Condensed Matter Physics of Energy Materials, X-ray Photon Science, Department of Physics and Astronomy, Uppsala University, P.O. Box 516, SE-751 20 Uppsala, Sweden.
| |
Collapse
|
9
|
Bertinshaw J, Mayer S, Dill FU, Suzuki H, Leupold O, Jafari A, Sergueev I, Spiwek M, Said A, Kasman E, Huang X, Keimer B, Gretarsson H. IRIXS Spectrograph: an ultra high-resolution spectrometer for tender RIXS. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:1184-1192. [PMID: 34212883 PMCID: PMC8284409 DOI: 10.1107/s1600577521003805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 04/08/2021] [Indexed: 06/13/2023]
Abstract
The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L3-edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538-544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al2O3(110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L3-edge, in excellent agreement with ray-tracing simulations.
Collapse
Affiliation(s)
- Joel Bertinshaw
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
| | - Simon Mayer
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Frank-Uwe Dill
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Hakuto Suzuki
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
| | - Olaf Leupold
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Atefeh Jafari
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Ilya Sergueev
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Manfred Spiwek
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Ayman Said
- Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA
| | - Elina Kasman
- Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA
| | - Xianrong Huang
- Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA
| | - Bernhard Keimer
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
| | - Hlynur Gretarsson
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| |
Collapse
|
10
|
Hayama S, Boada R, Chaboy J, Birt A, Duller G, Cahill L, Freeman A, Amboage M, Keenan L, Diaz-Moreno S. Photon-in/photon-out spectroscopy at the I20-scanning beamline at diamond light source. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2021; 33:284003. [PMID: 33957610 DOI: 10.1088/1361-648x/abfe93] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 05/06/2021] [Indexed: 06/12/2023]
Abstract
A scanning multi-crystal x-ray emission spectrometer to perform photon-in/photon-out spectroscopy at the I20-Scanning beamline at Diamond Light Source is described. The instrument, equipped with three analyzer crystals, is based on a 1 m Rowland circle spectrometer operating in the vertical plane. The energy resolution of the spectrometer is of the order of 1 eV, having sufficient resolving power to overcome the core-hole lifetime broadening of most of the transition metalsK-edges. Examples showing the capability of the beamline for performing high energy resolution fluorescence detection x-ray absorption spectroscopy (HERFD-XAS), non-resonant x-ray emission spectroscopy (XES) and resonant x-ray emission spectroscopy are presented. The comparison of the Zn and MnK-edge HERFD-XANES of ZnO and MnO withab initiocalculations shows that the technique provides enhanced validation of the models by making subtle spectral features more visible.
Collapse
Affiliation(s)
- Shusaku Hayama
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Roberto Boada
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
- Department of Chemistry, Universitat Autònoma de Barcelona, 08193 Bellaterra, Barcelona, Spain
| | - Jesús Chaboy
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Adrian Birt
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Graham Duller
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Leo Cahill
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Adam Freeman
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Monica Amboage
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Luke Keenan
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Sofia Diaz-Moreno
- Diamond Light Source Ltd., Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| |
Collapse
|
11
|
Glatzel P, Harris A, Marion P, Sikora M, Weng TC, Guilloud C, Lafuerza S, Rovezzi M, Detlefs B, Ducotté L. The five-analyzer point-to-point scanning crystal spectrometer at ESRF ID26. JOURNAL OF SYNCHROTRON RADIATION 2021; 28:362-371. [PMID: 33399588 DOI: 10.1107/s1600577520015416] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 11/20/2020] [Indexed: 05/25/2023]
Abstract
X-ray emission spectroscopy in a point-to-point focusing geometry using instruments that employ more than one analyzer crystal poses challenges with respect to mechanical design and performance. This work discusses various options for positioning the components and provides the formulas for calculating their relative placement. Ray-tracing calculations were used to determine the geometrical contributions to the energy broadening including the source volume as given by the beam footprint on the sample. The alignment of the instrument is described and examples are given for the performance.
Collapse
Affiliation(s)
- Pieter Glatzel
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | | | - Philippe Marion
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Marcin Sikora
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Tsu Chien Weng
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Cyril Guilloud
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Sara Lafuerza
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Mauro Rovezzi
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Blanka Detlefs
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| | - Ludovic Ducotté
- ESRF - The European Synchrotron, 71 Avenue des Martyres, 38000 Grenoble, France
| |
Collapse
|
12
|
Honkanen AP, Huotari S. General method to calculate the elastic deformation and X-ray diffraction properties of bent crystal wafers. IUCRJ 2021; 8:102-115. [PMID: 33520246 PMCID: PMC7793001 DOI: 10.1107/s2052252520014165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 10/23/2020] [Indexed: 06/12/2023]
Abstract
Toroidally and spherically bent single crystals are widely employed as optical elements in hard X-ray spectrometry at synchrotron and free-electron laser light sources, and in laboratory-scale instruments. To achieve optimal spectrometer performance, a solid theoretical understanding of the diffraction properties of such crystals is essential. In this work, a general method to calculate the internal stress and strain fields of toroidally bent crystals and how to apply it to predict their diffraction properties is presented. Solutions are derived and discussed for circular and rectangular spherically bent wafers due to their prevalence in contemporary instrumentation.
