1
|
First national survey of residues of active substances in honeybee apiaries across Spain between 2012 and 2016. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 838:155614. [PMID: 35504369 DOI: 10.1016/j.scitotenv.2022.155614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 04/26/2022] [Accepted: 04/26/2022] [Indexed: 06/14/2023]
Abstract
This nationwide monitoring aimed to investigate the prevalence of residues of plant protection products (PPPs) and veterinary medicine products (VMPs) based on random selection of apiaries of Apis mellifera. For a three-year period (2012, 2013 and 2016), this study targeted 306 PPPs, VMPs and other active substances in 442 samples of bee bread honeycomb (BBHC) and 89 samples of honeybees collected from up to 177 apiaries. The results indicate that honeybees were most often exposed to residues of coumaphos, tau-fluvalinate, chlorfenvinphos, and acrinathrin, with a prevalence from a maximum of 98.8% to 49.4% in BBHC samples. Residues of coumaphos, tau-fluvalinate, amitraz (DMF + DMPF), carbendazim and orthophenylphenol were also frequently detected, from a maximum of 55.1% to 13.5% of the honeybee samples. Neonicotinoid residues, namely clothianidin and thiamethoxam, whose outdoor uses in crops are completely banned in EU, were not detected. Imidacloprid was found in 3.4% to 13.3% of samples during 2013 and 2016, respectively. Imidacloprid exceeded its acute toxicity (LD50) value for honey bees in two samples of BBHC. Fipronil was detected in 0.5% of the samples during 2013. The diversity of active substances found (% of different residues analyzed) ranged from 33.9% to 37.2% in BBHC from 2012, 2013 to 2016, and was of 26.5% in honeybees in 2016. In at least 54% of the samples, the total residue load was in the range of 200 to 1500 μg·kg-1. Up to 50% of BBHC samples were positive for one or two residues. No toxic residues for honeybees were detected in up to 88.8% of bee samples. This systematic surveillance of active substances assisted the evaluation of which target pesticides to look for and provided support to the competent authorities in the bee health decision-making.
Collapse
|
2
|
A three-year large scale study on the risk of honey bee colony exposure to blooming sunflowers grown from seeds treated with thiamethoxam and clothianidin neonicotinoids. CHEMOSPHERE 2021; 262:127735. [PMID: 32777610 DOI: 10.1016/j.chemosphere.2020.127735] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2019] [Revised: 07/12/2020] [Accepted: 07/14/2020] [Indexed: 06/11/2023]
Abstract
Despite the restriction of the use of neonicotinoids in the EU, including thiamethoxam and clothianidin, the debate over their risk on honey bees has not been fully settled. This study presents results of a three-year study working with 180 honey bee colonies in ten replicates. Colonies were sorted into three treatments (60 colonies per treatment) exposed to sunflower blooms grown from seeds treated with thiamethoxam, clothianidin and a non-treated control. Each colony was assessed at six moments: one before to exposition to sunflower, two during the exposition (short-time risk), two after exposition (medium-time risk) and one after wintering (long-time risk). The health and development of the colonies were assessed by monitoring adult bee population, brood development, status of the queen, food reserves and survival. No significant difference among treatments when raw data was considered. However, when evolution from initial status of the colony was evaluated, a significant difference was observed from the first week of exposure to sunflower blooms. In this period, the number of adult bees and the amount of brood were slightly lower in the bee hives exposed to neonicotinoids, although such differences disappeared in subsequent evaluations. The concentration of residues in samples of beebread and adult bees was at the level of ng·g-1. Magnitude of the effect of the treatment factor on the variability of colony health and development related parameters was low. The most important factor was the hive, followed by the replicate and year, and to a lesser extent the initial strength of the colonies.
Collapse
|
3
|
Quantitative determination of pesticide residues in specific parts of bee specimens by nanoflow liquid chromatography high resolution mass spectrometry. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 715:137005. [PMID: 32041002 DOI: 10.1016/j.scitotenv.2020.137005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Revised: 01/27/2020] [Accepted: 01/28/2020] [Indexed: 06/10/2023]
Abstract
The presence of pesticide residues in bees is of great interest, given the central role of bees as indicators for environmental assessment. The goal of this article is to propose a method to capture enhanced chemical information for these central environmental indicators. Most of the methods rely on the analysis of pooled samples rather than individual specimens due to practical sample preparation method considerations and limitations in sensitivity. This leads to miss information on the mapping of pesticides and actual amount of pesticide per specimen. In this article, a nanoflow liquid chromatography system coupled to high resolution mass spectrometry (using a hybrid quadrupole-Orbitrap instrument) has been applied for the development of a multiresidue pesticide method for the determination of 162 multiclass pesticides in specific part of honeybee samples (ca. abdomen, head or thorax). The reduced flow rate provided an enhancement in sensitivity and a strong reduction of matrix effects, thus only a quick and simple ultrasound assisted extraction using minute amount of sample was required. Satisfactory results were obtained for all tested analytes with concentration levels detected lower than 0.5 ng g-1 in all cases, thus being acceptable for monitoring purposes. Matrix effect was negligible for 94% of compounds. Extraction recoveries ranged from 70% to 105%, being within SANTE guidelines. Finally, the applicability of the method was demonstrated, by successful application to the analysis of contaminated honeybee samples, extracting useful information from specific bee parts of single specimens, thus, enabling pseudo spatially resolved chemical information.
Collapse
|
4
|
Exploration of environmental contaminants in honeybees using GC-TOF-MS and GC-Orbitrap-MS. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 647:232-244. [PMID: 30081361 DOI: 10.1016/j.scitotenv.2018.08.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 08/01/2018] [Accepted: 08/01/2018] [Indexed: 06/08/2023]
Abstract
This study reports an analytical approach by gas chromatography and high-resolution mass spectrometry (HRMS) intended to be used for investigation of non-targeted environmental contaminants in honeybees. The approach involves a generic extraction and analysis with two GC-HRMS systems: time-of-flight and Orbitrap analyzers, GC-TOF-MS, and GC-Orbitrap-MS operated in electron-impact ionization (EI) mode. The workflow for screening of non-targeted contaminants consisted of initial peak detection by deconvolution and matching the first-stage mass spectra EI-MS with a nominal mass spectral library. To gain further confidence in the structural characterization of the contaminants under investigation, molecular formula of representative ions (molecular and fragment ions) was provided for those with an accurate mass scoring (error < 5 ppm). This methology was applied for screening environmental contaminants in 75 samples of adult honeybee. This approach has provided the tentative identification of environmental contaminants belonging to different chemical groups, among them, PAHs, phthalates and synthetic musks. Residues of veterinary treatments used in apiculture were also detected in the honeybee samples.
