1
|
Handy C, Chaudhry MS, Qureshi MRA, Love B, Shillingford J, Plum-Mörschel L, Zijlstra E. Noninvasive Continuous Glucose Monitoring With a Novel Wearable Dial Resonating Sensor: A Clinical Proof-of-Concept Study. J Diabetes Sci Technol 2024; 18:1408-1415. [PMID: 37102600 PMCID: PMC11529082 DOI: 10.1177/19322968231170242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/28/2023]
Abstract
BACKGROUND A noninvasive, wearable continuous glucose monitor would be a major advancement in diabetes therapy. This trial investigated a novel noninvasive glucose monitor which analyzes spectral variations in radio frequency/microwave signals reflected from the wrist. METHODS A single-arm, open-label, experimental study compared glucose values from a prototype investigational device with laboratory glucose measurements from venous blood samples (Super GL Glucose Analyzer, Dr. Müller Gerätebau GmbH) at varying levels of glycemia. The study included 29 male participants with type 1 diabetes (age range = 19-56 years). The study comprised three stages with the following aims: (1) demonstrate initial proof-of-principle, (2) test an improved device design, and (3) test performance on two consecutive days without device recalibration. The co-primary endpoints in all trial stages were median and mean absolute relative difference (ARD) calculated across all data points. RESULTS In stage 1, the median and mean ARDs were 30% and 46%, respectively. Stage 2 produced marked performance improvements with a median and mean ARD of 22% and 28%, respectively. Stage 3 showed that, without recalibration, the device performed as well as the initial prototype (stage 1) with a median and mean ARD of 35% and 44%, respectively. CONCLUSION This proof-of-concept study shows that a novel noninvasive continuous glucose monitor was capable of detecting glucose levels. Furthermore, the ARD results are comparable to first models of commercially available minimally invasive products without the need to insert a needle. The prototype has been further developed and is being tested in subsequent studies. TRIAL REGISTRATION NUMBER NCT05023798.
Collapse
|
2
|
Zhu T, Li K, Herrero P, Georgiou P. GluGAN: Generating Personalized Glucose Time Series Using Generative Adversarial Networks. IEEE J Biomed Health Inform 2023; 27:5122-5133. [PMID: 37134028 DOI: 10.1109/jbhi.2023.3271615] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Time series data generated by continuous glucose monitoring sensors offer unparalleled opportunities for developing data-driven approaches, especially deep learning-based models, in diabetes management. Although these approaches have achieved state-of-the-art performance in various fields such as glucose prediction in type 1 diabetes (T1D), challenges remain in the acquisition of large-scale individual data for personalized modeling due to the elevated cost of clinical trials and data privacy regulations. In this work, we introduce GluGAN, a framework specifically designed for generating personalized glucose time series based on generative adversarial networks (GANs). Employing recurrent neural network (RNN) modules, the proposed framework uses a combination of unsupervised and supervised training to learn temporal dynamics in latent spaces. Aiming to assess the quality of synthetic data, we apply clinical metrics, distance scores, and discriminative and predictive scores computed by post-hoc RNNs in evaluation. Across three clinical datasets with 47 T1D subjects (including one publicly available and two proprietary datasets), GluGAN achieved better performance for all the considered metrics when compared with four baseline GAN models. The performance of data augmentation is evaluated by three machine learning-based glucose predictors. Using the training sets augmented by GluGAN significantly reduced the root mean square error for the predictors over 30 and 60-minute horizons. The results suggest that GluGAN is an effective method in generating high-quality synthetic glucose time series and has the potential to be used for evaluating the effectiveness of automated insulin delivery algorithms and as a digital twin to substitute for pre-clinical trials.
Collapse
|
3
|
Kumar S, Soldatos G, Ranasinha S, Teede H, Pallin M. Continuous glucose monitoring versus self-monitoring of blood glucose in the management of cystic fibrosis related diabetes: A systematic review and meta-analysis. J Cyst Fibros 2023; 22:39-49. [PMID: 35906171 DOI: 10.1016/j.jcf.2022.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 06/20/2022] [Accepted: 07/20/2022] [Indexed: 10/16/2022]
Abstract
BACKGROUND Treatment of cystic fibrosis related diabetes (CFRD) can improve outcomes and use of continuous glucose monitoring (CGM) can positively impact glycemic control. We conducted a systematic review to assess current evidence on CGM compared to self-monitoring of blood glucose (SMBG) in the management of CFRD to determine its effect on glycemic, pulmonary, non-pulmonary and quality of life outcomes. METHODS Using pre-defined selection criteria, we searched MEDLINE, Embase, CENTRAL, Evidence-Based Medicine Reviews, grey literature and six relevant journals for studies using CGM and/or SMBG in CFRD with greater than 6 weeks of follow-up and reported change in HbA1c. The primary outcome was weighted mean difference (WMD) in plasma HbA1c between CGM and SMBG groups. Secondary outcomes included exploring interrelationships between CGM metrics and effects on disease-specific pulmonary, non-pulmonary and quality of life outcomes. RESULTS A total of 1671 references were retrieved, 862 studies screened and 124 full-texts assessed for eligibility. No studies directly compared CGM to SMBG. A meta-analysis of seventeen studies of 416 individuals (CGM = 138, SMBG = 278) found CGM group had 4.1 mmol/mol (95% CI -7.9 to -0.30, p = 0.034) lower HbA1c compared to SMBG group. Most studies demonstrated moderate-to-high risk of bias. Publication bias was also present. Heterogeneity was high and meta-regression identified duration of follow-up in SMBG group as main contributor. CONCLUSION Our findings suggest use of CGM may be associated with improved glycemic control compared to SMBG in CFRD, however evidence of benefit on pulmonary, non-pulmonary and psychosocial outcomes are lacking.
Collapse
Affiliation(s)
- Shanal Kumar
- Monash Centre for Health Research and Implementation, School of Public Health and Preventive Medicine, Monash University, Level 1, 43-51 Kanooka Grove, Clayton, VIC 3168, Australia; Diabetes and Vascular Medicine Unit, Monash Health, 246 Clayton Road, Clayton, VIC 3168, Australia
| | - Georgia Soldatos
- Monash Centre for Health Research and Implementation, School of Public Health and Preventive Medicine, Monash University, Level 1, 43-51 Kanooka Grove, Clayton, VIC 3168, Australia; Diabetes and Vascular Medicine Unit, Monash Health, 246 Clayton Road, Clayton, VIC 3168, Australia
| | - Sanjeeva Ranasinha
- Monash Centre for Health Research and Implementation, School of Public Health and Preventive Medicine, Monash University, Level 1, 43-51 Kanooka Grove, Clayton, VIC 3168, Australia
| | - Helena Teede
- Monash Centre for Health Research and Implementation, School of Public Health and Preventive Medicine, Monash University, Level 1, 43-51 Kanooka Grove, Clayton, VIC 3168, Australia; Diabetes and Vascular Medicine Unit, Monash Health, 246 Clayton Road, Clayton, VIC 3168, Australia
| | - Michael Pallin
- Monash Lung and Sleep, Monash Health, 246 Clayton Road, Clayton, VIC 3168, Australia.
| |
Collapse
|
4
|
Teo E, Hassan N, Tam W, Koh S. Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis. Diabetologia 2022; 65:604-619. [PMID: 35141761 DOI: 10.1007/s00125-021-05648-4] [Citation(s) in RCA: 62] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 11/02/2021] [Indexed: 12/13/2022]
Abstract
AIMS/HYPOTHESIS The aim of this work was to assess the effectiveness of continuous glucose monitoring (CGM) vs self-monitoring of blood glucose (SMBG) in maintaining glycaemic control among people with type 1 diabetes mellitus. METHODS Cochrane Library, PubMed, Embase, CINAHL, Scopus, trial registries and grey literature were searched from 9 June 2011 until 22 December 2020 for RCTs comparing CGM intervention against SMBG control among the non-pregnant individuals with type 1 diabetes mellitus of all ages and both sexes on multiple daily injections or continuous subcutaneous insulin infusion with HbA1c levels, severe hypoglycaemia and diabetic ketoacidosis (DKA) as outcomes. Studies also included any individual or caregiver-led CGM systems. Studies involving GlucoWatch were excluded. Risk of bias was appraised with Cochrane risk of bias tool. Meta-analysis and meta-regression were performed using Review Manager software and R software, respectively. Heterogeneity was evaluated using χ2 and I2 statistics. Overall effects and certainty of evidence were evaluated using Z statistic and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) software. RESULTS Twenty-two studies, involving 2188 individuals with type 1 diabetes, were identified. Most studies had low risk of bias. Meta-analysis of 21 studies involving 2149 individuals revealed that CGM significantly decreased HbA1c levels compared with SMBG (mean difference -2.46 mmol/mol [-0.23%] [95% CI -3.83, -1.08], Z = 3.50, p=0.0005), with larger effects experienced among higher baseline HbA1c >64 mmol/mol (>8%) individuals (mean difference -4.67 mmol/mol [-0.43%] [95% CI -6.04, -3.30], Z = 6.69, p<0.00001). However, CGM had no influence on the number of severe hypoglycaemia (p=0.13) and DKA events (p=0.88). Certainty of evidence was moderate. CONCLUSIONS/INTERPRETATION CGM is superior to SMBG in improving glycaemic control among individuals with type 1 diabetes in the community, especially in those with uncontrolled glycaemia. Individuals with type 1 diabetes with HbA1c >64 mmol/mol (>8%) are most likely to benefit from CGM. Current findings could not confer a concrete conclusion on the effectiveness of CGM on DKA outcome as DKA incidences were rare. Current evidence is also limited to outpatient settings. Future research should evaluate the accuracy of CGM and the effectiveness of CGM across different age groups and insulin regimens as these remain unclear in this paper. PROSPERO REGISTRATION Registration no. CRD42020207042. FUNDING This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.
Collapse
Affiliation(s)
- Evelyn Teo
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Republic of Singapore.
| | | | - Wilson Tam
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Republic of Singapore
| | - Serena Koh
- Alice Lee Centre for Nursing Studies, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Republic of Singapore.
