101
|
Kertesz V, Van Berkel GJ. Improved imaging resolution in desorption electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:2639-44. [PMID: 18666197 DOI: 10.1002/rcm.3662] [Citation(s) in RCA: 88] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The imaging resolution of desorption electrospray ionization mass spectrometry (DESI-MS) was investigated using printed patterns on paper and thin-layer chromatography (TLC) plate surfaces. Resolution approaching 40 microm was achieved with a typical DESI-MS setup, which is approximately 5 times better than the best resolution reported previously. This improvement was accomplished with careful control of operational parameters (particularly spray tip-to-surface distance, solvent flow rate, and spacing of lane scans). In addition, an appropriately strong analyte/surface interaction and uniform surface texture on the size scale no larger than the desired imaging resolution were required to achieve this resolution. Overall, conditions providing the smallest possible effective desorption/ionization area in the DESI impact plume region and minimizing the analyte redistribution on the surface during analysis led to improved DESI-MS imaging resolution.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6131, USA.
| | | |
Collapse
|
102
|
Fournier I, Wisztorski M, Salzet M. Tissue imaging using MALDI-MS: a new frontier of histopathology proteomics. Expert Rev Proteomics 2008; 5:413-24. [PMID: 18532909 DOI: 10.1586/14789450.5.3.413] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Modern pathology is an amalgam of many disciplines, such as microbiology, biochemistry and immunology, which historically have been intermingled with the practice of clinical medicine. For centuries, the pre-eminent pathological tool, at least in the context of patients, was a post-mortem examination. With the advent of optical microscopes, morphology became a predominant means of developing tissue classification. A further paradigm shift occurred in the attempt to understand the nature and origin of disease; the recognition that, ultimately, it is the derangement in the structure and function of genes and proteins that causes human disease. More recent progress in pathology has led to the use of genomics and molecular technologies, including DNA sequencing, microarray analysis, PCR, in situ hybridization and proteomics. Today, the newest frontier appears to be histopathology proteomics, which adds the mass spectrometer to the arsenal of tools for the direct analysis of tissue biopsies and molecular diagnosis. Typically called MALDI imaging, this technique takes mass spectral snapshots of intact tissue slices, revealing how proteins and peptides are spatially distributed within a given sample. In this review, MALDI imaging technology is presented as well as applications of such technology in cancer or neurodegenerative diseases.
Collapse
Affiliation(s)
- Isabelle Fournier
- Laboratoire de Neurobiologie des Annélides, FRE CNRS 2933, MALDI Imaging Team, University of Lille 1, F-59655 Villeneuve d'Ascq Cedex, France.
| | | | | |
Collapse
|
103
|
Talaty N, Mulligan CC, Justes DR, Jackson AU, Noll RJ, Cooks RG. Fabric analysis by ambient mass spectrometry for explosives and drugs. Analyst 2008; 133:1532-40. [PMID: 18936830 DOI: 10.1039/b807934j] [Citation(s) in RCA: 91] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Desorption electrospray ionization (DESI) is applied to the rapid, in-situ, direct qualitative and quantitative analysis of mixtures of explosives and drugs from a variety of fabrics, including cotton, silk, denim, polyester, rayon, spandex, leather and their blends. The compounds analyzed were explosives: trinitrohexahydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN) and the drugs of abuse: heroin, cocaine, and methamphetamine. Limits of detection are in the picogram range. DESI analyses were performed without sample preparation and carried out in the presence of common interfering chemical matrices, such as insect repellant, urine, and topical lotions. Spatial and depth profiling was investigated to examine the depth of penetration and lateral resolution. DESI was also used to examine cotton transfer swabs used for travel security sample collection in the screening process. High throughput quantitative analysis of fabric surfaces for targeted analytes is also reported.
Collapse
Affiliation(s)
- Nari Talaty
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | | | | | | | | |
Collapse
|
104
|
Lin Z, Zhang S, Zhao M, Yang C, Chen D, Zhang X. Rapid screening of clenbuterol in urine samples by desorption electrospray ionization tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:1882-8. [PMID: 18470868 DOI: 10.1002/rcm.3565] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Rapid screening of clenbuterol in urine was performed by combining desorption electrospray ionization (DESI) and tandem mass spectrometry (MS/MS). Optimization experiments were carried out including the selection of substrates, spray solutions, nebulizing gas pressures, high-voltage power supplies and flow rates of spray solution. The limit of detection (LOD), defined as the lowest quantity that can be detected, was 5.0 pg for the pure compound. Using DESI coupled with solid-phase extraction (SPE), the linear response range was from 10 to 400 ng/mL (R(2) = 0.993) and the concentration LOD for urine sample was 2.0 ng/mL. The analysis for one spiked urine sample was achieved within 4 min. In addition to the fast analysis speed, MS/MS provided structural information for the confirmation of clenbuterol. Urine samples from different people were investigated and the recoveries were within 100 +/- 20%. The developed method can potentially be used for screening of clenbuterol in doping control.
Collapse
Affiliation(s)
- Ziqing Lin
- Department of Chemistry, Tsinghua University, 100084 Beijing, People's Republic of China
| | | | | | | | | | | |
Collapse
|
105
|
Arráez-Román D, Zurek G, Bäßmann C, Segura-Carretero A, Fernández-Gutiérrez A. Characterization ofAtropa belladonna L. compounds by capillary electrophoresis-electrospray ionization-time of flight-mass spectrometry and capillary electrophoresis-electrospray ionization-ion trap-mass spectrometry. Electrophoresis 2008; 29:2112-6. [DOI: 10.1002/elps.200700468] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
106
|
Kauppila TJ, Arvola V, Haapala M, Pól J, Aalberg L, Saarela V, Franssila S, Kotiaho T, Kostiainen R. Direct analysis of illicit drugs by desorption atmospheric pressure photoionization. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:979-85. [PMID: 18320545 DOI: 10.1002/rcm.3461] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The feasibility of desorption atmospheric pressure photoionization (DAPPI) in the direct analysis of illicit drugs was demonstrated by the analysis of confiscated drug samples of various forms such as tablets, blotter paper, and plant resin and bloom. 3,4-Methylenedioxymethamphetamine (MDMA), amphetamine, phenazepam, and buprenorphine were detected from the analyzed tablets, lysergic acid diethylamide (LSD) and bromobenzodifuranylisopropylamine (bromo-Dragonfly, ABDF) from blotter paper, and Delta(9)-tetrahydrocannabinol (THC) and cannabinol from Cannabis Sativa bloom and resin. The amphetamines, phenazepam and ABDF showed protonated molecules independent of the solvent used, whereas buprenorphine, LSD and the cannabinoids showed molecular ions with toluene and protonated molecules with acetone as the solvent.
Collapse
Affiliation(s)
- Tiina J Kauppila
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, P.O. Box 56, FI-00014 University of Helsinki, Finland.
| | | | | | | | | | | | | | | | | |
Collapse
|
107
|
Andrade FJ, Shelley JT, Wetzel WC, Webb MR, Gamez G, Ray SJ, Hieftje GM. Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds. Anal Chem 2008; 80:2654-63. [PMID: 18345694 DOI: 10.1021/ac800210s] [Citation(s) in RCA: 166] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The flowing afterglow-atmospheric pressure glow discharge (APGD) ionization source described in part 1 of this study (in this issue) is applied to the direct analysis of condensed-phase samples. When either liquids or solids are exposed to the ionizing beam of the APGD, strong signals for the molecular ions of substances present on their surfaces can be detected without compromising the integrity of the solid sample structure or sample substrate. As was observed for gas-phase compounds in part 1 of this study, both polar and nonpolar substances can be ionized and detected by mass spectrometry. The parent molecular ion (or its protonated counterpart) is usually the main spectral feature, with little or no fragmentation in evidence. Preliminary quantitative results show that this approach offers very good sensitivity (detection limits in the picogram regime are reported for several test compounds in part 1 of this study) and linear response to the analyte concentration. Examples of the application of this strategy to the analysis of real-world samples, such as the direct analysis of pharmaceutical compounds or foods is provided. The ability of this source to perform spatially resolved analysis is also demonstrated. Preliminary studies of the mechanisms of the reactions involved are described.
