26
|
Megaly M, Morcos R, Khalil C, Garcia S, Basir M, Maini B, Khalili H, Burke MN, Alaswad K, Brilakis ES. Complications and failure modes of coronary embolic protection devices: Insights from the MAUDE database. Catheter Cardiovasc Interv 2021; 99:405-410. [PMID: 33876860 DOI: 10.1002/ccd.29717] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 04/12/2021] [Indexed: 11/10/2022]
Abstract
BACKGROUND There is limited data on complications associated with the use of coronary embolic protection devices (EPDs). METHODS We queried the Manufacturer and User Facility Device Experience database between November 2010 and November 2020 for reports on coronary EPDs: Spider FX (Medtronic, Minneapolis, MN) and Filterwire EZ (Boston Scientific, Natick, MA). RESULTS We retrieved 119 reports on coronary EPD failure (Spider FX n = 33 and Filterwire EZ n = 86), most of which (78.2%) occurred during saphenous vein graft interventions. The most common failure mode was inability to retrieve the EPD (49.6%), with the filter trapped against stent struts in 76.2% of the cases. Other device complications included filter fracture (28.6%), failure to cross (7.6%), failure to deploy (7.6%), and failure to recapture the filter (3.4%). Filter fracture (54.5 vs. 29.1%) and failure to recapture (9.1 vs. 2.1%) were more commonly reported, while failure to deploy the filter (0 vs. 10.5%) was less commonly reported with the Spider-FX. CONCLUSIONS The most common modes of failure of coronary EPDs are the failure of retrieval (49.6%), followed by the filter fracture (28.6%). When using EPDs, careful attention to the technique is essential to avoid failures and subsequent complications.
Collapse
|
27
|
Lopera JE, Jen S. Superior vena cava filter placement over existing central venous lines: Is line removal necessary? Catheter Cardiovasc Interv 2020; 96:651-656. [PMID: 32383298 DOI: 10.1002/ccd.28953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2020] [Revised: 04/09/2020] [Accepted: 04/23/2020] [Indexed: 11/08/2022]
Abstract
OBJECTIVES To evaluate the technical feasibility and clinical safety of superior vena cava (SVC) filter placement over preexisting central venous lines (CVLs) in 23 patients who had upper extremity deep venous thrombosis with contraindications to anticoagulation. METHODS A retrospective review of the images and electronic medical records of 23 patients from 2008 to 2018 with SVC filters placed over an existing central venous line was performed in a single tertiary medical center. Twenty-one filters were placed over smaller lines (<8 Fr), and two were placed over hemodialysis catheters. Venograms before and after filter placement were compared to detect any evidence of line displacement or entrapment. Medical records were reviewed to determine whether there was any difficulty during line removal. RESULTS In two of five patients with dual lines, significant line displacement was noted in the left-sided lines, both lines were later removed without complications. In one patient with a hemodialysis catheter, the filter was deployed over the tip of the catheter resulting in the entrapment of one of the legs of the filter within a side hole of the line. Fourteen patients had their lines later removed 3 days to 3 months after filter placement without reported problems. Nine patients had their CVLs left in place until the patient's death or discharge to a long-term facility. CONCLUSIONS SVC filter placement over preexisting CVLs seems to be technically feasible and clinically safe in patients with <8-Fr CVLs. However, placement of the filters over hemodialysis catheters can result in leg entrapment.
Collapse
|
28
|
Fink JB, Ehrmann S, Li J, Dailey P, McKiernan P, Darquenne C, Martin AR, Rothen-Rutishauser B, Kuehl PJ, Häussermann S, MacLoughlin R, Smaldone GC, Muellinger B, Corcoran TE, Dhand R. Reducing Aerosol-Related Risk of Transmission in the Era of COVID-19: An Interim Guidance Endorsed by the International Society of Aerosols in Medicine. J Aerosol Med Pulm Drug Deliv 2020; 33:300-304. [PMID: 32783675 PMCID: PMC7757542 DOI: 10.1089/jamp.2020.1615] [Citation(s) in RCA: 67] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
National and international guidelines recommend droplet/airborne transmission and contact precautions for those caring for coronavirus disease 2019 (COVID-19) patients in ambulatory and acute care settings. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus, an acute respiratory infectious agent, is primarily transmitted between people through respiratory droplets and contact routes. A recognized key to transmission of COVID-19, and droplet infections generally, is the dispersion of bioaerosols from the patient. Increased risk of transmission has been associated with aerosol generating procedures that include endotracheal intubation, bronchoscopy, open suctioning, administration of nebulized treatment, manual ventilation before intubation, turning the patient to the prone position, disconnecting the patient from the ventilator, noninvasive positive-pressure ventilation, tracheostomy, and cardiopulmonary resuscitation. The knowledge that COVID-19 subjects can be asymptomatic and still shed virus, producing infectious droplets during breathing, suggests that health care workers (HCWs) should assume every patient is potentially infectious during this pandemic. Taking actions to reduce risk of transmission to HCWs is, therefore, a vital consideration for safe delivery of all medical aerosols. Guidelines for use of personal protective equipment (glove, gowns, masks, shield, and/or powered air purifying respiratory) during high-risk procedures are essential and should be considered for use with lower risk procedures such as administration of uncontaminated medical aerosols. Bioaerosols generated by infected patients are a major source of transmission for SARS CoV-2, and other infectious agents. In contrast, therapeutic aerosols do not add to the risk of disease transmission unless contaminated by patients or HCWs.
