1
|
Liang Z, Prentice BM. Quantification of pharmaceutical compounds in tissue and plasma samples using selective ion accumulation with multiple mass isolation windows. JOURNAL OF MASS SPECTROMETRY : JMS 2023; 58:e4958. [PMID: 37431164 PMCID: PMC11193884 DOI: 10.1002/jms.4958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 05/13/2023] [Accepted: 06/09/2023] [Indexed: 07/12/2023]
Abstract
Quantification of pharmaceutical compounds using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is an alternative to traditional liquid chromatography (LC)-MS techniques. Benefits of MALDI-based approaches include rapid analysis times for liquid samples and imaging mass spectrometry capabilities for tissue samples. As in most quantification experiments, the use of internal standards can compensate for spot-to-spot and shot-to-shot variability associated with MALDI sampling. However, the lack of chromatographic separation in traditional MALDI analyses results in diminished peak capacity due to the chemical noise background, which can be detrimental to the dynamic range and limit of detection of these approaches. These issues can be mitigated by using a hybrid mass spectrometer equipped with a quadrupole mass filter (QMF) that can be used to fractionate ions based on their mass-to-charge ratios. When the masses of the analytes and internal standards are sufficiently disparate in mass, it can be beneficial to effect multiple narrow mass isolation windows using the QMF, as opposed to a single wide mass isolation window, to minimize chemical noise while allowing for internal standard normalization. Herein, we demonstrate a MALDI MS quantification workflow incorporating multiple sequential mass isolation windows enabled on a QMF, which divides the total number of MALDI laser shots into multiple segments (i.e., one segment for each mass isolation window). This approach is illustrated through the quantitative analysis of the pharmaceutical compound enalapril in human plasma samples as well as the simultaneous quantification of three pharmaceutical compounds (enalapril, ramipril, and verapamil). Results show a decrease in the limit of detection, relative standard deviations below 10%, and accuracy above 85% for drug quantification using multiple mass isolation windows. This approach has also been applied to the quantification of enalapril in brain tissue from a rat dosed in vitro. The average concentration of enalapril determined by imaging mass spectrometry is in agreement with the concentration determined by LC-MS, giving an accuracy of 104%.
Collapse
Affiliation(s)
- Zhongling Liang
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| | - Boone M. Prentice
- Department of Chemistry, University of Florida, Gainesville, FL 32611
| |
Collapse
|
2
|
Vaysse PM, Heeren RMA, Porta T, Balluff B. Mass spectrometry imaging for clinical research - latest developments, applications, and current limitations. Analyst 2018. [PMID: 28642940 DOI: 10.1039/c7an00565b] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Mass spectrometry is being used in many clinical research areas ranging from toxicology to personalized medicine. Of all the mass spectrometry techniques, mass spectrometry imaging (MSI), in particular, has continuously grown towards clinical acceptance. Significant technological and methodological improvements have contributed to enhance the performance of MSI recently, pushing the limits of throughput, spatial resolution, and sensitivity. This has stimulated the spread of MSI usage across various biomedical research areas such as oncology, neurological disorders, cardiology, and rheumatology, just to name a few. After highlighting the latest major developments and applications touching all aspects of translational research (i.e. from early pre-clinical to clinical research), we will discuss the present challenges in translational research performed with MSI: data management and analysis, molecular coverage and identification capabilities, and finally, reproducibility across multiple research centers, which is the largest remaining obstacle in moving MSI towards clinical routine.
Collapse
Affiliation(s)
- Pierre-Maxence Vaysse
- Maastricht MultiModal Molecular Imaging (M4I) institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| | - Ron M A Heeren
- Maastricht MultiModal Molecular Imaging (M4I) institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| | - Tiffany Porta
- Maastricht MultiModal Molecular Imaging (M4I) institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| | - Benjamin Balluff
- Maastricht MultiModal Molecular Imaging (M4I) institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER, Maastricht, The Netherlands.
| |
Collapse
|
3
|
Qi Y, Müller M, Stokes CS, Volmer DA. Rapid Quantification of 25-Hydroxyvitamin D 3 in Human Serum by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:1456-1462. [PMID: 29633224 DOI: 10.1007/s13361-018-1956-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2018] [Revised: 03/25/2018] [Accepted: 03/26/2018] [Indexed: 06/08/2023]
Abstract
LC-MS/MS is widely utilized today for quantification of vitamin D in biological fluids. Mass spectrometric assays for vitamin D require very careful method optimization for precise and interference-free, accurate analyses however. Here, we explore chemical derivatization and matrix-assisted laser desorption/ionization (MALDI) as a rapid alternative for quantitative measurement of 25-hydroxyvitamin D3 in human serum, and compare it to results from LC-MS/MS. The method implemented an automated imaging step of each MALDI spot, to locate areas of high intensity, avoid sweet spot phenomena, and thus improve precision. There was no statistically significant difference in vitamin D quantification between the MALDI-MS/MS and LC-MS/MS: mean ± standard deviation for MALDI-MS-29.4 ± 10.3 ng/mL-versus LC-MS/MS-30.3 ± 11.2 ng/mL (P = 0.128)-for the sum of the 25-hydroxyvitamin D epimers. The MALDI-based assay avoided time-consuming chromatographic separation steps and was thus much faster than the LC-MS/MS assay. It also consumed less sample, required no organic solvents, and was readily automated. In this proof-of-concept study, MALDI-MS readily demonstrated its potential for mass spectrometric quantification of vitamin D compounds in biological fluids. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Yulin Qi
- Department of Chemistry, Humboldt University of Berlin, Berlin, Germany
| | | | - Caroline S Stokes
- Department of Medicine II, Saarland University Medical Center, Homburg, Germany
| | - Dietrich A Volmer
- Department of Chemistry, Humboldt University of Berlin, Berlin, Germany.
| |
Collapse
|
4
|
Arendowski A, Nizioł J, Ruman T. Silver-109-based laser desorption/ionization mass spectrometry method for detection and quantification of amino acids. JOURNAL OF MASS SPECTROMETRY : JMS 2018; 53:369-378. [PMID: 29415339 DOI: 10.1002/jms.4068] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 12/28/2017] [Accepted: 01/25/2018] [Indexed: 06/08/2023]
Abstract
A new methodology applicable for both high-resolution laser desorption/ionization mass spectrometry and mass spectrometry imaging of amino acids is presented. The matrix-assisted laser desorption ionization-type target containing monoisotopic cationic 109 Ag nanoparticles (109 AgNPs) was used for rapid mass spectrometry measurements of 11 amino acids of different chemical properties. Amino acids were directly tested in 100,000-fold concentration change conditions ranging from 100 μg/mL to 1 ng/mL which equates to 50 ng to 500 fg of amino acid per measurement spot. Limit of detection values obtained suggest that presented method/target system is among the fastest and most sensitive ones in laser mass spectrometry. Mass spectrometry imaging of spots of human blood plasma spiked with amino acids showed their surface distribution allowing optimization of quantitative measurements.
Collapse
Affiliation(s)
- Adrian Arendowski
- Faculty of Chemistry, Rzeszów University of Technology, 6 Powstańców Warszawy Ave, 35-959, Rzeszów, Poland
| | - Joanna Nizioł
- Faculty of Chemistry, Rzeszów University of Technology, 6 Powstańców Warszawy Ave, 35-959, Rzeszów, Poland
| | - Tomasz Ruman
- Faculty of Chemistry, Rzeszów University of Technology, 6 Powstańców Warszawy Ave, 35-959, Rzeszów, Poland
| |
Collapse
|
5
|
Wang P, Giese RW. Recommendations for quantitative analysis of small molecules by matrix-assisted laser desorption ionization mass spectrometry. J Chromatogr A 2017; 1486:35-41. [PMID: 28118972 DOI: 10.1016/j.chroma.2017.01.040] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 12/21/2016] [Accepted: 01/16/2017] [Indexed: 12/15/2022]
Abstract
Matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) has been used for quantitative analysis of small molecules for many years. It is usually preceded by an LC separation step when complex samples are tested. With the development several years ago of "modern MALDI" (automation, high repetition laser, high resolution peaks), the ease of use and performance of MALDI as a quantitative technique greatly increased. This review focuses on practical aspects of modern MALDI for quantitation of small molecules conducted in an ordinary way (no special reagents, devices or techniques for the spotting step of MALDI), and includes our ordinary, preferred methods The review is organized as 18 recommendations with accompanying explanations, criticisms and exceptions.
Collapse
Affiliation(s)
- Poguang Wang
- Department of Pharmaceutical Sciences and Barnett Institute, Bouve College, Northeastern University, Boston, MA 02115, USA
| | - Roger W Giese
- Department of Pharmaceutical Sciences and Barnett Institute, Bouve College, Northeastern University, Boston, MA 02115, USA.
| |
Collapse
|
6
|
Prentice BM, Chumbley CW, Caprioli RM. Absolute Quantification of Rifampicin by MALDI Imaging Mass Spectrometry Using Multiple TOF/TOF Events in a Single Laser Shot. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:136-144. [PMID: 27655354 PMCID: PMC5177505 DOI: 10.1007/s13361-016-1501-2] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 08/31/2016] [Accepted: 09/02/2016] [Indexed: 05/13/2023]
Abstract
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Chad W Chumbley
- Department of Chemistry, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Richard M Caprioli
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA.
