1
|
Xu X, Zuo Y, Chen S, Hatami A, Gu H. Advancements in Brain Research: The In Vivo/In Vitro Electrochemical Detection of Neurochemicals. BIOSENSORS 2024; 14:125. [PMID: 38534232 DOI: 10.3390/bios14030125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/12/2024] [Accepted: 02/20/2024] [Indexed: 03/28/2024]
Abstract
Neurochemicals, crucial for nervous system function, influence vital bodily processes and their fluctuations are linked to neurodegenerative diseases and mental health conditions. Monitoring these compounds is pivotal, yet the intricate nature of the central nervous system poses challenges. Researchers have devised methods, notably electrochemical sensing with micro-nanoscale electrodes, offering high-resolution monitoring despite low concentrations and rapid changes. Implantable sensors enable precise detection in brain tissues with minimal damage, while microdialysis-coupled platforms allow in vivo sampling and subsequent in vitro analysis, addressing the selectivity issues seen in other methods. While lacking temporal resolution, techniques like HPLC and CE complement electrochemical sensing's selectivity, particularly for structurally similar neurochemicals. This review covers essential neurochemicals and explores miniaturized electrochemical sensors for brain analysis, emphasizing microdialysis integration. It discusses the pros and cons of these techniques, forecasting electrochemical sensing's future in neuroscience research. Overall, this comprehensive review outlines the evolution, strengths, and potential applications of electrochemical sensing in the study of neurochemicals, offering insights into future advancements in the field.
Collapse
Affiliation(s)
- Xiaoxuan Xu
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Yimei Zuo
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Shu Chen
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
| | - Amir Hatami
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Prof. Sobouti Boulevard, P.O. Box 45195-1159, Zanjan 45137-66731, Iran
- Department of Chemistry and Molecular Biology, University of Gothenburg, 405 30 Gothenburg, Sweden
| | - Hui Gu
- Key Laboratory of Theoretical Organic Chemistry and Functional Molecule of Ministry of Education, School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201, China
- Department of Chemistry and Molecular Biology, University of Gothenburg, 405 30 Gothenburg, Sweden
| |
Collapse
|
2
|
Tůma P. Steady state microdialysis of microliter volumes of body fluids for monitoring of amino acids by capillary electrophoresis with contactless conductivity detection. Anal Chim Acta 2024; 1287:342113. [PMID: 38182349 DOI: 10.1016/j.aca.2023.342113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/03/2023] [Accepted: 12/04/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND The availability of dialysis membranes in the form of hollow fibres with diameters compatible with the fused silica capillaries used in capillary electrophoresis is very limited. However, haemodialysis bicarbonate cartridges commonly used in human medicine containing polysulfone hollow fibres are available on the market and are used for the fabrication of coaxial microdialysis probes. The miniature probe design ensures that steady-state conditions are achieved during microdialysis of minimal volumes of body fluids. RESULTS A coaxial microdialysis probe with a length of 5 cm and an inner diameter of 200 μm is used for microdialysis of 10 μL of body fluid collected into a sampling fused silica capillary with an inner diameter 430 μm. Microdialysis is performed into 0.01 M HCl as a perfusate at stopped flow and 2 μL of the resulting microdialysate are subjected to analysis by capillary electrophoresis with contactless conductivity detection. Microdialysis pre-treatment is verified by analysis of 11 common amino acids at a 100 μM concentration level, resulting in recoveries of 98.3-102.5%. The electrophoretic separation of amino acids is performed in 8.5 M acetic acid at pH 1.37 as a background electrolyte with analysis time up to 4.5 min and LOD in the range of 0.12-0.28 μM. The reproducibility of the developed technique determined for the peak area ranges from 1.2 to 4.5%. Applicability is tested in the quantification of valine and leucine in plasma during fasting and subsequent reconvalescence. SIGNIFICANCE The fabrication of a coaxial microdialysis probe for the laboratory preparation of microliter volumes of various types of clinical samples is described, which is coupled off-line with capillary electrophoretic monitoring of amino acids in 2 μL volumes of microdialysate. The developed methodology is suitable for quantification of 20 amino acids in whole human blood, plasma, tears and has potential for analysis of dry blood spots captured on hollow fibre.
Collapse
Affiliation(s)
- Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague, 10, Czechia.
| |
Collapse
|
3
|
Tůma P. Progress in on-line, at-line, and in-line coupling of sample treatment with capillary and microchip electrophoresis over the past 10 years: A review. Anal Chim Acta 2023; 1261:341249. [PMID: 37147053 DOI: 10.1016/j.aca.2023.341249] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/07/2023]
Abstract
The review presents an evaluation of the development of on-line, at-line and in-line sample treatment coupled with capillary and microchip electrophoresis over the last 10 years. In the first part, it describes different types of flow-gating interfaces (FGI) such as cross-FGI, coaxial-FGI, sheet-flow-FGI, and air-assisted-FGI and their fabrication using molding into polydimethylsiloxane and commercially available fittings. The second part deals with the coupling of capillary and microchip electrophoresis with microdialysis, solid-phase, liquid-phase, and membrane based extraction techniques. It mainly focuses on modern techniques such as extraction across supported liquid membrane, electroextraction, single drop microextraction, head space microextraction, and microdialysis with high spatial and temporal resolution. Finally, the design of sequential electrophoretic analysers and fabrication of SPE microcartridges with monolithic and molecularly imprinted polymeric sorbents are discussed. Applications include the monitoring of metabolites, neurotransmitters, peptides and proteins in body fluids and tissues to study processes in living organisms, as well as the monitoring of nutrients, minerals and waste compounds in food, natural and wastewater.
Collapse
Affiliation(s)
- Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic.
| |
Collapse
|
4
|
Gerson J, Erdal MK, McDonough MH, Ploense KL, Dauphin-Ducharme P, Honeywell KM, Leung KK, Arroyo-Curras N, Gibson JM, Emmons NA, Meiring W, Hespanha JP, Plaxco KW, Kippin TE. High-precision monitoring of and feedback control over drug concentrations in the brains of freely moving rats. SCIENCE ADVANCES 2023; 9:eadg3254. [PMID: 37196087 PMCID: PMC10191434 DOI: 10.1126/sciadv.adg3254] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 04/12/2023] [Indexed: 05/19/2023]
Abstract
Knowledge of drug concentrations in the brains of behaving subjects remains constrained on a number of dimensions, including poor temporal resolution and lack of real-time data. Here, however, we demonstrate the ability of electrochemical aptamer-based sensors to support seconds-resolved, real-time measurements of drug concentrations in the brains of freely moving rats. Specifically, using such sensors, we achieve <4 μM limits of detection and 10-s resolution in the measurement of procaine in the brains of freely moving rats, permitting the determination of the pharmacokinetics and concentration-behavior relations of the drug with high precision for individual subjects. In parallel, we have used closed-loop feedback-controlled drug delivery to hold intracranial procaine levels constant (±10%) for >1.5 hours. These results demonstrate the utility of such sensors in (i) the determination of the site-specific, seconds-resolved neuropharmacokinetics, (ii) enabling the study of individual subject neuropharmacokinetics and concentration-response relations, and (iii) performing high-precision control over intracranial drug levels.
Collapse
Affiliation(s)
- Julian Gerson
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
- Neuroscience Research Institute, University of California, Santa Barbara, CA 93106, USA
- Institute for Collaborative Biotechnologies, University of California, Santa Barbara, CA 93106, USA
| | - Murat Kaan Erdal
- Department of Electrical and Computer Engineering, University of California, Santa Barbara, CA 93106, USA
| | - Matthew H. McDonough
- Department of Statistics and Applied Probability, University of California, Santa Barbara, CA 93106, USA
| | - Kyle L. Ploense
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA 93106, USA
| | | | - Kevin M. Honeywell
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
| | - Kaylyn K. Leung
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA 93106, USA
| | - Netzahualcoyotl Arroyo-Curras
- Department of Pharmacology and Molecular Sciences, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
| | - Jenny M. Gibson
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
| | - Nicole A. Emmons
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
| | - Wendy Meiring
- Department of Statistics and Applied Probability, University of California, Santa Barbara, CA 93106, USA
| | - Joao P. Hespanha
- Department of Electrical and Computer Engineering, University of California, Santa Barbara, CA 93106, USA
| | - Kevin W. Plaxco
- Institute for Collaborative Biotechnologies, University of California, Santa Barbara, CA 93106, USA
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, CA 93106, USA
| | - Tod E. Kippin
- Department of Psychological and Brain Sciences, University of California, Santa Barbara, CA 93106, USA
- Neuroscience Research Institute, University of California, Santa Barbara, CA 93106, USA
- Department of Molecular Cellular and Developmental Biology, University of California, Santa Barbara, CA 93106, USA
| |
Collapse
|
5
|
A new electromembrane extraction probe for on-line connection with capillary electrophoresis for determination of substances in biological matrices. Talanta 2023; 254:124149. [PMID: 36463806 DOI: 10.1016/j.talanta.2022.124149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 11/20/2022] [Accepted: 11/26/2022] [Indexed: 11/30/2022]
Abstract
A miniature probe for electromembrane extraction is developed and constructed. The tubular probe with an internal volume of 1.1 μL is made of polypropylene hollow fiber with a supported liquid membrane of 85% nitrophenyloctyl ether (NPOE) with 15% bis(2-ethylhexyl)phosphonic acid (DEHP). The probe is connected on-line to the electrophoresis with short separation capillary via an air assisted flow gating interface cast from poly (dimethylsiloxane). The compact instrument is computer controlled via LabView. The probe parameters are tested for extraction of creatinine and basic amino acids from artificial solution and human urine. The sensitivity of the electrophoretic determination after 300 s extraction at 150 V compared to the sensitivity without extraction is 4.9-fold and 2.6-fold higher for creatinine and arginine, respectively. The RSDs for peak area measured from 5 repeated extractions of 50 μM solutions are 7.5%, 7.2%, 8.6% and 9.2% for Crea, Lys, Arg and His, respectively. The probe can be used for all-day measurements. The preparation of the probe is simple and requires no special tool.
