1
|
Nam NN, Trinh TND, Do HDK, Phan TB, Trinh KTL, Lee NY. Advances and Opportunities of luminescence Nanomaterial for bioanalysis and diagnostics. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 327:125347. [PMID: 39486236 DOI: 10.1016/j.saa.2024.125347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 04/15/2024] [Accepted: 10/24/2024] [Indexed: 11/04/2024]
Abstract
Luminescence nanomaterials (LNMs) have recently received great attention in biological analysis and sensing owing to their key advances in easy design and functionalization with high photostability, luminescence stability, low autofluorescence, and multiphoton capacity. The number of publications surrounding LNMs for biological applications has grown rapidly. LNMs based on Stokes and anti-Stokes shifts are powerful tools for biological analysis. Especially, unique properties of anti-Stokes luminescence such as upconversion nanoparticles (UCNPs) with an implementation strategy to use longer-wavelength excitation sources such as near-infrared (NIR) light can depth penetrate to biological tissue for bioanalysis and bioimaging. We observed that the LNMs-based metal-organic frameworks (MOFs) have been developed and paid attention to the field of bioimaging and luminescence-based sensors, because of their structural flexibility, and multifunctionality for the encapsulation of luminophores. This article provides an overview of innovative LNMs such as quantum dots (QDs), UCNPs, and LMOFs. A brief summary of recent progress in design strategies and applications of LNMs including pH and temperature sensing in biologically responsive platforms, pathogen detection, molecular diagnosis, bioimaging, photodynamic, and radiation therapy published within the past three years is highlighted. It was found that the integrated nanosystem of lab-on-a-chip (LOC) with nanomaterials was rapidly widespread and erupting in interest after the COVID-19 pandemic. The simple operation and close processes of the integration nanosystem together with the optimized size and low energy and materials consumption of biochips and devices allow their trend study and application to develop portable and intelligent diagnostics tools. The last part of this work is the introduction of the utilization use of LNMs in LOC applications in terms of microfluidics and biodevices.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Thi Ngoc Diep Trinh
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City 72820, Vietnam
| | - Thang Bach Phan
- Center for Innovative Materials and Architectures (INOMAR), Ho Chi Minh City 72820, VietNam; Vietnam National University, Ho Chi Minh City 72820, VietNam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
2
|
Liang J, Liu X, Liu Z, Xu X, Sun Y, Chen Y, Xiao R, Wang Y. Nanozymes featuring a mesoporous silica shell for rapid enrichment and ultrasensitive lateral flow immunoassay of influenza A. Anal Chim Acta 2025; 1335:343474. [PMID: 39643324 DOI: 10.1016/j.aca.2024.343474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2024] [Revised: 11/19/2024] [Accepted: 11/21/2024] [Indexed: 12/09/2024]
Abstract
BACKGROUND Respiratory illnesses stemming from influenza A viruses represent a significant worldwide health concern. There is an immediate need for a rapid and sensitive method to detect influenza A viruses early, without requiring extra equipment. RESULTS Here, we established a lateral flow immunoassay (LFIA) for the detection of influenza A (Flu A) using a "three-in-one" multifunctional mesoporous Fe3O4@SiO2@Pt nanozymes (Fe3O4@MSiO2@Pt NZs) with excellent magnetic separation properties, colorimetric, and peroxidase-like (POD-like) activities. Effective enrichment of target Flu A in complex samples as well as greater loading of Pt particles by mesoporous structures with large specific surface area to enhance POD-like activity can significantly improve the detection sensitivity of the LFIA. After colorimetric amplification by Fe3O4@MSiO2@Pt tags catalysis, the qualitative and quantitative results of detection for Flu A nucleoprotein (Flu A-NP) were 0.01 and 0.0089 ng mL-1, respectively. This indicated a sensitivity approximately 100 times greater than commercially available colloidal Au nanoparticle (AuNP)-based LFIA strips. For detection of inactivated H1N1 virus, quantification can be as low as 33 copies mL-1. Moreover, it demonstrated high accuracy in pharyngeal swab sample simulation experiments. SIGNIFICANCE Therefore, the proposed platform based on Fe3O4@MSiO2@Pt NZs-LFIA offered a promising approach for point-of-care testing (POCT), enabling rapid and ultrasensitive diagnosis of Flu A.
Collapse
Affiliation(s)
- Jing Liang
- Department of Clinical Laboratory, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China; State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China
| | - Xiaoxian Liu
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China
| | - Zhenzhen Liu
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China
| | - Xuanming Xu
- Department of Clinical Laboratory, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China
| | - Yinuo Sun
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China
| | - Yuan Chen
- Department of Clinical Laboratory, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China
| | - Rui Xiao
- State Key Laboratory of Pathogen and Biosecurity, Academy of Military Medical Sciences, Beijing, 100071, China.
| | - Yajie Wang
- Department of Clinical Laboratory, Beijing Ditan Hospital, Capital Medical University, Beijing, 100015, China.
| |
Collapse
|
3
|
Shalileh F, Shamani N, Golbashy M, Dadmehr M, Hosseini M. Synergistic applications of quantum dots and magnetic nanomaterials in pathogen detection: a comprehensive review. NANOTECHNOLOGY 2024; 36:052002. [PMID: 39413804 DOI: 10.1088/1361-6528/ad8751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2024] [Accepted: 10/16/2024] [Indexed: 10/18/2024]
Abstract
The rapid and accurate detection of pathogens is crucial for effective disease prevention and management in healthcare, food safety, and environmental monitoring. While conventional pathogen detection methods like culture-based techniques and PCR are sensitive and selective, they are often time-consuming, require skilled operators, and are not suitable for point-of-care or on-site testing. To address these limitations, innovative sensor technologies have emerged that leverage the unique properties of nanomaterials. Quantum dots (QDs) and magnetic nanomaterials are two classes of nanomaterials that have shown particular promise for pathogen sensing. This review comprehensively examines the synergistic applications of QDs and magnetic nanomaterials for detecting bacteria, viruses, phages, and parasites.
Collapse
Affiliation(s)
- Farzaneh Shalileh
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Negin Shamani
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| | - Mohammad Golbashy
- Department of Plant Production and Genetics Engineering, College of Agriculture, Agricultural Sciences and Natural Resources, University of Khuzestan, Mollasani, Iran
| | - Mehdi Dadmehr
- Department of Biology, Payame Noor University, Tehran, Iran
| | - Morteza Hosseini
- Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, Iran
| |
Collapse
|
4
|
Zhou Y, Du W, Chen Y, Li L, Xiao X, Xu Y, Yang W, Hu X, Wang B, Zhang J, Jiang Q, Wang Y. Pathogen detection via inductively coupled plasma mass spectrometry analysis with nanoparticles. Talanta 2024; 277:126325. [PMID: 38833906 DOI: 10.1016/j.talanta.2024.126325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 04/24/2024] [Accepted: 05/24/2024] [Indexed: 06/06/2024]
Abstract
Infections caused by viruses and bacteria pose a significant threat to global public health, emphasizing the critical importance of timely and precise detection methods. Inductively coupled plasma mass spectrometry (ICP-MS), a contemporary approach for pathogen detection, offers distinct advantages such as high sensitivity, a wide linear range, and multi-index capabilities. This review elucidates the underexplored application of ICP-MS in conjunction with functional nanoparticles (NPs) for the identification of viruses and bacteria. The review commences with an elucidation of the underlying principles, procedures, target pathogens, and NP requirements for this innovative approach. Subsequently, a thorough analysis of the advantages and limitations associated with these techniques is provided. Furthermore, the review delves into a comprehensive examination of the challenges encountered when utilizing NPs and ICP-MS for pathogen detection, culminating in a forward-looking assessment of the potential pathways for advancement in this domain. Thus, this review contributes novel perspectives to the field of pathogen detection in biomedicine by showcasing the promising synergy of ICP-MS and NPs.
Collapse
Affiliation(s)
- Yujie Zhou
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Wenli Du
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Yuzuo Chen
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu, Sichuan, 610041, China
| | - Lei Li
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Xuanyu Xiao
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Yuanyuan Xu
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Wenjuan Yang
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, Sichuan, 610041, China
| | - Xuefeng Hu
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu, Sichuan, 610041, China
| | - Baoning Wang
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu, Sichuan, 610041, China.
| | - Jieyu Zhang
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China.
| | - Qing Jiang
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, 29 Wangjiang Road, Chengdu, Sichuan, 610065, China
| |
Collapse
|
5
|
Pilati V, Salvador M, Fraile LB, Marqués-Fernández JL, Gomes da Silva F, Fadel M, Antón RL, Morales MDP, Martinez-García JC, Rivas M. Mn-ferrite nanoparticles as promising magnetic tags for radiofrequency inductive detection and quantification in lateral flow assays. NANOSCALE ADVANCES 2024; 6:4247-4258. [PMID: 39114157 PMCID: PMC11302204 DOI: 10.1039/d4na00445k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Accepted: 07/05/2024] [Indexed: 08/10/2024]
Abstract
Lateral flow assays are low-cost point-of-care devices that are stable, easy to use, and provide quick results. They are mostly used as qualitative screening tests to detect biomarkers for several diseases. Quantification of the biomarkers is sometimes desirable but challenging to achieve. Magnetic nanoparticles can be used as tags, providing both visual and magnetic signals that can be detected and quantified by magnetic sensors. In the present work, we synthesized superparamagnetic MnFe2O4 nanoparticles using the hydrothermal coprecipitation route. MnFe2O4 presents low magnetic anisotropy and high saturation magnetization, resulting in larger initial magnetic susceptibility, which is crucial for optimizing the signal in inductive sensors. We functionalized the coprecipitated nanoparticles with citric acid to achieve colloidal stability in a neutral pH and to provide carboxyl groups to their surface to bioconjugate with biomolecules, such as proteins and antibodies. The nanomaterials were characterized by several techniques, and we correlated their magnetic properties with their sensitivity and resolution for magnetic detection in radiofrequency inductive sensors. We considered the NeutrAvidin/biotin model of biorecognition to explore their potential as magnetic labels in lateral flow assays. Our results show that MnFe2O4 nanoparticles are more sensitive to inductive detection than magnetite nanoparticles, the most used nanotags in magnetic lateral flow assays. These nanoparticles present high potential as magnetic tags for the development of sensitive lateral flow immunoassays for detecting and quantifying biomarkers.
Collapse
Affiliation(s)
- Vanessa Pilati
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
- Complex Fluids Group, Instituto de Física & Faculdade UnB - Planaltina, Universidade de Brasília Brasília 70910-900 Brazil
| | - María Salvador
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
- Departamento de Nanociencia y Nanotecnología, Instituto de Ciencia de Materiales de Madrid (ICMM) Madrid 28049 Spain
| | - Leyre Bei Fraile
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
| | | | - Franciscarlos Gomes da Silva
- Complex Fluids Group, Instituto de Física & Faculdade UnB - Planaltina, Universidade de Brasília Brasília 70910-900 Brazil
| | - Mona Fadel
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
| | - Ricardo López Antón
- Instituto Regional de Investigación Científica Aplicada (IRICA) and Departamento de Física Aplicada, Universidad de Castilla-La Mancha Ciudad Real Spain
| | - María Del Puerto Morales
- Departamento de Nanociencia y Nanotecnología, Instituto de Ciencia de Materiales de Madrid (ICMM) Madrid 28049 Spain
| | - José Carlos Martinez-García
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
- Instituto Universitario de Tecnología Industrial de Asturias (IUTA) Gijón 33203 Spain
| | - Montserrat Rivas
- Departamento de Física, Campus de Viesques, Universidad de Oviedo Gijón 33204 Spain
- Instituto Universitario de Tecnología Industrial de Asturias (IUTA) Gijón 33203 Spain
| |
Collapse
|
6
|
Gao F, Ye S, Huang L, Gu Z. A nanoparticle-assisted signal-enhancement technique for lateral flow immunoassays. J Mater Chem B 2024; 12:6735-6756. [PMID: 38920348 DOI: 10.1039/d4tb00865k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/27/2024]
Abstract
Lateral flow immunoassay (LFIA), an affordable and rapid paper-based detection technology, is employed extensively in clinical diagnosis, environmental monitoring, and food safety analysis. The COVID-19 pandemic underscored the validity and adoption of LFIA in performing large-scale clinical and public health testing. The unprecedented demand for prompt diagnostic responses and advances in nanotechnology have fueled the rise of next-generation LFIA technologies. The utilization of nanoparticles to amplify signals represents an innovative approach aimed at augmenting LFIA sensitivity. This review probes the nanoparticle-assisted amplification strategies in LFIA applications to secure low detection limits and expedited response rates. Emphasis is placed on comprehending the correlation between the physicochemical properties of nanoparticles and LFIA performance. Lastly, we shed light on the challenges and opportunities in this prolific field.
