1
|
Finnegan RN, Quinn A, Booth J, Belous G, Hardcastle N, Stewart M, Griffiths B, Carroll S, Thwaites DI. Cardiac substructure delineation in radiation therapy - A state-of-the-art review. J Med Imaging Radiat Oncol 2024. [PMID: 38757728 DOI: 10.1111/1754-9485.13668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 04/29/2024] [Indexed: 05/18/2024]
Abstract
Delineation of cardiac substructures is crucial for a better understanding of radiation-related cardiotoxicities and to facilitate accurate and precise cardiac dose calculation for developing and applying risk models. This review examines recent advancements in cardiac substructure delineation in the radiation therapy (RT) context, aiming to provide a comprehensive overview of the current level of knowledge, challenges and future directions in this evolving field. Imaging used for RT planning presents challenges in reliably visualising cardiac anatomy. Although cardiac atlases and contouring guidelines aid in standardisation and reduction of variability, significant uncertainties remain in defining cardiac anatomy. Coupled with the inherent complexity of the heart, this necessitates auto-contouring for consistent large-scale data analysis and improved efficiency in prospective applications. Auto-contouring models, developed primarily for breast and lung cancer RT, have demonstrated performance comparable to manual contouring, marking a significant milestone in the evolution of cardiac delineation practices. Nevertheless, several key concerns require further investigation. There is an unmet need for expanding cardiac auto-contouring models to encompass a broader range of cancer sites. A shift in focus is needed from ensuring accuracy to enhancing the robustness and accessibility of auto-contouring models. Addressing these challenges is paramount for the integration of cardiac substructure delineation and associated risk models into routine clinical practice, thereby improving the safety of RT for future cancer patients.
Collapse
Affiliation(s)
- Robert N Finnegan
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia
| | - Alexandra Quinn
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - Jeremy Booth
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia
| | - Gregg Belous
- Australian e-Health Research Centre, Commonwealth Scientific and Industrial Research Organisation, Brisbane, Queensland, Australia
| | - Nicholas Hardcastle
- Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
- Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne, Victoria, Australia
| | - Maegan Stewart
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
- School of Health Sciences, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Brooke Griffiths
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - Susan Carroll
- Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, New South Wales, Australia
- School of Health Sciences, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - David I Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia
- Radiotherapy Research Group, Leeds Institute of Medical Research, St James's Hospital and University of Leeds, Leeds, UK
| |
Collapse
|
2
|
Whitmore L, Mackay RI, van Herk M, Korysko P, Farabolini W, Malyzhenkov A, Corsini R, Jones RM. CERN-based experiments and Monte-Carlo studies on focused dose delivery with very high energy electron (VHEE) beams for radiotherapy applications. Sci Rep 2024; 14:11120. [PMID: 38750131 PMCID: PMC11096185 DOI: 10.1038/s41598-024-60997-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 04/30/2024] [Indexed: 05/18/2024] Open
Abstract
Very High Energy Electron (VHEE) beams are a promising alternative to conventional radiotherapy due to their highly penetrating nature and their applicability as a modality for FLASH (ultra-high dose-rate) radiotherapy. The dose distributions due to VHEE need to be optimised; one option is through the use of quadrupole magnets to focus the beam, reducing the dose to healthy tissue and allowing for targeted dose delivery at conventional or FLASH dose-rates. This paper presents an in depth exploration of the focusing achievable at the current CLEAR (CERN Linear Electron Accelerator for Research) facility, for beam energies >200 MeV. A shorter, more optimal quadrupole setup was also investigated using the TOPAS code in Monte Carlo simulations, with dimensions and beam parameters more appropriate to a clinical situation. This work provides insight into how a focused VHEE radiotherapy beam delivery system might be achieved.
Collapse
Affiliation(s)
- L Whitmore
- Department of Physics and Astronomy, University of Manchester, Manchester, M13 9PL, UK
- The Cockcroft Institute of Science and Technology, Daresbury, UK
- Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, USA
| | - R I Mackay
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK
| | - M van Herk
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
- Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK
| | - P Korysko
- Department of Physics, University of Oxford, Oxford, UK
- CERN, 1211, Geneva 23, Switzerland
| | | | | | | | - R M Jones
- Department of Physics and Astronomy, University of Manchester, Manchester, M13 9PL, UK.
- The Cockcroft Institute of Science and Technology, Daresbury, UK.
| |
Collapse
|
3
|
Kim E, Park YK, Zhao T, Laugeman E, Zhao XN, Hao Y, Chung Y, Lee H. Image quality characterization of an ultra-high-speed kilovoltage cone-beam computed tomography imaging system on an O-ring linear accelerator. J Appl Clin Med Phys 2024; 25:e14337. [PMID: 38576183 PMCID: PMC11087174 DOI: 10.1002/acm2.14337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 01/23/2024] [Accepted: 03/06/2024] [Indexed: 04/06/2024] Open
Abstract
PURPOSE The quality of on-board imaging systems, including cone-beam computed tomography (CBCT), plays a vital role in image-guided radiation therapy (IGRT) and adaptive radiotherapy. Recently, there has been an upgrade of the CBCT systems fused in the O-ring linear accelerators called HyperSight, featuring a high imaging performance. As the characterization of a new imaging system is essential, we evaluated the image quality of the HyperSight system by comparing it with Halcyon 3.0 CBCT and providing benchmark data for routine imaging quality assurance. METHODS The HyperSight features ultra-fast scan time, a larger kilovoltage (kV) detector, a more substantial kV tube, and an advanced reconstruction algorithm. Imaging protocols in the two modes of operation, treatment mode with IGRT and the CBCT for planning (CBCTp) mode were evaluated and compared with Halcyon 3.0 CBCT. Image quality metrics, including spatial resolution, contrast resolution, uniformity, noise, computed tomography (CT) number linearity, and calibration error, were assessed using a Catphan and an electron density phantom and analyzed with TotalQA software. RESULTS HyperSight demonstrated substantial improvements in contrast-to-noise ratio and noise in both IGRT and CBCTp modes compared to Halcyon 3.0 CBCT. CT number calibration error of HyperSight CBCTp mode (1.06%) closely matches that of a full CT scanner (0.72%), making it suitable for adaptive planning. In addition, the advanced hardware of HyperSight, such as ultra-fast scan time (5.9 s) or 2.5 times larger heat unit capacity, enhanced the clinical efficiency in our experience. CONCLUSIONS HyperSight represented a significant advancement in CBCT imaging. With its image quality, CT number accuracy, and ultra-fast scans, HyperSight has a potential to transform patient care and treatment outcomes. The enhanced scan speed and image quality of HyperSight are expected to significantly improve the quality and efficiency of treatment, particularly benefiting patients.
Collapse
Affiliation(s)
- Euidam Kim
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
- Department of Nuclear EngineeringHanyang University College of EngineeringSeoulSouth Korea
| | - Yang Kyun Park
- Department of Radiation OncologyUniversity of Texas Southwestern Medical CenterDallasTexasUSA
| | - Tianyu Zhao
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
| | - Eric Laugeman
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
| | - Xiaodong Neo Zhao
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
| | - Yao Hao
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
| | - Yoonsun Chung
- Department of Nuclear EngineeringHanyang University College of EngineeringSeoulSouth Korea
| | - Hugh Lee
- Department of Radiation OncologyWashington University in St Louis School of MedicineSt LouisMissouriUSA
| |
Collapse
|
4
|
Pei J, Yan Y, Jayaraman S, Rajagopal P, Natarajan PM, Umapathy VR, Gopathy S, Roy JR, Sadagopan JC, Thalamati D, Palanisamy CP, Mironescu M. A review on advancements in the application of starch-based nanomaterials in biomedicine: Precision drug delivery and cancer therapy. Int J Biol Macromol 2024; 265:130746. [PMID: 38467219 DOI: 10.1016/j.ijbiomac.2024.130746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 03/01/2024] [Accepted: 03/07/2024] [Indexed: 03/13/2024]
Abstract
The burgeoning field of starch-based nanomaterials in biomedical applications has perceived notable progressions, with a particular emphasis on their pivotal role in precision drug delivery and the inhibition of tumor growth. The complicated challenges in current biomedical research require innovative approaches for improved therapeutic outcomes, prompting an exploration into the possible of starch-based nanomaterials. The conceptualization of this review emerged from recognizing the need for a comprehensive examination of the structural attributes, versatile properties, and mechanisms underlying the efficiency of starch-based nanomaterials in inhibiting tumor growth and enabling targeted drug delivery. This review delineates the substantial growth in utilizing starch-based nanomaterials, elucidating their small size, high surface-volume ratio, and biocompatibility, predominantly emphasizing their possible to actively recognize cancer cells, deliver anticancer drugs, and combat tumors efficiently. The investigation of these nanomaterials encompasses to improving biocompatibility and targeting specific tissues, thereby contributing to the evolving landscape of precision medicine. The review accomplishes by highlighting the auspicious strategies and modern developments in the field, envisioning a future where starch-based nanomaterials play a transformative role in molecular nanomaterials, evolving biomedical sciences. The translation of these advancements into clinical applications holds the potential to revolutionize targeted drug delivery and expand therapeutic outcomes in the realm of precision medicine.
Collapse
Affiliation(s)
- JinJin Pei
- Qinba State Key Laboratory of Biological Resources and Ecological Environment, 2011 QinLing-Bashan Mountains Bioresources Comprehensive Development C. I. C, Shaanxi Province Key Laboratory of Bio-Resources, College of Bioscience and Bioengineering, Shaanxi University of Technology, Hanzhong 723001, China
| | - Yuqiang Yan
- Department of anaesthesia, Xi'an Central Hospital, No. 161, West 5th Road, Xincheng District, Xi'an 710003, China
| | - Selvaraj Jayaraman
- Centre of Molecular Medicine and Diagnostics (COMManD), Department of Biochemistry, Saveetha Dental College & Hospital, Saveetha Institute of Medical & Technical Sciences, Saveetha University, Chennai 600077, India
| | - Ponnulakshmi Rajagopal
- Central Research Laboratory, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education and Research (Deemed to be University), Chennai-600 095, India
| | - Prabhu Manickam Natarajan
- Department of Clinical Sciences, Center of Medical and Bio-allied Health Sciences and Research, College of Dentistry, Ajman University, Ajman, United Arab Emirates
| | - Vidhya Rekha Umapathy
- Department of Public Health Dentistry, Thai Moogambigai Dental College and Hospital, Chennai-600107, India
| | - Sridevi Gopathy
- Department of Physiology, SRM Dental College, Ramapuram campus, Chennai 600089, India
| | - Jeane Rebecca Roy
- Department of Anatomy, Bhaarath Medical College and hospital, Bharath Institute of Higher Education and Research (BIHER), Chennai, Tamil Nadu 600 073, India
| | - Janaki Coimbatore Sadagopan
- Department of Anatomy, Bhaarath Medical College and hospital, Bharath Institute of Higher Education and Research (BIHER), Chennai, Tamil Nadu 600 073, India
| | | | - Chella Perumal Palanisamy
- Department of Chemical Technology, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
| | - Monica Mironescu
- Faculty of Agricultural Sciences Food Industry and Environmental Protection, Lucian Blaga University of Sibiu, Sibiu 550024, Romania.
| |
Collapse
|
5
|
Feng Z, Sun E, China D, Huang X, Hooshangnejad H, Gonzalez EA, Bell MAL, Ding K. Enhancing Image-Guided Radiation Therapy for Pancreatic Cancer: Utilizing Aligned Peak Response Beamforming in Flexible Array Transducers. Cancers (Basel) 2024; 16:1244. [PMID: 38610923 PMCID: PMC11011135 DOI: 10.3390/cancers16071244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/28/2024] [Accepted: 03/08/2024] [Indexed: 04/14/2024] Open
Abstract
To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.
Collapse
Affiliation(s)
- Ziwei Feng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
| | - Edward Sun
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Computer Science, University of California, Los Angeles, CA 90095, USA
| | - Debarghya China
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Xinyue Huang
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Hamed Hooshangnejad
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
| | - Eduardo A. Gonzalez
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
| | - Muyinatu A. Lediju Bell
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD 21218, USA; (E.A.G.); (M.A.L.B.)
- Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (D.C.); (X.H.)
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA; (Z.F.); (E.S.); (H.H.)
| |
Collapse
|
6
|
de Mol van Otterloo S, Westerhoff J, Leer T, Rutgers R, Meijers L, Daamen L, Intven M, Verkooijen H. Patient expectation and experience of MR-guided radiotherapy using a 1.5T MR-Linac. Tech Innov Patient Support Radiat Oncol 2024; 29:100224. [PMID: 38162695 PMCID: PMC10755768 DOI: 10.1016/j.tipsro.2023.100224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 10/19/2023] [Accepted: 11/21/2023] [Indexed: 01/03/2024] Open
Abstract
Background and Purpose Online adaptive MR-guided radiotherapy (MRgRT) is a relatively new form of radiotherapy treatment, delivered using a MR-Linac. It is unknown what patients expect from this treatment and whether these expectations are met. This study evaluates whether patients' pre-treatment expectations of MRgRT are met and reports patients' on-table experience on a 1.5 T MR-Linac. Materials and methods All patients treated on the MR-Linac from November 2020 until April 2021, were eligible for inclusion. Patient expectation and experience were captured through questionnaires before, during, and three months after treatment. The on-table experience questionnaire included patient' physical and psychological coping. Patient-expected side effects, participation in daily and social activity, disease outcome and, disease related symptoms were compared to post-treatment experience. Results We included 113 patients who were primarily male (n = 100, 89 %), with a median age of 69 years (range 52-90). For on-table experience, ninety percent of patients (strongly) agreed to feeling calm during their treatment. Six and eight percent of patients found the treatment position or bed uncomfortable respectively. Twenty-eight percent of patients felt tingling sensations during treatment. After treatment, 79 % of patients' expectations were met. Most patients experienced an (better than) expected level of side effects (75 %), participation in daily- (83 %) and social activity (86 %) and symptoms (78 %). However, 33 % expected more treatment efficacy than experienced. Conclusion Treatment on the 1.5 T MR-Linac is well tolerated and meets patient expectations. Despite the fact that some patients expected greater treatment efficacy and the frequent occurrence of tingling sensations during treatment, most patient experiences were comparable or better than previously expected.
