1
|
Ueno S, Kawashima D, Matsuura K, Obara H, Tanaka R, Takei M. Real-time prediction of heparin concentration in blood extracorporeal circulation by relaxation time distribution (RTD). Bioelectrochemistry 2025; 163:108912. [PMID: 39862810 DOI: 10.1016/j.bioelechem.2025.108912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 12/04/2024] [Accepted: 01/18/2025] [Indexed: 01/27/2025]
Abstract
Heparin concentration c in a blood extracorporeal circulation has been real-timely predicted based on the relaxation strength Δεm at relaxation frequency fm extracted by relaxation time distribution (RTD). The simulated extracorporeal circulation was conducted to optimize the number of Δεm for the prediction of c using the porcine whole blood (WB) and low-leukocyte and -platelet blood (LLPB) under the condition of the gradual increment of c from 0 to 8 U/mL with constant flow rate and blood temperature. The experimental results show that among the three relaxation strengths Δε1, Δε2 and Δε3 (in ascending order of frequency), Δε2 at f2 = 5.2 ∼ 6.2 MHz and Δε3 at f3 = 42 ∼ 50 MHz were correlated to c. The Δε3 was decreasing with increasing c in both cases, which was influenced by the plasma macromolecular concentrations, while the Δε2 was increased with increasing c in WB case but was hardly changed in LLPB case because the Δε2 is influenced by the blood cell concentrations and the shape changes of blood cell membranes. Heparin concentration c is estimated by the linear regression formula cPRE=a1(Δε2-Δε2c=0)+a2(Δε3-Δε3c=0) (a1 = -0.991, a2 = -0.123) within the mean absolute percentage error (MAPE) of 0.291.
Collapse
Affiliation(s)
- Soichiro Ueno
- Department of Mechanical Engineering, Division of Fundamental Engineering, Graduate School of Science and Engineering, Chiba University, 1-33 Yayoi, Inage, Chiba 263-8522 Japan
| | - Daisuke Kawashima
- Graduate School of Engineering, Chiba University, 1-33 Yayoi, Inage, Chiba 263-8522 Japan.
| | - Katsuhiro Matsuura
- Veterinary teaching hospital, Tokyo University of Agriculture and Technology, 3-5-8, Saiwaicho, Fuchu, Tokyo 183-0054 Japan; Department of Small Animal Clinical Sciences, College of Veterinary Medicine University of Florida, 2015 SW 16th Ave, Gainesville, FL 32608, United States
| | - Hiromichi Obara
- Department of Mechanical System Engineering, Tokyo Metropolitan University, 6-6 Asahigaoka, Hino-shi, Tokyo 191-0065, Japan
| | - Ryou Tanaka
- Veterinary teaching hospital, Tokyo University of Agriculture and Technology, 3-5-8, Saiwaicho, Fuchu, Tokyo 183-0054 Japan
| | - Masahiro Takei
- Graduate School of Engineering, Chiba University, 1-33 Yayoi, Inage, Chiba 263-8522 Japan
| |
Collapse
|
2
|
Luo J, Lu W, Jang D, Zhang Q, Meng W, Wells A, Alavi AH. Millifluidic Nanogenerator Lab-on-a-Chip Device for Blood Electrical Conductivity Monitoring at Low Frequency. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2403568. [PMID: 38814691 DOI: 10.1002/adma.202403568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2024] [Revised: 04/27/2024] [Indexed: 05/31/2024]
Abstract
The electrical conductivity of blood is a crucial physiological parameter with diverse applications in medical diagnostics. Here, a novel approach utilizing a portable millifluidic nanogenerator lab-on-a-chip device for measuring blood conductivity at low frequencies, is introduced. The proposed device employs blood as a conductive substance within its built-in triboelectric nanogenerator system. The voltage generated by this blood-based nanogenerator device is analyzed to determine the electrical conductivity of the blood sample. The self-powering functionality of the device eliminates the need for complex embedded electronics and external electrodes. Experimental results using simulated body fluid and human blood plasma demonstrate the device's efficacy in detecting variations in conductivity related to changes in electrolyte concentrations. Furthermore, artificial intelligence models are used to analyze the generated voltage patterns and to estimate the blood electrical conductivity. The models exhibit high accuracy in predicting conductivity based solely on the device-generated voltage. The 3D-printed, disposable design of the device enhances portability and usability, providing a point-of-care solution for rapid blood conductivity assessment. A comparative analysis with traditional conductivity measurement methods highlights the advantages of the proposed device in terms of simplicity, portability, and adaptability for various applications beyond blood analysis.
Collapse
Affiliation(s)
- Jianzhe Luo
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Wenyun Lu
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Daeik Jang
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Qianyun Zhang
- Department of Civil Engineering, New Mexico State University, Las Cruces, NM, 88003, USA
| | - Wenxuan Meng
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| | - Alan Wells
- Laboratory Service Center, University of Pittsburgh Medical Center, Pittsburgh, PA, 15213, USA
- Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, PA, 15213, USA
| | - Amir H Alavi
- Department of Civil and Environmental Engineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, 15261, USA
- Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA, 15261, USA
| |
Collapse
|
3
|
Kamel AA, Alawajji RA, Kannarpady GK. The cavity perturbation method for evaluating hematocrit via dielectric properties. Biomed Phys Eng Express 2023; 9:065029. [PMID: 37883952 DOI: 10.1088/2057-1976/ad0740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 10/26/2023] [Indexed: 10/28/2023]
Abstract
The physical parameters of human blood (complex permittivity and conductivity) at microwave frequencies have been investigated to assess the hematocrit (HCT). The cavity perturbation method based on a rectangular cavity operated in TE101mode at frequency 4.212 GHz has been utilized to measure the permittivity of blood with different hematocrit % at a range of temperatures. According to the results, the dielectric constant, loss factor, and conductivity appeared to be influenced by HCT level. Though the dielectric constant is the only parameter that shows clear linear regression decreasing behavior with a correlation value around (R2= 0.93). For thirty healthy donors the dielectric constant decreases from (65.61 ± 1.4 to 44.64 ± 4.0) and from (65.3 ± 1.2 to 48.3 ± 1.88) for men and women, respectively, with increasing hematocrit percentage from 20% HCT up to 95% HCT. The temperature dependence of the dielectric constant is also examined in the temperature range 27 °C-50 °C and the results display a slight decrease in dielectric constant with elevation temperature. The temperature-dependence dielectric constant of water and blood samples were fitted to an empirical polynomial with temperature. A comparison of estimated HCT using the cavity technique based on dielectric properties shows a very good agreement with commercially standard HCT measurement methods. Finally, the cavity technique can be applied to measure the hematocrit up to high values based on the dielectric constant with high precision, simplicity, and low cost compared with traditional techniques.
Collapse
Affiliation(s)
- Abdulla A Kamel
- Department of Physics, College of Science, University of Basrah, Basrah, 61004, Iraq
| | - Raad A Alawajji
- Department of Physics, College of Science, University of Basrah, Basrah, 61004, Iraq
| | - Ganesh K Kannarpady
- Center for Integrative Nanotechnology Sciences, University of Arkansas at Little Rock, 2801 South University Avenue, Little Rock, AR 72204, United States of America
| |
Collapse
|
4
|
Sherif S, Ghallab YH, AbdelRaheem O, Ziko L, Siam R, Ismail Y. Optimization design of interdigitated microelectrodes with an insulation layer on the connection tracks to enhance efficiency of assessment of the cell viability. BMC Biomed Eng 2023; 5:4. [PMID: 37127658 PMCID: PMC10150490 DOI: 10.1186/s42490-023-00070-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 03/16/2023] [Indexed: 05/03/2023] Open
Abstract
BACKGROUND Microelectrical Impedance Spectroscopy (µEIS) is a tiny device that utilizes fluid as a working medium in combination with biological cells to extract various electrical parameters. Dielectric parameters of biological cells are essential parameters that can be extracted using µEIS. µEIS has many advantages, such as portability, disposable sensors, and high-precision results. RESULTS The paper compares different configurations of interdigitated microelectrodes with and without a passivation layer on the cell contact tracks. The influence of the number of electrodes on the enhancement of the extracted impedance for different types of cells was provided and discussed. Different types of cells are experimentally tested, such as viable and non-viable MCF7, along with different buffer solutions. This study confirms the importance of µEIS for in vivo and in vitro applications. An essential application of µEIS is to differentiate between the cells' sizes based on the measured capacitance, which is indirectly related to the cells' size. The extracted statistical values reveal the capability and sensitivity of the system to distinguish between two clusters of cells based on viability and size. CONCLUSION A completely portable and easy-to-use system, including different sensor configurations, was designed, fabricated, and experimentally tested. The system was used to extract the dielectric parameters of the Microbeads and MCF7 cells immersed in different buffer solutions. The high sensitivity of the readout circuit, which enables it to extract the difference between the viable and non-viable cells, was provided and discussed. The proposed system can extract and differentiate between different types of cells based on cells' sizes; two other polystyrene microbeads with different sizes are tested. Contamination that may happen was avoided using a Microfluidic chamber. The study shows a good match between the experiment and simulation results. The study also shows the optimum number of interdigitated electrodes that can be used to extract the variation in the dielectric parameters of the cells without leakage current or parasitic capacitance.
Collapse
Affiliation(s)
- Sameh Sherif
- Biomedical Engineering Department, Helwan University, Cairo, Egypt.
- Center of Nanoelectronics and Devices (CND), Zewail City of Science and Technology and The American University in Cairo (AUC), Cairo, Egypt.
| | - Yehya H Ghallab
- Biomedical Engineering Department, Helwan University, Cairo, Egypt
- Center of Nanoelectronics and Devices (CND), Zewail City of Science and Technology and The American University in Cairo (AUC), Cairo, Egypt
| | - Omnia AbdelRaheem
- Department of Biology, School of Sciences and Engineering, The American University in Cairo(AUC), Cairo, Egypt
| | - Laila Ziko
- Department of Biology, School of Sciences and Engineering, The American University in Cairo(AUC), Cairo, Egypt
- School of Life and Medical Sciences, the University of Hertfordshire, Hosted By Global Academic Foundation, Cairo, Egypt
| | - Rania Siam
- Department of Biology, School of Sciences and Engineering, The American University in Cairo(AUC), Cairo, Egypt
| | - Yehea Ismail
- Center of Nanoelectronics and Devices (CND), Zewail City of Science and Technology and The American University in Cairo (AUC), Cairo, Egypt
| |
Collapse
|
5
|
Wang W, Li W, Liu B, Wang L, Li K, Wang Y, Ji Z, Xu C, Shi X. Temperature dependence of dielectric properties of blood at 10 Hz-100 MHz. Front Physiol 2022; 13:1053233. [PMID: 36388092 PMCID: PMC9644111 DOI: 10.3389/fphys.2022.1053233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 10/14/2022] [Indexed: 11/07/2023] Open
Abstract
The temperature dependence of the dielectric properties of blood is important for studying the biological effects of electromagnetic fields, electromagnetic protection, disease diagnosis, and treatment. However, owing to the limitations of measurement methods, there are still some uncertainties regarding the temperature characteristics of the dielectric properties of blood at low and medium frequencies. In this study, we designed a composite impedance measurement box with high heat transfer efficiency that allowed for a four/two-electrode measurement method. Four-electrode measurements were carried out at 10 Hz-1 MHz to overcome the influence of electrode polarization, and two-electrode measurements were carried out at 100 Hz-100 MHz to avoid the influence of distribution parameters, and the data was integrated to achieve dielectric measurements at 10 Hz-100 MHz. At the same time, the temperature of fresh blood from rabbits was controlled at 17-39°C in combination with a temperature-controlled water sink. The results showed that the temperature coefficient for the real part of the resistivity of blood remained constant from 10 Hz to 100 kHz (-2.42%/°C) and then gradually decreased to -0.26%/°C. The temperature coefficient of the imaginary part was positive and bimodal from 6.31 kHz to 100 MHz, with peaks of 5.22%/°C and 4.14%/°C at 126 kHz and 39.8 MHz, respectively. Finally, a third-order function model was developed to describe the dielectric spectra at these temperatures, in which the resistivity parameter in each dispersion zone decreased linearly with temperature and each characteristic frequency increased linearly with temperature. The model could estimate the dielectric properties at any frequency and temperature in this range, and the maximum error was less than 1.39%, thus laying the foundation for subsequent studies.
