Pham HN, Pham PNH, Phan HT, Cao LT, Thoi HTT, Do TDT, Truong TTA. Impact of hematocrit levels on the accuracy of specific blood glucose meters: A hospital-based study. J Diabetes Investig 2024. [PMID: 39087885 DOI: 10.1111/jdi.14276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 07/10/2024] [Accepted: 07/17/2024] [Indexed: 08/02/2024] Open
Abstract
AIMS/INTRODUCTION Blood glucose meters are commonly used at the bedside, but most of the meters used in Hung Vuong Hospital (Ho Chi Minh City, Vietnam) are built for self-monitoring and might not be suitable for determining glucose levels in patients. In this study, we aimed to validate the performance of six frequently used meters in our hospital using the Clinical & Laboratory Standards Institute (CLSI) standard, and investigate the hematocrit impact on the accuracy of these meters. MATERIALS AND METHODS A total of 135 pregnant women who underwent a 75-g oral glucose tolerance test consented to participate in the study at Hung Vuong Hospital. Whole blood glucose levels were measured in duplicate using meters, and hematocrit levels were measured using an Alinity h-series analyzer. Within 5 min, plasma glucose levels were measured twice in a row using the Cobas c502 reference analyzer. For accuracy and precision, the hematocrit effect was assed using CLSI POCT12-A3. RESULTS Out of six evaluated meters, three meters qualified. For CLSI criterion at glucose concentration of 5.55 mmol/L, Accu-Chek Inform II, Accu-Chek Performa and OneTouch VerioVue achieved 97.31%, 98.08% and 99.62%, respectively. For CLSI criterion at 4.17 mmol/L, these three achieved 100%. Accu-Chek Inform II and Accu-Chek Performa showed an inverse correlation between glucose level and hematocrit with slopes of -0.500 (95% confidence interval -0.678 to -0.322) and -0.396 (95% confidence interval -0.569 to -0.224), whereas OneTouch VerioVue was not affected by hematocrit, with a slope of 0.207 (95% confidence interval -0.026 to 0.440). CONCLUSIONS Blood glucose meters' measurements can be affected by hematocrit, and might provide readings not within an acceptable bias. Medical organizations need to verify or validate before using on patients.
Collapse
|
2
|
Pleus S, Baumstark A, Schauer S, Kölle J, Jendrike N, Mende J, Haug C, Freckmann G. User Performance Evaluation and System Accuracy Assessment of Four Blood Glucose Monitoring Systems With Color Coding of Measurement Results. J Diabetes Sci Technol 2024; 18:644-652. [PMID: 36433806 PMCID: PMC11089863 DOI: 10.1177/19322968221141926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Blood glucose monitoring systems (BGMSs) are a cornerstone in diabetes management. They have to provide sufficiently accurate results in the hands of lay users, particularly in insulin-treated patients. The aim of this study was user performance evaluation and system accuracy assessment of four BGMSs with color coding of results. METHODS Study procedures were based on ISO 15197:2013. User performance evaluation included data from 100 participants, each of whom used every system with one reagent lot. Study personnel observed user techniques. For the system accuracy assessment, 100 capillary samples were obtained for measurement in duplicate with each of three reagent system lots per system, resulting in 600 results per system. RESULTS All assessed BGMSs exhibited a sufficient level of accuracy, with small differences between them. In the user performance evaluation, study personnel observed the smallest total number of user errors with Contour Next (Ascensia), followed by Accu-Chek Instant (Roche), Medisafe Fit Smile (Terumo), and OneTouch Ultra Plus Reflect (LifeScan). Approximately 90% of participants stated that a consistent color scheme, eg, for low blood glucose (BG) values, should be used across all BGMSs. There was no clear preference among the four tested BGMSs regarding the specific way of displaying color coding. CONCLUSIONS The four BGMSs assessed in this study showed only small differences in an overall sufficient level of accuracy. User handling errors, as observed by study personnel, differed between the systems.
Collapse
Affiliation(s)
- Stefan Pleus
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Annette Baumstark
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Sebastian Schauer
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Julia Kölle
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Nina Jendrike
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Jochen Mende
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Cornelia Haug
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| |
Collapse
|
3
|
Dyess RJ, McKay T, Feygin Y, Wintergerst K, Thrasher BJ. Factory-Calibrated Continuous Glucose Monitoring System Accuracy During Exercise in Adolescents With Type 1 Diabetes Mellitus. J Diabetes Sci Technol 2024; 18:584-591. [PMID: 36047647 PMCID: PMC11089875 DOI: 10.1177/19322968221120433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Continuous glucose monitors (CGMs) are widely used for individuals with diabetes mellitus, particularly those with type 1 diabetes (T1D). Advancements in CGM technology allow for glycemic assessment without capillary glucose measurements as many come factory calibrated. However, exercise, an essential component of diabetes care, has been reported to alter accuracy of earlier generation CGM. Considering the importance of physical activity for individuals with T1D and the progression of CGM technology, we aimed to investigate the accuracy of the Dexcom G6 during physical activity. METHODS Adolescents (ages 13-20 years) exercised on a treadmill for 40 minutes, with a 10-minute break at minute 20. We obtained paired CGM and glucometer measurements before and every 10 minutes during and after exercise. Accuracy analysis was determined by mean absolute relative difference (MARD), mean absolute difference (MAD), and Clarke Error Grid Analyses. RESULTS Mean absolute relative difference and MAD increased during exercise (14%-33% and 24.3-34 mg/dL) but improved after exercise. We noted certain CGM locations produced greater changes in accuracy as MARD and MAD increased markedly when the CGM was on the buttocks (18%-46% and 30-41 mg/dL). We also noted decreased odds of Zone A in the Clarke error grid when the CGM was on the buttocks compared to the abdomen (odds ratio [OR]: 0.146; P = 0.0003; 95% CI = 0.052-0.415). CONCLUSIONS This CGM system showed alterations in accuracy during exercise. Our findings additionally suggest interstitial fluid changes in muscles during exercise alter accuracy of CGM; however, additional research is required.
Collapse
Affiliation(s)
- Ryan J. Dyess
- Division of Pediatric Endocrinology, Department of Pediatrics, University of Louisville School of Medicine, Louisville, KY, USA
- Wendy Novak Diabetes Center and University of Louisville School of Medicine, Louisville, KY, USA
- Norton Children’s Medical Group and University of Louisville School of Medicine, Louisville, KY, USA
| | - Timothy McKay
- Wendy Novak Diabetes Center and University of Louisville School of Medicine, Louisville, KY, USA
- Norton Children’s Research Institute and University of Louisville School of Medicine, Louisville, KY, USA
| | - Yana Feygin
- Norton Children’s Research Institute and University of Louisville School of Medicine, Louisville, KY, USA
| | - Kupper Wintergerst
- Division of Pediatric Endocrinology, Department of Pediatrics, University of Louisville School of Medicine, Louisville, KY, USA
- Wendy Novak Diabetes Center and University of Louisville School of Medicine, Louisville, KY, USA
- Norton Children’s Medical Group and University of Louisville School of Medicine, Louisville, KY, USA
| | - Bradly J. Thrasher
- Division of Pediatric Endocrinology, Department of Pediatrics, University of Louisville School of Medicine, Louisville, KY, USA
- Wendy Novak Diabetes Center and University of Louisville School of Medicine, Louisville, KY, USA
- Norton Children’s Medical Group and University of Louisville School of Medicine, Louisville, KY, USA
| |
Collapse
|
4
|
Villa-Tamayo MF, Builes-Montaño CE, Ramirez-Rincón A, Carvajal J, Rivadeneira PS. Accuracy of an Off-Label Transmitter and Data Manager Paired With an Intermittent Scanned Continuous Glucose Monitor in Adults With Type 1 Diabetes. J Diabetes Sci Technol 2024; 18:701-708. [PMID: 36281579 PMCID: PMC11089852 DOI: 10.1177/19322968221133405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND This work evaluates the accuracy and agreement between the FreeStyle Libre sensor (FSL) and an off-label converted real-time continuous glucose monitor (c-rtCGM) device consisting of the MiaoMiao transmitter and the xDrip+ application which can be coupled to the FSL. METHODS Four weeks of glucose data were collected from 21 participants with type 1 diabetes using the c-rtCGM and FSL: two weeks with a single initial calibration (uncalibrated) and two weeks with a daily calibration (calibrated). Accuracy and agreement evaluation included mean absolute relative difference (MARD), the %20/20 rule, Bland-Altman plots, and the Consensus Error Grid analysis. RESULTS Values reported by the c-rtCGM system compared with the FSL resulted in an overall MARD of 12.06% and 84.71% of the results falling within Consensus Error Grid Zone A when the device is calibrated. For uncalibrated devices, an overall MARD of 17.49% was obtained. Decreased accuracy was shown in the hypoglycemic range and for rates of change greater than 2 mg/dL/min. The between-device bias also incremented with increasing glucose values. CONCLUSION Measurements recorded by the c-rtCGM were found to be accurate when compared with FSL data only when performing daily c-rtCGM device calibrations. High drops in accuracy and agreement between devices occurred when the c-rtCGM was not calibrated.
Collapse
Affiliation(s)
- María F. Villa-Tamayo
- Department of Engineering Systems and Environment, University of Virginia, Charlottesville, VA, USA
| | | | - Alex Ramirez-Rincón
- Facultad de Medicina, Universidad Pontificia Bolivariana, Medellin, Colombia
- Clínica Integral de Diabetes, Medellín, Colombia
| | | | - Pablo S. Rivadeneira
- Grupo GITA, Facultad de Minas, Universidad Nacional de Colombia, Medellín, Colombia
| |
Collapse
|
5
|
Luppa PB, Zeller M, Pieper M, Kaiser P, Weiss N, Vierbaum L, Freckmann G. Quality assessment of glucose measurement with regard to epidemiology and clinical management of diabetes mellitus in Germany. Front Mol Biosci 2024; 11:1371426. [PMID: 38572446 PMCID: PMC10987728 DOI: 10.3389/fmolb.2024.1371426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 03/05/2024] [Indexed: 04/05/2024] Open
Abstract
Background During the last decade, Germany has seen an increased prevalence and a redistribution from undetected to diagnosed diabetes mellitus. Due to this substantial epidemiological development, the number of people with documented type 2 diabetes was 8.7 million in 2022. An estimated two million undiagnosed subjects are to be added. Beyond that, the life expectancy of diabetic subjects is increasing due to more responsive health systems in terms of care. Possible reasons include improved screening of at-risk individuals, the introduction of HbA1c for diagnosis in 2010, and the higher use of risk scores. Additionally, quality aspects of the laboratory methodology should be taken into consideration. Methods Epidemiology and clinical management of diabetes in Germany are presented in the light of publications retrieved by a selective search of the PubMed database. Additionally, the data from German external quality assessment (EQA) surveys for the measurands glucose in plasma and HbA1c in whole blood, reviewed from 2010 until 2022, were evaluated. Above this, data concerning the analytical performance of near-patient glucometer devices, according to the ISO norm 15197:2013, were analyzed. Results Two laboratory aspects are in good accordance with the observation of an increase in the diabetes mellitus prevalence when retrospectively reviewing the period 2010 to 2022: First, the analytical performance according to the ISO norm 15197:2013 of the glucometer devices widely used by patients with diabetes for the glucose self-testing, has improved during this period. Secondly, concerning the EQA program of INSTAND, the number of participating laboratories raised significantly in Germany. The spreads of variations of the specified results for plasma glucose remained unchanged between 2010 and 2022, whereas for HbA1c a significant decrease of the result scattering could be observed. Conclusion These retrospectively established findings testify to an excellent analytical quality of laboratory diagnostics for glucose and HbA1c throughout Germany which may be involved in a better diagnosis and therapy of previously undetected diabetes mellitus.
