1
|
Apostolou A, Leichert HJ, König AM, Owczarek AD, Mahnken AH. Efficiency in radiation protection of a novel exoskeleton-based interventional radiology apron and correlation with conventional aprons. Eur J Radiol 2025; 184:111946. [PMID: 39946813 DOI: 10.1016/j.ejrad.2025.111946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Revised: 01/10/2025] [Accepted: 01/21/2025] [Indexed: 03/05/2025]
Abstract
PURPOSE In interventional radiology (IR), safeguarding against ionizing radiation is imperative. This study evaluates the comparison of a lead-free exoskeleton-mounted radiation protection apron with an integrated head visor with conventional radiation protection aprons of varied materials. The goal is to contribute insights into optimizing safety for healthcare professionals and patients during IR procedures. METHODS The phantom study incorporates a variety of radiation protection aprons: an exoskeleton-mounted lead-free apron with an integrated head visor, a conventional lead apron, a lead- free and a lead-composite apron. The examiner assumed three common working positions (30° left, 0° center, 30° right) during a simulated intervention. A volume tomography cone beam protocol (CBCT) ensured a consistent spectrum of radiation energy. Real-time dosimeters were placed at the eyes, the left axilla, and the pelvis. RESULTS The exoskeleton-mounted apron with the integrated head visor demonstrated an average dose reduction of 93.4 % (p < 0.001), outperforming other aprons with shielding capacities only up to 66 % (p < 0.001). The other aprons were deliberately chosen without eye shielding. In the pelvic region, the exoskeleton-mounted apron achieved a 99 % (p < 0.001) dose reduction, with the lead-free apron providing 96 % (p < 0.001) shielding efficacy, and the conventional lead and lead-composite aprons achieving 94 % (p < 0.001) and 90.3 % (p < 0.001), respectively. However, the exoskeleton-mounted apron exhibited a lower dose reduction of 81.3 % (p < 0.001) in the left axilla compared to conventional aprons. CONCLUSIONS The evaluated exoskeleton system demonstrated excellent eye protection through its circumferential head visor and notable reduction in the pelvic dose. However, despite these advantages, the exoskeleton did exhibit a particular deficit in the left axilla in our experimental setup. This research emphasizes the potential of innovative radiation protection solutions while highlighting specific areas that require further improvement.
Collapse
Affiliation(s)
- A Apostolou
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Germany; Philipps-University of Marburg, Department of diagnostic and interventional Radiology, Marburg, Germany.
| | - H J Leichert
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Germany; Philipps-University of Marburg, Department of diagnostic and interventional Radiology, Marburg, Germany
| | - A M König
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Germany; Philipps-University of Marburg, Department of diagnostic and interventional Radiology, Marburg, Germany
| | - A D Owczarek
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Germany; Philipps-University of Marburg, Department of diagnostic and interventional Radiology, Marburg, Germany
| | - A H Mahnken
- Department of Diagnostic and Interventional Radiology, University Hospital Marburg, Germany; Philipps-University of Marburg, Department of diagnostic and interventional Radiology, Marburg, Germany
| |
Collapse
|
2
|
Awikunprasert P, Rueansri J, Suangamiam K, Koedsawat C, Tamon S, Kittiva N, Dachviriyakij T. Radiation dose at the eye lens of patients undergoing radiation therapy for head and neck cancer. Radiol Phys Technol 2025:10.1007/s12194-025-00886-2. [PMID: 39923219 DOI: 10.1007/s12194-025-00886-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2024] [Revised: 01/19/2025] [Accepted: 01/27/2025] [Indexed: 02/10/2025]
Abstract
Linear accelerator irradiation, the most common treatment for head and neck cancer, requires accurate prediction of lens radiation doses to ensure patient safety. The eye lens, being highly radiosensitive and vulnerable to scattered radiation, is at increased risk of developing cataracts. This study compared radiation doses calculated by the treatment planning system (TPS) with those measured in vivo using optically stimulated luminescence (OSL) dosimeters placed on the eyes of 18 patients undergoing radiotherapy for various head and neck cancers. Bland-Altman analysis was used to assess the agreement between the two methods. The results showed that TPS-calculated doses were significantly higher than OSL-measured doses, with TPS values averaging twice as high. However, in three cases, the measured OSL doses exceeded the TPS predictions. The Bland-Altman plot revealed poor agreement between the two methods. The mean doses to the left and right eye lenses were 182 cGy and 170 cGy, respectively, with the highest recorded doses being 492 cGy for the left eye and 513 cGy for the right eye. Patients with nasopharyngeal cancer received the highest doses, and four patients had doses in the 3-5 Gy range, increasing their risk of cataracts. These findings emphasize the importance of validating TPS accuracy in clinical practice to ensure optimal patient care. Further research is necessary to explore the discrepancies between dose measurements and enhance TPS precision, improving clinical outcomes and patient safety in radiation therapy.
Collapse
Affiliation(s)
- Panatsada Awikunprasert
- Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
| | | | - Kittipong Suangamiam
- Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Chaknarin Koedsawat
- Department of Radiological Technology, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | - Surasak Tamon
- Division of Radiotherapy, Lampang Cancer Hospital, Lampang, Thailand
| | - Nattakarn Kittiva
- Division of Radiotherapy, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand
| | | |
Collapse
|
3
|
Kuriyama T, Moritake T, Hitomi G, Nakagami K, Morota K, Matsuzaki S, Sakamoto H, Matsumoto K, Kato M, Kitamura H. Influence of Hospital Bed Count on the Positioning of Cardiovascular Interventional Radiology (IR) Nurses: Online Questionnaire Survey of Japanese IR-Specialized Radiological Technologists. NURSING REPORTS 2025; 15:11. [PMID: 39852633 PMCID: PMC11767440 DOI: 10.3390/nursrep15010011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2024] [Revised: 12/23/2024] [Accepted: 01/02/2025] [Indexed: 01/26/2025] Open
Abstract
BACKGROUND/OBJECTIVES Interventional radiology (IR) utilizing X-rays can lead to occupational radiation exposure, posing health risks for medical personnel in the field. We previously conducted a survey on the occupational radiation exposure of IR nurses in three designated emergency hospitals in Japan. Our findings indicated that a hospital with 214 beds showed a higher lens-equivalent dose than hospitals with 678 and 1182 beds because the distance between the X-ray irradiation field and the IR nurse's position of the hospital with 214 beds was shorter than those of 678 and 1182 beds. Based on these observations, we hypothesized that the number of hospital beds affects the distance between the X-ray irradiation field and the IR nurse's position. METHODS To verify this hypothesis, we conducted a more extensive online questionnaire survey, focusing exclusively on hospitals that perform cardiovascular IR. RESULTS We analyzed data from 78 facilities. The results of this study confirmed our earlier findings, showing that both the number of physicians performing IR procedures and the distance from the X-ray irradiation field to the IR nurse's position are influenced by the number of hospital beds. Additionally, factors such as the type of hospital, emergency medical system, annual number of IR sessions, location of medical equipment, and the positioning of IR nurses appear to be associated with the number of hospital beds. CONCLUSIONS Understanding these relationships could enable the development of individualized and prioritized radiation exposure reduction measures for IR nurses in high-risk settings, provided that comprehensive occupational radiation risk assessments for cardiovascular IR consider the number of hospital beds and related factors. This study was not registered.
Collapse
Affiliation(s)
- Tomoko Kuriyama
- Department of Occupational and Community Health Nursing, School of Health Sciences, University of Occupational and Environmental Health, Japan, Kitakyushu 807-8555, Japan;
| | - Takashi Moritake
- Department of Radiation Regulatory Science Research, Institute for Radiological Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan;
| | - Go Hitomi
- Department of Radiological Technology, Kawasaki Medical School Hospital, Kurashiki 701-0192, Japan;
| | - Koichi Nakagami
- Department of Radiology, Hospital of the University of the Occupational and Environmental Health, Japan, Kitakyushu 807-8556, Japan;
| | - Koichi Morota
- Department of Radiology, Shinkomonji Hospital, Kitakyushu 800-0057, Japan;
| | - Satoru Matsuzaki
- Department of Radiation Regulatory Science Research, Institute for Radiological Science, National Institutes for Quantum Science and Technology, Chiba 263-8555, Japan;
| | - Hajime Sakamoto
- Department of Radiological Technology, Faculty of Health Science, Juntendo University, Tokyo 113-8421, Japan;
| | - Kazuma Matsumoto
- Department of Radiological Technology, Hyogo Medical University Hospital, Nishinomiya 663-8501, Japan;
| | - Mamoru Kato
- Department of Radiology and Nuclear Medicine, Akita Cerebrospinal and Cardiovascular Center, Akita 010-0874, Japan;
| | - Hiroko Kitamura
- Occupational Health Training Center, University of Occupational and Environmental Health, Japan, Kitakyushu 807-8555, Japan;
| |
Collapse
|
4
|
Liu Y, Gao Y, Jin L, Li Q, Wang X, Wu Y, Zhou J, Liu W, Wang L, Dong Y, Zheng Y, Chen L, Li J, Su S, Tang J, Wang Y, Huang W, Cheng C, Li C, An N, Tan J, Chen H, Guo H, Wang Y, Zhou Q, Han F, Liu H, Zhu Y, Lu R. Safety and efficacy of intralesional rituximab injection versus involved site radiation therapy in primary ocular adnexal MALT lymphoma: study protocol for a multicentre randomised controlled trial. BMJ Open 2024; 14:e084904. [PMID: 39608989 PMCID: PMC11603821 DOI: 10.1136/bmjopen-2024-084904] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 11/11/2024] [Indexed: 11/30/2024] Open
Abstract
INTRODUCTION Involved site radiation therapy (ISRT) is a widely used treatment for primary ocular adnexal mucosa-associated lymphoid tissue (MALT) lymphoma with control rates over 85%; however, its complications could reach 30%-50%. Intralesional rituximab injection has shown promising results with remission rates between 65% and 100% and minimal complications. This study aimed to conduct a multicentre randomised controlled clinical trial to compare the safety and efficacy of intralesional rituximab injection versus ISRT on primary ocular adnexal MALT lymphoma. METHODS AND ANALYSIS This is a multicentre randomised controlled trial and will be conducted at eight ophthalmic departments and institutes in China. 108 patients with primary ocular adnexal MALT lymphoma will be enrolled and randomised to undergo intralesional rituximab injection or ISRT. Comprehensive examinations will be performed before and after the treatment. The primary outcome is the cumulative occurrence rate of complications of grade ≥2 within 5 years after treatment commencement. The main secondary outcome is overall response rate, and progression-free survival, time to next treatment and overall survival will also be compared between the groups. ETHICS AND DISSEMINATION Ethical approval has been obtained from the Ethics Committee of the Zhongshan Ophthalmic Center (ID: 2023KYPJ125-3; V.20240818) and the '5010 Plan' evaluation committee at Sun Yat-sen University, Guangzhou, China, and all subcentres. All the participants will be required to provide written informed consent. The results will be disseminated through scientific meetings and published in peer-reviewed journals. TRIAL REGISTRATION NUMBER NCT06190301.
Collapse
Affiliation(s)
- Yaoming Liu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Yang Gao
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Ling Jin
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Qian Li
- People's Hospital of Ningxia Hui Autonomous Region, Yinchuan, Ningxia, China
| | - Xiaohui Wang
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, China
| | - Yujie Wu
- Xi'an People's Hospital Shaanxi Eye Hospital, Xi'an, Shaanxi, China
| | - Jichao Zhou
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Wei Liu
- Department of Ophthalmology, Huazhong University of Science and Technology, Wuhan, China
| | - Lili Wang
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Yuying Dong
- Department of Ophthalmology, Jinan University First Affiliated Hospital, Guangzhou, Guangdong, China
| | - Yajing Zheng
- Hainan Eye Hospital and Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China
| | - Lu Chen
- Eye Center of Xiangya Hospital, Central South University, Changsha, China
| | - Jinmiao Li
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Shicai Su
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Junjie Tang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Yinghao Wang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Weifeng Huang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Chao Cheng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Cheng Li
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| | - Ningyu An
- People's Hospital of Ningxia Hui Autonomous Region, Yinchuan, Ningxia, China
| | - Jia Tan
- Eye Center of Xiangya Hospital, Central South University, Changsha, China
| | - Hong Chen
- Department of Ophthalmology, Huazhong University of Science and Technology, Wuhan, China
| | - Huiyu Guo
- Hainan Eye Hospital and Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China
| | - Yi Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Qing Zhou
- Department of Ophthalmology, Jinan University First Affiliated Hospital, Guangzhou, Guangdong, China
| | - Fei Han
- Department of Radiation Oncology, State Key Laboratory of Oncology in South China, Sun Yat-sen University Cancer Center, Guangzhou, Guangdong, China
| | - Honglei Liu
- Xi'an People's Hospital Shaanxi Eye Hospital, Xi'an, Shaanxi, China
| | - Yu Zhu
- Department of Ophthalmology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan, China
| | - Rong Lu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-Sen University, Guangzhou, Guangdong, China
| |
Collapse
|
5
|
Ibáñez B, Melero A, Montoro A, San Onofre N, Soriano JM. Molecular Insights into Radiation Effects and Protective Mechanisms: A Focus on Cellular Damage and Radioprotectors. Curr Issues Mol Biol 2024; 46:12718-12732. [PMID: 39590349 PMCID: PMC11592695 DOI: 10.3390/cimb46110755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2024] [Revised: 11/05/2024] [Accepted: 11/08/2024] [Indexed: 11/28/2024] Open
Abstract
Ionizing radiation has been a critical tool in various fields, such as medicine, agriculture, and energy production, since its discovery in 1895. While its applications-particularly in cancer treatment and diagnostics-offer significant benefits, ionizing radiation also poses risks due to its potential to cause molecular and cellular damage. This damage can occur through the direct ionization of biological macromolecules, such as deoxyribonucleic acid (DNA), or indirectly through the radiolysis of water, which generates reactive oxygen species (ROS) that further damage cellular components. Radioprotectors, compounds that protect against radiation-induced damage, have been extensively researched since World War II. These agents work by enhancing DNA repair, scavenging free radicals, and boosting antioxidant defenses, thereby protecting healthy tissues. Furthermore, some radioprotective agents also stimulate DNA repair mechanisms even after radiation exposure, aiding in recovery from radiation-induced damage. This article explores the molecular mechanisms of radiation-induced damage, focusing on both direct and indirect effects on DNA, and discusses the role of radioprotectors, their mechanisms of action, and recent advancements in the field. The findings underscore the importance of developing effective radioprotective strategies, particularly in medical and industrial settings, where radiation exposure is prevalent.