Collapse
Affiliation(s)
- S.R. de Mol van Otterloo
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - J.M. Westerhoff
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - T. Leer
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - R.H.A. Rutgers
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - L.T.C. Meijers
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - L.A. Daamen
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - M.P.W. Intven
- Department of Radiation Oncology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, the Netherlands
| | - H.M. Verkooijen
- Division of Imaging, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
7
|
Mruma RM, Dharsee N, Malichewe CV, Kisukari JD, Yoram F, Myanza HS, Meena SS, Soko GF. Performance of an offline systematic error correction strategy in pediatric patients receiving adjuvant conformal radiotherapy for Wilm's tumor. PLoS One 2024; 19:e0297997. [PMID: 38363756 PMCID: PMC10871473 DOI: 10.1371/journal.pone.0297997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 01/16/2024] [Indexed: 02/18/2024] Open
Abstract
BACKGROUND Radiotherapy plays a key role as an adjuvant treatment in pediatric Wilm's tumor, improving both survival and quality of life. The success of radiotherapy depends on the precise delivery of radiation dose to the tumor while sparing radiosensitive structures in the vicinity of the tumor. Pediatric patients pose unique challenges in achieving accurate radiotherapy delivery due to their inability to understand instructions and the high radiosensitivity of their tissues. Thus, it is important to determine the optimum geometric verification strategy that will ensure accurate delivery of the prescribed target as specified in the patient's treatment plan. PURPOSE To evaluate the performance of an offline geometric correction strategy in ensuring accuracy and reproducibility during radiotherapy delivery in Wilm's tumor patients. MATERIAL AND METHODS The extended no-action level offline correction strategy was applied in the radiotherapy delivery of 45 Wilm's tumor patients. Gross errors from the first three fractions were used to calculate the mean errors which were then applied as offline correction factors. Mean errors among different groups were compared using a two-way analysis of variance (ANOVA) and Dunnett's pairwise comparisons. All statistical analyses and data visualization were performed using GraphPad Prism version 7 (Insight Partners, GraphPad Holdings, LLC). RESULTS A total of 45 patients were included in the study. In all three orthogonal directions, the recorded gross errors were significantly lower after the application of the systematic error corrections. Random errors were significantly larger in the longitudinal direction compared to lateral (mean difference = 0.28, p = 0.036) and vertical directions (mean difference = 0.37 cm, p = 0.003). Patients' age was a significant predictor of random errors whereby the magnitude of random error decreased with increasing age. CONCLUSION This study shows that the offline correction strategy used is effective in ensuring the accuracy of radiotherapy delivery in pediatric Wilm's tumor patients.
Collapse
Affiliation(s)
- Rashid Mussa Mruma
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Nazima Dharsee
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
- Ocean Road Cancer Institute, Dar es Salaam, Tanzania
| | - Christina Vallen Malichewe
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | - Jumaa Dachi Kisukari
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
- Ocean Road Cancer Institute, Dar es Salaam, Tanzania
| | - Furahini Yoram
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
| | | | | | - Geofrey Filbert Soko
- Department of Clinical Oncology, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
- Ocean Road Cancer Institute, Dar es Salaam, Tanzania
| |
Collapse
|
8
|
de Lima MR, Campbell DCDP, da Cunha-Madeira MR, Bomfim BCM, de Paula Ayres-Silva J. Animal Welfare in Radiation Research: The Importance of Animal Monitoring System. Vet Sci 2023; 10:651. [PMID: 37999474 PMCID: PMC10674294 DOI: 10.3390/vetsci10110651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 09/23/2023] [Accepted: 09/26/2023] [Indexed: 11/25/2023] Open
Abstract
Long-term research into radiation exposure significantly expanded following World War II, driven by the increasing number of individuals falling ill after the detonation of two atomic bombs in Japan. Consequently, researchers intensified their efforts to investigate radiation's effects using animal models and to study disease models that emerged post-catastrophe. As a result, several parameters have been established as essential in these models, encompassing radiation doses, regimens involving single or multiple irradiations, the injection site for transplantation, and the quantity of cells to be injected. Nonetheless, researchers have observed numerous side effects in irradiated animals, prompting the development of scoring systems to monitor these animals' well-being. The aim of this review is to delve into the historical context of using animals in radiation research and explore the ethical considerations related to animal welfare, which has become an increasingly relevant topic in recent years. These concerns have prompted research groups to adopt measures aimed at reducing animal suffering. Consequently, for animal welfare, the implementation of a scoring system for clinical and behavioral monitoring is essential. This represents one of the primary challenges and hurdles in radiation studies. It is concluded that implementing standardized criteria across all institutions is aimed at ensuring result reproducibility and fostering collaboration within the scientific community.
Collapse
Affiliation(s)
- Monique Ribeiro de Lima
- Center for Animal Experimentation, Oswaldo Cruz Institute, Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21041-250, Brazil; (M.R.d.L.)
| | - Daiani Cotrim de Paiva Campbell
- Center for Animal Experimentation, Oswaldo Cruz Institute, Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21041-250, Brazil; (M.R.d.L.)
| | | | - Barbara Cristina Marcollino Bomfim
- Laboratory of Experimental Medicine and Health, Oswaldo Cruz Institute, Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21041-250, Brazil
| | - Jackline de Paula Ayres-Silva
- Laboratory of Experimental Medicine and Health, Oswaldo Cruz Institute, Oswaldo Cruz Foundation (FIOCRUZ), Rio de Janeiro 21041-250, Brazil
| |
Collapse
|
9
|
Gebauer B, Pawelke J, Hoffmann A, Lühr A. Technical note: Experimental dosimetric characterization of proton pencil beam distortion in a perpendicular magnetic field of an in-beam MR scanner. Med Phys 2023; 50:7294-7303. [PMID: 37161832 DOI: 10.1002/mp.16448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 02/25/2023] [Accepted: 04/21/2023] [Indexed: 05/11/2023] Open
Abstract
BACKGROUND As it promises more precise and conformal radiation treatments, magnetic resonance imaging-integrated proton therapy (MRiPT) is seen as a next step in image guidance for proton therapy. The Lorentz force, which affects the course of the proton pencil beams, presents a problem for beam delivery in the presence of a magnetic field. PURPOSE To investigate the influence of the 0.32-T perpendicular magnetic field of an MR scanner on the delivery of proton pencil beams inside an MRiPT prototype system. METHODS An MRiPT prototype comprising of a horizontal pencil beam scanning beam line and an open 0.32-T MR scanner was used to evaluate the impact of the vertical magnetic field on proton beam deflection and dose spot pattern deformation. Three different proton energies (100, 150, and 220 MeV) and two spot map sizes (15 × 15 and 30 × 20 cm2 ) at four locations along the beam path without and with magnetic field were measured. Pencil-beam dose spots were measured using EBT3 films and a 2D scintillation detector. To study the magnetic field effects, a 2D Gaussian fit was applied to each individual dose spot to determine the central position( X , Y ) $(X,Y)$ , minimum and maximum lateral standard deviation (σ m i n $\sigma _{min}$ andσ m a x $\sigma _{max}$ ), orientation (θ), and the eccentricity (ε). RESULTS The dose spots were subjected to three simultaneous effects: (a) lateral horizontal beam deflection, (b) asymmetric trapezoidal deformation of the dose spot pattern, and (c) deformation and rotation of individual dose spots. The strongest effects were observed at a proton energy of 100 MeV with a horizontal beam deflection of 14-186 mm along the beam path. Within the central imaging field of the MR scanner, the maximum relative dose spot sizeσ m a x $\sigma _{max}$ decreased by up to 3.66%, whileσ m i n $\sigma _{min}$ increased by a maximum of 2.15%. The largest decrease and increase in the eccentricity of the dose spots were 0.08 and 0.02, respectively. The spot orientation θ was rotated by a maximum of 5.39°. At the higher proton energies, the same effects were still seen, although to a lesser degree. CONCLUSIONS The effect of an MRiPT prototype's magnetic field on the proton beam path, dose spot pattern, and dose spot form has been measured for the first time. The findings show that the impact of the MF must be appropriately recognized in a future MRiPT treatment planning system. The results emphasize the need for additional research (e.g., effect of magnetic field on proton beams with range shifters and impact of MR imaging sequences) before MRiPT applications can be employed to treat patients.
Collapse
Affiliation(s)
- Benjamin Gebauer
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
- Institute of Radiooncology-OncoRay, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
| | - Jörg Pawelke
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
- Institute of Radiooncology-OncoRay, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
| | - Aswin Hoffmann
- OncoRay-National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
- Institute of Radiooncology-OncoRay, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
- Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Armin Lühr
- Department of Physics, TU Dortmund University, Dortmund, Germany
| |
Collapse
|
10
|
Weerarathna IN, Kamble AR, Luharia A. Artificial Intelligence Applications for Biomedical Cancer Research: A Review. Cureus 2023; 15:e48307. [PMID: 38058345 PMCID: PMC10697339 DOI: 10.7759/cureus.48307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 11/05/2023] [Indexed: 12/08/2023] Open
Abstract
Artificial intelligence (AI) has rapidly evolved and demonstrated its potential in transforming biomedical cancer research, offering innovative solutions for cancer diagnosis, treatment, and overall patient care. Over the past two decades, AI has played a pivotal role in revolutionizing various facets of cancer clinical research. In this comprehensive review, we delve into the diverse applications of AI across the cancer care continuum, encompassing radiodiagnosis, radiotherapy, chemotherapy, immunotherapy, targeted therapy, surgery, and nanotechnology. AI has revolutionized cancer diagnosis, enabling early detection and precise characterization through advanced image analysis techniques. In radiodiagnosis, AI-driven algorithms enhance the accuracy of medical imaging, making it an invaluable tool for clinicians in the detection and assessment of cancer. AI has also revolutionized radiotherapy, facilitating precise tumor boundary delineation, optimizing treatment planning, and enabling real-time adjustments to improve therapeutic outcomes while minimizing collateral damage to healthy tissues. In chemotherapy, AI models have emerged as powerful tools for predicting patient responses to different treatment regimens, allowing for more personalized and effective strategies. In immunotherapy, AI analyzes genetic and imaging data to select ideal candidates for treatment and predict responses. Targeted therapy has seen great advancements with AI, aiding in the identification of specific molecular targets for tailored treatments. AI plays a vital role in surgery by offering real-time navigation and support, enhancing surgical precision. Moreover, the synergy between AI and nanotechnology promises the development of personalized nanomedicines, offering more efficient and targeted cancer treatments. While challenges related to data quality, interpretability, and ethical considerations persist, the future of AI in cancer research holds tremendous promise for improving patient outcomes through advanced and individualized care.
Collapse
Affiliation(s)
- Induni N Weerarathna
- Biomedical Sciences, School of Allied Health Sciences, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Aahash R Kamble
- Artificial Intelligence and Data Science, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Anurag Luharia
- Radiotherapy, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
11
|
Steiner E, Healy B, Baldock C. Dose from imaging at the time of treatment should be reduced. Phys Eng Sci Med 2023; 46:959-962. [PMID: 37436603 DOI: 10.1007/s13246-023-01298-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Affiliation(s)
- Elisabeth Steiner
- Institute for Radiation Oncology and Radiotherapy, LK Wiener Neustadt, Wiener Neustadt, Austria
| | - Brendan Healy
- Australian Clinical Dosimetry Service, Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Australia
| | - Clive Baldock
- Graduate Research School, Western Sydney University, Penrith, NSW, 2747, Australia.
| |
Collapse
|
12
|
Clark S, Pollard N, Brown E. An evaluation of isocentre shift magnitude and treatment site on image-guided radiation therapy online decision analysis times. J Med Radiat Sci 2023; 70:301-309. [PMID: 37000972 PMCID: PMC10500104 DOI: 10.1002/jmrs.671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 03/03/2023] [Indexed: 04/03/2023] Open
Abstract
INTRODUCTION The ability to capture more anatomical detail in cone-beam computed tomography (CBCT) imaging compared to kilovoltage (kV) and megavoltage (MV) imaging, has seen a documented shift towards CBCT image verification and staff adopting more extensive image analysis processes. The timeframe associated with assessing online CBCT images, termed the online decision analysis time, if drawn out, can affect treatment efficiency and accuracy. This study aimed to determine the current CBCT online decision analysis time at Radiation Oncology Princess Alexandra Ipswich Road (ROPAIR) and investigate the influence of isocentre shift magnitude and treatment site considerations on this timeframe. METHODS This retrospective clinical audit collected treatment parameters from 202 CBCT images over 2 treatment days. The online decision analysis time was calculated by subtracting the image acquisition timestamp from the image verification shift application timestamp. The quantitative data were analysed using mean, standard deviation, and range in the following categories: all CBCTs, CBCTs grouped by isocentre shift magnitude and CBCTs grouped by treatment site. Content analysis was performed on staff comments made during image analysis. RESULTS The average online decision analysis time was 2:37 ± 1:28 min. On average approximately, head and neck, spine and extremity treatment sites measured 1 min, pelvis, breast, and chest measured 2-3 min with abdomen measuring 4 min. Common categories reported in staff comments included anatomical changes, repositioning, and organs at risk size. CONCLUSION The results provide baseline online decision analysis times. Further refinement is required to determine if the image match method, treatment site considerations, and rotational discrepancies influence this timeframe.
Collapse
Affiliation(s)
- Sarah Clark
- Faculty of HealthQueensland University of TechnologyBrisbaneQueenslandAustralia
| | - Natalie Pollard
- Faculty of HealthQueensland University of TechnologyBrisbaneQueenslandAustralia
| | - Elizabeth Brown
- Faculty of HealthQueensland University of TechnologyBrisbaneQueenslandAustralia
- Radiation Oncology Princess Alexandra HospitalBrisbaneQueenslandAustralia
| |
Collapse
|
13
|
Umbarkar P, Kannan V, Anand VJ, Deshpande S, Hinduja R, Babu V, Naidu S, Jadhav O, Jejurkar A. A comparative study of rectal volume variation in patients with prostate cancer: A tertiary care center study. Radiography (Lond) 2023; 29:845-850. [PMID: 37399732 DOI: 10.1016/j.radi.2023.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 06/15/2023] [Accepted: 06/19/2023] [Indexed: 07/05/2023]
Abstract
INTRODUCTION Every day variations in rectal filling in prostate cancer radiotherapy can significantly alter the delivered dose distribution from what was intended. The goal of this study was to see if the time of treatment delivery affected the rectal filling. METHODS This is a retrospective study which included 50 patients with localized prostate cancer treated with volumetric modulated arc therapy (VMAT) to the primary and regional lymph nodes. Cone Beam Computed Tomography (CBCT) image-sets were done for all patient's daily setup verification. The radiation therapist contoured the rectum on all CBCT image sets. The rectal volumes delineated on CBCT and the planning CT image sets were compared. The change in rectal volumes between morning and afternoon treatments were calculated and compared. RESULTS A total of 1000 CBCT image sets were obtained on 50 patients in the morning and afternoon. The percentage variation of the CBCT rectal volumes over the planning CT scan was 16.57% in the AM group and 24.35% in the PM group. CONCLUSION The percentage change in rectal volume was significantly lesser in AM group compared to PM group and therefore morning treatments may result in dose distribution that is close to the intended dose distribution. IMPLICATIONS FOR PRACTICE In prostate cancer radiotherapy our study suggests that a simple technique of changing the time of treatment from afternoon to morning can help to reduce the rectal volume.
