1
|
Alhotan A, Alaqeely R, Al-Johani H, Alrobaish S, Albaiz S. Effect of simulated gastric acid exposure on the hardness, topographic, and colorimetric properties of machinable and pressable zirconia-reinforced lithium silicate glass-ceramics. J Prosthet Dent 2024; 132:625.e1-625.e7. [PMID: 38997892 DOI: 10.1016/j.prosdent.2024.06.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Revised: 06/20/2024] [Accepted: 06/21/2024] [Indexed: 07/14/2024]
Abstract
STATEMENT OF PROBLEM The effects of gastric acid on the hardness, topographic, and colorimetric properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remain unknown. PURPOSE The purpose of this in vitro study was to investigate the effect of simulated gastric acid exposure on the microhardness, surface roughness, color stability, and relative translucency of ZLSs. MATERIAL AND METHODS Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD)(n=64) were randomly allocated to artificial saliva (control) or gastric juice immersion groups simulating 10 and 20 years of clinical exposure. Microhardness (Hv) was measured with a Vickers hardness device, and surface roughness (Sa) was recorded with an optical profilometer. The color stability (ΔE00) and relative translucency parameter (RTP) were measured with a spectrophotometer. Data for Hv, Sa, and RTP were analyzed by repeated 2-way ANOVA, and data for ΔE00 were analyzed by 2-way ANOVA. Post hoc comparisons were obtained from Tukey HSD and Student t tests (α=.05). RESULTS Machinable ZLSs exhibited greater Hv after the simulated gastric acid challenge than pressable ZLSs. Sa was significantly impacted by material type (P=.001), storage media (P=.050), and their interaction (P<.001). ΔE00 was significantly affected by the type of simulated aging media (P<.001). After 20 years of simulated gastric acid aging, all ZLS materials surpassed the ΔE00 perceptibility threshold but did not exceed the ΔE00 acceptability threshold. VS displayed significantly lower RTP than other ZLS materials at all time points (P<.001). CONCLUSIONS The topographic and colorimetric characteristics of ZLS were significantly altered by exposure to simulated gastric acid.
Collapse
Affiliation(s)
- Abdulaziz Alhotan
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Razan Alaqeely
- Assistant Professor, Department of Periodontics, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Hanan Al-Johani
- PhD student, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK.
| | - Shahad Alrobaish
- Dental Intern, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Sarah Albaiz
- Dental Intern, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
2
|
Robaian A. Effect of trialkoxysilane/aminosilane-containing universal adhesive on resin-ceramic microtensile bond strength and ceramic wettability: An in-vitro study. Heliyon 2024; 10:e34112. [PMID: 39113958 PMCID: PMC11305263 DOI: 10.1016/j.heliyon.2024.e34112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 06/25/2024] [Accepted: 07/03/2024] [Indexed: 08/10/2024] Open
Abstract
Background The dual-silane (trialkoxysilane/aminosilane) universal adhesive (UA) is claimed for its enhanced priming capacity of glass-ceramics. Objective This study evaluated the effect of organofunctional trialkoxysilane- and organofunctional trialkoxysilane/aminosilane-containing UAs on the long-term resin-ceramic microtensile bond strength (μTBS) and wettability of ceramic. Methods Hydrofluoric acid-etched lithium disilicate discs were distributed into four groups as follows: (control), no priming was performed; (MBN), primed using a silane-based primer (Monobond N); (SBU), primed using a trialkoxysilane-containing UA (Single Bond Universal Adhesive) and (SBP), primed using a trialkoxysilane/aminosilane-containing UA (Scotchbond Universal Plus Adhesive). Ceramic discs were cemented into blocks then sectioned into microbeams stored in distilled water at 37° for 1 year. The μTBS was evaluated followed by assessment of the failure modes. The contact angle of the two UAs was measured with a goniometer using the sessile drop technique. Results MBN significantly improved the resin-ceramic μTBS (31.71 ± 6.33 MPa) compared to the control group. The resin-ceramic μTBS obtained after priming using SBP (22.83 ± 3.42 MPa) was comparable to those of MBN. SBU showed significantly inferior resin-ceramic μTBS (16.02 ± 6.28 MPa) compared with MBN. Mixed failures mode patterns were the most frequent in the groups. The ceramic wettability of both UAs did not significantly differ. Conclusion Ceramic priming using a UA with dual-silane monomers (organofunctional trialkoxysilane/aminosilane) resulted in long-term adhesion comparable to a silane-containing primer. Incorporating aminosilane monomer in UA formulation did not affect the wetting of characteristics of the UA solution and enhanced its glass-ceramic priming capacity. Clinical significance The use of UA with optimized silane content as a primer for glass-ceramics simplifies clinical adhesive procedures including resin cementation and repair of ceramic restorations.
Collapse
Affiliation(s)
- Ali Robaian
- Department of Conservative Dental Sciences, The College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, 11942, Saudi Arabia
| |
Collapse
|
3
|
Lu Y, Bierman TE, Dal Piva AMDO, Tribst JPM, Feilzer AJ, Kleverlaan CJ. Effect of Surface Treatment and Resin Cement on the Bond Strength of an Advanced Lithium Disilicate. Eur J Dent 2024; 18:869-876. [PMID: 38198813 PMCID: PMC11290925 DOI: 10.1055/s-0043-1776358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024] Open
Abstract
OBJECTIVES The aim of the study was to evaluate the effect of surface treatment and resin cement on the bond strength of conventional and advanced lithium disilicates (ALDs). MATERIALS AND METHODS Ceramic slices (2 × 13 × 15 mm) of conventional lithium disilicate (LD) (IPS e.max CAD) and ALD (CEREC Tessera) were sectioned, polished, and divided into 16 groups (n = 10) according to the factors: ceramic, surface treatment, and resin cement (Panavia V5 and Variolink Esthetic DC). Surface treatments consisted of hydrofluoric acid 4.9% etching for 20 seconds (Hf20) or 30 seconds (Hf30), self-etching ceramic primer (Se), and sandblasting (Sb). Then, a resin cement cylinder (Ø = 2.5 mm) was manufactured on each specimen's surface. The specimens were then submitted to a shear bond strength (SBS) test. Surface roughness was evaluated through a contact profilometer, and surface morphology was evaluated under scanning electron microscopy for qualitative analysis. STATISTICAL ANALYSIS Two-way analysis of variance (ANOVA) was used to analyze the data of SBS and surface roughness. For bond strength, the effects of surface treatment, resin cement, and the interaction were analyzed for each ceramic. For roughness, analyzed factors include ceramic and surface treatment. RESULTS ANOVA revealed that ceramic (p = 0.047) and surface treatment (p < 0.001) factors affected the bond strength, while the cements performed similarly. Both materials showed adequate bond strength (ALD 19.1 ± 7.7 MPa; LD 17.1 ± 7.9 MPa). Sb protocol showed the lowest mean value (9.6 ± 2.9 MPa) compared with Hf20 (22.0 ± 7.1 MPa), Hf30 (21.7 ± 7.4 MPa), and Se (19.3 ± 6.0 MPa). CONCLUSION For both ceramics, the highest performance was obtained after applying Se and Hf20 or Hf30. Therefore, longer etching time is unnecessary. Sb protocol must be avoided.
Collapse
Affiliation(s)
- Yuqing Lu
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Thera Elisa Bierman
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Albert J. Feilzer
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
- Department of Reconstructive Oral Care, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Cornelis J. Kleverlaan
- Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Bawazir M, Lim C, Arnés-Urgellés P, Lu M, Huang H, Zhang Y. Brittle-Ductile Threshold in Lithium Disilicate under Sharp Sliding Contact. J Dent Res 2024; 103:839-847. [PMID: 38877734 PMCID: PMC11307199 DOI: 10.1177/00220345241256279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2024] Open
Abstract
Computer-aided design (CAD)/computer-aided manufacturing (CAM) milling and handpiece grinding are critical procedures in the fabrication and adjustment of ceramic dental restorations. However, due to the formation of microfractures, these procedures are detrimental to the strength of ceramics. This study analyzes the damage associated with current brittle-regime grinding and presents a potential remedy in the application of a safer yet still efficient grinding regime known as "ductile-regime grinding." Disc-shaped specimens of a lithium disilicate glass-ceramic material (IPS e.max CAD) were obtained by cutting and crystallizing the lithium metasilicate CAD/CAM blanks (the so-called blue blocks) following the manufacturer's instructions. The discs were then polished to a 1 µm diamond suspension finish. Single-particle micro-scratch tests (n = 10) with a conical diamond indenter were conducted to reproduce basic modes of deformation and fracture. Key parameters such as coefficient of friction and penetration depth were recorded as a function of scratch load. Further, biaxial flexure strength tests (n = 6) were performed after applying various scratch loads to analyze their effects on ceramic strength. Scanning electron microscopy (SEM) and focused ion beam (FIB) were used to characterize surface and subsurface damage. Statistical analysis was performed using one-way analysis of variance and Tukey tests. While the SEM surface analysis of scratch tracks revealed the occurrence of both ductile and brittle removal modes, it failed to accurately determine the threshold load for the brittle-ductile transition. The threshold load for brittle-ductile transition was determined to be 70 mN based on FIB subsurface damage analyses in conjunction with strength degradation studies. Below 70 mN, the specimens exhibited neither strength degradation nor the formation of subsurface cracks. Determination of the brittle-ductile thresholds is significant because it sets a foundation for future research on the feasibility of implementing ductile-regime milling/grinding protocols for fabricating damage-free ceramic dental restorations.
Collapse
Affiliation(s)
- M. Bawazir
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Restorative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - C.H. Lim
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - P. Arnés-Urgellés
- School of Mechanical and Mining Engineering, The University of Queensland, St Lucia, QLD, Australia
| | - M. Lu
- School of Mechanical and Mining Engineering, The University of Queensland, St Lucia, QLD, Australia
| | - H. Huang
- School of Mechanical and Mining Engineering, The University of Queensland, St Lucia, QLD, Australia
- School of Advanced Manufacturing, Sun Yat-sen University (Shenzhen Campus), China
| | - Y. Zhang
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
5
|
Jiang Q, Wang Z, Zhang S, Liu X, Fu B. Performance of Bonded Lithium Disilicate Partial-coverage Crowns in the Restoration of Endodontically Treated Posterior Teeth: An Up to Seven-Year Retrospective Study. Oper Dent 2024; 49:365-375. [PMID: 38978317 DOI: 10.2341/23-107-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/09/2024] [Indexed: 07/10/2024]
Abstract
OBJECTIVES To evaluate the clinical performance of adhesively bonded lithium disilicate glass-ceramic (LDG) partial-coverage crowns in restoring posterior endodontically treated teeth (ETT). METHODS AND MATERIALS A total of 121 morphologically compromised posterior ETT were restored with LDG partial-coverage crowns between October 2015 and January 2018. The restorations were fabricated in the laboratory or at the chairside. Two adhesive systems and resin cements were used to cement the restorations. Tooth and restoration survival rates were calculated. The restorations were evaluated clinically using the modified United States Public Health Service (USPHS) criteria for an observation period of 5-7 years. The Cox proportional hazards model was used to estimate relative failure risks such as tooth type, resin cements, gender, and sleep bruxism. The standard chi-squared test was used to compare the survival of different tooth types for significant differences (α=0.05). In addition, survival probability was calculated using the Kaplan-Meier algorithm. RESULTS Among seven failed cases, one was a tooth fracture, and six were restoration fractures. According to the Kaplan-Meier analysis, the estimated survival rate of the teeth was 99% for seven years, while the estimated survival rate of the restorations was 94.8% for 5 years and 92.8% for 7 years. Tooth type and resin cements did not influence restoration survival rates (p>0.05), while sleep bruxism and male patients might increase the risk of failure (p<0.05). CONCLUSIONS The indirect adhesively bonded LDG partial-coverage crowns of posterior ETT exhibited favorable clinical outcomes. Ceramic fracture was the most common failure pattern.