Collapse
Affiliation(s)
- Weice Wang
- Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Weichen Li
- School of Life Sciences, Northwest University, Xi’an, China
| | - Benyuan Liu
- Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Lei Wang
- Institute of Medical Research, Northwestern Polytechnical University, Xi’an, China
| | - Kun Li
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
| | - Yu Wang
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
| | - Zhenyu Ji
- Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Canhua Xu
- Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Xuetao Shi
- Shaanxi Provincial Key Laboratory of Bioelectromagnetic Detection and Intelligent Perception, Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| |
Collapse
|
6
|
Slanina T, Nguyen DH, Moll J, Krozer V. Temperature dependence studies of tissue-mimicking phantoms for ultra-wideband microwave breast tumor detection. Biomed Phys Eng Express 2022; 8. [PMID: 35835081 DOI: 10.1088/2057-1976/ac811b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 07/14/2022] [Indexed: 11/12/2022]
Abstract
Microwave imaging (MWI) systems are being investigated for breast cancer diagnostics as an alternative to conventional X-ray mammography and breast ultrasound. This work aims at a next generation of tissue-mimicking phantoms modelling the temperature-dependent dielectric properties of breast tissue over a large frequency bandwidth. Such phantoms can be used to develop a novel kind of MWI systems that exploit the temperature-dependent permittivity of tissue as a natural contrast agent. Due to the higher water content in tumor tissue, a temperature increase leads to a different change in the complex permittivity compared to surrounding tissue. This will generate a tumor dominated scattering response when the overall tissue temperature increases by a few degrees, e.g. through the use of microwave hyperthermia systems. In that case a differential diagnostic image can be calculated between microwave measurements at reference (around 37◦C) and elevated temperature conditions. This work proposes the design and characterization of agar-oil-glycerin phantoms for fatty, glandular, skin and tumor tissue. The characterization includes measurements with an open-ended coaxial probe and a network analyzer for the frequency range from 50 MHz to 20 GHz in a temperature-controlled environment covering the temperature range from 25◦C to 46◦C. The phantoms show an unique temperature response over the considered frequency bandwidth leading to significant changes in the real and imaginary part of the complex permittivity. Comparative studies with porcine skin and fat tissue show a qualitative agreement.
Collapse
Affiliation(s)
- Teresa Slanina
- Goethe University Frankfurt am Main Physical Institute, Max-von-Laue Straße 1, 60438 Frankfurt am Main, Frankfurt am Main, 60438, GERMANY
| | - Duy Hai Nguyen
- Goethe-Universitat Frankfurt am Main Physikalisches Institut, Max-von-Laue Straße 1, 60438 Frankfurt am Main, Goethe Universität, Frankfurt am Main, Hessen, 60438, GERMANY
| | - Jochen Moll
- Physics, Goethe University Frankfurt, Max von Laue Str. 1, 60438 Frankfurt, Frankfurt am Main, 60438 , GERMANY
| | - Viktor Krozer
- Physikalisches Institut, Johann-Wolfgang-Goethe-Universitat, Max-von-Laue Straße 1, 60438 Frankfurt am Main, Frankfurt am Main, 60438, GERMANY
| |
Collapse
|
7
|
Pasternak G, Pentoś K, Łuczycka D, Kaźmierowska-Niemczuk M, Lewandowicz-Uszyńska A. Serum Impedance in Children with Recurrent Respiratory Infections. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1375:47-54. [DOI: 10.1007/5584_2021_689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
8
|
Su L, Xu SZ, Huang YX, Wu Q, Hou ZW. Developing a near-infrared spectroscopy and microwave-induced thermoacoustic tomography-based dual-modality imaging system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:124901. [PMID: 34972469 DOI: 10.1063/5.0067878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 12/01/2021] [Indexed: 06/14/2023]
Abstract
Near-infrared spectroscopy (NIRS) techniques can provide noninvasive in vivo hemoglobin oxygenation information but suffer from relatively low resolution in biological tissue imaging. Microwave-induced thermoacoustic tomography (TAT) can produce high-resolution images of the biological tissue anatomy but offer limited physiological information of samples because of the single species of the chromophore it maps. To overcome these drawbacks and take advantage of the merits of the two independent techniques, we built a dual-modality system by combining a NIRS system and a TAT system to image biological tissues. A series of phantom trials were carried out to demonstrate the performance of the new system. The spatial resolution is about 1 mm, with a penetration depth of at least 17.5 mm in the human subject. A cohort of five healthy subjects was recruited to conduct real-time forearm venous and arterial cuff occlusion experiments. Numerous results showed that this dual-modality system could measure oxygen metabolism and simultaneously provide anatomical structure changes of biological tissues. We also found that although the hemoglobin concentration varied consistently with many other published papers, the TAT signal intensity of veins showed an opposite variation tendency in the venous occlusion stage compared with other existing work. A detailed explanation is given to account for the discrepancy, thus, providing another possibility for the forearm experiments using TAT. Furthermore, based on the multiple types of information afforded by this dual-modality system, a pilot clinical application for the diagnosis of anemia is discussed.
Collapse
Affiliation(s)
- L Su
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, 611731 Chengdu, China
| | - S Z Xu
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, 611731 Chengdu, China
| | - Y X Huang
- School of Physics, University of Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, 611731 Chengdu, China
| | - Q Wu
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, 611731 Chengdu, China
| | - Z W Hou
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China, No. 2006, Xiyuan Avenue, 611731 Chengdu, China
| |
Collapse
|
9
|
Islam S, Gulati RK, Domic M, Pal A, Kant K, Kim A. Performance Evaluation of Magnetic Resonance Coupling Method for Intra-Body Network (IBNet). IEEE Trans Biomed Eng 2021; 69:1901-1908. [PMID: 34818185 DOI: 10.1109/tbme.2021.3130408] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Effective management of emerging medical devices can lead to new insights in healthcare. Thus, a human body communication (HBC) is becoming increasingly important. In this paper, we present magnetic resonance (MR) coupling as a promising method for intra-body network (IBNet). The study reveals that MR coupling can effectively send or receive signals in biological tissue, with a maximum path loss of PL 33 dB (i.e. at 13.56 MHz), which is lower than other methods (e.g., galvanic, capacitive, or RF) for the same distance. The angular orientation of the transmitter and receiver coils at short and long distances also show a minor variation of the path loss (0.19 PL 0.62 dB), but more dependency on the distance (0.0547 dB/cm). Additionally, different postures during the MR coupling essentially do not affect path loss (PL 0.21 dB). In the multi-nodal transmission scenario, the MR coupling demonstrates that two nodes can simultaneously receive signals with -16.77 dBm loss at 60 cm and 100 cm distances, respectively. Such multi-node MR transmission can be utilized for communication, sensing, and powering wearable and implantable devices.
Collapse
|
10
|
Berger M, Zygmanowski A, Zimmermann S. Differential Inductive Sensing System for Truly Contactless Measuring of Liquids' Electromagnetic Properties in Tubing. SENSORS (BASEL, SWITZERLAND) 2021; 21:5535. [PMID: 34450977 PMCID: PMC8402242 DOI: 10.3390/s21165535] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 08/13/2021] [Accepted: 08/16/2021] [Indexed: 11/28/2022]
Abstract
Certain applications require a contactless measurement to eliminate the risk of sensor-induced sample contamination. Examples can be found in chemical process control, biotechnology or medical technology. For instance, in critically ill patients requiring renal replacement therapy, continuous in-line monitoring of blood conductivity as a measure for sodium should be considered. A differential inductive sensing system based on a differential transformer using a specific flow chamber has already proven suitable for this application. However, since the blood in renal replacement therapy is carried in plastic tubing, a direct measurement through the tubing offers a contactless method. Therefore, in this work we present a differential transformer for measuring directly through electrically non-conductive tubing by winding the tube around the ferrite core of the transformer. Here, the dependence of the winding type and the number of turns of the tubing on the sensitivity has been analyzed by using a mathematical model, simulations and experimental validation. A maximum sensitivity of 364.9 mV/mol/L is measured for radial winding around the core. A longitudinal winding turns out to be less effective with 92.8 mV/mol/L. However, the findings prove the ability to use the differential transformer as a truly contactless sensing system.
Collapse
Affiliation(s)
- Marc Berger
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, 30167 Hannover, Germany; (A.Z.); (S.Z.)
| | | | | |
Collapse
|
11
|
Sodhi CS, Ozelim LCDSM, Rathie PN. Dielectric relaxation model of human blood as a superposition of Debye functions with relaxation times following a Modified-Weibull distribution. Heliyon 2021; 7:e06606. [PMID: 33851060 PMCID: PMC8022844 DOI: 10.1016/j.heliyon.2021.e06606] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Revised: 02/02/2021] [Accepted: 03/23/2021] [Indexed: 11/27/2022] Open
Abstract
Dielectric spectroscopy of the human blood is a powerful and convenient non-invasive testing technique that can be used to diagnose diseases such as diabetes and leukemia. One needs to consider rigorous experimental procedures and mathematical models to make the results of this type of test comparable. The present paper will discuss previously published results to further investigate the statistical modeling of the dielectric properties of human blood. The analysis shows that previously published results were related to Modified Weibull (MW) distributions of relaxation times, not Gaussian distributions, as reported. This re-analysis prevents the ill definition of fitting parameters, making sure they present physically justifiable values. Besides, for fluids presenting a Modified Weibull distribution of relaxation times, novel exact and closed-form expressions for the real and imaginary parts of complex permittivities were obtained in terms of generalized hypergeometric functions. Also, a high accuracy approximation was built for the imaginary part of the complex permittivity, creating an easy-to-use alternative expression for practitioners. The new results are used to fit experimental results for human blood, showing that more robust estimators are built for the parameters involved, which can be used as thresholds to classify the dielectric behavior of blood as normal (healthy) or anomalous (sick).
