1
|
Wang H, Zhao Q, Li D, Zhang Z, Liu Y, Guo X, Li X, Liu Z, Wang L, Ma J, He H. Boosting Photothermocatalytic Oxidation of Toluene Over Pt/N-TiO 2: The Gear Effect of Light and Heat. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:7662-7671. [PMID: 38578018 DOI: 10.1021/acs.est.3c10459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
Photothermal catalysis is extremely promising for the removal of various indoor pollutants owing to its photothermal synergistic effect, while the low light utilization efficiency and unclear catalytic synergistic mechanism hinder its practical applications. Here, nitrogen atoms are introduced, and Pt nanoparticles are loaded on TiO2 to construct Pt/N-TiO2-H2, which exhibits 3.5-fold higher toluene conversion rate than the pure TiO2. Compared to both photocatalytic and thermocatalytic processes, Pt/N-TiO2-H2 exhibited remarkable performance and stability in the photothermocatalytic oxidation of toluene, achieving 98.4% conversion and 98.3% CO2 yield under a light intensity of 260 mW cm-2. Furthermore, Pt/N-TiO2-H2 demonstrated potential practical applicability in the photothermocatalytic elimination of various indoor volatile organic compounds. The synergistic effect occurs as thermocatalysis accelerates the accumulation of carboxylate species and the degradation of aldehyde species, while photocatalysis promotes the generation of aldehyde species and the consumption of carboxylate species. This ultimately enhances the photothermocatalytic process. The photothermal synergistic effect involves the specific conversion of intermediates through the interplay of light and heat, providing novel insights for the design of photothermocatalytic materials and the understanding of photothermal mechanisms.
Collapse
Affiliation(s)
- Huihui Wang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Qian Zhao
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Daiqiang Li
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Zhilin Zhang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Criminology, People's Public Security University of China, Beijing 100038, China
| | - Yuan Liu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xueli Guo
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- Ganjiang Innovation Academy, Chinese Academy of Sciences, Ganzhou 341000, China
| | - Xiaotong Li
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Zhi Liu
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Lian Wang
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jinzhu Ma
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hong He
- State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
2
|
Ongwandee M, Khianthongkul K, Panyametheekul S, Yongprapat K, Srinaka K, Morris J. Bangkok school indoor air quality: monitoring and intervention by positive pressure fresh air system. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:25454-25467. [PMID: 38472572 DOI: 10.1007/s11356-024-32843-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/29/2024] [Indexed: 03/14/2024]
Abstract
A PM2.5 crisis in Thailand has caused the Thai government and public to be increasingly concerned about children's exposure to PM2.5 during time in school. This study is a part of a project to create a modeled effective school indoor air quality management for the Bangkok Metropolitan Administration (BMA). We measured air quality and environment in 10 Bangkok school rooms, including CO2, CO, O3, PM2.5, PM10, TVOCPID, formaldehyde, airborne bacteria and fungi, and gaseous organic contaminants. The indoor-to-outdoor concentration ratios indicated that either outdoor sources or indoor + outdoor sources were the predominant contributors to PM in naturally ventilated classrooms. Meanwhile, PM levels in air-conditioned classrooms strongly depended on class activities. CO2 measurements showed that the air-conditioned classrooms had a low 0.4 per hour air change rate and total fungal counts also reached 800 CFU m-3. Analysis of gaseous organic compounds showed that the two most abundant were aliphatic and aromatic hydrocarbons, accounting for 60% by mass concentration. Interestingly, 2-ethyl-1-hexanol, a mucous membrane irritant, was detected in all study rooms. In one naturally ventilated classroom, we implemented a positive pressure fresh air system to mitigate in-class PM levels; it kept PM levels below 20 μg m-3 throughout the class day. Students reported a 20-37% increase in satisfaction with the perceived indoor environmental quality and reported reduced rates in all symptoms of the sick building syndrome after implementing the positive pressure system.
Collapse
Affiliation(s)
- Maneerat Ongwandee
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand.
