1
|
Elfellaki N, Berrouch S, Biary A, Goïta S, Rafi H, Lachkar H, Dehhani O, Rougemont AD, Bourlet T, Hafid JE. Comparison of four concentration methods of adenovirus, norovirus and rotavirus in tap water. J Virol Methods 2024; 330:115013. [PMID: 39209160 DOI: 10.1016/j.jviromet.2024.115013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Revised: 08/20/2024] [Accepted: 08/26/2024] [Indexed: 09/04/2024]
Abstract
Human enteric viruses, as adenovirus (HAdV), norovirus (HuNoV) and rotavirus (RVA) are significant causes of gastroenteritis associated with consumption of contaminated water worldwide. Various methods have been described for their detection and monitoring in water. The aim of this study was to compare the performance of four conditions for concentrating HAdV, HuNoV and RVA from water matrices, in order to develop a single protocol that could simultaneously concentrate all target viruses from tap water. The tested conditions were based on the adsorption-elution using electronegative filters, in which we evaluated cation-coated filtration by MgCl2 with or without acid rinse by H2SO4 and two elution buffers, namely NaOH and tris-glycine-beef extract. Genomic material was extracted and amplified by real-time PCR and real-time RT-PCR using commercial kits. Based on the statistical analysis of amplification results (cycles of quantification), the condition involving cation-coated filtration by MgCl2 using electronegative filters with acid rinse by H2SO4 combined with NaOH elution allowed efficient recovery of both HAdV, HuNoV and RVA from tap water compared to the other conditions. These findings confirm the effectiveness of the approach used to monitor three major enteric viruses in tap water.
Collapse
Affiliation(s)
- Nouhaila Elfellaki
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Salma Berrouch
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco; Higher School of Technology of El Kelâa des Sraghna, Cadi Ayyad University, El Kelâa des Sraghna, Morocco
| | - Abdelkader Biary
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Simeon Goïta
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Houda Rafi
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Hibatallah Lachkar
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Oussama Dehhani
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco
| | - Alexis de Rougemont
- National Reference Centre for Gastroenteritis Viruses, Laboratory of Virology, University Hospital of Dijon Bourgogne, France
| | - Thomas Bourlet
- Infectious Agents and Hygiene Department, University Hospital of Saint Etienne, Saint-Etienne, France
| | - Jamal Eddine Hafid
- Laboratory of Bioresources and Food Safety, Faculty of Sciences and Technology, Cadi Ayyad University, Marrakech, Morocco.
| |
Collapse
|
2
|
Pérez-Cataluña A, Randazzo W, Martínez-Blanch JF, Codoñer FM, Sánchez G. Sample and library preparation approaches for the analysis of the virome of irrigation water. JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE 2023; 103:4450-4457. [PMID: 36823282 DOI: 10.1002/jsfa.12522] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 02/14/2023] [Accepted: 02/23/2023] [Indexed: 06/06/2023]
Abstract
BACKGROUND The virome (i.e. community of mainly RNA and DNA eukaryotic viruses and bacteriophages) of waters is yet to be extensively explored. In particular, the virome of waters used for irrigation could therefore potentially carry viral pathogens that can contaminate fresh produce. One problem in obtaining viral sequences from irrigation waters is the relatively low amount of virus particles, as well as the presence of human, bacterial and protozoan cells. The present aimed study was to compare different processing, amplification, and sequencing approaches for virome characterization in irrigation waters. RESULTS Our analyses considered percentages of viral reads, values for diversity indices and number of families found in sequencing results. The results obtained suggest that enrichment protocols using two (bezonase and microccocal nuclease) or four enzymes at once (bezonase, microccocal nuclease, DNAse and RNase), regardless of an Amicon filtration step, are more appropriate than separated enzymatic treatments for virome characterization in irrigation water. The NetoVIR protocol combined with the ScriptSeq v2 RNA-Seq Library (P0-L20 protocol) showed the highest percentages of RNA viruses and identified the higher number of families. CONCLUSION Although virome characterization applied in irrigation waters is an important tool for protecting public health by informing on circulating human and zoonotic infections, optimized and standardized procedures should be followed to reduce the variability of results related to either the sample itself and the downstream bioinformatics analyses. Our results show that virome characterization can be an important tool in the discovery of pathogenic viruses in the environment and can be used to inform and optimize reference-based detection methods provided that appropriate and rigorous controls are included. © 2023 The Authors. Journal of The Science of Food and Agriculture published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
Collapse
Affiliation(s)
- Alba Pérez-Cataluña
- Department of Preservation and Food Safety Technologies, IATA-CSIC, Valencia, Spain
| | - Walter Randazzo
- Department of Preservation and Food Safety Technologies, IATA-CSIC, Valencia, Spain
| | | | - Francisco M Codoñer
- ADM-Lifesequencing - Health and Wellness - Adm Nutrition, Valencia, Spain
- Danone Nutricia Research, Singapore, Singapore
| | - Gloria Sánchez
- Department of Preservation and Food Safety Technologies, IATA-CSIC, Valencia, Spain
| |
Collapse
|
3
|
Tang M, Liao N, Tian P, Shen K, Liu C, Ruan L, Wu G. Use of bentonite-coated activated carbon for improving the sensitivity of RT-qPCR detection of norovirus from vegetables and fruits: The ISO 15216-1:2017 standard method extension. Food Microbiol 2023; 110:104165. [PMID: 36462822 DOI: 10.1016/j.fm.2022.104165] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 10/08/2022] [Accepted: 10/10/2022] [Indexed: 11/16/2022]
Abstract
Produce-related foodborne outbreaks are becoming increasingly prevalent worldwide. In plant tissues, various compounds, including polysaccharides, phenolic compounds, and chlorophyll, can inhibit RT-PCR detection of viruses. In this study, we developed a highly sensitive RT-qPCR in combination with the bentonite-coated activated carbon (BCAC) assay for detection of norovirus from fruits and vegetables, which could be completed within 7 h and was about 10-100 fold more sensitive than the standard procedures (ISO 15216-1:2017). The extraction efficiencies of three surrogate viruses (MS2, MNV-1, and TV) from five fresh produce (lettuce, cherry tomato, blueberry, strawberry, and spinach) were higher with BCAC treatment than those of control groups, ranging from 17.82% to 98.60%. The average detection limit of these viruses using the BCAC-RT-qPCR method was stable at an average of 102 PFU/g or GC/g. Finally, this BCAC-RT-qPCR method was applied for detection of human norovirus GII.4 spiked onto lettuce and cherry tomato. The viral extraction efficiencies were up to 53.43% and 95.56%, respectively, which is almost four and seven times better than those without BCAC. Therefore, the BCAC-RT-qPCR method can be used to detect low levels of foodborne viruses from produce.
