1
|
Bhuiyan MSA, Gupta SD, Silip JJ, Talukder S, Haque MH, Forwood JK, Sarker S. Current trends and future potential in the detection of avian coronaviruses: An emphasis on sensors-based technologies. Virology 2025; 604:110399. [PMID: 39884161 DOI: 10.1016/j.virol.2025.110399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 12/04/2024] [Accepted: 01/08/2025] [Indexed: 02/01/2025]
Abstract
Infectious bronchitis virus (IBV), an avian coronavirus, member of the genus Gammacoronavirus, poses significant threats to poultry health, causing severe respiratory, reproductive, and renal infections. The genetic diversity of IBV, driven by mutations, recombination and deletions, has led to the emergence of numerous serotypes and genotypes, complicating both diagnosis and control measures. Rapid and accurate diagnostic tools are essential for effective disease management and minimizing economic losses. Conventional diagnostic methods, such as PCR, virus isolation, and serological assays, are hindered by limitations in sensitivity, specificity, and turnaround time. In contrast, innovative biosensor platforms employing advanced detection mechanisms-including electrochemical, optical, and piezoelectric sensors-offer a transformative solution. These technologies provide portable, highly sensitive, and rapid diagnostic platforms for IBV detection. Beyond addressing the challenges of conventional methods, these biosensor-based approaches facilitate real-time monitoring and enhance disease surveillance. This review highlights the transformative potential of biosensors and their integration into diagnostic strategies for avian coronavirus infections, presenting them as a promising alternative for precise and efficient IBV detection.
Collapse
Affiliation(s)
- Md Safiul Alam Bhuiyan
- Faculty of Sustainable Agriculture, Livestock Production, University Malaysia Sabah, Sandakan, Sabah, Malaysia
| | - Suman Das Gupta
- School of Agricultural, Environmental and Veterinary Sciences, Faculty of Science and Health Charles Sturt University, Wagga Wagga, 2650, Australia; Gulbali Institute, Charles Sturt University, Wagga Wagga, NSW, 2650, Australia
| | - Juplikely James Silip
- Faculty of Sustainable Agriculture, Livestock Production, University Malaysia Sabah, Sandakan, Sabah, Malaysia
| | - Saranika Talukder
- College of Public Health, Medical and Veterinary Sciences, James Cook University, Townsville, QLD, 4811, Australia
| | - Md Hakimul Haque
- College of Public Health, Medical and Veterinary Sciences, James Cook University, Townsville, QLD, 4811, Australia; Rajshahi University, Faculty of Veterinary and Animal Sciences, Department of Veterinary and Animal Sciences, Rajshahi, 6205, Bangladesh
| | - Jade K Forwood
- Gulbali Institute, Charles Sturt University, Wagga Wagga, NSW, 2650, Australia
| | - Subir Sarker
- Biomedical Sciences and Molecular Biology, College of Medicine and Dentistry, James Cook University, Townsville, QLD, 4811, Australia; Australian Institute of Tropical Health and Medicine, James Cook University, Townsville, QLD, 4811, Australia.
| |
Collapse
|
2
|
Mohammadi M, Asvar Z, Solhjoo SP, Sarikhanikhorrami M, Abadi HG, Ghazizadeh S, Mahmoodi H, Habibolah NK, Moradi O, Kesharwani P, Amani AM, Sahebkar A. COVID-19 diagnosis on the basis of nanobiosensors' prompt interactivity: A holistic review. Pathol Res Pract 2024; 262:155565. [PMID: 39226801 DOI: 10.1016/j.prp.2024.155565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/14/2024] [Accepted: 08/28/2024] [Indexed: 09/05/2024]
Abstract
The fast spread and severe consequences of novel coronavirus disease 2019 (COVID-19) have once again underscored the critical necessity of early detection of viral infections. Several serology-based techniques, including as point-of-care assays and high-throughput enzyme immunoassays that support the diagnosis of COVID-19 are utilized in the detection and identification of coronaviruses. A rapid, precise, simple, affordable, and adaptable diagnostic tool is required for controlling COVID-19 as well as for outbreak management, since the calculation and monitoring of viral loads are crucial for predicting the infection stage and recovery time. Nowadays, the most popular method for diagnosing COVID-19 is reverse transcription polymerase chain reaction (RT-PCR) testing, and chest computed tomography (CT) scans are also used to determine the disease's phases. This is all because of the fact that RT-PCR method caries with itself a number of downsides comprising of being immovable, expensive, and laborious. RT-PCR has not well proven to be capable of detection on the very early infection stages. Nanomaterial-based diagnostics, together with traditional clinical procedures, have a lot of promise against COVID-19. It is worthy of attention that nanotechnology has the mainstay capacity for purposes of developing even more modern stratagems fighting COVID-19 by means of focusing on state-of-the-art diagnostics. What we have centered on in this review, is bringing out even more efficient detection techniques whereby nanobiosensors are employed so that we might obstruct any further development and spreading of SARS-CoV-2.
Collapse
Affiliation(s)
- Mohammad Mohammadi
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Zahra Asvar
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Seyyed Pooria Solhjoo
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mohammad Sarikhanikhorrami
- Department of Medical Laboratory Sciences, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Hassan Ghader Abadi
- Department of Biological Sciences, Faculty of Science, Islamic Azad University of Kazerun, Kazerun, Iran
| | - Shirin Ghazizadeh
- Department of Biological Sciences, Faculty of Science, Islamic Azad University of Jahrom, Jahrom, Iran
| | - Hassan Mahmoodi
- Department of Biochemistry, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Niloofar Karbalaee Habibolah
- Department of Genetics, Reproductive Biomedicine Research Center, Royan Institute for Reproductive Biomedicine, ACECR, Tehran, Iran
| | - Omar Moradi
- Department of Electrical Engineering, Sanandaj Branch, Islamic Azad University, Sanandaj, Iran
| | - Prashant Kesharwani
- Department of Pharmaceutics, School of Pharmaceutical Education and Research, Jamia Hamdard, New Delhi 110062, India
| | - Ali Mohammad Amani
- Department of Medical Nanotechnology, School of Advanced Medical Sciences and Technologies, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Amirhossein Sahebkar
- Center for Global Health Research, Saveetha Medical College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India; Biotechnology Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Applied Biomedical Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
| |
Collapse
|
3
|
Sun S, Zhao Y, Hao Y, Xue P, Guo X, Zhang W, Zhang C, Zhang Q, Zhou W, Ong HC, Yu X, Li Z, Li J, Yao J. Rapid, sensitive and multiplexed detection of SARS-CoV-2 viral nucleic acids enabled by phase-based surface plasmon resonance of metallic gratings. BIOMEDICAL OPTICS EXPRESS 2024; 15:5215-5226. [PMID: 39296394 PMCID: PMC11407254 DOI: 10.1364/boe.535051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 08/05/2024] [Accepted: 08/06/2024] [Indexed: 09/21/2024]
Abstract
A rapid, sensitive and easy-to-implement approach is proposed for the detection of pathogenic nucleic acids based on phase-based plasmonic spectroscopy of metallic gratings. The plasmonic sensors were fabricated using interference lithography and functionalized with single-stranded DNA probes to specific target SARS-CoV-2. The biosensor achieved the detection of 40 fM viral nucleic acids within 5 min; furthermore, a detection capability of 1 aM (0.6 copies/µL) was acquired when combining with the recombinase polymerase amplification. Additionally, the multiplexed sensing system was demonstrated to simultaneously detect three genomic sequences on a single sensor chip, thereby enhancing diagnostic accuracy and enabling high-throughput detection.
Collapse
Affiliation(s)
- Shuai Sun
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Yuanyuan Zhao
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Yuxuan Hao
- Interface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Pan Xue
- Interface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Xiaoyang Guo
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Wei Zhang
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Chunxiang Zhang
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Qiongdi Zhang
- Interface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Wenhua Zhou
- Interface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Hock Chun Ong
- Department of Physics, The Chinese University of Hong Kong, Shatin, Hong Kong SAR, China
| | - Xuefeng Yu
- Interface Materials Center, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Zeren Li
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Jia Li
- Center for Intense Laser Application Technology, College of Engineering Physics, Shenzhen Technology University, Shenzhen 518118, China
| | - Jianquan Yao
- Key Laboratory of Opto-Electronics Information Technology (Tianjin University), Ministry of Education, School of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China
| |
Collapse
|
4
|
Sloan-Dennison S, Wallace GQ, Hassanain WA, Laing S, Faulds K, Graham D. Advancing SERS as a quantitative technique: challenges, considerations, and correlative approaches to aid validation. NANO CONVERGENCE 2024; 11:33. [PMID: 39154073 PMCID: PMC11330436 DOI: 10.1186/s40580-024-00443-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Accepted: 08/06/2024] [Indexed: 08/19/2024]
Abstract
Surface-enhanced Raman scattering (SERS) remains a significant area of research since it's discovery 50 years ago. The surface-based technique has been used in a wide variety of fields, most prominently in chemical detection, cellular imaging and medical diagnostics, offering high sensitivity and specificity when probing and quantifying a chosen analyte or monitoring nanoparticle uptake and accumulation. However, despite its promise, SERS is mostly confined to academic laboratories and is not recognised as a gold standard analytical technique. This is due to the variations that are observed in SERS measurements, mainly caused by poorly characterised SERS substrates, lack of universal calibration methods and uncorrelated results. To convince the wider scientific community that SERS should be a routinely used analytical technique, the field is now focusing on methods that will increase the reproducibility of the SERS signals and how to validate the results with more well-established techniques. This review explores the difficulties experienced by SERS users, the methods adopted to reduce variation and suggestions of best practices and strategies that should be adopted if one is to achieve absolute quantification.
Collapse
Affiliation(s)
- Sian Sloan-Dennison
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK
| | - Gregory Q Wallace
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK
| | - Waleed A Hassanain
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK
| | - Stacey Laing
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK
| | - Karen Faulds
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK
| | - Duncan Graham
- Department of Pure and Applied Chemistry, Technology and Innovation Centre, University of Strathclyde, 99 George Street, Glasgow, G1 1RD, UK.
| |
Collapse
|
5
|
Mcotshana ZKS, Thwala LN, Tlomatsane MHC, van Steen E, Mthunzi-Kufa P. Recent advances in the development of multiplexed nanophotonic biosensors. Photodiagnosis Photodyn Ther 2024; 48:104246. [PMID: 38866068 DOI: 10.1016/j.pdpdt.2024.104246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Revised: 05/24/2024] [Accepted: 06/10/2024] [Indexed: 06/14/2024]
Abstract
The field of nanophotonics has advanced and can be utilized as a method to detect different infectious diseases. The introduction of multiplex nanophotonic diagnostics has enabled the speedy and simultaneous detection of viral infections and specific biomarkers. The quick reaction times, high sensitivity, and specificity of multiplex nanophotonic diagnostics enable real-time identification of viruses without the need for nucleic acid amplification. This review presents an overview of nanophotonic tools used to identify diseases and particular biomarkers. The paper also examines possible research areas for the development of unique, cutting-edge multiplex nanophotonic diagnostics capable of concurrently detecting various diseases or biomarkers/biomolecules. Furthermore, it discusses barriers to further advancement and offers insight into anticipated trends.
Collapse
Affiliation(s)
- Z K S Mcotshana
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa; Department of Chemical Engineering, University of Cape Town, South Ln, Rondebosch, Cape Town 7700, South Africa.
| | - L N Thwala
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa
| | - M H C Tlomatsane
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa; Department of Medical Virology, Department of Pathology, Faculty of Health Sciences, University of Cape Town, South Ln, Rondebosch, Cape Town 7700, South Africa
| | - E van Steen
- Department of Chemical Engineering, University of Cape Town, South Ln, Rondebosch, Cape Town 7700, South Africa
| | - P Mthunzi-Kufa
- National Laser Centre, Council for Scientific and Industrial Research, P.O. Box 395, Pretoria 0001, South Africa; College of Agriculture, Engineering and Science, School of Chemistry and Physics, University of Kwa-Zulu Natal, University Road, Westville, Durban 3630, South Africa
| |
Collapse
|
6
|
Lin M, Wang C, Fan R, Zhao X, Yu L, Lu M, Peng W. Multi-channel prismatic localized surface plasmon resonance biosensor for real-time competitive assay multiple COVID-19 characteristic miRNAs. Talanta 2024; 275:126142. [PMID: 38669961 DOI: 10.1016/j.talanta.2024.126142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 04/15/2024] [Accepted: 04/20/2024] [Indexed: 04/28/2024]
Abstract
A multi-channel prismatic localized surface plasmon resonance (LSPR) biosensor was developed for quantitative and real-time detection of multiple COVID-19 characteristic miRNAs. The well-dispersed and dense gold nanoparticles (AuNPs) arrays for LSPR biosensing were fabricated through a nano-thickness diblock copolymer template (BCPT). Both theoretical and experimental analyses were conducted to investigate the effects of particle size, interparticle spacing, and surface coverage on LSPR sensing spectrum and intensity sensitivity of varied AuNPs sizes. A competitive assay strategy was proposed and used for non-amplification miRNA detection with a low limit detection of 3.41 nM, while a four-channel prismatic LSPR system enables parallel detection of multiple miRNAs. Furthermore, this sensing strategy can effectively and specifically identify target miRNA, distinguish mismatched miRNA and interfering miRNA, and exhibit low non-specific adsorption. This BCPT-based LSPR biosensor demonstrates the practicality and potential of a multi-channel, adaptable, and integrated prismatic sensor in medical testing and diagnostic applications.
