1
|
Navaeipour F, Hepburn MS, Li J, Metzner KL, Amos SE, Vahala D, Maher S, Choi YS, Kennedy BF. In situ stress estimation in quantitative micro-elastography. BIOMEDICAL OPTICS EXPRESS 2024; 15:3609-3626. [PMID: 38867802 PMCID: PMC11166433 DOI: 10.1364/boe.522002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 04/20/2024] [Accepted: 04/22/2024] [Indexed: 06/14/2024]
Abstract
In quantitative micro-elastography (QME), a pre-characterized compliant layer with a known stress-strain curve is utilized to map stress at the sample surface. However, differences in the boundary conditions of the compliant layer when it is mechanically characterized and when it is used in QME experiments lead to inconsistent stress estimation and consequently, inaccurate elasticity measurements. Here, we propose a novel in situ stress estimation method using an optical coherence tomography (OCT)-based uniaxial compression testing system integrated with the QME experimental setup. By combining OCT-measured axial strain with axial stress determined using a load cell in the QME experiments, we can estimate in situ stress for the compliant layer, more accurately considering its boundary conditions. Our proposed method shows improved accuracy, with an error below 10%, compared to 85% using the existing QME technique with no lubrication. Furthermore, demonstrations on hydrogels and cells indicate the potential of this approach for improving the characterization of the micro-scale mechanical properties of cells and their interactions with the surrounding biomaterial, which has potential for application in cell mechanobiology.
Collapse
Affiliation(s)
- Farzaneh Navaeipour
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia
- Department of Electrical, Electronic and Computer Engineering, School of Engineering, The University of Western Australia, 35, Stirling Highway, Perth, Western Australia 6009, Australia
| | - Matt S. Hepburn
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia
- Department of Electrical, Electronic and Computer Engineering, School of Engineering, The University of Western Australia, 35, Stirling Highway, Perth, Western Australia 6009, Australia
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziadzka 5, 87-100 Torun, Poland
| | - Jiayue Li
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia
- Department of Electrical, Electronic and Computer Engineering, School of Engineering, The University of Western Australia, 35, Stirling Highway, Perth, Western Australia 6009, Australia
- Australian Research Council Centre for Personalised Therapeutics Technologies, Australia
| | - Kai L. Metzner
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia
- Department of Electrical, Electronic and Computer Engineering, School of Engineering, The University of Western Australia, 35, Stirling Highway, Perth, Western Australia 6009, Australia
| | - Sebastian E. Amos
- School of Human Sciences, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia 6009, Australia
| | - Danielle Vahala
- School of Human Sciences, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia 6009, Australia
| | - Samuel Maher
- School of Human Sciences, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia 6009, Australia
| | - Yu Suk Choi
- School of Human Sciences, The University of Western Australia, 35 Stirling Highway, Perth, Western Australia 6009, Australia
| | - Brendan F. Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands and Centre for Medical Research, The University of Western Australia, Perth, Western Australia 6009, Australia
- Department of Electrical, Electronic and Computer Engineering, School of Engineering, The University of Western Australia, 35, Stirling Highway, Perth, Western Australia 6009, Australia
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziadzka 5, 87-100 Torun, Poland
- Australian Research Council Centre for Personalised Therapeutics Technologies, Australia
| |
Collapse
|
2
|
Bogusz P, Krasoń W, Pazur K. Application of Digital Image Correlation for Strain Mapping of Structural Elements and Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2577. [PMID: 38893841 PMCID: PMC11174112 DOI: 10.3390/ma17112577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/14/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024]
Abstract
The strain gauge method and the digital image correlation (DIC) method are commonly employed for measuring strain in tested objects, including material specimens and structural elements. The optical method enables the assessment of 3D strain fields across the entire area of interest, achieved through cameras and advanced software. The study investigates both quasi-static strength tests and more advanced research of structures. It explores full-scale construction testing, featuring highly stressed components of new wagon designs. The paper reviews the benefits and challenges of using the DIC method to measure large-scale elements. Conducting full-scale object testing is characterized by significant complexity, often involving interactions between elements, complex loading conditions, and the influence of friction. Numerous factors affect the measurements. Therefore, to compare both methods, an initially standard shear by tensile test of CFRP composite was analyzed. The analysis of strain maps provides valuable visualization of deformation patterns occurring during construction loading. The strain gauge method was crucial for verifying the quality of the DIC measurements. The results obtained provide a detailed understanding of how the components behave, highlighting the versatility of digital image correlation technology. For strain values of 0.3% and above, a good match was obtained between optical and strain gauge measurements. Below this value, the results have less accuracy. The results obtained provide a detailed understanding of how the components behave, highlighting the versatility of digital image correlation technology. The error comparison and discussion between different measurement scenarios were conducted. The paper presents a developed methodology for measuring strain and displacement state in complex and crucial structural elements. The method can be applied to measurements of heavily loaded components used in the transportation industry; for example, in railways.
Collapse
Affiliation(s)
- Paweł Bogusz
- Institute of Mechanics and Computational Engineering, Faculty of Mechanical Engineering, Military University of Technology, gen. Sylwestra Kaliskiego 2 Street, 00-908 Warsaw, Poland;
| | - Wiesław Krasoń
- Institute of Mechanics and Computational Engineering, Faculty of Mechanical Engineering, Military University of Technology, gen. Sylwestra Kaliskiego 2 Street, 00-908 Warsaw, Poland;
| | - Kamil Pazur
- Łukasiewicz Research Network—Institute of Aviation, al. Krakowska 110/114, 02-256 Warsaw, Poland;
| |
Collapse
|
3
|
Tucker SS, Giblin JT, Kiliç K, Chen A, Tang J, Boas DA. Optical coherence tomography-based design for a real-time motion corrected scanning microscope. OPTICS LETTERS 2023; 48:3805-3808. [PMID: 37450755 DOI: 10.1364/ol.490087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 06/27/2023] [Indexed: 07/18/2023]
Abstract
While two-photon fluorescence microscopy is a powerful platform for the study of functional dynamics in living cells and tissues, the bulk motion inherent to these applications causes distortions. We have designed a motion tracking module based on spectral domain optical coherence tomography which compliments a laser scanning two-photon microscope with real-time corrective feedback. The module can be added to fluorescent imaging microscopes using a single dichroic and without additional contrast agents. We demonstrate that the system can track lateral displacements as large as 10 μm at 5 Hz with latency under 14 ms and propose a scheme to extend the system to 3D correction with the addition of a remote focusing module. We also propose several ways to improve the module's performance by reducing the feedback latency. We anticipate that this design can be adapted to other imaging modalities, enabling the study of samples subject to motion artifacts at higher resolution.
Collapse
|
4
|
Mason JH, Luo L, Reinwald Y, Taffetani M, Hallas-Potts A, Herrington CS, Srsen V, Lin CJ, Barroso IA, Zhang Z, Zhang Z, Ghag AK, Yang Y, Waters S, El Haj AJ, Bagnaninchi PO. Debiased ambient vibrations optical coherence elastography to profile cell, organoid and tissue mechanical properties. Commun Biol 2023; 6:543. [PMID: 37202417 DOI: 10.1038/s42003-023-04788-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Accepted: 03/31/2023] [Indexed: 05/20/2023] Open
Abstract
The role of the mechanical environment in defining tissue function, development and growth has been shown to be fundamental. Assessment of the changes in stiffness of tissue matrices at multiple scales has relied mostly on invasive and often specialist equipment such as AFM or mechanical testing devices poorly suited to the cell culture workflow.In this paper, we have developed a unbiased passive optical coherence elastography method, exploiting ambient vibrations in the sample that enables real-time noninvasive quantitative profiling of cells and tissues. We demonstrate a robust method that decouples optical scattering and mechanical properties by actively compensating for scattering associated noise bias and reducing variance. The efficiency for the method to retrieve ground truth is validated in silico and in vitro, and exemplified for key applications such as time course mechanical profiling of bone and cartilage spheroids, tissue engineering cancer models, tissue repair models and single cell. Our method is readily implementable with any commercial optical coherence tomography system without any hardware modifications, and thus offers a breakthrough in on-line tissue mechanical assessment of spatial mechanical properties for organoids, soft tissues and tissue engineering.
Collapse
Affiliation(s)
- Jonathan H Mason
- MRC Centre for Regenerative Medicine, The University of Edinburgh, Edinburgh, UK
| | - Lu Luo
- Healthcare Technology Institute, University of Birmingham, Birmingham, UK
| | - Yvonne Reinwald
- Department of Engineering, Nottingham Trent University, Nottingham, UK
| | | | - Amelia Hallas-Potts
- MRC Centre for Regenerative Medicine, The University of Edinburgh, Edinburgh, UK
- Cancer Research UK Edinburgh Centre, The University of Edinburgh, Edinburgh, UK
| | - C Simon Herrington
- Cancer Research UK Edinburgh Centre, The University of Edinburgh, Edinburgh, UK
| | - Vlastimil Srsen
- MRC Centre for Regenerative Medicine, The University of Edinburgh, Edinburgh, UK
| | - Chih-Jen Lin
- MRC Centre for Reproductive Health, The Univeristy of Edinburgh, Edinburgh, UK
| | - Inês A Barroso
- School of Chemical Engineering, University of Birmingham, Birmingham, UK
| | - Zhihua Zhang
- School of Chemical Engineering, University of Birmingham, Birmingham, UK
| | - Zhibing Zhang
- School of Chemical Engineering, University of Birmingham, Birmingham, UK
| | - Anita K Ghag
- School of Chemical Engineering, University of Birmingham, Birmingham, UK
| | - Ying Yang
- Institute of Science and Technology in Medicine, Keele University, Stoke-on-Trent, UK
| | - Sarah Waters
- Mathematical Institute, University of Oxford, Oxford, UK
| | - Alicia J El Haj
- Healthcare Technology Institute, University of Birmingham, Birmingham, UK.
| | - Pierre O Bagnaninchi
- MRC Centre for Regenerative Medicine, The University of Edinburgh, Edinburgh, UK.
| |
Collapse
|
5
|
Lan G, Twa MD, Song C, Feng J, Huang Y, Xu J, Qin J, An L, Wei X. In vivo corneal elastography: A topical review of challenges and opportunities. Comput Struct Biotechnol J 2023; 21:2664-2687. [PMID: 37181662 PMCID: PMC10173410 DOI: 10.1016/j.csbj.2023.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 04/07/2023] [Accepted: 04/12/2023] [Indexed: 05/16/2023] Open
Abstract
Clinical measurement of corneal biomechanics can aid in the early diagnosis, progression tracking, and treatment evaluation of ocular diseases. Over the past two decades, interdisciplinary collaborations between investigators in optical engineering, analytical biomechanical modeling, and clinical research has expanded our knowledge of corneal biomechanics. These advances have led to innovations in testing methods (ex vivo, and recently, in vivo) across multiple spatial and strain scales. However, in vivo measurement of corneal biomechanics remains a long-standing challenge and is currently an active area of research. Here, we review the existing and emerging approaches for in vivo corneal biomechanics evaluation, which include corneal applanation methods, such as ocular response analyzer (ORA) and corneal visualization Scheimpflug technology (Corvis ST), Brillouin microscopy, and elastography methods, and the emerging field of optical coherence elastography (OCE). We describe the fundamental concepts, analytical methods, and current clinical status for each of these methods. Finally, we discuss open questions for the current state of in vivo biomechanics assessment techniques and requirements for wider use that will further broaden our understanding of corneal biomechanics for the detection and management of ocular diseases, and improve the safety and efficacy of future clinical practice.