Collapse
Affiliation(s)
- P Umbarkar
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - V Kannan
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - V J Anand
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - S Deshpande
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - R Hinduja
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - V Babu
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - S Naidu
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - O Jadhav
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| | - A Jejurkar
- Radiotherapy Section, Dept. of Medicine., PD Hinduja National Hospital and Medical Research Centre, Mumbai, 400016, India.
| |
Collapse
|
14
|
Graeff C, Volz L, Durante M. Emerging technologies for cancer therapy using accelerated particles. PROGRESS IN PARTICLE AND NUCLEAR PHYSICS 2023; 131:104046. [PMID: 37207092 PMCID: PMC7614547 DOI: 10.1016/j.ppnp.2023.104046] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Cancer therapy with accelerated charged particles is one of the most valuable biomedical applications of nuclear physics. The technology has vastly evolved in the past 50 years, the number of clinical centers is exponentially growing, and recent clinical results support the physics and radiobiology rationale that particles should be less toxic and more effective than conventional X-rays for many cancer patients. Charged particles are also the most mature technology for clinical translation of ultra-high dose rate (FLASH) radiotherapy. However, the fraction of patients treated with accelerated particles is still very small and the therapy is only applied to a few solid cancer indications. The growth of particle therapy strongly depends on technological innovations aiming to make the therapy cheaper, more conformal and faster. The most promising solutions to reach these goals are superconductive magnets to build compact accelerators; gantryless beam delivery; online image-guidance and adaptive therapy with the support of machine learning algorithms; and high-intensity accelerators coupled to online imaging. Large international collaborations are needed to hasten the clinical translation of the research results.
Collapse
Affiliation(s)
- Christian Graeff
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Planckstraße 1, 64291 Darmstadt, Germany
- Technische Universität Darmstadt, Darmstadt, Germany
| | - Lennart Volz
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Planckstraße 1, 64291 Darmstadt, Germany
| | - Marco Durante
- GSI Helmholtzzentrum für Schwerionenforschung, Biophysics Department, Planckstraße 1, 64291 Darmstadt, Germany
- Technische Universität Darmstadt, Darmstadt, Germany
- Dipartimento di Fisica “Ettore Pancini”, University Federico II, Naples, Italy
| |
Collapse
|
15
|
Almansour H, Schick F, Nachbar M, Afat S, Fritz V, Thorwarth D, Zips D, Bertram F, Müller AC, Nikolaou K, Othman AE, Wegener D. Longitudinal monitoring of Apparent Diffusion Coefficient (ADC) in patients with prostate cancer undergoing MR-guided radiotherapy on an MR-Linac at 1.5 T: a prospective feasibility study. Radiol Oncol 2023; 57:184-190. [PMID: 37341194 DOI: 10.2478/raon-2023-0020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/30/2023] [Indexed: 06/22/2023] Open
Abstract
BACKGROUND Hybrid MRI linear accelerators (MR-Linac) might enable individualized online adaptation of radiotherapy using quantitative MRI sequences as diffusion-weighted imaging (DWI). The purpose of this study was to investigate the dynamics of lesion apparent diffusion coefficient (ADC) in patients with prostate cancer undergoing MR-guided radiation therapy (MRgRT) on a 1.5T MR-Linac. The ADC values at a diagnostic 3T MRI scanner were used as the reference standard. PATIENTS AND AND METHODS In this prospective single-center study, patients with biopsy-confirmed prostate cancer who underwent both an MRI exam at a 3T scanner (MRI3T) and an exam at a 1.5T MR-Linac (MRL) at baseline and during radiotherapy were included. Lesion ADC values were measured by a radiologist and a radiation oncologist on the slice with the largest lesion. ADC values were compared before vs. during radiotherapy (during the second week) on both systems via paired t-tests. Furthermore, Pearson correlation coefficient and inter-reader agreement were computed. RESULTS A total of nine male patients aged 67 ± 6 years [range 60 - 67 years] were included. In seven patients, the cancerous lesion was in the peripheral zone, and in two patients the lesion was in the transition zone. Inter-reader reliability regarding lesion ADC measurement was excellent with an intraclass correlation coefficient of (ICC) > 0.90 both at baseline and during radiotherapy. Thus, the results of the first reader will be reported. In both systems, there was a statistically significant elevation of lesion ADC during radiotherapy (mean MRL-ADC at baseline was 0.97 ± 0.18 × 10-3 mm2/s vs. mean MRL-ADC during radiotherapy 1.38 ± 0.3 × 10-3 mm2/s, yielding a mean lesion ADC elevation of 0.41 ± 0.20 × 10-3 mm2/s, p < 0.001). Mean MRI3T-ADC at baseline was 0.78 ± 0.165 × 10-3 mm2/s vs. mean MRI3T-ADC during radiotherapy 0.99 ± 0.175 × 10-3 mm2/s, yielding a mean lesion ADC elevation of 0.21 ± 0.96 × 10-3 mm2/s p < 0.001). The absolute ADC values from MRL were consistently significantly higher than those from MRI3T at baseline and during radiotherapy (p < = 0.001). However, there was a strong positive correlation between MRL-ADC and MRI3T-ADC at baseline (r = 0.798, p = 0.01) and during radiotherapy (r = 0.863, p = 0.003). CONCLUSIONS Lesion ADC as measured on MRL increased significantly during radiotherapy and ADC measurements of lesions on both systems showed similar dynamics. This indicates that lesion ADC as measured on the MRL may be used as a biomarker for evaluation of treatment response. In contrast, absolute ADC values as calculated by the algorithm of the manufacturer of the MRL showed systematic deviations from values obtained on a diagnostic 3T MRI system. These preliminary findings are promising but need large-scale validation. Once validated, lesion ADC on MRL might be used for real-time assessment of tumor response in patients with prostate cancer undergoing MR-guided radiation therapy.
Collapse
Affiliation(s)
- Haidara Almansour
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Tuebingen, Germany
| | - Fritz Schick
- Section for Experimental Radiology, Department of Radiology, Eberhard-Karls University, Tuebingen, Germany
| | - Marcel Nachbar
- Department of Radiation Oncology, Charité University Medicine Berlin, Berlin, Germany
- Section for Biomedical Physics, Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Tuebingen, Germany
| | - Victor Fritz
- Section for Experimental Radiology, Department of Radiology, Eberhard-Karls University, Tuebingen, Germany
| | - Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Daniel Zips
- Department of Radiation Oncology, Charité University Medicine Berlin, Berlin, Germany
- German Cancer Consortium (DKTK), Partner Site Tuebingen and German Cancer Research Center (DKFZ), Heidelberg, Germany
- Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
| | - Felix Bertram
- Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
| | - Arndt-Christian Müller
- Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
- Department of Radiation Oncology, RKH Klinikum Ludwigsburg, Ludwigsburg, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Tuebingen, Germany
- Cluster of Excellence iFIT (EXC 2180) "Image Guided and Functionally Instructed Tumor Therapies", University of Tuebingen, Tuebingen, Germany
| | - Ahmed E Othman
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls University, Tuebingen, Germany
- Department of Neuroradiology, University Medical Center Mainz, Mainz, Germany
| | - Daniel Wegener
- Department of Radiation Oncology, Eberhard-Karls University, Tuebingen, Germany
| |
Collapse
|
16
|
Pedretti S, De Santis MC, Vavassori V, Bortolato B, Colciago RR, Cagna E, Doino DP, Cocchi A, Gerardi MA, Alterio D, Magrini SM, Tonoli S. Image-guided radiotherapy (IGRT) in Lombardy, Italy: a survey by the Lombardy section of the Italian Association of Radiotherapy and Clinical Oncology (AIRO-Lombardy). Expert Rev Anticancer Ther 2023; 23:661-667. [PMID: 37129314 DOI: 10.1080/14737140.2023.2208864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
BACKGROUND Image-guided radiation therapy (IGRT) has changed clinical practice. We proposed a survey to radiotherapy centers in Lombardy to picture the current clinical practice of its use. RESEARCH DESIGN AND METHODS The survey consisted of 32 multiple-choice questions, divided into five topics: type of hospital, patients treated in 2019, number of LINACs; presence of protocols and staff involved in IGRT; IGRT in stereotaxis; IGRT in non-stereotactic treatments; availability of medical and technical staff. RESULTS Twenty-seven directors answered (77%). Most centers (74%) have produced protocols to ensure uniformity in the IGRT process. The most widely used IGRT modality (92%) is cone-beam CT. Daily IGRT control is favored for prostate (100%), head and neck (87%), and lung (78%) neoplasms. The resident doctors can always perform supervised IGRT matching in only six centers. Radiation therapists perform IGRT controls only for some sites in 12 cases (44%) and always in 9 cases (33%). Radiation oncologists are present in real time, in most cases. CONCLUSIONS Today, IGRT can be considered standard practice but at the price of more time-consuming procedures. A balance between a fully physician-controlled process and an increased role for specifically trained RTTs is actively being sought.
Collapse
Affiliation(s)
- Sara Pedretti
- Radiation Oncology Department, ASST Spedali Civili di Brescia, Brescia, Italy
| | - Maria Carmen De Santis
- Radiation Oncology Department, Istituto Nazionale per lo Studio e la cura dei tumori, Milano, Italy
| | - Vittorio Vavassori
- Humanitas Gavazzeni Hospital, Radiation Oncology Department, Bergamo, Italy
| | - Barbara Bortolato
- Radiation Oncology Department, ASST della Valle Olona, Busto Arsizio, Italy
| | - Riccardo Ray Colciago
- Radiation Oncology Department, Istituto Nazionale per lo Studio e la cura dei tumori, Milano, Italy
| | - Emanuela Cagna
- Radiation Oncology Department, ASST Lariana, Como, Italy
| | | | | | | | - Daniela Alterio
- Radiation Oncology Department, European Institue of Oncology, Milno, Italy
| | | | - Sandro Tonoli
- Radiation Oncology Department, ASST Cremona, Cremona, Italy
| |
Collapse
|
17
|
Ma CMC, Shan G, Hu W, Price RA, Chen L. A new target localization method for image-guided radiation therapy of prostate cancer. Phys Med 2023; 107:102550. [PMID: 36870203 DOI: 10.1016/j.ejmp.2023.102550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 01/24/2023] [Accepted: 02/18/2023] [Indexed: 03/06/2023] Open
Abstract
In imaged-guided radiation therapy (IGRT), target localization is usually done with rigid-body registration based on anatomy matching. Problems arise when the target volume can only be matched partially due to inter-fractional organ motion and deformation, resulting in deteriorated target coverage and critical structure sparing. A new target localization method is investigated in which the treatment target volume is aligned with the prescription isodose surface. Our study included 15 prostate patients previously treated with intensity-modulated radiation therapy (IMRT). Patient setup and target localization were performed using a CT-on-rails system before and after the IMRT treatment. IMRT plans were generated on the original simulation CTs (15) and the same MUs and leaf sequences were used to compute the dose distributions on post-treatment CTs (98) with the isocenter adjustments based on either anatomical structure matching or prescription isodose surface alignment. When patients were aligned with the traditional anatomy matching method, the dose to 95% of the CTV, D95, received 74.0 - 77.6 Gy and the minimum CTV dose, Dmin, was 61.9 - 71.6 Gy, respectively, in the cumulative dose distributions. The rectal dose-volume constraints were violated in 35.7% of the treatment fractions. When patients were aligned using the new localization method, the dose to 95% of the CTV, D95, received 74.0 - 78.2 Gy and the minimum CTV dose, Dmin, was 68.4 - 71.6 Gy, respectively, in the cumulative dose distributions. The rectal dose-volume constraints were violated in 17.3% of the treatment fractions. Traditional IGRT target localization based on anatomy matching is effective for population-based PTV margins but not ideal for those patients with large inter-fractional prostate rotation/deformation due to large rectal and bladder volume variation. The new method using the prescription isodose surface to align the target volume could improve the target coverage and rectal sparing for these patients, which can be implemented clinically to improve target dose delivery accuracy.
Collapse
Affiliation(s)
- C M Charlie Ma
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, United States.
| | - Guoping Shan
- Department of Radiation Physics, Zhejiang Key Lab of Radiation Oncology, Hangzhou, China
| | - Wei Hu
- Department of Radiation Oncology, Taizhou Central Hospital, Zhejiang, China
| | - Robert A Price
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, United States
| | - Lili Chen
- Department of Radiation Oncology, Fox Chase Cancer Center, Philadelphia, PA, United States
| |
Collapse
|
18
|
Wicker CA, Petery T, Dubey P, Wise-Draper TM, Takiar V. Improving Radiotherapy Response in the Treatment of Head and Neck Cancer. Crit Rev Oncog 2023; 27:73-84. [PMID: 36734873 DOI: 10.1615/critrevoncog.2022044635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The application of radiotherapy to the treatment of cancer has existed for over 100 years. Although its use has cured many, much work remains to be done to minimize side effects, and in-field tumor recurrences. Resistance of the tumor to a radiation-mediated death remains a complex issue that results in local recurrence and significantly decreases patient survival. Here, we review mechanisms of radioresistance and selective treatment combinations that improve the efficacy of the radiation that is delivered. Further investigation into the underlying mechanisms of radiation resistance is warranted to develop not just novel treatments, but treatments with improved safety profiles relative to current radiosensitizers. This review is written in memory and honor of Dr. Peter Stambrook, an avid scientist and thought leader in the field of DNA damage and carcinogenesis, and a mentor and advocate for countless students and faculty.