Collapse
Affiliation(s)
- Q Jiang
- Qin Jiang, MD, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - Z Wang
- Zhe Wang, PhD, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - S Zhang
- Sisi Zhang, BDS, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - X Liu
- Xiaochen Liu, PhD, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| | - B Fu
- *Baiping Fu, DMD, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, China
| |
Collapse
|
6
|
Rizk A, Abdou A, Ashraf R, Omar S. Effect of multiple firings on optical and mechanical properties of Virgilite-containing lithium disilicate glass-ceramic of varying thickness. Clin Oral Investig 2024; 28:370. [PMID: 38869624 PMCID: PMC11176229 DOI: 10.1007/s00784-024-05746-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Accepted: 05/24/2024] [Indexed: 06/14/2024]
Abstract
OBJECTIVES To investigate the effect of multiple firings on color, translucency, and biaxial flexure strength of Virgilite-containing (Li0.5Al0.5Si2.5O6) lithium disilicate glass ceramics of varying thickness. MATERIALS AND METHODS Sixty discs were prepared from Virgilite-containing lithium disilicate blocks. Discs were divided according to thickness (n = 30) into T0.5 (0.5 mm) and T1.0 (1.0 mm). Each thickness was divided according to the number of firing cycles (n = 10); F1 (Control group): 1 firing cycle; F3: 3 firing cycles, and F5: 5 firing cycles. The discs were tested for color change (ΔE00) and translucency (TP00) using a spectrophotometer. Then, all samples were subjected to biaxial flexure strength testing using a universal testing machine. Data were collected and statistically analyzed (α = 0.5). For chemical analysis, six additional T0.5 discs (2 for each firing cycle) were prepared; for each firing cycle one disc was subjected to X-ray diffraction analysis (XRD) and another disc was subjected to Energy dispersive X-ray spectroscopy (EDX) and Scanning electron microscope (SEM). RESULTS Repeated firing significantly reduced the translucency of F3 and F5 compared to F1 in T0.5 (p < 0.001), while for T1.0 only F5 showed a significant decrease in TP00 (p < 0.001). For ΔE00, a significant increase was recorded with repeated firings (p < 0.05) while a significant decrease resulted in the biaxial flexure strength regardless of thickness. CONCLUSIONS Repeated firings had a negative effect on both the optical and mechanical properties of the Virgilite-containing lithium disilicate glass ceramics. CLINICAL RELEVANCE Repeated firings should be avoided with Virgilite-containing lithium disilicate ceramics to decrease fracture liability and preserve restoration esthetics.
Collapse
Affiliation(s)
- Amr Rizk
- Department of Prosthetic Dentistry, Fixed Prosthodontics Division, Faculty of Dentistry, King Salman International University, South Sinai, Egypt.
| | - Ahmed Abdou
- Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Reem Ashraf
- Department of Prosthetic Dentistry, Dental Biomaterials Division, Faculty of Dentistry, King Salman International University, South Sinai, Egypt
| | - Sarah Omar
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Badr University in Cairo, Cairo, Egypt
| |
Collapse
|
7
|
Fouda AM, Bourauel C, Samran A, Kassem AS, Alhotan A. Effect of glazing and thermocycling on the fracture toughness and hardness of a New fully crystallized aluminosilicate CAD/CAM ceramic material. BMC Oral Health 2024; 24:620. [PMID: 38807109 PMCID: PMC11131322 DOI: 10.1186/s12903-024-04398-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 05/22/2024] [Indexed: 05/30/2024] Open
Abstract
BACKGROUND The mechanical properties of fully crystallized lithium aluminosilicate ceramics may be influenced by intraoral temperature variations and postmilling surface treatment. The purpose of this study is to explore the interplay among glazing, thermocycling, and the mechanical characteristics (namely, fracture toughness and hardness) of fully crystallized lithium aluminosilicate ceramics. METHODS Bending bars (n = 40) cut from LisiCAD blocks (GC, Japan) were randomly assigned to glazed or unglazed groups (n = 20) and subjected to the single edge v-notch beam method to create notches. A glazing firing cycle was applied to the glazed group, while the unglazed group was not subjected to glazing. Half of the specimens (n = 10) from both groups underwent thermocycling before fracture toughness testing. The fracture toughness (KIC) was evaluated at 23 ± 1 °C using a universal testing machine configured for three-point bending, and the crack length was measured via light microscopy. Seven specimens per group were selected for the hardness test. Hardness was assessed using a Vickers microhardness tester with a 1 kg load for 20 s, and each specimen underwent five indentations following ISO 14705:2016. The Shapiro-Wilk and Kolmogorov-Smirnov tests were used to evaluate the normality of the data and a two-way ANOVA was utilized for statistical analysis. The significance level was set at (α = 0.05). RESULTS Regardless of the thermocycling conditions, the glazed specimens exhibited significantly greater fracture toughness than did their unglazed counterparts (P < 0.001). Thermocycling had no significant impact on the fracture toughness of either the glazed or unglazed specimens. Furthermore, statistical analysis revealed no significant effects on hardness with thermocycling in either group, and glazing alone did not substantially affect hardness. CONCLUSIONS The impact of glazing on the fracture toughness of LiSiCAD restorations is noteworthy, but it has no significant influence on their hardness. Furthermore, within the parameters of this study, thermocycling was found to exert negligible effects on both fracture toughness and hardness.
Collapse
Affiliation(s)
- Ahmed Mahmoud Fouda
- Department of Oral Technology, Medical Faculty, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany.
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt.
| | - Christoph Bourauel
- Department of Oral Technology, Medical Faculty, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, North Rhine-Westphalia, Germany
| | - Abdulaziz Samran
- Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al-Uloom University, Riyadh, Saudi Arabia
- Department of Prosthodontics, School of Dentistry, Ibb University, Ibb, Yemen
| | - Amr Shebl Kassem
- Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, 7 Riyadh 12372, P.O. Box 10219, Riyadh, Saudi Arabia
| |
Collapse
|
8
|
Demirel M, Donmez MB. Fabrication trueness and internal fit of different lithium disilicate ceramics according to post-milling firing and material type. J Dent 2024; 144:104987. [PMID: 38580056 DOI: 10.1016/j.jdent.2024.104987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/29/2024] [Accepted: 04/02/2024] [Indexed: 04/07/2024] Open
Abstract
OBJECTIVES To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.
Collapse
Affiliation(s)
- Münir Demirel
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
9
|
Lohbauer U, Fabris DCN, Lubauer J, Abdelmaseh S, Cicconi MR, Hurle K, de Ligny D, Goetz-Neunhoeffer F, Belli R. Glass science behind lithium silicate glass-ceramics. Dent Mater 2024; 40:842-857. [PMID: 38580561 DOI: 10.1016/j.dental.2024.03.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 03/28/2024] [Accepted: 03/29/2024] [Indexed: 04/07/2024]
Abstract
OBJECTIVES Lithium silicate-based glass ceramics have evolved as a paramount restorative material in restorative and prosthetic dentistry, exhibiting outstanding esthetic and mechanical performance. Along with subtractive machining techniques, this material class has conquered the market and satisfied the patients' needs for a long-lasting, excellent, and metal-free alternative for single tooth replacements and even smaller bridgework. Despite the popularity, not much is known about the material chemistry, microstructure and terminal behaviour. METHODS This article combines a set of own experimental data with extensive review of data from literature and other resources. Starting at manufacturer claims on unique selling propositions, properties, and microstructural features, the aim is to validate those claims, based on glass science. Deep knowledge is mandatory for understanding the microstructure evolution during the glass ceramic process. RESULTS Fundamental glass characteristics have been addressed, leading to formation of time-temperature-transformation (TTT) diagrams, which are the basis for kinetic description of the glass ceramic process. Nucleation and crystallization kinetics are outlined in this contribution as well as analytical methods to describe the crystalline fraction and composition qualitatively and quantitatively. In relation to microstructure, the mechanical performance of lithium silicate-based glass ceramics has been investigated with focus on fracture strength versus fracture toughness as relevant clinical predictors. CONCLUSION Fracture toughness has been found to be a stronger link to initially outlined manufacturer claims, and to more precisely match ISO recommendations for clinical indications.
Collapse
Affiliation(s)
- Ulrich Lohbauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany.
| | - Débora Cristina Niero Fabris
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany
| | - Julia Lubauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany
| | - Samuel Abdelmaseh
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Department Werkstoffwissenschaften, Institut für Glas und Keramik, Martensstrasse 5, 91058 Erlangen, Germany
| | - Maria-Rita Cicconi
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Department Werkstoffwissenschaften, Institut für Glas und Keramik, Martensstrasse 5, 91058 Erlangen, Germany
| | - Katrin Hurle
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), GeoZentrum Nordbayern, Mineralogy, Schlossgarten 5a, 91054 Erlangen, Germany
| | - Dominique de Ligny
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Department Werkstoffwissenschaften, Institut für Glas und Keramik, Martensstrasse 5, 91058 Erlangen, Germany
| | - Friedlinde Goetz-Neunhoeffer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), GeoZentrum Nordbayern, Mineralogy, Schlossgarten 5a, 91054 Erlangen, Germany
| | - Renan Belli
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany
| |
Collapse
|
10
|
Stawarczyk B, Meinen J, Wuersching SN. Two-body wear of novel monolithic lithium-silicate ceramic materials and their corresponding different antagonists. J Dent 2024; 144:104952. [PMID: 38508442 DOI: 10.1016/j.jdent.2024.104952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 03/15/2024] [Accepted: 03/16/2024] [Indexed: 03/22/2024] Open
Abstract
OBJECTIVES Evaluation of the two-body wear of lithium-silicate ceramics against different antagonists compared to a direct resin composite and human teeth. METHODS Initial LiSi Block [LISI], IPS e.max CAD [EMA], and CEREC Tessera [TESE] were investigated and compared with direct resin composite [FILL] and human teeth [tooth]. As antagonists were used: steatite, ceramic, and human enamel. The control group tooth was only tested with enamel antagonist. The combinations underwent thermomechanical aging using a chewing simulator. Material losses were calculated using GOM-analysis software. Kolmogorov-Smirnov test, Kruskal-Wallis H, Mann-Whitney-U-test with Bonferroni correction and Spearman-rho correlation were calculated. A fractographic analysis was performed. RESULTS Within TESE, enamel antagonists led to lower restoration losses than steatite and ceramic antagonists. Within FILL, enamel and steatite antagonists caused lower material losses compared to ceramic antagonists. Against steatite antagonists, LISI showed lowest material losses. Against ceramic antagonists, the use of LISI led to lower material losses compared to FILL. Against tooth antagonists, TESE showed lower material losses than tooth and FILL and LISI lower than FILL. Within LISI, steatite antagonists showed lower material losses on the antagonist than ceramic. Within EMA, steatite antagonists showed higher material losses than ceramic ones. Within ceramic antagonists, LISI restoration material showed lower material losses than FILL and EMA. CONCLUSIONS Regardless of the antagonist material, the material losses of LISI and EMA were comparable. However, the abrasion resistance of LISI tended to be higher than EMA. CLINICAL SIGNIFICANCE LISI is a fully crystallized lithium-silicate ceramic and no longer needs to be processed after milling. In addition, the abrasion resistance is very good, regardless of the antagonist material chosen.
Collapse
Affiliation(s)
- Bogna Stawarczyk
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany.
| | - John Meinen
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| | - Sabina Noreen Wuersching
- Department of Conservative Dentistry and Periodontology, University Hospital, LMU Munich, Goethestraße 70, 80336 Munich, Germany
| |
Collapse
|
11
|
Pérez JA, Rodríguez-Rojas F, Borrero-López Ó, Sánchez-González E. Effect of Post-Processing Heat Treatment on Micro-Contact Damage of Zirconia-Reinforced Lithium Silicate Dental Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1961. [PMID: 38730767 PMCID: PMC11084880 DOI: 10.3390/ma17091961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/17/2024] [Accepted: 04/19/2024] [Indexed: 05/13/2024]
Abstract
Zirconia-reinforced lithium silicate (ZLS) is utilized as a material for prosthetic tooth crowns, offering enhanced strength compared to other dental glass-ceramics. In this study, we investigate a commercial ZLS material, provided in a fully crystallized form. We examine the effects of an optional post-processing heat treatment on micro-contact damage using controlled indentation tests simulating the primary modes of contact during chewing: axial and sliding. Our findings indicate that the heat treatment does not affect mechanical properties such as the elastic modulus, hardness and indentation fracture toughness. However, it does enhance the resistance to contact damage by fracture and chipping in both axial and sliding modes, as well as the resistance to crack initiation measured from sliding tests. This improvement is attributed to the refinement of the flaw population achieved through the heat treatment. The results are analysed using principles of contact and fracture mechanics theory, discussing their significance in prosthetic dentistry.