Collapse
Affiliation(s)
- Mengxuan Tang
- School of Food Science & Engineering, Jiangxi Agricultural University, Nanchang, 330045, China
| | - Ningbo Liao
- School of Food Science & Engineering, Jiangxi Agricultural University, Nanchang, 330045, China; Jiangxi Province Key Laboratory of Diagnosing and Tracing of Foodborne Disease, Nanchang, Jiangxi, China.
| | - Peng Tian
- Produce Safety and Microbiology Research Unit, Western Regional Research Center, Agricultural Research Service, United States Department of Agriculture, Albany, CA, United States
| | - Kaisheng Shen
- School of Food Science & Engineering, Jiangxi Agricultural University, Nanchang, 330045, China
| | - Chengwei Liu
- Jiangxi Province Key Laboratory of Diagnosing and Tracing of Foodborne Disease, Nanchang, Jiangxi, China; Jiangxi Province Center for Disease Control and Prevention, Nanchang, Jiangxi, China
| | - Lu Ruan
- School of Food Science & Engineering, Jiangxi Agricultural University, Nanchang, 330045, China
| | - Guoping Wu
- School of Food Science & Engineering, Jiangxi Agricultural University, Nanchang, 330045, China.
| |
Collapse
|
4
|
Forés E, Rusiñol M, Itarte M, Martínez-Puchol S, Calvo M, Bofill-Mas S. Evaluation of a virus concentration method based on ultrafiltration and wet foam elution for studying viruses from large-volume water samples. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 829:154431. [PMID: 35278558 DOI: 10.1016/j.scitotenv.2022.154431] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 03/04/2022] [Accepted: 03/05/2022] [Indexed: 06/14/2023]
Abstract
Assessing the presence of viruses in large-volume samples involves cumbersome methods that require specialized training and laboratory equipment. In this study, a large volume concentration (LVC) method, based on dead-end ultrafiltration (DEUF) and Wet Foam Elution™ technology, was evaluated in different type of waters and different microorganisms. Its recovery efficiency was evaluated through different techniques (infectivity assays and molecular detection) by spiking different viral surrogates (bacteriophages PhiX174 and MS2 and Coxsackie virus B5 (CVB5) and Escherichia coli (E. coli). Furthermore, the application of a secondary concentration step was evaluated and compared with skimmed milk flocculation. Viruses present in river water, seawater and groundwater samples were concentrated by applying LVC method and a centrifugal ultrafiltration device (CeUF), as a secondary concentration step and quantified with specific qPCR Human adenoviruses (HAdV) and noroviruses (NoVs). MS2 was used as process control, obtaining a mean viral recovery of 22.0 ± 12.47%. The presence of other viruses was also characterized by applying two different next-generation sequencing approaches. LVC coupled to a secondary concentration step based on CeUF allowed to detect naturally occurring viruses such as HAdV and NoVs in different water matrices. Using HAdV as a human fecal indicator, the highest viral pollution was found in river water samples (100% of positive samples), followed by seawater (83.33%) and groundwater samples (66.67%). The LVC method has also proven to be useful as a virus concentration method in the filed since HAdV and NoVs were detected in the river water and groundwater samples concentrated in the field. All in all, LVC method presents high concentration factor and a low limit of detection and provides viral concentrates useful for subsequent molecular analysis such as PCR and massive sequencing.
Collapse
Affiliation(s)
- Eva Forés
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain; The Water Research Institute (IdRA), Universitat de Barcelona, Barcelona, Catalonia, Spain
| | - Marta Rusiñol
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain; Institute of Environmental Assessment & Water Research (IDAEA), CSIC, Barcelona, Catalonia, Spain.
| | - Marta Itarte
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain; The Water Research Institute (IdRA), Universitat de Barcelona, Barcelona, Catalonia, Spain
| | - Sandra Martínez-Puchol
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain; The Water Research Institute (IdRA), Universitat de Barcelona, Barcelona, Catalonia, Spain
| | - Miquel Calvo
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain
| | - Sílvia Bofill-Mas
- Laboratory of Viruses Contaminants of Water and Food, Genetics, Microbiology & Statistics Department at the University of Barcelona (UB), Barcelona, Catalonia, Spain; The Water Research Institute (IdRA), Universitat de Barcelona, Barcelona, Catalonia, Spain
| |
Collapse
|
5
|
Taengphu S, Kayansamruaj P, Kawato Y, Delamare-Deboutteville J, Mohan CV, Dong HT, Senapin S. Concentration and quantification of Tilapia tilapinevirus from water using a simple iron flocculation coupled with probe-based RT-qPCR. PeerJ 2022; 10:e13157. [PMID: 35462762 PMCID: PMC9022640 DOI: 10.7717/peerj.13157] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 03/02/2022] [Indexed: 01/12/2023] Open
Abstract
Background Tilapia tilapinevirus, also known as tilapia lake virus (TiLV), is a significant virus that is responsible for the die-off of farmed tilapia across the globe. The detection and quantification of the virus using environmental RNA (eRNA) from pond water samples represents a potentially non-invasive and routine strategy for monitoring pathogens and early disease forecasting in aquaculture systems. Methods Here, we report a simple iron flocculation method for concentrating viruses in water, together with a newly-developed hydrolysis probe quantitative RT-qPCR method for the detection and quantification of TiLV. Results The RT-qPCR method designed to target a conserved region of the TiLV genome segment 9 has a detection limit of 10 viral copies per µL of template. The method had a 100% analytical specificity and sensitivity for TiLV. The optimized iron flocculation method was able to recover 16.11 ± 3.3% of the virus from water samples spiked with viral cultures. Tilapia and water samples were collected for use in the detection and quantification of TiLV disease during outbreaks in an open-caged river farming system and two earthen fish farms. TiLV was detected from both clinically sick and asymptomatic fish. Most importantly, the virus was successfully detected from water samples collected from different locations in the affected farms (i.e., river water samples from affected cages (8.50 × 103 to 2.79 × 105 copies/L) and fish-rearing water samples, sewage, and reservoir (4.29 × 103 to 3.53 × 104 copies/L)). By contrast, TiLV was not detected in fish or water samples collected from two farms that had previously experienced TiLV outbreaks and from one farm that had never experienced a TiLV outbreak. In summary, this study suggests that the eRNA detection system using iron flocculation, coupled with probe based-RT-qPCR, is feasible for use in the concentration and quantification of TiLV from water. This approach may be useful for the non-invasive monitoring of TiLV in tilapia aquaculture systems and may support evidence-based decisions on biosecurity interventions needed.