Collapse
Affiliation(s)
- Francisco J Andrade
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, USA
| | | | | | | | | | | | | |
Collapse
|
108
|
|
109
|
Takats Z, Kobliha V, Sevcik K, Novak P, Kruppa G, Lemr K, Havlicek V. Characterization of DESI-FTICR mass spectrometry - from ECD to accurate mass tissue analysis. JOURNAL OF MASS SPECTROMETRY : JMS 2008; 43:196-203. [PMID: 17918779 DOI: 10.1002/jms.1285] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Implementation of desorption electrospray ionization (DESI) technique on a 9.4 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer is described. Desorption electrospray technique is capable of the direct investigation of natural samples without any need for sample preparation or chromatographic separation. Since the DESI mass spectra of natural samples are very complex owing to the lack of preseparation or cleanup, the ideal mass spectrometric analyzer for these applications is a high-resolution instrument such as FTICR mass spectrometer. DESI was implemented by constructing an electronically controlled source framework comprising six linear moving stages and one rotating stage. A three-dimensional linear stage was used to accommodate samples, while another 3D linear stage equipped with rotating stage was used as a spray mount. A modified electrosonic sprayer was used as a primary electrospray device. DESI-FTICR setup was characterized with regard to geometrical, electrical and flow conditions using deposited peptide samples in range of 1-100 pmol gross deposited amount on glass and polymer surfaces. Optimized conditions enabled the routine acquisition of DESI-MS spectra on the instrument at 130 000 resolution in the broadband mode and with comparable sensitivity to data reported in the literature. Since the main significance of DESI-FTICR MS is the combination of intact tissue analysis, the capabilities of the technique were demonstrated by analyzing murine liver samples. Presence of lysophospholipids in the liver tissue was tentatively associated with the lipid metabolism taking place in liver. DESI-FTICR is also a promising technique in the field of peptide analysis due to capability of top-down sequencing using electron capture dissociation. As a proof-of-principle experiment, a small synthetic polypeptide containing 36 amino acids was ionized using DESI and was sequenced in the FTICR by means of ECD (electron capture dissociation) fragmentation. Spectra gave almost full sequence information in agreement with the known amino acid sequence of the species.
Collapse
Affiliation(s)
- Zoltan Takats
- Semmelweis University, VIII. Ulloi ut 26, 1085 Budapest, Hungary
| | | | | | | | | | | | | |
Collapse
|
110
|
Sen AK, Nayak R, Darabi J, Knapp DR. Use of nanoporous alumina surface for desorption electrospray ionization mass spectrometry in proteomic analysis. Biomed Microdevices 2008; 10:531-8. [DOI: 10.1007/s10544-007-9162-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
111
|
Kertesz V, Van Berkel GJ. Scanning and surface alignment considerations in chemical imaging with desorption electrospray mass spectrometry. Anal Chem 2008; 80:1027-32. [PMID: 18193892 DOI: 10.1021/ac701947d] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The effects of surface scanning mode (raster vs unidirectional scanning) and the constancy of spray tip-to-surface and atmospheric sampling interface capillary-to-surface distances on chemical image quality using desorption electrospray ionization mass spectrometry were investigated. Unidirectional scanning was found to provide a spatially and a quantitatively more precise chemical image of the surface as compared to raster scanning. Maintaining constant spray tip-to-surface and atmospheric sampling interface capillary-to-surface distances during an imaging experiment was found to also be critical. An automation process was implemented using a custom image analysis software (HandsFree Surface Analysis) to keep these distances constant during the surface sampling experiment. Improved chemical image quality afforded through this software control was illustrated by imaging printed objects on normal copy paper.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6131, USA.
| | | |
Collapse
|
112
|
Pól J, Novák P, Volný M, Kruppa GH, Kostiainen R, Lemr K, Havlícek V. Application of silicon nanowires and indium tin oxide surfaces in desorption electrospray ionization. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2008; 14:391-399. [PMID: 19136727 DOI: 10.1255/ejms.961] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Two nanostructured surfaces are introduced as advantageous substrates for desorption electrospray ionization mass spectrometry (DESI-MS). Nano-assisted laser desorption/ionization (NALDI) plates coated with silicon nanowires (SiNWs) and indium tin oxide (ITO) layers on glass are both conductive non-polar surfaces that were originally designed as superior substrates for matrix-free laser desorption/ionization. In this study, NALDI/SiNWs and ITO were tested as potentially useful DESI substrates for selected model analytes (cyclosporine, beauverolide, surfactin and nystatin). Both nanostructured surfaces produced more intense and longer-lasting signals than other tested surfaces (polytetrafluoroethylene, glass, polymethylmethacrylate and chromatography paper).
Collapse
Affiliation(s)
- Jaroslav Pól
- Laboratory of Molecular Structure Characterization, Institute of Microbiology, Academy of Sciences of the Czech Republic.
| | | | | | | | | | | | | |
Collapse
|
113
|
Chapter 1 Challenges in Chemical Food Contaminants and Residue Analysis. FOOD CONTAMINANTS AND RESIDUE ANALYSIS 2008. [DOI: 10.1016/s0166-526x(08)00001-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
114
|
ERRA-BALSELLS R, NONAMI H. UV-MALDI-TOF MS Analysis of Carbohydrates. Reviewing Comparative Studies Performed Using nor-Harmane and Classical UV-MALDI Matrices. ACTA ACUST UNITED AC 2008. [DOI: 10.2525/ecb.46.65] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
115
|
Chen H, Liang H, Ding J, Lai J, Huan Y, Qiao X. Rapid differentiation of tea products by surface desorption atmospheric pressure chemical ionization mass spectrometry. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2007; 55:10093-10100. [PMID: 18020412 DOI: 10.1021/jf0720234] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Protonated water molecules generated by an ambient corona discharge were directed to impact tea leaves for desorption/ionization at atmospheric pressure. Thus, a novel method based on surface desorption chemical ionization mass spectrometry (DAPCI-MS) has been developed for rapid analysis of tea products without any sample pretreatment. Under the optimized experimental conditions, DAPCI MS spectra of various tea samples are recorded rapidly, and the resulting mass spectra are chemical fingerprints that characterize the tea samples. On the basis of the mass spectral fingerprints, 40 tea samples including green tea, oolong tea, and jasmine tea were successfully differentiated by principal component analysis (PCA) of the mass spectral raw data. The PCA results were also validated with cluster analysis and supervised PCA analysis. The alteration of signal intensity caused by rough surfaces of tea leaves did not cause failure in the separation of the tea products. The experimental findings show that DAPCI-MS creates ions of both volatile and nonvolatile compounds in tea products at atmospheric pressure, providing a practical and convenient tool for high-throughput differentiation of tea products.