Collapse
Affiliation(s)
| | | | | | - Estíbaliz Sánchez-González
- Departamento de Ingeniería Mecánica, Energética y de los Materiales, Universidad de Extremadura, 06006 Badajoz, Spain; (J.A.P.); (F.R.-R.); (Ó.B.-L.)
| |
Collapse
|
12
|
Bondzior B. Isochemical crystallization in condensed borate LaMgB 5O 10 glass-ceramics doped with optical probe Eu 3. OPTICS LETTERS 2024; 49:2125-2128. [PMID: 38621092 DOI: 10.1364/ol.521244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 03/18/2024] [Indexed: 04/17/2024]
Abstract
The isochemical glass-ceramics doped with Eu3+ were prepared by the heat treatment of lanthanum magnesium borate glass. The crystalline phase was chemically identical to a glass matrix and consisted of condensed borate LaMgB5O10. The isochemical crystallization process begins with the formation of rings by BO4 groups. The emergence of ordered crystalline phase gives rise to intense charge transfer absorption of Eu3+, allowing the efficient luminescence under UV. The analysis of Judd-Ofelt parameters and comparison to purely crystalline samples obtained by solid-state synthesis reveal a switch of parameter relations from Ω2 > Ω4 for glass to Ω2 < Ω4 for crystals but also a maximum value of Ω6 for glass-ceramic sample, which indicates enhanced structural rigidity and results in superior luminescence output. The quantum yield measurements confirmed higher luminescence efficiency for glass-ceramics compared to both pure glass and pure crystalline samples.
Collapse
|
13
|
Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of repeated firing on the topographical, optical, and mechanical properties of fully crystallized lithium silicate-based ceramics. J Prosthet Dent 2024; 131:741.e1-741.e11. [PMID: 38242762 DOI: 10.1016/j.prosdent.2024.01.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 01/02/2024] [Accepted: 01/05/2024] [Indexed: 01/21/2024]
Abstract
STATEMENT OF PROBLEM The influence of different firing protocols on the topographical, optical, and mechanical properties of fully crystallized computer-aided design and computer-aided manufacturing (CAD-CAM) lithium silicate-based glass-ceramics (LSCs) for dental restorations remains unclear. PURPOSE The purpose of this in vitro study was to investigate the effect of different firing regimens on the surface roughness, gloss, Martens hardness, indentation modulus, biaxial flexural strength, and crystalline structure of fully crystallized CAD-CAM LSCs and the effect of their interposition on the irradiance of a light-polymerization unit. MATERIAL AND METHODS Three fully crystallized CAD-CAM LSC blocks were evaluated (N=150): lithium disilicate (Initial LiSi Blocks; LS), zirconia-reinforced silicate (Celtra Duo; CD), and lithium aluminum disilicate (CEREC Tessera; CT). Specimens were allocated to 5 subgroups according to their firing protocol. LSC roughness (Sa) was measured with an optical profilometer, and gloss (GU) was detected with a gloss meter. Martens hardness (HM) and indentation modulus (EIT) data were obtained from a hardness testing machine. The irradiance of a light-polymerization unit and transmittance of LSCs were measured with an instrument (Managing Accurate Resin Curing-Light Collector; BlueLight analytics, Inc) subsequent to ceramic interposition. Crystalline phases were analyzed by X-ray diffraction, and biaxial flexural strength (σ) was determined by the ball-on-3-ball method in a universal testing machine followed by Weibull analysis to calculate characteristic strength (σ0) and Weibull modulus (m). Two-way ANOVA and Tukey HSD post hoc tests (α=.05) were used to analyze the data. RESULTS Statistically significant differences were found among different treatment groups based on Sa, GU, HM, and EIT values (P<.001). Delivered irradiance was significantly reduced following CT (P<.01) and glazed LSC (P<.005) interposition. CD displayed highest biaxial flexural strength and reliability after 1 firing cycle (σ=568.2 MPa, m=16.8) CONCLUSIONS: The type of material and firing regimens had a significant effect on the topographical, optical, and mechanical properties of fully crystallized CAD-CAM LSCs. Glazing significantly reduced delivered irradiance, Martens hardness, and biaxial flexural strength.
Collapse
Affiliation(s)
- Hanan Al-Johani
- PhD student, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| | - Julfikar Haider
- Associate Professor, Department of Engineering, Manchester Metropolitan University, Manchester, England, UK
| | - Nick Silikas
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK.
| | - Julian Satterthwaite
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| |
Collapse
|
14
|
Bresser RA, Carvalho MA, Naves LZ, Melma H, Cune MS, Gresnigt MMM. Biomechanical behavior of molars restored with direct and indirect restorations in combination with deep margin elevation. J Mech Behav Biomed Mater 2024; 152:106459. [PMID: 38394767 DOI: 10.1016/j.jmbbm.2024.106459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 01/30/2024] [Accepted: 02/05/2024] [Indexed: 02/25/2024]
Abstract
STATEMENT OF PROBLEM The existing knowledge is insufficient for comprehending the fatigue survival and fracture resistance of molars that have deep approximal direct and indirect restorations, whether with or without deep margin elevation (DME). PURPOSE The aim of this laboratory and in silico study is to investigate the fatigue survival, fracture strength, failure pattern and tooth deformation of molars restored with DME in combination with a direct or indirect restoration. MATERIAL AND METHODS This study utilized 45 extracted sound human molars, divided into three groups (n = 15). Standardized 100% inter-cuspal inlay preparations were performed, extending 2 mm below the CEJ and immediate dentin sealing (IDS) was applied. Group 1 (Co_1) was restored with direct composite; Group 2 (Hyb_2) with a 2 mm DME of direct composite and a glass-ceramic lithium disilicate restoration; Group 3 (Cer_3) a glass-ceramic lithium disilicate restoration. All specimens were exposed to a fatigue process involving thermal-cyclic loading (50N for 1.2 × 106 cycles at 1.7 Hz, between 5 and 55 °C), if teeth survived, they were fractured using a load-to-failure test and failure types were analyzed. Finite element analysis (FEA) was conducted to assess tooth deformation and tensile stress in the restorations. Statistical evaluation of fracture strength was conducted using the Kruskal-Wallis test. Fisher's exact test was utilized to analyze the fracture types and repairability. A statistical significance level of α < 0.05 was set for all analyses. RESULTS All specimens successfully withstood the fatigue testing procedure, and no statistically significant differences in fracture strength were observed among the three groups (P > 0.05). The Fisher's exact test indicated a significant association between the restorative material and fracture type (F2 = 18.315, df = 2, P = 0.004), but also for repairability (F2 = 13.725, df = 2, P = 0.001). Crown-root fractures were significantly more common in the Cer_3 group compared to the Co_1 group (P = 0.001) and the Co_1 group had significantly more repairable fractures (F2 = 13.197, df = 2, P = 0.001). FEA revealed comparable outcomes of deformation among models and higher maximum tensile stress on models with higher frequency of catastrophic failures. CONCLUSIONS All tested restoration materials exhibited comparable fatigue survival and fracture strength in this laboratory and in silico study. However, it is important to recognize the potential for more severe and irreparable fractures when opting for deeply luted glass-ceramic inlay restorations in clinical practice. In such cases, it would be prudent to consider the alternative option being a direct composite approach, because of its more forgiving fracture types and repairability. CLINICAL IMPLICATIONS Molars with deep approximal direct and indirect restorations, whether with or without DME, are comparable in their fatigue survival and fracture resistance to withstand intra-oral forces. Deep direct restorations exhibit more repairable fractures compared to deeply luted glass-ceramics.
Collapse
Affiliation(s)
- Rijkje A Bresser
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands.
| | - Marco A Carvalho
- Dental School, Evangelical University of Goias, Anapolis, Brazil
| | - Lucas Z Naves
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands
| | - H Melma
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands
| | - Marco S Cune
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; St. Antonius Hospital Nieuwegein, Department of Oral Maxillofacial Surgery, Prosthodontics and Special Dental Care, Nieuwegein, the Netherlands
| | - Marco M M Gresnigt
- University of Groningen, University Medical Center Groningen, Center for Dentistry and Oral Hygiene, Department of Restorative Dentistry, Groningen, the Netherlands; Martini Hospital, Department of Special Dental Care, Groningen, the Netherlands
| |
Collapse
|
15
|
Chai H, Russ J, Vardhaman S, Lim C, Zhang Y. A Bilayer Method for Measuring Toughness and Strength of Dental Ceramics. J Dent Res 2024; 103:419-426. [PMID: 38410925 PMCID: PMC10966932 DOI: 10.1177/00220345231225445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024] Open
Abstract
The ever-increasing usage of ceramic materials in restorative dentistry necessitates a simple and effective method to evaluate flexural strength σF and fracture toughness KC. We propose a novel method to determine these quantities using a bilayer specimen composed of a brittle plate adhesively bonded onto a transparent polycarbonate substrate. When this bilayer structure is placed under spherical indentation, tunneling radial cracks initiate and propagate in the lower surface of the brittle layer. The failure analysis is based on previous theoretical relationships, which correlate σF with the indentation force P and layer thickness d, and KC with P and mean length of radial cracks. This work examines the accuracy and limitations of this approach using a wide range of contemporary dental ceramic materials. The effect of layer thickness, indenter radius, load level, and length and number of radial cracks are carefully examined. The accuracy of the predicted σF and KC is similar to those obtained with other concurrent test methods, such as biaxial flexure and 3-point bending (σF), and bending specimens with crack-initiation flaws (KC). The benefits of the present approach include treatment for small and thin plates, elimination of the need to introduce a precrack, and avoidance of dealing with local material nonlinearity effects for the KC measurements. Finally, the bilayer configuration resembles occlusal loading of a ceramic restoration (brittle layer) bonded to a posterior tooth (compliant substrate).
Collapse
Affiliation(s)
- H. Chai
- School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv, Israel
| | - J. Russ
- School of Dental Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - S. Vardhaman
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
- College of Dental Medicine, Columbia University, New York, NY, USA
| | - C.H. Lim
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| | - Y. Zhang
- Department of Preventive and Restorative Sciences, University of Pennsylvania, School of Dental Medicine, Philadelphia, PA, USA
| |
Collapse
|
16
|
Jin F, Yu X, Zhou H, Zhou J, Yang J, Luo Y, Chen Z. Fracture resistance of CAD/CAM endocrowns made from different materials in maxillary premolar interproximal defects. Clin Oral Investig 2024; 28:220. [PMID: 38492074 DOI: 10.1007/s00784-024-05605-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 03/08/2024] [Indexed: 03/18/2024]
Abstract
OBJECTIVES This in vitro study aims to compare the fracture resistance of three CAD/CAM materials used in endocrown restoration of interproximal defects in maxillary premolars. MATERIALS AND METHODS 45 maxillary premolars extracted as part of orthodontic treatment were included. Following standardized root canal treatment, all teeth were prepared into Mesial-Occlusal (MO) cavity types. The samples were then randomly divided into three groups: LD [repaired with lithium disilicate glass ceramics (IPS e.max CAD)], VE [treated with polymer-infiltrated ceramics (Vita Enamic)], and LU [repaired with resin-based nanoceramics (Lava Ultimate)]. Axial static loading was applied using a universal testing machine at 1 mm/min until fracture, and fracture resistance and failure modes were recorded. RESULTS Regarding Fracture Resistance Values (FRVs), the LD group exhibited significantly higher values than the other two groups, VE (P = 0.028) and LU (P = 0.005), which showed no significant difference (P = 0.778). On the other hand, regarding failure modes, the LD group had a higher prevalence of irreparable fractures compared to the other two groups, VE (P < 0.001) and LU (P < 0.001), which showed no significant difference. CONCLUSIONS Although lithium disilicate glass ceramics exhibited higher FRVs, they had a lower repair probability. In contrast, polymer-infiltrated ceramics and resin-based nanoceramics contributed to tooth structure preservation. CLINICAL RELEVANCE For maxillary premolars with interproximal defects following root canal treatment, resin ceramic composites are recommended for restoration to enhance abutment teeth protection.