Collapse
Affiliation(s)
- Suwimon Taengphu
- Fish Health Platform, Center of Excellence for Shrimp Molecular Biology and Biotechnology (Centex Shrimp), Mahidol University, Phayathai, Bangkok, Thailand
| | - Pattanapon Kayansamruaj
- Center of Excellence in Aquatic Animal Health Management, Faculty of Fisheries, Kasetsart University, Chatuchak, Bangkok, Thailand
| | - Yasuhiko Kawato
- Pathology Division, Nansei Field Station, Fisheries Technology Institute, Japan Fisheries Research and Education Agency, Minami-Ise, Mie, Japan
| | | | | | - Ha Thanh Dong
- School of Environment, Resources and Development, Asian Institute of Technology, Klong Luang, Pathum Thani, Thailand
| | - Saengchan Senapin
- Fish Health Platform, Center of Excellence for Shrimp Molecular Biology and Biotechnology (Centex Shrimp), Mahidol University, Phayathai, Bangkok, Thailand,National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), Klong Luang, Pathum Thani, Thailand
| |
Collapse
|
6
|
Taengphu S, Kayansamruaj P, Kawato Y, Delamare-Deboutteville J, Mohan CV, Dong HT, Senapin S. Concentration and quantification of Tilapia tilapinevirus from water using a simple iron flocculation coupled with probe-based RT-qPCR. PeerJ 2022. [PMID: 35462762 DOI: 10.1101/2021.08.10.455809] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2023] Open
Abstract
BACKGROUND Tilapia tilapinevirus, also known as tilapia lake virus (TiLV), is a significant virus that is responsible for the die-off of farmed tilapia across the globe. The detection and quantification of the virus using environmental RNA (eRNA) from pond water samples represents a potentially non-invasive and routine strategy for monitoring pathogens and early disease forecasting in aquaculture systems. METHODS Here, we report a simple iron flocculation method for concentrating viruses in water, together with a newly-developed hydrolysis probe quantitative RT-qPCR method for the detection and quantification of TiLV. RESULTS The RT-qPCR method designed to target a conserved region of the TiLV genome segment 9 has a detection limit of 10 viral copies per µL of template. The method had a 100% analytical specificity and sensitivity for TiLV. The optimized iron flocculation method was able to recover 16.11 ± 3.3% of the virus from water samples spiked with viral cultures. Tilapia and water samples were collected for use in the detection and quantification of TiLV disease during outbreaks in an open-caged river farming system and two earthen fish farms. TiLV was detected from both clinically sick and asymptomatic fish. Most importantly, the virus was successfully detected from water samples collected from different locations in the affected farms (i.e., river water samples from affected cages (8.50 × 103 to 2.79 × 105 copies/L) and fish-rearing water samples, sewage, and reservoir (4.29 × 103 to 3.53 × 104 copies/L)). By contrast, TiLV was not detected in fish or water samples collected from two farms that had previously experienced TiLV outbreaks and from one farm that had never experienced a TiLV outbreak. In summary, this study suggests that the eRNA detection system using iron flocculation, coupled with probe based-RT-qPCR, is feasible for use in the concentration and quantification of TiLV from water. This approach may be useful for the non-invasive monitoring of TiLV in tilapia aquaculture systems and may support evidence-based decisions on biosecurity interventions needed.
Collapse
Affiliation(s)
- Suwimon Taengphu
- Fish Health Platform, Center of Excellence for Shrimp Molecular Biology and Biotechnology (Centex Shrimp), Mahidol University, Phayathai, Bangkok, Thailand
| | - Pattanapon Kayansamruaj
- Center of Excellence in Aquatic Animal Health Management, Faculty of Fisheries, Kasetsart University, Chatuchak, Bangkok, Thailand
| | - Yasuhiko Kawato
- Pathology Division, Nansei Field Station, Fisheries Technology Institute, Japan Fisheries Research and Education Agency, Minami-Ise, Mie, Japan
| | | | | | - Ha Thanh Dong
- School of Environment, Resources and Development, Asian Institute of Technology, Klong Luang, Pathum Thani, Thailand
| | - Saengchan Senapin
- Fish Health Platform, Center of Excellence for Shrimp Molecular Biology and Biotechnology (Centex Shrimp), Mahidol University, Phayathai, Bangkok, Thailand
- National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), Klong Luang, Pathum Thani, Thailand
| |
Collapse
|
7
|
Lu J, Yang S, Zhang X, Tang X, Zhang J, Wang X, Wang H, Shen Q, Zhang W. Metagenomic Analysis of Viral Community in the Yangtze River Expands Known Eukaryotic and Prokaryotic Virus Diversity in Freshwater. Virol Sin 2022; 37:60-69. [PMID: 35234628 PMCID: PMC8922420 DOI: 10.1016/j.virs.2022.01.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Accepted: 09/03/2021] [Indexed: 11/16/2022] Open
Abstract
Viruses in aquatic ecosystems are characterized by extraordinary abundance and diversity. Thus far, there have been limited studies focused on viral communities in river water systems. Here, we investigated the virome of the Yangtze River Delta using viral metagenomic analysis. The compositions of viral communities from six sampling sites were analyzed and compared. By using library construction and next generation sequencing, contigs and singlet reads similar to viral sequences were classified into 17 viral families, including nine dsDNA viral families, four ssDNA viral families and four RNA viral families. Statistical analysis using Friedman test suggested that there was no significant difference among the six sampling sites (P > 0.05). The viromes in this study were all dominated by the order Caudovirales, and a group of Freshwater phage uvFW species were particularly prevalent among all the samples. The virome from Nanjing presented a unique pattern of viral community composition with a relatively high abundance of family Parvoviridae. Phylogenetic analyses based on virus hallmark genes showed that the Caudovirales order and CRESS-DNA viruses presented high genetic diversity, while viruses in the Microviridae and Parvoviridae families and the Riboviria realm were relatively conservative. Our study provides the first insight into viral community composition in large river ecosystem, revealing the diversity and stability of river water virome, contributing to the proper utilization of freshwater resource. First insight into viral community composition in large river ecosystem. Virus hallmark genes present both diverse and conservative characteristics. The composition of viral communities is similar on the whole. Slight regional variation of virome is existed in individual areas.
Collapse
|
8
|
Flood MT, D'Souza N, Rose JB, Aw TG. Methods Evaluation for Rapid Concentration and Quantification of SARS-CoV-2 in Raw Wastewater Using Droplet Digital and Quantitative RT-PCR. FOOD AND ENVIRONMENTAL VIROLOGY 2021; 13:303-315. [PMID: 34296387 PMCID: PMC8297606 DOI: 10.1007/s12560-021-09488-8] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Accepted: 07/13/2021] [Indexed: 05/20/2023]
Abstract
Wastewater surveillance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an emerging public health tool to understand the spread of Coronavirus Disease 2019 (COVID-19) in communities. The performance of different virus concentration methods and PCR methods needs to be evaluated to ascertain their suitability for use in the detection of SARS-CoV-2 in wastewater. We evaluated ultrafiltration and polyethylene glycol (PEG) precipitation methods to concentrate SARS-CoV-2 from sewage in wastewater treatment plants and upstream in the wastewater network (e.g., manholes, lift stations). Recovery of viruses by different concentration methods was determined using Phi6 bacteriophage as a surrogate for enveloped viruses. Additionally, the presence of SARS-CoV-2 in all wastewater samples was determined using reverse transcription quantitative PCR (RT-qPCR) and reverse transcription droplet digital PCR (RT-ddPCR), targeting three genetic markers (N1, N2 and E). Using spiked samples, the Phi6 recoveries were estimated at 2.6-11.6% using ultrafiltration-based methods and 22.2-51.5% using PEG precipitation. There was no significant difference in recovery efficiencies (p < 0.05) between the PEG procedure with and without a 16 h overnight incubation, demonstrating the feasibility of obtaining same day results. The SARS-CoV-2 genetic markers were more often detected by RT-ddPCR than RT-qPCR with higher sensitivity and precision. While all three SARS-CoV-2 genetic markers were detected using RT-ddPCR, the levels of E gene were almost below the limit of detection using RT-qPCR. Collectively, our study suggested PEG precipitation is an effective low-cost procedure which allows a large number of samples to be processed simultaneously in a routine wastewater monitoring for SARS-CoV-2. RT-ddPCR can be implemented for the absolute quantification of SARS-CoV-2 genetic markers in different wastewater matrices.