Collapse
|
5
|
Viability of honeybee colonies exposed to sunflowers grown from seeds treated with the neonicotinoids thiamethoxam and clothianidin. CHEMOSPHERE 2018; 202:609-617. [PMID: 29597178 DOI: 10.1016/j.chemosphere.2018.03.115] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Revised: 03/16/2018] [Accepted: 03/17/2018] [Indexed: 06/08/2023]
Abstract
In this study, honeybee colonies were monitored in a field study conducted on sunflowers grown from seeds treated with the systemic neonicotinoids thiamethoxam or clothianidin. This field trial was carried out in different representative growing areas in Spain over a beekeeping season. The health and development of the colonies was assessed by measuring factors that have a significant influence on their strength and overwintering ability. The parameters assessed were: colony strength (adult bees), brood development, amount of pollen and honey stores and presence and status of the queen. The concentration of residues (clothianidin and thiamethoxam) in samples of beebread and in adult bees was at the level of ng.g-1; in the ranges of 0.10-2.89 ng g-1 and 0.05-0.12 ng g-1; 0.10-0.37 ng g-1 and 0.01-0.05 ng g-1, respectively. Multivariate models were applied to evaluate the interaction among factors. No significant differences were found between the honeybee colonies of the different treatment groups, either exposed or not to the neonicotinoids. The seasonal development of the colonies was affected by the environmental conditions which, together with the initial strength of the bee colonies and the characteristics of the plots, had a significant effect on the different variables studied.
Collapse
|
6
|
Non-target evaluation of contaminants in honey bees and pollen samples by gas chromatography time-of-flight mass spectrometry. CHEMOSPHERE 2017; 184:1310-1319. [PMID: 28679151 DOI: 10.1016/j.chemosphere.2017.06.089] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 06/16/2017] [Accepted: 06/19/2017] [Indexed: 06/07/2023]
Abstract
This work presents a non-targeted screening approach for the detection and quantitation of contaminants in bees and pollen, collected from the same hive, by GC-EI-ToF-MS. It consists of a spectral library datasets search using a compound database followed by a manual investigation and analytical standard confirmation together with semi-quantitation purposes. Over 20% of the compounds found automatically by the library search could not be confirmed manually. This number of false positive detections was mainly a consequence of an inadequate ion ratio criterion (±30%), not considered in the automatic searching procedure. Eight compounds were detected in bees and pollen. They include insecticides/acaricides (chlorpyrifos, coumaphos, fluvalinate-tau, chlorfenvinphos, pyridaben, and propyl cresol) at a concentration range of 1-1207 μg kg-1, herbicides (oxyfluorfen) at a concentration range of 212-1773 μg kg-1 and a growth regulator hormone (methoprene). Some compounds were detected only in pollen; such as herbicides (clomazone), insecticides/acaricides and fungicides used to control Varroa mites as benzylbenzoate, bufencarb, allethrin, permethrin, eugenol and cyprodinil. Additional compounds were detected only in bees: flamprop-methyl, 2-methylphenol (2-49 μg kg-1) and naphthalene (1-23 μg kg-1). The proposed method presents important advantages as it can avoid the use of an unachievable number of analytical standards considered target compounds "a priori" but not present in the analyzed samples.
Collapse
|
7
|
Screening of pesticide residues in honeybee wax comb by LC-ESI-MS/MS. A pilot study. CHEMOSPHERE 2016; 163:44-53. [PMID: 27522180 DOI: 10.1016/j.chemosphere.2016.07.008] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Revised: 06/10/2016] [Accepted: 07/03/2016] [Indexed: 06/06/2023]
Abstract
A developed multi-residue method using microflow-LC-ESI-QqQ-MS provided a wide-scope analysis for medium-polar and polar pesticide residues (120 compounds including breakdown products). Honeybee wax comb samples were extracted using a generic QuEChERS based procedure. Acceptable recoveries at concentration levels of 5 and 50 μg kg(-1) were within the 70-120% range with an associated precision RSD <20%. The LOQ values were mostly 5 μg kg(-1) for almost all pesticides. Aprox. 31 of 120 LC-amenable pesticides tested (25.8%) were detected in a pilot study of 60 samples. Pesticide residues detected using the proposed method were: the breakdown products of amitraz, DMPF and DMF, an acaricide used for Varroa mite control, with a range of concentration from 5 to 464 μg kg(-1) (sum of DMPF + DMF), organophosphate insecticides from 1 to 464 μg kg(-1), acaricides at concentrations > 9 μg kg(-1); fungicides at concentrations ranging from 1 to 23 μg kg(-1.) The number of positive detections due to herbicides was lower as expected and at a lower level of concentration, from 1 to 5.9 μg kg(-1).
Collapse
|
8
|
Screening of environmental contaminants in honey bee wax comb using gas chromatography-high-resolution time-of-flight mass spectrometry. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:4609-4620. [PMID: 26527334 DOI: 10.1007/s11356-015-5667-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 10/20/2015] [Indexed: 06/05/2023]
Abstract
This study reports an analytical approach intended to be used for investigation of non-targeted environmental contaminants and to characterize the organic pollution pattern of bee wax comb samples. The method comprises a generic extraction followed by detection with gas chromatography coupled to high-resolution time-of-flight mass spectrometry (GC-TOF-MS), operated in electron impact ionization (EI) mode. The screening approach for the investigation of non-targeted contaminants consisted of initial peak detection by deconvolution and matching the first-stage mass spectra EI-MS(1) with a nominal mass spectral library. To gain further confidence in the structural characterization of the contaminants under investigation, the molecular formula of representative ions (molecular ion when present in the EI spectrum) and, for at least other two fragment ions, was provided for those with an accurate mass scoring (mass error < 5 ppm). This methodology was applied for screening environmental contaminants in 50 samples of bee wax comb. This approach has allowed the tentative identification of some GC-amenable contaminants belonging to different chemical groups, among them, phthalates and polycyclic aromatic hydrocarbons (PAHs), along with residues of veterinary treatments used in apiculture.
Collapse
|
9
|
Post-acquisition data processing for the screening of transformation products of different organic contaminants. Two-year monitoring of river water using LC-ESI-QTOF-MS and GCxGC-EI-TOF-MS. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2014; 21:12583-12604. [PMID: 24952251 DOI: 10.1007/s11356-014-3187-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2014] [Accepted: 06/09/2014] [Indexed: 06/03/2023]
Abstract
This study describes a comprehensive strategy for detecting and elucidating the chemical structures of expected and unexpected transformation products (TPs) from chemicals found in river water and effluent wastewater samples, using liquid chromatography coupled to electrospray ionization quadrupole-time-of-flight mass spectrometer (LC-ESI-QTOF-MS), with post-acquisition data processing and an automated search using an in-house database. The efficacy of the mass defect filtering (MDF) approach to screen metabolites from common biotransformation pathways was tested, and it was shown to be sufficiently sensitive and applicable for detecting metabolites in environmental samples. Four omeprazole metabolites and two venlafaxine metabolites were identified in river water samples. This paper reports the analytical results obtained during 2 years of monitoring, carried out at eight sampling points along the Henares River (Spain). Multiresidue monitoring, for targeted analysis, includes a group of 122 chemicals, amongst which are pharmaceuticals, personal care products, pesticides and PAHs. For this purpose, two analytical methods were used based on direct injection with a LC-ESI-QTOF-MS system and stir bar sorptive extraction (SBSE) with bi-dimensional gas chromatography coupled with a time-of-flight spectrometer (GCxGC-EI-TOF-MS).