- Department of Chemistry, Nashville, TN, 37232, USA.
- Departments of Pharmacology and Medicine, Nashville, TN, 37232, USA.
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA.
| |
Collapse
|
7
|
Rzagalinski I, Volmer DA. Quantification of low molecular weight compounds by MALDI imaging mass spectrometry - A tutorial review. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2016; 1865:726-739. [PMID: 28012871 DOI: 10.1016/j.bbapap.2016.12.011] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Revised: 12/01/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry imaging (MSI) permits label-free in situ analysis of chemical compounds directly from the surface of two-dimensional biological tissue slices. It links qualitative molecular information of compounds to their spatial coordinates and distribution within the investigated tissue. MALDI-MSI can also provide the quantitative amounts of target compounds in the tissue, if proper calibration techniques are performed. Obviously, as the target molecules are embedded within the biological tissue environment and analysis must be performed at their precise locations, there is no possibility for extensive sample clean-up routines or chromatographic separations as usually performed with homogenized biological materials; ion suppression phenomena therefore become a critical side effect of MALDI-MSI. Absolute quantification by MALDI-MSI should provide an accurate value of the concentration/amount of the compound of interest in relatively small, well-defined region of interest of the examined tissue, ideally in a single pixel. This goal is extremely challenging and will not only depend on the technical possibilities and limitations of the MSI instrument hardware, but equally on the chosen calibration/standardization strategy. These strategies are the main focus of this article and are discussed and contrasted in detail in this tutorial review. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann.
Collapse
Affiliation(s)
- Ignacy Rzagalinski
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| | - Dietrich A Volmer
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany.
| |
Collapse
|
8
|
Prentice BM, Chumbley CW, Hachey BC, Norris JL, Caprioli RM. Multiple Time-of-Flight/Time-of-Flight Events in a Single Laser Shot for Improved Matrix-Assisted Laser Desorption/Ionization Tandem Mass Spectrometry Quantification. Anal Chem 2016; 88:9780-9788. [PMID: 27573922 DOI: 10.1021/acs.analchem.6b02821] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Quantitative matrix-assisted laser desorption/ionization time-of-flight (MALDI TOF) approaches have historically suffered from poor accuracy and precision mainly due to the nonuniform distribution of matrix and analyte across the target surface, matrix interferences, and ionization suppression. Tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity as well as improve signal-to-noise ratios by eliminating interferences from chemical noise, alleviating some concerns about dynamic range. However, conventional MALDI TOF/TOF modalities typically only scan for a single MS/MS event per laser shot, and multiplex assays require sequential analyses. We describe here new methodology that allows for multiple TOF/TOF fragmentation events to be performed in a single laser shot. This technology allows the reference of analyte intensity to that of the internal standard in each laser shot, even when the analyte and internal standard are quite disparate in m/z, thereby improving quantification while maintaining chemical specificity and duty cycle. In the quantitative analysis of the drug enalapril in pooled human plasma with ramipril as an internal standard, a greater than 4-fold improvement in relative standard deviation (<10%) was observed as well as improved coefficients of determination (R2) and accuracy (>85% quality controls). Using this approach we have also performed simultaneous quantitative analysis of three drugs (promethazine, enalapril, and verapamil) using deuterated analogues of these drugs as internal standards.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Chad W Chumbley
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Brian C Hachey
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Jeremy L Norris
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| | - Richard M Caprioli
- Department of Biochemistry, ‡Department of Chemistry, §Departments of Pharmacology and Medicine, and ∥Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37232, United States
| |
Collapse
|
9
|
Abstract
Drug analysis represents a large field in different disciplines. Plasma is commonly considered to be the biosample of choice for that purpose. However, concentrations often do not represent the levels present within deeper compartments and therefore cannot sufficiently explain efficacy or toxicology of drugs. MALDI-MS in drug analysis is of great interest for high-throughput quantification and particularly spatially resolved tissue imaging. The current perspective article will deal with challenges and opportunities of MALDI-MS drug analysis in different biological samples. A particular focus will be on hair samples. Recent applications were included, reviewed for their instrumental setup and sample preparation and pros and cons as well as future perspectives are critically discussed.
Collapse
|
10
|
SALDI-TOF-MS analyses of small molecules (citric acid, dexasone, vitamins E and A) using TiO2 nanocrystals as substrates. Anal Bioanal Chem 2016; 408:7481-90. [DOI: 10.1007/s00216-016-9846-8] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 06/28/2016] [Accepted: 07/28/2016] [Indexed: 11/25/2022]
|
11
|
Kiss A, Hopfgartner G. Laser-based methods for the analysis of low molecular weight compounds in biological matrices. Methods 2016; 104:142-53. [DOI: 10.1016/j.ymeth.2016.04.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 02/28/2016] [Accepted: 04/13/2016] [Indexed: 01/26/2023] Open
|
12
|
Arnold A, Persike M, Gorka J, Dommett EJ, Zimmermann M, Karas M. Fast quantitative determination of methylphenidate levels in rat plasma and brain ex vivo by MALDI-MS/MS. JOURNAL OF MASS SPECTROMETRY : JMS 2015; 50:963-971. [PMID: 28338275 DOI: 10.1002/jms.3605] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 04/15/2015] [Accepted: 04/21/2015] [Indexed: 06/06/2023]
Abstract
This study presents a simple and sensitive high-throughput matrix-assisted laser desorption/ionization time-of-flight tandem mass spectrometry (MALDI-MS/MS) method for ex vivo quantification of methylphenidate (MPH) in rat plasma and brain. The common MALDI matrix alpha-cyano-4-hydroxycinnamic acid was used to obtain an optimal dried droplet preparation. For method validation, standards diluted in plasma and brain homogenate prepared from untreated (control) rats were used. MPH was quantified within a concentration range of 0.1-40 ng/ml in plasma and 0.4-40 ng/ml in brain homogenate with an excellent linearity (R2 ≥ 0.9997) and good precision. The intra-day and inter-day accuracies fulfilled the FDA's ±15/20 critera. The recovery of MPH ranged from 93.8 to 98.5% and 87.2 to 99.8% in plasma and homogenate, respectively. We show that MPH is successfully quantified in plasma and brain homogenate of rats pre-treated with this drug using the internal standard calibration method. By means of this method, a linear correlation between plasma and brain concentration of MPH in rodents pre-treated with MPH was detected. The simple sample preparation based on liquid-liquid extraction and MALDI-MS/MS measurement requires approximately 10 s per sample, and this significantly reduces analysis time compared with other analytical methods. To the best of our knowledge, this is the first MALDI-MS/MS method for quantification of MPH in rat plasma and brain. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Anne Arnold
- Cluster of Excellence 'Macromolecular Complexes', Department of Pharmaceutical Chemistry, School of Pharmacy, Goethe University, Frankfurt, Germany
| | - Markus Persike
- Cluster of Excellence 'Macromolecular Complexes', Department of Pharmaceutical Chemistry, School of Pharmacy, Goethe University, Frankfurt, Germany
| | - Jan Gorka
- Cluster of Excellence 'Macromolecular Complexes', Department of Pharmaceutical Chemistry, School of Pharmacy, Goethe University, Frankfurt, Germany
| | - Eleanor J Dommett
- Brain and Behavioural Sciences, Department of Life, Health and Chemical Sciences, Biomedical Research Network, The Open University, Milton Keynes, UK
- Department of Psychology, Institute of Psychiatry, Psychology and Neuroscience, King's College London, London, UK
| | - Martina Zimmermann
- Department of Pharmacology, School of Pharmacy, Goethe University, Frankfurt, Germany
| | - Michael Karas
- Cluster of Excellence 'Macromolecular Complexes', Department of Pharmaceutical Chemistry, School of Pharmacy, Goethe University, Frankfurt, Germany
| |
Collapse
|
13
|
Poetzsch M, Steuer AE, Hysek CM, Liechti ME, Kraemer T. Development of a high-speed MALDI-triple quadrupole mass spectrometric method for the determination of 3,4-methylenedioxymethamphetamine (MDMA) in oral fluid. Drug Test Anal 2015; 8:235-40. [DOI: 10.1002/dta.1810] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 03/27/2015] [Accepted: 04/07/2015] [Indexed: 11/06/2022]
Affiliation(s)
- Michael Poetzsch
- Department of Forensic Pharmacology and Toxicology, ZIFM - Zurich Institute of Forensic Medicine; University of Zurich; Zurich Switzerland
| | - Andrea E. Steuer
- Department of Forensic Pharmacology and Toxicology, ZIFM - Zurich Institute of Forensic Medicine; University of Zurich; Zurich Switzerland
| | - Cedric M. Hysek
- Departement of Biomedicine, Division of Clinical Pharmacology and Toxicology; University Hospital Basel, University of Basel; Basel Switzerland
| | - Matthias E. Liechti
- Departement of Biomedicine, Division of Clinical Pharmacology and Toxicology; University Hospital Basel, University of Basel; Basel Switzerland
| | - Thomas Kraemer
- Department of Forensic Pharmacology and Toxicology, ZIFM - Zurich Institute of Forensic Medicine; University of Zurich; Zurich Switzerland
| |
Collapse
|
14
|
Porta T, Lesur A, Varesio E, Hopfgartner G. Quantification in MALDI-MS imaging: what can we learn from MALDI-selected reaction monitoring and what can we expect for imaging? Anal Bioanal Chem 2014; 407:2177-87. [PMID: 25486918 DOI: 10.1007/s00216-014-8315-5] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 10/29/2014] [Accepted: 11/03/2014] [Indexed: 12/12/2022]
Abstract
Quantification by mass spectrometry imaging (Q-MSI) is one of the hottest topics of the current discussions among the experts of the MS imaging community. If MSI is established as a powerful qualitative tool in drug and biomarker discovery, its reliability for absolute and accurate quantification (QUAN) is still controversial. Indeed, Q-MSI has to deal with several fundamental aspects that are difficult to control, and to account for absolute quantification. The first objective of this manuscript is to review the state-of-the-art of Q-MSI and the current strategies developed for absolute quantification by direct surface sampling from tissue sections. This includes comments on the quest for the perfect matrix-matched standards and signal normalization approaches. Furthermore, this work investigates quantification at a pixel level to determine how many pixels must be considered for accurate quantification by ultraviolet matrix-assisted laser desorption/ionization (MALDI), the most widely used technique for MSI. Particularly, this study focuses on the MALDI-selected reaction monitoring (SRM) in rastering mode, previously demonstrated as a quantitative and robust approach for small analyte and peptide-targeted analyses. The importance of designing experiments of good quality and the use of a labeled compound for signal normalization is emphasized to minimize the signal variability. This is exemplified by measuring the signal for cocaine and a tryptic peptide (i.e., obtained after digestion of a monoclonal antibody) upon different experimental conditions, such as sample stage velocity, laser power and frequency, or distance between two raster lines. Our findings show that accurate quantification cannot be performed on a single pixel but requires averaging of at least 4-5 pixels. The present work demonstrates that MALDI-SRM/MSI is quantitative with precision better than 10-15 %, which meets the requirements of most guidelines (i.e., in bioanalysis or toxicology) for quantification of drugs or peptides from tissue homogenates.