Collapse
Affiliation(s)
- Gongpu Lan
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Michael D Twa
- College of Optometry, University of Houston, Houston, TX 77204, United States
| | - Chengjin Song
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
| | - JinPing Feng
- Institute of Engineering and Technology, Hubei University of Science and Technology, Xianning, Hubei 437100, China
| | - Yanping Huang
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Jingjiang Xu
- Guangdong-Hong Kong-Macao Intelligent Micro-Nano Optoelectronic Technology Joint Laboratory, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China
- Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Jia Qin
- Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Lin An
- Weiren Meditech Co., Ltd., Foshan, Guangdong 528000, China
| | - Xunbin Wei
- Biomedical Engineering Department, Peking University, Beijing 100081, China
- International Cancer Institute, Peking University, Beijing 100191, China
- Institute of Medical Technology, Peking University Health Science Center, Beijing 100191, China
| |
Collapse
|
6
|
Alexandrovskaya Y, Baum O, Sovetsky A, Matveyev A, Matveev L, Sobol E, Zaitsev V. Optical Coherence Elastography as a Tool for Studying Deformations in Biomaterials: Spatially-Resolved Osmotic Strain Dynamics in Cartilaginous Samples. MATERIALS (BASEL, SWITZERLAND) 2022; 15:904. [PMID: 35160851 PMCID: PMC8838169 DOI: 10.3390/ma15030904] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 01/14/2022] [Accepted: 01/20/2022] [Indexed: 12/15/2022]
Abstract
This paper presents a recently developed variant of phase-resolved Optical Coherence Elastography (OCE) enabling non-contact visualization of transient local strains of various origins in biological tissues and other materials. In this work, we demonstrate the possibilities of this new technique for studying dynamics of osmotically-induced strains in cartilaginous tissue impregnated with optical clearing agents (OCA). For poroelastic water-containing biological tissues, application of non-isotonic OCAs, various contrast additives, as well as drug solutions administration, may excite transient spatially-inhomogeneous strain fields of high magnitude in the tissue bulk, initiating mechanical and structural alterations. The range of the strain reliably observed by OCE varied from ±10-3 to ±0.4 for diluted and pure glycerol, correspondingly. The OCE-technique used made it possible to reveal previously inaccessible details of the complex spatio-temporal evolution of alternating-sign osmotic strains at the initial stages of agent diffusion. Qualitatively different effects produced by particular hydrophilic OCAs, such as glycerol and iohexol, are discussed, as well as concentration-dependent differences. Overall, the work demonstrates the unique abilities of the new OCE-modality in providing a deeper insight in real-time kinetics of osmotically-induced strains relevant to a broad range of biomedical applications.
Collapse
Affiliation(s)
- Yulia Alexandrovskaya
- Institute of Photon Technologies, Federal Scientific Research Center “Crystallography and Photonics”, Russian Academy of Sciences, 2 Pionerskaya Street, Troitsk, 108840 Moscow, Russia;
| | - Olga Baum
- Institute of Photon Technologies, Federal Scientific Research Center “Crystallography and Photonics”, Russian Academy of Sciences, 2 Pionerskaya Street, Troitsk, 108840 Moscow, Russia;
| | - Alexander Sovetsky
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Alexander Matveyev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Lev Matveev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| | - Emil Sobol
- UCI Health Beckman Laser Institute & Medical Clinic, 1002 Health Sciences Rd., Irvine, CA 92612, USA;
| | - Vladimir Zaitsev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova Street, 603950 Nizhny Novgorod, Russia; (A.S.); (A.M.); (L.M.); (V.Z.)
| |
Collapse
|
7
|
Kubelick KP, Mehrmohammadi M. Magnetic particles in motion: magneto-motive imaging and sensing. Theranostics 2022; 12:1783-1799. [PMID: 35198073 PMCID: PMC8825589 DOI: 10.7150/thno.54056] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Accepted: 11/22/2021] [Indexed: 11/05/2022] Open
Abstract
Superparamagnetic nanoparticles have become an important tool in biomedicine. Their biocompatibility, controllable small size, and magnetic properties allow manipulation with an external magnetic field for a variety of diagnostic and therapeutic applications. Recently, the magnetically-induced motion of superparamagnetic nanoparticles has been investigated as a new source of imaging contrast. In magneto-motive imaging, an external, time-varying magnetic field is applied to move a magnetically labeled subject, such as labeled cells or tissue. Several major imaging modalities such as ultrasound, photoacoustic imaging, optical coherence tomography, and laser speckle tracking can utilize magneto-motive contrast to monitor biological events at smaller scales with enhanced contrast and sensitivity. In this review article, an overview of magneto-motive imaging techniques is presented, including synthesis of superparamagnetic nanoparticles, fundamental principles of magneto-motive force and its utility to excite labeled tissue within a viscoelastic medium, current capabilities of magneto-motive imaging modalities, and a discussion of the challenges and future outlook in the magneto-motive imaging domain.
Collapse
Affiliation(s)
- Kelsey P. Kubelick
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University School of Medicine, Georgia, USA
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Georgia, USA
| | - Mohammad Mehrmohammadi
- Department of Biomedical Engineering, Wayne State University, Michigan, USA
- Barbara Ann Karmanos Cancer Institute, Michigan, USA
| |
Collapse
|
8
|
Real-Time Strain and Elasticity Imaging in Phase-Sensitive Optical Coherence Elastography Using a Computationally Efficient Realization of the Vector Method. PHOTONICS 2021. [DOI: 10.3390/photonics8120527] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
We present a real-time realization of OCT-based elastographic mapping local strains and distribution of the Young’s modulus in biological tissues, which is in high demand for biomedical usage. The described variant exploits the principle of Compression Optical Coherence Elastography (C-OCE) and uses processing of phase-sensitive OCT signals. The strain is estimated by finding local axial gradients of interframe phase variations. Instead of the popular least-squares method for finding these gradients, we use the vector approach, one of its advantages being increased computational efficiency. Here, we present a modified, especially fast variant of this approach. In contrast to conventional correlation-based methods and previously used phase-resolved methods, the described method does not use any search operations or local calculations over a sliding window. Rather, it obtains local strain maps (and then elasticity maps) using several transformations represented as matrix operations applied to entire complex-valued OCT scans. We first elucidate the difference of the proposed method from the previously used correlational and phase-resolved methods and then describe the proposed method realization in a medical OCT device, in which for real-time processing, a “typical” central processor (e.g., Intel Core i7-8850H) is sufficient. Representative examples of on-flight obtained elastographic images are given. These results open prospects for broad use of affordable OCT devices for high-resolution elastographic vitalization in numerous biomedical applications, including the use in clinic.
Collapse
|
9
|
Bai Y, Cai S, Xie S, Dong B. Adaptive incremental method for strain estimation in phase-sensitive optical coherence elastography. OPTICS EXPRESS 2021; 29:25327-25336. [PMID: 34614865 DOI: 10.1364/oe.433245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
We proposed an adaptive incremental method for the cumulative strain estimation in phase-sensitive optical coherence elastography. The method firstly counts the amount of phase noise points by mapping a binary noise map. After the noise threshold value is preset, the interframe interval is adaptively adjusted in terms of the phase noise ratio. Finally, the efficient estimation of cumulative strain is implemented by reducing the cumulative number. Since the level of phase noise is related to the different strain rates in accordance with the speckle decorrelation, the proposed method can estimate the large strains with high computation efficiency as well as signal-to-noise ratio (SNR) enhancement in nonlinear change of sample deformations. Real experiments of visualizing polymerization shrinkage with nonlinear change of deformations were performed to prove the superiority of adaptive incremental method in estimating the large strains. The proposed method expands the practicability of the incremental method in more complex scenes.
Collapse
|
10
|
De la Torre I MH, Frausto-Rea GDR, Mendoza-Santoyo F, Del S Hernandez Montes M. Fish swim water bulk displacement visualization with digital holographic interferometry. APPLIED OPTICS 2021; 60:5376-5381. [PMID: 34263775 DOI: 10.1364/ao.425059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/24/2021] [Indexed: 06/13/2023]
Abstract
A collimated transmission beam interferometer is used to measure the water motion provoked by the fish swimming through it. An indirect measurement of the fish motion impact in the water contained in a home-type aquarium is detected. Measurements of the whole aquarium are possible due to a large diameter collimated laser beam in the interferometer's object arm. This beam goes through the aquarium, and any perturbation inside it deflects the collimated beam. The interferometer detects a phase difference, i.e., the beam through the disturbed water undergoes different optical paths. This optical phase change was first demonstrated by means of a simple test using spherical steel marbles placed in a cuvette. For this, the small water movements for a single steel marble are detected with the acquired optical phase. Next, the aquarium optical phase results show water movements according to the fishes' size and swimming speed. It is worth mentioning that no additives were added to the aquarium's fresh water during the tests, so the water was crystal clear.
Collapse
|
11
|
Zaitsev VY, Matveyev AL, Matveev LA, Sovetsky AA, Hepburn MS, Mowla A, Kennedy BF. Strain and elasticity imaging in compression optical coherence elastography: The two-decade perspective and recent advances. JOURNAL OF BIOPHOTONICS 2021; 14:e202000257. [PMID: 32749033 DOI: 10.1002/jbio.202000257] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 07/28/2020] [Accepted: 07/29/2020] [Indexed: 05/20/2023]
Abstract
Quantitative mapping of deformation and elasticity in optical coherence tomography has attracted much attention of researchers during the last two decades. However, despite intense effort it took ~15 years to demonstrate optical coherence elastography (OCE) as a practically useful technique. Similarly to medical ultrasound, where elastography was first realized using the quasi-static compression principle and later shear-wave-based systems were developed, in OCE these two approaches also developed in parallel. However, although the compression OCE (C-OCE) was proposed historically earlier in the seminal paper by J. Schmitt in 1998, breakthroughs in quantitative mapping of genuine local strains and the Young's modulus in C-OCE have been reported only recently and have not yet obtained sufficient attention in reviews. In this overview, we focus on underlying principles of C-OCE; discuss various practical challenges in its realization and present examples of biomedical applications of C-OCE. The figure demonstrates OCE-visualization of complex transient strains in a corneal sample heated by an infrared laser beam.
Collapse
Affiliation(s)
- Vladimir Y Zaitsev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander L Matveyev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Lev A Matveev
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Alexander A Sovetsky
- Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod, Russia
| | - Matt S Hepburn
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| | - Alireza Mowla
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| | - Brendan F Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, Nedlands, Western Australia, 6009, Australia and Centre for Medical Research, The University of Western Australia, Crawley, Western Australia, Australia
- Department of Electrical, Electronic & Computer Engineering, School of Engineering, The University of Western Australia, Perth, Western Australia, Australia
| |
Collapse
|
12
|
Bersi MR, Acosta Santamaría VA, Marback K, Di Achille P, Phillips EH, Goergen CJ, Humphrey JD, Avril S. Multimodality Imaging-Based Characterization of Regional Material Properties in a Murine Model of Aortic Dissection. Sci Rep 2020; 10:9244. [PMID: 32514185 PMCID: PMC7280301 DOI: 10.1038/s41598-020-65624-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Accepted: 05/04/2020] [Indexed: 01/21/2023] Open
Abstract
Chronic infusion of angiotensin-II in atheroprone (ApoE-/-) mice provides a reproducible model of dissection in the suprarenal abdominal aorta, often with a false lumen and intramural thrombus that thickens the wall. Such lesions exhibit complex morphologies, with different regions characterized by localized changes in wall composition, microstructure, and properties. We sought to quantify the multiaxial mechanical properties of murine dissecting aneurysm samples by combining in vitro extension-distension data with full-field multimodality measurements of wall strain and thickness to inform an inverse material characterization using the virtual fields method. A key advance is the use of a digital volume correlation approach that allows for characterization of properties not only along and around the lesion, but also across its wall. Specifically, deformations are measured at the adventitial surface by tracking motions of a speckle pattern using a custom panoramic digital image correlation technique while deformations throughout the wall and thrombus are inferred from optical coherence tomography. These measurements are registered and combined in 3D to reconstruct the reference geometry and compute the 3D finite strain fields in response to pressurization. Results reveal dramatic regional variations in material stiffness and strain energy, which reflect local changes in constituent area fractions obtained from histology but emphasize the complexity of lesion morphology and damage within the dissected wall. This is the first point-wise biomechanical characterization of such complex, heterogeneous arterial segments. Because matrix remodeling is critical to the formation and growth of these lesions, we submit that quantification of regional material properties will increase the understanding of pathological mechanical mechanisms underlying aortic dissection.