Collapse
|
12
|
Urban S, Lalik S, Różycka A, Iwan A, Marzec M. Dielectric studies in the isotropic phase of six symmetrical azomethines with various number of benzene rings. Influence of the ionic conductivity. J Mol Liq 2021. [DOI: 10.1016/j.molliq.2021.115477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
13
|
Liu J, Qiang Y, Du E. Dielectric spectroscopy of red blood cells in sickle cell disease. Electrophoresis 2021; 42:667-675. [PMID: 33314275 DOI: 10.1002/elps.202000143] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 12/03/2020] [Accepted: 12/07/2020] [Indexed: 01/18/2023]
Abstract
Hypoxia-induced polymerization of sickle hemoglobin and the related ion diffusion across cell membrane can lead to changes in cell dielectric properties, which can potentially serve as label-free, diagnostic biomarkers for sickle cell disease. This article presents a microfluidic-based approach with on-chip gas control for the impedance spectroscopy of suspended cells within the frequency range of 40 Hz to 110 MHz. A comprehensive bioimpedance of sickle cells under both normoxia and hypoxia is achieved rapidly (within ∼7 min) and is appropriated by small sample volumes (∼2.5 μL). Analysis of the sensing modeling is performed to obtain optimum conditions for dielectric spectroscopy of sickle cell suspensions and for extraction of single cell properties from the measured impedance spectra. The results of sickle cells show that upon hypoxia treatment, cell interior permittivity and conductivity increase, while cell membrane capacitance decreases. Moreover, the relative changes in cell dielectric parameters are found to be dependent on the sickle and fetal hemoglobin levels. In contrast, the changes in normal red blood cells between the hypoxia and normoxia states are unnoticeable. The results of sickle cells may serve as a reference to design dielectrophoresis-based cell sorting and electrodeformation testing devices that require cell dielectric characteristics as input parameters. The demonstrated method for dielectric characterization of single cells from the impedance spectroscopy of cell suspensions can be potentially applied to other cell types and under varied gas conditions.
Collapse
Affiliation(s)
- Jia Liu
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, USA
| | - Yuhao Qiang
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, USA
| | - E Du
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, FL, USA
| |
Collapse
|
14
|
Williams T, Bouazza-Marouf K, Zecca M, Green A. Analysis of the validity of the mathematical assumptions of electrical impedance tomography for human head tissues. Biomed Phys Eng Express 2021; 7. [PMID: 33513587 DOI: 10.1088/2057-1976/abe190] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 01/29/2021] [Indexed: 11/11/2022]
Abstract
Objective:To determine the validity of the key mathematical assumptions used in electrical impedance tomography for human head tissues over the frequency range of 10 Hz to 100 GHz.Approach:Conductivity and permittivity data collected from available literature for each tissue within the human head have been evaluated and critiqued. The most relevant dielectric tissue data for each tissue was then used to assess the validity of the mathematical assumptions of electrical impedance tomography in terms of their suitability for human head imaging in order to estimate related errors.Main Results:For induced currents with frequencies greater than 200 Hz the internal current source density is negligible. The assumption that magnetic effects are negligible is valid to an error of 1.7% for human head tissues for frequencies below 1 MHz. The capacitive effects are negligible for CSF, dura mater, blood, bone (cortical), and deep tissue skin for frequencies less than 3.2 MHz, 320 kHz, 25 kHz, 3.2 kHz, and 130 Hz respectively. However, the capacitive effects are not negligible for brain tissues, as the minimum error for brain tissues across the frequency range of 10 Hz to 100 GHz is 6.2% at 800 Hz, and the maximum error is 410% at 20 GHz.Significance:It is often assumed that the mathematical reduction of the base equations is valid for human head tissues over a broad frequency range; this study shows that these assumptions are not true for all tissues at all frequencies. False assumptions will result in greater errors and local distortions within tomographic images of the human head using electrical impedance tomography. This study provides the relationships between injected current frequency and the validity of the mathematical assumptions for each individual tissue, providing greater awareness of the magnitude of possible distortions.
Collapse
Affiliation(s)
- Toby Williams
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough University, Wolfson Building, Ashby Road, Loughborough, Leicestershire, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Kaddour Bouazza-Marouf
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough universtiy, Wolfson Building, Ashby Road, Loughborough, Leicestershire, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Massimiliano Zecca
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Michael Pearson (East), 1 Oakwood Drive, Loughborough University Science and Enterprise Park, Loughborough, Leicestershire, LE11 3QF, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Alex Green
- Nuffield Department of Surgical Sciences, University of Oxford, University of Oxford, Oxford, Oxfordshire, OX3 9DU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
15
|
Sabuncu AC, Muldur S, Cetin B, Usta OB, Aubry N. β-Dispersion of blood during sedimentation. Sci Rep 2021; 11:2642. [PMID: 33514847 PMCID: PMC7846779 DOI: 10.1038/s41598-021-82171-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Accepted: 01/08/2021] [Indexed: 01/30/2023] Open
Abstract
Aggregation of human red blood cells (RBC) is central to various pathological conditions from bacterial infections to cancer. When left at low shear conditions or at hemostasis, RBCs form aggregates, which resemble stacks of coins, known as 'rouleaux'. We experimentally examined the interfacial dielectric dispersion of aggregating RBCs. Hetastarch, an RBC aggregation agent, is used to mimic conditions leading to aggregation. Hetastrach concentration is incrementally increased in blood from healthy donors to measure the sensitivity of the technique. Time lapse electrical impedance measurements were conducted as red blood cells form rouleaux and sediment in a PDMS chamber. Theoretical modeling was used for obtaining complex permittivity of an effective single red blood cell aggregate at various concentrations of hetastarch. Time response of red blood cells' impedance was also studied to parametrize the time evolution of impedance data. Single aggregate permittivity at the onset of aggregation, evolution of interfacial dispersion parameters, and sedimentation kinetics allowed us to distinguish differential aggregation in blood.
Collapse
Affiliation(s)
- Ahmet C Sabuncu
- Mechanical Engineering Department, Worcester Polytechnic Institute, Worcester, MA, 01609, USA.
| | - Sinan Muldur
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School and Shriners Hospitals for Children, Boston, MA, 02114, USA
| | - Barbaros Cetin
- Microfluidics & Lab-On-a-Chip Research Group, Department of Mechanical Engineering, I.D. Bilkent University, Ankara, Turkey
| | - O Berk Usta
- Center for Engineering in Medicine, Massachusetts General Hospital, Harvard Medical School and Shriners Hospitals for Children, Boston, MA, 02114, USA
| | - Nadine Aubry
- School of Engineering, Tufts University, Medford, MA, 02155, USA
| |
Collapse
|
16
|
Ivanov IT, Paarvanova BK. Differential dielectroscopic data on the relation of erythrocyte membrane skeleton to erythrocyte deformability and flicker. EUROPEAN BIOPHYSICS JOURNAL : EBJ 2021; 50:69-86. [PMID: 33442752 DOI: 10.1007/s00249-020-01491-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 12/13/2020] [Accepted: 12/20/2020] [Indexed: 10/22/2022]
Abstract
Two dielectric relaxations, βsp (1.5 MHz) and γ1sp (7 MHz), have been detected on spectrin-based membrane skeleton (MS) of red blood cells (RBCs) using the plot of admittance changes at the spectrin denaturation temperature (Ivanov and Paarvanova in Bioelectrochemistry 110: 59-68, 2016, Electrochim Acta 317: 289-300, 2019a). In this study, we treated RBCs and RBC ghost membranes with agents that make membranes rigid and suppress membrane flicker, and studied the effect on βsp and γ1sp relaxations. Diamide (diazene dicarboxylic acid bis-(N,N-dimethylamide)) (up to 0.85 mM), taurine mustard (tris(2-chloroethyl)amine) (up to 2 mM), known to specifically cross-link and stiffen spectrin, and glutaraldehyde (up to 0.044%) all inhibited the relaxations in RBC ghost membranes. Similar inhibition was obtained resealing RBC ghost membranes with 2,3-diphosphoglicerate (up to 15 mM), binding WGA (wheat germ agglutinin) (up to 0.025 mg/ml) to exofacial aspect of RBCs, incubating RBCs in hypotonic (200 mOsm) and hypertonic (600-900 mOsm) media and depleting RBCs of ATP. By contrast, concanavalin A (1 mg/ml) and DIDS (4,4'-diiso-thiocyanato stilbene-2,2'-disulfonic acid) (75 μM, pH 8.2), both known to bind specifically band 3 integral protein of RBCs without effect on RBC membrane rigidity, did not affect the relaxations. We conclude there might be a relation between the strength of dielectric relaxations on MS spectrin and the deformability and flicker of RBC membrane.
Collapse
Affiliation(s)
- Ivan T Ivanov
- Department of Physics and Biophysics, Roentgenology and Radiology, Medical Faculty of Thracian University, 6000, Stara Zagora, Bulgaria.
| | - Boyana K Paarvanova
- Department of Physics and Biophysics, Roentgenology and Radiology, Medical Faculty of Thracian University, 6000, Stara Zagora, Bulgaria
| |
Collapse
|
17
|
Galpayage Dona KNU, Du E, Wei J. An impedimetric assay for the identification of abnormal mitochondrial dynamics in living cells. Electrophoresis 2020; 42:163-170. [PMID: 33169407 DOI: 10.1002/elps.202000125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 10/30/2020] [Accepted: 11/03/2020] [Indexed: 01/16/2023]
Abstract
Mitochondrial dynamics (fission and fusion) plays an important role in cell functions. Disruption in mitochondrial dynamics has been associated with diseases such as neurobiological disorders and cardiovascular diseases. Analysis of mitochondrial fission/fusion has been mostly achieved through direct visualization of the fission/fusion events in live-cell imaging of fluorescently labeled mitochondria. In this study, we demonstrated a label-free, non-invasive Electrical Impedance Spectroscopy (EIS) approach to analyze mitochondrial dynamics in a genetically modified human neuroblastoma SH-SY5Y cell line with no huntingtin protein expression. Huntingtin protein has been shown to regulate mitochondria dynamics. We performed EIS studies on normal SH-SY5Y cells and two independent clones of huntingtin-null cells. The impedance data was used to determine the suspension conductivity and further cytoplasmic conductivity and relate to the abnormal mitochondrial dynamics. For instance, the cytoplasm conductivity value was increased by 11% from huntingtin-null cells to normal cells. Results of this study demonstrated that EIS is sensitive to characterize the abnormal mitochondrial dynamics that can be difficult to quantify by the conventional microscopic method.
Collapse
Affiliation(s)
| | - E Du
- Department of Ocean and Mechanical Engineering, Florida Atlantic University, Boca Raton, Florida, USA
| | - Jianning Wei
- Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, Florida, USA
| |
Collapse
|
18
|
Temperature Correction to Enhance Blood Glucose Monitoring Accuracy Using Electrical Impedance Spectroscopy. SENSORS 2020; 20:s20216231. [PMID: 33142877 PMCID: PMC7663582 DOI: 10.3390/s20216231] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 10/23/2020] [Accepted: 10/24/2020] [Indexed: 11/20/2022]
Abstract
Electrical methods are among the primarily studied non-invasive glucose measurement techniques; however, various factors affect the accuracy of the sensors used. Of these, the temperature is a critical factor; hence, the effects of temperature on the electrical properties of blood components are investigated in this study. Furthermore, the changes in the electrical properties of blood according to the glucose level are corrected by considering the effects of temperature on the electrical properties. An impedance sensor is developed and used to measure whole blood impedance in 10 healthy participants at various temperatures and glucose levels. Subsequently, the conductivities of the plasma and cytoplasm were extracted. Changes in the electrical properties of the blood components are then analyzed using linear regression and repeated measures ANOVA. The electrical conductivities of plasma and cytoplasm increased with increasing temperatures (plasma: 0.0397 (slope), 0.7814 (R2), cytoplasm: 0.014 (slope), 0.694 (R2)). At three values of increasing glucose levels (85.4, 158.1, and 271.8 mg/dL), the electrical conductivities of the plasma and cytoplasm decreased. These tendencies are more significant upon temperature corrections (p-values; plasma: 0.001, 0.001, cytoplasm: 0.003, 0.002). The relationships between temperature and electrical conductivity changes can thus be used for temperature corrections in blood glucose measurement.
