1
|
Ulanova A, Mansfeldt C. EcoGenoRisk: Developing a computational ecological risk assessment tool for synthetic biology. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 346:123647. [PMID: 38402941 DOI: 10.1016/j.envpol.2024.123647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 02/27/2024]
Abstract
The expanding field of synthetic biology (synbio) supports new opportunities in the design of targeted bioproducts or modified microorganisms. However, this rapid development of synbio products raises concerns surrounding the potential risks of modified microorganisms contaminating unintended environments. These potential invasion risks require new bioinformatic tools to inform the design phase. EcoGenoRisk is a newly constructed computational risk assessment tool for invasiveness that aims to predict where synbio microorganisms may establish a population by screening for habitats of genetically similar microorganisms. The first module of the tool identifies genetically similar microorganisms and potential ecological relationships such as competition, mutualism, and inhibition. In total, 520 archaeal and 32,828 bacterial complete assembly genomes were analyzed to test the specificity and accuracy of the tool as well as to characterize the enzymatic profiles of different taxonomic lineages. Additionally, ecological relationships were analyzed to determine which would result in the greatest potential overlap between shared functional profiles. Notably, competition displayed the significantly highest overlap of shared functions between compared genomes. Overall, EcoGenoRisk is a flexible software pipeline that assists environmental risk assessors to query large databases of known microorganisms and prioritize follow-up bench scale studies.
Collapse
Affiliation(s)
- Anna Ulanova
- University of Colorado Boulder, Department of Civil, Environmental, and Architectural Engineering, 1111 Engineering Drive, Boulder, CO, 80309, USA; University of Colorado Boulder, Environmental Engineering Program, 4001 Discovery Drive, Boulder, CO, 80303, USA
| | - Cresten Mansfeldt
- University of Colorado Boulder, Department of Civil, Environmental, and Architectural Engineering, 1111 Engineering Drive, Boulder, CO, 80309, USA; University of Colorado Boulder, Environmental Engineering Program, 4001 Discovery Drive, Boulder, CO, 80303, USA.
| |
Collapse
|
2
|
Rehm C, Kolm C, Pleininger S, Heger F, Indra A, Reischer GH, Farnleitner AAH, Kirschner AKT. Vibrio cholerae-An emerging pathogen in Austrian bathing waters? Wien Klin Wochenschr 2023; 135:597-608. [PMID: 37530997 PMCID: PMC10651712 DOI: 10.1007/s00508-023-02241-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 06/11/2023] [Indexed: 08/03/2023]
Abstract
Vibrio cholerae, an important human pathogen, is naturally occurring in specific aquatic ecosystems. With very few exceptions, only the cholera-toxigenic strains belonging to the serogroups O1 and O139 are responsible for severe cholera outbreaks with epidemic or pandemic potential. All other nontoxigenic, non-O1/non-O139 V. cholerae (NTVC) strains may cause various other diseases, such as mild to severe infections of the ears, of the gastrointestinal and urinary tracts as well as wound and bloodstream infections. Older, immunocompromised people and patients with specific preconditions have an elevated risk. In recent years, worldwide reports demonstrated that NTVC infections are on the rise, caused amongst others by elevated water temperatures due to global warming.The aim of this review is to summarize the knowledge gained during the past two decades on V. cholerae infections and its occurrence in bathing waters in Austria, with a special focus on the lake Neusiedler See. We investigated whether NTVC infections have increased and which specific environmental conditions favor the occurrence of NTVC. We present an overview of state of the art methods that are currently available for clinical and environmental diagnostics. A preliminary public health risk assessment concerning NTVC infections related to the Neusiedler See was established. In order to raise awareness of healthcare professionals for NTVC infections, typical symptoms, possible treatment options and the antibiotic resistance status of Austrian NTVC isolates are discussed.