Collapse
Affiliation(s)
- Matthew R Bersi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | | | - Karl Marback
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Paolo Di Achille
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Evan H Phillips
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Craig J Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA
| | - Stéphane Avril
- Mines Saint-Etienne, University of Lyon, University Jean Monnet, INSERM, Saint-Etienne, France.
| |
Collapse
|
13
|
Wang P, Chen Z, Xing D. Multi-parameter characterization of atherosclerotic plaques based on optical coherence tomography, photoacoustic and viscoelasticity imaging. OPTICS EXPRESS 2020; 28:13761-13774. [PMID: 32403844 DOI: 10.1364/oe.390874] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 04/11/2020] [Indexed: 06/11/2023]
Abstract
Detection of atherosclerotic plaque vulnerability is the critical step in prevention of acute coronary events. Fibrous cap thickness, lipid core size, and inflammation extent are three key parameters for assessing plaque vulnerability. Here, we report on multimodality imaging of mice aortic plaques using a system that integrates optical coherence tomography (OCT), photoacoustic imaging (PAI), and photoacoustic viscoelasticity imaging (PAVEI). The thickness of fibrous cap is accurately evaluated by OCT, and PAI helps to determine the distribution and size of lipid core. The mechanical properties of plaques are closely related to the plaque compositions and the content and distribution of macrophages, while PAVEI can characterize the plaque viscoelasticity through the phase delay of photoacoustic signal. Experimental results demonstrate that the OCT-PAI-PAVEI system can comprehensively characterize the three traits of atherosclerotic plaques, thereby identifying high-risk lesions.
Collapse
|
14
|
Lan G, Gu B, Larin KV, Twa MD. Clinical Corneal Optical Coherence Elastography Measurement Precision: Effect of Heartbeat and Respiration. Transl Vis Sci Technol 2020; 9:3. [PMID: 32821475 PMCID: PMC7401940 DOI: 10.1167/tvst.9.5.3] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 11/30/2019] [Indexed: 01/29/2023] Open
Abstract
Purpose Normal physiological movements (e.g., respiration and heartbeat) induce eye motions during clinical measurements of human corneal biomechanical properties using optical coherence elastography (OCE). We quantified the effects of respiratory and cardiac-induced eye motions on clinical corneal OCE measurement precision and repeatability. Methods Corneal OCE was performed using low-force, micro-air-pulse tissue stimulation and high-resolution phase-sensitive optical coherence tomography (OCT) imaging. Axial surface displacements of the corneal apex were measured (M-mode) at a 70-kHz sampling rate and three different stimulation pressures (20-60 Pa). Simultaneously, the axial corneal position was tracked with structural OCT imaging, while the heartrate and respiration were monitored over a 90 second period. Results Respiratory- and cardiac-induced eye motions have distinctly lower frequency (0.1-1 Hz) and much greater amplitude (up to ± 50 µm movements) than air-pulse-induced corneal tissue deformations (∼250 Hz, <1 µm). The corneal displacements induced during OCE measurements in vivo were -0.41 ± 0.06 µm (n = 22 measurements, coefficient of variation [CV]: 14.6%) and -0.44 ± 0.07 µm (n = 50 measurements, CV: 15.9%), respectively, from two human subjects at 40 Pa stimulation pressure. Observed variation in corneal tissue displacements were not associated with tissue stimulation magnitude, or the amplitude of physiologically induced axial eye motion. Conclusions The microsecond timescale and submicron tissue displacements observed during corneal OCE measurements are separable from normal involuntary physiological movements, such as the oculocardiac pulse and respiratory movements. Translational Relevance This work advances innovations in biomedical imaging and engineering for clinical diagnostic applications for soft-tissue biomechanical testing.
Collapse
Affiliation(s)
- Gongpu Lan
- Department of Photoelectric Technology, Foshan University, Foshan, Guangdong, China.,School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Boyu Gu
- Department of Ophthalmology, Doheny Eye Institute, University of California -Los Angeles, Los Angeles, CA, USA
| | - Kirill V Larin
- Department of Biomedical Engineering, University of Houston, Houston, TX, USA
| | - Michael D Twa
- School of Optometry, University of Alabama at Birmingham, Birmingham, AL, USA.,College of Optometry, University of Houston, Houston, TX, USA
| |
Collapse
|
15
|
Jeong MR, Lee IS, Shin YB, Song YS, Park S, Song JW, Moon JI. Clinical Efficacy of Real-Time Sonoelastography for the Follow-Up of Congenital Sternocleidomastoid Muscle Torticollis. JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY 2020; 81:176-189. [PMID: 36238111 PMCID: PMC9432086 DOI: 10.3348/jksr.2020.81.1.176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 07/26/2019] [Accepted: 07/31/2019] [Indexed: 11/15/2022]
Abstract
Purpose To evaluate the clinical efficacy of real-time sonoelastography (RTS) for the follow-up of congenital muscular torticollis, based on measurements of muscle elasticity. Materials and Methods Thirty-four infants (23 male, 11 female) with congenital sternocleidomastoid (SCM) muscle torticollis underwent ultrasonography and elastography between November 2012 and December 2014. We evaluated the thickness, morphology (mass-like, fusiform, or overall thickened shape), and echogenicity of the SCM muscle on grayscale images and color patterns (homogeneous blue, mixed green < 50% and ≥ 50%, and green to red) on elastography. Strain ratios were measured using Q-lab software. A clinician classified the degree of neck rotation and side flexion deficits using a 5-point grade system based on angles of neck rotation and side flexion. Correlations between the ultrasonography and clinical findings were evaluated by statistical analysis. Results Twenty-two infants had right and 12 had left SCM torticollis, respectively. Linear regression analysis showed that involved/contralateral SCM thickness differences, morphology, elasticity color scores, and strain ratios of the affected SCM muscles were significantly correlated with neck rotation and side flexion deficit scores (p < 0.05). The elasticity color score of the affected SCM muscle was the most significant factor. Conclusion RTS might provide a reliable means for evaluating and monitoring congenital muscular torticollis.
Collapse
Affiliation(s)
- Mi ri Jeong
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - In Sook Lee
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - Yong Beom Shin
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
- Department of Rehabilitation, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
| | - You Seon Song
- Department of Radiology, Pusan National University Hospital, Biomedical Research Institute, Busan, Korea
- Department of Radiology, Pusan National University School of Medicine, Busan, Korea
| | - Sekyoung Park
- Department of Radiology, Kosin University Gospel Hospital, Busan, Korea
| | - Jong Woon Song
- Department of Radiology, Inje University Haeundae Paik Hospital, Busan, Korea
| | - Jin Il Moon
- Department of Radiology, Gyeongsang National University Changwon Hospital, Changwon, Korea
| |
Collapse
|
16
|
Meng F, Chen C, Hui S, Wang J, Feng Y, Sun C. Three-dimensional static optical coherence elastography based on inverse compositional Gauss-Newton digital volume correlation. JOURNAL OF BIOPHOTONICS 2019; 12:e201800422. [PMID: 31008547 DOI: 10.1002/jbio.201800422] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Revised: 04/16/2019] [Accepted: 04/18/2019] [Indexed: 06/09/2023]
Abstract
The three-dimensional (3D) mechanical properties characterization of tissue is essential for physiological and pathological studies, as biological tissue is mostly heterogeneous and anisotropic. A digital volume correlation (DVC)-based 3D optical coherence elastography (OCE) method is developed to measure the 3D displacement and strain tensors. The DVC algorithm includes a zero-mean normalized cross-correlation criterion-based coarse search regime, an inverse compositional Gauss-Newton fine search algorithm and a local ternary quadratic polynomial fitting strain calculation method. A 3D optical coherence tomography (OCT) scanning protocol is proposed through theoretical analysis and experimental verification. Measurement errors of the DVC-based 3D OCE method are evaluated to be less than 2.0 μm for displacements and 0.30% for strains by rigid body motion experiments. The 3D displacements and strains of a phantom and a specimen of chicken breast tissue under compression are measured. Results of the phantom show a good agreement with theoretical analysis and tensile testing. The strains of the chicken breast tissue indicate anisotropic biomechanical properties. This study provides an effective method for 3D biomechanical property studies of soft tissue and improves the development of 3D OCE techniques.
Collapse
Affiliation(s)
- Fanchao Meng
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| | - Cheng Chen
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| | - Shun Hui
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| | - Jingbo Wang
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| | - Yvlong Feng
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| | - Cuiru Sun
- Department of Mechanical Engineering, Tianjin Key Laboratory of Modern Engineering Mechanics, Tianjin University, Tianjin, China
| |
Collapse
|
17
|
Singh MS, Thomas A. Photoacoustic elastography imaging: a review. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-15. [PMID: 31041859 PMCID: PMC6990059 DOI: 10.1117/1.jbo.24.4.040902] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2018] [Accepted: 04/05/2019] [Indexed: 05/12/2023]
Abstract
Elastography imaging is a promising tool-in both research and clinical settings-for diagnosis, staging, and therapeutic treatments of various life-threatening diseases (including brain tumors, breast cancers, prostate cancers, and Alzheimer's disease). Large variation in the physical (elastic) properties of tissue, from normal to diseased stages, enables highly sensitive characterization of pathophysiological states of the diseases. On the other hand, over the last decade or so, photoacoustic (PA) imaging-an imaging modality that combines the advantageous features of two separate imaging modalities, i.e., high spatial resolution and high contrast obtainable, respectively, from ultrasound- and optical-based modalities-has been emerging and widely studied. Recently, recovery of elastic properties of soft biological tissues-in addition to prior reported recovery of vital tissue physiological information (Hb, HbO2, SO, and total Hb), noninvasively and nondestructively, with unprecedented spatial resolution (μm) at penetration depth (cm)-has been reported. Studies demonstrating that combined recovery of mechanical tissue properties and physiological information-by a single (PA) imaging unit-pave a promising platform in clinical diagnosis and therapeutic treatments. We offer a comprehensive review of PA imaging technology, focusing on recent advances in relation to elastography. Our review draws out technological challenges pertaining to PA elastography (PAE) imaging, and viable approaches. Currently, PAE imaging is in the nurture stage of its development, where the technology is limited to qualitative study. The prevailing challenges (specifically, quantitative measurements) may be addressed in a similar way by which ultrasound elastography and optical coherence elastography were accredited for quantitative measurements.