Collapse
|
29
|
Hong J, Tan B, Quang ND, Gupta P, Lin E, Wong D, Ang M, Lamoureux E, Schmetterer L, Chua J. Intra-session repeatability of quantitative metrics using widefield optical coherence tomography angiography (OCTA) in elderly subjects. Acta Ophthalmol 2020; 98:e570-e578. [PMID: 31833241 PMCID: PMC7496426 DOI: 10.1111/aos.14327] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 11/17/2019] [Indexed: 01/14/2023]
Abstract
PURPOSE To assess the repeatability of retinal vascular metrics using different postprocessing methods as obtained from the swept-source optical coherence tomography angiography (SS-OCTA). METHODS Thirty-two participants (63% males; mean [SD] age, 70 [7] years) underwent SS-OCTA imaging (PLEX® Elite 9000, Carl Zeiss Meditec, Inc., Dublin, USA). Each participant underwent 2 repeated scans of 2 scan protocols: a macular-centred 3 × 3-mm2 and a widefield 12 × 12-mm2 for a total of 4 acquisitions. Images of superficial vascular plexuses (SVP) and deep vascular plexuses (DVP) were processed using different filters to generate the perfusion density (PD) and vessel density (VD). Vessel enhancement filters ranged from vessel targeted (Hessian and Gabor filters), classical denoising (Gaussian filter), to a scale-selective adaption (modified Bayesian residual transform [MBRT]). Intra-session repeatability of the different filters and their correlation with the original data set were calculated with the intraclass correlation coefficient (ICC) and Pearson's r. RESULTS Of the 32 eyes, 17 and 15 were right and left eyes, respectively. For 3 × 3-mm2 scans, both MBRT and Gabor filters yielded very good repeatable PD and VD (both ICCs > 0.87) values. Gabor filter was the most correlated with the original data set for the OCTA metrics (r = 0.95-0.97). For 12 × 12-mm2 scans, MBRT filter produced good-to-moderate ICC values for SVP (ICC>0.89) and DVP (ICC>0.73) metrics. Both the MBRT and Gabor filters were highly correlated with the original 12 × 12-mm2 scan data set (r = 0.96-0.98). The ICCs for the agreement between 3 × 3-mm2 and cropped 12 × 12-mm2 were high only for the PD values at the SVP layer and were poor for the VD at SVP and DVP measurements (ICC < 0.50). CONCLUSION Our findings show that with the proper choice of postimaging processing methods, SS-OCTA metrics can be obtained with high repeatability, which supports its use in various clinical settings.
Collapse
|
30
|
Water Sorption by Different Types of Filter Media Used for Particulate Matter Collection Under Varying Temperature and Humidity Conditions. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17145180. [PMID: 32709113 PMCID: PMC7400541 DOI: 10.3390/ijerph17145180] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 07/13/2020] [Accepted: 07/15/2020] [Indexed: 01/08/2023]
Abstract
The present study describes the effects of temperature and humidity on the level of water absorption by filter blanks most popularly used for gravimetric analyzes of particulate matter (PM) and the effects of those on the accuracy of its weight measurements. The main parts of the research quantified the effect of temperature and humidity conditions on water contents quartz fiber (Q), fiberglass (G), PTFE, and nylon (N) filters. Supplementary studies were conducted to estimate the effects of temperature, humidity and material on mass loss/gain and the shape of water retention. All chemical analyses of water contents were performed by the Karl Fischer titration method. The results indicate that quartz filters are the most susceptible to the variations in water contents under changing humidity levels and therefore, less suitable to high accuracy determinations of PM mass compared to nylon or glass filters; PTFE performed the best due to their hydrophobicity. For PM water contents determinations, the best choice of filter media is PTFE. Although many other factors determine the choice of filter type for PM analyses, the present study is an important contribution to knowledge of assessing the suitability of different types of filter material for specific measurements.
