1
|
Aherrera A, Lin JJ, Chen R, Tehrani M, Schultze A, Borole A, Tanda S, Goessler W, Rule AM. Metal Concentrations in E-Cigarette Aerosol Samples: A Comparison by Device Type and Flavor. ENVIRONMENTAL HEALTH PERSPECTIVES 2023; 131:127004. [PMID: 38048100 PMCID: PMC10695266 DOI: 10.1289/ehp11921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 10/18/2023] [Accepted: 11/06/2023] [Indexed: 12/05/2023]
Abstract
BACKGROUND The rapid evolution of electronic cigarette (e-cigarette) products warrants surveillance of the differences in exposure across device types-modifiable devices (MODs), cartridge ("pod")-containing devices (PODs), disposable PODs (d-PODs)-and flavors of the products available on the market. OBJECTIVE This study aimed to measure and compare metal aerosol concentrations by device type and common flavors. METHODS We collected aerosol from 104 MODs, 67 PODs (four brands: JUUL, Bo, Suorin, PHIX), and 23 d-PODs (three brands: ZPOD, Bidi, Stig) via droplet deposition in a series of conical pipette tips. Metals and metalloids [aluminum (Al), arsenic (As), cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn)] were measured using inductively coupled plasma mass spectrometry (ICP-MS), results were log-transformed for statistical analysis, and concentrations are reported in aerosol units (mg / m 3 ). RESULTS Of the 12 elements analyzed, concentrations were statistically significantly higher in MOD devices, except for Co and Ni, which were higher in PODs and d-PODs. Of the POD brands analyzed, PHIX had the highest median concentrations among four metals (Al, Ni, Pb, and Sn) compared to the rest of the POD brands. According to POD flavor, seven metals were three to seven orders of magnitude higher in tobacco-flavored aerosol compared to those in mint and mango flavors. Among the d-POD brands, concentrations of four metals (Al, Cu, Ni, and Pb) were higher in the ZPOD brand than in Bidi Stick and Stig devices. According to d-POD flavor, only Cr concentrations were found to be statistically significantly higher in mint than tobacco-flavored d-PODs. DISCUSSION We observed wide variability in aerosol metal concentrations within and between the different e-cigarette device types, brands, and flavors. Overall, MOD devices generated aerosols with higher metal concentrations than PODs and d-PODs, and tobacco-flavored aerosols contained the highest metal concentrations. Continued research is needed to evaluate additional factors (i.e., nicotine type) that contribute to metal exposure from new and emerging e-cigarette devices in order to inform policy. https://doi.org/10.1289/EHP11921.
Collapse
Affiliation(s)
- Angela Aherrera
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
- Division of Pediatric Pulmonary Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Joyce Jy Lin
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Rui Chen
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Mina Tehrani
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Andrew Schultze
- Department of Biochemistry, Ithaca College School of Humanities and Sciences, Ithaca, New York, USA
| | - Aryan Borole
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Stefan Tanda
- Institute of Chemistry, University of Graz, Graz, Austria
| | | | - Ana M. Rule
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| |
Collapse
|
2
|
Ma T, Chen H, Liao YP, Li J, Wang X, Li L, Li J, Zhu Y, Xia T. Differential Toxicity of Electronic Cigarette Aerosols Generated from Different Generations of Devices In Vitro and In Vivo. ENVIRONMENT & HEALTH (WASHINGTON, D.C.) 2023; 1:315-323. [PMID: 38028320 PMCID: PMC10660664 DOI: 10.1021/envhealth.3c00099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/21/2023] [Accepted: 08/22/2023] [Indexed: 12/01/2023]
Abstract
Electronic cigarettes (e-cigs) have become increasingly popular, especially among youth, raising concerns about their potential health risks. JUUL and Tank devices are two common types of e-cigs that deliver aerosols with varying nicotine levels and flavors. However, the differences in the aerosols generated from different devices and their corresponding cytotoxicity and pulmonary injury effects remain poorly understood. This study addresses these knowledge gaps by characterizing the aerosols of JUUL and Tank e-cig devices and testing their toxic effects on THP-1 and BEAS-2B human cell lines as well as the C57BL/6J mouse model. In our study, the lower-voltage device, the 3.7 V JUUL generates 2.72 mg/puff aerosols by using e-liquid containing 3% nicotine salt (i.e., nicotine benzoate), which is less than the 11.06 mg/puff aerosols generated by the 7.5 V Tank using e-liquid containing 2.4% freebase nicotine. Yet, the cytotoxicity results reveal that JUUL aerosols induced higher toxicity and increased production of pro-inflammation cytokines compared to Tank aerosols per puff. Additionally, we observed that JUUL induced more severe pulmonary inflammation and DNA damage compared to Tank after normalizing for cotinine, a nicotine metabolite, in vivo. Our findings suggest that the device design plays a more important role in e-cig aerosol-induced toxicity than the composition of the e-liquid or voltage. These results provide valuable insights into the health risks associated with various electronic-cig devices and offer an approach for evaluating them.
Collapse
Affiliation(s)
- Tiancong Ma
- Division
of Nanomedicine, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-1772, United
States
- Department
of Environmental Health Sciences, Jonathan and Karin Fielding School
of Public Health, University of California,
Los Angeles, Los Angeles, California 90095-1772, United States
| | - Haoxuan Chen
- Department
of Environmental Health Sciences, Jonathan and Karin Fielding School
of Public Health, University of California,
Los Angeles, Los Angeles, California 90095-1772, United States
| | - Yu-Pei Liao
- Division
of Nanomedicine, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-1772, United
States
| | - Jiulong Li
- Division
of Nanomedicine, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-1772, United
States
| | - Xiang Wang
- Division
of Nanomedicine, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-1772, United
States
| | - Liqiao Li
- Department
of Environmental Health Sciences, Jonathan and Karin Fielding School
of Public Health, University of California,
Los Angeles, Los Angeles, California 90095-1772, United States
| | - Jing Li
- Department
of Environmental Health Sciences, Jonathan and Karin Fielding School
of Public Health, University of California,
Los Angeles, Los Angeles, California 90095-1772, United States
| | - Yifang Zhu
- Department
of Environmental Health Sciences, Jonathan and Karin Fielding School
of Public Health, University of California,
Los Angeles, Los Angeles, California 90095-1772, United States
| | - Tian Xia
- Division
of Nanomedicine, Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California 90095-1772, United
States
| |
Collapse
|
3
|
Kolaczyk K, Jiang H. Photometric Monitoring of Electronic Cigarette Puff Topography. SENSORS (BASEL, SWITZERLAND) 2023; 23:8220. [PMID: 37837050 PMCID: PMC10575377 DOI: 10.3390/s23198220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 09/29/2023] [Accepted: 10/01/2023] [Indexed: 10/15/2023]
Abstract
To study and monitor the adverse health consequences of using electronic cigarettes, a user's puff topography, which are quantification parameters of the user's vaping habits, plays a central role. In this work, we introduce a topography sensor to measure the mass of total particulate matter generated in every puff and to estimate the nicotine yield. The sensor is compact and low-cost, and is integrated into the electronic cigarette device to promptly and conveniently monitor the user's daily puff topography. The topography sensor is comprised of a photometric sensor and a pressure sensor. The photometric sensor measures the mass concentration of the aerosol, based on scattering of near-infrared light from airborne particles, while the pressure sensor measures the flow rate. The topography sensor was tested under various conditions including a wide range of atomizer power, puff duration, and inhalation pressure. The sensor's accuracy was validated by comparing the sensor's readings with reference measurements, and the results matched closely with the trends reported by existing studies on electronic cigarettes. An example application for tracking a user's puff topography was also demonstrated. Our topography sensor holds great promise in mitigating the health risks of vaping, and in promoting quality control of electronic cigarette products.
Collapse
|
4
|
Faria GM, Galvão TD, Parreira PS, Melquiades FL. Metals quantification in e-cigarettes liquids by Total Reflection X-ray Spectrometry. Appl Radiat Isot 2023; 200:110964. [PMID: 37523865 DOI: 10.1016/j.apradiso.2023.110964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 07/25/2023] [Accepted: 07/26/2023] [Indexed: 08/02/2023]
Abstract
Electronic cigarettes (e-cig) have gained popularity around the world and its health risks demands more research. This study aims at characterizing e-cig liquids (e-liquids) and its constituents by Total Reflection X-ray Spectrometry (TXRF). The internal standard method was the quantification procedure employed. The spectrometer's performance was evaluated with one certified reference material and spiked samples. It was possible to quantify K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, and Pb in the e-liquids. Concentrations above the limit for potable water were found in 10 out of 38 samples. Principal component analysis was useful for identifying toxic samples. TXRF is a promising technique for e-liquids evaluation due to its simplicity and performance.
Collapse
Affiliation(s)
- Gabriel Minto Faria
- Applied Nuclear Physics Laboratory, Universidade Estadual de Londrina (UEL), 86057-970, Londrina, PR, Brazil
| | - Tiago Dutra Galvão
- Instituto de Desenvolvimento Rural do Paraná - IAPAR-EMATER, Área de Agrometeorologia, Fisiologia Vegetal e Tecnologia de Alimentos, 86047-902, Londrina, PR, Brazil
| | - Paulo Sergio Parreira
- Applied Nuclear Physics Laboratory, Universidade Estadual de Londrina (UEL), 86057-970, Londrina, PR, Brazil
| | - Fábio Luiz Melquiades
- Applied Nuclear Physics Laboratory, Universidade Estadual de Londrina (UEL), 86057-970, Londrina, PR, Brazil.
| |
Collapse
|
5
|
Haworth-Duff A, Parkes GMB, Reed NJ. A simple approach to analysing trace metals in aerosols produced by e-cigarettes. Drug Test Anal 2023; 15:1084-1090. [PMID: 36445210 DOI: 10.1002/dta.3416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 09/27/2022] [Accepted: 11/22/2022] [Indexed: 12/03/2022]
Abstract
Electronic cigarettes are a relatively new alternative to cigarettes, which have been marketed as being safer for users than conventional cigarettes. However, they may still result in inhalation of potentially toxic or carcinogenic substances, including metals produced by the heating element. This study looked at the levels of trace metals being produced by different atomizers used in e-cigarettes using a sample introduction technique based on the collection of aerosols produced by e-cigarettes in nitric acid, using glass midget impingers. Collected metals were then identified using an inductively coupled plasma-mass spectrometer (ICP-MS), which allowed detection in the low ppb range. Results obtained showed considerable variation in the levels of metals between both manufacturers of atomizers and also between different batches of coils. This variation is likely to be even greater if the ability of users to customise some types of e-cigarettes is considered. Although there are limitations in terms of possible interferences from other metallic components in the e-cigarettes, the findings suggest the proposed method could be of use in investigating the risk of inhalation of toxic metals from e-cigarette use.
Collapse
Affiliation(s)
- Adam Haworth-Duff
- Department of Electrical Engineering and Electronics, School of Electrical Engineering, Electronics and Computer Science, University of Liverpool, Merseyside, UK
| | - Gareth M B Parkes
- Department of Chemical and Forensic Sciences, School of Applied Sciences, University of Huddersfield, West Yorkshire, UK
| | - Natasha J Reed
- Department of Chemical and Forensic Sciences, School of Applied Sciences, University of Huddersfield, West Yorkshire, UK
| |
Collapse
|
6
|
Zhang Q, Wen C. The risk profile of electronic nicotine delivery systems, compared to traditional cigarettes, on oral disease: a review. Front Public Health 2023; 11:1146949. [PMID: 37255760 PMCID: PMC10226679 DOI: 10.3389/fpubh.2023.1146949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/14/2023] [Indexed: 06/01/2023] Open
Abstract
The use of electronic nicotine delivery systems (ENDS) has exploded, especially among teenagers and new smokers, amid widespread awareness of the dangers of traditional tobacco and restrictions on smoking. However, the risk effects of ENDS on physical health, especially oral health, are still ambiguous. The purpose of this study was to review the available evidence on risks of ENDS on oral health, and compares the differences between ENDS and traditional cigarettes. For heavy smokers, transferring the addiction of tobacco to ENDS can be less harmful to periodontal condition and physical health but is not completely without risk. The components of ENDS vapor have cytotoxic, genotoxic, and carcinogenic properties, and its usage may be associated with a wide range of oral health sequelae. The chemicals in ENDS increase the susceptibility to tooth decay, increase the risk of periodontal disease, peri-implant, and oral mucosal lesions. Nicotine aerosols from ENDS can be a potential risk factor for oral cancer due to the presence of carcinogenic components. Compared to smoking traditional cigarettes, the harm associated with ENDS use may be underestimated due to the reduced ability to control vaping behavior, ease of ENDS access, fewer vaping area restrictions, and better taste. Currently, the available evidence suggests that ENDS may be a safer alternative to traditional tobacco products. Though most oral symptoms experienced by ENDS users are relatively mild and temporary compared to traditional cigarettes, the dangers of ENDS still exist. However, further research with longer follow-up periods is required to establish the long-term safety of ENDS.