Collapse
|
10
|
Simultaneous screening of targeted and non-targeted contaminants using an LC-QTOF-MS system and automated MS/MS library searching. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:878-93. [PMID: 25230185 DOI: 10.1002/jms.3428] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/08/2014] [Revised: 06/25/2014] [Accepted: 06/29/2014] [Indexed: 05/27/2023]
Abstract
Simultaneous high-resolution full-scan and tandem mass spectrometry (MS/MS) analysis using time of flight mass spectrometry brings an answer for increasing demand of retrospective and non-targeted data analysis. Such analysis combined with spectral library searching is a promising tool for targeted and untargeted screening of small molecules. Despite considerable extension of the panel of compounds of tandem mass spectral libraries, the heterogeneity of spectral data poses a major challenge against the effective usage of spectral libraries. Performance evaluation of available LC-MS/MS libraries will significantly increase credibility in the search results. The present work was aimed to evaluate fluctuation of MS/MS pattern, in the peak intensities distribution together with mass accuracy measurements, and in consequence, performance compliant with ion ratio and mass error criteria as principles in identification processes for targeted and untargeted contaminants at trace levels. Matrix effect and ultra-trace levels of concentration (from 50 ng l(-1) to 1000 ng l(-1) were evaluated as potential source of inaccuracy in the performance of spectral matching. Matrix-matched samples and real samples were screened for proof of applicability. By manual review of data and application of ion ratio and ppm error criteria, false negatives were obtained; this number diminished when in-house library was used, while with on-line MS/MS databases 100% of positive samples were found. In our experience, intensity of peaks across spectra was highly correlated to the concentration effect and matrix complexity. In turn, analysis of spectra acquired at trace concentrations and in different matrices results in better performance in providing correct and reliable identification.
Collapse
|
11
|
Use of fish farms to assess river contamination: combining biomarker responses, active biomonitoring, and chemical analysis. AQUATIC TOXICOLOGY (AMSTERDAM, NETHERLANDS) 2013; 140-141:439-448. [PMID: 23928255 DOI: 10.1016/j.aquatox.2013.07.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2013] [Revised: 07/04/2013] [Accepted: 07/12/2013] [Indexed: 06/02/2023]
Abstract
Here we addressed the possible effects of trace levels of contaminants on fish by means of a combination of biomarker responses, active biomonitoring (ABM), and chemical analysis. In environmental studies, cytochromes P4501A (Cyp1A) and Cyp3A and related enzyme activities (7-ethoxyresorufin-O-deethylase, EROD, and benzyloxy-4-[trifluoromethyl]-coumarin-O-debenzyloxylase, BFCOD, respectively) are commonly used as biomarkers for evidencing exposure to a variety of contaminants. In a rainbow trout (Oncorhynchus mykiss) fish farm that is routinely sampled to obtain references regarding normal levels of such enzyme activities in freshwater fish, we observed a strong and punctual increase in these activities at the end of 2011. In order to shed light on the causes of this induction, we transferred some fish to a fish farm with controlled conditions and examined them using an active biomonitoring (ABM) approach. EROD activity showed a decrease of 80% from the original values after 7 days in the control farm, while BFCOD activity was also reduced after 15 days. Although not significant, a decrease in cyp1A and cyp3A mRNA levels was also observed. To determine the presence of pollutants, water and sediment samples from the river feeding the fish farm were analyzed by two-dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-TOF-MS). The screening study reflected a weak inflow of pollutants in the monitored area, which is located far from any industrial activity or densely populated cities. Trace levels of polyaromatic hydrocarbons (PAHs) and personal care products (the polycyclic musk fragrance HHCB, and triclosan) were detected in sediments, at concentrations ranging from 0.01 to 38 ng/g dry weight, and in water from 4 to 441 ng/L. The approach followed in this study proved useful as a biomonitoring technique for the early detection of trace contaminants.
Collapse
|
12
|
Investigation of Galaxolide degradation products generated under oxidative and irradiation processes by liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry and comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1237-1250. [PMID: 23650037 DOI: 10.1002/rcm.6575] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2012] [Revised: 03/15/2013] [Accepted: 03/17/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Polycyclic musks have become a concern due to their bioaccumulation potential and ecotoxicological effects. The HHCB transformation product (TP) (1,3,4,6,7,8-hexahydro-4,6,6,7,8,8-hexamethyl-cyclopenta[γ]-2-benzopyran; HHCB-lactone) is the most stable intermediate generated and it is frequently detected in river waters. The aim of this work was the identification of relevant TPs generated from UV irradiation and ozone treatments. METHODS Identification of HHCB TPs was carried out by liquid chromatography/hybrid quadrupole time-of-flight mass spectrometry (LC/ESI-QTOF-MS) and two-dimensional gas chromatography/electron impact time-of-flight mass spectrometry (GC×GC-EI-TOF-MS). With LC/ESI-QTOF-MS, TPs were characterized by means of mass accuracy in both full-scan and MS/MS modes through information-dependent acquisition (IDA) and direct injection on-column. With stir bar sorptive extraction (SBSE)-GC×GC-EI-TOF-MS, identification was based on the enhanced separation capacity and screening of unknowns through the acquisition of full-range mass spectra. RESULTS The effectiveness of these complementary techniques allowed a detailed evaluation of the main TPs. Eighteen TPs were elucidated based on mass accuracy, in both full-scan and MS/MS modes using LC/ESI-QTOF-MS with mass errors below 5 ppm and 10 ppm (mostly), respectively. Most of the TPs had not been analytically identified in previous studies. Separation of the enantiomeric species (R) and (S) of HHCB-lactone, and the identification of other relevant TPs, was performed using SBSE-GC×GC-EI-TOF-MS. CONCLUSIONS LC/ESI-QTOF-MS and GC×GC-EI-TOF-MS analysis provides the best alternative for TP identification of chemicals of concern, which have a wide range of polarities and isobaric compounds. A prediction of PBT (persistence, bioaccumulation and toxicity) using the PBT Profiler program suggested a classification of 'very persistent' and 'very toxic' for most of the TPs identified.
Collapse
|
13
|
Simultaneous measurement in mass and mass/mass mode for accurate qualitative and quantitative screening analysis of pharmaceuticals in river water. J Chromatogr A 2012; 1256:80-8. [PMID: 22901300 DOI: 10.1016/j.chroma.2012.07.038] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2012] [Revised: 06/19/2012] [Accepted: 07/15/2012] [Indexed: 10/28/2022]
Abstract
A new approach for the analysis of pharmaceuticals (target and non-target) in water by LC-QTOF-MS is described in this work. The study has been designed to assess the performance of the simultaneous quantitative screening of target compounds, and the qualitative analysis of non-target analytes, in just one run. The features of accurate mass full scan mass spectrometry together with high MS/MS spectral acquisition rates - by means of information dependent acquisition (IDA) - have demonstrated their potential application in this work. Applying this analytical strategy, an identification procedure is presented based on library searching for compounds which were not included a priori in the analytical method as target compounds, thus allowing their characterization by data processing of accurate mass measurements in MS and MS/MS mode. The non-target compounds identified in river water samples were ketorolac, trazodone, fluconazole, metformin and venlafaxine. Simultaneously, this strategy allowed for the identification of other compounds which were not included in the library by screening the highest intensity peaks detected in the samples and by analysis of the full scan TOF-MS, isotope pattern and MS/MS spectra - the example of loratadine (histaminergic) is described. The group of drugs of abuse selected as target compounds for evaluation included analgesics, opioids and psychostimulants. Satisfactory results regarding sensitivity and linearity of the developed method were obtained. Limits of detection for the selected target compounds were from 0.003 to 0.01 μg/L and 0.01 to 0.5 μg/L, in MS and MS/MS mode, respectively - by direct sample injection of 100 μL.