Collapse
Affiliation(s)
- Ari-Pekka Honkanen
- Department of Physics, University of Helsinki, PO Box 64, FI-00014 Helsinki, Finland
| | - Simo Huotari
- Department of Physics, University of Helsinki, PO Box 64, FI-00014 Helsinki, Finland
| |
Collapse
|
13
|
|
14
|
Descamps A, Ofori-Okai BK, Appel K, Cerantola V, Comley A, Eggert JH, Fletcher LB, Gericke DO, Göde S, Humphries O, Karnbach O, Lazicki A, Loetzsch R, McGonegle D, Palmer CAJ, Plueckthun C, Preston TR, Redmer R, Senesky DG, Strohm C, Uschmann I, White TG, Wollenweber L, Monaco G, Wark JS, Hastings JB, Zastrau U, Gregori G, Glenzer SH, McBride EE. An approach for the measurement of the bulk temperature of single crystal diamond using an X-ray free electron laser. Sci Rep 2020; 10:14564. [PMID: 32884061 PMCID: PMC7471281 DOI: 10.1038/s41598-020-71350-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 08/06/2020] [Indexed: 11/25/2022] Open
Abstract
We present a method to determine the bulk temperature of a single crystal diamond sample at an X-Ray free electron laser using inelastic X-ray scattering. The experiment was performed at the high energy density instrument at the European XFEL GmbH, Germany. The technique, based on inelastic X-ray scattering and the principle of detailed balance, was demonstrated to give accurate temperature measurements, within [Formula: see text] for both room temperature diamond and heated diamond to 500 K. Here, the temperature was increased in a controlled way using a resistive heater to test theoretical predictions of the scaling of the signal with temperature. The method was tested by validating the energy of the phonon modes with previous measurements made at room temperature using inelastic X-ray scattering and neutron scattering techniques. This technique could be used to determine the bulk temperature in transient systems with a temporal resolution of 50 fs and for which accurate measurements of thermodynamic properties are vital to build accurate equation of state and transport models.
Collapse
Affiliation(s)
- A Descamps
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA.
- Aeronautics and Astronautics Department, Stanford University, Stanford, CA, 94305, USA.
| | - B K Ofori-Okai
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA
| | - K Appel
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - V Cerantola
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - A Comley
- Atomic Weapons Establishment, Aldermaston, Reading, RG7 4PR, UK
| | - J H Eggert
- Lawrence Livermore National Laboratory, Livermore, CA, 94550, USA
| | - L B Fletcher
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA
| | - D O Gericke
- Centre for Fusion, Space and Astrophysics, Department of Physics, University of Warwick, Coventry, CV4 7AL, UK
| | - S Göde
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - O Humphries
- Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU, UK
| | - O Karnbach
- Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU, UK
| | - A Lazicki
- Lawrence Livermore National Laboratory, Livermore, CA, 94550, USA
| | - R Loetzsch
- Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität Jena, Max-Wien-Platz 1, 07743, Jena, Germany
- Helmholtz-Institut Jena, Fröbelstieg 3, 07743, Jena, Germany
| | - D McGonegle
- Atomic Weapons Establishment, Aldermaston, Reading, RG7 4PR, UK
- Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU, UK
| | - C A J Palmer
- School of Mathematics and Physics, Queen's University, University Road BT7 1NN, Belfast, UK
| | - C Plueckthun
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - T R Preston
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - R Redmer
- Institut für Physik, Universität Rostock, A.-Einstein-Str. 23-24, 18059, Rostock, Germany
| | - D G Senesky
- Aeronautics and Astronautics Department, Stanford University, Stanford, CA, 94305, USA
| | - C Strohm
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
- Deutsches Elektronen Synchrotron, Notkestrasse 85, 22607, Hamburg, Germany
| | - I Uschmann
- Institut für Optik und Quantenelektronik, Friedrich-Schiller-Universität Jena, Max-Wien-Platz 1, 07743, Jena, Germany
- Helmholtz-Institut Jena, Fröbelstieg 3, 07743, Jena, Germany
| | - T G White
- University of Nevada, Reno, NV, 89557, USA
| | - L Wollenweber
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - G Monaco
- Dipartimento di Fisica, Università di Trento, Via Sommarive 14, 38123, Povo, TN, Italy
| | - J S Wark
- Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU, UK
| | - J B Hastings
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA
| | - U Zastrau
- European X-Ray Free-Electron Laser Facility GmbH, Holzkoppel 4, 22869, Schenefeld, Germany
| | - G Gregori
- Department of Physics, Clarendon Laboratory, University of Oxford, Parks Road, Oxford, OX1 3PU, UK
| | - S H Glenzer
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA
| | - E E McBride
- SLAC National Accelerator Laboratory, Menlo Park, CA, 94025, USA
| |
Collapse
|
15
|
Lafuerza S, Retegan M, Detlefs B, Chatterjee R, Yachandra V, Yano J, Glatzel P. New reflections on hard X-ray photon-in/photon-out spectroscopy. NANOSCALE 2020; 12:16270-16284. [PMID: 32760987 PMCID: PMC7808884 DOI: 10.1039/d0nr01983f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Analysis of the electronic structure and local coordination of an element is an important aspect in the study of the chemical and physical properties of materials. This is particularly relevant at the nanoscale where new phases of matter may emerge below a critical size. X-ray emission spectroscopy (XES) at synchrotron radiation sources and free electron lasers has enriched the field of X-ray spectroscopy. The spectroscopic techniques derived from the combination of X-ray absorption and emission spectroscopy (XAS-XES), such as resonant inelastic X-ray scattering (RIXS) and high energy resolution fluorescence detected (HERFD) XAS, are an ideal tool for the study of nanomaterials. New installations and beamline upgrades now often include wavelength dispersive instruments for the analysis of the emitted X-rays. With the growing use of XAS-XES, scientists are learning about the possibilities and pitfalls. We discuss some experimental aspects, assess the feasibility of measuring weak fluorescence lines in dilute, radiation sensitive samples, and present new experimental approaches for studying magnetic properties of colloidal nanoparticles directly in the liquid phase.