Collapse
Affiliation(s)
- Christina A Wicker
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, OH 45219
| | - Taylor Petery
- College of Medicine, University, of Cincinnati College of Medicine, Cincinnati, OH, 45267
| | - Poornima Dubey
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, OH 45219
| | | | - Vinita Takiar
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, OH 45219; Department of Radiation Oncology, Cincinnati Veteran's Affair Medical Center, Cincinnati, OH 45220
| |
Collapse
|
19
|
Thorwarth D. Clinical use of positron emission tomography for radiotherapy planning - Medical physics considerations. Z Med Phys 2023; 33:13-21. [PMID: 36272949 PMCID: PMC10068574 DOI: 10.1016/j.zemedi.2022.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 08/17/2022] [Accepted: 09/21/2022] [Indexed: 11/06/2022]
Abstract
PET/CT imaging plays an increasing role in radiotherapy treatment planning. The aim of this article was to identify the major use cases and technical as well as medical physics challenges during integration of these data into treatment planning. Dedicated aspects, such as (i) PET/CT-based radiotherapy simulation, (ii) PET-based target volume delineation, (iii) functional avoidance to optimized organ-at-risk sparing and (iv) functionally adapted individualized radiotherapy are discussed in this article. Furthermore, medical physics aspects to be taken into account are summarized and presented in form of check-lists.
Collapse
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany; German Cancer Consortium (DKTK), partner site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany.
| |
Collapse
|
20
|
Tran A, Desai S, Mraz Robinson D. From ancient Egypt to the dermatologic office: An overview of skin substitutes and modern-day applications in dermatologic surgery. Health Sci Rep 2023; 6:e1067. [PMID: 36694835 PMCID: PMC9843239 DOI: 10.1002/hsr2.1067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/03/2023] [Indexed: 01/18/2023] Open
Abstract
Skin grafting (specifically xenografting) dates back to as early as 1500 before Christ (BC) in the Ebers papyrus, an Egyptian medical papyrus. In 1503, the use of human skin allograft was described in the manuscript of Branca of Sicily, and among the Hindu Tilemaker Caste approximately 2500-3000 years ago, surgeons repaired defects secondary to nose amputations of those who committed adultery and thievery. Over the years, many advancements in skin grafts/substitutes and their applications have propelled the field to focus on better graft survival, contracture prevention, cosmesis, and quality of life. We provide a general overview of skin substitutes (SS) with a particular focus on placental SS and their current applications in dermatologic surgery.
Collapse
Affiliation(s)
- Alison Tran
- Menter Dermatology Research InstituteBaylor University Medical CenterDallasTexasUSA,Heights DermatologyHoustonTexasUSA
| | | | - Deanne Mraz Robinson
- Modern DermatologyWestportConnecticutUSA,Yale School of MedicineDepartment of DermatologyNew HavenConnecticutUSA
| |
Collapse
|
21
|
Ternad I, Penninckx S, Lecomte V, Vangijzegem T, Conrard L, Lucas S, Heuskin AC, Michiels C, Muller RN, Stanicki D, Laurent S. Advances in the Mechanistic Understanding of Iron Oxide Nanoparticles' Radiosensitizing Properties. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:201. [PMID: 36616111 PMCID: PMC9823929 DOI: 10.3390/nano13010201] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 12/16/2022] [Accepted: 12/26/2022] [Indexed: 06/17/2023]
Abstract
Among the plethora of nanosystems used in the field of theranostics, iron oxide nanoparticles (IONPs) occupy a central place because of their biocompatibility and magnetic properties. In this study, we highlight the radiosensitizing effect of two IONPs formulations (namely 7 nm carboxylated IONPs and PEG5000-IONPs) on A549 lung carcinoma cells when exposed to 225 kV X-rays after 6 h, 24 h and 48 h incubation. The hypothesis that nanoparticles exhibit their radiosensitizing effect by weakening cells through the inhibition of detoxification enzymes was evidenced by thioredoxin reductase activity monitoring. In particular, a good correlation between the amplification effect at 2 Gy and the residual activity of thioredoxin reductase was observed, which is consistent with previous observations made for gold nanoparticles (NPs). This emphasizes that NP-induced radiosensitization does not result solely from physical phenomena but also results from biological events.
Collapse
Affiliation(s)
- Indiana Ternad
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
| | - Sebastien Penninckx
- Medical Physics Department, Institut Jules Bordet, Université Libre de Bruxelles (ULB), B-1070 Brussels, Belgium
| | - Valentin Lecomte
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
| | - Thomas Vangijzegem
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
| | - Louise Conrard
- Center for Microscopy and Molecular Imaging (CMMI), B-6041 Gosselies, Belgium
| | - Stéphane Lucas
- Namur Research Institute for Life Sciences (NARILIS), University of Namur, B-5000 Namur, Belgium
| | - Anne-Catherine Heuskin
- Namur Research Institute for Life Sciences (NARILIS), University of Namur, B-5000 Namur, Belgium
| | - Carine Michiels
- Namur Research Institute for Life Sciences (NARILIS), University of Namur, B-5000 Namur, Belgium
| | - Robert N. Muller
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
- Center for Microscopy and Molecular Imaging (CMMI), B-6041 Gosselies, Belgium
| | - Dimitri Stanicki
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
| | - Sophie Laurent
- General, Organic and Biomedical Chemistry Unit, NMR and Molecular Imaging Laboratory, University of Mons (UMONS), B-7000 Mons, Belgium
- Center for Microscopy and Molecular Imaging (CMMI), B-6041 Gosselies, Belgium
| |
Collapse
|
22
|
Park JA, Kim Y, Yang J, Choi BK, Katoch N, Park S, Hur YH, Kim JW, Kim HJ, Kim HC. Effects of Irradiation on Brain Tumors Using MR-Based Electrical Conductivity Imaging. Cancers (Basel) 2022; 15:cancers15010022. [PMID: 36612018 PMCID: PMC9817812 DOI: 10.3390/cancers15010022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 12/04/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022] Open
Abstract
Ionizing radiation delivers sufficient energy inside the human body to create ions, which kills cancerous tissues either by damaging the DNA directly or by creating charged particles that can damage the DNA. Recent magnetic resonance (MR)-based conductivity imaging shows higher sensitivity than other MR techniques for evaluating the responses of normal tissues immediately after irradiation. However, it is still necessary to verify the responses of cancer tissues to irradiation by conductivity imaging for it to become a reliable tool in evaluating therapeutic effects in clinical practice. In this study, we applied MR-based conductivity imaging to mouse brain tumors to evaluate the responses in irradiated and non-irradiated tissues during the peri-irradiation period. Absolute conductivities of brain tissues were measured to quantify the irradiation effects, and the percentage changes were determined to estimate the degree of response. The conductivity of brain tissues with irradiation was higher than that without irradiation for all tissue types. The percentage changes of tumor tissues with irradiation were clearly different than those without irradiation. The measured conductivity and percentage changes between tumor rims and cores to irradiation were clearly distinguished. The contrast of the conductivity images following irradiation may reflect the response to the changes in cellularity and the amounts of electrolytes in tumor tissues.
Collapse
Affiliation(s)
- Ji Ae Park
- Division of Applied RI, Korea Institute of Radiological and Medical Science, Seoul 01812, Republic of Korea
| | - Youngsung Kim
- Office of Strategic R&D Planning (MOTIE), Seoul 06152, Republic of Korea
| | - Jiung Yang
- Division of Applied RI, Korea Institute of Radiological and Medical Science, Seoul 01812, Republic of Korea
| | - Bup Kyung Choi
- Medical Science Research Institute, Kyung Hee University Hospital, Seoul 02447, Republic of Korea
| | - Nitish Katoch
- Medical Science Research Institute, Kyung Hee University Hospital, Seoul 02447, Republic of Korea
| | - Seungwoo Park
- Comprehensive Radiation Irradiation Center, Korea Institute of Radiological and Medical Science, Seoul 01812, Republic of Korea
| | - Young Hoe Hur
- Department of Hepato-Biliary-Pancreas Surgery, Chonnam National University Medical School, Gwangju 61469, Republic of Korea
| | - Jin Woong Kim
- Department of Radiology, Chosun University Hospital, Gwangju 61453, Republic of Korea
| | - Hyung Joong Kim
- Medical Science Research Institute, Kyung Hee University Hospital, Seoul 02447, Republic of Korea
| | - Hyun Chul Kim
- Department of Radiology, Chosun University Hospital, Gwangju 61453, Republic of Korea
- Correspondence:
| |
Collapse
|
23
|
Goodburn RJ, Philippens MEP, Lefebvre TL, Khalifa A, Bruijnen T, Freedman JN, Waddington DEJ, Younus E, Aliotta E, Meliadò G, Stanescu T, Bano W, Fatemi‐Ardekani A, Wetscherek A, Oelfke U, van den Berg N, Mason RP, van Houdt PJ, Balter JM, Gurney‐Champion OJ. The future of MRI in radiation therapy: Challenges and opportunities for the MR community. Magn Reson Med 2022; 88:2592-2608. [PMID: 36128894 PMCID: PMC9529952 DOI: 10.1002/mrm.29450] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Revised: 08/17/2022] [Accepted: 08/22/2022] [Indexed: 01/11/2023]
Abstract
Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs-at-risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.
Collapse
Affiliation(s)
- Rosie J. Goodburn
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | | | - Thierry L. Lefebvre
- Department of PhysicsUniversity of CambridgeCambridgeUnited Kingdom
- Cancer Research UK Cambridge Research InstituteUniversity of CambridgeCambridgeUnited Kingdom
| | - Aly Khalifa
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioCanada
| | - Tom Bruijnen
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtNetherlands
| | | | - David E. J. Waddington
- Faculty of Medicine and Health, Sydney School of Health Sciences, ACRF Image X InstituteThe University of SydneySydneyNew South WalesAustralia
| | - Eyesha Younus
- Department of Medical Physics, Odette Cancer CentreSunnybrook Health Sciences CentreTorontoOntarioCanada
| | - Eric Aliotta
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Gabriele Meliadò
- Unità Operativa Complessa di Fisica SanitariaAzienda Ospedaliera Universitaria Integrata VeronaVeronaItaly
| | - Teo Stanescu
- Department of Radiation Oncology, University of Toronto and Medical Physics, Princess Margaret Cancer CentreUniversity Health NetworkTorontoOntarioCanada
| | - Wajiha Bano
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Ali Fatemi‐Ardekani
- Department of PhysicsJackson State University (JSU)JacksonMississippiUSA
- SpinTecxJacksonMississippiUSA
- Department of Radiation OncologyCommunity Health Systems (CHS) Cancer NetworkJacksonMississippiUSA
| | - Andreas Wetscherek
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Uwe Oelfke
- Joint Department of PhysicsInstitute of Cancer Research and Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Nico van den Berg
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtNetherlands
| | - Ralph P. Mason
- Department of RadiologyUniversity of Texas Southwestern Medical CenterDallasTexasUSA
| | - Petra J. van Houdt
- Department of Radiation OncologyNetherlands Cancer InstituteAmsterdamNetherlands
| | - James M. Balter
- Department of Radiation OncologyUniversity of MichiganAnn ArborMichiganUSA
| | - Oliver J. Gurney‐Champion
- Imaging and Biomarkers, Cancer Center Amsterdam, Amsterdam UMCUniversity of AmsterdamAmsterdamNetherlands
| |
Collapse
|
24
|
Smith L, Kuncic Z, Byrne HL, Waddington D. Nanoparticles for MRI-guided radiation therapy: a review. Cancer Nanotechnol 2022. [DOI: 10.1186/s12645-022-00145-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AbstractThe development of nanoparticle agents for MRI-guided radiotherapy is growing at an increasing pace, with clinical trials now underway and many pre-clinical evaluation studies ongoing. Gadolinium and iron-oxide-based nanoparticles remain the most clinically advanced nanoparticles to date, although several promising candidates are currently under varying stages of development. Goals of current and future generation nanoparticle-based contrast agents for MRI-guided radiotherapy include achieving positive signal contrast on T1-weighted MRI scans, local radiation enhancement at clinically relevant concentrations and, where applicable, avoidance of uptake by the reticuloendothelial system. Exploiting the enhanced permeability and retention effect or the use of active targeting ligands on nanoparticle surfaces is utilised to promote tumour uptake. This review outlines the current status of promising nanoparticle agents for MRI-guided radiation therapy, including several platforms currently undergoing clinical evaluation or at various stages of the pre-clinical development process. Challenges facing nanoparticle agents and possible avenues for current and future development are discussed.
Collapse
|
25
|
Lavigne D, Ng SP, O’Sullivan B, Nguyen-Tan PF, Filion E, Létourneau-Guillon L, Fuller CD, Bahig H. Magnetic Resonance-Guided Radiation Therapy for Head and Neck Cancers. Curr Oncol 2022; 29:8302-8315. [PMID: 36354715 PMCID: PMC9689607 DOI: 10.3390/curroncol29110655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 10/25/2022] [Accepted: 10/28/2022] [Indexed: 11/06/2022] Open
Abstract
Despite the significant evolution of radiation therapy (RT) techniques in recent years, many patients with head and neck cancer still experience significant toxicities during and after treatments. The increased soft tissue contrast and functional sequences of magnetic resonance imaging (MRI) are particularly attractive in head and neck cancer and have led to the increasing development of magnetic resonance-guided RT (MRgRT). This approach refers to the inclusion of the additional information acquired from a diagnostic or planning MRI in radiation treatment planning, and now extends to online high-quality daily imaging generated by the recently developed MR-Linac. MRgRT holds numerous potentials, including enhanced baseline and planning evaluations, anatomical and functional treatment adaptation, potential for hypofractionation, and multiparametric assessment of response. This article offers a structured review of the current literature on these established and upcoming roles of MRI for patients with head and neck cancer undergoing RT.