Collapse
|
31
|
Abstract
Aim: The explosion of data based technology has accelerated pattern mining. However, it is clear that quality and bias of data impacts all machine learning and modeling. Results & methodology: A technique is presented for using the distribution of first significant digits of medicinal chemistry features: logP, logS, and pKa. experimental and predicted, to assess their following of Benford's law as seen in many natural phenomena. Conclusion: Quality of data depends on the dataset sizes, diversity, and magnitudes. Profiling based on drugs may be too small or narrow; using larger sets of experimentally determined or predicted values recovers the distribution seen in other natural phenomena. This technique may be used to improve profiling, machine learning, large dataset assessment and other data based methods for better (automated) data generation and designing compounds.
Collapse
|
32
|
Young IR, Szeverenyi NM, Du J, Bydder GM. Pulse sequences as tissue property filters (TP-filters): a way of understanding the signal, contrast and weighting of magnetic resonance images. Quant Imaging Med Surg 2020; 10:1080-1120. [PMID: 32489930 PMCID: PMC7242304 DOI: 10.21037/qims.2020.04.07] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Accepted: 03/23/2020] [Indexed: 02/04/2023]
Abstract
This paper describes a quantitative approach to understanding the signal, contrast and weighting of magnetic resonance (MR) images. It uses the concept of pulse sequences as tissue property (TP) filters and models the signal, contrast and weighting of sequences using either a single TP-filter (univariate model) or several TP-filters (the multivariate model). For the spin echo (SE) sequence using the Bloch equations, voxel signal intensity is plotted against the logarithm of the value of the TPs contributing to the sequence signal to produce three TP-filters, an exponential ρm-filter, a low pass T1-filter and a high pass T2-filter. Using the univariate model which considers signal changes in only one of ρm, T1, or T2 at a time, the first partial derivative of signal with respect to the natural logarithm of ρm, T1 or T2 is the sequence weighting for each filter (for small changes in each TP). Absolute contrast is then the sequence weighting multiplied by the fractional change in TP for each filter. For large changes in TPs, the same approach is followed, but using the mean slope of the filter as the sequence weighting. These approaches can also be used for fractional contrast. The univariate TP-filter model provides a mathematical framework for converting conventional qualitative univariate weighting as used in everyday clinical practice into quantitative univariate weighting. Using the multivariate model which considers several TP-filters together, the relative contributions of each TP to overall sequence and image weighting are expressed as sequence and imaging weighting ratios respectively. This is not possible with conventional qualitative weighting which is univariate. The same approaches are used for inversion recovery (IR), pulsed gradient SE, spoiled gradient echo (SGE), balanced steady state free precession, ultrashort echo time and other pulse sequences. Other TPs such as susceptibility, chemical shift and flow can be included with phase along the Y axis of the TP-filter. Contrast agent effects are also included. In the text TP-filters are distinguished from k-space filters, signal filters (S-filters) which are used in imaging processing as well as to describe windowing the signal width and level of images, and spatial filters. The TP-filters approach resolves many of the ambiguities and inconsistencies associated with conventional qualitative weighting and provides a variety of new insights into the signal, contrast and weighting of MR images which are not apparent using qualitative weighting. The TP-filter approach relates the preparation component of pulse sequences to voxel signal, and contrast between two voxels. This is complementary to k-space which relates the acquisition component of pulse sequences to the spatial properties of MR images and their global contrast.
Collapse
|
33
|
F. Carvalho WO, Mejía-Salazar JR. Plasmonics for Telecommunications Applications. SENSORS (BASEL, SWITZERLAND) 2020; 20:s20092488. [PMID: 32354016 PMCID: PMC7250033 DOI: 10.3390/s20092488] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 05/08/2023]
Abstract
Plasmonic materials, when properly illuminated with visible or near-infrared wavelengths, exhibit unique and interesting features that can be exploited for tailoring and tuning the light radiation and propagation properties at nanoscale dimensions. A variety of plasmonic heterostructures have been demonstrated for optical-signal filtering, transmission, detection, transportation, and modulation. In this review, state-of-the-art plasmonic structures used for telecommunications applications are summarized. In doing so, we discuss their distinctive roles on multiple approaches including beam steering, guiding, filtering, modulation, switching, and detection, which are all of prime importance for the development of the sixth generation (6G) cellular networks.