| |
Collapse
|
5
|
Davis J, Fischl AH, Beck J, Browning L, Carter A, Condon JE, Dennison M, Francis T, Hughes PJ, Jaime S, Lau KHK, McArthur T, McAvoy K, Magee M, Newby O, Ponder SW, Quraishi U, Rawlings K, Socke J, Stancil M, Uelmen S, Villalobos S. 2022 National Standards for Diabetes Self-Management Education and Support. Diabetes Spectr 2022; 35:137-149. [PMID: 35668879 PMCID: PMC9160547 DOI: 10.2337/ds22-ps02] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Affiliation(s)
| | | | - Joni Beck
- The University of Oklahoma Health Science Center, Oklahoma City, OK
| | | | | | - Jo Ellen Condon
- Anne Arundel Medical Center, Annapolis, MD
- Diabetes Alliance Network, Naples, FL
| | | | | | | | | | | | | | | | - Michelle Magee
- MedStar Diabetes and Research Institutes, Georgetown University School of Medicine, Washington, DC
| | - Olivia Newby
- The Healthy Living Center Diabetes Education Program, Norfolk, VA
| | | | | | | | | | | | - Sacha Uelmen
- Association of Diabetes Care & Education Specialists, Chicago, IL
| | | |
Collapse
|
6
|
Davis J, Fischl AH, Beck J, Browning L, Carter A, Condon JE, Dennison M, Francis T, Hughes PJ, Jaime S, Lau KHK, McArthur T, McAvoy K, Magee M, Newby O, Ponder SW, Quraishi U, Rawlings K, Socke J, Stancil M, Uelmen S, Villalobos S. 2022 National Standards for Diabetes Self-Management Education and Support. Diabetes Care 2022; 45:484-494. [PMID: 35050365 DOI: 10.2337/dc21-2396] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 11/17/2021] [Indexed: 02/03/2023]
Affiliation(s)
| | | | - Joni Beck
- The University of Oklahoma Health Science Center, Oklahoma City, OK
| | | | | | - Jo Ellen Condon
- Anne Arundel Medical Center, Annapolis, MD
- Diabetes Alliance Network, Naples, FL
| | | | | | | | | | | | | | | | - Michelle Magee
- 15MedStar Diabetes and Research Institutes, Georgetown University School of Medicine, Washington, D.C
| | - Olivia Newby
- 16The Healthy Living Center Diabetes Education Program, Norfolk, VA
| | | | | | | | | | | | - Sacha Uelmen
- 22Association of Diabetes Care & Education Specialists, Chicago, IL
| | | |
Collapse
|
7
|
Soni A, Wright N, Agwu JC, Timmis A, Drew J, Kershaw M, Moudiotis C, Regan F, Williams EC, Wan J, Ng SM. A practical approach to continuous glucose monitoring (rtCGM) and FreeStyle Libre systems (isCGM) in children and young people with Type 1 diabetes. Diabetes Res Clin Pract 2022; 184:109196. [PMID: 35033598 DOI: 10.1016/j.diabres.2022.109196] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 12/07/2021] [Accepted: 01/10/2022] [Indexed: 11/18/2022]
Abstract
Real-time continuous glucose monitoring (rtCGM) and FreeStyle Libre glucose monitoring systems (isCGM) are new evolving technologies used in the management of Type 1 diabetes. They offer potential to improve diabetes control and reduce hypoglycaemia. rtCGM can be linked to insulin pump providing hybrid closed loop therapy. Families of children and young people are keen to have the benefit from these technologies. These are relatively expensive so it is important that health care professionals, families of children and young people (CYP) with diabetes are adequately trained in the use of these devices. Health care professionals need to be able to make patient selection based on individual needs and preferences to achieve maximum benefit. Association of Children's Diabetes Clinicians (ACDC) developed a comprehensive guideline in 2017 to help identify which patients may be most likely to benefit and how these technologies may be practically implemented. Since then new technologies have been introduced and the use of GCM has expanded in routine clinical practice. This article, aims to provide a practical approach and help identify which patients may be most likely to benefit and how the technology may be implemented in order to maximise the clinical benefits.
Collapse
Affiliation(s)
- A Soni
- Sheffield Children's Hospital NHS Foundation Trust, Western Bank, Sheffield S10 2TH, United Kingdom.
| | - N Wright
- Sheffield Children's Hospital NHS Foundation Trust, Western Bank, Sheffield S10 2TH, United Kingdom
| | - J C Agwu
- Sandwell and west Birmingham Hospitals NHS Trust, United Kingdom
| | - A Timmis
- Countess of Chester Hospital NHS Foundation Trust, United Kingdom
| | - J Drew
- Nottingham University Hospitals NHS Trust, United Kingdom
| | - M Kershaw
- Birmingham Women's and Children's NHS Foundation Trust, United Kingdom
| | - C Moudiotis
- Royal Devon and Exeter NHS Foundation Trust, United Kingdom
| | - F Regan
- Frimley Health NHS Foundation Trust, United Kingdom
| | - E C Williams
- Hampshire Hospitals NHS Foundation Trust, United Kingdom
| | - Jessica Wan
- Sheffield Children's Hospital NHS Foundation Trust, Western Bank, Sheffield S10 2TH, United Kingdom
| | - S M Ng
- Southport and Ormskirk Hospital NHS Trust, United Kingdom
| |
Collapse
|
8
|
Davis J, Fischl AH, Beck J, Browning L, Carter A, Condon JE, Dennison M, Francis T, Hughes PJ, Jaime S, Lau KHK, McArthur T, McAvoy K, Magee M, Newby O, Ponder SW, Quraishi U, Rawlings K, Socke J, Stancil M, Uelmen S, Villalobos S. 2022 National Standards for Diabetes Self-Management Education and Support. Sci Diabetes Self Manag Care 2022; 48:44-59. [PMID: 35049403 DOI: 10.1177/26350106211072203] [Citation(s) in RCA: 62] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE The National Standards for Diabetes Self-Management Education and Support (DSMES) provide guidance and evidence-based, quality practice for all DSMES services. Due to the dynamic nature of health care and diabetes research, the National Standards are reviewed and revised approximately every 5 years by key stakeholders and experts within the diabetes care and education community. For each revision, the Task Force is charged with reviewing the current National Standards for appropriateness, relevance, and scientific basis and making updates based on current evidence and expert consensus. In 2021, the group was tasked with reducing administrative burden related to DSMES implementation across diverse care settings. CONCLUSION The evidence supporting the 2022 National Standards clearly identifies the need to provide person-centered services that embrace cultural differences, social determinants of health, and the ever-increasing technological engagement platforms and systems. Payers are invited to review the National Standards as a tool to inform and modernize DSMES reimbursement requirements and to align with the evolving needs of people with diabetes (PWD) and physicians/other qualified health care professionals. The American Diabetes Association and the Association of Diabetes Care & Education Specialists strongly advocate for health equity to ensure all PWD have access to this critical service proven to improve outcomes both related to and beyond diabetes. The 2022 National Standards update is meant to be a universal document that is easy to understand and can be implemented by the entire health care community. DSMES teams in collaboration with primary care have been shown to be the most effective approach to overcome therapeutic inertia.
Collapse
Affiliation(s)
| | | | - Joni Beck
- The University of Oklahoma Health Science Center, Oklahoma City, Oklahoma
| | | | | | - Jo Ellen Condon
- Anne Arundel Medical Center, Annapolis, Maryland, and Diabetes Alliance Network, Naples, Florida
| | | | | | | | - Stephen Jaime
- El Centro Regional Medical Center, El Centro, California
| | | | | | - Karen McAvoy
- Yale New Haven Health System, New Haven, Connecticut
| | - Michelle Magee
- MedStar Diabetes and Research Institutes, Georgetown University School of Medicine, Washington, DC
| | - Olivia Newby
- The Healthy Living Center Diabetes Education Program, Norfolk, Virginia
| | | | | | | | | | | | - Sacha Uelmen
- Association of Diabetes Care & Education Specialists, Chicago, Illinois
| | | |
Collapse
|
9
|
Effects of continuous subcutaneous insulin infusion on clinical parameters in patients with different sociodemographic and clinical characteristics. Int J Diabetes Dev Ctries 2021. [DOI: 10.1007/s13410-021-01025-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
10
|
Boscari F, Avogaro A. Current treatment options and challenges in patients with Type 1 diabetes: Pharmacological, technical advances and future perspectives. Rev Endocr Metab Disord 2021; 22:217-240. [PMID: 33755854 PMCID: PMC7985920 DOI: 10.1007/s11154-021-09635-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/09/2021] [Indexed: 12/14/2022]
Abstract
Type 1 diabetes mellitus imposes a significant burden of complications and mortality, despite important advances in treatment: subjects affected by this disease have also a worse quality of life-related to disease management. To overcome these challenges, different new approaches have been proposed, such as new insulin formulations or innovative devices. The introduction of insulin pumps allows a more physiological insulin administration with a reduction of HbA1c level and hypoglycemic risk. New continuous glucose monitoring systems with better accuracy have allowed, not only better glucose control, but also the improvement of the quality of life. Integration of these devices with control algorithms brought to the creation of the first artificial pancreas, able to independently gain metabolic control without the risk of hypo- and hyperglycemic crisis. This approach has revolutionized the management of diabetes both in terms of quality of life and glucose control. However, complete independence from exogenous insulin will be obtained only by biological approaches that foresee the replacement of functional beta cells obtained from stem cells: this will be a major challenge but the biggest hope for the subjects with type 1 diabetes. In this review, we will outline the current scenario of innovative diabetes management both from a technological and biological point of view, and we will also forecast some cutting-edge approaches to reduce the challenges that hamper the definitive cure of diabetes.
Collapse
Affiliation(s)
- Federico Boscari
- Department of Medicine, Unit of Metabolic Diseases, University of Padova, Padova, Italy.
| | - Angelo Avogaro
- Department of Medicine, Unit of Metabolic Diseases, University of Padova, Padova, Italy
| |
Collapse
|
11
|
Vartak V, Chepulis L, Driller M, Paul RG. Comparing Two Treatment Approaches for Patients with Type 1 Diabetes During Aerobic Exercise: a Randomised, Crossover Study. SPORTS MEDICINE - OPEN 2021; 7:29. [PMID: 33914197 PMCID: PMC8085176 DOI: 10.1186/s40798-021-00319-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Accepted: 04/08/2021] [Indexed: 11/10/2022]
Abstract
BACKGROUND In a randomised, counterbalanced, crossover design, eight men with type 1 diabetes (T1D; mean ± SD age, 27.6 ± 11.4 years) reduced insulin (INS) by 50% of their normal dose or consumed carbohydrates equivalent to 1 g of carbohydrate per kilogramme of their body weight without the usual insulin bolus (CARBS) over two sessions, held a week apart. Each session included standardised meals, a 45-min treadmill walk at 7.24 km h-1 and a 6-min walk test (6MWT). Rate of perceived exertion (RPE), blood glucose, ketone and lactate measures were taken before, during and immediately after the aerobic exercise. The distance covered in metres and the predicted VO2 max (mL kg-1 min-1) were also calculated for the 6MWT. RESULTS Participants completing the INS intervention spent more time in normoglycaemia (242 ± 135 min vs 88 ± 132 min; P < 0.01) and less time in hyperglycaemia (41 ± 95 min vs 154 ± 125 min; P = 0.01) as compared to the CARBS intervention. Mild hypoglycaemia occurred in two participants during INS and no participants during CARBS. Furthermore, there was no significant difference for blood lactate, ketone, RPE, distance covered and predicted VO2 max between interventions. CONCLUSION Based on this pilot study, INS intervention appears to be the best approach for maintaining blood glucose levels in those with T1D during aerobic exercise, though this does need evaluation in other groups, including women, children and those with suboptimal glycaemic control. TRIAL REGISTRATION Australian New Zealand Clinical Trial Registry, ACTRN12619001397101p . Registered 09 September 2019.