Collapse
Affiliation(s)
- Qing Zhang
- Department of Nosocomial Infection Control, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China
| | - Cai Wen
- Department of Oral Implantology, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
- Department of VIP Dental Service, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
- Luzhou Key Laboratory of Oral and Maxillofacial Reconstruction and Regeneration, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, Sichuan, China
- Institute of Stomatology, Southwest Medical University, Luzhou, Sichuan, China
| |
Collapse
|
7
|
Alcantara C, Chaparro L, Zagury GJ. Occurrence of metals in e-cigarette liquids: Influence of coils on metal leaching and exposure assessment. Heliyon 2023; 9:e14495. [PMID: 36950607 PMCID: PMC10025154 DOI: 10.1016/j.heliyon.2023.e14495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 03/08/2023] [Accepted: 03/08/2023] [Indexed: 03/12/2023] Open
Abstract
Electronic cigarettes are generally recognized as a safer alternative than conventional cigarettes. Nevertheless, previous research suggests metal (loid) leaching due to coil contact, potentially transferring to the e-liquid and its aerosolized form. In this study, Cr, Cd, Ni, and Pb levels were measured by inductively coupled plasma mass spectrometry (ICP-MS) on 17 samples of e-liquids with different chemical properties (e.g., pH, nicotine content, flavoring, free-base, and nicotine salts). Twelve e-liquids were then put in contact with 36-gauge Kanthal A-1, Nichrome 80, Stainless steel 317 L and disposable coils such as Juul, and Aspire BVC for three days at 200-250 °C for 1 h each day. Metal levels expressed as mean (standard deviation) metal concentration, were below detection (Cd) to very low in bottle samples (Ni ≤ 76 (18); Pb ≤ 16 (1.5); and Cr ≤ 386 (15.6) μg/kg). In the coil extracts, varying concentrations of the same metal (loid) were found, indicating that metal leaching capacity may differ per sample. All samples contained Ni and Cr, followed by Pb to a much lesser extent. Cd levels were mostly below detection limits. Coil + e-liquid combinations with the highest Ni, Cr, and Pb concentrations were: Aspire BVC + Melon 0 mg/mL: Ni = 1.22 E+04 (281); Aspire BVC + Hit Nicotine 40 mg/mL: Cr = 864 (116); and Nichrome 80 + Melon 0 mg/mL: Pb = 56 (5) μg/kg. Overall, results suggest that nicotine salts at 40 mg/mL enhance Cr and Ni transfer. Stainless steel 317 L released very low metal concentrations. A conservative screening level risk characterization showed that 10.5% and 3.5% of the coil extracts may exceed Ni and Cr (III) safe concentrations, respectively. In the aerosol phase, 8.8% of samples might be above Ni equivalent daily dose for chronic exposure and 1.8% for intermediate exposure. Further studies on coil metal leaching could aid in establishing coil manufacturing regulations.
Collapse
Affiliation(s)
- Claudia Alcantara
- Department of Civil, Geological and Mining Engineering, Polytechnique Montréal (QC), H3C 3A7, Canada
| | - Laura Chaparro
- Les Laboratoires Vaporus Inc., 9704 Trans Canada Route, Saint-Laurent (QC), H4S 1V9, Canada
| | - Gerald J. Zagury
- Department of Civil, Geological and Mining Engineering, Polytechnique Montréal (QC), H3C 3A7, Canada
- Corresponding author. Department of Civil, Geological and Mining Engineering Polytechnique Montréal P.O. Box 6079, Station Centre-Ville Montréal, (QC), Canada, H3C 3A7 .
| |
Collapse
|
8
|
Holt AK, Poklis JL, Peace MR. The history, evolution, and practice of cannabis and E-cigarette industries highlight necessary public health and public safety considerations. JOURNAL OF SAFETY RESEARCH 2023; 84:192-203. [PMID: 36868647 PMCID: PMC10829760 DOI: 10.1016/j.jsr.2022.10.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 05/29/2022] [Accepted: 10/25/2022] [Indexed: 06/18/2023]
Affiliation(s)
- Alaina K Holt
- Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, United States; Integrative Life Sciences Doctoral Program, Virginia Commonwealth University, Richmond, VA, United States.
| | - Justin L Poklis
- Department of Pharmacology & Toxicology, Virginia Commonwealth University, Richmond, VA, United States.
| | - Michelle R Peace
- Department of Forensic Science, Virginia Commonwealth University, Richmond, VA, United States.
| |
Collapse
|
9
|
Zhang Q, Jeon J, Goldsmith T, Black M, Greenwald R, Wright C. Characterization of an Electronic Nicotine Delivery System (ENDS) Aerosol Generation Platform to Determine Exposure Risks. TOXICS 2023; 11:99. [PMID: 36850974 PMCID: PMC9967066 DOI: 10.3390/toxics11020099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 01/13/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
Evaluating vaping parameters that influence electronic nicotine delivery system (ENDS) emission profiles and potentially hazardous exposure levels is essential to protecting human health. We developed an automated multi-channel ENDS aerosol generation system (EAGS) for characterizing size-resolved particle emissions across pod- and mod-type devices using real-time monitoring instruments, an exposure chamber, and vaping parameters including different ventilation rates, device type and age, e-liquid formulation, and atomizer setup. Results show the ENDS device type, e-liquid flavoring, and nicotine content can affect particle emissions. In general, pod-type devices have unimodal particle size distributions and higher number emissions, while mod-type devices have bimodal size distributions and higher mass emissions. For pod-type devices, later puff fractions emit lower aerosols, which is potentially associated with the change of coil resistance and power during ageing. For a mod-type device, an atomizer with a lower resistance coil and higher power generates larger particle emissions than an atomizer with a greater resistance coil and lower power. The unventilated scenario produces higher particle emission factors, except for particle mass emission from pod-type devices. The data provided herein indicate the EAGS can produce realistic and reproducible puff profiles of pod- and mod-type ENDS devices and therefore is a suitable platform for characterizing ENDS-associated exposure risks.
Collapse
Affiliation(s)
- Qian Zhang
- Chemical Insights Research Institute, UL Research Institutes, Marietta, GA 30067, USA
| | - Jennifer Jeon
- Chemical Insights Research Institute, UL Research Institutes, Marietta, GA 30067, USA
| | - Travis Goldsmith
- Department of Physiology and Pharmacology, West Virginia University/IEStechno, Morgantown, WV 26505, USA
| | - Marilyn Black
- Chemical Insights Research Institute, UL Research Institutes, Marietta, GA 30067, USA
| | - Roby Greenwald
- School of Public Health, Georgia State University, Atlanta, GA 30303, USA
| | - Christa Wright
- Chemical Insights Research Institute, UL Research Institutes, Marietta, GA 30067, USA
| |
Collapse
|
10
|
Soulet S, Sussman RA. A Critical Review of Recent Literature on Metal Contents in E-Cigarette Aerosol. TOXICS 2022; 10:toxics10090510. [PMID: 36136475 PMCID: PMC9506048 DOI: 10.3390/toxics10090510] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 08/24/2022] [Accepted: 08/26/2022] [Indexed: 05/23/2023]
Abstract
The inhalation of metallic compounds in e-cigarette (EC) aerosol emissions presents legitimate concerns of potential harms for users. We provide a critical review of laboratory studies published after 2017 on metal contents in EC aerosol, focusing on the consistency between their experimental design, real life device usage and appropriate evaluation of exposure risks. All experiments reporting levels above toxicological markers for some metals (e.g., nickel, lead, copper, manganese) exhibited the following experimental flaws: (i) high powered sub-ohm tank devices tested by means of puffing protocols whose airflows and puff volumes are conceived and appropriate for low powered devices; this testing necessarily involves overheating conditions that favor the production of toxicants and generate aerosols that are likely repellent to human users; (ii) miscalculation of exposure levels from experimental outcomes; (iii) pods and tank devices acquired months and years before the experiments, so that corrosion effects cannot be ruled out; (iv) failure to disclose important information on the characteristics of pods and tank devices, on the experimental methodology and on the resulting outcomes, thus hindering the interpretation of results and the possibility of replication. In general, low powered devices tested without these shortcomings produced metal exposure levels well below strict reference toxicological markers. We believe this review provides useful guidelines for a more objective risk assessment of EC aerosol emissions and signals the necessity to upgrade current laboratory testing standards.
Collapse
Affiliation(s)
| | - Roberto A. Sussman
- Institute of Nuclear Sciences, National Autonomous University of Mexico, Mexico City 04510, Mexico
| |
Collapse
|
11
|
Vivarelli F, Granata S, Rullo L, Mussoni M, Candeletti S, Romualdi P, Fimognari C, Cruz-Chamorro I, Carrillo-Vico A, Paolini M, Canistro D. On the toxicity of e-cigarettes consumption: Focus on pathological cellular mechanisms. Pharmacol Res 2022; 182:106315. [PMID: 35724819 DOI: 10.1016/j.phrs.2022.106315] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/09/2022] [Accepted: 06/14/2022] [Indexed: 10/18/2022]
Abstract
Tobacco smoking remains without a doubt one of the leading causes of premature death worldwide. In combination with conventional protocols for smoking cessation, e-cigarettes have been proposed as a useful tool to quit smoking. Advertised as almost free of toxic effects, e-cigarettes have rapidly increased their popularity, becoming a sought-after device, especially among young people. Recently some health concerns about e-cigarette consumption are being raised. It is well known that they can release several toxic compounds, some of which are carcinogenic to humans, and emerging results are now outlining the risks related to the onset of respiratory and cardiovascular diseases and even cancer. The present review shows the emerging evidence about the role of technical components of the devices, the e-liquid composition as well as customization by consumers. The primary topics we discuss are the main toxicological aspects associated with e-cigarette consumption, focusing on the molecular pathways involved. Here it will be shown how exposure to e-cigarette aerosol induces stress/mitochondrial toxicity, DNA breaks/fragmentation following the same pathological pathways triggered by tobacco smoke, including the deregulation of molecular signalling axis associated with cancer progression and cell migration. Risk to fertility and pregnancy, as well as cardiovascular risk associated with e-cigarette use, have also been reported.
Collapse
Affiliation(s)
- Fabio Vivarelli
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy.
| | - Silvia Granata
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy; Department of Medicine and Surgery - University of Milano - Bicocca
| | - Laura Rullo
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
| | - Matilde Mussoni
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
| | - Sanzio Candeletti
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
| | - Patrizia Romualdi
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
| | - Carmela Fimognari
- Department for Life Quality Studies, Alma Mater Studiorum-University of Bologna, Corso d'Augusto 237, 47921 Rimini, Italy
| | - Ivan Cruz-Chamorro
- Instituto de Biomedicina de Sevilla, IBiS (Universidad de Sevilla, HUVR, Junta de Andalucía, CSIC), 41013 Seville, Spain; Departamento de Bioquímica Médica y Biología Molecular e Inmunología, Universidad de Sevilla, 41009 Seville, Spain
| | - Antonio Carrillo-Vico
- Instituto de Biomedicina de Sevilla, IBiS (Universidad de Sevilla, HUVR, Junta de Andalucía, CSIC), 41013 Seville, Spain; Departamento de Bioquímica Médica y Biología Molecular e Inmunología, Universidad de Sevilla, 41009 Seville, Spain
| | - Moreno Paolini
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy.
| | - Donatella Canistro
- Department of Pharmacy and Biotechnology, Alma Mater Studiorum-University of Bologna, Via Irnerio 48, 40126 Bologna, Italy
| |
Collapse
|
12
|
Mechanistic Effects of E-Liquids on Biofilm Formation and Growth of Oral Commensal Streptococcal Communities: Effect of Flavoring Agents. Dent J (Basel) 2022; 10:dj10050085. [PMID: 35621538 PMCID: PMC9139693 DOI: 10.3390/dj10050085] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/21/2022] [Accepted: 05/11/2022] [Indexed: 02/04/2023] Open
Abstract
Background: Vaping has become a global health concern. As research continues, more studies are beginning to question the relative safety of E-liquid flavoring additives. The oral cavity is the first site of exposure to E-liquid aerosol, making it critical for investigation. Because of the importance of commensal bacterial biofilms for oral health, we sought to explore the effects of E-liquids ± flavors on the formation and growth of single- and multi-species biofilms and to investigate the mechanism of inhibition. Methods: Quantitative and confocal biofilm analysis, death curves, and colony-forming units (CFU) were evaluated with flavorless and flavored (tobacco, menthol, cinnamon, strawberry, blueberry) E-liquids using four strains of oral commensal bacteria (Streptococcus gordonii, Streptococcus intermedius, Streptococcus mitis, and Streptococcus oralis). Results: All flavoring agents show a dose-dependent inhibition in the growth of single-species and multi-species biofilms. Furthermore, CFUs, death curves, and light microscopy show that flavoring agents have a bactericidal mode of inhibition on the growth of these oral streptococci. Conclusions: These results show that flavored, rather than unflavored, E-liquids are more detrimental to biofilm formation and growth of oral commensal bacteria. Consequently, E-liquid flavorings agents could pose risks to the oral microenvironment, and by extension, to systemic health.
Collapse
|
13
|
Jităreanu A, Cara IG, Sava A, Mârțu I, Caba IC, Agoroaei L. The Impact of the Storage Conditions and Type of Clearomizers on the Increase of Heavy Metal Levels in Electronic Cigarette Liquids Retailed in Romania. TOXICS 2022; 10:toxics10030126. [PMID: 35324751 PMCID: PMC8950552 DOI: 10.3390/toxics10030126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 02/22/2022] [Accepted: 03/03/2022] [Indexed: 11/30/2022]
Abstract
The growing popularity of electronic cigarettes has raised several public health concerns, including the risks associated with heavy metals exposure via e-liquids and vapors. The purpose of this study was to determine, using atomic absorption spectrometry, the concentrations of Pb, Ni, Zn, and Co in some commercially available e-liquid samples from Romania immediately after purchase and after storage in clearomizers. Lead and zinc were found in all investigated samples before storage. The initial concentrations of Pb ranged from 0.13 to 0.26 mg L−1, while Zn concentrations were between 0.04 and 0.07 mg L−1. Traces of nickel appeared in all investigated e-liquids before storage but in very small amounts (0.01–0.02 mg L−1). Co was below the detection limits. We investigated the influence of the storage period (1, 3, and 5 days), storage temperature (22 °C and 40 °C), and type of clearomizer. In most cases, the temperature rise and storage period increase were associated with higher concentrations of heavy metals. This confirms that storage conditions can affect metal transfer and suggests that the temperature of storage is another parameter that can influence this phenomenon.