Collapse
|
34
|
Gusev PA, Andrews KW, Savarala S, Tey PT, Han F, Oh L, Pehrsson PR, Dwyer JT, Betz JM, Kuszak AJ, Costello R, Saldanha LG. Disintegration and Dissolution Testing of Green Tea Dietary Supplements: Application and Evaluation of United States Pharmacopeial Standards. J Pharm Sci 2020; 109:1933-1942. [PMID: 32081719 DOI: 10.1016/j.xphs.2020.02.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 02/05/2020] [Indexed: 12/23/2022]
Abstract
Approved performance quality tests are lacking in the United States Pharmacopeia (USP) for dietary supplements (DSs) containing green tea extracts. We evaluated the applicability of USP <2040 > general chapter protocols for disintegration and dissolution testing of botanicals to GT DSs. Of 28 single-ingredient GT DSs tested in 2 to 4 lots, 9 (32.1%) always passed the disintegration test, 8 (28.6%) always failed, and 11 (39.3%) showed inconsistent results. Of 34 multi-ingredient DSs tested in 2 lots, 21 (61.8%) passed and 8 (23.5%) failed in both lots, and 5 (14.7%) exhibited inconsistent performance. When stronger destructive forces were applied (disk added), all of the capsules that had failed initially, but not the tablets, passed. In dissolution testing, for the release of epigallocatechin-3-gallate (EGCG), only 6 of 20 single-ingredient DSs passed. Unexpectedly, with the addition of pepsin (prescribed by USP), only one additional DS passed. These results raise concerns that EGCG was not released properly from GT DS dosage forms. However, the general USP protocols may be inadequate for this botanical. More biorelevant destructive forces may be needed to break down capsules and tablets strengthened by the EGCG's interaction with shell material and to overcome the inhibition of digestive enzymes by EGCG.
Collapse
|
35
|
Levoska MA, Griffith JL, Nagai S, Collins K, Lim HW. A multidisciplinary approach utilizing filters for surgical procedures in erythropoietic protoporphyria. J Am Acad Dermatol 2020; 83:e329-e330. [PMID: 32068036 DOI: 10.1016/j.jaad.2020.02.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 02/03/2020] [Indexed: 11/30/2022]
|
36
|
Abstract
Prior to delivery of data, eye tracker software may apply filtering to correct for noise. Although filtering produces much better precision of data, it may add to the time it takes for
the reporting of gaze data to stabilise after a saccade due to
the usage of a sliding window. The effect of various filters and
parameter settings on accuracy, precision and filter related latency is examined. A cost function can be used to obtain the
optimal parameters (filter, length of window, metric and threshold for removal of samples and removal percentage). It was found that for any of the FIR filters, the standard deviation of samples can be used to remove 95% of samples in the window so than an optimum combination of filter related latency and precision can be obtained. It was also confirmed that for unfiltered data, the shape of noise, signified by
RMS/STD, is around
2
as expected for white noise, whereas lower
RMS/STD values were observed for all
filters
Collapse
|
37
|
Ferguson RMW, Garcia‐Alcega S, Coulon F, Dumbrell AJ, Whitby C, Colbeck I. Bioaerosol biomonitoring: Sampling optimization for molecular microbial ecology. Mol Ecol Resour 2019; 19:672-690. [PMID: 30735594 PMCID: PMC6850074 DOI: 10.1111/1755-0998.13002] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Revised: 01/25/2019] [Accepted: 01/29/2019] [Indexed: 12/31/2022]
Abstract
Bioaerosols (or biogenic aerosols) have largely been overlooked by molecular ecologists. However, this is rapidly changing as bioaerosols play key roles in public health, environmental chemistry and the dispersal ecology of microbes. Due to the low environmental concentrations of bioaerosols, collecting sufficient biomass for molecular methods is challenging. Currently, no standardized methods for bioaerosol collection for molecular ecology research exist. Each study requires a process of optimization, which greatly slows the advance of bioaerosol science. Here, we evaluated air filtration and liquid impingement for bioaerosol sampling across a range of environmental conditions. We also investigated the effect of sampling matrices, sample concentration strategies and sampling duration on DNA yield. Air filtration using polycarbonate filters gave the highest recovery, but due to the faster sampling rates possible with impingement, we recommend this method for fine -scale temporal/spatial ecological studies. To prevent bias for the recovery of Gram-positive bacteria, we found that the matrix for impingement should be phosphate-buffered saline. The optimal method for bioaerosol concentration from the liquid matrix was centrifugation. However, we also present a method using syringe filters for rapid in-field recovery of bioaerosols from impingement samples, without compromising microbial diversity for high -throughput sequencing approaches. Finally, we provide a resource that enables molecular ecologists to select the most appropriate sampling strategy for their specific research question.