Collapse
Affiliation(s)
- Mayanglambam Suheshkumar Singh
- Indian Institute of Science Education and Research Thiruvananthapuram (IISER-TVM), School of Physics (SoP), Biomedical Instrumentation and Imaging Laboratory (BIIL), Thiruvananthapuram, Kerala, India
| | - Anjali Thomas
- Indian Institute of Science Education and Research Thiruvananthapuram (IISER-TVM), School of Physics (SoP), Biomedical Instrumentation and Imaging Laboratory (BIIL), Thiruvananthapuram, Kerala, India
| |
Collapse
|
18
|
3D Strain and Elasticity Measurement of Layered Biomaterials by Optical Coherence Elastography based on Digital Volume Correlation and Virtual Fields Method. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9071349] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The three-dimensional (3D) mechanical property characterization of biological tissues is essential for physiological and pathological studies. A digital volume correlation (DVC) and virtual fields method (VFM) based 3D optical coherence elastography (OCE) method is developed to quantitatively measure the 3D full-field displacements, strains and elastic parameters of layered biomaterials assuming the isotropy and homogeneity of each layer. The integrated noise-insensitive DVC method can obtain the 3D strain tensor with an accuracy of 10%. Automatic segmentation of the layered materials is realized based on the full field strain and strain gradient. With the strain tensor as input, and in combination with the segmented geometry, the Young’s modulus and Poison’s ratio of each layer of a double-layered material and a pork specimen are obtained by the VFM. This study provides a powerful experimental method for the differentiation of various components of heterogeneous biomaterials, and for the measurement of biomechanics.
Collapse
|
19
|
Spahr H, Pfäffle C, Hüttmann G, Hillmann D. Artifacts in speckle tracking and multi-aperture Doppler OCT imaging of lateral motion. OPTICS LETTERS 2019; 44:1315-1318. [PMID: 30874639 DOI: 10.1364/ol.44.001315] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 01/29/2019] [Indexed: 06/09/2023]
Abstract
In optical coherence tomography (OCT), lateral motion is determined either by speckle tracking or by multi-aperture Doppler OCT. Here we show that both methods may provide incorrect results because, outside the focal plane, non-uniform axial motion is misinterpreted as lateral motion. First, we demonstrate the existence of this artifact by means of a simulation for speckle tracking. Then the physical origin of the artifact and its mathematical relation to defocus and axial motion are explained. It is shown that speckle tracking and multi-aperture Doppler OCT are equally affected by the artifact, which has a considerable effect, even for a defocus of less than one Rayleigh length.
Collapse
|
20
|
Lan G, Twa MD. Theory and design of Schwarzschild scan objective for Optical Coherence Tomography. OPTICS EXPRESS 2019; 27:5048-5064. [PMID: 30876110 PMCID: PMC6410919 DOI: 10.1364/oe.27.005048] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Optical coherence elastography (OCE) is one form of multi-channel imaging that combines high-resolution optical coherence tomography (OCT) imaging with mechanical tissue stimulation. This combination of structural and functional imaging can require additional space to integrate imaging capabilities with additional functional elements (e.g., optical, mechanical, or acoustic modulators) either at or near the imaging axis. We address this challenge by designing a novel scan lens based on a modified Schwarzchild objective lens, comprised of a pair of concentric mirrors with potential space to incorporate additional functional elements and minimal compromise to the available scan field. This scan objective design allows perpendicular tissue-excitation and response recording. The optimized scan lens design results in a working distance that is extended to ~140 mm (nearly 2x the focal length), an expanded central space suitable for additional functional elements (>15 mm in diameter) and diffraction-limited lateral resolution (19.33 μm) across a full annular scan field ~ ± 7.5 mm to ± 12.7 mm.
Collapse
Affiliation(s)
- Gongpu Lan
- Foshan University, Department of Photoelectric Technology, Foshan, Guangdong 528000, China
- University of Alabama at Birmingham, School of Optometry, Birmingham, Alabama 35294, USA
| | - Michael D. Twa
- University of Alabama at Birmingham, School of Optometry, Birmingham, Alabama 35294, USA
| |
Collapse
|
21
|
Li E, Makita S, Azuma S, Miyazawa A, Yasuno Y. Compression optical coherence elastography with two-dimensional displacement measurement and local deformation visualization. OPTICS LETTERS 2019; 44:787-790. [PMID: 30767987 DOI: 10.1364/ol.44.000787] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Accepted: 01/07/2019] [Indexed: 05/22/2023]
Abstract
Current compression-based optical coherence elastography (OCE) only measures the axial displacement of a tissue, although the tissue also undergoes lateral displacement and microstructural alteration by the compression. In this Letter, we demonstrate a new compression-based OCE method that visualizes not only axial displacement, but also lateral displacement and microstructural decorrelation (MSD). This method employs complex correlation-based displacement and MSD measurements. It is implemented in a swept-source optical coherence tomography system with an active submicrometer compression. The performance of the method was demonstrated by measuring the porcine carotid artery and esophagus. The results showed significant axial and lateral displacements in the tissues by compression. An MSD map demonstrates high-contrast mechanical-property imaging.
Collapse
|
22
|
Zhou K, Le N, Huang Z, Li C. High-intensity-focused ultrasound and phase-sensitive optical coherence tomography for high resolution surface acoustic wave elastography. JOURNAL OF BIOPHOTONICS 2018; 11. [PMID: 28700131 DOI: 10.1002/jbio.201700051] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Revised: 06/27/2017] [Accepted: 06/29/2017] [Indexed: 05/04/2023]
Abstract
Elastography has the ability of quantitatively evaluating the mechanical properties of soft tissue; thus it is helpful for diagnosis and treatment monitoring of many diseases, for example, skin diseases. Surface acoustic waves (SAWs) have been proven to be a non-invasive, non-destructive method for accurate characterization of tissue elastic properties. Current SAW elastography using high-energy laser pulse or mechanical shaker still have some problems. In order to improve SAW elastography in medical application, a new technique was proposed in this paper, which combines high-intensity-focused ultrasound as a SAWs impulse inducer and phase-sensitive optical coherence tomography as a SAWs detector. A 2% agar-agar phantom and ex-vivo porcine skin were tested. The data were processed by a new algorithm based on the Fourier analysis. The results show that the proposed method has the capability of quantifying the elastic properties of soft tissue-mimicking materials. The lateral resolution of the elastogram has been significantly improved and the different layers in heterogeneous material could also been distinguished. Our improved technique of SAW elastography has a large potential to be widely applied in clinical use for skin disease diagnosis and treatment monitoring.
Collapse
Affiliation(s)
- Kanheng Zhou
- School of Science and Engineering, University of Dundee, Dundee, UK
| | - Nhan Le
- School of Science and Engineering, University of Dundee, Dundee, UK
| | - Zhihong Huang
- School of Science and Engineering, University of Dundee, Dundee, UK
| | - Chunhui Li
- School of Science and Engineering, University of Dundee, Dundee, UK
| |
Collapse
|
23
|
Tsai TH, Leggett CL, Trindade AJ, Sethi A, Swager AF, Joshi V, Bergman JJ, Mashimo H, Nishioka NS, Namati E. Optical coherence tomography in gastroenterology: a review and future outlook. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-17. [PMID: 29260538 DOI: 10.1117/1.jbo.22.12.121716] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/05/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence tomography (OCT) is an imaging technique optically analogous to ultrasound that can generate depth-resolved images with micrometer-scale resolution. Advances in fiber optics and miniaturized actuation technologies allow OCT imaging of the human body and further expand OCT utilization in applications including but not limited to cardiology and gastroenterology. This review article provides an overview of current OCT development and its clinical utility in the gastrointestinal tract, including disease detection/differentiation and endoscopic therapy guidance, as well as a discussion of its future applications.
Collapse
Affiliation(s)
- Tsung-Han Tsai
- NinePoint Medical, Inc., Bedford, Massachusetts, United States
| | - Cadman L Leggett
- Mayo Clinics, Division of Gastroenterology and Hepatology, Rochester, Minnesota, United States
| | - Arvind J Trindade
- North Shore University Hospital and Hofstra Northwell School of Medicine, Division of Gastroenterolo, United States
| | - Amrita Sethi
- Columbia University Medical Center, Department of Gastroenterology, New York City, New York, United States
| | - Anne-Fré Swager
- Spaarne Gasthuis and Free University Medical Center, Amsterdam, The Netherlands
| | - Virendra Joshi
- Ochsner Clinic Foundation, Department of Gastroenterology, New Orleans, Louisiana, United States
| | - Jacques J Bergman
- Academic Medical Center, Department of Gastroenterology and Hepatology, Amsterdam, The Netherlands
| | - Hiroshi Mashimo
- Veterans Affairs Boston Healthcare System and Harvard Medical School, Department of Gastroenterology, United States
| | - Norman S Nishioka
- Massachusetts General Hospital, Gastrointestinal Unit, Boston, Massachusetts, United States
| | - Eman Namati
- NinePoint Medical, Inc., Bedford, Massachusetts, United States
| |
Collapse
|
24
|
Wang T, Pfeiffer T, Wu M, Wieser W, Amenta G, Draxinger W, van der Steen AFW, Huber R, Soest GV. Thermo-elastic optical coherence tomography. OPTICS LETTERS 2017; 42:3466-3469. [PMID: 28957064 DOI: 10.1364/ol.42.003466] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 08/08/2017] [Indexed: 05/23/2023]
Abstract
The absorption of nanosecond laser pulses induces rapid thermo-elastic deformation in tissue. A sub-micrometer scale displacement occurs within a few microseconds after the pulse arrival. In this Letter, we investigate the laser-induced thermo-elastic deformation using a 1.5 MHz phase-sensitive optical coherence tomography (OCT) system. A displacement image can be reconstructed, which enables a new modality of phase-sensitive OCT, called thermo-elastic OCT. An analysis of the results shows that the optical absorption is a dominating factor for the displacement. Thermo-elastic OCT is capable of visualizing inclusions that do not appear on the structural OCT image, providing additional tissue type information.
Collapse
|
25
|
Es’haghian S, Kennedy KM, Gong P, Li Q, Chin L, Wijesinghe P, Sampson DD, McLaughlin RA, Kennedy BF. In vivo volumetric quantitative micro-elastography of human skin. BIOMEDICAL OPTICS EXPRESS 2017; 8:2458-2471. [PMID: 28663884 PMCID: PMC5480491 DOI: 10.1364/boe.8.002458] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 03/23/2017] [Accepted: 03/24/2017] [Indexed: 05/17/2023]
Abstract
In this paper, we demonstrate in vivo volumetric quantitative micro-elastography of human skin. Elasticity is estimated at each point in the captured volume by combining local axial strain measured in the skin with local axial stress estimated at the skin surface. This is achieved by utilizing phase-sensitive detection to measure axial displacements resulting from compressive loading of the skin and an overlying, compliant, transparent layer with known stress/strain behavior. We use an imaging probe head that provides optical coherence tomography imaging and compression from the same direction. We demonstrate our technique on a tissue phantom containing a rigid inclusion, and present in vivo elastograms acquired from locations on the hand, wrist, forearm and leg of human volunteers.