Collapse
Affiliation(s)
- Alexandra Jităreanu
- Department of Toxicology, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iași, Romania; (A.J.); (I.-C.C.); (L.A.)
| | - Irina Gabriela Cara
- Research Institute for Agriculture and Environment, “Ion Ionescu de la Brad” University of Life Sciences, 700115 Iasi, Romania
- Correspondence:
| | - Alexandru Sava
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iași, Romania;
| | - Ioana Mârțu
- Department of Dental Technology, Faculty of Dental Medicine, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iași, Romania;
| | - Ioana-Cezara Caba
- Department of Toxicology, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iași, Romania; (A.J.); (I.-C.C.); (L.A.)
| | - Luminița Agoroaei
- Department of Toxicology, Faculty of Pharmacy, University of Medicine and Pharmacy “Grigore T. Popa”, 700115 Iași, Romania; (A.J.); (I.-C.C.); (L.A.)
| |
Collapse
|
14
|
Palazzolo DL, Caudill J, Baron J, Cooper K. Fabrication and Validation of an Economical, Programmable, Dual-Channel, Electronic Cigarette Aerosol Generator. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph182413190. [PMID: 34948804 PMCID: PMC8703563 DOI: 10.3390/ijerph182413190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/06/2021] [Accepted: 12/09/2021] [Indexed: 11/16/2022]
Abstract
Vaping (inhalation of electronic cigarette-generated aerosol) is a public health concern. Due to recent spikes in adolescent use of electronic cigarettes (ECIGs) and vaping-induced illnesses, demand for scientific inquiry into the physiological effects of electronic cigarette (ECIG) aerosol has increased. For such studies, standardized and consistent aerosol production is required. Many labs generate aerosol by manually activating peristaltic pumps and ECIG devices simultaneously in a predefined manner. The tedium involved with this process (large puff number over time) and risk of error in keeping with puff topography (puff number, duration, interval) are less than optimal. Furthermore, excess puffing on an ECIG device results in battery depletion, reducing aerosol production, and ultimately, its chemical and physical nature. While commercial vaping machines are available, the cost of these machines is prohibitive to many labs. For these reasons, an economical and programmable ECIG aerosol generator, capable of generating aerosol from two atomizers simultaneously, was fabricated, and subsequently validated. Validation determinants include measurements of atomizer temperatures (inside and outside), electrical parameters (current, resistance and power) of the circuitry, aerosol particle distribution (particle counts and mass concentrations) and aerosol delivery (indexed by nicotine recovery), all during stressed conditions of four puffs/minute for 75 min (i.e., 300 puffs). Validation results indicate that the ECIG aerosol generator is better suited for experiments involving ≤100 puffs. Over 100 puffs, the amount of variation in the parameters measured tends to increase. Variations between channels are generally higher than variations within a channel. Despite significant variations in temperatures, electrical parameters, and aerosol particle distributions, both within and between channels, aerosol delivery remains remarkably stable for up to 300 puffs, yielding over 25% nicotine recovery for both channels. In conclusion, this programmable, dual-channel ECIG aerosol generator is not only affordable, but also allows the user to control puff topography and eliminate battery drain of ECIG devices. Consequently, this aerosol generator is valid, reliable, economical, capable of using a variety of E-liquids and amenable for use in a vast number of studies investigating the effects of ECIG-generated aerosol while utilizing a multitude of puffing regimens in a standardized manner.
Collapse
Affiliation(s)
- Dominic L. Palazzolo
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA; (J.C.); (J.B.)
- Correspondence:
| | - Jordan Caudill
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA; (J.C.); (J.B.)
| | - James Baron
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA; (J.C.); (J.B.)
| | - Kevin Cooper
- Department of Chemistry and Physics, School of Mathematics & Sciences, Lincoln Memorial University, Harrogate, TN 37752, USA;
| |
Collapse
|
15
|
Kubachka KM, Wilson RA. Elemental Analysis of Tetrahydrocannabinol and Nicotine E-Liquids Related to EVALI. ACS OMEGA 2021; 6:32090-32100. [PMID: 34870030 PMCID: PMC8638013 DOI: 10.1021/acsomega.1c04868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Accepted: 10/27/2021] [Indexed: 06/13/2023]
Abstract
During the e-cigarette, or vaping, product use-associated lung injury (EVALI) investigation, the U.S. FDA's Forensic Chemistry Center (FCC) received numerous sample submissions from various states and other sources. Many of these products were linked directly to patients, while others were not; both categories included used and unused products. Elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS) preceded by microwave-assisted decomposition was carried out on the cartridge contents of 65 of these submitted samples. Challenges encountered included limited sample, high sample viscosity, and adhesion, which necessitated sample preparation techniques not commonly used during routine elemental analysis. The elemental concentrations of contaminants including Pb, As, Cd, Cr, Ni, Cu, and Sn in tetrahydrocannabinol (THC) e-liquids associated with EVALI were determined. Nicotine e-liquid samples collected alongside the THC e-liquid samples were analyzed in tandem during method development. Several THC e-liquid samples contained Pb greater than 0.5 μg/g, while others had part per million levels of Ni, Cu, and/or Cr. This study presents the first detailed report of elemental concentrations in multiple THC e-liquid samples including those from informal/illicit sources and also delves into the method considerations needed for testing a viscous, hydrophobic sample matrix in limited quantity.
Collapse
|
16
|
McDaniel C, Mallampati SR, Wise A. Metals in Cannabis Vaporizer Aerosols: Sources, Possible Mechanisms, and Exposure Profiles. Chem Res Toxicol 2021; 34:2331-2342. [PMID: 34705462 DOI: 10.1021/acs.chemrestox.1c00230] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In recent years, cannabis vaporizer cartridges have increased in popularity and availability, and there are concerns regarding exposure to heavy-metal compounds from their use. The physical components of the cartridge devices themselves have been implicated as a potential source of metal exposure, but it is not known if these metals migrate into the inhalable vapor. This study analyzes the components of vaporizer cartridges for 10 different metals and also collects aerosol mixtures from 13 randomly purchased commercially available cannabis cartridges from Washington State to compare their elemental profiles. Results indicate that chromium, copper, nickel, as well as smaller amounts of lead, manganese, and tin migrate into the cannabis oil and inhaled vapor phase, resulting in a possible acute intake of an amount of inhaled metals above the regulatory standard of multiple governmental bodies. Noncartridge heating methods of cannabis flower and concentrate were compared, and results indicate that the heating device itself is a source of metal contamination. As safety and compliance testing regulations evolve, it will be important to include more than the standard As, Cd, Hg, and Pb to the list of regulated metals.
Collapse
Affiliation(s)
- Charles McDaniel
- Medicine Creek Analytics, 3700 Pacific Highway East, Fife, Washington 98424, United States
| | | | - Amber Wise
- Medicine Creek Analytics, 3700 Pacific Highway East, Fife, Washington 98424, United States
| |
Collapse
|
17
|
Mara A, Langasco I, Deidda S, Caredda M, Meloni P, Deroma M, Pilo MI, Spano N, Sanna G. ICP-MS Determination of 23 Elements of Potential Health Concern in Liquids of e-Cigarettes. Method Development, Validation, and Application to 37 Real Samples. Molecules 2021; 26:6680. [PMID: 34771088 PMCID: PMC8588553 DOI: 10.3390/molecules26216680] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 10/29/2021] [Accepted: 10/29/2021] [Indexed: 11/29/2022] Open
Abstract
The lack of interest in the determination of toxic elements in liquids for electronic cigarettes (e-liquids) has so far been reflected in the scarce number of accurate and validated analytical methods devoted to this aim. Since the strong matrix effects observed for e-liquids constitute an exciting analytical challenge, the main goal of this study was to develop and validate an ICP-MS method aimed to quantify 23 elements in 37 e-liquids of different flavors. Great attention has been paid to the critical phases of sample pre-treatment, as well as to the optimization of the ICP-MS conditions for each element and of the quantification. All samples exhibited a very low amount of the elements under investigation. Indeed, the sum of their average concentration was of ca. 0.6 mg kg-1. Toxic elements were always below a few tens of a μg per kg-1 and, very often, their amount was below the relevant quantification limits. Tobacco and tonic flavors showed the highest and the lowest concentration of elements, respectively. The most abundant elements came frequently from propylene glycol and vegetal glycerin, as confirmed by PCA. A proper choice of these substances could further decrease the elemental concentration in e-liquids, which are probably barely involved as potential sources of toxic elements inhaled by vapers.
Collapse
Affiliation(s)
- Andrea Mara
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Ilaria Langasco
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Sara Deidda
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Marco Caredda
- AGRIS Sardegna, Loc. Bonassai, S.S. 291 Km 18.6, 07100 Sassari, Italy;
| | - Paola Meloni
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Mario Deroma
- Dipartimento di Agraria, Università degli Studi di Sassari, Viale Italia 39/a, 07100 Sassari, Italy;
| | - Maria I. Pilo
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Nadia Spano
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| | - Gavino Sanna
- Dipartimento di Chimica e Farmacia, Università degli Studi di Sassari, Via Vienna 2, 07100 Sassari, Italy; (A.M.); (I.L.); (S.D.); (P.M.); (M.I.P.); (N.S.)
| |
Collapse
|
18
|
Olmedo P, Rodrigo L, Grau-Pérez M, Hilpert M, Navas-Acién A, Téllez-Plaza M, Pla A, Gil F. Metal exposure and biomarker levels among e-cigarette users in Spain. ENVIRONMENTAL RESEARCH 2021; 202:111667. [PMID: 34256077 DOI: 10.1016/j.envres.2021.111667] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/29/2021] [Accepted: 07/05/2021] [Indexed: 05/11/2023]
Abstract
The use of electronic cigarettes (e-cigarettes) has increased due to the belief that they are healthier than tobacco cigarettes. E-cigarettes contain a metallic heating coil (composed of Ni, Cr, Al and other metals) to heat a solution (commonly called e-liquid) and convert it into an aerosol. This aerosol is inhaled (vaped) by the users who can be potentially exposed to a wide variety of metals. We investigated the possible transfer of metals from the coil to the e-liquid and the generated aerosol, and how the exposure to this aerosol can increase metal body burden in e-cigarette users. We recruited 75 e-cigarette users (50 who only vaped and 25 dual users who vaped and smoked) and 25 controls who neither vaped nor smoked. E-liquid samples before (dispenser e-liquid) and after (tank e-liquid) being added to their devices were collected. Aerosol samples were collected using a condensation method. All participants provided urine and hair samples. All samples were analyzed for metals by ICP-MS. We observed higher metal concentrations in the aerosol and tank e-liquid (in contact with the coil) compared to the dispenser e-liquid (before contact with the coil). The median concentrations for some of the metals with the most remarkable increases in aerosol and tank e-liquid vs. dispenser e-liquid were 36.90 and 62.73 vs. 18.29 μg/kg for Al; 6.71 and 28.97 vs. 0.98 μg/kg for Cr; 91.39 and 414.47 vs. 1.64 μg/kg for Ni; 738.99 and 744.24 vs. 16.56 μg/kg for Zn; and 10.17 and 22.31 vs. 0.88 μg/kg for Pb. We also found detectable and potentially high concentrations of other metals such as Mn, Cu, Sb and Sn. In urine, increases in the median levels (μg/g creatinine) in vapers/duals vs. controls were observed for some metals, including Cr (0.34/0.28 vs. 0.20), Cu (1.72/2.36 vs. 1.46), Sn (0.26/0.31 vs. 0.18) and Pb (0.39/0.44 vs. 0.22). In hair, there were no differences in metal concentrations among the three groups. In conclusion, e-cigarettes are likely a source of metals such as Cr, Cu, Ni, Pb or Sn. These metals come from the device, likely the heating resistance, as their concentrations were low in the dispenser e-liquid and higher in the aerosol and the e-liquid left in the tank. Although the exposure to e-cigarette aerosol can have an influence in the body burden of metals, aerosol metal levels were not clearly associated with metal levels in biological samples such as urine or hair in e-cigarette users in this study.