Collapse
Affiliation(s)
- Blanca Ibáñez
- Food & Health Laboratory, Institute of Materials Science, University of Valencia, 46980 Paterna, Spain; (B.I.); (N.S.O.)
| | - Ana Melero
- Department of Pharmacy and Pharmaceutical Technology and Parasitology, Faculty of Pharmacy, University of Valencia, 46100 Burjassot, Spain;
| | - Alegría Montoro
- Service of Radiological Protection, Clinical Area of Medical Image, University and Polytechnic La Fe Hospital, 46026 Valencia, Spain;
- Biomedical Imaging Research Group GIBI230, Health Research Institute (IISLaFe), University and Polytechnic La Fe Hospital, 46026 Valencia, Spain
| | - Nadia San Onofre
- Food & Health Laboratory, Institute of Materials Science, University of Valencia, 46980 Paterna, Spain; (B.I.); (N.S.O.)
- Department of Community Nursing, Preventive Medicine and Public Health and History of Science, University of Alicante, 03690 Alicante, Spain
- FoodLab Research Group, Faculty of Health Sciences, Universitat Oberta de Catalunya, Rambla del Poblenou 156, 08018 Barcelona, Spain
| | - Jose M. Soriano
- Food & Health Laboratory, Institute of Materials Science, University of Valencia, 46980 Paterna, Spain; (B.I.); (N.S.O.)
- Joint Research Unit on Endocrinology, Nutrition and Clinical Dietetics, Health Research Institute La Fe, University of Valencia, 46026 Valencia, Spain
| |
Collapse
|
6
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Comparison of the equivalent doses of the eye lenses, thyroid, and mammary gland among three pediatric and one adult anthropomorphic phantom during the chest CT examinations using a 40 mm volume helical scan. RADIATION PROTECTION DOSIMETRY 2024; 200:1391-1397. [PMID: 38997113 DOI: 10.1093/rpd/ncae165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 06/04/2024] [Accepted: 07/02/2024] [Indexed: 07/14/2024]
Abstract
Equivalent doses for the eye lenses, thyroid, and mammary glands were measured and compared between one adult and three pediatric anthropomorphic phantoms during chest computed tomography (CT) using 40 mm volume helical scan on the Aquilion ONE GENESIS Edition CT equipment. Placing an optically stimulated luminescence dosemeter (OSLD) on the eye lenses, thyroid, and mammary gland, we measured and compared the equivalent dose of OSLD among different phantoms during chest CT using a helical scan. Compared with adults, the equivalent doses to the eye lens, thyroid, and mammary glands were ~81%, 77%, and 63% lower in newborns, 1-year-olds, and 5-year-olds using comparable image noise during chest CT.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, 143, Iseharashi, Naka-gun, Kanagawa 259-1193, Japan
| | | | - Shuji Abe
- Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| |
Collapse
|
7
|
Masuda T, Funama Y, Nakaura T, Sato T, Kiguchi M, Oku T, Awai K. Usefulness of the superior orbitomeatal line without the lens included in the scan range at different tube voltage during pediatric head CT. RADIOLOGIA 2024; 66:403-409. [PMID: 39426809 DOI: 10.1016/j.rxeng.2023.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 02/09/2023] [Indexed: 10/21/2024]
Abstract
INTRODUCTION AND OBJECTIVES To compare the real time skin dosimeter values at lens between with the lens included in the scan range (orbitomeatal base line [OML]) or without the lens included in the scan range (superior orbitomeatal line [SOML]) at different tube voltages. MATERIALS AND METHODS We used three pediatric anthropomorphic phantoms with a 64 detector-row computed tomography (CT) scanner with the OML- or SOML-protocol at different tube voltages during the head CT. A real time skin dosimeter was inserted into the phantom center of the head, and surfaces of the lens. We compared the real time skin dosimeter values at lens between the OML- and SOML-protocol. RESULTS There were no significant differences in the real time skin dosimeter values for the head in the scan area for each phantom at different tube voltages between the OML- and SOML-protocol (p > 0.05 for all phantom). Compared with the OML protocol, it is possible to reduce the real time skin dosimeter values at lens by approximately 80% by using the SOML protocol (p < 0.05) at all tube voltages. Compared with the OML protocol, it is possible to reduce the real time skin dosimeter values at mammary gland by approximately 20% by using the SOML protocol (p < 0.05) at all tube voltages. CONCLUSIONS During the pediatric head CT examination, SOML protocol was possible to reduce the real time skin dosimeter values at lens by approximately 80% compared with OML protocol at all tube voltages.
Collapse
Affiliation(s)
- T Masuda
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Matsushima Kurashiki, Okayama, Japan.
| | - Y Funama
- Departamento de Física Médica, Facultad de Ciencias de la Vida, Universidad de Kumamoto, Kumamoto, Kumamoto, Japan
| | - T Nakaura
- Departamento de Radiología Diagnóstica, Escuela de Grado de Ciencias Médicas, Universidad de Kumamoto, Honjo, Kumamoto, Japan
| | - T Sato
- Departamento de Radiología Diagnóstica, Hospital General de Tsuchiya, Naka-ku, Hiroshima, Japan
| | - M Kiguchi
- Departamento de Radiología Diagnóstica, Escuela de Grado de Ciencias Biomédicas, Universidad de Hiroshima, Hiroshima, Hiroshima, Japan
| | - T Oku
- Departamento de Técnicos Radiológicos, Hospital General de Tsuchiya, Naka-ku, Hiroshima, Japan
| | - K Awai
- Departamento de Radiología Diagnóstica, Escuela de Grado de Ciencias Biomédicas, Universidad de Hiroshima, Hiroshima, Hiroshima, Japan
| |
Collapse
|
8
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Comparison of pediatric lens scattered dose measurements between axial 40-mm and helical 160-mm detector width computed tomography scan modes. Pediatr Radiol 2024; 54:1197-1204. [PMID: 38769141 DOI: 10.1007/s00247-024-05947-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Revised: 05/06/2024] [Accepted: 05/06/2024] [Indexed: 05/22/2024]
Abstract
BACKGROUND Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P<0.01). The median equivalent doses of eye lenses for the helical and axial scans were 0.12 and 0.07 mSv/mGy for the newborn, 0.07 and 0.05 mSv/mGy for the 1-year-old, and 0.14 and 0.12 mSv/mGy for the 5-year-old, respectively, when using the Aquilion ONE. With the Aquilion ONE, lens scatter doses for the helical scan were approximately 70%, 40%, and 30% higher in the newborn, 1-year-old, and 5-year-old phantoms, respectively, than those for the axial scan (P<0.01). CONCLUSIONS When using the Aquilion ONE, lens scatter doses for the helical scan were significantly higher in all three phantoms than those for the axial scan. In contrast, when using the Revolution CT, the lens scatter dose for the helical scan was significantly higher in the 5-year-old phantom than that for the axial scan. These results suggest that although scattered doses may vary with respect to the CT scanner and body size, they are generally lower in the case of axial scans.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, 701-0193, Okayama, Japan.
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, Kanagawa, Japan
| | | | - Shuji Abe
- Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
9
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Impact of beam collimation of z-overscanning on dose to the lens and thyroid gland in paediatric thoracic computed tomography imaging. Pediatr Radiol 2024; 54:758-763. [PMID: 38308740 DOI: 10.1007/s00247-024-05862-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 01/17/2024] [Accepted: 01/19/2024] [Indexed: 02/05/2024]
Abstract
BACKGROUND Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Matsushima, Kurashiki, Okayama, 288701-0193, Japan.
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, Hiroshima, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Hiroshima, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, Kanagawa, Japan
| | | | - Shuji Abe
- Department of Radiological Technology, Osaka College of High Technology, Osaka, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, Hiroshima, Japan
| |
Collapse
|
10
|
Masuda T, Takei Y, Arao S. Is the use of gonad protection protectors necessary during infants chest radiography? RADIOLOGIA 2024; 66:107-113. [PMID: 38614527 DOI: 10.1016/j.rxeng.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/21/2022] [Indexed: 04/15/2024]
Abstract
INTRODUCTION AND OBJECTIVES To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. MATERIALS AND METHODS Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. RESULTS The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00 μGy at newborn, and 10.00 and 0.00μGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00 μGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). CONCLUSIONS No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.
Collapse
Affiliation(s)
- T Masuda
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan.
| | - Y Takei
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan
| | - S Arao
- Departamento de Tecnología Radiológica, Facultad de Ciencia y Tecnología de la Salud, Universidad de Bienestar Médico de Kawasaki, Kurashiki, Okayama, Japan
| |
Collapse
|
11
|
Masuda T, Kiguchi M, Fujioka C, Oku T, Ishibashi T, Katsunuma Y, Yoshitake T, Abe S, Awai K. Effectiveness of low tube voltage scan in the exposure dose for lenses during paediatric thoracic CT examination: anthropomorphic phantoms study. RADIATION PROTECTION DOSIMETRY 2024; 200:143-148. [PMID: 37987195 DOI: 10.1093/rpd/ncad284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 10/04/2023] [Accepted: 10/30/2023] [Indexed: 11/22/2023]
Abstract
To determine whether using lower-tube voltage reduces the scattered dose for the lens during paediatric thoracic computed tomography (CT). Two paediatric anthropomorphic phantoms (ATOM Phantom, CIRS, Norfolk, Virginia, USA) representing a newborn and 5-year-old were placed on the gantry of CT scanner, and optically stimulated luminescence dosemeters were placed on the left and right lenses, in front of the left and right thyroid glands, in front of the left and right mammary glands, and in front of and behind the mammary gland level and we measured scattered dose of the optically stimulated luminescence dosemeter was compared for each phantom between 80 and 120 kVp. Significant differences were observed in the scatter doses for the lens between 80 and 120 kVp (p < 0.01). Compared with the 120 kVp scan, the scatter doses for the lens were ~15-40% lower in newborn and 5-year-olds using the 80 kVp scan during paediatric CT.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Masao Kiguchi
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Chikako Fujioka
- Department of Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Toru Ishibashi
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Yasushi Katsunuma
- Department of Radiological Technology, Tokai University Oiso Hospital, 143, Shimokasuya, Iseharashi, Kanagawa 259-1193, Japan
| | - Takayasu Yoshitake
- TOWCAR WORKS Co., Ltd Hoashi 233-1, Kusu-machi, Kusugun, Oita 879-4403, Japan
| | - Shuji Abe
- Department of Radiological Technologist, Osaka College of High Technology, 1-2-43, Miyahara, Yogogawa-ku, Osaka 532-0003, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Hiroshima University, 2-3, Kasumi, Minami-ku, Hiroshima 734-0037, Japan
| |
Collapse
|
12
|
Hazen P, Trossi-Torres G, Timsina R, Khadka NK, Mainali L. Association of Alpha-Crystallin with Human Cortical and Nuclear Lens Lipid Membrane Increases with the Grade of Cortical and Nuclear Cataract. Int J Mol Sci 2024; 25:1936. [PMID: 38339214 PMCID: PMC10855980 DOI: 10.3390/ijms25031936] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/29/2024] [Accepted: 02/03/2024] [Indexed: 02/12/2024] Open
Abstract
Eye lens α-crystallin has been shown to become increasingly membrane-bound with age and cataract formation; however, to our knowledge, no studies have investigated the membrane interactions of α-crystallin throughout the development of cataracts in separated cortical membrane (CM) and nuclear membrane (NM) from single human lenses. In this study, four pairs of human lenses from age-matched male and female donors and one pair of male lenses ranging in age from 64 to 73 years old (yo) were obtained to investigate the interactions of α-crystallin with the NM and CM throughout the progression of cortical cataract (CC) and nuclear cataract (NC) using the electron paramagnetic resonance spin-labeling method. Donor health history information (diabetes, smoker, hypertension, radiation treatment), sex, and race were included in the data analysis. The right eye lenses CM and NM investigated were 64 yo male (CC: 0), 68 yo male (CC: 3, NC: 2), 73 yo male (CC: 1, NC: 2), 68 yo female (CC: 3, NC: 2), and 73 yo female (CC: 1, NC: 3). Similarly, left eye lenses CM and NM investigated were 64 yo male (CC: 0), 68 yo male (CC: 3, NC: 2), 73 yo male (CC: 2, NC: 3), 68 yo female (CC: 3, NC: 2), and 73 yo female (CC: 1, NC: 3). Analysis of α-crystallin binding to male and female eye lens CM and NM revealed that the percentage of membrane surface occupied (MSO) by α-crystallin increases with increasing grade of CC and NC. The binding of α-crystallin resulted in decreased mobility, increased order, and increased hydrophobicity on the membrane surface in male and female eye lens CM and NM. CM mobility decreased with an increase in cataracts for both males and females, whereas the male lens NM mobility showed no significant change, while female lens NM showed increased mobility with an increase in cataract grade. Our data shows that a 68 yo female donor (long-term smoker, pre-diabetic, and hypertension; grade 3 CC) showed the largest MSO by α-crystallin in CM from both the left and right lens and had the most pronounced mobility changes relative to all other analyzed samples. The variation in cholesterol (Chol) content, size and amount of cholesterol bilayer domains (CBDs), and lipid composition in the CM and NM with age and cataract might result in a variation of membrane surface mobility, membrane surface hydrophobicity, and the interactions of α-crystallin at the surface of each CM and NM. These findings provide insight into the effect of decreased Chol content and the reduced size and amount of CBDs in the cataractous CM and NM with an increased binding of α-crystallin with increased CC and NC grade, which suggests that Chol and CBDs might be a key component in maintaining lens transparency.