Collapse
Affiliation(s)
- Fang Gao
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
| | - Shaonian Ye
- Institute of Energy Materials Science, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China
| | - Lin Huang
- Department of Clinical Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China.
- Shanghai Institute of Thoracic Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China
| | - Zhengying Gu
- Department of Clinical Laboratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China.
- Shanghai Institute of Thoracic Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200030, China
| |
Collapse
|
7
|
Pan X, Wang J, Zhang K, Sun P, Shi J, Zhi J, Cai Z, Li Z, Wang D, Tong B, Dong Y. Differential detection of H1N1 virus spiker proteins by two hexaphenylbutadiene isomers based on size-matching principle. Anal Chim Acta 2024; 1299:342452. [PMID: 38499411 DOI: 10.1016/j.aca.2024.342452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 02/05/2024] [Accepted: 03/05/2024] [Indexed: 03/20/2024]
Abstract
As one of the high pathogenic influenza viruses, H1N1 virus easily induces to serious diseases, even leading to death. To date, all detection methods for H1N1 virus had shortcomings, including high equipment cost, time consumption, and etc. Therefore, a novel detection method should be established to achieve more convenient, rapid, and low-cost detection. In this work, an isomer of HPBmN-I with aggregation-induced emission characteristic was firstly synthesized on the basis of our previous reported HPBpN-I. The results showed that HPBmN-I only selectively binds to N1 in the presence of H1, while HPBpN-I can exhibit total fluorescence response to H1 and N1 in H1/N1 mixture. The limited of detection (LOD) of HPBmN-I to N1 was estimated to be 20.82 ng/mL in normal saline (NS) according to the IUPAC-based approach. The simulation calculations based on molecular docking revealed that four HPBmN-I molecules combine well with the hydrophobic cavity of N1 and achieve the fluorescence enhancement due to size matching with each other. The combination of HPBpN-I and HPBmN-I as probes was successfully used to quantitatively detect H1 and N1 in real H1N1 virus. Compared to enzyme-linked immunosorbent assay (ELISA) method, the established method not only showed the same detection accuracy but also had the advantages of real-time, ease of preparation, and low-cost, demonstrating potential market prospects.
Collapse
Affiliation(s)
- Xiaoling Pan
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China; Department of Nanomedicine & Shanghai Key Lab of Cell Engineering, Naval Medical University, Shanghai, 200433, China
| | - Jian Wang
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Kai Zhang
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Peng Sun
- Advanced Research Institute of Multidisciplinary Science, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Jianbing Shi
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Junge Zhi
- School of Chemistry, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Zhengxu Cai
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China
| | - Zi Li
- National Institute for Viral Disease Control and Prevention, Collaboration Innovation Center for Diagnosis and Treatment of Infectious Diseases, Chinese Center for Disease Control and Prevention, Key Laboratory for Medical Virology, National Health and Family Planning Commission, Beijing, 102206, China
| | - Dayan Wang
- National Institute for Viral Disease Control and Prevention, Collaboration Innovation Center for Diagnosis and Treatment of Infectious Diseases, Chinese Center for Disease Control and Prevention, Key Laboratory for Medical Virology, National Health and Family Planning Commission, Beijing, 102206, China
| | - Bin Tong
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China.
| | - Yuping Dong
- Beijing Key Laboratory of Construction Tailorable Advanced Functional Materials and Green Applications, School of Material Science & Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Beijing, 100081, China.
| |
Collapse
|
8
|
Kim MJ, Haizan I, Ahn MJ, Park DH, Choi JH. Recent Advances in Lateral Flow Assays for Viral Protein Detection with Nanomaterial-Based Optical Sensors. BIOSENSORS 2024; 14:197. [PMID: 38667190 PMCID: PMC11048458 DOI: 10.3390/bios14040197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 04/12/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024]
Abstract
Controlling the progression of contagious diseases is crucial for public health management, emphasizing the importance of early viral infection diagnosis. In response, lateral flow assays (LFAs) have been successfully utilized in point-of-care (POC) testing, emerging as a viable alternative to more traditional diagnostic methods. Recent advancements in virus detection have primarily leveraged methods such as reverse transcription-polymerase chain reaction (RT-PCR), reverse transcription-loop-mediated isothermal amplification (RT-LAMP), and the enzyme-linked immunosorbent assay (ELISA). Despite their proven effectiveness, these conventional techniques are often expensive, require specialized expertise, and consume a significant amount of time. In contrast, LFAs utilize nanomaterial-based optical sensing technologies, including colorimetric, fluorescence, and surface-enhanced Raman scattering (SERS), offering quick, straightforward analyses with minimal training and infrastructure requirements for detecting viral proteins in biological samples. This review describes the composition and mechanism of and recent advancements in LFAs for viral protein detection, categorizing them into colorimetric, fluorescent, and SERS-based techniques. Despite significant progress, developing a simple, stable, highly sensitive, and selective LFA system remains a formidable challenge. Nevertheless, an advanced LFA system promises not only to enhance clinical diagnostics but also to extend its utility to environmental monitoring and beyond, demonstrating its potential to revolutionize both healthcare and environmental safety.
Collapse
Affiliation(s)
- Min Jung Kim
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
| | - Izzati Haizan
- Department of Bioprocess Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea;
| | - Min Ju Ahn
- Department of Biotechnology, Jeonbuk National University, 79 Gobongro, Iksan-si 54596, Jeollabuk-do, Republic of Korea;
| | - Dong-Hyeok Park
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
| | - Jin-Ha Choi
- School of Chemical Engineering, Clean Energy Research Center, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea; (M.J.K.); (D.-H.P.)
- Department of Bioprocess Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si 54896, Jeollabuk-do, Republic of Korea;
| |
Collapse
|
9
|
Yasir M, Mishra R, Tripathi AS, Maurya RK, Shahi A, Zaki MEA, Al Hussain SA, Masand VH. Theranostics: a multifaceted approach utilizing nano-biomaterials. DISCOVER NANO 2024; 19:35. [PMID: 38407670 PMCID: PMC10897124 DOI: 10.1186/s11671-024-03979-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 02/19/2024] [Indexed: 02/27/2024]
Abstract
Biomaterials play a vital role in targeting therapeutics. Over the years, several biomaterials have gained wide attention in the treatment and diagnosis of diseases. Scientists are trying to make more personalized treatments for different diseases, as well as discovering novel single agents that can be used for prognosis, medication administration, and keeping track of how a treatment works. Theranostics based on nano-biomaterials have higher sensitivity and specificity for disease management than conventional techniques. This review provides a concise overview of various biomaterials, including carbon-based materials like fullerenes, graphene, carbon nanotubes (CNTs), and carbon nanofibers, and their involvement in theranostics of different diseases. In addition, the involvement of imaging techniques for theranostics applications was overviewed. Theranostics is an emerging strategy that has great potential for enhancing the accuracy and efficacy of medicinal interventions. Despite the presence of obstacles such as disease heterogeneity, toxicity, reproducibility, uniformity, upscaling production, and regulatory hurdles, the field of medical research and development has great promise due to its ability to provide patients with personalised care, facilitate early identification, and enable focused treatment.
Collapse
Affiliation(s)
- Mohammad Yasir
- Amity Institute of Pharmacy, Lucknow, Amity University Uttar Pradesh, Sector125, Noida, 201313, India.
| | - Ratnakar Mishra
- Amity Institute of Pharmacy, Lucknow, Amity University Uttar Pradesh, Sector125, Noida, 201313, India
| | | | - Rahul K Maurya
- Amity Institute of Pharmacy, Lucknow, Amity University Uttar Pradesh, Sector125, Noida, 201313, India
| | - Ashutosh Shahi
- Amity Institute of Pharmacy, Lucknow, Amity University Uttar Pradesh, Sector125, Noida, 201313, India
| | - Magdi E A Zaki
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University, Riyadh, 13318, Saudi Arabia.
| | - Sami A Al Hussain
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University, Riyadh, 13318, Saudi Arabia
| | - Vijay H Masand
- Department of Chemistry, Vidya Bharati Mahavidyalaya, Amravati, Maharashtra, India
| |
Collapse
|
10
|
Wang F, Li X, Liu Z, Zhao X, Zhao C, Hou G, Liu Q, Liu X. A Magnetic-Optical Triple-Mode Lateral Flow Immunoassay for Sensitive and Rapid Detection of Respiratory Adenovirus. Anal Chem 2024; 96:2059-2067. [PMID: 38258754 DOI: 10.1021/acs.analchem.3c04696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2024]
Abstract
Human respiratory adenovirus (ADV) is a highly infectious respiratory virus with potential for pandemics. There are currently no specific drugs to treat ADV worldwide, so early rapid detection of ADV infection is essential. In this study, we developed an innovative magnetic-optical triple-mode lateral flow immunoassay (LFIA) using magnetic quantum dots as immunomarkers. This novel approach addresses the need for rapid and accurate ADV detection, allowing for multimodal quantitative/semiquantitative analysis of magnetic, fluorescent, and visible signals within a mere 15 min. The lower limit of detection (LOD) for magnetic, fluorescent, and visual signals was determined to be 5.6 × 103, 1.2 × 103, and 1.95 × 104 copies/mL, respectively. The detection range for ADV using this approach was 1.2 × 103-5 × 107 copies/mL. Additionally, semiquantitative analysis, which is user-friendly and does not necessitate specialized equipment, was successfully implemented. Notably, seven respiratory viruses showed no cross-reactivity with the generated LFIA test strips. The intrabatch repeatability exhibited a coefficient of variation (CV) of less than 5%, while the interbatch repeatability had a CV of less than 15%. Furthermore, recovery values ranged from 95% to 106.8% for samples analyzed concurrently with dual signals at the same spiking concentration. The assay developed in this study boasts a wide detection range and exceptional sensitivity and specificity. This technique is exceptionally well-suited for on-site rapid detection, with the potential for personal self-testing and early ADV infection diagnosis. Its versatility extends to a broad array of application scenarios.
Collapse
Affiliation(s)
- Fei Wang
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou 121001, PR China
- Bioinformatics Center of Academy of Military Medical Sciences, Beijing 100850, PR China
| | - Xiaoyan Li
- Bioinformatics Center of Academy of Military Medical Sciences, Beijing 100850, PR China
| | - Zhining Liu
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou 121001, PR China
| | - Xin Zhao
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou 121001, PR China
| | - Changxu Zhao
- Bioinformatics Center of Academy of Military Medical Sciences, Beijing 100850, PR China
| | - Guangzheng Hou
- Bioinformatics Center of Academy of Military Medical Sciences, Beijing 100850, PR China
| | - Qiqi Liu
- Bioinformatics Center of Academy of Military Medical Sciences, Beijing 100850, PR China
| | - Xin Liu
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou 121001, PR China
- Jinzhou Medical University Huludao Central Hospital Teaching Base, Huludao 125001,PR China
| |
Collapse
|
11
|
Wang K, Liu X, Liang X, Jiang Y, Wen CY, Zeng J. Near-Infrared Responsive Ag@Au Nanoplates with Exceptional Stability for Highly Sensitive Colorimetric and Photothermal Dual-Mode Lateral Flow Immunoassay. Anal Chem 2024. [PMID: 38317503 DOI: 10.1021/acs.analchem.3c05787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2024]
Abstract
Lateral flow immunoassay (LFIA) has played a vital role in point-of-care (POC) testing on account of its simplicity, rapidity, and low cost. However, the low sensitivity and difficulty of quantitation limit its further development. Sensitive markers with new detection modes are being developed to dramatically improve LFIA's performance. Herein, a ligand-complex approach was proposed to uniformly coat a thin layer of Au onto Ag triangular nanoplates (Ag TNPs) without etching the Ag cores, which not only retain the unique optical properties from Ag TNPs but also acquire the surface stability and biocompatibility of gold. The localized surface plasmon resonance absorption of these Ag@Au TNPs could be finely adjusted from visible (550 nm) to the second near-infrared region (NIR-II) (1100 nm), and even longer, by simply adjusting the ratio between edge length and thickness. Utilizing the Ag@Au TNPs as new markers for LFIA, a highly sensitive colorimetric and photothermal dual-mode detection of the SARS-CoV-2 nucleocapsid protein was achieved with a very low background. The Ag@Au TNPs showed an exceedingly high photothermal conversion efficiency of 61.4% (ca. 2 times higher than that of Au nanorods), endowing the LFIA method with a low photothermal detection limit (40 pg/mL), which was 25-fold lower than that of the colorimetric results. The generality of the method was further verified by the sensitive and accurate analysis of cardiac troponin I (cTnI). This method is robust, reproducible, and highly specific and has been successfully applied to SARS-COV-2 detection in 35 clinical samples with satisfactory results, demonstrating its potential for POC applications.