Collapse
Affiliation(s)
- Tiffany Porta
- Life Sciences Mass Spectrometry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Quai Ernest-Ansermet 30, 1211, Geneva 4, Switzerland
| | | | | | | |
Collapse
|
15
|
Recent methodological advances in MALDI mass spectrometry. Anal Bioanal Chem 2014; 406:2261-78. [PMID: 24652146 DOI: 10.1007/s00216-014-7646-6] [Citation(s) in RCA: 78] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2013] [Revised: 01/17/2014] [Accepted: 01/21/2014] [Indexed: 10/25/2022]
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is widely used for characterization of large, thermally labile biomolecules. Advantages of this analytical technique are high sensitivity, robustness, high-throughput capacity, and applicability to a wide range of compound classes. For some years, MALDI-MS has also been increasingly used for mass spectrometric imaging as well as in other areas of clinical research. Recently, several new concepts have been presented that have the potential to further advance the performance characteristics of MALDI. Among these innovations are novel matrices with low proton affinities for particularly efficient protonation of analyte molecules, use of wavelength-tunable lasers to achieve optimum excitation conditions, and use of liquid matrices for improved quantification. Instrumental modifications have also made possible MALDI-MS imaging with cellular resolution as well as an efficient generation of multiply charged MALDI ions by use of heated vacuum interfaces. This article reviews these recent innovations and gives the author's personal outlook of possible future developments.
Collapse
|
16
|
Galesio M, López-Fdez H, Reboiro-Jato M, Gómez-Meire S, Glez-Peña D, Fdez-Riverola F, Lodeiro C, Diniz ME, Capelo JL. Speeding up the screening of steroids in urine: development of a user-friendly library. Steroids 2013; 78:1226-32. [PMID: 24036418 DOI: 10.1016/j.steroids.2013.08.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2013] [Revised: 08/14/2013] [Accepted: 08/23/2013] [Indexed: 12/27/2022]
Abstract
This work presents a novel database search engine - MLibrary - designed to assist the user in the detection and identification of androgenic anabolic steroids (AAS) and its metabolites by matrix assisted laser desorption/ionization (MALDI) and mass spectrometry-based strategies. The detection of the AAS in the samples was accomplished by searching (i) the mass spectrometric (MS) spectra against the library developed to identify possible positives and (ii) by comparison of the tandem mass spectrometric (MS/MS) spectra produced after fragmentation of the possible positives with a complete set of spectra that have previously been assigned to the software. The urinary screening for anabolic agents plays a major role in anti-doping laboratories as they represent the most abused drug class in sports. With the help of the MLibrary software application, the use of MALDI techniques for doping control is simplified and the time for evaluation and interpretation of the results is reduced. To do so, the search engine takes as input several MALDI-TOF-MS and MALDI-TOF-MS/MS spectra. It aids the researcher in an automatic mode by identifying possible positives in a single MS analysis and then confirming their presence in tandem MS analysis by comparing the experimental tandem mass spectrometric data with the database. Furthermore, the search engine can, potentially, be further expanded to other compounds in addition to AASs. The applicability of the MLibrary tool is shown through the analysis of spiked urine samples.
Collapse
Affiliation(s)
- M Galesio
- REQUIMTE, Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica, Portugal
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Nizioł J, Ruman T. Surface-Transfer Mass Spectrometry Imaging on a Monoisotopic Silver Nanoparticle Enhanced Target. Anal Chem 2013; 85:12070-6. [DOI: 10.1021/ac4031658] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Joanna Nizioł
- Rzeszów University of Technology, Faculty of Chemistry, Bioorganic Chemistry Laboratory, 6 Powstańców Warszawy
Ave., 35-959 Rzeszów, Poland
| | - Tomasz Ruman
- Rzeszów University of Technology, Faculty of Chemistry, Bioorganic Chemistry Laboratory, 6 Powstańców Warszawy
Ave., 35-959 Rzeszów, Poland
| |
Collapse
|
18
|
Pabst M, Fagerer SR, Köhling R, Küster SK, Steinhoff R, Badertscher M, Wahl F, Dittrich PS, Jefimovs K, Zenobi R. Self-Aliquoting Microarray Plates for Accurate Quantitative Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry. Anal Chem 2013; 85:9771-6. [DOI: 10.1021/ac4021775] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Martin Pabst
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Stephan R. Fagerer
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Rudolf Köhling
- Sigma-Aldrich, Industriestrasse 25, 9471 Buchs, Switzerland
| | - Simon K. Küster
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Robert Steinhoff
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Martin Badertscher
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Fabian Wahl
- Sigma-Aldrich, Industriestrasse 25, 9471 Buchs, Switzerland
| | - Petra S. Dittrich
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| | - Konstantins Jefimovs
- Swiss Federal Laboratories for Material Science and Technology EMPA, Überlandstrasse 129, 8600 Dübendorf, Switzerland
| | - Renato Zenobi
- Department
of Chemistry and Applied Biosciences, ETH Zürich, Wolfgang-Pauli-Strasse
10, 8093 Zürich, Switzerland
| |
Collapse
|
19
|
Smith AME, Awuah E, Capretta A, Brennan JD. A matrix-assisted laser desorption/ionization tandem mass spectrometry method for direct screening of small molecule mixtures against an aminoglycoside kinase. Anal Chim Acta 2013; 786:103-10. [DOI: 10.1016/j.aca.2013.05.027] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2013] [Revised: 05/10/2013] [Accepted: 05/11/2013] [Indexed: 11/26/2022]
|
20
|
Gode D, Volmer DA. A novel magnet focusing plate for matrix-assisted laser desorption/ionization analysis of magnetic bead-bound analytes. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1011-1018. [PMID: 23592204 DOI: 10.1002/rcm.6548] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2013] [Revised: 02/14/2013] [Accepted: 02/14/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Magnetic beads are often used for serum profiling of peptide and protein biomarkers. In these assays, the bead-bound analytes are eluted from the beads prior to mass spectrometric analysis. This study describes a novel matrix-assisted laser desorption/ionization (MALDI) technique for direct application and focusing of magnetic beads to MALDI plates by means of dedicated micro-magnets as sample spots. METHODS Custom-made MALDI plates with magnetic focusing spots were made using small nickel-coated neodymium micro-magnets integrated into a stainless steel plate in a 16 × 24 (384) pattern. For demonstrating the proof-of-concept, commercial C-18 magnetic beads were used for the extraction of a test compound (reserpine) from aqueous solution. Experiments were conducted to study focusing abilities, the required laser energies, the influence of a matrix compound, dispensing techniques, solvent choice and the amount of magnetic beads. RESULTS Dispensing the magnetic beads onto the micro-magnet sample spots resulted in immediate and strong binding to the magnetic surface. Light microscope images illustrated the homogeneous distribution of beads across the surfaces of the magnets, when the entire sample volume containing the beads was pipetted onto the surface. Subsequent MALDI analysis of the bead-bound analyte demonstrated excellent and reproducible ionization yields. The surface-assisted laser desorption/ionization (SALDI) properties of the strongly light-absorbing γ-Fe2O3-based beads resulted in similar ionization efficiencies to those obtained from experiments with an additional MALDI matrix compound. CONCLUSIONS This feasibility study successfully demonstrated the magnetic focusing abilities for magnetic bead-bound analytes on a novel MALDI plate containing small micro-magnets as sample spots. One of the key advantages of this integrated approach is that no elution steps from magnetic beads were required during analyses compared with conventional bead experiments.