Collapse
|
14
|
Occurrence and persistence of organic emerging contaminants and priority pollutants in five sewage treatment plants of Spain: two years pilot survey monitoring. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2012; 164:267-73. [PMID: 22387188 DOI: 10.1016/j.envpol.2012.01.038] [Citation(s) in RCA: 248] [Impact Index Per Article: 20.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2011] [Revised: 01/18/2012] [Accepted: 01/22/2012] [Indexed: 05/11/2023]
Abstract
This work summarized all results obtained during almost two-years of a monitoring programme carried out in five municipal sewage treatment plants (STPs) located in the north, centre and south-east of Spain. The study evaluated the occurrence and persistence of a group of 100 organic compounds belonging to several chemical groups (pharmaceuticals, personal care products, pesticides and metabolites). The average removal efficiencies of the STPs studied varied from 20% (erythromycin) to 99% (acetaminophen). In analysed samples, we identified a large number of compounds at mean range concentrations between 7-59,495 ng/L and 5-32,720 ng/L for influent and effluent samples, respectively. This study also identified 20 of the mostly detected and persistent compounds in wastewater effluent, of which hydrochlorothiazide, atenolol, gemfibrozil, galaxolide and three metabolites (fenofibric acid, 4-AAA and 4-FAA), presented the highest average contribution percentages, in relation to the total load of contaminants for the different STPs effluent studied.
Collapse
|
15
|
Evaluation of selected ubiquitous contaminants in the aquatic environment and their transformation products. A pilot study of their removal from a sewage treatment plant. WATER RESEARCH 2011; 45:2331-41. [PMID: 21333319 DOI: 10.1016/j.watres.2011.01.011] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2010] [Revised: 01/10/2011] [Accepted: 01/13/2011] [Indexed: 05/15/2023]
Abstract
A simple method using direct sample injection combined with liquid chromatography tandem mass spectrometry has been developed for the simultaneous analysis of six alkaloid compounds in environmental samples. The target list includes two psychostimulants (nicotine and caffeine), three metabolites (cotinine, nicotinic acid and paraxanthine) and a coffee chemical (trigonelline). The analytical method was evaluated in three different matrices (surface water, influent and effluent wastewater). The method developed showed an adequate sensitivity, below 0.6 μg L(-1) for wastewater and 0.1 μg L(-1) for river matrices, without any prior treatment of the samples. Finally, the methodology was applied to real samples for evaluation of their removal from a sewage treatment plant and their persistence/fate in the aquatic environment. All compounds studied in this work were detected at all sampling points collected along the Henares River. However, nicotinic acid was only detected three times in treated sewage samples at levels above its detection limit.
Collapse
|
16
|
|
17
|
Removal of pharmaceuticals and kinetics of mineralization by O(3)/H(2)O(2) in a biotreated municipal wastewater. WATER RESEARCH 2008; 42:3719-3728. [PMID: 18657843 DOI: 10.1016/j.watres.2008.06.008] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2008] [Revised: 06/03/2008] [Accepted: 06/06/2008] [Indexed: 05/26/2023]
Abstract
The ozonation of an effluent from the secondary clarifier of two Municipal Wastewater Treatment Plants was performed by using alkaline ozone and a combination of ozone and hydrogen peroxide. Alkaline ozonation achieved only a moderate degree of mineralization, essentially concentrated during the first few minutes; but the addition of hydrogen peroxide eventually led to a complete mineralization. The evolution of total organic carbon (TOC) as a measure of the extent of mineralization and the concentration of dissolved ozone were analyzed and linked in a kinetic model whose parameter represented the product of the exposure to hydroxyl radicals and the kinetic constant of indirect ozonation. This rate parameter yielded the highest values during the first part of O(3)/H(2)O(2) runs. The kinetic constant for the decomposition of ozone at the end of the run was also measured and computed for the non-oxidizable water matrix and yielded essentially the same values regardless of whether or not hydrogen peroxide was used. A group of 33 organic compounds, mainly pharmaceuticals and some relevant metabolites present in the wastewater effluents, were evaluated before and after the ozonation process using a liquid chromatography-hybrid triple-quadrupole linear ion trap system (LC-QqLIT-MS). The results demonstrate that the ozonation degrades these compounds with efficiencies of over 99% in most cases, even under low mineralization conditions in alkaline ozonation.
Collapse
|
18
|
Photodegradation of malachite green under natural sunlight irradiation: kinetic and toxicity of the transformation products. CHEMOSPHERE 2008; 70:2068-2075. [PMID: 17959225 DOI: 10.1016/j.chemosphere.2007.09.008] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2007] [Revised: 09/04/2007] [Accepted: 09/05/2007] [Indexed: 05/25/2023]
Abstract
This article describes the photolytic degradation of malachite green (MG), a cationic triphenylmethane dye used worldwide as a fungicide and antiseptic in the aquaculture industry. Photolysis experiments were performed by direct exposure of a solution of MG in water to natural sunlight. The main transformation products (TPs) generated during the process were identified by liquid chromatography time-of-flight mass spectrometry (LC-TOF-MS) and gas chromatography mass spectrometry (GC-MS). The 28 TPs identified with this strategy indicate that MG undergoes three main reactions, N-demethylation, hydroxylation and cleavage of the conjugated structure forming benzophenone derivatives. These processes involve hydroxyl radical attack on the phenyl ring, the N,N-dimethylamine group and the central carbon atom. The Vibrio fischeri acute toxicity test showed that the solution remains toxic after MG has completely disappeared. This toxicity could be assigned, at least in part, to the formation of 4-(dimethylamine)benzophenone, which has an EC(50,30 min) of 0.061 mg l(-1), and is considered "very toxic to aquatic organisms" by current EU legislation.