Collapse
Affiliation(s)
- Varun Vartak
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
| | - Lynne Chepulis
- Waikato Medical Research Centre, Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand.
| | - Matthew Driller
- Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
- Sport and Exercise, School of Allied Health, Human Services & Sport, La Trobe University, Melbourne, Australia
| | - Ryan G Paul
- Waikato Medical Research Centre, Te Huataki Waiora, School of Health, University of Waikato, Hamilton, New Zealand
- Waikato Regional Diabetes Service, Waikato District Health Board, Hamilton, New Zealand
| |
Collapse
|
12
|
Dicembrini I, Cosentino C, Monami M, Mannucci E, Pala L. Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials. Acta Diabetol 2021; 58:401-410. [PMID: 32789691 DOI: 10.1007/s00592-020-01589-3] [Citation(s) in RCA: 60] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023]
Abstract
AIMS Self-monitoring of blood glucose (SMBG) represented a major breakthrough in the treatment of type 1 diabetes. The aim of the present meta-analysis is to assess the effect of continues glucose monitoring (CGM) and flash glucose monitoring (FGM), on glycemic control in type 1 diabetes. MATERIALS AND METHODS The present analysis includes randomized clinical trials comparing CGM or FGM with SMBG, with a duration of at least 12 weeks, identified in Medline or clinicaltrials.gov. The principal endpoint was HbA1c at the end of the trial. A secondary endpoint was severe hypoglycemia. Mean and 95% confidence intervals for HbA1c and Mantel-Haenzel odds ratio [MH-OR] for severe hypoglycemia were calculated, using random effect models. A sensitivity analysis was performed using fixed effect models. In addition, the following secondary endpoints were explored, using the same methods: time in range, health-related quality of life, and treatment satisfaction. Separate analyses were performed for trials comparing CGM with SMBG, and those comparing CGM + CSII and SMBG + MDI and CGM-regulated insulin infusion system (CRIS) and CSII + SMBG. RESULTS CGM was associated with a significantly lower HbA1c at endpoint in comparison with SMBG (- 0.24 [- 0.34, - 0.13]%); CGM was associated with a significantly lower risk of severe hypoglycemia than SMBG. Treatment satisfaction and quality of life were not measured, or not reported, in the majority of studies. FGM showed a significant reduction in the incidence of mild hypoglycemia and an increased treatment satisfaction, but no significant results are shown in HbA1c. CGM + CSII in comparison with SMBG + MDI was associated with a significant reduction in HbA1c. Only two trials with a duration of at least 12 weeks compared a CRIS with SMBG + CSII; HbA1c between the two treatment arms was not statistically significant (difference in means: - 0.23 [- 0.91; 0.46]%; p = 0.52). CONCLUSION GCM compared to SMBG has showed a reduction in HbA1c and severe hypoglycemia in patient with type 1 diabetes. The comparison between CGM + CSII and SMBG + MDI showed a large reduction in HbA1c; it is conceivable that the effects of CSII + CGM on glycemic control additives. The only comparison available between FGM and SMBG was conducted in patients in good control.
Collapse
Affiliation(s)
- I Dicembrini
- Diabetology, Careggi Hospital, Florence, Italy
- University of Florence, Florence, Italy
| | - C Cosentino
- Diabetology, Careggi Hospital, Florence, Italy
| | - M Monami
- Diabetology, Careggi Hospital, Florence, Italy
| | - E Mannucci
- Diabetology, Careggi Hospital, Florence, Italy
- University of Florence, Florence, Italy
| | - L Pala
- Diabetology, Careggi Hospital, Florence, Italy.
| |
Collapse
|
13
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. Sci Diabetes Self Manag Care 2021; 47:14-29. [PMID: 34078205 DOI: 10.1177/0145721720987926] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE The purpose of this study is to review the literature for Diabetes Self-Management Education and Support (DSMES) to ensure the National Standards for DSMES (Standards) align with current evidence-based practices and utilization trends. METHODS The 10 Standards were divided among 20 interdisciplinary workgroup members. Members searched the current research for diabetes education and support, behavioral health, clinical, health care environment, technical, reimbursement, and business practice for the strongest evidence that guided the Standards revision. RESULTS Diabetes Self-Management Education and Support facilitates the knowledge, skills, and ability necessary for diabetes self-care as well as activities that assist a person in implementing and sustaining the behaviors needed to manage their condition on an ongoing basis. The evidence indicates that health care providers and people affected by diabetes are embracing technology, and this is having a positive impact of DSMES access, utilization, and outcomes. CONCLUSION Quality DSMES continues to be a critical element of care for all people with diabetes. The DSMES services must be individualized and guided by the concerns, preferences, and needs of the person affected by diabetes. Even with the abundance of evidence supporting the benefits of DSMES, it continues to be underutilized, but as with other health care services, technology is changing the way DSMES is delivered and utilized with positive outcomes.
Collapse
Affiliation(s)
- Joni Beck
- From the University of Oklahoma Health Sciences Center, College of Medicine, Oklahoma City, Oklahoma.,Technical Writer, Washington, DC (Wahowiak)
| | - Deborah A Greenwood
- Consultant, Granite Bay, California.,Technical Writer, Washington, DC (Wahowiak)
| | - Lori Blanton
- Florida Hospital, Tampa, Florida.,Technical Writer, Washington, DC (Wahowiak)
| | - Sandra T Bollinger
- Health Priorities, Cape Girardeau, Missouri.,Technical Writer, Washington, DC (Wahowiak)
| | - Marcene K Butcher
- Montana Diabetes Program, Lewistown, Montana.,Technical Writer, Washington, DC (Wahowiak)
| | - Jo Ellen Condon
- American Diabetes Association, Arlington, Virginia.,Technical Writer, Washington, DC (Wahowiak)
| | - Marjorie Cypress
- Consultant, Albuquerque, New Mexico.,Technical Writer, Washington, DC (Wahowiak)
| | - Priscilla Faulkner
- University of Northern Colorado, Fort Collins, Colorado.,Technical Writer, Washington, DC (Wahowiak)
| | - Amy Hess Fischl
- University of Chicago, Chicago, Illinois.,Technical Writer, Washington, DC (Wahowiak)
| | - Theresa Francis
- San Diego City College, San Diego, California.,Technical Writer, Washington, DC (Wahowiak)
| | - Leslie E Kolb
- American Association of Diabetes Educators, Chicago, Illinois.,Technical Writer, Washington, DC (Wahowiak)
| | | | - Janice MacLeod
- WellDoc, Columbia, Maryland.,Technical Writer, Washington, DC (Wahowiak)
| | - Melinda Maryniuk
- Joslin Diabetes Center, Boston, Massachusetts.,Technical Writer, Washington, DC (Wahowiak)
| | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, Illinois.,Technical Writer, Washington, DC (Wahowiak)
| | - Eric A Orzeck
- Endocrinology Associates, Houston, Texas.,Technical Writer, Washington, DC (Wahowiak)
| | - David D Pope
- Creative Pharmacists, Evans, Georgia.,Technical Writer, Washington, DC (Wahowiak)
| | - Jodi L Pulizzi
- Livongo, Mountain View, California.,Technical Writer, Washington, DC (Wahowiak)
| | - Ardis A Reed
- TMF Health Quality Institute, Austin, Texas.,Technical Writer, Washington, DC (Wahowiak)
| | | | - Linda Siminerio
- University of Pittsburgh Diabetes Institute, Pittsburgh, Pennsylvania.,Technical Writer, Washington, DC (Wahowiak)
| | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, Texas.,Technical Writer, Washington, DC (Wahowiak)
| |
Collapse
|
14
|
Schlüter S, Freckmann G, Heinemann L, Wintergerst P, Lange K. Evaluation of the SPECTRUM training programme for real-time continuous glucose monitoring: A real-world multicentre prospective study in 120 adults with type 1 diabetes. Diabet Med 2021; 38:e14467. [PMID: 33230860 DOI: 10.1111/dme.14467] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Revised: 11/12/2020] [Accepted: 11/14/2020] [Indexed: 12/14/2022]
Abstract
AIMS Comprehensive knowledge, specific skills and data-analysis competences are prerequisites for the successful use of continuous glucose monitoring (CGM) systems. SPECTRUM is a structured training programme for real-time CGM (rtCGM) consisting of a web-based introduction and six group sessions of 90 min each. The 'CGM-TRAIN study' evaluated the efficacy and acceptance of SPECTRUM and rtCGM systems among adults with insulin therapy. METHODS Participants (n = 120) were recruited from 10 German diabetes centres in which they were treated under usual care conditions. Outcome measures were rtCGM knowledge, practical skills, satisfaction with the training programme, satisfaction and acceptance of rtCGM system and glycaemic control. Data were collected at study entry, after training completion and at 6-month follow-up. RESULTS All participants were diagnosed with type 1 diabetes (56% women, mean age 42.4 ± 13.4 years, diabetes duration 21.6 ± 11.6 years), 110 participants completed the course. After training completion, rtCGM-specific knowledge had improved by 43% (scale: 0-40 points) from 21.2 ± 7.6 to 30.4 ± 4.5 points; p < 0.001. The knowledge-level persisted until follow-up (29.4 ± 4.5). Participants were able to master nearly all the practical requirements of the technology. In addition, rtCGM was highly accepted, and participants were motivated to use their systems continuously. HbA1c improved slightly from 61 ± 14 mmol/mol (7.7 ± 1.3%) before training to 60 ± 14 mmol/mol (7.6 ± 1.3%) at follow-up (p = 0.04). The training programme itself was favourably rated by participants. CONCLUSIONS Under usual out-patient daily care conditions, the training programme SPECTRUM improved knowledge and skills about rtCGM in adults with type 1 diabetes. This was associated with a reduced HbA1c , high satisfaction and acceptance of rtCGM (Clinical Trials Registry no.: DRKS00014380).
Collapse
Affiliation(s)
- Sandra Schlüter
- Diabetesschwerpunktpraxis Northeim, Northeim, Germany
- Hannover Medical School - Medical Psychology, Hannover, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | | | - Peter Wintergerst
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Karin Lange
- Hannover Medical School - Medical Psychology, Hannover, Germany
| |
Collapse
|
15
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. DIABETES EDUCATOR 2019; 46:46-61. [PMID: 31874594 DOI: 10.1177/0145721719897952] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE The purpose of this study is to review the literature for Diabetes Self-Management Education and Support (DSMES) to ensure the National Standards for DSMES (Standards) align with current evidence-based practices and utilization trends. METHODS The 10 Standards were divided among 20 interdisciplinary workgroup members. Members searched the current research for diabetes education and support, behavioral health, clinical, health care environment, technical, reimbursement, and business practice for the strongest evidence that guided the Standards revision. RESULTS Diabetes Self-Management Education and Support facilitates the knowledge, skills, and ability necessary for diabetes self-care as well as activities that assist a person in implementing and sustaining the behaviors needed to manage their condition on an ongoing basis. The evidence indicates that health care providers and people affected by diabetes are embracing technology, and this is having a positive impact of DSMES access, utilization, and outcomes. CONCLUSION Quality DSMES continues to be a critical element of care for all people with diabetes. The DSMES services must be individualized and guided by the concerns, preferences, and needs of the person affected by diabetes. Even with the abundance of evidence supporting the benefits of DSMES, it continues to be underutilized, but as with other health care services, technology is changing the way DSMES is delivered and utilized with positive outcomes.
Collapse
Affiliation(s)
- Joni Beck
- University of Oklahoma Health Sciences Center, College of Medicine, Oklahoma City, Oklahoma
| | | | | | | | | | | | | | | | | | | | - Leslie E Kolb
- American Association of Diabetes Educators, Chicago, Illinois
| | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, Illinois
| | | | | | | | | | | | - Linda Siminerio
- University of Pittsburgh Diabetes Institute, Pittsburgh, Pennsylvania
| | - Jing Wang
- University of Texas Health Science Center at Houston, Houston, Texas.,Technical Writer, Washington, DC
| |
Collapse
|
16
|
Ravizza A, De Maria C, Di Pietro L, Sternini F, Audenino AL, Bignardi C. Comprehensive Review on Current and Future Regulatory Requirements on Wearable Sensors in Preclinical and Clinical Testing. Front Bioeng Biotechnol 2019; 7:313. [PMID: 31781554 PMCID: PMC6857326 DOI: 10.3389/fbioe.2019.00313] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Accepted: 10/23/2019] [Indexed: 11/13/2022] Open
Abstract
Medical devices are designed, tested, and placed on the market in a highly regulated environment. Wearable sensors are crucial components of various medical devices: design and validation of wearable sensors, if managed according to international standards, can foster innovation while respecting regulatory requirements. The purpose of this paper is to review the upcoming European Union (EU) Medical Device Regulations 2017/745 and 2017/746, the current and future International Electrotechnical Commission (IEC) and International Organization for Standardization (ISO) standards that set methods for design and validation of medical devices, with a focus on wearable sensors. Risk classification according to the regulation is described. The international standards IEC 62304, IEC 60601, ISO 14971, and ISO 13485 are reviewed to define regulatory restrictions during design, pre-clinical validation and clinical validation of devices that include wearable sensors as crucial components. This paper is not about any specific innovation but it is a toolbox for interpreting current and future regulatory restrictions; an integrated method for design planning, validation and clinical testing is proposed. Application of this method to design wearable sensors should be evaluated in the future in order to assess its potentially positive impact to fostering innovation and to ensure timely development.