Collapse
Affiliation(s)
- Danny Lavigne
- Department of Radiation Oncology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
| | - Sweet Ping Ng
- Department of Radiation Oncology, Olivia Newton-John Cancer Centre, Austin Health, Melbourne, VI 3084, Australia
| | - Brian O’Sullivan
- Department of Radiation Oncology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
| | - Phuc Felix Nguyen-Tan
- Department of Radiation Oncology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
| | - Edith Filion
- Department of Radiation Oncology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
| | - Laurent Létourneau-Guillon
- Department of Radiology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
| | - Clifton D. Fuller
- Department of Radiation Oncology, MD Anderson Cancer Center, University of Texas, Houston, TX 77030, USA
| | - Houda Bahig
- Department of Radiation Oncology, Centre Hospitalier de l’Université de Montréal, University of Montreal, Montreal, QC H2X 3E4, Canada
- Correspondence:
| |
Collapse
|
26
|
De Deene Y. Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D. Gels 2022; 8:gels8090599. [PMID: 36135311 PMCID: PMC9498652 DOI: 10.3390/gels8090599] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/07/2022] [Accepted: 09/10/2022] [Indexed: 12/22/2022] Open
Abstract
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of gel dosimeters is the Fricke gel dosimeters, which consist of a hydrogel with dissolved ferrous ions that oxidize upon exposure to ionizing radiation. The oxidation results in a change in the nuclear magnetic resonance (NMR) relaxation, which makes it possible to read out Fricke gel dosimeters by use of quantitative magnetic resonance imaging (MRI). The radiation-induced oxidation in Fricke gel dosimeters can also be visualized by adding an indicator such as xylenol orange. The second class of gel dosimeters is the radiochromic gel dosimeters, which also exhibit a color change upon irradiation but do not use a metal ion. These radiochromic gel dosimeters do not demonstrate a significant radiation-induced change in NMR properties. The third class is the polymer gel dosimeters, which contain vinyl monomers that polymerize upon irradiation. Polymer gel dosimeters are predominantly read out by quantitative MRI or X-ray CT. The accuracy of the dosimeters depends on both the physico-chemical properties of the gel dosimeters and on the readout technique. Many different gel formulations have been proposed and discussed in the scientific literature in the last three decades, and scanning methods have been optimized to achieve an acceptable accuracy for clinical dosimetry. More recently, with the introduction of the MR-Linac, which combines an MRI-scanner and a clinical linear accelerator in one, it was shown possible to acquire dose maps during radiation, but new challenges arise.
Collapse
Affiliation(s)
- Yves De Deene
- Liverpool & Macarthur Cancer Therapy Centres, Liverpool, NSW 1871, Australia; or
- Ingham Institute, Liverpool, NSW 2170, Australia
- School of Science, Western Sydney University, Penrith, NSW 2751, Australia
| |
Collapse
|
27
|
Macchia G, Casà C, Ferioli M, Lancellotta V, Pezzulla D, Pappalardi B, Laliscia C, Ippolito E, Di Muzio J, Huscher A, Tortoreto F, Boccardi M, Lazzari R, De Iaco P, Raspagliesi F, Gadducci A, Garganese G, Ferrandina G, Morganti AG, Tagliaferri L. Observational multicenter Italian study on vulvar cancer adjuvant radiotherapy (OLDLADY 1.2): a cooperation among AIRO Gyn, MITO and MaNGO groups. Radiol Med 2022; 127:1292-1302. [DOI: 10.1007/s11547-022-01538-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Accepted: 07/28/2022] [Indexed: 12/01/2022]
|
28
|
Castelluccia A, Mincarone P, Tumolo MR, Sabina S, Colella R, Bodini A, Tramacere F, Portaluri M, Leo CG. Economic Evaluations of Magnetic Resonance Image-Guided Radiotherapy (MRIgRT): A Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph191710800. [PMID: 36078513 PMCID: PMC9517760 DOI: 10.3390/ijerph191710800] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 08/17/2022] [Accepted: 08/20/2022] [Indexed: 05/06/2023]
Abstract
OBJECTIVES This review systematically summarizes the evidence on the economic impact of magnetic resonance image-guided RT (MRIgRT). METHODS We systematically searched INAHTA, MEDLINE, and Scopus up to March 2022 to retrieve health economic studies. Relevant data were extracted on study type, model inputs, modeling methods and economic results. RESULTS Five studies were included. Two studies performed a full economic assessment to compare the cost-effectiveness of MRIgRT with other forms of image-guided radiation therapy. One study performed a cost minimization analysis and two studies performed an activity-based costing, all comparing MRIgRT with X-ray computed tomography image-guided radiation therapy (CTIgRT). Prostate cancer was the target condition in four studies and hepatocellular carcinoma in one. Considering the studies with a full economic assessment, MR-guided stereotactic body radiation therapy was found to be cost effective with respect to CTIgRT or conventional or moderate hypofractionated RT, even with a low reduction in toxicity. Conversely, a greater reduction in toxicity is required to compete with extreme hypofractionated RT without MR guidance. CONCLUSIONS This review highlights the great potential of MRIgRT but also the need for further evidence, especially for late toxicity, whose reduction is expected to be the real added value of this technology.
Collapse
Affiliation(s)
- Alessandra Castelluccia
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Pierpaolo Mincarone
- Institute for Research on Population and Social Policies, National Research Council, 72100 Brindisi, Italy
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Correspondence: ; Tel.: +39-3289168745
| | - Maria Rosaria Tumolo
- Department of Biological and Environmental Sciences and Technology, University of Salento, 73100 Lecce, Italy
| | - Saverio Sabina
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Institute of Clinical Physiology, National Research Council, 73100 Lecce, Italy
| | - Riccardo Colella
- Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy
| | - Antonella Bodini
- Institute for Applied Mathematics and Information Technologies “E. Magenes”, National Research Council, 20133 Milan, Italy
| | - Francesco Tramacere
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Maurizio Portaluri
- Radiation Oncology, Department of Radiotherapy, Hospital “A. Perrino”, ASL Brindisi, 72100 Brindisi, Italy
| | - Carlo Giacomo Leo
- MOVE-Mentis s.r.l., 47522 Cesena, Italy
- Institute of Clinical Physiology, National Research Council, 73100 Lecce, Italy
| |
Collapse
|
29
|
D’Aviero A, Re A, Catucci F, Piccari D, Votta C, Piro D, Piras A, Di Dio C, Iezzi M, Preziosi F, Menna S, Quaranta F, Boschetti A, Marras M, Miccichè F, Gallus R, Indovina L, Bussu F, Valentini V, Cusumano D, Mattiucci GC. Clinical Validation of a Deep-Learning Segmentation Software in Head and Neck: An Early Analysis in a Developing Radiation Oncology Center. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19159057. [PMID: 35897425 PMCID: PMC9329735 DOI: 10.3390/ijerph19159057] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Revised: 07/12/2022] [Accepted: 07/20/2022] [Indexed: 02/01/2023]
Abstract
Background: Organs at risk (OARs) delineation is a crucial step of radiotherapy (RT) treatment planning workflow. Time-consuming and inter-observer variability are main issues in manual OAR delineation, mainly in the head and neck (H & N) district. Deep-learning based auto-segmentation is a promising strategy to improve OARs contouring in radiotherapy departments. A comparison of deep-learning-generated auto-contours (AC) with manual contours (MC) was performed by three expert radiation oncologists from a single center. Methods: Planning computed tomography (CT) scans of patients undergoing RT treatments for H&N cancers were considered. CT scans were processed by Limbus Contour auto-segmentation software, a commercial deep-learning auto-segmentation based software to generate AC. H&N protocol was used to perform AC, with the structure set consisting of bilateral brachial plexus, brain, brainstem, bilateral cochlea, pharyngeal constrictors, eye globes, bilateral lens, mandible, optic chiasm, bilateral optic nerves, oral cavity, bilateral parotids, spinal cord, bilateral submandibular glands, lips and thyroid. Manual revision of OARs was performed according to international consensus guidelines. The AC and MC were compared using the Dice similarity coefficient (DSC) and 95% Hausdorff distance transform (DT). Results: A total of 274 contours obtained by processing CT scans were included in the analysis. The highest values of DSC were obtained for the brain (DSC 1.00), left and right eye globes and the mandible (DSC 0.98). The structures with greater MC editing were optic chiasm, optic nerves and cochleae. Conclusions: In this preliminary analysis, deep-learning auto-segmentation seems to provide acceptable H&N OAR delineations. For less accurate organs, AC could be considered a starting point for review and manual adjustment. Our results suggest that AC could become a useful time-saving tool to optimize workload and resources in RT departments.
Collapse
Affiliation(s)
- Andrea D’Aviero
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Alessia Re
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Francesco Catucci
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Danila Piccari
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
- Correspondence:
| | - Claudio Votta
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
| | - Domenico Piro
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
| | - Antonio Piras
- UO Radioterapia Oncologica, Villa Santa Teresa, 90011 Bagheria, Italy;
| | - Carmela Di Dio
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Martina Iezzi
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Francesco Preziosi
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Sebastiano Menna
- Medical Physics, Mater Olbia Hospital, 07026 Sassari, Italy; (S.M.); (F.Q.); (D.C.)
| | | | - Althea Boschetti
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Marco Marras
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
| | - Francesco Miccichè
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
| | - Roberto Gallus
- Otolaryngology, Mater Olbia Hospital, 07026 Sassari, Italy;
| | - Luca Indovina
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
| | - Francesco Bussu
- Otolaryngology, Azienda Ospedaliero Universitaria di Sassari, 07100 Sassari, Italy;
- Dipartimento delle Scienze Mediche, Chirurgiche e Sperimentali, Università di Sassari, 07100 Sassari, Italy
| | - Vincenzo Valentini
- UOC Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Roma, Italy; (F.M.); (L.I.); (V.V.)
- Dipartimento di Scienze Radiologiche ed Ematologiche, Università Cattolica del Sacro Cuore, 00168 Roma, Italy
| | - Davide Cusumano
- Medical Physics, Mater Olbia Hospital, 07026 Sassari, Italy; (S.M.); (F.Q.); (D.C.)
| | - Gian Carlo Mattiucci
- Radiation Oncology, Mater Olbia Hospital, 07026 Olbia, Italy; (A.D.); (A.R.); (F.C.); (C.V.); (D.P.); (C.D.D.); (M.I.); (F.P.); (A.B.); (M.M.); (G.C.M.)
- Dipartimento di Scienze Radiologiche ed Ematologiche, Università Cattolica del Sacro Cuore, 00168 Roma, Italy
| |
Collapse
|
30
|
Tachibana H, Takahashi R, Kogure T, Nishiyama S, Kurosawa T. Practical dosimetry procedure of air kerma for kilovoltage X-ray imaging in radiation oncology using a 0.6-cc cylindrical ionization chamber with a cobalt absorbed dose-to-water calibration coefficient. Radiol Phys Technol 2022; 15:264-270. [PMID: 35829894 DOI: 10.1007/s12194-022-00665-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 11/25/2022]
Abstract
In this study, we implemented a practical dosimetry procedure of air kerma for kilovoltage X-ray beams using a 0.6-cc cylindrical ionization chamber, and validated the procedure with the accuracy of the measurements using the 0.6-cc chamber compared to the measurements using a 6-cc chamber and a semiconductor device. In addition, the kerma area products (KAPs) were compared with the dose reference levels of radiology. A modified air kerma formalism using a 0.6-cc cylindrical ionization chamber air kerma formalism with a cobalt absorbed dose-to-water calibration coefficient was implemented. Validation of the formalism showed good agreement between the 0.6-cc chamber and the 6-cc chamber (< 5%), and between the 0.6-cc chamber and the semiconductor device (< 2%) in the 60-120 kV range. The KAPs for four RO machines had difference factors of 0.04-15.4 and 0.01-4.1 from their median and maximum dose reference levels in radiology, respectively.
Collapse
Affiliation(s)
- Hidenobu Tachibana
- Radiation Safety and Quality Assurance Division, Hospital East, National Cancer Center, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 2778577, Japan.
- Particle Therapy Division, Exploratory Oncology Research and Clinical Trial Center, National Cancer Center, Chiba, 2778577, Japan.
| | - Ryo Takahashi
- Particle Therapy Division, Exploratory Oncology Research and Clinical Trial Center, National Cancer Center, Chiba, 2778577, Japan
- Radiation Safety and Quality Assurance Division, Hospital East, National Cancer Center, Chiba, 2778577, Japan
| | - Takayuki Kogure
- Department of Radiology, Chiba Tokushukai Hospital, Chiba, 2748503, Japan
| | - Shiro Nishiyama
- Department of Radiology, General Hospital, Saiseikai Kawaguchi, Saitama, 3328558, Japan
| | - Tomoyuki Kurosawa
- Particle Therapy Division, Exploratory Oncology Research and Clinical Trial Center, National Cancer Center, Chiba, 2778577, Japan
| |
Collapse
|
31
|
Kuah T, Vellayappan BA, Makmur A, Nair S, Song J, Tan JH, Kumar N, Quek ST, Hallinan JTPD. State-of-the-Art Imaging Techniques in Metastatic Spinal Cord Compression. Cancers (Basel) 2022; 14:cancers14133289. [PMID: 35805059 PMCID: PMC9265325 DOI: 10.3390/cancers14133289] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 12/23/2022] Open
Abstract
Metastatic Spinal Cord Compression (MSCC) is a debilitating complication in oncology patients. This narrative review discusses the strengths and limitations of various imaging modalities in diagnosing MSCC, the role of imaging in stereotactic body radiotherapy (SBRT) for MSCC treatment, and recent advances in deep learning (DL) tools for MSCC diagnosis. PubMed and Google Scholar databases were searched using targeted keywords. Studies were reviewed in consensus among the co-authors for their suitability before inclusion. MRI is the gold standard of imaging to diagnose MSCC with reported sensitivity and specificity of 93% and 97% respectively. CT Myelogram appears to have comparable sensitivity and specificity to contrast-enhanced MRI. Conventional CT has a lower diagnostic accuracy than MRI in MSCC diagnosis, but is helpful in emergent situations with limited access to MRI. Metal artifact reduction techniques for MRI and CT are continually being researched for patients with spinal implants. Imaging is crucial for SBRT treatment planning and three-dimensional positional verification of the treatment isocentre prior to SBRT delivery. Structural and functional MRI may be helpful in post-treatment surveillance. DL tools may improve detection of vertebral metastasis and reduce time to MSCC diagnosis. This enables earlier institution of definitive therapy for better outcomes.
Collapse
Affiliation(s)
- Tricia Kuah
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Correspondence: ; Tel.: +65-6779-5555
| | - Balamurugan A. Vellayappan
- Department of Radiation Oncology, National University Cancer Institute Singapore, National University Hospital, Singapore 119074, Singapore;
| | - Andrew Makmur
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - Shalini Nair
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
| | - Junda Song
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
| | - Jiong Hao Tan
- University Spine Centre, Department of Orthopaedic Surgery, National University Health System, 1E Lower Kent Ridge Road, Singapore 119228, Singapore; (J.H.T.); (N.K.)
| | - Naresh Kumar
- University Spine Centre, Department of Orthopaedic Surgery, National University Health System, 1E Lower Kent Ridge Road, Singapore 119228, Singapore; (J.H.T.); (N.K.)
| | - Swee Tian Quek
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| | - James Thomas Patrick Decourcy Hallinan
- Department of Diagnostic Imaging, National University Hospital, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore; (A.M.); (S.N.); (J.S.); (S.T.Q.); (J.T.P.D.H.)