Collapse
|
19
|
Evaluation of ozone-based treatment processes for wastewater containing microcontaminants using LC-QTRAP-MS and LC-TOF/MS. WATER SCIENCE AND TECHNOLOGY : A JOURNAL OF THE INTERNATIONAL ASSOCIATION ON WATER POLLUTION RESEARCH 2008; 57:41-48. [PMID: 18192739 DOI: 10.2166/wst.2008.809] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of a selected group of 57 organic contaminants in wastewater. This group comprises 39 pharmaceuticals belonging to different therapeutical classes and 10 of their most frequent metabolites. Six pesticides and two disinfectants were also included. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (Q TRAP) analyzer operating in selected reaction monitoring (SRM) mode (in both positive and negative electrospray ionization) in combination with a time-of flight (TOF) mass analyser. The application of both techniques provided very good results in terms of accurate quantification and unequivocal identification. Quantification was based on the use of a linearly accelerating (LINAC) high-pressure collision cell, which enable the analysis of a high number of compounds with enough acquisition data points for an optimal peak definition in SRM. Unequivocal identification was provided by the acquisition of at least two SRM transitions and by obtaining accurate mass measurements of the identified compounds with errors lower than 2 ppm. As an alternative for compounds where a second transition cannot be detected by Q-Trap-MS, the application of survey scans in enhanced product ion (EPI) was evaluated. The analytical performance of the method was evaluated in effluent wastewater samples. Linearity of response over three orders of magnitude was demonstrated (R2>0.99 for most compounds). Matrix effects resulting in suppression of the response were frequently observed, between 2-50% for most of compounds, except 4-DAA and 4-AA, which exhibit higher values (68%). Signal enhancement was also detected in 16 compounds. Method limits of detection (LOD) were between 0.1-50 ng L(-1). Finally, the methodology was successfully applied to the evaluation of the efficiency of two ozone-based treatments applied to the effluent from the secondary clarifier of a municipal wastewater treatment facility. Preliminary results are presented demonstrating that ozonation of wastewaters degrade pharmaceuticals with a high efficiency. Removals higher than 90% were reached for most of target analytes.
Collapse
|
20
|
Comprehensive screening of target, non-target and unknown pesticides in food by LC-TOF-MS. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2007.06.006] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
21
|
Large scale pesticide multiresidue methods in food combining liquid chromatography--time-of-flight mass spectrometry and tandem mass spectrometry. Anal Chem 2007; 79:7308-23. [PMID: 17718536 DOI: 10.1021/ac070855v] [Citation(s) in RCA: 99] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Liquid chromatography tandem mass spectrometry (LC-MS/MS) and liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) are powerful and complementary techniques that can independently cover the majority of the challenges related with pesticide residue food control. The sequential combination of both systems benefits from their complementary advantages and assists to increase the performance and to simplify routine large scale pesticide multiresidue methods. The proposed approach consists of three stages: (1) automated pesticide screening by LC-TOFMS; (2) identification by LC-TOFMS accurate mass measurements; and (3) confirmation and quantitation by LC-MS/MS. We have developed a fast comprehensive (identification/confirmation + quantitation) automated screening method for 100 target pesticides in crops. In the first stage, a set of data including m/z accurate mass windows (within 20 mDa width) and retention time is obtained (using a standard solution containing all the targeted pesticides) in order to build the automated screening procedure, which is created automatically by assigning retention time and the m/z mass window for each target pesticide. Samples are then analyzed, and the method enables the screening and preliminary identification of the species first by retention time and m/z mass window, followed by subsequent identification (only if positive results) by LC-TOFMS accurate mass measurements. After that, final confirmation of the positive findings using two MRM transitions and accurate quantitation is performed by LC-MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) mass spectrometer. In addition, the use of this QqLIT instrument also offers additional advantageous scanning modes (enhanced product ion and MS3 modes) for confirmatory purposes in compounds with poor fragmentation. Examples of applications to real samples show the potential of the proposed approach, including the detection of nonselected "a priori" compounds as a typical case of retrospective evaluation of banned or misused substances.
Collapse
|
22
|
Application of high-performance liquid chromatography–tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil. Anal Bioanal Chem 2007; 389:1815-31. [PMID: 17713761 DOI: 10.1007/s00216-007-1464-z] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2007] [Revised: 06/18/2007] [Accepted: 06/21/2007] [Indexed: 11/30/2022]
Abstract
This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of pesticides in olive oil. One hundred pesticides belonging to different classes and that are currently used in agriculture have been included in this method. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (QqQ(LIT)) analyzer. Key features of this technique are the rapid scan acquisition times, high specificity and high sensitivity it enables when the multiple reaction monitoring (MRM) mode or the linear ion-trap operational mode is employed. The application of 5 ms dwell times using a linearly accelerating (LINAC) high-pressure collision cell enabled the analysis of a high number of pesticides, with enough data points acquired for optimal peak definition in MRM operation mode and for satisfactory quantitative determinations to be made. The method quantifies over a linear dynamic range of LOQs (0.03-10 microg kg(-1)) up to 500 microg kg(-1). Matrix effects were evaluated by comparing the slopes of matrix-matched and solvent-based calibration curves. Weak suppression or enhancement of signals was observed (<15% for most-80-of the pesticides). A study to assess the identification criteria based on the MRM ratio was carried out by comparing the variations observed in standard vs matrix (in terms of coefficient of variation, CV%) and within the linear range of concentrations studied. The CV was lower than 15% when the response observed in solvent was compared to that in olive oil. The limit of detection was < or =10 microg kg(-1) for five of the selected pesticides, < or =5 microg kg(-1) for 14, and < or =1 microg kg(-1) for 81 pesticides. For pesticides where additional structural information was necessary for confirmatory purposes-in particular at low concentrations, since the second transition could not be detected-survey scans for enhanced product ion (EPI) and MS3 were developed.
Collapse
|
23
|
LC-MS analysis of basic pharmaceuticals (beta-blockers and anti-ulcer agents) in wastewater and surface water. Trends Analyt Chem 2007. [DOI: 10.1016/j.trac.2007.03.005] [Citation(s) in RCA: 89] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Toxicity evaluation with Vibrio fischeri test of organic chemicals used in aquaculture. CHEMOSPHERE 2007; 68:724-30. [PMID: 17292447 DOI: 10.1016/j.chemosphere.2006.12.097] [Citation(s) in RCA: 96] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2006] [Revised: 11/08/2006] [Accepted: 12/31/2006] [Indexed: 05/09/2023]
Abstract
The evaluation of acute toxicity by Vibrio fischeri test for different organic chemicals (antibiotics, pesticides, therapeutants, herbicides) commonly applied in aquaculture and a degradation product of surfactants, 4-nonylphenol, is presented in this work. Simazine, atrazine, emamectin benzoate and leucomalachite green have no toxic effects on V. fischeri at the concentration tested (up to 6mgl(-1)) which correspond to the maximum water solubility. Ciprofloxacin, terbutryn and deltamethrin, caused inhibition effects of 28%, 22% and 30% at concentrations up to 5mgl(-1). Toxic effects were not observed in the case of flumequine and oxolinic acid at the maximum concentration tested (0.189mgl(-1)). According to the toxicity categories established in the EU legislation, ciprofloxacin, terbutryn and deltamethrin could be considered non-harmful for V. fischeri. Malachite green and 4-nonylphenol are "very toxic to aquatic organisms" (EC(50,30min)=0.031mgl(-1) and 0.48mgl(-1), respectively). Carbaryl is "toxic to aquatic organisms" (2.4mgl(-1)). and glyphosate is harmful to V. fischeri (EC(50,30min)=44.2mgl(-1)). The matrix effect was evaluated comparing the toxicity measurements of the target compounds solubilized in seawater and distilled water. Malachite green, 4-nonylphenol and glyphosate, showed higher toxicity in distilled water than in seawater. Carbaryl was more toxic in seawater. All the compounds tested in seawater were not harmful at concentrations of ngl(-1) (10 and 50). However, 4-nonlylphenol and malachite green may act as toxic compounds in the environment at a low ppb level, since both may be detected in water at this concentration level.