Collapse
Affiliation(s)
| | - Carmelo De Maria
- Information Engineering Department, Research Center "Enrico Piaggio", University of Pisa, Pisa, Italy
| | - Licia Di Pietro
- Information Engineering Department, Research Center "Enrico Piaggio", University of Pisa, Pisa, Italy
| | - Federico Sternini
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Alberto L Audenino
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Cristina Bignardi
- PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
17
|
Wan W, Skandari MR, Minc A, Nathan AG, Zarei P, Winn AN, O'Grady M, Huang ES. Cost-effectiveness of Initiating an Insulin Pump in T1D Adults Using Continuous Glucose Monitoring Compared with Multiple Daily Insulin Injections: The DIAMOND Randomized Trial. Med Decis Making 2019; 38:942-953. [PMID: 30403576 DOI: 10.1177/0272989x18803109] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
BACKGROUND The economic impact of both continuous glucose monitoring (CGM) and insulin pumps (continuous subcutaneous insulin infusion [CSII]) in type 1 diabetes (T1D) have been evaluated separately. However, the cost-effectiveness of adding CSII to existing CGM users has not yet been assessed. OBJECTIVE The aim of this study was to evaluate the societal cost-effectiveness of CSII versus continuing multiple daily injections (MDI) in adults with T1D already using CGM. METHODS In the second phase of the DIAMOND trial, 75 adults using CGM were randomized to either CGM+CSII or CGM+MDI (control) and surveyed at baseline and 28 weeks. We performed within-trial and lifetime cost-effectiveness analyses (CEAs) and estimated lifetime costs and quality-adjusted life-years (QALYs) via a modified Sheffield T1D model. RESULTS Within the trial, the CGM+CSII group had a significant reduction in quality of life from baseline (-0.02 ± 0.05 difference in difference [DiD]) compared with controls. Total per-person 28-week costs were $8,272 (CGM+CSII) versus $5,623 (CGM+MDI); the difference in costs was primarily attributable to pump use ($2,644). Pump users reduced insulin intake (-12.8 units DiD) but increased the use of daily number of test strips (+1.2 DiD). Pump users also increased time with glucose in range of 70 to 180 mg/dL but had a higher HbA1c (+0.13 DiD) and more nonsevere hypoglycemic events. In the lifetime CEA, CGM+CSII would increase total costs by $112,045 DiD, decrease QALYs by 0.71, and decrease life expectancy by 0.48 years. CONCLUSIONS Based on this single trial, initiating an insulin pump in adults with T1D already using CGM was associated with higher costs and reduced quality of life. Additional evidence regarding the clinical effects of adopting combinations of new technologies from trials and real-world populations is needed to confirm these findings.
Collapse
Affiliation(s)
- Wen Wan
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - M Reza Skandari
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Alexa Minc
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Aviva G Nathan
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Parmida Zarei
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Aaron N Winn
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Michael O'Grady
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| | - Elbert S Huang
- Section of General Internal Medicine, University of Chicago, Chicago, IL (WW, MRS, AM, AGN, PZ, ESH).,School of Pharmacy, Medical College of Wisconsin, Milwaukee, WI (ANW).,National Opinion Research Center, University of Chicago, Chicago, IL (MO)
| |
Collapse
|
18
|
Sørgård B, Iversen MM, Mårtensson J. Continuous glucose monitoring in adults with type 1 diabetes: A balance between benefits and barriers: A critical incident study. J Clin Nurs 2019; 28:3318-3329. [PMID: 31090960 DOI: 10.1111/jocn.14911] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Revised: 03/12/2019] [Accepted: 04/14/2019] [Indexed: 01/22/2023]
Abstract
AIMS AND OBJECTIVES To describe positively and negatively perceived situations experienced by adults with type 1 diabetes using continuous glucose monitoring and the actions they take to deal with these situations. BACKGROUND Real-time continuous glucose monitoring has been shown to improve glycaemic control and reduce hypoglycaemia. Although many patients with type 1 diabetes report great benefits when using continuous glucose monitoring, a substantial number discontinue using the device. Little is known about the different situations and experiences with the daily use of continuous glucose monitoring that contribute to such differences. DESIGN A descriptive design based on the critical incident technique was used. The study complied with the Consolidated Criteria for Reporting Qualitative Research (COREQ) (see File S1). METHODS Individual interviews were conducted with a purposive sample of 23 adults with type 1 diabetes, including current and former users of continuous glucose monitoring from four different outpatient clinics. RESULTS The participants described that they felt that the use of continuous glucose monitoring was a balance between benefits and barriers, and how, through their actions, they tried to adapt their use of continuous glucose monitoring to fit their lifestyles. Various life events affected and altered the balance between benefits and barriers and thus affected their use of continuous glucose monitoring. CONCLUSIONS Continuous glucose monitoring is perceived as an effective and important tool in the self-management of diabetes type 1. It enables a better everyday life and increased satisfaction with treatment. At the same time, the use of continuous glucose monitoring can be both demanding and challenging. RELEVANCE TO CLINICAL PRACTICE Understanding the complex interplay between perceived benefits, treatment burden and adherence to continuous glucose monitoring use is important for nurses engaged in diabetes care. Education and support regarding the use of continuous glucose monitoring must be based on the understanding and perspectives of the patient to alleviate stress and barriers and enhance self-efficacy. As the use of continuous glucose monitoring can change over time, this must be a continuous process beyond initial training.
Collapse
Affiliation(s)
- Beate Sørgård
- Department of Health and Caring Sciences, Faculty of Health and Social Science, Western University of Applied Sciences, Bergen, Norway.,Department of Medicine, Vestre Viken, Baerum Hospital, Oslo, Norway
| | - Marjolein M Iversen
- Department of Health and Caring Sciences, Faculty of Health and Social Science, Western University of Applied Sciences, Bergen, Norway
| | - Jan Mårtensson
- Department of Health and Caring Sciences, Faculty of Health and Social Science, Western University of Applied Sciences, Bergen, Norway.,Department of Nursing, School of Health and Welfare, Western Norway University of Applied Sciences, Bergen, Norway
| |
Collapse
|
19
|
Sumnik Z, Szypowska A, Iotova V, Bratina N, Cherubini V, Forsander G, Jali S, Raposo JF, Stipančic G, Vazeou A, Veeze H, Lange K. Persistent heterogeneity in diabetes technology reimbursement for children with type 1 diabetes: The SWEET perspective. Pediatr Diabetes 2019; 20:434-443. [PMID: 30773756 DOI: 10.1111/pedi.12833] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 10/25/2018] [Accepted: 01/28/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Frequent use of modern diabetes technologies increases the chance for optimal type 1 diabetes (T1D) control. Limited reimbursement influences the access of patients with T1D to these modalities and could worsen their prognosis. We aimed to describe the situation of reimbursement for insulins, glucometers, insulin pumps (CSII) and continuous glucose monitoring (CGM) for children with T1D in European countries participating in the SWEET Project and to compare data from EU countries with data from our previous study in 2009. METHODS The study was conducted between March 2017 and August 2017. First, we approached diabetes technology companies with a survey to map the reimbursement of insulins and diabetic devices. The data collected from these companies were then validated by members of the SWEET consortium. RESULTS We collected data from 29 European countries, whereas all types of insulins are mostly fully covered, heterogeneity was observed regarding the reimbursement of strips for glucometers (from 90 strips/month to no limit). CSII is readily available in 20 of 29 countries. Seven countries reported significant quota issues or obstacles for CSII prescription, and two countries had no CSII reimbursement. CGM is at least partially reimbursed in 17 of 29 countries. The comparison with the 2009 study showed an increasing availability of CSII and CGM across the EU. CONCLUSIONS Although innovative diabetes technology is available, a large proportion of children with T1D still do not benefit from it due to its limited reimbursement.
Collapse
Affiliation(s)
- Zdenek Sumnik
- Department of Pediatrics, Motol University Hospital, Prague, Czech Republic
| | | | - Violeta Iotova
- Department of Pediatrics, Medical University-Varna, UMHAT "Sv. Marina", Varna, Bulgaria
| | - Natasa Bratina
- Department of Endocrinology, Diabetes and Metabolism, UMC, University Children's Hospital, Ljubljana, Slovenia
| | - Valentino Cherubini
- Department of Women's and Children's Health, Azienda Ospedaliero-Universitaria, Ospedali Riuniti di Ancona, "G. Salesi" Hospital, Ancona, Italy
| | - Gun Forsander
- Institute for Clinical Sciences, Dept of Ped, University of Gothenburg and the Queen Silvia Children's Hospital, Sahlgrenska Univ. Hospital, Gothenburg, Sweden
| | - Sujata Jali
- Department of Pediatrics, KLE University's Jawaharlal Nehru Medical College Belgaum, Belgaum, India
| | | | - Gordana Stipančic
- Department of Pediatrics, University Hospital Center "Sestre milosrdnice", School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Andriani Vazeou
- Department of Pediatrics, Diabetes Center, P & A Kyriakou Children's Hospital, Athens, Greece
| | | | - Karin Lange
- Department of Medical Psychology, Hannover Medical School, Hannover, Germany
| | | |
Collapse
|
20
|
Clinical efficacy of Professional Continuous Glucose Monitoring in improving glycemic control among children with Type 1 Diabetes Mellitus: An Open-label Randomized Control Trial. Sci Rep 2019; 9:6120. [PMID: 30992480 PMCID: PMC6467868 DOI: 10.1038/s41598-019-42555-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 03/04/2019] [Indexed: 01/08/2023] Open
Abstract
Frequent self-monitoring of blood glucose (SMBG) is the only accurate method available for insulin dose titration in patients with T1DM. Professional continuous glucose monitoring (p-CGM) is blinded recording of glucose trends over 5–7 days and helps physicians to guide insulin titration to patient. This study was planned to assess efficacy of insulin dose adjustments, based on p-CGM plus SMBG in improving glycemic control compared to SMBG alone. We did an open-label, parallel design, randomized control trial among children (2–10 years) having T1DM for at least 6 months. Subjects in the intervention group were placed on p-CGM (iPRO 2™ Professional CGM, Medtronic, USA) for 3–5 days along with regular SMBG. Data from p-CGM was analyzed by physician and used to guide insulin titration along with SMBG over following 3 months. Control group had only SMBG records for titrating insulin doses. Primary outcome was change in HbA1c 3 months after intervention. A total of 68 eligible children were randomized, 34 each to either arms. Thirty children in intervention group and 33 in control group completed the study and were analyzed. It was found that there was more decreased unit change in HbA1c, percentage of low sugar records and total insulin requirement per day, after 3 months follow-up, in intervention group. However, difference was not significant except for total insulin Units/kg/day (p = 0.014). In sub-group analysis of children with baseline HbA1c >7.5%, there was a significant mean fall of HbA1c by 1.27% (p = 0.045). There were no major adverse events associated with p-CGM. We conclude that addition of p-CGM along with SMBG may help in adjusting insulin dose more effectively especially in children with higher baseline HbA1c.