Collapse
Affiliation(s)
- Shaghayegh Es’haghian
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| | - Kelsey M. Kennedy
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, 6 Verdun Street, Nedlands, WA 6009, Australia
| | - Peijun Gong
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| | - Qingyun Li
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| | - Lixin Chin
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, 6 Verdun Street, Nedlands, WA 6009, Australia
- School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| | - Philip Wijesinghe
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, 6 Verdun Street, Nedlands, WA 6009, Australia
| | - David D. Sampson
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
- Centre for Microscopy, Characterisation & Analysis, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| | - Robert A. McLaughlin
- Optical+Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
- Australian Research Council Centre of Excellence for Nanoscale Biophotonics, School of Medicine, Faculty of Health Sciences, University of Adelaide, Adelaide, South Australia, 5005, Australia
| | - Brendan F. Kennedy
- BRITElab, Harry Perkins Institute of Medical Research, QEII Medical Centre, 6 Verdun Street, Nedlands, WA 6009, Australia
- School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
| |
Collapse
|
26
|
Li GY, Cao Y. Mechanics of ultrasound elastography. Proc Math Phys Eng Sci 2017; 473:20160841. [PMID: 28413350 PMCID: PMC5378248 DOI: 10.1098/rspa.2016.0841] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 01/23/2017] [Indexed: 12/19/2022] Open
Abstract
Ultrasound elastography enables in vivo measurement of the mechanical properties of living soft tissues in a non-destructive and non-invasive manner and has attracted considerable interest for clinical use in recent years. Continuum mechanics plays an essential role in understanding and improving ultrasound-based elastography methods and is the main focus of this review. In particular, the mechanics theories involved in both static and dynamic elastography methods are surveyed. They may help understand the challenges in and opportunities for the practical applications of various ultrasound elastography methods to characterize the linear elastic, viscoelastic, anisotropic elastic and hyperelastic properties of both bulk and thin-walled soft materials, especially the in vivo characterization of biological soft tissues.
Collapse
Affiliation(s)
- Guo-Yang Li
- Department of Engineering Mechanics, Institute of Biomechanics and Medical Engineering, AML, Tsinghua University, Beijing 100084, People's Republic of China
| | - Yanping Cao
- Department of Engineering Mechanics, Institute of Biomechanics and Medical Engineering, AML, Tsinghua University, Beijing 100084, People's Republic of China
| |
Collapse
|
27
|
Zvietcovich F, Rolland JP, Yao J, Meemon P, Parker KJ. Comparative study of shear wave-based elastography techniques in optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:35010. [PMID: 28358943 DOI: 10.1117/1.jbo.22.3.035010] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 03/15/2017] [Indexed: 05/03/2023]
Abstract
We compare five optical coherence elastography techniques able to estimate the shear speed of waves generated by one and two sources of excitation. The first two techniques make use of one piezoelectric actuator in order to produce a continuous shear wave propagation or a tone-burst propagation (TBP) of 400 Hz over a gelatin tissue-mimicking phantom. The remaining techniques utilize a second actuator located on the opposite side of the region of interest in order to create three types of interference patterns: crawling waves, swept crawling waves, and standing waves, depending on the selection of the frequency difference between the two actuators. We evaluated accuracy, contrast to noise ratio, resolution, and acquisition time for each technique during experiments. Numerical simulations were also performed in order to support the experimental findings. Results suggest that in the presence of strong internal reflections, single source methods are more accurate and less variable when compared to the two-actuator methods. In particular, TBP reports the best performance with an accuracy error < 4.1 % . Finally, the TBP was tested in a fresh chicken tibialis anterior muscle with a localized thermally ablated lesion in order to evaluate its performance in biological tissue.
Collapse
Affiliation(s)
- Fernando Zvietcovich
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
| | - Jannick P Rolland
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Jianing Yao
- University of Rochester, The Institute of Optics, Rochester, New York, United States
| | - Panomsak Meemon
- University of Rochester, The Institute of Optics, Rochester, New York, United StatescSuranaree University of Technology, School of Physics, Institute of Science, Nakhon Ratchasima, Thailand
| | - Kevin J Parker
- University of Rochester, Department of Electrical and Computer Engineering, Rochester, New York, United States
| |
Collapse
|
28
|
Larin KV, Sampson DD. Optical coherence elastography - OCT at work in tissue biomechanics [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:1172-1202. [PMID: 28271011 PMCID: PMC5330567 DOI: 10.1364/boe.8.001172] [Citation(s) in RCA: 221] [Impact Index Per Article: 31.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Revised: 01/18/2017] [Accepted: 01/19/2017] [Indexed: 05/18/2023]
Abstract
Optical coherence elastography (OCE), as the use of OCT to perform elastography has come to be known, began in 1998, around ten years after the rest of the field of elastography - the use of imaging to deduce mechanical properties of tissues. After a slow start, the maturation of OCT technology in the early to mid 2000s has underpinned a recent acceleration in the field. With more than 20 papers published in 2015, and more than 25 in 2016, OCE is growing fast, but still small compared to the companion fields of cell mechanics research methods, and medical elastography. In this review, we describe the early developments in OCE, and the factors that led to the current acceleration. Much of our attention is on the key recent advances, with a strong emphasis on future prospects, which are exceptionally bright.
Collapse
Affiliation(s)
- Kirill V Larin
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Blvd., Houston, Texas 77204-5060, USA; Department of Molecular Physiology and Biophysics, Baylor College of Medicine, 1 Baylor Plaza, Houston, Texas 77030, USA;
| | - David D Sampson
- Optical + Biomedical Engineering Laboratory, School of Electrical, Electronic & Computer Engineering, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia; Centre for Microscopy, Characterisation & Analysis, The University of Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia;
| |
Collapse
|
29
|
Wang R, Raykin J, Brewster LP, Gleason RL. A Novel Approach to Assess the In Situ Versus Ex Vivo Mechanical Behaviors of the Coronary Artery. J Biomech Eng 2017; 139:2588204. [PMID: 27893049 DOI: 10.1115/1.4035262] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2016] [Indexed: 11/08/2022]
Abstract
Ex vivo mechanical testing has provided tremendous insight toward prediction of the in vivo mechanical behavior and local mechanical environment of the arterial wall; however, the role of perivascular support on the local mechanical behavior of arteries is not well understood. Here, we present a novel approach for quantifying the impact of the perivascular support on arterial mechanics using intravascular ultrasound (IVUS) on cadaveric porcine hearts. We performed pressure-diameter tests (n = 5) on the left anterior descending coronary arteries (LADCAs) in situ while embedded in their native perivascular environment using IVUS imaging and after removal of the perivascular support of the artery. We then performed standard cylindrical biaxial testing on these vessels ex vivo and compared the results. Removal of the perivascular support resulted in an upward shift of the pressure-diameter curve. Ex vivo testing, however, showed significantly lower circumferential compliance compared to the in situ configuration. On a second set of arteries, local axial stretch ratios were quantified (n = 5) along the length of the arteries. The average in situ axial stretch ratio was 1.28 ± 0.16; however, local axial stretch ratios showed significant variability, ranging from 1.01 to 1.70. Taken together, the data suggest that both the perivascular loading and the axial tethering have an important role in arterial mechanics. Combining nondestructive testing using IVUS with traditional ex vivo cylindrical biaxial testing yields a more comprehensive assessment of the mechanical behavior of arteries.
Collapse
Affiliation(s)
- Ruoya Wang
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Julia Raykin
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Luke P Brewster
- Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, Woodruff Memorial Research Building, 101 Woodruff Circle, Suite 5105, Atlanta, GA 30332;Department of Surgery, Emory University School of Medicine, Atlanta, GA 30307; Surgical and Research Services, Atlanta VA Medical Center, Atlanta, GA 30033 e-mail:
| | - Rudolph L Gleason
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332;Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332;Parker H. Petit Institute of Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Drive, IBB 2305, Atlanta, GA 30332 e-mail:
| |
Collapse
|
30
|
Zaitsev VY, Matveyev AL, Matveev LA, Gelikonov GV, Sovetsky AA, Vitkin A. Optimized phase gradient measurements and phase-amplitude interplay in optical coherence elastography. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:116005. [PMID: 27824215 DOI: 10.1117/1.jbo.21.11.116005] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Accepted: 10/18/2016] [Indexed: 05/23/2023]
Abstract
In compressional optical coherence elastography, phase-variation gradients are used for estimating quasistatic strains created in tissue. Using reference and deformed optical coherence tomography (OCT) scans, one typically compares phases from pixels with the same coordinates in both scans. Usually, this limits the allowable strains to fairly small values <10?4 to 10?3, with the caveat that such weak phase gradients may become corrupted by stronger measurement noises. Here, we extend the OCT phase-resolved elastographic methodology by (1) showing that an order of magnitude greater strains can significantly increase the accuracy of derived phase-gradient differences, while also avoiding error-phone phase-unwrapping procedures and minimizing the influence of decorrelation noise caused by suprapixel displacements, (2) discussing the appearance of artifactual stiff inclusions in resultant OCT elastograms in the vicinity of bright scatterers due to the amplitude-phase interplay in phase-variation measurements, and (3) deriving/evaluating methods of phase-gradient estimation that can outperform conventionally used least-square gradient fitting. We present analytical arguments, numerical simulations, and experimental examples to demonstrate the advantages of the proposed optimized phase-variation methodology.
Collapse
Affiliation(s)
- Vladimir Y Zaitsev
- Institute of Applied Physics, Russian Academy of Sciences, 46 Uljanova Street, Nizhny Novgorod 603950, RussiabMedical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod 603005, Russia
| | - Alexander L Matveyev
- Institute of Applied Physics, Russian Academy of Sciences, 46 Uljanova Street, Nizhny Novgorod 603950, RussiabMedical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod 603005, Russia
| | - Lev A Matveev
- Institute of Applied Physics, Russian Academy of Sciences, 46 Uljanova Street, Nizhny Novgorod 603950, RussiabMedical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod 603005, Russia
| | - Grigory V Gelikonov
- Institute of Applied Physics, Russian Academy of Sciences, 46 Uljanova Street, Nizhny Novgorod 603950, RussiabMedical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod 603005, Russia
| | - Aleksandr A Sovetsky
- Institute of Applied Physics, Russian Academy of Sciences, 46 Uljanova Street, Nizhny Novgorod 603950, Russia
| | - Alex Vitkin
- Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod 603005, RussiacUniversity Health Network and University of Toronto, 101 College Street, Toronto, Ontario M5G 1L7, Canada
| |
Collapse
|
31
|
Zhao Y, Chen C, Yang S, Xing D. Mechanical evaluation of lipid accumulation in atherosclerotic tissues by photoacoustic viscoelasticity imaging. OPTICS LETTERS 2016; 41:4522-4525. [PMID: 27749871 DOI: 10.1364/ol.41.004522] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Photoacoustic viscoelasticity imaging (PAVEI) is a technique that directly provides the morphology of biological tissues with correlative mechanical information. In this Letter, we demonstrate the use of PAVEI to successfully characterize early-stage atherosclerotic plaques. Lipid, as the main material in early plaque lesions, embedded in gelatin was imaged to test the feasibility of PAVEI. Atherosclerosis of rabbits was studied ex vivo, and the rabbit arteries were imaged to show the intrinsic contrast of PAVEI. Our results demonstrate that PAVEI can provide valuable viscoelasticity information for early detection of atherosclerotic plaques, which yields new insights into biomechanical diagnosis of cardiovascular diseases.