Collapse
Affiliation(s)
- Fuqian Jin
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China
| | - Xiaoyan Yu
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China
| | - Haolin Zhou
- Zunyi Medical University Affiliated Stomatological Hospital, Zunyi, Guizhou, China
| | - Jin Zhou
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China
| | - Jing Yang
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China
| | - Yi Luo
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China.
| | - Zhu Chen
- Guiyang Hospital of Stomatology, Guiyang, Guizhou, China.
| |
Collapse
|
17
|
Al-Johani H, Alhotan A, Alhijji S, Silikas N, Satterthwaite J. Staining and bleaching susceptibility of zirconia-reinforced lithium silicate glass-ceramics with different thicknesses, translucencies, and fabrication methods. J Prosthet Dent 2024; 131:530.e1-530.e11. [PMID: 38262839 DOI: 10.1016/j.prosdent.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 01/05/2024] [Accepted: 01/08/2024] [Indexed: 01/25/2024]
Abstract
STATEMENT OF PROBLEM The influence of different thicknesses, translucencies, and fabrication methods on the spectrophotometric and topographical properties of zirconia-reinforced lithium silicate glass-ceramics (ZLSs) for dental restorations remains unclear. PURPOSE The purpose of this in vitro study was to investigate the effect of thicknesses, translucencies, and fabrication methods on the color stability, translucency parameter, opalescence parameter, whiteness stability, transmitted irradiance, light transmittance, opacity, gloss, and roughness of ZLSs exposed to coffee staining and bleaching treatments. MATERIAL AND METHODS Two pressable ZLSs (VITA AMBRIA, VA and Celtra Press, CP) and 2 machinable ZLSs (VITA Suprinity, VS and Celtra Duo, CD) were examined at high translucency (HT) and low translucency (LT) levels in 2 thicknesses (n=160). The specimens were evaluated at baseline, after coffee staining, and after bleaching. The color stability (ΔE2000), translucency parameter (TP), opalescence parameter (OP), whiteness index (WID), and whiteness stability (ΔWID) were measured with a spectrophotometer. Transmitted irradiance (It), light transmission (T), and opacity (O) were obtained from a light-polymerizing unit and a polymerization light collection device. Roughness stability (ΔSa%) was determined with an optical profilometer, and gloss stability (ΔGU%) was recorded with a gloss meter. Data of ΔCIE2000, ΔWID, ΔSa%, and ΔGU% were analyzed by 4-way ANOVA, and data of the TP, OP, WID, It, T, and O were analyzed by repeated 4-way ANOVA (α=.05). RESULTS VS-HT exceeded the ΔCIE2000 acceptability threshold after coffee staining and bleaching protocols. Pressable ZLSs exhibited greater color stability than machinable ZLSs. The 1-mm-thick VA, CP, and CD materials exceeded the ΔWID perceptibility threshold after bleaching. The highest TP and OP was displayed by the 1-mm-thick CP after bleaching. ΔGU increased after water storage and decreased after coffee staining and bleaching. ΔSa% significantly increased after bleaching (P<.05). CONCLUSIONS The color stability and other spectrophotometric properties of ZLSs depended on material thickness. The effects of ZLS fabrication methods and translucency levels on their measured properties were inconsistent. Subjecting 1-mm-thick ZLS materials to acidic media adversely impacted their stainability and surface texture.
Collapse
Affiliation(s)
- Hanan Al-Johani
- PhD student, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK.
| | - Abdulaziz Alhotan
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Saleh Alhijji
- Assistant Professor, Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Nick Silikas
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| | - Julian Satterthwaite
- Full Professor, Division of Dentistry, School of Medical Sciences, University of Manchester, Manchester, England, UK
| |
Collapse
|
18
|
Yamaguchi S, Li H, Sakai T, Lee C, Kitagawa H, Imazato S. CAD-CAM resin composites: Effective components for further development. Dent Mater 2024; 40:527-530. [PMID: 38228428 DOI: 10.1016/j.dental.2024.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/06/2024] [Accepted: 01/09/2024] [Indexed: 01/18/2024]
Abstract
OBJECTIVE This paper summarizes the effective components of computer-aided design and computer-aided manufacturing (CAD-CAM) resin composites that contribute to achieving greater mechanical properties and further development. METHODS In silico multi-scale analysis, in silico nonlinear dynamic finite element analysis (FEA), and artificial intelligence (AI) were used to explore the effective components of CAD-CAM resin composites. The effects of the filler diameter and silane coupling ratio on the mechanical properties of CAD-CAM resin composites have been clarified through multi-scale analysis. The effects of the filler contents, and filler and monomer compositions have been investigated by AI algorithms. The fracture behavior of CAD-CAM composite crown was analyzed using in silico non-linear dynamic FEA. The longevity of CAD-CAM composite crown was assessed through step-stress accelerating life testing (SSALT). RESULTS As the filler diameter decreases, there is an increase in elastic moduli and compressive strengths at the macroscale. At the nanoscale, a decrease in the filler diameter results in a decrease in the maximum value of the maximum principal strain. When the silane coupling ratio decreases, there is a decrease in the elastic modulus and compressive strength. According to the exhaustive search and feature importance analysis based on the AI algorithm, the combination of certain components was narrowed down to achieve a flexural strength of 269.5 MPa. The in silico non-linear FEA successfully detected the sign of the initial crack of the CAD-CAM composite molar crown. The SSALT revealed that CAD-CAM resin composite molar crowns containing nanofillers with a high fraction of resin matrix demonstrated great longevity. SIGNIFICANCE This paper summarized the effective components of CAD-CAM resin composites for their further development. The integration of in vitro and in silico approaches will expedite the advancement of CAD-CAM resin composites, offering benefits such as time efficiency and reduction of material waste for researchers and manufacturers.
Collapse
Affiliation(s)
- Satoshi Yamaguchi
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan.
| | - Hefei Li
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Takahiko Sakai
- Department of Fixed Prosthodontics and Orofacial Function, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Chunwoo Lee
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Haruaki Kitagawa
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Satoshi Imazato
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
19
|
Zhang T, Liu J, Qi J, Sun L, Liu X, Yan J, Zhang Y, Wu X, Li B. Biosafety and chemical solubility studies of multiscale crystal-reinforced lithium disilicate glass-ceramics. J Biomed Mater Res B Appl Biomater 2024; 112:e35400. [PMID: 38456343 DOI: 10.1002/jbm.b.35400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 02/20/2024] [Accepted: 02/25/2024] [Indexed: 03/09/2024]
Abstract
Lithium disilicate (Li2 Si2 O5 ) glass-ceramics are currently a more widely used all-ceramic restorative material due to their good mechanical properties and excellent aesthetic properties. However, they have a series of problems such as high brittleness and low fracture toughness, which has become the main bottleneck restricting its development. Therefore, in order to compensate for these shortcomings, we propose to prepare a reinforced glass-ceramics with better mechanical properties and to test the biosafety and chemical solubility of the material. Li2 Si2 O5 whiskers were synthesized by a one-step hydrothermal method, and multi-scale crystal-enhanced Li2 Si2 O5 glass-ceramics were prepared by reaction sintering. The biosafety of multi-scale crystal-reinforced Li2 Si2 O5 glass-ceramics was investigated by in vitro cytotoxicity test, rabbit pyrogen test, mice bone marrow micronucleus test, skin sensitization test, sub-chronic systemic toxicity test, and chronic systemic toxicity test. Additionally, the chemical solubility of multi-scale crystal-reinforced Li2 Si2 O5 glass-ceramics was investigated. The test results showed that the material was non-cytotoxic, non-thermogenic, non-mutagenic, non-sensitizing, and non-systemic. The chemical solubility, determined to be 377 ± 245 μg/cm2 , complied with the ISO 6872 standard for the maximum solubility of ceramic materials. Multi-scale crystal-reinforced Li2 Si2 O5 glass-ceramics' biosafety and chemical solubility met current normative criteria, and they can move on to mechanical property measurements (such as flexural strength test, fatigue life test, friction and wear property study, etc.) and bonding property optimization, which shows promise for future clinical applications.
Collapse
Affiliation(s)
- Tong Zhang
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Jinrong Liu
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Jin Qi
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Lingxiang Sun
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Xiaoming Liu
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Jingyu Yan
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Yanjie Zhang
- Research Institute of Photonics, Dalian Polytechnic University, Dalian, People's Republic of China
| | - Xiuping Wu
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| | - Bing Li
- School and Hospital of Stomatology, Shanxi Medical University, Taiyuan, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, China
| |
Collapse
|
20
|
Elmoselhy HAS, Hassanien OES, Haridy MF, Salam El Baz MAE, Saber S. Two‑year clinical performance of indirect restorations fabricated from CAD/CAM nano hybrid composite versus lithium disilicate in mutilated vital teeth. A randomized controlled trial. BMC Oral Health 2024; 24:101. [PMID: 38233771 PMCID: PMC10792922 DOI: 10.1186/s12903-023-03847-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 12/31/2023] [Indexed: 01/19/2024] Open
Abstract
TRIAL DESIGN This is a randomized, controlled, superiority, double-blinded, parallel-group, two-arms trial with an allocation ratio of 1:1. The aim of this trial was to compare the two-year clinical performance of partial indirect restorations fabricated from CAD/CAM nano-hybrid composite and ceramic lithium disilicate blocks using the modified USPHS criteria. METHODS In two parallel groups (n = 50 restorations), fifty participants having mutilated vital teeth with a minimum of two remaining walls were randomly enrolled in this trial and received indirect restorations of either nano-hybrid composite resin blocks (Brilliant, Coltene, Switzerland) or Lithium Disilicate (IPS Emax CAD). The restorations were assessed using modified USPHS criteria by two independent blinded assessors at baseline, six months, one-year and two years follow-up visits. Categorical and ordinal data were presented as frequencies and percentages. Categorical data were analyzed using the chi-square test. Ordinal data were analyzed using the Mann-Whitney U test for intergroup comparisons and Freidman's test followed by the Nemenyi post hoc test for intragroup comparisons. Numerical data were presented as mean and standard deviation values. They were analyzed for normality using the Shapiro-Wilk test. Data were found to be normally distributed and were analyzed using the independent t-test. The significance level was set at p ≤ 0.05 within all tests. RESULTS Forty-eight participants received the allocated intervention and completed the follow-up periods. There was a statistically significant difference between both tested materials for all USPHS criteria regarding Marginal integrity and Marginal discoloration at six-months Follow-up, but with no statistically significant difference at one- and two-year follow-up. CONCLUSIONS Both materials showed an acceptable, successful clinical performance along the two-years follow-up period. CLINICAL RELEVANCE The CAD/CAM nano-hybrid composite blocks are as reliable as Lithium disilicate for restoring mutilated vital teeth.
Collapse
Affiliation(s)
- Haneen Ahmad Shafik Elmoselhy
- Conservative Dentistry Department, Faculty of Dentistry, The British University in Egypt, Suez Desert Road El Sherouk City, Egypt
| | | | - Mohamed Fouad Haridy
- Conservative Dentistry, Faculty of Dentistry, Cairo University and The British University in Egypt, Suez Desert Road El Sherouk City, Egypt
| | | | - Shehabeldin Saber
- Endodontics, Faculty of Dentistry, Ain Shams University and The British University in Egypt, Suez Desert Road El Sherouk City, Egypt.
| |
Collapse
|
21
|
Liu X, Yao X, Zhang R, Sun L, Zhang Z, Zhao Y, Zhang T, Yan J, Zhang Y, Wu X, Li B. Recent advances in glass-ceramics: Performance and toughening mechanisms in restorative dentistry. J Biomed Mater Res B Appl Biomater 2024; 112:e35334. [PMID: 37776023 DOI: 10.1002/jbm.b.35334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Revised: 09/13/2023] [Accepted: 09/18/2023] [Indexed: 10/01/2023]
Abstract
The use of glass-ceramics in the medical field has grown significantly since the 1980s. With excellent aesthetic properties, semi-translucency, outstanding mechanical properties, corrosion resistance, wear resistance and great biocompatibility and workability glass-ceramics is one of the most commonly used materials in restorative dentistry and is widely used in veneers, inlays, onlays, all-ceramic crowns, and implant abutments. This review provides an overview of the research progress of glass-ceramics in restorative dentistry, focusing on the classification, performance requirements, toughening mechanisms and their association with clinical performance, as well as the manufacturing and fabrication of glass-ceramics in restorative dentistry. Finally, the developments and prospects of glass-ceramics in restorative dentistry are summarized and discussed.