Collapse
|
21
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. DIABETES EDUCATOR 2018; 45:34-49. [PMID: 30558523 DOI: 10.1177/0145721718820941] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE The purpose of this study is to review the literature for Diabetes Self-Management Education and Support (DSMES) to ensure the National Standards for DSMES (Standards) align with current evidence-based practices and utilization trends. METHODS The 10 Standards were divided among 20 interdisciplinary workgroup members. Members searched the current research for diabetes education and support, behavioral health, clinical, health care environment, technical, reimbursement, and business practice for the strongest evidence that guided the Standards revision. RESULTS Diabetes Self-Management Education and Support facilitates the knowledge, skills, and ability necessary for diabetes self-care as well as activities that assist a person in implementing and sustaining the behaviors needed to manage their condition on an ongoing basis. The evidence indicates that health care providers and people affected by diabetes are embracing technology, and this is having a positive impact of DSMES access, utilization, and outcomes. CONCLUSION Quality DSMES continues to be a critical element of care for all people with diabetes. The DSMES services must be individualized and guided by the concerns, preferences, and needs of the person affected by diabetes. Even with the abundance of evidence supporting the benefits of DSMES, it continues to be underutilized, but as with other health care services, technology is changing the way DSMES is delivered and utilized with positive outcomes.
Collapse
Affiliation(s)
- Joni Beck
- University of Oklahoma Health Sciences Center, College of Medicine, Oklahoma City, Oklahoma
| | | | | | | | | | | | | | | | | | | | - Leslie E Kolb
- American Association of Diabetes Educators, Chicago, Illinois
| | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, Illinois
| | | | | | | | | | | | - Linda Siminerio
- University of Pittsburgh Diabetes Institute, Pittsburgh, Pennsylvania
| | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, Texas
- Technical Writer, Washington, DC
| |
Collapse
|
22
|
Desai D, Mehta D, Mathias P, Menon G, Schubart UK. Health Care Utilization and Burden of Diabetic Ketoacidosis in the U.S. Over the Past Decade: A Nationwide Analysis. Diabetes Care 2018; 41:1631-1638. [PMID: 29773640 DOI: 10.2337/dc17-1379] [Citation(s) in RCA: 122] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2017] [Accepted: 04/27/2018] [Indexed: 02/03/2023]
Abstract
OBJECTIVE Diabetes is one of the most common chronic diseases and a leading cause of morbidity and mortality in the U.S. Although our ability to treat diabetes and its associated complications has significantly improved, presentation with uncontrolled diabetes leading to ketoacidosis remains a significant problem. RESEARCH DESIGN AND METHODS We aimed to determine the incidence and costs of hospital admissions associated with diabetic ketoacidosis (DKA). We reviewed the National Inpatient Sample database for all hospitalizations in which DKA (ICD-9 codes 250.10, 250.11, 250.12, and 250.13) was the principal discharge diagnosis during 2003-2014 and calculated the population incidence by using U.S. census data. Patients with ICD-9 codes for diabetic coma were excluded because the codes do not distinguish between hypoglycemic and DKA-related coma. We then analyzed changes in temporal trends of incidence, length of stay, costs, and in-hospital mortality by using the Cochrane-Armitage test. RESULTS There were 1,760,101 primary admissions for DKA during the study period. In-hospital mortality for the cohort was 0.4% (n = 7,031). The total number of hospital discharges with the principal diagnosis of DKA increased from 118,808 in 2003 to 188,965 in 2014 (P < 0.0001). The length of stay significantly decreased from an average of 3.64 days in 2003 to 3.24 days in 2014 (P < 0.01). During this period, the mean hospital charges increased significantly from $18,987 (after adjusting for inflation) per admission in 2003 to $26,566 per admission in 2014. The resulting aggregate charges (i.e., national bill) for diabetes with ketoacidosis increased dramatically from $2.2 billion (after adjusting for inflation) in 2003 to $ 5.1 billion in 2014 (P < 0.001). However, there was a significant reduction in mortality from 611 (0.51%) in 2003 to 620 (0.3%) in 2014 (P < 0.01). CONCLUSIONS Our analysis shows that the population incidence for DKA hospitalizations in the U.S. continues to increase, but the mortality from this condition has significantly decreased, indicating advances in early diagnosis and better inpatient care. Despite decreases in the length of stay, the costs of hospitalizations have increased significantly, indicating opportunities for value-based care intervention in this vulnerable population.
Collapse
Affiliation(s)
- Dimpi Desai
- Department of Medicine, Jacobi Medical Center/Albert Einstein College of Medicine, Bronx, NY
| | - Dhruv Mehta
- Division of Gastroenterology and Hepatobiliary Diseases, Westchester Medical Center and New York Medical College, Valhalla, NY
| | - Priyanka Mathias
- Department of Medicine, Jacobi Medical Center/Albert Einstein College of Medicine, Bronx, NY
| | - Gopal Menon
- Department of Global Health and Social Medicine, Harvard T.H. Chan School of Public Health, Boston, MA
| | - Ulrich K Schubart
- Department of Medicine, Jacobi Medical Center/Albert Einstein College of Medicine, Bronx, NY
| |
Collapse
|
23
|
Souto DL, Dantas JR, Oliveira MMDS, Rosado EL, Luiz RR, Zajdenverg L, Rodacki M. Does sucrose affect the glucose variability in patients with type 1 diabetes? a pilot crossover clinical study. Nutrition 2018; 55-56:179-184. [PMID: 30086487 DOI: 10.1016/j.nut.2018.05.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 05/26/2018] [Accepted: 05/28/2018] [Indexed: 10/14/2022]
Abstract
OBJECTIVE The aim of this study was to compare the effects of a sucrose-free diet with a sucrose-added diet on glucose variability in patients with type 1 diabetes. METHODS This was a two-way crossover design study in which patients with type 1 diabetes were monitored by blinded continuous glucose monitoring and were selected to receive a sucrose-free diet (<30 g/d), followed by a sucrose-added diet (>80 g/d) for 2 d each. Intra-day glucose variability was assessed by the mean amplitude of glycemic excursions (MAGE), the M-value, J-index, glycemic risk assessment in diabetes equation (GRADE), and continuous overlapping net glycemic action (CONGA1-3). Between-day variability was determined by mean of daily difference (MODD). Statistical analyses were performed with a significance level of 5%. RESULTS Ten patients with type 1 diabetes were evaluated. The participants were a mean of 26.1 ± 7.1 y of age. The mean duration of disease was 16.5 ± 10.5 y, and patients' mean glycated hemoglobin was 7.4% ± 0.8%. The intra- and inter-day glucose variability indexes did not differ between the diet periods (MAGE: 10.2 ± 5.1 and 10.4 ± 6.8mmol/L, P = 0.98; M-value: 12.9 ± 2 and 15.6 ± 1.3mmol/L, P = 0.29; J-index: 50.9 ± 4.4 and 57.7 ± 3.3mmol/L, P = 0.41; GRADE: 7.2 ± 1 and 4.7 ± 5.3mmol/L, P = 0.07; and MODD: 3.9 ± 1 and 4.3 ± 1.5mmol/L, P = 0.28; for the sucrose-free and sucrose-added diets, respectively). CONGA1-3 were similar for both diet periods (P > 0.05). CONCLUSIONS The use of a moderate amount of sucrose, as part of a balanced diet, did not affect the glucose variability or insulin requirements in patients with type 1 diabetes.
Collapse
Affiliation(s)
- Débora Lopes Souto
- Department of Internal Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil; Institute of Nutrition Josué de Castro, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil.
| | - Joana Rodrigues Dantas
- Department of Internal Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | | | - Eliane Lopes Rosado
- Institute of Nutrition Josué de Castro, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Ronir Raggio Luiz
- Institute of Public Health Studies, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Lenita Zajdenverg
- Department of Internal Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Melanie Rodacki
- Department of Internal Medicine, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| |
Collapse
|
24
|
Picard S, Hanaire H, Reznik Y, Benhamou PY, Fendri S, Dufaitre L, Leutenegger E, Guerci B. Optimization of Insulin Regimen and Glucose Outcomes with Short-Term Real-Time Continuous Glucose Monitoring in Adult Type 1 Diabetes Patients with Suboptimal Control on Multiple Daily Injections: The Adult DIACCOR Study. Diabetes Technol Ther 2018; 20:403-412. [PMID: 29847735 DOI: 10.1089/dia.2018.0002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND The impact of a 7-day real-time continuous glucose monitoring (RT-CGM) on type 1 diabetes (T1D) management remains unclear in patients suboptimally controlled by multiple daily injections (MDI). The DIACCOR Study aimed to describe treatment decisions and glucose outcomes after a short-term RT-CGM sequence. PATIENTS AND METHODS This French multicenter longitudinal observational study included T1D patients with HbA1c >7.5% or history of severe hypoglycemia (SH) or recurrent documented hypoglycemia. A sensor was inserted at the inclusion visit, treatment changes were proposed by the investigator within 7-15 days ("INT" = MDI intensification, "CSII" = switch to continuous insulin infusion, or "ER" = educational reinforcement with no change in insulin regimen), and a 4-month follow-up visit (M4) was scheduled. RESULTS Four hundred fifty-nine patients were recruited by 155 diabetologists, 17.0% had SH history, and 24.2% had recurrent hypoglycemia. Baseline HbA1c was 8.34% ± 1.21% (>7.5% in 79.6%). Overall, 253 (64.4%), 64 (16.3%), and 76 patients (19.3%) were, respectively, included in the "INT," "CSII," and "ER" subgroups. The number of patients who experienced SH or recurrent hypoglycemia dropped dramatically (7.9% vs. 17.0% and 10.8% vs. 24.2%, respectively). The same trend was observed for ketoacidosis and ketosis (0.3% vs. 3.3% and 2.2% vs. 4.8%). At M4, HbA1c was significantly reduced in the whole cohort to 7.98% ± 1.01% (P < 0.0001). The adjusted differences in HbA1c level in the INT, CSII, and ER subgroups were, respectively, -0.32%, -0.69%, and -0.50% (P < 0.0001 for all). CONCLUSION In real-life setting, a 1-week diagnostic RT-CGM supports appropriate treatment changes in patients with uncontrolled T1D resulting in better glucose control and less hypoglycemia.
Collapse
Affiliation(s)
- Sylvie Picard
- 1 Point Médical, Rond-Point de la Nation , Dijon, France
| | - Hélène Hanaire
- 2 Endocrinology-Diabetes Care Unit, Toulouse University Hospital , Toulouse, France
| | - Yves Reznik
- 3 Endocrinology-Diabetes Care Unit, Caen University Hospital , Caen, France
| | - Pierre-Yves Benhamou
- 4 Endocrinology-Diabetes Care Unit, Grenoble University Hospital , Grenoble, France
| | - Salha Fendri
- 5 Endocrinology-Diabetes Care Unit, Amiens University Hospital , Amiens, France
| | - Lise Dufaitre
- 6 Endocrinology-Diabetes Care Unit, Marseille University Hospital , Marseille, France
| | | | - Bruno Guerci
- 8 Endocrinology, Diabetology and Nutrition, Brabois Adult Hospital CHRU of Nancy, University of Lorraine , Vandoeuvre Lès Nancy, France
| |
Collapse
|
25
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. DIABETES EDUCATOR 2018; 44:35-50. [DOI: 10.1177/0145721718754797] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Purpose The purpose of this study is to review the literature for Diabetes Self-Management Education and Support (DSMES) to ensure the National Standards for DSMES (Standards) align with current evidence-based practices and utilization trends. Methods The 10 Standards were divided among 20 interdisciplinary workgroup members. Members searched the current research for diabetes education and support, behavioral health, clinical, health care environment, technical, reimbursement, and business practice for the strongest evidence that guided the Standards revision. Results Diabetes Self-Management Education and Support facilitates the knowledge, skills, and ability necessary for diabetes self-care as well as activities that assist a person in implementing and sustaining the behaviors needed to manage their condition on an ongoing basis. The evidence indicates that health care providers and people affected by diabetes are embracing technology, and this is having a positive impact of DSMES access, utilization, and outcomes. Conclusion Quality DSMES continues to be a critical element of care for all people with diabetes. The DSMES services must be individualized and guided by the concerns, preferences, and needs of the person affected by diabetes. Even with the abundance of evidence supporting the benefits of DSMES, it continues to be underutilized, but as with other health care services, technology is changing the way DSMES is delivered and utilized with positive outcomes.