Collapse
Affiliation(s)
- Huanwen Chen
- Applied Chemistry Department, East China Institute of Technology, Fuzhou, China.
| | | | | | | | | | | |
Collapse
|
116
|
Jackson AU, Talaty N, Cooks RG, Van Berkel GJ. Salt tolerance of desorption electrospray ionization (DESI). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2007; 18:2218-2225. [PMID: 17977744 DOI: 10.1016/j.jasms.2007.09.018] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2007] [Revised: 09/18/2007] [Accepted: 09/20/2007] [Indexed: 05/25/2023]
Abstract
The salt tolerance of desorption electrospray ionization (DESI) was systematically investigated by examining three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl (1:1) from different surfaces. At physiological salt concentrations, the individual drugs in each mixture were observed in each experiment. Even at salt concentrations significantly above physiological levels, particular surfaces were effective in providing spectra that allowed the ready identification of the compounds of interest in low nanogram amounts. Salt adducts, which are observed even in the absence of added salt, could be eliminated by adding 0.1% 7 M ammonium acetate to the standard methanol:water (1:1) spray solvent. Comparison of the salt tolerance of DESI with that of electrospray ionization (ESI) demonstrated better signal/noise characteristics for DESI. The already high salt tolerance of DESI can be optimized further by appropriate choices of surface and spray solution.
Collapse
Affiliation(s)
- Ayanna U Jackson
- Department of Chemistry, Purdue University and Bindley Bioscience Center, Discovery Park at Purdue University, West Lafayette, Indiana 47907, USA
| | | | | | | |
Collapse
|
117
|
Huang G, Chen H, Zhang X, Cooks RG, Ouyang Z. Rapid screening of anabolic steroids in urine by reactive desorption electrospray ionization. Anal Chem 2007; 79:8327-32. [PMID: 17918908 DOI: 10.1021/ac0711079] [Citation(s) in RCA: 176] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Fast screening for anabolic steroids in whole urine is achieved by combining reactive desorption electrospray ionization (reactive DESI) and tandem mass spectrometry. Spray solutions containing hydroxylamine allow heterogeneous reactions of hydroxylamine with the carbonyl group of the steroids during the ionization process. Seven steroids, including a glycosteroid, were examined. The ion/molecule reaction adduct and the oxime formed via its dehydration were observed using reactive DESI; the protonated and sodiated forms of the ionized steroid were also observed both in reactive DESI and in DESI performed without the added hydroxylamine reagent. Paper, glass, and polytetrafluoroethylene were tested as sample substrates, but the glycosteroid was ionized intact without hydrolysis only from polytetrafluoroethylene. Limits of detection for the pure compounds were less than 1 ng, dynamic ranges were typically 2 orders of magnitude, and analysis times were just a few seconds. Concentration levels of ketosteroids in raw urine relevant to screening for sports doping (approximately 20 ng/mL) can be reached using a simple solid-phase microextraction (SPME) preconcentration step. Reactive DESI provided significant improvements in ionization efficiency of these steroids in raw undiluted urine as compared to conventional DESI; suppression effects due to the sample matrix were minimal and the urine matrix had no deleterious effect on steroid detection limits. Tandem mass spectrometry provided confirmation of analyte identification in this rapid screening process.
Collapse
Affiliation(s)
- Guangming Huang
- Department of Chemistry, Tsinghua University, Beijing 100084, China
| | | | | | | | | |
Collapse
|
118
|
Keil A, Talaty N, Janfelt C, Noll RJ, Gao L, Ouyang Z, Cooks RG. Ambient mass spectrometry with a handheld mass spectrometer at high pressure. Anal Chem 2007; 79:7734-9. [PMID: 17867653 DOI: 10.1021/ac071114x] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The first coupling of atmospheric pressure ionization methods, electrospray ionization (ESI) and desorption electrospray ionization (DESI), to a miniature hand-held mass spectrometer is reported. The instrument employs a rectilinear ion trap (RIT) mass analyzer and is battery-operated, hand-portable, and rugged (total system: 10 kg, 0.014 m(3), 75 W power consumption). The mass spectrometer was fitted with an atmospheric inlet, consisting of a 10 cm x 127 microm inner diameter stainless steel capillary tube which was used to introduce gas into the vacuum chamber at 13 mL/min. The operating pressure was 15 mTorr. Ions, generated by the atmospheric pressure ion source, were directed by the inlet along the axis of the ion trap, entering through an aperture in the dc-biased end plate, which was also operated as an ion gate. ESI and DESI sources were used to generate ions; ESI-MS analysis of an aqueous mixture of drugs yielded detection limits in the low parts-per-billion range. Signal response was linear over more than 3 orders of magnitude. Tandem mass spectrometry experiments were used to identify components of this mixture. ESI was also applied to the analysis of peptides and in this case multiply charged species were observed for compounds of molecular weight up to 1200 Da. Cocaine samples deposited or already present on different surfaces, including currency, were rapidly analyzed in situ by DESI. A geometry-independent version of the DESI ion source was also coupled to the miniature mass spectrometer. These results demonstrate that atmospheric pressure ionization can be implemented on simple portable mass spectrometry systems.
Collapse
Affiliation(s)
- Adam Keil
- Chemistry Department, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907, USA
| | | | | | | | | | | | | |
Collapse
|
119
|
Haapala M, Pól J, Saarela V, Arvola V, Kotiaho T, Ketola RA, Franssila S, Kauppila TJ, Kostiainen R. Desorption Atmospheric Pressure Photoionization. Anal Chem 2007; 79:7867-72. [PMID: 17803282 DOI: 10.1021/ac071152g] [Citation(s) in RCA: 202] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
An ambient ionization technique for mass spectrometry, desorption atmospheric pressure photoionization (DAPPI), is presented, and its application to the rapid analysis of compounds of various polarities on surfaces is demonstrated. The DAPPI technique relies on a heated nebulizer microchip delivering a heated jet of vaporized solvent, e.g., toluene, and a photoionization lamp emitting 10-eV photons. The solvent jet is directed toward sample spots on a surface, causing the desorption of analytes from the surface. The photons emitted by the lamp ionize the analytes, which are then directed into the mass spectrometer. The limits of detection obtained with DAPPI were in the range of 56-670 fmol. Also, the direct analysis of pharmaceuticals from a tablet surface was successfully demonstrated. A comparison of the performance of DAPPI with that of the popular desorption electrospray ionization method was done with four standard compounds. DAPPI was shown to be equally or more sensitive especially in the case of less polar analytes.
Collapse
Affiliation(s)
- Markus Haapala
- Division of Pharmaceutical Chemistry, Faculty of Pharmacy, P.O. Box 56, FI-00014 University of Helsinki, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
120
|
Meetani MA, Shin YS, Zhang S, Mayer R, Basile F. Desorption electrospray ionization mass spectrometry of intact bacteria. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:1186-93. [PMID: 17628040 DOI: 10.1002/jms.1250] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate seven bacteria species on the basis of their measured DESI-mass spectral profile. Both gram-positive and gram-negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordetella bronchiseptica, Bacillus thuringiensis, Bacillus subtilis and Salmonella typhimurium. Distinct DESI-mass spectra, in the mass range of 50-500 u, were obtained from whole bacteria in either positive or negative ion modes in less than 2 mins analysis time. Positive ion DESI-mass spectral fingerprints were compared using principal components analysis (PCA) to investigate reproducibility for the intraday and the day-to-day measurements and the method selectivity to differentiate the bacteria studied. Detailed study of variances in the assay revealed that a large contribution to the DESI-mass spectral fingerprint variation was the growth media preparation procedure. Specifically, experiments conducted with the growth media prepared using the same batch yielded highly reproducible DESI-mass spectra, both in intraday and in day-to-day analyses (i.e. one batch of growth media used over a 3-day period versus a new batch every day over the same 3-day period). Conclusions are drawn from our findings in terms of strategies for rapid biodetection with DESI-MS.
