1
|
de Scals S, Fraile LM, Udías JM, Martínez Cortés L, Oteo M, Morcillo MÁ, Carreras-Delgado JL, Cabrera-Martín MN, España S. Feasibility study of a SiPM-fiber detector for non-invasive measurement of arterial input function for preclinical and clinical positron emission tomography. EJNMMI Phys 2024; 11:12. [PMID: 38291187 PMCID: PMC10828322 DOI: 10.1186/s40658-024-00618-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 01/19/2024] [Indexed: 02/01/2024] Open
Abstract
Pharmacokinetic positron emission tomography (PET) studies rely on the measurement of the arterial input function (AIF), which represents the time-activity curve of the radiotracer concentration in the blood plasma. Traditionally, obtaining the AIF requires invasive procedures, such as arterial catheterization, which can be challenging, time-consuming, and associated with potential risks. Therefore, the development of non-invasive techniques for AIF measurement is highly desirable. This study presents a detector for the non-invasive measurement of the AIF in PET studies. The detector is based on the combination of scintillation fibers and silicon photomultipliers (SiPMs) which leads to a very compact and rugged device. The feasibility of the detector was assessed through Monte Carlo simulations conducted on mouse tail and human wrist anatomies studying relevant parameters such as energy spectrum, detector efficiency and minimum detectable activity (MDA). The simulations involved the use of 18F and 68Ga isotopes, which exhibit significantly different positron ranges. In addition, several prototypes were built in order to study the different components of the detector including the scintillation fiber, the coating of the fiber, the SiPMs, and the operating configuration. Finally, the simulations were compared with experimental measurements conducted using a tube filled with both 18F and 68Ga to validate the obtained results. The MDA achieved for both anatomies (approximately 1000 kBq/mL for mice and 1 kBq/mL for humans) falls below the peak radiotracer concentrations typically found in PET studies, affirming the feasibility of conducting non-invasive AIF measurements with the fiber detector. The sensitivity for measurements with a tube filled with 18F (68Ga) was 1.2 (2.07) cps/(kBq/mL), while for simulations, it was 2.81 (6.23) cps/(kBq/mL). Further studies are needed to validate these results in pharmacokinetic PET studies.
Collapse
Affiliation(s)
- Sara de Scals
- Grupo de Física Nuclear, EMFTEL and IPARCOS, Universidad Complutense de Madrid, Madrid, Spain
- Instituto de Investigación del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Luis Mario Fraile
- Grupo de Física Nuclear, EMFTEL and IPARCOS, Universidad Complutense de Madrid, Madrid, Spain
- Instituto de Investigación del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - José Manuel Udías
- Grupo de Física Nuclear, EMFTEL and IPARCOS, Universidad Complutense de Madrid, Madrid, Spain
- Instituto de Investigación del Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| | - Laura Martínez Cortés
- Unidad de Aplicaciones Médicas de las Radiaciones Ionizantes, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | - Marta Oteo
- Unidad de Aplicaciones Médicas de las Radiaciones Ionizantes, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | - Miguel Ángel Morcillo
- Unidad de Aplicaciones Médicas de las Radiaciones Ionizantes, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT), Madrid, Spain
| | | | | | - Samuel España
- Grupo de Física Nuclear, EMFTEL and IPARCOS, Universidad Complutense de Madrid, Madrid, Spain.
- Instituto de Investigación del Hospital Clínico San Carlos (IdISSC), Madrid, Spain.
- Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain.
| |
Collapse
|
2
|
Nekolla SG, Rischpler C, Higuchi T. Preclinical Imaging of Cardiovascular Disesase. Semin Nucl Med 2023; 53:586-598. [PMID: 37268498 DOI: 10.1053/j.semnuclmed.2023.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 04/24/2023] [Accepted: 04/26/2023] [Indexed: 06/04/2023]
Abstract
Noninvasive imaging techniques, such as SPECT, PET, CT, echocardiography, or MRI, have become essential in cardiovascular research. They allow for the evaluation of biological processes in vivo without the need for invasive procedures. Nuclear imaging methods, such as SPECT and PET, offer numerous advantages, including high sensitivity, reliable quantification, and the potential for serial imaging. Modern SPECT and PET imaging systems, equipped with CT and MRI components in order to get access to morphological information with high spatial resolution, are capable of imaging a wide range of established and innovative agents in both preclinical and clinical settings. This review highlights the utility of SPECT and PET imaging as powerful tools for translational research in cardiology. By incorporating these techniques into a well-defined workflow- similar to those used in clinical imaging- the concept of "bench to bedside" can be effectively implemented.
Collapse
Affiliation(s)
- Stephan G Nekolla
- Nuklearmedizinische Klinik der TU München, Munich, Germany; DZHK (German Centre for Cardiovascular Research), partner site Munich Heart Alliance, Munich, Germany.
| | | | - Takahiro Higuchi
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany; Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
| |
Collapse
|
3
|
Sarrhini O, D'Orléans-Juste P, Rousseau JA, Beaudoin JF, Lecomte R. Enhanced Extraction of Blood and Tissue Time-Activity Curves in Cardiac Mouse FDG PET Imaging by Means of Constrained Nonnegative Matrix Factorization. Int J Biomed Imaging 2023; 2023:5366733. [PMID: 37362614 PMCID: PMC10287520 DOI: 10.1155/2023/5366733] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 05/16/2023] [Accepted: 05/20/2023] [Indexed: 06/28/2023] Open
Abstract
We propose an enhanced method to accurately retrieve time-activity curves (TACs) of blood and tissue from dynamic 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) positron emission tomography (PET) cardiac images of mice. The method is noninvasive and consists of using a constrained nonnegative matrix factorization algorithm (CNMF) applied to the matrix (A) containing the intensity values of the voxels of the left ventricle (LV) PET image. CNMF factorizes A into nonnegative matrices H and W, respectively, representing the physiological factors (blood and tissue) and their associated weights, by minimizing an extended cost function. We verified our method on 32 C57BL/6 mice, 14 of them with acute myocardial infarction (AMI). With CNMF, we could break down the mouse LV into myocardial and blood pool images. Their corresponding TACs were used in kinetic modeling to readily determine the [18F]FDG influx constant (Ki) required to compute the myocardial metabolic rate of glucose. The calculated Ki values using CNMF for the heart of control mice were in good agreement with those published in the literature. Significant differences in Ki values for the heart of control and AMI mice were found using CNMF. The values of the elements of W agreed well with the LV structural changes induced by ligation of the left coronary artery. CNMF was compared with the recently published method based on robust unmixing of dynamic sequences using regions of interest (RUDUR). A clear improvement of signal separation was observed with CNMF compared to the RUDUR method.
Collapse
Affiliation(s)
- Otman Sarrhini
- Sherbrooke Molecular Imaging Center, Research Center of the Sherbrooke University Hospital (CRCHUS), Sherbrooke, QC, Canada
| | - Pedro D'Orléans-Juste
- Department of Pharmacology-Physiology, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| | - Jacques A. Rousseau
- Sherbrooke Molecular Imaging Center, Research Center of the Sherbrooke University Hospital (CRCHUS), Sherbrooke, QC, Canada
| | - Jean-François Beaudoin
- Sherbrooke Molecular Imaging Center, Research Center of the Sherbrooke University Hospital (CRCHUS), Sherbrooke, QC, Canada
| | - Roger Lecomte
- Sherbrooke Molecular Imaging Center, Research Center of the Sherbrooke University Hospital (CRCHUS), Sherbrooke, QC, Canada
- Department of Nuclear Medicine and Radiobiology, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada
| |
Collapse
|
4
|
Fang YHD, McConathy JE, Yacoubian TA, Zhang Y, Kennedy RE, Standaert DG. Image Quantification for TSPO PET with a Novel Image-Derived Input Function Method. Diagnostics (Basel) 2022; 12:1161. [PMID: 35626315 PMCID: PMC9140104 DOI: 10.3390/diagnostics12051161] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/02/2022] [Accepted: 05/03/2022] [Indexed: 01/27/2023] Open
Abstract
There is a growing interest in using 18F-DPA-714 PET to study neuroinflammation and microglial activation through imaging the 18-kDa translocator protein (TSPO). Although quantification of 18F-DPA-714 binding can be achieved through kinetic modeling analysis with an arterial input function (AIF) measured with blood sampling procedures, the invasiveness of such procedures has been an obstacle for wide application. To address these challenges, we developed an image-derived input function (IDIF) that noninvasively estimates the arterial input function from the images acquired for 18F-DPA-714 quantification. Methods: The method entails three fully automatic steps to extract the IDIF, including a segmentation of voxels with highest likelihood of being the arterial blood over the carotid artery, a model-based matrix factorization to extract the arterial blood signal, and a scaling optimization procedure to scale the extracted arterial blood signal into the activity concentration unit. Two cohorts of human subjects were used to evaluate the extracted IDIF. In the first cohort of five subjects, arterial blood sampling was performed, and the calculated IDIF was validated against the measured AIF through the comparison of distribution volumes from AIF (VT,AIF) and IDIF (VT,IDIF). In the second cohort, PET studies from twenty-eight healthy controls without arterial blood sampling were used to compare VT,IDIF with VT,REF measured using a reference region-based analysis to evaluate whether it can distinguish high-affinity (HAB) and mixed-affinity (MAB) binders. Results: In the arterial blood-sampling cohort, VT derived from IDIF was found to be an accurate surrogate of the VT from AIF. The bias of VT, IDIF was −5.8 ± 7.8% when compared to VT,AIF, and the linear mixed effect model showed a high correlation between VT,AIF and VT, IDIF (p < 0.001). In the nonblood-sampling cohort, VT, IDIF showed a significance difference between the HAB and MAB healthy controls. VT, IDIF and standard uptake values (SUV) showed superior results in distinguishing HAB from MAB subjects than VT,REF. Conclusions: A novel IDIF method for 18F-DPA-714 PET quantification was developed and evaluated in this study. This IDIF provides a noninvasive alternative measurement of VT to quantify the TSPO binding of 18F-DPA-714 in the human brain through dynamic PET scans.
Collapse
Affiliation(s)
- Yu-Hua Dean Fang
- Department of Radiology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA;
- Center for Neurodegeneration and Experimental Therapeutics, Department of Neurology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA; (T.A.Y.); (D.G.S.)
| | - Jonathan E. McConathy
- Department of Radiology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA;
| | - Talene A. Yacoubian
- Center for Neurodegeneration and Experimental Therapeutics, Department of Neurology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA; (T.A.Y.); (D.G.S.)
| | - Yue Zhang
- Department of Medicine, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA; (Y.Z.); (R.E.K.)
| | - Richard E. Kennedy
- Department of Medicine, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA; (Y.Z.); (R.E.K.)
| | - David G. Standaert
- Center for Neurodegeneration and Experimental Therapeutics, Department of Neurology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, AL 35294, USA; (T.A.Y.); (D.G.S.)
| |
Collapse
|
5
|
Vrachliotis A, Kastis GA, Protonotarios NE, Fokas AS, Nekolla SG, Anagnostopoulos CD, Costaridou L, Gaitanis A. Evaluation of the spline reconstruction technique for preclinical PET imaging. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 217:106668. [PMID: 35176596 DOI: 10.1016/j.cmpb.2022.106668] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 12/27/2021] [Accepted: 01/26/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE The Spline Reconstruction Technique (SRT) is a fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The purpose of this study is to provide a comparison between SRT, Filtered Back-Projection (FBP), Ordered Subset Expectation Maximization 2D (2D-OSEM), and the Tera-Tomo 3D algorithm, using phantom data at various acquisition durations as well as small-animal data obtained from the Mediso nanoScan® PET/CT scanner. METHODS For this purpose, the "NEMA NU 4-2008 standards" protocol was employed at five different realizations and acquisition durations. In addition to the image quality metrics described by the NEMA protocol, Cold Region Contrast was also considered as a figure-of-merit. Furthermore, Cold Region Contrast was measured in the myocardial infarction region of six male Wistar rats. The volumetric defect quantification was assessed with dedicated computer software. Lastly, plots of Recovery Coefficient and Spill-Over Ratio as a function of the Percentage Standard Deviation were generated, after smoothing the phantom reconstructions with four different Gaussian filters. Statistical significance was determined by employing the Kruskal-Wallis test or One-way Analysis of Variance depending on the normality of the variable's distribution. RESULTS The present study revealed that, at the expense of slightly increased noise in the reconstructed images, SRT resulted in higher Recovery Coefficient values for small hot regions of interest, when compared with FBP and 2D-OSEM at all acquisition durations. Furthermore, SRT reconstructed images exhibit higher Recovery Coefficient values, for all hot regions of interest, when compared to the other 2D algorithms at short acquisition durations. In both phantom and animal studies, SRT achieved a significant improvement over 2D-OSEM for the Spill-Over Ratio and the Cold Region Contrast. These advantages were maintained even after comparing the algorithms at equal noise levels. The Tera-Tomo 3D algorithm (4 subsets, iterations≥ 13) performed significantly better compared to the other algorithms for all figures-of-merit. No statistically significant differences regarding the myocardial defect size were observed between the algorithms investigated. CONCLUSIONS Overall, SRT appears that could be useful for the quantification of small hot regions of interest, cold regions of interest, as well as in low-count imaging applications.