Collapse
Affiliation(s)
- Xiaoming Liu
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Xuemin Yao
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Ran Zhang
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Lingxiang Sun
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Zheyuan Zhang
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Yifan Zhao
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Tong Zhang
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Jingyu Yan
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Yanjie Zhang
- Research Institute of Photonics, Dalian Polytechnic University, Dalian, Liaoning, China
| | - Xiuping Wu
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| | - Bing Li
- Shanxi Medical University School and Hospital of Stomatology, Taiyuan, Shanxi, China
- Shanxi Province Key Laboratory of Oral Diseases Prevention and New Materials, Taiyuan, Shanxi, China
| |
Collapse
|
22
|
Awad MM, Alhalabi F, Alanazi AA, Alanazi AA, Alshahrani GA, Fu C, Albaijan RS, Alkattan R, Fawzy AS. "No-Primer" Resin Cementation of Lithium Disilicate Ceramic: A Microtensile Bond Strength Evaluation. MATERIALS (BASEL, SWITZERLAND) 2023; 17:137. [PMID: 38203993 PMCID: PMC10779915 DOI: 10.3390/ma17010137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/18/2023] [Accepted: 12/22/2023] [Indexed: 01/12/2024]
Abstract
OBJECTIVE The objective of this study was to evaluate the resin-ceramic adhesion of a long-carbon-chain silane (LCSI)-containing resin cement. METHODS Polished lithium disilicate ceramic discs were etched with hydrofluoric acid and randomly assigned into four groups; (PSAP), cemented using a silane-free resin cement with no prior priming; (PSAP-S), primed using a silane-containing primer before cementation using a silane-free resin cement; (PSAU), cemented using a LCSI-containing resin cement with no prior priming; (PSAU-S), primed as for the group (PSAP-S) and cemented using a LCSI-containing resin cement. The cemented blocks were sectioned into microbeams. The resin-ceramic microtensile bond strength (μTBS) was measured at 1 week and after thermocycling. The failure modes of the tested microbeams were evaluated. RESULTS The μTBS of the LCSI-containing and silane-free resin cements, either with or without a prior priming step, did not significantly differ. The adhesion of the LCSI-containing resin cement to lithium disilicate ceramic, either with or without a prior priming step, did not significantly deteriorate after artificial aging. CONCLUSIONS The long-carbon-chain silane (LCSI) monomer incorporated in the resin cement eliminated the need for a silane priming step of a hydrofluoric acid-etched lithium disilicate ceramic.
Collapse
Affiliation(s)
- Mohamed M. Awad
- UWA Dental School, University of Western Australia, 17 Monash Avenue, Nedlands, WA 6009, Australia; (C.F.) (A.S.F.)
| | - Feras Alhalabi
- Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia
| | - Abdulaziz Abdullah Alanazi
- College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.A.A.); (A.A.A.); (G.A.A.)
| | - Abdulaziz Ali Alanazi
- College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.A.A.); (A.A.A.); (G.A.A.)
| | - Ghanem Abdullah Alshahrani
- College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia; (A.A.A.); (A.A.A.); (G.A.A.)
| | - Cheryl Fu
- UWA Dental School, University of Western Australia, 17 Monash Avenue, Nedlands, WA 6009, Australia; (C.F.) (A.S.F.)
| | - Refal Saad Albaijan
- Department of Prosthetic Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj 11942, Saudi Arabia;
| | - Rana Alkattan
- Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh 11545, Saudi Arabia;
- King Abdullah International Medical Research Center, Ministry of National Guard Health Affairs, Riyadh 11545, Saudi Arabia
| | - Amr S. Fawzy
- UWA Dental School, University of Western Australia, 17 Monash Avenue, Nedlands, WA 6009, Australia; (C.F.) (A.S.F.)
| |
Collapse
|
23
|
Jurado CA, Afrashtehfar KI, Hyer J, Alhotan A. Effect of sintering on the translucency of CAD-CAM lithium disilicate restorations: A comparative in vitro study. J Prosthodont 2023; 32:861-866. [PMID: 36609993 DOI: 10.1111/jopr.13644] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/29/2022] [Accepted: 01/03/2023] [Indexed: 01/09/2023] Open
Abstract
PURPOSE The available independent data on the translucency of novel pre and fully sintered chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate are limited. This comparative in vitro study evaluated the translucency degree of pre and fully sintered chairside CAD-CAM lithium disilicate crowns after optional, required, and additional firing processes. MATERIALS AND METHODS One hundred and five maxillary left central incisor crowns manufactured by three different CAD-CAM lithium disilicate brands shade A1 were assigned into seven groups as follows (n = 15): (1) Straumann n!ce without sintering; (2) Straumann n!ce with one additional sintering process; (3) Straumann n!ce with two additional sintering processes; (4) Amber Mill with one sintering process; (5) Amber Mill with two sintering processes; (6) IPS e.max CAD with one sintering process; and (7) IPS e.max CAD with two sintering processes. The translucency of all crowns was evaluated with a color imaging spectrophotometer. All statistical analyses were performed using statistical software. A standard level of significance was set at α < 0.05. RESULTS All the milled crowns presented different degrees of translucency, and additional sintering processes altered it. IPS e.max CAD with two (4.33 ± 0.26) and one (4.01 ± 0.15) sintering processes displayed the highest translucency, whereas Straumann n!ce with no sintering process provided the lowest value (2.82 ± 0.16). CONCLUSIONS The translucency of chairside lithium disilicate single-unit full-coverage restorations manufactured with subtractive technology was significantly influenced by the brand and the number of sintering processes. The traditional presintered IPS e.max CAD and the fully crystallized glass-ceramic Straumann n!ce considerably increased the translucency after one additional firing process, whereas Amber Mill decreased its translucency.
Collapse
Affiliation(s)
- Carlos A Jurado
- Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa, USA
| | - Kelvin I Afrashtehfar
- Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City, UAE
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Jared Hyer
- A.T. Still University Arizona School of Dentistry and Oral Health, Mesa, Arizona, USA
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
24
|
Diken Türksayar AA, Demirel M, Donmez MB. Optical properties, biaxial flexural strength, and reliability of new-generation lithium disilicate glass-ceramics after thermal cycling. J Prosthodont 2023; 32:815-820. [PMID: 36585789 DOI: 10.1111/jopr.13632] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/24/2022] [Accepted: 12/16/2022] [Indexed: 01/01/2023] Open
Abstract
PURPOSE To investigate the color stability, translucency, biaxial flexural strength (BFS), and reliability of nano-lithium disilicate and fully crystallized lithium disilicate after thermal cycling and to compare with those of a commonly used lithium disilicate. MATERIALS AND METHODS Three lithium disilicate glass-ceramics were used to prepare disk-shaped specimens (ø:12 mm, thickness: 1.2 mm) from A2 shaded HT blocks (Amber Mill, AM; Initial LiSi Block, IN; IPS e.max CAD, EX). AM and EX specimens were crystallized, and all specimens were polished with a polishing paste (Diamond Polish Mint). A spectrophotometer (CM-26d) was used to measure color coordinates before and after thermal cycling. BFS test was performed after thermal cycling. Color differences (ΔE00 ) and relative translucency parameter (RTP) values were calculated. One-way analysis of variance (ANOVA) (ΔE00 and BFS), two-way ANOVA followed by Tukey's HSD tests (RTP), and chi-square tests (Weibull modulus and characteristic strength) were used for the statistical analyses (α = 0.05). RESULTS No significant differences were observed among the ΔE00 values of tested materials (df = 2, F = 2.933, p = 0.070). RTP values were only affected by material type (p < 0.001) as AM had the highest RTP (p < 0.001), whereas IN and EX had similar values (p ≥ 0.165). BFS values varied among tested materials (df = 2, F = 21.341, p < 0.001). AM and EX had similar BFS values (p = 0.067) that were higher than that of IN (p ≤ 0.001). Weibull moduli of the materials were similar (p = 0.305), whereas EX had the highest and IN had the lowest characteristic strength values (p < 0.001) CONCLUSIONS: Although nano-lithium disilicate had the highest translucency, all materials had imperceptible color and translucency changes after thermal cycling when reported threshold values were considered. Newly introduced lithium disilicate glass-ceramics had adequate flexural strength as compared to the precursor material.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, İstanbul, Turkey
- ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Münir Demirel
- Oral and Dental Health, Vocational School, Biruni University, İstanbul, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
25
|
Tang T, Suputtamongkol K, Harnirattisai C, Neoh SP, Pongprueksa P. Interfacial fracture toughness of different surface treatments on zirconia-reinforced lithium silicate glass-ceramics. Dent Mater J 2023; 42:835-843. [PMID: 37880135 DOI: 10.4012/dmj.2023-124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2023]
Abstract
This study investigated the influence of different surface treatments on unfiring or firing zirconia-reinforced lithium silicate (ZLS) glass-ceramics. Celtra Duo and IPS e.max CAD blocks were cut and process following manufacturer protocols. The specimen surface was treated with seven different protocols. Two ceramic blocks with the same surface treatment were bonded with luting agent and prepared for mini-interfacial fracture toughness tests (mini-iFT). The specimens were tested after 1-week storage. The data was statistically analyzed using two-way ANOVA and Dunnett's T3 comparison (α=0.05). The highest mini-iFT of both Celtra Duo unfired and fired was shown in the HF+S group, which was not significantly different from HF+S+UA. For IPS e.max CAD, the mini-iFT was higher in the groups treated with hydrofluoric acid. Additional adhesive after silane application did not significantly improve bonding effectiveness. Therefore, surface treatment with hydrofluoric acid and silane is recommended for both unfiring and firing ZLS glass ceramics.
Collapse
Affiliation(s)
- Tianyu Tang
- Dental Biomaterials Science (International Programme), Faculty of Dentistry, Mahidol University
- School and Hospital of Stomatology, Kunming Medical University
| | | | | | - Siew Peng Neoh
- Department of Orthodontics, Faculty of Dentistry, Mahidol University
| | - Pong Pongprueksa
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University
| |
Collapse
|
26
|
Jurado CA, Arndt K, Azpiazu-Flores FX, Faddoul F, França R, Fischer NG, Watanabe H. Evaluation of Glazing and Polishing Systems for Novel Chairside CAD/CAM Lithium Disilicate and Virgilite Crowns. Oper Dent 2023; 48:689-699. [PMID: 37881035 DOI: 10.2341/23-017-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/06/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVE The purpose of this study was to evaluate the effectiveness of glazing, two zirconia, and two lithium disilicate polishing systems on surface roughness of a CAD/CAM lithium disilicate and virgilite ceramic with atomic force microscopy (AFM) and visual assessment performed by dental students and faculty. METHODS AND MATERIALS Sixty maxillary right central incisor crowns made of a novel chairside CAD/CAM lithium disilicate and virgilite (CEREC Tessera) were milled for glazing and polishing. The crowns were divided into six groups: no polishing/glazing provided (NoP/G); glazed (GZ); glazed and polished with Brasseler Dialite LD Lithium Disilicate (DiLD); glazed and polished with Meisinger Luster Lithium Disilicate (LuLD); glazed and polished with Brasseler Dialite ZR Zirconia (DiZR); and glazed and polished with Meisinger Luster Zirconia (LuZR). Surfaces were scanned with AFM to measure roughness (Ra) and root mean square roughness (Rq) and generate micrographs. Crowns were visually assessed by 10 dental students and 10 dental school faculty members to determine clinical acceptableness. RESULTS Glazing and all polishing kits significantly reduced Ra and Rq compared to no polishing/glazing. No significant Ra differences were found between glazing and all polishing kits (p>0.05). DiZR significantly reduced Rq compared to other groups (p<0.05). Visual assessment showed that GZ, LuLD, and DiZR were the most clinically acceptable crowns. CONCLUSION Polishing and glazing considerably improve the surface smoothness of maxillary central incisor crowns fabricated out of a chairside CAD/CAM lithium disilicate and virgilite ceramic. Altogether, zirconia polishing systems provided smoother and more clinically acceptable surfaces than the lithium disilicate kits.