Collapse
|
19
|
Santorelli A, Fitzgerald S, Douglas A, Doyle K, O'Halloran M. Dielectric profile of blood clots to inform ischemic stroke treatments. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3723-3726. [PMID: 33018810 DOI: 10.1109/embc44109.2020.9175387] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Platelet and fibrin-rich blood clots can respond differently to red blood cell rich clots during ischemic stroke treatment, which includes thrombolysis and mechanical thrombectomy. Currently, there is no accurate way to identify the type of clot in advance of treatment. If the type of blood clot can be identified, the optimum clot removal process can be chosen and patient outcomes can be improved. In this paper we fabricate physiologically relevant blood clot analogues from human blood, that cover a range of red blood cell, fibrin, and platelet concentrations. We characterize the dielectric profile of these formed clots using an open-ended coaxial probe method across a wide frequency range. After the dielectric measurements are completed, histology on each blood clot is performed to determine the concentration of red blood cells present. In total, 32 unique blood clots were measured.With this completed analysis, we investigate the correlation between the dielectric properties across this frequency range and the red blood cell count of the formed blood clots. Furthermore, we develop a model to predict whether an unknown blood clot can be categorized as red blood cell rich or platelet and fibrin-rich based solely on the measured dielectric properties.Clinical Relevance-Using the dielectric profile of a clot we can predict whether a clot is platelet and fibrin-rich or red blood cell rich allowing clinicians to more easily determine treatment methods during an intervention for ischemic stroke.
Collapse
|
20
|
Abstract
At the end of the XX century, a new phenomenon was discovered by Ebbesen, the extraordinary optical transmission. He reported that metallic arrays composed of nano holes, also called nanoantennas, can support resonant optical transmissions responsible by the amplification and concentration of electromagnetic radiation. Classical diffraction theories do not predict this extraordinary phenomenon. This article shows the timeline of theories that try to model the interaction between light and metal planes with slits, holes, grooves or apertures. The comparison between theories is done. Furthermore, as the optical response of these nanoantennas is dependent on the complex dielectric function, there is a high probability of successfully using these structures as sensors. This article aimed to verify how the structure parameters (periodicity, hole diameter, nanoantenna thickness and substrate thickness) can influence the optical response in order to tune the spectrum. Using a Finite Element Tool, several 3D simulations aim to conclude about the parameters influence on air–gold–quartz and air–aluminum–quartz structures, being the nanoantenna made with gold and aluminum. Moreover, all the simulations allow us to verify a resonant spectral response and the existence of great values of amplification near the metal surface. This is a clear evidence of a energy exchange due to the generation and propagation of surface plasmon polaritons. Based on the spectra taken from the parameter analysis, a specific structure was chosen to test two different sensors. A temperature sensor and a tissue detection sensor were tested and the simulations are presented. It is concluded that a nanostructure based on a nanoantenna can be used as a sensor for several applications.
Collapse
|
21
|
Maji D, Opneja A, Suster MA, Bane KL, Wilson BM, Mohseni P, Stavrou EX. Monitoring DOACs with a Novel Dielectric Microsensor: A Clinical Study. Thromb Haemost 2020; 121:58-69. [PMID: 32877954 DOI: 10.1055/s-0040-1715589] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND There are acute settings where assessing the anticoagulant effect of direct oral anticoagulants (DOACs) can be useful. Due to variability among routine coagulation tests, there is an unmet need for an assay that detects DOAC effects within minutes in the laboratory or at the point of care. METHODS We developed a novel dielectric microsensor, termed ClotChip, and previously showed that the time to reach peak permittivity (T peak) is a sensitive parameter of coagulation function. We conducted a prospective, single-center, pilot study to determine its clinical utility at detecting DOAC anticoagulant effects in whole blood. RESULTS We accrued 154 individuals: 50 healthy volunteers, 49 rivaroxaban patients, 47 apixaban, and 8 dabigatran patients. Blood samples underwent ClotChip measurements and plasma coagulation tests. Control mean T peak was 428 seconds (95% confidence interval [CI]: 401-455 seconds). For rivaroxaban, mean T peak was 592 seconds (95% CI: 550-634 seconds). A receiver operating characteristic curve showed that the area under the curve (AUC) predicting rivaroxaban using T peak was 0.83 (95% CI: 0.75-0.91, p < 0.01). For apixaban, mean T peak was 594 seconds (95% CI: 548-639 seconds); AUC was 0.82 (95% CI: 0.73-0.91, p < 0.01). For dabigatran, mean T peak was 894 seconds (95% CI: 701-1,086 seconds); AUC was 1 (p < 0.01). Specificity for all DOACs was 88%; sensitivity ranged from 72 to 100%. CONCLUSION This diagnostic study using samples from "real-world" DOAC patients supports that ClotChip exhibits high sensitivity at detecting DOAC anticoagulant effects in a disposable portable platform, using a miniscule amount of whole blood (<10 µL).
Collapse
Affiliation(s)
- Debnath Maji
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Aman Opneja
- Hematology and Oncology Division, Department of Medicine, University Hospitals Cleveland Medical Center, Cleveland, Ohio, United States.,Division of Hematology-Oncology, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio, United States
| | - Michael A Suster
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Kara L Bane
- Division of Hematology-Oncology, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio, United States
| | - Brigid M Wilson
- Geriatric Research Education and Clinical Center, Louis Stokes Cleveland Veterans Administration Medical Center, VA Northeast Ohio Healthcare System, Cleveland, Ohio, United States.,Division of Infectious Diseases and HIV Medicine, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio, United States
| | - Pedram Mohseni
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, Ohio, United States
| | - Evi X Stavrou
- Division of Hematology-Oncology, Department of Medicine, Case Western Reserve University School of Medicine, Cleveland, Ohio, United States.,Section of Hematology-Oncology, Department of Medicine, Louis Stokes Cleveland Veterans Administration Medical Center, VA Northeast Ohio Healthcare System, Cleveland, Ohio, United States
| |
Collapse
|
22
|
Martins ML, Bordallo HN, Arrese-Igor S, Alegría A, Colmenero de Leon J. Effect of Paclitaxel in the Water Dynamics of MCF-7 Breast Cancer Cells Revealed by Dielectric Spectroscopy. ACS OMEGA 2020; 5:18602-18607. [PMID: 32775862 PMCID: PMC7407532 DOI: 10.1021/acsomega.0c00897] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 06/25/2020] [Indexed: 06/11/2023]
Abstract
Using dielectric spectroscopy experiments performed at multiple temperatures and frequency ranges, we demonstrate how the chemotherapy drug paclitaxel changes the dynamic properties of water in a breast cancer cell line (MCF-7). From the measured data, we present evidence that treatment with paclitaxel leads to a slight increase in activation energy in a relaxation related to bulk-like water. More importantly, we also observe that paclitaxel changes the constraining imposed by the biological interfaces on hydration water, whose single-particle dynamics becomes slower and with higher activation energy. These variations are only observable after freezing the dynamics from other cellular components, such as proteins and DNAs, regardless of the state of the cells, that is, treated or not treated or even if the cells are no longer viable. Therefore, changes in water dynamics could be detected prior to those related to the global dynamics within the cellular environment.
Collapse
Affiliation(s)
- Murillo L. Martins
- System
and Production Engineering Graduate Program, Pontifical Catholic University of Goias, 74605-010 Goiania, Brazil
| | - Heloisa N. Bordallo
- Niels
Bohr Institute, University of Copenhagen, DK-2100 Copenhagen, Denmark
- European
Spallation Source, P.O. Box 176, SE-221 00 Lund, Sweden
| | - Silvia Arrese-Igor
- Centro
de Física de Materiales, Centro Mixto
CSIC-UPV/EHU, Paseo Manuel
Lardizabal 5, 20018 San Sebastián, Spain
| | - Angel Alegría
- Centro
de Física de Materiales, Centro Mixto
CSIC-UPV/EHU, Paseo Manuel
Lardizabal 5, 20018 San Sebastián, Spain
| | - Juan Colmenero de Leon
- Centro
de Física de Materiales, Centro Mixto
CSIC-UPV/EHU, Paseo Manuel
Lardizabal 5, 20018 San Sebastián, Spain
| |
Collapse
|
23
|
Kim J, Song W, Jung S, Kim Y, Park W, You B, Park K. Capacitive Heart-Rate Sensing on Touch Screen Panel with Laterally Interspaced Electrodes. SENSORS 2020; 20:s20143986. [PMID: 32709061 PMCID: PMC7412254 DOI: 10.3390/s20143986] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 07/11/2020] [Accepted: 07/13/2020] [Indexed: 11/16/2022]
Abstract
It is demonstrated that the heart-rate can be sensed capacitively on a touch screen panel (TSP) together with touch signals. The existing heart-rate sensing systems measure blood pulses by tracing the amount of light reflected from blood vessels during a number of cardiac cycles. This type of sensing system requires a considerable amount of power and space to be implemented in multi-functional mobile devices such as smart phones. It is found that the variation of the effective dielectric constant of finger stemming from the difference of systolic and diastolic blood flows can be measured with laterally interspaced top electrodes of TSP. The spacing between a pair of non-adjacent top electrodes turns out to be wide enough to distinguish heart-rate signals from noises. With the aid of fast Fourier transform, the heart-rate can be extracted reliably, which matches with the one obtained by actually counting heart beats on the wrist.
Collapse
Affiliation(s)
- Junhyung Kim
- School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea;
| | - Wonho Song
- Department of Physics, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea;
| | | | - Yuna Kim
- Samsung Display Giheung Campus, Yongin-si, Gyeonggi-do 17113, Korea; (Y.K.); (W.P.); (B.Y.)
| | - Wonsang Park
- Samsung Display Giheung Campus, Yongin-si, Gyeonggi-do 17113, Korea; (Y.K.); (W.P.); (B.Y.)
| | - Bonghyun You
- Samsung Display Giheung Campus, Yongin-si, Gyeonggi-do 17113, Korea; (Y.K.); (W.P.); (B.Y.)
| | - Kibog Park
- School of Electrical and Computer Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea;
- Department of Physics, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Korea;
- Correspondence: ; Tel.: +(82)-052-217-2111
| |
Collapse
|
24
|
Windberger U, Dibiasi C, Lotz EM, Scharbert G, Reinbacher-Koestinger A, Ivanov I, Ploszczanski L, Antonova N, Lichtenegger H. The effect of hematocrit, fibrinogen concentration and temperature on the kinetics of clot formation of whole blood. Clin Hemorheol Microcirc 2020; 75:431-445. [PMID: 32390608 DOI: 10.3233/ch-190799] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Dynamic mechanical analysis of blood clots can be used to detect the coagulability of blood. OBJECTIVE We investigated the kinetics of clot formation by changing several blood components, and we looked into the clot "signature" at its equilibrium state by using viscoelastic and dielectric protocols. METHODS Oscillating shear rheometry, ROTEM, and a dielectro-rheological device was used. RESULTS In fibrinogen- spiked samples we found the classical high clotting ability: shortened onset, faster rate of clotting, and higher plateau stiffness. Electron microscopy explained the gain of stiffness. Incorporated RBCs weakened the clots. Reduction of temperature during the clotting process supported the development of high moduli by providing more time for fiber assembly. But at low HCT, clot firmness could be increased by elevating the temperature from 32 to 37°C. In contrast, when the fibrinogen concentration was modified, acceleration of clotting via temperature always reduced clot stiffness, whatever the initial fibrinogen concentration. Electrical resistance increased continuously during clotting; loss tangent (D) (relaxation frequency 249 kHz) decreased when clots became denser: fewer dipoles contributed to the relaxation process. The relaxation peak (Dmax) shifted to lower frequencies at higher platelet count. CONCLUSION Increasing temperature accelerates clot formation but weakens clots. Rheometry and ROTEM correlate well.