Collapse
Affiliation(s)
- Ming Lin
- Affiliated Cancer Hospital, Dalian University of Technology, Shenyang, 110042, China; School of Physics, Dalian University of Technology, Dalian, 116024, China
| | - Chen Wang
- School of Physics, Dalian University of Technology, Dalian, 116024, China
| | - Ruizhi Fan
- School of Physics, Dalian University of Technology, Dalian, 116024, China
| | - Xinya Zhao
- School of Physics, Dalian University of Technology, Dalian, 116024, China
| | - Li Yu
- School of Physics, Dalian University of Technology, Dalian, 116024, China
| | - Mengdi Lu
- Affiliated Cancer Hospital, Dalian University of Technology, Shenyang, 110042, China; School of Physics, Dalian University of Technology, Dalian, 116024, China.
| | - Wei Peng
- School of Physics, Dalian University of Technology, Dalian, 116024, China
| |
Collapse
|
7
|
Tene T, Bellucci S, Arias Arias F, Carrera Almendariz LS, Flores Huilcapi AG, Vacacela Gomez C. Role of Graphene in Surface Plasmon Resonance-Based Biosensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:4670. [PMID: 39066066 PMCID: PMC11280817 DOI: 10.3390/s24144670] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 07/08/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
This work explores the transformative role of graphene in enhancing the performance of surface plasmon resonance (SPR)-based biosensors. The motivation for this review stems from the growing interest in the unique properties of graphene, such as high surface area, excellent electrical conductivity, and versatile functionalization capabilities, which offer significant potential to improve the sensitivity, specificity, and stability of SPR biosensors. This review systematically analyzes studies published between 2010 and 2023, covering key metrics of biosensor performance. The findings reveal that the integration of graphene consistently enhances sensitivity. Specificity, although less frequently reported numerically, showed promising results, with high specificity achieved at sub-nanomolar concentrations. Stability enhancements are also significant, attributed to the protective properties of graphene and improved biomolecule adsorption. Future research should focus on mechanistic insights, optimization of integration techniques, practical application testing, scalable fabrication methods, and comprehensive comparative studies. Our findings provide a foundation for future research, aiming to further optimize and harness the unique physical properties of graphene to meet the demands of sensitive, specific, stable, and rapid biosensing in various practical applications.
Collapse
Affiliation(s)
- Talia Tene
- Department of Chemistry, Universidad Técnica Particular de Loja, Loja 110160, Ecuador;
| | - Stefano Bellucci
- INFN-Laboratori Nazionali di Frascati, Via E. Fermi 54, I-00044 Frascati, Italy
| | - Fabian Arias Arias
- Facultad de Ciencias, Escuela Superior Politécnica de Chimborazo (ESPOCH), Riobamba 060155, Ecuador
- Dipartimento di Chimica e Tecnologie Chimiche, University of Calabria, Via P. Bucci, Cubo 15D, I-87036 Rende, Italy
| | | | - Ana Gabriela Flores Huilcapi
- Facultad de Ciencia e Ingeniería en Alimentos y Biotecnología, Universidad Técnica de Ambato, Ambato 180104, Ecuador
| | | |
Collapse
|
8
|
Yadav PK, Kumar A, Upadhyay S, Kumar A, Srivastava A, Srivastava M, Srivastava SK. 2D material-based surface plasmon resonance biosensors for applications in different domains: an insight. Mikrochim Acta 2024; 191:373. [PMID: 38842697 DOI: 10.1007/s00604-024-06442-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 05/16/2024] [Indexed: 06/07/2024]
Abstract
The design of surface plasmon resonance (SPR) sensors has been greatly enhanced in recent years by the advancements in the production and integration of nanostructures, leading to more compact and efficient devices. There have been reports of novel SPR sensors having distinct nanostructures, either as signal amplification tags like gold nanoparticles (AuNPs) or as sensing substrate-like two-dimensional (2D) materials including graphene, transition metal dichalcogenides (TMDCs), MXene, black phosphorus (BP), metal-organic frameworks (MOFs), and antimonene. Such 2D-based SPR biosensors offer advantages over conventional sensors due to significant increases in their sensitivity with a good figure of merit and limit of detection (LOD). Due to their atomically thin structure, improved sensitivity, and sophisticated functionalization capabilities, 2D materials can open up new possibilities in the field of healthcare, particularly in point-of-care diagnostics, environmental and food monitoring, homeland security protection, clinical diagnosis and treatment, and flexible or transient bioelectronics. The present study articulates an in-depth analysis of the most recent developments in 2D material-based SPR sensor technology. Moreover, in-depth research of 2D materials, their integration with optoelectronic technology for a new sensing platform, and the predicted and experimental outcomes of various excitation approaches are highlighted, along with the principles of SPR biosensors. Furthermore, the review projects the potential prospects and future trends of these emerging materials-based SPR biosensors to advance in clinical diagnosis, healthcare biochemical, and biological applications.
Collapse
Affiliation(s)
- Prateek Kumar Yadav
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Awadhesh Kumar
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Satyam Upadhyay
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Anil Kumar
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Amit Srivastava
- Department of Physics TDPG College, VBS Purvanchal University, Jaunpur, 222001, India
| | - Monika Srivastava
- School of Materials Science and Technology, Indian Institute of Technology (Banaras Hindu University), Varanasi, India
| | - S K Srivastava
- Department of Physics, Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| |
Collapse
|
9
|
Li X, Sun R, Pan J, Shi Z, An Z, Dai C, Lv J, Liu G, Liang H, Liu J, Lu Y, Zhang F, Liu Q. Rapid and on-site wireless immunoassay of respiratory virus aerosols via hydrogel-modulated resonators. Nat Commun 2024; 15:4035. [PMID: 38740742 PMCID: PMC11091083 DOI: 10.1038/s41467-024-48294-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 04/26/2024] [Indexed: 05/16/2024] Open
Abstract
Rapid and accurate detection of respiratory virus aerosols is highlighted for virus surveillance and infection control. Here, we report a wireless immunoassay technology for fast (within 10 min), on-site (wireless and battery-free), and sensitive (limit of detection down to fg/L) detection of virus antigens in aerosols. The wireless immunoassay leverages the immuno-responsive hydrogel-modulated radio frequency resonant sensor to capture and amplify the recognition of virus antigen, and flexible readout network to transduce the immuno bindings into electrical signals. The wireless immunoassay achieves simultaneous detection of respiratory viruses such as severe acute respiratory syndrome coronavirus 2, influenza A H1N1 virus, and respiratory syncytial virus for community infection surveillance. Direct detection of unpretreated clinical samples further demonstrates high accuracy for diagnosis of respiratory virus infection. This work provides a sensitive and accurate immunoassay technology for on-site virus detection and disease diagnosis compatible with wearable integration.
Collapse
Affiliation(s)
- Xin Li
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
- Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University-Taizhou, Taizhou, 318000, China
| | - Rujing Sun
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
- Guangxi Key Laboratory of AIDS Prevention and Treatment, School of Public Health, Biosafety III Laboratory, Life Science Institute, Guangxi Medical University, Nanning, 530021, Guangxi, China
| | - Jingying Pan
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
- School of Medicine, Zhejiang University, Hangzhou, 310027, China
| | - Zhenghan Shi
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Zijian An
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Chaobo Dai
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Jingjiang Lv
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Guang Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Hao Liang
- Guangxi Key Laboratory of AIDS Prevention and Treatment, School of Public Health, Biosafety III Laboratory, Life Science Institute, Guangxi Medical University, Nanning, 530021, Guangxi, China
| | - Jun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
- Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University-Taizhou, Taizhou, 318000, China
| | - Yanli Lu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
- Intelligent Perception Research Institute, Zhejiang Lab, Hangzhou, 311100, China
| | - Fenni Zhang
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China
| | - Qingjun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China.
- Taizhou Key Laboratory of Medical Devices and Advanced Materials, Research Institute of Zhejiang University-Taizhou, Taizhou, 318000, China.
| |
Collapse
|
10
|
Agarwal S, Srivastava R, Kumar S, Prajapati YK. COVID-19 Detection Using Contemporary Biosensors and Machine Learning Approach: A Review. IEEE Trans Nanobioscience 2024; 23:291-299. [PMID: 38090858 DOI: 10.1109/tnb.2023.3342126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2024]
Abstract
The current global pandemic not only claims countless human lives but also rocks the economies of every country on the planet. This fact needs the development of novel, productive, and efficient techniques to detect the SARS-CoV-2 virus. This review article discusses the current state of SARS-CoV-2 virus detection methods such as electrochemical, fluorescent, and electronic, etc., as well as the potential of optical sensors with a wide range of novel approaches and models. This review provides a comprehensive comparison of various detection methods by comparing the various techniques in depth. In addition, there is a brief discussion of the futuristic approach combining optical sensors with machine learning algorithms. It is believed that this study would prove to be critical for the scientific community to explore solutions for detecting viruses with improved functionality.
Collapse
|
11
|
Lei Y, Xu D. Rapid Nucleic Acid Diagnostic Technology for Pandemic Diseases. Molecules 2024; 29:1527. [PMID: 38611806 PMCID: PMC11013254 DOI: 10.3390/molecules29071527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 03/17/2024] [Accepted: 03/19/2024] [Indexed: 04/14/2024] Open
Abstract
The recent global pandemic of coronavirus disease 2019 (COVID-19) has enormously promoted the development of diagnostic technology. To control the spread of pandemic diseases and achieve rapid screening of the population, ensuring that patients receive timely treatment, rapid diagnosis has become the top priority in the development of clinical technology. This review article aims to summarize the current rapid nucleic acid diagnostic technologies applied to pandemic disease diagnosis, from rapid extraction and rapid amplification to rapid detection. We also discuss future prospects in the development of rapid nucleic acid diagnostic technologies.
Collapse
Affiliation(s)
- Yu Lei
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology (NCNST), Chinese Academy of Sciences (CAS), Beijing 100190, China;
- University of Chinese Academy of Sciences (UCAS), Beijing 100049, China
| | - Dawei Xu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, National Center for Nanoscience and Technology (NCNST), Chinese Academy of Sciences (CAS), Beijing 100190, China;
| |
Collapse
|
12
|
Feng R, Fu S, Liu H, Wang Y, Liu S, Wang K, Chen B, Zhang X, Hu L, Chen Q, Cai T, Han X, Wang C. Single-Atom Site SERS Chip for Rapid, Ultrasensitive, and Reproducible Direct-Monitoring of RNA Binding. Adv Healthc Mater 2024; 13:e2301146. [PMID: 38176000 DOI: 10.1002/adhm.202301146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 12/11/2023] [Indexed: 01/06/2024]
Abstract
Ribonucleic acids (RNA) play active roles within cells or viruses by catalyzing biological reactions, controlling gene expression, and communicating responses to cellular signals. Rapid monitoring RNA variation has become extremely important for appropriate clinical decisions and frontier biological research. However, the most widely used method for RNA detection, nucleic acid amplification, is restricted by a mandatory temperature cycling period of ≈1 h required to reach target detection criteria. Herein, a direct detection approach via single-atom site integrated surface-enhanced Raman scattering (SERS) monitoring nucleic acid pairing reaction, can be completed within 3 min and reaches high sensitivity and extreme reproducibility for COVID-19 and two other influenza viruses' detection. The mechanism is that a single-atom site on SERS chip, enabled by positioning a single-atom oxide coordinated with a specific complementary RNA probe on chip nanostructure hotspots, can effectively bind target RNA analytes to enrich them at designed sites so that the binding reaction can be detected through Raman signal variation. This ultrafast, sensitive, and reproducible single-atom site SERS chip approach paves the route for an alternative technique of immediate RNA detection. Moreover, single-atom site SERS is a novel surface enrichment strategy for SERS active sites for other analytes at ultralow concentrations.