Collapse
Affiliation(s)
- Sara Lafuerza
- European Synchrotron Radiation Facility, 71 Avenue des Martyres, 38000 Grenoble, France.
| | | | | | | | | | | | | |
Collapse
|
16
|
Rovezzi M, Harris A, Detlefs B, Bohdan T, Svyazhin A, Santambrogio A, Degler D, Baran R, Reynier B, Noguera Crespo P, Heyman C, Van Der Kleij HP, Van Vaerenbergh P, Marion P, Vitoux H, Lapras C, Verbeni R, Kocsis MM, Manceau A, Glatzel P. TEXS: in-vacuum tender X-ray emission spectrometer with 11 Johansson crystal analyzers. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:813-826. [PMID: 32381786 PMCID: PMC7285681 DOI: 10.1107/s160057752000243x] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Accepted: 02/20/2020] [Indexed: 05/22/2023]
Abstract
The design and first results of a large-solid-angle X-ray emission spectrometer that is optimized for energies between 1.5 keV and 5.5 keV are presented. The spectrometer is based on an array of 11 cylindrically bent Johansson crystal analyzers arranged in a non-dispersive Rowland circle geometry. The smallest achievable energy bandwidth is smaller than the core hole lifetime broadening of the absorption edges in this energy range. Energy scanning is achieved using an innovative design, maintaining the Rowland circle conditions for all crystals with only four motor motions. The entire spectrometer is encased in a high-vacuum chamber that allocates a liquid helium cryostat and provides sufficient space for in situ cells and operando catalysis reactors.
Collapse
Affiliation(s)
- Mauro Rovezzi
- Université Grenoble Alpes, CNRS, IRD, Irstea, Météo France, OSUG, FAME, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | | | - Blanka Detlefs
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Timothy Bohdan
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Artem Svyazhin
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
- M. N. Miheev Institute of Metal Physics, Ural Branch of the Russian Academy of Science, 620990 Ekaterinburg, Russia
| | - Alessandro Santambrogio
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - David Degler
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Rafal Baran
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Benjamin Reynier
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Pedro Noguera Crespo
- Added Value Solutions (AVS), Pol. Ind. Sigma Xixilion Kalea 2, Bajo Pabellón 10, 20870 Elgoibar, Spain
| | | | - Hans-Peter Van Der Kleij
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Pierre Van Vaerenbergh
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Philippe Marion
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Hugo Vitoux
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Christophe Lapras
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Roberto Verbeni
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Menhard Menyhert Kocsis
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| | - Alain Manceau
- ISTerre, Université Grenoble Alpes, CNRS, CS 40700, 38058 Grenoble, France
| | - Pieter Glatzel
- European Synchrotron Radiation Facility, 71 avenue des Martyrs, CS 40220, 38043 Grenoble, France
| |
Collapse
|
17
|
Nowak SH, Armenta R, Schwartz CP, Gallo A, Abraham B, Garcia-Esparza AT, Biasin E, Prado A, Maciel A, Zhang D, Day D, Christensen S, Kroll T, Alonso-Mori R, Nordlund D, Weng TC, Sokaras D. A versatile Johansson-type tender x-ray emission spectrometer. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:033101. [PMID: 32259983 DOI: 10.1063/1.5121853] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2019] [Accepted: 02/13/2020] [Indexed: 05/23/2023]
Abstract
We present a high energy resolution x-ray spectrometer for the tender x-ray regime (1.6-5.0 keV) that was designed and operated at Stanford Synchrotron Radiation Lightsource. The instrument is developed on a Rowland geometry (500 mm of radius) using cylindrically bent Johansson analyzers and a position sensitive detector. By placing the sample inside the Rowland circle, the spectrometer operates in an energy-dispersive mode with a subnatural line-width energy resolution (∼0.32 eV at 2400 eV), even when an extended incident x-ray beam is used across a wide range of diffraction angles (∼30° to 65°). The spectrometer is enclosed in a vacuum chamber, and a sample chamber with independent ambient conditions is introduced to enable a versatile and fast-access sample environment (e.g., solid/gas/liquid samples, in situ cells, and radioactive materials). The design, capabilities, and performance are presented and discussed.