Collapse
Affiliation(s)
- C A Jurado
- Carlos A Jurado, DDS, MS, associate professor, Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, Iowa, USA
| | - K Arndt
- Katlyn Arndt, BS, dental student, Texas Tech University Health Sciences Center El Paso, Woody L Hunt School of Dental Medicine, El Paso, Texas, USA
| | - F X Azpiazu-Flores
- Francisco X Azpiazu-Flores, DDS, MS, assistant professor, University of Manitoba, Gerald Niznick College of Dentistry, Winnipeg, Manitoba, Canada; ITI Scholar at the Implant Center and Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN, USA
| | - F Faddoul
- Fady Faddoul, DDS, MSD, associate dean, Clinical Affairs, Texas Tech University Health Sciences Center El Paso, Woody L Hunt School of Dental Medicine, El Paso, Texas, USA
| | - R França
- Rodrigo França, DDS, MS, PhD, associate professor, University of Manitoba, Gerald Niznick College of Dentistry, Winnipeg, Manitoba, Canada
| | - N G Fischer
- *Nicholas G Fischer, PhD, fellow, Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota School of Dentistry, Minneapolis, Minnesota, USA
| | - H Watanabe
- Hidehiko Watanabe, DDS, MS, professor, Department of Restorative Dentistry, Oregon Health and Sciences University School of Dentistry, Portland, Oregon, USA
| |
Collapse
|
27
|
Kobayashi M, Niizuma Y, Sugai R, Manabe A. Influence of the Crystallization Firing Process on Marginal and Internal Adaptation of Silicate-based Glass-ceramic Inlays Fabricated With a CAD/CAM Chairside System. Oper Dent 2023; 48:657-665. [PMID: 37882476 DOI: 10.2341/22-120-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVE Computer-aided design/computer-aided manufacturing (CAD/CAM) systems are widely used in dental treatment. Clinicians can use chairside CAD/CAM technology, which has the advantage of being able to fabricate inlays on the same day. We aimed to evaluate the effects of crystallization firing processes, fabrication methods (one-step and two-step), and materials on marginal and internal adaptations of silicate-based glass-ceramic all-ceramic inlays fabricated with CAD/CAM chairside systems. METHODS Ten artificial mandibular left first molars were prepared with standardized ceramic class II mesialocclusal (MO) inlay cavities. Optical impressions were obtained using CEREC Omnicam Ban. IPS e-max CAD (IE), (Ivoclar Vivadent, Schaan, Liechtenstein), Initial LiSi Block (LS) (Hongo, Bunkyoku, Tokyo, Japan), VITA Suprinity (SP), (Vita Zahnfabrick, Bad Säckingen, Germany), and Celtra Duo (CD) (Ivoclar Vivadent, Schaan, Liechtenstein) (n=10) were milled using CEREC MC XL (Bensheim, Germany). IE and SP were crystallization-fired using CEREC Speed Fire. The silicone replica technique was used for the measurement of internal (axial and pulpal walls) and marginal (cervical and occlusal edge) adaptations. The adaptations were measured using a thin layer of light-body polyvinyl siloxane impression material placed between the master tooth inlay preparation and restoration. Marginal and internal adaptations of IE, LS, SP, and CD were measured using a stereomicroscope (500×). For IE and SP, marginal and internal adaptations were measured before and after the crystallization firing process. Data analyses were conducted using one-way ANOVA and the Tukey test. For IE and SP, marginal and internal adaptations before and after the crystallization firing process were analyzed using the t-test. The significance level was set at α=0.05. RESULTS One-way ANOVA revealed statistically significant differences in occlusal and cervical edge marginal adaptations among the material groups (p<0.001). The Tukey HSD test revealed a significant difference in marginal occlusal and cervical edge adaptations between LS and CD groups and IE and SP groups (p≤0.05). For IE and SP inlays, the t-test revealed a significant difference between occlusal and cervical edge adaptations before the crystallization firing process and those after the crystallization firing process, with the latter group showing a more significant discrepancy in adaptation than the former group (p≤0.05). CONCLUSIONS Fabrication methods (one- and two-step) affected the marginal adaptation compatibility but not internal compatibility of MO inlays. The crystallization firing process affected the marginal adaptation of inlays using lithium silicate or lithium disilicate glass-ceramics. However, adaptation to the cavity was considered clinically acceptable for all materials.
Collapse
Affiliation(s)
- M Kobayashi
- *Mikihiro Kobayashi, DDS, PhD, Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, Tokyo, Japan
| | - Y Niizuma
- Yuiko Niizuma, DDS, PhD, Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, Tokyo, Japan
| | - R Sugai
- Rintaro Sugai, DDS, Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, Tokyo, Japan
| | - A Manabe
- Atsufumi Manabe, Department of Conservative Dentistry, Division of Aesthetic Dentistry and Clinical Cariology, Showa University School of Dentistry, Tokyo, Japan
| |
Collapse
|
28
|
Lu Y, de Oliveira Dal Piva AM, Tribst JPM, Feilzer AJ, Kleverlaan CJ. Does glaze firing affect the strength of advanced lithium disilicate after simulated defects? Clin Oral Investig 2023; 27:6429-6438. [PMID: 37726488 PMCID: PMC10630247 DOI: 10.1007/s00784-023-05246-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 09/05/2023] [Indexed: 09/21/2023]
Abstract
OBJECTIVE To study the influence of glazing on strength repair of lithium disilicate glass-ceramics after defect incorporation in different production processing phases. MATERIALS AND METHODS Bar-shaped specimens (1 × 1 × 12 mm, n = 280; 20/group) made from different lithium disilicate ceramics (IPS e.max CAD, Ivoclar, "LD" or advanced lithium disilicate CEREC Tessera, Dentsply Sirona, "ALD") were exposed to 7 different protocols: crystallized without (c) and with glaze layer (cg), with a defect incorporated before crystallization without (ic) and with glaze layer (icg), with a defect after crystallization without (ci) or with glaze layer (cig), and defect incorporated after the glaze layer (cgi). The flexural strength was determined using the three-point bending test. Analysis of indented areas and fractured specimens was performed by scanning electron microscopy. Flexural strength data were evaluated by two-way ANOVA followed by Tukey tests (α = 5%). RESULTS Two-way ANOVA revealed a significant influence of ceramic (p < 0.001; F = 55.45), protocol (p < 0.001; F = 56.94), and the interaction protocol*ceramic (p < 0.001; F = 13.86). Regardless of ceramics, defect incorporation as final step resulted in the worst strength, while defects introduced before crystallization did not reduce strength. Glaze firing after defect incorporation led to strength repair for ALD, whereas such an effect was not evident for LD. CONCLUSIONS The advanced lithium disilicate must receive a glaze layer to achieve its highest strength. Defects incorporated in the pre-crystallized stage can be healed during crystallization. Defects should not be incorporated after glazing. CLINICAL RELEVANCE Clinical adjustments should be performed on pre-crystallized or crystalized restorations that receive a glazer layer afterwards.
Collapse
Affiliation(s)
- Yuqing Lu
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, Noord-Holland, The Netherlands
| | - Amanda Maria de Oliveira Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, Noord-Holland, The Netherlands.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Albert J Feilzer
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, Noord-Holland, The Netherlands
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands
| | - Cornelis J Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit Van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan 3004, 1081 LA, Amsterdam, Noord-Holland, The Netherlands
| |
Collapse
|
29
|
Juri AZ, Song XF, Nakanishi Y, Dudley J, Jamieson L, Yin L. Surface fractures in pre-crystallized and crystallized zirconia-containing lithium silicate glass-ceramics generated in ultrasonic vibration-assisted machining. J Mech Behav Biomed Mater 2023; 147:106132. [PMID: 37776763 DOI: 10.1016/j.jmbbm.2023.106132] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 09/13/2023] [Accepted: 09/18/2023] [Indexed: 10/02/2023]
Abstract
Machining-induced surface fractures in ceramic restorations is a long-standing problem in dentistry, affecting the restorations' functionality and reliability. This study approached a novel ultrasonic vibration-assisted machining technique to zirconia-containing lithium silicate glass-ceramics (ZLS) and characterized its induced surface fracture topographies and morphologies to understand the microstructure-property-processing relations. The materials were processed using a digitally controlled ultrasonic milling machine at a harmonic vibration frequency with different amplitudes. Machining-induced surface fracture topographies were measured with a 3D white light optical profilometer using the arithmetic mean, peak and valley, and maximum heights, as well as the kurtosis and skewness height distributions, and the texture aspect ratios. Fracture morphologies were analysed using scanning electron microscopy (SEM). The surface fracture topographies were significantly dependent on the material microstructure, the mechanical properties, and the ultrasonic machining vibration amplitudes. Larger scale fractures with higher arithmetic mean, peak and valley heights, and kurtosis and skewness height distributions were induced in higher brittleness indexed pre-crystallized ZLS than lower indexed crystallized ZLS by conventional machining. Conchoidal fractures occurred in pre-crystallized ZLS while microcracks were found in crystallized state although brittle fractures mixed with localized ductile flow deformations dominated all machined ZLS surfaces. Ultrasonic machining at an ideal vibration amplitude resulted in more ductile removal, reducing fractured-induced peaks and valleys for both materials than conventional processing. This research demonstrates the microstructure-property-processing interdependence for ZLS materials and the novel machining technique to be superior to current processing, reducing fractures in the materials and potentially advancing dental CAD/CAM techniques.
Collapse
Affiliation(s)
- Afifah Z Juri
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia; Department of Mechanical and Manufacturing Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600, Bangi, Selangor, Malaysia
| | - Xiao-Fei Song
- Key Laboratory of Advanced Ceramics and Machining Technology of Ministry of Education, School of Mechanical Engineering, Tianjin University, Tianjin, 300354, China
| | - Yoshitaka Nakanishi
- Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto, 860-8555, Japan
| | - James Dudley
- Adelaide Dental School, The University of Adelaide, Adelaide, SA, 5005, Australia
| | - Lisa Jamieson
- Adelaide Dental School, The University of Adelaide, Adelaide, SA, 5005, Australia
| | - Ling Yin
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia.
| |
Collapse
|
30
|
Vichi A, Zhao Z, Mutahar M, Paolone G, Louca C. Translucency of Lithium-Based Silicate Glass-Ceramics Blocks for CAD/CAM Procedures: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:6441. [PMID: 37834578 PMCID: PMC10573117 DOI: 10.3390/ma16196441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/20/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
Amid chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) has been steadily increasing. This review aims to report on the translucency of these materials and the variables used to measure it. An electronic search was performed within the PubMed database within the period between 2 June 2011 and 11 September 2022. English-language papers investigating the translucency of IPS e.max CAD, Celtra Duo, Suprinity PC, Initial LiSi Block, Amber Mill, N!ce, and CEREC Tessera LSGC CAD/blocks were included in the search strategy. After an initial retrieval of 160 papers, the application of exclusion criteria, and the screening of abstracts and then of full texts, 33 papers were included in the study. The retrieved materials, with different degrees of translucency (LT, HT), were IPS e.max CAD (n = 33), Suprinity PC (n = 8), and Celtra Duo (n = 1). Concerning the examined colors, the most used was A2 (n = 20), followed by A1 (n = 8) and A3 (n = 2). The translucency parameter (TP) was the most used method (n = 30) with respect to the contrast ratio (CR) (n = 11) to assess translucency. Five papers measured both. Several specimens' thicknesses (0.5-4 mm) were investigated, with 1 mm (n = 23) being the most frequently analyzed. While a general tendency could be identified, conflicting results among different papers were reported.