Collapse
Affiliation(s)
- Joni Beck
- University of Oklahoma Health Sciences Center, College of Medicine, Oklahoma City, Oklahoma
| | | | | | | | | | | | | | | | | | | | - Leslie E. Kolb
- American Association of Diabetes Educators, Chicago, Illinois
| | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, Illinois
| | | | | | | | | | | | - Linda Siminerio
- University of Pittsburgh Diabetes Institute, Pittsburgh, Pennsylvania
| | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, Texas
- Technical Writer, Washington, DC (Wahowiak)
| |
Collapse
|
26
|
Petrie JR, Peters AL, Bergenstal RM, Holl RW, Fleming GA, Heinemann L. Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations: A Joint Statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group. Diabetes Care 2017; 40:1614-1621. [PMID: 29070577 DOI: 10.2337/dci17-0043] [Citation(s) in RCA: 97] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionize the use of intensive insulin therapy in diabetes; however, progress toward that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardized format for displaying results, and uncertainty on how best to use CGM data to make therapeutic decisions. This Scientific Statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes.
Collapse
Affiliation(s)
- John R Petrie
- Institute of Cardiovascular & Medical Sciences, University of Glasgow, Glasgow, U.K.
| | - Anne L Peters
- Keck School of Medicine of the University of Southern California, Los Angeles, CA
| | | | - Reinhard W Holl
- Institute of Epidemiology and Medical Biometry, University of Ulm, Ulm, Germany
| | | | | |
Collapse
|
27
|
Petrie JR, Peters AL, Bergenstal RM, Holl RW, Fleming GA, Heinemann L. Improving the clinical value and utility of CGM systems: issues and recommendations : A joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group. Diabetologia 2017; 60:2319-2328. [PMID: 29067486 DOI: 10.1007/s00125-017-4463-4] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Accepted: 08/23/2017] [Indexed: 01/22/2023]
Abstract
The first systems for continuous glucose monitoring (CGM) became available over 15 years ago. Many then believed CGM would revolutionise the use of intensive insulin therapy in diabetes; however, progress towards that vision has been gradual. Although increasing, the proportion of individuals using CGM rather than conventional systems for self-monitoring of blood glucose on a daily basis is still low in most parts of the world. Barriers to uptake include cost, measurement reliability (particularly with earlier-generation systems), human factors issues, lack of a standardised format for displaying results and uncertainty on how best to use CGM data to make therapeutic decisions. This scientific statement makes recommendations for systemic improvements in clinical use and regulatory (pre- and postmarketing) handling of CGM devices. The aim is to improve safety and efficacy in order to support the advancement of the technology in achieving its potential to improve quality of life and health outcomes for more people with diabetes.
Collapse
Affiliation(s)
- John R Petrie
- Institute of Cardiovascular and Medical Sciences, University of Glasgow, 126 University Place, Glasgow, G12 8TA, UK.
| | - Anne L Peters
- Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | | | - Reinhard W Holl
- Institute of Epidemiology and Medical Biometry, ZIBMT, University of Ulm, Ulm, Germany
| | | | | |
Collapse
|
28
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. Diabetes Spectr 2017; 30:301-314. [PMID: 29151721 PMCID: PMC5687107 DOI: 10.2337/ds17-0067] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
This article was copublished in Diabetes Care 2017;40:1409-1419 and The Diabetes Educator 2017;43:449-464 and is reprinted with permission. The previous version of this article, also copublished in Diabetes Care and The Diabetes Educator, can be found at Diabetes Care 2012;35:2393-2401 (https://doi.org/10.2337/dc12-1707).
Collapse
Affiliation(s)
- Joni Beck
- College of Medicine, University of Oklahoma Health Sciences Center, Oklahoma City, OK
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, IL
| | | | | | | | | | | | | | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, TX
| |
Collapse
|
29
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. Diabetes Care 2017; 40:1409-1419. [PMID: 28754780 DOI: 10.2337/dci17-0025] [Citation(s) in RCA: 192] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Affiliation(s)
- Joni Beck
- College of Medicine, University of Oklahoma Health Sciences Center, Oklahoma City, OK
| | | | | | | | | | | | | | | | | | | | - Leslie E Kolb
- American Association of Diabetes Educators, Chicago, IL
| | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, IL
| | | | | | | | | | | | | | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, TX
| | | |
Collapse
|
30
|
Beck J, Greenwood DA, Blanton L, Bollinger ST, Butcher MK, Condon JE, Cypress M, Faulkner P, Fischl AH, Francis T, Kolb LE, Lavin-Tompkins JM, MacLeod J, Maryniuk M, Mensing C, Orzeck EA, Pope DD, Pulizzi JL, Reed AA, Rhinehart AS, Siminerio L, Wang J. 2017 National Standards for Diabetes Self-Management Education and Support. DIABETES EDUCATOR 2017; 43:449-464. [PMID: 28753378 DOI: 10.1177/0145721717722968] [Citation(s) in RCA: 106] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Purpose The purpose of this study is to review the literature for Diabetes Self-Management Education and Support (DSMES) to ensure the National Standards for DSMES (Standards) align with current evidence-based practices and utilization trends. Methods The 10 Standards were divided among 20 interdisciplinary workgroup members. Members searched the current research for diabetes education and support, behavioral health, clinical, health care environment, technical, reimbursement, and business practice for the strongest evidence that guided the Standards revision. Results Diabetes Self-Management Education and Support facilitates the knowledge, skills, and ability necessary for diabetes self-care as well as activities that assist a person in implementing and sustaining the behaviors needed to manage their condition on an ongoing basis. The evidence indicates that health care providers and people affected by diabetes are embracing technology, and this is having a positive impact of DSMES access, utilization, and outcomes. Conclusion Quality DSMES continues to be a critical element of care for all people with diabetes. The DSMES services must be individualized and guided by the concerns, preferences, and needs of the person affected by diabetes. Even with the abundance of evidence supporting the benefits of DSMES, it continues to be underutilized, but as with other health care services, technology is changing the way DSMES is delivered and utilized with positive outcomes.
Collapse
Affiliation(s)
- Joni Beck
- University of Oklahoma Health Sciences Center, College of Medicine, Oklahoma City, Oklahoma (Dr Beck)
| | | | | | | | | | - Jo Ellen Condon
- American Diabetes Association, Arlington, Virginia (Ms Condon)
| | | | | | | | | | - Leslie E Kolb
- American Association of Diabetes Educators, Chicago, Illinois (Ms Kolb)
| | | | | | | | - Carolé Mensing
- National Certification Board for Diabetes Educators, Arlington Heights, Illinois (Mensing)
| | | | | | | | - Ardis A Reed
- TMF Health Quality Initiative, Austin, Texas (Reed)
| | | | - Linda Siminerio
- University of Pittsburgh Diabetes Institute, Pittsburgh, Pennsylvania (Siminerio)
| | - Jing Wang
- The University of Texas Health Science Center at Houston, Houston, Texas (Wang)
| | | |
Collapse
|
31
|
Abstract
Real-time continuous glucose monitoring has been available for a decade and reimbursement for the technology has been slowly growing. Reasons for the various rates of reimbursement and adoption are explored in this article and the status of country-wide reimbursement is discussed.
Collapse
|
32
|
Giani E, Snelgrove R, Volkening LK, Laffel LM. Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables. J Diabetes Sci Technol 2017; 11:476-483. [PMID: 27807014 PMCID: PMC5505422 DOI: 10.1177/1932296816676280] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) remains underutilized in youth with type 1 diabetes (T1D). There is a need to investigate factors associated with CGM use. METHOD In 61 T1D youth, CGM use was ascertained by downloads reflecting the 4-week periods preceding 3- and 6-month study visits. Demographic and clinical data were obtained from chart review and interview. Youth and parents completed validated psychosocial surveys at baseline and 6 months. RESULTS Youth (52% male, 93% Caucasian, 80% pump treated) were 12.7 ± 2.9 years old, with T1D for 6.3 ± 3.8 years; mean A1c was 7.9 ± 0.9%. Mean CGM use was 4.1 ± 2.1 days/week (median = 4.8) at 3 months and 3.4 ± 2.3 days/week (median = 3.9) at 6 months. At 3 and 6 months, 15% and 20% of youth, respectively, had stopped using CGM. At 6 months, youth using CGM 6-7 days/week had more frequent BG monitoring ( P = .05), less insulin omission ( P = .02), and greater probability of A1c < 7.5% ( P = .01) than youth using CGM less often. Youth using CGM 6-7 days/week consistently over the 6 months demonstrated lower A1c at 3 months compared to baseline ( P = .03) and the improvement was sustained at 6 months ( P = .5, 3 vs 6 months); youth using CGM less often had no significant A1c change. Baseline BG monitoring ≥8 times/day or A1c within target (<7.5%) predicted greater CGM use (6-7 days/week) at 6 months (OR = 4.6, P = .02). There was no deterioration of psychosocial functioning with CGM use. CONCLUSIONS Consistent and durable CGM use in youth with T1D is associated with treatment adherence and improved glycemic control without increasing psychosocial distress.
Collapse
Affiliation(s)
- Elisa Giani
- Pediatric, Adolescent and Young Adult Section, Section on Clinical, Behavioral and Outcomes Research, Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
- Department of Pediatrics, Section on Pediatric Endocrinology, Diabetes and Metabolism, Biomedical and Clinical Science Department, V. Buzzi Children’s Hospital, University of Milan, Milan, Italy
| | - Rebecca Snelgrove
- Pediatric, Adolescent and Young Adult Section, Section on Clinical, Behavioral and Outcomes Research, Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
| | - Lisa K. Volkening
- Pediatric, Adolescent and Young Adult Section, Section on Clinical, Behavioral and Outcomes Research, Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
| | - Lori M. Laffel
- Pediatric, Adolescent and Young Adult Section, Section on Clinical, Behavioral and Outcomes Research, Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
- Lori M. Laffel, MD, MPH, Joslin Diabetes Center, One Joslin Place, Boston, MA 02215, USA.
| |
Collapse
|
33
|
Benkhadra K, Alahdab F, Tamhane S, Wang Z, Prokop LJ, Hirsch IB, Raccah D, Riveline JP, Kordonouri O, Murad MH. Real-time continuous glucose monitoring in type 1 diabetes: a systematic review and individual patient data meta-analysis. Clin Endocrinol (Oxf) 2017; 86:354-360. [PMID: 27978595 DOI: 10.1111/cen.13290] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 09/28/2016] [Accepted: 12/04/2016] [Indexed: 01/22/2023]
Abstract
BACKGROUND Real-time continuous glucose monitoring (RTCGM) may help in the management of individuals with type 1 diabetes mellitus (T1DM); however, the evidence supporting its use is unclear. The available meta-analyses on this topic use aggregate data which weaken inference. OBJECTIVE Individual patient data were obtained from randomized controlled trials (RCTs) to conduct a meta-analysis and synthesize evidence about the effect of RTCGM on glycosylated haemoglobin (HbA1c), hypoglycaemic events and time spent in hypoglycaemia in T1DM. METHODS We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials and Database of Systematic Reviews, and Scopus through January 2015. We included RCTs that enrolled individuals with T1DM and compared RTCGM vs control group. A two-step regression model was used to pool individual patient data. RESULTS We included 11 RCTs at moderate risk of bias. Meta-analysis suggests that the use of RTCGM is associated with a statistically significant but modest reduction in HbA1c (-0·276; 95% confidence interval -0·465 to -0·087). The improvements in HbA1c were primarily seen in individuals over age 15 years. We were unable to identify a statistically significant difference in time spent in hypoglycaemia or the number of hypoglycaemic episodes although these analyses were imprecise and warrant lower confidence. There was no difference between males and females. CONCLUSION RTCGM in T1DM is associated with a reduction in HbA1c primarily in individuals over 15 years of age. We were unable to identify a statistically significant difference in the time spent in hypoglycaemia or the incidence of hypoglycaemic episodes.