Collapse
Affiliation(s)
- S H Nowak
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - R Armenta
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - C P Schwartz
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Gallo
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - B Abraham
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A T Garcia-Esparza
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - E Biasin
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Prado
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - A Maciel
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Zhang
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Day
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - S Christensen
- National Renewable Energy Laboratory, 15013 Denver West Parkway, Golden, Colorado 80401, USA
| | - T Kroll
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - R Alonso-Mori
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Nordlund
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - T-C Weng
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| | - D Sokaras
- SLAC National Accelerator Laboratory, 2575 Sand Hill Rd., Menlo Park, California 94025, USA
| |
Collapse
|
18
|
Gretarsson H, Ketenoglu D, Harder M, Mayer S, Dill FU, Spiwek M, Schulte-Schrepping H, Tischer M, Wille HC, Keimer B, Yavaş H. IRIXS: a resonant inelastic X-ray scattering instrument dedicated to X-rays in the intermediate energy range. JOURNAL OF SYNCHROTRON RADIATION 2020; 27:538-544. [PMID: 32153295 PMCID: PMC7064114 DOI: 10.1107/s1600577519017119] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Accepted: 12/21/2019] [Indexed: 06/01/2023]
Abstract
A new resonant inelastic X-ray scattering (RIXS) instrument has been constructed at beamline P01 of the PETRA III synchrotron. This instrument has been named IRIXS (intermediate X-ray energy RIXS) and is dedicated to X-rays in the tender-energy regime (2.5-3.5 keV). The range covers the L2,3 absorption edges of many of the 4d elements (Mo, Tc, Ru, Rh, Pd and Ag), offering a unique opportunity to study their low-energy magnetic and charge excitations. The IRIXS instrument is currently operating at the Ru L3-edge (2840 eV) but can be extended to the other 4d elements using the existing concept. The incoming photons are monochromated with a four-bounce Si(111) monochromator, while the energy analysis of the outgoing photons is performed by a diced spherical crystal analyzer featuring (102) lattice planes of quartz (SiO2). A total resolution of 100 meV (full width at half-maximum) has been achieved at the Ru L3-edge, a number that is in excellent agreement with ray-tracing simulations.
Collapse
Affiliation(s)
- Hlynur Gretarsson
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Didem Ketenoglu
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
- Department of Engineering Physics, Faculty of Engineering, Ankara University, Ankara 06100, Turkey
| | - Manuel Harder
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Simon Mayer
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Frank-Uwe Dill
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Manfred Spiwek
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | | | - Markus Tischer
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Hans-Christian Wille
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
| | - Bernhard Keimer
- Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart, Germany
| | - Hasan Yavaş
- Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, D-22607 Hamburg, Germany
- SLAC National Accelerator Laboratory, 2757 Sand Hill Road, Menlo Park, CA 94025, USA
| |
Collapse
|
19
|
Allen AJ. Recent trends in crystallography - a current IUCr journals perspective. IUCRJ 2019; 6:984-987. [PMID: 31709052 PMCID: PMC6830219 DOI: 10.1107/s2052252519014507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This Editorial considers the impact of recent work published in IUCrJ and other IUCr journals, as well as the relationship between IUCrJ and the other journals, in terms of where the most cited recent papers are used.
Collapse
Affiliation(s)
- Andrew J. Allen
- Materials Measurement Science Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, USA
| |
Collapse
|
20
|
Rossi M, Henriquet C, Jacobs J, Donnerer C, Boseggia S, Al-Zein A, Fumagalli R, Yao Y, Vale JG, Hunter EC, Perry RS, Kantor I, Garbarino G, Crichton W, Monaco G, McMorrow DF, Krisch M, Moretti Sala M. Resonant inelastic X-ray scattering of magnetic excitations under pressure. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:1725-1732. [PMID: 31490164 DOI: 10.1107/s1600577519008877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Accepted: 06/21/2019] [Indexed: 06/10/2023]
Abstract
Resonant inelastic X-ray scattering (RIXS) is an extremely valuable tool for the study of elementary, including magnetic, excitations in matter. The latest developments of this technique have mostly been aimed at improving the energy resolution and performing polarization analysis of the scattered radiation, with a great impact on the interpretation and applicability of RIXS. Instead, this article focuses on the sample environment and presents a setup for high-pressure low-temperature RIXS measurements of low-energy excitations. The feasibility of these experiments is proved by probing the magnetic excitations of the bilayer iridate Sr3Ir2O7 at pressures up to 12 GPa.