Collapse
Affiliation(s)
- Peter B. Luppa
- Institut für Klinische Chemie und Pathobiochemie, Klinikum rechts der Isar der Technische Universität München, Munich, Germany
| | - Michael Zeller
- Institut für Klinische Chemie und Pathobiochemie, Klinikum rechts der Isar der Technische Universität München, Munich, Germany
| | - Marija Pieper
- Institut für Klinische Chemie und Pathobiochemie, Klinikum rechts der Isar der Technische Universität München, Munich, Germany
| | - Patricia Kaiser
- INSTAND e.V., Gesellschaft zur Förderung der Qualitätssicherung in Medizinischen Laboratorien e.V., Düsseldorf, Germany
| | - Nathalie Weiss
- INSTAND e.V., Gesellschaft zur Förderung der Qualitätssicherung in Medizinischen Laboratorien e.V., Düsseldorf, Germany
| | - Laura Vierbaum
- INSTAND e.V., Gesellschaft zur Förderung der Qualitätssicherung in Medizinischen Laboratorien e.V., Düsseldorf, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| |
Collapse
|
6
|
Pleus S, Jendrike N, Baumstark A, Mende J, Wehrstedt S, Haug C, Freckmann G. Evaluation of System Accuracy, Precision, Hematocrit Influence, and User Performance of Two Blood Glucose Monitoring Systems Based on ISO 15197:2013/EN ISO 15197:2015. Diabetes Ther 2024; 15:447-459. [PMID: 38100029 PMCID: PMC10838869 DOI: 10.1007/s13300-023-01517-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 11/29/2023] [Indexed: 02/06/2024] Open
Abstract
INTRODUCTION Sufficiently high analytical quality of blood glucose monitoring systems (BGMS) is a prerequisite for efficient diabetes therapy. In this study we assessed system accuracy, measurement repeatability, intermediate measurement precision, user performance, and the influence of hematocrit on two CE-marked blood glucose monitoring systems. For one BGMS, measurement accuracy using venous samples was additionally investigated. METHODS Study procedures were based on the International Organization of Standardization (ISO) 15197:2013/EN ISO 15197:2015 ("ISO 15197"). User performance included data from 100 subjects who used one test strip lot, whereas for all other analyses three different reagent system lots were used. For system accuracy assessment, 100 capillary samples were measured in duplicate with each of three reagent system lots per system, resulting in 600 results per system. RESULTS CareSens S Fit and CareSens H Beat both fulfilled the ISO 15197 accuracy criteria with 97.5-100% of each test strip lot's results falling within ± 15 mg/dL or ± 15% of the results of the comparison method and 100% of results in consensus error grid (CEG) zone A for all three lots. User performance evaluation revealed sufficient accuracy in the hands of lay users although some handling errors were documented by study staff. Assessment of measurement repeatability and intermediate measurement precision is given by standard deviation (SD) (glucose levels < 100 mg/dL) and by coefficient of variation (CV) (glucose concentrations ≥ 100 mg/dL). SD was ≤ 4.1 mg/dL and CV ≤ 4.2% for measurement repeatability and SD was ≤ 2.2 mg/dL and CV ≤ 2.6% for intermediate measurement precision. In case of hematocrit influence, both BGMS complied with all three tested lots with the defined criteria. CONCLUSION Both BGMS analyzed in this study fulfilled the required accuracy criteria of ISO 15197. They showed high precision, good performance in the hands of lay users, and the influence of hematocrit was acceptable in the labeled range.
Collapse
Affiliation(s)
- Stefan Pleus
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| | - Nina Jendrike
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| | - Annette Baumstark
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| | - Jochen Mende
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| | - Stephanie Wehrstedt
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany.
| | - Cornelia Haug
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Strasse 8/2, 89081, Ulm, Germany
| |
Collapse
|
7
|
Subramanian S, Khan F, Hirsch IB. New advances in type 1 diabetes. BMJ 2024; 384:e075681. [PMID: 38278529 DOI: 10.1136/bmj-2023-075681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2024]
Abstract
Type 1 diabetes is an autoimmune condition resulting in insulin deficiency and eventual loss of pancreatic β cell function requiring lifelong insulin therapy. Since the discovery of insulin more than 100 years ago, vast advances in treatments have improved care for many people with type 1 diabetes. Ongoing research on the genetics and immunology of type 1 diabetes and on interventions to modify disease course and preserve β cell function have expanded our broad understanding of this condition. Biomarkers of type 1 diabetes are detectable months to years before development of overt disease, and three stages of diabetes are now recognized. The advent of continuous glucose monitoring and the newer automated insulin delivery systems have changed the landscape of type 1 diabetes management and are associated with improved glycated hemoglobin and decreased hypoglycemia. Adjunctive therapies such as sodium glucose cotransporter-1 inhibitors and glucagon-like peptide 1 receptor agonists may find use in management in the future. Despite these rapid advances in the field, people living in under-resourced parts of the world struggle to obtain necessities such as insulin, syringes, and blood glucose monitoring essential for managing this condition. This review covers recent developments in diagnosis and treatment and future directions in the broad field of type 1 diabetes.
Collapse
Affiliation(s)
- Savitha Subramanian
- University of Washington Diabetes Institute, Division of Metabolism, Endocrinology and Nutrition, University of Washington, Seattle, WA, USA
| | - Farah Khan
- University of Washington Diabetes Institute, Division of Metabolism, Endocrinology and Nutrition, University of Washington, Seattle, WA, USA
| | - Irl B Hirsch
- University of Washington Diabetes Institute, Division of Metabolism, Endocrinology and Nutrition, University of Washington, Seattle, WA, USA
| |
Collapse
|
8
|
ElSayed NA, Aleppo G, Bannuru RR, Bruemmer D, Collins BS, Ekhlaspour L, Hilliard ME, Johnson EL, Khunti K, Lingvay I, Matfin G, McCoy RG, Perry ML, Pilla SJ, Polsky S, Prahalad P, Pratley RE, Segal AR, Seley JJ, Stanton RC, Gabbay RA. 7. Diabetes Technology: Standards of Care in Diabetes-2024. Diabetes Care 2024; 47:S126-S144. [PMID: 38078575 PMCID: PMC10725813 DOI: 10.2337/dc24-s007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, an interprofessional expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
9
|
Spanakis EK, Cook CB, Kulasa K, Aloi JA, Bally L, Davis G, Dungan KM, Galindo RJ, Mendez CE, Pasquel FJ, Shah VN, Umpierrez GE, Aaron RE, Tian T, Yeung AM, Huang J, Klonoff DC. A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials. J Diabetes Sci Technol 2023; 17:1527-1552. [PMID: 37592726 PMCID: PMC10658683 DOI: 10.1177/19322968231191104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/19/2023]
Abstract
Diabetes Technology Society organized an expert consensus panel to develop metrics for research in the use of continuous glucose monitors (CGMs) in a hospital setting. The experts met virtually in small groups both before and after an April 13, 2023 virtual meeting of the entire panel. The goal of the panel was to develop consensus definitions in anticipation of greater use of CGMs in hospital settings in the future. Establishment of consensus definitions of inpatient analytical metrics will be easier to compare outcomes between studies. Panelists defined terms related to 10 dimensions of measurements related to the use of CGMs including (1) hospital hypoglycemia, (2) hospital hyperglycemia, (3) hospital time in range, (4) hospital glycemic variability, (5) hospital glycemia risk index, (6) accuracy of CGM devices and reference methods for CGMs in the hospital, (7) meaningful time blocks for hospital glycemic goals, (8) hospital CGM data sufficiency, (9) using CGM data for insulin dosing, and (10) miscellaneous factors. The panelists voted on 51 proposed recommendations. Based on the panel vote, 51 recommendations were classified as either strong (43) or mild (8). Additional research is needed on CGM performance in the hospital. This consensus report is intended to support that type of research intended to improve outcomes for hospitalized people with diabetes.
Collapse
Affiliation(s)
- Elias K. Spanakis
- Baltimore VA Medical Center, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Curtiss B. Cook
- Division of Endocrinology, Mayo Clinic Arizona, Scottsdale, AZ, USA
| | - Kristen Kulasa
- Division of Endocrinology and Metabolism, Department of Medicine, University of California, San Diego, La Jolla, CA, USA
| | - Joseph A. Aloi
- Atrium Health Wake Forest Baptist, Winston-Salem, NC, USA
| | - Lia Bally
- Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | - Georgia Davis
- Emory University School of Medicine, Atlanta, GA, USA
| | - Kathleen M. Dungan
- Division of Endocrinology, Diabetes & Metabolism, The Ohio State University, Columbus, OH, USA
| | | | | | | | - Viral N. Shah
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, CO, USA
| | | | | | - Tiffany Tian
- Diabetes Technology Society, Burlingame, CA, USA
| | | | | | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| |
Collapse
|
10
|
Gomez LA, Toye AA, Hum RS, Kleinberg S. Simulating Realistic Continuous Glucose Monitor Time Series By Data Augmentation. J Diabetes Sci Technol 2023:19322968231181138. [PMID: 37350111 DOI: 10.1177/19322968231181138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/24/2023]
Abstract
BACKGROUND Simulated data are a powerful tool for research, enabling benchmarking of blood glucose (BG) forecasting and control algorithms. However, expert created models provide an unrealistic view of real-world performance, as they lack the features that make real data challenging, while black-box approaches such as generative adversarial networks do not enable systematic tests to diagnose model performance. METHODS To address this, we propose a method that learns missingness and error properties of continuous glucose monitor (CGM) data collected from people with type 1 diabetes (OpenAPS, OhioT1DM, RCT, and Racial-Disparity), and then augments simulated BG data with these properties. On the task of BG forecasting, we test how well our method brings performance closer to that of real CGM data compared with current simulation practices for missing data (random dropout) and error (Gaussian noise, CGM error model). RESULTS Our methods had the smallest performance difference versus real data compared with random dropout and Gaussian noise when individually testing the effects of missing data and error on simulated BG in most cases. When combined, our approach was significantly better than Gaussian noise and random dropout for all data sets except OhioT1DM. Our error model significantly improved results on diverse data sets. CONCLUSIONS We find a significant gap between BG forecasting performance on simulated and real data, and our method can be used to close this gap. This will enable researchers to rigorously test algorithms and provide realistic estimates of real-world performance without overfitting to real data or at the expense of data collection.
Collapse
Affiliation(s)
| | | | - R Stanley Hum
- The Montreal Children's Hospital, McGill University Health Centre, Montreal, QC, Canada
| | | |
Collapse
|
11
|
Setford S, Phillips S, Cameron H, Grady M. Updated Post-Market Surveillance of the Clinical Accuracy of a Blood Glucose Test Strip Platform. J Diabetes Sci Technol 2023; 17:860-861. [PMID: 36825330 PMCID: PMC10210116 DOI: 10.1177/19322968231158394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
|
12
|
Rimskaya AM, Krasnovidova AE, Vitebskaya AV. Practicalities of Flash-monitoring systems utilization in the questionnaire survey of children and adolescents with type 1 diabetes mellitus. DIABETES MELLITUS 2023. [DOI: 10.14341/dm12889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
Abstract
BACKGROUND: Children and adolescents with type 1 diabetes mellitus (T1DM) are recommended to perform self-control 6–10 times a day to maintain optimal blood glucose levels. Currently, there are various devices, such as glucometers, systems for continuous blood glucose monitoring and flash monitoring (FMS). In real clinical practice patients can combine the use of various devices and face with problems of their exploitation.AIM: To investigate the peculiarities of FMS utilization by children and adolescents with T1DM using questionnaire survey.MATERIALS AND METHODS: From 06.2020 till 05.2021, a survey of patients with T1DM was conducted as part of a single-center, observational, one-stage, uncontrolled study. The questionnaire contained questions regarding the number of measurements, circumstances and adverse reactions when using the devices.RESULTS: We questioned 80 patients (47 girls and 33 boys) aged 11.7 (9.0; 14.0) years with DM1 for 4.9 (2.0; 7.0) years, HbA1c level 8.2 (6.8; 9.0)) which were in pediatric endocrinology department of the University Children’s Clinical Hospital.The majority of patients (86.3%) scan the sensor more than 10 times a day; 25% of FMS-users measure blood glucose with glucometer not every day.The majority of patients (51,3%) prefer to use FMS instead of glucometer in all circumstances. Patients face with errors using FMS more often than using glucometers — OR 3.4 (95% CI 1.7–6.8). Non-significant reaction to adhesive material disturbed 50.0% participants; one patient (1.3%) had to refuse FMS due to allergic reaction.Among possible reasons to refuse FMS patients often name error, skin sealing, high price, inflammation, inconvenience to wear a device.Additional measures for fixing FMS device are always used by 36,3% of patients, sometimes — 18,8%, in some situations (going in for sports, swimming, travelling, in case of unsticking at the end of term) — 15,0%.CONCLUSION: Quarter of FMS users double-check glycaemia values rarer than recommended. Patients face with error using FMS more often than using glucometer. Local reaction to adhesive material does not influence FMS utilization. The majority of patients use additional measures for fixing FMS devices.
Collapse
|
13
|
Setford S, Liu Z, McColl D, Phillips S, Cameron H, Grady M. Post-Market Surveillance Assessment of the Clinical Accuracy of a Blood Glucose Monitoring System with an Improved Algorithm for Enhanced Product Performance. J Diabetes Sci Technol 2023; 17:133-140. [PMID: 34463143 PMCID: PMC9846413 DOI: 10.1177/19322968211039465] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND On-going manufacturer-led post-market surveillance (PMS), assessing the clinical accuracy of blood glucose monitoring (BGM) systems, is critical to substantiate the performance of such products for people with diabetes. MATERIALS AND METHODS Batches of Verio test-strip product were randomly and routinely selected over the period from launch of an improved-algorithm product to reporting date and sent to 3 clinic sites for clinician-led accuracy assessment. Accuracy is reported as per recently adopted FDA guidance for BGM systems, EN ISO 15197:2015 and MARD/MAD (Mean absolute relative difference/Mean absolute difference). RESULTS Thirty-three individual test-strip batches were evaluated corresponding to 506 unique donors. Accuracy performance - FDA: 98.9% of values within ±15% of comparator; ISO: 99.0% within ±15 mg/dL or ±15% at <100 mg/dL (<5.55 mmol/L) or ≥100 mg/dL (≥5.55 mmol/L) glucose, respectively. Overall MARD was 4.19% with a MARD range of 3.54%-5.73% across all test strip batches. CONCLUSIONS This post-market surveillance program demonstrates the new BGM system consistently meets measures of clinical accuracy specified by regulators. This program supports a growing demand by regulators for real-world evidence demonstrating consistent in-market product efficacy as opposed to the current largely passive approach that relies on assessment of reports filed by device users.