- HAUS IAQ Research Unit, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
| | | | - Sirima Panyametheekul
- HAUS IAQ Research Unit, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University King Chulalongkorn Memorial Hospital, Bangkok, Thailand
- Department of Environmental Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand
| | - Kamomchai Yongprapat
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand
| | - Kessara Srinaka
- Institute of Metropolitan Development, Navamindradhiraj University, Bangkok, Thailand
| | - John Morris
- School of Industrial Education and Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok, Thailand
| |
Collapse
|
3
|
Ballesteros Álvarez J, Romero Barriuso A, Villena Escribano B, Rodríguez Sáiz A, González-Gaya C. Investigating the effectiveness of a new indoor ventilation model in reducing the spread of disease: A case of sports centres amid the COVID-19 pandemic. Heliyon 2024; 10:e27877. [PMID: 38560668 PMCID: PMC10979208 DOI: 10.1016/j.heliyon.2024.e27877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2023] [Revised: 03/01/2024] [Accepted: 03/07/2024] [Indexed: 04/04/2024] Open
Abstract
The ventilation of buildings is crucial to ensure indoor health, especially when demanding physical activities are carried out indoors, and the pandemic has highlighted the need to develop new management methods to ensure adequate ventilation. In Spain, there are no specific ventilation regulations to prevent the spread of pathogens such as the coronavirus. Therefore, it is necessary to have a theoretical tool for calculating occupancy to maintain sports facilities in optimal safety conditions. The proposed theoretical method is based on the analysis of mathematical expressions from European standardisation documents and uses the concentration of CO2 as a bioeffluent. It is also based on the concept of background and critical concentration, which allows its application to be extrapolated to future crises caused by pathogens. This study presents a unique and novel dataset for sports centres. For this purpose, the calculation methods were applied to the data set provided by Mostoles City Council, Spain, during the pandemic years with the highest incidence of COVID-19, when the government introduced the assimilation of COVID-19 sick leave to occupational accidents. The data on this type of sick leave provided by the City Council correspond to the period between March 2020 and February 2022. Similarly, the data on the average use of sports facilities by activity, provided by the Sports Department, correspond to the years 2020 and 2021. In this way, it was possible to verify the effectiveness in preventing the spread of any type of coronavirus. In conclusion, the implementation of a theoretical occupancy calculation method based on the concentration of carbon dioxide as a bioeffluent can be an effective tool for the management of future crises caused by pathogens or hazardous chemicals in the air, and demonstrated its effectiveness in sports centres such as gyms, sports fields, and indoor swimming pools during the COVID-19 pandemic.
Collapse
Affiliation(s)
- J.M. Ballesteros Álvarez
- Department of Architectural Constructions & Construction and Land Engineering, University of Burgos, Burgos, Spain
| | | | - B.M. Villena Escribano
- Departmet of Construction and Manufacturing Engineering, Universidad Nacional de Educación a Distancia, Madrid, Spain
| | - A. Rodríguez Sáiz
- Department of Architectural Constructions & Construction and Land Engineering, University of Burgos, Burgos, Spain
| | - C. González-Gaya
- Departmet of Construction and Manufacturing Engineering, Universidad Nacional de Educación a Distancia, Madrid, Spain
| |
Collapse
|
4
|
Chawla H, Anand P, Garg K, Bhagat N, Varmani SG, Bansal T, McBain AJ, Marwah RG. A comprehensive review of microbial contamination in the indoor environment: sources, sampling, health risks, and mitigation strategies. Front Public Health 2023; 11:1285393. [PMID: 38074709 PMCID: PMC10701447 DOI: 10.3389/fpubh.2023.1285393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 10/25/2023] [Indexed: 12/18/2023] Open
Abstract
The quality of the indoor environment significantly impacts human health and productivity, especially given the amount of time individuals spend indoors globally. While chemical pollutants have been a focus of indoor air quality research, microbial contaminants also have a significant bearing on indoor air quality. This review provides a comprehensive overview of microbial contamination in built environments, covering sources, sampling strategies, and analysis methods. Microbial contamination has various origins, including human occupants, pets, and the outdoor environment. Sampling strategies for indoor microbial contamination include air, surface, and dust sampling, and various analysis methods are used to assess microbial diversity and complexity in indoor environments. The review also discusses the health risks associated with microbial contaminants, including bacteria, fungi, and viruses, and their products in indoor air, highlighting the need for evidence-based studies that can relate to specific health conditions. The importance of indoor air quality is emphasized from the perspective of the COVID-19 pandemic. A section of the review highlights the knowledge gap related to microbiological burden in indoor environments in developing countries, using India as a representative example. Finally, potential mitigation strategies to improve microbiological indoor air quality are briefly reviewed.
Collapse
Affiliation(s)
- Hitikk Chawla
- Institute for Cell Biology and Neuroscience, Goethe University Frankfurt, Frankfurt, Germany
| | - Purnima Anand
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Kritika Garg
- Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, India
| | - Neeru Bhagat
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Shivani G. Varmani
- Department of Biomedical Science, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Tanu Bansal
- Department of Biochemistry, All India Institute of Medical Sciences, New Delhi, India
| | - Andrew J. McBain
- School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Ruchi Gulati Marwah
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| |
Collapse
|
5
|
Hama S, Kumar P, Tiwari A, Wang Y, Linden PF. The underpinning factors affecting the classroom air quality, thermal comfort and ventilation in 30 classrooms of primary schools in London. ENVIRONMENTAL RESEARCH 2023; 236:116863. [PMID: 37567379 DOI: 10.1016/j.envres.2023.116863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 08/04/2023] [Accepted: 08/08/2023] [Indexed: 08/13/2023]
Abstract
The health and academic performance of children are significantly impacted by air quality in classrooms. However, there is a lack of understanding of the relationship between classroom air pollutants and contextual factors such as physical characteristics of the classroom, ventilation and occupancy. We monitored concentrations of particulate matter (PM), CO2 and thermal comfort (relative humidity and temperature) across five schools in London. Results were compared between occupied and unoccupied hours to assess the impact of occupants and their activities, different floor coverings and the locations of the classrooms. In-classroom CO2 concentrations varied between 500 and 1500 ppm during occupancy; average CO2 (955 ± 365 ppm) during occupancy was ∼150% higher than non-occupancy. Average PM10 (23 ± 15 μgm-3), PM2.5 (10 ± 4 μgm-3) and PM1 (6 ± 3 μg m-3) during the occupancy were 230, 125 and 120% higher than non-occupancy. Average RH (29 ± 6%) was below the 40-60% comfort range in all classrooms. Average temperature (24 ± 2 °C) was >23 °C in 60% of classrooms. Reduction in PM10 concentration (50%) by dual ventilation (mechanical + natural) was higher than for PM2.5 (40%) and PM1 (33%) compared with natural ventilation (door + window). PM10 was higher in classrooms with wooden (33 ± 19 μg m-3) and vinyl (25 ± 20 μgm-3) floors compared with carpet (17 ± 12 μgm-3). Air change rate (ACH) and CO2 did not vary appreciably between the different floor levels and types. PM2.5/PM10 was influenced by different occupancy periods; highest value (∼0.87) was during non-occupancy compared with occupancy (∼0.56). Classrooms located on the ground floor had PM2.5/PM10 > 0.5, indicating an outdoor PM2.5 ingress compared with those located on the first and third floors (<0.5). The large-volume (>300 m3) classroom showed ∼33% lower ACH compared with small-volume (100-200 m3). These findings provide guidance for taking appropriate measures to improve classroom air quality.