Collapse
Affiliation(s)
- U Windberger
- Center for Biomedical Research, Medical University Vienna, Vienna, Austria
| | - Ch Dibiasi
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - E M Lotz
- Center for Biomedical Research, Medical University Vienna, Vienna, Austria
| | - G Scharbert
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - A Reinbacher-Koestinger
- Institute of Fundamentals and Theory in Electrical Engineering, Graz University of Technology, Graz, Austria
| | - I Ivanov
- Institute of Mechanics, Bulgarian Academy of Science, Sofia, Bulgaria
| | - L Ploszczanski
- Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria
| | - N Antonova
- Institute of Mechanics, Bulgarian Academy of Science, Sofia, Bulgaria
| | - H Lichtenegger
- Department of Material Sciences and Process Engineering, Institute of Physics and Materials Science, University of Natural Resources and Life Sciences, Vienna, Austria
| |
Collapse
|
25
|
Zhbanov A, Yang S. Electrochemical Impedance Characterization of Blood Cell Suspensions-Part 2: Three-Phase Systems With Single-Shelled Particles. IEEE Trans Biomed Eng 2020; 67:2979-2989. [PMID: 32091989 DOI: 10.1109/tbme.2020.2975816] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The analyses presented in Part 1 are expanded to three-phase composite materials. The theory developed in Part 1 is used for analytical and numerical calculations of dielectric spectra. In this study, three-phase systems with single-shelled particles were considered. The disordered particle distribution, aligned orientation of particles, and particles placed in different lattice structures are studied. It is shown that both two-phase and three-phase composites exhibit β-dispersion, while three-phase composites additionally exhibit δ-dispersion. This is the fundamental difference in the spectra for two- and three-phase materials. In the case of aligned orientation, the effective permittivity in the direction perpendicular to the spheroid plane exhibits a maximum at a volume fraction of approximately 0.5. Both two- and three-phase materials display this behavior. This may be of interest for the development of new metamaterials. The dielectric properties of composite materials with random distribution and periodic arrangement of particles differ significantly. The dielectric spectrum of erythrocyte suspension in plasma was measured by means of electrochemical impedance spectroscopy. The measurement system consisted of a small chamber with two planar electrodes placed at the bottom and an impedance analyzer. The dielectric properties of erythrocyte cytoplasm and membrane were numerically determined based on experimental data. The measurement of the dielectric properties of whole blood and blood components is very promising for various medical applications.
Collapse
|
26
|
Zhbanov A, Yang S. Electrochemical Impedance Characterization of Blood Cell Suspensions. Part 1: Basic Theory and Application to Two-Phase Systems. IEEE Trans Biomed Eng 2020; 67:2965-2978. [PMID: 32078529 DOI: 10.1109/tbme.2020.2974480] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Electrochemical impedance spectra of composite materials contain information on the topological arrangement, volume fraction, and shape of particles, as well as the dielectric properties of the matrix and particles. The objective of this study is to investigate how these parameters affect the dielectric spectrum and what reliable information can be extracted from experimental data. The main attention was focused on systems with dielectric behavior similar to that of human blood. Mostly plasma and erythrocytes determine the dielectric properties of whole blood. Erythrocytes suspended in plasma can be considered as three-phase systems with single-shelled particles. A theoretical approach based on the effective medium theory is developed for calculating the effective permittivity and conductivity of three-phase composites at a wide frequency range (from 0 to 1 GHz). A finite-difference method is applied to model three-dimensional periodic structures. A special case of two-phase materials is used to demonstrate the influence of the shape and arrangement of particles on dielectric properties. Theoretical and numerical approaches are applied to two-phase composites with spherical, spheroidal and biconcave particles and are compared with each other and with published data. It is shown that two-phase composites exhibit only β-dispersion. In contrast to the quasi-static limit, the wide-bandwidth impedance spectroscopy makes it possible to distinguish between disordered and regular arrangements of spheroidal and biconcave particles. The results can be used to analyze the dielectric properties of blood, which is very promising for various medical applications. This study of two-phase composites can be further extended to three-phase composites.
Collapse
|
27
|
Duan L, Lv X, He Q, Ji X, Sun M, Yang Y, Ji Z, Xie Y. Geometry-on-demand fabrication of conductive microstructures by photoetching and application in hemostasis assessment. Biosens Bioelectron 2020; 150:111886. [PMID: 31784313 DOI: 10.1016/j.bios.2019.111886] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Revised: 11/12/2019] [Accepted: 11/13/2019] [Indexed: 10/25/2022]
Abstract
Photo-corrosion is a common phenomenon observed in the photocatalytic semiconductor materials, which can seriously harm the photoelectric properties and performances in the energy applications. However, in this paper, we demonstrated that the photo-corrosion effects can be used for the microfabrication of conductive structures on a photocatalytic film like zinc oxide (ZnO), named as "photoetching". Our results demonstrated that microstructures can be prepared within seconds with a precision at an order of tens of micrometers using our current devices. Different from the previous work, the etching process was achieved free of conducting layer under the ZnO film, avoiding the short-circuit of the conductive micro-patterns and enabling the use for the impedance sensing. We demonstrated the fabricated ZnO microelectrode pairs can work for the electrochemical impedance measurements like assessment of hemostasis integrated with a microfluidic chip. Compared to the noble metal microelectrodes, the ZnO conductive microelectrodes can be fabricated within seconds and the low costs make it possible as a disposable diagnostic device. Besides, the photoetching technique can be performed without a cleanroom reducing the technical barriers, possibly helpful for the low resources areas. We believe the simplicity of device, low costs and fast fabrication can be useful in the relevant fields such as biomedical and energy harvesting, especially for low resources areas.
Collapse
Affiliation(s)
- Libing Duan
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China.
| | - Xinjun Lv
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Qian He
- Department of Clinical Laboratory, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004, China
| | - Xiangyang Ji
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Miao Sun
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Yajie Yang
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Zhenming Ji
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Yanbo Xie
- MOE Key Laboratory of Material Physics and Chemistry under Extraordinary Conditions, School of Physical Science and Technology, Northwestern Polytechnical University, Xi'an, 710072, China.
| |
Collapse
|
28
|
Quick, Single-Frequency Dielectric Characterization of Blood Samples of Pediatric Cancer Patients by a Cylindrical Capacitor: Pilot Study. ELECTRONICS 2020. [DOI: 10.3390/electronics9010095] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
In this paper, as an application in biometrics, the electrical capacitance of normal and cancerous blood samples is experimentally determined in order to test the null hypothesis that the electrical capacitance of the two samples differs. The samples taken from healthy donors and patients diagnosed with different types of hematologic cancer are examined by a cylindrical capacitor with blood as its dielectric. The capacitance of these samples is measured at room temperature and a single frequency of 120 Hz, well below the frequency where β -dispersion starts, using a simple LCR meter device. The measurements indicate that the capacitance of the blood increases under applied electric field for a short period of time and asymptotically reaches its steady-state value. The measured values for the healthy group agreed with previous data in the literature. By the use of the unpaired two-tailed T-test, it is found that cancerous blood has higher values of capacitance when compared to normal samples ( p < 0.05 ). The reasons that might lead to such alterations are discussed from a biological perspective. Moreover, based on correlation calculations, a strong negative association is observed between blood capacitance and red blood cell (RBC) count in each group. Furthermore, sensitivity (SE) and specificity (SP) analysis demonstrates that for a threshold value between 15 and 17 for the capacitance value, both SE and SP are 100%. These preliminary findings on capacitance values may pave the way for the development of inexpensive and easy-to-use diagnosis tools for hematologic cancers at medical facilities and for in-home use, especially for children.
Collapse
|
29
|
Nasir N, Raji S, Mustafa F, Rizvi TA, Al Natour Z, Hilal-Alnaqbi A, Al Ahmad M. Electrical detection of blood cells in urine. Heliyon 2019; 6:e03102. [PMID: 31909269 PMCID: PMC6938827 DOI: 10.1016/j.heliyon.2019.e03102] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 11/21/2019] [Accepted: 12/18/2019] [Indexed: 12/12/2022] Open
Abstract
Available methods for detecting blood in the urine (hematuria) can be problematic since results can be influenced by many factors in patients and in the lab settings, resulting in false positive or false negative results. This necessitates the development of new, accurate and easy-access methods that save time and effort. This study demonstrates a label-free and accurate method for detecting the presence of red and white blood cells (RBCs and WBCs) in urine by measuring the changes in the dielectric properties of urine upon increasing concentrations of both cell types. The current method could detect changes in the electrical properties of fresh urine over a short time interval, making this method suitable for detecting changes that cannot be recognized by conventional methods. Correcting for these changes enabled the detection of a minimum cell concentration of 102 RBCs per ml which is not possible by conventional methods used in the labs except for the semi-quantitative method that can detect 50 RBCs per ml, but it is a lengthy and involved procedure, not suitable for high volume labs. This ability to detect very small amount of both types of cells makes the proposed technique an attractive tool for detecting hematuria, the presence of which is indicative of problems in the excretory system.
Collapse
Affiliation(s)
- Nida Nasir
- Department of Electrical Engineering, College of Engineering, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Shaima Raji
- Department of Electrical Engineering, College of Engineering, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Farah Mustafa
- Department of Biochemistry, College of Medicine & Health Sciences, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Tahir A Rizvi
- Department of Microbiology and Immunology, College of Medicine & Health Sciences, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Zeina Al Natour
- Department of Electrical Engineering, College of Engineering, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Ali Hilal-Alnaqbi
- Department of Mechanical Engineering, College of Engineering, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Abu Dhabi Polytechnic, Abu Dhabi, 1114999, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| | - Mahmoud Al Ahmad
- Department of Electrical Engineering, College of Engineering, United Arab Emirates University (UAEU), Al Ain, 15551, United Arab Emirates.,Zayed Center for Health Sciences, United Arab Emirates University, United Arab Emirates
| |
Collapse
|
30
|
Caduff A, Ben Ishai P, Feldman Y. Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo. Biophys Rev 2019; 11:1017-1035. [PMID: 31741172 DOI: 10.1007/s12551-019-00601-7] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 10/13/2019] [Indexed: 01/22/2023] Open
Abstract
With diabetes set to become the number 3 killer in the Western hemisphere and proportionally growing in other parts of the world, the subject of noninvasive monitoring of glucose dynamics in blood remains a "hot" topic, with the involvement of many groups worldwide. There is a plethora of techniques involved in this academic push, but the so-called multisensor system with an impedance-based core seems to feature increasingly strongly. However, the symmetrical structure of the glucose molecule and its shielding by the smaller dipoles of water would suggest that this option should be less enticing. Yet there is enough phenomenological evidence to suggest that impedance-based methods are truly sensitive to the biophysical effects of glucose variations in the blood. We have been trying to answer this very fundamental conundrum: "Why is impedance or dielectric spectroscopy sensitive to glucose concentration changes in the blood and why can this be done over a very broad frequency band, including microwaves?" The vistas for medical diagnostics are very enticing. There have been a significant number of papers published that look seriously at this problem. In this review, we want to summarize this body of research and the underlying mechanisms and propose a perspective toward utilizing the phenomena. It is our impression that the current world view on the dielectric response of glucose in solution, as outlined below, will support the further evolution and implementation toward practical noninvasive glucose monitoring solutions.