Collapse
Affiliation(s)
- Carmen Rehm
- Division Water Quality and Health, Karl-Landsteiner University of Health Sciences, Krems, Austria
- Institute for Hygiene and Applied Immunology - Water Microbiology, Medical University Vienna, Vienna, Austria
- Interuniversity Cooperation Centre Water & Health
| | - Claudia Kolm
- Division Water Quality and Health, Karl-Landsteiner University of Health Sciences, Krems, Austria
- Interuniversity Cooperation Centre Water & Health
- Institute for Chemical, Environmental and Bioscience Engineering, Research Group Microbiology and Molecular Diagnostics 166/5/3, Technische Universität Wien, Vienna, Austria
| | - Sonja Pleininger
- Institute for Medical Microbiology and Hygiene, National Reference Centre for Vibrio cholerae, Austrian Agency for Health and Food Safety (AGES), Vienna, Austria
| | - Florian Heger
- Institute for Medical Microbiology and Hygiene, National Reference Centre for Vibrio cholerae, Austrian Agency for Health and Food Safety (AGES), Vienna, Austria
| | - Alexander Indra
- Institute for Medical Microbiology and Hygiene, National Reference Centre for Vibrio cholerae, Austrian Agency for Health and Food Safety (AGES), Vienna, Austria
- Paracelsus Medical University Salzburg, Salzburg, Austria
| | - Georg H Reischer
- Interuniversity Cooperation Centre Water & Health
- Institute for Chemical, Environmental and Bioscience Engineering, Research Group Microbiology and Molecular Diagnostics 166/5/3, Technische Universität Wien, Vienna, Austria
| | - Andreas A H Farnleitner
- Division Water Quality and Health, Karl-Landsteiner University of Health Sciences, Krems, Austria
- Interuniversity Cooperation Centre Water & Health
- Institute for Chemical, Environmental and Bioscience Engineering, Research Group Microbiology and Molecular Diagnostics 166/5/3, Technische Universität Wien, Vienna, Austria
| | - Alexander K T Kirschner
- Division Water Quality and Health, Karl-Landsteiner University of Health Sciences, Krems, Austria.
- Institute for Hygiene and Applied Immunology - Water Microbiology, Medical University Vienna, Vienna, Austria.
- Interuniversity Cooperation Centre Water & Health, .
| |
Collapse
|
3
|
Chatziprodromidou IP, Savoglidou I, Stavrou V, Vantarakis G, Vantarakis A. Surveillance of Legionella spp. in Open Fountains: Does It Pose a Risk? Microorganisms 2022; 10:2458. [PMID: 36557711 PMCID: PMC9781103 DOI: 10.3390/microorganisms10122458] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2022] [Revised: 11/21/2022] [Accepted: 12/03/2022] [Indexed: 12/14/2022] Open
Abstract
Clusters of outbreaks or cases of legionellosis have been linked to fountains. The function of fountains, along with their inadequate design and poor sanitation, in combination with the warm Mediterranean climate, can favor the proliferation of Legionella in water systems. Public fountains in Mediterranean cities may pose a significant risk for public health due to the aerosolization of water. Nevertheless, few studies have been conducted on Legionella and the risk of infection in humans through fountains. In our study, the presence and quantity of Legionella spp. in fifteen external public fountains were investigated. Two samplings were performed in two different periods (dry and wet). Sixty samples were collected, quantified and analyzed with a culture ISO method. The operation of all fountains was evaluated twice using a standardized checklist. In accordance with their operation, a ranking factor (R factor) was suggested. Finally, based on these results, a quantitative microbial risk assessment was performed. Thirty water samples taken from the fountains (100%) during the dry sampling period were positive for Legionella (mean log concentration: 3.64 ± 0.45 cfu/L), whereas 24 water samples taken from the fountains during the wet period were Legionella-positive (mean log concentration: 2.36 ± 1.23 cfu/L). All fountains were classified as unsatisfactory according to the checklist for the evaluation of their function. A statistically significant correlation was found between Legionella concentration and the assessment score. The risk of Legionella infection was estimated in both periods, with higher risk in the dry period. The surveillance and risk assessment of Legionella spp. in the fountains of Patras confirmed a high prevalence and a high risk to public health.