Collapse
Affiliation(s)
- Steven Setford
- LifeScan Scotland Ltd., Inverness,
UK
- Steven Setford, PhD, LifeScan Scotland Ltd,
Beechwood Park North, Inverness, Highland IV2 3ED, UK.
| | | | | | | | | | | |
Collapse
|
14
|
ElSayed NA, Aleppo G, Aroda VR, Bannuru RR, Brown FM, Bruemmer D, Collins BS, Hilliard ME, Isaacs D, Johnson EL, Kahan S, Khunti K, Leon J, Lyons SK, Perry ML, Prahalad P, Pratley RE, Seley JJ, Stanton RC, Gabbay RA. 7. Diabetes Technology: Standards of Care in Diabetes-2023. Diabetes Care 2023; 46:S111-S127. [PMID: 36507635 PMCID: PMC9810474 DOI: 10.2337/dc23-s007] [Citation(s) in RCA: 116] [Impact Index Per Article: 116.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The American Diabetes Association (ADA) "Standards of Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
15
|
Bellini A, Nicolò A, Rocchi JE, Bazzucchi I, Sacchetti M. Walking Attenuates Postprandial Glycemic Response: What Else Can We Do without Leaving Home or the Office? INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:253. [PMID: 36612575 PMCID: PMC9819328 DOI: 10.3390/ijerph20010253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/11/2022] [Accepted: 12/20/2022] [Indexed: 06/17/2023]
Abstract
We evaluated the effects of different exercise types suitable for a home/work setting on the postprandial glucose response. Twenty-three healthy, active, young individuals performed one of two studies (12 in Study 1 and 11 in Study 2), with four randomized protocols each. After a meal high in carbohydrate content (1 g of carbohydrate per kg of body weight), in Study 1, participants performed 30 min of either walking (WALK), bench stepping exercise (STEP) or isometric wall squat (SQUAT); in Study 2, participants performed 30 min of either walking (WALK), neuromuscular electrical stimulation alone (P_NMES) or superimposed on voluntary muscle contraction (VC_NMES). In both studies, participants performed a prolonged sitting condition (CON) that was compared to the exercise sessions. In Study 1, WALK and STEP significantly reduced the glucose peak compared to CON (p < 0.011). In Study 2, the peak was significantly reduced in WALK compared to CON, P_NMES and VC_NMES (p < 0.011) and in VC_NMES compared to CON and P_NMES (p < 0.011). A significant reduction of 3 h glucose iAUC was found for WALK and VC_NMES compared to CON and P_NMES (p < 0.033). In conclusion, WALK is the most effective strategy for improving the postprandial glycemic response. However, STEP and VC_NMES can also be used for reducing postprandial glycemia.
Collapse
|
16
|
Williams ME, Steenkamp D, Wolpert H. Making sense of glucose sensors in end-stage kidney disease: A review. FRONTIERS IN CLINICAL DIABETES AND HEALTHCARE 2022; 3:1025328. [PMID: 36992784 PMCID: PMC10012164 DOI: 10.3389/fcdhc.2022.1025328] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 10/27/2022] [Indexed: 12/23/2022]
Abstract
Diabetes mellitus remains the leading cause of end-stage kidney disease worldwide. Inadequate glucose monitoring has been identified as one of the gaps in care for hemodialysis patients with diabetes, and lack of reliable methods to assess glycemia has contributed to uncertainty regarding the benefit of glycemic control in these individuals. Hemoglobin A1c, the standard metric to evaluate glycemic control, is inaccurate in patients with kidney failure, and does not capture the full range of glucose values for patients with diabetes. Recent advances in continuous glucose monitoring have established this technology as the new gold standard for glucose management in diabetes. Glucose fluctuations are uniquely challenging in patients dependent on intermittent hemodialysis, and lead to clinically significant glycemic variability. This review evaluates continuous glucose monitoring technology, its validity in the setting of kidney failure, and interpretation of glucose monitoring results for the nephrologist. Continuous glucose monitoring targets for patients on dialysis have yet to be established. While continuous glucose monitoring provides a more complete picture of the glycemic profile than hemoglobin A1c and can mitigate high-risk hypoglycemia and hyperglycemia in the context of the hemodialysis procedure itself, whether the technology can improve clinical outcomes merits further investigation.
Collapse
Affiliation(s)
- Mark E. Williams
- Renal Unit, Joslin Diabetes Center, Boston MA, United States
- *Correspondence: Mark E. Williams,
| | - Devin Steenkamp
- Section of Endocrinology, Diabetes, and Nutrition, Department of Medicine, Boston Medical Center, Boston, MA, United States
| | - Howard Wolpert
- Boston University School of Medicine, Boston, MA, United States
| |
Collapse
|
17
|
Huang W, Li S, Lu J, Shen Y, Wang Y, Wang Y, Feng K, Huang X, Zou Y, Hu L, Lu Y, Zhou J, Li Y. Accuracy of the intermittently scanned continuous glucose monitoring system in critically ill patients: a prospective, multicenter, observational study. Endocrine 2022; 78:470-475. [PMID: 36227509 PMCID: PMC9559122 DOI: 10.1007/s12020-022-03216-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 09/30/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVE Continuous glucose monitoring (CGM) has the potential to improve glucose control in the intensive care unit (ICU) setting. We sought to evaluate the accuracy of the intermittently scanned CGM (isCGM) system in critically ill patients. RESEARCH DESIGN AND METHODS Adult patients were consecutively enrolled from three ICUs from August 2020 to January 2021. The performance of FreeStyle Libre Pro was evaluated against the venous blood glucose samples as a reference. Numerical accuracy was examined by the mean absolute relative difference (MARD), the Bland-Altman analysis, and the International Organization for Standardization criteria. Clinical accuracy was assessed by performing the Clarke and consensus error grid analysis. RESULTS A total of 122 patients were included and 3416 matched glucose pairs were analyzed. The overall MARD was 18.0%, and the highest MARD (33.1%) was observed in the hypoglycemic range (<70 mg/dL). The Bland-Altman analysis revealed a mean bias of -11.7 mg/dL, with the 95% limits of agreement of -73.0 to 49.5 mg/dL. The percentages of isCGM glucose values within ±15%/15, ±20%/20, and ±30%/30 mg/dL were 49.8%, 64.7%, and 84.5%, respectively. The Clarke and consensus error grid analysis showed acceptable clinical accuracy with 98.5% and 98.8% of glucose values falling into zones A and B. CONCLUSIONS Our study demonstrated suboptimal overall accuracy of isCGM for critically ill patients. Whether the adjunctive use of isCGM could improve glucose management and health outcomes in the critically ill needs further investigation. CLINICAL TRIAL REGISTRATION ChiCTR2100042036, Chinese Clinical Trial Registry.
Collapse
Affiliation(s)
- Weifeng Huang
- Department of Critical Care Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Siwan Li
- Department of Critical Care Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Jingyi Lu
- Department of Endocrinology and Metabolism, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yun Shen
- Department of Endocrinology and Metabolism, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yaxin Wang
- Department of Endocrinology and Metabolism, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Yufei Wang
- Department of Endocrinology and Metabolism, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Kaixuan Feng
- Department of Critical Care Medicine, Jinshan Branch of Shanghai Sixth People's Hospital, Shanghai, China
| | - Xiaoli Huang
- Department of Critical Care Medicine, Jinshan Branch of Shanghai Sixth People's Hospital, Shanghai, China
| | - Yan Zou
- Department of Critical Care Medicine, Lingang Campus of Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Linjie Hu
- Department of Epidemiology, Ministry of Education Key Laboratory of Public Health Safety, School of Public Health, Fudan University, Shanghai, China
| | - Yihan Lu
- Department of Epidemiology, Ministry of Education Key Laboratory of Public Health Safety, School of Public Health, Fudan University, Shanghai, China
| | - Jian Zhou
- Department of Endocrinology and Metabolism, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
| | - Yingchuan Li
- Department of Critical Care Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
- Department of Critical Care Medicine, Tongji University Affiliated Shanghai Tenth People's Hospital, Shanghai, China.
| |
Collapse
|
18
|
Longo RR, Joshi R. The Devil Is in the Details: Use, Limitations, and Implementation of Continuous Glucose Monitoring in the Inpatient Setting. Diabetes Spectr 2022; 35:405-419. [PMID: 36561647 PMCID: PMC9668728 DOI: 10.2337/dsi22-0009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Until recently, continuous glucose monitoring (CGM) systems were reserved for use in the outpatient setting or for investigational purposes in hospitalized patients. However, during the coronavirus disease 2019 pandemic, use of CGM in the inpatient setting has grown rapidly. This review outlines important details related to the accuracy, limitations, and implementation of, as well as necessary staff education for, inpatient CGM use and offers a glimpse into the future of CGM in the inpatient setting.
Collapse
Affiliation(s)
- Rebecca Rick Longo
- Lahey Hospital and Medical Center–Beth Israel Lahey Health, Burlington, MA
| | - Renu Joshi
- University of Pittsburgh Medical Center, Harrisburg, PA
| |
Collapse
|
19
|
Moriuchi T, Otaki Y, Satou H, Chai F, Hayashida Y, Aikawa R, Sugiyama T, Sode K. Clinical Study of a High Accuracy Green Design Blood Glucose Monitor Using an Innovative Optical Transmission Absorbance System. J Diabetes Sci Technol 2022; 16:1069-1075. [PMID: 34889119 PMCID: PMC9445325 DOI: 10.1177/19322968211060865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND Blood glucose monitoring (BGM) is essential for glycemic control in diabetic therapy. Followingly, accurate sensors are required for both daily personal and clinical use. The frequency of sensor use in patients with diabetes facilitates the use of disposable components. However, BGM systems are not exempt from green innovation sustainability initiatives. METHODS Clinical study of a high-accuracy green design blood glucose monitor using an innovative optical transmission absorbance system was carried out. Venous blood samples were collected from 104 patients with type II diabetes. The heat resistance of sensor strips was evaluated by storing sensor strips at 25℃ and 60℃ for approximately 3 months. Accuracy of the BGM system was evaluated via the ISO 15197:2013 protocol. RESULTS The BGM system achieved ±7.1% accuracy in glycemic level measurement, with 84% of all measurements within ±5% of the reference values. Furthermore, the sensor strip demonstrated heat resistance for more than 3 months when stored at 60℃. CONCLUSIONS A new, highly accurate BGM system was developed based on the latest optical measurement system, introducing a rare metal-free "green-strip." The developed BGM system achieved the highest reported accuracy in clinical research, using venous blood from patients with diabetes. The sensor strip also exhibited high heat resistance, reducing limitations on storage conditions.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Koji Sode
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC, USA
- Koji Sode, PhD, Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC 27599, USA.
| |
Collapse
|
20
|
Longo RR, Elias H, Khan M, Seley JJ. Use and Accuracy of Inpatient CGM During the COVID-19 Pandemic: An Observational Study of General Medicine and ICU Patients. J Diabetes Sci Technol 2022; 16:1136-1143. [PMID: 33971753 PMCID: PMC9445343 DOI: 10.1177/19322968211008446] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
BACKGROUND Continuous glucose monitoring (CGM) is widely used in the outpatient setting for people with diabetes and has been limited to investigational use only for the inpatient population. In April 2020, the US FDA exercised enforcement discretion for the temporary use of inpatient CGM during the pandemic, thus hospitals were presented the opportunity to implement this technology. METHODS We sought to investigate the accuracy of CGM in hospitalized patients on general care floors and the intensive care unit (ICU) in attempts to decrease healthcare professional exposure to COVID-19 and ultimately improve glycemic management of patients affected by COVID-19. Point of care (POC) and laboratory (Lab) glucose values were matched with simultaneous CGM glucose values and measures of accuracy were performed to evaluate the safety and usability of CGM in this population. Our data are presented drawing a distinction between POC and Lab as reference glucose sources. RESULTS In 808 paired samples obtained from 28 patients (10 ICU, 18 general floor), overall mean absolute relative difference (MARD) for all patients using either POC or Lab as reference was 13.2%. When using POC as the reference glucose MARD was 13.9% and using Lab glucose as reference 10.9%. Using both POC and Lab reference glucose pairs the overall MARD for critical care patients was 12.1% and for general floor patients 14%. CONCLUSION We determined, with proper protocols and safeguards in place, use of CGM in the hospitalized patient is a reasonable alternative to standard of care to achieve the goal of reducing healthcare professional exposure. Further study is necessary to validate safety, accuracy, and efficacy of this technology. Investigation and analysis are necessary for the development of protocols to utilize CGM trend arrows, alerts, and alarms.