Collapse
Affiliation(s)
- David Gode
- Institute of Bioanalytical Chemistry, Saarland University, Saarbrücken, Germany
| | | |
Collapse
|
21
|
Nizioł J, Rode W, Laskowska B, Ruman T. Novel Monoisotopic 109AgNPET for Laser Desorption/Ionization Mass Spectrometry. Anal Chem 2013; 85:1926-31. [DOI: 10.1021/ac303770y] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Affiliation(s)
- Joanna Nizioł
- Bioorganic Chemistry Laboratory,
Faculty of Chemistry, Rzeszów University of Technology, 6 Powstańców Warszawy Avenue, 35-959 Rzeszów,
Poland
| | - Wojciech Rode
- Nencki Institute of Experimental Biology, 3 Pasteur Street, 02-093 Warsaw,
Poland
| | - Barbara Laskowska
- The State Higher School of Technology and Economics, 16 Czarnieckiego
Street, 37-500 Jarosław, Poland
| | - Tomasz Ruman
- Bioorganic Chemistry Laboratory,
Faculty of Chemistry, Rzeszów University of Technology, 6 Powstańców Warszawy Avenue, 35-959 Rzeszów,
Poland
| |
Collapse
|
22
|
Silina YE, Volmer DA. Nanostructured solid substrates for efficient laser desorption/ionization mass spectrometry (LDI-MS) of low molecular weight compounds. Analyst 2013; 138:7053-65. [DOI: 10.1039/c3an01120h] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
23
|
Pirman DA, Kiss A, Heeren RMA, Yost RA. Identifying tissue-specific signal variation in MALDI mass spectrometric imaging by use of an internal standard. Anal Chem 2012; 85:1090-6. [PMID: 23214468 DOI: 10.1021/ac3029618] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Generating analyte-specific distribution maps of compounds in a tissue sample by matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging (MSI) has become a useful tool in numerous areas across the biological sciences. Direct analysis of the tissue sample provides MS images of an analyte's distribution with minimal sample pretreatment. The technique, however, suffers from the inability to account for tissue-specific variations in ion signal. The variation in the makeup of different tissue types can result in significant differences in analyte extraction, cocrystallization, and ionization across a sample. In this study, a deuterated internal standard was used to account for these signal variations. Initial experiments were performed using pure standards and optimal cutting temperature compound (OCT) to generate known areas of ion suppression. By monitoring the analyte-to-internal-standard ratio, differences in ion signal were taken into account, resulting in images that better represented the analyte concentration. These experiments were then replicated using multiple tissue types in which the analyte's MS signal was monitored. In certain tissues, including liver and kidney, the analyte signal was attenuated by up to 90%; however, when the analyte-to-internal-standard ratio was monitored, these differences were taken into account. These experiments further exemplify the need for an internal standard in the MSI workflow.
Collapse
Affiliation(s)
- David A Pirman
- Department of Chemistry, University of Florida, Gainesville, Florida, 32607, USA
| | | | | | | |
Collapse
|
24
|
Pirman DA, Reich RF, Kiss A, Heeren RMA, Yost RA. Quantitative MALDI tandem mass spectrometric imaging of cocaine from brain tissue with a deuterated internal standard. Anal Chem 2012; 85:1081-9. [PMID: 23214490 DOI: 10.1021/ac302960j] [Citation(s) in RCA: 136] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Mass spectrometric imaging (MSI) is an analytical technique used to determine the distribution of individual analytes within a given sample. A wide array of analytes and samples can be investigated by MSI, including drug distribution in rats, lipid analysis from brain tissue, protein differentiation in tumors, and plant metabolite distributions. Matrix-assisted laser desorption/ionization (MALDI) is a soft ionization technique capable of desorbing and ionizing a large range of compounds, and it is the most common ionization source used in MSI. MALDI mass spectrometry (MS) is generally considered to be a qualitative analytical technique because of significant ion-signal variability. Consequently, MSI is also thought to be a qualitative technique because of the quantitative limitations of MALDI coupled with the homogeneity of tissue sections inherent in an MSI experiment. Thus, conclusions based on MS images are often limited by the inability to correlate ion signal increases with actual concentration increases. Here, we report a quantitative MSI method for the analysis of cocaine (COC) from brain tissue using a deuterated internal standard (COC-d(3)) combined with wide-isolation MS/MS for analysis of the tissue extracts with scan-by-scan COC-to-COC-d(3) normalization. This resulted in significant improvements in signal reproducibility and calibration curve linearity. Quantitative results from the MSI experiments were compared with quantitative results from liquid chromatography (LC)-MS/MS results from brain tissue extracts. Two different quantitative MSI techniques (standard addition and external calibration) produced quantitative results comparable to LC-MS/MS data. Tissue extracts were also analyzed by MALDI wide-isolation MS/MS, and quantitative results were nearly identical to those from LC-MS/MS. These results clearly demonstrate the necessity for an internal standard for quantitative MSI experiments.
Collapse
Affiliation(s)
- David A Pirman
- Department of Chemistry, University of Florida, Gainesville, Florida 32607, USA
| | | | | | | | | |
Collapse
|
25
|
Blaze MMT, Akhmetov A, Aydin B, Edirisinghe PD, Uygur G, Hanley L. Quantification of antibiotic in biofilm-inhibiting multilayers by 7.87 eV laser desorption postionization MS imaging. Anal Chem 2012; 84:9410-5. [PMID: 23017064 PMCID: PMC3491138 DOI: 10.1021/ac302230e] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
The potential of laser desorption postionization mass spectrometry (LDPI-MS) imaging for small molecule quantification is demonstrated here. The N-methylpiperazine acetamide (MPA) of ampicillin was adsorbed into polyelectrolyte multilayer surface coatings composed of chitosan and alginate, both high molecular weight biopolymers. These MPA-ampicillin spiked multilayers were then shown to inhibit the growth of Enterococcus faecalis biofilms that play a role in early stage infection of implanted medical devices. Finally, LDPI-MS imaging using 7.87 eV single-photon ionization was found to detect MPA-ampicillin within the multilayers before and after biofilm growth with limits of quantification and detection of 0.6 and 0.3 nmol, respectively. The capabilities of LDPI-MS imaging for small molecule quantification are compared to those of MALDI-MS. Furthermore, these results indicate that 7.87 eV LDPI-MS imaging should be applicable to quantification of a range of small molecular species on a variety of complex organic and biological surfaces. Finally, while MS imaging for quantification was demonstrated here using LDPI, it is a generally useful strategy that can be applied to other methods.
Collapse
Affiliation(s)
- Melvin M. T. Blaze
- Department of Chemistry, MC 111, University of Illinois at Chicago, Chicago, IL 60607
| | - Artem Akhmetov
- Department of Chemistry, MC 111, University of Illinois at Chicago, Chicago, IL 60607
| | - Berdan Aydin
- Department of Chemistry, MC 111, University of Illinois at Chicago, Chicago, IL 60607
| | | | - Gulsah Uygur
- Department of Chemistry, MC 111, University of Illinois at Chicago, Chicago, IL 60607
| | - Luke Hanley
- Department of Chemistry, MC 111, University of Illinois at Chicago, Chicago, IL 60607
| |
Collapse
|
26
|
Shi T, Su D, Liu T, Tang K, Camp DG, Qian WJ, Smith RD. Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics. Proteomics 2012; 12:1074-92. [PMID: 22577010 PMCID: PMC3375056 DOI: 10.1002/pmic.201100436] [Citation(s) in RCA: 157] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Accepted: 01/12/2012] [Indexed: 12/13/2022]
Abstract
Selected reaction monitoring (SRM) - also known as multiple reaction monitoring (MRM) - has emerged as a promising high-throughput targeted protein quantification technology for candidate biomarker verification and systems biology applications. A major bottleneck for current SRM technology, however, is insufficient sensitivity for, e.g. detecting low-abundance biomarkers likely present at the low ng/mL to pg/mL range in human blood plasma or serum, or extremely low-abundance signaling proteins in cells or tissues. Herein, we review recent advances in methods and technologies, including front-end immunoaffinity depletion, fractionation, selective enrichment of target proteins/peptides including posttranslational modifications, as well as advances in MS instrumentation which have significantly enhanced the overall sensitivity of SRM assays and enabled the detection of low-abundance proteins at low- to sub-ng/mL level in human blood plasma or serum. General perspectives on the potential of achieving sufficient sensitivity for detection of pg/mL level proteins in plasma are also discussed.