Collapse
Affiliation(s)
- Pablo Olmedo
- Department of Legal Medicine and Toxicology. School of Medicine, University of Granada, Granada, Spain
| | - Lourdes Rodrigo
- Department of Legal Medicine and Toxicology. School of Medicine, University of Granada, Granada, Spain
| | - María Grau-Pérez
- Area of Cardiometabolic and Renal Risk, Biomedical Research Institute Hospital Clinic de Valencia (INCLIVA), Valencia, Spain
| | - Markus Hilpert
- Department of Environmental Health Sciences, Columbia University Mailman School of Public Health, New York, NY, USA
| | - Ana Navas-Acién
- Department of Environmental Health Sciences, Columbia University Mailman School of Public Health, New York, NY, USA
| | - María Téllez-Plaza
- Department of Chronic Disease Epidemiology. Carlos III Health Institute, Madrid, Spain
| | - Antonio Pla
- Department of Legal Medicine and Toxicology. School of Medicine, University of Granada, Granada, Spain
| | - Fernando Gil
- Department of Legal Medicine and Toxicology. School of Medicine, University of Granada, Granada, Spain.
| |
Collapse
|
19
|
Margham J, McAdam K, Cunningham A, Porter A, Fiebelkorn S, Mariner D, Digard H, Proctor C. The Chemical Complexity of e-Cigarette Aerosols Compared With the Smoke From a Tobacco Burning Cigarette. Front Chem 2021; 9:743060. [PMID: 34660535 PMCID: PMC8514950 DOI: 10.3389/fchem.2021.743060] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Accepted: 09/10/2021] [Indexed: 11/13/2022] Open
Abstract
Background: As e-cigarette popularity has increased, there is growing evidence to suggest that while they are highly likely to be considerably less harmful than cigarettes, their use is not free of risk to the user. There is therefore an ongoing need to characterise the chemical composition of e-cigarette aerosols, as a starting point in characterising risks associated with their use. This study examined the chemical complexity of aerosols generated by an e-cigarette containing one unflavored and three flavored e-liquids. A combination of targeted and untargeted chemical analysis approaches was used to examine the number of compounds comprising the aerosol. Contributions of e-liquid flavors to aerosol complexity were investigated, and the sources of other aerosol constituents sought. Emissions of 98 aerosol toxicants were quantified and compared to those in smoke from a reference tobacco cigarette generated under two different smoking regimes. Results: Combined untargeted and targeted aerosol analyses identified between 94 and 139 compounds in the flavored aerosols, compared with an estimated 72-79 in the unflavored aerosol. This is significantly less complex (by 1-2 orders of magnitude) than the reported composition of cigarette smoke. Combining both types of analysis identified 5-12 compounds over and above those found by untargeted analysis alone. Gravimetrically, 89-99% of the e-cigarette aerosol composition was composed of glycerol, propylene glycol, water and nicotine, and around 3% comprised other, more minor, constituents. Comparable data for the Ky3R4F reference tobacco cigarette pointed to 58-76% of cigarette smoke "tar" being composed of minor constituents. Levels of the targeted toxicants in the e-cigarette aerosols were significantly lower than those in cigarette smoke, with 68.5->99% reductions under ISO 3308 puffing conditions and 88.4->99% reductions under ISO 20778 (intense) conditions; reductions against the WHO TobReg 9 priority list were around 99%. Conclusion: These analyses showed that the e-cigarette aerosols contain fewer compounds and at significantly lower concentrations than cigarette smoke. The chemical diversity of an e-cigarette aerosol is strongly impacted by the choice of e-liquid ingredients.
Collapse
Affiliation(s)
- J. Margham
- Group Research and Development, British American Tobacco, Southampton, United Kingdom
| | - K. McAdam
- McAdam Scientific Ltd., Eastleigh, United Kingdom
| | - A. Cunningham
- Group Research and Development, British American Tobacco, Southampton, United Kingdom
| | - A. Porter
- Independent Researcher, Montreal, QC, Canada
| | - S. Fiebelkorn
- Group Research and Development, British American Tobacco, Southampton, United Kingdom
| | - D. Mariner
- Mariner Science Ltd., Salisbury, United Kingdom
| | - H. Digard
- Group Research and Development, British American Tobacco, Southampton, United Kingdom
| | - C. Proctor
- DoctorProctorScience Ltd., Ascot, United Kingdom
| |
Collapse
|
20
|
AL-Qaysi WW, Abdulla FH. Analytical methods for the identification of micro/nano metals in e-cigarette emission samples: a review. CHEMICKE ZVESTI 2021; 75:6169-6180. [PMID: 34421189 PMCID: PMC8370834 DOI: 10.1007/s11696-021-01779-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 07/04/2021] [Indexed: 12/04/2022]
Abstract
In this review, numerous analytical methods to quantify the heavy and trace elements emitted from electronic cigarettes, cigarettes liquid and atomizer. The selection of a method was dependent upon the purpose, e.g., quantification or identification of elements only. The introductory part of this review focuses on describing the importance of setting up an electronic cigarettes- associated safety profile. The review dealt with studies that assessed elements in sizes ranging from nano to micro. The formation of different degradation chemical substances as well as impurity trends can be indicated through chemical investigation of metals in electronic cigarettes. Some studies have been covered that show the uses and benefits of. It is noticeable from all the collected sources that the minerals emitted from the smoke of e- cigs do not constitute any significant damage, as the percentage is very small, with the exception of minerals that may be emitted from the components of the device after heating it if the components of the e- cig are of poor specifications, except in the case of long-term accumulation. For this reason, an electronic cigarette can help smokers to quit smoking tobacco and replace it with electronic cigarettes smoke with distinctive flavors.
Collapse
Affiliation(s)
- Wafaa Waleed AL-Qaysi
- Institute of Analytical Chemistry, Chemo and Biosensors, University of Regensburg, Universitätsstraße 31, 93040 Regensburg, Germany
- Department of Chemistry, College of Science, University of Baghdad, Al-Jadriya campus, 10071 Baghdad, Iraq
| | - Fatma H. Abdulla
- Department of Chemistry, College of Science, University of Baghdad, Al-Jadriya campus, 10071 Baghdad, Iraq
| |
Collapse
|
21
|
Sepand MR, Maghsoudi AS, Shadboorestan A, Mirnia K, Aghsami M, Raoufi M. Cigarette smoke-induced toxicity consequences of intracellular iron dysregulation and ferroptosis. Life Sci 2021; 281:119799. [PMID: 34229007 DOI: 10.1016/j.lfs.2021.119799] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 06/27/2021] [Accepted: 06/30/2021] [Indexed: 01/18/2023]
Abstract
Despite numerous studies on the mechanisms of cigarette smoking toxicity over the past three decades, some aspects remain obscure. Recent developments have drawn attention to some hopeful indicators that allow us to advance our awareness of cigarette-induced cell death. Ferroptosis is considered a type of governed death of cells distinguished by the iron-dependent lipid hydroperoxide deposition to fatal concentrations. Ferroptosis has been linked with pathological settings such as neurodegenerative diseases, cancer, heart attack, hemorrhagic stroke, traumatic brain injury, ischemia-reperfusion injury, and renal dysfunction. This review tries to explain the causal role of ferroptosis cascade in cigarette smoke-mediated toxicity and cell death, highlighting associations on potential action mechanisms and proposing suggestions for its detoxifying and therapeutic interventions.
Collapse
Affiliation(s)
- Mohammad Reza Sepand
- Nanotechnology Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 13169-43551, Iran
| | - Armin Salek Maghsoudi
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran, Iran
| | - Amir Shadboorestan
- Department of Toxicology, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
| | - Kayvan Mirnia
- Department of Neonatology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mehdi Aghsami
- Department of Pharmacology and Toxicology, School of Pharmacy, Iran University of Medical Sciences, Tehran, Iran
| | - Mohammad Raoufi
- Nanotechnology Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran 13169-43551, Iran; Physical Chemistry I and Research Center of Micro and Nanochemistry (Cμ), University of Siegen, Siegen, Germany.
| |
Collapse
|
22
|
Nicholson T, Scott A, Newton Ede M, Jones SW. The impact of E-cigarette vaping and vapour constituents on bone health. J Inflamm (Lond) 2021; 18:16. [PMID: 33952248 PMCID: PMC8097983 DOI: 10.1186/s12950-021-00283-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Accepted: 04/25/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND In contrast to cigarettes, electronic cigarette use (E-cigarettes) has grown substantially over the last decade. This is due to their promotion as both a safer alternative to cigarettes and as an aide to stop smoking. Critically, upon E-cigarette use, the user may be exposed to high doses of nicotine in addition to other compounds including flavouring chemicals, metal particulates and carbonyl compounds, particularly in highly vascularised tissues such as bone. However, there has been limited investigation into the impact of E-cigarette usage on bone physiology, particularly over extended time periods and there are no clinical recommendations regarding E-cigarette usage in relation to orthopaedic surgery. This literature review draws together data from studies that have investigated the impact of E-cigarette vapour and its major constituents on bone, detailing the models utilised and the relevant mechanistic and functional results. MAIN BODY Currently there is a lack of studies both in vivo and in vitro that have utilised E-cigarette vapour, necessary to account for changes in chemical composition of E-cigarette liquids upon vaping. There is however evidence that human bone and bone cells express nicotine receptors and exposure of both osteoblasts and osteoclasts to nicotine, in high concentrations may reduce their viability and impair function. Similarly, it appears that aldehydes and flavouring chemicals may also negatively impact osteoblast viability and their ability to form bone. However, such functional findings are predominantly the result of studies utilising bone cell lines such as MG-63 or Saos-2 cells, with limited use of human osteoblasts or osteoclasts. Additionally, there is limited consideration for a possible impact on mesenchymal stem cells, which can also play an import role in bone repair. CONCLUSION Understanding the function and mechanism of action of the various components of E-cigarette vapour in mediating human bone cell function, in addition to long term studies to determine the potential harm of chronic E-cigarette use on human bone will be important to inform users of potential risks, particularly regarding bone healing following orthopaedic surgery and injury.
Collapse
Affiliation(s)
- Thomas Nicholson
- grid.6572.60000 0004 1936 7486Institute of Inflammation and Ageing, MRC-ARUK Centre for Musculoskeletal Ageing Research, University of Birmingham, Birmingham, B15 2TT UK
| | - Aaron Scott
- grid.6572.60000 0004 1936 7486Institute of Inflammation and Ageing, MRC-ARUK Centre for Musculoskeletal Ageing Research, University of Birmingham, Birmingham, B15 2TT UK
| | - Matthew Newton Ede
- grid.416189.30000 0004 0425 5852The Royal Orthopaedic Hospital, Birmingham, B31 2AP UK
| | - Simon W. Jones
- grid.6572.60000 0004 1936 7486Institute of Inflammation and Ageing, MRC-ARUK Centre for Musculoskeletal Ageing Research, University of Birmingham, Birmingham, B15 2TT UK
| |
Collapse
|
23
|
Nicholson T, Scott A, Newton Ede M, Jones SW. Do E-cigarettes and vaping have a lower risk of osteoporosis, nonunion, and infection than tobacco smoking? Bone Joint Res 2021; 10:188-191. [PMID: 33709767 PMCID: PMC7998067 DOI: 10.1302/2046-3758.103.bjr-2020-0327.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Affiliation(s)
- Thomas Nicholson
- MRC-ARUK Centre for Musculoskeletal Ageing Research, Medical School, Queen Elizabeth Hospital, University of Birmingham, Birmingham, UK
| | - Aaron Scott
- Birmingham Acute Care Research Group Institute of Inflammation and Ageing (IIA), University of Birmingham, Birmingham, UK
| | | | - Simon W. Jones
- MRC-ARUK Centre for Musculoskeletal Ageing Research, Medical School, Queen Elizabeth Hospital, University of Birmingham, Birmingham, UK,Simon W. Jones. E-mail:
| |
Collapse
|
24
|
Omaiye EE, Williams M, Bozhilov KN, Talbot P. Design features and elemental/metal analysis of the atomizers in pod-style electronic cigarettes. PLoS One 2021; 16:e0248127. [PMID: 33690644 PMCID: PMC7943009 DOI: 10.1371/journal.pone.0248127] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/21/2021] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND The atomizers of electronic cigarettes (ECs) contain metals that transfer to the aerosol upon heating and may present health hazards. This study analyzed 4th-generation EC pod atomizer design features and characterized their elemental/metal composition. METHODS Eleven EC pods from six brands/manufacturers were purchased at local shops and online. Pods were dissected and imaged using a Canon EOS Rebel SL2 camera. Elemental analysis and mapping of atomizer components was done using a scanning electron microscope coupled with an energy dispersive x-ray spectrometer. RESULTS EC pods varied in size and design. The internal atomizer components were similar across brands except for variations occurring mainly in the wicks and filaments of some products. The filaments were either Elinvar (nickel, iron, and chromium) (36.4%), nichrome (36.4%), iron-chromium (18.2%), or nickel (9%). Thick wires present in 55% of the atomizers were mainly nickel and were joined to filaments by brazing. Wire-connector joints were Elinvar. Metal air tubes were made of Elinvar (50%), nickel, zinc, copper, and tin (37.5%), and nickel and copper (12.5%). Most of the wick components were silica, except for two pods (PHIX and Mico), which were mainly ceramic. Connectors contained gold-plated nickel, iron-chromium multiple alloys of nickel, zinc, gold, iron, and copper. Wick chambers were made of Elinvar. Outer casings were either nickel, copper-tin, or nickel-copper alloys. Magnets were nickel with minor iron, copper, and sulfur. Some frequently occurring elements were high in relative abundance in atomizer components. CONCLUSIONS The atomizers of pods are similar to previous generations, with the introduction of ceramic wicks and magnets in the newer generations. The elements in EC atomizers may transfer into aerosols and adversely affect health and accumulate in the environment.