Collapse
Affiliation(s)
- Rebecca Rick Longo
- Lahey Hospital and Medical Center, Burlington, MA, USA
- Rebecca Rick Longo, ACNP-BC, MSN, CDCES, Lahey Hospital and Medical Center, 41 Mall Road, Burlington, MA 01805, USA.
| | - Heather Elias
- Lahey Hospital and Medical Center, Burlington, MA, USA
| | - Mehvish Khan
- Lahey Hospital and Medical Center, Burlington, MA, USA
| | | |
Collapse
|
21
|
Freckmann G, Baumstark A, Jendrike N, Mende J, Schauer S, Link M, Pleus S, Haug C. Impact of Two Different Reference Measurement Procedures on Apparent System Accuracy of 18 CE-Marked Current-Generation Blood Glucose Monitoring Systems. J Diabetes Sci Technol 2022; 16:1076-1088. [PMID: 32814455 PMCID: PMC9445332 DOI: 10.1177/1932296820948873] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
BACKGROUND Measurement accuracy has been assessed for many different blood glucose monitoring systems (BGMS) over the years by different study groups. However, the choice of the comparison measurement procedure may impact the apparent level of accuracy found in such studies. MATERIALS AND METHODS Measurement accuracy of 18 different BGMS was assessed in a setting based on ISO 15197 using two different comparison methods in parallel: a glucose oxidase (GOD)-based and a hexokinase (HK)-based method. Accuracy limits of ISO 15197 were applied, and additional analyses were performed, including bias, linear regression, and mean absolute relative difference (MARD) to assess the impact of possible differences between comparison methods on the apparent level of accuracy. RESULTS While ≈80% of BGMS met the accuracy criteria of ISO 15197 when compared with the respective manufacturers' reference measurement procedure, only two-thirds did so against both comparison methods. The mean relative bias ranged from -6.6% to +5.7% for the analysis against the GOD-based method and from -11.1% to +1.3% for the analysis against the HK-based method, whereas MARD results ranged from 3.7% to 9.8% and from 2.3% to 10.5%, respectively. Results of regression analysis showed slopes between 0.85 and 1.08 (GOD-based method) and between 0.81 and 1.01 (HK-based method). CONCLUSIONS The results of this study indicate that there are systematic differences between the reference measurement procedures used for BGMS calibration as well as for system accuracy assessment. Because of the potential impact on therapy of patients with diabetes resulting from these differences, further steps toward harmonization of the measurement procedures' results are important.
Collapse
Affiliation(s)
- Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Annette Baumstark
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Nina Jendrike
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Jochen Mende
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Sebastian Schauer
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Manuela Link
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Stefan Pleus
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
- Stefan Pleus, MSc, Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Lise-Meitner-Straße 8/2, Ulm, D-89081, Germany.
| | - Cornelia Haug
- Institut für Diabetes-Technologie, Forschungs-und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| |
Collapse
|
22
|
Huang J, Yeung AM, Nguyen KT, Xu NY, Preiser JC, Rushakoff RJ, Seley JJ, Umpierrez GE, Wallia A, Drincic AT, Gianchandani R, Lansang MC, Masharani U, Mathioudakis N, Pasquel FJ, Schmidt S, Shah VN, Spanakis EK, Stuhr A, Treiber GM, Klonoff DC. Hospital Diabetes Meeting 2022. J Diabetes Sci Technol 2022; 16:1309-1337. [PMID: 35904143 PMCID: PMC9445340 DOI: 10.1177/19322968221110878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The annual Virtual Hospital Diabetes Meeting was hosted by Diabetes Technology Society on April 1 and April 2, 2022. This meeting brought together experts in diabetes technology to discuss various new developments in the field of managing diabetes in hospitalized patients. Meeting topics included (1) digital health and the hospital, (2) blood glucose targets, (3) software for inpatient diabetes, (4) surgery, (5) transitions, (6) coronavirus disease and diabetes in the hospital, (7) drugs for diabetes, (8) continuous glucose monitoring, (9) quality improvement, (10) diabetes care and educatinon, and (11) uniting people, process, and technology to achieve optimal glycemic management. This meeting covered new technology that will enable better care of people with diabetes if they are hospitalized.
Collapse
Affiliation(s)
| | | | | | - Nicole Y. Xu
- Diabetes Technology Society, Burlingame, CA, USA
| | | | | | | | | | - Amisha Wallia
- Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | | | | | | | - Umesh Masharani
- University of California San Francisco, San Francisco, CA, USA
| | | | | | | | - Viral N. Shah
- Barbara Davis Center for Diabetes, University of Colorado, Aurora, CO, USA
| | | | | | | | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
- David C. Klonoff, MD, FACP, FRCP (Edin), Fellow AIMBE, Diabetes Research Institute, Mills-Peninsula Medical Center, 100 South San Mateo Drive, Room 5147, San Mateo, CA 94401, USA.
| |
Collapse
|
23
|
Pleus S, Freckmann G, Schauer S, Heinemann L, Ziegler R, Ji L, Mohan V, Calliari LE, Hinzmann R. Self-Monitoring of Blood Glucose as an Integral Part in the Management of People with Type 2 Diabetes Mellitus. Diabetes Ther 2022; 13:829-846. [PMID: 35416589 PMCID: PMC9076772 DOI: 10.1007/s13300-022-01254-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 03/14/2022] [Indexed: 11/25/2022] Open
Abstract
For decades, self-monitoring of blood glucose (SMBG) has been considered a cornerstone of adequate diabetes management. Structured SMBG can follow different monitoring patterns, and it results in improved glycemic control, reduced hypoglycemia, and a better quality of life of people with diabetes. The technology, usability, and accuracy of SMBG systems have advanced markedly since their introduction a few decades ago. Current SMBG systems are small and easy to use, require small (capillary) blood sample volumes, and provide measurement results within seconds. In addition, devices are increasingly equipped with features such as connectivity to other devices and/or digital diaries and diabetes management tools. Although measurement quality can come close to or equal that of the glucose monitoring systems used by healthcare professionals, several available SMBG systems still do not meet internationally accepted accuracy standards, such as the International Organization for Standardization 15197 standard. Reports from China, India, and Brazil based on local experience suggest that in addition of the accuracy issues of SMBG systems, other obstacles also need to be overcome to optimize SMBG usage. Nonetheless, adequate usage of SMBG data is of high relevance for the management of people with type 2 diabetes mellitus.
Collapse
Affiliation(s)
- Stefan Pleus
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Sebastian Schauer
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | | | - Ralph Ziegler
- Diabetes Clinic for Children and Adolescents, Muenster, Germany
| | - Linong Ji
- Peking University People's Hospital, Peking, China
| | - Viswanathan Mohan
- Dr. Mohan's Diabetes Specialities Centre, Chennai, India
- Madras Diabetes Research Foundation, Chennai, India
| | - Luis Eduardo Calliari
- Pediatric Endocrine Unit, Pediatric Department, Santa Casa School of Medical Department, Santa Casa School of Medical Sciences, Sao Paulo, Brazil
| | - Rolf Hinzmann
- Roche Diabetes Care GmbH, Sandhofer Straße 116, 68305, Mannheim, Germany.
| |
Collapse
|
24
|
Eichenlaub M, Pleus S, Shaginian R, Richardson J, Pardo S, Stuhr A, Freckmann G. Impact of Blood Glucose Monitoring System Accuracy on Clinical Decision Making for Diabetes Management. J Diabetes Sci Technol 2022; 17:683-689. [PMID: 35227125 DOI: 10.1177/19322968221080916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND The accuracy of blood glucose monitoring systems (BGMS) is crucial for the safe and effective management of diabetes mellitus. Despite standardization of accuracy assessment procedures and requirements, various studies have shown that the accuracy of BGMS on the market can vary considerably. This article therefore provides health care professionals and users with an intuitive illustration of the impact of BGMS accuracy on clinical decision making. MATERIAL AND METHODS Several hypothetical patient scenarios based on blood glucose (BG) levels in the low, normal, and high BG range are devised. Using data from a recent BGMS accuracy study, a method for calculating the expected range of BG readings from four examined BGMS at the selected BG levels is introduced. Based on these ranges, it is illustrated how clinical decisions and subsequent outcomes of the hypothetical patients are affected by the expected inaccuracies of the BGMS. RESULTS The range of expected BGMS readings for the same true BG level can vary considerably between different BGMS. The discussion of hypothetical patient scenarios revealed that the use of some BGMS could be associated with an increased risk of adverse events such as failure to detect hypoglycemia, driving with an unsafe BG level, delay of treatment intervention in diabetes during pregnancy, or the failure to prevent diabetic ketoacidosis. CONCLUSIONS This article can support both health care professionals and patients to understand the impact of BGMS accuracy in a relatable, clinical context. Furthermore, it is suggested that current accuracy requirements might be insufficient for the prevention of adverse clinical outcomes in certain circumstances.
Collapse
Affiliation(s)
- Manuel Eichenlaub
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Stefan Pleus
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| | - Rimma Shaginian
- Ascensia Diabetes Care Holdings AG, Global Medical Affairs, Basel, Switzerland
| | - James Richardson
- Ascensia Diabetes Care Holdings AG, Global Medical Affairs, Basel, Switzerland
| | - Scott Pardo
- Ascensia Diabetes Care, Global Clinical Affairs, Valhalla, USA
| | - Andreas Stuhr
- Ascensia Diabetes Care, Global Medical Affairs, Parsippany, USA
| | - Guido Freckmann
- Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany
| |
Collapse
|
25
|
Abstract
The American Diabetes Association (ADA) "Standards of Medical Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee (https://doi.org/10.2337/dc22-SPPC), are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations, please refer to the Standards of Care Introduction (https://doi.org/10.2337/dc22-SINT). Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
26
|
Preoperative optimization of diabetes. Int Anesthesiol Clin 2022; 60:8-15. [PMID: 34897217 DOI: 10.1097/aia.0000000000000351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
Glavas MM, Lee AY, Miao I, Yang F, Mojibian M, O'Dwyer SM, Kieffer TJ. Developmental Timing of High-Fat Diet Exposure Impacts Glucose Homeostasis in Mice in a Sex-Specific Manner. Diabetes 2021; 70:2771-2784. [PMID: 34544729 PMCID: PMC8660987 DOI: 10.2337/db21-0310] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 09/03/2021] [Indexed: 11/24/2022]
Abstract
We previously demonstrated that male, but not female, Swiss Webster mice are susceptible to diabetes, with incidence increased by early overnutrition and high-fat diet (HFD). In this study, we investigated how HFD in Swiss Webster males and females during preweaning, peripubertal, and postpubertal periods alters glucose homeostasis and diabetes susceptibility. In males, HFD throughout life resulted in the highest diabetes incidence. Notably, switching to chow postpuberty was protective against diabetes relative to switching to chow at weaning, despite the longer period of HFD exposure. Similarly, HFD throughout life in males resulted in less liver steatosis relative to mice with shorter duration of postpubertal HFD. Thus, HFD timing relative to weaning and puberty, not simply exposure length, contributes to metabolic outcomes. Females were protected from hyperglycemia regardless of length or timing of HFD. However, postpubertal HFD resulted in a high degree of hepatic steatosis and adipose fibrosis, but glucose regulation and insulin sensitivity remained unchanged. Interestingly, peri-insulitis was observed in the majority of females but was not correlated with impaired glucose regulation. Our findings reveal critical periods of HFD-induced glucose dysregulation with striking sex differences in Swiss Webster mice, highlighting the importance of careful consideration of HFD timing relative to critical developmental periods.
Collapse
Affiliation(s)
- Maria M Glavas
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Ann Y Lee
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Ian Miao
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Fan Yang
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Majid Mojibian
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Shannon M O'Dwyer
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Timothy J Kieffer
- Department of Cellular and Physiological Sciences, Life Sciences Institute, University of British Columbia, Vancouver, British Columbia, Canada
- Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada
- School of Biomedical Engineering, University of British Columbia, Vancouver, British Columbia, Canada
| |
Collapse
|
28
|
Kim HN, Yoon S. Simultaneous point-of-care testing of blood lipid profile and glucose: Performance evaluation of the GCare Lipid Analyzer. J Clin Lab Anal 2021; 35:e24055. [PMID: 34697832 PMCID: PMC8649338 DOI: 10.1002/jcla.24055] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 09/06/2021] [Accepted: 09/30/2021] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Point-of-care (POC) testing provides quick results and includes tests for blood glucose and lipid profiles. We evaluated the newly developed POC device, the GCare Lipid Analyzer, which is used to measure glucose, total cholesterol (TC), triglyceride (TG), and high-density lipoprotein cholesterol (HDL-C) levels. METHODS Venous and capillary blood samples were collected from patients who visited Korea University Guro Hospital. The results obtained using the GCare Lipid Analyzer were compared with those obtained using the TBA 2000FR chemistry analyzer and YSI 2300 STAT Plus analyzer. The glucose system evaluation process was based on the International Organization for Standardization 15197:2013 guidelines. RESULTS The correlation coefficients (R) for TC, TG, and HDL-C were 0.965, 0.969, and 0.943 in capillary blood and 0.969, 0.990, and 0.956 in venous blood, respectively. The total errors for TC, TG, and HDL-C of the lipid profile using venous blood were all acceptable at 6.6%, 9.3%, and 11.6%, respectively. For glucose concentrations <100 mg/dl, 96.1% of the measured glucose levels were within ±15 mg/dl in venous samples and 100% were within ±15 mg/dl in capillary samples. For glucose concentrations ≥100 mg/dl, 100% and 99.5% of the measured glucose levels were within 15% for venous and capillary blood, respectively. CONCLUSION The performance of the GCare Lipid Analyzer is acceptable for both blood glucose and lipid profile testing, indicating that it is reliable for use in patients with diabetic dyslipidemia.