Collapse
Affiliation(s)
- Tujin Shi
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - Dian Su
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - Tao Liu
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - Keqi Tang
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - David G. Camp
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - Wei-Jun Qian
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| | - Richard D. Smith
- Biological Sciences Division and Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA 99352
| |
Collapse
|
27
|
Mohamed R, Guy PA. The pivotal role of mass spectrometry in determining the presence of chemical contaminants in food raw materials. MASS SPECTROMETRY REVIEWS 2011; 30:1073-1095. [PMID: 21425183 DOI: 10.1002/mas.20314] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
During recent years, a rising interest from consumers and various governmental organizations towards the quality of food has continuously been observed. Human intervention across the different stages of the food supply chain can lead to the presence of several types of chemical contaminants in food-based products. On a normal daily consumption basis, some of these chemicals are not harmful; however, for those that present a risk to consumers, legislation rules were established to specify tolerance levels or in some cases the total forbiddance of these specific contaminants. Hence, the use of appropriate analytical tools is recommended to properly identify chemical contaminants. In that context, mass spectrometry (MS)-based techniques coupled or not to chromatography offer a vast panel of features such as sensitivity, selectivity, quantification at trace levels, and/or structural elucidation. Because of the complexity of food-based matrices, sample preparation is a crucial step before final detection. In the present manuscript, we review the contribution and the potentialities of MS-based techniques to ensure the absence of chemical contaminants in food-based products.
Collapse
Affiliation(s)
- Rayane Mohamed
- Nestlé Research Center, Nestec Ltd, P.O. Box 44, Vers-Chez-Les-Blanc 1000, Lausanne 26, Switzerland
| | | |
Collapse
|
28
|
Meesters RJW, den Boer E, de Jonge R, Lindemans J, Luider TM. Assessment of intracellular methotrexate and methotrexate-polyglutamate metabolite concentrations in erythrocytes by ultrafast matrix-assisted laser desorption/ionization triple quadrupole tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:3063-3070. [PMID: 21953961 DOI: 10.1002/rcm.5202] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A new ultrafast quantitative and high-throughput mass spectrometric method using matrix-assisted laser desorption/ionization triple quadrupole tandem mass spectrometry has been developed and validated for determination of intracellular erythrocyte concentrations of the antifolate drug methotrexate (MTX) and its polyglutamate metabolites. The method consists of a solid-phase extraction of MTX and MTX-polyglutamate metabolites from deproteinized erythrocyte lysates spiked with aminopterin as internal standard. The newly developed method was validated according to the most recent FDA guidelines on linearity, recovery, within-run and between-run accuracy and precision and stability of the analytes. The low limit of quantification (LLOQ) was 10 nmol/L for all analytes while the limit of detection (LOD) determined at a signal-to-noise (S/N) ratio = 3:1 in drug- free erythrocyte lysate was on average 0.3 nmol/L. After validation, the new method was used in the measurement of intracellular erythrocyte concentrations of MTX and MTX-polyglutamate metabolites (MTXPG2 to MTXPG7) in packed human erythrocyte samples collected from patients with rheumatoid arthritis receiving low-dose oral methotrexate therapy. Mean (SD) intracellular erythrocyte concentrations observed in patient samples were 12.8 (12.6), 12.4 (9.4), 44.4 (30.0), 33.6 (35.9) and 9.4 (8.2) nmol/L for MTX to MTXPG5, respectively, in 10(6) erythrocytes. The highest observed glutamylation degree of MTX was MTXPG5, the very long chain MTX-polyglutamate metabolites MTXPG6 and MTXPG7 were not detected in the packed erythrocyte pellets collected from rheumatoid arthritis patients.
Collapse
Affiliation(s)
- Roland J W Meesters
- Department of Neurology, University Medical Center Rotterdam (ErasmusMC), Rotterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
29
|
Arnold A, Arrey TN, Karas M, Persike M. Fast quantitative determination of melamine and its derivatives by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2011; 25:2844-2850. [PMID: 21913263 DOI: 10.1002/rcm.5170] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A simple, sensitive and fast method for the determination of melamine and its derivatives in milk powder using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed. Neither time-consuming sample preparation, nor special target plates, or other extra equipment are necessary. The common matrix sinapinic acid (SA) was used with a dried-droplet preparation. Detection limits (signal-to-noise (S/N) ratio = 3) for standard solutions of melamine, ammeline and cyanuric acid were 10, 25 and 10 µg/L, respectively. The limit of quantification (LOQ) for melamine was 25 µg/L and excellent linearity (R(2): 0.9990) was maintained over the range of 10-2000 µg/L. Ammeline and cyanuric acid were analyzed with an LOQ of 50 µg/L and also excellent linearity (R(2): 0.9997 and R(2): 0.9998). Good accuracy and precision were obtained for all concentrations within the range of the standard curve. The developed method was successfully used for the determination of melamine, ammeline and cyanuric acid in milk powder samples with a simple sample preparation. The LOQ of melamine was 0.5 µg/g. Ammeline and cyanuric acid were detectable at 0.5 and 5 µg/g. This method showed excellent accuracy, precision and linearity and significantly reduces the needed analysis time, as only approximately 10 s/sample measuring time is required. To the authors' knowledge, this is the first published method to quantify melamine and derivatives by MALDI-TOF-MS.
Collapse
Affiliation(s)
- Anne Arnold
- LOEWE Cluster AmbiProbe, Cluster of Excellence Macromolecular Complexes, Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Germany
| | | | | | | |
Collapse
|
30
|
Ultrafast selective quantification of methotrexate in human plasma by high-throughput MALDI-isotope dilution mass spectrometry. Bioanalysis 2011; 3:1369-78. [PMID: 21679031 DOI: 10.4155/bio.11.113] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND A new analytical MS method using isotope dilution combined with MALDI-triple quadrupole MS/MS has been developed and validated for the determination of methotrexate and 7-hydroxymethotrexate in plasma. Methotrexate, methotrexate-d3, 7-hydroxymethotrexate and 7-hydroxymethotrexate-d3 were monitored by selected reaction monitoring using the transitions m/z 455.2→308.2, 458.2→311.2, 471.2→324.2 and 474.2→327.2 for methotrexate, methotrexate-d3, 7-hydroxymethotrexate and 7-hydroxymethotrexate-d3, respectively. RESULTS The LLOQ was 1 nmol/l for methotrexate and 7-hydroxymethotrexate while the limit of detection was 0.3 nmol/l for both analytes. The new developed method was cross-validated by a fluorescence polarization immunoassay and tested for its clinical feasibility by measuring plasma samples from patients suffering from acute lymphoblastic leukemia. Plasma methotrexate concentrations ranged between 66.0 and 954 nmol/l and observed 7-hydroxymethotrexate/methotrexate ratios ranged between 0.1 and 32.4, respectively. CONCLUSION The new method showed comparable analytical performances as the fluorescence polarization immunoassay, but analyte specificity and sensitivity of the newly developed method were significantly better.
Collapse
|
31
|
Colantonio S, Simpson JT, Fisher RJ, Yavlovich A, Belanger JM, Puri A, Blumenthal R. Quantitative analysis of phospholipids using nanostructured laser desorption ionization targets. Lipids 2011; 46:469-77. [PMID: 21327726 PMCID: PMC3238685 DOI: 10.1007/s11745-010-3493-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2010] [Accepted: 10/20/2010] [Indexed: 10/18/2022]
Abstract
Since its introduction as an ionization technique in mass spectrometry, matrix-assisted laser desorption ionization (MALDI) has been applied to a wide range of applications. Quantitative small molecule analysis by MALDI, however, is limited due to the presence of intense signals from the matrix coupled with non-homogeneous surfaces. The surface used in nano-structured laser desorption ionization (NALDI) eliminates the need for a matrix and the resulting interferences, and allows for quantitative analysis of small molecules. This study was designed to analyze and quantitate phospholipid components of liposomes. Here we have developed an assay to quantitate the DPPC and DC(8,9)PC in liposomes by NALDI following various treatments. To test our method we chose to analyze a liposome system composed of DPPC (1,2-dipalmitoyl-sn-glycero-3-phosphocholine) and DC(8,9)PC (1,2-bis(tricosa-10,12-diynoyl)-sn-glycero-3-phosphocholine), as DC(8,9)PC is known to undergo cross-linking upon treatment with UV (254 nm) and this reaction converts the monomer into a polymer. First, calibration curves for pure lipids (DPPC and DC(8,9)PC) were created using DMPC (1,2-dimyristoyl-sn-glycero-3-phosphocholine) as an internal standard. The calibration curve for both DPPC and DC(8,9)PC showed an R(2) of 0.992, obtained using the intensity ratio of analyte and internal standard. Next, DPPC:DC(8,9)PC liposomes were treated with UV radiation (254 nm). Following this treatment, lipids were extracted from the liposomes and analyzed. The analysis of the lipids before and after UV exposure confirmed a decrease in the signal of DC(8,9)PC of about 90%. In contrast, there was no reduction in DPPC signal.