Collapse
Affiliation(s)
- Alexandros Vrachliotis
- Department of Medical Physics, School of Medicine, University of Patras, Patras 26504, Greece; Clinical, Experimental Surgery and Translational Research, Biomedical Research Foundation, Academy of Athens (BRFAA), Athens 11527, Greece
| | - George A Kastis
- Mathematics Research Center, Academy of Athens, Athens 11527, Greece; Institute of Nuclear & Radiological Sciences & Technology, Energy & Safety, National Center for Scientific Research "Demokritos", 15341 Athens, Greece
| | - Nicholas E Protonotarios
- Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB30WA, United Kingdom
| | - Athanasios S Fokas
- Mathematics Research Center, Academy of Athens, Athens 11527, Greece; Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Cambridge CB30WA, United Kingdom
| | - Stephan G Nekolla
- Klinikum rechts der Isar, Department of Nuclear Medicine and DZHK (German Centre for Cardiovascular Research), Technical University Munich, Partner Site Munich Heart Alliance, Munich 80336, Germany
| | - Constantinos D Anagnostopoulos
- Clinical, Experimental Surgery and Translational Research, Biomedical Research Foundation, Academy of Athens (BRFAA), Athens 11527, Greece
| | - Lena Costaridou
- Department of Medical Physics, School of Medicine, University of Patras, Patras 26504, Greece
| | - Anastasios Gaitanis
- Clinical, Experimental Surgery and Translational Research, Biomedical Research Foundation, Academy of Athens (BRFAA), Athens 11527, Greece.
| |
Collapse
|
6
|
Ren W, Ji B, Guan Y, Cao L, Ni R. Recent Technical Advances in Accelerating the Clinical Translation of Small Animal Brain Imaging: Hybrid Imaging, Deep Learning, and Transcriptomics. Front Med (Lausanne) 2022; 9:771982. [PMID: 35402436 PMCID: PMC8987112 DOI: 10.3389/fmed.2022.771982] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Accepted: 02/16/2022] [Indexed: 12/26/2022] Open
Abstract
Small animal models play a fundamental role in brain research by deepening the understanding of the physiological functions and mechanisms underlying brain disorders and are thus essential in the development of therapeutic and diagnostic imaging tracers targeting the central nervous system. Advances in structural, functional, and molecular imaging using MRI, PET, fluorescence imaging, and optoacoustic imaging have enabled the interrogation of the rodent brain across a large temporal and spatial resolution scale in a non-invasively manner. However, there are still several major gaps in translating from preclinical brain imaging to the clinical setting. The hindering factors include the following: (1) intrinsic differences between biological species regarding brain size, cell type, protein expression level, and metabolism level and (2) imaging technical barriers regarding the interpretation of image contrast and limited spatiotemporal resolution. To mitigate these factors, single-cell transcriptomics and measures to identify the cellular source of PET tracers have been developed. Meanwhile, hybrid imaging techniques that provide highly complementary anatomical and molecular information are emerging. Furthermore, deep learning-based image analysis has been developed to enhance the quantification and optimization of the imaging protocol. In this mini-review, we summarize the recent developments in small animal neuroimaging toward improved translational power, with a focus on technical improvement including hybrid imaging, data processing, transcriptomics, awake animal imaging, and on-chip pharmacokinetics. We also discuss outstanding challenges in standardization and considerations toward increasing translational power and propose future outlooks.
Collapse
Affiliation(s)
- Wuwei Ren
- School of Information Science and Technology, ShanghaiTech University, Shanghai, China
- Shanghai Engineering Research Center of Energy Efficient and Custom AI IC, Shanghai, China
| | - Bin Ji
- Department of Radiopharmacy and Molecular Imaging, School of Pharmacy, Fudan University, Shanghai, China
| | - Yihui Guan
- PET Center, Huashan Hospital, Fudan University, Shanghai, China
| | - Lei Cao
- Shanghai Changes Tech, Ltd., Shanghai, China
| | - Ruiqing Ni
- Institute for Regenerative Medicine, University of Zurich, Zurich, Switzerland
- Institute for Biomedical Engineering, ETH Zürich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
7
|
Convert L, Sarrhini O, Paillé M, Salem N, Charette PG, Lecomte R. The ultra high sensitivity blood counter: a compact, MRI-compatible, radioactivity counter for pharmacokinetic studies in µL volumes. Biomed Phys Eng Express 2022; 8. [PMID: 35038694 DOI: 10.1088/2057-1976/ac4c29] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Accepted: 01/17/2022] [Indexed: 11/11/2022]
Abstract
Quantification of physiological parameters in preclinical pharmacokinetic studies based on nuclear imaging requires the monitoring of arterial radioactivity over time, known as the arterial input function (AIF). Continuous derivation of the AIF in rodent models is very challenging because of the limited blood volume available for sampling. To address this challenge, an Ultra High Sensitivity Blood Counter (UHS-BC) was developed. The device detects beta particles in real-time using silicon photodiodes, custom low-noise electronics, and 3D-printed plastic cartridges to hold standard catheters. Two prototypes were built and characterized in two facilities. Sensitivities up to 39% for18F and 58% for11C-based positron emission tomography (PET) tracers were demonstrated.99mTc and125I based Single Photon Emission Computed Tomography (SPECT) tracers were detected with greater than 3% and 10% sensitivity, respectively, opening new applications in nuclear imaging and fundamental biology research. Measured energy spectra show all relevant peaks down to a minimum detectable energy of 20 keV. The UHS-BC was shown to be highly reliable, robust towards parasitic background radiation and electromagnetic interference in the PET or MRI environment. The UHS-BC provides reproducible results under various experimental conditions and was demonstrated to be stable over days of continuous operation. Animal experiments showed that the UHS-BC performs accurate AIF measurements using low detection volumes suitable for small animal models in PET, SPECT and PET/MRI investigations. This tool will help to reduce the time and number of animals required for pharmacokinetic studies, thus increasing the throughput of new drug development.
Collapse
Affiliation(s)
- Laurence Convert
- Institut Interdisciplinaire d'Innovation Technologique (3IT), Université de Sherbrooke, 3000 boul. de l'Université, Parc Innovation, Pavillon P2, Sherbrooke, Sherbrooke, Quebec, J1K0A5, CANADA
| | - Otman Sarrhini
- Sherbrooke Molecular Imaging Centre of CRCHUS and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 3001 12 ave Nord, Sherbrooke, Quebec, J1H 5N4, CANADA
| | - Maxime Paillé
- Sherbrooke Molecular Imaging Centre of CRCHUS and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 3001 12 Ave Nord, Sherbrooke, Quebec, J1H 5N4, CANADA
| | - Nicolas Salem
- Biogen Idec Inc, 225 Binney St, Cambridge, Massachusetts, 02142, UNITED STATES
| | - Paul Gilles Charette
- Laboratoire Nanotechnologies Nanosystèmes (LN2) - CNRS UMI-3463, Université de Sherbrooke, 3000 boul. de l'Université, Parc Innovation, Pavillon P2, Sherbrooke, Quebec, J1K 0A5, CANADA
| | - Roger Lecomte
- Sherbrooke Molecular Imaging Centre of CRCHUS and Department of Nuclear Medicine and Radiobiology, Universite de Sherbrooke, 3001 12 Ave Nord, Sherbrooke, Quebec, J1K 2R1, CANADA
| |
Collapse
|
8
|
Massey JC, Seshadri V, Paul S, Mińczuk K, Molinos C, Li J, Kundu BK. Model Corrected Blood Input Function to Compute Cerebral FDG Uptake Rates From Dynamic Total-Body PET Images of Rats in vivo. Front Med (Lausanne) 2021; 8:618645. [PMID: 33898476 PMCID: PMC8058193 DOI: 10.3389/fmed.2021.618645] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 02/15/2021] [Indexed: 12/17/2022] Open
Abstract
Recently, we developed a three-compartment dual-output model that incorporates spillover (SP) and partial volume (PV) corrections to simultaneously estimate the kinetic parameters and model-corrected blood input function (MCIF) from dynamic 2-[18F] fluoro-2-deoxy-D-glucose positron emission tomography (FDG PET) images of mouse heart in vivo. In this study, we further optimized this model and utilized the estimated MCIF to compute cerebral FDG uptake rates, Ki, from dynamic total-body FDG PET images of control Wistar–Kyoto (WKY) rats and compared to those derived from arterial blood sampling in vivo. Dynamic FDG PET scans of WKY rats (n = 5), fasted for 6 h, were performed using the Albira Si Trimodal PET/SPECT/CT imager for 60 min. Arterial blood samples were collected for the entire imaging duration and then fitted to a seven-parameter function. The 60-min list mode PET data, corrected for attenuation, scatter, randoms, and decay, were reconstructed into 23 time bins. A 15-parameter dual-output model with SP and PV corrections was optimized with two cost functions to compute MCIF. A four-parameter compartment model was then used to compute cerebral Ki. The computed area under the curve (AUC) and Ki were compared to that derived from arterial blood samples. Experimental and computed AUCs were 1,893.53 ± 195.39 kBq min/cc and 1,792.65 ± 155.84 kBq min/cc, respectively (p = 0.76). Bland–Altman analysis of experimental vs. computed Ki for 35 cerebral regions in WKY rats revealed a mean difference of 0.0029 min−1 (~13.5%). Direct (AUC) and indirect (Ki) comparisons of model computations with arterial blood sampling were performed in WKY rats. AUC and the downstream cerebral FDG uptake rates compared well with that obtained using arterial blood samples. Experimental vs. computed cerebral Ki for the four super regions including cerebellum, frontal cortex, hippocampus, and striatum indicated no significant differences.
Collapse
Affiliation(s)
- James C Massey
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States
| | - Vikram Seshadri
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States
| | - Soumen Paul
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States
| | - Krzysztof Mińczuk
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.,Department of Experimental Physiology and Pathophysiology, Medical University of Białystok, Białystok, Poland
| | - Cesar Molinos
- Preclinical Imaging Division, Bruker Biospin, Billerica, MA, United States
| | - Jie Li
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States
| | - Bijoy K Kundu
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.,Department of Biomedical Engineering, University of Virginia, Charlottesville, VA, United States.,Cardiovascular Research Center, University of Virginia, Charlottesville, VA, United States
| |
Collapse
|
9
|
Corrado PA, Barton GP, Razalan-Krause FC, François CJ, Chesler NC, Wieben O, Eldridge M, McMillan AB, Goss KN. Dynamic FDG PET Imaging to Probe for Cardiac Metabolic Remodeling in Adults Born Premature. J Clin Med 2021; 10:1301. [PMID: 33809883 PMCID: PMC8004130 DOI: 10.3390/jcm10061301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/17/2021] [Accepted: 03/19/2021] [Indexed: 11/20/2022] Open
Abstract
Individuals born very premature have an increased cardiometabolic and heart failure risk. While the structural differences of the preterm heart are now well-described, metabolic insights into the physiologic mechanisms underpinning this risk are needed. Here, we used dynamic fluorodeoxyglucose (FDG) positron emission tomography/magnetic resonance imaging (PET-MRI) in young adults born term and preterm during normoxic (N = 28 preterm; 18 term) and hypoxic exposure (12% O2; N = 26 preterm; 17 term) to measure the myocardial metabolic rate of glucose (MMRglc) in young adults born term (N = 18) and preterm (N = 32), hypothesizing that young adults born preterm would have higher rates of MMRglc under normoxic conditions and a reduced ability to augment glucose metabolism under hypoxic conditions. MMRglc was calculated from the myocardial and blood pool time-activity curves by fitting the measured activities to the 3-compartment model of FDG kinetics. MMRglc was similar at rest between term and preterm subjects, and decreased during hypoxia exposure in both groups (p = 0.02 for MMRglc hypoxia effect). There were no differences observed between groups in the metabolic response to hypoxia, either globally (serum glucose and lactate measures) or within the myocardium. Thus, we did not find evidence of altered myocardial metabolism in the otherwise healthy preterm-born adult. However, whether subtle changes in myocardial metabolism may preceed or predict heart failure in this population remains to be determined.
Collapse
Affiliation(s)
- Philip A. Corrado
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA; (P.A.C.); (G.P.B.); (O.W.); (A.B.M.)
| | - Gregory P. Barton
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA; (P.A.C.); (G.P.B.); (O.W.); (A.B.M.)
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- Department of Pediatrics, University of Wisconsin-Madison, Madison, WI 53705, USA;
| | | | | | - Naomi C. Chesler
- Edwards Lifesciences Center for Advanced Cardiovascular Technology, University of California, Irvine, CA 92697, USA;
- Department of Biomedical Engineering, University of California, Irvine, CA 92697, USA
| | - Oliver Wieben
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA; (P.A.C.); (G.P.B.); (O.W.); (A.B.M.)
- Department of Radiology, University of Wisconsin-Madison, Madison, WI 53705, USA;
| | - Marlowe Eldridge
- Department of Pediatrics, University of Wisconsin-Madison, Madison, WI 53705, USA;
- Department of Medicine, University of Wisconsin-Madison, Madison, WI 53705, USA;
| | - Alan B. McMillan
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, USA; (P.A.C.); (G.P.B.); (O.W.); (A.B.M.)