Collapse
|
38
|
Bonsembiante F, Perazzi A, Deganello A, Gelain ME, Iacopetti I. Impression cytology of the healthy equine ocular surface: Inter-observer agreement, filter preservation over time and comparison with the cytobrush technique. Vet Clin Pathol 2019; 48:61-66. [PMID: 30861155 DOI: 10.1111/vcp.12711] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 07/06/2018] [Accepted: 08/13/2018] [Indexed: 11/30/2022]
Abstract
BACKGROUND The cytobrush technique is commonly used to sample the equine ocular surface. Impression cytology (IC) is an innovative noninvasive method, which allows for the collection of superficial layers of ocular epithelium. OBJECTIVES The aims of this study were to compare the cytobrush and IC techniques on healthy equine ocular surfaces, to assess the agreement between observers with different levels of expertise, and to test the preservability of filters over time. METHODS Twenty-four horses were sampled within 10 minutes of slaughter using IC on the left eye and the cytobrush technique on the right eye. May-Grünwald-Giemsa stained specimens were evaluated by two observers with different levels of expertise. Morphologic features were evaluated using a 4-grade system. The IC samples were re-evaluated after 6 months to examine filter preservation. RESULTS In IC samples, corneal and conjunctival cells were clearly separated. Goblet cells were found in five and 17 filters by observer 1 and 2, respectively. Using the cytobrush technique, corneal and conjunctival cells were present but mixed. Goblet cell cellularity, preservation, and enumeration were higher with the IC technique compared with the cytobrush technique (P = 0.013; P = 0.004; P = 0.031, respectively). The inter-observer agreement for the IC technique was moderate to fair. In 7/24 IC samples re-evaluated after 6 months, cellular morphology was impaired, and the overall score was significantly lower. CONCLUSIONS IC is an innovative noninvasive method, which allows for sample collection with higher cellularity and preservation. Moreover, the identification of goblet cells is easier. For these reasons, IC could be interesting and useful as a complementary diagnostic cytologic method in clinical practice.
Collapse
|
39
|
Güntner AT, Abegg S, Königstein K, Gerber PA, Schmidt-Trucksäss A, Pratsinis SE. Breath Sensors for Health Monitoring. ACS Sens 2019; 4:268-280. [PMID: 30623644 DOI: 10.1021/acssensors.8b00937] [Citation(s) in RCA: 104] [Impact Index Per Article: 20.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Breath sensors can revolutionize medical diagnostics by on-demand detection and monitoring of health parameters in a noninvasive and personalized fashion. Despite extensive research for more than two decades, however, only a few breath sensors have been translated into clinical practice. Actually, most never even left the scientific laboratories. Here, we describe key challenges that currently impede realization of breath sensors and highlight strategies to overcome them. Specifically, we start with breath marker selection (with emphasis on metabolic and inflammatory markers) and breath sampling. Next, the sensitivity, stability, and selectivity requirements for breath sensors are described. Concepts are elaborated to systematically address these requirements by material design (focusing on chemoresistive metal oxides), orthogonal arrays, and filters. Finally, aspects of portable device integration, user communication, and clinical applicability are discussed.
Collapse
|
40
|
Devaraj V, Han J, Kim C, Kang YC, Oh JW. Self-Assembled Nanoporous Biofilms from Functionalized Nanofibrous M13 Bacteriophage. Viruses 2018; 10:v10060322. [PMID: 29895757 PMCID: PMC6024362 DOI: 10.3390/v10060322] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 06/08/2018] [Accepted: 06/12/2018] [Indexed: 12/14/2022] Open
Abstract
Highly periodic and uniform nanostructures, based on a genetically engineered M13 bacteriophage, displayed unique properties at the nanoscale that have the potential for a variety of applications. In this work, we report a multilayer biofilm with self-assembled nanoporous surfaces involving a nanofiber-like genetically engineered 4E-type M13 bacteriophage, which was fabricated using a simple pulling method. The nanoporous surfaces were effectively formed by using the networking-like structural layers of the M13 bacteriophage during self-assembly. Therefore, an external template was not required. The actual M13 bacteriophage-based fabricated multilayered biofilm with porous nanostructures agreed well with experimental and simulation results. Pores formed in the final layer had a diameter of about 150–500 nm and a depth of about 15–30 nm. We outline a filter application for this multilayered biofilm that enables selected ions to be extracted from a sodium chloride solution. Here, we describe a simple, environmentally friendly, and inexpensive fabrication approach with large-scale production potential. The technique and the multi-layered biofilms produced may be applied to sensor, filter, plasmonics, and bio-mimetic fields.
Collapse
|
41
|
Filtration Properties of Auxetics with Rotating Rigid Units. MATERIALS 2018; 11:ma11050725. [PMID: 29751553 PMCID: PMC5978102 DOI: 10.3390/ma11050725] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 04/24/2018] [Accepted: 04/25/2018] [Indexed: 02/06/2023]
Abstract
Auxetic structures and materials expand laterally when stretched. It has been argued that this property could be applied in the design of smart filters with tunable sieving properties. This work analyses the filtration properties of a class of auxetic structures which achieve their auxeticity through a rotating rigid unit mechanism, an archetypal mechanism known to be responsible for this behavior in a number of crystalline materials. In particular, mathematical expressions are derived for the space coverage of networks constructed from a variety of quadrilaterals, as well as the pore radius. The latter is indicative of the particle size that can pass through when the particle dimension is comparable to the pore size, whereas the space coverage is indicative of the rate of flow when the particles are of a much smaller dimension than the pore size. The expressions suggest that these systems offer a wide range of pore sizes and space coverages, both of which can be controlled through the way that the units are connected to each other, their shape and the angle between them.