Collapse
Affiliation(s)
- Simona Colantonio
- Protein Chemistry Laboratory, Advanced Technology Program, SAIC-Frederick/NCI-Frederick, Frederick, MD 21702, USA.
| | | | | | | | | | | | | |
Collapse
|
32
|
Prideaux B, Dartois V, Staab D, Weiner DM, Goh A, Via LE, Barry CE, Stoeckli M. High-sensitivity MALDI-MRM-MS imaging of moxifloxacin distribution in tuberculosis-infected rabbit lungs and granulomatous lesions. Anal Chem 2011; 83:2112-8. [PMID: 21332183 PMCID: PMC3158846 DOI: 10.1021/ac1029049] [Citation(s) in RCA: 204] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
MALDI-MSI is a powerful technology for localizing drug and metabolite distributions in biological tissues. To enhance our understanding of tuberculosis (TB) drug efficacy and how efficiently certain drugs reach their site of action, MALDI-MSI was applied to image the distribution of the second-line TB drug moxifloxacin at a range of time points after dosing. The ability to perform multiple monitoring of selected ion transitions in the same experiment enabled extremely sensitive imaging of moxifloxacin within tuberculosis-infected rabbit lung biopsies in less than 15 min per tissue section. Homogeneous application of a reference standard during the matrix spraying process enabled the ion-suppressing effects of the inhomogeneous lung tissue to be normalized. The drug was observed to accumulate in granulomatous lesions at levels higher than that in the surrounding lung tissue from 1.5 h postdose until the final time point. MALDI-MSI moxifloxacin distribution data were validated by quantitative LC/MS/MS analysis of lung and granuloma extracts from adjacent biopsies taken from the same animals. Drug distribution within the granulomas was observed to be inhomogeneous, and very low levels were observed in the caseum in comparison to the cellular granuloma regions. In this experiment the MALDI-MRM-MSI method was shown to be a rapid and sensitive method for analyzing the distribution of anti-TB compounds and will be applied to distribution studies of additional drugs in the future.
Collapse
Affiliation(s)
- Brendan Prideaux
- Novartis Institutes for BioMedical Research, Basel, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Meesters RJW, van Kampen JJA, Scheuer RD, van der Ende ME, Gruters RA, Luider TM. Determination of the antiretroviral drug tenofovir in plasma from HIV-infected adults by ultrafast isotope dilution MALDI-triple quadrupole tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2011; 46:282-289. [PMID: 21394844 DOI: 10.1002/jms.1897] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A new and reliable mass spectrometric method using an isotope dilution method in combination with matrix-assisted laser desorption/ionization-triple quadrupole tandem mass spectrometry (ID-MALDI-QqQ-MS/MS) has been developed and validated for the determination of concentrations of the antiretroviral drug tenofovir (TNV) in plasma from HIV-infected adults. The advantage of this new method is that (1) the method is ultrafast and (2) can be applied for high-throughput measurement of TNV in plasma. The method is based on a simple plasma deproteinization step in combination with the use of [adenine-(13) C(5) ]-TNV as the internal standard. TNV and [adenine-(13) C(5) ]-TNV were monitored by multiple reaction monitoring using the transition m/z 288.0 → 176.2 and m/z 293.2 → 181.2 for TNV and [adenine-(13) C(5) ]-TNV, respectively. The method was validated according to the most recent FDA guidelines for the development and validation of (new) bio-analytical assays. Validated method parameters were: linearity, accuracy, precision and stability of the method. The lowest limit of quantification was 0.10 µmol/l, whereas the limit of detection determined at a signal-to-noise ratio (S/N = 3:1) in pooled drug free human control plasma was 0.04 µmol/l. The validated method was successfully applied and tested for its clinical feasibility by the analysis of plasma samples from selected HIV-infected adults receiving the prodrug tenofovir disoproxil fumarate. Observed plasma TNV concentrations ranged between 0.11 and 0.76 µmol/l and measured plasma TNV concentrations were within the therapeutically relevant concentration range.
Collapse
Affiliation(s)
- Roland J W Meesters
- Laboratory of Neuro-Oncology and Clinical and Cancer Proteomics, Department of Neurology, University Medical Center Rotterdam, Dr. Molewaterplein 50, 3015 GE Rotterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
34
|
Porta T, Grivet C, Knochenmuss R, Varesio E, Hopfgartner G. Alternative CHCA-based matrices for the analysis of low molecular weight compounds by UV-MALDI-tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2011; 46:144-152. [PMID: 21259393 DOI: 10.1002/jms.1875] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2010] [Accepted: 11/24/2010] [Indexed: 05/30/2023]
Abstract
Analysis of low molecular weight compounds (LMWC) in complex matrices by vacuum matrix-assisted laser desorption/ionization (MALDI) often suffers from matrix interferences, which can severely degrade limits of quantitation. It is, therefore, useful to have available a range of suitable matrices, which exhibit complementary regions of interference. Two newly synthesized α-cyanocinnamic acid derivatives are reported here; (E)-2-cyano-3-(naphthalen-2-yl)acrylic acid (NpCCA) and (2E)-3-(anthracen-9-yl)-2-cyanoprop-2enoic acid (AnCCA). Along with the commonly used α-cyano-4-hydroxycinnamic acid (CHCA), and the recently developed 4-chloro-α-cyanocinnamic acid (Cl-CCA) matrices, these constitute a chemically similar series of matrices covering a range of molecular weights, and with correspondingly differing ranges of spectral interference. Their performance was compared by measuring the signal-to-noise ratios (S/N) of 47 analytes, mostly pharmaceuticals, with the different matrices using the selected reaction monitoring (SRM) mode on a triple quadrupole instrument equipped with a vacuum MALDI source. AnCCA, NpCCA and Cl-CCA were found to offer better signal-to-noise ratios in SRM mode than CHCA, but Cl-CCA yielded the best results for 60% of the compounds tested. To better understand the relative performance of this matrix series, the proton affinities (PAs) were measured using the kinetic method. Their relative values were: AnCCA > CHCA > NpCCA > Cl-CCA. This ordering is consistent with the performance data. The synthesis of the new matrices is straightforward and they provide (1) tunability of matrix background interfering ions and (2) enhanced analyte response for certain classes of compounds.
Collapse
Affiliation(s)
- Tiffany Porta
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Life Sciences Mass Spectrometry, Quai Ernest-Ansermet 30, 1211 Geneva 4, Switzerland
| | | | | | | | | |
Collapse
|
35
|
van Kampen JJA, Burgers PC, de Groot R, Gruters RA, Luider TM. Biomedical application of MALDI mass spectrometry for small-molecule analysis. MASS SPECTROMETRY REVIEWS 2011; 30:101-120. [PMID: 20169623 DOI: 10.1002/mas.20268] [Citation(s) in RCA: 114] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is an emerging analytical tool for the analysis of molecules with molar masses below 1,000 Da; that is, small molecules. This technique offers rapid analysis, high sensitivity, low sample consumption, a relative high tolerance towards salts and buffers, and the possibility to store sample on the target plate. The successful application of the technique is, however, hampered by low molecular weight (LMW) matrix-derived interference signals and by poor reproducibility of signal intensities during quantitative analyses. In this review, we focus on the biomedical application of MALDI-MS for the analysis of small molecules and discuss its favorable properties and its challenges as well as strategies to improve the performance of the technique. Furthermore, practical aspects and applications are presented.
Collapse
Affiliation(s)
- Jeroen J A van Kampen
- Laboratories of Neuro-Oncology/Clinical and Cancer Proteomics, Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|
36
|
Shrivas K, Wu HF. Multifunctional nanoparticles composite for MALDI-MS: Cd2+-doped carbon nanotubes with CdS nanoparticles as the matrix, preconcentrating and accelerating probes of microwave enzymatic digestion of peptides and proteins for direct MALDI-MS analysis. JOURNAL OF MASS SPECTROMETRY : JMS 2010; 45:1452-1460. [PMID: 21053343 DOI: 10.1002/jms.1861] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
For the first time, we utilized multifunctional nanoparticles composite (NPs composite) for matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) analysis of peptides and proteins. Multiwalled carbon nanotubes doped with Cd(2+) ions and modified with cadmium sulfide NPs were synthesized by a chemical reduction method at room temperature. The multifunctional NPs composite applied for the analysis of peptides and microwave-digested proteins in the atmospheric pressure matrix-assisted laser desorption/ionization ion-trap and MALDI time-of-flight (TOF) mass spectrometry (MS) was successfully demonstrated. The maximum detection sensitivity for peptides in MALDI-MS was achieved by the adsorption of negatively charged peptides onto the surfaces of NP composite through electrostatic interactions. The optimal conditions of peptide mixtures were obtained at 20 min of incubation time using 1 mg of NPs composite when the pH of the sample solution was kept higher than the pI values of peptides. The potentiality of the NP composite in the preconcentration of peptides was compared with that of the individual NP by calculating the preconcentration factors (PF) and found that the NPs composite showed a 4-6 times of PF than the other NPs. In addition, the NPs composite was also applied as heat-absorbing materials for efficient microwave tryptic digestion of cytochrome c and lysozyme from milk protein in MALDI-TOF-MS analysis. We believe that the use of NPs composite technique would be an efficient and powerful preconcentrating tool for MALDI-MS for the study of proteome research.