Collapse
Affiliation(s)
- Sarkawt Hama
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, United Kingdom; Department of Chemistry, School of Science, University of Sulaimani, Sulaimani, Kurdistan Region, Iraq
| | - Prashant Kumar
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, United Kingdom; Institute for Sustainability, University of Surrey, Guildford, GU2 7XH, Surrey, United Kingdom.
| | - Arvind Tiwari
- Global Centre for Clean Air Research (GCARE), School of Sustainability, Civil and Environmental Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH, United Kingdom
| | - Yan Wang
- UCL Institute for Environmental Design and Engineering, London, United Kingdom
| | - Paul F Linden
- Department of Applied Mathematics and Theoretical Physics, Centre for Mathematical Sciences, Wilberforce Road, Cambridge, CB3 0WA, United Kingdom
| |
Collapse
|
6
|
Dos Santos UR, Dos Santos JL. Trichoderma after crossing kingdoms: infections in human populations. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART B, CRITICAL REVIEWS 2023; 26:97-126. [PMID: 36748123 DOI: 10.1080/10937404.2023.2172498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Trichoderma is a saprophytic fungus that is used worldwide as a biocontrol and biofertilizer agent. Although considered nonpathogenic until recently, reports of human infections produced by members of the Trichoderma genus are increasing. Numerous sources of infection were proposed based upon patient data and phylogenetic analysis, including air, agriculture, and healthcare facilities, but the deficit of knowledge concerning Trichoderma infections makes patient treatment difficult. These issues are compounded by isolates that present profiles which exhibit high minimum inhibitory concentration values to available antifungal drugs. The aim of this review is to present the global distribution and sources of infections that affect both immunocompetent and immunocompromised hosts, clinical features, therapeutic strategies that are used to treat patients, as well as highlighting treatments with the best responses. In addition, the antifungal susceptibility profiles of Trichoderma isolates that have emerged in recent decades were examined and which antifungal drugs need to be further evaluated as potential candidates to treat Trichoderma infections are also indicated.
Collapse
Affiliation(s)
- Uener Ribeiro Dos Santos
- Immunobiology Laboratory, Department of Biological Science, State University of Santa Cruz, Ilhéus, BA, Brazil
| | - Jane Lima Dos Santos
- Immunobiology Laboratory, Department of Biological Science, State University of Santa Cruz, Ilhéus, BA, Brazil
| |
Collapse
|
7
|
Li H, Liu PQ, Luo QP, Ma JJ, Yang XR, Yan Y, Su JQ, Zhu YG. Spatiotemporal variations of microbial assembly, interaction, and potential risk in urban dust. ENVIRONMENT INTERNATIONAL 2022; 170:107577. [PMID: 36244231 DOI: 10.1016/j.envint.2022.107577] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 10/08/2022] [Accepted: 10/08/2022] [Indexed: 06/16/2023]
Abstract
Community and composition of dust-borne microbes would affect human health and are regulated by microbial community assembly. The dust in kindergarten is always collected to evaluate the microbial exposure of children, yet the microbial assembly, their interactions, and potential pathogens in kindergarten dust remain unclear. Here, we aim to investigate the microbial community assembly and structures, and potential bacterial pathogens in outdoor dust of kindergartens, and reveal the factors influencing the assembly and composition of microbial community. A total of 118 urban dust samples were collected on the outdoor impervious surfaces of 59 kindergartens from different districts of Xiamen in January and June 2020. We extracted microbial genomic DNA in these dusts and characterized the microbial (i.e., bacteria and fungi) community compositions and diversities using target gene-based (16S rRNA genes for bacterial community and ITS 2 regions for fungal community) high-throughput sequencing. Potential bacterial pathogens were identified and the interactions between microbes were determined through a co-occurrence network analysis. Our results showed the predominance of Actinobacteria and α-Proteobacteria in bacterial communities and Capnodiales in fungal communities. Season altered microbial assembly, composition, and interactions, with both bacterial and fungal communities exhibiting a higher heterogeneity in summer than those in winter. Although stochastic processes predominated in bacterial and fungal community assembly, the season-depended environmental factors (e.g., temperature) and interactions between microbes play important roles in dust microbial community assembly. Potential bacterial pathogens were detected in all urban dust, with significantly higher relative abundance in summer than that in winter. These results indicated that season exerted more profound effects on microbial community composition, assembly, and interactions, and suggested the seasonal changes of potential risk of microbes in urban dust. Our findings provide new insights into microbial community, community assembly, and interactions between microbes in the urban dust, and indicate that taxa containing opportunistic pathogens occur commonly in urban dust.