Collapse
Affiliation(s)
- Ioanna P. Chatziprodromidou
- Environmental Microbiology, Department of Public Health, Medical School, University of Patras, 265 04 Patras, Greece
| | | | | | | | - Apostolos Vantarakis
- Environmental Microbiology, Department of Public Health, Medical School, University of Patras, 265 04 Patras, Greece
| |
Collapse
|
4
|
Kermani M, Chegini Z, Mirkalantari S, Norzaee S. Assessment of the risk of Legionella pneumophila in water distribution systems in hospitals of Tehran city. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:842. [PMID: 36175694 DOI: 10.1007/s10661-022-10469-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 09/10/2022] [Indexed: 06/16/2023]
Abstract
When a sensitive host inhales aerosols containing these bacteria, Legionella infection occurs. Therefore, monitoring and assessing Legionella in the environment and water distribution systems of such places are critical due to the prone population in hospitals. However, the health risks of Legionella bacteria in the environment are not adequately evaluated. In this study, for hospitalized patients, we performed a quantitative health risk assessment of Legionella in selected hospitals in Tehran city using two scenarios of shower and toilet faucet exposure. This study identified Legionella in 38 cases (38%) out of 100 samples collected from toilet faucets and showers in 8 hospitals. The information gathered was used for quantitative microbial risk assessment (QMRA). The microbial load transmitted by inhalation was calculated using the concentration of Legionella in water. Other exposure parameters (inhalation rate and exposure time) were obtained using information from other studies and the median length of hospital stay (3.6 days). The exponential model was used to estimate the risk of infection (γ = 0.06) due to Legionella pneumophila (L. pneumophila) inhalation for each exposure event. For the mean concentration obtained for Legionella (103 CFU/L), the risk of infection for toilet faucets and showers was in the range of 0.23-2.3 and 3.5-21.9, respectively, per 10,000 hospitalized patients. The results were compared with the tolerable risk level of infection determined by the US EPA and WHO. The risk values exceeded the WHO values for waterborne pathogens in hospitals in both exposure scenarios. As a result, our QMRA results based on monitoring data showed that despite using treated water (from distribution networks in the urban areas) by hospitals, 38% of the samples were contaminated with Legionella, and faucets and showers can be sources of Legionella transmission. Hence, to protect the health of hospitalized patients, the risk of Legionella infection should be considered.
Collapse
Affiliation(s)
- Majid Kermani
- Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran
| | - Zahra Chegini
- Department of Microbiology, School of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran
| | - Shiva Mirkalantari
- Department of Microbiology, School of Medicine, Iran University of Medical Sciences, Tehran, Iran.
| | - Samira Norzaee
- Research Center for Environmental Health Technology, Iran University of Medical Sciences, Tehran, Iran.
- Department of Environmental Health Engineering, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
5
|
Ortí-Lucas RM, Luciano E. New immunomagnetic separation method to analyze risk factors for Legionella colonization in health care centres. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2022; 32:744-750. [PMID: 35264765 PMCID: PMC8906530 DOI: 10.1038/s41370-022-00421-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 02/09/2022] [Accepted: 02/10/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND It's pivotal to control the presence of legionella in sanitary structures. So, it's important to determine the risk factors associated with Legionella colonization in health care centres. In recent years that is why new diagnostic techniques have been developed. OBJECTIVE To evaluate risks factors for Legionella colonization using a novel and more sensitive Legionella positivity index. METHODS A total of 204 one-litre water samples (102 cold water samples and 102 hot water samples), were collected from 68 different sampling sites of the hospital water system and tested for Legionella spp. by two laboratories using culture, polymerase chain reaction and a method based on immunomagnetic separation (IMS). A Legionella positivity index was defined to evaluate Legionella colonization and associated risk factors in the 68 water samples sites. We performed bivariate analyses and then logistic regression analysis with adjustment of potentially confounding variables. We compared the performance of culture and IMS methods using this index as a new gold standard to determine if rapid IMS method is an acceptable alternative to the use of slower culture method. RESULTS Based on the new Legionella positivity index, no statistically significant differences were found neither between laboratories nor between methods (culture, IMS). Positivity was significantly correlated with ambulatory health assistance (p = 0.05) and frequency of use of the terminal points. The logistic regression model revealed that chlorine (p = 0.009) and the frequency of use of the terminal points (p = 0.001) are predictors of Legionella colonization. Regarding this index, the IMS method proved more sensitive (69%) than culture method (65.4%) in hot water samples. SIGNIFICANCE We showed that the frequency of use of terminal points should be considered when examining environmental Legionella colonization, which can be better evaluated using the provided Legionella positivity index. This study has implications for the prevention of Legionnaires' disease in hospital settings.