Collapse
Affiliation(s)
- Matthew T Flood
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, 48824, USA
| | - Nishita D'Souza
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, 48824, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI, 48824, USA
| | - Tiong Gim Aw
- Department of Environmental Health Sciences, School of Public Health and Tropical Medicine, Tulane University, 1440 Canal Street, Suite 2100, New Orleans, LA, 70112, USA.
| |
Collapse
|
9
|
Hennechart-Collette C, Dehan O, Fraisse A, Martin-Latil S, Perelle S. Evaluation of three different filters and two methods for recovering viruses from drinking water. J Virol Methods 2020; 284:113939. [PMID: 32673640 DOI: 10.1016/j.jviromet.2020.113939] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2020] [Revised: 07/10/2020] [Accepted: 07/12/2020] [Indexed: 01/13/2023]
Abstract
Among the enteric viruses implicated in waterborne outbreaks, human norovirus and hepatitis A virus (HAV) are a serious public health issue. Most foodborne viruses are difficult or currently unlikely to cultivate. Because of the lack of a cell culture method, real-time reverse transcriptase PCR is commonly used for the detection of norovirus in foodstuffs and environmental samples. Due to low infectious doses in humans and low virus concentration in water sample, filter adsorption methods were used for concentrating viruses from water. The ISO (Anonymous, ISO 15216-1, 2017) describes standardized molecular methods for detecting HAV and norovirus in bottled water. This method includes a two-step procedure: concentrating the virus using a microporous electropositive filter (47 mm diameter, 0.45 μm pore size) then molecular detection. The Zetapor filter, which had a charged membrane with a pore size of 0.45 μm, was commonly used in the past to concentrate viruses from water or from salad leaves following virus elution. But, unfortunately, the Zetapor filter is no longer marketed and it is therefore necessary to assess an alternative filter. The aim of this study was to compare the ability of two electropositive filters with a pore size of 0.45 μm or 0.22 μm and one uncharged filter (0.45 μm) to recover norovirus and HAV from two different types of drinking water (bottled water and tap water) with the adsorption-elution method proposed by ISO (Anonymous, ISO 15216-1, 2017) (method A) and with direct viral extraction using filters (method B). The mean extraction yields for norovirus and HAV calculated with RNA extracts ranged from 0.2 % - 4.81 % with method A and from 5.05 % - 53.58 % with method B, and did not differ significantly between the two types of drinking water tested. For method B, the mean extraction yields for HAV and norovirus were evaluated according to results from the three filters used. The recovery rate of HAV and norovirus ranged between 3.47 % and 62.41 % with the 0.45 μm electropositive filter and were higher than the other filters. The 0.45 μm electropositive filter could be used to concentrate viruses for routine viral monitoring of drinking water for researchers who want to adopt the method in their lab routine.
Collapse
Affiliation(s)
| | - Océane Dehan
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Audrey Fraisse
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Sandra Martin-Latil
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France
| | - Sylvie Perelle
- Université Paris-Est, ANSES, Laboratory for Food Safety, F-94700 Maisons-Alfort, France.
| |
Collapse
|
10
|
Hata A, Furumai H, Katayama H. Sequential treatment using a hydrophobic resin and gel filtration to improve viral gene quantification from highly complex environmental concentrates. WATER RESEARCH 2020; 174:115652. [PMID: 32135428 DOI: 10.1016/j.watres.2020.115652] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Revised: 02/24/2020] [Accepted: 02/24/2020] [Indexed: 06/10/2023]
Abstract
Assays based on the polymerase chain reaction (PCR) are widely applied to quantify enteric viruses in aquatic environments to study their fates and potential infection risks. However, inhibitory substances enriched by virus concentration processes can result in inaccurate quantification. This study aimed to find a method for improving virus quantification by mitigating the effects of inhibitory environmental concentrates, using previous knowledge of the properties of the inhibitory substances. Performances of anion exchange resins, gel filtration, and a hydrophobic resin (DAX-8) were comparatively evaluated using poliovirus and its extracted RNA spiked into humic acid solutions. These solutions served as good representatives of the inhibitory environmental concentrates. A sequential treatment using DAX-8 resin and gel filtration produced the most favorable results, i.e., low virus losses that were stable and a reduced inhibitory effect. Furthermore, the sequential treatment was applied to another set of 15 environmental concentrates. Without the sequential treatment, serious underestimation (>4.0 log10 to 1.1 log10) of a molecular process control (murine norovirus) was measured for eight samples. With the treatment, the control was detected with <1.0 log10 underestimation for all samples. The treatment improved the quantification of seven types of indigenous viruses. In summary, the sequential treatment is effective in improving the viral quantification in various of environmental concentrates.
Collapse
Affiliation(s)
- Akihiko Hata
- Department of Environmental and Civil Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-shi, Toyama, 939-0398, Japan.
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan
| | - Hiroyuki Katayama
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan
| |
Collapse
|
11
|
Ahmed W, Payyappat S, Cassidy M, Harrison N, Besley C. Sewage-associated marker genes illustrate the impact of wet weather overflows and dry weather leakage in urban estuarine waters of Sydney, Australia. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 705:135390. [PMID: 31838427 DOI: 10.1016/j.scitotenv.2019.135390] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Revised: 11/03/2019] [Accepted: 11/04/2019] [Indexed: 05/18/2023]
Abstract
This study investigates the impact of wet weather overflows (WWOs) at three estuarine locations in Sydney, NSW, Australia. WWOs can occur when infiltration of stormwater leads to an excess volume of flow within the sewerage system, resulting in the release of diluted sewage into the environment. Sewage contamination poses a risk to human health due to the presence of pathogens. The magnitude of sewage contamination was monitored using established and novel sewage-associated marker genes, Bacteroides HF183, pepper mild mottle virus (PMMoV), crAssphage CPQ_056, Lachnospiraceae (Lachno3) marker genes along with culturable fecal indicator bacteria (FIB) Escherichia coli (E. coli) and enterococci. Water samples were collected at two water depths (0.5 m below the water surface and 1 m above the bottom surface) during one dry weather and two storm events. Analysis of sewage-associated marker genes showed greater (i.e., 3-5 orders of magnitude) concentrations in water samples collected during the storm events compared to dry weather event. Water samples were also analysed for four animal feces-associated marker genes targeting avian (GFD), dog (BacCan-UCD), cow (cowM2) and horse (HoF597) species to determine the extent of animal fecal contamination. Among the four marker genes, cowM2 and HoF597 could not be detected, while GFD marker gene was consistently present and BacCan-UCD was occasionally detected. Overall results suggested that after rainfall, untreated sewage from WWOs was present at sampling locations. In addition, microbial source tracking (MST) monitoring was able to distinguish the presence of a leaking sewer impacting on the recreational area during dry weather condition. This study demonstrated the capability of the MST monitoring approach to understand sources (sewage or animal) of fecal contamination. This capability will greatly enhance management decisions assisting in the prioritisation of remediation efforts of the sewerage system to improve estuarine bathing water quality and diminish human health risk.