Collapse
Affiliation(s)
- Preston Hazen
- Biomolecular Sciences Graduate Programs, Boise State University, Boise, ID 83725, USA; (P.H.); (G.T.-T.)
| | - Geraline Trossi-Torres
- Biomolecular Sciences Graduate Programs, Boise State University, Boise, ID 83725, USA; (P.H.); (G.T.-T.)
- Department of Physics, Boise State University, Boise, ID 83725, USA; (R.T.); (N.K.K.)
| | - Raju Timsina
- Department of Physics, Boise State University, Boise, ID 83725, USA; (R.T.); (N.K.K.)
| | - Nawal K. Khadka
- Department of Physics, Boise State University, Boise, ID 83725, USA; (R.T.); (N.K.K.)
| | - Laxman Mainali
- Biomolecular Sciences Graduate Programs, Boise State University, Boise, ID 83725, USA; (P.H.); (G.T.-T.)
- Department of Physics, Boise State University, Boise, ID 83725, USA; (R.T.); (N.K.K.)
| |
Collapse
|
13
|
Hu C, Liao Z, Zhang L, Ma Z, Xiao C, Shao S, Gao Y. Alleviation of Splenic Injury by CB001 after Low-Dose Irradiation Mediated by NLRP3/Caspase-1-BAX/Caspase-3 Axis. Radiat Res 2024; 201:126-139. [PMID: 38154483 DOI: 10.1667/rade-22-00053.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 12/12/2023] [Indexed: 12/30/2023]
Abstract
Low-dose radiation has been extensively employed in clinical practice, including tumor immunotherapy, chronic inflammation treatment and nidus screening. However, the damage on the spleen caused by low-dose radiation significantly increases the risk of late infection-related mortality, and there is currently no corresponding protective strategy. In the present study, a novel compound preparation named CB001 mainly constituted of Acanthopanax senticosus (AS) and Oldenlandia diffusa (OD) was developed to alleviate splenic injury caused by fractionated low-dose exposures. As our results show that, white pulp atrophy and the excessive apoptosis in spleen tissue induced by radiation exposure were significantly ameliorated by CB001. Mechanistically, BAX-caspase-3 signaling and nucleotide-binding domain and leucine-rich-repeat-containing family pyrin 3 (NLRP3) inflammasome signaling were demonstrated to be involved in the radio-protective activity of CB001 with the selective activators. Furthermore, the crosstalk between apoptosis signaling and NLRP3 inflammasome signaling in mediating the radio-protective activity of CB001 was clarified, in which the pro-apoptotic protein BAX but not the anti-apoptotic protein Bcl2 was found to be downstream of NLRP3. Our study demonstrated that the use of a novel drug product CB001 can potentially facilitate the alleviation of radiation-induced splenic injury for patients receiving medical imaging diagnosis or fractionated radiation therapy.
Collapse
Affiliation(s)
- Changkun Hu
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P.R. China
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| | - Zebin Liao
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| | - Liangliang Zhang
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| | - Zengchun Ma
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| | - Chengrong Xiao
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| | - Shuai Shao
- National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China
| | - Yue Gao
- State Key Laboratory of Component-based Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P.R. China
- Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, P.R. China
| |
Collapse
|
14
|
Kleiman NJ, Edmondson EF, Weil MM, Fallgren CM, King A, Schmidt C, Hall EJ. Radiation cataract in Heterogeneous Stock mice after γ-ray or HZE ion exposure. LIFE SCIENCES IN SPACE RESEARCH 2024; 40:97-105. [PMID: 38245354 PMCID: PMC10800003 DOI: 10.1016/j.lssr.2023.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 09/12/2023] [Accepted: 09/13/2023] [Indexed: 01/22/2024]
Abstract
Health effects of space radiation are a serious concern for astronauts on long-duration missions. The lens of the eye is one of the most radiosensitive tissues in the body and, therefore, ocular health risks for astronauts is a significant concern. Studies in humans and animals indicate that ionizing radiation exposure to the eye produces characteristic lens changes, termed "radiation cataract," that can affect visual function. Animal models of radiation cataractogenesis have previously utilized inbred mouse or rat strains. These studies were essential for determining morphological changes and dose-response relationships between radiation exposure and cataract. However, the relevance of these studies to human radiosensitivity is limited by the narrow phenotypic range of genetically homogeneous animal models. To model radiation cataract in genetically diverse populations, longitudinal cataract phenotyping was nested within a lifetime carcinogenesis study in male and female heterogeneous stock (HS/Npt) mice exposed to 0.4 Gy HZE ions (n = 609) or 3.0 Gy γ-rays (n = 602) and in unirradiated controls (n = 603). Cataractous change was quantified in each eye for up to 2 years using Merriam-Focht grading criteria by dilated slit lamp examination. Virtual Optomotry™ measurement of visual acuity and contrast sensitivity was utilized to assess visual function in a subgroup of mice. Prevalence and severity of posterior lens opacifications were 2.6-fold higher in HZE ion and 2.3-fold higher in γ-ray irradiated mice compared to unirradiated controls. Male mice were at greater risk for spontaneous and radiation associated cataracts. Risk for cataractogenesis was associated with family structure, demonstrating that HS/Npt mice are well-suited to evaluate genetic determinants of ocular radiosensitivity. Last, mice were extensively evaluated for cataract and tumor formation, which revealed an overlap between individual susceptibility to both cancer and cataract.
Collapse
Affiliation(s)
- Norman J Kleiman
- Department of Environmental Health Sciences, Eye Radiation and Environmental Research Laboratory, Columbia University, Mailman School of Public Health, 722 West 168th St., 11th Floor, New York, NY, 10032, United States.
| | - Elijah F Edmondson
- Department of Microbiology, Immunology and Pathology, Colorado State University, Fort Collins, CO, 80523, United States; Frederick National Laboratory for Cancer Research, Frederick, Maryland, 21702, United States
| | - Michael M Weil
- Department of Environment and Radiological Health Sciences, Colorado State University, Fort Collins, CO, 80523, United States
| | - Christina M Fallgren
- Department of Environment and Radiological Health Sciences, Colorado State University, Fort Collins, CO, 80523, United States
| | - Adam King
- Department of Clinical Sciences, Colorado State University, Fort Collins, CO, 80523, United States; MedVet Chicago, Chicago, IL, 60618, United States
| | - Catherine Schmidt
- Department of Clinical Sciences, Colorado State University, Fort Collins, CO, 80523, United States; Veterinary Eye Specialists, Thornwood, NY, 10594, , United States
| | - Eric J Hall
- Center for Radiological Research, Columbia University, College of Physicians and Surgeons, 630W. 168th St., New York, NY,10032, , United States
| |
Collapse
|
15
|
La Rocca M, Leonardi BF, Lo Greco MC, Marano G, Finocchiaro I, Iudica A, Milazzotto R, Liardo RLE, La Monaca VA, Salamone V, Basile A, Foti PV, Palmucci S, David E, Parisi S, Pontoriero A, Pergolizzi S, Spatola C. Radiotherapy of Orbital and Ocular Adnexa Lymphoma: Literature Review and University of Catania Experience. Cancers (Basel) 2023; 15:5782. [PMID: 38136328 PMCID: PMC10741683 DOI: 10.3390/cancers15245782] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 12/06/2023] [Accepted: 12/08/2023] [Indexed: 12/24/2023] Open
Abstract
Orbital and ocular adnexa lymphomas are rare neoplasms confined to the orbital region. The prognosis is generally favorable, with a high proportion of localized disease, indolent clinical course, prolonged disease-free intervals, and low lymphoma-related mortality rate. We report our experience on eleven patients with confirmed histological diagnosis of lymphoma stage IE-IIE, treated between 2010 and 2021 with radiotherapy alone or in association with chemotherapy or immunotherapy. Eight patients were treated with primary radiotherapy only, while three received previous systemic treatments. Six patients were treated with Proton beam therapy (PBT), and five with external beam radiotherapy (EBRT). The five-year local control rate was 98%; only one patient developed an out-of-field recurrence. We also conducted a comprehensive literature review using electronic databases (PubMed, EMBASE, and Cochrane Library). Articles were selected based on their pertinence to treatment of the ocular and adnexal lymphoma focusing on radiotherapy techniques (electron beam radiotherapy, photon beam radiotherapy, or proton beam radiotherapy), treatment total dose, fractionation schedule, early and late radio-induced toxicities, and patient's clinical outcome. Radiotherapy is an effective treatment option for orbital lymphoma, especially as standard treatment in the early stage of orbital lymphoma, with excellent local control rate and low rates of toxicity.
Collapse
Affiliation(s)
- Madalina La Rocca
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Barbara Francesca Leonardi
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Maria Chiara Lo Greco
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Giorgia Marano
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Irene Finocchiaro
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Arianna Iudica
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Roberto Milazzotto
- Radiation Oncology Unit, Department of Medical Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (R.M.); (R.L.E.L.); (V.A.L.M.); (V.S.)
| | - Rocco Luca Emanuele Liardo
- Radiation Oncology Unit, Department of Medical Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (R.M.); (R.L.E.L.); (V.A.L.M.); (V.S.)
| | - Viviana Anna La Monaca
- Radiation Oncology Unit, Department of Medical Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (R.M.); (R.L.E.L.); (V.A.L.M.); (V.S.)
| | - Vincenzo Salamone
- Radiation Oncology Unit, Department of Medical Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (R.M.); (R.L.E.L.); (V.A.L.M.); (V.S.)
| | - Antonio Basile
- Department of Medical Surgical Sciences and Advanced Technologies “GF Ingrassia”, University Hospital Policlinico “G. Rodolico-San Marco”, 95123 Catania, Italy; (A.B.); (P.V.F.); (S.P.)
- Radiology I Unit, Department of Medical Surgical Sciences and Advanced Technologies "G.F. Ingrassia", University of Catania, 95123 Catania, Italy;
| | - Pietro Valerio Foti
- Department of Medical Surgical Sciences and Advanced Technologies “GF Ingrassia”, University Hospital Policlinico “G. Rodolico-San Marco”, 95123 Catania, Italy; (A.B.); (P.V.F.); (S.P.)
- Radiology I Unit, Department of Medical Surgical Sciences and Advanced Technologies "G.F. Ingrassia", University of Catania, 95123 Catania, Italy;
| | - Stefano Palmucci
- Department of Medical Surgical Sciences and Advanced Technologies “GF Ingrassia”, University Hospital Policlinico “G. Rodolico-San Marco”, 95123 Catania, Italy; (A.B.); (P.V.F.); (S.P.)
- Radiology I Unit, Department of Medical Surgical Sciences and Advanced Technologies "G.F. Ingrassia", University of Catania, 95123 Catania, Italy;
| | - Emanuele David
- Radiology I Unit, Department of Medical Surgical Sciences and Advanced Technologies "G.F. Ingrassia", University of Catania, 95123 Catania, Italy;
| | - Silvana Parisi
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Antonio Pontoriero
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Stefano Pergolizzi
- Radiation Oncology Unit, Department of Biomedical, Dental and Morphological and Functional Imaging Sciences, University of Messina, 98122 Messina, Italy; (B.F.L.); (M.C.L.G.); (G.M.); (I.F.); (A.I.); (S.P.); (A.P.); (S.P.)
| | - Corrado Spatola
- Radiation Oncology Unit, Department of Medical Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (R.M.); (R.L.E.L.); (V.A.L.M.); (V.S.)
- Department of Medical Surgical Sciences and Advanced Technologies “GF Ingrassia”, University Hospital Policlinico “G. Rodolico-San Marco”, 95123 Catania, Italy; (A.B.); (P.V.F.); (S.P.)
- Radiology I Unit, Department of Medical Surgical Sciences and Advanced Technologies "G.F. Ingrassia", University of Catania, 95123 Catania, Italy;
| |
Collapse
|
16
|
Kinoshita K, Kodera S, Hatsusaka N, Egawa R, Takizawa H, Kubo E, Sasaki H, Hirata A. Association of nuclear cataract prevalence with UV radiation and heat load in lens of older people -five city study. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:123832-123842. [PMID: 37991619 DOI: 10.1007/s11356-023-31079-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Accepted: 11/13/2023] [Indexed: 11/23/2023]
Abstract
Epidemiological studies have reported that the frequency of nuclear cataracts (NUCs) is high among the elderly and in tropical countries. Ultraviolet (UV) irradiation and lens temperature are considered as key physical contributors, although their precise quantification is difficult. The aim of this study is to investigate the association of NUC prevalence with UV irradiation and heat load. First, we assessed the lens temperature using thermodynamic modeling considering the thermophysiological response. We then conducted a multivariate linear regression analysis for the epidemiological analysis of NUC prevalence across five cities. A strong correlation was observed between NUC prevalence and the combined effects of UV irradiation and cumulative equivalent minutes at 43 °C (CEM43°C) derived from the computed lens temperature (adjusted R2 = 0.933, p < 0.0001). Heat load significantly contributed to the prevalence at 52%, surpassing the contributions of UV irradiation (31%) and the decline in DNA repair capacity in the lens (17%). These results suggested that both UV radiation and heat load are associated with NUC, with heat load contributing more. Our findings provided important implications for future interventions, particularly in the context of global warming.
Collapse
Affiliation(s)
- Kotaro Kinoshita
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-Cho, Showa-Ku, Nagoya, Aichi, 466-8555, Japan
| | - Sachiko Kodera
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-Cho, Showa-Ku, Nagoya, Aichi, 466-8555, Japan
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan
| | - Natsuko Hatsusaka
- Department of Ophthalmology, Kanazawa Medical University, Ishikawa, Japan
| | - Ryusuke Egawa
- School of Engineering, Tokyo Denki University, Tokyo, Japan
| | | | - Eri Kubo
- Department of Ophthalmology, Kanazawa Medical University, Ishikawa, Japan
| | - Hiroshi Sasaki
- Department of Ophthalmology, Kanazawa Medical University, Ishikawa, Japan
| | - Akimasa Hirata
- Department of Electrical and Mechanical Engineering, Nagoya Institute of Technology, Gokiso-Cho, Showa-Ku, Nagoya, Aichi, 466-8555, Japan.