Collapse
Affiliation(s)
- Kamlesh Shrivas
- Department of Chemistry, National Sun Yat-Sen University, 70, Lien-Hai Road, Kaohsiung 80424, Taiwan
| | | |
Collapse
|
37
|
A new ultrafast and high-throughput mass spectrometric approach for the therapeutic drug monitoring of the multi-targeted anti-folate pemetrexed in plasma from lung cancer patients. Anal Bioanal Chem 2010; 398:2943-8. [PMID: 20865407 PMCID: PMC2990004 DOI: 10.1007/s00216-010-4192-8] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Revised: 09/01/2010] [Accepted: 09/02/2010] [Indexed: 11/15/2022]
Abstract
An analytical assay has been developed and validated for ultrafast and high-throughput mass spectrometric determination of pemetrexed concentrations in plasma using matrix assisted laser desorption/ionization–triple quadrupole–tandem mass spectrometry. Patient plasma samples spiked with the internal standard methotrexate were measured by multiple reaction monitoring. The detection limit was 0.4 fmol/μL, lower limit of quantification was 0.9 fmol/μL, and upper limit of quantification was 60 fmol/μL, respectively. Overall observed pemetrexed concentrations in patient samples ranged between 8.7 (1.4) and 142.7 (20.3) pmol/μL (SD). The newly developed mass spectrometric assay is applicable for (routine) therapeutic drug monitoring of pemetrexed concentrations in plasma from non-small cell lung cancer patients.
Collapse
|
38
|
Mass spectrometric imaging of small molecules. Trends Biotechnol 2010; 28:425-34. [DOI: 10.1016/j.tibtech.2010.05.005] [Citation(s) in RCA: 124] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2009] [Revised: 05/12/2010] [Accepted: 05/28/2010] [Indexed: 11/23/2022]
|
39
|
Meesters RJW, van Kampen JJA, Reedijk ML, Scheuer RD, Dekker LJM, Burger DM, Hartwig NG, Osterhaus ADME, Luider TM, Gruters RA. Ultrafast and high-throughput mass spectrometric assay for therapeutic drug monitoring of antiretroviral drugs in pediatric HIV-1 infection applying dried blood spots. Anal Bioanal Chem 2010; 398:319-28. [PMID: 20632164 PMCID: PMC2919689 DOI: 10.1007/s00216-010-3952-9] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2010] [Revised: 06/18/2010] [Accepted: 06/20/2010] [Indexed: 12/01/2022]
Abstract
Kaletra® (Abott Laboratories) is a co-formulated medication used in the treatment of HIV-1-infected children, and it contains the two antiretroviral protease inhibitor drugs lopinavir and ritonavir. We validated two new ultrafast and high-throughput mass spectrometric assays to be used for therapeutic drug monitoring of lopinavir and ritonavir concentrations in whole blood and in plasma from HIV-1-infected children. Whole blood was blotted onto dried blood spot (DBS) collecting cards, and plasma was collected simultaneously. DBS collecting cards were extracted by an acetonitrile/water mixture while plasma samples were deproteinized with acetone. Drug concentrations were determined by matrix-assisted laser desorption/ionization-triple quadrupole tandem mass spectrometry (MALDI-QqQ-MS/MS). The application of DBS made it possible to measure lopinavir and ritonavir in whole blood in therapeutically relevant concentrations. The MALDI-QqQ-MS/MS plasma assay was successfully cross-validated with a commonly used high-performance liquid chromatography (HPLC)–ultraviolet (UV) assay for the therapeutic drug monitoring (TDM) of HIV-1-infected patients, and it showed comparable performance characteristics. Observed DBS concentrations showed as well, a good correlation between plasma concentrations obtained by MALDI-QqQ-MS/MS and those obtained by the HPLC-UV assay. Application of DBS for TDM proved to be a good alternative to the normally used plasma screening. Moreover, collection of DBS requires small amounts of whole blood which can be easily performed especially in (very) young children where collection of large whole blood amounts is often not possible. DBS is perfectly suited for TDM of HIV-1-infected children; but nevertheless, DBS can also easily be applied for TDM of patients in areas with limited or no laboratory facilities.
Collapse
Affiliation(s)
- Roland J W Meesters
- Department of Neurology, Laboratory of Neuro-Oncology and Clinical and Cancer Proteomics, University Medical Center Rotterdam (Erasmus MC), Dr. Molewaterplein 50, Room Ee-1981, 3015 GE Rotterdam, The Netherlands.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
40
|
van Kampen JJA, Reedijk ML, Burgers PC, Dekker LJM, Hartwig NG, van der Ende IE, de Groot R, Osterhaus ADME, Burger DM, Luider TM, Gruters RA. Ultra-fast analysis of plasma and intracellular levels of HIV protease inhibitors in children: a clinical application of MALDI mass spectrometry. PLoS One 2010; 5:e11409. [PMID: 20625386 PMCID: PMC2895665 DOI: 10.1371/journal.pone.0011409] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2009] [Accepted: 05/11/2010] [Indexed: 01/03/2023] Open
Abstract
HIV protease inhibitors must penetrate into cells to exert their action. Differences in the intracellular pharmacokinetics of these drugs may explain why some patients fail on therapy or suffer from drug toxicity. Yet, there is no information available on the intracellular levels of HIV protease inhibitors in HIV infected children, which is in part due to the large amount of sample that is normally required to measure the intracellular concentrations of these drugs. Therefore, we developed an ultra-fast and sensitive assay to measure the intracellular concentrations of HIV protease inhibitors in small amounts of peripheral blood mononuclear cells (PBMCs), and determined the intracellular concentrations of lopinavir and ritonavir in HIV infected children. An assay based on matrix-assisted laser desorption/ionization (MALDI) - triple quadrupole mass spectrometry was developed to determine the concentrations of HIV protease inhibitors in 10 µL plasma and 1×106 PBMCs. Precisions and accuracies were within the values set by the FDA for bioanalytical method validation. Lopinavir and ritonavir did not accumulate in PBMCs of HIV infected children. In addition, the intracellular concentrations of lopinavir and ritonavir correlated poorly to the plasma concentrations of these drugs. MALDI-triple quadrupole mass spectrometry is a new tool for ultra-fast and sensitive determination of drug concentrations which can be used, for example, to assess the intracellular pharmacokinetics of HIV protease inhibitors in HIV infected children.
Collapse
Affiliation(s)
- Jeroen J. A. van Kampen
- Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
- Department of Paediatrics, Erasmus MC – Sophia, Rotterdam, The Netherlands
- Department of Virology, Erasmus MC, Rotterdam, The Netherlands
| | | | | | | | - Nico G. Hartwig
- Department of Paediatrics, Erasmus MC – Sophia, Rotterdam, The Netherlands
| | | | - Ronald de Groot
- Department of Paediatrics, University Medical Centre Nijmegen, Nijmegen, The Netherlands
| | | | - David M. Burger
- Department of Clinical Pharmacy, University Medical Centre Nijmegen, Nijmegen, The Netherlands
| | - Theo M. Luider
- Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
- * E-mail:
| | - Rob A. Gruters
- Department of Virology, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
41
|
Affiliation(s)
- Kamila Chughtai
- FOM-Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| | - Ron M.A. Heeren
- FOM-Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam, The Netherlands
| |
Collapse
|
42
|
Kertesz V, Van Berkel GJ. Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform. JOURNAL OF MASS SPECTROMETRY : JMS 2010; 45:252-60. [PMID: 20020414 DOI: 10.1002/jms.1709] [Citation(s) in RCA: 255] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
A fully automated liquid extraction-based surface sampling device utilizing an Advion NanoMate chip-based infusion nanoelectrospray ionization system is reported. Analyses were enabled for discrete spot sampling by using the Advanced User Interface of the current commercial control software. This software interface provided the parameter control necessary for the NanoMate robotic pipettor to both form and withdraw a liquid microjunction for sampling from a surface. The system was tested with three types of analytically important sample surface types, viz., spotted sample arrays on a MALDI plate, dried blood spots on paper, and whole-body thin tissue sections from drug dosed mice. The qualitative and quantitative data were consistent with previous studies employing other liquid extraction-based surface sampling techniques.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6131, USA.
| | | |
Collapse
|
43
|
Kennedy JH, Wiseman JM. Evaluation and performance of desorption electrospray ionization using a triple quadrupole mass spectrometer for quantitation of pharmaceuticals in plasma. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2010; 24:309-314. [PMID: 20049888 DOI: 10.1002/rcm.4390] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The present work describes the methodology and investigates the performance of desorption electrospray ionization (DESI) combined with a triple quadrupole mass spectrometer for the quantitation of small drug molecules in human plasma. Amoxepine, atenolol, carbamazepine, clozapine, prazosin, propranolol and verapamil were selected as target analytes while terfenadine was selected as the internal standard common to each of the analytes. Protein precipitation of human plasma using acetonitrile was utilized for all samples. Limits of detection were determined for all analytes in plasma and shown to be in the range 0.2-40 ng/mL. Quantitative analysis of amoxepine, prazosin and verapamil was performed over the range 20-7400 ng/mL and shown to be linear in all cases with R(2) >0.99. In most cases, the precision (relative standard deviation) and accuracy (relative error) of each method were less than or equal to 20%, respectively. The performance of the combined techniques made it possible to analyze each sample in 15 s illustrating DESI tandem mass spectrometry (MS/MS) as powerful tool for the quantitation of analytes in deproteinized human plasma.