Collapse
Affiliation(s)
- Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Dutton Park, QLD 4102, Australia.
| | - Sudhi Payyappat
- Sydney Water, 1 Smith Street, Parramatta, NSW 2150, Australia
| | - Michele Cassidy
- Sydney Water, 1 Smith Street, Parramatta, NSW 2150, Australia
| | - Nathan Harrison
- Sydney Water, 1 Smith Street, Parramatta, NSW 2150, Australia
| | - Colin Besley
- Sydney Water, 1 Smith Street, Parramatta, NSW 2150, Australia
| |
Collapse
|
12
|
Haramoto E, Kitajima M, Hata A, Torrey JR, Masago Y, Sano D, Katayama H. A review on recent progress in the detection methods and prevalence of human enteric viruses in water. WATER RESEARCH 2018; 135:168-186. [PMID: 29471200 DOI: 10.1016/j.watres.2018.02.004] [Citation(s) in RCA: 244] [Impact Index Per Article: 40.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2017] [Revised: 02/01/2018] [Accepted: 02/02/2018] [Indexed: 05/17/2023]
Abstract
Waterborne human enteric viruses, such as noroviruses and adenoviruses, are excreted in the feces of infected individuals and transmitted via the fecal-oral route including contaminated food and water. Since viruses are normally present at low concentrations in aquatic environments, they should be concentrated into smaller volumes prior to downstream molecular biological applications, such as quantitative polymerase chain reaction (qPCR). This review describes recent progress made in the development of concentration and detection methods of human enteric viruses in water, and discusses their applications for providing a better understanding of the prevalence of the viruses in various types of water worldwide. Maximum concentrations of human enteric viruses in water that have been reported in previous studies are summarized to assess viral abundances in aquatic environments. Some descriptions are also available on recent applications of sequencing analyses used to determine the genetic diversity of viral genomes in water samples, including those of novel viruses. Furthermore, the importance and significance of utilizing appropriate process controls during viral analyses are discussed, and three types of process controls are considered: whole process controls, molecular process controls, and (reverse transcription (RT)-)qPCR controls. Although no standards have been established for acceptable values of virus recovery and/or extraction-(RT-)qPCR efficiency, use of at least one of these appropriate control types is highly recommended for more accurate interpretation of observed data.
Collapse
Affiliation(s)
- Eiji Haramoto
- Interdisciplinary Center for River Basin Environment, Graduate Faculty of Interdisciplinary Research, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan.
| | - Masaaki Kitajima
- Division of Environmental Engineering, Faculty of Engineering, Hokkaido University, North 13 West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan.
| | - Akihiko Hata
- Integrated Research System for Sustainability Science, Institutes for Advanced Study, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan.
| | - Jason R Torrey
- School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
| | - Yoshifumi Masago
- Institute for the Advanced Study of Sustainability, United Nations University, 5-53-70 Jingumae, Shibuya-ku, Tokyo 150-8925, Japan.
| | - Daisuke Sano
- Department of Civil and Environmental Engineering, Graduate School of Engineering, Tohoku University, Aoba 6-6-06, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579, Japan.
| | - Hiroyuki Katayama
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan; Vietnam Japan University, Luu Huu Phuoc Road, My Dinh 1 Ward, Nam Tu Liem District, Ha Noi, Vietnam.
| |
Collapse
|
13
|
Abstract
Viruses represent the most abundant and diverse of the biological entities in environmental waters, including the seas and probably also freshwater systems. They are important players in ecological networks in waters and influence global biochemical cycling and community composition dynamics. Among the many diverse viruses from terrestrial environments found in environmental waters, some are plant, animal, and/or human pathogens. The majority of pathogenic viral species found in waters are very stable and can survive outside host cells for long periods. The occurrence of such viruses in environmental waters has raised concerns because of the confirmation of the infectivity of waterborne viruses even at very low concentrations. This chapter focuses mainly on the survival of human, animal, and plant pathogenic viruses in aqueous environments, the possibility of their water-mediated transmission, the ecological implications of viruses in water, the methods adapted for detecting such viruses, and how to minimize the risk of viruses spreading through water.
Collapse
|
14
|
Castells M, Schild C, Caffarena D, Bok M, Giannitti F, Armendano J, Riet-Correa F, Victoria M, Parreño V, Colina R. Prevalence and viability of group A rotavirus in dairy farm water sources. J Appl Microbiol 2018; 124:922-929. [PMID: 29316065 DOI: 10.1111/jam.13691] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Revised: 12/30/2017] [Accepted: 01/02/2018] [Indexed: 12/27/2022]
Abstract
AIM To analyse group A rotavirus (RVA) environmental contamination in waters used for calves' consumption and to assess viral viability in dairy farm water sources. METHODS AND RESULTS We analysed 202 samples of water used for calves' consumption and RVA was detected by RT-qPCR in 35·1% (95% CI: 28·9-42·0%). A marked pattern of seasonality was observed with higher frequency of detection in colder than warmer months (P = 0·002). There was no association between viral load and season or between the number of milking cows in the herd and the detection of RVA in the farm. The viability of the RVA particles detected was confirmed by isolation of RVA in cell culture from 5 of 10 water samples. Furthermore, an RVA waterborne outbreak of neonatal calf diarrhoea was described. CONCLUSIONS We demonstrate that RVA is frequent in dairy farm waters, and that the virus is infectious and capable of generating a diarrhoea outbreak. SIGNIFICANCE AND IMPACT OF THE STUDY Neonatal diarrhoea syndrome leads to economic losses to the livestock industry worldwide. To determine transmission routes is essential to take action in this regard and reduce the impact that this syndrome has for the livestock production. The results obtained in this work alert the dairy industry and highlight that mitigation strategies are crucial to improve the microbiological quality of this water.
Collapse
Affiliation(s)
- M Castells
- Laboratorio de Virología Molecular, CENUR Litoral Norte, Centro Universitario de Salto, Universidad de la República, Salto, Uruguay
| | - C Schild
- Plataforma de Investigación en Salud Animal, Instituto Nacional de Investigación Agropecuaria (INIA), La Estanzuela, Colonia, Uruguay
| | - D Caffarena
- Plataforma de Investigación en Salud Animal, Instituto Nacional de Investigación Agropecuaria (INIA), La Estanzuela, Colonia, Uruguay
| | - M Bok
- Sección de Virus Gastroentéricos, Instituto de Virología, CICV y A, INTA Castelar, Buenos Aires, Argentina
| | - F Giannitti
- Plataforma de Investigación en Salud Animal, Instituto Nacional de Investigación Agropecuaria (INIA), La Estanzuela, Colonia, Uruguay.,Veterinary Population Medicine Department, College of Veterinary Medicine, University of Minnesota, Saint Paul, MN, USA
| | - J Armendano
- Facultad de Ciencias Agrarias, Universidad Nacional de Mar del Plata, Balcarce, Buenos Aires, Argentina
| | - F Riet-Correa
- Plataforma de Investigación en Salud Animal, Instituto Nacional de Investigación Agropecuaria (INIA), La Estanzuela, Colonia, Uruguay
| | - M Victoria
- Laboratorio de Virología Molecular, CENUR Litoral Norte, Centro Universitario de Salto, Universidad de la República, Salto, Uruguay
| | - V Parreño
- Sección de Virus Gastroentéricos, Instituto de Virología, CICV y A, INTA Castelar, Buenos Aires, Argentina
| | - R Colina
- Laboratorio de Virología Molecular, CENUR Litoral Norte, Centro Universitario de Salto, Universidad de la República, Salto, Uruguay
| |
Collapse
|
15
|
Junter GA, Lebrun L. Cellulose-based virus-retentive filters: a review. RE/VIEWS IN ENVIRONMENTAL SCIENCE AND BIO/TECHNOLOGY 2017; 16:455-489. [PMID: 32214924 PMCID: PMC7088658 DOI: 10.1007/s11157-017-9434-1] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
Viral filtration is a critical step in the purification of biologics and in the monitoring of microbiological water quality. Viral filters are also essential protection elements against airborne viral particles. The present review first focuses on cellulose-based filter media currently used for size-exclusion and/or adsorptive filtration of viruses from biopharmaceutical and environmental water samples. Data from spiking studies quantifying the viral filtration performance of cellulosic filters are detailed, i.e., first, the virus reduction capacity of regenerated cellulose hollow fiber filters in the manufacturing process of blood products and, second, the efficiency of virus recovery/concentration from water samples by the viradel (virus adsorption-elution) method using charge modified, electropositive cellulosic filters or conventional electronegative cellulose ester microfilters. Viral analysis of field water samples by the viradel technique is also surveyed. This review then describes cellulose-based filter media used in individual protection equipment against airborne viral pathogens, presenting innovative filtration media with virucidal properties. Some pros and cons of cellulosic viral filters and perspectives for cellulose-based materials in viral filtration are underlined in the review.