Collapse
Affiliation(s)
- Kun Wang
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China
| | - Xiaohui Liu
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China
| | - Xinyi Liang
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China
| | - Yongzhong Jiang
- Hubei Provincial Center for Disease Control and Prevention, Wuhan 430065, China
| | - Cong-Ying Wen
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China
| | - Jingbin Zeng
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China
| |
Collapse
|
12
|
Cui H, Pan W, Li T, Shen X, Chang Y, Pang W, Duan X. Rapid purification and enrichment of viral particles using self-propelled micromotors. NANOSCALE 2023; 15:17105-17112. [PMID: 37850316 DOI: 10.1039/d3nr02812g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/19/2023]
Abstract
Virus infections remain one of the principal causes of morbidity and mortality worldwide. The current gold standard approach for diagnosing pathogens requires access to reverse transcription-polymerase chain reaction (RT-PCR) technology. However, separation and enrichment of the targets from complex and diluted samples remains a major challenge. In this work, we proposed a micromotor-based sample preparation concept for the efficient separation and concentration of target viral particles before PCR. The micromotors are functionalized with antibodies with a 3D polymer linker and are capable of self-propulsion by the catalytic generation of oxygen bubbles for selective and positive virus enrichment. This strategy significantly improves the enrichment efficiency and recovery rate of virus (up to 80% at 104 tu mL-1 in a 1 mL volume within just 6 min) without external mixing equipment. The method allows the Ct value in regular PCR tests to appear 6-7 cycles earlier and a detection limit of 1 tu mL-1 for the target virus from swap samples. A point-of-need test kit is designed based on the micromotors which can be readily applied to pretreat a large volume of samples.
Collapse
Affiliation(s)
- Haipeng Cui
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Wenwei Pan
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Tiechuan Li
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Xiaotian Shen
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Ye Chang
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Wei Pang
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| | - Xuexin Duan
- State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, P.R. China
- College of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, P.R. China
| |
Collapse
|
13
|
Song SW, Gupta R, Jothilingam N, Qian X, Gu Y, Lee VV, Sapanel Y, Allen DM, Wong JEL, MacAry P, Ho D, Blasiak A. SHEAR saliva collection device augments sample properties for improved analytical performance. Bioeng Transl Med 2023; 8:e10490. [PMID: 38023718 PMCID: PMC10658560 DOI: 10.1002/btm2.10490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 12/12/2022] [Accepted: 12/29/2022] [Indexed: 01/19/2023] Open
Abstract
Despite being a convenient clinical substrate for biomonitoring, saliva's widespread utilization has not yet been realized. The non-Newtonian, heterogenous, and highly viscous nature of saliva complicate the development of automated fluid handling processes that are vital for accurate diagnoses. Furthermore, conventional saliva processing methods are resource and/or time intensive precluding certain testing capabilities, with these challenges aggravated during a pandemic. The conventional approaches may also alter analyte structure, reducing application opportunities in point-of-care diagnostics. To overcome these challenges, we introduce the SHEAR saliva collection device that mechanically processes saliva, in a rapid and resource-efficient way. We demonstrate the device's impact on reducing saliva's viscosity, improving sample's uniformity, and increasing diagnostic performance of a COVID-19 rapid antigen test. Additionally, a formal user experience study revealed generally positive comments. SHEAR saliva collection device may support realization of the saliva's potential, particularly in large-scale and/or resource-limited settings for global and community diagnostics.
Collapse
Affiliation(s)
- Shang Wei Song
- The N.1 Institute for Health (N.1), National University of SingaporeSingaporeSingapore
| | - Rashi Gupta
- Life Sciences Institute, National University of SingaporeSingaporeSingapore
- Department of Microbiology and ImmunologyYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - Niharika Jothilingam
- The N.1 Institute for Health (N.1), National University of SingaporeSingaporeSingapore
| | - Xinlei Qian
- Life Sciences Institute, National University of SingaporeSingaporeSingapore
- Department of Microbiology and ImmunologyYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - Yue Gu
- Life Sciences Institute, National University of SingaporeSingaporeSingapore
| | - V Vien Lee
- The N.1 Institute for Health (N.1), National University of SingaporeSingaporeSingapore
- The Institute for Digital Medicine (WisDM), Yong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - Yoann Sapanel
- The Institute for Digital Medicine (WisDM), Yong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - David Michael Allen
- Department of MedicineYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
- Division of Infectious DiseasesNational University HospitalSingaporeSingapore
| | - John Eu Li Wong
- Department of MedicineYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
- Department of Haematology‐OncologyNational University Cancer Institute, National University HospitalSingaporeSingapore
| | - Paul MacAry
- Life Sciences Institute, National University of SingaporeSingaporeSingapore
- Department of Microbiology and ImmunologyYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - Dean Ho
- The N.1 Institute for Health (N.1), National University of SingaporeSingaporeSingapore
- The Institute for Digital Medicine (WisDM), Yong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
- Department of Biomedical EngineeringCollege of Design and Engineering, National University of SingaporeSingaporeSingapore
- Department of PharmacologyYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| | - Agata Blasiak
- The N.1 Institute for Health (N.1), National University of SingaporeSingaporeSingapore
- The Institute for Digital Medicine (WisDM), Yong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
- Department of Biomedical EngineeringCollege of Design and Engineering, National University of SingaporeSingaporeSingapore
- Department of PharmacologyYong Loo Lin School of Medicine, National University of SingaporeSingaporeSingapore
| |
Collapse
|
14
|
Zhu X, Kim TY, Kim SM, Luo K, Lim MC. Recent Advances in Biosensor Development for the Detection of Viral Particles in Foods: A Comprehensive Review. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2023; 71:15942-15953. [PMID: 37862248 DOI: 10.1021/acs.jafc.3c05166] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
Viral foodborne diseases cause serious harm to human health and the economy. Rapid, accurate, and convenient approaches for detecting foodborne viruses are crucial for preventing diseases. Biosensors integrating electrochemical and optical properties of nanomaterials have emerged as effective tools for the detection of viruses in foods. However, they still face several challenges, including substantial sample preparation and relatively poor sensitivity due to complex food matrices, which limit their field applications. Hence, the purpose of this review is to provide an overview of recent advances in biosensing techniques, including electrochemical, SERS-based, and colorimetric biosensors, for detecting viral particles in food samples, with emerging techniques for extraction/concentration of virus particles from food samples. Moreover, the principle, design, and advantages/disadvantages of each biosensing method are comprehensively described. This review covers the recent development of rapid and sensitive biosensors that can be used as new standards for monitoring food safety and food quality in the food industry.
Collapse
Affiliation(s)
- Xiaoning Zhu
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, People's Republic of China
| | - Tai-Yong Kim
- Research Group of Food Safety and Distribution, Korea Food Research Institute (KFRI), Wanju-gun, Jeollabuk-do 55365, Republic of Korea
| | - Se-Min Kim
- Research Group of Food Safety and Distribution, Korea Food Research Institute (KFRI), Wanju-gun, Jeollabuk-do 55365, Republic of Korea
- Department of Food Science and Technology, Jeonbuk National University, Jeonju-si, Jeollabuk-do 54896, Republic of Korea
| | - Ke Luo
- College of Food Science and Engineering, Ocean University of China, Qingdao, Shandong Province 266003, People's Republic of China
| | - Min-Cheol Lim
- Research Group of Food Safety and Distribution, Korea Food Research Institute (KFRI), Wanju-gun, Jeollabuk-do 55365, Republic of Korea
- Department of Food Biotechnology, Korea University of Science and Technology, Daejeon-si 34113, Republic of Korea
| |
Collapse
|
15
|
Kim JH, Jeong HS, Hwang J, Kweon DH, Choi CH, Park JP. Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus. ACS APPLIED MATERIALS & INTERFACES 2023. [PMID: 37903089 DOI: 10.1021/acsami.3c14470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/01/2023]
Abstract
Influenza viruses are known to cause pandemic flu outbreaks through both inter-human and animal-to-human transmissions. Therefore, the rapid and accurate detection of such pathogenic viruses is crucial for effective pandemic control. Here, we introduce a novel sensor based on affinity peptide-immobilized hydrogel microspheres for the selective detection of influenza A virus (IAV) H3N2. To enhance the binding affinity performance, we identified novel affinity peptides using phage display and further optimized their design. The functional hydrogel microspheres were constructed using the drop microfluidic technique, employing a structure composed of natural (chitosan) and synthetic (poly(ethylene glycol) diacrylate and PEG 6 kDa) polymers with the activation of azadibenzocyclooctyne for the subsequent click chemistry reaction. The binding peptide-immobilized hydrogel microsphere (BP-Hyd) was characterized by field emission scanning electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy and exhibited selective detection capability for the IAV H3N2. To capture the detected IAV H3N2, a Cy3-labeled IAV hemagglutinin antibody was utilized. By incorporating the affinity peptide with hydrogel microspheres, we achieved quantitative and selective detection of IAV H3N2 with a detection limit of 1.887 PFU mL-1. Furthermore, the developed suspension sensor exhibited excellent reproducibility and showed reusability potential. Our results revealed that the BP-Hyd-based fluorescence sensor platform could be feasibly employed to detect other pathogens because the virus-binding peptides can be easily replaced with other peptides through phage display, enabling selective and sensitive binding to different targets.
Collapse
Affiliation(s)
- Ji Hong Kim
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| | - Hye-Seon Jeong
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do 38541, Republic of Korea
| | - Jaehyeon Hwang
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Dae-Hyuk Kweon
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Republic of Korea
| | - Chang-Hyung Choi
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do 38541, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea
| |
Collapse
|
16
|
Dey MK, Iftesum M, Devireddy R, Gartia MR. New technologies and reagents in lateral flow assay (LFA) designs for enhancing accuracy and sensitivity. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:4351-4376. [PMID: 37615701 DOI: 10.1039/d3ay00844d] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
Lateral flow assays (LFAs) are a popular method for quick and affordable diagnostic testing because they are easy to use, portable, and user-friendly. However, LFA design has always faced challenges regarding sensitivity, accuracy, and complexity of the operation. By integrating new technologies and reagents, the sensitivity and accuracy of LFAs can be improved while minimizing the complexity and potential for false positives. Surface enhanced Raman spectroscopy (SERS), photoacoustic techniques, fluorescence resonance energy transfer (FRET), and the integration of smartphones and thermal readers can improve LFA accuracy and sensitivity. To ensure reliable and accurate results, careful assay design and validation, appropriate controls, and optimization of assay conditions are necessary. Continued innovation in LFA technology is crucial to improving the reliability and accuracy of rapid diagnostic testing and expanding its applications to various areas, such as food testing, water quality monitoring, and environmental testing.
Collapse
Affiliation(s)
- Mohan Kumar Dey
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Maria Iftesum
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Ram Devireddy
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| | - Manas Ranjan Gartia
- Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA 70803, USA.
| |
Collapse
|
17
|
Hong D, Jo EJ, Bang D, Jung C, Lee YE, Noh YS, Shin MG, Kim MG. Plasmonic Approach to Fluorescence Enhancement of Mesoporous Silica-Coated Gold Nanorods for Highly Sensitive Influenza A Virus Detection Using Lateral Flow Immunosensor. ACS NANO 2023; 17:16607-16619. [PMID: 37595106 DOI: 10.1021/acsnano.3c02651] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/20/2023]
Abstract
Rapid diagnostic tests based on the lateral flow immunoassay (LFI) enable early identification of viral infection, owing to simple interpretation, short turnaround time, and timely isolation of patients to minimize viral transmission among communities. However, the LFI system requires improvement in the detection sensitivity to match the accuracy of nucleic acid amplification tests. Fluorescence-based LFIs are more sensitive and specific than absorption-based LFIs, but their performance is significantly affected by fundamental issues related to the quantum yield and photobleaching of fluorophores. Metal-enhanced fluorescence (MEF), which is a plasmonic effect in the vicinity of metallic nanoparticles, can be an effective strategy to improve the detection sensitivity of fluorescence-based LFIs. The key factors for obtaining a strong plasmonic effect include the distance and spectral overlap of the metal and fluorophore in the MEF system. In this study, MEF probes were designed based on core-shell nanostructures employing a gold nanorod core, mesoporous silica shell, and cyanine 5 fluorophore. To optimize the efficiency of MEF probes incorporated on the LFI platform (MEF-LFI), we experimentally and theoretically investigated the distance dependence of plasmonic coupling between cyanine 5 and gold nanorods by adjusting the shell thickness, resulting in significant fluorescence enhancement. The proposed MEF-LFI enabled highly sensitive detection of influenza A virus (IAV) nucleocapsid protein with a detection limit of 0.52 pg mL-1 within 20 min and showed high specificity and accuracy for determining IAV clinical samples. Overall, our findings demonstrate the potential of this method as an effective tool for molecular diagnosis under emergency conditions.