Collapse
|
25
|
Fast separation liquid chromatography-tandem mass spectrometry for the confirmation and quantitative analysis of avermectin residues in food. J Chromatogr A 2007; 1155:62-73. [PMID: 17524410 DOI: 10.1016/j.chroma.2007.02.120] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2006] [Revised: 01/26/2007] [Accepted: 02/05/2007] [Indexed: 10/23/2022]
Abstract
A new residue analytical method for the confirmation and quantification of avermectin residues in food is described in this article. This method allows a fast analysis for the determination of avermectin residues, abamectin (ABM), ivermectin (IVM), emamectin benzoate (EMA) and doramectin (DOR) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Separation was performed using a short column of 1.8 microm particle size. The hybrid quadrupole/linear ion trap (QqQ(LIT)) system via the linearly accelerating (LINAC) high-pressure collision cell, allows the MS detection in multiple reaction monitoring (MRM) mode operating in fast scan acquisition times. The effect of reduced dwell times on mass spectral quality and sensitivity is evaluated in this study. For quantitative purposes, the influence of dwell time on S/N ratio and peak area was observed. ABM, IVM, EMA and DOR show an increased trend of peak area and S/N ratio, when dwell times are of 50 ms against 10-20 ms, suited when the number of compounds to be analyzed is higher. The sensitivity achieved by using the LC-MS/MS system is enough for the confirmation of avermectin residues in the selected commodities (salmon muscle and pepper) at trace concentration levels (sub-microg/kg and microg/kg) and therefore a sample pre-concentration step was not necessary. The instrumental limits of quantification (ILQ) are in the range of 0.15-5 ppb. Samples were extracted by solid-liquid extraction (SLE) procedure using acetonitrile, and cleaned-up using alumina. The average recoveries obtained were acceptable (80-95%). The calibration curves were linear over the working range from ILQs to 500 microg/kg. For the quantitative analysis, matrix-matched calibration and dilution of SLE extracts was proven as reliable alternative to compensate matrix-effects and for its feasible application in routine analysis.
Collapse
|
26
|
Photolysis and photocatalysis of bisphenol A: identification of degradation products by liquid chromatography with electrospray ionization/time-of-flight/mass spectrometry (LC/ESI/ToF/MS). ACTA ACUST UNITED AC 2006; 23:1242-51. [PMID: 17071528 DOI: 10.1080/02652030600889541] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Bisphenol A is a commonly known endocrine-disrupting compound detected in environmental water samples. The persistence of this compound has been studied by photolysis and photocatalysis studies. In this work, several experiments were performed in order to identify the degradation products under various conditions and in different types of matrices (deionized and waste water). These studies included the influence of sodium hypochlorite (NaClO), commonly present in drinking water, on the generation of chlorine by-products of bisphenol A. The effect of catalyses in solar degradation studies was evaluated as well. The identification of the degradation products was accomplished by liquid chromatography/time-of-flight/mass spectrometry (LC-ToF-MS), which provided highly selective information about elemental compositions. Accurate mass measurements for three main degradation products permitted the postulation of proposed empirical formula in this study. Some of the degradation products were formed in waste water matrices, thus suggesting their potential presence in environmental conditions and in drinking water.
Collapse
|
27
|
LC-MS analysis and environmental risk of lipid regulators. Anal Bioanal Chem 2006; 387:1269-85. [PMID: 17047939 DOI: 10.1007/s00216-006-0781-y] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2006] [Revised: 08/01/2006] [Accepted: 08/15/2006] [Indexed: 10/24/2022]
Abstract
This article presents a review of liquid chromatography-mass spectrometric (LC-MS) methods applied to the determination of lipid-regulating agents, "fibrate" and "statin" classes, and some of their metabolites (clofibric acid and fenofibric acid) in environmental samples. Concentration levels of this therapeutical group have been reported in the ppt to ppb range for different compartments (wastewater, surface water and sediments) in several monitoring studies. Part of this article is dedicated to hazard assessment of lipid-regulating agents according to the approaches of the European Union (EU) and Environmental Protection Agency (EPA) for identifying persistent, bioaccumulable and toxic (PBT) substances. The pharmacodynamic and pharmacokinetic activities of these pharmaceuticals are well known and, based on this information, the derivation of the potential long-term effects, which may be induced on eco-organisms at low concentration levels, is discussed. Studies of environmental risk assessment (ERA) for lipid regulators carried out through the framework of the European Agency for the Evaluation of Medicinal Products (EMEA) and Food and Drug Administration (FDA) are presented.
Collapse
|
28
|
Trace-level determination of pharmaceutical residues by LC-MS/MS in natural and treated waters. A pilot-survey study. Anal Bioanal Chem 2006; 385:985-91. [PMID: 16568292 DOI: 10.1007/s00216-006-0394-5] [Citation(s) in RCA: 87] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2005] [Revised: 02/17/2006] [Accepted: 02/21/2006] [Indexed: 10/24/2022]
Abstract
A pilot-survey study was performed by collecting samples (influent and effluent wastewaters, rivers and tap waters) from different locations in Europe (Spain, Belgium, Germany and Slovenia). A solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry method was applied for the determination of pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac and clofibric acid). Method detection limits and method quantification limits were at the parts-per-trillion level (7.5-75 ng/L). The recovery rates of the SPE from deionized water and effluent wastewater samples spiked at 100- and 1,000-ng/L levels ranged from 87 to 95%. Identification criteria in compliance with the EU regulation for confirmatory methods of organic residues were applied. A detailed study of signal suppression evaluation for analysis of pharmaceutical residues in effluent wastewaters is presented.
Collapse
|
29
|
Analysis by liquid chromatography-electrospray ionization tandem mass spectrometry and acute toxicity evaluation for beta-blockers and lipid-regulating agents in wastewater samples. J Chromatogr A 2004; 1046:133-40. [PMID: 15387181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
This paper describes a multiresidue method for the extraction and determination of two therapeutic groups of pharmaceuticals, lipid-regulating agents (clofibric acid, bezafibrate, gemfibrocil, fenofibrate) and beta-blockers (atenolol, sotalol, metoprolol, betaxolol) in waters by solid-phase extraction followed by liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS). Recoveries obtained from spiked HPLC water, as well as, from spiked real samples (sewage treatment plants influent and effluents, river and tap water) were all above 60%, with the exception of betaxolol with a 52% recovery. The quantitative MS analysis was performed using a multiple reaction monitoring. The LC-MS-MS method gave detection limits ranging from 0.017 to 1.25 microg/l in spiked effluent. Precision of the method, calculated as relative standard deviation, ranged from 3.7 to 18.5%. Individual and combined effects on Daphnia magna were evaluated for both therapeutic groups. Individual effects in culture medium showed these compounds as not harmful and not toxic, an exception is fenofibrate that was found to be harmful, but at high, in the environment unrealistic concentrations (EC50 of 50 mg/l). Combined effect in wastewater showed synergistic toxic effects at low concentration level (2 microg/l).