Collapse
Affiliation(s)
- Hu Li
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; Zhejiang Key Laboratory of Urban Environmental Processes and Pollution Control, CAS Haixi Industrial Technology Innovation Center in Beilun, Ningbo 315830, Peoples R China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Pei-Qin Liu
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Qiu-Ping Luo
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Jin-Jin Ma
- Department of Environmental Science and Engineering, Huaqiao University, Xiamen 361021, China
| | - Xiao-Ru Yang
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; Zhejiang Key Laboratory of Urban Environmental Processes and Pollution Control, CAS Haixi Industrial Technology Innovation Center in Beilun, Ningbo 315830, Peoples R China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Yu Yan
- Department of Environmental Science and Engineering, Huaqiao University, Xiamen 361021, China.
| | - Jian-Qiang Su
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; Zhejiang Key Laboratory of Urban Environmental Processes and Pollution Control, CAS Haixi Industrial Technology Innovation Center in Beilun, Ningbo 315830, Peoples R China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Yong-Guan Zhu
- Key Laboratory of Urban Environment and Health, Ningbo Observation and Research Station, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; Zhejiang Key Laboratory of Urban Environmental Processes and Pollution Control, CAS Haixi Industrial Technology Innovation Center in Beilun, Ningbo 315830, Peoples R China; University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| |
Collapse
|
8
|
Rodríguez D, Urbieta IR, Velasco Á, Campano-Laborda MÁ, Jiménez E. Assessment of indoor air quality and risk of COVID-19 infection in Spanish secondary school and university classrooms. BUILDING AND ENVIRONMENT 2022; 226:109717. [PMID: 36313012 PMCID: PMC9595429 DOI: 10.1016/j.buildenv.2022.109717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/14/2022] [Accepted: 10/15/2022] [Indexed: 06/16/2023]
Abstract
Despite the risk of transmission of SARS-CoV-2, Spanish educational centers were reopened after six months of lockdown. Ventilation was mostly adopted as a preventive measure to reduce the transmission risk of the virus. However, it could also affect indoor air quality (IAQ). Therefore, here we evaluate the ventilation conditions, COVID-19 risk, and IAQ in secondary school and university classrooms in Toledo (central Spain) from November 2020 to June 2021. Ventilation was examined by monitoring outdoor and indoor CO2 levels. CO2, occupancy and hygrothermal parameters, allowed estimating the relative transmission risk of SARS-CoV-2 (Alpha and Omicron BA.1), H r, under different scenarios, using the web app COVID Risk airborne . Additionally, the effect of ventilation on IAQ was evaluated by measuring indoor/outdoor (I/O) concentration ratios of O3, NO2, and suspended particulate matter (PM). University classrooms, particularly the mechanically ventilated one, presented better ventilation conditions than the secondary school classrooms, as well as better thermal comfort conditions. The estimated H r for COVID-19 ranged from intermediate (with surgical masks) to high (no masks, teacher infected). IAQ was generally good in all classrooms, particularly at the university ones, with I/O below unity, implying an outdoor origin of gaseous pollutants, while the source of PM was heterogeneous. Consequently, controlled mechanical ventilation systems are essential in educational spaces, as well as wearing well-fitting FFP2-N95 masks indoors is also highly recommended to minimize the transmission risk of COVID-19 and other airborne infectious diseases.
Collapse
Affiliation(s)
- Diana Rodríguez
- Departamento de Química Física, Facultad de Ciencias Ambientales y Bioquímica, Universidad de Castilla-La Mancha (UCLM), Avenida Carlos III s/n, 45071, Toledo, Spain
| | - Itziar R Urbieta
- Departamento de Ciencias Ambientales, Facultad de Ciencias Ambientales y Bioquímica, UCLM, Avenida Carlos III s/n, 45071, Toledo, Spain
| | - Ángel Velasco
- Departamento de Ciencias Ambientales, Facultad de Ciencias Ambientales y Bioquímica, UCLM, Avenida Carlos III s/n, 45071, Toledo, Spain
| | - Miguel Ángel Campano-Laborda
- Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, 41012, Sevilla, Spain
| | - Elena Jiménez
- Departamento de Química Física, Facultad de Ciencias y Tecnologías Químicas, UCLM, Avda. Camilo José Cela 1B, 13071, Ciudad Real, Spain
| |
Collapse
|
9
|
Haug H, Klein L, Sauerwald T, Poelke B, Beauchamp J, Roloff A. Sampling Volatile Organic Compound Emissions from Consumer Products: A Review. Crit Rev Anal Chem 2022:1-22. [PMID: 36306209 DOI: 10.1080/10408347.2022.2136484] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Volatile organic compounds (VOCs) are common constituents of many consumer products. Although many VOCs are generally considered harmless at low concentrations, some compound classes represent substances of concern in relation to human (inhalation) exposure and can elicit adverse health effects, especially when concentrations build up, such as in indoor settings. Determining VOC emissions from consumer products, such as toys, utensils or decorative articles, is of utmost importance to enable the assessment of inhalation exposure under real-world scenarios with respect to consumer safety. Due to the diverse sizes and shapes of such products, as well as their differing uses, a one-size-fits-all approach for measuring VOC emissions is not possible, thus, sampling procedures must be chosen carefully to best suit the sample under investigation. This review outlines the different sampling approaches for characterizing VOC emissions from consumer products, including headspace and emission test chamber methods. The advantages and disadvantages of each sampling technique are discussed in relation to their time and cost efficiency, as well as their suitability to realistically assess VOC inhalation exposures.