Collapse
Affiliation(s)
- Ran Feng
- Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Province, Ningbo No. 2 Hospital, Ningbo, 315012, China
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
| | - Shaohua Fu
- Key Laboratory of Luminescence and Optical Information, Ministry of Education, Institute of Optoelectronic Technology, Beijing Jiaotong University, Beijing, 100044, China
- Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190, China
| | | | - Ying Wang
- State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, P. R. China
| | - Simiao Liu
- Thorgene Co., Ltd, Beijing, 100176, China
| | - Kaiwen Wang
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
| | - Binbin Chen
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
| | - Xiaoxian Zhang
- Key Laboratory of Luminescence and Optical Information, Ministry of Education, Institute of Optoelectronic Technology, Beijing Jiaotong University, Beijing, 100044, China
| | - Liming Hu
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
| | - Qian Chen
- Thorgene Co., Ltd, Beijing, 100176, China
| | - Ting Cai
- Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Province, Ningbo No. 2 Hospital, Ningbo, 315012, China
| | - Xiaodong Han
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
| | - Cong Wang
- Ningbo Institute of Life and Health Industry, University of Chinese Academy of Sciences, Key Laboratory of Diagnosis and Treatment of Digestive System Tumors of Zhejiang Province, Ningbo No. 2 Hospital, Ningbo, 315012, China
- Beijing Key Laboratory of Microstructure and Properties of Solids, Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, 100124, China
- Thorgene Co., Ltd, Beijing, 100176, China
| |
Collapse
|
13
|
Kim YJ, Min J. Advances in nanobiosensors during the COVID-19 pandemic and future perspectives for the post-COVID era. NANO CONVERGENCE 2024; 11:3. [PMID: 38206526 PMCID: PMC10784265 DOI: 10.1186/s40580-023-00410-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Accepted: 12/07/2023] [Indexed: 01/12/2024]
Abstract
The unprecedented threat of the highly contagious virus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes exponentially increased infections of coronavirus disease 2019 (COVID-19), highlights the weak spots of the current diagnostic toolbox. In the midst of catastrophe, nanobiosensors offer a new opportunity as an alternative tool to fill a gap among molecular tests, rapid antigen tests, and serological tests. Nanobiosensors surpass the potential of antigen tests because of their enhanced sensitivity, thus enabling us to see antigens as stable and easy-to-access targets. During the first three years of the COVID-19 pandemic, a substantial number of studies have reported nanobiosensors for the detection of SARS-CoV-2 antigens. The number of articles on nanobiosensors and SARS-CoV-2 exceeds the amount of nanobiosensor research on detecting previous infectious diseases, from influenza to SARS-CoV and MERS-CoV. This unprecedented publishing pace also implies the significance of SARS-CoV-2 and the present pandemic. In this review, 158 studies reporting nanobiosensors for detecting SARS-CoV-2 antigens are collected to discuss the current challenges of nanobiosensors using the criteria of point-of-care (POC) diagnostics along with COVID-specific issues. These advances and lessons during the pandemic pave the way for preparing for the post-COVID era and potential upcoming infectious diseases.
Collapse
Affiliation(s)
- Young Jun Kim
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea
| | - Junhong Min
- School of Integrative Engineering, Chung-Ang University, Heukseok-Dong, Dongjak-Gu, Seoul, 06974, Republic of Korea.
| |
Collapse
|
14
|
Sayin S, Zhou Y, Wang S, Acosta Rodriguez A, Zaghloul M. Development of Liquid-Phase Plasmonic Sensor Platforms for Prospective Biomedical Applications. SENSORS (BASEL, SWITZERLAND) 2023; 24:186. [PMID: 38203048 PMCID: PMC10781335 DOI: 10.3390/s24010186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/15/2023] [Accepted: 12/25/2023] [Indexed: 01/12/2024]
Abstract
Localized Surface Plasmon Resonance (LSPR) is an optical method for detecting changes in refractive index by the interaction between incident light and delocalized electrons within specific metal thin films' localized "hot spots". LSPR-based sensors possess advantages, including their compact size, enhanced sensitivity, cost-effectiveness, and suitability for point-of-care applications. This research focuses on the development of LSPR-based nanohole arrays (NHAs) as a platform for monitoring probe/target binding events in real time without labeling, for low-level biomolecular target detection in biomedical diagnostics. To achieve this objective, this study involves creating a liquid-phase setup for capturing target molecules. Finite-difference time-domain simulations revealed that a 75 nm thickness of gold (Au) is ideal for NHA structures, which were visually examined using scanning electron microscopy. To illustrate the functionality of the liquid-phase sensor, a PDMS microfluidic channel was fabricated using a 3D-printed mold with a glass slide base and a top glass cover slip, enabling reflectance-mode measurements from each of four device sectors. This study shows the design, fabrication, and assessment of NHA-based LSPR sensor platforms within a PDMS microfluidic channel, confirming the sensor's functionality and reproducibility in a liquid-phase environment.
Collapse
Affiliation(s)
- Sezin Sayin
- Department of Electrical and Computer Engineering, School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| | - You Zhou
- Department of Electrical and Computer Engineering, School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| | - Sheng Wang
- Department of Biomedical Engineering, School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| | | | - Mona Zaghloul
- Department of Electrical and Computer Engineering, School of Engineering and Applied Science, The George Washington University, Washington, DC 20052, USA
| |
Collapse
|
15
|
Mustaffa SN, Md Yatim N, Abdul Rashid AR, Md Yatim N, Pithaih V, Sha'ari NS, Muhammad AR, Abdul Rahman A, Jamil NA, Menon PS. Visible and angular interrogation of Kretschmann-based SPR using hybrid Au-ZnO optical sensor for hyperuricemia detection. Heliyon 2023; 9:e22926. [PMID: 38125452 PMCID: PMC10731088 DOI: 10.1016/j.heliyon.2023.e22926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 11/21/2023] [Accepted: 11/22/2023] [Indexed: 12/23/2023] Open
Abstract
Uric acid is a waste product of the human body where high levels of it or hyperuricemia can lead to gout, kidney disease and other health issues. In this paper, Finite Difference Time Doman (FDTD) simulation method was used to develop a plasmonic optical sensor to detect uric acid with molarity ranging from 0 to 3.0 mM. A hybrid layer of gold-zinc oxide (Au-ZnO) was used in this Kretschmann-based Surface Plasmon Resonance (K-SPR) technique with angular interrogation at 670 nm and 785 nm visible optical wavelengths. The purpose of this study is to observe the ability of the hybrid material as a sensing performance enhancer for differentiating between healthy and unhealthy uric acid levels based on the refractive index values from previous study. Upon exposure to 670 nm wavelength, the average sensitivity of this sensor was found to be 0.028°/mM with a linearity of 98.67 % and Q-factor value of 0.0053 mM - 1 . While at 785 nm, the average sensitivity is equal to 0.0193°/mM with slightly lower linearity at 94.46 % and Q-factor value of 0.0076 mM - 1 . The results have proven the ability of hybrid material Au-ZnO as a sensing performance enhancer for detecting uric acid when compared with bare Au and can be further explored in experimental work.
Collapse
Affiliation(s)
- Siti Nasuha Mustaffa
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Nadhrah Md Yatim
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Affa Rozana Abdul Rashid
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Nadrah Md Yatim
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Vatsala Pithaih
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Nur Shahirah Sha'ari
- Faculty of Science and Technology, Universiti Sains Islam Malaysia (USIM), Bandar Baharu Nilai, 71800, Nilai, Negeri Sembilan, Malaysia
| | - Ahmad Razif Muhammad
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - Azaham Abdul Rahman
- Kulim Hi-Tech Pte Ltd, No.1, Jalan Bukit Hijau 26/24, Section 26, 40400, Shah Alam, Selangor, Malaysia
| | - Nur Akmar Jamil
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| | - P. Susthitha Menon
- Institute of Microengineering and Nanoelectronics (IMEN), Universiti Kebangsaan Malaysia, 43600, UKM Bangi, Selangor, Malaysia
| |
Collapse
|
16
|
Abrha FH, Wondimu TH, Kahsay MH, Fufa Bakare F, Andoshe DM, Kim JY. Graphene-based biosensors for detecting coronavirus: a brief review. NANOSCALE 2023; 15:18184-18197. [PMID: 37927083 DOI: 10.1039/d3nr04583h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2023]
Abstract
The coronavirus (SARS-CoV-2) disease has affected the globe with 770 437 327 confirmed cases, including about 6 956 900 deaths, according to the World Health Organization (WHO) as of September 2023. Hence, it is imperative to develop diagnostic technologies, such as a rapid cost-effective SARS-CoV-2 detection method. A typical biosensor enables biomolecule detection with an appropriate transducer by generating a measurable signal from the sample. Graphene can be employed as a component for ultrasensitive and selective biosensors based on its physical, optical, and electrochemical properties. Herein, we briefly review graphene-based electrochemical, field-effect transistor (FET), and surface plasmon biosensors for detecting the SARS-CoV-2 target. In addition, details on the surface modification, immobilization, sensitivity and limit of detection (LOD) of all three sensors with regard to SARS-CoV-2 were reported. Finally, the point-of-care (POC) detection of SARS-CoV-2 using a portable smartphone and a wearable watch is a current topic of interest.
Collapse
Affiliation(s)
- Filimon Hadish Abrha
- Department of Chemistry, College of Natural and Computational Sciences, Aksum University, Aksum 1010, Ethiopia
- Department of Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia.
| | - Tadele Hunde Wondimu
- Department of Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia.
- Center of Advanced Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia
| | - Mebrahtu Hagos Kahsay
- Department of Applied Chemistry, College of Natural and Computational Sciences, Mekelle University, Mekelle 231, Ethiopia
- Department of Applied Chemistry, Adama Science and Technology University, Adama 1888, Ethiopia
| | - Fetene Fufa Bakare
- Department of Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia.
- Center of Advanced Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia
| | - Dinsefa Mensur Andoshe
- Department of Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia.
| | - Jung Yong Kim
- Department of Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia.
- Center of Advanced Materials Science and Engineering, Adama Science and Technology University, Adama 1888, Ethiopia
| |
Collapse
|
17
|
Uzunoglu A, Gunes Altuntas E, Huseyin Ipekci H, Ozoglu O. Two-Dimensional (2D) materials in the detection of SARS-CoV-2. Microchem J 2023; 193:108970. [PMID: 37342763 PMCID: PMC10265934 DOI: 10.1016/j.microc.2023.108970] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 06/10/2023] [Accepted: 06/10/2023] [Indexed: 06/23/2023]
Abstract
The SARS-CoV-2 pandemic has resulted in a devastating effect on human health in the last three years. While tremendous effort has been devoted to the development of effective treatment and vaccines against SARS-CoV-2 and controlling the spread of it, collective health challenges have been encountered along with the concurrent serious economic impacts. Since the beginning of the pandemic, various detection methods like PCR-based methods, isothermal nucleic acid amplification-based (INAA) methods, serological methods or antibody tests, and evaluation of X-ray chest results have been exploited to diagnose SARS-CoV-2. PCR-based detection methods in these are considered gold standards in the current stage despite their drawbacks, including being high-cost and time-consuming procedures. Furthermore, the results obtained from the PCR tests are susceptible to sample collection methods and time. When the sample is not collected properly, obtaining a false result may be likely. The use of specialized lab equipment and the need for trained people for the experiments pose additional challenges in PCR-based testing methods. Also, similar problems are observed in other molecular and serological methods. Therefore, biosensor technologies are becoming advantageous with their quick response, high specificity and precision, and low-cost characteristics for SARS-CoV-2 detection. In this paper, we critically review the advances in the development of sensors for the detection of SARS-CoV-2 using two-dimensional (2D) materials. Since 2D materials including graphene and graphene-related materials, transition metal carbides, carbonitrides, and nitrides (MXenes), and transition metal dichalcogenides (TMDs) play key roles in the development of novel and high-performance electrochemical (bio)sensors, this review pushes the sensor technologies against SARS-CoV-2 detection forward and highlights the current trends. First, the basics of SARS-CoV-2 detection are described. Then the structure and the physicochemical properties of the 2D materials are explained, which is followed by the development of SARS-CoV-2 sensors by exploiting the exceptional properties of the 2D materials. This critical review covers most of the published papers in detail from the beginning of the outbreak.