Collapse
Affiliation(s)
- Esther E. Omaiye
- Environmental Toxicology Graduate Program, University of California Riverside, Riverside, CA, United States of America
- Department of Molecular, Cell and Systems Biology, University of California Riverside, Riverside, CA, United States of America
| | - Monique Williams
- Department of Molecular, Cell and Systems Biology, University of California Riverside, Riverside, CA, United States of America
| | - Krassimir N. Bozhilov
- Central Facility for Advanced Microscopy and Microanalysis, University of California Riverside, Riverside, CA, United States of America
| | - Prue Talbot
- Department of Molecular, Cell and Systems Biology, University of California Riverside, Riverside, CA, United States of America
| |
Collapse
|
25
|
Singh DP, Begum R, Kaur G, Bagam P, Kambiranda D, Singh R, Batra S. E-cig vapor condensate alters proteome and lipid profiles of membrane rafts: impact on inflammatory responses in A549 cells. Cell Biol Toxicol 2021; 37:773-793. [PMID: 33469865 DOI: 10.1007/s10565-020-09573-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 11/12/2020] [Indexed: 01/14/2023]
Abstract
Electronic cigarettes (e-cigs) are battery-operated heating devices that aerosolize e-liquid, typically containing nicotine and several other chemicals, which is then inhaled by a user. Over the past decade, e-cigs have gained immense popularity among both smokers and non-smokers. One reason for this is that they are advertised as a safe alternative to conventional cigarettes. However, the recent reports of e-cig use associated lung injury have ignited a considerable debate about the relative harm and benefits of e-cigs. The number of reports about e-cig-induced inflammation and pulmonary health is increasing as researchers seek to better understand the effects of vaping on human health. In line with this, we investigated the molecular events responsible for the e-cig vapor condensate (ECVC)-mediated inflammation in human lung adenocarcinoma type II epithelial cells (A549). In an attempt to limit the variables caused by longer ingredient lists of flavored e-cigs, tobacco-flavored ECVC (TF-ECVC±nicotine) was employed for this study. Interestingly, we observed significant upregulation of cytokines and chemokines (IL-6, IL-8, and MCP-1) in A549 cells following a 48 h TF-ECVC challenge. Furthermore, there was a significant increase in the expression of pattern recognition receptors TLR-4 and NOD-1, lipid raft-associated protein caveolin-1, and transcription factor NF-кB in TF-ECVC with and/or without nicotine-challenged lung epithelial cells. Our results further demonstrate the harboring of TLR-4 and NOD-1 in the caveolae of TF-ECVC-challenged A549 cells. Proteomic and lipidomic analyses of lipid raft fractions from control and challenged cells revealed a distinct protein and lipid profile in TF-ECVC (w/wo nicotine)-exposed A549 cells. Interestingly, the inflammatory effects of TF-ECVC (w/wo nicotine) were inhibited following the caveolin-1 knockdown, thus demonstrating a critical role of caveolae raft-mediated signaling in eliciting inflammatory responses upon TF-ECVC challenge. Graphical Abstract Graphical Abstract.
Collapse
Affiliation(s)
- Dhirendra Pratap Singh
- Laboratory of Pulmonary Immunotoxicology, Department of Environmental Toxicology, 129 Health Research Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA
| | - Rizwana Begum
- Laboratory of Pulmonary Immunotoxicology, Department of Environmental Toxicology, 129 Health Research Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA
| | - Gagandeep Kaur
- Laboratory of Pulmonary Immunotoxicology, Department of Environmental Toxicology, 129 Health Research Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA
| | - Prathyusha Bagam
- Laboratory of Pulmonary Immunotoxicology, Department of Environmental Toxicology, 129 Health Research Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA
| | - Devaiah Kambiranda
- Southern University Agriculture Research and Extension Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA
| | - Rakesh Singh
- Translational Science Laboratory, FSU College of Medicine, Tallahassee, FL, 32309, USA
| | - Sanjay Batra
- Laboratory of Pulmonary Immunotoxicology, Department of Environmental Toxicology, 129 Health Research Center, Southern University and A&M College, Baton Rouge, LA, 70813, USA.
| |
Collapse
|
26
|
Fischman JS, Sista S, Lee D, Cuadra GA, Palazzolo DL. Flavorless vs. Flavored Electronic Cigarette-Generated Aerosol and E-Liquid on the Growth of Common Oral Commensal Streptococci. Front Physiol 2020; 11:585416. [PMID: 33329035 PMCID: PMC7732452 DOI: 10.3389/fphys.2020.585416] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Accepted: 10/28/2020] [Indexed: 11/16/2022] Open
Abstract
Introduction Electronic cigarette (ECIG) use or vaping has become popular globally. While the question “Is vaping safer than smoking?” continues, it is becoming clearer that one of the most dangerous components of E-liquids are the flavorings. Since the oral cavity is the first anatomical site to be assaulted by ECIG aerosol, the aim of this study is to test the hypothesis that flavored ECIG aerosols or E-liquids pose a more detrimental effect on the growth of commensal oral streptococcal bacteria compared to flavorless aerosols or E-liquids. Methods Kirby Bauer assays and 24-h planktonic growth curves were used to compare the effects of flavorless vs. flavored (tobacco, menthol, cinnamon, strawberry and blueberry) ECIG-generated aerosols and E-liquids on the growth of four common strains of oral commensal bacteria (Streptococcus gordonii, Streptococcus intermedius, Streptococcus mitis and Streptococcus oralis). Results Kirby Bauer assays revealed inhibition of growth for all bacteria tested when exposed to 100% menthol, cinnamon or strawberry flavors. In contrast, 5% flavor in E-liquid had no effect. When exposed to 100 puffs of ECIG-generated aerosol ± flavors (≈ 0.05% flavor in brain heart infusion media) or an equivalent amount of E-liquid ± flavors, twenty-four hour planktonic growth curves indicated no effect on growth for all streptococci tested. Subsequent twenty-four hour planktonic growth curves testing the effects of E-liquid ± flavors (0.0625, 0.125, 0.25, 0.3125, 0.625, and 1.25% flavor in brain heart infusion media) revealed dose-dependent inhibition of growth, particularly for menthol, cinnamon and strawberry), for all bacteria tested. Conclusion These results support the hypothesis that flavored E-liquids are more detrimental to the growth of oral commensal bacteria than unflavored E-liquids. The streptococci tested in this study are early colonizers and part of the foundation of oral biofilms and dental plaque. Disturbances in the composition and growth of these primary colonizers is crucial to the development of a healthy dental plaque and host-bacteria interactions. E-liquids and their aerosols containing flavoring agents alter the growth of these bacteria. Such perturbations of pioneering oral communities pose a potential risk to the health of the oral cavity and, ultimately, health in general.
Collapse
Affiliation(s)
- Jacob S Fischman
- Department of Biology, Muhlenberg College, Allentown, PA, United States
| | - Swapna Sista
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN, United States
| | - DongKeun Lee
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN, United States
| | | | - Dominic L Palazzolo
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN, United States
| |
Collapse
|
27
|
Pearce K, Gray N, Gaur P, Jeon J, Suarez A, Shannahan J, Pappas RS, Watson-Wright C. Toxicological analysis of aerosols derived from three electronic nicotine delivery systems using normal human bronchial epithelial cells. Toxicol In Vitro 2020; 69:104997. [PMID: 32896591 DOI: 10.1016/j.tiv.2020.104997] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Revised: 07/21/2020] [Accepted: 09/03/2020] [Indexed: 12/19/2022]
Abstract
Electronic nicotine delivery systems (ENDS) are a rapidly growing global market advertised as a safer alternative to combustible cigarettes. However, comprehensive investigations of END aerosol physicochemical and toxicological properties have not been fully explored across brands to assess relative safety. In this study, we evaluated aerosols collected from three ENDS - Juul Fruit Medley (5% nicotine), Logic Power (2.4% nicotine), and Mistic (1.8% nicotine). ENDS aerosols were generated using standard machine puffing regimen and collected with a novel fluoropolymer condensation trap. Triple quadrupole-inductively coupled plasma-mass determined the presence of heavy metals in collected aerosols. The toxicological effects of ENDS aerosols on normal human bronchial epithelial cells (NHBE) were investigated using cellular viability, reactive oxygen species, oxidative stress assays, along with DNA damage assessments using the CometChip©. Results indicated the total metal concentrations within collected ENDS aerosols were higher for Mistic and Logic compared to Juul. Logic Power aerosols elicited higher reactive oxygen species levels than Mistic and Juul in NHBE after 24-h exposure. Similar dose-dependent reductions of cellular viability and total glutathione were found for each exposure. However, Logic and Juul aerosols caused greater single stranded DNA damage compared to Mistic. Our study indicates that regardless of brand, ENDS aerosols are toxic to upper airway epithelial cells and may pose a potential respiratory hazard to occasional and frequent users.
Collapse
Affiliation(s)
- K Pearce
- School of Public Health, Georgia State University, Atlanta, GA 30030, United States of America
| | - N Gray
- Tobacco Inorganics Group, Centers for Disease Control and Prevention, Atlanta, GA 30341, United States of America
| | - P Gaur
- School of Public Health, Georgia State University, Atlanta, GA 30030, United States of America
| | - J Jeon
- School of Public Health, Georgia State University, Atlanta, GA 30030, United States of America
| | - A Suarez
- School of Public Health, Georgia State University, Atlanta, GA 30030, United States of America
| | - J Shannahan
- School of Health Sciences, Purdue University, West Lafayette, IN 47907, United States of America
| | - R S Pappas
- Tobacco Inorganics Group, Centers for Disease Control and Prevention, Atlanta, GA 30341, United States of America
| | - C Watson-Wright
- School of Public Health, Georgia State University, Atlanta, GA 30030, United States of America.
| |
Collapse
|
28
|
Neu HM, Lee A, Brandis JEP, Patel V, Schneider A, Kane MA, Dalby RN, Michel SLJ. Cigalike electronic nicotine delivery systems e-liquids contain variable levels of metals. Sci Rep 2020; 10:11907. [PMID: 32681061 PMCID: PMC7368082 DOI: 10.1038/s41598-020-67789-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Accepted: 06/10/2020] [Indexed: 11/17/2022] Open
Abstract
Electronic nicotine delivery systems (ENDS) are prefilled, battery-operated products intended to deliver nicotine to the user via an inhaled complex aerosol formed by heating a liquid composed of propylene glycol and glycerol, also referred to as vegetable glycerin and collectively called e-liquid, that contains nicotine and various flavor ingredients. Since their introduction in 2006, the number of ENDS on the market has increased exponentially. Despite their growing ubiquity, the possible health risks associated with ENDS use remain poorly understood. One potential concern is the presence of toxic metals in the e-liquid and aerosol. Herein, we report the evaluation of the metal content in the e-liquids from a series of commercially available cigalike ENDS brands (various flavors) determined using inductively coupled plasma mass spectrometry (ICP-MS) following e-liquid extraction. Each brand of cigalike ENDS was purchased at least three times at retail outlets in the Baltimore, Maryland metropolitan region over a period of six months (September 2017 to February 2018). This allowed for comparison of batch-to-batch variability. Several potentially toxic metals, including lead, chromium, copper, and nickel were detected in the e-liquids. In addition, high variability in metal concentrations within and between brands and flavors was observed . The internal assembled parts of each cartridge were analyzed by X-ray imaging, before dissembling so that the materials used to manufacture each cartridge could be evaluated to determine the metals they contained. Following washing to remove traces of e-liquid, lead, chromium, copper and nickel were all detected in the cigalike ENDS prefilled cartridges, suggesting one potential source for the metals found in the e-liquids. Collectively, these findings can inform further evaluation of product design and manufacturing processes, including quantification of metal concentrations in e-liquids over foreseeable storage times, safeguards against high concentrations of metals in the e-liquid before and after aerosolization (by contact with a metal heating coil), and control over batch-to-batch variability.
Collapse
Affiliation(s)
- Heather M Neu
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA
| | - Angela Lee
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA
| | - Joel E P Brandis
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA
| | - Vyomesh Patel
- Center for Tobacco Products, US Food and Drug Administration, Silver Spring, MD, USA
| | - Abraham Schneider
- Department of Oncology and Diagnostic Sciences, University of Maryland School of Dentistry, Baltimore, MD, USA
| | - Maureen A Kane
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA
| | - Richard N Dalby
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA
| | - Sarah L J Michel
- Department of Pharmaceutical Sciences, University of Maryland School of Pharmacy, Baltimore, MD, USA.
| |
Collapse
|
29
|
Reilly SM, Cheng T, DuMond J. Method Validation Approaches for Analysis of Constituents in ENDS. TOB REGUL SCI 2020; 6:242-265. [PMID: 32789155 PMCID: PMC7416875 DOI: 10.18001/trs.6.4.3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE We assessed how many peer-reviewed publications reporting chemical quantities and/or yields from electronic nicotine delivery systems (ENDS) have included adequate method validation characteristics in the publication for appropriate interpretation of data quality for informing tobacco regulatory science. METHODS We searched 5 databases (Web of Knowledge, PubMed, SciFinder, Embase, EBSCOhost) for ENDS publications between January 2007 and September 2018. Of the 283 publications screened, 173 publications were relevant for analysis. We identified the publications that report a certain degree of control in data quality, ie, the publications that report marginally validated methods (MVMs). MVMs refer to the methods that: (1) report 3 or more International Conference on Harmonisation (ICH) method validation characteristics, (2) state the method was validated, (3) cite their own previous publication(s) that report MVMs, or (4) use a method within the accreditation scope of an accredited laboratory. RESULTS Overall, 97 publications (56%) report MVMs in their studies. This percentage also reflects the publication distribution for the majority of the 28 chemicals measured by MVMs. CONCLUSIONS This study highlights the need for reporting sufficient validation characteristics following appropriate guidance to ensure the accuracy and reliability of the published analytical data for proper data interpretations that may support policy.