Collapse
Affiliation(s)
- Matteo Rossi
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Christian Henriquet
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Jeroen Jacobs
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Christian Donnerer
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - Stefano Boseggia
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - Ali Al-Zein
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Roberto Fumagalli
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Yi Yao
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - James G Vale
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - Emily C Hunter
- Centre for Science at Extreme Conditions, University of Edinburgh, Mayfield Road, Edinburgh EH9 3JZ, UK
| | - Robin S Perry
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - Innokenty Kantor
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Gaston Garbarino
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Wilson Crichton
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Giulio Monaco
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Desmond F McMorrow
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - Michael Krisch
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| | - Marco Moretti Sala
- ESRF - The European Synchrotron, 71 Avenue des Martyrs, CS 40220, F-38043 Grenoble, France
| |
Collapse
|
21
|
Nag A, Bhowal S, Sala MM, Efimenko A, Dasgupta I, Ray S. Hopping-Induced Ground-State Magnetism in 6H Perovskite Iridates. PHYSICAL REVIEW LETTERS 2019; 123:017201. [PMID: 31386398 DOI: 10.1103/physrevlett.123.017201] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2019] [Revised: 04/05/2019] [Indexed: 06/10/2023]
Abstract
Investigation of elementary excitations has advanced our understanding of many-body physics governing most physical properties of matter. Recently spin-orbit excitons have drawn much attention, whose condensates near phase transitions exhibit Higgs mode oscillations, a long-sought-after physical phenomenon [A. Jain, et al., Nat. Phys. 13, 633 (2017)NPAHAX1745-247310.1038/nphys4077]. These critical transition points, resulting from competing spin-orbit coupling (SOC), local crystalline symmetry, and exchange interactions, are not obvious in iridium-based materials, where SOC prevails in general. Here, we present results of resonant inelastic x-ray scattering on a spin-orbital liquid Ba_{3}ZnIr_{2}O_{9} and three other 6H-hexagonal perovskite iridates that show magnetism, contrary to the nonmagnetic singlet ground state expected due to strong SOC. Our results show that substantial hopping between closely placed Ir^{5+} ions within Ir_{2}O_{9} dimers in these 6H iridates modifies spin-orbit coupled states and reduces spin-orbit excitation energies. Here, we are forced to use at least a two-site model to match the excitation spectrum going in-line with the strong intradimer hopping. Apart from SOC, low-energy physics of iridates is thus critically dependent on hopping and may not be ignored even for systems having moderate hopping, where the excitation spectra can be explained using an atomic model. SOC, which is generally found to be 0.4-0.5 eV in iridates, is scaled in effect down to ∼0.26 eV for the 6H systems, sustaining the hope of achieving quantum criticality by tuning Ir-Ir separation.
Collapse
Affiliation(s)
- A Nag
- School of Materials Science, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700032, India
| | - S Bhowal
- School of Physical Sciences, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700032, India
| | - M Moretti Sala
- ESRF-The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy
| | - A Efimenko
- ESRF-The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France
| | - I Dasgupta
- School of Physical Sciences, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700032, India
| | - Sugata Ray
- School of Materials Science, Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700032, India
| |
Collapse
|
22
|
Ingold G, Abela R, Arrell C, Beaud P, Böhler P, Cammarata M, Deng Y, Erny C, Esposito V, Flechsig U, Follath R, Hauri C, Johnson S, Juranic P, Mancini GF, Mankowsky R, Mozzanica A, Oggenfuss RA, Patterson BD, Patthey L, Pedrini B, Rittmann J, Sala L, Savoini M, Svetina C, Zamofing T, Zerdane S, Lemke HT. Experimental station Bernina at SwissFEL: condensed matter physics on femtosecond time scales investigated by X-ray diffraction and spectroscopic methods. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:874-886. [PMID: 31074452 PMCID: PMC6510206 DOI: 10.1107/s160057751900331x] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 03/07/2019] [Indexed: 05/22/2023]
Abstract
The Bernina instrument at the SwissFEL Aramis hard X-ray free-electron laser is designed for studying ultrafast phenomena in condensed matter and material science. Ultrashort pulses from an optical laser system covering a large wavelength range can be used to generate specific non-equilibrium states, whose subsequent temporal evolution can be probed by selective X-ray scattering techniques in the range 2-12 keV. For that purpose, the X-ray beamline is equipped with optical elements which tailor the X-ray beam size and energy, as well as with pulse-to-pulse diagnostics that monitor the X-ray pulse intensity, position, as well as its spectral and temporal properties. The experiments can be performed using multiple interchangeable endstations differing in specialization, diffractometer and X-ray analyser configuration and load capacity for specialized sample environment. After testing the instrument in a series of pilot experiments in 2018, regular user operation begins in 2019.
Collapse
Affiliation(s)
- Gerhard Ingold
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
- Correspondence e-mail: ,
| | - Rafael Abela
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | - Paul Beaud
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Pirmin Böhler
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Marco Cammarata
- Institut de Physique de Rennes, Université de Rennes, 35042 Rennes CEDEX, France
| | - Yunpei Deng
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Christian Erny
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Vincent Esposito
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Uwe Flechsig
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Rolf Follath
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Christoph Hauri
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Steven Johnson
- Institute for Quantum Electronics, Eidgenössische Technische Hochschule (ETH) Zürich, CH-8093 Zurich, Switzerland
| | - Pavle Juranic
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | - Roman Mankowsky
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Aldo Mozzanica
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | | | | | - Luc Patthey
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Bill Pedrini
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Jochen Rittmann
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Leonardo Sala
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Matteo Savoini
- Institute for Quantum Electronics, Eidgenössische Technische Hochschule (ETH) Zürich, CH-8093 Zurich, Switzerland
| | - Cristian Svetina
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Thierry Zamofing
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Serhane Zerdane
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
| | - Henrik Till Lemke
- SwissFEL, Paul Scherrer Institut, 5232 Villigen PSI, Switzerland
- Correspondence e-mail: ,
| |
Collapse
|
23
|
Heilmann RK, Kolodziejczak J, Bruccoleri AR, Gaskin JA, Schattenburg ML. Demonstration of resolving power λ/Δλ > 10,000 for a space-based x-ray transmission grating spectrometer. APPLIED OPTICS 2019; 58:1223-1238. [PMID: 30873991 DOI: 10.1364/ao.58.001223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 12/26/2018] [Indexed: 06/09/2023]
Abstract
We present measurements of the resolving power of a soft x-ray spectrometer consisting of 200 nm period lightweight, alignment-insensitive critical-angle transmission (CAT) gratings and a lightweight slumped-glass Wolter-I focusing mirror pair. We measure and model contributions from source, mirrors, detector pixel size, and grating period variation to the natural linewidth spectrum of the Al-K α 1 α 2 doublet. Measuring up to the 18th diffraction order, we consistently obtain small broadening due to gratings corresponding to a minimum effective grating resolving power Rg>10,000 with 90% confidence. Upper limits are often compatible with Rg=∞. Independent fitting of different diffraction orders, as well as ensemble fitting of multiple orders at multiple wavelengths, gives compatible results. Our data leads to uncertainties for the Al-Kα doublet linewidth and line separation parameters two to three times smaller than values found in the literature. Data from three different gratings are mutually compatible. This demonstrates that CAT gratings perform in excess of the requirements for the Arcus Explorer mission and are suitable for next-generation space-based x-ray spectrometer designs with resolving power five to 10 times higher than the transmission grating spectrometer onboard the Chandra X-ray Observatory.