Collapse
|
6
|
Gonzalez Quevedo P, Rigby EL, Kearney S, Saylor RA. Optimized derivatization of primary amines with the fluorogenic reagent naphthalene-2,3-dicarboxaldehyde toward reproducible quantitative analysis in biological systems. Anal Bioanal Chem 2023:10.1007/s00216-022-04508-3. [PMID: 36609859 DOI: 10.1007/s00216-022-04508-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 12/19/2022] [Accepted: 12/22/2022] [Indexed: 01/09/2023]
Abstract
Primary amines are the target of many bioanalytical analyses, as they are ubiquitous in biological systems and responsible for numerous important processes including neurotransmission and cell signaling. Primary amines can be sensitively detected via fluorescence after their reaction with the fluorogenic reagent naphthalene-2,3-dicarboxaldehyde (NDA) in the presence of cyanide through the formation of fluorescent N-substituted 1-cyanobenz[f]isoindole (CBI) derivatives. While fluorogenic reagents such as NDA can be advantageous for sensitive detection, improvements in both long-term stability and speed of reaction are necessary to enable practical and reproducible quantitative analysis. In this work, various CBI-amines were interrogated for their fluorescence characteristics over time under previously reported conditions (75:25 aqueous buffer:acetonitrile). An amine-specific decline in fluorescence and delay to reach maximum fluorescence were observed. Based on structural characteristics, we hypothesized that these effects were due to the solvents employed enabling analyte intermolecular interactions that resulted in fluorescence quenching over time. To mitigate fluorescence-quenching intermolecular interactions, we developed two strategies to improve the fluorescence of the CBI-product over long time periods: (1) the addition of the complexation reagent β-cyclodextrin to the reaction matrix and (2) the substitution of acetonitrile with dimethyl sulfoxide. Both strategies improved fluorescence stability over time, and the incorporation of dimethyl sulfoxide also enabled more rapid attainment of maximum fluorescence and a higher absolute fluorescence when compared to initial conditions. When employed in combination, these two approaches further improve fluorescence stability over time for the most hydrophobic analytes. In the future, these strategies can be employed for the practical and reproducible quantitative analysis of primary amines in biological systems, including those related to neurological disorders and disease states.
Collapse
Affiliation(s)
- Paola Gonzalez Quevedo
- Department of Chemistry and Biochemistry, Oberlin College, 119 Woodland St, Oberlin, OH, USA
| | - Elizabeth L Rigby
- Department of Chemistry and Biochemistry, Oberlin College, 119 Woodland St, Oberlin, OH, USA
| | - Samuel Kearney
- Department of Chemistry and Biochemistry, Oberlin College, 119 Woodland St, Oberlin, OH, USA
| | - Rachel A Saylor
- Department of Chemistry and Biochemistry, Oberlin College, 119 Woodland St, Oberlin, OH, USA.
| |
Collapse
|
7
|
Tůma P, Sommerová B, Koval D, Šiklová M, Koc M. Plasma levels of creatine, 2-aminobutyric acid, acetyl-carnitine and amino acids during fasting measured by counter-current electrophoresis in PAMAPTAC capillary. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
8
|
Fejfarová V, Jarošíková R, Polák J, Sommerová B, Husáková J, Wosková V, Dubský M, Tůma P. Microdialysis as a tool for antibiotic assessment in patients with diabetic foot: a review. Front Endocrinol (Lausanne) 2023; 14:1141086. [PMID: 37139338 PMCID: PMC10150051 DOI: 10.3389/fendo.2023.1141086] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 03/17/2023] [Indexed: 05/05/2023] Open
Abstract
Diabetic foot is a serious late complication frequently caused by infection and ischaemia. Both require prompt and aggressive treatment to avoid lower limb amputation. The effectiveness of peripheral arterial disease therapy can be easily verified using triplex ultrasound, ankle-brachial/toe-brachial index examination, or transcutaneous oxygen pressure. However, the success of infection treatment is difficult to establish in patients with diabetic foot. Intravenous systemic antibiotics are recommended for the treatment of infectious complications in patients with moderate or serious stages of infection. Antibiotic therapy should be initiated promptly and aggressively to achieve sufficient serum and peripheral antibiotic concentrations. Antibiotic serum levels are easily evaluated by pharmacokinetic assessment. However, antibiotic concentrations in peripheral tissues, especially in diabetic foot, are not routinely detectable. This review describes microdialysis techniques that have shown promise in determining antibiotic levels in the surroundings of diabetic foot lesions.
Collapse
Affiliation(s)
- Vladimíra Fejfarová
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czechia
- Second Faculty of Medicine, Charles University, Prague, Czechia
- *Correspondence: Vladimíra Fejfarová,
| | - Radka Jarošíková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czechia
- Second Faculty of Medicine, Charles University, Prague, Czechia
| | - Jan Polák
- Department of Pathophysiology, Third Faculty of Medicine, Charles University, Prague, Czechia
| | - Blanka Sommerová
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague, Czechia
| | - Jitka Husáková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czechia
| | - Veronika Wosková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czechia
| | - Michal Dubský
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czechia
| | - Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague, Czechia
| |
Collapse
|
9
|
Tůma P. Monitoring of biologically active substances in clinical samples by capillary and microchip electrophoresis with contactless conductivity detection: A review. Anal Chim Acta 2022; 1225:340161. [DOI: 10.1016/j.aca.2022.340161] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 07/08/2022] [Accepted: 07/08/2022] [Indexed: 12/11/2022]
|
10
|
Tůma P, Jaček M, Sommerová B, Dlouhý P, Jarošíková R, Husáková J, Wosková V, Fejfarová V. Monitoring of amoxicilline and ceftazidime in the microdialysate of diabetic foot and serum by capillary electrophoresis with contactless conductivity detection. Electrophoresis 2022; 43:1129-1139. [PMID: 35072285 DOI: 10.1002/elps.202100366] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 11/11/2022]
Abstract
Determination of the broad-spectrum antibiotics amoxicilline (AMX) and ceftazidime (CTZ) in blood serum and microdialysates of the subcutaneous tissue of the lower limbs is performed using CE with contactless conductivity detection (C4 D). Baseline separation of AMX is achieved in 0.5 M acetic acid as the background electrolyte and separation of CTZ in 3.2 M acetic acid with addition of 13% v/v methanol. The CE-C4 D determination is performed in a 25 µm capillary with suppression of the EOF using INST-coating on an effective length of 18 cm and the attained migration time is 4.2 min for AMX and 4.4 min for CTZ. The analysis was performed using 20 µl of serum and 15 µl of microdialysate, treated by the addition of acetonitrile in a ratio of 1/3 v/v and the sample is injected into the capillary using the large volume sample stacking technique. The LOQ attained in the microdialysate is 148 ng/ml for AMX and 339 ng/ml for CTZ, and in serum 143 ng/ml for AMX and 318 ng/ml for CTZ. The CE-C4 D method is employed for monitoring the passage of AMX and CTZ from the blood circulatory system into the subcutaneous tissue at the sites of diabetic ulceration in patients suffering from diabetic foot syndrome and also for measuring the pharmacokinetics following intravenous application of bolus antibiotic doses.