Collapse
|
30
|
Comparative study of analytical methods involving gas chromatography–mass spectrometry after derivatization and gas chromatography–tandem mass spectrometry for the determination of selected endocrine disrupting compounds in wastewaters. J Chromatogr A 2004; 1047:129-35. [PMID: 15481468 DOI: 10.1016/j.chroma.2004.06.123] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Two GC-MS methods, based on the application of N,O-bis(trimethylsilyl)trifluoroacetamide-derivatization-GC-MS (selected-ion monitoring) and GC-MS-MS without derivatization, respectively, were optimised and applied to the determination of a group of five selected endocrine disrupting compounds (EDCs) in wastewaters. Both methods included solid-phase extraction with Oasis HLB cartridges allowing an enrichment factor for wastewater samples of 100-fold. The investigated EDCs were estrone, 17beta-estradiol, 17alpha-ethynylestradiol, 4-tert-octylphenol and bisphenol A. Results obtained from the validation studies yielded comparable results in both cases. Recoveries in spiked wastewaters at 50 ng/l were higher than 90% for all the compounds, except for 4-tert-octylphenol (75%). Repeatability and reproducibility were adequate, varying from 1.6 to 14%, except for estrone which reproducibility was 28% when the derivatization-GC-MS method was applied. Limits of detection calculated ranged from 2.5 to 27.5 ng/l with differences between both methods from 1.1 (estrone) to 10.4 (bisphenol A) times. Both methods were successfully applied to the analysis of the target compounds in sewage treatment plant influents and effluents. Traces of bisphenol A, 4-tert-octylphenol, estrone and 17beta-estradiol were detected at concentration levels ranging from 13.3 to 1105.2 ng/l.
Collapse
|
31
|
Liquid chromatography/time-of-flight mass spectrometric analyses for the elucidation of the photodegradation products of triclosan in wastewater samples. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:443-450. [PMID: 14966851 DOI: 10.1002/rcm.1351] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Liquid chromatography coupled with time-of-flight mass spectrometry (LC/TOFMS) was applied for the identification of four new photodegradation products of triclosan, a major antimicrobial agent used in personal care products. Wastewater samples, spiked at 7 microg/mL with triclosan, were irradiated with natural sunlight in order to generate the photodegradation products. Aliquots of the spiked water samples were taken at different times of irradiation and compounds were isolated from the water samples by solid-phase extraction. Separation and detection of the compounds and degradation products were accomplished by LC/TOFMS, which provided highly selective information about elemental compositions. Accurate mass measurements for the four degradation products permitted postulation of proposed empirical formulae in this study. Replacement of chlorine atoms by hydroxyl groups and chlorine losses are the major degradation pathways proposed. The degradation products were formed also under environmental conditions in wastewater matrices, thus suggesting their presence in real wastewater treatment processes.
Collapse
|
32
|
Combined toxicity effects of MTBE and pesticides measured with Vibrio fischeri and Daphnia magna bioassays. WATER RESEARCH 2003; 37:4091-4098. [PMID: 12946890 DOI: 10.1016/s0043-1354(03)00348-8] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Methyl-tert-butyl ether (MTBE), a fuel oxygenate that is added to gasoline, commonly contaminates aquatic systems, many of which are already contaminated with pesticides. The toxic effects (EC(50) value) of several pure pesticides (Diuron, Linuron, Dichlofluanid, Sea nine, Irgarol and tributyltin (TBT)) were measured and compared with the EC(50) value of the pesticide mixed with MTBE, using the Vibrio fischeri and Daphnia magna acute toxicity assays. The interaction between chemicals was evaluated in terms of the effects of mixing on the EC(50) value (i.e. the concentration (mg/L) of a compound or mixture that is required to produce a 50% change in a toxic response parameter) and the time required to generate the toxic response. Presence of MTBE enhanced the EC(50) value of several pesticides (Diuron, Dichlofluanid, TBT and Linuron) and/or the toxic response manifested more rapidly than with pure pesticides. Toxicity enhancements were quite substantial in many cases. For example, the presence of MTBE increased the toxicity of Diuron by more than 50% when tested with the V. fischeri assay (5, 15 and 30 min exposure). Also, the toxic response manifested itself within 5 min whereas without the MTBE the same response arose in 30 min. Presence of MTBE increased the toxicity of Dichlofluanid by 30% when measured with the D. magna assay. Toxicities of only two pesticides (Sea nine and Irgarol) were not raised by the presence of MTBE.
Collapse
|
33
|
Photocatalytic treatment of diuron by solar photocatalysis: evaluation of main intermediates and toxicity. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2003; 37:2516-2524. [PMID: 12831038 DOI: 10.1021/es0261170] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The technical feasibility, mechanisms, and performance of degradation of aqueous diuron (22 mg/L) have been studied at pilot scale in two well-defined photocatalytic systems of special interest because natural UV light can be used: heterogeneous photocatalysis with titanium dioxide and homogeneous photocatalysis by photo-Fenton. Equivalent pilot-scale (made up of Compound Parabolic Collectors (CPCs) specially designed for solar photocatalytic applications) and field conditions used for both allowed adequate comparison of the degree of mineralization and toxicity achieved as well as the transformation products generated en route to mineralization by both systems. Total disappearance of diuron is attained by both phototreatments in 45 min. 100% of chlorine was recovered as chloride, but total recovery of nitrogen as inorganic ions was not attained. 90% of mineralization was reached after 200 min of photocatalytic treatment, but toxicity measured by two different bioassays (Daphnia magna and a Microalga) was reduced to below the threshold (EC50%) in a shorter time. Transformation products evaluated by LC-IT-MS by direct injection of the samples were the same in both cases. The main differences between the two processes were in the amount of transformation products (DPs) generated, not in the DPs detected, which were always the same.
Collapse
|
34
|
Abstract
Different types of organic pollutants commonly detected in seawater have been evaluated by acute toxicity bioassays. Vibrio fischeri, Daphnia magna, and Selenastrum capricornotum were selected to test toxic effects of individual compounds and mixtures of these compounds, obtaining EC50 values in the range of 0.001 to 28.9 mg/l. In the case of mixtures, synergistic toxic responses were seen for a clear majority of the cases (>60%). Mixtures containing methyl-tertiary-butyl ether (MTBE) exhibit accelerated processes that result in a change in concentration required to produce a toxic effect; for example, in the case of mixtures containing MTBE and Diuron and Dichlofluanid.