Collapse
Affiliation(s)
- Samantha M Reilly
- Office of Science, Center for Tobacco Products, Food and Drug Administration, Silver Spring, MD
| | - Tianrong Cheng
- Office of Science, Center for Tobacco Products, Food and Drug Administration, Silver Spring, MD
| | - Jenna DuMond
- Office of Science, Center for Tobacco Products, Food and Drug Administration, Silver Spring, MD
| |
Collapse
|
30
|
Mahilang M, Deb MK, Nirmalkar J, Pervez S. Influence of fireworks emission on aerosol aging process at lower troposphere and associated health risks in an urban region of eastern central India. ATMOSPHERIC POLLUTION RESEARCH 2020; 11:1127-1141. [PMID: 32322156 PMCID: PMC7172683 DOI: 10.1016/j.apr.2020.04.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 04/17/2020] [Accepted: 04/17/2020] [Indexed: 05/05/2023]
Abstract
To study the influence of fireworks in atmospheric aerosols and their effect on health during the extreme firework days, fireworks tracer metals and carbonaceous species in size-distributed aerosols in the lower troposphere at Raipur in eastern central India were investigated during the 2018 Deepawali festival. Aerosol samples were collected, before Deepawali period (BDP, n = 5), during Deepawali period (DDP, n = 5) and after Deepawali period (ADP, n = 5). Bimodal size-distribution with intense fine mode peak was found for Na during DDP. Bimodal distribution with fine mode intense peak was found for K during DDP. The bimodal size distribution of K was found common for other events because of biomass burning emissions, whereas high intense peak during DDP indicated mixed sources from biomass burning and fireworks. During DDP, K and Ca were well correlated (r2 = 0.93) together. Strong metal-metal correlations were found between the following pairs, Zn-Fe, Cu-Fe and Cu-Ca, which indicated the similar firecrackers burning source. The atmospheric aging of aerosols was also found significantly high during fireworks days. Aging of aerosols were higher because of heterogeneous reactions of SO2 and NOx on aerosols directly emitted from fireworks. The observed high values of inhalation dose of elemental carbon during DDP period imposed higher risk of respiratory diseases. This study has provided carbonaceous fractions composition data as a tool to detect the aging processes of fireworks in ultra-fine, fine and coarse mode particles during the extreme firework days. Inhalation doses were calculated to establish potential influence on human health.
Collapse
Affiliation(s)
- Mithlesh Mahilang
- School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur, 492010, Chhattisgarh, India
| | - Manas Kanti Deb
- School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur, 492010, Chhattisgarh, India
- Corresponding author.
| | - Jayant Nirmalkar
- School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur, 492010, Chhattisgarh, India
- Korea Research Institute of Standards and Science, Daejeon, 34113, South Korea
| | - Shamsh Pervez
- School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur, 492010, Chhattisgarh, India
| |
Collapse
|
31
|
Electronic nicotine delivery system design and aerosol toxicants: A systematic review. PLoS One 2020; 15:e0234189. [PMID: 32497139 PMCID: PMC7272070 DOI: 10.1371/journal.pone.0234189] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 05/20/2020] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Electronic nicotine delivery systems (ENDS; e-cigarettes), consisting of a battery, heating element and e-liquid, have evolved significantly with wide variation in design, components, operating powers, and chemical constituents. Generated aerosols have been reported to contain potentially toxic substances. We conducted a systematic review to assess what is known about the presence of toxicants in ENDS aerosols in order to inform how system design could mitigate risk. METHODS Articles reporting on or evaluating design characteristics of ENDS and aerosol constituents were included and summarized. RESULTS The search identified 2,305 articles, of which 92 were included after full-text review. Findings were grouped into 6 major categories of potentially harmful chemicals: carbonyls, volatile organic chemicals, trace elements, reactive oxygen species and free radicals, polycyclic aromatic hydrocarbons, and tobacco-specific nitrosamines. In general, higher concentrations of aerosol toxicants are associated with increased power or voltage. Aerosol toxicants are also associated with e-liquid flavoring agents existing as primary ingredients or as products of thermal degradation. CONCLUSIONS Improved ENDS design can reduce toxicant levels. Additional research is needed to develop a framework for optimizing system characteristics to minimize exposure, especially with respect to heating power and e-liquids. Both manufacturers and regulatory agencies have roles in reducing toxicants and potential health risks from ENDS.
Collapse
|
32
|
Prokopowicz A, Sobczak A, Szuła-Chraplewska M, Ochota P, Kośmider L. Exposure to Cadmium and Lead in Cigarette Smokers Who Switched to Electronic Cigarettes. Nicotine Tob Res 2020; 21:1198-1205. [PMID: 30107446 DOI: 10.1093/ntr/nty161] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Accepted: 08/08/2018] [Indexed: 12/23/2022]
Abstract
INTRODUCTION Electronic cigarettes (ECs) seem to be a less harmful alternative for conventional cigarettes. This study aimed to assess whether the generated aerosols from ECs contain lower amount of cadmium (Cd) and lead (Pb) than cigarette smoke and to detect any changes in exposure to Cd and Pb among cigarette smokers who switched completely or partially to EC. METHODS EC aerosols and cigarette smoke were generated, and the determination of Cd and Pb in trapped samples and e-liquids was performed by the electrothermal atomic absorption spectrometry method. A cross-sectional, group-based survey was carried out using 156 volunteers classified into groups of nonsmokers, EC-only users, dual EC users-cigarette smokers, and cigarette-only smokers. Using electrothermal atomic absorption spectrometry, blood Cd and Pb levels were measured, and the results were compared by analysis of covariance. RESULTS Transfer of Cd and Pb to EC aerosol was found to be minimal, although the metals were present in the remaining e-liquid from tanks used for vapor generation. The geometric mean blood Cd concentration adjusted for age and sex was 0.44 (95% confidence interval = 0.37 to 0.52) µg/L in the EC-only users, which was significantly lower than those in the smokers of 1.44 (1.16 to 1.78) and dual users of 1.38 (1.11 to 1.72). The blood Pb geometric mean differed significantly only between nonsmokers of 11.9 (10.6 to 13.3) and smokers of 15.9 (13.6 to 18.6). CONCLUSION The study revealed that smokers who completely switched to ECs and quit smoking conventional cigarettes may significantly reduce their exposure to Cd and probably Pb. IMPLICATIONS Switching to EC use is associated with a rapid and substantial decrease in the exposure to carcinogenic Cd. Exposure to Pb is probably also decreased but may be overshadowed by other factors. The study provides empirical data based not only on the analysis of generated aerosol but also on biological indicators of recent exposure-that is, the concentrations of Cd and Pb in blood, indicating EC as a potential harm-reduction device, especially regarding Cd exposure. However, in this case, dual EC use-cigarette smoking provides doubtful benefits.
Collapse
Affiliation(s)
- Adam Prokopowicz
- Chemical Hazards and Genetic Toxicology Department, Institute of Occupational Medicine and Environmental Health, Sosnowiec, Poland
| | - Andrzej Sobczak
- Department of General and Analytical Chemistry, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia, Jagiellonska Sosnowiec, Poland
| | - Magdalena Szuła-Chraplewska
- Chemical Hazards and Genetic Toxicology Department, Institute of Occupational Medicine and Environmental Health, Sosnowiec, Poland
| | - Patryk Ochota
- Chemical Hazards and Genetic Toxicology Department, Institute of Occupational Medicine and Environmental Health, Sosnowiec, Poland
| | - Leon Kośmider
- Chemical Hazards and Genetic Toxicology Department, Institute of Occupational Medicine and Environmental Health, Sosnowiec, Poland.,Department of General and Analytical Chemistry, School of Pharmacy with the Division of Laboratory Medicine in Sosnowiec, Medical University of Silesia, Jagiellonska Sosnowiec, Poland
| |
Collapse
|
33
|
Abstract
With the rapid increase in electronic cigarette (e-cig) users worldwide, secondhand exposure to e-cig aerosols has become a serious public health concern. We summarize the evidence on the effects of e-cigs on indoor air quality, chemical compositions of mainstream and secondhand e-cig aerosols, and associated respiratory and cardiovascular effects. The use of e-cigs in indoor environments leads to high levels of fine and ultrafine particles similar to tobacco cigarettes (t-cigs). Concentrations of chemical compounds in e-cig aerosols are generally lower than those in t-cig smoke, but a substantial amount of vaporized propylene glycol, vegetable glycerin, nicotine, and toxic substances, such as aldehydes and heavy metals, has been reported. Exposures to mainstream e-cig aerosols have biologic effects but only limited evidence shows adverse respiratory and cardiovascular effects in humans. Long-term studies are needed to better understand the dosimetry and health effects of exposures to secondhand e-cig aerosols.
Collapse
Affiliation(s)
- Liqiao Li
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| | - Yan Lin
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| | - Tian Xia
- Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, California 90095-1772, USA
| | - Yifang Zhu
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| |
Collapse
|
34
|
Abstract
With the rapid increase in electronic cigarette (e-cig) users worldwide, secondhand exposure to e-cig aerosols has become a serious public health concern. We summarize the evidence on the effects of e-cigs on indoor air quality, chemical compositions of mainstream and secondhand e-cig aerosols, and associated respiratory and cardiovascular effects. The use of e-cigs in indoor environments leads to high levels of fine and ultrafine particles similar to tobacco cigarettes (t-cigs). Concentrations of chemical compounds in e-cig aerosols are generally lower than those in t-cig smoke, but a substantial amount of vaporized propylene glycol, vegetable glycerin, nicotine, and toxic substances, such as aldehydes and heavy metals, has been reported. Exposures to mainstream e-cig aerosols have biologic effects but only limited evidence shows adverse respiratory and cardiovascular effects in humans. Long-term studies are needed to better understand the dosimetry and health effects of exposures to secondhand e-cig aerosols.
Collapse
Affiliation(s)
- Liqiao Li
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| | - Yan Lin
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| | - Tian Xia
- Department of Medicine, David Geffen School of Medicine, University of California, Los Angeles, California 90095-1772, USA
| | - Yifang Zhu
- Department of Environmental Health Sciences, Jonathan and Karin Fielding School of Public Health, University of California, Los Angeles, California 90095-1772, USA;
| |
Collapse
|
35
|
Ruszkiewicz JA, Zhang Z, Gonçalves FM, Tizabi Y, Zelikoff JT, Aschner M. Neurotoxicity of e-cigarettes. Food Chem Toxicol 2020; 138:111245. [PMID: 32145355 PMCID: PMC7089837 DOI: 10.1016/j.fct.2020.111245] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 02/29/2020] [Accepted: 03/03/2020] [Indexed: 02/07/2023]
Abstract
It appears that electronic cigarettes (EC) are a less harmful alternative to conventional cigarette (CC) smoking, as they generate substantially lower levels of harmful carcinogens and other toxic compounds. Thus, switching from CC to EC may be beneficial for smokers. However, recent accounts of EC- or vaping-associated lung injury (EVALI) has raised concerns regarding their adverse health effects. Additionally, the increasing popularity of EC among vulnerable populations, such as adolescents and pregnant women, calls for further EC safety evaluation. In this state-of-the-art review, we provide an update on recent findings regarding the neurological effects induced by EC exposure. Moreover, we discuss possible neurotoxic effects of nicotine and numerous other chemicals which are inherent both to e-liquids and EC aerosols. We conclude that in recognizing pertinent issues associated with EC usage, both government and scientific researchers must address this public health issue with utmost urgency.
Collapse
Affiliation(s)
- Joanna A Ruszkiewicz
- Molecular Toxicology Group, Department of Biology, University of Konstanz, Konstanz, Germany
| | - Ziyan Zhang
- Department of Molecular Pharmacology, Albert Einstein College of Medicine, Bronx, NY, United States
| | - Filipe Marques Gonçalves
- Biochemistry Graduate Program, Universidade Federal de Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Yousef Tizabi
- Department of Pharmacology, Howard University College of Medicine, Washington DC, United States
| | - Judith T Zelikoff
- Department of Environmental Medicine, New York University School of Medicine, Manhattan, NY, United States
| | - Michael Aschner
- Department of Molecular Pharmacology, Albert Einstein College of Medicine, Bronx, NY, United States.
| |
Collapse
|
36
|
Metal Concentration Assessment in the Urine of Cigarette Smokers Who Switched to Electronic Cigarettes: A Pilot Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17061877. [PMID: 32183183 PMCID: PMC7143212 DOI: 10.3390/ijerph17061877] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 11/30/2022]
Abstract
Background: E-cigarettes (ECs) seem to be a less harmful alternative for conventional cigarettes, however, very little is still known about the exposure to some elements, which are the components of this device and may contaminate the nicotine liquid. The aim of this study is to assess whether e-cigarette users are more exposed to 12 elements detected in aerosol than non-smokers and conventional cigarette smokers, using their concentrations in urine as exposure biomarkers. Methods: A cross-sectional, group-based survey was carried out using 90 volunteers classified into groups of non-smokers, EC-only users, dual EC users-cigarette smokers and cigarette-only smokers. Using inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (ETAAS), Cr, Ni, Co, Ag, In, Mn, Ba, Sr, V, Sb, Cd and Pb levels were measured in spot urine samples. Among the selected groups, a comparison was made using the analysis of covariance and correlations with EC usage pattern were assessed by multiple linear regression. Results: Element concentrations in urine of EC-users were not significantly different from the levels found in non-smokers and smokers. Only in the case of Ba, Ni and Sb was a significant correlation found in relation to some e-cigarette usage patterns. Conclusion: Transfer of the investigated elements to the EC aerosol was not found to be a substantial source of exposure in EC users who quitted smoking.