Collapse
Affiliation(s)
- Guy-Alain Junter
- Normandie Univ, UNIROUEN Normandie, INSA Rouen, CNRS, PBS, 76000 Rouen, France
| | - Laurent Lebrun
- Normandie Univ, UNIROUEN Normandie, INSA Rouen, CNRS, PBS, 76000 Rouen, France
| |
Collapse
|
16
|
Vizzini P, Iacumin L, Comi G, Manzano M. Development and application of DNA molecular probes. AIMS BIOENGINEERING 2017. [DOI: 10.3934/bioeng.2017.1.113] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
17
|
Balasubramanian MN, Rački N, Gonçalves J, Kovač K, Žnidarič MT, Turk V, Ravnikar M, Gutiérrez-Aguirre I. Enhanced detection of pathogenic enteric viruses in coastal marine environment by concentration using methacrylate monolithic chromatographic supports paired with quantitative PCR. WATER RESEARCH 2016; 106:405-414. [PMID: 27750129 DOI: 10.1016/j.watres.2016.10.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Revised: 10/06/2016] [Accepted: 10/07/2016] [Indexed: 06/06/2023]
Abstract
Currently, around 50% of the world's population lives in towns and cities within 100 km of the coast. Monitoring of viruses that are frequently present in contaminated coastal environments, such as rotavirus (RoV) and norovirus (NoV), which are also the major cause of human viral gastroenteritis, is essential to ensure the safe use of these water bodies. Since exposure to as few as 10-100 particles of RoV or NoV may induce gastrointestinal disease, there is a need to develop a rapid and sensitive diagnostic method for their detection in coastal water samples. In this study, we evaluate the application of methacrylate monolithic chromatographic columns, commercially available as convective interaction media (CIM®), to concentrate pathogenic enteric viruses from saline water samples prior to virus quantification by one-step reverse transcription quantitative PCR (RT-qPCR). Using RoV and NoV as model enteric viruses, we present our results on the most effective viral concentration conditions from saline water matrices using butyl (C4) hydrophobic interaction monolithic support (CIM® C4). C4 monolithic columns exhibit a good capacity to bind both RoV and NoV and both viruses can be eluted in a single step. Our protocol using a 1 ml C4 column enables processing of 400 ml saline water samples in less than 60 min and increases the sensitivity of RoV and NoV detection by approximately 50-fold and 10-fold respectively. The protocol was also scaled up using larger capacity 8 ml C4 columns to process 4000 ml of seawater samples with concentration factors of 300-fold for RoV and 40-fold for NoV, without any significant increase in processing time. Furthermore, C4 monolithic columns were adapted for field use in an on-site application of RoV concentration from seawater samples with performance equivalent to that of the reference laboratory setup. Overall, the results from successful deployment of CIM C4 columns for concentration of rotavirus and norovirus in seawater samples reiterate the utility of monolithic supports as efficient, scalable and modular preparative tools for processing environmental water samples to enhance viral detection using molecular methods.
Collapse
Affiliation(s)
| | - Nejc Rački
- Department of Biotechnology and Systems Biology, National Institute of Biology, Večna Pot 111, SI-1000, Ljubljana, Slovenia.
| | - José Gonçalves
- Marine Biology Station, National Institute of Biology, Fornače 41, SI-6330, Piran, Slovenia.
| | - Katarina Kovač
- BioSistemika LLC, Koprska 98, SI-1000, Ljubljana, Slovenia.
| | - Magda T Žnidarič
- Department of Biotechnology and Systems Biology, National Institute of Biology, Večna Pot 111, SI-1000, Ljubljana, Slovenia.
| | - Valentina Turk
- Marine Biology Station, National Institute of Biology, Fornače 41, SI-6330, Piran, Slovenia.
| | - Maja Ravnikar
- Department of Biotechnology and Systems Biology, National Institute of Biology, Večna Pot 111, SI-1000, Ljubljana, Slovenia.
| | - Ion Gutiérrez-Aguirre
- Department of Biotechnology and Systems Biology, National Institute of Biology, Večna Pot 111, SI-1000, Ljubljana, Slovenia.
| |
Collapse
|
18
|
Field-based evaluation of a male-specific (F+) RNA coliphage concentration method. J Virol Methods 2016; 239:9-16. [PMID: 27777078 DOI: 10.1016/j.jviromet.2016.10.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2016] [Revised: 10/18/2016] [Accepted: 10/19/2016] [Indexed: 11/24/2022]
Abstract
Fecal contamination of water poses a significant risk to public health due to the potential presence of pathogens, including enteric viruses. Therefore, sensitive, reliable and easy to use methods for the concentration, detection and quantification of microorganisms associated with the safety and quality of water are needed. In this study, we performed a field evaluation of an anion exchange resin-based method to concentrate male-specific (F+) RNA coliphages (FRNA), fecal indicator organisms, from diverse environmental waters that were suspected to be contaminated with feces. In this system, FRNA coliphages are adsorbed to anion exchange resin and direct nucleic acid isolation is performed, yielding a sample amenable to real-time reverse transcriptase (RT)-PCR detection. Matrix-dependent inhibition of this method was evaluated using known quantities of spiked FRNA coliphages belonging to four genogroups (GI, GII, GII and GIV). RT-PCR-based detection was successful in 97%, 72%, 85% and 98% of the samples spiked (106 pfu/l) with GI, GII, GIII and GIV, respectively. Differential FRNA coliphage genogroup detection was linked to inhibitors that altered RT-PCR assay efficiency. No association between inhibition and the physicochemical properties of the water samples was apparent. Additionally, the anion exchange resin method facilitated detection of naturally present FRNA coliphages in 40 of 65 environmental water samples (61.5%), demonstrating the viability of this system to concentrate FRNA coliphages from water.