Collapse
Affiliation(s)
- Aytekin Uzunoglu
- Faculty of Engineering, Metallurgical & Materials Engineering, Necmettin Erbakan University, Konya 42090, Turkey
| | - Evrim Gunes Altuntas
- Ankara University, Biotechnology Institute, Gumusdere Campus, 06135, Ankara, Turkey
| | - Hasan Huseyin Ipekci
- Faculty of Engineering, Metallurgical & Materials Engineering, Necmettin Erbakan University, Konya 42090, Turkey
| | - Ozum Ozoglu
- Department of Food Engineering, Faculty of Agriculture, Bursa Uludag University, 16059 Bursa, Turkey
| |
Collapse
|
18
|
Wang H, Wang T, Yuan X, Wang Y, Yue X, Wang L, Zhang J, Wang J. Plasmonic Nanostructure Biosensors: A Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:8156. [PMID: 37836985 PMCID: PMC10575025 DOI: 10.3390/s23198156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/20/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023]
Abstract
Plasmonic nanostructure biosensors based on metal are a powerful tool in the biosensing field. Surface plasmon resonance (SPR) can be classified into localized surface plasmon resonance (LSPR) and propagating surface plasmon polariton (PSPP), based on the transmission mode. Initially, the physical principles of LSPR and PSPP are elaborated. In what follows, the recent development of the biosensors related to SPR principle is summarized. For clarity, they are categorized into three groups according to the sensing principle: (i) inherent resonance-based biosensors, which are sensitive to the refractive index changes of the surroundings; (ii) plasmon nanoruler biosensors in which the distances of the nanostructure can be changed by biomolecules at the nanoscale; and (iii) surface-enhanced Raman scattering biosensors in which the nanostructure serves as an amplifier for Raman scattering signals. Moreover, the advanced application of single-molecule detection is discussed in terms of metal nanoparticle and nanopore structures. The review concludes by providing perspectives on the future development of plasmonic nanostructure biosensors.
Collapse
Affiliation(s)
- Huimin Wang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Tao Wang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Xuyang Yuan
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Yuandong Wang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Xinzhao Yue
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Lu Wang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Jinyan Zhang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| | - Jian Wang
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China; (H.W.); (X.Y.); (Y.W.); (X.Y.); (L.W.); (J.Z.)
- Optics Valley Laboratory, Wuhan 430074, China
| |
Collapse
|
19
|
Yadav S, Parihar A, Sadique MA, Ranjan P, Kumar N, Singhal A, Khan R. Emerging Point-of-Care Optical Biosensing Technologies for Diagnostics of Microbial Infections. ACS APPLIED OPTICAL MATERIALS 2023; 1:1245-1262. [DOI: 10.1021/acsaom.3c00129] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/11/2025]
Affiliation(s)
- Shalu Yadav
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Arpana Parihar
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
| | - Mohd Abubakar Sadique
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Pushpesh Ranjan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Neeraj Kumar
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Ayushi Singhal
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Raju Khan
- Industrial Waste Utilization, Nano and Biomaterials, CSIR─Advanced Materials and Processes Research Institute (AMPRI), Hoshangabad Road, Bhopal 462026, Madhya Pradesh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| |
Collapse
|
20
|
Kurt Z, Çimen D, Denizli A, Bereli N. Development of Optical-Based Molecularly Imprinted Nanosensors for Adenosine Detection. ACS OMEGA 2023; 8:18839-18850. [PMID: 37273602 PMCID: PMC10233842 DOI: 10.1021/acsomega.3c01028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 04/28/2023] [Indexed: 06/06/2023]
Abstract
Adenosine nucleoside is an important molecule in human physiology. The levels of adenosine nucleoside in urine and plasma are directly or indirectly related to diseases such as neurodegenerative diseases and cancer. In the present study, adenosine-imprinted and non-imprinted poly(2-hydroxyethyl methacrylate-methacrylic acid) (poly(HEMA-MAA)) surface plasmon resonance (SPR) nanosensors were prepared for the determination of adenosine nucleoside. First, MAA/adenosine pre-polymerization complexes were prepared at different molar ratios using adenosine as a template molecule and methacrylic acid (MAA) as a monomer, and SPR nanosensor surfaces were optimized by determining the highest imprinting factor of the chip surfaces. The surfaces of adenosine-imprinted and non-imprinted SPR nanosensors were characterized by using atomic force microscopy, ellipsometry, and contact angle measurements. Kinetic analyses were made with different concentrations in the range of 0.5-400.0 nM for the detection range with a pH 7.4 phosphate buffer solution. The limit of detection in adenosine aqueous solutions, artificial plasma, and artificial urine was determined to be 0.018, 0.015, and 0.013 nM, respectively. In the selectivity analysis of the developed nanosensors, the selectivity of adenosine SPR nanosensors in solutions at different concentrations was determined by using guanosine and cytidine nucleosides. The relative selectivity coefficients of adenosine-imprinted SPR nanosensors for adenosine/cytidine and adenosine/guanosine are 3.836 and 3.427, respectively. Since adenosine-imprinted SPR nanosensors are intended to be used in medical analysis and research, adenosine analysis has also been studied in artificial urine and artificial plasma samples.
Collapse
Affiliation(s)
- Zehra
Tuğçe Kurt
- Bioengineering
Division, Hacettepe University, Ankara 06230, Turkey
| | - Duygu Çimen
- Department
of Chemistry, Hacettepe University, Ankara 06800, Turkey
| | - Adil Denizli
- Department
of Chemistry, Hacettepe University, Ankara 06800, Turkey
| | - Nilay Bereli
- Department
of Chemistry, Hacettepe University, Ankara 06800, Turkey
| |
Collapse
|
21
|
Fan L, Du B, Pei F, Hu W, Feng S, Liu B, Tong Z, Tan W, Mu X. A Novel SPR Immunosensor Based on Dual Signal Amplification Strategy for Detection of SARS-CoV-2 Nucleocapsid Protein. BIOSENSORS 2023; 13:bios13050549. [PMID: 37232910 DOI: 10.3390/bios13050549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/09/2023] [Accepted: 05/12/2023] [Indexed: 05/27/2023]
Abstract
Since the global outbreak of coronavirus disease 2019 (COVID-19), it has spread rapidly around the world. The nucleocapsid (N) protein is one of the most abundant SARS-CoV-2 proteins. Therefore, a sensitive and effective detection method for SARS-CoV-2 N protein is the focus of research. Here, we developed a surface plasmon resonance (SPR) biosensor based on the dual signal-amplification strategy of Au@Ag@Au nanoparticles (NPs) and graphene oxide (GO). Additionally, a sandwich immunoassay was utilized to sensitively and efficiently detect SARS-CoV-2 N protein. On the one hand, Au@Ag@Au NPs have a high refractive index and the capability to electromagnetically couple with the plasma waves propagating on the surface of gold film, which are harnessed for amplifying the SPR response signal. On the other hand, GO, which has the large specific surface area and the abundant oxygen-containing functional groups, could provide unique light absorption bands that can enhance plasmonic coupling to further amplify the SPR response signal. The proposed biosensor could efficiently detect SARS-CoV-2 N protein for 15 min and the detection limit for SARS-CoV-2 N protein was 0.083 ng/mL, with a linear range of 0.1 ng/mL~1000 ng/mL. This novel method can meet the analytical requirements of artificial saliva simulated samples, and the developed biosensor had a good anti-interference capability.
Collapse
Affiliation(s)
- Lirui Fan
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
- School of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
| | - Bin Du
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Fubin Pei
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Wei Hu
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Shasha Feng
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Bing Liu
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Zhaoyang Tong
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| | - Wenyuan Tan
- School of Chemical Engineering, Sichuan University of Science and Engineering, Zigong 643000, China
| | - Xihui Mu
- State Key Laboratory of NBC Protection for Civilian, Beijing 102205, China
| |
Collapse
|
22
|
Taya SA, Daher MG, Almawgani AHM, Hindi AT, Zyoud SH, Colak I. Detection of Virus SARS-CoV-2 Using a Surface Plasmon Resonance Device Based on BiFeO 3-Graphene Layers. PLASMONICS (NORWELL, MASS.) 2023; 18:1-8. [PMID: 37360049 PMCID: PMC10170057 DOI: 10.1007/s11468-023-01867-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2023] [Accepted: 04/24/2023] [Indexed: 06/28/2023]
Abstract
Coronavirus disease (COVID-19) pandemic outbreak is being investigated by severe respirational syndrome coronavirus-2 (SARS-CoV-2) as a global health issue. It is crucial to propose sensitive and rapid coronavirus detectors. Herein, we propose a biosensor based on surface plasmon resonance (SPRE) for the detection of SARS-CoV-2 virus. To achieve improved sensitivity, a BiFeO3 layer is inserted between a metal (Ag) thin film and a graphene layer in the proposed SPRE device so that it has the structure BK7 prism/ Ag/ BiFeO3/ graphene/ analyte. It has been demonstrated that a small variation in the refractive index of the analyte can cause a considerable shift in the resonance angle caused by the remarkable dielectric properties of the BiFeO3 layer, which include a high index of refraction and low loss. The proposed device has shown an extremely high sensitivity of 293 deg/RIU by optimizing the thicknesses of Ag, BiFeO3, and the number of graphene sheets. The proposed SPRE-based sensor is encouraging for use in various sectors of biosensing because of its high sensitivity.
Collapse
Affiliation(s)
- Sofyan A. Taya
- Physics Department, Islamic University of Gaza, P.O. Box 108, Gaza, Palestine
| | - Malek G. Daher
- Physics Department, Islamic University of Gaza, P.O. Box 108, Gaza, Palestine
| | - Abdulkarem H. M. Almawgani
- Electrical Engineering Department, College of Engineering, Najran University, Najran, Kingdom of Saudi Arabia
| | - Ayman Taher Hindi
- Electrical Engineering Department, College of Engineering, Najran University, Najran, Kingdom of Saudi Arabia
| | - Samer H. Zyoud
- Department of Mathematics and Sciences, Ajman University, Ajman, United Arab Emirates
| | - Ilhami Colak
- Department of Electrical and Electronics Engineering, Nisantasi University, Istanbul, Turkey
| |
Collapse
|
23
|
Hossain MM, Talukder MA. Graphene surface plasmon sensor for ultra-low-level SARS-CoV-2 detection. PLoS One 2023; 18:e0284812. [PMID: 37098037 PMCID: PMC10128942 DOI: 10.1371/journal.pone.0284812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Accepted: 04/08/2023] [Indexed: 04/26/2023] Open
Abstract
Precisely detecting the ultra-low-level severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is crucial. The detection mechanism must be sensitive, low-cost, portable, fast, and easy to operate to tackle coronavirus disease 19 (COVID-19). This work proposes a sensor exploiting graphene surface plasmon resonance to detect SARS-CoV-2. The graphene layer functionalized with angiotensin-converting enzyme 2 (ACE2) antibodies will help efficient adsorption of the SARS-CoV-2. In addition to the graphene layer, ultra-thin layers of novel two-dimensional materials tungsten disulfide (WS2), potassium niobate (KNbO3), and black phosphorus (BP) or blue phosphorus (BlueP) used in the proposed sensor will increase the light absorption to detect an ultra-low SARS-CoV-2 concentration. The analysis presented in this work shows that the proposed sensor will detect SARS-CoV-2 as small as ∼1 fM. The proposed sensor also offers a minimum sensitivity of 201 degrees/RIU, a figure-of-merit of 140 RIU-1, and enhanced binding kinetics of the SARS-CoV-2 to the sensor surface.