Collapse
Affiliation(s)
- Khalid Benkhadra
- Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN, USA
- Division of Preventive Medicine, Mayo Clinic, Rochester, MN, USA
| | - Fares Alahdab
- Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN, USA
- Division of Preventive Medicine, Mayo Clinic, Rochester, MN, USA
| | - Shrikant Tamhane
- Division of Endocrinology, Diabetes and Nutrition, Rochester, MN, USA
| | - Zhen Wang
- Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN, USA
| | - Larry J Prokop
- Library Public Services, Mayo Clinic, Rochester, MN, USA
| | - Irl B Hirsch
- University of Washington Med Ctr-Roosevelt, Seattle, WA, USA
| | - Denis Raccah
- University Hospital Sainte Marguerite, Marseille, France
| | | | | | - Mohammad Hassan Murad
- Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN, USA
- Division of Preventive Medicine, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
34
|
Bronstone A, Graham C. The Potential Cost Implications of Averting Severe Hypoglycemic Events Requiring Hospitalization in High-Risk Adults With Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring. J Diabetes Sci Technol 2016; 10:905-13. [PMID: 26880392 PMCID: PMC4928227 DOI: 10.1177/1932296816633233] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND Severe hypoglycemia remains a major barrier to optimal diabetes management and places a high burden on the US health care system due to the high costs of hypoglycemia-related emergency visits and hospitalizations. Patients with type 1 diabetes (T1DM) who have hypoglycemia unawareness are at a particularly high risk for severe hypoglycemia, the incidence of which may be reduced by the use of real-time continuous glucose monitoring (RT-CGM). METHODS We performed a cost calculation using values of key parameters derived from various published sources to examine the potential cost implications of standalone RT-CGM as a tool for reducing rates of severe hypoglycemia requiring hospitalization in adult patients with T1DM who have hypoglycemia unawareness. RESULTS In a hypothetical commercial health plan with 10 million members aged 18-64 years, 9.3% (930 000) are expected to have diagnosed diabetes, with approximately 5% (46 500) having T1DM, of whom approximately 20% (9300) have hypoglycemia unawareness. RT-CGM was estimated to reduce the cost of annual hypoglycemia-related hospitalizations in this select population by $54 369 000, yielding an estimated net cost savings of $8 799 000 to $12 519 000 and a savings of $946 to $1346 per patient. CONCLUSION This article presents a cost calculation based on available data from multiple sources showing that RT-CGM has the potential to reduce short-term health care costs by averting severe hypoglycemic events requiring hospitalization in a select high-risk population. Prospective, randomized studies that are adequately powered and specifically enroll patients at high risk for severe hypoglycemia are needed to confirm that RT-CGM significantly reduces the incidence of these costly events.
Collapse
|
35
|
Dovč K, Bratina N, Battelino T. A new horizon for glucose monitoring. Horm Res Paediatr 2016; 83:149-56. [PMID: 25660230 DOI: 10.1159/000368924] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Accepted: 10/06/2014] [Indexed: 11/19/2022] Open
Abstract
Regular self-monitoring of blood glucose is crucial for proper insulin dosing and gives a reliable foundation for reasonable glycaemic control. According to recent data, recommended values for glycated haemoglobin A1c as set by the professional associations remain out of the reach for a large proportion of the paediatric population. In the last decades, the treatment of type 1 diabetes has changed significantly as new devices gain a role in routine clinical care. Real-time glucose levels can be monitored with continuous glucose monitoring (CGM), which provides a broad spectrum of information on glucose trends on a moment-to-moment basis. This information can be useful for patients' decision making and clinicians' understanding of patients' conduct. However, several barriers, including the current price, impede a broader use of CGM in most regions of the world. This review summarizes data from randomized, controlled trials that included a paediatric population, and it provides some evidence-based visions for the possible broader utilization of CGM, also for incorporation into insulin delivery devices that enable a closed-loop insulin delivery.
Collapse
Affiliation(s)
- Klemen Dovč
- Department of Endocrinology, Diabetes and Metabolism, UMC, University Children's Hospital, Ljubljana, Slovenia
| | | | | |
Collapse
|
36
|
Gómez AM, Umpierrez GE, Muñoz OM, Herrera F, Rubio C, Aschner P, Buendia R. Continuous Glucose Monitoring Versus Capillary Point-of-Care Testing for Inpatient Glycemic Control in Type 2 Diabetes Patients Hospitalized in the General Ward and Treated With a Basal Bolus Insulin Regimen. J Diabetes Sci Technol 2015; 10:325-9. [PMID: 26330394 PMCID: PMC4773955 DOI: 10.1177/1932296815602905] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) may improve the management of patients with type 2 diabetes hospitalized in the general ward by facilitating the detection of hyper- and hypoglycemic episodes. However, the lack of data on the accuracy and safety of CGM have limited its application. METHODS A prospective pilot study was conducted including 38 patients hospitalized in the general ward with a known diagnosis of type 2 diabetes mellitus (DM) and hyperglycemic individuals without a history of DM with a blood sugar of 140-400 mg on admission treated with a basal bolus insulin regimen. Inpatient glycemic control and the incidence of hypoglycemic episodes were compared between detection by CGM of interstitial fluid for up to 6 days and point-of-care (POC) capillary blood glucose monitoring performed pre- and postprandially, before bedtime and at 3 am. RESULTS No differences in average daily glucose levels were observed between CGM and POC (176.2 ± 33.9 vs 176.6 ± 33.7 mg/dl, P = .828). However, CGM detected a higher number of hypoglycemic episodes than POC (55 vs 12, P < .01). Glucose measurements were clinically valid, with 91.9% of patients falling within the Clarke error grid A and B zones. CONCLUSIONS Our preliminary results indicate that the use of CGM in type 2 patients hospitalized in the general ward provides accurate estimation of blood sugar levels and is more effective than POC for the detection of hypoglycemic episodes and asymptomatic hypoglycemia.
Collapse
Affiliation(s)
- Ana M Gómez
- Pontificia Universidad Javeriana, Bogotá, Colombia Hospital Universitario San Ignacio, Bogotá, Colombia
| | - Guillermo E Umpierrez
- Department of Medicine, Emory University, Atlanta, GA, USA Division of Endocrinology, Metabolism and Lipids, Emory University, Atlanta, GA, USA
| | - Oscar M Muñoz
- Pontificia Universidad Javeriana, Bogotá, Colombia Hospital Universitario San Ignacio, Bogotá, Colombia Department of Internal Medicine, Pontificia Universidad Javeriana, Hospital Universitario San Ignacio, Bogotá, Colombia
| | - Felipe Herrera
- Pontificia Universidad Javeriana, Bogotá, Colombia Hospital Universitario San Ignacio, Bogotá, Colombia
| | - Claudia Rubio
- Hospital Universitario San Ignacio, Bogotá, Colombia Clínica La Colina, Bogotá, Colombia
| | - Pablo Aschner
- Pontificia Universidad Javeriana, Bogotá, Colombia Hospital Universitario San Ignacio, Bogotá, Colombia Endocrinology Unit, Department of Internal Medicine, Pontificia Universidad Javeriana, Hospital Universitario San Ignacio, Bogotá, Colombia
| | - Richard Buendia
- Endocrinology Unit, Department of Internal Medicine, Pontificia Universidad Javeriana, Hospital Universitario San Ignacio, Bogotá, Colombia
| |
Collapse
|
37
|
Heinemann L, Deiss D, Hermanns N, Graham C, Kaltheuner M, Liebl A, Price D. HypoDE: Research Design and Methods of a Randomized Controlled Study Evaluating the Impact of Real-Time CGM Usage on the Frequency of CGM Glucose Values <55 mg/dl in Patients With Type 1 Diabetes and Problematic Hypoglycemia Treated With Multiple Daily Injections. J Diabetes Sci Technol 2015; 9:651-62. [PMID: 25759183 PMCID: PMC4604551 DOI: 10.1177/1932296815575999] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Systems for continuous glucose monitoring (CGM) have been available for a number of years, and numerous clinical studies have been performed with them. Interestingly, in many of these studies patients with an increased risk of hypoglycemic events were excluded. In addition, in most studies subjects were using a pump for insulin delivery. Therefore our knowledge about the benefit of CGM in patients employing multiple daily injections (MDI) of insulin is limited, especially when it comes to a reduction in the risk of low glucose events in high-risk individuals. We are planning to run a 26-week randomized controlled study in Germany (HypoDE, Hypoglycemia in Deutschland) that is focused on evaluating if such a reduction can be observed in patients on MDI with an increased risk of low glucose events. In all, 160 patients will participate in the study, randomized into the intervention group and control group. Ideally one would study if the frequency of severe hypoglycemic events is different between both groups. However, this would require such a large sample size and study duration, so for pragmatic reasons we will use low glucose levels <55 mg/dl (measured by CGM) for at least 20 minutes as a risk marker for severe hypoglycemic events. The results from the HypoDE study shall help determine the advantage of using CGM in subjects with type 1 diabetes with an increased risk of low glucose events treated with MDI.
Collapse
Affiliation(s)
| | | | - Norbert Hermanns
- Forschungsinstitut Diabetes Akademie Bad Mergentheim (FIDAM), Bad Mergentheim, Germany
| | | | | | | | - David Price
- Forschungsinstitut Diabetes Akademie Bad Mergentheim (FIDAM), Bad Mergentheim, Germany
| |
Collapse
|
38
|
Vigersky RA. The benefits, limitations, and cost-effectiveness of advanced technologies in the management of patients with diabetes mellitus. J Diabetes Sci Technol 2015; 9:320-30. [PMID: 25555391 PMCID: PMC4604582 DOI: 10.1177/1932296814565661] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Hypoglycemia mitigation is critical for appropriately managing patients with diabetes. Advanced technologies are becoming more prevalent in diabetes management, but their benefits have been primarily judged on the basis of hemoglobin A1c. A critical appraisal of the effectiveness and limitations of advanced technologies in reducing both A1c and hypoglycemia rates has not been previously performed. The cost of hypoglycemia was estimated using literature rates of hypoglycemia events resulting in hospitalizations. A literature search was conducted on the effect on A1c and hypoglycemia of advanced technologies. The cost-effectiveness of continuous subcutaneous insulin infusion (CSII) and real-time continuous glucose monitors (RT-CGM) was reviewed. Severe hypoglycemia in insulin-using patients with diabetes costs $4.9-$12.7 billion. CSII reduces A1c in some but not all studies. CSII improves hypoglycemia in patients with high baseline rates. Bolus calculators improve A1c and improve the fear of hypoglycemia but not hypoglycemia rates. RT-CGM alone and when combined with CSII improve A1c with a neutral effect on hypoglycemia rates. Low-glucose threshold suspend systems reduce hypoglycemia with a neutral effect on A1c, and low-glucose predictive suspend systems reduce hypoglycemia with a small increase in plasma glucose levels. In short-term studies, artificial pancreas systems reduce both hypoglycemia rates and plasma glucose levels. CSII and RT-CGM are cost-effective technologies, but their wide adoption is limited by cost, psychosocial, and educational factors. Most currently available technologies improve A1c with a neutral or improved rate of hypoglycemia. Advanced technologies appear to be cost-effective in diabetes management, especially when including the underlying cost of hypoglycemia.