Collapse
Affiliation(s)
- Andreas Caduff
- Applied Physics Department and the Center for Electromagnetic Research and Characterization, The Hebrew University of Jerusalem, 91904, Jerusalem, Israel
| | - Paul Ben Ishai
- Department of Physics, Ariel University, 40700, Ariel, Israel
| | - Yuri Feldman
- Applied Physics Department and the Center for Electromagnetic Research and Characterization, The Hebrew University of Jerusalem, 91904, Jerusalem, Israel.
| |
Collapse
|
31
|
Fischer G, Handler M, Johnston PR, Baumgarten D. Impedance and conductivity of bovine myocardium during freezing and thawing at slow rates - implications for cardiac cryo-ablation. Med Eng Phys 2019; 74:89-98. [PMID: 31570217 DOI: 10.1016/j.medengphy.2019.09.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 09/12/2019] [Accepted: 09/16/2019] [Indexed: 01/19/2023]
Abstract
Increasing impedance during freezing might be a valuable marker for guiding cardiac cryo-ablation. We provide model based insights on how decreasing temperature below the freezing point of tissue relates to the percentage of frozen water. Furthermore, we provide experimental data for comparing this percentage with the increase in impedance. Measurements were performed on a bovine tissue sample at frequencies between 5 and 80 kHz. Slow cooling and heating rates were applied to minimize temperature gradients in the myocardial sample and to allow accurate assessment of the freezing point. Computer simulation was applied to link impedance with temperature dependent conductivities. The osmotic virial equation was used to estimate the percentage of frozen water. Measurements identified the freezing point at -0.6 ∘C. At -5 ∘C, impedance rose by more than a factor of ten compared to that at the freezing point and the percentage of frozen water was estimated as being 89%. At -49 ∘C impedance had increased by up to three orders of magnitude and ice formation was most pronounced in the extracellular space. Progressive ice formation in tissue is reflected by a large increase in impedance, and impedance increases monotonically with the percentage of frozen water. Its analysis allows for experimental assessment of factors relevant to cell death. Solid ice contributes to the rupture of the micro-vasculature, while phase shifts reflect concentration differences between extra- and intracellular space driving osmotic water transfer across cell membranes.
Collapse
Affiliation(s)
- G Fischer
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Eduard-Wallnoefer-Zentrum 1, Hall in Tyrol 6060, Austria; AFreeze GmbH, Innsbruck, Austria.
| | - M Handler
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Eduard-Wallnoefer-Zentrum 1, Hall in Tyrol 6060, Austria; School of Environment and Science, Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland, Australia
| | - P R Johnston
- School of Environment and Science, Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, Queensland, Australia
| | - D Baumgarten
- Institute of Electrical and Biomedical Engineering, UMIT - Private University for Health Sciences, Medical Informatics and Technology, Eduard-Wallnoefer-Zentrum 1, Hall in Tyrol 6060, Austria; Institute of Electrical and Biomedical Engineering, Technische Universität Ilmenau, Ilmenau, Germany
| |
Collapse
|
32
|
|
33
|
Santorelli A, O'Halloran M. Patient-Specific Debye Parameters for Human Blood. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2019:238-242. [PMID: 31945886 DOI: 10.1109/embc.2019.8856388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This paper develops a patient-specific model for the Debye parameters of human blood based on hemoglobin content. Blood samples were collected from 176 patients visiting the University Hospital, with both permittivity measurements and standard hematological analysis performed on each blood draw. The complete blood count of each sample provided information on the hemoglobin concentration of each sample; in total there were 73 distinct hemoglobin concentrations reported. An iterative process was used to find patient-specific, based on hemoglobin content, Debye parameters. First, a two-stage genetic algorithm was used to solve for the parameters of a two-pole Debye model based on the mean-blood properties. Then, a modified two-pole Debye model incorporating hemoglobin information was developed, and those parameters were solved for using the same two-stage genetic algorithm. This paper presents the parameters for both the mean-blood model and the patient-specific model. The patient-specific model has a mean-fractional error across all 73 samples of 3.41% compared to 7.64% when using the mean-blood model to represent the entire population. This work demonstrates the range in the dielectric properties of human blood samples and highlights the need for incorporating patient-specific information when using the Debye parameters to model the dielectric properties of human blood.
Collapse
|
34
|
Ultra-Wideband Temperature Dependent Dielectric Spectroscopy of Porcine Tissue and Blood in the Microwave Frequency Range. SENSORS 2019; 19:s19071707. [PMID: 30974770 PMCID: PMC6479484 DOI: 10.3390/s19071707] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 03/22/2019] [Accepted: 04/04/2019] [Indexed: 12/20/2022]
Abstract
The knowledge of frequency and temperature dependent dielectric properties of tissue is essential to develop ultra-wideband diagnostic technologies, such as a non-invasive temperature monitoring system during hyperthermia treatment. To this end, we characterized the dielectric properties of animal liver, muscle, fat and blood in the microwave frequency range from 0.5 GHz to 7 GHz and in the temperature range between 30 °C and 50 °C. The measured data were modeled to a two-pole Cole-Cole model and a second-order polynomial was introduced to fit the Cole-Cole parameters as a function of temperature. The parametric model provides access to the dielectric properties of tissue at any frequency and temperature in the specified range.
Collapse
|
35
|
Alternating Electric Fields (TTFields) Activate Ca v1.2 Channels in Human Glioblastoma Cells. Cancers (Basel) 2019; 11:cancers11010110. [PMID: 30669316 PMCID: PMC6356873 DOI: 10.3390/cancers11010110] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 12/16/2018] [Accepted: 01/15/2019] [Indexed: 12/12/2022] Open
Abstract
Tumor treating fields (TTFields) represent a novel FDA-approved treatment modality for patients with newly diagnosed or recurrent glioblastoma multiforme. This therapy applies intermediate frequency alternating electric fields with low intensity to the tumor volume by the use of non-invasive transducer electrode arrays. Mechanistically, TTFields have been proposed to impair formation of the mitotic spindle apparatus and cytokinesis. In order to identify further potential molecular targets, here the effects of TTFields on Ca2+-signaling, ion channel activity in the plasma membrane, cell cycle, cell death, and clonogenic survival were tested in two human glioblastoma cell lines in vitro by fura-2 Ca2+ imaging, patch-clamp cell-attached recordings, flow cytometry and pre-plated colony formation assay. In addition, the expression of voltage-gated Ca2+ (Cav) channels was determined by real-time RT-PCR and their significance for the cellular TTFields response defined by knock-down and pharmacological blockade. As a result, TTFields stimulated in a cell line-dependent manner a Cav1.2-mediated Ca2+ entry, G1 or S phase cell cycle arrest, breakdown of the inner mitochondrial membrane potential and DNA degradation, and/or decline of clonogenic survival suggesting a tumoricidal action of TTFields. Moreover, inhibition of Cav1.2 by benidipine aggravated in one glioblastoma line the TTFields effects suggesting that Cav1.2-triggered signaling contributes to cellular TTFields stress response. In conclusion, the present study identified Cav1.2 channels as TTFields target in the plasma membrane and provides the rationale to combine TTFields therapy with Ca2+ antagonists that are already in clinical use.
Collapse
|
36
|
Halonen S, Kari J, Ahonen P, Kronström K, Hyttinen J. Real-Time Bioimpedance-Based Biopsy Needle Can Identify Tissue Type with High Spatial Accuracy. Ann Biomed Eng 2018; 47:836-851. [DOI: 10.1007/s10439-018-02187-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 12/08/2018] [Indexed: 11/29/2022]
|
37
|
Maji D, De La Fuente M, Kucukal E, Sekhon UDS, Schmaier AH, Sen Gupta A, Gurkan UA, Nieman MT, Stavrou EX, Mohseni P, Suster MA. Assessment of whole blood coagulation with a microfluidic dielectric sensor. J Thromb Haemost 2018; 16:2050-2056. [PMID: 30007048 PMCID: PMC6173630 DOI: 10.1111/jth.14244] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Indexed: 12/12/2022]
Abstract
Essentials ClotChip is a novel microsensor for comprehensive assessment of ex vivo hemostasis. Clinical samples show high sensitivity to detecting the entire hemostatic process. ClotChip readout exhibits distinct information on coagulation factor and platelet abnormalities. ClotChip has potential as a point-of-care platform for comprehensive hemostatic analysis. SUMMARY Background Rapid point-of-care (POC) assessment of hemostasis is clinically important in patients with a variety of coagulation factor and platelet defects who have bleeding disorders. Objective To evaluate a novel dielectric microsensor, termed ClotChip, which is based on the electrical technique of dielectric spectroscopy for rapid, comprehensive assessment of whole blood coagulation. Methods The ClotChip is a three-dimensional, parallel-plate, capacitive sensor integrated into a single-use microfluidic channel with miniscule sample volume (< 10 μL). The ClotChip readout is defined as the temporal variation in the real part of dielectric permittivity of whole blood at 1 MHz. Results The ClotChip readout exhibits two distinct parameters, namely, the time to reach a permittivity peak (Tpeak ) and the maximum change in permittivity after the peak (Δεr,max ), which are, respectively, sensitive towards detecting non-cellular (i.e. coagulation factor) and cellular (i.e. platelet) abnormalities in the hemostatic process. We evaluated the performance of ClotChip using clinical blood samples from 15 healthy volunteers and 12 patients suffering from coagulation defects. The ClotChip Tpeak parameter exhibited superior sensitivity at distinguishing coagulation disorders as compared with conventional screening coagulation tests. Moreover, the ClotChip Δεr,max parameter detected platelet function inhibition induced by aspirin and exhibited strong positive correlation with light transmission aggregometry. Conclusions This study demonstrates that ClotChip assesses multiple aspects of the hemostatic process in whole blood on a single disposable cartridge, highlighting its potential as a POC platform for rapid, comprehensive hemostatic analysis.