Collapse
|
32
|
Liu CH, Du Y, Singh M, Wu C, Han Z, Li J, Chang A, Mohan C, Larin KV. Classifying murine glomerulonephritis using optical coherence tomography and optical coherence elastography. JOURNAL OF BIOPHOTONICS 2016; 9:781-91. [PMID: 26791097 PMCID: PMC4956579 DOI: 10.1002/jbio.201500269] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Revised: 12/06/2015] [Accepted: 12/19/2015] [Indexed: 05/18/2023]
Abstract
Acute glomerulonephritis caused by antiglomerular basement membrane marked by high mortality. The primary reason for this is delayed diagnosis via blood examination, urine analysis, tissue biopsy, or ultrasound and X-ray computed tomography imaging. Blood, urine, and tissue-based diagnoses can be time consuming, while ultrasound and CT imaging have relatively low spatial resolution, with reduced sensitivity. Optical coherence tomography is a noninvasive and high-resolution imaging technique that provides superior spatial resolution (micrometer scale) as compared to ultrasound and CT. Changes in tissue properties can be detected based on the optical metrics analyzed from the OCT signals, such as optical attenuation and speckle variance. Furthermore, OCT does not rely on ionizing radiation as with CT imaging. In addition to structural changes, the elasticity of the kidney can significantly change due to nephritis. In this work, OCT has been utilized to quantify the difference in tissue properties between healthy and nephritic murine kidneys. Although OCT imaging could identify the diseased tissue, its classification accuracy is clinically inadequate. By combining optical metrics with elasticity, the classification accuracy improves from 76% to 95%. These results show that OCT combined with OCE can be a powerful tool for identifying and classifying nephritis. Therefore, the OCT/OCE method could potentially be used as a minimally invasive tool for longitudinal studies during the progression and therapy of glomerulonephritis as well as complement and, perhaps, substitute highly invasive tissue biopsies. Elastic-wave propagation in mouse healthy and nephritic kidneys.
Collapse
Affiliation(s)
- Chih-Hao Liu
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Yong Du
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Chen Wu
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Zhaolong Han
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Jiasong Li
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA
| | - Anthony Chang
- Department of Pathology, the University of Chicago, 5841 S. Maryland Avenue, Chicago, IL 60637, USA
| | - Chandra Mohan
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA.
| | - Kirill V Larin
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas, 77204, USA.
- Molecular Physiology and Biophysics, Baylor College of Medicine, One Baylor Plaza, Houston, Texas, 77584, USA.
- Interdisciplinary Laboratory of Biophotonics, Tomsk State University, Tomsk, 634050, Russia.
| |
Collapse
|
33
|
Huang PC, Pande P, Ahmad A, Marjanovic M, Spillman DR, Odintsov B, Boppart SA. Magnetomotive Optical Coherence Elastography for Magnetic Hyperthermia Dosimetry Based on Dynamic Tissue Biomechanics. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2016; 22:6802816. [PMID: 28163565 PMCID: PMC5289667 DOI: 10.1109/jstqe.2015.2505147] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Magnetic nanoparticles (MNPs) have been used in many diagnostic and therapeutic biomedical applications over the past few decades to enhance imaging contrast, steer drugs to targets, and treat tumors via hyperthermia. Optical coherence tomography (OCT) is an optical biomedical imaging modality that relies on the detection of backscattered light to generate high-resolution cross-sectional images of biological tissue. MNPs have been utilized as imaging contrast and perturbative mechanical agents in OCT in techniques called magnetomotive OCT (MM-OCT) and magnetomotive elastography (MM-OCE), respectively. MNPs have also been independently used for magnetic hyperthermia treatments, enabling therapeutic functions such as killing tumor cells. It is well known that the localized tissue heating during hyperthermia treatments result in a change in the biomechanical properties of the tissue. Therefore, we propose a novel dosimetric technique for hyperthermia treatment based on the viscoelasticity change detected by MM-OCE, further enabling the theranostic function of MNPs. In this paper, we first review the basic principles and applications of MM-OCT, MM-OCE, and magnetic hyperthermia, and present new preliminary results supporting the concept of MM-OCE-based hyperthermia dosimetry.
Collapse
Affiliation(s)
- Pin-Chieh Huang
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Paritosh Pande
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Adeel Ahmad
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Marina Marjanovic
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Darold R Spillman
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Boris Odintsov
- Biophotonics Imaging Laboratory and the Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA ( )
| | - Stephen A Boppart
- Biophotonics Imaging Laboratory, Beckman Institute for Advanced Science and Technology, and the Departments of Electrical and Computer Engineering, Bioengineering, and Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA (phone: 217-333-8598; fax: 217-333-5833; )
| |
Collapse
|
34
|
Zaitsev VY, Matveyev AL, Matveev LA, Gelikonov GV, Gubarkova EV, Gladkova ND, Vitkin A. Hybrid method of strain estimation in optical coherence elastography using combined sub-wavelength phase measurements and supra-pixel displacement tracking. JOURNAL OF BIOPHOTONICS 2016; 9:499-509. [PMID: 27159850 DOI: 10.1002/jbio.201500203] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Revised: 10/10/2015] [Accepted: 10/12/2015] [Indexed: 05/25/2023]
Abstract
A novel hybrid method which combines sub-wavelength-scale phase measurements and pixel-scale displacement tracking for robust strain mapping in compressional optical coherence elastography is proposed. Unlike majority of OCE methods it does not rely on initial reconstruction of displacements and does not suffer from the phase-wrapping problem for super-wavelength displacements. Its robustness is enabled by direct fitting of local phase gradients obviating the necessity of phase unwrapping and error-prone numerical differentiation. Furthermore, axial displacements significantly exceeding not only the optical wavelength, but pixel scales (i.e., multiple wavelengths) can be efficiently tracked and compensated. This feature strongly reduces errors in phase-gradient estimation and ensures high robustness with respect to both additive and decorrelation noises. Illustration of exceptionally high tolerance of the proposed method to noises: contrast of only 25% in the stiffness of the layers is clearly seen in the strain map even for equal intensities of the OCT signal and additive noise (SNR = 0 dB).
Collapse
Affiliation(s)
- Vladimir Y Zaitsev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova St., 603950, Nizhny Novgorod, Russia
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
- State University of Nizhny Novgorod, 23 Gagarina avenue, 603950, Nizhny Novgorod, Russia
| | - Alexander L Matveyev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova St., 603950, Nizhny Novgorod, Russia.
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia.
| | - Lev A Matveev
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova St., 603950, Nizhny Novgorod, Russia
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
| | - Grigory V Gelikonov
- Institute of Applied Physics of the Russian Academy of Sciences, 46 Uljanova St., 603950, Nizhny Novgorod, Russia
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
| | - Ekaterina V Gubarkova
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
| | - Natalia D Gladkova
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
| | - Alex Vitkin
- State Medical Academy of Nizhny Novgorod, 1 Minina Square, 10/1 Minina Square, Nizhny Novgorod, 603005, Russia
- University of Toronto, Toronto, Canada
| |
Collapse
|
35
|
Liu XY, Yan F, Niu LL, Chen QN, Zheng HR, Li JY. Strong correlation between early stage atherosclerosis and electromechanical coupling of aorta. NANOSCALE 2016; 8:6975-6980. [PMID: 26972797 DOI: 10.1039/c5nr07398g] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Atherosclerosis is the underlying cause of cardiovascular diseases that are responsible for many deaths in the world, and the early diagnosis of atherosclerosis is highly desirable. The existing imaging methods, however, are not capable of detecting the early stage of atherosclerosis development due to their limited spatial resolution. Using piezoresponse force microscopy (PFM), we show that the piezoelectric response of an aortic wall increases as atherosclerosis advances, while the stiffness of the aorta shows a less evident correlation with atherosclerosis. Furthermore, we show that there is strong correlation between the coercive electric field necessary to switch the polarity of the artery and the development of atherosclerosis. Thus by measuring the electromechanical coupling of the aortic wall, it is possible to probe atherosclerosis at the early stage of its development, not only improving the spatial resolution by orders of magnitude, but also providing comprehensive quantitative information on the biomechanical properties of the artery.
Collapse
Affiliation(s)
- X Y Liu
- College of Metallurgy and Materials Engineering, Chongqing Key Laboratory of Nano/Micro Composites and Devices, Chongqing University of Science & Technology, Chongqing, China
| | - F Yan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China and Shenzhen Key Laboratory of Nanobiomechanics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
| | - L L Niu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China and Shenzhen Key Laboratory of Nanobiomechanics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
| | - Q N Chen
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - H R Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China and Shenzhen Key Laboratory of Nanobiomechanics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
| | - J Y Li
- Department of Mechanical Engineering, University of Washington, Seattle, WA, USA and Shenzhen Key Laboratory of Nanobiomechanics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
| |
Collapse
|
36
|
Kim S, Raphael PD, Oghalai JS, Applegate BE. High-speed spectral calibration by complex FIR filter in phase-sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2016; 7:1430-44. [PMID: 27446666 PMCID: PMC4929652 DOI: 10.1364/boe.7.001430] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2016] [Revised: 03/14/2016] [Accepted: 03/15/2016] [Indexed: 05/03/2023]
Abstract
Swept-laser sources offer a number of advantages for Phase-sensitive Optical Coherence Tomography (PhOCT). However, inter- and intra-sweep variability leads to calibration errors that adversely affect phase sensitivity. While there are several approaches to overcoming this problem, our preferred method is to simply calibrate every sweep of the laser. This approach offers high accuracy and phase stability at the expense of a substantial processing burden. In this approach, the Hilbert phase of the interferogram from a reference interferometer provides the instantaneous wavenumber of the laser, but is computationally expensive. Fortunately, the Hilbert transform may be approximated by a Finite Impulse-Response (FIR) filter. Here we explore the use of several FIR filter based Hilbert transforms for calibration, explicitly considering the impact of filter choice on phase sensitivity and OCT image quality. Our results indicate that the complex FIR filter approach is the most robust and accurate among those considered. It provides similar image quality and slightly better phase sensitivity than the traditional FFT-IFFT based Hilbert transform while consuming fewer resources in an FPGA implementation. We also explored utilizing the Hilbert magnitude of the reference interferogram to calculate an ideal window function for spectral amplitude calibration. The ideal window function is designed to carefully control sidelobes on the axial point spread function. We found that after a simple chromatic correction, calculating the window function using the complex FIR filter and the reference interferometer gave similar results to window functions calculated using a mirror sample and the FFT-IFFT Hilbert transform. Hence, the complex FIR filter can enable accurate and high-speed calibration of the magnitude and phase of spectral interferograms.
Collapse
Affiliation(s)
- Sangmin Kim
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Patrick D. Raphael
- Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, CA, USA
| | - John S. Oghalai
- Department of Otolaryngology, Head and Neck Surgery, Stanford University, Stanford, CA, USA
| | - Brian E. Applegate
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| |
Collapse
|
37
|
Nebelung S, Brill N, Müller F, Tingart M, Pufe T, Merhof D, Schmitt R, Jahr H, Truhn D. Towards Optical Coherence Tomography-based elastographic evaluation of human cartilage. J Mech Behav Biomed Mater 2016; 56:106-119. [DOI: 10.1016/j.jmbbm.2015.11.025] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2015] [Revised: 11/21/2015] [Accepted: 11/25/2015] [Indexed: 10/22/2022]
|
38
|
Ling Y, Li C, Feng K, Duncan R, Eisma R, Huang Z, Nabi G. Effects of fixation and preservation on tissue elastic properties measured by quantitative optical coherence elastography (OCE). J Biomech 2016; 49:1009-1015. [PMID: 26903410 DOI: 10.1016/j.jbiomech.2016.02.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 01/21/2016] [Accepted: 02/05/2016] [Indexed: 11/25/2022]
Abstract
Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design and performance of such instruments. Understanding the effects of storage and preservation conditions on the mechanical properties of soft tissue has both clinical and experimental significance. To this end, we aimed to study the effects of tissue preservation (by 10% formalin and Thiel fluids) on the elastic properties of five different kinds of fresh tissues from pig and chicken; specifically fat, liver, muscle, tendon and cartilage. The tissue elasticity was measured intensively and strictly within a controlled timeline of 6 months by quantitative optical coherence elastography (OCE) system. Our findings suggest that the elasticity change of tissues in the formalin solution has an ascending trend, but that of Thiel remains almost constant, providing a more real texture and properties.