- Department of Radiology, University of Wisconsin-Madison, Madison, WI 53705, USA;
| | - Kara N. Goss
- Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
- Department of Pediatrics, University of Wisconsin-Madison, Madison, WI 53705, USA;
- Department of Medicine, University of Wisconsin-Madison, Madison, WI 53705, USA;
| |
Collapse
|
10
|
Abstract
Positron emission tomography (PET) is a non-invasive imaging technology employed to describe metabolic, physiological, and biochemical processes in vivo. These include receptor availability, metabolic changes, neurotransmitter release, and alterations of gene expression in the brain. Since the introduction of dedicated small-animal PET systems along with the development of many novel PET imaging probes, the number of PET studies using rats and mice in basic biomedical research tremendously increased over the last decade. This article reviews challenges and advances of quantitative rodent brain imaging to make the readers aware of its physical limitations, as well as to inspire them for its potential applications in preclinical research. In the first section, we briefly discuss the limitations of small-animal PET systems in terms of spatial resolution and sensitivity and point to possible improvements in detector development. In addition, different acquisition and post-processing methods used in rodent PET studies are summarized. We further discuss factors influencing the test-retest variability in small-animal PET studies, e.g., different receptor quantification methodologies which have been mainly translated from human to rodent receptor studies to determine the binding potential and changes of receptor availability and radioligand affinity. We further review different kinetic modeling approaches to obtain quantitative binding data in rodents and PET studies focusing on the quantification of endogenous neurotransmitter release using pharmacological interventions. While several studies have focused on the dopamine system due to the availability of several PET tracers which are sensitive to dopamine release, other neurotransmitter systems have become more and more into focus and are described in this review, as well. We further provide an overview of latest genome engineering technologies, including the CRISPR/Cas9 and DREADD systems that may advance our understanding of brain disorders and function and how imaging has been successfully applied to animal models of human brain disorders. Finally, we review the strengths and opportunities of simultaneous PET/magnetic resonance imaging systems to study drug-receptor interactions and challenges for the translation of PET results from bench to bedside.
Collapse
|
11
|
Feasibility of Longitudinal Brain PET with Real-Time Arterial Input Function in Rats. Mol Imaging Biol 2020; 23:350-360. [PMID: 33201350 DOI: 10.1007/s11307-020-01556-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 09/18/2020] [Accepted: 10/13/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Preclinical dynamic brain PET studies remain hampered by the limitations related to the measurement of the arterial input function (AIF). In this regard, the use of an arterial-venous shunt is a promising method for the generation of real-time AIFs, but its application in longitudinal studies is still impeded by the cumbersome surgeries and high failure rates. We studied the feasibility and reproducibility of double arterial-venous shunt strategies for conducting longitudinal PET studies with real-time AIFs in rats. PROCEDURES We studied the feasibility of double arterial-venous shunts in rats in the right/left inguinal region and evaluated inter-animal and intra-animal AIF reproducibilities. Image-derived input function (IDIF) was also obtained for comparison. Dynamic brain FDG PET studies were conducted to estimate kinetic constants and Cerebral Metabolic Rate of Glucose (CMRglc) obtained from standard 2-tissue compartment (2TCM) and Patlak analysis. RESULTS We showed that longitudinal AIFs from double arterial-venous shunts can be obtained with very high success rate of the surgeries (88 %). Our results provided highly reproducible AIF measurements with low inter-animal variabilities (11 %) and intra-animal variabilities (5-10 %) that were included into the kinetic models, such that longitudinal rate constants and CMRglc can be efficiently estimated without bias associated to the double shunt. Our results indicated that longitudinal IDIF can be also generated without bias along time but showing higher intra-animal uncertainties. CONCLUSIONS We have demonstrated the feasibility and high reproducibility of conducting longitudinal AIF measurements and consequently accurate kinetic modeling using arterial shunt method.
Collapse
|
12
|
Huang HM. Kernel-based curve-fitting method with spatial regularization for generation of parametric images in dynamic PET. Phys Med Biol 2020; 65:225006. [PMID: 33200750 DOI: 10.1088/1361-6560/abb1d8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Due to high levels of noise in pixel-wise time-activity curves, the indirect method that generates kinetic parametric images from dynamic positron emission tomography (PET) images often results in poor parametric image quality. We have demonstrated that the quality of parametric images can be improved by denoising dynamic PET images, using gradient-free curve-fitting and applying a kernel-based post-filtering to parametric images. However, many gradient-free curve-fitting methods are time-consuming. Moreover, some parameter estimates (e.g. k2 and k3) have large variability. To provide high-quality PET parametric images with low computational cost, we propose a curve-fitting method that incorporates the kernel-based denoising method and the highly constrained backprojection technique into the Levenberg-Marquardt (LM) algorithm. We conducted a simulation study to evaluate the performance of the proposed curve-fitting method. Dynamic PET images were reconstructed using the expectation-maximization (EM) algorithm and were denoised before parameter estimation. Compared to the LM algorithm with and without the kernel-based post-filtering, the proposed method achieved superior performance, offering a decrease in both bias and coefficient of variation (CV) on all parametric images. Overall, the proposed method exhibited lower bias and slightly higher CV than the gradient-free pattern search method with the kernel-based post-filtering (PatS-K). Moreover, the computation time of the proposed method was about 18 times lower than that of the PatS-K method. Finally, we show that the proposed method can further improve the quality of parametric images when dynamic PET images are reconstructed using the kernel-based EM algorithm.
Collapse
Affiliation(s)
- Hsuan-Ming Huang
- Institute of Medical Device and Imaging, College of Medicine, National Taiwan University, No.1, Sec. 1, Jen Ai Rd., Zhongzheng Dist., Taipei City 100, Taiwan
| |
Collapse
|
13
|
Assessment of late-term progression of cardiac allograft vasculopathy in patients with orthotopic heart transplantation using quantitative cardiac 82Rb PET. Int J Cardiovasc Imaging 2020; 37:1461-1472. [PMID: 33123937 DOI: 10.1007/s10554-020-02086-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 10/23/2020] [Indexed: 10/23/2022]
Abstract
The risk stratification and long-term survival of patients with orthotopic heart transplantation (OHT) is impacted by the complication of cardiac allograft vasculopathy (CAV). This study evaluates changes in myocardial blood flow (MBF) and myocardial coronary flow reserve (CFR) in a group of long-term OHT patients using quantitative cardiac 82Rb-positron emission tomography (PET). Twenty patients (7 females and 13 males, mean age = 72.7 ± 12.2 years with CAV and 62.9 ± 7.2 years without CAV and post-OHT mean time = 13.9 years), were evaluated retrospectively using dynamic cardiac 82Rb-PET at rest and regadenoson-induced stress. The patients also underwent selective coronary angiography (SCA) for diagnosis and risk stratification. CAV was diagnosed based on SCA findings and maximal intimal thickness greater than 0.5 mm, as defined by International Society of Heart and Lung Transplantation (ISHLT). Global and regional MBFs were estimated in three vascular territories using the standard 1-tissue compartment model for dynamic 82Rb-PET. The myocardial CFR was also calculated as the ratio of peak stress MBF to rest MBF. Among twenty patients, seven had CAV in, at least, one major coronary artery (ISHLT CAV grade 1 or higher) while 13 patients did not have CAV (NonCAV). Mean rate-pressure products (RPP) at rest were significantly elevated in CAV patients compared to those without CAV (P = 0.002) but it was insignificant at stress (P = NS). There was no significant difference in the stress MBFs between CAV and NonCAV patients (P = NS). However, the difference in RPP-normalized stress MBFs was significant (P = 0.045), while RPP-normalized MBFs at rest was not significant (P = NS). Both CFR and RPP-normalized CFR were significantly lower in CAV compared to NonCAV patients (P < 0.001). There were significant correlations between MBFs and RPPs at rest for both CAV (ρ = 0.764, P = 0.047) and NonCAV patients (ρ = 0.641, P = 0.017), while there were no correlations at stress for CAV (ρ = 0.232, P = NS) and NonCAV patients (ρ = 0.068, P = NS). This study indicates that the resting MBF is higher in late-term post-OHT patients. The high resting MBF and reduced CFR suggest an unprecedented demand of blood flow and blunted response to stress due to impaired vasodilatory capacity that is exacerbated by the presence of CAV.
Collapse
|
14
|
Valic MS, Halim M, Schimmer P, Zheng G. Guidelines for the experimental design of pharmacokinetic studies with nanomaterials in preclinical animal models. J Control Release 2020; 323:83-101. [PMID: 32278829 DOI: 10.1016/j.jconrel.2020.04.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 03/24/2020] [Accepted: 04/01/2020] [Indexed: 12/14/2022]
Abstract
A shared feature in the value proposition of every nanomaterial-based drug delivery systems is the desirable improvement in the disposition (or ADME) and pharmacokinetic profiles of the encapsulated drug being delivered. Remarkable progress has been made towards understanding the complex and multifactorial relationships between pharmacokinetic profiles and nanomaterial physicochemical properties, biological interactions, species physiology, etc. These advances have fuelled the rational design of numerous nanomaterials with long-circulation times and improved tissue accumulation (e.g., in tumours). Unfortunately, a central weakness in many of these research efforts has been the inconsistent and insufficient characterisation of the pharmacokinetic profiles of nanomaterials in scientific reporting-a problem affecting the majoirty of of contemporary nanomaterials literature and innovative nanomaterials in early stages of preclinical development especially. Given the significant role of pharmacokinetic assessments to serve as guideposts for deciding whether to continue with the preclinical development and clinical translation of drug delivery systems, the prevalence of poor pharmacokinetic characterisations in nanomaterials research is particularly alarming. A conspicuous problem in many reports is the inappropriate selection of experimental designs and methodologies for studying nanomaterial pharmacokinetics, the consequences of which are increased uncertainty over the accurate interpretation of reported pharmacokinetic data and diminished experimental reproducibility throughout the field. Thus, there is renewed interest in the establishment of consistent and comprehensive strategies for designing preclinical experiments to assess the pharmacokinetics of nanomaterials with diverse physicochemical properties. Towards this end, herein are proposed simple guidelines for the experimental design of pharmacokinetic studies with nanomaterials drawn from the best research practices, principle strategies, and important considerations used in industry for collecting pharmacokinetic data in preclinical animal models. Specifically, key experimental design factors in these studies are identified and examined in the context of nanomaterials for optimality, including blood sampling strategy and technique, sample allocation and sampling time window, test species selection, experimental sources of pharmacokinetic variability, etc. Methods for noninvasive imaging-derived pharmacokinetic assessments of theranostic nanomaterials are also explored with particular focus on emission tomography imaging modalities. Taken together, this review will provide nanomaterial researchers with practical knowledge and pragmatic recommendations for selecting the best designs and methodologies for assessing the pharmacokinetic profiles of their nanomaterials, and hopefully maximise the chances of translational success of these innovative products into humans.
Collapse
Affiliation(s)
- Michael S Valic
- Princess Margaret Cancer Centre, University Health Network, Princess Margaret Cancer Research Tower, 101 College Street, Room 5-354, Toronto, Ontario M5G 1L7, Canada
| | - Michael Halim
- Princess Margaret Cancer Centre, University Health Network, Princess Margaret Cancer Research Tower, 101 College Street, Room 5-354, Toronto, Ontario M5G 1L7, Canada
| | - Pamela Schimmer
- Princess Margaret Cancer Centre, University Health Network, Princess Margaret Cancer Research Tower, 101 College Street, Room 5-354, Toronto, Ontario M5G 1L7, Canada
| | - Gang Zheng
- Princess Margaret Cancer Centre, University Health Network, Princess Margaret Cancer Research Tower, 101 College Street, Room 5-354, Toronto, Ontario M5G 1L7, Canada; Department of Medical Biophysics, University of Toronto, Princess Margaret Cancer Research Tower, Room 15-701, Toronto, Ontario M5G 1L7, Canada.
| |
Collapse
|
15
|
He X, Wedekind F, Kroll T, Oskamp A, Beer S, Drzezga A, Ermert J, Neumaier B, Bauer A, Elmenhorst D. Image-Derived Input Functions for Quantification of A 1 Adenosine Receptors Availability in Mice Brains Using PET and [ 18F]CPFPX. Front Physiol 2020; 10:1617. [PMID: 32063864 PMCID: PMC7000659 DOI: 10.3389/fphys.2019.01617] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 12/23/2019] [Indexed: 12/28/2022] Open
Abstract
Purpose In vivo imaging for the A1 adenosine receptors (A1ARs) with positron emission tomography (PET) using 8-cyclopentyl-3-(3-[18F]fluoropropyl)-1-propylxan- thine ([18F]CPFPX) has become an important tool for studying physiological processes quantitatively in mice. However, the measurement of arterial input functions (AIFs) on mice is a method with restricted applicability because of the small total blood volume and the related difficulties in withdrawing blood. Therefore, the aim of this study was to extract an appropriate [18F]CPFPX image-derived input function (IDIF) from dynamic PET images of mice. Procedures In this study, five mice were scanned with [18F]CPFPX for 60 min. Arterial blood samples (n = 7 per animal) were collected from the femoral artery and corrected for metabolites. To generate IDIFs, three different approaches were selected: (A) volume of interest (VOI) placed over the heart (cube, 10 mm); (B) VOI set over abdominal vena cava/aorta region with a cuboid (5 × 5 × 15 mm); and (C) with 1 × 1 × 1 mm voxels on five consecutive slices. A calculated scaling factor (α) was used to correct for partial volume effect; the method of obtaining the total metabolite correction of [18F]CPFPX for IDIFs was developed. Three IDIFs were validated by comparison with AIF. Validation included the following: visual performance; computing area under the curve (AUC) ratios (IDIF/AIF) of whole-blood curves and parent curves; and the mean distribution volume (VT) ratios (IDIF/AIF) of A1ARs calculated by Logan plot and two-tissue compartment model. Results Compared with the AIF, the IDIF with VOI over heart showed the best performance among the three IDIFs after scaling by 1.77 (α) in terms of visual analysis, AUC ratios (IDIF/AIF; whole-blood AUC ratio, 1.03 ± 0.06; parent curve AUC ratio, 1.01 ± 0.10) and VT ratios (IDIF/AIF; Logan VT ratio, 1.00 ± 0.17; two-tissue compartment model VT ratio, 1.00 ± 0.13) evaluation. The A1ARs distribution of average parametric images was in good accordance to autoradiography of the mouse brain. Conclusion The proposed study provides evidence that IDIF with VOI over heart can replace AIF effectively for quantification of A1ARs using PET and [18F]CPFPX in mice brains.