Collapse
Affiliation(s)
- Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Martin Jaček
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Blanka Sommerová
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Pavel Dlouhý
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague 10, Czech Republic
| | - Radka Jarošíková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Jitka Husáková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Veronika Wosková
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| | - Vladimíra Fejfarová
- Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague 4, Czech Republic
| |
Collapse
|
11
|
Liu R, Feng ZY, Li D, Jin B, Yan Lan, Meng LY. Recent trends in carbon-based microelectrodes as electrochemical sensors for neurotransmitter detection: A review. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116541] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
12
|
In vivo real-time monitoring of anti-factor Xa level using a microdialysis-coupled microfluidic device. TALANTA OPEN 2021. [DOI: 10.1016/j.talo.2021.100059] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
13
|
Joseph A, Rajendran A, Karthikeyan A, Nair BG. Implantable Microfluidic Device: An Epoch of Technology. Curr Pharm Des 2021; 28:679-689. [PMID: 34525928 DOI: 10.2174/1381612827666210825114403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Accepted: 05/28/2021] [Indexed: 11/22/2022]
Abstract
Implantable microfluidic devices are milestones in developing devices that can either measure parameters like ocular pressure and blood glucose level or deliver various components for therapeutic needs or behavioral modification. Researchers are currently focusing on the miniaturization of almost all its tools for a better healthcare platform. Implantable microfluidic devices are a combination of various systems including, but not limited to, microfluidic platforms, reservoirs, sensors, and actuators, implanted inside the body of a living entity (in vivo) with the purpose of directly or indirectly helping the entity. It is a multidisciplinary approach with immense potential in the area of the biomedical field. Significant resources are utilizing on for the research and development of these devices for various applications. The induction of an implantable microfluidic device into an animal would enable us to measure the responses without any repeated invasive procedures. Such data would help in the development of a better drug delivery profile. Implantable microfluidic devices with reservoirs deliver specific chemical or biological products to treat situations like cancers and diabetes. They can also deliver fluorophores for specific imaging inside the body. Implantable microfluidic devices help provide a microenvironment for various cell differentiation procedure. These devices know no boundaries, and this article reviews these devices based on their design and applications.
Collapse
Affiliation(s)
- Abey Joseph
- School of Biotechnology, National Institute of Technology, Calicut, Kerala, India; b Institute of Advanced Energy, Kyoto University; c RIKEN, Nanomedical Engineering Laboratory. Japan
| | - Arivazhagan Rajendran
- School of Biotechnology, National Institute of Technology, Calicut, Kerala, India; b Institute of Advanced Energy, Kyoto University; c RIKEN, Nanomedical Engineering Laboratory. Japan
| | - Akash Karthikeyan
- School of Biotechnology, National Institute of Technology, Calicut, Kerala, India; b Institute of Advanced Energy, Kyoto University; c RIKEN, Nanomedical Engineering Laboratory. Japan
| | - Baiju G Nair
- School of Biotechnology, National Institute of Technology, Calicut, Kerala, India; b Institute of Advanced Energy, Kyoto University; c RIKEN, Nanomedical Engineering Laboratory. Japan
| |
Collapse
|
14
|
Capillary Electrophoresis as a Monitoring Tool for Flow Composition Determination. Molecules 2021; 26:molecules26164918. [PMID: 34443507 PMCID: PMC8398840 DOI: 10.3390/molecules26164918] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 12/03/2022] Open
Abstract
Flow analysis is the science of performing quantitative analytical chemistry in flowing streams. Because of its efficiency and speed of analysis, capillary electrophoresis (CE) is a prospective method for the monitoring of a flow composition withdrawn from various processes (e.g., occurring in bioreactors, fermentations, enzymatic assays, and microdialysis samples). However, interfacing CE to a various flow of interest requires further study. In this paper, several ingenious approaches on interfacing flow from various chemical or bioprocesses to a capillary electrophoresis instrument are reviewed. Most of these interfaces can be described as computer-controlled autosamplers. Even though most of the described interfaces waste too many samples, many interesting and important applications of the devices are reported. However, the lack of commercially available devices prevents the wide application of CE for flow analysis. On the contrary, this fact opens up a potential avenue for future research in the field of flow sampling by CE.
Collapse
|
15
|
Lu Z, Xu S, Wang H, He E, Liu J, Dai Y, Xie J, Song Y, Wang Y, Wang Y, Qu L, Cai X. PtNPt/MWCNT-PEDOT:PSS-Modified Microelectrode Arrays for the Synchronous Dopamine and Neural Spike Detection in Rat Models of Sleep Deprivation. ACS APPLIED BIO MATERIALS 2021; 4:4872-4884. [PMID: 35007036 DOI: 10.1021/acsabm.1c00172] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In this study, a biosensor assembly based on microelectrode arrays (MEAs) modified with PtNPt/MWCNT-PEDOT:PSS nanocomposites is presented to synchronously detect the dopamine (DA) and electrophysiological activities in rat brains. Different morphological and electrochemical characterizations were conducted to show the excellent mechanical and electrical properties of the as-prepared probes. The developed biosensors realized the sensitive and selective detection of DA with the existence of significant interferences such as uric acid (UA), ascorbic acid (AA), glutamate (Glu), and 3,4-dihydroxyphenylacetic acid (DOPAC). Calibration curve for the DA response was linear with the concentration from 0.05 μM to 79 μM (R = 0.999), with a sensitivity of 30.561 pA/μM and detection limit as low as 50 nM. Finally, the proposed microelectrode was applied to be implanted into the cortex and caudate putamen (CPU) of rats, which was demonstrated to stably measure the synchronous neurochemical and neurophysiological changes caused by 72 h sleep deprivation. The in vivo measuring results showed that the sleep deprivation increased the DA release and neural spike activity in both cortex and CPU. The local field potential (LFP) power in the delta and theta band was significantly increased as well. These changes in brain may reflect the brain's adaptive reaction toward the side effects induced by sleep deprivation and may partially explain the mechanism of forced wakefulness in the presence of accumulated sleep pressure.
Collapse
Affiliation(s)
- Zeying Lu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Shengwei Xu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Hao Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Enhui He
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Juntao Liu
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Yuchuan Dai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Jingyu Xie
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Yilin Song
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Yun Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Yiding Wang
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| | - Lina Qu
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing 100094, China
| | - Xinxia Cai
- State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100120, China
- University of Chinese Academy of Sciences, Beijing 100042, China
| |
Collapse
|
16
|
Liu Y, Xia L, Dutta D. Reduction in sample injection bias using pressure gradients generated on chip. Electrophoresis 2021; 42:983-990. [PMID: 33569844 DOI: 10.1002/elps.202000299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/21/2021] [Accepted: 01/29/2021] [Indexed: 11/10/2022]
Abstract
Sample injection in microchip-based capillary zone electrophoresis (CZE) frequently rely on the use of electric fields which can introduce differences in the injected volume for the various analytes depending on their electrophoretic mobilities and molecular diffusivities. While such injection biases may be minimized by employing hydrodynamic flows during the injection process, this approach typically requires excellent dynamic control over the pressure gradients applied within a microfluidic network. The current article describes a microchip device that offers this needed control by generating pressure gradients on-chip via electrokinetic means to minimize the dead volume in the system. In order to realize the desired pressure-generation capability, an electric field was applied across two channel segments of different depths to produce a mismatch in the electroosmotic flow rate at their junction. The resulting pressure-driven flow was then utilized to introduce sample zones into a CZE channel with minimal injection bias. The reported injection strategy allowed the introduction of narrow sample plugs with spatial standard deviations down to about 45 μm. This injection technique was later integrated to a capillary zone electrophoresis process for analyzing amino acid samples yielding separation resolutions of about 4-6 for the analyte peaks in a 3 cm long analysis channel.
Collapse
Affiliation(s)
- Yukari Liu
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Ling Xia
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| | - Debashis Dutta
- Department of Chemistry, University of Wyoming, Laramie, WY, 82071, USA
| |
Collapse
|
17
|
Absolute quantitative analysis of endogenous neurotransmitters and amino acids by liquid chromatography-tandem mass spectrometry combined with multidimensional adsorption and collision energy defect. J Chromatogr A 2021; 1638:461867. [PMID: 33485029 DOI: 10.1016/j.chroma.2020.461867] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 12/25/2020] [Accepted: 12/28/2020] [Indexed: 01/06/2023]
Abstract
Considering that neurotransmitters (NTs) and amino acids (AAs) exert pivotal roles in various neurological diseases, global detection of these endogenous metabolites is of great significance for the treatment of nervous system diseases. Herein, a workflow that could cope with various challenges was proposed to establish an extendable all-in-one injection liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for analyzing these small molecular metabolites with high coverage. To obtain a qualified blank biological matrix for the preparation of standard curves and quality control samples, different absorption solvents, including activated carbon (AC), calcite (Cal) and montmorillonite (Mnt) were systematically evaluated for efficient absorption of endogenous substances with minimum residue. We also firstly proposed a "Collision Energy Defect (CED)" strategy to solve the huge difference of mass signal strength caused by different properties and concentrations of 11 NTs and 17 AAs. The quantitative results were validated by LC-MS/MS. Sensitivity, accuracy, and recovery meeting generally accepted bioanalytic guidelines were observed in a concentration span of at least 100 to 500 times for each analyte. Then the temporal changes of intracerebral and peripheral NTs and AAs in ischemic stroke model and sham operated rats were successfully produced and compared using the described method. All these results suggested that the currently developed assay was powerful enough to simultaneously monitor a large panel of endogenous small molecule metabolites, which was expected to be widely used in the research of various diseases mediated by NTs and AAs.