Collapse
Affiliation(s)
- Donggu Hong
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science & Technology (GIST), 123 Cheomdangwagi-ro, Gwangju 61005, Republic of Korea
| | - Eun-Jung Jo
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science & Technology (GIST), 123 Cheomdangwagi-ro, Gwangju 61005, Republic of Korea
| | - Doyeon Bang
- College of AI Convergence, Chonnam National University, 77 Yongbong-ro, Gwangju 61186, Republic of Korea
- Korea Institute of Medical Microrobotics, 208 Cheomdangwagi-ro, Gwangju 61011, Republic of Korea
| | - Chaewon Jung
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science & Technology (GIST), 123 Cheomdangwagi-ro, Gwangju 61005, Republic of Korea
| | - Young Eun Lee
- Department of Laboratory Medicine, Chonnam National University Medical School and Chonnam National University Hwasun Hospital, 322 Seoyang-ro, Hwasun-eup, Hwasun-gun, Jeollanam-do 58128, Republic of Korea
| | - Yu-Seon Noh
- Nano Bio Research Center JBF, 123, Nanosandan-ro, Nam-Myun, Jangseong-gun, Jeollanam-do 57248, Republic of Korea
| | - Myung Geun Shin
- Department of Laboratory Medicine, Chonnam National University Medical School and Chonnam National University Hwasun Hospital, 322 Seoyang-ro, Hwasun-eup, Hwasun-gun, Jeollanam-do 58128, Republic of Korea
| | - Min-Gon Kim
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science & Technology (GIST), 123 Cheomdangwagi-ro, Gwangju 61005, Republic of Korea
| |
Collapse
|
18
|
Li H, Zhang Z, Gan L, Fan D, Sun X, Qian Z, Liu X, Huang Y. Signal Amplification-Based Biosensors and Application in RNA Tumor Markers. SENSORS (BASEL, SWITZERLAND) 2023; 23:s23094237. [PMID: 37177441 PMCID: PMC10180857 DOI: 10.3390/s23094237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2023] [Revised: 04/10/2023] [Accepted: 04/20/2023] [Indexed: 05/15/2023]
Abstract
Tumor markers are important substances for assessing cancer development. In recent years, RNA tumor markers have attracted significant attention, and studies have shown that their abnormal expression of post-transcriptional regulatory genes is associated with tumor progression. Therefore, RNA tumor markers are considered as potential targets in clinical diagnosis and prognosis. Many studies show that biosensors have good application prospects in the field of medical diagnosis. The application of biosensors in RNA tumor markers is developing rapidly. These sensors have the advantages of high sensitivity, excellent selectivity, and convenience. However, the detection abundance of RNA tumor markers is low. In order to improve the detection sensitivity, researchers have developed a variety of signal amplification strategies to enhance the detection signal. In this review, after a brief introduction of the sensing principles and designs of different biosensing platforms, we will summarize the latest research progress of electrochemical, photoelectrochemical, and fluorescent biosensors based on signal amplification strategies for detecting RNA tumor markers. This review provides a high sensitivity and good selectivity sensing platform for early-stage cancer research. It provides a new idea for the development of accurate, sensitive, and convenient biological analysis in the future, which can be used for the early diagnosis and monitoring of cancer and contribute to the reduction in the mortality rate.
Collapse
Affiliation(s)
- Haiping Li
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
- School of Pharmacy, Guangxi Medical University, Nanning 530021, China
| | - Zhikun Zhang
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Lu Gan
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Dianfa Fan
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Xinjun Sun
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Zhangbo Qian
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Xiyu Liu
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
| | - Yong Huang
- State Key Laboratory of Targeting Oncology, National Center for International Research of Bio-Targeting Theranostics, Guangxi Key Laboratory of Bio-Targeting Theranostics, Collaborative Innovation Center for Targeting Tumor Diagnosis and Therapy, Guangxi Medical University, Nanning 530021, China
- School of Pharmacy, Guangxi Medical University, Nanning 530021, China
| |
Collapse
|
19
|
GhaderiShekhiAbadi P, Irani M, Noorisepehr M, Maleki A. Magnetic biosensors for identification of SARS-CoV-2, Influenza, HIV, and Ebola viruses: a review. NANOTECHNOLOGY 2023; 34:272001. [PMID: 36996779 DOI: 10.1088/1361-6528/acc8da] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 03/29/2023] [Indexed: 06/19/2023]
Abstract
Infectious diseases such as novel coronavirus (SARS-CoV-2), Influenza, HIV, Ebola, etc kill many people around the world every year (SARS-CoV-2 in 2019, Ebola in 2013, HIV in 1980, Influenza in 1918). For example, SARS-CoV-2 has plagued higher than 317 000 000 people around the world from December 2019 to January 13, 2022. Some infectious diseases do not yet have not a proper vaccine, drug, therapeutic, and/or detection method, which makes rapid identification and definitive treatments the main challenges. Different device techniques have been used to detect infectious diseases. However, in recent years, magnetic materials have emerged as active sensors/biosensors for detecting viral, bacterial, and plasmids agents. In this review, the recent applications of magnetic materials in biosensors for infectious viruses detection have been discussed. Also, this work addresses the future trends and perspectives of magnetic biosensors.
Collapse
Affiliation(s)
| | - Mohammad Irani
- Department of Pharmaceutics, Faculty of Pharmacy, Alborz University of Medical Sciences, Karaj, Iran
| | - Mohammad Noorisepehr
- Environmental Health Engineering Research Center, Alborz University of Medical Sciences, Karaj, Iran
| | - Ali Maleki
- Catalysts and Organic Synthesis Research Laboratory, Department of Chemistry, Iran University of Science and Technology, Tehran 16846-13114, Iran
| |
Collapse
|
20
|
Trinh KTL, Do HDK, Lee NY. Recent Advances in Molecular and Immunological Diagnostic Platform for Virus Detection: A Review. BIOSENSORS 2023; 13:490. [PMID: 37185566 PMCID: PMC10137144 DOI: 10.3390/bios13040490] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/14/2023] [Accepted: 04/18/2023] [Indexed: 05/17/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused an ongoing coronavirus disease (COVID-19) outbreak and a rising demand for the development of accurate, timely, and cost-effective diagnostic tests for SARS-CoV-2 as well as other viral infections in general. Currently, traditional virus screening methods such as plate culturing and real-time PCR are considered the gold standard with accurate and sensitive results. However, these methods still require sophisticated equipment, trained personnel, and a long analysis time. Alternatively, with the integration of microfluidic and biosensor technologies, microfluidic-based biosensors offer the ability to perform sample preparation and simultaneous detection of many analyses in one platform. High sensitivity, accuracy, portability, low cost, high throughput, and real-time detection can be achieved using a single platform. This review presents recent advances in microfluidic-based biosensors from many works to demonstrate the advantages of merging the two technologies for sensing viruses. Different platforms for virus detection are classified into two main sections: immunoassays and molecular assays. Moreover, available commercial sensing tests are analyzed.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
21
|
Chang Y, Wang Y, Li W, Wei Z, Tang S, Chen R. Mechanisms, Techniques and Devices of Airborne Virus Detection: A Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:5471. [PMID: 37107752 PMCID: PMC10138381 DOI: 10.3390/ijerph20085471] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/13/2023] [Accepted: 04/03/2023] [Indexed: 05/11/2023]
Abstract
Airborne viruses, such as COVID-19, cause pandemics all over the world. Virus-containing particles produced by infected individuals are suspended in the air for extended periods, actually resulting in viral aerosols and the spread of infectious diseases. Aerosol collection and detection devices are essential for limiting the spread of airborne virus diseases. This review provides an overview of the primary mechanisms and enhancement techniques for collecting and detecting airborne viruses. Indoor virus detection strategies for scenarios with varying ventilations are also summarized based on the excellent performance of existing advanced comprehensive devices. This review provides guidance for the development of future aerosol detection devices and aids in the control of airborne transmission diseases, such as COVID-19, influenza and other airborne transmission viruses.
Collapse
Affiliation(s)
- Yuqing Chang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Yuqian Wang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Wen Li
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.L.); (Z.W.)
| | - Zewen Wei
- Department of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China; (W.L.); (Z.W.)
| | - Shichuan Tang
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| | - Rui Chen
- Beijing Key Laboratory of Occupational Safety and Health, Institute of Urban Safety and Environmental Science, Beijing Academy of Science and Technology, Beijing 100054, China; (Y.C.); (Y.W.); (S.T.)
| |
Collapse
|
22
|
Xu Q, Xiao F, Xu H. Fluorescent detection of emerging virus based on nanoparticles: From synthesis to application. Trends Analyt Chem 2023; 161:116999. [PMID: 36852170 PMCID: PMC9946731 DOI: 10.1016/j.trac.2023.116999] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Revised: 01/26/2023] [Accepted: 02/21/2023] [Indexed: 02/24/2023]
Abstract
The spread of COVID-19 has caused huge economic losses and irreversible social impact. Therefore, to successfully prevent the spread of the virus and solve public health problems, it is urgent to develop detection methods with high sensitivity and accuracy. However, existing detection methods are time-consuming, rely on instruments, and require skilled operators, making rapid detection challenging to implement. Biosensors based on fluorescent nanoparticles have attracted interest in the field of detection because of their advantages, such as high sensitivity, low detection limit, and simple result readout. In this review, we systematically describe the synthesis, intrinsic advantages, and applications of organic dye-doped fluorescent nanoparticles, metal nanoclusters, up-conversion particles, quantum dots, carbon dots, and others for virus detection. Furthermore, future research initiatives are highlighted, including green production of fluorescent nanoparticles with high quantum yield, speedy signal reading by integrating with intelligent information, and error reduction by coupling with numerous fluorescent nanoparticles.
Collapse
Affiliation(s)
- Qian Xu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Fangbin Xiao
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| | - Hengyi Xu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, PR China
| |
Collapse
|
23
|
He J, Zhu S, Zhou J, Jiang W, Yin L, Su L, Zhang X, Chen Q, Li X. Rapid detection of SARS-CoV-2: The gradual boom of lateral flow immunoassay. Front Bioeng Biotechnol 2023; 10:1090281. [PMID: 36704307 PMCID: PMC9871317 DOI: 10.3389/fbioe.2022.1090281] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Accepted: 12/13/2022] [Indexed: 01/12/2023] Open
Abstract
Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is still in an epidemic situation, which poses a serious threat to the safety of people and property. Rapid diagnosis and isolation of infected individuals are one of the important methods to control virus transmission. Existing lateral flow immunoassay techniques have the advantages of rapid, sensitive, and easy operation, and some new options have emerged with the continuous development of nanotechnology. Such as lateral flow immunoassay test strips based on colorimetric-fluorescent dual-mode and gold nanoparticles, Surface Enhanced Raman Scattering, etc., these technologies have played an important role in the rapid diagnosis of COVID-19. In this paper, we summarize the current research progress of lateral flow immunoassay in the field of Severe Acute Respiratory Syndrome Coronavirus 2 infection diagnosis, analyze the performance of Severe Acute Respiratory Syndrome Coronavirus 2 lateral flow immunoassay products, review the advantages and limitations of different detection methods and markers, and then explore the competitive CRISPR-based nucleic acid chromatography detection method. This method combines the advantages of gene editing and lateral flow immunoassay and can achieve rapid and highly sensitive lateral flow immunoassay detection of target nucleic acids, which is expected to be the most representative method for community and clinical point-of-care testing. We hope that researchers will be inspired by this review and strive to solve the problems in the design of highly sensitive targets, the selection of detection methods, and the enhancement of CRISPR technology, to truly achieve rapid, sensitive, convenient, and specific detection of novel coronaviruses, thus promoting the development of novel coronavirus diagnosis and contributing our modest contribution to the world's fight against epidemics.
Collapse
|
24
|
Liu Z, Wang C, Zheng S, Yang X, Han H, Dai Y, Xiao R. Simultaneously ultrasensitive and quantitative detection of influenza A virus, SARS-CoV-2, and respiratory syncytial virus via multichannel magnetic SERS-based lateral flow immunoassay. NANOMEDICINE : NANOTECHNOLOGY, BIOLOGY, AND MEDICINE 2023; 47:102624. [PMID: 36328340 PMCID: PMC9622431 DOI: 10.1016/j.nano.2022.102624] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 07/30/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]
Abstract
Respiratory viruses usually induced similar clinical symptoms at early infection. Herein, we presented a multichannel surface-enhanced Raman scattering-based lateral flow immunoassay (SERS-based LFA) using high-performance magnetic SERS tags for the simultaneous ultrasensitive detection of respiratory viruses, namely influenza A virus (H1N1), severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and respiratory syncytial virus (RSV) in biological samples. As-prepared magnetic SERS tags can directly enrich and capture target viruses without pretreatment of samples, avoiding the interference of impurities in the samples as well as improving the sensitivity. With the capture-detection method, the detection limits of the proposed assay reached 85 copies mL-1, 8 pg mL-1, and 8 pg mL-1 for H1N1, SARS-CoV-2 and RSV, respectively. Moreover, the detection properties of the proposed method for target viruses in throat swab samples were verified, suggesting its remarkable potential for the early and rapid differential diagnosis of respiratory viruses.