Collapse
Affiliation(s)
- Ha Nui Kim
- Department of Laboratory MedicineKorea University Guro HospitalSeoulKorea
| | - Soo‐Young Yoon
- Department of Laboratory MedicineKorea University Guro HospitalSeoulKorea
| |
Collapse
|
29
|
O'Brien MJ, Stephen JJ, Norton KL, Meehan TP, Vojta D, Ackermann RT. Integrating diabetes technologies with team-based primary care for type 2 diabetes: A pilot trial. Prim Care Diabetes 2021; 15:1104-1106. [PMID: 34301495 PMCID: PMC9172266 DOI: 10.1016/j.pcd.2021.07.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 06/21/2021] [Accepted: 07/15/2021] [Indexed: 10/20/2022]
Abstract
This pilot trial studied a novel intervention that integrated diabetes technologies into team-based primary care for type 2 diabetes. We found clinically significant reductions in blood pressure, weight, and glucose. The latter two were statistically significant.
Collapse
Affiliation(s)
- Matthew J O'Brien
- Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Institute of Public Health and Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Division of General Internal Medicine and Geriatrics, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States.
| | - John J Stephen
- Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Division of General Internal Medicine and Geriatrics, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
| | | | | | | | - Ronald T Ackermann
- Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Institute of Public Health and Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Division of General Internal Medicine and Geriatrics, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
| |
Collapse
|
30
|
Holt RIG, DeVries JH, Hess-Fischl A, Hirsch IB, Kirkman MS, Klupa T, Ludwig B, Nørgaard K, Pettus J, Renard E, Skyler JS, Snoek FJ, Weinstock RS, Peters AL. The management of type 1 diabetes in adults. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetologia 2021; 64:2609-2652. [PMID: 34590174 PMCID: PMC8481000 DOI: 10.1007/s00125-021-05568-3] [Citation(s) in RCA: 120] [Impact Index Per Article: 40.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) convened a writing group to develop a consensus statement on the management of type 1 diabetes in adults. The writing group has considered the rapid development of new treatments and technologies and addressed the following topics: diagnosis, aims of management, schedule of care, diabetes self-management education and support, glucose monitoring, insulin therapy, hypoglycaemia, behavioural considerations, psychosocial care, diabetic ketoacidosis, pancreas and islet transplantation, adjunctive therapies, special populations, inpatient management and future perspectives. Although we discuss the schedule for follow-up examinations and testing, we have not included the evaluation and treatment of the chronic microvascular and macrovascular complications of diabetes as these are well-reviewed and discussed elsewhere. The writing group was aware of both national and international guidance on type 1 diabetes and did not seek to replicate this but rather aimed to highlight the major areas that healthcare professionals should consider when managing adults with type 1 diabetes. Though evidence-based where possible, the recommendations in the report represent the consensus opinion of the authors. Graphical abstract.
Collapse
Affiliation(s)
- Richard I G Holt
- Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, UK.
- Southampton National Institute for Health Research Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, UK.
| | - J Hans DeVries
- Amsterdam UMC, Internal Medicine, University of Amsterdam, Amsterdam, the Netherlands
- Profil Institute for Metabolic Research, Neuss, Germany
| | - Amy Hess-Fischl
- Kovler Diabetes Center, University of Chicago, Chicago, IL, USA
| | - Irl B Hirsch
- UW Medicine Diabetes Institute, Seattle, WA, USA
| | - M Sue Kirkman
- University of North Carolina School of Medicine, Chapel Hill, NC, USA
| | - Tomasz Klupa
- Department of Metabolic Diseases, Center for Advanced Technologies in Diabetes, Jagiellonian University Medical College, Kraków, Poland
| | - Barbara Ludwig
- University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Kirsten Nørgaard
- Steno Diabetes Center Copenhagen, Gentofte, Denmark
- University of Copenhagen, Copenhagen, Denmark
| | | | - Eric Renard
- Montpellier University Hospital, Montpellier, France
- Institute of Functional Genomics, University of Montpellier, CNRS, Inserm, Montpellier, France
| | - Jay S Skyler
- University of Miami Miller School of Medicine, Miami, FL, USA
| | - Frank J Snoek
- Amsterdam UMC, Medical Psychology, Vrije Universiteit, Amsterdam, the Netherlands
| | | | - Anne L Peters
- Keck School of Medicine of USC, Los Angeles, CA, USA
| |
Collapse
|
31
|
Holt RIG, DeVries JH, Hess-Fischl A, Hirsch IB, Kirkman MS, Klupa T, Ludwig B, Nørgaard K, Pettus J, Renard E, Skyler JS, Snoek FJ, Weinstock RS, Peters AL. The Management of Type 1 Diabetes in Adults. A Consensus Report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetes Care 2021; 44:2589-2625. [PMID: 34593612 DOI: 10.2337/dci21-0043] [Citation(s) in RCA: 202] [Impact Index Per Article: 67.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 08/25/2021] [Indexed: 02/03/2023]
Abstract
The American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) convened a writing group to develop a consensus statement on the management of type 1 diabetes in adults. The writing group has considered the rapid development of new treatments and technologies and addressed the following topics: diagnosis, aims of management, schedule of care, diabetes self-management education and support, glucose monitoring, insulin therapy, hypoglycemia, behavioral considerations, psychosocial care, diabetic ketoacidosis, pancreas and islet transplantation, adjunctive therapies, special populations, inpatient management, and future perspectives. Although we discuss the schedule for follow-up examinations and testing, we have not included the evaluation and treatment of the chronic microvascular and macrovascular complications of diabetes as these are well-reviewed and discussed elsewhere. The writing group was aware of both national and international guidance on type 1 diabetes and did not seek to replicate this but rather aimed to highlight the major areas that health care professionals should consider when managing adults with type 1 diabetes. Though evidence-based where possible, the recommendations in the report represent the consensus opinion of the authors.
Collapse
Affiliation(s)
- Richard I G Holt
- Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, U.K. .,Southampton National Institute for Health Research Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust, Southampton, U.K
| | - J Hans DeVries
- Amsterdam UMC, Internal Medicine, University of Amsterdam, Amsterdam, the Netherlands.,Profil Institute for Metabolic Research, Neuss, Germany
| | | | | | - M Sue Kirkman
- University of North Carolina School of Medicine, Chapel Hill, NC
| | - Tomasz Klupa
- Department of Metabolic Diseases, Center for Advanced Technologies in Diabetes, Jagiellonian University Medical College, Kraków, Poland
| | - Barbara Ludwig
- University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Kirsten Nørgaard
- Steno Diabetes Center Copenhagen, Gentofte, Denmark.,University of Copenhagen, Copenhagen, Denmark
| | | | - Eric Renard
- Montpellier University Hospital, Montpellier, France.,Institute of Functional Genomics, University of Montpellier, CNRS, Inserm, Montpellier, France
| | - Jay S Skyler
- University of Miami Miller School of Medicine, Miami, FL
| | - Frank J Snoek
- Amsterdam UMC, Medical Psychology, Vrije Universiteit, Amsterdam, the Netherlands
| | | | | |
Collapse
|
32
|
Klaff L, Shelat P, Zondorak D, Wayland-Smith A, Vernes P, Richardson JM. Accuracy and User Performance of a New Blood Glucose Monitoring System. J Diabetes Sci Technol 2021; 15:1382-1389. [PMID: 33243009 PMCID: PMC8655271 DOI: 10.1177/1932296820974348] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Self-monitoring of blood glucose (BG) is important in diabetes management, allowing people with diabetes (PWD) to assess responses to diabetes therapy and to inform if they are attaining their glycemic targets. This study assessed the accuracy and user performance (UP) of a new blood glucose monitoring system (BGMS), CONTOUR®PLUS ELITE, according to International Organization for Standardization (ISO) 15197:2013 criteria and also more stringent criteria. METHODS In laboratory Study 1, capillary fingertip blood samples from 100 PWD were evaluated using the new BGMS. In clinical Study 2, 130 PWD had Yellow Springs Instrument (YSI) analyzer reference measurements against subject-obtained fingertip and palm blood, and trial staff-obtained venous blood. The new BGMS was tested with test strips from three different lots. A UP questionnaire assessed ease of use. RESULTS Study 1: 100% of combined accuracy results fulfilled ISO criteria (±15 mg/dL at BG <100 mg/dL; ±15% at BG ≥100 mg/dL); 99.8% fulfilled more stringent criteria (±10 mg/dL at BG <100 mg/dL; ±10% at BG ≥100 mg/dL). Error grid analysis showed that 100% of results were within zone A. Study 2: >98% of subject- and 100% of trial staff-obtained performance results met ISO criteria. Most subjects (>96%) found the BGMS easy to use. CONCLUSION The new BGMS exceeded minimum ISO 15197:2013-specified standards for both accuracy and UP criteria, along with the more stringent accuracy criteria. These data show that this new BGMS can be a useful tool in managing glycemic control for PWD.
Collapse
Affiliation(s)
- Leslie Klaff
- Rainier Clinical Research Center,
Renton, WA, USA
| | | | | | | | | | - James M. Richardson
- Ascensia Diabetes Care Holdings AG,
Basel, Switzerland
- James M. Richardson, MPharm, MBA, Medical
Affairs, Ascensia Diabetes Care Holdings AG, Peter Merian-Strasse 90, Basel,
4052, Switzerland.
| |
Collapse
|
33
|
A Pilot Trial to Evaluate the Accuracy of a Novel Non-Invasive Glucose Meter. SENSORS 2021; 21:s21206704. [PMID: 34695917 PMCID: PMC8538169 DOI: 10.3390/s21206704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 10/05/2021] [Accepted: 10/07/2021] [Indexed: 11/16/2022]
Abstract
The non-invasive self-monitoring of blood glucose (SMBG) has been the subject of intense investigation over recent decades. We conducted a pilot study designed to examine a novel non-invasive glucometer, the HGR GWave, utilizing radiofrequency (RF) sensing. Blood glucose levels assessed by this HGR prototype were compared to measurements performed by a hexokinase core laboratory assay during an oral glucose tolerance test (oGTT) for 5 subjects with type 2 diabetes. The HGR glucose meter readings were also compared to two Abbot Freestyle® glucose meters, which were also used for calibration. The accuracy of the results was evaluated through the calculation of relative absolute difference (RAD), specified percentage differences between 43 reference glucose measurements, and using comparator measurements. The median RAD was −4.787. We detected 79.04%, 92.99% and 97.64% of HGR readings within ±10%, ±15% and ±20% of the reference glucose measurements. The HGR readings had a high correlation with reference lab glucose measurements with R2 = 0.924 (95% CI 0.929–0.979; p < 0.0001). When compared to the Freestyle® glucose meters 94.3% and 100% of the readings were within ±5% and ±10%, with R2 = 0.975 (0.975–0.994; p < 0.0001). The HGR prototype glucose meter was found to be accurate in detecting real-time blood glucose during an oGTT in this small pilot study. A study with a broader range of blood glucose levels is needed to further assess its accuracy and its suitability for clinical use.
Collapse
|
34
|
Sheen Y, Huang C, Huang S, Lin C, Lee I, H‐H Sheu W. Electronic dashboard-based remote glycemic management program reduces length of stay and readmission rate among hospitalized adults. J Diabetes Investig 2021; 12:1697-1707. [PMID: 33421275 PMCID: PMC8409866 DOI: 10.1111/jdi.13500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/22/2020] [Accepted: 01/06/2021] [Indexed: 01/22/2023] Open
Abstract
AIMS/INTRODUCTION Currently, the impact of hospital-wide glycemic control interventions on length of hospital stay (LOS) and readmission rates are largely unknown. We investigated the impact of a 4-year hospital-wide remote glycemic management program on LOS and 30-day readmission rates among hospitalized adults who received glucose monitoring. MATERIALS AND METHODS In this retrospective study, hospitalized patients who received glucose monitoring were classified into groups 1 (high glucose variability), 2 (hypoglycemia), 3 (hyperglycemia) and 4 (relatively stable). The monthly percentage changes, and average monthly percentage changes of hyperglycemia, hypoglycemia and treat to target were determined using joinpoint regression analysis. RESULTS A total of 106,528 hospitalized patients (mean age 60.9 ± 18.5 years, 57% men) were enrolled. We observed a significant reduction in the percentage of inpatients in poor glycemic control groups (groups 1, 2 and 3, all P < 0.001), and a reciprocal increase in the relatively stable group (group 4) from 2016 to 2019. We found a significant reduction in LOS by 11.4% (10.5-9.3 days, P = 0.002, after adjustment for age, sex, and admission department). The 30-day readmission rate decreased from 29.9% to 29.3%, mainly among those in group 4 in 2019 (P < 0.001 after adjustment of sex, age, admission department and LOS). CONCLUSIONS Improved glycemic control through a hospital-wide electronic remote glycemic management system reduced LOS and 30-day readmission rates. Findings observed in this study might be associated with the reduction in cost of avoidable hospitalizations.