Collapse
|
24
|
Amidani L, Plakhova TV, Romanchuk AY, Gerber E, Weiss S, Efimenko A, Sahle CJ, Butorin SM, Kalmykov SN, Kvashnina KO. Understanding the size effects on the electronic structure of ThO2 nanoparticles. Phys Chem Chem Phys 2019; 21:10635-10643. [DOI: 10.1039/c9cp01283d] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
High-resolution XANES spectra of small ThO2 nanoparticles show the signature of the more exposed Th atoms at the surface.
Collapse
Affiliation(s)
- Lucia Amidani
- The Rossendorf Beamline at ESRF – The European Synchrotron
- CS40220
- 38043 Grenoble Cedex 9
- France
- Helmholtz Zentrum Dresden-Rossendorf (HZDR)
| | - Tatiana V. Plakhova
- Department of Chemistry
- Lomonosov Moscow State University
- Moscow
- Russian Federation
| | - Anna Yu. Romanchuk
- Department of Chemistry
- Lomonosov Moscow State University
- Moscow
- Russian Federation
| | - Evgeny Gerber
- The Rossendorf Beamline at ESRF – The European Synchrotron
- CS40220
- 38043 Grenoble Cedex 9
- France
- Helmholtz Zentrum Dresden-Rossendorf (HZDR)
| | - Stephan Weiss
- Helmholtz Zentrum Dresden-Rossendorf (HZDR)
- Institute of Resource Ecology
- 01314 Dresden
- Germany
| | - Anna Efimenko
- ESRF – The European Synchrotron
- CS40220
- 38043 Grenoble Cedex 9
- France
| | | | - Sergei M. Butorin
- Molecular and Condensed Matter Physics
- Department of Physics and Astronomy
- Uppsala University
- Uppsala
- Sweden
| | - Stepan N. Kalmykov
- Department of Chemistry
- Lomonosov Moscow State University
- Moscow
- Russian Federation
| | - Kristina O. Kvashnina
- The Rossendorf Beamline at ESRF – The European Synchrotron
- CS40220
- 38043 Grenoble Cedex 9
- France
- Helmholtz Zentrum Dresden-Rossendorf (HZDR)
| |
Collapse
|
25
|
Jahrman EP, Holden WM, Ditter AS, Kozimor SA, Kihara SL, Seidler GT. Vacuum formed temporary spherically and toroidally bent crystal analyzers for x-ray absorption and x-ray emission spectroscopy. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:013106. [PMID: 30709184 DOI: 10.1063/1.5057231] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 12/17/2018] [Indexed: 06/09/2023]
Abstract
We demonstrate that vacuum forming of 10-cm diameter silicon wafers of various crystallographic orientations under an x-ray permeable, flexible window can easily generate spherically bent crystal analyzers and toroidally bent crystal analyzers with ∼1-eV energy resolution and a 1-m major radius of curvature. In applications at synchrotron light sources, x-ray free electron lasers, and laboratory spectrometers, these characteristics are generally sufficient for many x-ray absorption fine structure (XAFS), x-ray emission spectroscopy (XES), and resonant inelastic x-ray scattering applications in the chemical sciences. Unlike existing optics manufacturing methods using epoxy or anodic bonding, vacuum forming without adhesive is temporary in the sense that the bent wafer can be removed when vacuum is released and exchanged for a different orientation wafer. Therefore, the combination of an x-ray compatible vacuum-forming chamber, a library of thin wafers, and a small number of forms having different secondary curvatures can give extreme flexibility in spectrometer energy range. As proof of this method, we determine the energy resolution and reflectivity for several such vacuum-formed bent crystal analyzers in laboratory-based XAFS and XES studies using a conventional x-ray tube. For completeness, we also show x-ray images collected on the detector plane to characterize the resulting focal spots and optical aberrations.