Collapse
Affiliation(s)
- Mohammed A Meetani
- Department of Chemistry, Faculty of Science, United Arab Emirates University, Al Ain, United Arab Emirates
| | | | | | | | | |
Collapse
|
121
|
Chen H, Wortmann A, Zenobi R. Neutral desorption sampling coupled to extractive electrospray ionization mass spectrometry for rapid differentiation of biosamples by metabolomic fingerprinting. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:1123-35. [PMID: 17721903 DOI: 10.1002/jms.1282] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
It is of increasing interest and practical importance to develop convenient methods based on mass spectrometry for high-throughput analyses of biological samples. This is usually difficult because of the complex matrix and ion suppression effects. Generation of ions at ambient conditions is a promising solution to these problems because the sample is easily accessible and the ion suppression effect is reduced significantly. A new method for rapid on-line detection of metabolic markers in complex biological samples is described here. It combines atmospheric pressure desorption sampling by a gentle stream of air or nitrogen with extractive electrospray ionization (EESI) and mass spectrometric analysis. The resulting mass spectral fingerprints are shown to be able to detect spoilage of meat even in the frozen (-20 degrees C) state and the contamination of spinach by E. coli, and to identify metabolites and contaminants on human skin within seconds, in an on-line and high-throughput fashion. Typical molecular markers are identified using MS/MS data and by comparison with reference compounds. Differences between closely related samples are easily visualized by using principal component analysis (PCA) of the mass spectra data. The detection limit achieved is 10 fg/cm2 (S/N = 3) for histamine on the surface of frozen meat. The technique reported here shows potential for more advanced applications in multiple disciplines, including food regulation, homeland security, in vivo metabolomics, and clinical diagnosis.
Collapse
Affiliation(s)
- Huanwen Chen
- Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093, Zürich, Switzerland
| | | | | |
Collapse
|
122
|
Chen H, Zheng J, Zhang X, Luo M, Wang Z, Qiao X. Surface desorption atmospheric pressure chemical ionization mass spectrometry for direct ambient sample analysis without toxic chemical contamination. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:1045-56. [PMID: 17605144 DOI: 10.1002/jms.1235] [Citation(s) in RCA: 112] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Ambient mass spectrometry, pioneered with desorption electrospray ionization (DESI) technique, is of increasing interest in recent years. In this study, a corona discharge ionization source is adapted for direct surface desorption chemical ionization of compounds on various surfaces at atmospheric pressure. Ambient air, with about 60% relative humidity, is used as a reagent to generate primary ions such as H(3)O(+), which is then directed to impact the sample surface for desorption and ionization. Under experimental conditions, protonated or deprotonated molecules of analytes present on various samples are observed using positive or negative corona discharge. Fast detection of trace amounts of analytes present in pharmaceutical preparations, viz foods, skins and clothes has been demonstrated without any sample pretreatment. Taking the advantage of the gasless setup, powder samples such as amino acids and mixtures of pharmaceutical preparations are rapidly analyzed. Impurities such as sudan dyes in tomato sauce are detected semiquantitatively. Molecular markers (e.g. putrescine) for meat spoilage are successfully identified from an artificially spoiled fish sample. Chemical warfare agent stimulants, explosives and herbicides are directly detected from the skin samples and clothing exposed to these compounds. This provides a detection limit of sub-pg (S/N > or = 3) range in MS2. Metabolites and consumed chemicals such as glucose are detected successfully from human skins. Conclusively, surface desorption atmospheric pressure chemical ionization (DAPCI) mass spectrometry, without toxic chemical contamination, detects various compounds in complex matrices, showing promising applications for analyses of human related samples.
Collapse
Affiliation(s)
- Huanwen Chen
- Applied Chemistry Department, East China Institute of Technology, Fuzhou 344000, P. R. China
| | | | | | | | | | | |
Collapse
|
123
|
Ratcliffe LV, Rutten FJM, Barrett DA, Whitmore T, Seymour D, Greenwood C, Aranda-Gonzalvo Y, Robinson S, McCoustra M. Surface Analysis under Ambient Conditions Using Plasma-Assisted Desorption/Ionization Mass Spectrometry. Anal Chem 2007; 79:6094-101. [PMID: 17628043 DOI: 10.1021/ac070109q] [Citation(s) in RCA: 159] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
A novel plasma-assisted desorption/ionization (PADI) method that can be coupled with atmospheric pressure sampling mass spectrometry to yield mass spectral information under ambient conditions of pressure and humidity from a range of surfaces without the requirement for sample preparation or additives is reported. PADI is carried out by generating a nonthermal plasma which interacts directly with the surface of the analyte. Desorption and ionization then occur at the surface, and ions are sampled by the mass spectrometer. The PADI technique is demonstrated and compared with desorption electrospray ionization (DESI) for the detection of active ingredients in a range of over-the-counter and prescription pharmaceutical formulations, including nonsterodial anti-inflammatory drugs (mefenamic acid, Ibugel, and ibuprofen), analgesics (paracetamol, Anadin Extra), and Beecham's "all in one" cold and flu remedy. PADI has also been successfully applied to the analysis of nicotine in tobacco and thiosulfates in garlic. PADI experiments have been performed using a prototype source interfaced with a Waters Platform LCZ single-quadrupole mass spectrometer with limited modifications and a Hiden Analytical HPR-60 molecular beam mass spectrometer (MBMS). The ability of PADI to rapidly detect active ingredients in pharmaceuticals without the need for prior sample preparation, solvents, or exposed high voltages demonstrates the potential of the technique for high-throughput screening in a pharmaceutical or forensic environment.
Collapse
Affiliation(s)
- Lucy V Ratcliffe
- Centre for Analytical Bioscience, School of Pharmacy, University of Nottingham, University Park, Nottingham, NG7 2RD, United Kingdom
| | | | | | | | | | | | | | | | | |
Collapse
|
124
|
Kauppila TJ, Talaty N, Kuuranne T, Kotiaho T, Kostiainen R, Cooks RG. Rapid analysis of metabolites and drugs of abuse from urine samples by desorption electrospray ionization-mass spectrometry. Analyst 2007; 132:868-75. [PMID: 17710261 DOI: 10.1039/b703524a] [Citation(s) in RCA: 91] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Urine samples obtained from drug abusers were screened for drugs of abuse and their metabolites using DESI-MS and the results obtained were compared to results obtained from GC-MS experiments. The detected analyte classes included amphetamines, opiates, cannabinoids and benzodiazepines. The compounds detected were codeine, morphine, oxymorphone, 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol, Delta(9)-tetrahydrocannabinol, alprazolam, temazepam, oxazepam, N-desmethyldiazepam (nordiazepam) and hydroxytemazepam. Identities of all the analytes were confirmed by tandem mass spectrometry, matching MS/MS spectra with authentic standard compounds. The concentrations of the analytes in the samples were obtained from semi-quantitative GC-MS studies and were in the range of 270-22,000 ng mL(-1). The analytes could be detected by DESI even after a hundred-fold dilution indicating that the sensitivity of DESI was more than adequate for this study. Selectivity in the DESI-MS measurements for different kinds of analytes could be increased further by optimizing the spray solvent composition: the use of an entirely aqueous solvent enhanced the signal of polar analytes, such as the benzodiazepines, whereas the use of a spray solvent with a high organic content increased the signal of less polar analytes, such as codeine and morphine.