Collapse
|
25
|
Chen W, Chen H, Liu Y, Wei H, Wang Y, Rong Z, Liu X. An integrated fluorescent lateral flow assay for multiplex point-of-care detection of four respiratory viruses. Anal Biochem 2022; 659:114948. [PMID: 36216143 DOI: 10.1016/j.ab.2022.114948] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 09/24/2022] [Accepted: 10/03/2022] [Indexed: 12/14/2022]
Abstract
This work established a highly sensitive and specific quantum dot nanobeads-based lateral flow assay for multiplex detection of four respiratory virus markers at point of care. The respiratory virus antigens were detected by fluorescent lateral flow strips within 20 min. The limits of detection for SARS-CoV-2 antigen, IAV antigen, IBV antigen, and ADV antigen were 0.01 ng/mL, 0.05 ng/mL, 0.31 ng/mL, and 0.40 ng/mL, respectively, which were superior to that of conventional AuNPs-based colorimetric lateral flow assay. The coefficients of variation of the test strip were 6.09%, 2.24%, 7.92%, and 12.43% for these four antigens, which indicated that the proposed method had good repeatability. The specificity of the detection system was verified by different combinations of these four respiratory viruses and several other respiratory pathogens. These results indicated that this method could simultaneously detect SARS-CoV-2, IAV, IBV and ADV in a short assay time, showing the remarkable potential for the rapid and multiplex detection of respiratory viruses in resource-limited settings.
Collapse
Affiliation(s)
- Wenji Chen
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, 121012, PR China; Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Hong Chen
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Ye Liu
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Hongjuan Wei
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Yunxiang Wang
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China
| | - Zhen Rong
- Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, PR China.
| | - Xin Liu
- The First Affiliated Hospital of Jinzhou Medical University, Jinzhou, 121012, PR China; Jinzhou Medical University Huludao Central Hospital Teaching Base, Huludao, 125001, PR China.
| |
Collapse
|
26
|
Fang B, Xiong Q, Duan H, Xiong Y, Lai W. Tailored quantum dots for enhancing sensing performance of lateral flow immunoassay. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
27
|
Zhong X, Ma L, Yin G. Ion-Imprinted Chitosan-Based Localized Surface Plasmon Resonance Sensor for Ni 2+ Detection. SENSORS (BASEL, SWITZERLAND) 2022; 22:9005. [PMID: 36433601 PMCID: PMC9694492 DOI: 10.3390/s22229005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/15/2022] [Accepted: 11/16/2022] [Indexed: 06/16/2023]
Abstract
Heavy metals are important sources of environmental pollution and cause disease in organisms throughout the food chain. A localized surface plasmon resonance sensor was proposed and demonstrated to realize Ni2+ detection by using ion-imprinted chitosan. Au nanoparticles were coated on the multimode fiber to excite the local surface plasmon resonance, and Ni2+-imprinted chitosan was then functionalized by using the dip coating technique. Ethylene diamine tetra-acetic acid was used to release the Ni2+ ions and hence form countless voids. Ni2+ was refilled into the voids to increase the refractive index of the sensing material, thus realizing the measurement of Ni2+ by monitoring the wavelength shift in the localized surface plasmon resonant peak. The coating thickness of the Ni2+-chitosan gel was optimized to obtain greater sensitivity. Experimental results show that the proposed Ni2+ sensor has a sensitivity of 185 pm/μM, and the limit of detection is 0.512 μM. The comparison experiments indicated that the ion-imprinted chitosan has better selectivity than pure chitosan.
Collapse
Affiliation(s)
- Xiujuan Zhong
- College of Chemistry & Chemical Engineering, Chongqing University, Chongqing 400044, China
| | - Li Ma
- College of Chemistry & Chemical Engineering, Chongqing University, Chongqing 400044, China
| | - Guolu Yin
- Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China
| |
Collapse
|
28
|
Yang Y, Zhao R, Wang Y, Song D, Jiang B, Guo X, Liu W, Long F, Song H, Hao R. Rapid and universal detection of SARS-CoV-2 and influenza A virus using a reusable dual-channel optic fiber immunosensor. J Med Virol 2022; 94:5325-5335. [PMID: 35859097 PMCID: PMC9349508 DOI: 10.1002/jmv.28015] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 07/12/2022] [Accepted: 07/15/2022] [Indexed: 12/15/2022]
Abstract
Establishment of rapid on-site detection technology capable of concurrently detecting SARS-Cov-2 and influenza A virus is urgent to effectively control the epidemic from these two types of important viruses. Accordingly, we developed a reusable dual-channel optical fiber immunosensor (DOFIS), which utilized the evanescent wave-sensing properties and tandem detection mode of the mobile phase, effectively accelerating the detection process such that it can be completed within 10 min. It could detect the nucleoprotein of multiple influenza A viruses (H1N1, H3N2, and H7N9), as well as the spike proteins of the SARS-CoV-2 Omicron and Delta variants, and could respond to 20 TCID50 /ml SARS-CoV-2 pseudovirus and 100 TCID50 /ml influenza A (A/PR/8/H1N1), presenting lower limit of detection and wider linear range than enzyme-linked immunosorbent assay. The detection results on 26 clinical samples for SARS-CoV-2 demonstrated its specificity (100%) and sensitivity (94%), much higher than the sensitivity of commercial colloidal gold test strip (35%). Particularly, DOFIS might be reused more than 80 times, showing not only cost-saving but also potential in real-time monitoring of the pathogenic viruses. Therefore, this newly-developed DOFIS platform is low cost, simple to operate, and has broad spectrum detection capabilities for SARS-CoV-2 mutations and multiple influenza A strains. It may prove suitable for deployment as a rapid on-site screening and surveillance technique for infectious disease.
Collapse
Affiliation(s)
- Yi Yang
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Rongtao Zhao
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Yule Wang
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Dan Song
- School of Environment and Natural ResourcesRenmin University of ChinaBeijingChina
| | - Bo Jiang
- Department of Toxicology and Sanitary Chemistry, School of Public HealthCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Environmental ToxicologyCapital Medical UniversityBeijingChina
| | - Xudong Guo
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Wanying Liu
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Feng Long
- School of Environment and Natural ResourcesRenmin University of ChinaBeijingChina
| | - Hongbin Song
- Chinese PLA Center for Disease Control and PreventionBeijingChina
| | - Rongzhang Hao
- Chinese PLA Center for Disease Control and PreventionBeijingChina,Department of Toxicology and Sanitary Chemistry, School of Public HealthCapital Medical UniversityBeijingChina,Beijing Key Laboratory of Environmental ToxicologyCapital Medical UniversityBeijingChina
| |
Collapse
|
29
|
Guan T, Shen Y, Jiang Z, Wang J, Zhang S, Koidis A, Yao X, Yan Y, Lei H. Facile Fabrication of Highly Quantum Dot/AuNP-Loaded Tags for a Dual-Modal Colorimetric/Reversed Ratiometric Fluorescence Immunochromatographic Assay. Anal Chem 2022; 94:13463-13472. [PMID: 36131359 DOI: 10.1021/acs.analchem.2c02544] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Developing an easily-prepared, sensitive, and accurate point-of-need immunochromatographic assay (ICA) is significant in food safety screening, clinical diagnosis, and environmental monitoring. However, the current single-modal ICAs are limited in certain instinct drawbacks that restrict analytical performances. Herein, we introduce an ultrasensitive dual-modal colorimetric/reversed ratiometric fluorescence ICA based on facilely prepared immunoprobes with a high loading capacity of red quantum dots and AuNPs. By smartly integrating these red-colored/fluorescent signal probes with an immobilized green quantum dot antigen on the test lines, discrete "turn-on" visual inspection and reversed ratiometric quantification via a portable smartphone-based analyzer were accomplished. As an application, this method was employed to detect 11 phosphodiesterase-5 inhibitors in health foods with ultralow detection limits (0.0028-0.045 ng/mL), high repeatability (coefficient of variations of 0.3-1.91%), and reasonable accuracy (recoveries of 86.6-107%). The proposed method was further validated by the authorized liquid chromatography with tandem mass spectrometry method in actual sample detection. This new assay format can be extended to ultrasensitive flexible detection of other food contaminants, environmental pollutants, or tumor biomarkers within minutes, and it just requires simply prepared signal reporters, easy-to-operate procedures, and a low-cost miniaturized analyzer.
Collapse
Affiliation(s)
- Tian Guan
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou 510642, China.,Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China
| | - Yudong Shen
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China
| | - Zhuo Jiang
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China
| | - Jin Wang
- Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China
| | - Shiwei Zhang
- National Nutrition Food Testing Center, Shenzhen Academy of Metrology and Quality Inspection, Shenzhen 518131, China
| | - Anastasios Koidis
- Institute for Global Food Security, Queen's University Belfast, 19 Chlorine Gardens, Belfast BT9 5DJ, U.K
| | - Xiaojun Yao
- Dr. Neher's Biophysics Laboratory for Innovative Drug Discovery, State Key Laboratory of Quality Research in Chinese Medicine, Macau Institute for Applied Research in Medicine and Health, Macau University of Science and Technology, Macau 999078, China
| | - Yiyong Yan
- Bioeasy Technology, Inc., Shenzhen 518102, China
| | - Hongtao Lei
- Guangdong Laboratory for Lingnan Modern Agriculture, Guangzhou 510642, China.,Guangdong Provincial Key Laboratory of Food Quality and Safety/Nation-Local Joint Engineering Research Center for Machining and Safety of Livestock and Poultry Products, South China Agricultural University, Guangzhou 510642, China
| |
Collapse
|
30
|
Chatterjee S, Mukhopadhyay S. Recent advances of lateral flow immunoassay components as “point of need”. J Immunoassay Immunochem 2022; 43:579-604. [DOI: 10.1080/15321819.2022.2122063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Susraba Chatterjee
- Department of Laboratory Medicine, School of Tropical Medicine, 108, C.R.Avenue, Kolkata 700073, West Bengal
| | - Sumi Mukhopadhyay
- Department of Laboratory Medicine, School of Tropical Medicine, 108, C.R.Avenue, Kolkata 700073, West Bengal
| |
Collapse
|
31
|
Sena-Torralba A, Álvarez-Diduk R, Parolo C, Piper A, Merkoçi A. Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials. Chem Rev 2022; 122:14881-14910. [PMID: 36067039 PMCID: PMC9523712 DOI: 10.1021/acs.chemrev.1c01012] [Citation(s) in RCA: 112] [Impact Index Per Article: 37.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
![]()
Lateral flow assays (LFAs) are currently the most used
point-of-care
sensors for both diagnostic (e.g., pregnancy test, COVID-19 monitoring)
and environmental (e.g., pesticides and bacterial monitoring) applications.
Although the core of LFA technology was developed several decades
ago, in recent years the integration of novel nanomaterials as signal
transducers or receptor immobilization platforms has brought improved
analytical capabilities. In this Review, we present how nanomaterial-based
LFAs can address the inherent challenges of point-of-care (PoC) diagnostics
such as sensitivity enhancement, lowering of detection limits, multiplexing,
and quantification of analytes in complex samples. Specifically, we
highlight the strategies that can synergistically solve the limitations
of current LFAs and that have proven commercial feasibility. Finally,
we discuss the barriers toward commercialization and the next generation
of LFAs.