Collapse
Affiliation(s)
- Robert A. Vigersky
- Walter Reed National Military Medical Center, Bethesda, MD, USA
- Robert A. Vigersky, MD, Endocrinology and Diabetes Service, Department of Medicine, Walter Reed National Military Medical Center, 8901 Wisconsin Ave, Bethesda, MD 20889, USA.
| |
Collapse
|
39
|
Vrančić C, Kröger N, Gretz N, Neudecker S, Pucci A, Petrich W. A Quantitative Look Inside the Body: Minimally Invasive Infrared Analysis in Vivo. Anal Chem 2014; 86:10511-4. [DOI: 10.1021/ac5028808] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Christian Vrančić
- Kirchhoff-Institute
for Physics, Heidelberg University, INF 227, 69120 Heidelberg, Germany
| | - Niels Kröger
- Kirchhoff-Institute
for Physics, Heidelberg University, INF 227, 69120 Heidelberg, Germany
| | - Norbert Gretz
- Medical
Research Center, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68176 Mannheim, Germany
| | - Sabine Neudecker
- Medical
Research Center, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68176 Mannheim, Germany
| | - Annemarie Pucci
- Kirchhoff-Institute
for Physics, Heidelberg University, INF 227, 69120 Heidelberg, Germany
| | - Wolfgang Petrich
- Kirchhoff-Institute
for Physics, Heidelberg University, INF 227, 69120 Heidelberg, Germany
| |
Collapse
|
40
|
Abstract
Inpatient hyperglycemia, in patients with and without a history of diabetes, is associated with increased risk of complications, mortality, and longer hospital stay in medicine and surgical patients. Bedside capillary point of care testing is widely recommended as the preferred method for glucose monitoring and for guiding glycemic management of individual patients; however, the accuracy of most handheld glucose meters is far from optimal. Recent studies in the hospital setting have reported that the use of continuous glucose monitoring (CGM) can provide real-time information about glucose concentration, direction, and rate of change over a period of several days. Because it provides glucose values every 5-10 minutes 24 hours a day, CGM may have an advantage over point of care testing with respect to reducing the incidence of severe hypoglycemia in acute care. Real-time CGM technology may facilitate glycemic control and to reduce hypoglycemia in insulin-treated patients. Recent guidelines, however, have recommended deferring the use of CGM in the adult hospital setting until further data on accuracy and safety become available. In this study, we review the advantages and disadvantages of the use of real-time CGM in the management of dysglycemia in the hospital setting.
Collapse
Affiliation(s)
- Ana Maria Gomez
- Department of Medicine, Universidad Javeriana, Bogota, Colombia
| | | |
Collapse
|
41
|
Patton SR, DeLurgio SA, Fridlington A, Cohoon C, Turpin AL, Clements MA. Frequency of mealtime insulin bolus predicts glycated hemoglobin in youths with type 1 diabetes. Diabetes Technol Ther 2014; 16:519-23. [PMID: 24773597 PMCID: PMC4172563 DOI: 10.1089/dia.2013.0356] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
BACKGROUND Within pediatric diabetes management, two electronic measures of adherence exist: frequency of daily blood glucose monitoring (BGM) and the BOLUS score, a measure of frequency of mealtime insulin bolusing. Past research has demonstrated that the BOLUS score is superior to daily BGM in predicting youths' glycated hemoglobin (HbA1c) in a cross-sectional study. We present data comparing the two adherence measures in predicting HbA1c using a prospective, longitudinal design. SUBJECTS AND METHODS Blood glucose meter data and insulin pump records were collected from a clinical database of 175 youths with type 1 diabetes (mean age, 11.7 ± 3.6 years at baseline). Youths' HbA1c levels occurring at the download time and at 3, 6, 9, and 12 months post-downloads were also collected. We calculated youths' mean BGM and BOLUS score using a standardized protocol. RESULTS Intraclass correlations (ICCs) revealed significant absolute equivalence between youths' predicted HbA1c values using BOLUS and BGM scores and future actual HbA1c values up to 12 months post-download. However, the ICCs of BOLUS scores with future HbA1c values were consistently higher than those of the BGM scores. Also, the predictions of the BOLUS scores were significantly more accurate (P ≤ 0.002) than those of the BGM scores based on the root mean squared error of predictions. CONCLUSIONS In a prospective, longitudinal design, youths' BOLUS scores were superior to youths' daily BGM in predicting future values of HbA1c. Calculating a BOLUS score versus BGM can help researchers and clinicians achieve a better prediction of youths' HbA1c.
Collapse
Affiliation(s)
- Susana R. Patton
- Department of Pediatrics, University of Kansas Medical Center, Kansas City, Kansas
| | - Stephen A. DeLurgio
- Health Outcomes Research Department, Children's Mercy Hospital, Kansas City, Missouri
| | - Amanda Fridlington
- Division of Endocrinology, Children's Mercy Hospital, Kansas City, Missouri
| | - Cyndy Cohoon
- Division of Endocrinology, Children's Mercy Hospital, Kansas City, Missouri
| | - Angela L. Turpin
- Division of Endocrinology, Children's Mercy Hospital, Kansas City, Missouri
| | - Mark A. Clements
- Division of Endocrinology, Children's Mercy Hospital, Kansas City, Missouri
| |
Collapse
|
42
|
Bajwa SJS, Sehgal V, Kalra S, Baruah MP. Management of diabetes mellitus type-2 in the geriatric population: Current perspectives. J Pharm Bioallied Sci 2014; 6:151-7. [PMID: 25035634 PMCID: PMC4097928 DOI: 10.4103/0975-7406.130956] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Revised: 06/06/2013] [Accepted: 09/29/2013] [Indexed: 01/04/2023] Open
Abstract
The prevalence of diabetes mellitus (DM) has increased exponentially throughout the world and there is rapid increase in elderly diabetics. DM is associated with increased mortality and considerable morbidity including stroke, heart disease, and diminished quality of life in the elderly. However, the unique features of geriatric diabetes have not been given due a prominence in medical literature. Hypoglycemia remains the biggest complicating factor and needs to be avoided in the elderly. Most people in the geriatric age group have some degree of renal insufficiency and medications need to be adjusted wisely with changing renal profile. Because safer and more effective pharmacological therapy is available, an individual approach to DM in the elderly is essential.
Collapse
Affiliation(s)
- Sukhminder Jit Singh Bajwa
- Department of Anaesthesiology and Intensive Care Medicine, Gian Sagar Medical College and Hospital, Patiala, Punjab, India
| | - Vishal Sehgal
- Department of Internal Medicine, The Common Wealth Medical College, Scranton, PA 18510, USA
| | - Sanjay Kalra
- Department of Endocrinology, Bharti Hospital and B.R.I.D.E., Karnal, Haryana, India
| | | |
Collapse
|
43
|
Abstract
Currently used error grids for assessing clinical accuracy of blood glucose monitors are based on out-of-date medical practices. Error grids have not been widely embraced by regulatory agencies for clearance of monitors, but this type of tool could be useful for surveillance of the performance of cleared products. Diabetes Technology Society together with representatives from the Food and Drug Administration, the American Diabetes Association, the Endocrine Society, and the Association for the Advancement of Medical Instrumentation, and representatives of academia, industry, and government, have developed a new error grid, called the surveillance error grid (SEG) as a tool to assess the degree of clinical risk from inaccurate blood glucose (BG) monitors. A total of 206 diabetes clinicians were surveyed about the clinical risk of errors of measured BG levels by a monitor. The impact of such errors on 4 patient scenarios was surveyed. Each monitor/reference data pair was scored and color-coded on a graph per its average risk rating. Using modeled data representative of the accuracy of contemporary meters, the relationships between clinical risk and monitor error were calculated for the Clarke error grid (CEG), Parkes error grid (PEG), and SEG. SEG action boundaries were consistent across scenarios, regardless of whether the patient was type 1 or type 2 or using insulin or not. No significant differences were noted between responses of adult/pediatric or 4 types of clinicians. Although small specific differences in risk boundaries between US and non-US clinicians were noted, the panel felt they did not justify separate grids for these 2 types of clinicians. The data points of the SEG were classified in 15 zones according to their assigned level of risk, which allowed for comparisons with the classic CEG and PEG. Modeled glucose monitor data with realistic self-monitoring of blood glucose errors derived from meter testing experiments plotted on the SEG when compared to the data plotted on the CEG and PEG produced risk estimates that were more granular and reflective of a continuously increasing risk scale. The SEG is a modern metric for clinical risk assessments of BG monitor errors that assigns a unique risk score to each monitor data point when compared to a reference value. The SEG allows the clinical accuracy of a BG monitor to be portrayed in many ways, including as the percentages of data points falling into custom-defined risk zones. For modeled data the SEG, compared with the CEG and PEG, allows greater precision for quantifying risk, especially when the risks are low. This tool will be useful to allow regulators and manufacturers to monitor and evaluate glucose monitor performance in their surveillance programs.
Collapse
Affiliation(s)
| | - Courtney Lias
- US Food and Drug Administration, Silver Spring, MD, USA
| | - Robert Vigersky
- Walter Reed National Military Medical Center, Bethesda, MD, USA
| | | | | | | | | | | |
Collapse
|
44
|
Early assessment of glucose abnormalities during continuous glucose monitoring associated with lung function impairment in cystic fibrosis patients. J Cyst Fibros 2014; 13:478-84. [DOI: 10.1016/j.jcf.2013.11.005] [Citation(s) in RCA: 70] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Revised: 10/13/2013] [Accepted: 11/18/2013] [Indexed: 01/07/2023]
|
45
|
Position statement: hypoglycemia management in patients with diabetes mellitus. Diabetes Mellitus Working Group of the Spanish Society of Endocrinology and Nutrition. ACTA ACUST UNITED AC 2013; 60:517.e1-517.e18. [PMID: 23916172 DOI: 10.1016/j.endonu.2013.04.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Accepted: 04/16/2013] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To provide practical recommendations for evaluation and management of hypoglycemia in patients with diabetes mellitus. PARTICIPANTS Members of the Diabetes Mellitus Working Group of the Spanish Society of Endocrinology and Nutrition. METHODS Recommendations were formulated according to the Grading of Recommendations, Assessment, Development, and Evaluation system to describe both the strength of recommendations and the quality of evidence. A systematic search was made in MEDLINE (PubMed). Papers in English and Spanish with publication date before 15 February 2013 were included. For recommendations about drugs only those approved by the European Medicines Agency were included. After formulation of recommendations, they were discussed by the Working Group. CONCLUSIONS The document provides evidence-based practical recommendations for evaluation and management of hypoglycemia in patients with diabetes mellitus.
Collapse
|