Collapse
Affiliation(s)
- Alessandro Vichi
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Zejiao Zhao
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Mahdi Mutahar
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Chris Louca
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK (C.L.)
| |
Collapse
|
31
|
Al-Johani H, Haider J, Silikas N, Satterthwaite J. Effect of surface treatments on optical, topographical and mechanical properties of CAD/CAM reinforced lithium silicate glass ceramics. Dent Mater 2023; 39:779-789. [PMID: 37438204 DOI: 10.1016/j.dental.2023.07.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 06/21/2023] [Accepted: 07/04/2023] [Indexed: 07/14/2023]
Abstract
OBJECTIVES To investigate the effect of different surface treatments on optical, topographical and mechanical properties of CAD/CAM lithium silicate-based glass ceramics (LSC's) and their combined effect on the output of a light curing unit (LCU). METHODS Four CAD/CAM LSC's were investigated: Lithium Disilicate (Emax CAD; EC), Zirconia-reinforced silicates (Vita Suprinity; VS and Celtra Duo;CD) and Lithium Aluminum Disilicate (CEREC Tessera; CT). Ceramic specimens (n = 240) were divided into six subgroups according to their surface treatment: (a) Control, (b) Hydrofluoric acid (HF) 5%, (c) HF 5% + Neutralizing agent (N), (d) HF 9%, (e) HF 9% +N and (f) Self-etching ceramic primer (SEP). Irradiance, power and radiant exposure of a LCU were measured with MARC-LC following ceramic specimen interposition. Direct light transmission (T%) and absorbance (Abs%) of the specimens were measured with UV-Vis spectrophotometry. Roughness (Sa, Sq) and wettability (θ°) were measured with optical profilometry and sessile drop profile analysis, respectively. Biaxial flexural strength (σ) of the ceramic specimens was measured by the ball-on-three-balls method and ceramic specimens were examined microscopically. Statistical analyses was performed by two-way ANOVA followed by post hoc multiple comparisons (α = 0.05). RESULTS Acid neutralization decreased T% and increased Abs% in all LSC's and highest T% was exhibited with VS. Neutralized EC, VS and CD displayed higher Sa in HF9, while neutralized CT displayed higher Sa in HF5. Self-etch primer significantly reduced θ° (p < 0.001). σ was observed in the followed ascending order: HF9 +N < HF9 < HF5 +N < HF5 < SEP < Control for all LSC's. SIGNIFICANCE Optical, topographical and mechanical properties of the CAD/CAM ceramic blocks were strongly dependent on the type of surface treatment. Results of neutralization post-etching indicate promising potential for future investigations.
Collapse
Affiliation(s)
- Hanan Al-Johani
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Restorative Dentistry, Division of Biomaterials, Faculty of Dentistry, King Abdulaziz University, Saudi Arabia
| | - Julfikar Haider
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK; Department of Engineering, Manchester Metropolitan University, Manchester, United Kingdom
| | - Nick Silikas
- Division of Dentistry, School of Medical Sciences, University of Manchester, UK.
| | | |
Collapse
|
32
|
Lubauer J, Lohbauer U, Belli R. Fatigue Threshold R-Curves for Dental Lithium Disilicate Glass-Ceramics. J Dent Res 2023; 102:1106-1113. [PMID: 37448337 PMCID: PMC10467012 DOI: 10.1177/00220345231180565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/15/2023] Open
Abstract
Chemical and mechanical fatigue degradation in ceramic materials is generally inconspicuous yet ubiquitous, to the effect that clinical fractures still consist of the main cause of failure in all-ceramic restorations. Implications of this span wide, from a reduced survival prognosis for the affected teeth, including more frequent and increasingly invasive procedural interventions, to the financial burden borne by individuals and health care systems. To suffice as an effective corrective, restoration lifetimes need only to be extended so to outlive the patient. That opens a box of problems from a materials science standpoint, entailing inherent deficiencies of brittle materials to resist mechanical and environmental challenges. Efforts in developing more damage-tolerant and fatigue-resistant restoratives go thus hand in hand with understanding intrinsic mechanisms of crack growth behavior under conditions that simulate the oral environment. Here we developed experiments using size-relevant sharp precracked specimens with controlled size and geometry (truncated semielliptical crack in the surface-crack-in-biaxial-flexure method) to establish a relationship between crack size and strength. The tangent method was used to construct envelopes for the quasi-static resistance curves (R-curves), which served as template for deriving residual cyclic R-curve analogs. By means of experimentally obtained stress-cycle curves, lifetime and fatigue parameters were employed within a mechanistic framework to reveal constitutive toughening mechanisms during subcritical growth under cyclic loading in a wet environment. Using 3 modern dental lithium disilicate glass-ceramics, we demonstrate the extent of R-curve degradation up to a threshold of 10 million cycles (~30 y in service) and draw parallels between the scope of fatigue degradation and the size of the microstructural units responsible for toughening mechanisms in glass-ceramic materials. Our results indicate that larger microstructural elements endow glass-ceramics with a higher reaching quasi-static R-curve at the onset but degrading more rapidly to comparable levels of lithium disilicates having submicrometric and nanometric crystal phases.
Collapse
Affiliation(s)
- J. Lubauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1–Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Erlangen, Germany
| | - U. Lohbauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1–Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Erlangen, Germany
| | - R. Belli
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1–Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Erlangen, Germany
| |
Collapse
|
33
|
Munoz A, Zhao Z, Paolone G, Louca C, Vichi A. Flexural Strength of CAD/CAM Lithium-Based Silicate Glass-Ceramics: A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4398. [PMID: 37374581 DOI: 10.3390/ma16124398] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 06/01/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023]
Abstract
Amongst chairside CAD/CAM materials, the use of lithium-based silicate glass-ceramics (LSGC) for indirect restorations has recently been increasing. Flexural strength is one of the most important parameters to consider in the clinical selection of materials. The aim of this paper is to review the flexural strength of LSGC and the methods used to measure it. METHODS The electronic search was completed within PubMed database from 2 June 2011 to 2 June 2022. English-language papers investigating the flexural strength of IPS e.max CAD, Celtra Duo, Suprinity PC, and n!ce CAD/CAM blocks were included in the search strategy. RESULTS From 211 potential articles, a total of 26 were identified for a comprehensive analysis. Categorization per material was carried out as follows: IPS e.max CAD (n = 27), Suprinity PC (n = 8), Celtra Duo (n = 6), and n!ce (n = 1). The three-point bending test (3-PBT) was used in 18 articles, followed by biaxial flexural test (BFT) in 10 articles, with one of these using the four-point bending test (4-PBT) as well. The most common specimen dimension was 14 × 4 × 1.2 mm (plates) for the 3-PBT and 12 × 1.2 mm (discs) for BFT. The flexural strength values for LSGC materials varied widely between the studies. SIGNIFICANCE As new LSGC materials are launched on the market, clinicians need to be aware of their flexural strength differences, which could influence the clinical performance of restorations.
Collapse
Affiliation(s)
- Alvaro Munoz
- Faculty of Dentistry, University of Chile, Santiago 8380544, Chile
| | - Zejiao Zhao
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute University, 20132 Milan, Italy
| | - Chris Louca
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| | - Alessandro Vichi
- Dental Academy, University of Portsmouth, Portsmouth PO1 2QG, UK
| |
Collapse
|
34
|
Lu Y, Dal Piva AMO, Nedeljkovic I, Tribst JPM, Feilzer AJ, Kleverlaan CJ. Effect of glazing technique and firing on surface roughness and flexural strength of an advanced lithium disilicate. Clin Oral Investig 2023:10.1007/s00784-023-05014-1. [PMID: 37178172 DOI: 10.1007/s00784-023-05014-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 03/29/2023] [Indexed: 05/15/2023]
Abstract
OBJECTIVE The objective of this study was to investigate the effects of glazing technique and firing on the surface roughness and flexural strength of an advanced lithium disilicate (ALD) and lithium disilicate (LD). METHODS Eight groups of bar-shaped specimens (1 mm × 1 mm × 12 mm, N=160, 20/group) were manufactured from ALD (CEREC Tessera, Dentsply Sirona) and LD (IPS e.max CAD, Ivoclar). The specimens were then submitted to various posttreatments: crystallization (c), crystallization followed by a second firing (c-r), crystallization with glaze in one step (cg), and crystallization followed by a glaze layer firing (c-g). Surface roughness was measured by means of a profilometer, and flexural strength was determined using a three-point bending test. Surface morphology, fractography, and crack healing analysis were conducted using scanning electron microscopy. RESULTS Refiring (c-r) did not affect the surface roughness (Ra) while applying glaze at both cg and c-g procedures increased the roughness. ALDc-g (442.3 ± 92.5 MPa) promoted higher strength than ALDcg (282.1 ± 64.4 MPa), whereas LDcg (402.9 ± 78.4 MPa) was stronger than LDc-g (255.5 ± 68.7 MPa). Refiring completely closed the crack in ALD, but it had a limited effect on LD. CONCLUSIONS Two-step crystallization and glazing improved ALD strength compared to the one-step protocol. Refiring and one-step glazing do not increase LD's strength, while two-step glazing has a negative effect. CLINICAL RELEVANCE Besides both materials being lithium-disilicate glass ceramics, the glazing technique and firing protocol affected their roughness and flexural strength differently. A two-step crystallization and glazing should be the first choice for ALD, while for LD, glazing is optional and when necessary, should be applied in one-step.
Collapse
Affiliation(s)
- Y Lu
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
| | - A M O Dal Piva
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands.
| | - I Nedeljkovic
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
| | - J P M Tribst
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
| | - A J Feilzer
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
| | - C J Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, The Netherlands, Gustav Mahlerlaan 3004, 1081, Amsterdam, Noord-Holland, LA, Netherlands
| |
Collapse
|
35
|
Rauch A, Lorenz L, Reich S, Hahnel S, Schmutzler A, Schierz O. Long-term survival of monolithic tooth-supported lithium disilicate crowns fabricated using a chairside approach: 15-year results. Clin Oral Investig 2023:10.1007/s00784-023-05023-0. [PMID: 37083987 DOI: 10.1007/s00784-023-05023-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 04/11/2023] [Indexed: 04/22/2023]
Abstract
OBJECTIVES To investigate the clinical performance of chairside fabricated tooth-supported posterior single crowns from lithium disilicate ceramic. MATERIALS AND METHODS Thirty-four crowns (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) were inserted between 2006 and 2007 and again evaluated after 15 years. Survival and success rates were calculated according to Kaplan-Meier, and the quality of the crowns was evaluated by using modified United States Public Health (USPHS) criteria. RESULTS Twenty-two crowns were available for recall; six patients were defined as dropouts. The mean observation period was 15.2 years (± 0.2). Six failures occurred (1 technical/5 biological) resulting in a survival rate of 80.1%. The success rate was 64.2%. The roughness of the crowns increased (p = 0.021) and the majority of adhesive gaps were discolored (p = 0.001) in comparison to baseline. The color, tooth, and crown integrity remained stable over the follow-up period (p ≥ 0.317). CONCLUSION The fabrication of tooth-supported lithium disilicate crowns using a chairside approach yielded acceptable long-term survival and success rates. Due to discoloration, the long-term use of dual-cure self-adhesive resin cements might result in unpleasing esthetic results. CLINICAL RELEVANCE The performance of posterior lithium disilicate single crowns revealed excellent to good clinical quality and an acceptable number of events after 15 years of clinical service.
Collapse
Affiliation(s)
- Angelika Rauch
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany.
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany.
| | - Lea Lorenz
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany
| | - Sven Reich
- Department of Prosthodontics and Biomaterials, Centre of Implantology, Faculty of Medicine, RWTH University Hospital, Pauwellsstr. 30, 52074, Aachen, Germany
| | - Sebastian Hahnel
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Anne Schmutzler
- Department of Dental Prosthetics, University Hospital Regensburg, Franz-Josef-Strauß-Allee 11, 93053, Regensburg, Germany
| | - Oliver Schierz
- Department of Prosthodontics and Materials Science, University of Leipzig, Liebigstr. 12, 04103, Leipzig, Germany
| |
Collapse
|
36
|
Demirel M, Diken Türksayar AA, Donmez MB. Translucency, color stability, and biaxial flexural strength of advanced lithium disilicate ceramic after coffee thermocycling. J ESTHET RESTOR DENT 2023; 35:390-396. [PMID: 36057856 DOI: 10.1111/jerd.12960] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 08/12/2022] [Accepted: 08/13/2022] [Indexed: 10/14/2022]
Abstract
OBJECTIVE To compare the color stability, translucency, and biaxial flexural strength (BFS) of differently glazed advanced lithium disilicate (ALDS) with those of lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) after coffee thermocycling. MATERIALS AND METHODS Forty disk-shaped specimens were prepared from three lithium silicate based materials (CEREC Tessera, ALDS; IPS e.max CAD, LDS; Vita Suprinity, ZLS). ALDS specimens were divided into two subgroups according to glazing procedures (reduced glaze duration, ALDS-S and normal glaze duration, ALDS-N), while LDS and ZLS specimens were crystallized and glazed. Color coordinate measurements were performed before and after coffee thermocycling. Color differences (ΔE00 ) and relative translucency parameters (RTP) were calculated. Specimens were then subjected to BFS test. Statistical analysis was performed by using 1- (ΔE00 and BFS) and 2-way (RTP) ANOVA tests (α = 0.05). RESULTS ΔE00 values of tested materials were similar (df = 3, F = 0.150, p = 0.929). Two-way ANOVA showed the significant effect of material type, coffee thermocycling, and the interaction between these parameters on RTP values (p < 0.001). Both before and after thermocycling, LDS had the highest (p ≤ 0.001) and ZLS had the lowest (p < 0.001) RTP values, while ALDS-N had higher RTP than ALDS-S (p ≤ 0.001). Among tested materials, only LDS had similar RTP values before and after thermocycling (p = 0.865) as the other materials had lower RTP values after thermocycling (p < 0.001). ALDS-N had higher BFS values than ALDS-S (p = 0.005), while LDS had similar values to ALDS specimens (p ≥ 0.201). ZLS had the highest BFS (p ≤ 0.007). CONCLUSIONS ALDS had comparable values to those of other materials. However, reduced glazing duration resulted in decreased translucency and BFS of ALDS. CLINICAL SIGNIFICANCE ALDS may be an appropriate restorative material for those patients with increased coffee consumption considering its color stability and ability to maintain translucency, particularly when glazed by using a conventional porcelain furnace.