Collapse
Affiliation(s)
- Xuan He
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany.,Department of Neurophysiology, Institute of Zoology (Bio-II), RWTH Aachen University, Aachen, Germany
| | - Franziska Wedekind
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany
| | - Tina Kroll
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany
| | - Angela Oskamp
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany
| | - Simone Beer
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany
| | - Alexander Drzezga
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany.,Department of Nuclear Medicine, University Hospital of Cologne, Cologne, Germany
| | - Johannes Ermert
- Institut für Neurowissenschaften und Medizin (INM-5), Forschungszentrum Jülich, Jülich, Germany
| | - Bernd Neumaier
- Institut für Neurowissenschaften und Medizin (INM-5), Forschungszentrum Jülich, Jülich, Germany
| | - Andreas Bauer
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany.,Neurological Department, Medical Faculty, Heinrich Heine University Düsseldorf, Düsseldorf, Germany
| | - David Elmenhorst
- Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany.,Division of Medical Psychology, University of Bonn, Bonn, Germany
| |
Collapse
|
16
|
Kuttner S, Wickstrøm KK, Kalda G, Dorraji SE, Martin-Armas M, Oteiza A, Jenssen R, Fenton K, Sundset R, Axelsson J. Machine learning derived input-function in a dynamic 18F-FDG PET study of mice. Biomed Phys Eng Express 2020; 6:015020. [DOI: 10.1088/2057-1976/ab6496] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
17
|
Huang Q, Massey JC, Mińczuk K, Li J, Kundu BK. Non-invasive determination of blood input function to compute rate of myocardial glucose uptake from dynamic FDG PET images of rat heart in vivo: comparative study between the inferior vena cava and the left ventricular blood pool with spill over and partial volume corrections. Phys Med Biol 2019; 64:165010. [PMID: 31307015 DOI: 10.1088/1361-6560/ab3238] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this work was to compute blood input function from the inferior vena cava (IVC) with partial volume (PV) corrections and compare to that obtained from the left ventricular blood pool (LVBP) with spill-over (SP) and PV corrections. These were then used to compute and validate rates of myocardial 2-deoxy-2-[18F]fluoro-D-glucose (FDG) uptake (Ki) from dynamic positron emission tomography (PET) images of rat hearts in vivo in comparison to that obtained from invasive arterial blood sampling. Whole body 60 min dynamic FDG PET/CT imaging of n = 8 control Wistar Kyoto (WKY) rats were performed using Albira trimodal PET/CT/SPECT scanner. Image derived blood input function (IDIF) obtained from IVC corrected for PV averaging (IVC-PV) and IDIF from the left ventricular blood pool (LVBP) with SP and PV corrections (LVBP-SP-PV) were computed. Next, computed Ki (indirect comparison) in a 5-parameter (using IVC-PV) and a 15-parameter (using LVBP-SP-PV) 3-compartment models in WKY rat hearts in vivo were compared to that obtained using arterial blood sampling reported in literature in control Spraque Dawley (SD) rats. Using IVC-PV in a three-compartment five-parameter model resulted in a ~46% deviation in the mean computed Ki compared to that obtained with LVBP-SP-PV in a three-compartment 15-parameter model with a ~57% deviation in the mean computed Ki. The mean computed Ki in WKY rat hearts using the above methods, however, did not differ significantly to that obtained from invasive arterial blood sampling in SD rat hearts (p = 0.91 for IVC-PV and p = 0.58 for LVBP-SP-PV). Hence, Ki obtained in WKY rat hearts with input curve from IVC (IVC-PV) in a dynamic FDG PET scan is comparatively more repetitive to that obtained from the LVBP (LVBP-SP-PV). Ki computed using both the methods, however, agree well with each other and that obtained using arterial blood sampling.
Collapse
Affiliation(s)
- Qiao Huang
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States of America. Equal contribution
| | | | | | | | | |
Collapse
|
18
|
Kinetic modelling and quantification bias in small animal PET studies with [18F]AB5186, a novel 18 kDa translocator protein radiotracer. PLoS One 2019; 14:e0217515. [PMID: 31150436 PMCID: PMC6544349 DOI: 10.1371/journal.pone.0217515] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2019] [Accepted: 05/13/2019] [Indexed: 11/19/2022] Open
Abstract
Introduction Positron Emission Tomography (PET) imaging with selective 18 kDa translocator protein (TSPO) radiotracers has contributed to our understanding on the role of inflammation in disease development and progression. With an increasing number of rodent models of human disease and expansion of the preclinical PET imaging base worldwide, accurate quantification of longitudinal rodent TSPO PET datasets is necessary. This is particularly relevant as TSPO PET quantification relies on invasive blood sampling due to lack of a suitable tissue reference region. Here we investigate the kinetics and quantification bias of a novel TSPO radiotracer [18F]AB5186 in rats using automatic, manual and image derived input functions. Methods [18F]AB5186 was administered intravenously and dynamic PET imaging was acquired over 2 hours. Arterial blood was collected manually to derive a population based input function or using an automatic blood sampler to derive a plasma input function. Manually sampled blood was also used to analyze the [18F]AB5186 radiometabolite profile in plasma and applied to all groups as a population based dataset. Kinetic models were used to estimate distribution volumes (VT) and [18F]AB5186 outcome measure bias was determined. Results [18F]AB5186 distribution in rats was consistent with TSPO expression and at 2 h post-injection 50% of parent compound was still present in plasma. Population based manual sampling methods and image derived input function (IDIF) underestimated VT by ~50% and 88% compared with automatic blood sampling, respectively. The VT variability was lower when using IDIF versus arterial blood sampling methods and analysis of the Bland-Altman plots showed a good agreement between methods of analysis. Conclusion Quantification of TSPO PET rodent data using image-derived methods, which are more amenable for longitudinal scanning of small animals, yields outcome measures with reduced variability and good agreement, albeit biased, compared with invasive blood sampling methods.
Collapse
|
19
|
Suzuki C, Kosugi M, Magata Y. Noninvasive quantitation of rat cerebral blood flow using 99mTc-HMPAO-assessment of input function with dynamic chest planar imaging. EJNMMI Res 2018. [PMID: 29523980 PMCID: PMC5845090 DOI: 10.1186/s13550-018-0375-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cerebral blood flow (CBF) quantitation using technetium-99m hexamethylpropyleneamine oxime (99mTc-HMPAO) generally requires assessment of input function by arterial blood sampling, which would be invasive for small animals. We therefore performed chest dynamic planar imaging, instead of arterial blood sampling, to estimate the input function and establish noninvasive quantitation method of rat CBF using the image-derived input function. RESULTS Integrated radioactivity concentration in the heart-blood pool on planar images (AUCBlood-planar) was identical to that in arterial blood samples (AUCBlood-sampling). Radioactivity concentration in the brain determined by SPECT imaging (CBrain-SPECT) was identical to that using brain sampling (CBrain-sampling). Noninvasively calculated CBF obtained by dividing CBrain-SPECT by AUCBlood-planar was well correlated with conventionally estimated CBF obtained by dividing CBrain-sampling by AUCBlood-sampling. CONCLUSION Rat CBF could be noninvasively quantitated using 99mTc-HMPAO chest dynamic planar imaging and head SPECT imaging without arterial blood sampling.
Collapse
Affiliation(s)
- Chie Suzuki
- Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Mutsumi Kosugi
- Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Yasuhiro Magata
- Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku, Hamamatsu, Shizuoka, 431-3192, Japan.
| |
Collapse
|
20
|
Li Y, Kundu BK. An improved optimization algorithm of the three-compartment model with spillover and partial volume corrections for dynamic FDG PET images of small animal hearts in vivo. Phys Med Biol 2018; 63:055003. [PMID: 29480159 DOI: 10.1088/1361-6560/aaac02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
The three-compartment model with spillover (SP) and partial volume (PV) corrections has been widely used for noninvasive kinetic parameter studies of dynamic 2-[18F] fluoro-2deoxy-D-glucose (FDG) positron emission tomography images of small animal hearts in vivo. However, the approach still suffers from estimation uncertainty or slow convergence caused by the commonly used optimization algorithms. The aim of this study was to develop an improved optimization algorithm with better estimation performance. Femoral artery blood samples, image-derived input functions from heart ventricles and myocardial time-activity curves (TACs) were derived from data on 16 C57BL/6 mice obtained from the UCLA Mouse Quantitation Program. Parametric equations of the average myocardium and the blood pool TACs with SP and PV corrections in a three-compartment tracer kinetic model were formulated. A hybrid method integrating artificial immune-system and interior-reflective Newton methods were developed to solve the equations. Two penalty functions and one late time-point tail vein blood sample were used to constrain the objective function. The estimation accuracy of the method was validated by comparing results with experimental values using the errors in the areas under curves (AUCs) of the model corrected input function (MCIF) and the 18F-FDG influx constant K i . Moreover, the elapsed time was used to measure the convergence speed. The overall AUC error of MCIF for the 16 mice averaged -1.4 ± 8.2%, with correlation coefficients of 0.9706. Similar results can be seen in the overall K i error percentage, which was 0.4 ± 5.8% with a correlation coefficient of 0.9912. The t-test P value for both showed no significant difference. The mean and standard deviation of the MCIF AUC and K i percentage errors have lower values compared to the previously published methods. The computation time of the hybrid method is also several times lower than using just a stochastic algorithm. The proposed method significantly improved the model estimation performance in terms of the accuracy of the MCIF and K i , as well as the convergence speed.
Collapse
Affiliation(s)
- Yinlin Li
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA 22908, United States of America
| | | |
Collapse
|
21
|
Napieczynska H, Kolb A, Katiyar P, Tonietto M, Ud-Dean M, Stumm R, Herfert K, Calaminus C, Pichler BJ. Impact of the Arterial Input Function Recording Method on Kinetic Parameters in Small-Animal PET. J Nucl Med 2018; 59:1159-1164. [PMID: 29476003 DOI: 10.2967/jnumed.117.204164] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Accepted: 01/25/2018] [Indexed: 11/16/2022] Open
Abstract
The goal of this study was to validate the use of an MR-compatible blood sampler (BS) with a detector system based on a lutetium oxyorthosilicate scintillator and avalanche photodiodes for small-animal PET. Methods: Five rats underwent a 60-min 18F-FDG study. For each animal, the arterial input function (AIF) was derived from the BS recording, from manual sampling (MS), and from the PET image. These AIFs were applied for kinetic modeling of the striatum using the irreversible 2-tissue-compartment model. The MS-based technique with a dispersion correction served as a reference approach, and the kinetic parameters that were estimated with the BS- and the image-derived AIFs were compared with the reference values. Additionally, the effect of applying a population-based activity ratio for plasma to whole blood (p/wb) and the dispersion correction was assessed. Results: The K1, k2, and k3 values estimated with the reference approach were 0.174 ± 0.037 mL/min/cm3, 0.342 ± 0.080 1/min, and 0.048 ± 0.009 1/min, respectively. The corresponding parameters obtained with the BS- and image-derived AIFs deviated from these values by 0.6%-18.8% and 16.7%-47.9%, respectively. To compensate for the error in the BS-based technique, data from one MS collected at the end of the experiment were combined with the data from the first 10 min of the BS recording. This approach reduced the deviation in the kinetic parameters to 1.8%-6.3%. Using p/wb led to a 1.7%-8.3% difference from the reference parameters. The sensitivity of the BS was 23%, the energy resolution for the 511-keV photopeak was 19%, and the timing resolution was 11.2 ns. Conclusion: Online recording of the blood activity level with the BS allows precise measurement of AIF, without loss of blood volume. Combining the BS data with one MS is the most accurate approach for the data analysis. The high sensitivity of the device may allow application of lower radioactivity doses.
Collapse
Affiliation(s)
- Hanna Napieczynska
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany .,International Max Planck Research School for Cognitive and Systems Neuroscience, Tuebingen, Germany; and
| | - Armin Kolb
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Prateek Katiyar
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Matteo Tonietto
- Institute for Brain and Spinal Cord, Sorbonne University, UPMC, INSERM U 1127, CNRS UMR 7225, Paris, France
| | - Minhaz Ud-Dean
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Ramona Stumm
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Kristina Herfert
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Carsten Calaminus
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| | - Bernd J Pichler
- Werner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University of Tuebingen, Tuebingen, Germany
| |
Collapse
|
22
|
Khalighi MM, Deller TW, Fan AP, Gulaka PK, Shen B, Singh P, Park JH, Chin FT, Zaharchuk G. Image-derived input function estimation on a TOF-enabled PET/MR for cerebral blood flow mapping. J Cereb Blood Flow Metab 2018; 38:126-135. [PMID: 28155582 PMCID: PMC5757438 DOI: 10.1177/0271678x17691784] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 01/04/2017] [Accepted: 01/10/2017] [Indexed: 11/15/2022]
Abstract
15O-H2O PET imaging is an accurate method to measure cerebral blood flow (CBF) but it requires an arterial input function (AIF). Historically, image-derived AIF estimation suffers from low temporal resolution, spill-in, and spill-over problems. Here, we optimized tracer dose on a time-of-flight PET/MR according to the acquisition-specific noise-equivalent count rate curve. An optimized dose of 850 MBq of 15O-H2O was determined, which allowed sufficient counts to reconstruct a short time-frame PET angiogram (PETA) during the arterial phase. This PETA enabled the measurement of the extent of spill-over, while an MR angiogram was used to measure the true arterial volume for AIF estimation. A segment of the high cervical arteries outside the brain was chosen, where the measured spill-in effects were minimal. CBF studies were performed twice with separate [15O]-H2O injections in 10 healthy subjects, yielding values of 88 ± 16, 44 ± 9, and 58 ± 11 mL/min/100 g for gray matter, white matter, and whole brain, with intra-subject CBF differences of 5.0 ± 4.0%, 4.1 ± 3.3%, and 4.5 ± 3.7%, respectively. A third CBF measurement after the administration of 1 g of acetazolamide showed 35 ± 23%, 29 ± 20%, and 33 ± 22% increase in gray matter, white matter, and whole brain, respectively. Based on these findings, the proposed noninvasive AIF method provides robust CBF measurement with 15O-H2O PET.