Collapse
|
42
|
Filter-Based Phase Shifts Distort Neuronal Timing Information. eNeuro 2018; 5:eN-MNT-0261-17. [PMID: 29766044 PMCID: PMC5952323 DOI: 10.1523/eneuro.0261-17.2018] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 04/03/2018] [Accepted: 04/06/2018] [Indexed: 11/21/2022] Open
Abstract
Filters are widely used for the modulation, typically attenuation, of amplitudes of different frequencies within neurophysiological signals. Filters, however, also induce changes in the phases of different frequencies whose amplitude is unmodulated. These phase shifts cause time lags in the filtered signals, leading to a disruption of the timing information between different frequencies within the same signal and between different signals. The emerging time lags can be either constant in the case of linear phase (LP) filters or vary as a function of the frequency in the more common case of non-LP (NLP) filters. Since filters are used ubiquitously online in the early stages of data acquisition, the vast majority of neurophysiological signals thus suffer from distortion of the timing information even prior to their sampling. This distortion is often exacerbated by further multiple offline filtering stages of the sampled signal. The distortion of timing information may cause misinterpretation of the results and lead to erroneous conclusions. Here we present a variety of typical examples of filter-induced phase distortions and discuss the evaluation and restoration of the timing information underlying the original signal.
Collapse
|
43
|
Chubaka CE, Whiley H, Edwards JW, Ross KE. Microbiological Values of Rainwater Harvested in Adelaide. Pathogens 2018; 7:E21. [PMID: 29419793 PMCID: PMC5874747 DOI: 10.3390/pathogens7010021] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 01/23/2018] [Accepted: 02/04/2018] [Indexed: 11/22/2022] Open
Abstract
In Australia, rainwater is an important source of water for many households. Unlike municipal water, rainwater is often consumed untreated. This study investigated the potential contamination of rainwater by microorganisms. Samples from 53 rainwater tanks across the Adelaide region were collected and tested using Colilert™ IDEXX Quanti-Tray*/2000. Twenty-eight out of the 53 tanks (53%) contained Escherichia coli. Samples collected from ten tanks contained E. coli at concentrations exceeding the limit of 150 MPN/100 mL for recreational water quality. A decline in E. coli was observed in samples collected after prolonged dry periods. Rainwater microbiological values depended on the harvesting environment conditions. A relationship was found between mounted TV antenna on rooftops and hanging canopies; and E. coli abundance. Conversely, there was no relationship between seasonality and E. coli or roof and tank structure materials and E. coli. In several tanks used for drinking water, samples collected prior to and after filtration showed that the filtration systems were not always successful at completely removing E. coli. These results differed from a study undertaken in the laboratory that found that a commercially available in-bench 0.45 µm filter cartridge successfully reduced E. coli in rainwater to 0 MPN/100 mL. After running a total of 265 L of rainwater which contained high levels of E. coli through the filter (half of the advertised filter lifespan), the filter cartridge became blocked, although E. coli remained undetected in filtered water. The difference between the laboratory study and field samples could be due to improper maintenance or installation of filters or recontamination of the faucet after filtration. The presence of E. coli in water that is currently used for drinking poses a potential health concern and indicates the potential for contamination with other waterborne pathogens.
Collapse
|
44
|
Uhrbrand K, Koponen IK, Schultz AC, Madsen AM. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus. J Appl Microbiol 2017; 124:990-1000. [PMID: 28921812 DOI: 10.1111/jam.13588] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 09/14/2017] [Accepted: 09/14/2017] [Indexed: 11/27/2022]
Abstract
AIMS The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). METHODS AND RESULTS A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P < 0·05) higher recovery of aerosolized MNV than 3P and NIO. A higher recovery was also found for GSP compared with TC, albeit not significantly. Finally, recovery of aerosolized MNV was significantly (P < 0·05) higher using NY than PC, PTFE and GEL filters. CONCLUSIONS The GSP sampler combined with a nylon filter was found to be the best method for personal filter-based sampling of airborne NoV. SIGNIFICANCE AND IMPACT OF THE STUDY The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection.
Collapse
|
45
|
Stevenson AW, Di Lillo F. Estimating the absolute flux distribution for a synchrotron X-ray beam using ionization-chamber measurements with various filters. JOURNAL OF SYNCHROTRON RADIATION 2017; 24:939-953. [PMID: 28862616 DOI: 10.1107/s1600577517009274] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2017] [Accepted: 06/20/2017] [Indexed: 06/07/2023]
Abstract
It is shown that an extensive set of accurate ionization-chamber measurements with a primary polychromatic synchrotron X-ray beam transmitted through various filter combinations/thicknesses can be used to quite effectively estimate the absolute flux distribution. The basic technique is simple but the `inversion' of the raw data to extract the flux distribution is a fundamentally ill-posed problem. It is demonstrated, using data collected at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron, that the absolute flux can be quickly and reliably estimated if a suitable choice of filters is made. Results are presented as a function of the magnetic field (from 1.40 to 4.00 T) of the superconducting multi-pole wiggler insertion device installed at IMBL. A non-linear least-squares refinement of the data is used to estimate the incident flux distribution and then comparison is made with calculations from the programs SPECTRA, XOP and spec.exe. The technique described is important not only in estimating flux itself but also for a variety of other, derived, X-ray properties such as beam quality, power density and absorbed-dose rate. The applicability of the technique with a monochromatic X-ray beam for which there is significant harmonic contamination is also demonstrated. Whilst absolute results can also be derived in this monochromatic beam case, relative (integrated) flux values are sufficient for our primary aim of establishing reliable determinations of the percentages of the various harmonic components.