Collapse
Affiliation(s)
- Tiina J Kauppila
- Department of Chemistry, 560 Oval Drive, Purdue University, West Lafayette, IN 47907-2084, USA
| | | | | | | | | | | |
Collapse
|
125
|
Wu W, Qiao C, Liang Z, Xu H, Zhao Z, Cai Z. Alkaloid profiling in crude and processed Strychnos nux-vomica seeds by matrix-assisted laser desorption/ionization-time of flight mass spectrometry. J Pharm Biomed Anal 2007; 45:430-6. [PMID: 17706394 DOI: 10.1016/j.jpba.2007.06.031] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2007] [Revised: 06/20/2007] [Accepted: 06/29/2007] [Indexed: 10/23/2022]
Abstract
Direct analysis of alkaloids in the tissues of crude and processed Strychnos nux-vomica seeds by MALDI-TOFMS was described. The alkaloid profiles of the herb drugs were obtained without the need of complicated sample preparation to avoid potential damage or change of the active components. Seed tissues that were optimally sliced to a thickness of 10-20 microm from the crude and processed Strychnos nux-vomica seeds as well as various parts of tissue such as endosperm and epidermis were analyzed on MALDI target plate after the matrix was directly applied onto the tissue surface. The obtained alkaloid profiles provided valuable information for the differentiation of crude and processed Strychnos nux-vomica seeds and for the explanation of the significantly different toxicity. Experimental results indicated that the direct MALDI-TOFMS analysis allowed rapid screening of the alkaloid components in Strychnos nux-vomica seeds.
Collapse
Affiliation(s)
- Wei Wu
- Department of Chemistry, Hong Kong Baptist University, Kowloon, Hong Kong SAR, China
| | | | | | | | | | | |
Collapse
|
126
|
Shin YS, Drolet B, Mayer R, Dolence K, Basile F. Desorption electrospray ionization-mass spectrometry of proteins. Anal Chem 2007; 79:3514-8. [PMID: 17394289 PMCID: PMC3176668 DOI: 10.1021/ac062451t] [Citation(s) in RCA: 120] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperature of heated capillary tube, incident and reflection angle, sheath gas pressure, and ESI voltage. Detection limits were obtained for all protein standards, and they were found to decrease with decreasing protein molecular mass: for cytochrome c (12.3 kDa) and lysozyme (14.3 kDa) a detection limit of 4 ng/mm2 was obtained; for apomyoglobin (16.9 kDa) 20 ng/mm2; for beta-lactoglobulin B (18.2 kDa) 50 ng/mm2; and for chymotrypsinogen A (25.6 kDa) 100 ng/mm2. The DESI-MS analysis of higher molecular mass proteins such as ovalbumin (44.4 kDa) and bovine serum albumin (66.4 kDa) yielded mass spectra of low signal-to-noise ratio, making their detection and molecular weight determination difficult. In this study, DESI-MS proved to be a rapid and robust method for accurate MW determination for proteins up to 17 kDa under ambient conditions. Finally, we demonstrated the DESI-MS detection of the bacteriophage MS2 capsid protein from crude samples with minimal sample preparation.
Collapse
Affiliation(s)
- Yong-Seung Shin
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Barbara Drolet
- Arthropod-Borne Animal Diseases Research Laboratory, ARS, USDA, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Richard Mayer
- Arthropod-Borne Animal Diseases Research Laboratory, ARS, USDA, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Kurt Dolence
- School of Pharmacy, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Franco Basile
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| |
Collapse
|
127
|
Justes DR, Talaty N, Cotte-Rodriguez I, Cooks RG. Detection of explosives on skin using ambient ionization mass spectrometry. Chem Commun (Camb) 2007:2142-4. [PMID: 17520116 DOI: 10.1039/b703655h] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Single nanogram amounts of the explosives TNT, RDX, HMX, PETN and their mixtures were detected and identified in a few seconds on the surface of human skin without any sample preparation by desorption electrospray ionization (DESI) using a spray solution of methanol-water doped with sodium chloride to form the chloride adducts with RDX, HMX, and PETN while TNT was examined as the radical anion and tandem mass spectrometry was used to confirm the identifications.
Collapse
Affiliation(s)
- Dina R Justes
- Department of Chemistry, 560 Oval Drive, Purdue University, West Lafayette, IN 47906, USA
| | | | | | | |
Collapse
|
128
|
Zhang S, Shin YS, Mayer R, Basile F. On-Probe Pyrolysis Desorption Electrospray Ionization (DESI) Mass Spectrometry for the Analysis of Non-Volatile Pyrolysis Products. JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS 2007; 80:353-359. [PMID: 19855854 PMCID: PMC2766082 DOI: 10.1016/j.jaap.2007.04.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
An on-probe pyrolyzer has been constructed and interfaced with Desorption Electrospray Ionization (DESI) Mass Spectrometry (MS) for the rapid analysis of non-volatile pyrolysis products. The detection and analysis of non-volatile pyrolysis products of peptides, proteins and the synthetic polymer poly(ethylene glycol) are demonstrated with this instrument. The on-probe pyrolyzer can be operated off-line or on-line with the DESI source and was interfaced with a tandem MS (MS/MS) instrument, which allowed for structure characterization of the non-volatile pyrolytic products. Advantages of this system are its simplicity and speed of analysis since the pyrolysis is performed in situ on the DESI source probe and hence, it avoids extraction steps and/or the use of matrices (e.g., as in MALDI-MS analyses).
Collapse
Affiliation(s)
- Shaofeng Zhang
- Department of Chemistry, University of Wyoming, 1000E. University Ave. (3838), Laramie, Wyoming, USA 82071
| | - Yong-Seung Shin
- Department of Chemistry, University of Wyoming, 1000E. University Ave. (3838), Laramie, Wyoming, USA 82071
| | - Richard Mayer
- USDA ABDRL, University of Wyoming, 1000E. University Ave. (3838), Laramie, Wyoming, USA 82071
| | - Franco Basile
- Department of Chemistry, University of Wyoming, 1000E. University Ave. (3838), Laramie, Wyoming, USA 82071
| |
Collapse
|
129
|
Dong J, Rezenom YH, Murray KK. Desorption electrospray ionization of aerosol particles. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:3995-4000. [PMID: 18000959 DOI: 10.1002/rcm.3294] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We have applied desorption electrospray ionization to aerosol particles. Ions were formed from aerosols by merging suspended dry particles with an electrospray of solvent in a modified ion trap mass spectrometer. Dry aerosol particles were generated using a fluidized bed powder disperser and directed toward the inlet of the mass spectrometer. A nanospray source was used to create a spray of solvent droplets directed at the inlet and at a right angle with respect to the aerosol. Ions generated by the interaction of the particles and electrospray were transferred into the ion trap mass spectrometer. Using this method, pure samples of caffeine and erythromycin A were analyzed. In addition, commonly available food and drug powders including instant cocoa powder, artificial sweetener and ibuprofen were analyzed.
Collapse
Affiliation(s)
- Jianan Dong
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| | | | | |
Collapse
|
130
|
Kaur-Atwal G, Weston DJ, Green PS, Crosland S, Bonner PLR, Creaser CS. Analysis of tryptic peptides using desorption electrospray ionisation combined with ion mobility spectrometry/mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:1131-8. [PMID: 17318928 DOI: 10.1002/rcm.2941] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.