- Center of Biomedical Physics and Information Technology, Nagoya Institute of Technology, Nagoya, Japan.
| |
Collapse
|
17
|
Arao S, Masuda T, Oku T, Ono A, Okura Y. Utility of lower tube voltage scans in reducing exposure of healthcare workers within computed tomography room to scattered radiation. RADIATION PROTECTION DOSIMETRY 2023; 199:2338-2343. [PMID: 37646071 DOI: 10.1093/rpd/ncad240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 07/25/2023] [Accepted: 08/11/2023] [Indexed: 09/01/2023]
Abstract
The aim of this study was to estimate the effect of tube voltage on the scattered dose in a computed tomography (CT) room. To this end, we conducted experiments using anthropomorphic phantoms and a CT scanner at different tube voltages during CT. The scattered dose was measured using an electronic pocket dosemeter at 50-cm intervals from the centre of the gantry. The structure of the CT room was measured at 57 points (28 points in the front of the gantry (on the bed side), 6 points on the side of the gantry and 23 points behind the gantry) to be up to 200 cm. We compared the scattered dose distributions between 80 and 120 kVp at heights of 50, 100 and 150 cm above the floor surface. The scattered dose was reduced by ~30% when the tube voltage was reduced from 120 to 80 kVp.
Collapse
Affiliation(s)
- Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Takayuki Oku
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima, Hiroshima 730-8655, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288 Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yasuhiko Okura
- Department of Clinical Radiology, Faculty of Health Sciences, Hiroshima International University, 555-36 Kurosegakuendai, Higashihiroshima, Hiroshima 739-2695, Japan
| |
Collapse
|
18
|
Al-Choboq J, Mathis T, Restier-Verlet J, Sonzogni L, El Nachef L, Granzotto A, Bourguignon M, Foray N. The Radiobiological Characterization of Human and Porcine Lens Cells Suggests the Importance of the ATM Kinase in Radiation-Induced Cataractogenesis. Cells 2023; 12:2118. [PMID: 37626928 PMCID: PMC10453874 DOI: 10.3390/cells12162118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/14/2023] [Accepted: 08/17/2023] [Indexed: 08/27/2023] Open
Abstract
Studies about radiation-induced human cataractogenesis are generally limited by (1) the poor number of epithelial lens cell lines available (likely because of the difficulties of cell sampling and amplification) and (2) the lack of reliable biomarkers of the radiation-induced aging process. We have developed a mechanistic model of the individual response to radiation based on the nucleoshuttling of the ATM protein (RIANS). Recently, in the frame of the RIANS model, we have shown that, to respond to permanent endo- and exogenous stress, the ATM protein progressively agglutinates around the nucleus attracted by overexpressed perinuclear ATM-substrate protein. As a result, perinuclear ATM crowns appear to be an interesting biomarker of aging. The radiobiological characterization of the two human epithelial lens cell lines available and the four porcine epithelial lens cell lines that we have established showed delayed RIANS. The BFSP2 protein, found specifically overexpressed around the lens cell nucleus and interacting with ATM, may be a specific ATM-substrate protein facilitating the formation of perinuclear ATM crowns in lens cells. The perinuclear ATM crowns were observed inasmuch as the number of culture passages is high. Interestingly, 2 Gy X-rays lead to the transient disappearance of the perinuclear ATM crowns. Altogether, our findings suggest a strong influence of the ATM protein in radiation-induced cataractogenesis.
Collapse
Affiliation(s)
- Joëlle Al-Choboq
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| | - Thibaud Mathis
- Ophtalmology Department, Hospices Civils de Lyon, General University Hospital of Croix-Rousse, 103 Grande Rue Croix Rousse, 69004 Lyon, France;
- MATEIS Laboratory, CNRS UMR5510, INSA, Université Claude-Bernard Lyon 1, Campus de la Doua, 69100 Villeurbanne, France
| | - Juliette Restier-Verlet
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| | - Laurène Sonzogni
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| | - Laura El Nachef
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| | - Adeline Granzotto
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| | - Michel Bourguignon
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
- Department of Biophysics and Nuclear Medicine, Université Paris Saclay Versailles St Quentin-en-Yvelines, 78035 Versailles, France
| | - Nicolas Foray
- INSERM U1296 Unit “Radiation: Defense, Health, Environment”, 28 Rue Laennec, 69008 Lyon, France; (J.A.-C.); (J.R.-V.); (L.S.); (L.E.N.); (A.G.); (M.B.)
| |
Collapse
|
19
|
Shaaban SG, LeCompte MC, Kleinberg LR, Redmond KJ, Page BR. Recognition and Management of the Long-term Effects of Cranial Radiation. Curr Treat Options Oncol 2023; 24:880-891. [PMID: 37145381 DOI: 10.1007/s11864-023-01078-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/08/2023] [Indexed: 05/06/2023]
Abstract
OPINION STATEMENT Cranial radiation is ubiquitous in the treatment of primary malignant and benign brain tumors as well as brain metastases. Improvement in radiotherapy targeting and delivery has led to prolongation of survival outcomes. As long-term survivorship improves, we also focus on prevention of permanent side effects of radiation and mitigating the impact when they do occur. Such chronic treatment-related morbidity is a major concern with significant negative impact on patient's and caregiver's respective quality of life. The actual mechanisms responsible for radiation-induced brain injury remain incompletely understood. Multiple interventions have been introduced to potentially prevent, minimize, or reverse the cognitive deterioration. Hippocampal-sparing intensity modulated radiotherapy and memantine represent effective interventions to avoid damage to regions of adult neurogenesis. Radiation necrosis frequently develops in the high radiation dose region encompassing the tumor and surrounding normal tissue. The radiographic findings in addition to the clinical course of the patients' symptoms are taken into consideration to differentiate between tissue necrosis and tumor recurrence. Radiation-induced neuroendocrine dysfunction becomes more pronounced when the hypothalamo-pituitary (HP) axis is included in the radiation treatment field. Baseline and post-treatment evaluation of hormonal profile is warranted. Radiation-induced injury of the cataract and optic system can develop when these structures receive an amount of radiation that exceeds their tolerance. Special attention should always be paid to avoid irradiation of these sensitive structures, if possible, or minimize their dose to the lowest limit.
Collapse
Affiliation(s)
- Sherif G Shaaban
- Department of Radiation Oncology & Molecular Radiation Sciences, Johns Hopkins Medicine, 401 North Broadway, Suite 1440, Baltimore, MD, 21287, USA
| | - Michael C LeCompte
- Department of Radiation Oncology & Molecular Radiation Sciences, Johns Hopkins Medicine, 401 North Broadway, Suite 1440, Baltimore, MD, 21287, USA
| | - Lawrence R Kleinberg
- Department of Radiation Oncology & Molecular Radiation Sciences, Johns Hopkins Medicine, 401 North Broadway, Suite 1440, Baltimore, MD, 21287, USA
| | - Kristin J Redmond
- Department of Radiation Oncology & Molecular Radiation Sciences, Johns Hopkins Medicine, 401 North Broadway, Suite 1440, Baltimore, MD, 21287, USA
| | - Brandi R Page
- Department of Radiation Oncology-National Capitol Region, Johns Hopkins Medicine, 6420 Rockledge Drive Suite 1200, Bethesda, MD, 20817, USA.
| |
Collapse
|
20
|
Sannan NS. Assessment of aggregate index of systemic inflammation and systemic inflammatory response index in dry age-related macular degeneration: a retrospective study. Front Med (Lausanne) 2023; 10:1143045. [PMID: 37181369 PMCID: PMC10166806 DOI: 10.3389/fmed.2023.1143045] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 04/04/2023] [Indexed: 05/16/2023] Open
Abstract
Introduction Inflammation is known to contribute to the development of age-related macular degeneration (AMD). Several inflammatory indices derived from routine complete blood counts have been proposed as biomarkers in multiple disorders. Methods In this study, clinical and laboratory data were retrospectively collected from medical records to assess the aggregate index of systemic inflammation (AISI) and the systemic inflammatory response index (SIRI) as potential biomarkers of systemic inflammation in patients with early diagnosis of dry AMD. Results The study included 90 patients with dry AMD and 270 age/sex-matched patients with cataracts as a control group. There were no significant differences in the AISI and SIRI results between the cases and controls (p = 0.16 and 0.19, respectively). Conclusion This suggests that AISI and SIRI may be inadequate metrics for AMD or lack sensitivity in detecting inflammatory changes. Exploring other routine blood markers may help to identify and prevent the early stages of AMD.
Collapse
Affiliation(s)
- Naif S. Sannan
- Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud bin Abdulaziz University for Health Sciences, Jeddah, Saudi Arabia
- Biomedical Research Department, King Abdullah International Medical Research Center, Jeddah, Saudi Arabia
| |
Collapse
|
21
|
Uwineza A, Cummins I, Jarrin M, Kalligeraki AA, Barnard S, Mol M, Degani G, Altomare AA, Aldini G, Schreurs A, Balschun D, Ainsbury EA, Dias IHK, Quinlan RA. Identification and quantification of ionising radiation-induced oxysterol formation in membranes of lens fibre cells. ADVANCES IN REDOX RESEARCH 2023; 7:None. [PMID: 38798747 PMCID: PMC11112148 DOI: 10.1016/j.arres.2022.100057] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 12/06/2022] [Accepted: 12/13/2022] [Indexed: 05/29/2024]
Abstract
Ionising radiation (IR) is a cause of lipid peroxidation, and epidemiological data have revealed a correlation between exposure to IR and the development of eye lens cataracts. Cataracts remain the leading cause of blindness around the world. The plasma membranes of lens fibre cells are one of the most cholesterolrich membranes in the human body, forming lipid rafts and contributing to the biophysical properties of lens fibre plasma membrane. Liquid chromatography followed by mass spectrometry was used to analyse bovine eye lens lipid membrane fractions after exposure to 5 and 50 Gy and eye lenses taken from wholebody 2 Gy-irradiated mice. Although cholesterol levels do not change significantly, IR dose-dependant formation of the oxysterols 7β-hydroxycholesterol, 7-ketocholesterol and 5, 6-epoxycholesterol in bovine lens nucleus membrane extracts was observed. Whole-body X-ray exposure (2 Gy) of 12-week old mice resulted in an increase in 7β-hydroxycholesterol and 7-ketocholesterol in their eye lenses. Their increase regressed over 24 h in the living lens cortex after IR exposure. This study also demonstrated that the IR-induced fold increase in oxysterols was greater in the mouse lens cortex than the nucleus. Further work is required to elucidate the mechanistic link(s) between oxysterols and IR-induced cataract, but these data evidence for the first time that IR exposure of mice results in oxysterol formation in their eye lenses.
Collapse
Affiliation(s)
- Alice Uwineza
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
- Biophysical Sciences Institute, University of Durham, South Road, Durham D1 3LE, United Kingdom
| | - Ian Cummins
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
| | - Miguel Jarrin
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
- Biophysical Sciences Institute, University of Durham, South Road, Durham D1 3LE, United Kingdom
| | - Alexia A. Kalligeraki
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
- Biophysical Sciences Institute, University of Durham, South Road, Durham D1 3LE, United Kingdom
| | - Stephen Barnard
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
- Biophysical Sciences Institute, University of Durham, South Road, Durham D1 3LE, United Kingdom
- UK Health Security Agency, Cytogenetics and Pathology Group, Centre for Radiation, Chemical and Environmental Hazards Division, Chilton, Oxon OX11 0RQ, Didcot, United Kingdom
| | - Marco Mol
- Department of Pharmaceutical Sciences, Via Mangiagalli 25, Milano 20133, Italy
| | - Genny Degani
- Department of Biosciences, Via Celoria 26, Milano 20133, Italy
| | | | - Giancarlo Aldini
- Department of Pharmaceutical Sciences, Via Mangiagalli 25, Milano 20133, Italy
| | - An Schreurs
- Brain & Cognition, Leuven Brain Institute, KU Leuven, Leuven, Belgium
| | - Detlef Balschun
- Brain & Cognition, Leuven Brain Institute, KU Leuven, Leuven, Belgium
| | - Elizabeth A. Ainsbury
- UK Health Security Agency, Cytogenetics and Pathology Group, Centre for Radiation, Chemical and Environmental Hazards Division, Chilton, Oxon OX11 0RQ, Didcot, United Kingdom
| | - Irundika HK Dias
- Aston Medical School, Aston University, B4 7ET, Birmingham, United Kingdom
| | - Roy A. Quinlan
- Department of Biosciences, University of Durham, Upper Mountjoy Science Site, South Road, Durham DH1 3LE, United Kingdom
- Biophysical Sciences Institute, University of Durham, South Road, Durham D1 3LE, United Kingdom
- Department of Biological Structure, University of Washington, 1959 NE Pacific Street, Seattle, WA 98195, United States
| |
Collapse
|
22
|
Chauhan V, Yu J, Vuong N, Haber LT, Williams A, Auerbach SS, Beaton D, Wang Y, Stainforth R, Wilkins RC, Azzam EI, Richardson RB, Khan MGM, Jadhav A, Burtt JJ, Leblanc J, Randhawa K, Tollefsen KE, Yauk CL. Considerations for application of benchmark dose modeling in radiation research: workshop highlights. Int J Radiat Biol 2023; 99:1320-1331. [PMID: 36881459 DOI: 10.1080/09553002.2023.2181998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Revised: 01/18/2023] [Accepted: 02/06/2023] [Indexed: 02/24/2023]
Abstract
BACKGROUND Exposure to different forms of ionizing radiation occurs in diverse occupational, medical, and environmental settings. Improving the accuracy of the estimated health risks associated with exposure is therefore, essential for protecting the public, particularly as it relates to chronic low dose exposures. A key aspect to understanding health risks is precise and accurate modeling of the dose-response relationship. Toward this vision, benchmark dose (BMD) modeling may be a suitable approach for consideration in the radiation field. BMD modeling is already extensively used for chemical hazard assessments and is considered statistically preferable to identifying low and no observed adverse effects levels. BMD modeling involves fitting mathematical models to dose-response data for a relevant biological endpoint and identifying a point of departure (the BMD, or its lower bound). Recent examples in chemical toxicology show that when applied to molecular endpoints (e.g. genotoxic and transcriptional endpoints), BMDs correlate to points of departure for more apical endpoints such as phenotypic changes (e.g. adverse effects) of interest to regulatory decisions. This use of BMD modeling may be valuable to explore in the radiation field, specifically in combination with adverse outcome pathways, and may facilitate better interpretation of relevant in vivo and in vitro dose-response data. To advance this application, a workshop was organized on June 3rd, 2022, in Ottawa, Ontario that brought together BMD experts in chemical toxicology and the radiation scientific community of researchers, regulators, and policy-makers. The workshop's objective was to introduce radiation scientists to BMD modeling and its practical application using case examples from the chemical toxicity field and demonstrate the BMDExpress software using a radiation dataset. Discussions focused on the BMD approach, the importance of experimental design, regulatory applications, its use in supporting the development of adverse outcome pathways, and specific radiation-relevant examples. CONCLUSIONS Although further deliberations are needed to advance the use of BMD modeling in the radiation field, these initial discussions and partnerships highlight some key steps to guide future undertakings related to new experimental work.