Collapse
Affiliation(s)
| | | | | | | | - Bin Shen
- Radiology Department, Stanford University, Stanford, CA, USA
| | - Prachi Singh
- Radiology Department, Stanford University, Stanford, CA, USA
| | - Jun-Hyung Park
- Molecular Imaging Program, Stanford University, Stanford, CA, USA
| | - Frederick T Chin
- Radiology Department, Stanford University, Stanford, CA, USA
- Molecular Imaging Program, Stanford University, Stanford, CA, USA
| | - Greg Zaharchuk
- Radiology Department, Stanford University, Stanford, CA, USA
- Molecular Imaging Program, Stanford University, Stanford, CA, USA
| |
Collapse
|
23
|
Fang YHD, Liu YC, Ho KC, Kuo FC, Yang CF, Yen TC, Hsieh IC. Single-scan rest/stress imaging with 99mTc-Sestamibi and cadmium zinc telluride-based SPECT for hyperemic flow quantification: A feasibility study evaluated with cardiac magnetic resonance imaging. PLoS One 2017; 12:e0183402. [PMID: 28817662 PMCID: PMC5560722 DOI: 10.1371/journal.pone.0183402] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Accepted: 07/14/2017] [Indexed: 12/21/2022] Open
Abstract
Introduction We aimed to evaluate whether the hyperemic myocardial blood flow (MBF) can be estimated using cadmium zinc telluride (CZT)-based single-photon emission computed tomography (SPECT) cameras with a single, rapid rest/stress dynamic scan. Dynamic contrast-enhanced (DCE) cardiac magnetic resonance imaging (MRI) was used as a reference modality for flow measurement. Materials and methods The proposed protocol included both the rest and stress acquisitions within a 24-min scan. Patients were first injected with 99mTc-Sestamibi at the resting state. Sixty minutes after the first injection, the subject was positioned via scintigraphy, after which the list-mode data acquisition was initiated and continued for 24 minutes. Five minutes after data acquisition was initiated, a stressed state was induced via dipyridamole infusion, after which a second dose of 99mTc-Sestamibi was injected. Dynamic SPECT images were reconstructed for all subjects, who also underwent T1-weighted cardiac DCE-MRI performed on days other than those of the SPECT studies. MBF values were estimated for the rest and stress MRI studies, and for the stress portion of the SPECT study. The SPECT-measured hyperemic MBF was compared with the MR-measured hyperemic MBF and coronary flow reserve (CFR), based on the regions of interest. Results A total of 30 subjects were included in this study. The hyperemic MBF estimated from SPECT showed a strong correlation with the MR-measured hyperemic MBF (r2 = 0.76) and a modest correlation with the MR-measured CFR (r2 = 0.56). Using MR-measured CFR <1.3 as a cutoff for coronary stenosis, we found that the SPECT-measured hyperemic MBF served as a useful clinical index with 94% sensitivity, 90% specificity, and 93% accuracy. Conclusions Hyperemic MBF can be measured with a rapid, single-scan rest/stress study with CZT-based SPECT cameras.
Collapse
Affiliation(s)
- Yu-Hua Dean Fang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
| | - Yuan-Chang Liu
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Kung-Chu Ho
- Department of Nuclear Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Feng-Cheng Kuo
- Department of Nuclear Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan
| | - Ching-Fang Yang
- Department of Medical Imaging and Radiological Sciences, Chang Gung University, Taoyuan, Taiwan
| | - Tzu-Chen Yen
- Department of Nuclear Medicine, Chang Gung Memorial Hospital, Linkou, Taiwan
- Center for Advanced Molecular Imaging and Translation & Cyclotron Center, Chang Gung Memorial Hospital, Linkou, Taiwan
- * E-mail: (TY); (IH)
| | - I-Chang Hsieh
- Department of Cardiology, Chang Gung Memorial Hospital, Linkou, Taiwan
- * E-mail: (TY); (IH)
| |
Collapse
|
24
|
Pampaloni MH, Shrestha UM, Sciammarella M, Seo Y, Gullberg GT, Botvinick EH. Noninvasive PET quantitative myocardial blood flow with regadenoson for assessing cardiac allograft vasculopathy in orthotopic heart transplantation patients. J Nucl Cardiol 2017; 24:1134-1144. [PMID: 28138813 PMCID: PMC5534390 DOI: 10.1007/s12350-016-0761-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Revised: 08/22/2016] [Indexed: 10/20/2022]
Abstract
BACKGROUND Risk stratification and early detection of cardiac allograft vasculopathy (CAV) is essential in orthotopic heart transplantation (OHT) patients. This study assesses the changes in myocardial blood flow (MBF) noninvasively in OHT patients using quantitative cardiac PET with regadenoson. METHODS Twelve patients (Group 1) (8 males, 4 females, mean age 55 ± 7 years) with no history of post OHT myocardial ischemia were enrolled 5.4 ± 2.0 years after OHT. Fifteen patients (Group 2) (9 males, 6 females, mean age 71 ± 9 years) with intermediate pretest probability but not documented evidence for coronary artery disease (CAD) were also included to serve as control. Global and regional MBFs were assessed using dynamic 13N-NH3 PET at rest and during regadenoson-induced hyperemia. The coronary flow reserve (CFR) was also calculated as the ratio of hyperemic to resting MBF. RESULTS Mean regadenoson-induced rate-pressure products were similar in both groups, while there was an increase in resting rate-pressure product in Group 1 patients. Both mean and median values of resting MBF were higher in Group 1 than Group 2 patients (1.33 ± 0.31 and 1.01 ± 0.21 mL/min/g for Groups 1 and 2, respectively, P < .001), while mean hyperemic MBF values were similar in both Groups (2.68 ± 0.84 and 2.64 ± 0.94 mL/min/g, P = NS) but median hyperemic MBF values were lower in Group 1 than Group 2 patients (2.0 vs. 2.60 mL/min/g, P = .018). Both mean and median CFR values demonstrated a significant reduction for Group 1 compared to Group 2 patients (2.07 ± 0.74 vs 2.63 ± 0.48, P = .025). CONCLUSIONS This study suggests that the MBF in OHT patients may be abnormal at resting state with diminished CFR. This hints that the epicardial and microvascular coronary subsystem may be exacerbated after OHT leading to the gradual progression of CAV.
Collapse
Affiliation(s)
- Miguel Hernandez Pampaloni
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Uttam M Shrestha
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA.
| | - Maria Sciammarella
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
| | - Youngho Seo
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Grant T Gullberg
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Elias H Botvinick
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
| |
Collapse
|
25
|
Huang SC, Wu LC, Lin WC, Lin KP, Liu RS. Adaptive Weighted Nonlinear Least Squares Method for Fluorodeoxyglucose Positron Emission Tomography Quantification. J Med Biol Eng 2017. [DOI: 10.1007/s40846-017-0313-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
26
|
Cicone F, Viertl D, Quintela Pousa AM, Denoël T, Gnesin S, Scopinaro F, Vozenin MC, Prior JO. Cardiac Radionuclide Imaging in Rodents: A Review of Methods, Results, and Factors at Play. Front Med (Lausanne) 2017; 4:35. [PMID: 28424774 PMCID: PMC5372793 DOI: 10.3389/fmed.2017.00035] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Accepted: 03/15/2017] [Indexed: 12/19/2022] Open
Abstract
The interest around small-animal cardiac radionuclide imaging is growing as rodent models can be manipulated to allow the simulation of human diseases. In addition to new radiopharmaceuticals testing, often researchers apply well-established probes to animal models, to follow the evolution of the target disease. This reverse translation of standard radiopharmaceuticals to rodent models is complicated by technical shortcomings and by obvious differences between human and rodent cardiac physiology. In addition, radionuclide studies involving small animals are affected by several extrinsic variables, such as the choice of anesthetic. In this paper, we review the major cardiac features that can be studied with classical single-photon and positron-emitting radiopharmaceuticals, namely, cardiac function, perfusion and metabolism, as well as the results and pitfalls of small-animal radionuclide imaging techniques. In addition, we provide a concise guide to the understanding of the most frequently used anesthetics such as ketamine/xylazine, isoflurane, and pentobarbital. We address in particular their mechanisms of action and the potential effects on radionuclide imaging. Indeed, cardiac function, perfusion, and metabolism can all be significantly affected by varying anesthetics and animal handling conditions.
Collapse
Affiliation(s)
- Francesco Cicone
- Department of Nuclear Medicine and Molecular Imaging, University Hospital of Lausanne, Lausanne, Switzerland.,Nuclear Medicine, Department of Surgical and Medical Sciences and Translational Medicine, "Sapienza" University of Rome, Rome, Italy
| | - David Viertl
- Department of Nuclear Medicine and Molecular Imaging, University Hospital of Lausanne, Lausanne, Switzerland
| | - Ana Maria Quintela Pousa
- Laboratory of Radiation Oncology, Service of Radiation-Oncology, Department of Oncology, University Hospital of Lausanne, Lausanne, Switzerland
| | - Thibaut Denoël
- Department of Nuclear Medicine and Molecular Imaging, University Hospital of Lausanne, Lausanne, Switzerland
| | - Silvano Gnesin
- Institute of Radiation Physics, University Hospital of Lausanne, Lausanne, Switzerland
| | - Francesco Scopinaro
- Nuclear Medicine, Department of Surgical and Medical Sciences and Translational Medicine, "Sapienza" University of Rome, Rome, Italy
| | - Marie-Catherine Vozenin
- Laboratory of Radiation Oncology, Service of Radiation-Oncology, Department of Oncology, University Hospital of Lausanne, Lausanne, Switzerland
| | - John O Prior
- Department of Nuclear Medicine and Molecular Imaging, University Hospital of Lausanne, Lausanne, Switzerland
| |
Collapse
|
27
|
Shrestha U, Sciammarella M, Alhassen F, Yeghiazarians Y, Ellin J, Verdin E, Boyle A, Seo Y, Botvinick EH, Gullberg GT. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation. J Nucl Cardiol 2017; 24:268-277. [PMID: 26715603 PMCID: PMC4927413 DOI: 10.1007/s12350-015-0320-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Accepted: 10/21/2015] [Indexed: 01/09/2023]
Abstract
BACKGROUND The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). METHODS Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. RESULTS The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). CONCLUSIONS Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.
Collapse
Affiliation(s)
- Uttam Shrestha
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA.
- Division of Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA, USA.
| | - Maria Sciammarella
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
| | - Fares Alhassen
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Yerem Yeghiazarians
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
| | - Justin Ellin
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Emily Verdin
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
| | - Andrew Boyle
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
- School of Medicine and Public Health, University of Newcastle, Newcastle, Australia
| | - Youngho Seo
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
- Division of Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| | - Elias H Botvinick
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
- Division of Cardiology, Department of Medicine, University of California, San Francisco, CA, USA
| | - Grant T Gullberg
- Department of Radiology and Biomedical Imaging, University of California, 185 Berry St., Suite 350, San Francisco, CA, 94143-0946, USA
- Division of Molecular Biophysics and Integrated Bioimaging, Lawrence Berkeley National Laboratory, Berkeley, CA, USA
| |
Collapse
|
28
|
Feng T, Tsui BMW, Li X, Vranesic M, Lodge MA, Gulaldi NCM, Szabo Z. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney. Med Phys 2016; 42:6736-44. [PMID: 26520763 DOI: 10.1118/1.4934375] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The radioligand 11C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of 11C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. METHODS The experimental animals were injected with [11C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. RESULTS In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio=1±0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. CONCLUSIONS The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of 11C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.
Collapse
Affiliation(s)
- Tao Feng
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Benjamin M W Tsui
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Xin Li
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Melin Vranesic
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Martin A Lodge
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Nedim C M Gulaldi
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| | - Zsolt Szabo
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287
| |
Collapse
|
29
|
Jochimsen TH, Zeisig V, Schulz J, Werner P, Patt M, Patt J, Dreyer AY, Boltze J, Barthel H, Sabri O, Sattler B. Fully automated calculation of image-derived input function in simultaneous PET/MRI in a sheep model. EJNMMI Phys 2016; 3:2. [PMID: 26872658 PMCID: PMC4752572 DOI: 10.1186/s40658-016-0139-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 01/29/2016] [Indexed: 12/04/2022] Open
Abstract
Background Obtaining the arterial input function (AIF) from image data in dynamic positron emission tomography (PET) examinations is a non-invasive alternative to arterial blood sampling. In simultaneous PET/magnetic resonance imaging (PET/MRI), high-resolution MRI angiographies can be used to define major arteries for correction of partial-volume effects (PVE) and point spread function (PSF) response in the PET data. The present study describes a fully automated method to obtain the image-derived input function (IDIF) in PET/MRI. Results are compared to those obtained by arterial blood sampling. Methods To segment the trunk of the major arteries in the neck, a high-resolution time-of-flight MRI angiography was postprocessed by a vessel-enhancement filter based on the inertia tensor. Together with the measured PSF of the PET subsystem, the arterial mask was used for geometrical deconvolution, yielding the time-resolved activity concentration averaged over a major artery. The method was compared to manual arterial blood sampling at the hind leg of 21 sheep (animal stroke model) during measurement of blood flow with O15-water. Absolute quantification of activity concentration was compared after bolus passage during steady state, i.e., between 2.5- and 5-min post injection. Cerebral blood flow (CBF) values from blood sampling and IDIF were also compared. Results The cross-calibration factor obtained by comparing activity concentrations in blood samples and IDIF during steady state is 0.98 ± 0.10. In all examinations, the IDIF provided a much earlier and sharper bolus peak than in the time course of activity concentration obtained by arterial blood sampling. CBF using the IDIF was 22 % higher than CBF obtained by using the AIF yielded by blood sampling. Conclusions The small deviation between arterial blood sampling and IDIF during steady state indicates that correction of PVE and PSF is possible with the method presented. The differences in bolus dynamics and, hence, CBF values can be explained by the different sampling locations (hind leg vs. major neck arteries) with differences in delay/dispersion. It will be the topic of further work to test the method on humans with the perspective of replacing invasive blood sampling by an IDIF using simultaneous PET/MRI.