- Department of Diagnostic Radiology, Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Drive, Singapore 117597, Singapore
| |
Collapse
|
32
|
Abstract
Gold nanoparticle (AuNPs)-mediated photothermal therapy (PTT) has attracted increasing attention both in laboratory research and clinical applications. Due to its easily-tuned properties of irradiation light and inside-out hyperthermia ability, it has demonstrated clear advantages in cancer therapy over conventional thermal ablation. Despite this great advancement, the therapeutic efficacy of AuNPs mediated PTT in tumor treatment remains compromised by several obstacles, including low photothermal conversion efficiency, tissue penetration limitation of excitation light, and inherent non-specificity. In view of the rapid development of AuNPs mediated PTT, we present an in-depth review of major breakthroughs in the advanced development of gold nanomaterials for PTT, with emphasis on those from 2010 to date. In particular, the current state of knowledge for AuNPs based photothermal agents within a paradigm of key structure-optical property relationships is presented in order to provide guidance for the design of novel AuNP based photothermal agents to meet necessary functional requirements in specific applications. Furthermore, potential challenges and future development of AuNP mediated PTT are also elucidated for clinical translation. It is expected that AuNP mediated PTT will soon constitute a markedly promising avenue in the treatment of cancer.
Collapse
|
33
|
Janssen TM, Aitken K, Alongi F, Barry A, Bernchou U, Boeke S, Hall WA, Hosni A, Kroon P, Nachbar M, Saeed H, Jürgenliemk-Schulz IM, Schytte T, Verkooijen HM, Nowee M. First multicentre experience of SABR for lymph node and liver oligometastatic disease on the unity MR-Linac. Tech Innov Patient Support Radiat Oncol 2022; 22:50-54. [PMID: 35586786 PMCID: PMC9108982 DOI: 10.1016/j.tipsro.2022.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 04/21/2022] [Indexed: 10/31/2022] Open
Abstract
Since August 2018 patients are treated on a 1.5 Tesla MR-Linac (MRL) for oligometastatic disease. We present current workflows and practice standards from seven institutions for the initial patients treated for lymph node and liver metastases. In this work a large variation in treatment strategies was found. Since currently there is little evidence preferring one strategy over the other, clinical registries and future research need to focus on the clinical relevance of the variations in institutional treatment strategies.
The treatment of oligometastatic disease using MR guidance is an evolving field. Since August 2018 patients are treated on a 1.5 Tesla MR-Linac (MRL). We present current workflows and practice standards from seven institutions for the initial patients treated for lymph node and liver metastases.
Collapse
|
34
|
Liang E, Dolan JL, Morris ED, Vono J, Bazan LF, Lu M, Glide-Hurst CK. Application of Continuous Positive Airway Pressure for Thoracic Respiratory Motion Management: An Assessment in a Magnetic Resonance Imaging–Guided Radiation Therapy Environment. Adv Radiat Oncol 2022; 7:100889. [PMID: 35198838 PMCID: PMC8844850 DOI: 10.1016/j.adro.2021.100889] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 12/06/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose Patient tolerability of magnetic resonance (MR)–guided radiation treatment delivery is limited by the need for repeated deep inspiratory breath holds (DIBHs). This volunteer study assessed the feasibility of continuous positive airway pressure (CPAP) with and without DIBH for respiratory motion management during radiation treatment with an MR-linear accelerator (MR-linac). Methods and Materials MR imaging safety was first addressed by placing the CPAP device in an MR-safe closet and configuring a tube circuit via waveguide to the magnet bore. Reproducibility and linearity of the final configuration were assessed. Six healthy volunteers underwent thoracic imaging in a 0.35T MR-linac, with one free breathing (FB) and 2 DIBH acquisitions being obtained at 5 pressures from 0 to 15 cm-H2O. Lung and heart volumes and positions were recorded; repeatability was assessed by comparing 2 consecutive DIBH scans. Blinded reviewers graded images for motion artifact using a 3-point grading scale. Participants completed comfort and perception surveys before and after imaging sessions. Results Compared with FB alone, FB-10, FB-12, and FB-15 cm H2O significantly increased lung volumes (+23%, +34%, +44%; all P <.05) and inferiorly displaced the heart (0.86 cm, 0.96 cm, 1.18 cm; all P < . 05). Lung volumes were significantly greater with DIBH-0 cm H2O compared with FB-15 cm H2O (+105% vs +44%, P = .01), and DIBH-15 cm H2O yielded additional volume increase (+131% vs +105%, P = .01). Adding CPAP to DIBH decreased lung volume differences between consecutive breath holds (correlation coefficient 0.97 at 15 cm H2O vs 0.00 at 0 cm H2O). The addition of 15 cm H2O CPAP reduced artifact scores (P = .03) compared with FB; all DIBH images (0-15 cm H2O) had less artifact (P < .01). Conclusions This work demonstrates the feasibility of integrating CPAP in an MR-linac environment in healthy volunteers. Extending this work to a larger patient cohort is warranted to further establish the role of CPAP as an alternative and concurrent approach to DIBH in MR-guided radiation therapy.
Collapse
Affiliation(s)
- Evan Liang
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
- Corresponding author: Evan Liang, MD
| | - Jennifer L. Dolan
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
| | - Eric D. Morris
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
- Department of Radiation Oncology, University of California, Los Angeles, California
| | - Jonathan Vono
- Department of Pulmonary and Sleep Medicine, Henry Ford Health System, Detroit, Michigan
| | - Luisa F. Bazan
- Department of Pulmonary and Sleep Medicine, Henry Ford Health System, Detroit, Michigan
| | - Mei Lu
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
| | - Carri K. Glide-Hurst
- Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan
- Department of Human Oncology, University of Wisconsin, Madison, Wisconsin
| |
Collapse
|
35
|
Lewis BC, Shin J, Maraghechi B, Quinn B, Cole M, Barberi E, Kim JS, Green O, Kim T. Assessment of a novel commercial large field of view phantom for comprehensive MR imaging quality assurance of a 0.35T MRgRT system. J Appl Clin Med Phys 2022; 23:e13535. [PMID: 35194946 PMCID: PMC8992932 DOI: 10.1002/acm2.13535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Revised: 12/25/2021] [Accepted: 12/28/2021] [Indexed: 12/03/2022] Open
Abstract
Consistent quality assurance (QA) programs are vital to MR‐guided radiotherapy (MRgRT), for ensuring treatment is delivered accurately and the onboard MRI system is providing the expected image quality. However, daily imaging QA with a dedicated phantom is not common at many MRgRT centers, especially with large phantoms that cover a field of view (FOV), similar to the human torso. This work presents the first clinical experience with a purpose‐built phantom for large FOV daily and periodic comprehensive quality assurance (QUASAR™ MRgRT Insight Phantom (beta)) from Modus Medical Devices Inc. (Modus QA) on an MRgRT system. A monthly American College of Radiology (ACR) QA phantom was also imaged for reference. Both phantoms were imaged on a 0.35T MR‐Linac, a 1.5T Philips wide bore MRI, and a 3.0T Siemens MRI, with T1‐weighted and T2‐weighted acquisitions. The Insight phantom was imaged in axial and sagittal orientations. Image quality tests including geometric accuracy, spatial resolution accuracy, slice thickness accuracy, slice position accuracy, and image intensity uniformity were performed on each phantom, following their respective instruction manuals. The geometric distortion test showed similar distortions of –1.7 mm and –1.9 mm across a 190 mm and a 283 mm lengths for the ACR and MRgRT Insight phantoms, respectively. The MRgRT Insight phantom utilized a modulation transform function (MTF) for spatial resolution evaluation, which showed decreased performance on the lower B0 strength MRIs, as expected, and could provide a good daily indicator of machine performance. Both the Insight and ACR phantoms showed a match with scan parameters for slice thickness analysis. During the imaging and analysis of this novel MRgRT Insight phantom the authors found setup to be straightforward allowing for easy acquisition each day, and useful image analysis parameters for tracking MRI performance.
Collapse
Affiliation(s)
- Benjamin C Lewis
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
| | - Jaeik Shin
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri.,Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Borna Maraghechi
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
| | | | - Mike Cole
- Modus Medical Devices Inc., London, Ontario, Canada
| | - Enzo Barberi
- Modus Medical Devices Inc., London, Ontario, Canada
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Olga Green
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
| | - Taeho Kim
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri
| |
Collapse
|
36
|
Torshabi A. Investigation the efficacy of fuzzy logic implementation at image-guided radiotherapy. JOURNAL OF MEDICAL SIGNALS & SENSORS 2022; 12:163-170. [PMID: 35755973 PMCID: PMC9215832 DOI: 10.4103/jmss.jmss_76_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2020] [Revised: 04/05/2021] [Accepted: 10/24/2021] [Indexed: 11/04/2022]
|
37
|
Varon E, Blumrosen G, Shefi O. A predictive model for personalization of nanotechnology-based phototherapy in cancer treatment. Front Oncol 2022; 12:1037419. [PMID: 36911792 PMCID: PMC9999042 DOI: 10.3389/fonc.2022.1037419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 11/21/2022] [Indexed: 01/06/2023] Open
Abstract
A major challenge in radiation oncology is the prediction and optimization of clinical responses in a personalized manner. Recently, nanotechnology-based cancer treatments are being combined with photodynamic therapy (PDT) and photothermal therapy (PTT). Predictive models based on machine learning techniques can be used to optimize the clinical setup configuration, including such parameters as laser radiation intensity, treatment duration, and nanoparticle features. In this article we demonstrate a methodology that can be used to identify the optimal treatment parameters for PDT and PTT by collecting data from in vitro cytotoxicity assay of PDT/PTT-induced cell death using a single nanocomplex. We construct three machine learning prediction models, employing regression, interpolation, and low- degree analytical function fitting, to predict the laser radiation intensity and duration settings that maximize the treatment efficiency. To examine the accuracy of these prediction models, we construct a dedicated dataset for PDT, PTT, and a combined treatment; this dataset is based on cell death measurements after light radiation treatment and is divided into training and test sets. The preliminary results show that the performance of all three models is sufficient, with death rate errors of 0.09, 0.15, and 0.12 for the regression, interpolation, and analytical function fitting approaches, respectively. Nevertheless, due to its simple form, the analytical function method has an advantage in clinical application and can be used for further analysis of the sensitivity of performance to the treatment parameters. Overall, the results of this study form a baseline for a future personalized prediction model based on machine learning in the domain of combined nanotechnology- and phototherapy-based cancer treatment.
Collapse
Affiliation(s)
- Eli Varon
- Faculty of Engineering, Bar-Ilan University, Ramat Gan, Israel.,Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel
| | - Gaddi Blumrosen
- Department of Digital Medical Technologies, Holon Institute of Technology, Holon, Israel.,Department of Computer Science, Holon Institute of Technology, Holon, Israel
| | - Orit Shefi
- Faculty of Engineering, Bar-Ilan University, Ramat Gan, Israel.,Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat Gan, Israel.,Gonda Multidisciplinary Brain Research Center, Bar-Ilan University, Ramat Gan, Israel
| |
Collapse
|
38
|
Le Deroff C, Berger L, Bellec J, Boissonnat G, Chesneau H, Chiavassa S, Desrousseaux J, Gempp S, Henry O, Jarril J, Lazaro D, Lefeuvre R, Passal V, Solinhac F, Lafond C, Delpon G. Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy. Phys Imaging Radiat Oncol 2022; 21:108-114. [PMID: 35243041 PMCID: PMC8885460 DOI: 10.1016/j.phro.2022.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 01/28/2022] [Accepted: 02/11/2022] [Indexed: 11/23/2022] Open
Abstract
Monte Carlo calculations offer 3D personalized IGRT imaging dose distributions. Histogram dose volume were obtained for three anatomical sites and 5 imaging device. The image frequency is responsible for the cumulated dose to organs. Adapting the protocols to morphologies reduce the imaging dose.
Background and purpose Image-guided radiotherapy (IGRT) involves frequent in-room imaging sessions contributing to additional patient irradiation. The present work provided patient-specific dosimetric data related to different imaging protocols and anatomical sites. Material and methods We developed a Monte Carlo based software able to calculate 3D personalized dose distributions for five imaging devices delivering kV-CBCT (Elekta and Varian linacs), MV-CT (Tomotherapy machines) and 2D-kV stereoscopic images from BrainLab and Accuray. Our study reported the dose distributions calculated for pelvis, head and neck and breast cases based on dose volume histograms for several organs at risk. Results 2D-kV imaging provided the minimum dose with less than 1 mGy per image pair. For a single kV-CBCT and MV-CT, median dose to organs were respectively around 30 mGy and 15 mGy for the pelvis, around 7 mGy and 10 mGy for the head and neck and around 5 mGy and 15 mGy for the breast. While MV-CT dose varied sparsely with tissues, dose from kV imaging was around 1.7 times higher in bones than in soft tissue. Daily kV-CBCT along 40 sessions of prostate radiotherapy delivered up to 3.5 Gy to the femoral heads. The dose level for head and neck and breast appeared to be lower than 0.4 Gy for every organ in case of a daily imaging session. Conclusions This study showed the dosimetric impact of IGRT procedures. Acquisition parameters should therefore be chosen wisely depending on the clinical purposes and tailored to morphology. Indeed, imaging dose could be reduced up to a factor 10 with optimized protocols.