Collapse
|
18
|
Opekar F, Tůma P. Dialysis of one sample drop on-line connected with electrophoresis in short capillary. Talanta 2020; 219:121252. [DOI: 10.1016/j.talanta.2020.121252] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/26/2020] [Accepted: 05/28/2020] [Indexed: 12/25/2022]
|
19
|
Schilly KM, Gunawardhana SM, Wijesinghe MB, Lunte SM. Biological applications of microchip electrophoresis with amperometric detection: in vivo monitoring and cell analysis. Anal Bioanal Chem 2020; 412:6101-6119. [PMID: 32347360 PMCID: PMC8130646 DOI: 10.1007/s00216-020-02647-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2020] [Revised: 03/29/2020] [Accepted: 04/06/2020] [Indexed: 01/01/2023]
Abstract
Microchip electrophoresis with amperometric detection (ME-EC) is a useful tool for the determination of redox active compounds in complex biological samples. In this review, a brief background on the principles of ME-EC is provided, including substrate types, electrode materials, and electrode configurations. Several different detection approaches are described, including dual-channel systems for dual-electrode detection and electrochemistry coupled with fluorescence and chemiluminescence. The application of ME-EC to the determination of catecholamines, adenosine and its metabolites, and reactive nitrogen and oxygen species in microdialysis samples and cell lysates is also detailed. Lastly, approaches for coupling of ME-EC with microdialysis sampling to create separation-based sensors that can be used for near real-time monitoring of drug metabolism and neurotransmitters in freely roaming animals are provided. Graphical abstract.
Collapse
Affiliation(s)
- Kelci M Schilly
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Shamal M Gunawardhana
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Manjula B Wijesinghe
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA
| | - Susan M Lunte
- Department of Chemistry, University of Kansas, 1567 Irving Hill Road, Lawrence, KS, 66045, USA.
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, 2030 Becker Drive, Lawrence, KS, 66047, USA.
- Department of Pharmaceutical Chemistry, University of Kansas, 2010 Becker Drive, Lawrence, KS, 66045, USA.
| |
Collapse
|
20
|
Caruso G, Musso N, Grasso M, Costantino A, Lazzarino G, Tascedda F, Gulisano M, Lunte SM, Caraci F. Microfluidics as a Novel Tool for Biological and Toxicological Assays in Drug Discovery Processes: Focus on Microchip Electrophoresis. MICROMACHINES 2020; 11:E593. [PMID: 32549277 PMCID: PMC7344675 DOI: 10.3390/mi11060593] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Revised: 06/04/2020] [Accepted: 06/10/2020] [Indexed: 02/07/2023]
Abstract
The last decades of biological, toxicological, and pharmacological research have deeply changed the way researchers select the most appropriate 'pre-clinical model'. The absence of relevant animal models for many human diseases, as well as the inaccurate prognosis coming from 'conventional' pre-clinical models, are among the major reasons of the failures observed in clinical trials. This evidence has pushed several research groups to move more often from a classic cellular or animal modeling approach to an alternative and broader vision that includes the involvement of microfluidic-based technologies. The use of microfluidic devices offers several benefits including fast analysis times, high sensitivity and reproducibility, the ability to quantitate multiple chemical species, and the simulation of cellular response mimicking the closest human in vivo milieu. Therefore, they represent a useful way to study drug-organ interactions and related safety and toxicity, and to model organ development and various pathologies 'in a dish'. The present review will address the applicability of microfluidic-based technologies in different systems (2D and 3D). We will focus our attention on applications of microchip electrophoresis (ME) to biological and toxicological studies as well as in drug discovery and development processes. These include high-throughput single-cell gene expression profiling, simultaneous determination of antioxidants and reactive oxygen and nitrogen species, DNA analysis, and sensitive determination of neurotransmitters in biological fluids. We will discuss new data obtained by ME coupled to laser-induced fluorescence (ME-LIF) and electrochemical detection (ME-EC) regarding the production and degradation of nitric oxide, a fundamental signaling molecule regulating virtually every critical cellular function. Finally, the integration of microfluidics with recent innovative technologies-such as organoids, organ-on-chip, and 3D printing-for the design of new in vitro experimental devices will be presented with a specific attention to drug development applications. This 'composite' review highlights the potential impact of 2D and 3D microfluidic systems as a fast, inexpensive, and highly sensitive tool for high-throughput drug screening and preclinical toxicological studies.
Collapse
Affiliation(s)
- Giuseppe Caruso
- Oasi Research Institute—IRCCS, 94018 Troina (EN), Italy; (M.G.); (F.C.)
| | - Nicolò Musso
- Department of Biomedical and Biotechnological Sciences (BIOMETEC), University of Catania, 95125 Catania, Italy; (N.M.); (G.L.)
| | - Margherita Grasso
- Oasi Research Institute—IRCCS, 94018 Troina (EN), Italy; (M.G.); (F.C.)
- Department of Drug Sciences, University of Catania, 95125 Catania, Italy; (A.C.); (M.G.)
| | - Angelita Costantino
- Department of Drug Sciences, University of Catania, 95125 Catania, Italy; (A.C.); (M.G.)
| | - Giuseppe Lazzarino
- Department of Biomedical and Biotechnological Sciences (BIOMETEC), University of Catania, 95125 Catania, Italy; (N.M.); (G.L.)
| | - Fabio Tascedda
- Department of Life Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy;
- Center for Neuroscience and Neurotechnology, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Massimo Gulisano
- Department of Drug Sciences, University of Catania, 95125 Catania, Italy; (A.C.); (M.G.)
- Molecular Preclinical and Translational Imaging Research Centre-IMPRonTE, University of Catania, 95125 Catania, Italy
- Interuniversity Consortium for Biotechnology, Area di Ricerca, Padriciano, 34149 Trieste, Italy
| | - Susan M. Lunte
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS 66047-1620, USA;
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS 66047-1620, USA
- Department of Chemistry, University of Kansas, Lawrence, KS 66047-1620, USA
| | - Filippo Caraci
- Oasi Research Institute—IRCCS, 94018 Troina (EN), Italy; (M.G.); (F.C.)
- Department of Drug Sciences, University of Catania, 95125 Catania, Italy; (A.C.); (M.G.)
| |
Collapse
|
21
|
Tůma P, Sommerová B, Daněček V. On-line coupling of capillary electrophoresis with microdialysis for determining saccharides in dairy products and honey. Food Chem 2020; 316:126362. [PMID: 32050115 DOI: 10.1016/j.foodchem.2020.126362] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 10/24/2019] [Accepted: 02/04/2020] [Indexed: 12/19/2022]
Abstract
Free sucrose, lactose, galactose, glucose and fructose were determined in yoghurts, milk and honey using on-line coupling of capillary electrophoresis with microdialysis. The dairy products were diluted 50-fold with 10 mmol/L NaOH and sampled using laboratory-made microdialysis probes. The microdialysate was brought to the entrance of the electrophoretic capillary and the coupling consisted in a polydimethylsiloxane (PDMS) cross connector working in the flow-gating interface regime. The electrophoretic analysis was performed in 50 mmol/L NaOH (pH 12.6) background electrolyte, where baseline separation of the five saccharides was achieved in 3.5 min. The LOQs varied in the range 2.3-7.3 mg/L, the number of separation plates varied between 176,000 plates/m for glucose to 326,000 plates/m for galactose and the relative standard deviation (RSD) for ten consecutive analyses of fruit yoghurt was 0.2% for the migration time and 4.4-7.6% for the peak area.
Collapse
Affiliation(s)
- Petr Tůma
- Charles University, Third Faculty of Medicine, Department of Hygiene, Ruská 87, 100 00 Prague 10, Czech Republic.
| | - Blanka Sommerová
- Charles University, Third Faculty of Medicine, Department of Hygiene, Ruská 87, 100 00 Prague 10, Czech Republic
| | - Václav Daněček
- Charles University, Third Faculty of Medicine, Department of Biophysics, Ruská 87, 100 00 Prague 10, Czech Republic
| |
Collapse
|
22
|
Identification of the Constituents of Percutaneous Absorption from Duhaldea nervosa Based on UHPLC-Q-Exactive Orbitrap MS and Microdialysis Technique. Int J Anal Chem 2019; 2019:8328942. [PMID: 31827518 PMCID: PMC6885172 DOI: 10.1155/2019/8328942] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2019] [Accepted: 10/19/2019] [Indexed: 11/24/2022] Open
Abstract
Duhaldea nervosa (D. nervosa) has been used for treatment of bone fracture by external use. Thus, the percutaneous absorption was crucial to the effect of D. nervosa, especially the constituents of percutaneous absorption. However, the constituents in vivo were never investigated to date. In this study, an efficient method was developed for the identification of constituents of percutaneous absorption using UHPLC-Q-Exactive Orbitrap MS and microdialysis technique. A total of 20 constituents including 15 chlorogenic acid analogues, 3 amino acids, and 2 organic acids were unambiguously or tentatively identified based on high-resolution mass data including MS and MS2, chromatography retention time, and bibliography data. To the best of our knowledge, this is the first study to report the constituents of percutaneous absorption from D. nervosa, which will be very helpful for understanding the bioactive compounds and quality control.