Collapse
Affiliation(s)
- Yi‐Jing Sheen
- Division of Endocrinology and MetabolismDepartment of Internal MedicineTaichung Veterans General HospitalTaichungTaiwan
- Department of MedicineSchool of MedicineNational Yang‐Ming UniversityTaipeiTaiwan
| | - Chien‐Chung Huang
- Department of Computer & Communications CenterTaichung Veterans General HospitalTaichungTaiwan
| | - Shih‐Che Huang
- Division of Clinical InformationCenter of Quality ManagementTaichung Veterans General HospitalTaichungTaiwan
| | - Ching‐Heng Lin
- Department of Medical ResearchTaichung Veterans General HospitalTaichungTaiwan
| | - I‐Te Lee
- Division of Endocrinology and MetabolismDepartment of Internal MedicineTaichung Veterans General HospitalTaichungTaiwan
- Department of MedicineSchool of MedicineNational Yang‐Ming UniversityTaipeiTaiwan
- School of MedicineChung Shan Medical UniversityTaichung CityTaiwan
- College of ScienceTunghai UniversityTaichung CityTaiwan
| | - Wayne H‐H Sheu
- Division of Endocrinology and MetabolismDepartment of Internal MedicineTaichung Veterans General HospitalTaichungTaiwan
- Department of MedicineSchool of MedicineNational Yang‐Ming UniversityTaipeiTaiwan
- Institute of Medical TechnologyCollege of Life ScienceNational Chung‐Hsing UniversityTaichungTaiwan
- School of MedicineNational Defense Medical CenterTaipeiTaiwan
| |
Collapse
|
35
|
Li W, Luo W, Li M, Chen L, Chen L, Guan H, Yu M. The Impact of Recent Developments in Electrochemical POC Sensor for Blood Sugar Care. Front Chem 2021; 9:723186. [PMID: 34395386 PMCID: PMC8360348 DOI: 10.3389/fchem.2021.723186] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 07/19/2021] [Indexed: 12/21/2022] Open
Abstract
Rapid glucose testing is very important in the care of diabetes. Monitoring of blood glucose is the most critical indicator of disease control in diabetic patients. The invention and popularity of electrochemical sensors have made glucose detection fast and inexpensive. The first generation of glucose sensors had limitations in terms of sensitivity and selectivity. In order to overcome these problems, scientists have used a range of new materials to produce new glucose electrochemical sensors with higher sensitivity, selectivity and lower cost. A variety of different electrochemical sensors including enzymatic electrochemical sensors and enzyme-free electrochemical sensors have been extensively investigated. We discussed the development process of electrochemical glucose sensors in this review. We focused on describing the benefits of carbon materials in nanomaterials, specially graphene for sensors. In addition, we discussed the limitations of the sensors and challenges in future research.
Collapse
Affiliation(s)
- Wei Li
- ICU of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Weixiang Luo
- Nursing Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Mengyuan Li
- Hepatological Surgery Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Liyu Chen
- Endocrinology Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Liyan Chen
- Nursing Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Hua Guan
- Respiratory Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| | - Mengjiao Yu
- Gastroenterology Department of Shenzhen People's Hospital, 2nd Clinical Medical College of Jinan University, Shenzhen, China
| |
Collapse
|
36
|
Tanaka K, Higuchi R, Mizusawa K, Nakamura T, Nakajima K. Fasting biochemical hypoglycemia and related-factors in non-diabetic population: Kanagawa Investigation of Total Check-up Data from National Database-8. World J Diabetes 2021; 12:1131-1140. [PMID: 34326960 PMCID: PMC8311474 DOI: 10.4239/wjd.v12.i7.1131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/28/2021] [Accepted: 06/22/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND In healthy people, the lowest daily blood glucose concentration is usually observed in the early morning, after overnight fasting. However, the clinical relevance and the prevalence of fasting biochemical hypoglycemia (FBH) are poorly understood in people who do not have diabetes, although the clinical implications of such hypoglycemia have been extensively studied in patients with diabetes. FBH can be influenced by many factors, including age, sex, body mass, smoking, alcohol drinking, exercise levels, medications, and eating behaviors, such as breakfast skipping and late-night eating.
AIM To determine the prevalence of FBH and investigated its association with potential risk factors in a population without diabetes.
METHODS Clinical parameters and lifestyle-related factors were assessed in a cross-sectional study of 695613 people aged 40-74 years who had undergone a health check-up (390282 men and 305331 women). FBH was defined as fasting plasma glucose < 70 mg/dL (3.9 mmol/L) after overnight fasting, regardless of any symptoms. The absence of diabetes was defined as HbA1c < 6.5%, fasting plasma glucose < 126 mg/dL (7.0 mmol/L), and no pharmacotherapy for diabetes. Multivariate logistic regression analysis, with adjustment for confounding factors, was used to identify associations.
RESULTS FBH was present in 1842 participants (0.26%). There were significantly more women in the FBH group (59.1%) than in the non-FBH group (43.9%). Values of most of the clinical parameters, but not age, were significantly lower in the FBH group than in the non-FBH group. Logistic regression analysis showed that a body mass index of ≤ 20.9 kg/m2 (reference: 21-22.9 kg/m2) and current smoking were significantly associated with FBH, and this was not altered by adjustment for age, sex, and pharmacotherapy for hypertension or dyslipidemia. Female sex was associated with FBH. When the data were analyzed according to sex, men in their 60s or 70s appeared more likely to experience FBH compared with their 40s, whereas men in their 50s and women aged ≥ 50 years appeared less likely to experience FBH. The relationships of FBH with other factors including alcohol drinking and pharmacotherapies for hypertension and dyslipidemia also differed between men and women.
CONCLUSION FBH occurs even in non-diabetic people, albeit at a very low frequency. FBH is robustly associated with low body mass and smoking, and its relationship with lifestyle factors varies according to sex.
Collapse
Affiliation(s)
- Kotone Tanaka
- Graduate School of Health Innovation, Kanagawa University of Human Services, Kawasaki 210-0821, Japan
| | - Ryoko Higuchi
- School of Nutrition and Dietetics, Faculty of Health and Social Services, Kanagawa University of Human Services, Yokosuka 238-8522, Japan
| | - Kaori Mizusawa
- School of Nutrition and Dietetics, Faculty of Health and Social Services, Kanagawa University of Human Services, Yokosuka 238-8522, Japan
| | - Teiji Nakamura
- School of Nutrition and Dietetics, Faculty of Health and Social Services, Kanagawa University of Human Services, Yokosuka 238-8522, Japan
| | - Kei Nakajima
- School of Nutrition and Dietetics, Faculty of Health and Social Services, Kanagawa University of Human Services, Yokosuka 238-8522, Japan
- Department of Endocrinology and Diabetes, Saitama Medical Center, Saitama Medical University, Kawagoe 350-8550, Japan
| |
Collapse
|
37
|
Pleus S, Heinemann L, Freckmann G, Nauck M, Tytko A, Kaiser P, Petersmann A. Glukosemessung in der Diabetesdiagnostik und -therapie: Laboratoriumsmedizinische Untersuchung inkl. patientennaher Sofortdiagnostik, Blutglukoseselbstmessung und kontinuierliches Glukosemonitoring. DIABETOL STOFFWECHS 2021. [DOI: 10.1055/a-1528-8248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
ZusammenfassungDie Glukose-„Messlandschaft“ in Deutschland deckt viele verschiedene Einsatzzwecke und -gebiete ab. Sie reicht von hochstandardisiert messenden Laboranalysesystemen mit einem großen Gesamtportfolio von Messgrößen bis hin zu einfachen Systemen für den Patientengebrauch. Aus klinischer Sicht muss die Qualität von Glukosemessungen ausreichend hoch sein, um die vorgesehenen Zwecke, also Diagnosestellung und Verlaufskontrolle, zu erfüllen.In der Heilkunde – also bei Messungen im Rahmen der Gesundheitsversorgung durch medizinisches Personal – definiert die Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen Vorgaben an die Qualitätssicherung. Es werden sowohl interne als auch externe (herstellerunabhängige) Qualitätskontrollen gefordert und mit spezifischen Vorgaben versehen. Diese Regelungen gelten demnach auch für alle Glukosemessungen in der Heilkunde, d. h. im Zentrallabor ebenso wie in der patientennahen Sofortdiagnostik.Bei dem Haupteinsatzgebiet von Glukosemessungen, der Verlaufskontrolle durch Patienten mit Diabetes im Rahmen der Blutglukoseselbstmessung, fehlen i. d. R. Kontrollen der Messqualität. Für das kontinuierliche Glukosemonitoring im interstitiellen Gewebe sind Qualitätskontrollen nach dem aktuellen technischen Stand sogar überhaupt nicht möglich. Hinzu kommt, dass eine regelmäßige herstellerunabhängige Kontrolle der Messqualität nicht vorgeschrieben ist. Ziel der Arbeit ist es, einen Überblick über die unterschiedlichen Glukosemesssysteme sowie praktische Aspekte und Probleme bei der Glukosemessung zu geben.
Collapse
Affiliation(s)
- Stefan Pleus
- n/a, Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Germany
| | - Lutz Heinemann
- Management, Science Consulting in Diabetes GmbH, Neuss, Germany
| | - Guido Freckmann
- n/a, Institut für Diabetes-Technologie Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Germany
| | - Matthias Nauck
- Institut für Klinische Chemie und Laboratoriumsmedizin, Universitätsmedizin Greifswald, Germany
- Partner Site Greifswald, DZHK, Greifswald, Germany
| | | | - Patricia Kaiser
- n/a, INSTAND Gesellschaft zur Förderung der Qualitätssicherung in medizinischen Laboratorien e.V., Düsseldorf, Germany
| | - Astrid Petersmann
- Institut für Klinische Chemie und Laboratoriumsmedizin, Universitätsmedizin Greifswald, Germany
- Universitätsinstitut für Klinische Chemie und Laboratoriumsmedizin, Klinikum Oldenburg AöR, Oldenburg, Germany
| |
Collapse
|
38
|
Mauldin K, Gieng J, Saarony D, Hu C. Performing nutrition assessment remotely via telehealth. Nutr Clin Pract 2021; 36:751-768. [PMID: 34101249 DOI: 10.1002/ncp.10682] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Performing nutrition assessment remotely via telehealth is a topic of significant interest given the global pandemic in 2020 that has necessitated physical distancing and virtual communications. This review presents an evidence-based approach to conducting nutrition assessments remotely. The authors present suggestions for adaptations that can be used to perform a remote nutrition-focused physical exam. Direct-to-consumer technologies that can be used in remote nutrition assessment are discussed and compared. Practice tips for conducting a telehealth visit are also presented. The aim of this publication is to provide interdisciplinary clinicians a set of guidelines and best practices for performing nutrition assessments in the era of telehealth.
Collapse
Affiliation(s)
- Kasuen Mauldin
- Department of Nutrition, Food Science, and Packaging, San José State University, San José, California, USA.,Clinical Nutrition, Stanford Health Care, Stanford, California, USA
| | - John Gieng
- Department of Nutrition, Food Science, and Packaging, San José State University, San José, California, USA
| | - Dania Saarony
- Clinical Nutrition, Stanford Health Care, Stanford, California, USA
| | - Catherine Hu
- Clinical Nutrition, Stanford Health Care, Stanford, California, USA
| |
Collapse
|
39
|
Grunberger G, Sherr J, Allende M, Blevins T, Bode B, Handelsman Y, Hellman R, Lajara R, Roberts VL, Rodbard D, Stec C, Unger J. American Association of Clinical Endocrinology Clinical Practice Guideline: The Use of Advanced Technology in the Management of Persons With Diabetes Mellitus. Endocr Pract 2021; 27:505-537. [PMID: 34116789 DOI: 10.1016/j.eprac.2021.04.008] [Citation(s) in RCA: 121] [Impact Index Per Article: 40.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 04/16/2021] [Accepted: 04/19/2021] [Indexed: 02/08/2023]
Abstract
OBJECTIVE To provide evidence-based recommendations regarding the use of advanced technology in the management of persons with diabetes mellitus to clinicians, diabetes-care teams, health care professionals, and other stakeholders. METHODS The American Association of Clinical Endocrinology (AACE) conducted literature searches for relevant articles published from 2012 to 2021. A task force of medical experts developed evidence-based guideline recommendations based on a review of clinical evidence, expertise, and informal consensus, according to established AACE protocol for guideline development. MAIN OUTCOME MEASURES Primary outcomes of interest included hemoglobin A1C, rates and severity of hypoglycemia, time in range, time above range, and time below range. RESULTS This guideline includes 37 evidence-based clinical practice recommendations for advanced diabetes technology and contains 357 citations that inform the evidence base. RECOMMENDATIONS Evidence-based recommendations were developed regarding the efficacy and safety of devices for the management of persons with diabetes mellitus, metrics used to aide with the assessment of advanced diabetes technology, and standards for the implementation of this technology. CONCLUSIONS Advanced diabetes technology can assist persons with diabetes to safely and effectively achieve glycemic targets, improve quality of life, add greater convenience, potentially reduce burden of care, and offer a personalized approach to self-management. Furthermore, diabetes technology can improve the efficiency and effectiveness of clinical decision-making. Successful integration of these technologies into care requires knowledge about the functionality of devices in this rapidly changing field. This information will allow health care professionals to provide necessary education and training to persons accessing these treatments and have the required expertise to interpret data and make appropriate treatment adjustments.