Collapse
Affiliation(s)
- Thies H Jochimsen
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany.
| | - Vilia Zeisig
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Jessica Schulz
- Max Planck Institute for Human Cognitive and Brain Sciences, Stephanstr. 1a, Leipzig, D-04103, Germany
| | - Peter Werner
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Marianne Patt
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Jörg Patt
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Antje Y Dreyer
- Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103, Germany.,Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103, Germany
| | - Johannes Boltze
- Fraunhofer Institute of Cell Therapy and Immunology, Perlickstr. 1, Leipzig, D-04103, Germany.,Translational Centre for Regenerative Medicine, University Leipzig, Philipp-Rosenthal-Str. 55, Leipzig, D-04103, Germany.,Fraunhofer Research Institution of Marine Biotechnology and Institute for Medical and Marine Biotechnology, University of Lübeck, Lübeck, Germany
| | - Henryk Barthel
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Osama Sabri
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| | - Bernhard Sattler
- Department of Nuclear Medicine, Leipzig University Hospital, Liebigstr. 18, Leipzig, Germany
| |
Collapse
|
30
|
Kastis GA, Gaitanis A, Samartzis AP, Fokas AS. The SRT reconstruction algorithm for semiquantification in PET imaging. Med Phys 2015; 42:5970-82. [DOI: 10.1118/1.4931409] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
31
|
Dexamethasone-induced insulin resistance: kinetic modeling using novel PET radiopharmaceutical 6-deoxy-6-[(18)F]fluoro-D-glucose. Mol Imaging Biol 2015; 16:710-20. [PMID: 24819311 DOI: 10.1007/s11307-014-0737-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE An insulin-resistant rat model, induced by dexamethasone, was used to evaluate a Michaelis-Menten-based kinetic model using 6-deoxy-6-[(18)F]fluoro-D-glucose (6-[(18)F]FDG) to quantify glucose transport with PET. PROCEDURES Seventeen, male, Sprague-Dawley rats were studied in three groups: control (Ctrl), control + insulin (Ctrl + I), and dexamethasone + insulin (Dex + I). PET scans were acquired for 2 h under euglycemic conditions in the Ctrl group and under hyperinsulinemic-euglycemic conditions in the Ctrl + I and Dex + I groups. RESULTS Glucose transport, assessed according to the 6-[(18)F]FDG concentration, was highest in skeletal muscle in the Ctrl + I, intermediate in the Dex + I, and lowest in the Ctrl group, while that in the brain was similar among the groups. Modeling analysis applied to the skeletal muscle uptake curves yielded values of parameters related to glucose transport that were greatest in the Ctrl + I group and increased to a lesser degree in the Dex + I group, compared to the Ctrl group. CONCLUSION 6-[(18)F]FDG and the Michaelis-Menten-based model can be used to measure insulin-stimulated glucose transport under basal and an insulin resistant state in vivo.
Collapse
|
32
|
Evans E, Buonincontri G, Izquierdo D, Methner C, Hawkes RC, Ansorge RE, Krieg T, Carpenter TA, Sawiak SJ. Combining MRI with PET for partial volume correction improves image-derived input functions in mice. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 2015; 62:628-633. [PMID: 26213413 PMCID: PMC4510926 DOI: 10.1109/tns.2015.2433897] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Accurate kinetic modelling using dynamic PET requires knowledge of the tracer concentration in plasma, known as the arterial input function (AIF). AIFs are usually determined by invasive blood sampling, but this is prohibitive in murine studies due to low total blood volumes. As a result of the low spatial resolution of PET, image-derived input functions (IDIFs) must be extracted from left ventricular blood pool (LVBP) ROIs of the mouse heart. This is challenging because of partial volume and spillover effects between the LVBP and myocardium, contaminating IDIFs with tissue signal. We have applied the geometric transfer matrix (GTM) method of partial volume correction (PVC) to 12 mice injected with 18F-FDG affected by a Myocardial Infarction (MI), of which 6 were treated with a drug which reduced infarction size [1]. We utilised high resolution MRI to assist in segmenting mouse hearts into 5 classes: LVBP, infarcted myocardium, healthy myocardium, lungs/body and background. The signal contribution from these 5 classes was convolved with the point spread function (PSF) of the Cambridge split magnet PET scanner and a non-linear fit was performed on the 5 measured signal components. The corrected IDIF was taken as the fitted LVBP component. It was found that the GTM PVC method could recover an IDIF with less contamination from spillover than an IDIF extracted from PET data alone. More realistic values of Ki were achieved using GTM IDIFs, which were shown to be significantly different (p<0.05) between the treated and untreated groups.
Collapse
Affiliation(s)
- Eleanor Evans
- Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, UK, CB2 0QQ ( )
| | - Guido Buonincontri
- Wolfson Brain Imaging Centre and the Department of Medicine, University of Cambridge, Cambridge, UK, CB2 0QQ ( )
| | - David Izquierdo
- Athinoula A. Martinos Center for Biomedical Imaging, 149 Thirteenth Street, Suite 2301, Charlestown, MA, 02129 ( )
| | - Carmen Methner
- Department of Medicine, University of Cambridge and is now at Oregon Health and Science University, Portland, OR, 97239 ( )
| | - Rob C Hawkes
- Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, UK, CB2 0QQ ( )
| | - Richard E Ansorge
- Department of Physics, University of Cambridge, Cambridge, UK, CB3 0HE ( )
| | - Thomas Krieg
- Member of the Department of Medicine, University of Cambridge, Cambridge, UK, CB2 0QQ ( )
| | - T Adrian Carpenter
- Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, UK, CB2 0QQ ( )
| | - Stephen J Sawiak
- Member of both the Wolfson Brain Imaging Centre, and the Behavioural and Clinical Neurosciences Institute, University of Cambridge, Cambridge, UK, CB2 3EB ( )
| |
Collapse
|
33
|
Su Y, Blazey TM, Snyder AZ, Raichle ME, Hornbeck RC, Aldea P, Morris JC, Benzinger TLS. Quantitative amyloid imaging using image-derived arterial input function. PLoS One 2015; 10:e0122920. [PMID: 25849581 PMCID: PMC4388540 DOI: 10.1371/journal.pone.0122920] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2014] [Accepted: 02/24/2015] [Indexed: 11/19/2022] Open
Abstract
Amyloid PET imaging is an indispensable tool widely used in the investigation, diagnosis and monitoring of Alzheimer’s disease (AD). Currently, a reference region based approach is used as the mainstream quantification technique for amyloid imaging. This approach assumes the reference region is amyloid free and has the same tracer influx and washout kinetics as the regions of interest. However, this assumption may not always be valid. The goal of this work is to evaluate an amyloid imaging quantification technique that uses arterial region of interest as the reference to avoid potential bias caused by specific binding in the reference region. 21 participants, age 58 and up, underwent Pittsburgh compound B (PiB) PET imaging and MR imaging including a time-of-flight (TOF) MR angiography (MRA) scan and a structural scan. FreeSurfer based regional analysis was performed to quantify PiB PET data. Arterial input function was estimated based on coregistered TOF MRA using a modeling based technique. Regional distribution volume (VT) was calculated using Logan graphical analysis with estimated arterial input function. Kinetic modeling was also performed using the estimated arterial input function as a way to evaluate PiB binding (DVRkinetic) without a reference region. As a comparison, Logan graphical analysis was also performed with cerebellar cortex as reference to obtain DVRREF. Excellent agreement was observed between the two distribution volume ratio measurements (r>0.89, ICC>0.80). The estimated cerebellum VT was in line with literature reported values and the variability of cerebellum VT in the control group was comparable to reported variability using arterial sampling data. This study suggests that image-based arterial input function is a viable approach to quantify amyloid imaging data, without the need of arterial sampling or a reference region. This technique can be a valuable tool for amyloid imaging, particularly in population where reference normalization may not be accurate.
Collapse
Affiliation(s)
- Yi Su
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
- Knight Alzheimer’s Disease Research Center (ADRC), Washington University School of Medicine, Saint Louis, Missouri, United States of America
- * E-mail:
| | - Tyler M. Blazey
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - Abraham Z. Snyder
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - Marcus E. Raichle
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - Russ C. Hornbeck
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
- Knight Alzheimer’s Disease Research Center (ADRC), Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - Patricia Aldea
- Knight Alzheimer’s Disease Research Center (ADRC), Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - John C. Morris
- Department of Neurology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
- Knight Alzheimer’s Disease Research Center (ADRC), Washington University School of Medicine, Saint Louis, Missouri, United States of America
| | - Tammie L. S. Benzinger
- Department of Radiology, Washington University School of Medicine, Saint Louis, Missouri, United States of America
- Knight Alzheimer’s Disease Research Center (ADRC), Washington University School of Medicine, Saint Louis, Missouri, United States of America
- Department of Neurosurgery, Washington University School of Medicine, Saint Louis, Missouri, United States of America
| |
Collapse
|
34
|
Kundu BK, Zhong M, Sen S, Davogustto G, Keller SR, Taegtmeyer H. Remodeling of glucose metabolism precedes pressure overload-induced left ventricular hypertrophy: review of a hypothesis. Cardiology 2015; 130:211-20. [PMID: 25791172 DOI: 10.1159/000369782] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Accepted: 11/10/2014] [Indexed: 12/14/2022]
Abstract
When subjected to pressure overload, the ventricular myocardium shifts from fatty acids to glucose as its main source for energy provision and frequently increases its mass. Here, we review the evidence in support of the concept that metabolic remodeling, measured as an increased myocardial glucose uptake using dynamic positron emission tomography (PET) with the glucose analogue 2-deoxy-2-[(18)F]fluoro-D-glucose (FDG), precedes the onset of left ventricular hypertrophy (LVH) and heart failure. Consistent with this, early intervention with propranolol, which attenuates glucose uptake, prevents the maladaptive metabolic response and preserves cardiac function in vivo. We also review ex vivo studies suggesting a link between dysregulated myocardial glucose metabolism, intracellular accumulation of glucose 6-phosphate (G6P) and contractile dysfunction of the heart. G6P levels correlate with activation of mTOR (mechanistic target of rapamycin) and endoplasmic reticulum stress. This sequence of events could be prevented by pretreatment with rapamycin (mTOR inhibition) or metformin (enzyme 5'-AMP-activated protein kinase activation). In conclusion, we propose that metabolic imaging with FDG PET may provide a novel approach to guide the treatment of patients with hypertension-induced LVH.
Collapse
Affiliation(s)
- Bijoy K Kundu
- Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Va., USA
| | | | | | | | | | | |
Collapse
|
35
|
Waller AP, Kalyanasundaram A, Hayes S, Periasamy M, Lacombe VA. Sarcoplasmic reticulum Ca2+ ATPase pump is a major regulator of glucose transport in the healthy and diabetic heart. Biochim Biophys Acta Mol Basis Dis 2015; 1852:873-81. [PMID: 25615793 DOI: 10.1016/j.bbadis.2015.01.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 12/18/2014] [Accepted: 01/14/2015] [Indexed: 01/12/2023]
Abstract
Despite intensive research, the pathways that mediate calcium (Ca(2+))-stimulated glucose transport in striated muscle remain elusive. Since the sarcoplasmic reticulum calcium ATPase (SERCA) pump tightly regulates cytosolic [Ca(2+)], we investigated whether the SERCA pump is a major regulator of cardiac glucose transport. We used healthy and insulin-deficient diabetic transgenic (TG) mice expressing SERCA1a in the heart. Active cell surface glucose transporter (GLUT)-4 was measured by a biotinylated photolabeled assay in the intact perfused myocardium and isolated myocytes. In healthy TG mice, cardiac-specific SERCA1a expression increased active cell-surface GLUT4 and glucose uptake in the myocardium, as well as whole body glucose tolerance. Diabetes reduced active cell-surface GLUT4 content and glucose uptake in the heart of wild type mice, all of which were preserved in diabetic TG mice. Decreased basal AS160 and increased proportion of calmodulin-bound AS160 paralleled the increase in cell surface GLUT4 content in the heart of TG mice, suggesting that AS160 regulates GLUT trafficking by a Ca(2+)/calmodulin dependent pathway. In addition, cardiac-specific SERCA1a expression partially rescues hyperglycemia during diabetes. Collectively, these data suggested that the SERCA pump is a major regulator of cardiac glucose transport by an AS160 dependent mechanism during healthy and insulin-deficient state. Our data further indicated that cardiac-specific SERCA overexpression rescues diabetes induced-alterations in cardiac glucose transport and improves whole body glucose homeostasis. Therefore, findings from this study provide novel mechanistic insights linking upregulation of the SERCA pump in the heart as a potential therapeutic target to improve glucose metabolism during diabetes.