Collapse
Affiliation(s)
- Md. Mahbub Hossain
- Department of Electrical and Electronic Engineering, Bangladesh University of Engineering and Technology, Dhaka, Bangladesh
| | - Muhammad Anisuzzaman Talukder
- Department of Electrical and Electronic Engineering, Bangladesh University of Engineering and Technology, Dhaka, Bangladesh
| |
Collapse
|
24
|
Akib TBA, Mostufa S, Rana MM, Hossain MB, Islam MR. A performance comparison of heterostructure surface plasmon resonance biosensor for the diagnosis of novel coronavirus SARS-CoV-2. OPTICAL AND QUANTUM ELECTRONICS 2023; 55:448. [PMID: 37008732 PMCID: PMC10039361 DOI: 10.1007/s11082-023-04700-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 02/18/2023] [Indexed: 06/19/2023]
Abstract
This paper presents a performance comparison of heterostructure surface plasmon resonance (SPR) biosensors for the application of Novel Coronavirus SARS-CoV-2 diagnosis. The comparison is performed and compared with the existing literature based on the performance parameters in terms of several prisms such as BaF2, BK7, CaF2, CsF, SF6, and SiO2, several adhesion layers such as TiO2, Chromium, plasmonic metals such as Ag, Au, and two-dimensional (2D) transition metal dichalcogenides materials such as BP, Graphene, PtSe2 MoS2, MoSe2, WS2, WSe2. To study the performance of the heterostructure SPR sensor, the transfer matrix method is applied, and to analyses, the electric field intensity near the graphene-sensing layer contact, the finite-difference time-domain approach is utilized. Numerical results show that the heterostructure comprised of CaF2/TiO2/Ag/BP/Graphene/Sensing-layer has the best sensitivity and detection accuracy. The proposed sensor has an angle shift sensitivity of 390°/refractive index unit (RIU). Furthermore, the sensor achieved a detection accuracy of 0.464, a quality factor of 92.86/RIU, a figure of merit of 87.95, and a combined sensitive factor of 85.28. Furthermore, varied concentrations (0-1000 nM) of biomolecule binding interactions between ligands and analytes have been observed for the prospects of diagnosis of the SARS-CoV-2 virus. Results demonstrate that the proposed sensor is well suited for real-time and label-free detection particularly SARS-CoV-2 virus detection.
Collapse
Affiliation(s)
- Tarik Bin Abdul Akib
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi, 6204 Bangladesh
- Department of Electrical and Electronic Engineering, Bangladesh Army University of Engineering and Technology, Rajshahi, 6431 Bangladesh
| | - Shahriar Mostufa
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi, 6204 Bangladesh
| | - Md. Masud Rana
- Department of Electrical and Electronic Engineering, Rajshahi University of Engineering and Technology, Rajshahi, 6204 Bangladesh
| | - Md. Biplob Hossain
- Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522 Australia
- Department of Electrical and Electronic Engineering, Jashore University of Science and Technology, Jashore, 7408 Bangladesh
| | - Md. Rabiul Islam
- Faculty of Engineering and Information Sciences, University of Wollongong, Wollongong, NSW 2522 Australia
| |
Collapse
|
25
|
Guo Y, Su X, Wu K, Yong KT. Numerical Analysis of Three-dimensional Nanodisk Array-based Surface Plasmon Resonance Biosensors for SARS-CoV-2 Detection. PLASMONICS (NORWELL, MASS.) 2023; 18:769-779. [PMID: 36852386 PMCID: PMC9947906 DOI: 10.1007/s11468-023-01802-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
UNLABELLED With continuous mutations of SARS-CoV-2 virus, new highly contagious and fast-spreading variants have emerged, including Delta and Omicron. The popular label-free immunosensor based on surface plasmon resonance (SPR) technique can be used for real-time monitoring of the ligand-analyte or antibody-antigen interactions occurring on the sensor surface. In this work, an SPR-based biosensor combined with a nanodisk array was presented to enhance the sensitivity toward virus detection. The nanodisk arrays were employed to enhance the adsorption of molecules for better detection by increasing the SPR field. Four optimal sensing configurations of silver or gold nanodisks on gold thin films with different aspect ratios were achieved through systematic optimization of all parameters to yield the best sensor performance. The resonance angle can be modulated simply by the aspect ratio of nanodisk array. The sensitivity of the optimized sensors has been improved, and the detection limit is smaller than that of bare gold-based sensor. The multi-jump resonance angle curves at tiny refractive index can clearly distinguish the difference of trace concentrations, which is very important for the accurate detection of trace substances. SUPPLEMENTARY INFORMATION The online version contains supplementary material available at 10.1007/s11468-023-01802-3.
Collapse
Affiliation(s)
- Yan Guo
- School of Automation, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Xianglong Su
- School of Automation, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Kaihua Wu
- School of Automation, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Ken-Tye Yong
- School of Biomedical Engineering, The University of Sydney, Sydney, Australia
| |
Collapse
|
26
|
Esmailidastjerdipour P, Shahshahani F. Numerical Simulation of Surface Plasmon Resonance Optical Fiber Biosensor Enhanced by Using Alloys for Medical Application. SENSING AND IMAGING 2023; 24:4. [PMID: 36744008 PMCID: PMC9887576 DOI: 10.1007/s11220-022-00409-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 11/27/2022] [Accepted: 12/06/2022] [Indexed: 06/18/2023]
Abstract
Tuberculosis is a very dangerous disease. Therefore, early and quick diagnosis of this disease can increase the chances of overcoming it. Studies show that people with tuberculosis have a lower blood plasma refractive index than healthy people. The performance of the fiber optic sensor based on surface plasmon resonance is investigated for the metal/oxide/graphene structure and for cases where the diameter of the fiber optic core is 300, 600, and 940 µm while blood plasma is considered as the sensing medium. The sensor characteristics such as sensitivity, detection accuracy and figure of merit are simulated for each structure using the theory of matrix method in Wolfram Mathematica software. The simulation results show that the aluminum/lutetium oxide/graphene structure has the highest quality factor when the core diameter of the optical fiber is 940 µm. In continuation of this research, the effects of using alloys with different mixture proportions to improve the quality are investigated. According to results, the structure of aluminum/copper alloy (with a ratio of 30/70)-lutetium oxide graphene is the best choice for improving the quality of the sensor.
Collapse
|
27
|
Balamurugan AM, Parvin T, Alsalem KAJ, Ibrahim SM. Refractive index based optically transparent biosensor device design for early detection of coronavirus. OPTICAL AND QUANTUM ELECTRONICS 2023; 55:507. [PMID: 37065724 PMCID: PMC10082629 DOI: 10.1007/s11082-023-04788-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2023] [Accepted: 03/21/2023] [Indexed: 05/14/2023]
Abstract
For the quick detection of the new Coronavirus (COVID-19), a highly sensitive D-shaped gold-coated surface Plasmon resonance (SPR) biosensor is presented. The COVID-19 virus may be quickly and accurately identified using the SPR-based biosensor, which is essential for halting the spread of this excruciating epidemic. The suggested biosensor is used for detection of the IBV i.e. infectious bronchitis viruses contaminated cell that belongs to the family of COVID-19 having a refractive index of - 0.96, - 0.97, - 0.98, - 0.99, - 1 that is observed with the change in EID concentration. Some important optical parameter variations are examined in the investigation process. Multiphysics version 5.3 with the Finite element method is used for the proposed biosensor. The proposed sensor depicts maximum wavelength sensitivity of 40,141.76 nm/RIU. Some other parameters such as confinement loss, crosstalk, and insertion loss are also analyzed for the proposed sensor. The reported minimum insertion loss for the refractive index (RI) - 1 is 2.9 dB. Simple design, good sensitivity, and lower value of losses make the proposed sensor proficient for the detection of infectious bronchitis viruses belonging to COVID-19. Graphical abstract
Collapse
Affiliation(s)
- A. M. Balamurugan
- Department of ECE, St.Joseph’s College of Engineering, Chennai, 600 119 India
| | - Tarunnum Parvin
- Department of Electronics and Communication, N.I.T Patna, Patna, India
| | - Kasim Abdul Jabar Alsalem
- Department of Medical Instrumentation Engineering Techniques, Al-Kunooze University College, Basra, Iraq
| | - Sobhy M. Ibrahim
- Department of Biochemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh, 11451 Saudi Arabia
| |
Collapse
|
28
|
Bannur Nanjunda S, Seshadri VN, Krishnan C, Rath S, Arunagiri S, Bao Q, Helmerson K, Zhang H, Jain R, Sundarrajan A, Srinivasan B. Emerging nanophotonic biosensor technologies for virus detection. NANOPHOTONICS (BERLIN, GERMANY) 2022; 11:5041-5059. [PMID: 39634299 PMCID: PMC11501160 DOI: 10.1515/nanoph-2022-0571] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/09/2022] [Accepted: 11/13/2022] [Indexed: 12/07/2024]
Abstract
Highly infectious viral diseases are a serious threat to mankind as they can spread rapidly among the community, possibly even leading to the loss of many lives. Early diagnosis of a viral disease not only increases the chance of quick recovery, but also helps prevent the spread of infections. There is thus an urgent need for accurate, ultrasensitive, rapid, and affordable diagnostic techniques to test large volumes of the population to track and thereby control the spread of viral diseases, as evidenced during the COVID-19 and other viral pandemics. This review paper critically and comprehensively reviews various emerging nanophotonic biosensor mechanisms and biosensor technologies for virus detection, with a particular focus on detection of the SARS-CoV-2 (COVID-19) virus. The photonic biosensing mechanisms and technologies that we have focused on include: (a) plasmonic field enhancement via localized surface plasmon resonances, (b) surface enhanced Raman scattering, (c) nano-Fourier transform infrared (nano-FTIR) near-field spectroscopy, (d) fiber Bragg gratings, and (e) microresonators (whispering gallery modes), with a particular emphasis on the emerging impact of nanomaterials and two-dimensional materials in these photonic sensing technologies. This review also discusses several quantitative issues related to optical sensing with these biosensing and transduction techniques, notably quantitative factors that affect the limit of detection (LoD), sensitivity, specificity, and response times of the above optical biosensing diagnostic technologies for virus detection. We also review and analyze future prospects of cost-effective, lab-on-a-chip virus sensing solutions that promise ultrahigh sensitivities, rapid detection speeds, and mass manufacturability.
Collapse
Affiliation(s)
- Shivananju Bannur Nanjunda
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| | - Venkatesh N. Seshadri
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
- Department of Life Science, Indian Academy, Bangalore, India
| | - Chitra Krishnan
- School of Electronics Engineering, Vellore Institute of Technology, Chennai, India
| | - Sweta Rath
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| | | | - Qiaoliang Bao
- Department of Materials Science and Engineering, and ARC Centre of Excellence in Future Low Energy Electronics Technologies (FLEET), Monash University, Clayton, VIC, Australia
| | - Kristian Helmerson
- School of Physics and Astronomy, ARC Centre of Excellence in Future Low-Energy Electronics Technologies (FLEET), Monash University, Clayton, VIC3800, Australia
| | - Han Zhang
- International Collaborative Laboratory of 2D Materials for Optoelectronics Science, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen518060, China
| | - Ravi Jain
- Optical Science and Engineering Program, Center for High Technology Materials, Departments of ECE, Physics Astronomy, and Nanoscience Microsystems, University of New Mexico, Albuquerque, NM87106, USA
| | - Asokan Sundarrajan
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
| | - Balaji Srinivasan
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
29
|
Lee JY, Lim J, Choi JH, Lee BH. Can a wonder material be a popular item? A hype cycle of shifts in the sentiment of the interested public about graphene. TECHNOLOGY ANALYSIS & STRATEGIC MANAGEMENT 2022. [DOI: 10.1080/09537325.2022.2136068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Affiliation(s)
- Ji Yeon Lee
- Department of Science and Technology Management Policy, University of Science and Technology, Daejeon, Korea
- NTIS Center, Korea Institute of Science and Technology Information, Daejeon, Korea
| | - Jeongsub Lim
- School of Media, Arts, and Science, Sogang University, Seoul, Korea
| | - Jae-Hak Choi
- Department of Polymer Science and Engineering, Chungnam National University, Daejeon, Korea
| | - Byeong-Hee Lee
- Department of Science and Technology Management Policy, University of Science and Technology, Daejeon, Korea
- NTIS Center, Korea Institute of Science and Technology Information, Daejeon, Korea
| |
Collapse
|
30
|
Islam A, Haider F, Ahmmed Aoni R, Ahmed R. Plasmonic photonic biosensor: in situ detection and quantification of SARS-CoV-2 particles. OPTICS EXPRESS 2022; 30:40277-40291. [PMID: 36298963 DOI: 10.1364/oe.469937] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/03/2022] [Indexed: 06/16/2023]
Abstract
We conceptualized and numerically investigated a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor for rapid detection and quantification of novel coronavirus. The plasmonic gold-based optical sensor permits three different ways to quantify the virus concentrations inside patient's body based on different ligand-analyte conjugate pairs. This photonic biosensor demonstrates viable detections of SARS-CoV-2 spike receptor-binding-domain (RBD), mutated viral single-stranded ribonucleic acid (RNA) and human monoclonal antibody immunoglobulin G (IgG). A marquise-shaped core is introduced to facilitate efficient light-tailoring. Analytes are dissolved in sterile phosphate buffered saline (PBS) and surfaced on the plasmonic metal layer for realizing detection. The 1-pyrene butyric acid n-hydroxy-succinimide ester is numerically used to immobilize the analytes on the sensing interface. Using the finite element method (FEM), the proposed sensor is studied critically and optimized for the refractive index (RI) range from 1.3348-1.3576, since the target analytes RIs fluctuate within this range depending on the severity of the viral infection. The polarization-dependent sensor exhibits dominant sensing attributes for x-polarized mode, where it shows the average wavelength sensitivities of 2,009 nm/RIU, 2,745 nm/RIU and 1,984 nm/RIU for analytes: spike RBD, extracted coronavirus RNA and antibody IgG, respectively. The corresponding median amplitude sensitivities are 135 RIU-1, 196 RIU-1 and 140 RIU-1, respectively. The maximum sensor resolution and figure of merit are found 2.53 × 10-5 RIU and 101 RIU-1, respectively for viral RNA detection. Also, a significant limit of detection (LOD) of 6.42 × 10-9 RIU2/nm is obtained. Considering modern bioassays, the proposed compact photonic sensor will be well-suited for rapid point-of-care COVID testing.