Collapse
|
19
|
Hennechart-Collette C, Martin-Latil S, Guillier L, Perelle S. Determination of which virus to use as a process control when testing for the presence of hepatitis A virus and norovirus in food and water. Int J Food Microbiol 2015; 202:57-65. [PMID: 25771512 DOI: 10.1016/j.ijfoodmicro.2015.02.029] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 02/12/2015] [Accepted: 02/19/2015] [Indexed: 11/24/2022]
Abstract
Noroviruses (genogroup I (NoV GI) and genogroup II (NoV GII)) and the hepatitis A virus (HAV) are frequently involved in foodborne infections worldwide. They are mainly transmitted via the fecal-oral route, direct person-to-person contact or consumption of contaminated water and foods. In food virology, detection methods are currently based on identifying viral genomes using real-time reverse transcriptase PCR (RT-qPCR). One of the general requirements for detecting these viruses in food involves the use of a process control virus to monitor the quality of the entire viral extraction procedure as described in the ISO/TS 15216-1 and 15216-2 standards published in 2013. The selected process control virus should have similar morphological and physicochemical properties as the screened pathogenic virus and thus have the potential to provide comparable extraction efficiency. The aim of this study was to determine which virus should be used for process control, murine norovirus (MNV-1) or Mengovirus, when testing for the presence of HAV, NoV GI and NoV GII in bottled water, lettuce and semi-dried tomatoes. Food samples were spiked with HAV, NoV GI or NoV GII alone or in the presence of MNV-1 or Mengovirus. Recovery rates of each pathogenic virus were compared to those of both process control viruses using a multiple comparison procedure. Neither process control virus influenced the recovery of pathogenic virus regardless of the type of food matrix. MNV-1 was the most appropriate virus for validating the detection of HAV and NoV GII in all three food matrices as well as NoV GI in lettuce. Mengovirus proved to be the most appropriate control for NoV GI detection in bottled water and semi-dried tomatoes. The process control virus is essential for validating viral detection in food and the choice of virus depends on food type and the screened pathogenic virus.
Collapse
Affiliation(s)
- Catherine Hennechart-Collette
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Sandra Martin-Latil
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Laurent Guillier
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Quantitative Risk Assessment Mission, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France
| | - Sylvie Perelle
- Université Paris-Est, ANSES, Maisons-Alfort Laboratory for Food Safety, Enteric Viruses Unit, 14 rue Pierre et Marie Curie, 94701 Maisons-Alfort Cedex, France.
| |
Collapse
|
20
|
Hata A, Matsumori K, Kitajima M, Katayama H. Concentration of enteric viruses in large volumes of water using a cartridge-type mixed cellulose ester membrane. FOOD AND ENVIRONMENTAL VIROLOGY 2015; 7:7-13. [PMID: 25326201 DOI: 10.1007/s12560-014-9169-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2014] [Accepted: 10/14/2014] [Indexed: 05/22/2023]
Abstract
A viral adsorption-elution method using a flat/disk-type electronegative membrane (diameter of 47-90 mm) has been widely utilized to concentrate viruses in relatively small volumes of water (up to 10 L) due to limited filtration area. In the present study, we aimed to develop a virus concentration method that is based on the same principle and yet allows concentration of large volumes of water using a cartridge-type electronegative membrane. We modified two electronegative membrane-based methods for this purpose (i.e., Mg(2+) method and Al(3+) method) and determined recovery efficiencies of poliovirus and murine norovirus inoculated in water samples. The virus recovery efficiency of the Al(3+) method substantially decreased as the volume of water sample increased. In contrast, Mg(2+) method showed stable virus recovery efficiencies (10-54 %) even when 40 to 1,000 L of river and tap water samples were processed. The volume of the concentrate (400 mL) can be further reduced to 1.5 mL by a Centricon plus-70 centrifugal ultrafiltration device with overall recovery efficiencies of 8.8-16 %. Our results demonstrated that the newly developed virus concentration method enables detection of as low as 10(1) copies/L of viruses in water samples.
Collapse
Affiliation(s)
- Akihiko Hata
- Research Center for Environmental Quality Management, Kyoto University, 1-2 Yumihama, Otsu, Shiga, 520-0811, Japan,
| | | | | | | |
Collapse
|
21
|
Comparison of concentration methods for quantitative detection of sewage-associated viral markers in environmental waters. Appl Environ Microbiol 2015; 81:2042-9. [PMID: 25576614 DOI: 10.1128/aem.03851-14] [Citation(s) in RCA: 99] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Pathogenic human viruses cause over half of gastroenteritis cases associated with recreational water use worldwide. They are relatively difficult to concentrate from environmental waters due to typically low concentrations and their small size. Although rapid enumeration of viruses by quantitative PCR (qPCR) has the potential to greatly improve water quality analysis and risk assessment, the upstream steps of capturing and recovering viruses from environmental water sources along with removing PCR inhibitors from extracted nucleic acids remain formidable barriers to routine use. Here, we compared the efficiency of virus recovery for three rapid methods of concentrating two microbial source tracking (MST) viral markers human adenoviruses (HAdVs) and polyomaviruses (HPyVs) from one liter tap water and river water samples on HA membranes (90 mm in diameter). Samples were spiked with raw sewage, and viral adsorption to membranes was promoted by acidification (method A) or addition of MgCl2 (methods B and C). Viral nucleic acid was extracted directly from membranes (method A), or viruses were eluted with NaOH and concentrated by centrifugal ultrafiltration (methods B and C). No inhibition of qPCR was observed for samples processed by method A, but inhibition occurred in river samples processed by B and C. Recovery efficiencies of HAdVs and HPyVs were ∼10-fold greater for method A (31 to 78%) than for methods B and C (2.4 to 12%). Further analysis of membranes from method B revealed that the majority of viruses were not eluted from the membrane, resulting in poor recovery. The modification of the originally published method A to include a larger diameter membrane and a nucleic acid extraction kit that could accommodate the membrane resulted in a rapid virus concentration method with good recovery and lack of inhibitory compounds. The frequently used strategy of viral absorption with added cations (Mg(2+)) and elution with acid were inefficient and more prone to inhibition, and will result in underestimation of the prevalence and concentrations of HAdVs and HPyVs markers in environmental waters.
Collapse
|
22
|
Furtak VA, Dabrazhynetskaya A, Volokhov DV, Chizhikov V. Use of tangential flow filtration for improving detection of viral adventitious agents in cell substrates. Biologicals 2014; 43:23-30. [PMID: 25432087 DOI: 10.1016/j.biologicals.2014.10.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2014] [Revised: 10/03/2014] [Accepted: 10/27/2014] [Indexed: 11/28/2022] Open
Abstract
In this study, we assessed the feasibility of tangential flow filtration (TFF) for primary concentration of viral adventitious agents (AAs) from large volumes of cell substrate-derived samples, such as cell-free Chinese hamster ovary (CHO) culture supernatants (500 mL) and CHO cell lysates (50 mL), prior to virus detection in them by nucleic acid-based methods (i.e., qPCR and massively parallel sequencing (MPS). The study was conducted using the samples spiked with four model DNA viruses (bovine herpesvirus type 4, human adenovirus type 5, simian polyomavirus SV-40, and bovine parvovirus). The results showed that the combined TFF/MPS approach enables reliable detection of as low as 1000 genome equivalents (GE) of each of the four viruses spiked into the cell substrate samples. The final achieved sensitivities of 2 GE/mL for cell culture supernatant and 20 GE/mL for cell lysate make this approach more sensitive than virus-specific PCR and qPCR assays. The study results allowed us to propose that TFF might be useful and valuable method for simple and rapid concentration of potential AAs in cell substrate samples prior to AAs detection by conventional in vivo, in vitro, or molecular methods.