Collapse
Affiliation(s)
| | - Anuradha Kalyanasundaram
- Department of Physiology and Cell Biology, College of Medicine and Public Health, The Ohio State University, USA
| | - Summer Hayes
- College of Pharmacy, The Ohio State University, USA
| | - Muthu Periasamy
- Department of Physiology and Cell Biology, College of Medicine and Public Health, The Ohio State University, USA; Davis Heart and Lung Research Institute, Columbus, OH 43210, USA
| | - Véronique A Lacombe
- Department of Physiological Sciences, Oklahoma State University, Stillwater, OK, USA.
| |
Collapse
|
36
|
Pérez-Campaña C, Gómez-Vallejo V, Puigivila M, Martin A, Calvo-Fernández T, Moya SE, Larsen ST, Gispert JD, Llop J. Assessing lung inflammation after nanoparticle inhalation using 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography imaging. Mol Imaging Biol 2014; 16:264-73. [PMID: 24002615 DOI: 10.1007/s11307-013-0682-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE The aim of the present study was to evaluate the use of 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) as a noninvasive strategy to assess the time course of inflammatory processes after inhalation of ZnO nanoparticles (NPs) in rats. PROCEDURES Healthy, male Sprague-Dawley rats (n = 30) were divided in two groups of 15 animals each. Animals from one group (n = 15) were submitted to ZnO NPs inhalation in a chamber (10 nm to 4 μm particle size; maximum in number concentration, ∼ 200 nm; concentration = 245 mg/m(3)). Animals from the other group (n = 15, sham group) were also exposed following the same procedure, but no NPs were introduced into the chamber. Six animals per group were submitted to [(18)F]FDG-positron emission tomography (PET) studies at days 1, 7, and 28 after exposition, and the [(18)F]FDG influx constant (K i ) for the lungs was calculated using Patlak graphical analysis and an image derived blood input function. Nine animals per group were killed at 1, 7 and 28 days after exposure (n = 3 per group and time point), and the lungs were harvested and submitted to immunohistochemical and histological analysis. RESULTS Significantly higher mean whole-lung K i values were obtained for animals exposed to NPs at days 1 and 7 after exposure (0.0045 ± 0.0016 min(-1) and 0.0047 ± 0.0015 min(-1), respectively) compared to controls (0.0024 ± 0.0010 min(-1) and 0.0019 ± 0.0011 min(-1) at 1 and 7 days, respectively). The K i value for exposed animals dropped to 0.0023 ± 0.0010 min(-1) at day 28. This value was not significantly different from the values obtained at 1, 7, and 28 days for the control group. Immunofluorescence staining on lung tissue slices from animals exposed to ZnO NPs showed an increase in CD11b reactivity at days 1 and 7, followed by a decrease in CD11b positive cells at 28 days. Hematoxylin-eosin staining showed histological alterations in the exposed lungs to ZnO NPs at days 1 and 7 that recovered at 28 days postexposure. CONCLUSIONS The [(18)F]FDG influx rate constant (K i ) could be determined by PET using Patlak analysis and a corrected image derived input function. Higher K i values were obtained for animals exposed to ZnO NPs at days 1 and 7 after exposition. These results were in good concordance with immunohistochemical assays performed on harvested tissue samples.
Collapse
Affiliation(s)
- Carlos Pérez-Campaña
- Radiochemistry Department, Molecular Imaging Unit, CIC biomaGUNE, San Sebastian, Spain
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Lanz B, Poitry-Yamate C, Gruetter R. Image-derived input function from the vena cava for 18F-FDG PET studies in rats and mice. J Nucl Med 2014; 55:1380-8. [PMID: 24914058 DOI: 10.2967/jnumed.113.127381] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2013] [Accepted: 04/02/2014] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED Measurement of arterial input function is a restrictive aspect for quantitative (18)F-FDG PET studies in rodents because of their small total blood volume and the related difficulties in withdrawing blood. METHODS In the present study, we took advantage of the high spatial resolution of a recent dedicated small-animal scanner to extract the input function from the (18)F-FDG PET images in Sprague-Dawley rats (n = 4) and C57BL/6 mice (n = 5), using the vena cava. In the rat experiments, the validation of the image-derived input function (IDIF) method was made using an external microvolumetric blood counter as reference for the determination of the arterial input function, the measurement of which was confirmed by additional manually obtained blood samples. Correction for tracer bolus dispersion in blood between the vena cava and the arterial tree was applied. In addition, simulation studies were undertaken to probe the impact of the different IDIF extraction approaches on the determined cerebral metabolic rate of glucose (CMRGlc). In the mice measurements, the IDIF was used to compute the CMRGlc, which was compared with previously reported values, using the Patlak approach. RESULTS The presented IDIF from the vena cava showed a robust determination of CMRGlc using either the compartmental modeling or the Patlak approach, even without bolus dispersion correction or blood sampling, with an underestimation of CMRGlc of 7% ± 16% as compared with the reference data. Using this approach in the mice experiments, we measured a cerebral metabolic rate in the cortex of 0.22 ± 0.10 μmol/g/min (mean ± SD), in good agreement with previous (18)F-FDG studies in the mouse brain. In the rat experiments, dispersion correction of the IDIF and additional scaling of the IDIF using a single manual blood sample enabled an optimized determination of CMRGlc, with an underestimation of 6% ± 7%. CONCLUSION The vena cava time-activity curve is therefore a minimally invasive alternative for the measurement of the (18)F-FDG input function in rats and mice, without the complications associated with repetitive blood sampling.
Collapse
Affiliation(s)
- Bernard Lanz
- Laboratory for Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Carole Poitry-Yamate
- Center for Biomedical Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Rolf Gruetter
- Laboratory for Functional and Metabolic Imaging (LIFMET), Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland Center for Biomedical Imaging, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland Department of Radiology, University of Lausanne, Lausanne, Switzerland; and Department of Radiology, University of Geneva, Geneva, Switzerland
| |
Collapse
|
38
|
Pahk K, Oh SY, Jeong E, Lee SH, Woo SK, Yu JW, Choe JG, Cheon GJ. Is it Feasible to Use the Commercially Available Autoquantitation Software for the Evaluation of Myocardial Viability on Small-Animal Cardiac F-18 FDG PET Scan? Nucl Med Mol Imaging 2014; 47:104-14. [PMID: 24900090 DOI: 10.1007/s13139-013-0206-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2013] [Revised: 04/23/2013] [Accepted: 04/24/2013] [Indexed: 11/28/2022] Open
Abstract
PURPOSE To evaluate the reliability of quantitation of myocardial viability on cardiac F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) scans with three different methods of visual scoring system, autoquantitation using commercially available autoquantitation software, and infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map in rat hearts. METHODS A myocardial infarct (MI) model was made by left anterior descending artery (LAD) ligation in rat hearts. Eighteen MI rats underwent cardiac FDG-PET-computed tomography (CT) twice within a 4-week interval. Myocardium was partitioned into 20 segments for the comparison, and then we quantitated non-viable myocardium on cardiac FDG PET-CT with three different methods: method A-infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map; method B-summed MI score (SMS) by a four-point visual scoring system; method C-metabolic non-viable values by commercially available autoquantitation software. Changes of non-viable myocardium on serial PET-CT scans with three different methods were calculated by the change of each parameter. Correlation and reproducibility were evaluated between the different methods. RESULTS Infarct-size measurement, visual SMS, and non-viable values by autoquantitation software presented proportional relationship to each other. All the parameters of methods A, B, and C showed relatively good correlation between each other. Among them, infarct-size measurement (method A) and autoquantitation software (method C) showed the best correlation (r = 0.87, p < 0.001). When we evaluated the changes of non-viable myocardium on the serial FDG-PET-CT- however, autoquantitation program showed less correlation with the other methods. Visual assessment (method B) and those of infarct size (method A) showed the best correlation (r = 0.54, p = 0.02) for the assessment of interval changes. CONCLUSIONS Commercially available quantitation software could be applied to measure the myocardial viability on small animal cardiac FDG-PET-CT scan. This kind of quantitation showed good correlation with infarct size measurement by histogram-based maximum pixel threshold identification. However, this method showed the weak correlation when applied in the measuring the changes of non-viable myocardium on the serial scans, which means that the caution will be needed to evaluate the changes on the serial monitoring.
Collapse
Affiliation(s)
- Kisoo Pahk
- Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea
| | - Sun Young Oh
- Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea
| | - Eugene Jeong
- Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea
| | - Sung Ho Lee
- Department of Cardiovascular Surgery, Korea University Anam Hospital, Seoul, South Korea
| | - Sang Keun Woo
- Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Jung Woo Yu
- Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul, South Korea
| | - Jae Gol Choe
- Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea
| | - Gi Jeong Cheon
- Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea ; Department of Nuclear Medicine, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 110-744 South Korea
| |
Collapse
|
39
|
Kuntner C. Kinetic modeling in pre-clinical positron emission tomography. Z Med Phys 2014; 24:274-85. [PMID: 24629308 DOI: 10.1016/j.zemedi.2014.02.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2013] [Revised: 02/11/2014] [Accepted: 02/11/2014] [Indexed: 12/11/2022]
Abstract
Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges off deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.
Collapse
Affiliation(s)
- Claudia Kuntner
- Biomedical Systems, Health & Environment Department, AIT Austrian Institute of Technology GmbH, Seibersdorf, Austria.
| |
Collapse
|
40
|
Wong KP, Zhang X, Huang SC. Improved derivation of input function in dynamic mouse [18F]FDG PET using bladder radioactivity kinetics. Mol Imaging Biol 2014; 15:486-96. [PMID: 23322346 DOI: 10.1007/s11307-013-0610-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE Accurate determination of the plasma input function (IF) is essential for absolute quantification of physiological parameters in positron emission tomography (PET). However, it requires an invasive and tedious procedure of arterial blood sampling that is challenging in mice because of the limited blood volume. In this study, a hybrid modeling approach is proposed to estimate the plasma IF of 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in mice using accumulated radioactivity in urinary bladder together with a single late-time blood sample measurement. METHODS Dynamic PET scans were performed on nine isoflurane-anesthetized male C57BL/6 mice after a bolus injection of [18F]FDG at the lateral caudal vein. During a 60- or 90-min scan, serial blood samples were taken from the femoral artery. Image data were reconstructed using filtered backprojection with computed tomography-based attenuation correction. Total accumulated radioactivity in the urinary bladder at late times was fitted to a renal compartmental model with the last blood sample and a one-exponential function that described the [18F]FDG clearance in blood. Multiple late-time blood sample estimates were calculated by the blood [18F]FDG clearance equation. A sum of four-exponentials was assumed for the plasma IF that served as a forcing function to all tissues. The estimated plasma IF was obtained by simultaneously fitting the [18F]FDG model to the time-activity curves (TACs) of liver and muscle and the forcing function to early (0-1 min) left-ventricle data (corrected for delay, dispersion, partial-volume effects, and erythrocyte uptake) and the late-time blood estimates. Using only the blood sample collected at the end of the study to estimate the IF and the use of liver TAC as an alternative IF were also investigated. RESULTS The area under the plasma IFs calculated for all studies using the hybrid approach was not significantly different from that using all blood samples. [18F]FDG uptake constants in brain, myocardium, skeletal muscle, and liver computed by the Patlak analysis using estimated and measured plasma IFs were in excellent agreement (slope∼1; R2>0.983). The IF estimated using only the last blood sample drawn at the end of the study and the use of liver TAC as the plasma IF provided less reliable results. CONCLUSIONS The estimated plasma IFs obtained with the hybrid method agreed well with those derived from arterial blood sampling. Importantly, the proposed method obviates the need of arterial catheterization, making it possible to perform repeated dynamic [18F]FDG PET studies on the same animal. Liver TAC is unsuitable as an input function for absolute quantification of [18F]FDG PET data.
Collapse
Affiliation(s)
- Koon-Pong Wong
- Department of Molecular and Medical Pharmacology, David Geffen School of Medicine at UCLA, Los Angeles, CA 90095, USA.
| | | | | |
Collapse
|
41
|
Hackett SL, Liu D, Chalkidou A, Marsden P, Landau D, Fenwick JD. Estimation of input functions from dynamic [18F]FLT PET studies of the head and neck with correction for partial volume effects. EJNMMI Res 2013; 3:84. [PMID: 24369816 PMCID: PMC4109699 DOI: 10.1186/2191-219x-3-84] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2013] [Accepted: 12/16/2013] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND We present a method for extracting arterial input functions from dynamic [18F]FLT PET images of the head and neck, directly accounting for the partial volume effect. The method uses two blood samples, for which the optimum collection times are assessed. METHODS Six datasets comprising dynamic PET images, co-registered computed tomography (CT) scans and blood-sampled input functions were collected from four patients with head and neck tumours. In each PET image set, a region was identified that comprised the carotid artery (outlined on CT images) and surrounding tissue within the voxels containing the artery. The time course of activity in the region was modelled as the sum of the blood-sampled input function and a compartmental model of tracer uptake in the surrounding tissue.The time course of arterial activity was described by a mathematical function with seven parameters. The parameters of the function and the compartmental model were simultaneously estimated, aiming to achieve the best match between the modelled and imaged time course of regional activity and the best match of the estimated blood activity to between 0 and 3 samples. The normalised root-mean-square (RMSnorm) differences and errors in areas under the curves (AUCs) between the measured and estimated input functions were assessed. RESULTS A one-compartment model of tracer movement to and from the artery best described uptake in the tissue surrounding the artery, so the final model of the input function and tissue kinetics has nine parameters to be estimated. The estimated and blood-sampled input functions agreed well when two blood samples, obtained at times between 2 and 8 min and between 8 and 60 min, were used in the estimation process (RMSnorm values of 1.1 ± 0.5 and AUC errors for the peak and tail region of the curves of 15% ± 9% and 10% ± 8%, respectively). A third blood sample did not significantly improve the accuracy of the estimated input functions. CONCLUSIONS Input functions for FLT-PET studies of the head and neck can be estimated well using a one-compartment model of tracer movement and TWO blood samples obtained after the peak in arterial activity.