Collapse
Affiliation(s)
| | | | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, İstanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| |
Collapse
|
37
|
Abstract
The purpose of this article is to review current understanding of lithia-based glass-ceramics and to identify future research needs for this class of dental materials in relation to novel compositions and fabrication methods. With rapid advances in material development and digital technology, time efficiency of dental workflow and fit accuracy of ceramic restorations are ever improving. Lithia-based glass-ceramics are at the forefront of this advance-new variants with more efficient fabrication routes are continually being introduced into the marketplace. Base glass composition, crystallization heat treatment, nucleant and coloration additives, and property gradation are some pertinent variables. The trend in fabrication is to move from CAD/CAM grinding of partially crystallized glass-ceramics to fully crystallized materials, thereby circumventing the need for postmachining firing altogether. In these endeavors, a better understanding of mechanical properties and evolving shaping technologies, such as ductile grinding, is paramount. Additive manufacturing and 3-dimensional printing methodologies offer a promising alternative to current CAD/CAM subtractive manufacturing routes. Challenges to the implementation of new technologies in efficient development and production of high-quality dental glass-ceramic prostheses are addressed.
Collapse
Affiliation(s)
- Y. Zhang
- Department of Preventive and
Restorative Sciences, School of Dental Medicine, University of Pennsylvania,
Philadelphia, PA, USA
| | - S. Vardhaman
- Department of Preventive and
Restorative Sciences, School of Dental Medicine, University of Pennsylvania,
Philadelphia, PA, USA
| | - C.S. Rodrigues
- Department of Dental Materials and
Prosthodontics, Institute of Science and Technology, São Paulo State University, São
José dos Campos, Brazil
| | - B.R. Lawn
- Material Measurement Laboratory,
National Institute of Standards and Technology, Gaithersburg, MD, USA
| |
Collapse
|
38
|
Nano-to-microscale ductile-to-brittle transitions for edge cracking suppression in single-diamond grinding of lithium metasilicate/disilicate glass-ceramics. Ann Ital Chir 2022. [DOI: 10.1016/j.jeurceramsoc.2022.11.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
39
|
Jurado CA, Amarillas-Gastelum C, Afrashtehfar KI, Argueta-Figueroa L, Fischer NG, Alshabib A. Ceramic and Composite Polishing Systems for Milled Lithium Disilicate Restorative Materials: A 2D and 3D Comparative In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15155402. [PMID: 35955341 PMCID: PMC9369544 DOI: 10.3390/ma15155402] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 07/30/2022] [Accepted: 08/01/2022] [Indexed: 05/20/2023]
Abstract
Purpose: This study aims to evaluate the effectiveness of two ceramic and two composite polishing systems for a novel chairside computer-aided design/computer-aided manufacturing (CAD/CAM) lithium disilicate ceramic with three-dimensional and two-dimensional microscopy images. This ceramic material can be used for implant-supported or tooth-borne single-unit prostheses. Materials and Methods: Sixty flat samples of novel chairside CAD/CAM reinforced lithium disilicate ceramic (Amber Mill, Hass Bio) were divided into five groups (n = 15/group) and treated as follows: Group 1 (NoP), no polished treatment; group 2 (CeDi), polished with ceramic Dialite LD (Brasseler USA); group 3, (CeOp) polished with ceramic OptraFine (Ivoclar Vivadent); group 4, (CoDi) polished with composite DiaComp (Brasseler USA), and group 5 (CoAs), polished with composite Astropol (Ivoclar Vivadent). The polished ceramic surface topography was observed and measured with three-dimensional and two-dimensional images. Results: All polishing systems significantly reduced the surface roughness compared with the non-polished control group (Sa 1.15 μm). Group 2 (CeDi) provided the smoothest surface arithmetical mean eight with 0.32 μm, followed by group 3 (CeOp) with 0.34 μm. Group 5 (CoAs) with 0.52 μm provided the smoothest surface among the composite polishing kits. Group 4 (CoDi) with 0.66 μm provided the least smooth surface among all polishing systems tested. Conclusions: Despite the effectiveness of ceramic polishing systems being superior to composite polishing systems of the CAD/CAM lithium disilicate restorative material, both polishing systems significantly improved the smoothness.
Collapse
Affiliation(s)
- Carlos A. Jurado
- Woody L. Hunt School of Dental Medicine, Texas Tech University Health Sciences Center, El Paso, TX 79905, USA
| | | | - Kelvin I. Afrashtehfar
- Clinical Sciences Department, College of Dentistry, Ajman University, Ajman City P.O. Box 346, United Arab Emirates
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Berne, Switzerland
| | | | - Nicholas G. Fischer
- Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota School of Dentistry, Minneapolis, MN 55455, USA
| | - Abdulrahman Alshabib
- Department of Restorative Dentistry, King Saud University College of Dentistry, Riyadh 12372, Saudi Arabia
- Engineer Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, King Saud University, Riyadh 11545, Saudi Arabia
- Correspondence:
| |
Collapse
|
40
|
Hurle K, Lubauer J, Belli R, Lohbauer U. On the assignment of quartz-like LiAlSi 2O 6 - SiO 2 solid solutions in dental lithium silicate glass-ceramics: Virgilite, high quartz, low quartz or stuffed quartz derivatives? Dent Mater 2022; 38:1558-1563. [PMID: 35927096 DOI: 10.1016/j.dental.2022.07.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/22/2022] [Accepted: 07/25/2022] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Here we aim to provide a background on X-Ray Diffraction analysis of quartz-like crystal structures with varying amounts of Al3+ and Li+ substitution, existing confusions on their nomenclature and its implications for novel lithium silicate glass-ceramics. METHODS We reviewed the literature dealing with modifications of the quartz crystal structure and their stuffed LiAlSi2O6 derivates, LiAlSi2O6 - SiO2 solid solutions, the terminology of such phases and criteria used to define the structure known as virgilite. Based on this information, we attempted to allocate the quartz-like phases found in CEREC TesseraTM, InitialTM LiSi Block and Amber® Mill in the range of LiAlO2 - SiO2 solid solutions. For this purpose, their lattice parameters obtained from Rietveld refinement were compared with the lattice parameters of members of the corresponding solid solutions with defined SiO2 molar fraction found in the literature. RESULTS Based on the lattice parameters available for low quartz, high quartz and its stuffed derivatives, including LiAlSi2O6 and the mineral virgilite, a plot of the a- and c-parameters vs. the mol% SiO2 related to LiAlO2 was constructed with the literature data and the data found for the three dental lithium silicates. As per the definitions of virgilite as either LixAlxSi3-xO6, with 0.5 < x < 1 or especially as members of the LiAlSi2O6 - SiO2 solid-solution series with more than 50 mol% LiAlSi2O6, the crystal structures in CEREC TesseraTM, InitialTM LiSi Block and Amber® Mill failed to fall within the ranges of mol% SiO2 confined for virgilite. SIGNIFICANCE Based on available literature and definitions, the quartz-like phases found in the three dental lithium silicates should be addressed as stuffed (probably low) quartz solid solutions instead of "virgilite". However determined by mineralogical practices, the term "virgilite" for parts of the LiAlSi2O6 - SiO2 solid solution is ambiguous and can be considered as arbitrary.
Collapse
Affiliation(s)
- Katrin Hurle
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), GeoZentrum Nordbayern, Mineralogy, Schlossgarten 5a, 91054 Erlangen, Germany
| | - Julia Lubauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany
| | - Renan Belli
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany.
| | - Ulrich Lohbauer
- Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 - Zahnerhaltung und Parodontologie, Forschungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany
| |
Collapse
|
41
|
Soft machining-induced surface and edge chipping damage in pre-crystalized lithium silicate glass ceramics. J Mech Behav Biomed Mater 2022; 131:105224. [DOI: 10.1016/j.jmbbm.2022.105224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 03/28/2022] [Accepted: 04/02/2022] [Indexed: 11/19/2022]
|
42
|
Load-to-Failure Resistance and Optical Characteristics of Nano-Lithium Disilicate Ceramic after Different Aging Processes. MATERIALS 2022; 15:ma15114011. [PMID: 35683309 PMCID: PMC9182075 DOI: 10.3390/ma15114011] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Revised: 06/02/2022] [Accepted: 06/02/2022] [Indexed: 01/27/2023]
Abstract
The aim of this study was to compare the load-to-failure resistance and optical properties of nano-lithium disilicate (NLD) with lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) in different aging processes. Thirty crowns were milled from NLD, LDS, and ZLS (n = 10). All crowns were subjected to thermomechanical aging and loaded until catastrophic failure. Ten specimens from each material were prepared in two different thicknesses (0.7 mm and 1.5 mm, n = 5), and color coordinates were measured before and after coffee thermocycling. Color differences (ΔE00) and relative translucency parameter (RTP) were calculated. Data were analyzed by using ANOVA and Bonferroni-corrected t-tests (α = 0.05). ZLS had the highest load-to-failure resistance (p ≤ 0.002), while the difference between LDS and NLD was nonsignificant (p = 0.776). The interaction between material type and thickness affected ΔE00 (p < 0.001). Among the 0.7 mm thick specimens, ZLS had the lowest ΔE00 (p < 0.001). Furthermore, 1.5 mm thick ZLS had lower ΔE00 than that of 1.5 mm thick LDS (p = 0.036). Other than ZLS (p = 0.078), 0.7 mm thick specimens had higher ΔE00 (p < 0.001). The interaction between material type, thickness, and thermocycling affected RTP (p < 0.001). Thinner specimens presented higher RTP (p < 0.001). NLD and LDS had higher RTP than ZLS (p ≤ 0.036). However, 0.7 mm thick specimens had similar RTP after coffee thermocycling (p ≥ 0.265). Coffee thermocycling reduced the RTP values of 0.7 mm thick NLD (p = 0.032) and LDS (p = 0.008). NLD may endure the occlusal forces present in the posterior region. However, long-term coffee consumption may impair the esthetics of restorations particularly when thin NLD is used.
Collapse
|
43
|
Sabino SDRF, Cordeiro BGB, Silva LD, Pukasiewicz AG, Zanotto ED, Serbena FC. Microstructural and residual stress effects on toughening of stoichiometric BaO.2SiO2 glass-ceramics. Ann Ital Chir 2022. [DOI: 10.1016/j.jeurceramsoc.2022.05.073] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Abstract
Ceramic materials have rapidly become the material of choice for indirect restorations. There are a variety of material types available for use such as feldspathic ceramics, glass ceramics and many types of zirconia. Advances in digital dentistry led to a rapid switch from porcelain fused to metal restorations to all-ceramic restorations. Variations in composition, microstructure and processing affect mechanical properties and use of these materials. Having a better understanding of their differences is important for proper clinical selection. Ceramic materials may be classified several ways including by composition, microstructure, processing technique and clinical application. This article reviews the various types of ceramics based on structure and properties that relate to clinical selection. After reading this article, the reader should be able to: explain the types of ceramics in use in dentistry; understand clinical selection based on properties; and discuss the differences in zirconia-based ceramics.
Collapse
|
45
|
A split-Chevron-Notched-Beam sandwich specimen for fracture toughness testing of bonded interfaces. J Mech Behav Biomed Mater 2022; 131:105236. [DOI: 10.1016/j.jmbbm.2022.105236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 04/06/2022] [Accepted: 04/10/2022] [Indexed: 11/22/2022]
|