Collapse
Affiliation(s)
- Vinita Chauhan
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Canada
| | - Jihang Yu
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
| | - Ngoc Vuong
- Radiation Protection Bureau, Health Canada, Ottawa, Canada
| | - Lynne T Haber
- Department of Environmental and Public Health Sciences, Risk Science Center, University of Cincinnati, Cincinnati, OH, USA
| | - Andrew Williams
- Environmental Health Science and Research Bureau, Health Science and Research Bureau, Health Canada, Ottawa, Canada
| | - Scott S Auerbach
- National Institute of Environmental Health Sciences, Research Triangle Park, NC, USA
| | - Danielle Beaton
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
| | - Yi Wang
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
- Department of Biochemistry, Microbiology and Immunology, University of Ottawa, Ottawa, Canada
| | | | - Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Canada
| | - Edouard I Azzam
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
- Department of Radiology, New Jersey Medical School, Rutgers University, Newark, NJ, USA
| | - Richard B Richardson
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
- Medical Physics Unit, McGill University, Montreal, QC, Canada
| | | | - Ashok Jadhav
- Radiobiology and Health Branch, Canadian Nuclear Laboratories, Chalk River, Canada
| | - Julie J Burtt
- Directorate of Environmental and Radiation Protection and Assessment, Canadian Nuclear Safety Commission, Ottawa, Canada
| | - Julie Leblanc
- Directorate of Environmental and Radiation Protection and Assessment, Canadian Nuclear Safety Commission, Ottawa, Canada
| | - Kristi Randhawa
- Directorate of Environmental and Radiation Protection and Assessment, Canadian Nuclear Safety Commission, Ottawa, Canada
| | - Knut Erik Tollefsen
- Norwegian Institute for Water Research (NIVA), Oslo, Norway
- Norwegian University of Life Sciences (NMBU), Ås, Norway
- Centre for Environmental Radioactivity, Norwegian University of Life Sciences (NMBU), Ås, Norway
| | - Carole L Yauk
- Department of Biology, University of Ottawa, Ottawa, Canada
| |
Collapse
|
23
|
In Reply to Elmali and Yazici. Int J Radiat Oncol Biol Phys 2023; 115:810-811. [PMID: 36725170 DOI: 10.1016/j.ijrobp.2022.10.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 01/31/2023]
|
24
|
Taysi S, Algburi FS, Taysi ME, Caglayan C. Caffeic acid phenethyl ester: A review on its pharmacological importance, and its association with free radicals, COVID-19, and radiotherapy. Phytother Res 2023; 37:1115-1135. [PMID: 36562210 PMCID: PMC9880688 DOI: 10.1002/ptr.7707] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 11/04/2022] [Accepted: 11/11/2022] [Indexed: 12/24/2022]
Abstract
Caffeic acid phenethyl ester (CAPE), a main active component of propolis and a flavonoid, is one of the natural products that has attracted attention in recent years. CAPE, which has many properties such as anti-cancer, anti-inflammatory, antioxidant, antibacterial and anti-fungal, has shown many pharmacological potentials, including protective effects on multiple organs. Interestingly, molecular docking studies showed the possibility of binding of CAPE with replication enzyme. In addition, it was seen that in order to increase the binding security of the replication enzyme and CAPE, modifications can be made at three sites on the CAPE molecule, which leads to the possibility of the compound working more powerfully and usefully to prevent the proliferation of cancer cells and reduce its rate. Also, it was found that CAPE has an inhibitory effect against the main protease enzyme and may be effective in the treatment of SARS-CoV-2. This review covers in detail the importance of CAPE in alternative medicine, its pharmacological value, its potential as a cancer anti-proliferative agent, its dual role in radioprotection and radiosensitization, and its use against coronavirus disease 2019 (COVID-19).
Collapse
Affiliation(s)
- Seyithan Taysi
- Department of Medical Biochemistry, Medical School, Gaziantep University, Gaziantep, Turkey
| | - Firas Shawqi Algburi
- Department of Medical Biochemistry, Medical School, Gaziantep University, Gaziantep, Turkey.,Department of Biology, College of Science, Tikrit University, Tikrit, Iraq.,College of Dentistry, Al-Kitab University, Altun Kupri, Iraq
| | - Muhammed Enes Taysi
- Department of Emergency Medicine, Medical School, Bolu Izzet Baysal University-Bolu, Bolu, Turkey
| | - Cuneyt Caglayan
- Department of Medical Biochemistry, Medical School, Bilecik Seyh Edebali University, Bilecik, Turkey
| |
Collapse
|
25
|
Abstract
PURPOSE Cataract (opacification of the ocular lens) is a typical tissue reaction (deterministic effect) following ionizing radiation exposure, for which prevention dose limits have been recommended in the radiation protection system. Manifestations of radiation cataracts can vary among individuals, but such potential individual responses remain uncharacterized. Here we review relevant literature and discuss implications for radiation protection. This review assesses evidence for significant modification of radiation-induced cataractogenesis by age at exposure, sex and genetic factors based on current scientific literature. CONCLUSIONS In addition to obvious physical factors (e.g. dose, dose rate, radiation quality, irradiation volume), potential factors modifying individual responses for radiation cataracts include sex, age and genetics, with comorbidity and coexposures also having important roles. There are indications and preliminary data identifying such potential modifiers of radiation cataract incidence or risk, although no firm conclusions can yet be drawn. Further studies and a consensus on the evidence are needed to gain deeper insights into factors determining individual responses regarding radiation cataracts and the implications for radiation protection.
Collapse
Affiliation(s)
- Stephen G R Barnard
- UK Health Security Agency (UKHSA), Radiation, Chemical and Environmental Hazards Division (RCEHD), Didcot, UK
| | - Nobuyuki Hamada
- Biology and Environmental Chemistry Division, Sustainable System Research Laboratory, Central Research Institute of Electric Power Industry (CRIEPI), Tokyo, Japan
| |
Collapse
|
26
|
Hattori K, Inaba Y, Kato T, Fujisawa M, Yasuno H, Yamada A, Haga Y, Suzuki M, Zuguchi M, Chida K. Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff. SENSORS (BASEL, SWITZERLAND) 2023; 23:512. [PMID: 36617110 PMCID: PMC9823962 DOI: 10.3390/s23010512] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/20/2022] [Accepted: 12/28/2022] [Indexed: 06/01/2023]
Abstract
In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafeTM) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <±20% between 50 and 110 kV. Dose linearity was good (R2 = 1.00); a slight dose-rate dependency (~20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180°) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications.
Collapse
Affiliation(s)
- Kenshin Hattori
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Yohei Inaba
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
- Department of Radiation Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 468-1 Aramaki Aza-Aoba, Aoba-ku, Sendai 980-0845, Japan
| | - Toshiki Kato
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Masaki Fujisawa
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Hikaru Yasuno
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Ayumi Yamada
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Yoshihiro Haga
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
- Department of Radiology, Sendai Kousei Hospital, 4-5 Hirose-machi, Aoba-ku, Sendai 980-0873, Japan
| | - Masatoshi Suzuki
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
- Department of Radiation Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 468-1 Aramaki Aza-Aoba, Aoba-ku, Sendai 980-0845, Japan
| | - Masayuki Zuguchi
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
| | - Koichi Chida
- Course of Radiological Technology, Health Sciences, Graduate School of Medicine, Tohoku University, 2-1 Seiryo, Aoba-ku, Sendai 980-8575, Japan
- Department of Radiation Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 468-1 Aramaki Aza-Aoba, Aoba-ku, Sendai 980-0845, Japan
| |
Collapse
|
27
|
Yokoyama S, Hamada N, Tsujimura N, Kunugita N, Nishida K, Ezaki I, Kato M, Okubo H. Regulatory implementation of the occupational equivalent dose limit for the lens of the eye and underlying relevant efforts in Japan. Int J Radiat Biol 2023; 99:604-619. [PMID: 35980737 DOI: 10.1080/09553002.2022.2115160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
In April 2011, the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens. Such a new occupational lens dose limit has thus far been implemented in many countries, and there are extensive discussions toward its regulatory implementation in other countries. In Japan, discussions in the Japan Health Physics Society (JHPS) began in April 2013 and in Radiation Council in July 2017, and the new occupational lens dose limit was implemented into regulation in April 2021. To share our experience, we have published a series of papers summarizing situations in Japan: the first paper based on information available by early 2017, and the second paper by early 2019. This paper (our third paper of this series) aims to review updated information available by mid-2022, such as regarding regulatory implementation of the new occupational lens dose limit, recent discussions by relevant ministries based on the opinion from the council, establishment process of safety and health management systems, the JHPS guidelines on lens dose monitoring and radiation safety, voluntary countermeasures of the licensees, development of lens dose calibration method, and recent studies on exposure of the lens in nuclear workers and biological effect on the lens.
Collapse
Affiliation(s)
- Sumi Yokoyama
- Research Promotion Headquarters, Fujita Health University, Aichi, Japan
| | - Nobuyuki Hamada
- Biology and Environmental Chemistry Division, Sustainable System Research Laboratory, Central Research Institute of Electric Power Industry (CRIEPI), Tokyo, Japan
| | - Norio Tsujimura
- Radiation Protection Department, Japan Atomic Energy Agency, Ibaraki, Japan
| | - Naoki Kunugita
- School of Health Sciences, University of Occupational and Environmental Health, Fukuoka, Japan
| | - Kazutaka Nishida
- Radiological Management Group, Kansai Electric Power Co., Inc, Fukui, Japan
| | - Iwao Ezaki
- Technical Group, Nuclear Power Plant Business Headquarters, Chiyoda Technol Corporation, Tokyo, Japan
| | - Masahiro Kato
- Ionizing Radiation Standards Group, National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology, Ibaraki, Japan
| | - Hideki Okubo
- Radiological Health and Safety Center Nuclear Safe Management Department, Tokyo Electric Power Company Holdings, Inc, Tokyo, Japan
| |
Collapse
|
28
|
Koterov AN, Tukov AR, Ushenkova LN, Kalinina MV, Biryukov AP. Average Accumulated Radiation Doses for Global Nuclear Workers: Low Doses, Low Effects, and Comparison with Doses for Medical Radiologists. BIOL BULL+ 2022. [DOI: 10.1134/s106235902212007x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
29
|
Abstract
The benefit of radiation is immense in the field of gastroenterology. Radiation is used daily in different gastrointestinal imaging and diagnostic and therapeutic interventional procedures. Radiotherapy is one of the primary modalities of treatment of gastrointestinal malignancies. There are various modalities of radiotherapy. Radiotherapy can injure malignant cells by directly damaging DNA, RNA, proteins, and lipids and indirectly by forming free radicals. External beam radiation, internal beam radiation and radio-isotope therapy are the major ways of delivering radiation to the malignant tissue. Radiation can also cause inflammation, fibrosis, organ dysfunction, and malignancy. Patients with repeated exposure to radiation for diagnostic imaging and therapeutic procedures are at slightly increased risk of malignancy. Gastrointestinal endoscopists performing fluoroscopy-guided procedures are also at increased risk of malignancy and cataract formation. The radiological protection society recommends certain preventive and protective measures to avoid side effects of radiation. Gastrointestinal complications related to radiation therapy for oncologic processes, and exposure risks for patients and health care providers involved in diagnostic or therapeutic imaging will be discussed in this review.