Collapse
|
31
|
Arano-Martinez JA, Martínez-González CL, Salazar MI, Torres-Torres C. A Framework for Biosensors Assisted by Multiphoton Effects and Machine Learning. BIOSENSORS 2022; 12:710. [PMID: 36140093 PMCID: PMC9496380 DOI: 10.3390/bios12090710] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 08/22/2022] [Accepted: 08/25/2022] [Indexed: 11/25/2022]
Abstract
The ability to interpret information through automatic sensors is one of the most important pillars of modern technology. In particular, the potential of biosensors has been used to evaluate biological information of living organisms, and to detect danger or predict urgent situations in a battlefield, as in the invasion of SARS-CoV-2 in this era. This work is devoted to describing a panoramic overview of optical biosensors that can be improved by the assistance of nonlinear optics and machine learning methods. Optical biosensors have demonstrated their effectiveness in detecting a diverse range of viruses. Specifically, the SARS-CoV-2 virus has generated disturbance all over the world, and biosensors have emerged as a key for providing an analysis based on physical and chemical phenomena. In this perspective, we highlight how multiphoton interactions can be responsible for an enhancement in sensibility exhibited by biosensors. The nonlinear optical effects open up a series of options to expand the applications of optical biosensors. Nonlinearities together with computer tools are suitable for the identification of complex low-dimensional agents. Machine learning methods can approximate functions to reveal patterns in the detection of dynamic objects in the human body and determine viruses, harmful entities, or strange kinetics in cells.
Collapse
Affiliation(s)
- Jose Alberto Arano-Martinez
- Sección de Estudios de Posgrado e Investigación, Escuela Superior de Ingeniería Mecánica y Eléctrica, Unidad Zacatenco, Instituto Politécnico Nacional, Mexico City 07738, Mexico
| | - Claudia Lizbeth Martínez-González
- Sección de Estudios de Posgrado e Investigación, Escuela Superior de Ingeniería Mecánica y Eléctrica, Unidad Zacatenco, Instituto Politécnico Nacional, Mexico City 07738, Mexico
| | - Ma Isabel Salazar
- Departamento de Microbiología, Escuela Nacional de Ciencias Biológicas, Instituto Politécnico Nacional, Mexico City 11340, Mexico
| | - Carlos Torres-Torres
- Sección de Estudios de Posgrado e Investigación, Escuela Superior de Ingeniería Mecánica y Eléctrica, Unidad Zacatenco, Instituto Politécnico Nacional, Mexico City 07738, Mexico
| |
Collapse
|
32
|
Progress and Challenges of Point-of-Need Photonic Biosensors for the Diagnosis of COVID-19 Infections and Immunity. BIOSENSORS 2022; 12:bios12090678. [PMID: 36140063 PMCID: PMC9496547 DOI: 10.3390/bios12090678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/13/2022] [Accepted: 08/16/2022] [Indexed: 11/25/2022]
Abstract
The new coronavirus disease, COVID-19, caused by SARS-CoV-2, continues to affect the world and after more than two years of the pandemic, approximately half a billion people are reported to have been infected. Due to its high contagiousness, our life has changed dramatically, with consequences that remain to be seen. To prevent the transmission of the virus, it is crucial to diagnose COVID-19 accurately, such that the infected cases can be rapidly identified and managed. Currently, the gold standard of testing is polymerase chain reaction (PCR), which provides the highest accuracy. However, the reliance on centralized rapid testing modalities throughout the COVID-19 pandemic has made access to timely diagnosis inconsistent and inefficient. Recent advancements in photonic biosensors with respect to cost-effectiveness, analytical performance, and portability have shown the potential for such platforms to enable the delivery of preventative and diagnostic care beyond clinics and into point-of-need (PON) settings. Herein, we review photonic technologies that have become commercially relevant throughout the COVID-19 pandemic, as well as emerging research in the field of photonic biosensors, shedding light on prospective technologies for responding to future health outbreaks. Therefore, in this article, we provide a review of recent progress and challenges of photonic biosensors that are developed for the testing of COVID-19, consisting of their working fundamentals and implementation for COVID-19 testing in practice with emphasis on the challenges that are faced in different development stages towards commercialization. In addition, we also present the characteristics of a biosensor both from technical and clinical perspectives. We present an estimate of the impact of testing on disease burden (in terms of Disability-Adjusted Life Years (DALYs), Quality Adjusted Life Years (QALYs), and Quality-Adjusted Life Days (QALDs)) and how improvements in cost can lower the economic impact and lead to reduced or averted DALYs. While COVID19 is the main focus of these technologies, similar concepts and approaches can be used and developed for future outbreaks of other infectious diseases.
Collapse
|
33
|
Murillo AMM, Valle LG, Ramírez Y, Sánchez MJ, Santamaría B, Molina-Roldan E, Ortega-Madueño I, Urcelay E, Tramarin L, Herreros P, Díaz-Perales A, Garrido-Arandia M, Tome-Amat J, Hernández-Ramírez G, Espinosa RL, Laguna MF, Holgado M. Integration of Multiple Interferometers in Highly Multiplexed Diagnostic KITs to Evaluate Several Biomarkers of COVID-19 in Serum. BIOSENSORS 2022; 12:bios12090671. [PMID: 36140055 PMCID: PMC9496092 DOI: 10.3390/bios12090671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/16/2022] [Accepted: 08/20/2022] [Indexed: 01/08/2023]
Abstract
In the present work, highly multiplexed diagnostic KITs based on an Interferometric Optical Detection Method (IODM) were developed to evaluate six Coronavirus Disease 2019 (COVID-19)-related biomarkers. These biomarkers of COVID-19 were evaluated in 74 serum samples from severe, moderate, and mild patients with positive polymerase chain reaction (PCR), collected at the end of March 2020 in the Hospital Clínico San Carlos, in Madrid (Spain). The developed multiplexed diagnostic KITs were biofunctionalized to simultaneously measure different types of specific biomarkers involved in COVID-19. Thus, the serum samples were investigated by measuring the total specific Immunoglobulins (sIgT), specific Immunoglobulins G (sIgG), specific Immunoglobulins M (sIgM), specific Immunoglobulins A (sIgA), all of them against SARS-CoV-2, together with two biomarkers involved in inflammatory disorders, Ferritin (FER) and C Reactive Protein (CRP). To assess the results, a Multiple Linear Regression Model (MLRM) was carried out to study the influence of IgGs, IgMs, IgAs, FER, and CRP against the total sIgTs in these serum samples with a goodness of fit of 73.01% (Adjusted R-Squared).
Collapse
Affiliation(s)
- Ana María M. Murillo
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- BioOptical Detection S.L., Centro de Empresas, Campus Montegancedo, 28223 Madrid, Spain
| | - Luis G. Valle
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Yolanda Ramírez
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- BioOptical Detection S.L., Centro de Empresas, Campus Montegancedo, 28223 Madrid, Spain
| | - María Jesús Sánchez
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Beatriz Santamaría
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingeniería y Diseño Industrial, Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain
| | - E. Molina-Roldan
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
| | - Isabel Ortega-Madueño
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
| | - Elena Urcelay
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
| | - Luca Tramarin
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Pedro Herreros
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Araceli Díaz-Perales
- Center for Plant Biotechnology and Genomics (CBGP), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
| | - María Garrido-Arandia
- Center for Plant Biotechnology and Genomics (CBGP), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
| | - Jaime Tome-Amat
- Center for Plant Biotechnology and Genomics (CBGP), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
| | - Guadalupe Hernández-Ramírez
- Center for Plant Biotechnology and Genomics (CBGP), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
| | - Rocío L. Espinosa
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - María F. Laguna
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Miguel Holgado
- Center for Biomedical Technology (CTB), Universidad Politécnica de Madrid, Parque Científico y Tecnológico de la UPM, Campus de Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Health Research Institute of the Hospital Clínico San Carlos, IdISSC. C/Profesor Martín Lagos s/n, 4ª Planta Sur, 28040 Madrid, Spain
- Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
- Correspondence: ; Tel.: +34-91-067-911
| |
Collapse
|
34
|
Mostufa S, Akib TBA, Rana MM, Islam MR. Highly Sensitive TiO 2/Au/Graphene Layer-Based Surface Plasmon Resonance Biosensor for Cancer Detection. BIOSENSORS 2022; 12:bios12080603. [PMID: 36004999 PMCID: PMC9405676 DOI: 10.3390/bios12080603] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/03/2022] [Accepted: 08/04/2022] [Indexed: 05/27/2023]
Abstract
In this article, a hybrid TiO2/Au/graphene layer-based surface plasmon resonance (SPR) sensor with improved sensitivity and capability for cancer detection is presented. The finite element method (FEM) was used for numerical analysis. The proposed SPR biosensor was structured based on the angular analysis of the attenuated total reflection (ATR) method for the detection of various types of cancer using the refractive index component. The resonance angle shifted owing to the increment of normal and cancerous cells' refractive index, which varied between 1.36 and 1.401 for six different types of normal and cancerous cells. According to numerical results, the obtained sensitivities for skin (basal), cervical (HeLa), adrenal gland (PC12), blood (Jurkat), and breast (MCF-7 and MDA-MB-231) cancer cells were 210 deg/RIU, 245.83 deg/RIU, 264.285 deg/RIU, 285.71 deg/RIU, 292.86 deg/RIU, and 278.57 deg/RIU, respectively. Furthermore, the detection accuracy (DA), figure of merits (FOM), and signal-to-noise ratio (SNR) were also obtained, with values of 0.263 deg-1, 48.02 RIU-1, and 3.84, respectively. Additionally, the distribution of the electric field and the propagation of the magnetic field for resonant and non-resonant conditions of the proposed structure were illustrated. It was found that an enhanced field was exhibited on the surface of the plasmonic material for resonant conditions. We also measured the penetration depth of 180 nm using decayed electric field intensity. Furthermore, the impact of using a TiO2/Au/graphene layer was demonstrated. We further conducted analyses of the effects of the thickness of the gold layer and the effects of additional graphene layers on overall sensitivities for six different types of cancer. The proposed TiO2/Au/graphene layered structure exhibited the highest overall sensitivity in terms of detecting cancerous cells from healthy cells. Moreover, the proposed sensor was numerically analyzed for a wide range of biological solutions (refractive index 1.33-1.41), and the sensor linearity was calculated with a linear regression coefficient (R2) of 0.9858. Finally, numerical results obtained in this manuscript exhibited high sensitivity in comparison with previously reported studies.