Collapse
Affiliation(s)
- Coralie Le Deroff
- Centre Eugène Marquis (Unicancer), Rennes, France
- Corresponding author.
| | - Lucie Berger
- Centre Jean Perrin (Unicancer), Clermont Ferrand, France
| | | | | | | | - Sophie Chiavassa
- Institut de Cancérologie de l’Ouest (Unicancer), Saint-Herblain, France
| | | | - Stéphanie Gempp
- Assistance Publique – Hôpitaux de Marseille, Marseille, France
| | | | - Jimmy Jarril
- Centre Jean Perrin (Unicancer), Clermont Ferrand, France
| | - Delphine Lazaro
- Université Paris-Saclay, CEA, List, F-91120 Palaiseau, France
| | | | - Vincent Passal
- Institut de Cancérologie de l’Ouest (Unicancer), Saint-Herblain, France
| | - Fanny Solinhac
- Assistance Publique – Hôpitaux de Marseille, Marseille, France
| | - Caroline Lafond
- Centre Eugène Marquis (Unicancer), Rennes, France
- Université de Rennes, Inserm, LTSI – UMR 1099, Rennes, France
| | - Gregory Delpon
- Institut de Cancérologie de l’Ouest (Unicancer), Saint-Herblain, France
| |
Collapse
|
39
|
de Mol van Otterloo SR, Christodouleas JP, Blezer ELA, Akhiat H, Brown K, Choudhury A, Eggert D, Erickson BA, Daamen LA, Faivre-Finn C, Fuller CD, Goldwein J, Hafeez S, Hall E, Harrington KJ, van der Heide UA, Huddart RA, Intven MPW, Kirby AM, Lalondrelle S, McCann C, Minsky BD, Mook S, Nowee ME, Oelfke U, Orrling K, Philippens MEP, Sahgal A, Schultz CJ, Tersteeg RJHA, Tijssen RHN, Tree AC, van Triest B, Tseng CL, Hall WA, Verkooijen HM. Patterns of Care, Tolerability, and Safety of the First Cohort of Patients Treated on a Novel High-Field MR-Linac Within the MOMENTUM Study: Initial Results From a Prospective Multi-Institutional Registry. Int J Radiat Oncol Biol Phys 2021; 111:867-875. [PMID: 34265394 PMCID: PMC9764331 DOI: 10.1016/j.ijrobp.2021.07.003] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/09/2021] [Accepted: 07/02/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE High-field magnetic resonance-linear accelerators (MR-Linacs), linear accelerators combined with a diagnostic magnetic resonance imaging (MRI) scanner and online adaptive workflow, potentially give rise to novel online anatomic and response adaptive radiation therapy paradigms. The first high-field (1.5T) MR-Linac received regulatory approval in late 2018, and little is known about clinical use, patient tolerability of daily high-field MRI, and toxicity of treatments. Herein we report the initial experience within the MOMENTUM Study (NCT04075305), a prospective international registry of the MR-Linac Consortium. METHODS AND MATERIALS Patients were included between February 2019 and October 2020 at 7 institutions in 4 countries. We used descriptive statistics to describe the patterns of care, tolerability (the percentage of patients discontinuing their course early), and safety (grade 3-5 Common Terminology Criteria for Adverse Events v.5 acute toxicity within 3 months after the end of treatment). RESULTS A total 943 patients participated in the MOMENTUM Study, 702 of whom had complete baseline data at the time of this analysis. Patients were primarily male (79%) with a median age of 68 years (range, 22-93) and were treated for 39 different indications. The most frequent indications were prostate (40%), oligometastatic lymph node (17%), brain (12%), and rectal (10%) cancers. The median number of fractions was 5 (range, 1-35). Six patients discontinued MR-Linac treatments, but none due to an inability to tolerate repeated high-field MRI. Of the 415 patients with complete data on acute toxicity at 3-month follow-up, 18 (4%) patients experienced grade 3 acute toxicity related to radiation. No grade 4 or 5 acute toxicity related to radiation was observed. CONCLUSIONS In the first 21 months of our study, patterns of care were diverse with respect to clinical utilization, body sites, and radiation prescriptions. No patient discontinued treatment due to inability to tolerate daily high-field MRI scans, and the acute radiation toxicity experience was encouraging.
Collapse
Affiliation(s)
| | | | - Erwin L A Blezer
- Division of Imaging, University Medical Center Utrecht, Utrecht, Netherlands
| | | | | | - Ananya Choudhury
- The University of Manchester and The Christie National Health Service Foundation Trust, Manchester, United Kingdom
| | | | - Beth A Erickson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Lois A Daamen
- Division of Imaging, University Medical Center Utrecht, Utrecht, Netherlands
| | - Corinne Faivre-Finn
- The University of Manchester and The Christie National Health Service Foundation Trust, Manchester, United Kingdom
| | - Clifton D Fuller
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center Houston, Houston, Texas
| | | | - Shaista Hafeez
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Emma Hall
- Clinical Trials and Statistics Unit, The Institute of Cancer Research, London, United Kingdom
| | - Kevin J Harrington
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Uulke A van der Heide
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Robert A Huddart
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Martijn P W Intven
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Anna M Kirby
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Susan Lalondrelle
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Claire McCann
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario
| | - Bruce D Minsky
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center Houston, Houston, Texas
| | - Stella Mook
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Marlies E Nowee
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Uwe Oelfke
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | | | | | - Arjun Sahgal
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario
| | - Christopher J Schultz
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Robbert J H A Tersteeg
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Rob H N Tijssen
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - Alison C Tree
- The Royal Marsden NHS Foundation Trust and The Institute of Cancer, London, United Kingdom
| | - Baukelien van Triest
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Chia-Lin Tseng
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre/Odette Cancer Centre, Toronto, Ontario
| | - William A Hall
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Helena M Verkooijen
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands; Division of Imaging, University Medical Center Utrecht, Utrecht, Netherlands.
| |
Collapse
|
40
|
Boscolo D, Kostyleva D, Safari MJ, Anagnostatou V, Äystö J, Bagchi S, Binder T, Dedes G, Dendooven P, Dickel T, Drozd V, Franczack B, Geissel H, Gianoli C, Graeff C, Grahn T, Greiner F, Haettner E, Haghani R, Harakeh MN, Horst F, Hornung C, Hucka JP, Kalantar-Nayestanaki N, Kazantseva E, Kindler B, Knöbel R, Kuzminchuk-Feuerstein N, Lommel B, Mukha I, Nociforo C, Ishikawa S, Lovatti G, Nitta M, Ozoemelam I, Pietri S, Plaß WR, Prochazka A, Purushothaman S, Reidel CA, Roesch H, Schirru F, Schuy C, Sokol O, Steinsberger T, Tanaka YK, Tanihata I, Thirolf P, Tinganelli W, Voss B, Weber U, Weick H, Winfield JS, Winkler M, Zhao J, Scheidenberger C, Parodi K, Durante M. Radioactive Beams for Image-Guided Particle Therapy: The BARB Experiment at GSI. Front Oncol 2021; 11:737050. [PMID: 34504803 PMCID: PMC8422860 DOI: 10.3389/fonc.2021.737050] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Accepted: 08/04/2021] [Indexed: 12/11/2022] Open
Abstract
Several techniques are under development for image-guidance in particle therapy. Positron (β+) emission tomography (PET) is in use since many years, because accelerated ions generate positron-emitting isotopes by nuclear fragmentation in the human body. In heavy ion therapy, a major part of the PET signals is produced by β+-emitters generated via projectile fragmentation. A much higher intensity for the PET signal can be obtained using β+-radioactive beams directly for treatment. This idea has always been hampered by the low intensity of the secondary beams, produced by fragmentation of the primary, stable beams. With the intensity upgrade of the SIS-18 synchrotron and the isotopic separation with the fragment separator FRS in the FAIR-phase-0 in Darmstadt, it is now possible to reach radioactive ion beams with sufficient intensity to treat a tumor in small animals. This was the motivation of the BARB (Biomedical Applications of Radioactive ion Beams) experiment that is ongoing at GSI in Darmstadt. This paper will present the plans and instruments developed by the BARB collaboration for testing the use of radioactive beams in cancer therapy.
Collapse
Affiliation(s)
- Daria Boscolo
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Daria Kostyleva
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | | | | | - Juha Äystö
- University of Jyväskylä, Jyväskylä, Finland.,Helsinki Institute of Physics, Helsinki, Finland
| | | | - Tim Binder
- Ludwig-Maximilians-Universität München, Munich, Germany
| | | | | | - Timo Dickel
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Justus-Liebig-Universität Gießen, Gießen, Germany
| | - Vasyl Drozd
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,University of Groningen, Groningen, Netherlands
| | | | - Hans Geissel
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Justus-Liebig-Universität Gießen, Gießen, Germany
| | | | - Christian Graeff
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Tuomas Grahn
- University of Jyväskylä, Jyväskylä, Finland.,Helsinki Institute of Physics, Helsinki, Finland
| | - Florian Greiner
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Emma Haettner
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | | | | | - Felix Horst
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Christine Hornung
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Technische Universität Darmstadt, Darmstadt, Germany
| | - Jan-Paul Hucka
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Technische Universität Darmstadt, Darmstadt, Germany
| | | | - Erika Kazantseva
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Birgit Kindler
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Ronja Knöbel
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | | | - Bettina Lommel
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Ivan Mukha
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Chiara Nociforo
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | | | | | | | | | - Stephane Pietri
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Wolfgang R Plaß
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Justus-Liebig-Universität Gießen, Gießen, Germany
| | | | | | | | - Heidi Roesch
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Technische Universität Darmstadt, Darmstadt, Germany
| | - Fabio Schirru
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Christoph Schuy
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Olga Sokol
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Timo Steinsberger
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Technische Universität Darmstadt, Darmstadt, Germany
| | | | - Isao Tanihata
- Research Center for Nuclear Physics, Osaka University, Osaka, Japan.,Peking University, Beijing, China.,Institute of Modern Physics, Lanzhou, China
| | - Peter Thirolf
- Ludwig-Maximilians-Universität München, Munich, Germany
| | | | - Bernd Voss
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Uli Weber
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Helmut Weick
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - John S Winfield
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Martin Winkler
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
| | - Jianwei Zhao
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Peking University, Beijing, China
| | - Christoph Scheidenberger
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Justus-Liebig-Universität Gießen, Gießen, Germany
| | - Katia Parodi
- Ludwig-Maximilians-Universität München, Munich, Germany
| | - Marco Durante
- GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany.,Technische Universität Darmstadt, Darmstadt, Germany
| | | |
Collapse
|
41
|
Baumann M, Bacchus C. Radiation Oncology - Towards a mission-oriented approach to cancer. Mol Oncol 2021; 14:1429-1430. [PMID: 32615032 PMCID: PMC7332219 DOI: 10.1002/1878-0261.12730] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Affiliation(s)
| | - Carol Bacchus
- German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
42
|
Liu CH, Grodzinski P. Nanotechnology for Cancer Imaging: Advances, Challenges, and Clinical Opportunities. Radiol Imaging Cancer 2021; 3:e200052. [PMID: 34047667 PMCID: PMC8183257 DOI: 10.1148/rycan.2021200052] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Revised: 02/28/2021] [Accepted: 03/17/2021] [Indexed: 12/11/2022]
Abstract
Nanoparticle (NP) imaging applications have the potential to improve cancer diagnostics, therapeutics, and treatment management. In biomedical research and clinical practice, NPs can serve as labels or labeled carriers for monitoring drug delivery or serve as imaging agents for enhanced imaging contrast, as well as providing improved signal sensitivity and specificity for in vivo imaging of molecular and cellular processes. These qualities offer exciting opportunities for NP-based imaging agents to address current limitations in oncologic imaging. Despite substantial advancements in NP design and development, very few NP-based imaging agents have translated into clinics within the past 5 years. This review highlights some promising NP-enabled imaging techniques and their potential to address current clinical cancer imaging limitations. Although most examples provided herein are from the preclinical space, discussed imaging solutions could offer unique in vivo tools to solve biologic questions, improve cancer treatment effectiveness, and inspire clinical translation innovation to improve patient care. Keywords: Molecular Imaging-Cancer, Molecular Imaging-Nanoparticles, Molecular Imaging-Optical Imaging, Metastases, Oncology, Surgery, Treatment Effects.
Collapse
Affiliation(s)
- Christina H. Liu
- From the Cancer Imaging Program, National Cancer Institute, National
Institutes of Health, 9609 Medical Center Dr, Room 4W216, Rockville, MD
20850
| | - Piotr Grodzinski
- From the Cancer Imaging Program, National Cancer Institute, National
Institutes of Health, 9609 Medical Center Dr, Room 4W216, Rockville, MD
20850
| |
Collapse
|
43
|
Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Comparison to a Standard 3 T MRI. Cancers (Basel) 2021; 13:cancers13071533. [PMID: 33810410 PMCID: PMC8036991 DOI: 10.3390/cancers13071533] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/19/2021] [Accepted: 03/24/2021] [Indexed: 12/11/2022] Open
Abstract
Simple Summary High-precision MR-guided radiotherapy (MRgRT) constitutes the state-of-the-art in the sphere of personalized prostate cancer treatment. To this end, integrating a 1.5 T scanner with a linear accelerator led to the development of MR-Linac (MRL), which could be considered a novel deflection point in radiation oncology. Since the success of both diagnosis and radiation treatment is highly dependent on image quality, geometric integrity, and lesion conspicuity, it is important to investigate the quality of these sequences in comparison to the current diagnostic gold standard multiparametric MRI at 3T (MRI3T), which has not been done before. The purpose of this study is to conduct a qualitative and a quantitative analysis of MRL-images at 1.5 T in patients undergoing MRgRT planning for prostate cancer. Results from this study pave the way for developing safer and more efficient planning workflows in patients with prostate cancer undergoing MR-guided radiotherapy. Abstract The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualitative and quantitative analysis of T2-weighted (T2w) and diffusion-weighted images (DWI). Qualitative outcome measures were as follows: zonal anatomy, capsule demarcation, resolution, visibility of the seminal vesicles, geometric distortion, artifacts, overall image quality, lesion conspicuity, and diagnostic confidence. All ratings were performed on an ordinal 4-point Likert scale. Lesion conspicuity and diagnostic confidence were firstly analyzed only on MRL. Afterwards, these outcome parameters were analyzed in consensus with the MRI3T. Quantitative outcome measures were as follows: anteroposterior and right left diameter of the prostate, lesion size, PI-RADS score (Prostate Imaging—Reporting and Data System) and apparent diffusion coefficient (ADC) of the lesions. Intergroup comparisons were computed using the Wilcoxon-sign rank test and t tests. A post-hoc regression analysis was computed for lesion evaluation. Finally, inter-/intra-reader agreement was analyzed using the Fleiss kappa and intraclass correlation coefficient. For T2w images, the MRL showed good results across all quality criteria (median 3 and 4). Furthermore, there were no significant differences between MRL and MRI3T regarding capsule demarcation or geometric distortion. For the DWI, the MRL performed significantly less than MRI3T across most image quality criteria with a median ranging between 2 and 3. However, there were no significant differences between MRL and MRI3T regarding geometric distortion. In terms of lesion conspicuity and diagnostic confidence, inter-reader agreement was fair for MRL alone (Kappa = 0.42) and good for MRL in consensus with MRI3T (Kappa = 0.708). Thus, lesion conspicuity and diagnostic confidence could be significantly improved when reading MRL images in consensus with MRI3T (Odds ratio: 9- to 11-fold for the T2w images and 5- to 8–fold for the DWI) (p < 0.001). For measures of lesion size, anterior-posterior and right-left prostate diameter, inter-reader and intersequence agreement were excellent (ICC > 0.90) and there were no significant differences between MRL and MRI3T among all three readers. In terms of Prostate Imaging Reporting and Data System (PIRADS) scoring, no significant differences were observed between MRL and MRI3T. Finally, there was a significant positive linear relationship between lesion ADC measurements (r = 0.76, p < 0.01) between the ADC values measured on both systems. In conclusion, image quality for T2w was comparable and diagnostic even without administration of spasmolytic- or contrast agents, while DWI images did not reach diagnostic level and need to be optimized for further exploitation in the setting of MRgRT. Diagnostic confidence and lesion conspicuity were significantly improved by reading MRL in consensus with MRI3T which would be advisable for a safe planning and treatment workflow. Finally, ADC measurements of lesions on both systems were comparable indicating that, lesion ADC as measured on the MRL could be used as a biomarker for evaluation of treatment response, similar to examinations using MRI3T.