Collapse
Affiliation(s)
- D Maji
- Electrical Engineering and Computer Science Department, Case Western Reserve University, Cleveland, OH, USA
| | - M De La Fuente
- Department of Pharmacology, Case Western Reserve University, Cleveland, OH, USA
| | - E Kucukal
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - U D S Sekhon
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - A H Schmaier
- Department of Medicine, Hematology and Oncology Division, University Hospitals Cleveland Medical Center, Cleveland, OH, USA
- Department of Medicine, Hematology and Oncology Division, Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | - A Sen Gupta
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - U A Gurkan
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, Cleveland, OH, USA
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - M T Nieman
- Department of Pharmacology, Case Western Reserve University, Cleveland, OH, USA
| | - E X Stavrou
- Department of Medicine, Louis Stokes Veterans Administration Medical Center, Cleveland, OH, USA
- Department of Medicine, Hematology and Oncology Division, Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | - P Mohseni
- Electrical Engineering and Computer Science Department, Case Western Reserve University, Cleveland, OH, USA
| | - M A Suster
- Electrical Engineering and Computer Science Department, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
38
|
Elwan AM, Salama AA, Sayed AM, Ghoneim AM, Assaied AA, Ibrahim FA, Shousha HA, Elnasharty MMM. Response of rats to dose rates of ionizing radiation evaluated by dielectric properties of bone marrow. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2018; 140:124-132. [PMID: 29776659 DOI: 10.1016/j.pbiomolbio.2018.05.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2017] [Revised: 04/21/2018] [Accepted: 05/09/2018] [Indexed: 12/23/2022]
Abstract
The response of adult Wistar albino female rats toward two dose rates of gamma radiation delivered as acute dose of 7 Gy is investigated using classical methodologies as chemical, hematological and histological parameters in comparison with newly introduced dielectric parameters. Two groups of rats were exposed to γ ray with dose rates 533.35 mGy/min and 325.89 mGy/min. Then the irradiated groups were followed up for two weeks after irradiation. In case of higher dose rate, high percentage of animals was lost and there were substantial alterations in the dielectric parameters in addition to massive damage in liver and bone marrow cells. On the other hand, a reduction of death rate of rats, different behavior in the dielectric parameters of bone marrow and lesser injury of liver tissue were well noticeable in case of lower dose rate. Moreover, the sensitivity of dielectric parameters toward the two different dose rates was well pronounced during the 1st and 2nd weeks after irradiation more than other parameters.
Collapse
Affiliation(s)
- Azhar M Elwan
- Dept., of Biochemistry, National Research Centre (NRC), 33 El Bohouth st., Dokki, Giza, P.O.12622, Egypt.
| | - Aida A Salama
- Dept., of Physics, Faculty of Science, Al-Azhar University, Nasr City, Cairo, P.O.11651, Egypt
| | - Abdelbaset M Sayed
- Dept., of Biochemistry, National Research Centre (NRC), 33 El Bohouth st., Dokki, Giza, P.O.12622, Egypt
| | - Ahmad M Ghoneim
- Dept., of Microwave Physics& Dielectrics, National Research Centre (NRC), 33 El Bohouth st., Dokki, Giza, P.O.12622, Egypt
| | - Aziza A Assaied
- Dept., of Physics, Faculty of Science, Al-Azhar University, Nasr City, Cairo, P.O.11651, Egypt
| | - Fatma A Ibrahim
- Dept., of Biochemistry, National Research Centre (NRC), 33 El Bohouth st., Dokki, Giza, P.O.12622, Egypt
| | - Hany A Shousha
- Dept., of Radiation Dosimetry, National Institute of Standards, Tersa Street, Giza, Egypt
| | - Mohamed M M Elnasharty
- Dept., of Microwave Physics& Dielectrics, National Research Centre (NRC), 33 El Bohouth st., Dokki, Giza, P.O.12622, Egypt
| |
Collapse
|
39
|
Hayashi Y, Brun MA, Machida K, Lee S, Murata A, Omori S, Uchiyama H, Inoue Y, Kudo T, Toyofuku T, Nagasawa M, Uchimura I, Nakamura T, Muneta T. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry. Biorheology 2018; 54:25-35. [PMID: 28800301 PMCID: PMC5676769 DOI: 10.3233/bir-16118] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
BACKGROUND In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. OBJECTIVE The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. METHODS Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. RESULTS Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). CONCLUSIONS Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability.
Collapse
Affiliation(s)
- Yoshihito Hayashi
- LE Development Department, R&D Division, Medical Business Unit, Imaging Products & Solutions Sector, Sony Corporation, Tokyo, Japan
| | - Marc-Aurèle Brun
- Life Science Department, Biomedical R&D Division, RDS Platform, Sony Corporation, Tokyo, Japan
| | - Kenzo Machida
- LE Development Department, R&D Division, Medical Business Unit, Imaging Products & Solutions Sector, Sony Corporation, Tokyo, Japan
| | - Seungmin Lee
- LE Development Department, R&D Division, Medical Business Unit, Imaging Products & Solutions Sector, Sony Corporation, Tokyo, Japan
| | - Aya Murata
- LE Development Department, R&D Division, Medical Business Unit, Imaging Products & Solutions Sector, Sony Corporation, Tokyo, Japan
| | - Shinji Omori
- LE Development Department, R&D Division, Medical Business Unit, Imaging Products & Solutions Sector, Sony Corporation, Tokyo, Japan
| | - Hidetoshi Uchiyama
- Department of Surgical Specialities, Tokyo Medical and Dental University Graduate School, Tokyo, Japan
| | - Yoshinori Inoue
- Department of Surgical Specialities, Tokyo Medical and Dental University Graduate School, Tokyo, Japan
| | - Toshifumi Kudo
- Department of Surgical Specialities, Tokyo Medical and Dental University Graduate School, Tokyo, Japan
| | - Takahiro Toyofuku
- Department of Surgical Specialities, Tokyo Medical and Dental University Graduate School, Tokyo, Japan
| | - Masayuki Nagasawa
- Department of Pediatrics, Tokyo Medical and Dental University, Tokyo, Japan.,Department of Pediatrics, Musashino Red Cross Hospital, Musashino-city, Tokyo, Japan
| | - Isao Uchimura
- Department of Endocrinology and Metabolism, Tokyo Medical and Dental University, Tokyo, Japan
| | - Tomomasa Nakamura
- Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| | - Takeshi Muneta
- Department of Orthopaedic Surgery, Tokyo Medical and Dental University Hospital, Tokyo, Japan
| |
Collapse
|
40
|
Maji D, Suster MA, Kucukal E, Sekhon UDS, Gupta AS, Gurkan UA, Stavrou EX, Mohseni P. ClotChip: A Microfluidic Dielectric Sensor for Point-of-Care Assessment of Hemostasis. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:1459-1469. [PMID: 28920906 PMCID: PMC6091230 DOI: 10.1109/tbcas.2017.2739724] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
This paper describes the design, fabrication, and testing of a microfluidic sensor for dielectric spectroscopy of human whole blood during coagulation. The sensor, termed ClotChip, employs a three-dimensional, parallel-plate, capacitive sensing structure with a floating electrode integrated into a microfluidic channel. Interfaced with an impedance analyzer, the ClotChip measures the complex relative dielectric permittivity, ϵr , of human whole blood in the frequency range of 40 Hz to 100 MHz. The temporal variation in the real part of the blood dielectric permittivity at 1 MHz features a time to reach a permittivity peak, , as well as a maximum change in permittivity after the peak, , as two distinct parameters of ClotChip readout. The ClotChip performance was benchmarked against rotational thromboelastometry (ROTEM) to evaluate the clinical utility of its readout parameters in capturing the clotting dynamics arising from coagulation factors and platelet activity. exhibited a very strong positive correlation ( r = 0.99, p < 0.0001) with the ROTEM clotting time parameter, whereas exhibited a strong positive correlation (r = 0.85, p < 0.001) with the ROTEM maximum clot firmness parameter. This paper demonstrates the ClotChip potential as a point-of-care platform to assess the complete hemostatic process using <10 μL of human whole blood.
Collapse
|
41
|
Fractional Calculus Based FDTD Modeling of Layered Biological Media Exposure to Wideband Electromagnetic Pulses. ELECTRONICS 2017. [DOI: 10.3390/electronics6040106] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
42
|
Roussakow SV. Clinical and economic evaluation of modulated electrohyperthermia concurrent to dose-dense temozolomide 21/28 days regimen in the treatment of recurrent glioblastoma: a retrospective analysis of a two-centre German cohort trial with systematic comparison and effect-to-treatment analysis. BMJ Open 2017; 7:e017387. [PMID: 29102988 PMCID: PMC5722101 DOI: 10.1136/bmjopen-2017-017387] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/15/2023] Open
Abstract
OBJECTIVE To assess the efficacy and cost-effectiveness of modulated electrohyperthermia (mEHT) concurrent to dose-dense temozolomide (ddTMZ) 21/28 days regimen versus ddTMZ 21/28 days alone in patients with recurrent glioblastoma (GBM). DESIGN A cohort of 54 patients with recurrent GBM treated with ddTMZ+mEHT in 2000-2005 was systematically retrospectively compared with five pooled ddTMZ 21/28 days cohorts (114 patients) enrolled in 2008-2013. RESULTS The ddTMZ+mEHT cohort had a not significantly improved mean survival time (mST) versus the comparator (p=0.531) after a significantly less mean number of cycles (1.56 vs 3.98, p<0.001). Effect-to-treatment analysis (ETA) suggests that mEHT significantly enhances the efficacy of the ddTMZ 21/28 days regimen (p=0.011), with significantly less toxicity (no grade III-IV toxicity vs 45%-92%, p<0.0001). An estimated maximal attainable median survival time is 10.10 months (9.10-11.10). Cost-effectiveness analysis suggests that, unlike ddTMZ 21/28 days alone, ddTMZ+mEHT is cost-effective versus the applicable cost-effectiveness thresholds €US$25 000-50 000/quality-adjusted life year (QALY). Budget impact analysis suggests a significant saving of €8 577 947/$11 201 761 with 29.1-38.5 QALY gained per 1000 patients per year. Cost-benefit analysis suggests that mEHT is profitable and will generate revenues between €3 124 574 and $6 458 400, with a total economic effect (saving+revenues) of €5 700 034 to $8 237 432 per mEHT device over an 8-year period. CONCLUSIONS Our ETA suggests that mEHT significantly improves survival of patients receiving the ddTMZ 21/28 days regimen. Economic evaluation suggests that ddTMZ+mEHT is cost-effective, budget-saving and profitable. After confirmation of the results, mEHT could be recommended for the treatment of recurrent GBM as a cost-effective enhancer of ddTMZ regimens, and, probably, of the regular 5/28 days regimen. mEHT is applicable also as a single treatment if chemotherapy is impossible, and as a salvage treatment after the failure of chemotherapy.
Collapse
|
43
|
Picosecond orientational dynamics of water in living cells. Nat Commun 2017; 8:904. [PMID: 29026086 PMCID: PMC5714959 DOI: 10.1038/s41467-017-00858-0] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Accepted: 08/01/2017] [Indexed: 11/18/2022] Open
Abstract
Cells are extremely crowded, and a central question in biology is how this affects the intracellular water. Here, we use ultrafast vibrational spectroscopy and dielectric-relaxation spectroscopy to observe the random orientational motion of water molecules inside living cells of three prototypical organisms: Escherichia coli, Saccharomyces cerevisiae (yeast), and spores of Bacillus subtilis. In all three organisms, most of the intracellular water exhibits the same random orientational motion as neat water (characteristic time constants ~9 and ~2 ps for the first-order and second-order orientational correlation functions), whereas a smaller fraction exhibits slower orientational dynamics. The fraction of slow intracellular water varies between organisms, ranging from ~20% in E. coli to ~45% in B. subtilis spores. Comparison with the water dynamics observed in solutions mimicking the chemical composition of (parts of) the cytosol shows that the slow water is bound mostly to proteins, and to a lesser extent to other biomolecules and ions. The cytoplasm’s crowdedness leads one to expect that cell water is different from bulk water. By measuring the rotational motion of water molecules in living cells, Tros et al. find that apart from a small fraction of water solvating biomolecules, cell water has the same dynamics as bulk water.