Collapse
Affiliation(s)
- Evan P Jahrman
- Physics Department, University of Washington, Seattle, Washington 98195, USA
| | - William M Holden
- Physics Department, University of Washington, Seattle, Washington 98195, USA
| | - Alexander S Ditter
- Physics Department, University of Washington, Seattle, Washington 98195, USA
| | - Stosh A Kozimor
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - Scott L Kihara
- Physics Department, University of Washington, Seattle, Washington 98195, USA
| | - Gerald T Seidler
- Physics Department, University of Washington, Seattle, Washington 98195, USA
| |
Collapse
|
26
|
Revelli A, Moretti Sala M, Monaco G, Becker P, Bohatý L, Hermanns M, Koethe TC, Fröhlich T, Warzanowski P, Lorenz T, Streltsov SV, van Loosdrecht PHM, Khomskii DI, van den Brink J, Grüninger M. Resonant inelastic x-ray incarnation of Young's double-slit experiment. SCIENCE ADVANCES 2019; 5:eaav4020. [PMID: 30746479 PMCID: PMC6357738 DOI: 10.1126/sciadv.aav4020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Accepted: 12/14/2018] [Indexed: 06/09/2023]
Abstract
Young's archetypal double-slit experiment forms the basis for modern diffraction techniques: The elastic scattering of waves yields an interference pattern that captures the real-space structure. Here, we report on an inelastic incarnation of Young's experiment and demonstrate that resonant inelastic x-ray scattering (RIXS) measures interference patterns, which reveal the symmetry and character of electronic excited states in the same way as elastic scattering does for the ground state. A prototypical example is provided by the quasi-molecular electronic structure of insulating Ba3CeIr2O9 with structural Ir dimers and strong spin-orbit coupling. The double "slits" in this resonant experiment are the highly localized core levels of the two Ir atoms within a dimer. The clear double-slit-type sinusoidal interference patterns that we observe allow us to characterize the electronic excitations, demonstrating the power of RIXS interferometry to unravel the electronic structure of solids containing, e.g., dimers, trimers, ladders, or other superstructures.
Collapse
Affiliation(s)
- A. Revelli
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - M. Moretti Sala
- European Synchrotron Radiation Facility, BP 220, F-38043 Grenoble Cedex, France
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133 Milano, Italy
| | - G. Monaco
- Dipartimento di Fisica, Università di Trento, via Sommarive 14, 38123 Povo (TN), Italy
| | - P. Becker
- Abteilung Kristallographie, Institut für Geologie und Mineralogie, Zülpicher Strasse 49b, D-50674 Köln, Germany
| | - L. Bohatý
- Abteilung Kristallographie, Institut für Geologie und Mineralogie, Zülpicher Strasse 49b, D-50674 Köln, Germany
| | - M. Hermanns
- Institut für Theoretische Physik, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
- Department of Physics, University of Gothenburg, SE-412 96 Gothenburg, Sweden
- Department of Physics, Stockholm University, AlbaNova University Center, SE-106 91 Stockholm, Sweden
- Nordita, KTH Royal Institute of Technology and Stockholm University, Roslagstullsbacken 23, SE-106 91 Stockholm, Sweden
| | - T. C. Koethe
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - T. Fröhlich
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - P. Warzanowski
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - T. Lorenz
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - S. V. Streltsov
- M.N. Mikheev Institute of Metal Physics, Ural Branch, Russian Academy of Sciences, 620137 Ekaterinburg, Russia
- Ural Federal University, Mira Street 19, 620002 Ekaterinburg, Russia
| | - P. H. M. van Loosdrecht
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - D. I. Khomskii
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| | - J. van den Brink
- Institute for Theoretical Solid State Physics, IFW Dresden, Helmholtzstrasse 20, 01069 Dresden, Germany
| | - M. Grüninger
- II. Physikalisches Institut, Universität zu Köln, Zülpicher Strasse 77, D-50937 Köln, Germany
| |
Collapse
|
27
|
Ablett JM, Prieur D, Céolin D, Lassalle-Kaiser B, Lebert B, Sauvage M, Moreno T, Bac S, Balédent V, Ovono A, Morand M, Gélebart F, Shukla A, Rueff JP. The GALAXIES inelastic hard X-ray scattering end-station at Synchrotron SOLEIL. JOURNAL OF SYNCHROTRON RADIATION 2019; 26:263-271. [PMID: 30655494 DOI: 10.1107/s160057751801559x] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 11/03/2018] [Indexed: 06/09/2023]
Abstract
GALAXIES is an in-vacuum undulator hard X-ray micro-focused beamline dedicated to the study of the electronic structure of materials with high energy resolution using both photoelectron spectroscopy and inelastic X-ray scattering and under both non-resonant (NR-IXS) and resonant (RIXS) conditions. Due to the penetrating power of hard X-rays and the `photon-in/photon-out' technique, the sample environment is not a limitation. Materials under extreme conditions, for example in diamond anvil cells or catalysis chambers, thus constitute a major research direction. Here, the design and performance of the inelastic X-ray scattering end-station that operates in the energy range from ∼4 keV up to 12 keV is reported, and its capabilities are highlighted using a selection of data taken from recently performed experiments. The ability to scan `on the fly' the incident and scattered/emitted X-ray energies, and the sample position enables fast data collection and high experimental throughput. A diamond X-ray transmission phase retarder, which can be used to generate circularly polarized light, will also be discussed in the light of the recent RIXS-MCD approach.