Collapse
Affiliation(s)
- Joseph H Kennedy
- Prosolia Inc., 351 West 10th Street, Suite 316, Indianapolis, IN 46202, USA
| | | |
Collapse
|
44
|
Persike M, Zimmermann M, Klein J, Karas M. Quantitative Determination of Acetylcholine and Choline in Microdialysis Samples by MALDI-TOF MS. Anal Chem 2010; 82:922-9. [DOI: 10.1021/ac902130h] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Markus Persike
- Cluster of Excellence “Macromolecular Complexes”, Institute of Pharmaceutical Chemistry, and Institute of Pharmacology, Goethe University, Frankfurt, Germany
| | - Martina Zimmermann
- Cluster of Excellence “Macromolecular Complexes”, Institute of Pharmaceutical Chemistry, and Institute of Pharmacology, Goethe University, Frankfurt, Germany
| | - Jochen Klein
- Cluster of Excellence “Macromolecular Complexes”, Institute of Pharmaceutical Chemistry, and Institute of Pharmacology, Goethe University, Frankfurt, Germany
| | - Michael Karas
- Cluster of Excellence “Macromolecular Complexes”, Institute of Pharmaceutical Chemistry, and Institute of Pharmacology, Goethe University, Frankfurt, Germany
| |
Collapse
|
45
|
Koulman A, Petras D, Narayana VK, Wang L, Volmer DA. Comparative high-speed profiling of carboxylic acid metabolite levels by differential isotope-coded MALDI mass spectrometry. Anal Chem 2009; 81:7544-51. [PMID: 19702295 DOI: 10.1021/ac900562j] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
This present work describes the development of a novel high throughput comparative matrix-assisted laser desorption ionization (MALDI) mass spectrometry profiling technique for endogenous compounds using a new isotope-coded label for relative quantitation of carboxylic acids. The key new aspect of this technique was a differential label, 3-hydroxymethyl-1-ethylpyrididinium iodide (HMEP), designed specifically for simultaneous quantitative MALDI analysis of two physiological states. The HMEP-d(0) and HMEP-d(5) variants of the label were applied to profiling endogenous fatty acid levels during a fish oil intervention study, using the metabolite profile of every individual person in the study as their own personal analytical reference standard. Initially, analytical figures of merit such as sensitivity, linear dynamic range, limit of quantitation, and precision were determined from the comparative quantitation experiments. Importantly, the permanently charged HMEP mass tag not only increased the ionization efficiency of the studied fatty acids but also ensured that the solution phase properties of the analytes became more similar, allowing the use of CHCA as a single MALDI matrix compound for the entire range of analytes. The label exhibited a further very unique feature; it provided complete suppression of MALDI matrix-related ions. The MALDI assay was able to generate the data much faster than conventional gas chromatography (GC) methods for fatty acids. It is shown in this study that analyzing a single sample took less than 10 s with analytical results of comparable quality to those obtained by GC.
Collapse
Affiliation(s)
- Albert Koulman
- Medical Research Council, Elsie Widdowson Laboratory, Cambridge, United Kingdom
| | | | | | | | | |
Collapse
|
46
|
Persike M, Karas M. Rapid simultaneous quantitative determination of different small pharmaceutical drugs using a conventional matrix-assisted laser desorption/ionization time-of-flight mass spectrometry system. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:3555-3562. [PMID: 19844965 DOI: 10.1002/rcm.4283] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
The present study establishes a simple, rapid and sensitive method for the simultaneous quantification of different small pharmaceutical drugs using a matrix-assisted laser desorption/ionization source (MALDI) coupled with a time-of-flight (TOF) mass analyzer. Neither time-consuming sample preparation, nor special target plates, isotopically labelled internal standards or other extra equipment are necessary. A simple standard dried-droplet preparation with the common matrix alpha-cyano-4-hydroxycinnamic acid (CHCA) was used. The background signals of CHCA in the low-mass region did not pose the presumed problem, because the sensitivity, resolution and mass accuracy of a modern MALDI-TOF MS system is sufficient to overcome this difficulty. Four experiments were performed in order to verify the quantification method. First, ten different phenothiazines were quantified in the range of 5-2000 nM (1-880 ng/mL). A good precision (relative standard deviation (RSD) 4.4-9.3%), linearity (R2 >0.99) and accuracy (error 4.7-11%) was obtained in all cases. Additionally, simultaneous quantification of these ten phenothiazines was carried out in human plasma without prior chromatographic separation in the range of 2-1750 ng/mL yielding good linearity, precision and accuracy (mean RSD 7.6%; R2 >0.99, mean error 8.0%). Accordingly, a quantitative analysis of ten chemically and pharmaceutically unrelated drugs was performed in the same way. A comparable linearity (R2 >0.99), precision (mean RSD 7.6%) and accuracy (mean error 8.3%) was obtained in the range of 5-2000 nM. Finally, the prazosin content of a commercial tablet was directly determined without further purification steps.
Collapse
Affiliation(s)
- Markus Persike
- Cluster of Excellence Macromolecular Complexes, Institute of Pharmaceutical Chemistry, Goethe University Frankfurt, Max-von-Laue-Str. 9, 60438 Frankfurt, Germany.
| | | |
Collapse
|
47
|
Höfner G, Merkel D, Wanner KT. MS Binding Assays-with MALDI toward High Throughput. ChemMedChem 2009; 4:1523-8. [DOI: 10.1002/cmdc.200900201] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
48
|
Development and validation of a liquid chromatography–atmospheric pressure photoionization–mass spectrometry method for the quantification of alprazolam, flunitrazepam, and their main metabolites in haemolysed blood. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:2275-83. [DOI: 10.1016/j.jchromb.2008.12.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2008] [Revised: 11/28/2008] [Accepted: 12/01/2008] [Indexed: 11/20/2022]
|
49
|
Van Berkel GJ, Kertesz V, King RC. High-Throughput Mode Liquid Microjunction Surface Sampling Probe. Anal Chem 2009; 81:7096-101. [DOI: 10.1021/ac901098d] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Gary J. Van Berkel
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131
| | - Vilmos Kertesz
- Organic and Biological Mass Spectrometry Group, Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6131
| | - Richard C. King
- PharmaCadence, 2880 Bergey Road, Suite AA, Hatfield, Pennsylvania 19440
| |
Collapse
|
50
|
Guénin E, Lecouvey M, Hardouin J. Study of bisphosphonates by matrix-assisted laser desorption/ionization mass spectrometry--influence of alkali atoms on fragmentation patterns. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:1234-1240. [PMID: 19306287 DOI: 10.1002/rcm.3984] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
1-hydroxymethylene-1,1-bisphosphonic acids (or bisphosphonates) are compounds that have interesting pharmacological applications. However, few mass spectrometric investigations have been carried out to determine their fragmentation patterns. Herein, we evaluated different matrices for the study by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of the formation and fragmentation of the protonated, the cationized (MNa+ and MK+) and the deprotonated bisphosphonates. Some in-source fragmentations were observed both in positive and in negative ion modes. The fragmentation patterns obtained in post-source decay mode are also discussed. In contrast to previous electrospray ionization/multi-stage mass spectrometry (ESI-MSn) studies, some new fragmentation pathways were deduced and the effects of alkali ions on the fragmentation patterns were shown. The results summarized here completed the data previously recorded by ESI-MSn and could be used for the characterization of bisphosphonates as alkali complexes in biological mixtures.
Collapse
Affiliation(s)
- Erwann Guénin
- Equipe Chimie Bioorganique et Bionanomatériaux (C2B), Laboratoire de Chimie, Structures, Propriétés de Biomatériaux et d'Agents Thérapeutiques (CSPBAT), Université Paris 13, 74 rue Marcel Cachin, 93017 Bobigny cedex, France
| | | | | |
Collapse
|