Collapse
Affiliation(s)
- Helen Haug
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
- Department of Chemistry and Pharmacy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Chair of Aroma and Smell Research, Erlangen, Germany
| | - Luise Klein
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Tilman Sauerwald
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
| | - Birte Poelke
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| | - Jonathan Beauchamp
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Freising, Germany
| | - Alexander Roloff
- Department of Chemical and Product Safety, German Federal Institute for Risk Assessment (BfR), Berlin, Germany
| |
Collapse
|
10
|
Leite ADS, Rousse S, Léon J, Trindade RIF, Haoues‐Jouve S, Carvallo C, Dias‐Alves M, Proietti A, Nardin E, Macouin M. Barking up the Right Tree: Using Tree Bark to Track Airborne Particles in School Environment and Link Science to Society. GEOHEALTH 2022; 6:e2022GH000633. [PMID: 36089983 PMCID: PMC9432803 DOI: 10.1029/2022gh000633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 07/13/2022] [Accepted: 07/26/2022] [Indexed: 06/15/2023]
Abstract
Children's exposure to air pollution affects both their health and learning skills. Fine and ultrafine particulate matter (PM2.5, PM1), notably issued from traffic sources in urban centers, belong to the most potential harmful health hazards. However their monitoring and the society's awareness on their dangers need to be consolidated. In this study, raising teacher and pupil involvement for air quality improvement in their schools environment is reached through developing a passive monitoring technique (bio-sensors made of tree bark). The experiment was implemented in two urban elementary schools situated close to a main traffic road of the city of Toulouse (South of France). Magnetic properties, carbonaceous fraction measurements, and scanning electronic microscopy (SEM-EDX) investigations were realized both on passive bio-sensors and filters issued from active sampling. We find that traffic is the main PM1 source for both outdoors and indoors at schools. Higher levels of outdoor PM in the school's environments compared to urban background are reached especially in the cold period. The schools proximity to a main traffic source and lack of ventilation are the main causes for observed PM1 accumulation in classrooms. The co-working experiment with educational teams and pupils shows that the use of bio-sensors is a driver for children empowerment to air pollution and therefore represents a potential key tool for the teachers though limiting eco-anxiety. As PM accumulation is observed in many scholar environments across Europe, the proposed methodology is a step toward a better assessment of PM impact on pupil's health and learning skills.
Collapse
Affiliation(s)
- A. d. S. Leite
- Géosciences Environnement ToulouseCNRSIRDUniversité Toulouse 3CNESToulouseFrance
| | - S. Rousse
- Géosciences Environnement ToulouseCNRSIRDUniversité Toulouse 3CNESToulouseFrance
| | - J.‐F. Léon
- Laboratoire d’AérologieCNRSUniversité Toulouse 3ToulouseFrance
| | - R. I. F. Trindade
- Departamento de GeofísicaInstituto de Astronomia, Geofísica e Ciências AtmosféricasUniversidade de São PauloSão PauloBrazil
| | - S. Haoues‐Jouve
- Laboratoire Interdisciplinaire Solidarités Sociétés TerritoiresCNRSUniversité Toulouse 2EHESSENSFEAToulouseFrance
| | - C. Carvallo
- Institut de Minéralogie, de Physique des Matériaux et de CosmochimieUMR 7590Sorbonne UniversitéParisFrance
| | - M. Dias‐Alves
- Laboratoire d’AérologieCNRSUniversité Toulouse 3ToulouseFrance
| | - A. Proietti
- Centre de Microcaractérisation Raimond CastaingUniversité Toulouse 3ToulouseFrance
| | - E. Nardin
- Géosciences Environnement ToulouseCNRSIRDUniversité Toulouse 3CNESToulouseFrance
| | - M. Macouin
- Géosciences Environnement ToulouseCNRSIRDUniversité Toulouse 3CNESToulouseFrance
| |
Collapse
|
11
|
Li GX, Duan YY, Wang Y, Bian LJ, Xiong MR, Song WP, Zhang X, Li B, Dai YL, Lu JW, Li M, Liu ZG, Liu SG, Zhang L, Yao HJ, Shao RG, Li L. Potential urinary biomarkers in young adults with short-term exposure to particulate matter and bioaerosols identified using an unbiased metabolomic approach. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 305:119308. [PMID: 35443204 DOI: 10.1016/j.envpol.2022.119308] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 03/29/2022] [Accepted: 04/12/2022] [Indexed: 06/14/2023]