Collapse
Affiliation(s)
- Gushinder Kaur-Atwal
- School of Biomedical and Natural Sciences, Interdisciplinary Biomedical Research Centre, Nottingham Trent University, Nottingham NG11 8NS, UK
| | | | | | | | | | | |
Collapse
|
131
|
Mulligan CC, MacMillan DK, Noll RJ, Cooks RG. Fast analysis of high-energy compounds and agricultural chemicals in water with desorption electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:3729-3736. [PMID: 17952889 DOI: 10.1002/rcm.3270] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Novel sampling and detection methods using desorption electrospray ionization (DESI) are examined in the detection of explosives (RDX, TNT, HMX, and TNB) and agricultural chemicals (atrazine, alachlor and acetochlor) from aqueous matrices and authentic contaminated groundwater samples. DESI allows analysis of solid and liquid compounds directly from surfaces of interest with little or no sample preparation. Significant savings in analysis time and sample preparation are realized. The methods investigated here include (i) immediate analysis of filter paper wetted with contaminated water samples without further sample preparation, (ii) rapid liquid-liquid extraction (LLE), and (iii) analyte extraction from contaminated groundwater samples on-site using solid-phase extraction (SPE) membranes, followed by direct DESI analysis of the membrane. The wetted filter paper experiment demonstrates the maximum sample throughput for DESI analysis of aqueous matrices but has inadequate sensitivity for some of these analytes. Both the LLE and the SPE methods have adequate sensitivity. The resulting SPE membranes and/or small volume solvent extracts produced in these experiments are readily transported to off-site facilities for direct analysis by DESI. This realizes a significant reduction in the costs of sample shipping compared with those for typical liter-sized samples of groundwater. Total analysis times for these preliminary DESI analyses are comparable with or shorter than those for GC/MS and limits of detection approach environmental action levels for these compounds while maintaining a modest relative standard deviation. Tandem mass spectrometric data is used to provide additional specificity as needed.
Collapse
|
132
|
Wu W, Liang Z, Zhao Z, Cai Z. Direct analysis of alkaloid profiling in plant tissue by using matrix-assisted laser desorption/ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2007; 42:58-69. [PMID: 17149797 DOI: 10.1002/jms.1138] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
A method for the direct determination of alkaloid profiling in plant tissues by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was developed. The alkaloid profiles of the herbs were obtained without the need for complicated sample preparation. Experimental results demonstrated that the direct MALDI-TOFMS analysis allowed rapid and reliable characterization of the components in plant tissues. Four commonly used Chinese medicinal herbs were studied, including Aconitum Carmichaeli Debx. (Fuzi in Chinese) and Processed Fuzi, for herb differentiation and explanation of the significant difference in their toxicities. The direct analysis method proved valuable for the preliminary study of plant component profiles. The rapid collection of information from the direct analysis on plant tissues could be valuable for supporting the discovery of new compounds and for the quality control of medicinal herbs.
Collapse
Affiliation(s)
- Wei Wu
- Department of Chemistry, Hong Kong Baptist University, Kowloon, Hong Kong SAR, China
| | | | | | | |
Collapse
|
133
|
Gu H, Chen H, Pan Z, Jackson AU, Talaty N, Xi B, Kissinger C, Duda C, Mann D, Raftery D, Cooks RG. Monitoring Diet Effects via Biofluids and Their Implications for Metabolomics Studies. Anal Chem 2007; 79:89-97. [PMID: 17194125 DOI: 10.1021/ac060946c] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The effect of diet on metabolites found in rat urine samples has been investigated using nuclear magnetic resonance (NMR) and a new ambient ionization mass spectrometry experiment, extractive electrospray ionization mass spectrometry (EESI-MS). Urine samples from rats with three different dietary regimens were readily distinguished using multivariate statistical analysis on metabolites detected by NMR and MS. To observe the effect of diet on metabolic pathways, metabolites related to specific pathways were also investigated using multivariate statistical analysis. Discrimination is increased by making observations on restricted compound sets. Changes in diet at 24-h intervals led to predictable changes in the spectral data. Principal component analysis was used to separate the rats into groups according to their different dietary regimens using the full NMR, EESI-MS data or restricted sets of peaks in the mass spectra corresponding only to metabolites found in the urea cycle and metabolism of amino groups pathway. By contrast, multivariate analysis of variance from the score plots showed that metabolites of purine metabolism obscure the classification relative to the full metabolite set. These results suggest that it may be possible to reduce the number of statistical variables used by monitoring the biochemical variability of particular pathways. It should also be possible by this procedure to reduce the effect of diet in the biofluid samples for such purposes as disease detection.
Collapse
Affiliation(s)
- Haiwei Gu
- Department of Physics, Purdue University, West Lafayette, Indiana 47907, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
134
|
Ifa DR, Gumaelius LM, Eberlin LS, Manicke NE, Cooks RG. Forensic analysis of inks by imaging desorption electrospray ionization (DESI) mass spectrometry. Analyst 2007; 132:461-7. [PMID: 17471393 DOI: 10.1039/b700236j] [Citation(s) in RCA: 140] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Desorption electrospray ionization mass spectrometry (DESI-MS) is employed in the forensic analysis of documents. Blue ballpoint pen inks applied to ordinary writing paper are examined under ambient conditions without any prior sample preparation. When coupled to an automated moving stage, two-dimensional molecular images are generated. Proof-of-principle experiments include characterization of a simulated forged number and examination of older written records. This application of DESI has advantages over extractive techniques in terms of speed and sample preservation. The effects of the desorbing solvent composition, in this case a mixture of methanol and water, and of flow rate, are evaluated. Results suggest that the solubility of the analyte (dyes Basic Blue 7, Basic Violet 3 and Solvent Blue 26) plays an important role in desorption from the paper surface.
Collapse
Affiliation(s)
- D R Ifa
- Purdue University, Department of Chemistry, West Lafayette, IN 47907, USA
| | | | | | | | | |
Collapse
|
135
|
Corso G, Paglia G, Garofalo D, D'Apolito O. Neutral loss analysis of amino acids by desorption electrospray ionization using an unmodified tandem quadrupole mass spectrometer. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:3777-3784. [PMID: 17972274 DOI: 10.1002/rcm.3280] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A new method to analyze free amino acids using desorption electrospray ionization (DESI) has been implemented. The method is based on the neutral loss mode determination of underivatized amino acids using a tandem quadrupole mass spectrometer equipped with an unmodified atmospheric interface. Qualitative and quantitative optimization of DESI parameters, including ESI voltage, solvent flow rate, angle of collection and incidence, gas flow and temperatures, was performed for amino acids detection. The parameters for DESI analysis were evaluated using a mixture of valine, leucine, methionine, phenylalanine and tyrosine standards. A few microliters of this mixture were deposited on a slide, dried and analyzed at a flow rate of 2 microL/min. The optimal ionization response was obtained using laboratory glass slides and an equivalent solution of water/methanol doped with 2% of formic acid. The method specificity was evaluated by comparing product ion spectra and neutral loss analysis of amino acids obtained either by DESI or by electrospray ionization flow injection analysis (ESI-FIA). To evaluate the quantitative response on amino acids analyzed by DESI, calibration curves were performed on amino acid standard solutions spiked with a fixed amount of labelled amino acids. The method was also employed to analyze free amino acids from blood spots, after a rapid solvent extraction without other sample pretreatment, from positive and negative subjects. The method enables one to analyze biological samples and to discriminate healthy subjects from patients affected by inherited metabolic diseases. The intrinsic high-throughput analysis of DESI represents an opportunity, because of its potential application in clinical chemistry, for the expanded screening of some inborn errors of metabolism.