Collapse
Affiliation(s)
- Yuting Ling
- Academic Section of Urology, Division of Imaging Technology, School of Medicine, University of Dundee, Dundee DD1 9SY, Scotland, UK; School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN, Scotland, UK
| | - Chunhui Li
- Academic Section of Urology, Division of Imaging Technology, School of Medicine, University of Dundee, Dundee DD1 9SY, Scotland, UK; School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN, Scotland, UK.
| | - Kairui Feng
- School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN, Scotland, UK
| | - Robyn Duncan
- Centers for Anatomy and Human Identification, College of Life Sciences, University of Dundee, Dundee DD1 4HN, UK
| | - Roos Eisma
- Centers for Anatomy and Human Identification, College of Life Sciences, University of Dundee, Dundee DD1 4HN, UK
| | - Zhihong Huang
- School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN, Scotland, UK
| | - Ghulam Nabi
- Academic Section of Urology, Division of Imaging Technology, School of Medicine, University of Dundee, Dundee DD1 9SY, Scotland, UK
| |
Collapse
|
39
|
Application of Elastography for the Noninvasive Assessment of Biomechanics in Engineered Biomaterials and Tissues. Ann Biomed Eng 2016; 44:705-24. [PMID: 26790865 DOI: 10.1007/s10439-015-1542-x] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 12/18/2015] [Indexed: 12/11/2022]
Abstract
The elastic properties of engineered biomaterials and tissues impact their post-implantation repair potential and structural integrity, and are critical to help regulate cell fate and gene expression. The measurement of properties (e.g., stiffness or shear modulus) can be attained using elastography, which exploits noninvasive imaging modalities to provide functional information of a material indicative of the regeneration state. In this review, we outline the current leading elastography methodologies available to characterize the properties of biomaterials and tissues suitable for repair and mechanobiology research. We describe methods utilizing magnetic resonance, ultrasound, and optical coherent elastography, highlighting their potential for longitudinal monitoring of implanted materials in vivo, in addition to spatiotemporal limits of each method for probing changes in cell-laden constructs. Micro-elastography methods now allow acquisitions at length scales approaching 5-100 μm in two and three dimensions. Many of the methods introduced in this review are therefore capable of longitudinal monitoring in biomaterials and tissues approaching the cellular scale. However, critical factors such as anisotropy, heterogeneity and viscoelasity-inherent in many soft tissues-are often not fully described and therefore require further advancements and future developments.
Collapse
|
40
|
Bu R, Price H, Mitran S, Zdanski C, Oldenburg AL. Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2016; 9689:968923. [PMID: 27746580 PMCID: PMC5061295 DOI: 10.1117/12.2213186] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Quantitative endoscopic imaging is at the vanguard of novel techniques in the assessment upper airway obstruction. Anatomic optical coherence tomography (aOCT) has the potential to provide the geometry of the airway lumen with high-resolution and in 4 dimensions. By coupling aOCT with measurements of pressure, optical coherence elastography (OCE) can be performed to characterize airway wall stiffness. This can aid in identifying regions of dynamic collapse as well as informing computational fluid dynamics modeling to aid in surgical decision-making. Toward this end, here we report on an anatomic optical coherence tomography (aOCT) system powered by a wavelength-swept laser source. The system employs a fiber-optic catheter with outer diameter of 0.82 mm deployed via the bore of a commercial, flexible bronchoscope. Helical scans are performed to measure the airway geometry and to quantify the cross-sectional-area (CSA) of the airway. We report on a preliminary validation of aOCT for elastography, in which aOCT-derived CSA was obtained as a function of pressure to estimate airway wall compliance. Experiments performed on a Latex rubber tube resulted in a compliance measurement of 0.68±0.02 mm2/cmH2O, with R2=0.98 over the pressure range from 10 to 40 cmH2O. Next, ex vivo porcine trachea was studied, resulting in a measured compliance from 1.06±0.12 to 3.34±0.44 mm2/cmH2O, (R2>0.81). The linearity of the data confirms the elastic nature of the airway. The compliance values are within the same order-of-magnitude as previous measurements of human upper airways, suggesting that this system is capable of assessing airway wall compliance in future human studies.
Collapse
Affiliation(s)
- Ruofei Bu
- Department of Biomedical Engineering, University of North Carolina at Chapel Hill, North Carolina, USA, 27599
| | - Hillel Price
- Department of Physics and Astronomy, University of North Carolina at Chapel Hill, North Carolina, USA, 27599
| | - Sorin Mitran
- Department of Mathematics, University of North Carolina at Chapel Hill, North Carolina, USA, 27599
| | - Carlton Zdanski
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, North Carolina, USA, 27599
| | - Amy L Oldenburg
- Department of Biomedical Engineering, University of North Carolina at Chapel Hill, North Carolina, USA, 27599; Department of Physics and Astronomy, University of North Carolina at Chapel Hill, North Carolina, USA, 27599; Biomedical Research Imaging Center; University of North Carolina at Chapel Hill, North Carolina, USA, 27599
| |
Collapse
|
41
|
Witzenburg CM, Dhume RY, Lake SP, Barocas VH. Automatic Segmentation of Mechanically Inhomogeneous Tissues Based on Deformation Gradient Jump. IEEE TRANSACTIONS ON MEDICAL IMAGING 2016; 35:29-41. [PMID: 26168433 PMCID: PMC4739827 DOI: 10.1109/tmi.2015.2453316] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Variations in properties, active behavior, injury, scarring, and/or disease can all cause a tissue's mechanical behavior to be heterogeneous. Advances in imaging technology allow for accurate full-field displacement tracking of both in vitro and in vivo deformation from an applied load. While detailed strain fields provide some insight into tissue behavior, material properties are usually determined by fitting stress-strain behavior with a constitutive equation. However, the determination of the mechanical behavior of heterogeneous soft tissue requires a spatially varying constitutive equation (i.e., one in which the material parameters vary with position). We present an approach that computationally dissects the sample domain into many homogeneous subdomains, wherein subdomain boundaries are formed by applying a betweenness based graphical analysis to the deformation gradient field to identify locations with large discontinuities. This novel partitioning technique successfully determined the shape, size and location of regions with locally similar material properties for: (1) a series of simulated soft tissue samples prescribed with both abrupt and gradual changes in anisotropy strength, prescribed fiber alignment, stiffness, and nonlinearity, (2) tissue analogs (PDMS and collagen gels) which were tested biaxially and speckle tracked (3) and soft tissues which exhibited a natural variation in properties (cadaveric supraspinatus tendon), a pathologic variation in properties (thoracic aorta containing transmural plaque), and active behavior (contracting cardiac sheet). The routine enables the dissection of samples computationally rather than physically, allowing for the study of small tissues specimens with unknown and irregular inhomogeneity.
Collapse
Affiliation(s)
- Colleen M. Witzenburg
- University of Minnesota, Minneapolis, MN 55455 USA and is now with the University of Virginia, Charlottesville, VA 22908 USA
| | | | - Spencer P. Lake
- University of Minnesota, Minneapolis, MN 55455 USA as is now with Washington University, St. Louis, MO 63130 USA
| | | |
Collapse
|
42
|
Han Z, Li J, Singh M, Wu C, Liu CH, Wang S, Idugboe R, Raghunathan R, Sudheendran N, Aglyamov SR, Twa MD, Larin KV. Quantitative methods for reconstructing tissue biomechanical properties in optical coherence elastography: a comparison study. Phys Med Biol 2015; 60:3531-47. [PMID: 25860076 PMCID: PMC4409577 DOI: 10.1088/0031-9155/60/9/3531] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
We present a systematic analysis of the accuracy of five different methods for extracting the biomechanical properties of soft samples using optical coherence elastography (OCE). OCE is an emerging noninvasive technique, which allows assessment of biomechanical properties of tissues with micrometer spatial resolution. However, in order to accurately extract biomechanical properties from OCE measurements, application of a proper mechanical model is required. In this study, we utilize tissue-mimicking phantoms with controlled elastic properties and investigate the feasibilities of four available methods for reconstructing elasticity (Young's modulus) based on OCE measurements of an air-pulse induced elastic wave. The approaches are based on the shear wave equation (SWE), the surface wave equation (SuWE), Rayleigh-Lamb frequency equation (RLFE), and finite element method (FEM), Elasticity values were compared with uniaxial mechanical testing. The results show that the RLFE and the FEM are more robust in quantitatively assessing elasticity than the other simplified models. This study provides a foundation and reference for reconstructing the biomechanical properties of tissues from OCE data, which is important for the further development of noninvasive elastography methods.
Collapse
Affiliation(s)
- Zhaolong Han
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Jiasong Li
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Manmohan Singh
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Chen Wu
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Chih-hao Liu
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Shang Wang
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| | - Rita Idugboe
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Raksha Raghunathan
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Narendran Sudheendran
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
| | - Salavat R. Aglyamov
- Department of Biomedical Engineering, University of Texas at Austin, 107 W Dean Keeton Street, Austin, TX 78712, USA
| | - Michael D. Twa
- School of Optometry, University of Alabama, Birmingham, AL 35294 USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, Cullen College of Engineering, University of Houston, Houston, TX 77204, USA
- Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, TX 77030, USA
| |
Collapse
|
43
|
Lu M, Tang Y, Sun R, Wang T, Chen S, Mao R. A real time displacement estimation algorithm for ultrasound elastography. COMPUT IND 2015. [DOI: 10.1016/j.compind.2014.09.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
44
|
Wang S, Larin KV. Optical coherence elastography for tissue characterization: a review. JOURNAL OF BIOPHOTONICS 2015; 8:279-302. [PMID: 25412100 PMCID: PMC4410708 DOI: 10.1002/jbio.201400108] [Citation(s) in RCA: 135] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2014] [Revised: 10/24/2014] [Accepted: 10/24/2014] [Indexed: 05/05/2023]
Abstract
Optical coherence elastography (OCE) represents the frontier of optical elasticity imaging techniques and focuses on the micro-scale assessment of tissue biomechanics in 3D that is hard to achieve with traditional elastographic methods. Benefit from the advancement of optical coherence tomography, and driven by the increasing requirements in nondestructive biomechanical characterization, this emerging technique recently has experienced a rapid development. In this paper, we start with the description of the mechanical contrast that has been employed by OCE and review the state-of-the-art techniques based on the reported applications and discuss the current technical challenges, emphasizing the unique role of OCE in tissue mechanical characterization. The position of OCE among other elastography techniques.
Collapse
Affiliation(s)
- Shang Wang
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Blvd., Houston, Texas, 77204-5060, USA; Department of Molecular Physiology and Biophysics, Baylor College of medicine, one Baylor Plaza, Houston, Texas, 77030, USA
| | | |
Collapse
|
45
|
Wang S, Larin KV. Optical coherence elastography for tissue characterization: a review. JOURNAL OF BIOPHOTONICS 2015. [PMID: 25412100 DOI: 10.1002/jbio.v8.4] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Optical coherence elastography (OCE) represents the frontier of optical elasticity imaging techniques and focuses on the micro-scale assessment of tissue biomechanics in 3D that is hard to achieve with traditional elastographic methods. Benefit from the advancement of optical coherence tomography, and driven by the increasing requirements in nondestructive biomechanical characterization, this emerging technique recently has experienced a rapid development. In this paper, we start with the description of the mechanical contrast that has been employed by OCE and review the state-of-the-art techniques based on the reported applications and discuss the current technical challenges, emphasizing the unique role of OCE in tissue mechanical characterization. The position of OCE among other elastography techniques.