Collapse
Affiliation(s)
- Rafael Manuel Ortí-Lucas
- Research group on Public Health and Patient Safety, Universidad Católica de Valencia San Vicente Mártir, Valencia, Spain.
- Department of Preventive Medicine, Hospital Clínico Universitario de Valencia, Valencia, Spain.
| | - Eugenio Luciano
- Department of Preventive Medicine, Hospital Clínico Universitario de Valencia, Valencia, Spain.
- Escuela de Doctorado, Universidad Católica de Valencia San Vicente Mártir, Valencia, Spain.
| |
Collapse
|
6
|
Atmospheric dispersion and transmission of Legionella from wastewater treatment plants: A 6-year case-control study. Int J Hyg Environ Health 2021; 237:113811. [PMID: 34311418 DOI: 10.1016/j.ijheh.2021.113811] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/17/2021] [Accepted: 07/13/2021] [Indexed: 01/25/2023]
Abstract
Legionnaires Disease incidence has risen in the Netherlands in recent years. For the majority of the cases, the source of infection is never identified. Two Dutch wastewater treatment plants (WWTPs) have previously been identified as source of outbreaks of Legionnaires Disease (LD) among local residents. The objective of this study is to examine if LD patients in the Netherlands are more exposed to aerosols originating from WWTPs than controls. METHODS An atmospheric dispersion model was used to generate nationwide exposure maps of aerosols from 776 WWTPs in the Netherlands. Municipal sewage treatment plants and industrial WWTPs were both included. Exposure of LD cases and controls at the residential address was compared, in a matched case-control design using a conditional logistic regression. Cases were notified LD cases with onset of disease in the period 2013-2018 in the Netherlands (n = 1604). RESULTS Aerosols dispersed over a large part of the Netherlands, but modelled concentrations are estimated to be elevated in close proximity to WWTPs. A statistically significant association was found between LD and the calculated annual average aerosol concentrations originating from WWTPs (odds-ratio: 1.32 (1.06-1.63)). This association remained significant when the two outbreak-related WWTPs were removed from the analysis (odds-ratio: 1.28 (1.03-1.58)). CONCLUSION LD cases were more exposed to aerosols from WWTPs than controls. This indicates that exposure to aerosols dispersed from WWTPs caused Legionnaires Disease in residents living near WWTPs in the period 2013-2018. In order to investigate which characteristics of WWTPs are associated with an increased LD risk, the WWTP database should be updated and more data is needed on the presence and survival of aerosolized Legionella bacteria to improve the Legionella dispersion modelling. Furthermore, it is recommended to further investigate how aerosol dispersion of WWTPs can effectively be reduced in order to reduce the potential health risk.