Collapse
Affiliation(s)
- Amadeo Sena-Torralba
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera s/n, 46022 Valencia, Spain
| | - Ruslan Álvarez-Diduk
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Claudio Parolo
- Barcelona Institute for Global Health (ISGlobal) Hospital Clínic-Universitat de Barcelona, Carrer del Rosselló 132, 08036 Barcelona, Spain
| | - Andrew Piper
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain
| | - Arben Merkoçi
- Nanobioelectronics & Biosensors Group, Institut Català de Nanociència I Nanotecnologia (ICN2), CSIC and The Barcelona Institute of Science and Technology (BIST), Campus UAB, Bellaterra, 08193 Barcelona, Spain.,Catalan Institution for Research and Advanced Studies (ICREA), Pg. Lluís Companys 23, 08010 Barcelona, Spain
| |
Collapse
|
32
|
Wu T, Li J, Zheng S, Yu Q, Qi K, Shao Y, Wang C, Tu J, Xiao R. Magnetic Nanotag-Based Colorimetric/SERS Dual-Readout Immunochromatography for Ultrasensitive Detection of Clenbuterol Hydrochloride and Ractopamine in Food Samples. BIOSENSORS 2022; 12:bios12090709. [PMID: 36140094 PMCID: PMC9496078 DOI: 10.3390/bios12090709] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 08/28/2022] [Accepted: 08/28/2022] [Indexed: 12/29/2022]
Abstract
Direct and sensitive detection of multiple illegal additives in complex food samples is still a challenge in on-site detection. In this study, an ultrasensitive immunochromatographic assay (ICA) using magnetic Fe3O4@Au nanotags as a capture/detection difunctional tool was developed for the direct detection of β2-adrenoceptor agonists in real samples. The Fe3O4@Au tag is composed of a large magnetic core (~160 nm), a rough Au nanoshell, dense surface-modified Raman molecules, and antibodies, which cannot only effectively enrich targets from complex solutions to reduce the matrix effects of food samples and improve detection sensitivity, but also provide strong colorimetric/surface-enhanced Raman scattering (SERS) dual signals for ICA testing. The dual readout signals of the proposed ICA can meet the detection requirements in different environments. Specifically, the colorimetric signal allows for rapid visual detection of the analyte, and the SERS signal is used for the sensitive and quantitative detection modes. The proposed dual-signal ICA can achieve the simultaneous determination of two illegal additives, namely, clenbuterol hydrochloride and ractopamine. The detection limits for the two targets via colorimetric and SERS signals were down to ng mL−1 and pg mL−1 levels, respectively. Moreover, the proposed assay has demonstrated high accuracy and stability in real food samples.
Collapse
Affiliation(s)
- Ting Wu
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
| | - Jiaxuan Li
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
| | - Shuai Zheng
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Qing Yu
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Kezong Qi
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Ying Shao
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
| | - Chongwen Wang
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
- College of Life Sciences, Anhui Agricultural University, Hefei 230036, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| | - Jian Tu
- Anhui Province Key Laboratory of Veterinary Pathobiology and Disease Control, College of Animal Science and Technology, Anhui Agricultural University, Hefei 230036, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| | - Rui Xiao
- Beijing Institute of Microbiology and Epidemiology, Beijing 100850, China
- Correspondence: (C.W.); (J.T.); (R.X.)
| |
Collapse
|
33
|
Zhang R, Liao T, Wang X, Zhai H, Yang D, Wang X, Wang H, Feng F. Second near-infrared fluorescent dye for lateral flow immunoassays rapid detection of influenza A/B virus. Anal Biochem 2022; 655:114847. [PMID: 35964731 DOI: 10.1016/j.ab.2022.114847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 07/29/2022] [Accepted: 08/02/2022] [Indexed: 11/19/2022]
Abstract
Sensitive and rapid diagnostic point of care testing (POCT) system is of great significance to prevent and control human virus infection. Here reported an immunochromatographic strip technology. The second near-infrared (NIR-II) fluorescent dye encapsulated into polystyrene (PS) nanoparticles, was integrated into a lateral flow assay platform to achieve excellent detection of influenza A/B. This surface-functionalized and mono-dispersed PS nanoparticles has been conjugated with influenza nucleoprotein monoclonal antibody as targets for influenza antigen-detection. This assay achieved the detection limit of 0.015 ng/mL for influenza A nucleoprotein and 4.3*10-5 HAU/mL (102.08 TCID50/mL) influenza A virus (influenza B: 0.037 ng/mL, 9.7*10-7 HAU/mL (100.43 TCID50/mL)). Compared with an Au-based lateral flow test strip, the strip's sensitivity is about 16-fold higher than it. Strip detection properties remain stable for 6 months under 4 °C to 30 °C storage. The assay's intra assay variation is 5.14% and the inter assay variation is 7.74%. Other potential endogenous and exogenous interfering substances (whole blood, nasal mucin, saliva, antipyretics, antihistamines and neuraminidase inhibitors) showed negative results, which verified the excellent specificity of this method. This assay was successfully applied to the POCT quantitative detection of influenza A/B virus, the sensitivity to influenza A and B viruses was 70% and 87.5% respectively, and the specificity was 100%. Therefore, these microspheres can be used as an effective material for rapid POCT detection in clinical specimens.
Collapse
Affiliation(s)
- Runxuan Zhang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Tao Liao
- WWHS Biotech, Inc, China, Shenzhen, 518000, China
| | - Xiao Wang
- Institute of Public Security, Northwest University of Political Science and Law, China, Xi'an, 710122, China
| | - Hong Zhai
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Di Yang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Xin Wang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| | - Haiyan Wang
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China.
| | - Feng Feng
- Department of Chemistry and Chemical Engineering, Shanxi Provincial Key Laboratory of Chemical Biosensing, China, Shanxi Datong University, Datong, 037009, China
| |
Collapse
|
34
|
Luo F, Geng X, Li Z, Dai G, Chu Z, He P, Zhang F, Wang Q. Biosensing bacterial 16S rDNA by microchip electrophoresis combined with a CRISPR system based on real-time crRNA/Cas12a formation. RSC Adv 2022; 12:22219-22225. [PMID: 36043114 PMCID: PMC9364175 DOI: 10.1039/d2ra03069a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 07/26/2022] [Indexed: 11/21/2022] Open
Abstract
The accurate, simple and sensitive detection of bacterial infections at the early stage is highly valuable in preventing the spread of disease. Recently, CRISPR-Cas12a enzyme-derived nucleic acid detection methods have emerged along with the discovery of the indiscriminate single-stranded DNA (ssDNA) cleavage activity of Cas12a. These nucleic acid detection methods are made effective and sensitive by combining them with isothermal amplification technologies. However, most of the proposed CRISPR-Cas12a strategies involve Cas-crRNA complexes in the preassembled mode, which result in inevitable nonspecific background signals. Besides, the signal ssDNA used in these strategies needs tedious pre-labeling of the signal molecules. Herein, a post-assembly CRISPR-Cas12a method has been proposed based on target-induced transcription amplification and real-time crRNA generation for bacterial 16S rDNA biosensing. This strategy is label-free through the combination of microchip electrophoresis (MCE) detection. In addition, this method eliminates the need for a protospacer adjacent motif (PAM) on the target sequences, and has the potential to be an effective and simple method for nucleic acid detection and infectious disease diagnosis.
Collapse
Affiliation(s)
- Feifei Luo
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Xing Geng
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Zhi Li
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Ge Dai
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Zhaohui Chu
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Pingang He
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Fan Zhang
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| | - Qingjiang Wang
- School of Chemistry and Molecular Engineering, East China Normal University 500 Dongchuan Road Shanghai 200241 P. R. China +86 21 54340015
| |
Collapse
|
35
|
Bruno JG. Applications in Which Aptamers Are Needed or Wanted in Diagnostics and Therapeutics. Pharmaceuticals (Basel) 2022; 15:693. [PMID: 35745612 PMCID: PMC9228505 DOI: 10.3390/ph15060693] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 05/25/2022] [Accepted: 05/30/2022] [Indexed: 01/27/2023] Open
Abstract
One strategy for bringing aptamers more into the mainstream of biomedical diagnostics and therapeutics is to exploit niche applications where aptamers are truly needed or wanted for their innate differences versus antibodies. This brief review article highlights some of those relatively rare applications in which aptamers are necessary or better suited to the user requirements than antibodies with explanations for why the aptamer is a necessary or superior choice. These situations include when no commercial antibody exists, when antibodies are excessively difficult to develop against a particular target because the target is highly toxic to host animals, when antibodies fail to discriminate closely related targets, when a smaller size is preferable to penetrate a tissue, when humanized monoclonal antibodies are too expensive and when the target is rapidly evolving or mutating. Examples of each are provided to illustrate these points.
Collapse
Affiliation(s)
- John G Bruno
- Nanohmics Inc., 6201 E. Oltorf Street, Suite 400, Austin, TX 78640, USA
| |
Collapse
|
36
|
Chai F, Wang D, Zhu L, Zheng W, Jiang X. Dual Gold Nanoparticle/Chemiluminescent Immunoassay for Sensitive Detection of Multiple Analytes. Anal Chem 2022; 94:6628-6634. [PMID: 35452227 DOI: 10.1021/acs.analchem.2c01177] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Multiple antibiotics and mycotoxins usually simultaneously exist in foods, which poses a serious threat to human health. How to detect them in one test with high sensitivity and fidelity is challenging. In this study, we develop a dual readout lateral flow immunodetection platform that can quantitatively detect five kinds of antibiotics and five kinds of mycotoxins within one sample. The platform is composed of a chip and a portable readout instrument where gold nanoparticle (AuNP)-based and chemiluminescence immunoassays could be performed to reach a maximum throughput of 220 analytes in one setting. For a rapid screen, qualitative analysis by detecting the color change of the deposited AuNPs on the chip could be realized. For quantitative results, chemiluminescence imaging and analysis can be completed within 15 min. Apart from the high throughput and high efficiency, this platform has a high detection sensitivity. For instance, the limit of detection (LOD) for thiamphenicol (a representative antibiotic) and fumonisins B1 (a representative mycotoxin) is 8 times and 40 times lower than those of the previously reported methods, respectively. Thus, this dual readout immunodetection platform is promising as a universal device for rapid and quantitative detection of multiple analytes with high throughput, high sensitivity, and high fidelity.
Collapse
Affiliation(s)
- Fengli Chai
- Department of Chemistry, School of Science, Tianjin University, Tianjin 300072, P. R. China.,Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, P. R. China.,Beijing Engineering Research Center for BioNanotechnology, CAS key Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for NanoScience and Technology, Beijing 100190, P. R. China
| | - Dou Wang
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Lina Zhu
- Department of Chemistry, School of Science, Tianjin University, Tianjin 300072, P. R. China
| | - Wenfu Zheng
- Beijing Engineering Research Center for BioNanotechnology, CAS key Laboratory for Biological Effects of Nanomaterials and Nanosafety, National Center for NanoScience and Technology, Beijing 100190, P. R. China
| | - Xingyu Jiang
- Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| |
Collapse
|
37
|
Wang Y, Chen H, Wei H, Rong Z, Wang S. Tetra-primer ARMS-PCR combined with dual-color fluorescent lateral flow assay for the discrimination of SARS-CoV-2 and its mutations with a handheld wireless reader. LAB ON A CHIP 2022; 22:1531-1541. [PMID: 35266944 DOI: 10.1039/d1lc01167g] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Several virulent variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have emerged along with the spread of this virus throughout the population. Some variants can exhibit increased transmissibility and reduced immune neutralization reactivity. These changes are deeply concerning issues that may hinder the ongoing effort of epidemic control measures, especially mass vaccination campaigns. The accurate discrimination of SARS-CoV-2 and its emerging variants is essential to contain the coronavirus disease 2019 pandemic. Herein, we report a low-cost, facile, and highly sensitive diagnostic platform that can simultaneously distinguish wild-type (WT) SARS-CoV-2 and its two mutations, namely, D614G and N501Y, within 2 h. WT or mutant (M) nucleic acid fragments at each allelic locus were selectively amplified by the tetra-primer amplification refractory mutation system (ARMS)-PCR assay. Allele-specific amplicons were simultaneously detected by two test lines on a quantum dot nanobead (QB)-based dual-color fluorescent test strip, which could be interpreted by the naked eye or by a home-made fluorescent strip readout device that was wirelessly connected to a smartphone for quantitative data analysis and result presentation. The WT and M viruses were indicated and were strictly discriminated by the presence of a green or red band on test line 1 for the D614G site and test line 2 for the N501Y site. The limits of detection (LODs) for the WT and M D614G were estimated as 78.91 and 33.53 copies per μL, respectively. This assay was also modified for the simultaneous detection of the N and ORF1ab genes of SARS-CoV-2 with LODs of 1.90 and 6.07 copies per μL, respectively. The proposed platform can provide a simple, accurate, and affordable diagnostic approach for the screening of SARS-CoV-2 and its variants of concern even in resource-limited settings.
Collapse
Affiliation(s)
- Yunxiang Wang
- Beijing Institute of Radiation Medicine, Beijing 100850, P. R. China.
- Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing 100850, P. R. China
| | - Hong Chen
- Beijing Institute of Radiation Medicine, Beijing 100850, P. R. China.
- Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing 100850, P. R. China
| | - Hongjuan Wei
- Beijing Institute of Radiation Medicine, Beijing 100850, P. R. China.
- Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing 100850, P. R. China
| | - Zhen Rong
- Beijing Institute of Radiation Medicine, Beijing 100850, P. R. China.
- Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing 100850, P. R. China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing 100850, P. R. China.
- Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases, Beijing 100850, P. R. China
| |
Collapse
|
38
|
Chen X, Li J, Zhong Y, Li X, Pan M, Qi H, Dong H, Zhang L. Highly Efficient and Stable CdZnSeS/ZnSeS Quantum Dots for Application in White Light-Emitting Diode. Front Chem 2022; 10:845206. [PMID: 35345537 PMCID: PMC8957214 DOI: 10.3389/fchem.2022.845206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 01/24/2022] [Indexed: 11/13/2022] Open
Abstract
Semiconductor quantum dots (QDs) are a promising luminescent phosphor for next-generation lightings and displays. In particular, QD-based white light-emitting diodes (WLEDs) are considered to be the candidate light sources with the most potential for application in displays. In this work, we synthesized quaternary/ternary core/shell alloyed CdZnSeS/ZnSeS QDs with high bright emission intensity. The QDs show good thermal stability by performing high temperature-dependent experiments that range from 295 to 433 K. Finally, the WLED based on the CdZnSeS/ZnSeS QDs exhibits a luminous efficiency (LE) of 28.14 lm/W, an external quantum efficiency (EQE) of 14.86%, and a warm bright sunlight close to the spectrum of daylight (Commission Internationale de l'éclairage (CIE) coordinates 0.305, 0.371). Moreover, the photoluminescence (PL) intensity, LE, EQE, and correlated color temperature (CCT) of as-prepared QD WLED remained relatively stable with only slight changes in the luminescence stability experiment.
Collapse
Affiliation(s)
- Xi Chen
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Jingzhou Li
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
- *Correspondence: Jingzhou Li, ; Mingzhong Pan, ; Hongxing Qi,
| | - Yichi Zhong
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
| | - Xin Li
- University of Chinese Academy of Sciences, Beijing, China
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
| | - Mingzhong Pan
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
- *Correspondence: Jingzhou Li, ; Mingzhong Pan, ; Hongxing Qi,
| | - Hongxing Qi
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- University of Chinese Academy of Sciences, Beijing, China
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
- *Correspondence: Jingzhou Li, ; Mingzhong Pan, ; Hongxing Qi,
| | - Hongxing Dong
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
- Shanghai Institute of Optics and Fine Mechanic, Chinese Academy of Sciences, Shanghai, China
| | - Long Zhang
- Hangzhou Institute for Advanced Study, University of Chinese Academy of Science, Hangzhou, China
- Shanghai Institute of Optics and Fine Mechanic, Chinese Academy of Sciences, Shanghai, China
| |
Collapse
|
39
|
Chen H, Wang Y, Wei H, Rong Z, Wang S. A rapid water bath PCR combined with lateral flow assay for the simultaneous detection of SARS-CoV-2 and influenza B virus. RSC Adv 2022; 12:3437-3444. [PMID: 35425347 PMCID: PMC8979286 DOI: 10.1039/d1ra07756b] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
The outbreak of the coronavirus disease 2019 caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in significant global health and economic threats to the human society. Thus, a rapid and accurate detection method for early testing and diagnosis should be established. In this study, a rapid water bath polymerase chain reaction (PCR) combined with lateral flow assay was developed to detect SARS-CoV-2 and influenza B virus simultaneously. A homemade automated transfer device equipped with reaction tube shuttled rapidly between two water baths at 98 °C and 53 °C to realize rapid PCR. After amplification, two-ended labeled PCR products were detected using the lateral flow strip with two test lines and streptavidin-conjugated quantum dot nanobeads. The fluorescence value was read using a handheld instrument. The established assay could complete reverse-transcription PCR amplification and lateral flow detection in 45 minutes. The detection limits were 8.44 copies per μL and 14.23 copies per μL for SARS-CoV-2 and influenza B virus, respectively. The coefficients of variation of the test strip were 10.10% for the SARS-CoV-2 and 4.94% for the influenza B virus, demonstrating the excellent repeatability of the experiment. These results indicated that the rapid PCR combined with lateral flow assay could detect SARS-CoV-2 and influenza B virus simultaneously at a short assay time and low cost, thereby showing the remarkable potential for the rapid and multiplex detection of respiratory viruses in resource-limited settings. Rapid and highly sensitive multiplex detection of SARS-CoV-2 and influenza B virus using water bath PCR-combined fluorescent lateral flow assay.![]()
Collapse
Affiliation(s)
- Hong Chen
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Yunxiang Wang
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Hongjuan Wei
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Zhen Rong
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine Beijing 100850 P. R. China .,Beijing Key Laboratory of New Molecular Diagnosis Technologies for Infectious Diseases Beijing 100850 P. R. China
| |
Collapse
|
40
|
Wang X, Li M, Duan T, Zou Y, Zhou X. A dual responsive fluorescent probe for selective detection of cysteine and bisulfite and its application in bioimaging. RSC Adv 2021; 12:874-877. [PMID: 35425127 PMCID: PMC8978911 DOI: 10.1039/d1ra08317a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 12/17/2021] [Indexed: 12/30/2022] Open
Abstract
A coumarin-based dual responsive fluorescent probe with a simple structure was developed for the detection of Cys and HSO3 -. Under simulated physiological conditions, Cou-F displayed an on-off fluorescence response to Cys at 521 nm and an off-on fluorescence response to HSO3 - at 500 nm. Furthermore, Cou-F had the advantages of high sensitivity, strong specificity and rapid response. The detection limits of Cou-F toward Cys and HSO3 - were 0.54 μM and 0.65 μM, respectively. Cou-F enabled high selective responses to Cys and HSO3 - over other biologically related species. The response times of Cou-F toward Cys and HSO3 - were 80 s and 100 s. The fluorescence imaging of Cys and HSO3 - was achieved in living RAW246.7 cells.
Collapse
Affiliation(s)
- Xiaofeng Wang
- Department of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital of Hainan Medical University Haikou 570102 China
| | - Mingshun Li
- School of Pharmaceutical Sciences, Southern Medical University Guangzhou 510515 China
| | - Tingting Duan
- Department of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital of Hainan Medical University Haikou 570102 China
| | - Yuxia Zou
- Department of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital of Hainan Medical University Haikou 570102 China
| | - Xuejun Zhou
- Department of Otolaryngology, Head and Neck Surgery, The First Affiliated Hospital of Hainan Medical University Haikou 570102 China
| |
Collapse
|
41
|
Ensuring food safety using fluorescent nanoparticles-based immunochromatographic test strips. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.10.025] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
42
|
Lateral flow assays (LFA) as an alternative medical diagnosis method for detection of virus species: The intertwine of nanotechnology with sensing strategies. Trends Analyt Chem 2021; 145:116460. [PMID: 34697511 PMCID: PMC8529554 DOI: 10.1016/j.trac.2021.116460] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Viruses are responsible for multiple infections in humans that impose huge health burdens on individuals and populations worldwide. Therefore, numerous diagnostic methods and strategies have been developed for prevention, management, and decreasing the burden of viral diseases, each having its advantages and limitations. Viral infections are commonly detected using serological and nucleic acid-based methods. However, these conventional and clinical approaches have some limitations that can be resolved by implementing other detector devices. Therefore, the search for sensitive, selective, portable, and costless approaches as efficient alternative clinical methods for point of care testing (POCT) analysis has gained much attention in recent years. POCT is one of the ultimate goals in virus detection, and thus, the tests need to be rapid, specific, sensitive, accessible, and user-friendly. In this review, after a brief overview of viruses and their characteristics, the conventional viral detection methods, the clinical approaches, and their advantages and shortcomings are firstly explained. Then, LFA systems working principles, benefits, classification are discussed. Furthermore, the studies regarding designing and employing LFAs in diagnosing different types of viruses, especially SARS-CoV-2 as a main concern worldwide and innovations in the LFAs' approaches and designs, are comprehensively discussed here. Furthermore, several strategies addressed in some studies for overcoming LFA limitations like low sensitivity are reviewed. Numerous techniques are adopted to increase sensitivity and perform quantitative detection. Employing several visualization methods, using different labeling reporters, integrating LFAs with other detection methods to benefit from both LFA and the integrated detection device advantages, and designing unique membranes to increase reagent reactivity, are some of the approaches that are highlighted.
Collapse
|
43
|
Wang C, Yang X, Zheng S, Cheng X, Xiao R, Li Q, Wang W, Liu X, Wang S. Development of an ultrasensitive fluorescent immunochromatographic assay based on multilayer quantum dot nanobead for simultaneous detection of SARS-CoV-2 antigen and influenza A virus. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 345:130372. [PMID: 34219970 PMCID: PMC8239248 DOI: 10.1016/j.snb.2021.130372] [Citation(s) in RCA: 55] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 06/15/2021] [Accepted: 06/26/2021] [Indexed: 05/02/2023]
Abstract
Rapid and accurate diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus (FluA) antigens in the early stages of virus infection is the key to control the epidemic spread. Here, we developed a two-channel fluorescent immunochromatographic assay (ICA) for ultrasensitive and simultaneous qualification of the two viruses in biological samples. A high-performance quantum dot nanobead (QB) was fabricated by adsorption of multilayers of dense quantum dots (QDs) onto the SiO2 surface and used as the highly luminescent label of the ICA system to ensure the high-sensitivity and stability of the assay. The combination of monodispersed SiO2 core (∼180 nm) and numerous carboxylated QDs formed a hierarchical shell, which ensured that the QBs possessed excellent stability, superior fluorescence signal, and convenient surface functionalization. The developed ICA biosensor achieved simultaneous detection of SARS-CoV-2 and FluA in one test within 15 min, with detection limits reaching 5 pg/mL for SARS-CoV-2 antigen and 50 pfu/mL for FluA H1N1. Moreover, our method showed high accuracy and specificity in throat swab samples with two orders of magnitude improvement in sensitivity compared with traditional AuNP-based ICA method. Hence, the proposed method is a promising and convenient tool for detection of respiratory viruses.
Collapse
Affiliation(s)
- Chongwen Wang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xingsheng Yang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shuai Zheng
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xiaodan Cheng
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Rui Xiao
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Qingjun Li
- School of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Wenqi Wang
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Xiaoxian Liu
- College of Life Sciences, Anhui Agricultural University, Hefei, 230036, PR China
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Shengqi Wang
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| |
Collapse
|
44
|
Li G, Ma W, Mo J, Cheng B, Shoda SI, Zhou D, Ye XS. Influenza Virus Precision Diagnosis and Continuous Purification Enabled by Neuraminidase-Resistant Glycopolymer-Coated Microbeads. ACS APPLIED MATERIALS & INTERFACES 2021; 13:46260-46269. [PMID: 34547894 DOI: 10.1021/acsami.1c11561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Rapid diagnosis and vaccine development are critical to prevent the threat posed by viruses. However, rapid tests, such as colloidal gold assays, yield false-negative results due to the low quantities of viruses; moreover, conventional virus purification, including ultracentrifugation and nanofiltration, is multistep and time-consuming, which limits laboratory research and commercial development of viral vaccines. A rapid virus enrichment and purification technique will improve clinical diagnosis sensitivity and simplify vaccine production. Hence, we developed the surface-glycosylated microbeads (glycobeads) featuring chemically synthetic glycoclusters and reversible linkers to selectively capture the influenza virus. The surface plasmon resonance (SPR) evaluation indicated broad spectrum affinity of S-linked glycosides to various influenza viruses. The magnetic glycobeads were integrated into clinical rapid diagnosis, leading to a 30-fold lower limit of detection. Additionally, the captured viruses can be released under physiological conditions, delivering purified viruses with >50% recovery and without decreasing their native infectivity. Notably, this glycobead platform will facilitate the sensitive detection and continuous one-step purification of the target virus that contributes to future vaccine production.
Collapse
Affiliation(s)
- Gefei Li
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| | - Wenxiao Ma
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| | - Juan Mo
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| | - Boyang Cheng
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| | - Shin-Ichiro Shoda
- Department of Biomolecular Engineering, Graduate School of Engineering, Tohoku University, 6-6-11, Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Demin Zhou
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| | - Xin-Shan Ye
- State Key Laboratory of Natural and Biomimetic Drugs, School of Pharmaceutical Sciences, Peking University, Xue Yuan Road No. 38, Beijing 100191, China
| |
Collapse
|
45
|
Wei D, Liu J, Wang Z, Zhou S, Wang S, Tong W, Peng J. Quantum Dot Nanobeads Based Fluorescence Immunoassay for the Quantitative Detection of Sulfamethazine in Chicken and Milk. SENSORS 2021; 21:s21196604. [PMID: 34640926 PMCID: PMC8512902 DOI: 10.3390/s21196604] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 09/24/2021] [Accepted: 09/28/2021] [Indexed: 12/15/2022]
Abstract
Sulfamethazine (SMZ) as a broad antibiotic is widely used in livestock and poultry. However, the abuse of SMZ in livestock feed can lead to SMZ residues in food and the resistance of bacteria to drugs. Thus, a method for the detection of SMZ in food is urgently needed. In this study, quantum dot (QD) nanobeads (QBs) were synthesized by encapsulating CdSe/ZnS QDs using a microemulsion technique. The prepared QBs as signal probes were applied in lateral flow immunoassay (LFIA) for the detection of SMZ in chicken and milk. Our proposed method had limits of detection of 0.1138–0.0955 ng/mL and corresponding linear ranges of 0.2–12.5, 0.1–15 ng/mL in chicken and milk samples, respectively. The recovery of LFIA for the detection of SMZ was 80.9–109.4% and 84–101.6% in chicken and milk samples, respectively. Overall, the developed QBs-LFIA had high reliability and excellent potential for rapid and sensitive screening of SMZ in food.