Collapse
Affiliation(s)
- Shahriar Mostufa
- Department of Electrical & Electronic Engineering, Rajshahi University of Engineering & Technology, Rajshahi 6204, Bangladesh
| | - Tarik Bin Abdul Akib
- Department of Electrical & Electronic Engineering, Rajshahi University of Engineering & Technology, Rajshahi 6204, Bangladesh
| | - Md. Masud Rana
- Department of Electrical & Electronic Engineering, Rajshahi University of Engineering & Technology, Rajshahi 6204, Bangladesh
| | - Md. Rabiul Islam
- School of Electrical, Computer and Telecommfiunications Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| |
Collapse
|
35
|
Szunerits S, Saada H, Pagneux Q, Boukherroub R. Plasmonic Approaches for the Detection of SARS-CoV-2 Viral Particles. BIOSENSORS 2022; 12:548. [PMID: 35884352 PMCID: PMC9313406 DOI: 10.3390/bios12070548] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/18/2022] [Accepted: 07/19/2022] [Indexed: 11/16/2022]
Abstract
The ongoing highly contagious Coronavirus disease 2019 (COVID-19) pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), underlines the fundamental position of diagnostic testing in outbreak control by allowing a distinction of the infected from the non-infected people. Diagnosis of COVID-19 remains largely based on reverse transcription PCR (RT-PCR), identifying the genetic material of the virus. Molecular testing approaches have been largely proposed in addition to infectivity testing of patients via sensing the presence of viral particles of SARS-CoV-2 specific structural proteins, such as the spike glycoproteins (S1, S2) and the nucleocapsid (N) protein. While the S1 protein remains the main target for neutralizing antibody treatment upon infection and the focus of vaccine and therapeutic design, it has also become a major target for the development of point-of care testing (POCT) devices. This review will focus on the possibility of surface plasmon resonance (SPR)-based sensing platforms to convert the receptor-binding event of SARS-CoV-2 viral particles into measurable signals. The state-of-the-art SPR-based SARS-CoV-2 sensing devices will be provided, and highlights about the applicability of plasmonic sensors as POCT for virus particle as well as viral protein sensing will be discussed.
Collapse
Affiliation(s)
- Sabine Szunerits
- University of Lille, CNRS, Centrale Lille, University Polytechnique Hauts-de-France, UMR 8520-IEMN, F-59000 Lille, France; (H.S.); (Q.P.); (R.B.)
| | | | | | | |
Collapse
|
36
|
Pandey PS, Raghuwanshi SK, Shadab A, Ansari MTI, Tiwari UK, Kumar S. SPR Based Biosensing Chip for COVID-19 Diagnosis-A Review. IEEE SENSORS JOURNAL 2022; 22:13800-13810. [PMID: 36346093 DOI: 10.1109/jsen.2021.3133007] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 05/24/2023]
Abstract
Surface Plasmon Resonance (SPR) techniques are highly accurate in detecting biomolecular like blood group measurement, food adulteration, milk adulteration and recently developing as a rapid detection for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. In order to validate the clinical diagnosis, Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) of nasopharyngeal swabs has been utilized, which is time consuming and expensive. For fast and accurate detection of the SARS-CoV-2 virus, SPR based biosensing chips are described in this review article. SPR sensors have the potential to be employed for fast, accurate, and portable SARS-CoV-2 virus diagnosis. To combat the SARS-CoV-2 pandemic, there is considerable interest in creating innovative biosensors that are quick, reliable, and sensitive for COVID-19 diagnosis.
Collapse
Affiliation(s)
- Purnendu Shekhar Pandey
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Sanjeev Kumar Raghuwanshi
- Department of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Azhar Shadab
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Md Tauseef Iqbal Ansari
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Umesh Kumar Tiwari
- Advanced Materials and Sensors DivisionCentral Scientific Instruments Organisation (CSIO) Chandigarh 160030 India
| | - Santosh Kumar
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information TechnologyLiaocheng University Liaocheng 252059 China
| |
Collapse
|
37
|
Pandey PS, Raghuwanshi SK, Shadab A, Ansari MTI, Tiwari UK, Kumar S. SPR Based Biosensing Chip for COVID-19 Diagnosis-A Review. IEEE SENSORS JOURNAL 2022; 22:13800-13810. [PMID: 36346093 PMCID: PMC9423036 DOI: 10.1109/jsen.2022.3181423] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 06/06/2022] [Accepted: 06/06/2022] [Indexed: 05/13/2023]
Abstract
Surface Plasmon Resonance (SPR) techniques are highly accurate in detecting biomolecular like blood group measurement, food adulteration, milk adulteration and recently developing as a rapid detection for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. In order to validate the clinical diagnosis, Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) of nasopharyngeal swabs has been utilized, which is time consuming and expensive. For fast and accurate detection of the SARS-CoV-2 virus, SPR based biosensing chips are described in this review article. SPR sensors have the potential to be employed for fast, accurate, and portable SARS-CoV-2 virus diagnosis. To combat the SARS-CoV-2 pandemic, there is considerable interest in creating innovative biosensors that are quick, reliable, and sensitive for COVID-19 diagnosis.
Collapse
Affiliation(s)
- Purnendu Shekhar Pandey
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Sanjeev Kumar Raghuwanshi
- Department of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Azhar Shadab
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Md Tauseef Iqbal Ansari
- Optical Fiber Sensor LaboratoryDepartment of Electronics EngineeringIndian Institute of Technology (Indian School of Mines) Dhanbad Dhanbad Jharkhand 826004 India
| | - Umesh Kumar Tiwari
- Advanced Materials and Sensors DivisionCentral Scientific Instruments Organisation (CSIO) Chandigarh 160030 India
| | - Santosh Kumar
- Shandong Key Laboratory of Optical Communication Science and Technology, School of Physics Science and Information TechnologyLiaocheng University Liaocheng 252059 China
| |
Collapse
|
38
|
Wu Q, Wu W, Chen F, Ren P. Highly sensitive and selective surface plasmon resonance biosensor for the detection of SARS-CoV-2 spike S1 protein. Analyst 2022; 147:2809-2818. [PMID: 35616214 DOI: 10.1039/d2an00426g] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The reality that the coronavirus disease 2019 (COVID-19) is still raging around the world and making a comeback with a strong presence has highlighted the need for rapid and sensitive quantitative detection methods of viral RNA, antibody and antigen for widespread tracking and screening applications. Surface plasmon resonance (SPR) detection technology has achieved rapid development and become a standard measurement method in the fields of biosensing, biomedicine, biochemistry and biopharmaceuticals due to its advantages of high sensitivity, fast response and no need for labelling. Here, we report a sandwiched structure-based SPR biosensor for detecting a specific viral antigen, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike S1 protein. The sensor combines a Ti3C2-MXene nanosheet modified sensing platform and polydopamine (PDA)-Ag nanoparticle (AgNP)/anti-SARS-CoV-2 spike S1 protein nanoconjugate signal enhancers, exhibiting a wide linear range of 0.0001 to 1000 ng mL-1 with a low detection limit of 12 fg mL-1 (S/N = 3). In the analysis of artificial saliva and human serum samples, the proposed SPR biosensor exhibits good reproducibility and high specificity, which indicates its potential for application in complex bodily fluids. The exploitation of the MXene-based SPR biochip for recognizing the SARS-CoV-2 antigen provides an accessible and rapid way for COVID-19 diagnosis, and promotes the application of 2D nanomaterial-based sensing chips in clinical diagnosis and disease screening. Significantly, the proposed method possesses general applicability that can be reprogrammed to detect any protein antigen if a corresponding specific nanobody is available.
Collapse
Affiliation(s)
- Qiong Wu
- Nanomedicine Translational Research Center, China-Japan Union Hospital of Jilin University, 126 Sendai Street, Changchun 130033, Jilin, China
| | - Wen Wu
- Nanomedicine Translational Research Center, China-Japan Union Hospital of Jilin University, 126 Sendai Street, Changchun 130033, Jilin, China
| | - Fangfang Chen
- Nanomedicine Translational Research Center, China-Japan Union Hospital of Jilin University, 126 Sendai Street, Changchun 130033, Jilin, China
| | - Ping Ren
- Department of Thoracic Surgery, The First Hospital of Jilin University, 71 Xinmin Street, Changchun 130021, Jilin, China.
| |
Collapse
|
39
|
Wang Y, Xie Y, Jiang H, Wu P. Narrow-Bandpass One-Step Leapfrog Hybrid Implicit-Explicit Algorithm with Convolutional Boundary Condition for Its Applications in Sensors. SENSORS 2022; 22:s22124445. [PMID: 35746226 PMCID: PMC9229724 DOI: 10.3390/s22124445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/07/2022] [Accepted: 06/09/2022] [Indexed: 11/21/2022]
Abstract
A large number of sensors work in the narrow bandpass circumstance. Meanwhile, some of them hold fine details merely along one and two dimensions. In order to efficiently simulate these sensors and devices, the one-step leapfrog hybrid implicit-explicit (HIE) algorithm with the complex envelope (CE) method and absorbing boundary condition is proposed in the narrow bandpass circumstance. To be more precise, absorbing boundary condition is implemented by the higher order convolutional perfectly matched layer (CPML) formulation to further enhance the absorption during the entire simulation. Numerical examples and their experiments are carried out to further illustrate the effectiveness of the proposed algorithm. The results show considerable agreement with the experiment and theory resolution. The relationship between the time step and mesh size can break the Courant–Friedrichs–Levy condition which indicates the physical size/selection mesh size. Such a condition indicates that the proposed algorithm behaviors are considerably accurate due to the rational choice in discretized mesh. It also shows decrement in simulation duration and memory consumption compared with the other algorithms. In addition, absorption performance can be improved by employing the proposed higher order CPML algorithm during the whole simulation.
Collapse
Affiliation(s)
- Yangjing Wang
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (Y.W.); (Y.X.)
- Beijing Key Laboratory of Microwave Sensing and Security Applications, Beihang University, Beijing 100191, China
- Shenzhen Institute of Beihang University, Shenzhen 518000, China
- Xi’an Institute of Space Radio Technology, Xi’an 710100, China
| | - Yongjun Xie
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (Y.W.); (Y.X.)
- Beijing Key Laboratory of Microwave Sensing and Security Applications, Beihang University, Beijing 100191, China
- Shenzhen Institute of Beihang University, Shenzhen 518000, China
| | - Haolin Jiang
- School of Electronic and Information Engineering, Nanjing University of Information Science and Technology, Nanjing 210096, China;
| | - Peiyu Wu
- School of Electronic and Information Engineering, Beihang University, Beijing 100191, China; (Y.W.); (Y.X.)
- Beijing Key Laboratory of Microwave Sensing and Security Applications, Beihang University, Beijing 100191, China
- Shenzhen Institute of Beihang University, Shenzhen 518000, China
- Correspondence:
| |
Collapse
|
40
|
Yasri S, Wiwanitkit V. Sustainable materials and COVID-19 detection biosensor: A brief review. SENSORS INTERNATIONAL 2022; 3:100171. [PMID: 35284845 PMCID: PMC8904007 DOI: 10.1016/j.sintl.2022.100171] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/04/2022] [Accepted: 03/05/2022] [Indexed: 12/23/2022] Open
Abstract
COVID-19 is the current global problem. Billions of infected cases due to the pandemic cause an emergency requirement to contain the pandemic. A basic concept to manage the outbreak is an early diagnosis and prompt treatment. To diagnose COVID-19, the new biosensors become new interventions that are hopeful to help effective diagnosis. In clinical material science, the issues on materials of COVID-19 detection biosensor is very interesting. In this brief review, the authors summarize and discuss on sustainable materials and COVID-19 detection biosensor. The paper, cellulose and graphene - based materials are specifically focused and biosensors for RNA sensing, antigenic determination and immune response detection are covered in this short article.
Collapse
|
41
|
Lin Z, Shu Y, Chen W, Zhao Y, Li J. High-Sensitivity PtSe 2 Surface Plasmon Resonance Biosensor Based on Metal-Si-Metal Waveguide Structure. BIOSENSORS 2022; 12:27. [PMID: 35049655 PMCID: PMC8773956 DOI: 10.3390/bios12010027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 01/02/2022] [Accepted: 01/04/2022] [Indexed: 06/14/2023]
Abstract
PtSe2 as a novel TMDCs material is used to modify the traditional SPR biosensors to improve the performance. On this basis, this research proposes a metal-Si-metal waveguide structure to further improve the performance of the biosensor. In this study, we not only studied the effects of waveguide structures containing different metals on the performance of biosensor, but also discussed the performance change of the biosensor with the change of PtSe2 thickness. After the final optimization, a BK7-Au-Si-Au-PtSe2 (2 nm) biosensor structure achieved the highest sensitivity of 193.8°/RIU. This work provides a new development idea for the study of SPR biosensors with waveguide structures in the future.