Collapse
|
7
|
Basavaraju S, Aswathanarayan JB, Basavegowda M, Somanathan B. Coronavirus: occurrence, surveillance, and persistence in wastewater. ENVIRONMENTAL MONITORING AND ASSESSMENT 2021; 193:508. [PMID: 34302225 PMCID: PMC8300075 DOI: 10.1007/s10661-021-09303-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2020] [Accepted: 07/12/2021] [Indexed: 05/02/2023]
Abstract
The coronavirus disease (COVID-19) outbreak reported in China in December 2019 has spread throughout the world. The WHO declared it as a pandemic in March 2020. The pandemic severely affected public health and the global economy. Many studies conducted on the coronavirus have helped us to elucidate its pathogenicity and pathophysiology. However, it is important to study the behavior of the pathogen in the environment to develop effective control measures. While studying the persistence and transmission of viruses in drinking water and wastewater systems, a low concentration of coronavirus and its nucleic acids have been detected in municipal wastewaters. This could be due to their high susceptibilities to degradation in aqueous environments. Epidemiological study on coronaviruses in wastewater will serve two purposes, i.e., in early detection of outbreak and in identifying asymptomatic carriers. In such cases, the epidemiological study will help in early detection of the presence of the virus in the community. Secondly, it will help in knowing if there are asymptomatic carriers, as such people do not show any signs of symptoms but shed the viruses in feces. The present review focuses on the epidemiological surveillance of wastewater for coronaviruses, as in recent years these are increasingly causing global pandemics. In this review we have discussed, the four pertinent areas of coronavirus study: (1) occurrence of coronavirus in wastewater, (2) wastewater based epidemiological surveillance of coronaviruses, (3) epidemiological surveillance tools used for detection of coronaviruses in sewage, and (4) persistence and sustainability of coronaviruses in wastewater.
Collapse
Affiliation(s)
| | - Jamuna Bai Aswathanarayan
- Department of Microbiology, Faculty of Life Science, JSS Academy of Higher Education, Mysore, 570015, India.
| | - Madhu Basavegowda
- Department of Community Medicine, JSS Medical College, JSS AHER, Mysore, 570015, India
| | | |
Collapse
|
8
|
Allegra S, Riffard S, Leclerc L, Girardot F, Stauffert M, Forest V, Pourchez J. A valuable experimental setup to model exposure to Legionella's aerosols generated by shower-like systems. WATER RESEARCH 2020; 172:115496. [PMID: 31972415 DOI: 10.1016/j.watres.2020.115496] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2019] [Revised: 01/07/2020] [Accepted: 01/08/2020] [Indexed: 06/10/2023]
Abstract
The mechanism underlying Legionella aerosolization and entry into the respiratory tract remains poorly documented. In previous studies, we characterized the aerodynamic behaviour of Legionella aerosols and assessed their regional deposition within the respiratory tract using a human-like anatomical model. The aim of this study was to assess whether this experimental setup could mimic the exposure to bioaerosols generated by showers. To achieve this objective we performed experiments to measure the mass median aerodynamic diameter (MMAD) as well as the emitted dose and the physiological state of the airborne bacteria generated by a shower and two nebulizers (vibrating-mesh and jet nebulizers). The MMADs of the dispersed bioaerosols were characterized using a 12-stage cascade low-pressure impactor. The amount of dispersed airborne bacteria from a shower was quantified using a Coriolis® Delta air sampler and compared to the airborne bacteria reaching the thoracic region in the experimental setup. The physiological state and concentration of airborne Legionella were assessed by qPCR for total cells, culture for viable and cultivable Legionella (VC), and flow cytometry for viable but non-cultivable Legionella (VBNC). In summary, the experimental setup developed appears to mimic the bioaerosol emission of a shower in terms of aerodynamic size distribution. Compared to the specific case of a shower used as a reference in this study, the experimental setup developed underestimates by 2 times (when the jet nebulizer is used) or overestimates by 43 times (when the vibrating-mesh nebulizer is used) the total emitted dose of airborne bacteria. To our knowledge, this report is the first showing that an experimental model mimics so closely an exposure to Legionella aerosols produced by showers to assess human lung deposition and infection in well-controlled and safe conditions.