Collapse
|
23
|
Scida K, Plaxco KW, Jamieson BG. High frequency, real-time neurochemical and neuropharmacological measurements in situ in the living body. Transl Res 2019; 213:50-66. [PMID: 31361988 DOI: 10.1016/j.trsl.2019.07.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 05/20/2019] [Accepted: 07/11/2019] [Indexed: 12/18/2022]
Abstract
The beautiful and complex brain machinery is perfectly synchronized, and our bodies have evolved to protect it against a myriad of potential threats. Shielded physically by the skull and chemically by the blood brain barrier, the brain processes internal and external information so that we can efficiently relate to the world that surrounds us while simultaneously and unconsciously controlling our vital functions. When coupled with the brittle nature of its internal chemical and electric signals, the brain's "armor" render accessing it a challenging and delicate endeavor that has historically limited our understanding of its structural and neurochemical intricacies. In this review, we briefly summarize the advancements made over the past 10 years to decode the brain's neurochemistry and neuropharmacology in situ, at the site of interest in the brain, with special focus on what we consider game-changing emerging technologies (eg, genetically encoded indicators and electrochemical aptamer-based sensors) and the challenges these must overcome before chronic, in situ chemosensing measurements become routine.
Collapse
Affiliation(s)
- Karen Scida
- Diagnostic Biochips, Inc., Glen Burnie, Maryland
| | - Kevin W Plaxco
- Department of Chemistry and Biochemistry, University of California, Santa Barbara, California
| | | |
Collapse
|
24
|
Samper IC, Gowers SAN, Rogers ML, Murray DSRK, Jewell SL, Pahl C, Strong AJ, Boutelle MG. 3D printed microfluidic device for online detection of neurochemical changes with high temporal resolution in human brain microdialysate. LAB ON A CHIP 2019; 19:2038-2048. [PMID: 31094398 PMCID: PMC9209945 DOI: 10.1039/c9lc00044e] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
This paper presents the design, optimisation and fabrication of a mechanically robust 3D printed microfluidic device for the high time resolution online analysis of biomarkers in a microdialysate stream at microlitre per minute flow rates. The device consists of a microfluidic channel with secure low volume connections that easily integrates electrochemical biosensors for biomarkers such as glutamate, glucose and lactate. The optimisation process of the microfluidic channel fabrication, including for different types of 3D printer, is explained and the resulting improvement in sensor response time is quantified. The time resolution of the device is characterised by recording short lactate concentration pulses. The device is employed to record simultaneous glutamate, glucose and lactate concentration changes simulating the physiological response to spreading depolarisation events in cerebrospinal fluid dialysate. As a proof-of-concept study, the device is then used in the intensive care unit for online monitoring of a brain injury patient, demonstrating its capabilities for clinical monitoring.
Collapse
Affiliation(s)
| | | | | | | | - Sharon L Jewell
- Department of Basic and Clinical Neuroscience, King's College, London, UK
| | - Clemens Pahl
- Department of Basic and Clinical Neuroscience, King's College, London, UK
| | - Anthony J Strong
- Department of Basic and Clinical Neuroscience, King's College, London, UK
| | | |
Collapse
|
25
|
Chenab KK, Eivazzadeh-Keihan R, Maleki A, Pashazadeh-Panahi P, Hamblin MR, Mokhtarzadeh A. Biomedical applications of nanoflares: Targeted intracellular fluorescence probes. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2019; 17:342-358. [PMID: 30826476 PMCID: PMC6520197 DOI: 10.1016/j.nano.2019.02.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 01/08/2019] [Accepted: 02/11/2019] [Indexed: 12/16/2022]
Abstract
Nanoflares are intracellular probes consisting of oligonucleotides immobilized on various nanoparticles that can recognize intracellular nucleic acids or other analytes, thus releasing a fluorescent reporter dye. Single-stranded DNA (ssDNA) complementary to mRNA for a target gene is constructed containing a 3'-thiol for binding to gold nanoparticles. The ssDNA "recognition sequence" is prehybridized to a shorter DNA complement containing a fluorescent dye that is quenched. The functionalized gold nanoparticles are easily taken up into cells. When the ssDNA recognizes its complementary target, the fluorescent dye is released inside the cells. Different intracellular targets can be detected by nanoflares, such as mRNAs coding for genes over-expressed in cancer (epithelial-mesenchymal transition, oncogenes, thymidine kinase, telomerase, etc.), intracellular levels of ATP, pH values and inorganic ions can also be measured. Advantages include high transfection efficiency, enzymatic stability, good optical properties, biocompatibility, high selectivity and specificity. Multiplexed assays and FRET-based systems have been designed.
Collapse
Affiliation(s)
- Karim Khanmohammadi Chenab
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, Iran
| | - Reza Eivazzadeh-Keihan
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, Iran
| | - Ali Maleki
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran, Iran
| | - Paria Pashazadeh-Panahi
- Department of Biochemistry and Biophysics, Metabolic Disorders Research Center, Gorgan Faculty of Medicine, Golestan University of Medical Sciences, Gorgan, Golestan Province, Iran; Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Michael R Hamblin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA, USA; Department of Dermatology, Harvard Medical School, Boston, MA, USA; Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA, USA.
| | - Ahad Mokhtarzadeh
- Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Biotechnology, Higher Education Institute of Rab-Rashid, Tabriz, Iran.
| |
Collapse
|
26
|
Tůma P. The Control of Glucose and Lactate Levels in Nutrient Medium After Cell Incubation and in Microdialysates of Human Adipose Tissue by Capillary Electrophoresis with Contactless Conductivity Detection. Methods Mol Biol 2019; 1972:95-108. [PMID: 30847786 DOI: 10.1007/978-1-4939-9213-3_7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
Two methods of capillary electrophoresis with contactless conductivity detection have been developed for monitoring the levels of glucose and lactate in clinical samples. The separations are performed in uncoated fused silica capillaries with inner diameter 10 or 20 μm, total length 31.5 cm, length to detector 18 cm, using an Agilent electrophoretic instrument with an integrated contactless conductivity detector. Glucose is determined in optimized background electrolyte, 50 mM NaOH with pH 12.6 and 2-deoxyglucose is used as an internal standard; the determination of lactate is performed in 40 mM CHES/NaOH with pH 9.4 and lithium cations as an internal standard. Both substances are determined in minimal volumes of (1) nutrient media after cell incubation, and (2) microdialysates of human adipose tissue; after dilution and filtration as the only treatment of the sample. The migration time of glucose is 2.5 min and that of lactate is 1.5 min with detection limits at the micromolar concentration level. The developed techniques are suitable for sequential monitoring of glucose and lactate over time during metabolic experiments.
Collapse
Affiliation(s)
- Petr Tůma
- Department of Hygiene, Third Faculty of Medicine, Charles University, Prague, Czech Republic.
| |
Collapse
|
27
|
Tůma P, Sommerová B, Šiklová M. Monitoring of adipose tissue metabolism using microdialysis and capillary electrophoresis with contactless conductivity detection. Talanta 2019; 192:380-386. [DOI: 10.1016/j.talanta.2018.09.076] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 09/19/2018] [Accepted: 09/20/2018] [Indexed: 02/02/2023]
|
28
|
Opekar F, Tůma P. An air-assisted flow-gating interface for capillary electrophoresis. Electrophoresis 2018; 40:587-590. [DOI: 10.1002/elps.201800421] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/08/2018] [Accepted: 11/13/2018] [Indexed: 11/09/2022]
Affiliation(s)
- František Opekar
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague Czech Republic
| | - Petr Tůma
- Third Faculty of Medicine; Department of Hygiene; Charles University; Prague Czech Republic
| |
Collapse
|
29
|
Bongaerts J, De Bundel D, Mangelings D, Smolders I, Vander Heyden Y, Van Eeckhaut A. Sensitive targeted methods for brain metabolomic studies in microdialysis samples. J Pharm Biomed Anal 2018; 161:192-205. [DOI: 10.1016/j.jpba.2018.08.043] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 08/20/2018] [Accepted: 08/21/2018] [Indexed: 02/06/2023]
|
30
|
Phairatana T, Leong CL, Gowers SAN, Patel BA, Boutelle MG. Real-time detection of carboplatin using a microfluidic system. Analyst 2018; 141:6270-6277. [PMID: 27796386 PMCID: PMC5123639 DOI: 10.1039/c6an01446a] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A novel on-line microfluidic assay for the chemotherapy agent carboplatin will allow sensitive detection of the drug directly applied to the tumour as it emerges from the tumour into healthy tissue.
A microfluidic sensor system based on a carbon nanotube-epoxy composite electrode was fabricated to allow detection of the presence of the anti-cancer drug carboplatin in healthy tissue in real time during chemotherapy. Detection of carboplatin was carried out by observing the effects of the drug on the differential pulse voltammetry of free purine bases using a novel carbon nanotube-epoxy composite electrode. In free solution these electrodes performed better than glassy carbon electrodes for oxidation of the free purine bases AMP and GMP, and than DNA-modified carbon nanotube-epoxy composite sensors for detection of carboplatin. On-line carboplatin detection was performed using a computer-controlled microfluidic platform. The methodology for on-line carboplatin detection was optimised in terms of the analysis time and to allow repeated carboplatin measurement using the same electrode. Microdialysis sampling and our microfluidic platform were combined to give a proof-of-concept system for real-time carboplatin detection with a limit of detection of 0.014 μM carboplatin in the sampled media. This paper is dedicated to Craig Lunte's pioneering work in analysis and microdialysis.