Collapse
Affiliation(s)
- Gaetano Corso
- Clinical Biochemistry, Department of Biomedical Sciences, Faculty of Medicine, University of Foggia, Viale L. Pinto 1, 71100 Foggia, Italy.
| | | | | | | |
Collapse
|
136
|
Huang MZ, Hsu HJ, Wu CI, Lin SY, Ma YL, Cheng TL, Shiea J. Characterization of the chemical components on the surface of different solids with electrospray-assisted laser desorption ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:1767-75. [PMID: 17479981 DOI: 10.1002/rcm.3011] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
In this study we demonstrate that electrospray-assisted laser desorption ionization (ELDI) mass spectrometry (MS) can be used to rapidly characterize major chemical components on the surfaces of different solids under ambient conditions. The major chemical components in (a) dried milks with different fat contents, (b) different color-regions of a painting, (c) the thin coating on a compact disc, (d) drug tablets, and (e) porcine brain tissue were rapidly characterized as protonated molecules [M+H](+) or sodiated molecules [M+Na](+) by ELDI-MS with minimum sample pretreatment. The ionized ions of synthetic polymer and dye standards were detected directly from dried sample solutions using either positive or negative ion mode. Further structural information for the FD&C Red dye was obtained through tandem mass spectrometric (MS/MS) analysis using an ion trap mass analyzer attached to the ELDI source.
Collapse
Affiliation(s)
- Min-Zong Huang
- Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan
| | | | | | | | | | | | | |
Collapse
|
137
|
Song Y, Talaty N, Tao WA, Pan Z, Cooks RG. Rapid ambient mass spectrometric profiling of intact, untreated bacteria using desorption electrospray ionization. Chem Commun (Camb) 2006:61-3. [PMID: 17279261 DOI: 10.1039/b615724f] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Desorption electrospray ionization (DESI) allows the rapid acquisition of highly reproducible mass spectra from intact microorganisms under ambient conditions; application of principal component analysis to the data allows sub-species differentiation.
Collapse
Affiliation(s)
- Yishu Song
- Department of Chemistry, 560 Oval Drive, Purdue University, West Lafayette, IN 47906, USA
| | | | | | | | | |
Collapse
|
138
|
Nefliu M, Cooks RG, Moore C. Enhanced desorption ionization using oxidizing electrosprays. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2006; 17:1091-1095. [PMID: 16735130 DOI: 10.1016/j.jasms.2006.04.021] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2005] [Revised: 03/28/2006] [Accepted: 04/01/2006] [Indexed: 05/09/2023]
Abstract
A signal enhancement of two orders of magnitude was achieved when reactive desorption electrospray ionization (DESI) was used to investigate copper(II) dibutyl dithiocarbamate, Cu(II)(bu2dtc)2, found in a specialized polymer. Cu(II) was oxidized to Cu(III) during the DESI experiment by oxidants in the spray solvent. Such oxidants could be present or formed during electrospray (e.g., O2) or deliberately added to the spray solvent (this approach is called reactive DESI). When a strong oxidizing agent (e.g., iodine) was added to the spray solvent, the signal increased by two orders of magnitude relative to the pure solvent spray. The correlation between the standard reduction potential of the oxidant and the signal intensity and signal to noise ratio of the product ion for various reagents, was tested and discussed. The observed DESI enhancements in rates of oxidation are not observed in homogeneous solution. The major peaks in the collision induced dissociation (CID) spectrum of the complex ion Cu(III)(bu2dtc)2]+ were identified using isotopic distributions and MS3 data.
Collapse
Affiliation(s)
- Marcela Nefliu
- Department of Chemistry, Purdue University, 560 Oval Drive, 47907-2084, West Lafayette, IN
| | - R Graham Cooks
- Department of Chemistry, Purdue University, 560 Oval Drive, 47907-2084, West Lafayette, IN.
| | - Colin Moore
- Chemtura Corporation, Middlebury, Connecticut, USA
| |
Collapse
|
139
|
Pan Z, Gu H, Talaty N, Chen H, Shanaiah N, Hainline BE, Cooks RG, Raftery D. Principal component analysis of urine metabolites detected by NMR and DESI–MS in patients with inborn errors of metabolism. Anal Bioanal Chem 2006; 387:539-49. [PMID: 16821030 DOI: 10.1007/s00216-006-0546-7] [Citation(s) in RCA: 110] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2006] [Accepted: 05/11/2006] [Indexed: 10/24/2022]
Abstract
Urine metabolic profiles of patients with inborn errors of metabolism were examined with nuclear magnetic resonance (NMR) and desorption electrospray ionization mass spectrometry (DESI-MS) methods. Spectra obtained from the study of urine samples from individual patients with argininosuccinic aciduria (ASA), classic homocystinuria (HCY), classic methylmalonic acidemia (MMA), maple syrup urine disease (MSUD), phenylketonuria (PKU) and type II tyrosinemia (TYRO) were compared with six control patient urine samples using principal component analysis (PCA). Target molecule spectra were identified from the loading plots of PCA output and compared with known metabolic profiles from the literature and metabolite databases. Results obtained from the two techniques were then correlated to obtain a common list of molecules associated with the different diseases and metabolic pathways. The combined approach discussed here may prove useful in the rapid screening of biological fluids from sick patients and may help to improve the understanding of these rare diseases.
Collapse
Affiliation(s)
- Zhengzheng Pan
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907, USA
| | | | | | | | | | | | | | | |
Collapse
|
140
|
Van Berkel GJ, Kertesz V. Automated Sampling and Imaging of Analytes Separated on Thin-Layer Chromatography Plates Using Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2006; 78:4938-44. [PMID: 16841914 DOI: 10.1021/ac060690a] [Citation(s) in RCA: 95] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Modest modifications to the atmospheric sampling capillary of a commercial electrospray mass spectrometer and upgrades to an in-house-developed surface positioning control software package (HandsFree TLC/MS) were used to enable the automated sampling and imaging of analytes on and within large area surface substrates using desorption electrospray ionization mass spectrometry. Sampling and imaging of rhodamine dyes separated on TLC plates were used to illustrate some of the practical applications of this system. Examples are shown for user-defined spot sampling from separated bands on a TLC plate (one or multiple spots), scanning of a complete development lane (one or multiple lanes), or imaging of analyte bands in a development lane (i.e., multiple lane scans with close spacing). The post data acquisition processing and data display aspects of the software system are also discussed.
Collapse
Affiliation(s)
- Gary J Van Berkel
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131, USA.
| | | |
Collapse
|
141
|
Abstract
A recent innovation in mass spectrometry is the ability to record mass spectra on ordinary samples, in their native environment, without sample preparation or preseparation by creating ions outside the instrument. In desorption electrospray ionization (DESI), the principal method described here, electrically charged droplets are directed at the ambient object of interest; they release ions from the surface, which are then vacuumed through the air into a conventional mass spectrometer. Extremely rapid analysis is coupled with high sensitivity and high chemical specificity. These characteristics are advantageously applied to high-throughput metabolomics, explosives detection, natural products discovery, and biological tissue imaging, among other applications. Future possible uses of DESI for in vivo clinical analysis and its adaptation to portable mass spectrometers are described.