Collapse
Affiliation(s)
- Séverine Allegra
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France.
| | - Serge Riffard
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Lara Leclerc
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| | - Françoise Girardot
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Magalie Stauffert
- University of Lyon, University Jean Monnet of Saint-Etienne, CNRS, EVS-ISTHME UMR 5600, F-42023, Saint-Etienne, France
| | - Valérie Forest
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| | - Jérémie Pourchez
- Mines Saint-Etienne, University of Lyon, University Jean Monnet of Saint-Etienne, INSERM, U 1059 Sainbiose, Centre CIS, F-42023, Saint-Etienne, France
| |
Collapse
|
9
|
An Advanced Risk Modeling Method to Estimate Legionellosis Risks Within a Diverse Population. WATER 2019. [DOI: 10.3390/w12010043] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Quantitative microbial risk assessment (QMRA) is a computational science leveraged to optimize infectious disease controls at both population and individual levels. Often, diverse populations will have different health risks based on a population’s susceptibility or outcome severity due to heterogeneity within the host. Unfortunately, due to a host homogeneity assumption in the microbial dose-response models’ derivation, the current QMRA method of modeling exposure volume heterogeneity is not an accurate method for pathogens such as Legionella pneumophila. Therefore, a new method to model within-group heterogeneity is needed. The method developed in this research uses USA national incidence rates from the Centers for Disease Control and Prevention (CDC) to calculate proxies for the morbidity ratio that are descriptive of the within-group variability. From these proxies, an example QMRA model is developed to demonstrate their use. This method makes the QMRA results more representative of clinical outcomes and increases population-specific precision. Further, the risks estimated demonstrate a significant difference between demographic groups known to have heterogeneous health outcomes after infection. The method both improves fidelity to the real health impacts resulting from L. pneumophila infection and allows for the estimation of severe disability-adjusted life years (DALYs) for Legionnaires’ disease, moderate DALYs for Pontiac fever, and post-acute DALYs for sequela after recovering from Legionnaires’ disease.
Collapse
|
10
|
Public Health Risks Associated with Heavy Metal and Microbial Contamination of Drinking Water in Australia. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16203982. [PMID: 31635303 PMCID: PMC6843933 DOI: 10.3390/ijerph16203982] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 10/16/2019] [Accepted: 10/16/2019] [Indexed: 01/15/2023]
Abstract
Recently in Australia concerns have been raised regarding the contamination of municipal drinking water supplies with lead. This is of particular concern to children due to the impact of lead exposure on cognitive development and as such these findings have received much media attention. The response from legislators has been swift, and The Victorian School Building Authority has announced that all new schools and school upgrade works will only use lead-free tapware and piping systems. However, while the immediate replacement of lead-containing brass fittings may seem a logical and obvious response, it does not consider the potential implications on microbial contamination. This is particularly concerning given the increasing public health threat posed by opportunistic premise plumbing pathogens (OPPPs). This commentary explores this public health risk of lead exposure from plumbing materials compared to the potential public health risks from OPPPs. Non-tuberculous mycobacterium was chosen as the example OPPP, and the influence on plumbing material and its public health burden in Australia is explored. This commentary highlights the need for future research into the influence of plumbing material on OPPPs prior to any changes in legislation regarding plumbing material.
Collapse
|
11
|
Socio-Economic and Environmental Factors Related to Spatial Differences in Human Non-Tuberculous Mycobacterial Diseases in the Czech Republic. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16203969. [PMID: 31627484 PMCID: PMC6843547 DOI: 10.3390/ijerph16203969] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Accepted: 10/16/2019] [Indexed: 02/07/2023]
Abstract
Non-tuberculous mycobacteria (NTM) are ubiquitous environmental bacteria that can induce pulmonary and non-pulmonary diseases in susceptible persons. It is reported that the prevalence of NTM diseases is increasing in developed countries, but this differs by regions and countries. NTM species distribution and the rate of diseases caused by NTM vary widely in the historical territories of Moravia and Silesia (Czech Republic). This epidemiologic study of NTM diseases covers the period 2012–2018, reviews isolates obtained from patients with clinical disease and investigates correlations with related socio-economic and environmental factors. Individual NTM patients were included only once during the studied period and results were presented as incidence rate per year. The most frequently isolated NTM meeting the microbiological and clinical criteria in the study were the Mycobacterium avium-intracellulare complex, followed by Mycobacterium kansasii and Mycobacteriumxenopi. A previously described endemic incidence of M.kansasii in the Karviná district and M.xenopi in the Ostrava district was also observed in this study. The incidence of NTM patients in the whole studied territory was 1.10/100,000 inhabitants (1.33/100,000 in men and 0.88/100,000 in women). The annual incidence of lymphadenitis in children (≤5 years of age) was 2.35/100,000 of the population of children during the 7 year period but increased in the year 2018 to 5.95/100,000. The rate of human tuberculosis in the studied area was 1.97/100,000 inhabitants. The incidence of NTM pulmonary diseases correlated with a lower socio-economic status (r = 0.63) and a higher concentration of benzo[a]pyrene pollution in the air (r = 0.64).