Collapse
Affiliation(s)
- Monjur Ahmed
- Division of Gastroenterology and Hepatology, Thomas Jefferson University, Philadelphia, PA 19107, USA
| | - Razin Ahmed
- California Cancer Associates for Research and Excellence, Fresno, CA, USA
| |
Collapse
|
30
|
Masuda T, Takei Y, Arao S. ¿Es necesario utilizar protectores de gónadas durante la realización de radiografías de tórax en los lactantes? RADIOLOGIA 2022. [DOI: 10.1016/j.rx.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
31
|
Jungi S, Ante M, Geisbüsch P, Hoedlmoser H, Kleinau P, Böckler D. Protected and Unprotected Radiation Exposure to the Eye Lens During Endovascular Procedures in Hybrid Operating Rooms. Eur J Vasc Endovasc Surg 2022; 64:567-572. [PMID: 35760276 DOI: 10.1016/j.ejvs.2022.06.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 04/22/2022] [Accepted: 06/19/2022] [Indexed: 01/12/2023]
Abstract
OBJECTIVE Radiation cataract has been observed at lower doses than previously thought, therefore the annual limit for equivalent dose to the eye lens has been reduced from 150 to 20 mSv. This study evaluated radiation exposure to the eye lens of operators working in a hybrid operating room before and after implementation of a dose reduction program. METHODS From April to October 2019, radiation exposure to the first operator was measured during all consecutive endovascular procedures performed in the hybrid operating room using BeOSL Hp(3) eye lens dosimeters placed both outside and behind the lead glasses (0.75 mm lead equivalent). Measured values were compared with data from a historic control group from the same hospital before implementation of the dose reduction program. RESULTS A total of 181 consecutive patients underwent an endovascular procedure in the hybrid operating room. The median unprotected eye lens dose (outside lead glasses) of the main operator was 0.049 mSv for endovascular aortic repair (EVAR) (n = 30), 0.042 mSv for thoracic endovascular aortic repair (TEVAR) (n = 23), 0.175 mSv for complex aortic fenestrated or branched endovascular procedures (F/BEVAR; n = 15), and 0.042 mSv for peripheral interventions (n = 80). Compared with the control period, EVAR had 75% lower, TEVAR 79% lower, and F/BEVAR 55% lower radiation exposure to the unprotected eye lens of the first operator. The lead glasses led to a median reduction in the exposure to the eye lens by a factor of 3.4. CONCLUSION The implementation of a dose reduction program led to a relevant reduction in radiation exposure to the head and eye lens of the first operator in endovascular procedures. With optimum radiation protection measures, including a ceiling mounted shield and lead glasses, more than 440 EVARs, 280 TEVARs, or 128 FEVARs could be performed per year before the dose limit for the eye lens of 20 mSv was reached.
Collapse
Affiliation(s)
- Silvan Jungi
- Department of Vascular and Endovascular Surgery, University Hospital of Heidelberg, Heidelberg, Germany; Department of Vascular Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Marius Ante
- Department of Vascular and Endovascular Surgery, University Hospital of Heidelberg, Heidelberg, Germany
| | - Philipp Geisbüsch
- Department of Vascular and Endovascular Surgery, University Hospital of Heidelberg, Heidelberg, Germany
| | | | | | - Dittmar Böckler
- Department of Vascular and Endovascular Surgery, University Hospital of Heidelberg, Heidelberg, Germany.
| |
Collapse
|
32
|
Masuda T, Funama Y, Nakaura T, Sato T, Urayama K, Kiguchi M, Oku T, Arao S, Ono A, Hiratsuka J, Awai K. COMPARISON OF PEDIATRIC LENS DOSE MEASUREMENTS BETWEEN AXIAL SCAN MODE WITHOUT ACTIVE COLLIMATOR AND HELICAL SCAN MODE WITH ACTIVE COLLIMATOR BY USING A 64 DETECTOR-ROW COMPUTED TOMOGRAPHY SCANNER. RADIATION PROTECTION DOSIMETRY 2022; 198:1522-1527. [PMID: 36193882 DOI: 10.1093/rpd/ncac196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/11/2022] [Accepted: 09/06/2022] [Indexed: 06/16/2023]
Abstract
To investigate the pediatric eye lens entrance surface dose for both axial scan modes without an active collimator and helical scan modes with an active collimator on 64 detector-row computed tomography (CT) scanner. We used three pediatric anthropomorphic phantoms with axial and helical scan modes from the superior orbitomeatal line to the crown of the head. We compared the measured dose values of the real-time skin dosemeter at the surfaces of the lens and the image noise at different scan modes. The median measured dose values for the lens of newborn, 1-year-old and the 5-year-old phantom were 31.3, 0.97 and 0.65 mGy, respectively, in the axial scan mode and 0.89, 1.21 and 0.71 mGy, respectively, in the helical scan mode. Compared with helical scans with an active collimators, axial scans can reduce the lens dose by ∼10% during head CT on 64 detector-row CT scanner without deterioration of image noise.
Collapse
Affiliation(s)
- Takanori Masuda
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Yoshinori Funama
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan
| | - Tomoyasu Sato
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Kotaro Urayama
- Department of Pediatric Cardiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Masao Kiguchi
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| | - Takayuki Oku
- Department of Radiological Technologist, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan
| | - Shinichi Arao
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Atsushi Ono
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Junichi Hiratsuka
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan
| | - Kazuo Awai
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Kasumi 1-2-3 Minami-ku, Hiroshima 734-8551, Japan
| |
Collapse
|
33
|
Daryoush JR, Lancaster AJ, Frandsen JJ, Gililland JM. Occupational Hazards to the Joint Replacement Surgeon: Radiation Exposure. J Arthroplasty 2022; 37:1464-1469. [PMID: 35247485 DOI: 10.1016/j.arth.2022.02.095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 02/22/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Intraoperative fluoroscopy is an essential tool to assist orthopedic surgeons in accurately and safely implanting hardware. In arthroplasty cases, its use is on the rise with the increasing popularity of the direct anterior (DA) approach for THA. However, exposure of ionizing radiation poses a potential health risk to surgeons. While the benefits of intraoperative fluoroscopy in DA THA is becoming clearer, and are well-described in the literature, the potential health dangers associated with career-long cumulative radiation exposure are rarely discussed. METHODS In this article, we review the available literature to discuss radiation safety in orthopedics with a focus on total joint arthroplasty. We present the basic science of radiation, discuss the amount of radiation exposure in orthopedic surgery, and review the potential health risks associated with long-term exposure. CONCLUSION Overall, the radiation dose exposure to arthroplasty surgeons is low and within recommendations for occupation exposure limits. However, due to the stochastic health impacts of ionizing radiation, there is no threshold dose below which radiation exposure is truly safe. Therefore, it is imperative that surgeons practice proper fluoroscopy safety habits, such as wearing proper protective equipment, minimizing fluoroscopy time and magnification, and maximizing distance from the radiation source to minimize the life-long cumulative radiation exposure and associated health risks.
Collapse
Affiliation(s)
- Joshua R Daryoush
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| | - Alex J Lancaster
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| | - Jeffrey J Frandsen
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| | - Jeremy M Gililland
- Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT
| |
Collapse
|
34
|
Miyaji N, Miwa K, Iimori T, Wagatsuma K, Tsushima H, Yokotsuka N, Murata T, Kasahara T, Terauchi T. Determination of a reliable assessment for occupational eye lens dose in nuclear medicine. J Appl Clin Med Phys 2022; 23:e13713. [PMID: 35775691 PMCID: PMC9359038 DOI: 10.1002/acm2.13713] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Revised: 05/31/2022] [Accepted: 06/14/2022] [Indexed: 11/29/2022] Open
Abstract
The most recent statement published by the International Commission on Radiological Protection describes a reduction in the maximum allowable occupational eye lens dose from 150 to 20 mSv/year (averaged over 5‐year periods). Exposing the eye lens to radiation is a concern for nuclear medicine staff who handle radionuclide tracers with various levels of photon energy. This study aimed to define the optimal dosimeter and means of measuring the amount of exposure to which the eye lens is exposed during a routine nuclear medicine practice. A RANDO human phantom attached to Glass Badge and Luminess Badge for body or neck, DOSIRIS and VISION for eyes, and nanoDot for body, neck, and eyes was exposed to 99mTc, 123I, and 18F radionuclides. Sealed syringe sources of each radionuclide were positioned 30 cm from the abdomen of the phantom. Estimated exposure based on measurement conditions (i.e., air kerma rate constants, conversion coefficient, distance, activity, and exposure time) was compared measured dose equivalent of each dosimeter. Differences in body, neck, and eye lens dosimeters were statistically analyzed. The 10‐mm dose equivalent significantly differed between the Glass Badge and Luminess Badge for the neck, but these were almost equivalent at the body. The 0.07‐mm dose equivalent for the nanoDot dosimeters was greatly overestimated compared to the estimated exposure of 99mTc and 123I radionuclides. Measured dose equivalents of exposure significantly differed between the body and eye lens dosimeters with respect to 18F. Although accurately measuring radiation exposure to the eye lenses of nuclear medicine staff is conventionally monitored using dosimeters worn on the chest or abdomen, eye lens dosimeters that provide a 3‐mm dose equivalent near the eye would be a more reliable means of assessing radiation doses in the mixed radiation environment of nuclear medicine.
Collapse
Affiliation(s)
- Noriaki Miyaji
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| | - Kenta Miwa
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
| | - Takashi Iimori
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | - Kei Wagatsuma
- School of Allied Health Science, Kitasato University, Kanagawa, Japan
| | - Hiroyuki Tsushima
- Department of Radiological Technology, Faculty of Health Sciences, Kobe Tokiwa University, Hyogo, Japan
| | - Noriyo Yokotsuka
- Department of Radiological Technology, Faculty of Medical Technology, Teikyo University, Tokyo, Japan
| | - Taisuke Murata
- Department of Radiology, Chiba University Hospital, Chiba, Japan
| | | | - Takashi Terauchi
- Department of Nuclear Medicine, Cancer Institute Hospital of Japanese Foundation for Cancer Research, Tokyo, Japan
| |
Collapse
|
35
|
Little MP, Brenner AV, Grant EJ, Sugiyama H, Preston DL, Sakata R, Cologne J, Velazquez-Kronen R, Utada M, Mabuchi K, Ozasa K, Olson JD, Dugan GO, Pazzaglia S, Cline JM, Applegate KE. Age effects on radiation response: summary of a recent symposium and future perspectives. Int J Radiat Biol 2022; 98:1673-1683. [PMID: 35394411 PMCID: PMC9626395 DOI: 10.1080/09553002.2022.2063962] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/25/2022] [Accepted: 03/29/2022] [Indexed: 10/18/2022]
Abstract
One of the principal uncertainties when estimating population risk of late effects from epidemiological data is that few radiation-exposed cohorts have been followed up to extinction. Therefore, the relative risk model has often been used to estimate radiation-associated risk and to extrapolate risk to the end of life. Epidemiological studies provide evidence that children are generally at higher risk of cancer induction than adults for a given radiation dose. However, the strength of evidence varies by cancer site and questions remain about site-specific age at exposure patterns. For solid cancers, there is a large body of evidence that excess relative risk (ERR) diminishes with increasing age at exposure. This pattern of risk is observed in the Life Span Study (LSS) as well as in other radiation-exposed populations for overall solid cancer incidence and mortality and for most site-specific solid cancers. However, there are some disparities by endpoint in the degree of variation of ERR with exposure age, with some sites (e.g., colon, lung) in the LSS incidence data showing no variation, or even increasing ERR with increasing age at exposure. The pattern of variation of excess absolute risk (EAR) with age at exposure is often similar, with EAR for solid cancers or solid cancer mortality decreasing with increasing age at exposure in the LSS. We shall review the human data from the Japanese LSS cohort, and a variety of other epidemiological data sets, including a review of types of medical diagnostic exposures, also some radiobiological animal data, all bearing on the issue of variations of radiation late-effects risk with age at exposure and with attained age. The paper includes a summary of several oral presentations given in a Symposium on "Age effects on radiation response" as part of the 67th Annual Meeting of the Radiation Research Society, held virtually on 3-6 October 2021.
Collapse
Affiliation(s)
- Mark P. Little
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD, USA
| | | | - Eric J. Grant
- Radiation Effects Research Foundation, Hiroshima, Japan
| | | | | | - Ritsu Sakata
- Radiation Effects Research Foundation, Hiroshima, Japan
| | - John Cologne
- Radiation Effects Research Foundation, Hiroshima, Japan
| | - Raquel Velazquez-Kronen
- Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH), Cincinnati, OH, USA
| | - Mai Utada
- Radiation Effects Research Foundation, Hiroshima, Japan
| | - Kiyohiko Mabuchi
- Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD, USA
| | - Kotaro Ozasa
- Radiation Effects Research Foundation, Hiroshima, Japan
| | - John D. Olson
- Wake Forest University School of Medicine, Winston-Salem, NC, USA
| | - Gregory O. Dugan
- Wake Forest University School of Medicine, Winston-Salem, NC, USA
| | - Simonetta Pazzaglia
- Laboratory of Biomedical Technologies, Agenzia Nazionale per le Nuove Tecnologie, l’Energia e lo Sviluppo Economico Sostenibile (ENEA), Rome, Italy
| | - J. Mark Cline
- Wake Forest University School of Medicine, Winston-Salem, NC, USA
| | | |
Collapse
|
36
|
Miura K, Coroneo M, Dusingize JC, Olsen CM, Tinker R, Karipidis K, Hosegood I, Green AC. Prevalence of cataract among Australian commercial airline pilots. ARCHIVES OF ENVIRONMENTAL & OCCUPATIONAL HEALTH 2022; 78:7-13. [PMID: 35343880 DOI: 10.1080/19338244.2022.2056110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Because little is known about cataract in pilots, we estimated prevalence by anonymously ascertaining all commercial airline pilots diagnosed with cataract 2011-2016 using the electronic Medical Records System of the Australian Civil Aviation Safety Authority. Of 14,163 Australian male commercial pilots licensed in 2011, 1286 aged ≥60 had biennial eye examinations showing a cataract prevalence of 11.6%. Among 12,877 pilots aged <60, based on compulsory eye examinations only when first licensed, prevalence was 0.5%. There was no significant difference by ambient ultraviolet (UV) radiation levels in state of residence though lowest prevalence was seen in the low-UV state of Victoria. Most cataract in pilots ≥60 years was bilateral and of mild severity, while cataract in pilots <60 were more likely to be unilateral and of greater severity.