Collapse
|
46
|
Aronson MFJ, Nilon CH, Lepczyk CA, Parker TS, Warren PS, Cilliers SS, Goddard MA, Hahs AK, Herzog C, Katti M, La Sorte FA, Williams NSG, Zipperer W. Hierarchical filters determine community assembly of urban species pools. Ecology 2017; 97:2952-2963. [PMID: 27870023 DOI: 10.1002/ecy.1535] [Citation(s) in RCA: 188] [Impact Index Per Article: 26.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Revised: 05/30/2016] [Accepted: 07/05/2016] [Indexed: 12/15/2022]
Abstract
The majority of humanity now lives in cities or towns, with this proportion expected to continue increasing for the foreseeable future. As novel ecosystems, urban areas offer an ideal opportunity to examine multi-scalar processes involved in community assembly as well as the role of human activities in modulating environmental drivers of biodiversity. Although ecologists have made great strides in recent decades at documenting ecological relationships in urban areas, much remains unknown, and we still need to identify the major ecological factors, aside from habitat loss, behind the persistence or extinction of species and guilds of species in cities. Given this paucity of knowledge, there is an immediate need to facilitate collaborative, interdisciplinary research on the patterns and drivers of biodiversity in cities at multiple spatial scales. In this review, we introduce a new conceptual framework for understanding the filtering processes that mold diversity of urban floras and faunas. We hypothesize that the following hierarchical series of filters influence species distributions in cities: (1) regional climatic and biogeographical factors; (2) human facilitation; (3) urban form and development history; (4) socioeconomic and cultural factors; and (5) species interactions. In addition to these filters, life history and functional traits of species are important in determining community assembly and act at multiple spatial scales. Using these filters as a conceptual framework can help frame future research needed to elucidate processes of community assembly in urban areas. Understanding how humans influence community structure and processes will aid in the management, design, and planning of our cities to best support biodiversity.
Collapse
|
47
|
Decelis S, Sardella D, Triganza T, Brincat JP, Gatt R, Valdramidis VP. Assessing the anti-fungal efficiency of filters coated with zinc oxide nanoparticles. ROYAL SOCIETY OPEN SCIENCE 2017; 4:161032. [PMID: 28572995 PMCID: PMC5451796 DOI: 10.1098/rsos.161032] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 04/06/2017] [Indexed: 06/07/2023]
Abstract
Air filters support fungal growth, leading to generation of conidia and volatile organic compounds, causing allergies, infections and food spoilage. Filters that inhibit fungi are therefore necessary. Zinc oxide (ZnO) nanoparticles have anti-fungal properties and therefore are good candidates for inhibiting growth. Two concentrations (0.012 M and 0.12 M) were used to coat two types of filters (melt-blown and needle-punched) for three different periods (0.5, 5 and 50 min). Rhizopus stolonifer and Penicillium expansum isolated from spoiled pears were used as test organisms. Conidial suspensions of 105 to 103 spores ml-1 were prepared in Sabouraud dextrose agar at 50°C, and a modified slide-culture technique was used to test the anti-fungal properties of the filters. Penicillium expansum was the more sensitive organism, with inhibition at 0.012 M at only 0.5 min coating time on the needle-punched filter. The longer the coating time, the more effective inhibition was for both organisms. Furthermore, it was also determined that the coating process had only a slight effect on the Young's Moduli of the needle-punched filters, while the Young's Moduli of the melt-blown filters is more susceptible to the coating method. This work contributes to the assessment of the efficacy of filter coating with ZnO nanopaticles aimed at inhibiting fungal growth.