Collapse
|
12
|
Dowdell K, Haig SJ, Caverly LJ, Shen Y, LiPuma JJ, Raskin L. Nontuberculous mycobacteria in drinking water systems - the challenges of characterization and risk mitigation. Curr Opin Biotechnol 2019; 57:127-136. [PMID: 31003169 DOI: 10.1016/j.copbio.2019.03.010] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2018] [Revised: 03/05/2019] [Accepted: 03/05/2019] [Indexed: 12/18/2022]
Abstract
Nontuberculous mycobacteria (NTM) pulmonary infections are a growing concern worldwide, with a disproportionate incidence in persons with pre-existing health conditions. NTM have frequently been found in municipally-treated drinking water and building plumbing, leading to the hypothesis that an important source of NTM exposure is drinking water. The identification and quantification of NTM in environmental samples are complicated by genetic variability among NTM species, making it challenging to determine if clinically relevant NTM are present. Additionally, their unique cellular features and lifestyles make NTM and their nucleic acids difficult to recover. This review highlights a recent work focused on quantification and characterization of NTM and on understanding the influence of source water, treatment plants, distribution systems, and building plumbing on the abundance of NTM in drinking water.
Collapse
Affiliation(s)
- Katherine Dowdell
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Sarah-Jane Haig
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA; Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Lindsay J Caverly
- Department of Pediatrics, University of Michigan, Ann Arbor, MI, USA
| | - Yun Shen
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - John J LiPuma
- Department of Pediatrics, University of Michigan, Ann Arbor, MI, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|
13
|
Real-Time Continuous Surveillance of Temperature and Flow Events Presents a Novel Monitoring Approach for Hospital and Healthcare Water Distribution Systems. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16081332. [PMID: 31013887 PMCID: PMC6518245 DOI: 10.3390/ijerph16081332] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 04/01/2019] [Accepted: 04/07/2019] [Indexed: 01/27/2023]
Abstract
Within hospitals and healthcare facilities opportunistic premise plumbing pathogens (OPPPs) are a major and preventable cause of healthcare-acquired infections. This study presents a novel approach for monitoring building water quality using real-time surveillance of parameters measured at thermostatic mixing valves (TMVs) across a hospital water distribution system. Temperature was measured continuously in real-time at the outlet of 220 TMVs located across a hospital over a three-year period and analysis of this temperature data was used to identify flow events. This real-time temperature and flow information was then compared with microbial water quality. Water samples were collected randomly from faucets over the three-year period. These were tested for total heterotrophic bacteria, Legionella spp. and L. pneumophila. A statistically significant association with total heterotrophic bacteria concentrations and the number of flow events seven days prior (rs[865] = -0.188, p < 0.01) and three days prior to sampling (rs[865] = -0.151, p < 0.01) was observed, with decreased heterotrophic bacteria linked to increased flushing events. Only four samples were positive for Legionella and statistical associations could not be determined; however, the environmental conditions for these four samples were associated with higher heterotrophic counts. This study validated a simple and effective remote monitoring approach to identifying changes in water quality and flagging high risk situations in real-time. This provides a complementary surveillance strategy that overcomes the time delay associated with microbial culture results. Future research is needed to explore the use of this monitoring approach as an indicator for different opportunistic pathogens.
Collapse
|