Collapse
|
37
|
Zhao D, Aravindakshan A, Hilpert M, Olmedo P, Rule AM, Navas-Acien A, Aherrera A. Metal/Metalloid Levels in Electronic Cigarette Liquids, Aerosols, and Human Biosamples: A Systematic Review. ENVIRONMENTAL HEALTH PERSPECTIVES 2020; 128:36001. [PMID: 32186411 PMCID: PMC7137911 DOI: 10.1289/ehp5686] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 02/09/2020] [Accepted: 02/27/2020] [Indexed: 05/21/2023]
Abstract
BACKGROUND Electronic cigarettes (e-cigarettes) have become popular, in part because they are perceived as a safer alternative to tobacco cigarettes. An increasing number of studies, however, have found toxic metals/metalloids in e-cigarette emissions. OBJECTIVE We summarized the evidence on metal/metalloid levels in e-cigarette liquid (e-liquid), aerosols, and biosamples of e-cigarette users across e-cigarette device systems to evaluate metal/metalloid exposure levels for e-cigarette users and the potential implications on health outcomes. METHODS We searched PubMed/TOXLINE, Embase®, and Web of Science for studies on metals/metalloids in e-liquid, e-cigarette aerosols, and biosamples of e-cigarette users. For metal/metalloid levels in e-liquid and aerosol samples, we collected the mean and standard deviation (SD) if these values were reported, derived mean and SD by using automated software to infer them if data were reported in a figure, or calculated the overall mean (mean ± SD) if data were reported only for separate groups. Metal/metalloid levels in e-liquids and aerosols were converted and reported in micrograms per kilogram and nanograms per puff, respectively, for easy comparison. RESULTS We identified 24 studies on metals/metalloids in e-liquid, e-cigarette aerosols, and human biosamples of e-cigarette users. Metal/metalloid levels, including aluminum, antimony, arsenic, cadmium, cobalt, chromium, copper, iron, lead, manganese, nickel, selenium, tin, and zinc, were present in e-cigarette samples in the studies reviewed. Twelve studies reported metal/metalloid levels in e-liquids (bottles, cartridges, open wick, and tank), 12 studies reported metal/metalloid levels in e-cigarette aerosols (from cig-a-like and tank devices), and 4 studies reported metal/metalloid levels in human biosamples (urine, saliva, serum, and blood) of e-cigarette users. Metal/metalloid levels showed substantial heterogeneity depending on sample type, source of e-liquid, and device type. Metal/metalloid levels in e-liquid from cartridges or tank/open wicks were higher than those from bottles, possibly due to coil contact. Most metal/metalloid levels found in biosamples of e-cigarette users were similar or higher than levels found in biosamples of conventional cigarette users, and even higher than those found in biosamples of cigar users. CONCLUSION E-cigarettes are a potential source of exposure to metals/metalloids. Differences in collection methods and puffing regimes likely contribute to the variability in metal/metalloid levels across studies, making comparison across studies difficult. Standardized protocols for the quantification of metal/metalloid levels from e-cigarette samples are needed. https://doi.org/10.1289/EHP5686.
Collapse
Affiliation(s)
- Di Zhao
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York, USA
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Atul Aravindakshan
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Markus Hilpert
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York, USA
| | - Pablo Olmedo
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York, USA
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
- Department of Legal Medicine and Toxicology, School of Medicine, University of Granada, Granada, Spain
| | - Ana M. Rule
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| | - Ana Navas-Acien
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, New York, USA
| | - Angela Aherrera
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland, USA
| |
Collapse
|
38
|
Belushkin M, Tafin Djoko D, Esposito M, Korneliou A, Jeannet C, Lazzerini M, Jaccard G. Selected Harmful and Potentially Harmful Constituents Levels in Commercial e-Cigarettes. Chem Res Toxicol 2019; 33:657-668. [PMID: 31859484 DOI: 10.1021/acs.chemrestox.9b00470] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
A broad range of commercially available electronic cigarette (e-cigarette) systems were tested for levels of emissions of harmful and potentially harmful constituents (HPHC), with a particular focus on the carbonyls: acetaldehyde, acrolein, and formaldehyde. The tobacco-specific nitrosamines N'-nitrosonornicotine and 4-(methylnitrosamino)-1-(3-bipyridyl)-1-butanone; the elements arsenic, cadmium, chromium, lead, and nickel; benzene; 1,3-butadiene; and benzo(a)pyrene were also quantified. The results show that except for the levels of carbonyls, all types of e-cigarettes performed in a similar manner, and emission levels for HPHCs were generally not quantifiable. However, levels of carbonyls, especially formaldehyde, were highly variable. Overall, the lowest levels of formaldehyde were observed in cartridge systems, which generally achieved substantial reductions in yields in comparison with cigarette smoke. Formaldehyde levels in open tank systems were variable; however, the median formaldehyde levels across different brands were substantially lower than the formaldehyde levels in cigarette smoke. The results for variable-power devices operated at the highest voltage confirmed existing literature data regardless of orientation and differences in puffing regimes. Furthermore, our results show that many products deliver consistent HPHC yields over a broad range of testing conditions (with minimal variability from one device to another, under a range of puffing conditions). However, some products exhibit high variability in emissions of HPHCs. The use of air blanks is further highlighted to assess nonproduct-related contributions to HPHC levels to avoid misrepresentation of the data. Overall, our results highlight that some but not all electronic cigarettes deliver low levels of carbonyls consistently across the full e-liquid depletion cycle under different test conditions. The need for further research and standardization work on assessment of variable-voltage electronic cigarettes is emphasized.
Collapse
Affiliation(s)
- Maxim Belushkin
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Donatien Tafin Djoko
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Marco Esposito
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Alexandra Korneliou
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Cyril Jeannet
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Massimo Lazzerini
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| | - Guy Jaccard
- PMI R&D, Philip Morris Products SA , Quai Jeanrenaud 5 , CH-2000 Neuchâtel , Switzerland
| |
Collapse
|
39
|
A Comparison of Flavorless Electronic Cigarette-Generated Aerosol and Conventional Cigarette Smoke on the Planktonic Growth of Common Oral Commensal Streptococci. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16245004. [PMID: 31835369 PMCID: PMC6949915 DOI: 10.3390/ijerph16245004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 12/05/2019] [Accepted: 12/06/2019] [Indexed: 02/07/2023]
Abstract
Background: Smoking is the number one predictor for the development of periodontal disease. Consequently, electronic cigarette (ECIG) use has prompted investigations into the health-related risks induced by ECIG-generated aerosol on oral commensal bacteria as compared to cigarette smoke. Since E-liquid contains fewer constituents than smoke, we hypothesize that growth media containing E-liquid or aerosol has less impact on oral commensal streptococci than cigarette smoke. Methods: Eight-hour growth curves were generated for three strains of streptococci following exposure of growth media to nicotine alone (0.05, 0.1, 0.2 mg/mL), E-liquid ± nicotine (2.3, 4.7, 7.0 µL/mL), ECIG-generated aerosol ± nicotine (25, 50, 75 puffs), or cigarette smoke (2, 5, 10, 25, 50, 75 puffs). Nicotine and E-liquid were added to the media at concentrations equivalent to vaporized amounts of 25, 50, or 75 puffs. Absorbance readings were taken at 0, 2, 4, 6, and 8 h of bacterial growth. Results: Both E-liquid and aerosol (±nicotine) had little to no effect on eight-hour streptococcal growth. In contrast, five puffs of smoke inhibited streptococcal growth. Conclusions: Smoke-treated growth media, but not E-liquid or ECIG-generated aerosol, inhibits the growth of oral commensal streptococci. A possible implication is that aerosol may induce less periodontitis than smoke.
Collapse
|
40
|
Tobore TO. On the potential harmful effects of E-Cigarettes (EC) on the developing brain: The relationship between vaping-induced oxidative stress and adolescent/young adults social maladjustment. J Adolesc 2019; 76:202-209. [DOI: 10.1016/j.adolescence.2019.09.004] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 09/07/2019] [Accepted: 09/22/2019] [Indexed: 12/20/2022]
|
41
|
Palazzolo D, Nelson JM, Hudson Z. The Use of HPLC-PDA in Determining Nicotine and Nicotine-Related Alkaloids from E-Liquids: A Comparison of Five E-Liquid Brands Purchased Locally. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E3015. [PMID: 31438499 PMCID: PMC6747407 DOI: 10.3390/ijerph16173015] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 08/15/2019] [Accepted: 08/17/2019] [Indexed: 11/16/2022]
Abstract
E-liquid manufacturers are under scrutiny concerning the purity and concentration accuracy of nicotine and the minor nicotine-related alkaloids (NRAs) packaged in their products. In this communication we report concentrations of nicotine and five NRAs (nornicotine, cotinine, anabasine, anatabine, myosmine) from locally purchased E-liquids. METHODS Five brands of E-liquids (three bottles each) were purchased locally. Additionally, three bottles of reference E-liquid were prepared. Concentrations of nicotine and NRAs from each bottle were measured by HPLC. Concentrations of these alkaloids were also determined from electronic cigarette-generated aerosol and traditional cigarette smoke. RESULTS Nicotine concentrations in E-liquid brands 1, 2, 3, 4, 5 and in the reference E-liquid were 17.8 ± 4.1, 23.2 ± 0.7, 24.0 ± 0.9, 24.9 ± 0.2, 19.7 ± 0.3 and 20.4 ± 0.1 mg/mL, respectively. Concentrations normalized to 100% of product label were 74%, 97%, 100%, 104%, 109% and 102%, respectively. E-liquid brand 1 showed significance (p < 0.001) between bottles, while the reference showed the least variability. Similar results were obtained for the NRAs. Results also indicated the NRAs in aerosol of the reference E-liquid are lower than in cigarette smoke. CONCLUSIONS The amounts of NRAs present in E-liquids and E-liquid aerosol are less compared to cigarettes, however, inconsistencies and variation in nicotine concentrations supports the need for regulatory oversight.
Collapse
Affiliation(s)
- Dominic Palazzolo
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA.
| | - John M Nelson
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA
- Department of Biology, School of Mathematics and Sciences, Lincoln Memorial University, Harrogate, TN 37752, USA
| | - Zuri Hudson
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA
| |
Collapse
|
42
|
Jain RB. Concentrations of cadmium, lead, and mercury in blood among US cigarettes, cigars, electronic cigarettes, and dual cigarette-e-cigarette users. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2019; 251:970-974. [PMID: 31234264 DOI: 10.1016/j.envpol.2019.05.041] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2018] [Revised: 02/25/2019] [Accepted: 05/09/2019] [Indexed: 05/04/2023]
Abstract
Data from National Health and Nutrition Examination Survey for 2013-2016 were used to compare observed levels of cadmium, lead, and total mercury in blood among US residents aged ≥12 years who were users of cigars, cigarettes, cigars and cigarettes, e-cigarettes and dual users of cigarettes and e-cigarettes. Total sample size available for analysis was 1139. Adjusted geometric means (AGM) among cigarette, cigar, e-cigarette, cigarette and cigar, and cigarette-e-cigarette users were comparable for blood cadmium lead, and total mercury. Cigar only users had lower AGM than cigar and cigarette users for total mercury (0.56 vs. 0.97 μg/L, p = 0.03). There is no evidence yet that can show concentrations of blood and urine cadmium, lead, and mercury among e-cigarette users are any different than among cigarette and/or dual users of cigarettes and e-cigarettes.
Collapse
|
43
|
Zhao D, Navas-Acien A, Ilievski V, Slavkovich V, Olmedo P, Adria-Mora B, Domingo-Relloso A, Aherrera A, Kleiman NJ, Rule AM, Hilpert M. Metal concentrations in electronic cigarette aerosol: Effect of open-system and closed-system devices and power settings. ENVIRONMENTAL RESEARCH 2019; 174:125-134. [PMID: 31071493 PMCID: PMC7079580 DOI: 10.1016/j.envres.2019.04.003] [Citation(s) in RCA: 59] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2019] [Revised: 03/31/2019] [Accepted: 04/05/2019] [Indexed: 05/03/2023]
Abstract
BACKGROUND Electronic cigarettes (E-cigarettes) generate aerosol containing metal contaminants. Our goals were to quantify aerosol metal concentrations and to compare the effects of power setting and device type (closed-system vs. open-system) on metal release. METHODS Aerosol samples were collected from two closed-system devices (a cigalike and pod) and two open-system devices (mods). Each open-system device was operated at three different power settings to examine the effect of device power on metal release. Concentrations of 14 metals in e-cigarette aerosol collected via droplet deposition were measured using inductively coupled plasma mass spectroscopy. Aerosol metal concentrations were reported as mass fractions (μg/kg) in the e-liquid. RESULTS For open-system device 1 (OD1), median arsenic (As), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn) concentrations increased 14, 54, 17, 30, 41, 96, 14, 81, 631, and 7-fold when the device power was increased from low (20 W) to intermediate (40 W) setting. When the power was further increased from intermediate (40 W) to high (80 W) setting, concentrations of As, Cr, Cu, Mn, Ni, and Sb did not change significantly. For open-system device 2 (OD2), Cr and Mn concentrations increased significantly when device power was increased from low (40 W) to intermediate (120 W) setting, and then decreased significantly when power was further increased from intermediate (120 W) to high (200 W) setting. Among the four devices, aerosol metal concentrations were higher for the open-system than the closed-system devices, except for aluminum (Al) and uranium (U). For Cr, median (interquartile range) concentrations (μg/kg) from the open-system devices were 2.51 (1.55, 4.23) and 15.6 (7.88, 54.5) vs. 0.39 (0.05, 0.72) and 0.41 (0.34, 0.57) for the closed-system devices. For Ni, concentrations (μg/kg) from the open-system devices were 793 (508, 1169) and 2148 (851, 3397) vs. 1.32 (0.39, 3.35) and 11.9 (10.7, 22.7) from the closed-system devices. Inhalation of 0% and 100% of samples from OD1, 7.4% and 88.9% from OD2 by typical e-cigarette users would exceed chronic minimum risk levels (MRL) of Mn and Ni, respectively. No MRL exceedance was predicted for the closed-system devices. A large fraction of users of OD1 (100%) and OD2 (77.8%) would be exposed to Ni levels higher than those from reference tobacco cigarette 3R4F. CONCLUSIONS Our findings suggest that power setting and device type affect metal release from devices to aerosol which would subsequently be inhaled by users. Metal concentrations from open-system devices first increased with device power, and then leveled off for most metals. Open-system devices generate aerosol with higher metal concentrations than closed-system devices. These findings inform tobacco regulatory science, policy makers and health professionals on potential metal health risks associated with e-cigarette use, design and manufacturing.