Collapse
|
48
|
Vaughan N, Rajan-Sithamparanadarajah B, Atkinson R. Evaluation of RPE-Select: A Web-Based Respiratory Protective Equipment Selector Tool. ANNALS OF OCCUPATIONAL HYGIENE 2016; 60:900-12. [PMID: 27286763 DOI: 10.1093/annhyg/mew035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 04/29/2016] [Indexed: 12/30/2022]
Abstract
This article describes the evaluation of an open-access web-based respiratory protective equipment selector tool (RPE-Select, accessible at http://www.healthyworkinglives.com/rpe-selector). This tool is based on the principles of the COSHH-Essentials (C-E) control banding (CB) tool, which was developed for the exposure risk management of hazardous chemicals in the workplace by small and medium sized enterprises (SMEs) and general practice H&S professionals. RPE-Select can be used for identifying adequate and suitable RPE for dusts, fibres, mist (solvent, water, and oil based), sprays, volatile solids, fumes, gases, vapours, and actual or potential oxygen deficiency. It can be applied for substances and products with safety data sheets as well as for a large number of commonly encountered process-generated substances (PGS), such as poultry house dusts or welding fume. Potential international usability has been built-in by using the Hazard Statements developed for the Globally Harmonised System (GHS) and providing recommended RPE in picture form as well as with a written specification. Illustration helps to compensate for the variabilities in assigned protection factors across the world. RPE-Select uses easily understandable descriptions/explanations and an interactive stepwise flow for providing input/answers at each step. The output of the selection process is a report summarising the user input data and a selection of RPE, including types of filters where applicable, from which the user can select the appropriate one for each wearer. In addition, each report includes 'Dos' and 'Don'ts' for the recommended RPE. RPE-Select outcomes, based on up to 20 hypothetical use scenarios, were evaluated in comparison with other available RPE selection processes and tools, and by 32 independent users with a broad range of familiarities with industrial use scenarios in general and respiratory protection in particular. For scenarios involving substances having safety data sheets, 87% of RPE-Select outcomes resulted in a 'safe' RPE selection, while 98% 'safe' outcomes were achieved for scenarios involving process-generated substances. Reasons for the outliers were examined. User comments and opinions on the mechanics and usability of RPE-Select are also presented.
Collapse
|
49
|
Rana N, Rawat D, Parmar M, Dhawan DK, Bhati AK, Mittal BR. Evaluation of external beam hardening filters on image quality of computed tomography and single photon emission computed tomography/computed tomography. J Med Phys 2016; 40:198-206. [PMID: 26865755 PMCID: PMC4728890 DOI: 10.4103/0971-6203.170790] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
This study was undertaken to evaluate the effect of external metal filters on the image quality of computed tomography (CT) and single photon emission computed tomography (SPECT)/CT images. Images of Jaszack phantom filled with water and containing iodine contrast filled syringes were acquired using CT (120 kV, 2.5 mA) component of SPECT/CT system, ensuring fixation of filter on X-ray collimator. Different thickness of filters of Al and Cu (1 mm, 2 mm, 3 mm, and 4 mm) and filter combinations Cu 1 mm, Cu 2 mm, Cu 3 mm each in combination with Al (1 mm, 2 mm, 3 mm, and 4 mm), respectively, were used. All image sets were visually analyzed for streak artifacts and contrast to noise ratio (CNR) was derived. Similar acquisition was done using Philips CT quality control (QC) phantom and CNR were calculated for its lexan, perspex, and teflon inserts. Attenuation corrected SPECT/CT images of Jaszack phantom filled with 444-555 MBq (12-15 mCi) of (99m)Tc were obtained by applying attenuation correction map generated by hardened X-ray beam for different filter combination, on SPECT data. Uniformity, root mean square (rms) and contrast were calculated in all image sets. Less streak artifacts at iodine water interface were observed in images acquired using external filters as compared to those without a filter. CNR for syringes, spheres, and inserts of Philips CT QC phantom was almost similar to Al 2 mm, Al 3 mm, and without the use of filters. CNR decreased with increasing copper thickness and other filter combinations. Uniformity and rms were lower, and value of contrast was higher for SPECT/CT images when CT was acquired with Al 2 mm and 3 mm filter than for images acquired without a filter. The study suggests that for Infinia Hawkeye 4, SPECT/CT system, Al 2 mm, and 3 mm are the optimum filters for improving image quality of SPECT/CT images of Jaszack or Philips CT QC phantom keeping other parameters of CT constant.
Collapse
|
50
|
Li H, Zhang A, Hu S. A Multispectral Image Creating Method for a New Airborne Four-Camera System with Different Bandpass Filters. SENSORS 2015. [PMID: 26205264 PMCID: PMC4541943 DOI: 10.3390/s150717453] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This paper describes an airborne high resolution four-camera multispectral system which mainly consists of four identical monochrome cameras equipped with four interchangeable bandpass filters. For this multispectral system, an automatic multispectral data composing method was proposed. The homography registration model was chosen, and the scale-invariant feature transform (SIFT) and random sample consensus (RANSAC) were used to generate matching points. For the difficult registration problem between visible band images and near-infrared band images in cases lacking manmade objects, we presented an effective method based on the structural characteristics of the system. Experiments show that our method can acquire high quality multispectral images and the band-to-band alignment error of the composed multiple spectral images is less than 2.5 pixels.
Collapse
|