Collapse
Affiliation(s)
- Kyoko Miura
- Population Health Department, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
- Faculty of Medicine, the University of Queensland, Brisbane, Queensland, Australia
| | - Minas Coroneo
- Department of Ophthalmology, University of New South Wales at Prince of Wales Hospital, Sydney, Australia
| | - Jean Claude Dusingize
- Population Health Department, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
| | - Catherine M Olsen
- Population Health Department, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
- Faculty of Medicine, the University of Queensland, Brisbane, Queensland, Australia
| | - Rick Tinker
- Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria, Australia
| | - Ken Karipidis
- Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Victoria, Australia
| | - Ian Hosegood
- Qantas Airlines Limited, Mascot, Sydney, Australia
| | - Adèle C Green
- Population Health Department, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
- CRUK Manchester Institute and Faculty of Biology Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK
| |
Collapse
|
37
|
Measurement of neutron equivalent dose in the thyroid, chiasma, and lens for patients undergoing pelvic radiotherapy: A phantom study. Appl Radiat Isot 2022; 184:110188. [DOI: 10.1016/j.apradiso.2022.110188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 01/18/2022] [Accepted: 03/04/2022] [Indexed: 11/20/2022]
|
38
|
Li LR, Sethi G, Zhang X, Liu CL, Huang Y, Liu Q, Ren BX, Tang FR. The neuroprotective effects of icariin on ageing, various neurological, neuropsychiatric disorders, and brain injury induced by radiation exposure. Aging (Albany NY) 2022; 14:1562-1588. [PMID: 35165207 PMCID: PMC8876913 DOI: 10.18632/aging.203893] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/08/2022] [Indexed: 11/25/2022]
Abstract
Epimedium brevicornum Maxim, a Traditional Chinese Medicine, has been used for the treatment of impotence, sinew and bone disorders, “painful impediment caused by wind-dampness,” numbness, spasms, hypertension, coronary heart disease, menopausal syndrome, bronchitis, and neurasthenia for many years in China. Recent animal experimental studies indicate that icariin, a major bioactive component of epimedium may effectively treat Alzheimer’s disease, cerebral ischemia, depression, Parkinson’s disease, multiple sclerosis, as well as delay ageing. Our recent study also suggested that epimedium extract could exhibit radio-neuro-protective effects and prevent ionizing radiation-induced impairment of neurogenesis. This paper reviewed the pharmacodynamics of icariin in treating different neurodegenerative and neuropsychiatric diseases, ageing, and radiation-induced brain damage. The relevant molecular mechanisms and its anti-neuroinflammatory, anti-apoptotic, anti-oxidant, as well as pro-neurogenesis roles were also discussed.
Collapse
Affiliation(s)
- Ling Rui Li
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Gautam Sethi
- Department of Pharmacology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117600, Singapore
| | - Xing Zhang
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Cui Liu Liu
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Yan Huang
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Qun Liu
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Bo Xu Ren
- The School of Basic Medicine, Health Science Center, Yangtze University, Jingzhou 434023, Hubei, China
| | - Feng Ru Tang
- Radiation Physiology Lab, Singapore Nuclear Research and Safety Initiative, National University of Singapore, Singapore 138602, Singapore
| |
Collapse
|
39
|
Daubner D, Piwarz L, Cerhova J, Wahl H, Linn J, Gerber J. Direct radiation exposure of the eye lenses in cranial computed tomography and exposure reduction through radiographer training. Radiography (Lond) 2022; 28:823-830. [DOI: 10.1016/j.radi.2022.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/14/2022] [Accepted: 01/18/2022] [Indexed: 10/19/2022]
|
40
|
Strigari L, Strolin S, Morganti AG, Bartoloni A. Dose-Effects Models for Space Radiobiology: An Overview on Dose-Effect Relationships. Front Public Health 2021; 9:733337. [PMID: 34820349 PMCID: PMC8606590 DOI: 10.3389/fpubh.2021.733337] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 09/27/2021] [Indexed: 12/20/2022] Open
Abstract
Space radiobiology is an interdisciplinary science that examines the biological effects of ionizing radiation on humans involved in aerospace missions. The dose-effect models are one of the relevant topics of space radiobiology. Their knowledge is crucial for optimizing radioprotection strategies (e.g., spaceship and lunar space station-shielding and lunar/Mars village design), the risk assessment of the health hazard related to human space exploration, and reducing damages induced to astronauts from galactic cosmic radiation. Dose-effect relationships describe the observed damages to normal tissues or cancer induction during and after space flights. They are developed for the various dose ranges and radiation qualities characterizing the actual and the forecast space missions [International Space Station (ISS) and solar system exploration]. Based on a Pubmed search including 53 papers reporting the collected dose-effect relationships after space missions or in ground simulations, 7 significant dose-effect relationships (e.g., eye flashes, cataract, central nervous systems, cardiovascular disease, cancer, chromosomal aberrations, and biomarkers) have been identified. For each considered effect, the absorbed dose thresholds and the uncertainties/limitations of the developed relationships are summarized and discussed. The current knowledge on this topic can benefit from further in vitro and in vivo radiobiological studies, an accurate characterization of the quality of space radiation, and the numerous experimental dose-effects data derived from the experience in the clinical use of ionizing radiation for diagnostic or treatments with doses similar to those foreseen for the future space missions. The growing number of pooled studies could improve the prediction ability of dose-effect relationships for space exposure and reduce their uncertainty level. Novel research in the field is of paramount importance to reduce damages to astronauts from cosmic radiation before Beyond Low Earth Orbit exploration in the next future. The study aims at providing an overview of the published dose-effect relationships and illustrates novel perspectives to inspire future research.
Collapse
Affiliation(s)
- Lidia Strigari
- Department of Medical Physics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Silvia Strolin
- Department of Medical Physics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Alessio Giuseppe Morganti
- Radiation Oncology Center, School of Medicine, Department of Experimental, Diagnostic and Specialty Medicine - DIMES, University of Bologna, Bologna, Italy
| | | |
Collapse
|
41
|
Rivera-López R, García-López C, Sánchez-Moreno JM, Rivera-López RA, Almansa-López J, Rivera-Fernández R, Molina-Navarro E, Jiménez-Fernández M, Ortiz-Pérez S, Ramírez-Hernández JA. High Incidence of Cataracts in the Follow-Up of Patients Undergoing Percutaneous Coronary Intervention for Chronic Coronary Total Occlusion. J Clin Med 2021; 10:jcm10215002. [PMID: 34768525 PMCID: PMC8584919 DOI: 10.3390/jcm10215002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/20/2021] [Accepted: 10/26/2021] [Indexed: 11/16/2022] Open
Abstract
Development of cataracts is a well-known adverse effect of ionizing radiation, but little information is available on their incidence in patients after other medical procedures, such as cardiac catheterizations. The study objective was to determine the incidence of cataracts in a cohort of patients undergoing percutaneous coronary intervention (PCI) for chronic coronary total occlusion (CTO) and its association with radiation dose. The study analyzed the incidence of cataracts during the follow-up of 126 patients who underwent chronic total coronary PCI, using Cox regression to identify predictive factors of cataract development. The study included 126 patients, 86.9% male, with a mean age of 60.5 years (range, 55.0-68.0 years). Twenty-three (18.2% n = 23) developed cataracts during a mean follow-up of 49.5 months (range 37.3-64.5 months). A higher incidence was observed in patients who received more than 5 Gy (29.0% vs. 14.7%, Hazard ratio (HR = 2.84 [1.19-6.77]). Multivariate analysis revealed a relationship between cataract development during the follow-up and a receipt of radiation dose >5 Gy (HR = 2.60, 95% confidence interval [CI 1.03-6.61]; p = 0.03), presence or history of predisposing eye disease (HR = 4.42, CI:1.57-12.40), diabetes (HR = 3.33 [1.22-9.24]), and older age, as in >57 (HR, 6.40 [1.81-22.61]). An elevated incidence of cataracts was observed in patients after PCI for CTO. The onset of cataracts is related to the radiation dose during catheterization, which is a potentially avoidable effect of which operators should be aware.
Collapse
Affiliation(s)
- Ricardo Rivera-López
- Cardiology Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain; (R.R.-L.); (J.M.S.-M.); (E.M.-N.); (M.J.-F.); (J.A.R.-H.)
- Biosanitary Research Institute ibs.GRANADA, 18012 Granada, Spain;
| | - Celia García-López
- Department of Ophtalmology, University Hospital Virgen de las Nieves, Av. de las Fuerzas Armadas, 2, 18014 Granada, Spain
- Correspondence: ; Tel.: +34-958020009
| | - José M. Sánchez-Moreno
- Cardiology Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain; (R.R.-L.); (J.M.S.-M.); (E.M.-N.); (M.J.-F.); (J.A.R.-H.)
| | | | - Julio Almansa-López
- Radiophysics Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain;
| | | | - Eduardo Molina-Navarro
- Cardiology Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain; (R.R.-L.); (J.M.S.-M.); (E.M.-N.); (M.J.-F.); (J.A.R.-H.)
| | - Miriam Jiménez-Fernández
- Cardiology Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain; (R.R.-L.); (J.M.S.-M.); (E.M.-N.); (M.J.-F.); (J.A.R.-H.)
| | - Santiago Ortiz-Pérez
- Biosanitary Research Institute ibs.GRANADA, 18012 Granada, Spain;
- Department of Ophtalmology, University Hospital Virgen de las Nieves, Av. de las Fuerzas Armadas, 2, 18014 Granada, Spain
- University of Granada (UGR), 18016 Granada, Spain;
| | - José A. Ramírez-Hernández
- Cardiology Department, Virgen de las Nieves University Hospital, 18014 Granada, Spain; (R.R.-L.); (J.M.S.-M.); (E.M.-N.); (M.J.-F.); (J.A.R.-H.)
- Biosanitary Research Institute ibs.GRANADA, 18012 Granada, Spain;
- Medicine Department, University of Granada (UGR), 18016 Granada, Spain
| |
Collapse
|
42
|
Belotta AF, Mayer MN, Koehncke NK, Carmalt J, Freitas FP, Waldner CL. Survey of self-reported radiation safety practices among North American veterinary technicians involved in equine radiography using portable x-ray equipment. J Am Vet Med Assoc 2021; 259:919-926. [PMID: 34609178 DOI: 10.2460/javma.259.8.919] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVES To describe self-reported radiation safety practices by equine veterinary technicians in North America and identify factors associated with these practices. SAMPLE 154 equine technicians. PROCEDURES An electronic questionnaire regarding radiation safety practices during the use of portable x-ray equipment was sent to 884 members of the American Association of Equine Veterinary Technicians and Assistants. Data were summarized, and various factors were evaluated for associations with reported safety practices. RESULTS 221 of 884 (25.0%) questionnaires were completed, including 154 by equine technicians who had been involved in equine radiography as x-ray tube operators, cassette holders, or both in the previous year. Lead apron use was suboptimal, reported as "always" for 80.0% (104/130) of tube operators and 83.1% (123/148) of cassette holders. Approximately 20% of participants never wore thyroid shields, and approximately 90% never wore lead eyeglasses. Almost 50% of participants did not have lead eyeglasses available. Although > 55% of participants always held the x-ray equipment by hand, 58.4% (73/125) of tube operators and 25.0% (35/140) of cassette holders never wore gloves. Cassette holders wore lead gloves and personal radiation dose-monitoring devices significantly more frequently than did tube operators. CONCLUSIONS AND CLINICAL RELEVANCE Compliance of North American equine technicians with radiation safety recommendations by the National Council on Radiation Protection and Measurements was suboptimal. Improvements in radiation safety training and education, strengthening the connection between academic institutions and private practices, and greater availability and requirement of personal protective equipment use by senior clinicians and employers might aid in improving safety practices.
Collapse
|
43
|
Abstract
Data suggest that radiation-induced cataracts may form without a threshold and at low-radiation doses. Staff involved in interventional radiology and cardiology fluoroscopy-guided procedures have the potential to be exposed to radiation levels that may lead to eye lens injury and the occurrence of opacifications have been reported. Estimates of lens dose for various fluoroscopy procedures and predicted annual dosages have been provided in numerous publications. Available tools for eye lens radiation protection include accessory shields, drapes and glasses. While some tools are valuable, others provide limited protection to the eye. Reducing patient radiation dose will also reduce occupational exposure. Significant variability in reported dose measurements indicate dose levels are highly dependent on individual actions and exposure reduction is possible. Further follow-up studies of staff lens opacification are recommended along with eye lens dose measurements under current clinical practice conditions.
Collapse
Affiliation(s)
| | - Kenneth A Fetterly
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
44
|
Iori M, Isolan L, Piergallini L, Chendi A, Lasagni L, Cucchi G, Bertolini M, Fioroni F, Piccagli V, Moramarco A, Romano MG, Fontana L, Strigari L, D'Alessio D, Bruzzaniti V, Sgura A, Udroiu I, Rosi A, Grande S, Palma A, Giliberti C, Sumini M. How direct measurements of worker eyes with a Scheimpflug camera can affect lensdose coefficients in interventional radiology. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:689-706. [PMID: 33827064 DOI: 10.1088/1361-6498/abf56f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Accepted: 04/07/2021] [Indexed: 06/12/2023]
Abstract
The 2013/59/Euratom Directive reduced the occupational exposure limits for the lens. Since it has become crucial to estimate the dose absorbed by the lens, we have studied the individual variability of exposed workers' ocular conformations with respect to the data estimated from their personal dosimetry. The anterior eye conformations of 45 exposed workers were acquired using Scheimpflug imaging and classified according to their sight conditions (emmetropia, myopia or hypermetropia). Three eye models were computed, with two lens reconstructions, and implemented in an interventional radiology scenario using Monte Carlo code. The models were dosimetrically analysed by simulating setup A, a theoretical monoenergetic and isotropic photon source (10-150 keV) and setup B, a more realistic interventional setting with an angiographic x-ray unit (50, 75, 100 kV peak). Scheimpflug imaging provided an average anterior chamber depth of (6.4 ± 0.5) mm and a lens depth of (3.9 ± 0.3) mm, together with a reconstructed equatorial lens length of (7.1-10.1) mm. Using these data for model reconstruction, dose coefficients (DCs) were simulated for all ocular structures. Regardless of the eye model used, the DCs showed a similar trend with radiation energy, which highlighted that for the same energy and setup, no significant dependence on ocular morphology and workers' visual conditions was observed. The maximum difference obtained did not exceed 1% for all eye models or structures analysed. Therefore, the individual variabilities of worker ocular anatomy do not require any additional correction, compared to the personal dosimetry data measured with a dedicated lens dosimeter. To estimate the dose absorbed by the other eye structures, it is, instead, essential to know the spectrum of the source that has generated the irradiation, since there are differences between monoenergetic sources and more realistic angiographic units.