Collapse
|
44
|
Maji D, Suster MA, Kucukal E, Gurkan UA, Stavrou EX, Mohseni P. A PMMA microfluidic dielectric sensor for blood coagulation monitoring at the point-of-care. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:291-294. [PMID: 28268334 DOI: 10.1109/embc.2016.7590697] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper describes the design and construct of a fully biocompatible, microfluidic, dielectric sensor targeted at monitoring human whole blood coagulation at the point-of-care (POC). The sensor assembly procedure involves using sputtered electrodes in a microfluidic channel with a physiologically relevant height of 50μm to create a three-dimensional (3D), parallel-plate, capacitive sensing area. The sensor is constructed with biocompatible materials of polymethyl methacrylate (PMMA) for the substrate and titanium nitride (TiN) for the sensing and floating electrodes. The real part of the complex relative dielectric permittivity of human whole blood is measured from 10kHz to 100MHz using an impedance analyzer and under static conditions. The temporal variation in dielectric permittivity at 1MHz for human whole blood undergoing coagulation shows a peak in permittivity at 5 minutes, which closely matches our previously established results. This sensor can pave the way for monitoring blood coagulation under physiologically relevant shear flow rates in the future.
Collapse
|
45
|
Souli MP, Klonos P, Fragopoulou AF, Mavragani IV, Pateras IS, Kostomitsopoulos N, Margaritis LH, Zoumpoulis P, Kaklamanis L, Kletsas D, Gorgoulis VG, Kyritsis A, Pissis P, Georgakilas AG. Applying Broadband Dielectric Spectroscopy (BDS) for the Biophysical Characterization of Mammalian Tissues under a Variety of Cellular Stresses. Int J Mol Sci 2017; 18:ijms18040838. [PMID: 28420124 PMCID: PMC5412422 DOI: 10.3390/ijms18040838] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Revised: 04/10/2017] [Accepted: 04/12/2017] [Indexed: 11/16/2022] Open
Abstract
The dielectric properties of biological tissues can contribute non-invasively to a better characterization and understanding of the structural properties and physiology of living organisms. The question we asked, is whether these induced changes are effected by an endogenous or exogenous cellular stress, and can they be detected non-invasively in the form of a dielectric response, e.g., an AC conductivity switch in the broadband frequency spectrum. This study constitutes the first methodological approach for the detection of environmental stress-induced damage in mammalian tissues by the means of broadband dielectric spectroscopy (BDS) at the frequencies of 1-10⁶ Hz. Firstly, we used non-ionizing (NIR) and ionizing radiation (IR) as a typical environmental stress. Specifically, rats were exposed to either digital enhanced cordless telecommunication (DECT) radio frequency electromagnetic radiation or to γ-radiation, respectively. The other type of stress, characterized usually by high genomic instability, was the pathophysiological state of human cancer (lung and prostate). Analyzing the results of isothermal dielectric measurements provided information on the tissues' water fraction. In most cases, our methodology proved sufficient in detecting structural changes, especially in the case of IR and malignancy. Useful specific dielectric response patterns are detected and correlated with each type of stress. Our results point towards the development of a dielectric-based methodology for better understanding and, in a relatively invasive way, the biological and structural changes effected by radiation and developing lung or prostate cancer often associated with genomic instability.
Collapse
Affiliation(s)
- Maria P Souli
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| | - Panagiotis Klonos
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| | - Adamantia F Fragopoulou
- Department of Cell Biology and Biophysics, Faculty of Biology, University of Athens, 15701 Athens, Greece.
| | - Ifigeneia V Mavragani
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| | - Ioannis S Pateras
- Molecular Carcinogenesis Group, Department of Histology and Embryology, School of Medicine, University of Athens, 11527 Athens, Greece.
| | - Nikolaos Kostomitsopoulos
- Laboratory Animal Facilities, Center of Clinical, Experimental Surgery and Translational Research, Biomedical Research Foundation, Academy of Athens, 4 Soranou Efesiou Street, 11527 Athens, Greece.
| | - Lukas H Margaritis
- Department of Cell Biology and Biophysics, Faculty of Biology, University of Athens, 15701 Athens, Greece.
| | - Pavlos Zoumpoulis
- Diagnostic Echotomography Medical S.A., 317C Kifissias Avenue, 145 61 Kifissia, Greece.
| | - Loukas Kaklamanis
- Department of Pathology, Onassis Cardiac Surgery Center, 356 Sygrou Avenue, 17674 Kallithea, Greece.
| | - Dimitris Kletsas
- Laboratory of Cell Proliferation and Ageing, Institute of Biosciences and Applications, National Centre for Scientific Research "Demokritos", 60037 Athens, Greece.
| | - Vassilis G Gorgoulis
- Molecular Carcinogenesis Group, Department of Histology and Embryology, School of Medicine, University of Athens, 11527 Athens, Greece.
| | - Apostolos Kyritsis
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| | - Polycarpos Pissis
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| | - Alexandros G Georgakilas
- Physics Department, School of Applied Mathematical and Physical Sciences, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece.
| |
Collapse
|
46
|
Maji D, Suster MA, Stavrou E, Gurkan UA, Mohseni P. Monitoring time course of human whole blood coagulation using a microfluidic dielectric sensor with a 3D capacitive structure. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:5904-7. [PMID: 26737635 DOI: 10.1109/embc.2015.7319735] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
This paper reports on the design, fabrication, and testing of a microfluidic sensor for dielectric spectroscopy (DS) of human whole blood during coagulation. The sensor employs a three-dimensional (3D), parallel-plate, capacitive sensing structure with a floating electrode integrated into a microfluidic channel. Using an impedance analyzer and after a 5-point calibration, the sensor is shown to measure the real part of complex relative dielectric permittivity of human whole blood in a frequency range of 10kHz to 100MHz. The temporal variation of dielectric permittivity at 1MHz for human whole blood from three different healthy donors shows a peak in permittivity at ~ 4 to 5 minutes, which also corresponds to the onset of CaCl2-initiated coagulation of the blood sample verified visually.
Collapse
|
47
|
Agranovich D, Renhart I, Ben Ishai P, Katz G, Bezman D, Feldman Y. A microwave sensor for the characterization of bovine milk. Food Control 2016. [DOI: 10.1016/j.foodcont.2015.11.032] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
48
|
Ivanov IT, Paarvanova B. Dielectric relaxations on erythrocyte membrane as revealed by spectrin denaturation. Bioelectrochemistry 2016; 110:59-68. [PMID: 27071054 DOI: 10.1016/j.bioelechem.2016.03.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Revised: 03/25/2016] [Accepted: 03/26/2016] [Indexed: 11/30/2022]
Abstract
We studied the effect of spectrin denaturation at 49.5°C (TA) on the dielectric relaxations and related changes in the complex impedance, Z*, complex capacitance, C*, and dielectric loss curve of suspensions containing human erythrocytes, erythrocyte ghost membranes (EMs) and Triton-X-100 residues of EMs. The loss curve prior to, minus the loss curve after TA, resulted in a bell-shaped peak at 1.5MHz. The changes in the real and imaginary components of Z* and C* at TA, i.e., ΔZre, ΔZim, ΔCre and ΔCim, calculated in the same way, strongly varied with frequency. Between 1.0 and 12MHz the -ΔZim vs ΔZre, and ΔCim vs ΔCre plots depicted semicircles with critical frequencies, fcr, at 2.5MHz expressing recently reported relaxation of spectrin dipoles. Between 0.02 and 1.0MHz the -ΔZim vs ΔZre plot exhibited another relaxation whose fcr mirrored that of beta relaxation. This relaxation was absent on Triton-X-shells, while on erythrocytes and EMs it was inhibited by selective dissociation of either attachment sites between spectrin and bilayer. Considering above findings and inaccessibility of cytosole to outside field at such frequencies, the latter relaxation was assumed originating from a piezoelectric effect on the highly deformable spectrin filaments.
Collapse
Affiliation(s)
- I T Ivanov
- Dept. of Physics, Biophysics, Reontgenology and Radiology, Medical Faculty, Thracian University, Stara Zagora 6000, Bulgaria.
| | - B Paarvanova
- Dept. of Physics, Biophysics, Reontgenology and Radiology, Medical Faculty, Thracian University, Stara Zagora 6000, Bulgaria
| |
Collapse
|
49
|
Rinne KF, Schulz JCF, Netz RR. Impact of secondary structure and hydration water on the dielectric spectrum of poly-alanine and possible relation to the debate on slaved versus slaving water. J Chem Phys 2016; 142:215104. [PMID: 26049528 DOI: 10.1063/1.4921777] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Using extensive molecular dynamics simulations of a single eight-residue alanine polypeptide in explicit water, we investigate the influence of α-helix formation on the dielectric spectrum. For this, we project long equilibrium trajectories into folded and unfolded states and thereby obtain dielectric spectra representative for disordered as well α-helical conformations without the need to change any other system parameter such as pH or temperature. The absorption spectrum in the α-helical state exhibits a feature in the sub-GHz range that is significantly stronger than in the unfolded state. As we show by an additional decomposition into peptide and water contributions, this slow dielectric mode, the relaxation time of which matches the independently determined peptide rotational relaxation time, is mostly caused by peptide polarization correlations, but also contains considerable contributions from peptide-water correlations. In contrast, the peptide spectral contribution shows no features in the GHz range where bulk water absorbs, not even in the peptide-water correlation part, we conclude that hydration water around Ala8 is more influenced by peptide polarization relaxation effects than the other way around. A further decomposition into water-self and water-collective polarization correlations shows that the dielectric response of hydration water is, in contrast to electrolyte solutions, retarded and that this retardation is mostly due to collective effects, the self relaxation of hydration water molecules is only slightly slowed down compared to bulk water. We find the dynamic peptide-water polarization cross correlations to be rather long-ranged and to extend more than one nanometer away from the peptide-water interface into the water hydration shell, in qualitative agreement with previous simulation studies and recent THz absorption experiments.
Collapse
Affiliation(s)
- Klaus F Rinne
- Fachbereich Physik, Freie Universität Berlin, 14195 Berlin, Germany
| | | | - Roland R Netz
- Fachbereich Physik, Freie Universität Berlin, 14195 Berlin, Germany
| |
Collapse
|
50
|
Yang J, Selvaganapathy PR, Gould TJ, Dwivedi DJ, Liu D, Fox-Robichaud AE, Liaw PC. A microfluidic device for rapid quantification of cell-free DNA in patients with severe sepsis. LAB ON A CHIP 2015; 15:3925-3933. [PMID: 26288129 DOI: 10.1039/c5lc00681c] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A rapid and accurate method to identify severe sepsis patients at high risk of death is critically needed for clinical practice. In a recent study, the concentration of cell-free DNA (cfDNA) in blood was found to be a prognostic indicator for ICU mortality in patients with severe sepsis. However, current DNA quantification techniques are time-consuming and involve extensive sample preparation. In this paper, we demonstrate a low-cost microfluidic device capable of rapid quantification of cfDNA in a small droplet (<10 μl) of blood plasma and whole blood in 5 min using only electrical power. The cfDNA in samples is selectively labeled by PicoGreen and is extracted and concentrated by electrophoresis into a gel by application of a DC potential of 9 V. This device has potential as a prognostic tool for early and rapid assessment of septic patients.
Collapse
Affiliation(s)
- Jun Yang
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
| | | | | | | | | | | | | |
Collapse
|