Collapse
Affiliation(s)
- Di Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China; Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Ana Navas-Acien
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Vesna Ilievski
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Vesna Slavkovich
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Pablo Olmedo
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA; Department of Legal Medicine and Toxicology, School of Medicine, University of Granada, Spain
| | - Bernat Adria-Mora
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Arce Domingo-Relloso
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Angela Aherrera
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Norman J Kleiman
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA
| | - Ana M Rule
- Department of Environmental Health and Engineering, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
| | - Markus Hilpert
- Department of Environmental Health Sciences, Mailman School of Public Health, Columbia University, New York, NY, USA.
| |
Collapse
|
44
|
Cuadra GA, Smith MT, Nelson JM, Loh EK, Palazzolo DL. A Comparison of Flavorless Electronic Cigarette-Generated Aerosol and Conventional Cigarette Smoke on the Survival and Growth of Common Oral Commensal Streptococci. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:E1669. [PMID: 31091650 PMCID: PMC6572406 DOI: 10.3390/ijerph16101669] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 04/26/2019] [Accepted: 05/08/2019] [Indexed: 12/15/2022]
Abstract
Background: The use of electronic cigarettes (ECIG) has become very common. Consequently, critical analysis of the biological effects of ECIG aerosol deserves attention. Flavorless ECIG aerosol is known to comprise fewer harmful constituents than cigarette smoke. Therefore, we hypothesize that aerosol has less immediate effect on the viability of oral commensal streptococci than smoke. Methods: Survival and growth of four strains of commensal streptococci were measured after exposure to flavorless ECIG aerosol ± nicotine and smoke. Peristaltic pumps were used to transport aerosol or smoke into chambers containing recently seeded colony-forming units (CFUs) of the oral commensal streptococci on agar plates. Bacterial survival and growth, based on colony counts and sizes, were determined 24 h post-exposure. Additionally, aerosol or smoke were delivered into chambers containing pre-adhered streptococci to plastic coverslips and biofilm formation was determined 24 h post-exposure via scanning electron microscopy. Results: The results suggest that flavorless aerosol ± nicotine has a modest effect on bacterial growth both as colonies on agar and as biofilms. In contrast, smoke dramatically decreased bacterial survival and growth in all parameters measured. Conclusion: Unlike cigarette smoke, flavorless ECIG aerosol has only a small effect on the survival and growth of oral commensal streptococci.
Collapse
Affiliation(s)
| | - Maxwell T Smith
- Department of Medical Laboratory Science, School of Allied Health Sciences, Lincoln Memorial University, Harrogate, TN 37752, USA.
| | - John M Nelson
- Department of Biology, School of Mathematics and Sciences, Lincoln Memorial University, Harrogate, TN 37752, USA.
| | - Emma K Loh
- Department of Biology, Muhlenberg College, Allentown, PA 18104, USA.
| | - Dominic L Palazzolo
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN 37752, USA.
| |
Collapse
|
45
|
Gaur S, Agnihotri R. Health Effects of Trace Metals in Electronic Cigarette Aerosols-a Systematic Review. Biol Trace Elem Res 2019; 188:295-315. [PMID: 29974385 DOI: 10.1007/s12011-018-1423-x] [Citation(s) in RCA: 68] [Impact Index Per Article: 13.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 06/25/2018] [Indexed: 12/25/2022]
Abstract
Electronic cigarettes (ECs) are essentially nicotine delivery devices that mimic the appearance of a conventional cigarette (CC). Lately, they have been marketed as tools for quitting smoking. Even though they are promoted as safe alternatives to CC, they are not devoid of hazardous components. Literature reveals that the EC aerosols and e-liquids are a potential source of elements that induce and promote development of chronic conditions. These include trace metals which are leached from their core assembly. Some of these metals like nickel, chromium, cadmium, tin, aluminum, and lead are potential carcinogens. They have been associated with fatal conditions like lung and sinonasal cancer. Besides, they may have adverse effects on oral tissues like periodontal ligament and mucosa where they may trigger chronic periodontitis and oral cancer. However, there is only trivial evidence related to health hazards of metals released from ECs. With this background, the present review first focuses on the structure of the ECs followed by an appraisal of the data from experimental studies about the metals released in EC aerosols and their associated health hazards.
Collapse
Affiliation(s)
- Sumit Gaur
- Department of Pedodontics and Preventive Dentistry, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Karnataka, 576104, India
| | - Rupali Agnihotri
- Department of Periodontology, Manipal College of Dental Sciences, Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Karnataka, 576104, India.
| |
Collapse
|
46
|
Zhang WZ, Butler JJ, Cloonan SM. Smoking-induced iron dysregulation in the lung. Free Radic Biol Med 2019; 133:238-247. [PMID: 30075191 PMCID: PMC6355389 DOI: 10.1016/j.freeradbiomed.2018.07.024] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 07/26/2018] [Accepted: 07/30/2018] [Indexed: 12/12/2022]
Abstract
Iron is one of the most abundant transition elements and is indispensable for almost all organisms. While the ability of iron to participate in redox chemistry is an essential requirement for participation in a range of vital enzymatic reactions, this same feature of iron also makes it dangerous in the generation of hydroxyl radicals and superoxide anions. Given the high local oxygen tensions in the lung, the regulation of iron acquisition, utilization, and storage therefore becomes vitally important, perhaps more so than in any other biological system. Iron plays a critical role in the biology of essentially every cell type in the lung, and in particular, changes in iron levels have important ramifications on immune function and the local lung microenvironment. There is substantial evidence that cigarette smoke causes iron dysregulation, with the implication that iron may be the link between smoking and smoking-related lung diseases. A better understanding of the connection between cigarette smoke, iron, and respiratory diseases will help to elucidate pathogenic mechanisms and aid in the identification of novel therapeutic targets.
Collapse
Affiliation(s)
- William Z Zhang
- Division of Pulmonary and Critical Care Medicine, Joan and Sanford I. Weill Department of Medicine, Weill Cornell Medical College, New York, NY 10021, USA; Department of Medicine, New York Presbyterian Hospital-Weill Cornell Medical Center, New York, NY 10021, USA
| | - James J Butler
- Division of Pulmonary and Critical Care Medicine, Joan and Sanford I. Weill Department of Medicine, Weill Cornell Medical College, New York, NY 10021, USA
| | - Suzanne M Cloonan
- Division of Pulmonary and Critical Care Medicine, Joan and Sanford I. Weill Department of Medicine, Weill Cornell Medical College, New York, NY 10021, USA.
| |
Collapse
|
47
|
Farsalinos KE, Rodu B. Metal emissions from e-cigarettes: a risk assessment analysis of a recently-published study. Inhal Toxicol 2018; 30:321-326. [PMID: 30384783 DOI: 10.1080/08958378.2018.1523262] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Introduction: A recent study reported levels of metal emissions in e-cigarette (EC) aerosol. Herein we present a risk assessment analysis of the published findings using total daily exposure limits. Methods: Median and 75th percentile metal concentrations in EC aerosols were used to determine the level of daily liquid consumption (g/d) that would exceed the permissible daily exposures (PDEs) defined for inhalation medications (cadmium, chromium, copper, nickel, lead, antimony and tin). For metals not having PDEs, minimal risk levels (manganese) or risk exposure levels (aluminum, iron and zinc) were converted into total daily exposure using an inhalation volume of 20 m3 (for 24 h) and 6.7 m3 (for 8 h) respectively. Results: The lowest amount of liquid consumption exceeding safety limits was found for nickel (73 g/day for median and 17 g/day for 75th percentile levels). The consumption corresponding to the 75th percentile could be associated with realistic use, although this would represent an extreme rather than average consumption. For chromium, the respective levels were 358 and 68 g/day and for lead 338 and 135 g/day. For all other metals, liquid consumption would need to be orders of magnitude higher, reaching to 1.5 million grams for aluminum. Conclusion: EC emissions contain trace levels of metals. For almost all metals, unrealistically high levels of liquid need to be consumed in order for total daily exposure to exceed established limits.
Collapse
Affiliation(s)
- Konstantinos E Farsalinos
- a Department of Cardiology , Onassis Cardiac Surgery Center , Kallithea , Greece.,b Department of Pharmacy , University of Patras , Rio-Patras , Greece.,c National School of Public Health , Athens, Greece
| | - Brad Rodu
- d Department of Medicine School of Medicine , University of Louisville , Louisville, KY , USA
| |
Collapse
|
48
|
Cobb E, Hall J, Palazzolo DL. Induction of Metallothionein Expression After Exposure to Conventional Cigarette Smoke but Not Electronic Cigarette (ECIG)-Generated Aerosol in Caenorhabditis elegans. Front Physiol 2018; 9:426. [PMID: 29740339 PMCID: PMC5925786 DOI: 10.3389/fphys.2018.00426] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 04/05/2018] [Indexed: 11/21/2022] Open
Abstract
Aim: With the invention of electronic cigarettes (ECIG), many questions have been raised regarding their safety as an alternative to smoking conventional cigarettes. Conventional cigarette smoke contains a variety of toxicants including heavy metals. However, ECIG-generated aerosol contains only trace amounts of metals, adding to the argument for it being a safer alternative. In response to heavy metal exposure, metallothioneins are induced in cells to help store the metal, detoxify the body, and are also known responders to oxidative stress. In an attempt to add to the evaluation of the safety of ECIGs, metallothionein expression was quantified using the nematode Caenorhabditis elegans as an assessment of stress induced cellular damage caused by exposure. Methods: Adult nematodes were exposed to either ECIG aerosol or conventional cigarette smoke at doses of 15, 30, and 45 puffs, the equivalent of one, two, and three cigarettes, respectively. Movement, survival, and stress-induced sleep were assessed for up to 24 h after exposure. Relative expression levels for mtl-1 and mtl-2, C. elegans metallothionein genes, were analyzed after 1, 5, and 24 h post exposure using quantitative RT-PCR. Results: Nematodes exposed to conventional cigarette smoke underwent stress-induced sleep in a dose dependent manner with animals recovering to values within the range of air control after 5 h post exposure. Those exposed to ECIG aerosol did not undergo stress-induced sleep and were indistinguishable from controls. The expression of mtl-1 increased in a dose and time dependent manner in C. elegans exposed to conventional cigarette smoke, with a maximum expression observed at 5 h post exposure of 45 puffs. No induction of mtl-2 was observed in any animals. Additionally, ECIG aerosol did not induce expression of mtl-1 and mtl-2 at levels different than those of untreated. Conclusion: ECIG aerosol failed to induce a stress response in C. elegans. In contrast, conventional cigarette smoke induced the production of mtl-1 in a manner that correlates with the induction of stress-induced sleep suggesting a stress response to damage. The lack of cellular stress response to ECIG aerosol suggests it may be a safer alternative to conventional cigarettes.
Collapse
Affiliation(s)
- Eric Cobb
- School of Mathematics and Sciences, Lincoln Memorial University, Harrogate, TN, United States.,DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN, United States
| | - Julie Hall
- Department of Biology, School of Mathematics and Sciences, Lincoln Memorial University, Harrogate, TN, United States
| | - Dominic L Palazzolo
- Department of Physiology, DeBusk College of Osteopathic Medicine, Lincoln Memorial University, Harrogate, TN, United States
| |
Collapse
|
49
|
Kamilari E, Farsalinos K, Poulas K, Kontoyannis CG, Orkoula MG. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry. Food Chem Toxicol 2018; 116:233-237. [PMID: 29679608 DOI: 10.1016/j.fct.2018.04.035] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 03/28/2018] [Accepted: 04/16/2018] [Indexed: 11/28/2022]
Abstract
Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health.
Collapse
Affiliation(s)
- Eleni Kamilari
- Laboratory of Pharmaceutical Analysis, Department of Pharmacy, University of Patras, Greece
| | - Konstantinos Farsalinos
- Laboratory of Molecular Biology and Immunology, Department of Pharmacy, University of Patras, Greece; Onassis Cardiac Surgery Center, Athens, Greece
| | - Konstantinos Poulas
- Laboratory of Molecular Biology and Immunology, Department of Pharmacy, University of Patras, Greece
| | - Christos G Kontoyannis
- Laboratory of Pharmaceutical Analysis, Department of Pharmacy, University of Patras, Greece; Institute of Chemical Engineering Sciences/Foundation for Research and Technology Hellas, Patras, Greece
| | - Malvina G Orkoula
- Laboratory of Pharmaceutical Analysis, Department of Pharmacy, University of Patras, Greece.
| |
Collapse
|
50
|
Brief Report: Lead Levels in Selected Electronic Cigarettes from Canada and the United States. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2018; 15:ijerph15010154. [PMID: 29351185 PMCID: PMC5800253 DOI: 10.3390/ijerph15010154] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Revised: 01/12/2018] [Accepted: 01/17/2018] [Indexed: 11/16/2022]
Abstract
Few published studies have investigated the presence of lead in the e-liquid of electronic nicotine delivery systems (ENDS). Lead inhalation is associated with increased risk of stroke, heart disease, and other diseases. This study used a novel application of graphite furnace technology to compare the concentration of lead between e-liquids of different packaging and product designs using e-liquids that are or were commercially available in the United States and Canada. Eleven nicotine-free disposable ENDS devices and 12 bottled refill solutions that contained nicotine were purchased from retailers in Canada and the United States between 2015 and 2017. E-liquids extracted from the disposable products and individual containers were analyzed for lead content by graphite furnace using atomic absorption detection. The lead concentration of open-wick ENDS devices ranged from 25.2 ppb to 838.4 ppb, with a standard deviation of 187.4 ppb. None of the bottled e-liquids contained quantifiable levels of lead. This study found that quantifiable levels of lead are present in certain disposable e-cigarette devices, and there is evidence from this study that the design of ENDS devices may contribute to lead exposure. These findings suggest that lead testing should be incorporated into future chemical analyses of ENDS devices.
Collapse
|