Collapse
Affiliation(s)
- Vyacheslav A Furtak
- Center for Biologics Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD, USA
| | - Alena Dabrazhynetskaya
- Center for Biologics Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD, USA
| | - Dmitriy V Volokhov
- Center for Biologics Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD, USA
| | - Vladimir Chizhikov
- Center for Biologics Evaluation and Research, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD, USA.
| |
Collapse
|
23
|
Comparison of ZetaPlus 60S and nitrocellulose membrane filters for the simultaneous concentration of F-RNA coliphages, porcine teschovirus and porcine adenovirus from river water. J Virol Methods 2014; 206:5-11. [PMID: 24880068 DOI: 10.1016/j.jviromet.2014.05.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2014] [Revised: 05/14/2014] [Accepted: 05/20/2014] [Indexed: 01/13/2023]
Abstract
Increasing attention is being paid to the impact of agricultural activities on water quality to understand the impact on public health. F-RNA coliphages have been proposed as viral indicators of fecal contamination while porcine teschovirus (PTV) and porcine adenovirus (PAdV) are proposed indicators of fecal contamination of swine origin. Viruses and coliphages are present in water in very low concentrations and must be concentrated to permit their detection. There is little information comparing the effectiveness of the methods for concentrating F-RNA coliphages with concentration methods for other viruses and vice versa. The objective of this study was to compare 5 current published methods for recovering F-RNA coliphages, PTV and PAdV from river water samples concentrated by electronegative nitrocellulose membrane filters (methods A and B) or electropositive Zeta Plus 60S filters (methods C-E). Method A is used routinely for the detection of coliphages (Méndez et al., 2004) and method C (Brassard et al., 2005) is the official method in Health Canada's compendium for the detection of viruses in bottled mineral or spring water. When river water was inoculated with stocks of F-RNA MS2, PAdV, and PTV to final concentrations of 1×10(6) PFU/100 mL, 1×10(5) gc/100 mL and 3×10(5) gc/100 mL, respectively, a significantly higher recovery for each virus was consistently obtained for method A with recoveries of 52% for MS2, 95% for PAdV, and 1.5% for PTV. When method A was compared with method C for the detection of F-coliphages, PAdV and PTV in river water samples, viruses were detected with higher frequencies and at higher mean numbers with method A than with method C. With method A, F-coliphages were detected in 11/12 samples (5-154 PFU/100 mL), PTV in 12/12 samples (397-10,951 gc/100 mL), PAdV in 1/12 samples (15 gc/100 mL), and F-RNA GIII in 1/12 samples (750 gc/100 mL) while F-RNA genotypes I, II, and IV were not detected by qRT-PCR.
Collapse
|
24
|
Griffin SM, Brinkman NE, Hedrick EJ, Rhodes ER, Fout GS. Comparison of nucleic acid extraction and reverse transcription-qPCR approaches for detection of GI and GII noroviruses in drinking water. J Virol Methods 2014; 199:76-85. [PMID: 24462844 DOI: 10.1016/j.jviromet.2014.01.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2013] [Revised: 12/02/2013] [Accepted: 01/09/2014] [Indexed: 10/25/2022]
Abstract
The objective of this study was to compare three nucleic acid extraction and reverse transcription-quantitative polymerase chain reaction (RT-qPCR) approaches for norovirus (NoV) detection in drinking water with respect to performance, costs, and analysis time. The approaches evaluated were: (A) an approach that utilizes the QIAamp DNA Blood Mini Kit and multiplex primers and probes for detection; (B) a procedure which includes the NucliSENS Magnetic Extraction Kit and other components of a proposed European Union standard method for NoV detection in foods; and (C) a commercialized assay which uses NucliSENS extraction and Cepheid SmartCycler® technologies. Each approach was evaluated by most probable number (MPN) analysis for detection of GI.1 and GII.4 NoVs from human stool. Furthermore, recoveries of spiked primary effluent in tap water concentrates were compared for each approach. Few significant differences were observed between approaches with regard to performance. However, Approach C was the most time consuming and expensive to perform. This research presents a case study of how molecular-based approaches for detection of NoVs can be compared and how various factors may play a role in which approach laboratories choose to employ.
Collapse
Affiliation(s)
- Shannon M Griffin
- U.S. Environmental Protection Agency, National Exposure Research Laboratory, 26W. Martin Luther King Dr., Cincinnati, OH 45268, USA.
| | - Nichole E Brinkman
- U.S. Environmental Protection Agency, National Exposure Research Laboratory, 26W. Martin Luther King Dr., Cincinnati, OH 45268, USA
| | - Elizabeth J Hedrick
- U.S. Environmental Protection Agency, Office of Water, Water Security Division, 26W. Martin Luther King Dr., Cincinnati, OH 45268, USA
| | - Eric R Rhodes
- U.S. Environmental Protection Agency, National Exposure Research Laboratory, 26W. Martin Luther King Dr., Cincinnati, OH 45268, USA
| | - G Shay Fout
- U.S. Environmental Protection Agency, National Exposure Research Laboratory, 26W. Martin Luther King Dr., Cincinnati, OH 45268, USA
| |
Collapse
|
25
|
De Keuckelaere A, Stals A, Baert L, Uyttendaele M. Performance of Two Real-Time RT-PCR Assays for the Quantification of GI and GII Noroviruses and Hepatitis A Virus in Environmental Water Samples. FOOD ANAL METHOD 2013. [DOI: 10.1007/s12161-013-9647-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
26
|
Gentry-Shields J, Stewart JR. Similar concentration and extraction recoveries allow for use of turnip crinkle virus as a process control for enteroviruses in water. J Virol Methods 2013; 189:250-7. [PMID: 23466632 DOI: 10.1016/j.jviromet.2013.02.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2012] [Revised: 02/21/2013] [Accepted: 02/25/2013] [Indexed: 01/30/2023]
Abstract
Enteric viruses are etiological agents of waterborne disease that may be detected using molecular techniques such as PCR. However, processing water samples in preparation for PCR typically involves concentration of samples and extraction of nucleic acids, steps that have low and variable recovery efficiencies. This study evaluated a plant virus, turnip crinkle virus (TCV), for its ability to serve as a process control for human enteroviruses during concentration and extraction procedures. Enteroviruses and TCV have similar sizes and morphologies, and both contain single stranded, positive-sense RNA genomes. Results from the study demonstrate that the tested viruses experience similar losses during sample processing. Virus recoveries averaged 0.03% for EV and 0.02% for TCV from DI water, and 0.004% for EV and 0.009% for TCV from a creek sample. Surface water and wastewater samples from around the U.S. were evaluated for the presence of TCV to ensure the virus is not present in environmental samples. All were negative. With similar recovery efficiencies to EV, TCV may be a suitable process control for enteroviruses in environmental water samples in the U.S. Use of process controls as proposed in this study would allow better detection and quantitation methods to be employed in water quality monitoring.
Collapse
Affiliation(s)
- Jennifer Gentry-Shields
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC 27599-7431, USA.
| | | |
Collapse
|