Collapse
Affiliation(s)
- Daixian Wei
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
| | - Jintao Liu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
| | - Zexiang Wang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
| | - Shu Zhou
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
- Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047, China
| | - Suhua Wang
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
| | - Weipeng Tong
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China; (D.W.); (J.L.); (Z.W.); (S.Z.); (S.W.); (W.T.)
- Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047, China
| | - Juan Peng
- School of Food Science and Technology, Nanchang University, Nanchang 330047, China
- Correspondence: ; Tel.: +86-18879145029
| |
Collapse
|
46
|
Lim JW, Ahn YR, Park G, Kim HO, Haam S. Application of Nanomaterials as an Advanced Strategy for the Diagnosis, Prevention, and Treatment of Viral Diseases. Pharmaceutics 2021; 13:1570. [PMID: 34683863 PMCID: PMC8540357 DOI: 10.3390/pharmaceutics13101570] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 09/19/2021] [Accepted: 09/23/2021] [Indexed: 12/23/2022] Open
Abstract
The coronavirus disease (COVID-19) pandemic poses serious global health concerns with the continued emergence of new variants. The periodic outbreak of novel emerging and re-emerging infectious pathogens has elevated concerns and challenges for the future. To develop mitigation strategies against infectious diseases, nano-based approaches are being increasingly applied in diagnostic systems, prophylactic vaccines, and therapeutics. This review presents the properties of various nanoplatforms and discusses their role in the development of sensors, vectors, delivery agents, intrinsic immunostimulants, and viral inhibitors. Advanced nanomedical applications for infectious diseases have been highlighted. Moreover, physicochemical properties that confer physiological advantages and contribute to the control and inhibition of infectious diseases have been discussed. Safety concerns limit the commercial production and clinical use of these technologies in humans; however, overcoming these limitations may enable the use of nanomaterials to resolve current infection control issues via application of nanomaterials as a platform for the diagnosis, prevention, and treatment of viral diseases.
Collapse
Affiliation(s)
- Jong-Woo Lim
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea; (J.-W.L.); (G.P.)
| | - Yu-Rim Ahn
- Division of Chemical Engineering and Bioengineering, College of Art, Culture and Engineering, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Korea;
- Biohealth-machinery Convergence Engineering, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Korea
| | - Geunseon Park
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea; (J.-W.L.); (G.P.)
| | - Hyun-Ouk Kim
- Division of Chemical Engineering and Bioengineering, College of Art, Culture and Engineering, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Korea;
- Biohealth-machinery Convergence Engineering, Kangwon National University, Chuncheon-si 24341, Gangwon-do, Korea
| | - Seungjoo Haam
- Department of Chemical and Biomolecular Engineering, Yonsei University, 50 Yonsei-ro, Seoul 03722, Korea; (J.-W.L.); (G.P.)
| |
Collapse
|
47
|
Wu K, Chugh VK, Krishna VD, Girolamo AD, Wang YA, Saha R, Liang S, Cheeran MCJ, Wang JP. One-Step, Wash-free, Nanoparticle Clustering-Based Magnetic Particle Spectroscopy Bioassay Method for Detection of SARS-CoV-2 Spike and Nucleocapsid Proteins in the Liquid Phase. ACS APPLIED MATERIALS & INTERFACES 2021; 13:44136-44146. [PMID: 34499464 PMCID: PMC8442556 DOI: 10.1021/acsami.1c14657] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Indexed: 05/04/2023]
Abstract
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high-accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround time that may worsen the disease surveillance and pandemic control. In sight of this situation, a rapid, one-step, easy-to-use, and high-accuracy diagnostic platform will be valuable for future epidemic control, especially for regions with scarce medical resources. Herein, we report a magnetic particle spectroscopy (MPS) platform for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) biomarkers: spike and nucleocapsid proteins. This technique monitors the dynamic magnetic responses of magnetic nanoparticles (MNPs) and uses their higher harmonics as a measure of the nanoparticles' binding states. By anchoring polyclonal antibodies (pAbs) onto MNP surfaces, these nanoparticles function as nanoprobes to specifically bind to target analytes (SARS-CoV-2 spike and nucleocapsid proteins in this work) and form nanoparticle clusters. This binding event causes detectable changes in higher harmonics and allows for quantitative and qualitative detection of target analytes in the liquid phase. We have achieved detection limits of 1.56 nM (equivalent to 125 fmole) and 12.5 nM (equivalent to 1 pmole) for detecting SARS-CoV-2 spike and nucleocapsid proteins, respectively. This MPS platform combined with the one-step, wash-free, nanoparticle clustering-based assay method is intrinsically versatile and allows for the detection of a variety of other disease biomarkers by simply changing the surface functional groups on MNPs.
Collapse
Affiliation(s)
- Kai Wu
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States
| | - Vinit Kumar Chugh
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States
| | - Venkatramana D. Krishna
- Department of Veterinary Population Medicine, University of Minnesota, St. Paul, MN 55108, United States
| | - Arturo di Girolamo
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States
| | | | - Renata Saha
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States
| | - Shuang Liang
- Department of Chemical Engineering and Material Science, University of Minnesota, Minneapolis, MN 55455, United States
| | - Maxim C-J Cheeran
- Department of Veterinary Population Medicine, University of Minnesota, St. Paul, MN 55108, United States
| | - Jian-Ping Wang
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN 55455, United States
| |
Collapse
|
48
|
Seifi T, Reza Kamali A. Antiviral performance of graphene-based materials with emphasis on COVID-19: A review. MEDICINE IN DRUG DISCOVERY 2021; 11:100099. [PMID: 34056572 PMCID: PMC8151376 DOI: 10.1016/j.medidd.2021.100099] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/06/2021] [Accepted: 05/19/2021] [Indexed: 02/06/2023] Open
Abstract
Coronavirus disease-2019 has been one of the most challenging global epidemics of modern times with a large number of casualties combined with economic hardships across the world. Considering that there is still no definitive cure for the recent viral crisis, this article provides a review of nanomaterials with antiviral activity, with an emphasis on graphene and its derivatives, including graphene oxide, reduced graphene oxide and graphene quantum dots. The possible interactions between surfaces of such nanostructured materials with coronaviruses are discussed. The antiviral mechanisms of graphene materials can be related to events such as the inactivation of virus and/or the host cell receptor, electrostatic trapping and physico-chemical destruction of viral species. These effects can be enhanced by functionalization and/or decoration of carbons with species that enhances graphene-virus interactions. The low-cost and large-scale preparation of graphene materials with enhanced antiviral performances is an interesting research direction to be explored.
Collapse
Affiliation(s)
- Tahereh Seifi
- Energy and Environmental Materials Research Centre (E2MC), School of Metallurgy, Northeastern University, Shenyang 110819, China
| | - Ali Reza Kamali
- Energy and Environmental Materials Research Centre (E2MC), School of Metallurgy, Northeastern University, Shenyang 110819, China
| |
Collapse
|
49
|
Wang C, Cheng X, Liu L, Zhang X, Yang X, Zheng S, Rong Z, Wang S. Ultrasensitive and Simultaneous Detection of Two Specific SARS-CoV-2 Antigens in Human Specimens Using Direct/Enrichment Dual-Mode Fluorescence Lateral Flow Immunoassay. ACS APPLIED MATERIALS & INTERFACES 2021; 13:40342-40353. [PMID: 34412466 PMCID: PMC8386037 DOI: 10.1021/acsami.1c11461] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/12/2021] [Indexed: 05/18/2023]
Abstract
Sensitive point-of-care methods for detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens in clinical specimens are urgently needed to achieve rapid screening of viral infection. We developed a magnetic quantum dot-based dual-mode lateral flow immunoassay (LFIA) biosensor for the high-sensitivity simultaneous detection of SARS-CoV-2 spike (S) and nucleocapsid protein (NP) antigens, which is beneficial for improving the detection accuracy and efficiency of SARS-CoV-2 infection in the point-of-care testing area. A high-performance magnetic quantum dot with a triple-QD shell (MagTQD) nanotag was first fabricated and integrated into the LFIA system to provide superior fluorescence signals, enrichment ability, and detectability for S/NP antigen testing. Two detection modes were provided by the proposed MagTQD-LFIA. The direct mode was used for rapid screening or urgent detection of suspected samples within 10 min, and the enrichment mode was used for the highly sensitive and quantitative analysis of SARS-CoV-2 antigens in biological samples without the interference of the "hook effect." The simultaneous detection of SARS-CoV-2 S/NP antigens was conducted in one LFIA strip, and the detection limits for two antigens under direct and enrichment modes were 1 and 0.5 pg/mL, respectively. The MagTQD-LFIA showed high accuracy, specificity, and stability in saliva and nasal swab samples and is an efficient tool with flexibility to meet the testing requirements for SARS-CoV-2 antigens in various situations.
Collapse
Affiliation(s)
- Chongwen Wang
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
- Beijing
Key Laboratory of New Molecular Diagnosis Technologies for Infectious
Diseases, Beijing 100850, P. R. China
| | - Xiaodan Cheng
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Liyan Liu
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Xiaochang Zhang
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Xingsheng Yang
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Shuai Zheng
- College
of Life Sciences, Anhui Agricultural University, Hefei 230036, P. R. China
| | - Zhen Rong
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
| | - Shengqi Wang
- Beijing
Institute of Radiation Medicine, Beijing 100850, P. R.
China
- Beijing
Key Laboratory of New Molecular Diagnosis Technologies for Infectious
Diseases, Beijing 100850, P. R. China
| |
Collapse
|
50
|
Wang XA, Shen W, Zhou B, Yu D, Tang X, Liu J, Huang X. The rationality of using core -shell nanoparticles with embedded internal standards for SERS quantitative analysis based glycerol-assisted 3D hotspots platform. RSC Adv 2021; 11:20326-20334. [PMID: 35479874 PMCID: PMC9033995 DOI: 10.1039/d1ra01957k] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 05/13/2021] [Indexed: 12/19/2022] Open
Abstract
Surface enhanced Raman spectroscopy (SERS) is a promising sensing technique that can provide unique chemical and structural fingerprint information, but gaining reliable SERS quantitative data with high sensitivity and stability still remains a challenge. Although using a molecule as an internal standard (IS) can improve the SERS quantitative capability, the reliability and SERS measuring conditions for signal fluctuations during calibration based on IS are yet to be explored when the embedded IS molecules and target objects are located in different environments. Herein, a 3D hotspot matrix SERS platform based on Au@4-MPy@AgNPs was constructed in water with the assistance of glycerol and the dynamic signal changes from the IS, i.e. 4-Mpy, and target molecules were monitored during the process of evaporation with high sensitivity and stability. In contrast to the traditional water-dispersed drying film system, the variation trends of IS and target molecules were consistent in the glycerol-assisted liquid film protection system. Therefore, it is reasonable to calibrate the signal fluctuation by utilizing the embedded IS based on the construction strategy of a glycerol-assisted 3D hotspot platform. This work demonstrates a rational, reliable and precise SERS quantitative technique for testing analyte concentrations in practical systems and has great application prospects in the field of analytical chemistry.
Collapse
Affiliation(s)
- Xiao-An Wang
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
- Institute of Physical Science and Information Technology, Anhui University Hefei 230601 China
| | - Wei Shen
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
| | - Binbin Zhou
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
- Department of Mechanical Engineering, City University of Hong Kong Kowloon Hong Kong China
| | - Daoyang Yu
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
| | - Xianghu Tang
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
| | - Jinhuai Liu
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
- Institute of Physical Science and Information Technology, Anhui University Hefei 230601 China
| | - Xingjiu Huang
- Environmental Materials and Pollution Control Laboratory, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences Hefei 230031 China +86-551-65591132 +86-551-65591142
- Institute of Physical Science and Information Technology, Anhui University Hefei 230601 China
| |
Collapse
|