Collapse
|
44
|
Boeke S, Mönnich D, van Timmeren JE, Balermpas P. MR-Guided Radiotherapy for Head and Neck Cancer: Current Developments, Perspectives, and Challenges. Front Oncol 2021; 11:616156. [PMID: 33816247 PMCID: PMC8017313 DOI: 10.3389/fonc.2021.616156] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Accepted: 02/01/2021] [Indexed: 02/06/2023] Open
Abstract
Based on the development of new hybrid machines consisting of an MRI and a linear accelerator, magnetic resonance image guided radiotherapy (MRgRT) has revolutionized the field of adaptive treatment in recent years. Although an increasing number of studies have been published, investigating technical and clinical aspects of this technique for various indications, utilizations of MRgRT for adaptive treatment of head and neck cancer (HNC) remains in its infancy. Yet, the possible benefits of this novel technology for HNC patients, allowing for better soft-tissue delineation, intra- and interfractional treatment monitoring and more frequent plan adaptations appear more than obvious. At the same time, new technical, clinical, and logistic challenges emerge. The purpose of this article is to summarize and discuss the rationale, recent developments, and future perspectives of this promising radiotherapy modality for treating HNC.
Collapse
Affiliation(s)
- Simon Boeke
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - David Mönnich
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | | | - Panagiotis Balermpas
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
45
|
Thorwarth D, Low DA. Technical Challenges of Real-Time Adaptive MR-Guided Radiotherapy. Front Oncol 2021; 11:634507. [PMID: 33763369 PMCID: PMC7982516 DOI: 10.3389/fonc.2021.634507] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 01/26/2021] [Indexed: 12/18/2022] Open
Abstract
In the past few years, radiotherapy (RT) has experienced a major technological innovation with the development of hybrid machines combining magnetic resonance (MR) imaging and linear accelerators. This new technology for MR-guided cancer treatment has the potential to revolutionize the field of adaptive RT due to the opportunity to provide high-resolution, real-time MR imaging before and during treatment application. However, from a technical point of view, several challenges remain which need to be tackled to ensure safe and robust real-time adaptive MR-guided RT delivery. In this manuscript, several technical challenges to MR-guided RT are discussed. Starting with magnetic field strength tradeoffs, the potential and limitations for purely MR-based RT workflows are discussed. Furthermore, the current status of real-time 3D MR imaging and its potential for real-time RT are summarized. Finally, the potential of quantitative MR imaging for future biological RT adaptation is highlighted.
Collapse
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany
| | - Daniel A Low
- Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, CA, United States
| |
Collapse
|
46
|
Klaus R, Niyazi M, Lange-Sperandio B. Radiation-induced kidney toxicity: molecular and cellular pathogenesis. Radiat Oncol 2021; 16:43. [PMID: 33632272 PMCID: PMC7905925 DOI: 10.1186/s13014-021-01764-y] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 02/11/2021] [Indexed: 12/19/2022] Open
Abstract
Radiation nephropathy (RN) is a kidney injury induced by ionizing radiation. In a clinical setting, ionizing radiation is used in radiotherapy (RT). The use and the intensity of radiation therapy is limited by normal-tissue damage including kidney toxicity. Different thresholds for kidney toxicity exist for different entities of RT. Histopathologic features of RN include vascular, glomerular and tubulointerstitial damage. The different molecular and cellular pathomechanisms involved in RN are not fully understood. Ionizing radiation causes double-stranded breaks in the DNA, followed by cell death including apoptosis and necrosis of renal endothelial, tubular and glomerular cells. Especially in the latent phase of RN oxidative stress and inflammation have been proposed as putative pathomechanisms, but so far no clear evidence was found. Cellular senescence, activation of the renin–angiotensin–aldosterone-system and vascular dysfunction might contribute to RN, but only limited data is available. Several signalling pathways have been identified in animal models of RN and different approaches to mitigate RN have been investigated. Drugs that attenuate cell death and inflammation or reduce oxidative stress and renal fibrosis were tested. Renin–angiotensin–aldosterone-system blockade, anti-apoptotic drugs, statins, and antioxidants have been shown to reduce the severity of RN. These results provide a rationale for the development of new strategies to prevent or reduce radiation-induced kidney toxicity.
Collapse
Affiliation(s)
- Richard Klaus
- Division of Pediatric Nephrology, Department of Pediatrics, Dr. v. Hauner Children's Hospital, University Hospital, LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,German Cancer Consortium (DKTK), Partner Site Munich, Munich, Germany
| | - Bärbel Lange-Sperandio
- Division of Pediatric Nephrology, Department of Pediatrics, Dr. v. Hauner Children's Hospital, University Hospital, LMU Munich, Lindwurmstr. 4, 80337, Munich, Germany.
| |
Collapse
|
47
|
van Houdt PJ, Yang Y, van der Heide UA. Quantitative Magnetic Resonance Imaging for Biological Image-Guided Adaptive Radiotherapy. Front Oncol 2021; 10:615643. [PMID: 33585242 PMCID: PMC7878523 DOI: 10.3389/fonc.2020.615643] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Accepted: 12/08/2020] [Indexed: 12/20/2022] Open
Abstract
MRI-guided radiotherapy systems have the potential to bring two important concepts in modern radiotherapy together: adaptive radiotherapy and biological targeting. Based on frequent anatomical and functional imaging, monitoring the changes that occur in volume, shape as well as biological characteristics, a treatment plan can be updated regularly to accommodate the observed treatment response. For this purpose, quantitative imaging biomarkers need to be identified that show changes early during treatment and predict treatment outcome. This review provides an overview of the current evidence on quantitative MRI measurements during radiotherapy and their potential as an imaging biomarker on MRI-guided radiotherapy systems.
Collapse
Affiliation(s)
- Petra J van Houdt
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Yingli Yang
- Department of Radiation Oncology, University of California, Los Angeles, CA, United States
| | - Uulke A van der Heide
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, Netherlands
| |
Collapse
|
48
|
Tumor Hypoxia as a Barrier in Cancer Therapy: Why Levels Matter. Cancers (Basel) 2021; 13:cancers13030499. [PMID: 33525508 PMCID: PMC7866096 DOI: 10.3390/cancers13030499] [Citation(s) in RCA: 74] [Impact Index Per Article: 24.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 01/22/2021] [Accepted: 01/23/2021] [Indexed: 02/07/2023] Open
Abstract
Simple Summary Hypoxia is a common feature of solid tumors and associated with poor outcome in most cancer types and treatment modalities, including radiotherapy, chemotherapy, surgery and, most likely, immunotherapy. Emerging strategies, such as proton therapy and combination therapies with radiation and hypoxia targeted drugs, provide new opportunities to overcome the hypoxia barrier and improve therapeutic outcome. Hypoxia is heterogeneously distributed both between and within tumors and shows large variations across patients not only in prevalence, but importantly, also in level. To best exploit the emerging strategies, a better understanding of how individual hypoxia levels from mild to severe affect tumor biology is vital. Here, we discuss our current knowledge on this topic and how we should proceed to gain more insight into the field. Abstract Hypoxia arises in tumor regions with insufficient oxygen supply and is a major barrier in cancer treatment. The distribution of hypoxia levels is highly heterogeneous, ranging from mild, almost non-hypoxic, to severe and anoxic levels. The individual hypoxia levels induce a variety of biological responses that impair the treatment effect. A stronger focus on hypoxia levels rather than the absence or presence of hypoxia in our investigations will help development of improved strategies to treat patients with hypoxic tumors. Current knowledge on how hypoxia levels are sensed by cancer cells and mediate cellular responses that promote treatment resistance is comprehensive. Recently, it has become evident that hypoxia also has an important, more unexplored role in the interaction between cancer cells, stroma and immune cells, influencing the composition and structure of the tumor microenvironment. Establishment of how such processes depend on the hypoxia level requires more advanced tumor models and methodology. In this review, we describe promising model systems and tools for investigations of hypoxia levels in tumors. We further present current knowledge and emerging research on cellular responses to individual levels, and discuss their impact in novel therapeutic approaches to overcome the hypoxia barrier.
Collapse
|
49
|
Bonomo P, Lo Russo M, Nachbar M, Boeke S, Gatidis S, Zips D, Thorwarth D, Gani C. 1.5 T MR-linac planning study to compare two different strategies of rectal boost irradiation. Clin Transl Radiat Oncol 2021; 26:86-91. [PMID: 33336086 PMCID: PMC7732969 DOI: 10.1016/j.ctro.2020.11.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 11/27/2020] [Accepted: 11/29/2020] [Indexed: 02/08/2023] Open
Abstract
PURPOSE To compare treatment plans of two different rectal boost strategies: up-front versus adaptive boost at the 1.5 T MR-Linac. METHODS Patients with locally advanced rectal cancer (LARC) underwent standard neoadjuvant radiochemotherapy with 50.4 Gy in 28 fractions. T2-weighted MRI prior and after the treatment session were acquired to contour gross tumor volumes (GTVs) and organs at risk (OARs). The datasets were used to simulate four different boost strategies (all with 15 Gy/5 fractions in addition to 50.4 Gy): up-front boost (5 daily fractions in the first week of treatment) and an adaptive boost (one boost fraction per week). Both strategies were planned using standard and reduced PTV margins. Intra-fraction motion was assessed by pre- and post-treatment MRI-based contours. RESULTS Five patients were included and a total of 44 MRI sets were evaluated. The median PTV volumes of the adaptive boost were significantly smaller than for the up-front boost (81.4 cm3 vs 44.4 cm3 for PTV with standard margins; 31.2 cm3 vs 15 cm3 for PTV with reduced margins; p = 0.031). With reduced margins the rectum was significantly better spared with an adaptive boost rather than with an up-front boost: V60Gy and V65Gy were 41.2% and 24.8% compared with 59% and 29.9%, respectively (p = 0.031). Median GTV intra-fractional motion was 2 mm (range 0-8 mm). CONCLUSIONS The data suggest that the adaptive boost strategy exploiting tumor-shrinkage and reduced margin might result in better sparing of rectum and anal canal. Individual margin assessment, motion management and real-time adaptive radiotherapy appear attractive applications of the 1.5 T MR-Linac for further testing of individualized and safe dose escalation in patients with rectal cancer.
Collapse
Affiliation(s)
- Pierluigi Bonomo
- Department of Radiation Oncology, Azienda Ospedaliero-Universitaria Careggi, University of Florence, Florence, Italy
| | - Monica Lo Russo
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University, Tübingen, Germany
| | - Marcel Nachbar
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital Tübingen, 72076 Tübingen, Germany
| | - Simon Boeke
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University, Tübingen, Germany
| | - Sergios Gatidis
- Department of Diagnostic and Interventional Radiology, University-Hospital Tübingen, Germany
| | - Daniel Zips
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University, Tübingen, Germany
- German Cancer Research Center (DKFZ) Heidelberg and German Consortium for Translational Cancer Research (DKTK), Partner Site Tübingen, Tübingen, Germany
| | - Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University Hospital Tübingen, 72076 Tübingen, Germany
- German Cancer Research Center (DKFZ) Heidelberg and German Consortium for Translational Cancer Research (DKTK), Partner Site Tübingen, Tübingen, Germany
| | - Cihan Gani
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University, Tübingen, Germany
- German Cancer Research Center (DKFZ) Heidelberg and German Consortium for Translational Cancer Research (DKTK), Partner Site Tübingen, Tübingen, Germany
| |
Collapse
|
50
|
Fabian A, Krug D, Alkatout I. Radiotherapy and Its Intersections with Surgery in the Management of Localized Gynecological Malignancies: A Comprehensive Overview for Clinicians. J Clin Med 2020; 10:E93. [PMID: 33383960 PMCID: PMC7796321 DOI: 10.3390/jcm10010093] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 12/22/2020] [Accepted: 12/24/2020] [Indexed: 02/07/2023] Open
Abstract
Surgery, including minimally invasive surgery, and radiotherapy are key modalities in the treatment of gynecological malignancies. The aim of this review is to offer the multidisciplinary care team a comprehensive summary of the intersections of surgery and radiotherapy in the local treatment of gynecological malignancies. Recent advances in radiotherapy are highlighted. Relevant publications were identified through a review of the published literature. Ovarian, endometrial, cervical, vaginal, and vulvar cancer were included in the search. Current guidelines are summarized. The role of radiotherapy in adjuvant as well as definitive treatment of these entities is synthesized and put into context with surgery, focusing on survival and quality of life. Although these outcomes have improved recently, further research must be focused on the number of life years lost, and the potential morbidity encountered by patients.
Collapse
Affiliation(s)
- Alexander Fabian
- Department of Radiation Oncology, University Hospital of Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany;
| | - David Krug
- Department of Radiation Oncology, University Hospital of Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany;
| | - Ibrahim Alkatout
- Department of Obstetrics and Gynecology, University Hospital of Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105 Kiel, Germany
| |
Collapse
|