Collapse
Affiliation(s)
| | - Jennifer Sherr
- Yale University School of Medicine, New Haven, Connecticut
| | - Myriam Allende
- University of Puerto Rico School of Medicine, San Juan, Puerto Rico
| | | | - Bruce Bode
- Atlanta Diabetes Associates, Atlanta, Georgia
| | | | - Richard Hellman
- University of Missouri-Kansas City School of Medicine, Kansas City, Missouri
| | | | | | - David Rodbard
- Biomedical Informatics Consultants, LLC, Potomac, Maryland
| | - Carla Stec
- American Association of Clinical Endocrinology, Jacksonville, Florida
| | - Jeff Unger
- Unger Primary Care Concierge Medical Group, Rancho Cucamonga, California
| |
Collapse
|
40
|
Singh NK, Ray P, Carlin AF, Magallanes C, Morgan SC, Laurent LC, Aronoff-Spencer ES, Hall DA. Hitting the diagnostic sweet spot: Point-of-care SARS-CoV-2 salivary antigen testing with an off-the-shelf glucometer. Biosens Bioelectron 2021; 180:113111. [PMID: 33743492 PMCID: PMC7908832 DOI: 10.1016/j.bios.2021.113111] [Citation(s) in RCA: 71] [Impact Index Per Article: 23.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Revised: 02/15/2021] [Accepted: 02/22/2021] [Indexed: 12/19/2022]
Abstract
Significant barriers to the diagnosis of latent and acute SARS-CoV-2 infection continue to hamper population-based screening efforts required to contain the COVID-19 pandemic in the absence of widely available antiviral therapeutics or vaccines. We report an aptamer-based SARS-CoV-2 salivary antigen assay employing only low-cost reagents ($3.20/test) and an off-the-shelf glucometer. The test was engineered around a glucometer as it is quantitative, easy to use, and the most prevalent piece of diagnostic equipment globally, making the test highly scalable with an infrastructure that is already in place. Furthermore, many glucometers connect to smartphones, providing an opportunity to integrate with contact tracing apps, medical providers, and electronic health records. In clinical testing, the developed assay detected SARS-CoV-2 infection in patient saliva across a range of viral loads - as benchmarked by RT-qPCR - within 1 h, with 100% sensitivity (positive percent agreement) and distinguished infected specimens from off-target antigens in uninfected controls with 100% specificity (negative percent agreement). We propose that this approach provides an inexpensive, rapid, and accurate diagnostic for distributed screening of SARS-CoV-2 infection at scale.
Collapse
Affiliation(s)
- Naveen K. Singh
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093, USA
| | - Partha Ray
- Division of Surgical Oncology, Department of Surgery, Moores Cancer Center, University of California San Diego Health, La Jolla, CA, 92093, USA
| | - Aaron F. Carlin
- Division of Infectious Diseases and Global Public Health, Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA
| | - Celestine Magallanes
- Division of Maternal Fetal Medicine, Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California San Diego, La Jolla, CA, 92093, USA
| | - Sydney C. Morgan
- Division of Maternal Fetal Medicine, Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California San Diego, La Jolla, CA, 92093, USA
| | - Louise C. Laurent
- Division of Maternal Fetal Medicine, Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California San Diego, La Jolla, CA, 92093, USA
| | - Eliah S. Aronoff-Spencer
- Division of Infectious Diseases and Global Public Health, Department of Medicine, University of California San Diego, La Jolla, CA, 92093, USA,Corresponding author
| | - Drew A. Hall
- Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA, 92093, USA,Department of Bioengineering, University of California San Diego, La Jolla, CA, 92093, USA,Corresponding author
| |
Collapse
|
41
|
Flavel M, Jois M, Kitchen B. Potential contributions of the methodology to the variability of glycaemic index of foods. World J Diabetes 2021; 12:108-123. [PMID: 33594331 PMCID: PMC7839170 DOI: 10.4239/wjd.v12.i2.108] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 12/03/2020] [Accepted: 12/23/2020] [Indexed: 02/06/2023] Open
Abstract
Glycaemic index (GI) testing provides a useful point of comparison between carbohydrate sources. For this comparison to be meaningful, the methods used to determine GI values need to be rigorous and consistent between testing events. This requirement has led to increasing standardization of the GI methodology, with an international standard developed in joint consultation with FAO/WHO (ISO 26642:2010) currently the most up to date document. The purpose of this review is to compare the international standard to methods of published studies claiming to have performed a GI test. This analysis revealed that the international standard permits a wide range of choices for researchers when designing a GI testing plan, rather than a single standardized protocol. It has also been revealed that the literature contains significant variation, both between studies and from the international standard for critical aspects of GI testing methodology. The primary areas of variation include; what glucose specification is used, which reference food is used, how much reference food is given, what drink is given during testing, the blood sampling site chosen and what assay and equipment is used to measure blood glucose concentration. For each of these aspects we have explored some of the methodological and physiological implications of these variations. These insights suggest that whilst the international standard has assisted with framing the general parameters of GI testing, further stan-dardization to testing procedures is still required to ensure the continued relevance of the GI to clinical nutrition.
Collapse
Affiliation(s)
- Matthew Flavel
- Bioactive Division, The Product Makers, Keysborough 3173, Victoria, Australia
- School of Life Sciences, La Trobe University, Bundoora 3086, Australia
| | - Markandeya Jois
- School of Life Sciences, La Trobe University, Bundoora 3086, Australia
| | - Barry Kitchen
- Bioactive Division, The Product Makers, Keysborough 3173, Victoria, Australia
- School of Life Sciences, La Trobe University, Bundoora 3086, Australia
| |
Collapse
|
42
|
Alarcón-Gómez J, Calatayud J, Chulvi-Medrano I, Martín-Rivera F. Effects of a HIIT Protocol on Cardiovascular Risk Factors in a Type 1 Diabetes Mellitus Population. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:1262. [PMID: 33572499 PMCID: PMC7908515 DOI: 10.3390/ijerph18031262] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 01/22/2021] [Accepted: 01/27/2021] [Indexed: 12/13/2022]
Abstract
Cardiovascular complications are important causes of morbidity and mortality of Type 1 Diabetes Mellitus (T1DM) people. Regular exercise is strongly recommended to these patients due to its preventive action against this type of disease. However, a large percentage of patients with T1DM people present a sedentary behavior, mainly, because of the fear of a post-exercise hypoglycemia event and lack of time. High-intensity interval training (HIIT) is an efficient and safe methodology since it prevents hypoglycemia and does not require much time, which are the main barriers for this population to doing exercise and increasing physical conditioning. Nineteen sedentary adults (37 ± 6.5 years) with T1DM were randomly assigned to 6 weeks of either HIIT, 12 bouts first 2 weeks, 16 bouts in weeks 3 and 4, and 20 bouts in the last two weeks x 30-s intervals interspersed with 1-min rest periods, performed thrice weekly or to control group, which did not train. VO2max, body composition, heart rate variability (HRV), and fasting glucose were measured as cardiovascular risk factors. We suggest that the 6-week HIIT program used in the present study is safe since no severe hypoglycemia was reported and is an effective strategy in improving VO2max, body composition, HRV, and fasting glucose, which are important cardiovascular risk factors in T1DM people.
Collapse
Affiliation(s)
- Jesús Alarcón-Gómez
- Faculty of Physical Activity and Sports, University of Valencia, 46010 Valencia, Spain; or
| | - Joaquín Calatayud
- Exercise Intervention for Health Research Group (EXINH-RG), Department of Physiotherapy, University of Valencia, 46010 Valencia, Spain;
| | - Iván Chulvi-Medrano
- UIRFIDE (Sport Performance and Physical Fitness Research Group), Department of Physical and Sports Education, University of Valencia, 46010 Valencia, Spain
| | - Fernando Martín-Rivera
- Research Group in Prevention and Health in Exercise and Sport, Department of Physical and Sports Education, University of Valencia, 46010 Valencia, Spain;
| |
Collapse
|
43
|
Kim HN, Yoon SY. Comparative study of i-SENS glucometers in neonates using capillary blood samples. Clin Chem Lab Med 2021; 59:1133-1141. [PMID: 33915605 DOI: 10.1515/cclm-2020-1367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 01/07/2021] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The accuracy of point-of-care blood glucometers in the detection and evaluation of neonatal hypoglycemia is a concern. This study compared the performance of three i-SENS glucometers with that of the YSI 2300 STAT Plus Analyzer, which was used as a reference. METHODS The leftover neonatal capillary blood samples of 319 patients were used in this study. The evaluation process and accuracy performance criteria were based on the International Organization for Standardization 15197:2013 guidelines. The evaluation involved three i-SENS glucometers (BAROzen H Expert plus, CareSens PRO, and CareSens H Beat) and the ACCU-CHEK® Inform II glucometer. RESULTS The accuracy evaluation yielded acceptable results as follows: a) 100 and 100% for BAROzen H Expert plus; 99.8 and 100% for CareSens PRO; 98.7%, and 97.2% for CareSens H Beat glucometers were within the range of ±0.8 mmol/L (15 mg/dL) and ±15% of the average reference values at glucose concentrations <5.55 mmol/L (100 mg/dL) and ≥5.55 mmol/L (100 mg/dL), respectively, and b) all estimated glucose values (100%) were within the zones A and B of Consensus Error Grid for all three i-SENS glucometers. There was good correlation between the glucose values estimated by the glucometers and the reference values (R>0.990). CONCLUSIONS This study demonstrated that i-SENS glucometers exhibit acceptable performance and can be used as effective point-of-care devices in neonates.
Collapse
Affiliation(s)
- Ha Nui Kim
- Department of Laboratory Medicine, Korea University Guro Hospital, Seoul, Republic of Korea
| | - Soo-Young Yoon
- Department of Laboratory Medicine, Korea University Guro Hospital, Seoul, Republic of Korea
| |
Collapse
|
44
|
Dovc K, Battelino T. Time in range centered diabetes care. Clin Pediatr Endocrinol 2021; 30:1-10. [PMID: 33446946 PMCID: PMC7783127 DOI: 10.1297/cpe.30.1] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 09/17/2020] [Indexed: 12/11/2022] Open
Abstract
Optimal glycemic control remains challenging and elusive for many people with diabetes. With the comprehensive clinical evidence on safety and efficiency in large populations, and with broader reimbursement, the adoption of continuous glucose monitoring (CGM) is rapidly increasing. Standardized visual reporting and interpretation of CGM data and clear and understandable clinical targets will help professionals and individuals with diabetes use diabetes technology more efficiently, and finally improve long-term outcomes with less everyday disease burden. For the majority of people with type 1 or type 2 diabetes, time in range (between 70 and 180 mg/dL, or 3.9 and 10 mmol/L) target of more than 70% is recommended, with each incremental increase of 5% towards this target being clinically meaningful. At the same time, the goal is to minimize glycemic excursions: a recommended target for a time below range (< 70 mg/dL or < 3.9 mmol/L) is less than 4%, and time above range (> 180 mg/dL or 10 mmol/L) less than 25%, with less stringent goals for older individuals or those at increased risk. These targets should be individualized: the personal use of CGM with the standardized data presentation provides all necessary means to accurately tailor diabetes management to the needs of each individual with diabetes.