Collapse
Affiliation(s)
- Tonghathai Phairatana
- Institute of Biomedical Engineering, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand. and Department of Bioengineering, Faculty of Engineering, Imperial College London, London, UK.
| | - Chi Leng Leong
- Department of Bioengineering, Faculty of Engineering, Imperial College London, London, UK.
| | - Sally A N Gowers
- Department of Bioengineering, Faculty of Engineering, Imperial College London, London, UK.
| | - Bhavik Anil Patel
- School of Pharmacy and Biomolecular Sciences, University of Brighton, East Sussex, UK
| | - Martyn G Boutelle
- Department of Bioengineering, Faculty of Engineering, Imperial College London, London, UK.
| |
Collapse
|
31
|
Tabani H, Nojavan S, Alexovič M, Sabo J. Recent developments in green membrane-based extraction techniques for pharmaceutical and biomedical analysis. J Pharm Biomed Anal 2018; 160:244-267. [DOI: 10.1016/j.jpba.2018.08.002] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 08/01/2018] [Accepted: 08/03/2018] [Indexed: 01/11/2023]
|
32
|
Ngernsutivorakul T, Steyer DJ, Valenta AC, Kennedy RT. In Vivo Chemical Monitoring at High Spatiotemporal Resolution Using Microfabricated Sampling Probes and Droplet-Based Microfluidics Coupled to Mass Spectrometry. Anal Chem 2018; 90:10943-10950. [PMID: 30107117 DOI: 10.1021/acs.analchem.8b02468] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
An essential approach for in vivo chemical monitoring is to use sampling probes coupled with analytical methods; however, this method traditionally has limited spatial and temporal resolution. To address this problem, we developed an analytical system that combines microfabricated push-pull sampling probes with droplet-based microfluidics. The microfabricated probe provides spatial resolution approximately 1000-fold better than that of common microdialysis probes. Microfabrication also facilitated integration of an extra channel into the probe for microinjection. We created microfluidic devices and interfaces that allowed manipulation of nanoliter droplet samples collected from the microfabricated probe at intervals of a few seconds. Use of droplet-based microfluidics prevented broadening of collected zones, yielding 6 s temporal resolution at 100 nL/min perfusion rates. Resulting droplets were analyzed by direct infusion nanoelectrospray ionization (nESI) mass spectrometry for simultaneous determination of glutamine, glutamate, γ-aminobutyric acid, and acetylcholine. Use of low infusion rates that enabled nESI (50 nL/min) was critical to allowing detection in the complex samples. Addition of 13C-labeled internal standards to the droplet samples was used for improved quantification. Utility of the overall system was demonstrated by monitoring dynamic chemical changes evoked by microinjection of high potassium concentrations into the brain of live rats. The results showed stimulated neurochemical release with rise times of 15 s. This work demonstrates the potential of coupling microfabricated sampling probes to droplet-based mass spectrometric assays for studying chemical dynamics in a complex microenvironment at high spatiotemporal resolution.
Collapse
Affiliation(s)
- Thitaphat Ngernsutivorakul
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Daniel J Steyer
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Alec C Valenta
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States
| | - Robert T Kennedy
- Department of Chemistry , University of Michigan , 930 N. University Avenue , Ann Arbor , Michigan 48109 , United States.,Department of Pharmacology , University of Michigan , 1150 W. Medical Center Drive , Ann Arbor , Michigan 48109 , United States
| |
Collapse
|
33
|
Gunawardhana SM, Lunte SM. Continuous monitoring of adenosine and its metabolites using microdialysis coupled to microchip electrophoresis with amperometric detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2018; 10:3737-3744. [PMID: 31579297 PMCID: PMC6774626 DOI: 10.1039/c8ay01041b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Rapid monitoring of concentration changes of neurotransmitters and energy metabolites is important for understanding the biochemistry of neurological disease as well as for developing therapeutic options. This paper describes the development of a separation-based sensor using microchip electrophoresis (ME) with electrochemical (EC) detection coupled to microdialysis (MD) sampling for continuous on-line monitoring of adenosine and its downstream metabolites. The device was fabricated completely in PDMS. End-channel electrochemical detection was accomplished using a carbon fiber working electrode embedded in the PDMS. The separation conditions for adenosine, inosine, hypoxanthine, and guanosine were investigated using a ME-EC chip with a 5-cm long separation channel. The best resolution was achieved using a background electrolyte consisting of 35 mM sodium borate at pH 10, 15% dimethyl sulfoxide (DMSO), and 2 mM sodium dodecyl sulphate (SDS), and a field strength of 222 V/cm. Under these conditions, all four purines were separated in less than 85 s. Using a working electrode detection potential of 1.4 vs Ag/AgCl, the limits of detection were 25, 33, 10, and 25 μM for adenosine, inosine, hypoxanthine, and guanosine, respectively. The ME-EC chip was then coupled to microdialysis sampling using a novel all-PDMS microdialysis-microchip interface that was reversibly sealed. This made alignment of the working electrode with the end of the separation channel much easier and more reproducible than could be obtained with previous MD-ME-EC systems. The integrated device was then used to monitor the enzymatic conversion of adenosine to inosine in vitro.
Collapse
Affiliation(s)
- Shamal M Gunawardhana
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
- Department of Chemistry, University of Kansas, Lawrence, KS, USA
| | - Susan M Lunte
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
- Department of Chemistry, University of Kansas, Lawrence, KS, USA
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| |
Collapse
|
34
|
Negou JT, Hu J, Li X, Easley CJ. Advancement of analytical modes in a multichannel, microfluidic droplet-based sample chopper employing phase-locked detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2018; 10:3436-3443. [PMID: 30505354 PMCID: PMC6258173 DOI: 10.1039/c8ay00947c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
In this work, we expand upon our recently developed droplet-based sample chopping concepts by introducing a multiplexed fluidic micro-chopper device (μChopper). Six aqueous input channels were integrated with a single oil input, and each of these seven channels was controlled by a pneumatic valve for automated sampling through software control. This improved design, while maintaining high precision in valve-based droplet generation at bandwidths of 0.03 to 0.05 Hz, enabled a variety of analytical modes to be employed on-chip compared to previous devices limited to sample/reference alternations. The device was analytically validated for real-time, continuous calibration with a single sample and five standards; multiplexed analysis during calibration using a mixed mode; and standard addition through spiking of six sample droplets with varying amounts of standard. Finally, the standard addition mode was applied to protein quantification in human serum samples using on-chip, homogeneous fluorescence immunoassays. Ultimately, with only ~1.2 μL of total analyzed solution volume- representing 100-fold and 75-fold reductions in reagent and serum volumes, respectively-we were able to generate full, six-point standard addition curves in only 1.5 min, and results correlated well with those from standard plate-reader equipment. This work thus exploited microfluidic valves for both their automation and droplet phase-locking capabilities, resulting in a micro-analytical tool capable of complex analytical interrogation modes on sub-microliter sample volumes while also leveraging drastic noise rejection via lock-in detection. The multichannel μChopper device should prove particularly useful in analyzing precious biological samples or for dynamic analyses at small volume scales.
Collapse
Affiliation(s)
- Jean T. Negou
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | - Juan Hu
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | - Xiangpeng Li
- Department of Chemistry and Biochemistry, Auburn University, Auburn, AL 36849, USA
| | | |
Collapse
|
35
|
Direct sample injection from a syringe needle into a separation capillary. Anal Chim Acta 2018; 1042:133-140. [PMID: 30428980 DOI: 10.1016/j.aca.2018.07.026] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 07/05/2018] [Accepted: 07/10/2018] [Indexed: 11/22/2022]
Abstract
An automatic micro-injector was developed for electrophoretic analysis of a microlitre amount of clinical samples, enabling injection of the sample from a Hamilton syringe. The outlet of the syringe needle is located directly opposite the inlet of the separation capillary at a defined distance of the order of hundreds of μm in the injection space. During the injection, the background electrolyte is forced out by air from this space and a drop of the sample is forced out of the syringe by a micro-pump so that it is caught at the entrance to the capillary. From the drop the sample is injected into the capillary by applying a negative pressure pulse or simply by spontaneous injection. The injection space is then filled with background electrolyte, which washes away excess sample and separation is commenced. The injector was tested in electrophoretic separation of a model sample with equimolar concentrations of 100 μM NH4+, K+, Na+, Mg2+ and Li+ in a short capillary with total/effective length of 16.5/11.5 cm. The repeatability of the migration time and peak area expressed as the RSD value is 2% and 4%, respectively. The practical applicability of the injector was verified on the determination of the antiparasitic pentamidine in 10 μL of rat plasma. Electrophoretic separation of pentamidine was performed in 100 mM of acetic acid/NaOH at pH 4.55, the sample consumption per analysis is 125 nL, the separation time is 45 s and the attained LOQ using contactless conductivity detection is 8 μM.