Collapse
Affiliation(s)
- Zhitao Lin
- Faculty of Information Technology, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macao 999078, China; (Z.L.); (Y.S.)
| | - Yiqing Shu
- Faculty of Information Technology, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macao 999078, China; (Z.L.); (Y.S.)
- Guangdong-HongKong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, Foshan University, Foshan 528225, China;
| | - Weicheng Chen
- Guangdong-HongKong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, Foshan University, Foshan 528225, China;
| | - Yang Zhao
- Weihai City Key Laboratory of Photoacoustic Testing and Sensing, Harbin Institute of Technology (Weihai), Weihai 264209, China;
| | - Jianqing Li
- Faculty of Information Technology, Macau University of Science and Technology, Avenida Wai Long, Taipa, Macao 999078, China; (Z.L.); (Y.S.)
- Zhuhai MUST Science & Technology Research Institute, Zhuhai 519000, China
| |
Collapse
|
42
|
Ebrahimi M, Asadi M, Akhavan O. Graphene-based Nanomaterials in Fighting the Most Challenging Viruses and Immunogenic Disorders. ACS Biomater Sci Eng 2021; 8:54-81. [PMID: 34967216 DOI: 10.1021/acsbiomaterials.1c01184] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Viral diseases have long been among the biggest challenges for healthcare systems around the world. The recent Coronavirus Disease 2019 (COVID-19) pandemic is an example of how complicated the situation can get if we are not prepared to combat a viral outbreak in time, which brings up the need for quick and affordable biosensing platforms and vast knowledge of potential antiviral effects and drug/gene delivery opportunities. The same challenges have also existed for nonviral immunogenic disorders. Nanomedicine is considered a novel candidate for effectively overcoming these worldwide challenges. Among the versatile nanomaterials commonly used in biomedical applications, graphene has recently earned much attention thanks to its special and inspiring physicochemical properties, such as its large surface area, efficient thermal/electrical properties, carbon-based chemical purity with controllable biocompatibility, easy functionalization, capability of single-molecule detection, anticancer characteristics, 3D template feature in tissue engineering, and, in particular, antibacterial/antiviral activities. In this Review, the most important and challenging viruses of our era, such as human immunodeficiency virus, Ebola, SARS-CoV-2, norovirus, and hepatitis virus, and immunogenic disorders, such as asthma, Alzheimer's disease, and Parkinson's disease, in which graphene-based nanomaterials can effectively take part in the prevention, detection, treatment, medication, and health effect issues, have been covered and discussed.
Collapse
Affiliation(s)
- Mahsa Ebrahimi
- Department of Physics, Sharif University of Technology, 11155-9161 Tehran, Islamic Republic of Iran
| | - Mohamad Asadi
- Department of Electrical Engineering, Sharif University of Technology, 11155-4363 Tehran, Islamic Republic of Iran
| | - Omid Akhavan
- Department of Physics, Sharif University of Technology, 11155-9161 Tehran, Islamic Republic of Iran
| |
Collapse
|
43
|
Afroj S, Britnell L, Hasan T, Andreeva DV, Novoselov KS, Karim N. Graphene-Based Technologies for Tackling COVID-19 and Future Pandemics. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2107407. [PMID: 34899114 PMCID: PMC8646295 DOI: 10.1002/adfm.202107407] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/27/2021] [Indexed: 05/06/2023]
Abstract
The COVID-19 pandemic highlighted the need for rapid tools and technologies to combat highly infectious viruses. The excellent electrical, mechanical and other functional properties of graphene and graphene-like 2D materials (2DM) can be utilized to develop novel and innovative devices to tackle COVID-19 and future pandemics. Here, the authors outline how graphene and other 2DM-based technologies can be used for the detection, protection, and continuous monitoring of infectious diseases including COVID-19. The authors highlight the potential of 2DM-based biosensors in rapid testing and tracing of viruses to enable isolation of infected patients, and stop the spread of viruses. The possibilities of graphene-based wearable devices are discussed for continuous monitoring of COVID-19 symptoms. The authors also provide an overview of the personal protective equipment, and potential filtration mechanisms to separate, destroy or degrade highly infectious viruses, and the potential of graphene and other 2DM to increase their efficiency, and enhance functional and mechanical properties. Graphene and other 2DM could not only play a vital role for tackling the ongoing COVID-19 pandemic but also provide technology platforms and tools for the protection, detection and monitoring of future viral diseases.
Collapse
Affiliation(s)
- Shaila Afroj
- Centre for Print Research The University of West of EnglandBristolBS16 1QYUK
| | - Liam Britnell
- Graphene Engineering and Innovation Centre (GEIC)The University of ManchesterManchesterM13 9PLUK
| | - Tahmid Hasan
- Department of Environmental Science and EngineeringBangladesh University of TextilesTejgaonDhaka 1208Bangladesh
| | - Daria V. Andreeva
- Department of Materials Science and EngineeringNational University of SingaporeSingaporeSingapore
- Institute for Functional Intelligent MaterialsNational University of SingaporeSingaporeSingapore
| | - Kostya S. Novoselov
- Department of Materials Science and EngineeringNational University of SingaporeSingaporeSingapore
- Institute for Functional Intelligent MaterialsNational University of SingaporeSingaporeSingapore
- Chongqing 2D Materials InstituteLiangjiang New AreaChongqing400714China
| | - Nazmul Karim
- Centre for Print Research The University of West of EnglandBristolBS16 1QYUK
| |
Collapse
|
44
|
Lim WY, Lan BL, Ramakrishnan N. Emerging Biosensors to Detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2): A Review. BIOSENSORS 2021; 11:bios11110434. [PMID: 34821650 PMCID: PMC8615996 DOI: 10.3390/bios11110434] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 05/07/2023]
Abstract
Coronavirus disease (COVID-19) is a global health crisis caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) is the gold standard test for diagnosing COVID-19. Although it is highly accurate, this lab test requires highly-trained personnel and the turn-around time is long. Rapid and inexpensive immuno-diagnostic tests (antigen or antibody test) are available, but these point of care (POC) tests are not as accurate as the RT-PCR test. Biosensors are promising alternatives to these rapid POC tests. Here we review three types of recently developed biosensors for SARS-CoV-2 detection: surface plasmon resonance (SPR)-based, electrochemical and field-effect transistor (FET)-based biosensors. We explain the sensing principles and discuss the advantages and limitations of these sensors. The accuracies of these sensors need to be improved before they could be translated into POC devices for commercial use. We suggest potential biorecognition elements with highly selective target-analyte binding that could be explored to increase the true negative detection rate. To increase the true positive detection rate, we suggest two-dimensional materials and nanomaterials that could be used to modify the sensor surface to increase the sensitivity of the sensor.
Collapse
|
45
|
Chen R, Kan L, Duan F, He L, Wang M, Cui J, Zhang Z, Zhang Z. Surface plasmon resonance aptasensor based on niobium carbide MXene quantum dots for nucleocapsid of SARS-CoV-2 detection. Mikrochim Acta 2021; 188:316. [PMID: 34476615 PMCID: PMC8412382 DOI: 10.1007/s00604-021-04974-z] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 08/11/2021] [Indexed: 12/19/2022]
Abstract
A novel label-free surface plasmon resonance (SPR) aptasensor has been constructed for the detection of N-gene of SARS-CoV-2 by using thiol-modified niobium carbide MXene quantum dots (Nb2C-SH QDs) as the bioplatform for anchoring N-gene-targeted aptamer. In the presence of SARS-CoV-2 N-gene, the immobilized aptamer strands changed their conformation to specifically bind with N-gene. It thus increased the contact area or enlarged the distance between aptamer and the SPR chip, resulting in a change of the SPR signal irradiated by the laser (He-Ne) with the wavelength (λ) of 633 nm. Nb2C QDs were derived from Nb2C MXene nanosheets via a solvothermal method, followed by functionalization with octadecanethiol through a self-assembling method. Subsequently, the gold chip for SPR measurements was modified with Nb2C-SH QDs via covalent binding of the Au-S bond also by self-assembling interaction. Nb2C-SH QDs not only resulted in high bioaffinity toward aptamer but also enhanced the SPR response. Thus, the Nb2C-SH QD-based SPR aptasensor had low limit of detection (LOD) of 4.9 pg mL-1 toward N-gene within the concentration range 0.05 to 100 ng mL-1. The sensor also showed excellent selectivity in the presence of various respiratory viruses and proteins in human serum and high stability. Moreover, the Nb2C-SH QD-based SPR aptasensor displayed a vast practical application for the qualitative analysis of N-gene from different samples, including seawater, seafood, and human serum. Thus, this work can provide a deep insight into the construction of the aptasensor for detecting SARS-CoV-2 in complex environments. A novel label-free surface plasmon resonance aptasensor has been constructed to detect sensitively and selectively the N-gene of SARS-CoV-2 by using thiol-modified niobium carbide MXene quantum dots as the scaffold to anchor the N-gene-targeted aptamer.
Collapse
Affiliation(s)
- Rongyuan Chen
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Lun Kan
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Fenghe Duan
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Linghao He
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Minghua Wang
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Jing Cui
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China
| | - Zhihong Zhang
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China.
| | - Zhonghou Zhang
- College of Material and Chemical Engineering, Zhengzhou University of Light Industry, No. 136, Science Avenue, Zhengzhou, 450001, People's Republic of China.
| |
Collapse
|
46
|
Takemura K. Surface Plasmon Resonance (SPR)- and Localized SPR (LSPR)-Based Virus Sensing Systems: Optical Vibration of Nano- and Micro-Metallic Materials for the Development of Next-Generation Virus Detection Technology. BIOSENSORS 2021; 11:250. [PMID: 34436053 PMCID: PMC8391291 DOI: 10.3390/bios11080250] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 07/13/2021] [Accepted: 07/23/2021] [Indexed: 01/04/2023]
Abstract
The global damage that a widespread viral infection can cause is evident from the ongoing COVID-19 pandemic. The importance of virus detection to prevent the spread of viruses has been reaffirmed by the pandemic and the associated social and economic damage. Surface plasmon resonance (SPR) in microscale and localized SPR (LSPR) in nanoscale virus sensing systems are thought to be useful as next-generation detection methods. Many studies have been conducted on ultra-sensitive technologies, especially those based on signal amplification. In some cases, it has been reported that even a low viral load can be measured, indicating that the virus can be detected in patients even in the early stages of the viral infection. These findings corroborate that SPR and LSPR are effective in minimizing false-positives and false-negatives that are prevalent in the existing virus detection techniques. In this review, the methods and signal responses of SPR and LSPR-based virus detection technologies are summarized. Furthermore, this review surveys some of the recent developments reported and discusses the limitations of SPR and LSPR-based virus detection as the next-generation detection technologies.
Collapse
Affiliation(s)
- Kenshin Takemura
- Sensing System Research Center, The National Institute of Advanced Industrial Science and Technology, 07-1 Shuku-Machi, Tosu 841-0052, Japan
| |
Collapse
|
47
|
Kharlamov AA, Raskhodchikov AN, Pilgun M. Smart City Data Sensing during COVID-19: Public Reaction to Accelerating Digital Transformation. SENSORS (BASEL, SWITZERLAND) 2021; 21:3965. [PMID: 34201395 PMCID: PMC8228338 DOI: 10.3390/s21123965] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/02/2021] [Accepted: 06/06/2021] [Indexed: 12/23/2022]
Abstract
The article presents the results of the analysis of the adaptation of metropolis IT technologies to solve operational problems in extreme conditions during the COVID-19 pandemic. The material for the study was Russian-language data from social networks, microblogging, blogs, instant messengers, forums, reviews, video hosting services, thematic portals, online media, print media and TV related to the first wave of the COVID-19 pandemic in Russia. The data were collected between 1 March 2020 and 1 June 2020. The database size includes 85,493,717 characters. To analyze the content of social media, a multimodal approach was used involving neural network technologies, text analysis, sentiment-analysis and analysis of lexical associations. The transformation of old digital services and applications, as well as the emergence of new ones were analyzed in terms of the perception of digital communications by actors.
Collapse
Affiliation(s)
- Alexander A Kharlamov
- Institute of Higher Nervous Activity and Neurophysiology, Russian Academy of Sciences, 117865 Moscow, Russia
| | | | - Maria Pilgun
- Institute of Linguistics, Russian Academy of Sciences, 125009 Moscow, Russia
| |
Collapse
|