Collapse
Affiliation(s)
- Klemen Dovc
- University Children's Hospital, University Medical Center Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Tadej Battelino
- University Children's Hospital, University Medical Center Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
45
|
Setford S, Phillips S, Grady M. Evidence From a Long-Term, Systematic Post-Market Surveillance Program: Clinical Performance of a Hematocrit-Insensitive Blood Glucose Test Strip. J Diabetes Sci Technol 2021; 15:67-75. [PMID: 30730221 PMCID: PMC7783001 DOI: 10.1177/1932296819826968] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND Described is a manufacturer's systematic post-market evaluation of the long-term clinical accuracy of a commercially available blood glucose monitoring (BGM) test strip product. METHODS Production batches of test strips were routinely and regularly sampled and evaluated in a clinical setting to assess product accuracy. Evaluations were performed on capillary blood samples from a minimum of 100 subjects with diabetes, by clinical staff according to instructions for use. Readings were compared against capillary blood samples collected at the same time and measured by a standard laboratory reference method. Clinical accuracy was calculated according to EN ISO 15197:2015. RESULTS A total of 21 115 paired results were obtained, equating to 209 production batches over the >3-year period since test strip launch. Of the results, 97.6% met the accuracy criterion (range: 97.1-98.1% by year), with 98.1% of values presenting zero risk as defined by the surveillance error grid. At the <5th (21.0-33.8%) and >95th (48.3-59.4%) percentile extremes of hematocrit distribution, 97.9% and 96.4% of values were clinically accurate. The product also demonstrated clinical accuracy across all seven glucose ranges ("bins") as defined by the standard. Under conditions of combined hematocrit and glucose (<80 mg/dL and ≥300 mg/dL) extremes, 97.7% of values were clinically accurate. CONCLUSIONS Methodologies and results from a manufacturer's self-imposed clinical accuracy surveillance program of a BGM product is presented. Given the publication of sometimes-conflicting data presented within ad hoc BGM clinical accuracy evaluations, usually of limited size, it is advocated that BGM manufacturers adopt similarly robust and systematic surveillance programs to safeguard patients.
Collapse
Affiliation(s)
- Steven Setford
- LifeScan Scotland, Inverness, UK
- Steven Setford, PhD, LifeScan Scotland Ltd, Beechwood Park North, Inverness, IV2 3ED, UK.
| | | | | |
Collapse
|
46
|
Abstract
The American Diabetes Association (ADA) "Standards of Medical Care in Diabetes" includes the ADA's current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, a multidisciplinary expert committee (https://doi.org/10.2337/dc21-SPPC), are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA's clinical practice recommendations, please refer to the Standards of Care Introduction (https://doi.org/10.2337/dc21-SINT). Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Collapse
|
47
|
Shaw R, Stroo M, Fiander C, McMillan K. Selecting Mobile Health Technologies for Electronic Health Record Integration: Case Study. J Med Internet Res 2020; 22:e23314. [PMID: 33112248 PMCID: PMC7657715 DOI: 10.2196/23314] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 09/25/2020] [Accepted: 09/30/2020] [Indexed: 01/29/2023] Open
Abstract
Mobile health (mHealth) technologies, such as wearable devices and sensors that can be placed in the home, allow for the capture of physiologic, behavioral, and environmental data from patients between clinic visits. The inclusion of these data in the medical record may benefit patients and providers. Most health systems now have electronic health records (EHRs), and the ability to pull and send data to and from mobile devices via smartphones and other methods is increasing; however, many challenges exist in the evaluation and selection of devices to integrate to meet the needs of diverse patients with a range of clinical needs. We present a case report that describes a method that our health system uses, guided by a telehealth model to evaluate the selection of devices for EHR integration.
Collapse
Affiliation(s)
- Ryan Shaw
- Mobile App Gateway, Clinical & Translational Science Institute, Duke University, Durham, NC, United States.,School of Nursing, Duke University, Durham, NC, United States
| | - Marissa Stroo
- Mobile App Gateway, Clinical & Translational Science Institute, Duke University, Durham, NC, United States
| | - Christopher Fiander
- Duke Health Technology Solutions, Duke University Health System, Durham, NC, United States
| | - Katlyn McMillan
- Mobile App Gateway, Clinical & Translational Science Institute, Duke University, Durham, NC, United States.,Duke Health Technology Solutions, Duke University Health System, Durham, NC, United States
| |
Collapse
|
48
|
Song D, Hurley JC, Lia M. Estimated Treatment Effects of Tight Glycaemic Targets in Mild Gestational Diabetes Mellitus: A Multiple Cut-Off Regression Discontinuity Study Design. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:E7725. [PMID: 33105782 PMCID: PMC7660094 DOI: 10.3390/ijerph17217725] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 10/01/2020] [Accepted: 10/16/2020] [Indexed: 12/11/2022]
Abstract
Background: We investigated the treatment effects of tight glycaemic targets in a population universally screened according to the International Association of Diabetes and Pregnant Study Groups (IADPSG)/World Health Organisation (WHO) gestational diabetes mellitus (GDM) guidelines. As yet there, have been no randomized control trials evaluating the effectiveness of treatment of mild GDM diagnosed under the IADPSG/WHO diagnostic thresholds. We hypothesize that tight glycaemic control in pregnant women diagnosed with GDM will result in similar clinical outcomes to women just below the diagnostic thresholds. Methods: A multiple cut-off regression discontinuity study design in a retrospective observational cohort undergoing oral glucose tolerance tests (OGTT) (n = 1178). Treatment targets for women with GDM were: fasting capillary blood glucose (CBG) of ≤5.0 mmol/L and the 2-h post-prandial CBG of ≤6.7 mmol/L. Regression discontinuity study designs estimate treatment effects by comparing outcomes between a treated group to a counterfactual group just below the diagnostic thresholds with the assumption that covariates are similar. The counterfactual group was selected based on a composite score based on OGTT plasma glucose categories. Results: Women treated for GDM had lower rates of newborns large for gestational age (LGA), 4.6% versus those just below diagnostic thresholds 12.6%, relative risk 0.37 (95% CI, 0.16-0.85); and reduced caesarean section rates, 32.2% versus 43.0%, relative risk 0.75 (95% CI, 0.56-1.01). This was at the expense of increases in induced deliveries, 61.8% versus 39.3%, relative risk 1.57 (95% CI, 1.18-1.9); notations of neonatal hypoglycaemia, 15.8% versus 5.9%, relative risk 2.66 (95% CI, 1.23-5.73); and high insulin usage 61.1%. The subgroup analysis suggested that treatment of women with GDM with BMI ≥30 kg/m2 drove the reduction in caesarean section rates: 32.9% versus 55.9%, relative risk 0.59 (95%CI, 0.4-0.87). Linear regression interaction term effects between non-GDM and treated GDM were significant for LGA newborns (p = 0.001) and caesarean sections (p = 0.015). Conclusions: Tight glycaemic targets reduced rates of LGA newborns and caesarean sections compared to a counterfactual group just below the diagnostic thresholds albeit at the expense of increased rates of neonatal hypoglycaemia, induced deliveries, and high insulin usage.
Collapse
Affiliation(s)
- David Song
- Internal Medicine Service, Ballarat Base Hospital, Ballarat, Victoria 3350, Australia;
- Dorevitch Pathology, Chemical Pathology, Melbourne, Victoria 3084, Australia
- School of Medicine, Deakin University, Geelong, Victoria 3217, Australia
| | - James C Hurley
- Internal Medicine Service, Ballarat Base Hospital, Ballarat, Victoria 3350, Australia;
- Department of Rural Health|Melbourne Medical School, University of Melbourne, Ballarat, Victoria 3350, Australia
| | - Maryanne Lia
- Peninsula Health, Melbourne, Victoria 3199, Australia;
| |
Collapse
|
49
|
Yoo JH, Choi MS, Ahn J, Park SW, Kim Y, Hur KY, Jin SM, Kim G, Kim JH. Association Between Continuous Glucose Monitoring-Derived Time in Range, Other Core Metrics, and Albuminuria in Type 2 Diabetes. Diabetes Technol Ther 2020; 22:768-776. [PMID: 32167394 DOI: 10.1089/dia.2019.0499] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Background: As the use of continuous glucose monitoring (CGM) has increased, time in range (TIR) and other core CGM metrics are now emerging as the core metrics for clinical targets and assessing diabetic complications, beyond HbA1c. This study investigated the association between the CGM-derived TIR, hyperglycemia, hypoglycemia metrics, and albuminuria. Methods: A total of 866 subjects with type 2 diabetes who underwent 3 or 6 days of CGM and had urinary albumin-to-creatinine ratio (ACR) measurements were retrospectively reviewed. CGM metrics were defined according to the most recent international consensus. Albuminuria was defined as one or more of the ACR measurements being >30 mg/g. Results: The overall prevalence of albuminuria was 36.6%. The prevalence of albuminuria was lower in subjects who achieved the target of TIR 70-180 mg/dL, time above range (TAR) >180 mg/dL, and TAR >250 mg/dL, as recommended by international consensus (P < 0.001). Multiple logistic regression analysis revealed that the odds ratio of having albuminuria was 0.94 (95% confidence interval: 0.88-0.99, P for trend = 0.04) per 10% increase in TIR of 70-180 mg/dL, after adjusting for multiple factors, including glycemic variability. The results were similar for hyperglycemia metrics (TAR >250 mg/dL and TAR >180 mg/dL). Conclusions: TIR 70-180 mg/dL and hyperglycemia metrics are strongly associated with albuminuria in type 2 diabetes.
Collapse
Affiliation(s)
- Jee Hee Yoo
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
- Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Min Sun Choi
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Jiyeon Ahn
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Sung Woon Park
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Yejin Kim
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Kyu Yeon Hur
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Sang-Man Jin
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Gyuri Kim
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| | - Jae Hyeon Kim
- Division of Endocrinology and Metabolism, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
| |
Collapse
|
50
|
Osborn CY, Hirsch A, Sears LE, Heyman M, Raymond J, Huddleston B, Dachis J. One Drop App With an Activity Tracker for Adults With Type 1 Diabetes: Randomized Controlled Trial. JMIR Mhealth Uhealth 2020; 8:e16745. [PMID: 32540842 PMCID: PMC7530691 DOI: 10.2196/16745] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Revised: 01/24/2020] [Accepted: 06/13/2020] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND In 2017, mobile app support for managing diabetes was available to 64% of the global population of adults with diabetes. One Drop's digital therapeutics solution includes an evidence-based mobile app with global reach, a Bluetooth-connected glucometer, and in-app coaching from Certified Diabetes Educators. Among people with type 1 diabetes and an estimated hemoglobin A1c level≥7.5%, using One Drop for 3 months has been associated with an improved estimated hemoglobin A1c level of 22.2 mg/dL (-0.80%). However, the added value of integrated activity trackers is unknown. OBJECTIVE We conducted a pragmatic, remotely administered randomized controlled trial to evaluate One Drop with a new-to-market activity tracker against One Drop only on the 3-month hemoglobin A1c level of adults with type 1 diabetes. METHODS Social media advertisements and online newsletters were used to recruit adults (≥18 years old) diagnosed (≥1 year) with T1D, naïve to One Drop's full solution and the activity tracker, with a laboratory hemoglobin A1c level≥7%. Participants (N=99) were randomized to receive One Drop and the activity tracker or One Drop only at the start of the study. The One Drop only group received the activity tracker at the end of the study. Multiple imputation, performed separately by group, was used to correct for missing data. Analysis of covariance models, controlling for baseline hemoglobin A1c, were used to evaluate 3-month hemoglobin A1c differences in intent-to-treat (ITT) and per protocol (PP) analyses. RESULTS The enrolled sample (N=95) had a mean age of 41 (SD 11) years, was 73% female, 88% White, diagnosed for a mean of 20 (SD 11) years, and had a mean hemoglobin A1c level of 8.4% (SD 1.2%); 11% of the participants did not complete follow up. Analysis of covariance assumptions were met for the ITT and PP models. In ITT analysis, participants in the One Drop and activity tracker condition had a significantly lower 3-month hemoglobin A1c level (mean 7.9%, SD 0.60%, 95% CI 7.8-8.2) than that of the participants in the One Drop only condition (mean 8.4%, SD 0.62%, 95% CI 8.2-8.5). In PP analysis, participants in the One Drop and activity tracker condition also had a significantly lower 3-month hemoglobin A1c level (mean 7.9%, SD 0.59%, 95% CI 7.7-8.1) than that of participants in the One Drop only condition (mean 8.2%, SD 0.58%, 95% CI 8.0-8.4). CONCLUSIONS Participants exposed to One Drop and the activity tracker for the 3-month study period had a significantly lower 3-month hemoglobin A1c level compared to that of participants exposed to One Drop only during the same timeframe. One Drop and a tracker may work better together than alone in helping people with type 1 diabetes. TRIAL REGISTRATION ClinicalTrials.gov NCT03459573; https://clinicaltrials.gov/ct2/show/NCT03459573.
Collapse
Affiliation(s)
- Chandra Y Osborn
- Informed Data Systems Inc, New York, NY, United States.,Lirio, Nashville, TN, United States
| | - Ashley Hirsch
- Informed Data Systems Inc, New York, NY, United States
| | - Lindsay E Sears
- Informed Data Systems Inc, New York, NY, United States.,Sarah Cannon Research Institute, Nashville, TN, United States
| | - Mark Heyman
- Informed Data Systems Inc, New York, NY, United States.,Department of Psychiatry, University of California San Diego, San Diego, CA, United States
| | - Jennifer Raymond
- Division of Endocrinology, Department of Pediatrics, University of Southern California, Los Angeles, CA, United States
| | | | - Jeff Dachis
- Informed Data Systems Inc, New York, NY, United States
| |
Collapse
|