Collapse
|
36
|
Ngernsutivorakul T, White TS, Kennedy RT. Microfabricated Probes for Studying Brain Chemistry: A Review. Chemphyschem 2018; 19:1128-1142. [PMID: 29405568 PMCID: PMC6996029 DOI: 10.1002/cphc.201701180] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Indexed: 12/13/2022]
Abstract
Probe techniques for monitoring in vivo chemistry (e.g., electrochemical sensors and microdialysis sampling probes) have significantly contributed to a better understanding of neurotransmission in correlation to behaviors and neurological disorders. Microfabrication allows construction of neural probes with high reproducibility, scalability, design flexibility, and multiplexed features. This technology has translated well into fabricating miniaturized neurochemical probes for electrochemical detection and sampling. Microfabricated electrochemical probes provide a better control of spatial resolution with multisite detection on a single compact platform. This development allows the observation of heterogeneity of neurochemical activity precisely within the brain region. Microfabricated sampling probes are starting to emerge that enable chemical measurements at high spatial resolution and potential for reducing tissue damage. Recent advancement in analytical methods also facilitates neurochemical monitoring at high temporal resolution. Furthermore, a positive feature of microfabricated probes is that they can be feasibly built with other sensing and stimulating platforms including optogenetics. Such integrated probes will empower researchers to precisely elucidate brain function and develop novel treatments for neurological disorders.
Collapse
Affiliation(s)
| | - Thomas S. White
- Macromolecular Science and Engineering, University of Michigan, 3003E, NCRC Building 28, 2800 Plymouth Rd., Ann Arbor, MI 48109
| | - Robert T. Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI 48109
- Department of Pharmacology, University of Michigan, 1150 W. Medical Center Drive, Ann Arbor, MI 48109
| |
Collapse
|
37
|
Saylor RA, Lunte SM. PDMS/glass hybrid device with a reusable carbon electrode for on-line monitoring of catecholamines using microdialysis sampling coupled to microchip electrophoresis with electrochemical detection. Electrophoresis 2018; 39:462-469. [PMID: 28737835 PMCID: PMC5783789 DOI: 10.1002/elps.201700211] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 07/12/2017] [Accepted: 07/12/2017] [Indexed: 01/16/2023]
Abstract
On-line separations-based sensors employing microdialysis (MD) coupled to microchip electrophoresis (ME) enable the continuous monitoring of multiple analytes simultaneously. Electrochemical detection (EC) is especially amenable to on-animal systems employing MD-ME due to its ease of miniaturization. However, one of the difficulties in fabricating MD-ME-EC systems is incorporating carbon working electrodes into the device. In this paper, a novel fabrication procedure is described for the production of a PDMS/glass hybrid device that is capable of integrating hydrodynamic MD flow with ME-EC using a flow-gated interface and a pyrolyzed photoresist film carbon electrode. This fabrication method enables the reuse of carbon electrodes on a glass substrate, while still maintaining a good seal between the PDMS and glass to allow for pressure-driven MD flow. The on-line MD-ME-EC device was characterized in vitro and in vivo for monitoring analytes in the dopamine metabolic pathway. The ultimate goal is to use this device and associated instrumentation to perform on-animal, near-real time in vivo monitoring of catecholamines.
Collapse
Affiliation(s)
- Rachel A. Saylor
- Department of Chemistry, University of Kansas, Lawrence, KS, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
| | - Susan M. Lunte
- Department of Chemistry, University of Kansas, Lawrence, KS, USA
- Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas, Lawrence, KS, USA
- Department of Pharmaceutical Chemistry, University of Kansas, Lawrence, KS, USA
| |
Collapse
|
38
|
ZHAN S, RUAN Y, LIU G, DING B, SHAO Q. [Experimental factors affecting in vitro recovery of puerarin in microdialysis]. Zhejiang Da Xue Xue Bao Yi Xue Ban 2018; 47:64-70. [PMID: 30146813 PMCID: PMC10393674 DOI: 10.3785/j.issn.1008-9292.2018.02.09] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2017] [Accepted: 09/18/2017] [Indexed: 06/08/2023]
Abstract
OBJECTIVE : To analyze experimental factors affecting in vitro recovery of puerarin in microdialysis. METHODS : Puerarin concentration in microdialysate samples was determined by high performance liquid chromatography. The methods of direct dialysis, retrodialysis and the zero-net flux were used to calculate in vitro recovery, respectively. The effects of perfusate composition, the analyte concentration, perfusate flow rate, medium temperature and stir rates of the dialysis medium on recovery were investigated. RESULTS : There were significant differences in the recovery values among direct dialysis, retrodialysis and zero-net flux methods. The recovery for 0.9% NaCl solution, Ringer's solution, PBS and anticoagulant dextrose solution as perfusate fluid were (71.25±2.36)%,(73.48±1.41)%,(68.50±2.43)% and (74.98±1.16)%, respectively. The composition of perfusate fluid had significant influence on the recovery(P<0.01). At the same flow rate, recovery was independent of the analyte concentration. At the same concentration, the recovery was decrease with the increasing flow rate in an exponential relationship. The recovery increased with the raising temperature and stir rate of the dialysis medium, and the recovery remained stable when the stir rate reached above 200 rpm. CONCLUSIONS : A study method for in vitro recovery of puerarin in microdialysis has been established, and the recovery of puerarin is affected by calculating methods, perfusate fluids, flow rate, medium temperature and stir rate, but not affected by analyte concentrations.
Collapse
Affiliation(s)
- Shuyu ZHAN
- ZHAN Shuyu, E-mail:
;
https://orcid.org/0000-0002-5973-6579
| | | | | | | | | |
Collapse
|
39
|
Tůma P, Heneberg P, Vaculín Š, Koval D. Electrophoretic large volume sample stacking for sensitive determination of the anti-microbial agent pentamidine in rat plasma for pharmacological studies. Electrophoresis 2018; 39:2605-2611. [DOI: 10.1002/elps.201700440] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2017] [Revised: 12/18/2017] [Accepted: 12/19/2017] [Indexed: 01/27/2023]
Affiliation(s)
- Petr Tůma
- Department of Hygiene; Third Faculty of Medicine; Charles University; Prague Czechia
| | - Petr Heneberg
- Third Faculty of Medicine; Charles University; Prague Czechia
| | - Šimon Vaculín
- Department of Normal; Pathological and Clinical Physiology; Third Faculty of Medicine; Charles University; Prague Czechia
| | - Dušan Koval
- Institute of Organic Chemistry and Biochemistry; The Czech Academy of Sciences; Prague Czechia
| |
Collapse
|
40
|
Brackin R, Atkinson BS, Sturrock CJ, Rasmussen A. Roots-eye view: Using microdialysis and microCT to non-destructively map root nutrient depletion and accumulation zones. PLANT, CELL & ENVIRONMENT 2017; 40:3135-3142. [PMID: 29057485 DOI: 10.1111/pce.13072] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Revised: 08/30/2017] [Accepted: 09/04/2017] [Indexed: 06/07/2023]
Abstract
Improvement in fertilizer use efficiency is a key aspect for achieving sustainable agriculture in order to minimize costs, greenhouse gas emissions, and pollution from nutrient run-off. To optimize root architecture for nutrient uptake and efficiency, we need to understand what the roots encounter in their environment. Traditional methods of nutrient sampling, such as salt extractions can only be done at the end of an experiment, are impractical for sampling locations precisely and give total nutrient values that can overestimate the nutrients available to the roots. In contrast, microdialysis provides a non-invasive, continuous method for sampling available nutrients in the soil. Here, for the first time, we have used microCT imaging to position microdialysis probes at known distances from the roots and then measured the available nitrate and ammonium. We found that nitrate accumulated close to roots whereas ammonium was depleted demonstrating that this combination of complementary techniques provides a unique ability to measure root-available nutrients non-destructively and in almost real time.
Collapse
Affiliation(s)
- Richard Brackin
- School of Agriculture and Food Sciences, The University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Brian S Atkinson
- Division of Agriculture and Environmental Science, School of Bioscience, The University of Nottingham, Sutton Bonington, LE12 5RD, UK
| | - Craig J Sturrock
- Division of Agriculture and Environmental Science, School of Bioscience, The University of Nottingham, Sutton Bonington, LE12 5RD, UK
| | - Amanda Rasmussen
- Division of Plant and Crop Science, School of Bioscience, The University of Nottingham, Sutton Bonington, LE12 5RD, UK
| |
Collapse
|
41
|
Ramos-Payán M, Ocaña-Gonzalez JA, Fernández-Torres RM, Llobera A, Bello-López MÁ. Recent trends in capillary electrophoresis for complex samples analysis: A review. Electrophoresis 2017; 39:111-125. [PMID: 28791719 DOI: 10.1002/elps.201700269] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 07/17/2017] [Accepted: 07/24/2017] [Indexed: 01/21/2023]
Abstract
CE has been a continuously evolving analytical methodology since its first introduction in the 1980s of the last century. The development of new CE separation procedures, the coupling of these systems to more sensitive and versatile detection systems, and the advances in miniaturization technology have allowed the application of CE to the resolution of new and complex analytical problems, overcoming the traditional disadvantages associated with this method. In the present work, different recent trends in CE and their application to the determination of high complexity samples (as biological fluids, individual cells, etc.) will be reviewed: capillary modification by different types of coatings, microfluidic CE, and online microextraction CE. The main advantages and disadvantages of the different proposed approaches will be discussed with examples of most recent applications.