Collapse
Affiliation(s)
- Sara L Hackett
- Gray Institute for Radiation Oncology and Biology, Department of Oncology,
University of Oxford, Oxford OX3 7DQ, UK
| | - Dan Liu
- Gray Institute for Radiation Oncology and Biology, Department of Oncology,
University of Oxford, Oxford OX3 7DQ, UK
| | - Anastasia Chalkidou
- PET Imaging Centre, Guys and St Thomas’ Hospital, King’s College
London, London SE1 7EH, UK
| | - Paul Marsden
- PET Imaging Centre, Guys and St Thomas’ Hospital, King’s College
London, London SE1 7EH, UK
| | - David Landau
- Department of Oncology, Guys and St Thomas’ Hospital, King’s College
London, London SE1 7EH, UK
| | - John D Fenwick
- Gray Institute for Radiation Oncology and Biology, Department of Oncology,
University of Oxford, Oxford OX3 7DQ, UK
| |
Collapse
|
42
|
Wei Mu, Zhe Chen, Xiaoqian Dai, Jie Tian. Noninvasive Estimation of the Input Function for Dynamic Mouse $^{\bf 18}$F-FDG MicroPET Studies. IEEE Trans Biomed Eng 2013; 60:3103-12. [DOI: 10.1109/tbme.2013.2267778] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
43
|
Whisenant JG, Peterson TE, Fluckiger JU, Tantawy MN, Ayers GD, Yankeelov TE. Reproducibility of static and dynamic (18)F-FDG, (18)F-FLT, and (18)F-FMISO MicroPET studies in a murine model of HER2+ breast cancer. Mol Imaging Biol 2013; 15:87-96. [PMID: 22644988 DOI: 10.1007/s11307-012-0564-0] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE The objective of this study is to determine the reproducibility of static 2-deoxy-2-[(18)F]fluoro-D-glucose ((18)F-FDG), 3'-deoxy-3'-[(18)F]fluorothymidine ((18)F-FLT), and [(18)F]-fluoromisonidazole ((18)F-FMISO) microPET measurements, as well as kinetic parameters returned from analyses of dynamic (18)F-FLT and (18)F-FMISO data. PROCEDURES HER2+ xenografts were established in nude mice. Dynamic data were acquired for 60 min, followed by a repeat injection and second scan 6 h later. Reproducibility was assessed for the percent-injected dose per gram (%ID/g) for each radiotracer, and with kinetic parameters (K (1) -k (4) , K ( i )) for (18)F-FLT and (18)F-FMISO. RESULTS The value needed to reflect a change in tumor physiology is given by the 95 % confidence interval (CI), which is ±14, ±5, and ±6 % for (18)F-FDG (n = 12), (18)F-FLT (n = 11), and (18)F-FMISO (n = 11) %ID/g, respectively. V ( d ) (=K (1) /k (2)), k (3), and K (FLT) are the most reproducible (18)F-FLT (n = 9) kinetic parameters, with 95 % CIs of ±18, ±10, and ±18 %, respectively. V ( d ) and K (FMISO) are the most reproducible (18)F-FMISO kinetic parameters (n = 7) with 95 % CIs of ±16 and ±14 %, respectively. CONCLUSIONS Percent-injected dose per gram measurements are reproducible and appropriate for detecting treatment-induced changes. Kinetic parameters have larger threshold values, but are potentially sufficiently reproducible to detect treatment response.
Collapse
Affiliation(s)
- Jennifer G Whisenant
- Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave. South, MCN AA-1105, Nashville, TN 37232-2675, USA
| | | | | | | | | | | |
Collapse
|
44
|
Zhong M, Kundu BK. Optimization of a Model Corrected Blood Input Function from Dynamic FDG-PET Images of Small Animal Heart In Vivo. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 2013; 60:3417-3422. [PMID: 24741130 PMCID: PMC3985393 DOI: 10.1109/tns.2013.2269032] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Quantitative evaluation of dynamic Positron Emission Tomography (PET) of mouse heart in vivo is challenging due to the small size of the heart and limited intrinsic spatial resolution of the PET scanner. Here, we optimized a compartment model which can simultaneously correct for spill over and partial volume effects for both blood pool and the myocardium, compute kinetic rate parameters and generate model corrected blood input function (MCBIF) from ordered subset expectation maximization - maximum a posteriori (OSEM-MAP) cardiac and respiratory gated 18F-FDG PET images of mouse heart with attenuation correction in vivo, without any invasive blood sampling. Arterial blood samples were collected from a single mouse to indicate the feasibility of the proposed method. In order to establish statistical significance, venous blood samples from n=6 mice were obtained at 2 late time points, when SP contamination from the tissue to the blood is maximum. We observed that correct bounds and initial guesses for the PV and SP coefficients accurately model the wash-in and wash-out dynamics of the tracer from mouse blood. The residual plot indicated an average difference of about 1.7% between the blood samples and MCBIF. The downstream rate of myocardial FDG influx constant, Ki (0.15±0.03 min-1), compared well with Ki obtained from arterial blood samples (P=0.716). In conclusion, the proposed methodology is not only quantitative but also reproducible.
Collapse
Affiliation(s)
- Min Zhong
- Department of Physics, Radiology and Medical Imaging, University of Virginia, VA 22903 USA (telephone: 434-260-0507, )
| | - Bijoy K Kundu
- Department of Radiology and Medical Imaging, University of Virginia, VA 22908 USA (telephone: 434-924-0284, )
| |
Collapse
|
45
|
Thorn SL, deKemp RA, Dumouchel T, Klein R, Renaud JM, Wells RG, Gollob MH, Beanlands RS, DaSilva JN. Repeatable noninvasive measurement of mouse myocardial glucose uptake with 18F-FDG: evaluation of tracer kinetics in a type 1 diabetes model. J Nucl Med 2013; 54:1637-44. [PMID: 23940301 DOI: 10.2967/jnumed.112.110114] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
UNLABELLED A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). METHODS Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. RESULTS The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. CONCLUSION The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.
Collapse
Affiliation(s)
- Stephanie L Thorn
- Division of Cardiology, National Cardiac PET Centre, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Zhong M, Alonso CE, Taegtmeyer H, Kundu BK. Quantitative PET imaging detects early metabolic remodeling in a mouse model of pressure-overload left ventricular hypertrophy in vivo. J Nucl Med 2013; 54:609-15. [PMID: 23426760 DOI: 10.2967/jnumed.112.108092] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
UNLABELLED We proposed that metabolic remodeling in the form of increased uptake of the myocardial glucose analog (18)F-FDG precedes and triggers the onset of severe contractile dysfunction in pressure-overload left ventricular hypertrophy in vivo. To test this hypothesis, we used a mouse model of transverse aortic constriction (TAC) together with PET and assessed serial changes in cardiac metabolism and function over 7 d. METHODS Scans of 16 C57BL/6 male mice were obtained using a small-animal PET device under sevoflurane anesthesia. A 10-min transmission scan was followed by a 60-min dynamic (18)F-FDG PET scan with cardiac and respiratory gating. Blood glucose levels were measured before and after the emission scan. TAC and sham surgeries were performed after baseline imaging. Osmotic mini pumps containing either propranolol (5 mg/kg/d) or vehicle alone were implanted subcutaneously at the end of surgery. Subsequent scans were taken at days 1 and 7 after surgery. A compartment model, in which the blood input function with spillover and partial-volume corrections and the metabolic rate constants in a 3-compartment model are simultaneously estimated, was used to determine the net myocardial (18)F-FDG influx constant, Ki. The rate of myocardial glucose utilization, rMGU, was also computed. Estimations of the ejection fractions were based on the high-resolution gated PET images. RESULTS Mice undergoing TAC surgery exhibited an increase in the Ki (580%) and glucose utilization the day after surgery, indicating early adaptive response. On day 7, the ejection fraction had decreased by 24%, indicating a maladaptive response. Average Ki increases were not linearly associated with increases in rMGU. Ki exceeded rMGU by 29% in the TAC mice. TAC mice treated with propranolol attenuated the rate of (18)F-FDG uptake, diminished mismatch between Ki and rMGU (9%), and rescued cardiac function. CONCLUSION Metabolic maladaptation precedes the onset of severe contractile dysfunction. Both are prevented by treatment with propranolol. The early detection of metabolic remodeling may offer a metabolic target for modulation of hypertrophy.
Collapse
Affiliation(s)
- Min Zhong
- Department of Physics, University of Virginia, Charlottesville, VA 22908, USA
| | | | | | | |
Collapse
|
47
|
Noninvasive estimation of the arterial input function in positron emission tomography imaging of cerebral blood flow. J Cereb Blood Flow Metab 2013; 33:115-21. [PMID: 23072748 PMCID: PMC3597366 DOI: 10.1038/jcbfm.2012.143] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Positron emission tomography (PET) with (15)O-labeled water can provide reliable measurement of cerebral blood flow (CBF). Quantification of CBF requires knowledge of the arterial input function (AIF), which is usually provided by arterial blood sampling. However, arterial sampling is invasive. Moreover, the blood generally is sampled at the wrist, which does not perfectly represent the AIF of the brain, because of the effects of delay and dispersion. We developed and validated a new noninvasive method to obtain the AIF directly by PET imaging of the internal carotid artery in a region of interest (ROI) defined by coregistered high-resolution magnetic resonance angiography. An ROI centered at the petrous portion of the internal carotid artery was defined, and the AIF was estimated simultaneously with whole brain blood flow. The image-derived AIF (IDAIF) method was validated against conventional arterial sampling. The IDAIF generated highly reproducible CBF estimations, generally in good agreement with the conventional technique.
Collapse
|
48
|
Xiong G, Paul C, Todica A, Hacker M, Bartenstein P, Böning G. Noninvasive image derived heart input function for CMRglc measurements in small animal slow infusion FDG PET studies. Phys Med Biol 2012; 57:8041-59. [PMID: 23160517 DOI: 10.1088/0031-9155/57/23/8041] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Absolute quantitation of the cerebral metabolic rate for glucose (CMRglc) can be obtained in positron emission tomography (PET) studies when serial measurements of the arterial [(18)F]-fluoro-deoxyglucose (FDG) input are available. Since this is not always practical in PET studies of rodents, there has been considerable interest in defining an image-derived input function (IDIF) by placing a volume of interest (VOI) within the left ventricle of the heart. However, spill-in arising from trapping of FDG in the myocardium often leads to progressive contamination of the IDIF, which propagates to underestimation of the magnitude of CMRglc. We therefore developed a novel, non-invasive method for correcting the IDIF without scaling to a blood sample. To this end, we first obtained serial arterial samples and dynamic FDG-PET data of the head and heart in a group of eight anaesthetized rats. We fitted a bi-exponential function to the serial measurements of the IDIF, and then used the linear graphical Gjedde-Patlak method to describe the accumulation in myocardium. We next estimated the magnitude of myocardial spill-in reaching the left ventricle VOI by assuming a Gaussian point-spread function, and corrected the measured IDIF for this estimated spill-in. Finally, we calculated parametric maps of CMRglc using the corrected IDIF, and for the sake of comparison, relative to serial blood sampling from the femoral artery. The uncorrected IDIF resulted in 20% underestimation of the magnitude of CMRglc relative to the gold standard arterial input method. However, there was no bias with the corrected IDIF, which was robust to the variable extent of myocardial tracer uptake, such that there was a very high correlation between individual CMRglc measurements using the corrected IDIF with gold-standard arterial input results. Based on simulation, we furthermore find that electrocardiogram-gating, i.e. ECG-gating is not necessary for IDIF quantitation using our approach.
Collapse
Affiliation(s)
- Guoming Xiong
- Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich, Munich, Germany.
| | | | | | | | | | | |
Collapse
|
49
|
Erlandsson K, Buvat I, Pretorius PH, Thomas BA, Hutton BF. A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology. Phys Med Biol 2012; 57:R119-59. [DOI: 10.1088/0031-9155/57/21/r119] [Citation(s) in RCA: 320] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
50
|
Zheng X, Wen L, Yu SJ, Huang SC, Feng DD. A study of non-invasive Patlak quantification for whole-body dynamic FDG-PET studies of mice. Biomed Signal Process Control 2012; 7:438-446. [PMID: 22956982 DOI: 10.1016/j.bspc.2011.11.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Physiological changes in dynamic PET images can be quantitatively estimated by kinetic modeling technique. The process of PET quantification usually requires an input function in the form of a plasma-time activity curve (PTAC), which is generally obtained by invasive arterial blood sampling. However, invasive arterial blood sampling poses many challenges especially for small animal studies, due to the subjects' limited blood volume and small blood vessels. A simple non-invasive quantification method based on Patlak graphical analysis (PGA) has been recently proposed to use a reference region to derive the relative influx rate for a target region without invasive blood sampling, and evaluated by using the simulation data of human brain FDG-PET studies. In this study, the non-invasive Patlak (nPGA) method was extended to whole-body dynamic small animal FDG-PET studies. The performance of nPGA was systematically investigated by using experimental mouse studies and computer simulations. The mouse studies showed high linearity of relative influx rates between the nPGA and PGA for most pairs of reference and target regions, when an appropriate underlying kinetic model was used. The simulation results demonstrated that the accuracy of the nPGA method was comparable to that of the PGA method, with a higher reliability for most pairs of reference and target regions. The results proved that the nPGA method could provide a non-invasive and indirect way for quantifying the FDG kinetics of tumor in small animal studies.
Collapse
Affiliation(s)
- Xiujuan Zheng
- School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | | | | | | | | |
Collapse
|