Collapse
Affiliation(s)
- R Graham Cooks
- Purdue University, Department of Chemistry, West Lafayette, IN 47907, USA.
| | | | | | | |
Collapse
|
142
|
Chen H, Pan Z, Talaty N, Raftery D, Cooks RG. Combining desorption electrospray ionization mass spectrometry and nuclear magnetic resonance for differential metabolomics without sample preparation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1577-84. [PMID: 16628593 DOI: 10.1002/rcm.2474] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Desorption electrospray ionization mass spectrometry (DESI-MS) and nuclear magnetic resonance (NMR) spectroscopy are used to provide data on urine examined without sample preparation to allow differentiation between diseased (lung cancer) and healthy mice. Principal component analysis (PCA) is used to shortlist compounds with potential for biomarker screening which are responsible for significant differences between control urine samples and samples from diseased animals. Similar PCA score plots have been achieved by DESI-MS and NMR, using a subset of common detected metabolites. The common compounds detected by DESI and NMR have the same changes in sign of their concentrations thereby indicating the usefulness of corroborative analytical methods. The effects of different solvents and surfaces on the DESI mass spectra are also evaluated and optimized. Over 80 different metabolites were successfully identified by DESI-MS and tandem mass spectrometry experiments, with no prior sample preparation.
Collapse
Affiliation(s)
- Huanwen Chen
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | | | | | | |
Collapse
|
143
|
Williams JP, Patel VJ, Holland R, Scrivens JH. The use of recently described ionisation techniques for the rapid analysis of some common drugs and samples of biological origin. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1447-56. [PMID: 16586475 DOI: 10.1002/rcm.2470] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Three ionisation techniques that require no sample preparation or extraction prior to mass analysis have been used for the rapid analysis of pharmaceutical tablets and ointments. These methods were (i) the novel direct analysis in real time (DART), (ii) desorption electrospray ionisation (DESI), and (iii) desorption atmospheric pressure chemical ionisation (DAPCI). The performance of the three techniques was investigated for a number of common drugs. Significant differences between these approaches were observed. For compounds of moderate to low polarity DAPCI produced more effective ionisation. Accurate DESI and DAPCI tandem mass spectra were obtained and these greatly enhance the selectivity and information content of the experiment. The detection from human skin of the active ingredients from ointments is reported together with the detection of ibuprofen metabolites in human urine.
Collapse
Affiliation(s)
- Jonathan P Williams
- Department of Biological Sciences, University of Warwick, Gibbet Hill Rd, Coventry CV4 7AL, UK.
| | | | | | | |
Collapse
|
144
|
Hu Q, Talaty N, Noll RJ, Cooks RG. Desorption electrospray ionization using an Orbitrap mass spectrometer: Exact mass measurements on drugs and peptides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:3403-8. [PMID: 17051609 DOI: 10.1002/rcm.2757] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Desorption electrospray ionization (DESI) is implemented on an Orbitrap mass spectrometer. The ion source is described and applications which utilize the high-resolution capabilities of the Orbitrap are emphasized, including the characterization of peptides and active ingredients in pharmaceutical tablets. Measurements are made in less than 1 s at a resolution of 60,000. The implications of the data for the mechanisms of DESI are discussed.
Collapse
Affiliation(s)
- Qizhi Hu
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | | | | |
Collapse
|
145
|
Bereman MS, Nyadong L, Fernandez FM, Muddiman DC. Direct high-resolution peptide and protein analysis by desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:3409-11. [PMID: 17051610 DOI: 10.1002/rcm.2759] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We report the first coupling of a desorption electrospray ionization (DESI) ion source to Fourier transform ion cyclotron resonance mass spectrometry (ESI-FT-ICR-MS) for high-resolution protein analysis. The DESI FT-ICR-MS source design is described in detail along with preliminary data obtained on peptides and proteins ranging from 1 to 5.7 kDa.
Collapse
Affiliation(s)
- Michael S Bereman
- W M Keck FT-ICR Mass Spectrometry Laboratory, Department of Chemistry, North Carolina State University, Raleigh, NC 27695, USA
| | | | | | | |
Collapse
|
146
|
Kauppila TJ, Wiseman JM, Ketola RA, Kotiaho T, Cooks RG, Kostiainen R. Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:387-92. [PMID: 16381061 DOI: 10.1002/rcm.2304] [Citation(s) in RCA: 65] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The performance of desorption electrospray ionization (DESI) in the analysis of a group of pharmaceuticals and their glucuronic acid conjugates is reported. The suitability of different sprayer solvents and different surfaces was examined. In the positive ion mode, water/methanol/trifluoroacetic acid performed best, whereas, in the negative ion mode, water/methanol/ammonium hydroxide was found to be the most suitable spray solvent. Of the surfaces investigated, polymethylmethacrylate (PMMA) was found to give the best performance in terms of sensitivity. Spray solution flow rate and the distance of the sprayer tip from the surface were also found to have significant effects on the signal intensity. Analytes with basic groups efficiently formed the corresponding protonated molecules in the positive ion mode, whereas acidic analytes, such as the glucuronic acid conjugates, formed intense signals due to the deprotonated molecules in the negative ion mode. Ionization of neutral compounds was less efficient and in many cases it was achieved through adduct formation with simple anions or cations.
Collapse
Affiliation(s)
- Tiina J Kauppila
- Department of Chemistry, Purdue University, West Lafayette, IN 47907-2084, USA
| | | | | | | | | | | |
Collapse
|
147
|
Kauppila TJ, Talaty N, Salo PK, Kotiaho T, Kostiainen R, Cooks RG. New surfaces for desorption electrospray ionization mass spectrometry: porous silicon and ultra-thin layer chromatography plates. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:2143-50. [PMID: 16773669 DOI: 10.1002/rcm.2566] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The performance of nanoporous silicon (pSi) and ultra-thin layer chromatography (UTLC) plates as surfaces for desorption electrospray ionization (DESI) was compared with that of polymethyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE), both popular surfaces in previous DESI studies. The limits of detection (LODs) and other analytical characteristics for six different test compounds were determined using all four surfaces. The LODs for the compounds were in the fmol-pmol (pg-ng) range. The LODs with the pSi surface were further improved for each of the compounds when heat was applied to the surface during sample application which gave LODs as low as or lower than those achieved with PMMA and PTFE. The UTLC plates were successfully used as a rapid means of chromatographic separation prior to DESI-MS analysis. Another advantage achieved using the newer pSi and UTLC surfaces was increased speed of analysis, associated with drying of solution-phase samples. This took place immediately at the UTLC surface and it could be achieved rapidly by gently heating the pSi surface. The presence of salts in the sample did not cause suppression of the analyte signal with any of the surfaces.
Collapse
Affiliation(s)
- Tiina J Kauppila
- Department of Chemistry, Purdue University, West Lafayette, IN 47907, USA
| | | | | | | | | | | |
Collapse
|
148
|
Mulligan CC, Talaty N, Cooks RG. Desorption electrospray ionization with a portable mass spectrometer: in situ analysis of ambient surfaces. Chem Commun (Camb) 2006:1709-11. [PMID: 16609779 DOI: 10.1039/b517357d] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Desorption electrospray ionization (DESI) is implemented on a portable mass spectrometer and used to demonstrate in situ detection of active ingredients in pharmaceutical preparations, alkaloids in plant tissues, explosives, chemical warfare agent simulants and agricultural chemicals from a variety of surfaces; air monitoring applications using DESI are also introduced.
Collapse
|