Abstract
Numerous epidemiological studies have shown a close relationship between outdoor air pollution and increased risks for cancer, infection, and cardiopulmonary diseases. However, very few studies have investigated the potential health effects of coexposure to airborne particulate matter (PM) and bioaerosols through the transmission of infectious agents, particularly under the current circumstances of the coronavirus disease 2019 pandemic. In this study, we aimed to identify urinary metabolite biomarkers that might serve as clinically predictive or diagnostic standards for relevant diseases in a real-time manner. We performed an unbiased gas/liquid chromatography-mass spectroscopy (GC/LC-MS) approach to detect urinary metabolites in 92 samples from young healthy individuals collected at three different time points after exposure to clean air, polluted ambient, or purified air, as well as two additional time points after air repollution or repurification. Subsequently, we compared the metabolomic profiles between the two time points using an integrated analysis, along with Kyoto Encyclopedia of Genes and Genomes-enriched pathway and time-series analysis. We identified 33 and 155 differential metabolites (DMs) associated with PM and bioaerosol exposure using GC/LC-MS and follow-up analyses, respectively. Our findings suggest that 16-dehydroprogesterone and 4-hydroxyphenylethanol in urine samples may serve as potential biomarkers to predict or diagnose PM- or bioaerosol-related diseases, respectively. The results indicated apparent differences between PM- and bioaerosol-associated DMs at five different time points and revealed dynamic alterations in the urinary metabolic profiles of young healthy humans with cyclic exposure to clean and polluted air environments. Our findings will help in investigating the detrimental health effects of short-term coexposure to airborne PM and bioaerosols in a real-time manner and improve clinically predictive or diagnostic strategies for preventing air pollution-related diseases.
Collapse
Affiliation(s)
- Guang-Xi Li
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Yuan-Yuan Duan
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Yi Wang
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Ling-Jie Bian
- Dongzhimen Hospital, Beijing University of Chinese Medicine, No.116 Cuiping Street, Tongzhou District, Beijing, 100010, China.
| | - Meng-Ran Xiong
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Wen-Pin Song
- Key Laboratory of Antibiotic Bioengineering of National Health and Family Planning Commission (NHFPC), Institute of Medicinal Biotechnology (IMB), Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), NO.1 Tiantan Xili, Beijing, 100050, China.
| | - Xia Zhang
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Biao Li
- Shanghai Lu Ming Biological Technology Co. Ltd., Shanghai, 100037, China.
| | - Yu-Long Dai
- Shanghai Lu Ming Biological Technology Co. Ltd., Shanghai, 100037, China.
| | - Jia-Wei Lu
- Shanghai Lu Ming Biological Technology Co. Ltd., Shanghai, 100037, China.
| | - Meng Li
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Zhi-Guo Liu
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Shi-Gang Liu
- Guang'anmen Hospital, Chinese Academy of Chinese Medical Sciences, No.5 BeiXianGe St, XiCheng District, Beijing, 100053, China.
| | - Li Zhang
- Key Laboratory of Antibiotic Bioengineering of National Health and Family Planning Commission (NHFPC), Institute of Medicinal Biotechnology (IMB), Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), NO.1 Tiantan Xili, Beijing, 100050, China.
| | - Hong-Juan Yao
- Key Laboratory of Antibiotic Bioengineering of National Health and Family Planning Commission (NHFPC), Institute of Medicinal Biotechnology (IMB), Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), NO.1 Tiantan Xili, Beijing, 100050, China.
| | - Rong-Guang Shao
- Key Laboratory of Antibiotic Bioengineering of National Health and Family Planning Commission (NHFPC), Institute of Medicinal Biotechnology (IMB), Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), NO.1 Tiantan Xili, Beijing, 100050, China.
| | - Liang Li
- Key Laboratory of Antibiotic Bioengineering of National Health and Family Planning Commission (NHFPC), Institute of Medicinal Biotechnology (IMB), Chinese Academy of Medical Sciences and Peking Union Medical College (CAMS & PUMC), NO.1 Tiantan Xili, Beijing, 100050, China.