Collapse
Affiliation(s)
- J M Ablett
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - D Prieur
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - D Céolin
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - B Lassalle-Kaiser
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - B Lebert
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - M Sauvage
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - Th Moreno
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - S Bac
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| | - V Balédent
- Laboratoire de Physique des Solides, 91400 Orsay, France
| | - A Ovono
- École Nationale Supérieure d'Ingénieurs de Limoges, France
| | - M Morand
- Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, Sorbonne Université, UMR CNRS 7590, MNHN, IRD UMR 206, 4 Place Jussieu, F-75005 Paris, France
| | - F Gélebart
- Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, Sorbonne Université, UMR CNRS 7590, MNHN, IRD UMR 206, 4 Place Jussieu, F-75005 Paris, France
| | - A Shukla
- Institut de Minéralogie, de Physique des Matériaux et de Cosmochimie, Sorbonne Université, UMR CNRS 7590, MNHN, IRD UMR 206, 4 Place Jussieu, F-75005 Paris, France
| | - J P Rueff
- Synchrotron SOLEIL, L'Orme des Merisiers, BP 48, Saint Aubin, 91192 Gif-sur-Yvette, France
| |
Collapse
|
28
|
Ni DD, Kang X, Yan S, Huang XC, Xiong T, Liang DX, Yang K, Zhu LF. A 1-m non-resonant inelastic x-ray scattering spectrometer at BL15U, Shanghai Synchrotron Radiation Facility. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:085108. [PMID: 30184690 DOI: 10.1063/1.5030032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 07/15/2018] [Indexed: 06/08/2023]
Abstract
We report the design, construction, and commissioning of a spectrometer for non-resonant inelastic x-ray scattering study installed at BL15U, Shanghai Synchrotron Radiation Facility. It features a 1-m vertical scattering arm. An energy resolution of 1.3 eV is achieved based on the 1 m Rowland circle and the diced Si(555) crystal analyzer with a fixed Bragg angle of about 88.8°. The inelastic squared form factors of 21S + 21P of helium with respect to the momentum transfer were measured and compared with the accurate and reliable theoretical calculations in order to verify the spectrometer. Furthermore, the spectrometer is designed to work in the momentum transfer region of 0 Å-1 < q < 8.68 Å-1 and to initially focus on the non-resonant inelastic x-ray scattering studies on gaseous samples.
Collapse
Affiliation(s)
- Dong-Dong Ni
- Hefei National Laboratory for Physical Sciences at Microscale and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Xu Kang
- Hefei National Laboratory for Physical Sciences at Microscale and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Shuai Yan
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
| | - Xin-Chao Huang
- Hefei National Laboratory for Physical Sciences at Microscale and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Tao Xiong
- Hefei National Laboratory for Physical Sciences at Microscale and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| | - Dong-Xu Liang
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
| | - Ke Yang
- Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201204, People's Republic of China
| | - Lin-Fan Zhu
- Hefei National Laboratory for Physical Sciences at Microscale and Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China
| |
Collapse
|
29
|
Vale JG, Calder S, Donnerer C, Pincini D, Shi YG, Tsujimoto Y, Yamaura K, Sala MM, van den Brink J, Christianson AD, McMorrow DF. Evolution of the Magnetic Excitations in NaOsO_{3} through its Metal-Insulator Transition. PHYSICAL REVIEW LETTERS 2018; 120:227203. [PMID: 29906188 DOI: 10.1103/physrevlett.120.227203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Indexed: 06/08/2023]
Abstract
The temperature dependence of the excitation spectrum in NaOsO_{3} through its metal-to-insulator transition (MIT) at 410 K has been investigated using resonant inelastic x-ray scattering at the Os L_{3} edge. High-resolution (ΔE∼56 meV) measurements show that the well-defined, low-energy magnons in the insulating state weaken and dampen upon approaching the metallic state. Concomitantly, a broad continuum of excitations develops which is well described by the magnetic fluctuations of a nearly antiferromagnetic Fermi liquid. By revealing the continuous evolution of the magnetic quasiparticle spectrum as it changes its character from itinerant to localized, our results provide unprecedented insight into the nature of the MIT in NaOsO_{3} [J. G. Vale, S. Calder, C. Donnerer, D. Pincini, Y. G. Shi, Y. Tsujimoto, K. Yamaura, M. M. Sala, J. van den Brink, A. D. Christianson, and D. F. McMorrow, Phys. Rev. B 97, 184429 (2018)PRBMDO2469-995010.1103/PhysRevB.97.184429].
Collapse
Affiliation(s)
- J G Vale
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, United Kingdom
- Laboratory for Quantum Magnetism, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne CH-1015, Switzerland
| | - S Calder
- Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA
| | - C Donnerer
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - D Pincini
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, United Kingdom
- Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom
| | - Y G Shi
- Beijing National Laboratory for Condensed Matter Physics and Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
| | - Y Tsujimoto
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
| | - K Yamaura
- Research Center for Functional Materials, National Institute for Materials Science, 1-1 Namiki, Tsukuba, Ibaraki 305-0044, Japan
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, North 10 West 8, Kita-ku, Sapporo, Hokkaido 060-0810, Japan
| | - M Moretti Sala
- ESRF, The European Synchrotron, 71 Avenue des Martyrs, 38043 Grenoble, France
| | - J van den Brink
- Institute for Theoretical Solid State Physics, IFW Dresden, D01171 Dresden, Germany
| | - A D Christianson
- Neutron Scattering Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA
- Department of Physics and Astronomy, University of Tennessee, Knoxville, Tennessee 37996, USA
| | - D F McMorrow
- London Centre for Nanotechnology and Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, United Kingdom
| |
Collapse
|