Collapse
Affiliation(s)
- Mauro Iori
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Lorenzo Isolan
- University of Bologna, Industrial Engineering Department, Montecuccolino Laboratory, Bologna, Italy
- Interdepartmental Center 'L. Galvani' CIG, Alma Mater Studiorum Università di Bologna, Bologna, Italy
- INFN, Bologna, Italy
| | - Lorenzo Piergallini
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Agnese Chendi
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
- Medical Physics, University of Bologna, Bologna, Italy
| | - Lorenzo Lasagni
- Postgraduate school in Medical Physics, University of Firenze, Firenze, Italy
| | - Giorgio Cucchi
- University of Bologna, Industrial Engineering Department, Montecuccolino Laboratory, Bologna, Italy
- Interdepartmental Center 'L. Galvani' CIG, Alma Mater Studiorum Università di Bologna, Bologna, Italy
| | - Marco Bertolini
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Federica Fioroni
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Vando Piccagli
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Antonio Moramarco
- Ophthalmology Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Maria Grazia Romano
- Ophthalmology Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Luigi Fontana
- Ophthalmology Unit, Azienda USL-IRCCS di Reggio Emilia, Reggio Emilia, Italy
| | - Lidia Strigari
- Department of Medical Physics, St. Orsola-Malpighi University Hospital, Bologna, Italy
| | - Daniela D'Alessio
- Laboratory of Medical Physics and Expert Systems, Regina Elena Cancer Institute IRCCS, Rome, Italy
| | - Vicente Bruzzaniti
- Laboratory of Medical Physics and Expert Systems, Regina Elena Cancer Institute IRCCS, Rome, Italy
| | - Antonella Sgura
- Department of Science, University of Rome 'Roma Tre', Rome, Italy
| | - Ion Udroiu
- Department of Science, University of Rome 'Roma Tre', Rome, Italy
| | - Antonella Rosi
- Istituto Superiore di Sanità, Centro Nazionale Tecnologie Innovative in Sanità Pubblica, Rome, Italy
| | - Sveva Grande
- Istituto Superiore di Sanità, Centro Nazionale Tecnologie Innovative in Sanità Pubblica, Rome, Italy
| | - Alessandra Palma
- Istituto Superiore di Sanità, Centro Nazionale Tecnologie Innovative in Sanità Pubblica, Rome, Italy
| | - Claudia Giliberti
- Inail-Dipartimento Innovazioni Tecnologiche e Sicurezza degli Impianti, Prodotti ed Insediamenti Antropici, Rome, Italy
| | - Marco Sumini
- University of Bologna, Industrial Engineering Department, Montecuccolino Laboratory, Bologna, Italy
- Interdepartmental Center 'L. Galvani' CIG, Alma Mater Studiorum Università di Bologna, Bologna, Italy
- INFN, Bologna, Italy
| |
Collapse
|
45
|
Out-of-field organ doses and associated risk of cancer development following radiation therapy with photons. Phys Med 2021; 90:73-82. [PMID: 34563834 DOI: 10.1016/j.ejmp.2021.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/06/2021] [Accepted: 09/13/2021] [Indexed: 11/21/2022] Open
Abstract
Innovations in cancer treatment have contributed to the improved survival rate of these patients. Radiotherapy is one of the main options for cancer management nowadays. High doses of ionizing radiation are usually delivered to the tumor site with high energy photon beams. However, the therapeutic radiation exposure may lead to second cancer induction. Moreover, the introduction of intensity-modulated radiation therapy over the last decades has increased the radiation dose to out-of-field organs compared to that from conventional irradiation. The increased organ doses might result in elevated probabilities for developing secondary malignancies to critical organs outside the treatment volume. The organ-specific dosimetry is considered necessary for the theoretical second cancer risk assessment and the proper analysis of data derived from epidemiological reports. This study reviews the methods employed for the measurement and calculation of out-of-field organ doses from exposure to photons and/or neutrons. The strengths and weaknesses of these dosimetric approaches are described in detail. This is followed by a review of the epidemiological data associated with out-of-field cancer risks. Previously published theoretical cancer risk estimates for adult and pediatric patients undergoing radiotherapy with conventional and advanced techniques are presented. The methodology for the theoretical prediction of the probability of carcinogenesis to out-of-field sites and the limitations of this approach are discussed. The article also focuses on the factors affecting the magnitude of the probability for developing radiotherapy-induced malignancies. The restriction of out-of-field doses and risks through the use of different types of shielding equipment is presented.
Collapse
|
46
|
Li Y, Parkinson DY, Feng J, Xia CH, Gong X. Quantitative X-ray tomographic analysis reveals calcium precipitation in cataractogenesis. Sci Rep 2021; 11:17401. [PMID: 34465795 PMCID: PMC8408149 DOI: 10.1038/s41598-021-96867-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 08/12/2021] [Indexed: 02/07/2023] Open
Abstract
Cataracts, named for pathological light scattering in the lens, are known to be associated with increased large protein aggregates, disrupted protein phase separation, and/or osmotic imbalances in lens cells. We have applied synchrotron phase contrast X-ray micro-computed tomography to directly examine an age-related nuclear cataract model in Cx46 knockout (Cx46KO) mice. High-resolution 3D X-ray tomographic images reveal amorphous spots and strip-like dense matter precipitates in lens cores of all examined Cx46KO mice at different ages. The precipitates are predominantly accumulated in the anterior suture regions of lens cores, and they become longer and dense as mice age. Alizarin red staining data confirms the presence of calcium precipitates in lens cores of all Cx46KO mice. This study indicates that the spatial and temporal calcium precipitation is an age-related event associated with age-related nuclear cataract formation in Cx46KO mice, and further suggests that the loss of Cx46 promotes calcium precipitates in the lens core, which is a new mechanism that likely contributes to the pathological light scattering in this age-related cataract model.
Collapse
Affiliation(s)
- Yuxing Li
- Vision Science Program and School of Optometry, University of California, Berkeley, 693 Minor Hall, Berkeley, CA, 94720-2020, USA
- Tsinghua-Berkeley Shenzhen Institute (TBSI), UC Berkeley, Berkeley, CA, USA
| | - Dilworth Y Parkinson
- Advanced Light Source Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Jun Feng
- Advanced Light Source Division, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Chun-Hong Xia
- Vision Science Program and School of Optometry, University of California, Berkeley, 693 Minor Hall, Berkeley, CA, 94720-2020, USA
| | - Xiaohua Gong
- Vision Science Program and School of Optometry, University of California, Berkeley, 693 Minor Hall, Berkeley, CA, 94720-2020, USA.
| |
Collapse
|
47
|
Tinganelli W, Luoni F, Durante M. What can space radiation protection learn from radiation oncology? LIFE SCIENCES IN SPACE RESEARCH 2021; 30:82-95. [PMID: 34281668 DOI: 10.1016/j.lssr.2021.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/15/2021] [Accepted: 06/17/2021] [Indexed: 06/13/2023]
Abstract
Protection from cosmic radiation of crews of long-term space missions is now becoming an urgent requirement to allow a safe colonization of the moon and Mars. Epidemiology provides little help to quantify the risk, because the astronaut group is small and as yet mostly involved in low-Earth orbit mission, whilst the usual cohorts used for radiation protection on Earth (e.g. atomic bomb survivors) were exposed to a radiation quality substantially different from the energetic charged particle field found in space. However, there are over 260,000 patients treated with accelerated protons or heavier ions for different types of cancer, and this cohort may be useful for quantifying the effects of space-like radiation in humans. Space radiation protection and particle therapy research also share the same tools and devices, such as accelerators and detectors, as well as several research topics, from nuclear fragmentation cross sections to the radiobiology of densely ionizing radiation. The transfer of the information from the cancer radiotherapy field to space is manifestly complicated, yet the two field should strengthen their relationship and exchange methods and data.
Collapse
Affiliation(s)
- Walter Tinganelli
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Darmstadt, Germany
| | - Francesca Luoni
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Darmstadt, Germany; Technische Universität Darmstadt, Institut für Physik Kondensierter Materie, Darmstadt, Germany
| | - Marco Durante
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Darmstadt, Germany; Technische Universität Darmstadt, Institut für Physik Kondensierter Materie, Darmstadt, Germany.
| |
Collapse
|
48
|
Ahmadi M, Barnard S, Ainsbury E, Kadhim M. Early Responses to Low-Dose Ionizing Radiation in Cellular Lens Epithelial Models. Radiat Res 2021; 197:78-91. [PMID: 34324666 DOI: 10.1667/rade-20-00284.1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Accepted: 07/06/2021] [Indexed: 11/03/2022]
Abstract
Cataract is the leading cause of visual impairment which can result in blindness. Cataract formation has been associated with radiation exposure; however, the mechanistic understanding of this phenomenon is still lacking. The goal of this study was to investigate mechanisms of cataract induction in isolated lens epithelial cells (LEC) exposed to ionizing radiation. Human LECs from different genetic backgrounds (SV40 immortalized HLE-B3 and primary HLEC cells) were exposed to varying doses of 137Cs gamma rays (0, 0.1, 0.25 and 0.5 Gy), at low (0.065 Gy/min) and higher (0.3 Gy/min) dose rates. Different assays were used to measure LEC response for, e.g., viability, oxidative stress, DNA damage studies, senescence and changes to telomere length/telomerase activity at two time points (1 h and 24 h, or 24 h and 15 days, depending on the type of assay and expected response time). The viability of cells decreased in a dose-dependent manner within 24 h of irradiation. Measurement of reactive oxygen species showed an increase at 1 h postirradiation, which was alleviated within 24 h. This was consistent with DNA damage results showing high DNA damage after 1 h postirradiation which reduced significantly (but not completely) within 24 h. Induction of senescence was also observed 15 days postirradiation, but this was not attributed to telomere erosion or telomerase activity reduction. Overall, these findings provide a mechanistic understanding of low-dose radiation-induced cataractogenesis which will ultimately help to inform judgements on the magnitude of risk and improve existing radiation protection procedures.
Collapse
Affiliation(s)
- Maryam Ahmadi
- Genomic Instability and Cell Communication Research Group, Department of Biological and Medical Science, Oxford Brookes University, Oxford, United Kingdom.,Kidney Genetics Group, Academic Unit of Nephrology, The Medical School, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | - Stephen Barnard
- Public Health England, Centre for Radiation, Chemical and Environmental Hazards, Oxford, United Kingdom
| | - Elizabeth Ainsbury
- Public Health England, Centre for Radiation, Chemical and Environmental Hazards, Oxford, United Kingdom
| | - Munira Kadhim
- Genomic Instability and Cell Communication Research Group, Department of Biological and Medical Science, Oxford Brookes University, Oxford, United Kingdom
| |
Collapse
|
49
|
Under-recognized toxicities of cranial irradiation. Cancer Radiother 2021; 25:713-722. [PMID: 34274224 DOI: 10.1016/j.canrad.2021.06.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 06/21/2021] [Accepted: 06/24/2021] [Indexed: 11/23/2022]
Abstract
Cranial irradiation of primary or metastatic lesions is frequent, historically with 3D-conformal radiation therapy and now with stereotactic radiosurgery and intensity modulation. Evolution of radiotherapy technique is concomitant to systemic treatment evolution permitting long time survival. Thus, physicians have to face underestimated toxicities on long-survivor patients and unknown toxicities from combination of cranial radiotherapy to new therapeutics as targeted therapies and immunotherapies. This article proposes to develop these toxicities, without being exhaustive, to allow a better apprehension of cranial irradiation in current context.
Collapse
|
50
|
Haynes A, Nathan A, Maitland C, Dixon H, Nicholson A, Wakefield M, Dobbinson S. Prevalence and Correlates of Observed Sun Protection Behaviors Across Different Public Outdoor Settings in Melbourne, Australia. HEALTH EDUCATION & BEHAVIOR 2021; 49:405-414. [PMID: 34238043 DOI: 10.1177/10901981211026535] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Skin cancer prevention efforts in Australia have increasingly incorporated a focus on protection during incidental sun exposure. This complements the long-present messages promoting protection in high-risk settings and avoidance of acute intense bouts of sun exposure. Data from two waves of a cross-sectional direct observational survey was used to assess the prevalence and correlates of N = 12,083 adolescents' and adults' sun protection behavior (arm and leg cover, hat, sunglasses, and shade cover). Individuals were observed in public outdoor settings in Melbourne, Australia during peak ultraviolet (UV) times (11 a.m.-3 p.m.) on summer weekends. Settings included pools and beaches, parks and gardens, and for the first time in 2018, outdoor streets and cafés which may capture more incidental forms of sun exposure and represent another public setting where Australians commonly spend time outdoors. Females and older adults were consistently better protected than males and adolescents. Physical activity was strongly associated with low shade cover across settings. Weather was more strongly associated with sun protection at outdoor streets/cafes and parks/gardens than at pools/beaches but use of observed sun protection (particularly arm cover and covering hat) was low across settings. Continued public education about UV risk and its relation to weather and the seasons is needed to promote the routine use of multiple forms of sun protection during outdoor activities in peak UV times, especially among males and adolescents. Findings also highlight the importance of considering activity demands of public spaces in shade planning to optimize sun protection during outdoor activities in public spaces.
Collapse
Affiliation(s)
- Ashleigh Haynes
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia
| | - Andrea Nathan
- Telethon Kids Institute, Perth Children's Hospital, Nedlands, WA, Australia
| | - Clover Maitland
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia
| | - Helen Dixon
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia.,Melbourne School of Psychological Sciences, The University of Melbourne, Parkville, VIC, Australia
| | - Anna Nicholson
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia
| | - Melanie Wakefield
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia.,Melbourne School of Psychological Sciences, The University of Melbourne, Parkville, VIC, Australia
| | - Suzanne Dobbinson
- Centre for Behavioural Research in Cancer, Cancer Council Victoria, Melbourne, VIC, Australia
| |
Collapse
|