| |
Collapse
|
12
|
Vaali K, Tuomela M, Mannerström M, Heinonen T, Tuuminen T. Toxic Indoor Air Is a Potential Risk of Causing Immuno Suppression and Morbidity—A Pilot Study. J Fungi (Basel) 2022; 8:jof8020104. [PMID: 35205859 PMCID: PMC8877819 DOI: 10.3390/jof8020104] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 12/28/2021] [Accepted: 01/04/2022] [Indexed: 02/01/2023] Open
Abstract
We aimed to establish an etiology-based connection between the symptoms experienced by the occupants of a workplace and the presence in the building of toxic dampness microbiota. The occupants (5/6) underwent a medical examination and urine samples (2/6) were analyzed by LC-MS/MS for mycotoxins at two time-points. The magnitude of inhaled water was estimated. Building-derived bacteria and fungi were identified and assessed for toxicity. Separate cytotoxicity tests using human THP-1 macrophages were performed from the office’s indoor air water condensates. Office-derived indoor water samples (n = 4/4) were toxic to human THP-1 macrophages. Penicillium, Acremonium sensu lato, Aspergillus ochraceus group and Aspergillus section Aspergillus grew from the building material samples. These colonies were toxic in boar sperm tests (n = 11/32); four were toxic to BHK-21 cells. Mycophenolic acid, which is a potential immunosuppressant, was detected in the initial and follow-up urine samples of (2/2) office workers who did not take immunosuppressive drugs. Their urinary mycotoxin profiles differed from household and unrelated controls. Our study suggests that the presence of mycotoxins in indoor air is linked to the morbidity of the occupants. The cytotoxicity test of the indoor air condensate is a promising tool for risk assessment in moisture-damaged buildings.
Collapse
Affiliation(s)
- Kirsi Vaali
- SelexLab Oy, Kalevankatu 17 A, 00100 Helsinki, Finland
- Correspondence: ; Tel.: +358-50-550-1131
| | - Marja Tuomela
- Co-op Bionautit, Viikinkaari 9, 00790 Helsinki, Finland;
- Department of Microbiology, University of Helsinki, 00014 Helsinki, Finland
| | - Marika Mannerström
- The Finnish Centre for Alternative Methods, Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön katu 34, 33014 Tampere, Finland; (M.M.); (T.H.)
| | - Tuula Heinonen
- The Finnish Centre for Alternative Methods, Faculty of Medicine and Health Technology, Tampere University, Arvo Ylpön katu 34, 33014 Tampere, Finland; (M.M.); (T.H.)
| | - Tamara Tuuminen
- Medical Center Kruunuhaka Oy, Kaisaniemenkatu 8B a, 00100 Helsinki, Finland;
| |
Collapse
|
13
|
The Toxicity of Wiped Dust and Airborne Microbes in Individual Classrooms Increase the Risk of Teachers' Work-Related Symptoms: A Cross-Sectional Study. Pathogens 2021; 10:pathogens10111360. [PMID: 34832514 PMCID: PMC8624243 DOI: 10.3390/pathogens10111360] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 10/06/2021] [Accepted: 10/12/2021] [Indexed: 12/23/2022] Open
Abstract
Background: The causes and pathophysiological mechanisms of building-related symptoms (BRS) remain open. Objective: We aimed to investigate the association between teachers’ individual work-related symptoms and intrinsic in vitro toxicity in classrooms. This is a further analysis of a previously published dataset. Methods: Teachers from 15 Finnish schools in Helsinki responded to the symptom survey. The boar sperm motility inhibition assay, a sensitive indicator of mitochondrial dysfunction, was used to measure the toxicity of wiped dust and cultured microbial fallout samples collected from the teachers’ classrooms. Results: 231 teachers whose classroom toxicity data had been collected responded to the questionnaire. Logistic regression analysis adjusted for age, gender, smoking, and atopy showed that classroom dust intrinsic toxicity was statistically significantly associated with the following 12 symptoms reported by teachers (adjusted ORs in parentheses): nose stuffiness (4.1), runny nose (6.9), hoarseness (6.4), globus sensation (9.0), throat mucus (7.6), throat itching (4.4), shortness of breath (12.2), dry cough (4.7), wet eyes (12.7), hypersensitivity to sound (7.9), difficulty falling asleep (7.6), and increased need for sleep (7.7). Toxicity of cultured microbes was found to be associated with nine symptoms (adjusted ORs in parentheses): headache (2.3), nose stuffiness (2.2), nose dryness (2.2), mouth dryness (2.8), hoarseness (2.2), sore throat (2.8), throat mucus (2.3), eye discharge (10.2), and increased need for sleep (3.5). Conclusions: The toxicity of classroom dust and airborne microbes in boar sperm motility inhibition assay significantly increased teachers’ risk of work-related respiratory and ocular symptoms. Potential pathophysiological mechanisms of BRS are discussed.