Collapse
|
35
|
Determination of traces of five antifouling agents in water by gas chromatography with positive/negative chemical ionisation and tandem mass spectrometric detection. J Chromatogr A 2001; 938:103-11. [PMID: 11771828 DOI: 10.1016/s0021-9673(01)01201-8] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
A highly selective and sensitive gas chromatography-mass spectrometry methodology has been developed for the determination of five antifouling compounds, currently licensed for use in marine antifouling paints. The procedure uses an ion trap mass spectrometer provided with an external ion source that allows the combined use, in the same analysis, of positive (PCI) and negative (NCI) chemical ionisation and tandem mass spectrometric fragmentation (MS-MS). Ionisation and fragmentation processes were optimised individually for each compound, thus, permitting maximum sensitivity and selectivity to be obtained. A complete validation study, including those aspects that affect both correct quantification and unequivocal confirmation, demonstrated the good performance of the proposed method. Detection limits obtained were lower than 0.005 microg l(-1), except for Irgarol 1051 (0.050 microg l(-1)). The method was applied to real seawater samples from different
Collapse
|
36
|
Occurrence of antifouling biocides in the Spanish Mediterranean marine environment. ENVIRONMENTAL TECHNOLOGY 2001; 22:543-552. [PMID: 11424731 DOI: 10.1080/09593332208618258] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
A compilation of the results of a monitoring program of the recently used antifouling pesticides diuron (3-(3,4-dichlorophenyl)-1,1-dimethylurea), Irgarol 1051 (2-methylthio-4-tertiary-butylamino-6-cyclopropylamino-s-teiazine), seanine 211 (4,5-dichloro-2-n-octyl-4-isothazolin-3-one), chlorothalonil (2,4,5,6-tetrachloro-isophthalonitrile), dichlofluanid (N'-dimethyl-N-phenylsulphanamide), TCMTB ((2-thiocyanomethylthio) benzothiazole), and three degradation products demethyldiuron (3-(3,4-dichlorophenyl)-1-methylurea),3,4-dichlorophenylurea and 2-methylthio-4-tert-butylamino-s-triazine (Irgarol degradation product) that was carried out between April 1996 and February 2000 in enclosed seawaters from Catalonia and Almería (Spanish Mediterranean coast) is reported. Nine points were sampled along the Catalan coast: Barcelona Olympic port, Masnou, Blanes, Sant Carles de la Ràpita, Tarragona, Cambrils and Salou marinas as well as the Cambrils and Tarragona fishing harbors and in marinas and ports from Almeria: Aguadulce port, Almería port, Almerimar fishing harbour and Almerimar marina. The analytical methodologies were based on Solid Phase Extraction followed by liquid chromatography (LC) or gas chromatography (GC) coupled to a mass spectrometry (MS) or -Diode Array Detector. The main pollutants found in the sampled points were diuron and Irgarol 1051 that were detected at concentrations up to 2.19 micrograms l-1 and 0.33 microgram l-1, respectively. On the other hand, seanine 211 was found at the highest concentration (up to 3.7 micrograms l-1) during the summer of 1999. Low concentrations of dichlofluanid and the above mentioned degradation products were detected for the first time in the Spanish coasts. Chlorothalonil, TCMTB were not found at concentrations higher than 1 and 20 ng l-1 respectively which were the limit of determination (LOD) of the method for these compounds. In general the contamination at the different marinas is higher at the end of spring and in summer where the boating activity is also higher. This paper shows for the first time that the contamination by the new antifouling pesticides in Spanish coastline, basically marinas and fishing harbours, is permanent along the whole calendar year. So, preventive actions by the harbour authorities will be needed in the near future in order to monitor and control the levels and effects of the new antifouling biocides in the marine environment.
Collapse
|
37
|
Gas chromatographic determination of pesticides in vegetable samples by sequential positive and negative chemical ionization and tandem mass spectrometric fragmentation using an ion trap analyser. Analyst 2001; 126:46-51. [PMID: 11205511 DOI: 10.1039/b006933g] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A selective and sensitive chromatographic method is described for the determination of nine organochlorine and organophosphorus pesticides in vegetable samples by gas chromatography-mass spectrometry. The proposed method combines the use of positive and negative chemical ionisation and tandem mass spectrometric fragmentation, resulting in a significant increase in selectivity and allowing the simultaneous confirmation and quantification of trace levels of pesticides in complex vegetable matrices. Parameters relative to ionisation and fragmentation processes were optimised to obtain maximum sensitivity. Repeatability and reproducibility studies yielded relative standard deviations lower than 25% in all cases. Identification criteria, such as retention time and relative abundance of characteristic product ions, were also evaluated in order to guarantee the correct identification of the target compounds. The method was applied to real vegetable samples to demonstrate its use in routine analysis.
Collapse
|
38
|
Multiresidue method for the analysis of five antifouling agents in marine and coastal waters by gas chromatography-mass spectrometry with large-volume injection. J Chromatogr A 2000; 889:261-9. [PMID: 10985557 DOI: 10.1016/s0021-9673(00)00425-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A simple multiresidue method has been developed for the determination of five pesticides, commonly used as active ingredients in antifouling paints, in seawater samples. The pesticides studied were: chlorothalonil (2,4,5,6-tetrachloroisophthalonitrile), dichlofluanid (N-dimethyl-N-phenylsulphamide), Sea-Nine 211 (4,5-dichloro-2-n-octyl-4-isothazolin-3-one), Irgarol 1051 (2-methylthio-4-tert.-butylamino-6-cyclopropylamino-s-triazine) and TCMTB (2-thiocyanomethylthiobenzothiazole). The analytes were extracted from 200 ml water samples, using solid-phase extraction. A copolymer with hydrophilic-lipophilic balance was used as sorbent yielding good recoveries (82-95%) for most compounds except dichlofluanid and Sea-Nine 211 (<60%). Large volume injection (10 microl) gas chromatography and electron impact ionization MS (selected ion monitoring mode) detection enabled these compounds to be identified and quantified at the 1.2-3.0 ng/l level. Analysis of samples performed in three marinas in Almería (Spain) revealed the presence of Irgarol 1051 in all the cases, at concentration levels between 25 and 450 ng/l.
Collapse
|
39
|
Splitless large-volume GC-MS injection for the analysis of organophosphorus and organochlorine pesticides in vegetables using a miniaturised ethyl acetate extraction. Analyst 2000; 125:1397-402. [PMID: 11002922 DOI: 10.1039/b002611p] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple, rapid and sensitive multiresidue method has been developed for the determination of ten organophosphorus and organochlorine pesticides, commonly used in crop protection. The analysis uses a miniaturised extraction with ethyl acetate followed by large volume injection (10 microL) GC-EI-MS analysis in SIM (selective ion monitoring) mode. Sensitivity and selectivity of the method were acceptable with limits of detection (LODs) lower than 0.01 mg kg-1, except for endosulfan alpha and beta (0.05 mg kg-1). Average recoveries of between 63-99% were obtained and good linearity was observed in the range from 0.01 to 1.00 mg kg-1. Repeatability and reproducibility studies yielded relative standard deviations lower than 20% in all the cases. The method was applied to the analysis of 110 tomato, pepper and cucumber samples, as part of the monitoring programme of the Association of Producers and Exporters of Fruits and Vegetables of Almería.
Collapse
|