Collapse
Affiliation(s)
- María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, Seville, Spain
| | - Juan A Ocaña-Gonzalez
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, Seville, Spain
| | | | - Andreu Llobera
- Carl Zeiss Vision GmbH, Technology & Innovation, Aalen, Germany
| | | |
Collapse
|
42
|
Petroni JM, Lucca BG, da Silva Júnior LC, Barbosa Alves DC, Souza Ferreira V. Paper-based Electrochemical Devices Coupled to External Graphene-Cu Nanoparticles Modified Solid Electrode through Meniscus Configuration and their Use in Biological Analysis. ELECTROANAL 2017. [DOI: 10.1002/elan.201700398] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
| | - Bruno Gabriel Lucca
- Departamento de Ciências Naturais; Universidade Federal do Espírito Santo; São Mateus, ES 29932-540 Brazil
| | | | | | - Valdir Souza Ferreira
- Instituto de Química; Universidade Federal de Mato Grosso do Sul; Campo Grande, MS 79074-460 Brazil
| |
Collapse
|
43
|
Integration of laminar flow extraction and capillary electrophoretic separation in one microfluidic chip for detection of plant alkaloids in blood samples. Anal Chim Acta 2017; 985:121-128. [DOI: 10.1016/j.aca.2017.05.036] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 05/10/2017] [Accepted: 05/30/2017] [Indexed: 12/21/2022]
|
44
|
Opekar F, Tůma P. Coaxial flow-gating interface for capillary electrophoresis. J Sep Sci 2017; 40:3138-3143. [DOI: 10.1002/jssc.201700412] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 05/22/2017] [Accepted: 05/23/2017] [Indexed: 12/24/2022]
Affiliation(s)
- František Opekar
- Faculty of Science, Department of Analytical Chemistry; Charles University; Prague 2 Czechia
| | - Petr Tůma
- Third Faculty of Medicine, Department of Biochemistry, Cell and Molecular Biology; Charles University; Prague 10 Czechia
| |
Collapse
|
45
|
Wang S, Liu X, Zhang M. Reduction of Ammineruthenium(III) by Sulfide Enables In Vivo Electrochemical Monitoring of Free Endogenous Hydrogen Sulfide. Anal Chem 2017; 89:5382-5388. [DOI: 10.1021/acs.analchem.7b00069] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Shujun Wang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Xiaomeng Liu
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| | - Meining Zhang
- Department of Chemistry, Renmin University of China, Beijing 100872, China
| |
Collapse
|
46
|
Components of Goutengsan in Rat Plasma by Microdialysis Sampling and Its Protection on A β1-42-Induced PC12 Cells Injury. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2017; 2017:7593027. [PMID: 28348625 PMCID: PMC5352969 DOI: 10.1155/2017/7593027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 02/20/2016] [Accepted: 05/12/2016] [Indexed: 12/11/2022]
Abstract
Goutengsan, a Chinese herbal formula, potential protection on Alzheimer's disease (AD) has been less reported. In current study, we investigated the protection of Goutengsan on Aβ1–42-induced pheochromocytoma-derived cells (PC12). Furthermore, the components from Goutengsan in rat plasma were identified by microdialysis (MD) for in vivo sampling. Meanwhile, the protection of components identified was also verified. At last, we found that Goutengsan has a potential protective effect on Aβ1–42-induced PC12 cells via reducing cells damage and increasing cells vitality as well as six components (pachymic acid, liquiritin, rhynchophylline, isorhynchophylline, corynoxeine, and isocorynoxeine) which may be effective components. This study helps to understand the treatment of Goutengsan for AD and would facilitate the clinical and further studies for this formula.
Collapse
|
47
|
Rodeberg NT, Sandberg SG, Johnson JA, Phillips PEM, Wightman RM. Hitchhiker's Guide to Voltammetry: Acute and Chronic Electrodes for in Vivo Fast-Scan Cyclic Voltammetry. ACS Chem Neurosci 2017; 8:221-234. [PMID: 28127962 PMCID: PMC5783156 DOI: 10.1021/acschemneuro.6b00393] [Citation(s) in RCA: 135] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Fast-scan cyclic voltammetry (FSCV) has been used for over 20 years to study rapid neurotransmission in awake and behaving animals. These experiments were first carried out with carbon-fiber microelectrodes (CFMs) encased in borosilicate glass, which can be inserted into the brain through micromanipulators and guide cannulas. More recently, chronically implantable CFMs constructed with small diameter fused-silica have been introduced. These electrodes can be affixed in the brain with minimal tissue response, which permits longitudinal measurements of neurotransmission in single recording locations during behavior. Both electrode designs have been used to make novel discoveries in the fields of neurobiology, behavioral neuroscience, and psychopharmacology. The purpose of this Review is to address important considerations for the use of FSCV to study neurotransmitters in awake and behaving animals, with a focus on measurements of striatal dopamine. Common issues concerning experimental design, data collection, and calibration are addressed. When necessary, differences between the two methodologies (acute vs chronic recordings) are discussed. The topics raised in this Review are particularly important as the field moves beyond dopamine toward new neurochemicals and brain regions.
Collapse
Affiliation(s)
- Nathan T. Rodeberg
- Department of Chemistry and ‡Neuroscience
Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290, United States
- Department of Psychiatry
and Behavioral Sciences and ∥Department of Pharmacology, University of Washington, Seattle, Washington 98195-6560, United States
| | - Stefan G. Sandberg
- Department of Chemistry and ‡Neuroscience
Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290, United States
- Department of Psychiatry
and Behavioral Sciences and ∥Department of Pharmacology, University of Washington, Seattle, Washington 98195-6560, United States
| | - Justin A. Johnson
- Department of Chemistry and ‡Neuroscience
Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290, United States
- Department of Psychiatry
and Behavioral Sciences and ∥Department of Pharmacology, University of Washington, Seattle, Washington 98195-6560, United States
| | - Paul E. M. Phillips
- Department of Chemistry and ‡Neuroscience
Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290, United States
- Department of Psychiatry
and Behavioral Sciences and ∥Department of Pharmacology, University of Washington, Seattle, Washington 98195-6560, United States
| | - R. Mark Wightman
- Department of Chemistry and ‡Neuroscience
Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599-3290, United States
- Department of Psychiatry
and Behavioral Sciences and ∥Department of Pharmacology, University of Washington, Seattle, Washington 98195-6560, United States
| |
Collapse
|
48
|
Ngo KT, Varner EL, Michael AC, Weber SG. Monitoring Dopamine Responses to Potassium Ion and Nomifensine by in Vivo Microdialysis with Online Liquid Chromatography at One-Minute Resolution. ACS Chem Neurosci 2017; 8:329-338. [PMID: 28094974 DOI: 10.1021/acschemneuro.6b00383] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Recently, our laboratory has demonstrated the technical feasibility of monitoring dopamine at 1 min temporal resolution with microdialysis and online liquid chromatography. Here, we monitor dopamine in the rat striatum during local delivery of high potassium/low sodium or nomifensine in awake-behaving rats. Microdialysis probes were implanted and perfused continuously with or without dexamethasone in the perfusion fluid for 4 days. Dexamethasone is an anti-inflammatory agent that exhibits several positive effects on the apparent health of the brain tissue surrounding microdialysis probes. Dopamine was monitored 1 or 4 days after implantation under basal conditions, during 10 min applications of 60 mM or 100 mM K+, and during 15 min applications of 10 μM nomifensine. High K+ and nomifensine were delivered locally by adding them to the microdialysis perfusion fluid using a computer-controlled, low-dead-volume six-port valve. Each day/K+/dexamethasone combination elicited specific dopamine responses. Dexamethasone treatment increased dopamine levels in basal dialysates (i.e., in the absence of K+ or nomifensine). Applications of 60 mM K+ evoked distinct responses on days one and four after probe implantation, depending upon the presence or absence of dexamethasone, consistent with dexamethasone's ability to mitigate the traumatic effect of probe implantation. Applications of 100 mM K+ evoked dramatic oscillations in dopamine levels that correlated with changes in the field potential at a metal electrode implanted adjacent to the microdialysis probe. This combination of results indicates the role of spreading depolarization in response to 100 mM K+. With 1 min temporal resolution, we find that it is possible to characterize the pharmacokinetics of the response to the local delivery of nomifensine. Overall, the findings reported here confirm the benefits arising from the ability to monitor dopamine via microdialysis at high sensitivity and at high temporal resolution.
Collapse
Affiliation(s)
- Khanh T. Ngo
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Erika L. Varner
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Adrian C. Michael
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| | - Stephen G. Weber
- Department of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, United States
| |
Collapse
|
49
|
Petroni JM, Lucca BG, Ferreira VS. Simple approach for the fabrication of screen-printed carbon-based electrode for amperometric detection on microchip electrophoresis. Anal Chim Acta 2017; 954:88-96. [DOI: 10.1016/j.aca.2016.12.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2016] [Revised: 12/07/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
|
50
|
David Hopper L. Automated Microsampling Technologies and Enhancements in the 3Rs. ILAR J 2017; 57:166-177. [DOI: 10.1093/ilar/ilw020] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2016] [Revised: 08/11/2016] [Accepted: 08/12/2016] [Indexed: 01/01/2023] Open
|