Collapse
|
14
|
Chaetomium and Chaetomium-like Species from European Indoor Environments Include Dichotomopilus finlandicus sp. nov. Pathogens 2021; 10:pathogens10091133. [PMID: 34578165 PMCID: PMC8466430 DOI: 10.3390/pathogens10091133] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 08/25/2021] [Accepted: 09/01/2021] [Indexed: 11/17/2022] Open
Abstract
The genus Chaetomium is a frequently occurring fungal taxon world-wide. Chaetomium and Chaetomium-like species occur in indoor environments, where they can degrade cellulose-based building materials, thereby causing structural damage. Furthermore, several species of this genus may also cause adverse effects on human health. The aims of this research were to identify Chaetomium and Chaetomium-like strains isolated from indoor environments in Hungary and Finland, two geographically distant regions of Europe with drier and wetter continental climates, respectively, and to study their morphological and physiological properties, as well as their extracellular enzyme activities, thereby comparing the Chaetomium and Chaetomium-like species isolated from these two different regions of Europe and their properties. Chaetomium and Chaetomium-like strains were isolated from flats and offices in Hungary, as well as from schools, flats, and offices in Finland. Fragments of the translation elongation factor 1α (tef1α), the second largest subunit of RNA polymerase II (rpb2) and β-tubulin (tub2) genes, as well as the internal transcribed spacer (ITS) region of the ribosomal RNA gene cluster were sequenced, and phylogenetic analysis of the sequences performed. Morphological examinations were performed by stereomicroscopy and scanning electron microscopy. Thirty-one Chaetomium sp. strains (15 from Hungary and 16 from Finland) were examined during the study. The most abundant species was Ch. globosum in both countries. In Hungary, 13 strains were identified as Ch. globosum, 1 as Ch. cochliodes, and 1 as Ch. interruptum. In Finland, 10 strains were Ch. globosum, 2 strains were Ch. cochliodes, 2 were Ch. rectangulare, and 2 isolates (SZMC 26527, SZMC 26529) proved to be representatives of a yet undescribed phylogenetic species from the closely related genus Dichotomopilus, which we formally describe here as the new species Dichotomopilus finlandicus. Growth of the isolates was examined at different temperatures (4, 15, 20, 25, 30, 37, 35, 40, and 45 °C), while their extracellular enzyme production was determined spectrophotometrically.
Collapse
|
15
|
Bayati M, Vu DC, Vo PH, Rogers E, Park J, Ho TL, Davis AN, Gulseven Z, Carlo G, Palermo F, McElroy JA, Nagel SC, Lin CH. Health risk assessment of volatile organic compounds at daycare facilities. INDOOR AIR 2021; 31:977-988. [PMID: 33586827 DOI: 10.1111/ina.12801] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2020] [Accepted: 01/30/2021] [Indexed: 06/12/2023]
Abstract
Children are particularly vulnerable to many classes of the volatile organic compounds (VOCs) detected in indoor environments. The negative health impacts associated with chronic and acute exposures of the VOCs might lead to health issues such as genetic damage, cancer, and disorder of nervous systems. In this study, 40 VOCs including aldehydes and ketones, aliphatic hydrocarbons, esters, aromatic hydrocarbons, cyclic terpenes, alcohols, and glycol ethers were identified and qualified in different locations at the University of Missouri (MU) Child Development Laboratory (CDL) in Columbia, Missouri. Our results suggested that the concentrations of the VOCs varied significantly among classrooms, hallways, and playground. The VOCs emitted from personal care and cleaning products had the highest indoor levels (2-ethylhexanol-1, 3-carene, homomenthyl salicylate with mean concentration of 5.15 µg/m3 , 1.57 µg/m3 , and 1.47 µg/m3 , respectively). A cancer risk assessment was conducted, and none of the 95th percentile dose estimates exceeded the age-specific no significant risk levels (NSRL) in all classrooms. Dimensionless toxicity index scores were calculated for all VOCs using a novel web-based framework called Toxicological Prioritization Index (ToxPi), which integrates multiple sources of toxicity data. According to the method, homomenthyl salicylate, benzothiazole, 2-ethylhexyl salicylate, hexadecane, and tridecane exhibited diverse toxicity profiles and ranked as the five most toxic indoor VOCs. The findings of this study provide critical information for policy makers and early education professionals to mitigate the potentially negative health impacts of indoor VOCs in the childcare facilities.
Collapse
Affiliation(s)
- Mohamed Bayati
- Center for Agroforestry, University of Missouri, Columbia, MO, USA
- Department of Environmental Engineering, Tikrit University, Tikrit, Iraq
- Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO, USA
| | - Danh C Vu
- Faculty of Technology, Van Lang University, Ho Chi Minh City, Vietnam
| | - Phuc H Vo
- Center for Agroforestry, University of Missouri, Columbia, MO, USA
| | - Elizabeth Rogers
- Center for Agroforestry, University of Missouri, Columbia, MO, USA
- School of Natural Resources, University of Missouri, Columbia, MO, USA
| | - Jihyun Park
- Center for Agroforestry, University of Missouri, Columbia, MO, USA
- School of Natural Resources, University of Missouri, Columbia, MO, USA
| | - Thi L Ho
- Center of Core Facilities, Cuu Long Delta Rice Research Institute, Can Tho, Vietnam
| | - Alexandra N Davis
- Department of Individual, Family, and Community Education, University of New Mexico, Albuquerque, NM, USA
| | - Zehra Gulseven
- School of Education, University of California Irvine, Irvine, CA, USA
| | - Gustavo Carlo
- School of Education, University of California Irvine, Irvine, CA, USA
| | - Francisco Palermo
- Department of Human Development and Family Science, Center for Children and Families Across Cultures, University of Missouri, Columbia, MO, USA
| | - Jane A McElroy
- Department of Family and Community Medicine, University of Missouri, Columbia, MO, USA
| | - Susan C Nagel
- Department of Obstetrics, Gynecology and Women's Health, School of Medicine, University of Missouri, Columbia, MO, USA
| | - Chung-Ho Lin
- Center for Agroforestry, University of Missouri, Columbia, MO, USA
- School of Natural Resources, University of Missouri, Columbia, MO, USA
| |
Collapse
|