Collapse
Affiliation(s)
- Shang Wang
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Blvd., Houston, Texas, 77204-5060, USA; Department of Molecular Physiology and Biophysics, Baylor College of medicine, one Baylor Plaza, Houston, Texas, 77030, USA
| | | |
Collapse
|
46
|
Lee JH, Kim YN, Park HJ. Bio-optics based sensation imaging for breast tumor detection using tissue characterization. SENSORS 2015; 15:6306-23. [PMID: 25785306 PMCID: PMC4435184 DOI: 10.3390/s150306306] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2015] [Revised: 03/02/2015] [Accepted: 03/04/2015] [Indexed: 12/21/2022]
Abstract
The tissue inclusion parameter estimation method is proposed to measure the stiffness as well as geometric parameters. The estimation is performed based on the tactile data obtained at the surface of the tissue using an optical tactile sensation imaging system (TSIS). A forward algorithm is designed to comprehensively predict the tactile data based on the mechanical properties of tissue inclusion using finite element modeling (FEM). This forward information is used to develop an inversion algorithm that will be used to extract the size, depth, and Young's modulus of a tissue inclusion from the tactile data. We utilize the artificial neural network (ANN) for the inversion algorithm. The proposed estimation method was validated by a realistic tissue phantom with stiff inclusions. The experimental results showed that the proposed estimation method can measure the size, depth, and Young's modulus of a tissue inclusion with 0.58%, 3.82%, and 2.51% relative errors, respectively. The obtained results prove that the proposed method has potential to become a useful screening and diagnostic method for breast cancer.
Collapse
Affiliation(s)
- Jong-Ha Lee
- Department of Biomedical Engineering, School of Medicine, Keimyung University, 1095, Dalgubeol-daero, Daegu 704-701, Korea.
| | - Yoon Nyun Kim
- Department of Internal Medicine, Dongsan Medical Center, Keimyung University, 1095, Dalgubeol-daero, Daegu 704-701, Korea.
| | - Hee-Jun Park
- Department of Biomedical Engineering, School of Medicine, Keimyung University, 1095, Dalgubeol-daero, Daegu 704-701, Korea.
| |
Collapse
|
47
|
Gurjarpadhye AA, DeWitt MR, Xu Y, Wang G, Rylander MN, Rylander CG. Dynamic Assessment of the Endothelialization of Tissue-Engineered Blood Vessels Using an Optical Coherence Tomography Catheter-Based Fluorescence Imaging System. Tissue Eng Part C Methods 2015; 21:758-66. [PMID: 25539889 DOI: 10.1089/ten.tec.2014.0345] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Lumen endothelialization of bioengineered vascular scaffolds is essential to maintain small-diameter graft patency and prevent thrombosis postimplantation. Unfortunately, nondestructive imaging methods to visualize this dynamic process are lacking, thus slowing development and clinical translation of these potential tissue-engineering approaches. To meet this need, a fluorescence imaging system utilizing a commercial optical coherence tomography (OCT) catheter was designed to visualize graft endothelialization. METHODS C7 DragonFly™ intravascular OCT catheter was used as a channel for delivery and collection of excitation and emission spectra. Poly-dl-lactide (PDLLA) electrospun scaffolds were seeded with endothelial cells (ECs). Seeded cells were exposed to Calcein AM before imaging, causing the living cells to emit green fluorescence in response to blue laser. By positioning the catheter tip precisely over a specimen using high-fidelity electromechanical components, small regions of the specimen were excited selectively. The resulting fluorescence intensities were mapped on a two-dimensional digital grid to generate spatial distribution of fluorophores at single-cell-level resolution. Fluorescence imaging of endothelialization on glass and PDLLA scaffolds was performed using the OCT catheter-based imaging system as well as with a commercial fluorescence microscope. Cell coverage area was calculated for both image sets for quantitative comparison of imaging techniques. Tubular PDLLA scaffolds were maintained in a bioreactor on seeding with ECs, and endothelialization was monitored over 5 days using the OCT catheter-based imaging system. RESULTS No significant difference was observed in images obtained using our imaging system to those acquired with the fluorescence microscope. Cell area coverage calculated using the images yielded similar values. Nondestructive imaging of endothelialization on tubular scaffolds showed cell proliferation with cell coverage area increasing from 15 ± 4% to 89 ± 6% over 5 days. CONCLUSION In this study, we showed the capability of an OCT catheter-based imaging system to obtain single-cell resolution and to quantify endothelialization in tubular electrospun scaffolds. We also compared the resulting images with traditional microscopy, showing high fidelity in image capability. This imaging system, used in conjunction with OCT, could potentially be a powerful tool for in vitro optimization of scaffold cellularization, ensuring long-term graft patency postimplantation.
Collapse
Affiliation(s)
- Abhijit Achyut Gurjarpadhye
- 1 School of Biomedical Engineering and Sciences, Virginia Polytechnic Institute and State University , Blacksburg, Virginia
| | - Matthew R DeWitt
- 1 School of Biomedical Engineering and Sciences, Virginia Polytechnic Institute and State University , Blacksburg, Virginia
| | - Yong Xu
- 2 Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University , Blacksburg, Virginia
| | - Ge Wang
- 3 Biomedical Imaging Cluster, Rensselaer Polytechnic Institute , Troy, New York
| | | | - Christopher G Rylander
- 4 Department of Mechanical Engineering, The University of Texas at Austin , Austin, Texas
| |
Collapse
|
48
|
Wu C, Han Z, Wang S, Li J, Singh M, Liu CH, Aglyamov S, Emelianov S, Manns F, Larin KV. Assessing age-related changes in the biomechanical properties of rabbit lens using a coaligned ultrasound and optical coherence elastography system. Invest Ophthalmol Vis Sci 2015; 56:1292-300. [PMID: 25613945 DOI: 10.1167/iovs.14-15654] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
PURPOSE To evaluate the capability of a novel, coaligned focused ultrasound and phase-sensitive optical coherence elastography (US-OCE) system to assess age-related changes in biomechanical properties of the crystalline lens in situ. METHODS Low-amplitude elastic deformations in young and mature rabbit lenses were measured by an US-OCE system consisting of a spectral-domain optical coherence tomography (OCT) system coaligned with a focused ultrasound system used to produce a transient force on the lens surface. Uniaxial compressional tests were used to validate the OCE data. RESULTS The OCE measurements showed that the maximum displacements of the young rabbit lenses were significantly larger than those of the mature lenses, indicating a gradual increase of the lens stiffness with age. Temporal analyses of the displacements also demonstrate a similar trend of elastic properties in these lenses. The stress-strain measurements using uniaxial mechanical tests confirmed the results obtained by the US-OCE system. CONCLUSIONS The results demonstrate that the US-OCE system can be used for noninvasive analysis and quantification of lens biomechanical properties in situ and possibly in vivo.
Collapse
Affiliation(s)
- Chen Wu
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
| | - Zhaolong Han
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
| | - Shang Wang
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, United States
| | - Jiasong Li
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
| | - Chih-Hao Liu
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States
| | - Salavat Aglyamov
- Department of Biomedical Engineering, University of Texas at Austin, Austin, Texas, United States
| | - Stanislav Emelianov
- Department of Biomedical Engineering, University of Texas at Austin, Austin, Texas, United States
| | - Fabrice Manns
- Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, United States Biomedical Optics and Laser Laboratory, Department of Biomedical Engineering, University of Miami College of Engineering, Coral Gables, Florida, United States
| | - Kirill V Larin
- Department of Biomedical Engineering, University of Houston, Houston, Texas, United States Molecular Physiology and Biophysics, Baylor College of Medicine, Houston, Texas, United States
| |
Collapse
|
49
|
Abstract
It is now clearly established that Thin-Capped Fibroatheromas (TCFAs) lead to most Acute Coronary Syndromes (ACSs). The ability to selectively intervene on TCFAs predisposed to rupture and ACSs would dramatically alter the practice of cardiology. While the ability of OCT to identify thin walled plaques at micron scale resolutions has represented a major advance, it is a misconception that it can reliably identify TCFAs. One major reason is that the 'diffuse border' criteria currently used to determine 'lipid plaque' is almost undoubtedly from high scattering in the intima and not because of core composition (necrotic core). A second reason is that, rather than looking at lipid collections, studies need to be focused on identifying necrotic cores with OCT. Necrotic cores are characteristic of TCFAs and not lipid collections. Numerous other OCT approaches are available which can potentially accurately assess TCFAs, but these have not been aggressively pursed which we believe likely stems in part from the misconceptions over the efficacy of 'diffuse borders'.
Collapse
Affiliation(s)
- Mark E Brezinski
- Center for Optics and Modern Physics, Brigham and Women's Hospital, Boston, M.A, USA.,Harvard Medical School, Boston, M.A, USA.,Department of Electrical Engineering, Massachusetts Institute of Technology, Cambridge, M.A, USA
| | - Kishore J Harjai
- Richard and Marion Pearsall Heart Hospital, Geisinger Clinic, Wilkes-Barre, PA, USA
| |
Collapse
|
50
|
Brezinski ME. Practical Challenges of Current Video Rate OCT Elastography: Accounting for Dynamic and Static Tissue Properties. JOURNAL OF LASERS, OPTICS & PHOTONICS 2014; 1:112. [PMID: 29286052 PMCID: PMC5743221 DOI: 10.4172/2469-410x.1000112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Optical coherence tomography (OCT) elastography (OCTE) has the potential to be an important diagnostic tool for pathologies including coronary artery disease, osteoarthritis, malignancies, and even dental caries. Many groups have performed OCTE, including our own, using a wide range of approaches. However, we will demonstrate current OCTE approaches are not scalable to real-time, in vivo imaging. As will be discussed, among the most important reasons is current designs focus on the system and not the target. Specifically, tissue dynamic responses are not accounted, with examples being the tissue strain response time, preload variability, and conditioning variability. Tissue dynamic responses, and to a lesser degree static tissue properties, prevent accurate video rate modulus assessments for current embodiments. Accounting for them is the focus of this paper. A top-down approach will be presented to overcome these challenges to real time in vivo tissue characterization. Discussed first is an example clinical scenario where OTCE would be of substantial relevance, the prevention of acute myocardial infarction or heart attacks. Then the principles behind OCTE are examined. Next, constrains on in vivo application of current OCTE are evaluated, focusing on dynamic tissue responses. An example is the tissue strain response, where it takes about 20 msec after a stress is applied to reach plateau. This response delay is not an issue at slow acquisition rates, as most current OCTE approaches are preformed, but it is for video rate OCTE. Since at video rate each frame is only 30 msec, for essentially all current approaches this means the strain for a given stress is changing constantly during the B-scan. Therefore the modulus can't be accurately assessed. This serious issue is an even greater problem for pulsed techniques as it means the strain/modulus for a given stress (at a location) is unpredictably changing over a B-scan. The paper concludes by introducing a novel video rate approach to overcome these challenges.
Collapse
Affiliation(s)
- Mark E Brezinski
- Center for Optics and Modern Physics, Brigham and Women’s Hospital, 75 Francis Street, Boston, M.A. 02115, USA
- Harvard Medical School, 25 Shattuck Street, Boston, M.A. 02115, USA
- Department of Electrical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, M.A. 02139, USA
| |
Collapse
|