1
|
Clark GG, Geisler D, Coey EJ, Pollitz LJ, Zaki FR, Huang C, Boppart SA, Nguyen TH. Influence of phosphate on bacterial release from activated carbon point-of-use filters and on biofilm characteristics. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 914:169932. [PMID: 38199359 PMCID: PMC11090127 DOI: 10.1016/j.scitotenv.2024.169932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 11/29/2023] [Accepted: 01/03/2024] [Indexed: 01/12/2024]
Abstract
Point-of-use (POU) filters certified to remove lead are often composed of activated carbon and have been shown to release high concentrations of bacteria, including opportunistic pathogens. In this study, we examine the impacts of the common corrosion inhibitor phosphate on biofilm characteristics and the relationship between biofilm structure and bacterial release from POU filters. This knowledge is essential for understanding how best to use the filters and where these filters fit in a system where other lead contamination prevention measures may be in place. We measured the bacterial release from activated carbon POU filters fed with groundwater - a common source of drinking water - with and without phosphate. We used optical coherence tomography (OCT) to quantitatively characterize biofilm growing on activated carbon filter material in which the biofilms were fed groundwater with and without phosphate. Phosphate filters released significantly less (57-87 %) bacteria than groundwater filters, and phosphate biofilms (median thickness: 82-331 μm) grew to be significantly thicker than groundwater biofilms (median thickness: 122-221 μm). The phosphate biofilm roughness ranged from 97 to 142 % of the groundwater biofilm roughness and was significantly greater in most weeks. Phosphate biofilms also had fewer pores per biofilm volume and shorter channels connecting those pores.
Collapse
Affiliation(s)
- Gemma G Clark
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States of America.
| | - Dietrich Geisler
- Department of Computer Science, Cornell University, United States of America
| | - Evan J Coey
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States of America
| | - Lance J Pollitz
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States of America
| | - Farzana R Zaki
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, United States of America
| | - Conghui Huang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States of America
| | - Stephen A Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, United States of America; Department of Bioengineering, Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, United States of America; Carle Illinois College of Medicine, United States of America
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, United States of America; Carle Illinois College of Medicine, United States of America; Institute of Genomic Biology, University of Illinois at Urbana-Champaign, United States of America
| |
Collapse
|
2
|
Hadiuzzaman M, Mirza N, Brown SP, Ladner DA, Salehi M. Lead (Pb) deposition onto new and biofilm-laden potable water pipes. CHEMOSPHERE 2023; 342:140135. [PMID: 37690561 DOI: 10.1016/j.chemosphere.2023.140135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 09/06/2023] [Accepted: 09/07/2023] [Indexed: 09/12/2023]
Abstract
Heavy metals' interactions with plumbing materials are complicated due to the differential formation of biofilms within pipes that can modulate, transform, and/or sequester heavy metals. This research aims to elucidate the mechanistic role of biofilm presence on Lead (Pb) accumulation onto crosslinked polyethylene (PEX-A), high-density polyethylene (HDPE), and copper potable water pipes. For this purpose, biofilms were grown on new pipes for three months. Five-day Pb exposure experiments were conducted to examine the kinetics of Pb accumulation onto the new and biofilm-laden pipes. Additionally, the influence of Pb initial concentration on the rate of its accumulation onto the pipes was examined. The results revealed greater biofilm biomass on the PEX-A pipes compared to the copper and HDPE pipes. More negative zeta potential was found for the biofilm-laden plastic pipes compared to the new plastic pipes. After five days of Pb exposure under stagnant conditions, the biofilm-laden PEX-A (980 μg m-2) and HDPE (1170 μg m-2) pipes accumulated more than three times the Pb surface loading compared to the new PEX-A (265 μg m-2) and HDPE pipes (329 μg m-2), respectively. However, under flow conditions, Pb accumulation on biofilm-laden plastic pipes was lower than on the new pipes. Moreover, with increasing the initial Pb concentration, greater rates of Pb surface accumulation were found for the biofilm-laden pipes compared to the new pipes under stagnant conditions. First-order kinetics model best described the Pb accumulation onto both new and biofilm-laden water pipes under both stagnant and flow conditions.
Collapse
Affiliation(s)
- Md Hadiuzzaman
- Department of Civil Engineering, The University of Memphis, Memphis, TN, USA
| | - Nahreen Mirza
- Department of Biological Sciences, The University of Memphis, Memphis, TN, USA
| | - Shawn P Brown
- Department of Biological Sciences, The University of Memphis, Memphis, TN, USA
| | - David A Ladner
- Department of Environmental Engineering and Earth Sciences, Clemson University, Anderson, SC, USA
| | - Maryam Salehi
- Department of Civil and Environmental Engineering, University of Missouri, Columbia, MO, USA.
| |
Collapse
|
3
|
Buder C, Meemken D, Fürstenberg R, Langforth S, Kirse A, Langkabel N. Drinking Pipes and Nipple Drinkers in Pig Abattoir Lairage Pens-A Source of Zoonotic Pathogens as a Hazard to Meat Safety. Microorganisms 2023; 11:2554. [PMID: 37894212 PMCID: PMC10609512 DOI: 10.3390/microorganisms11102554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 09/29/2023] [Accepted: 10/06/2023] [Indexed: 10/29/2023] Open
Abstract
The water distribution system in the lairage pens of abattoirs could act as a route of contamination for produced meat. In this study, biofilm formation and the occurrence of specific pathogens in drinking equipment was investigated in different lairage pens in a German commercial pig abattoir. Samples of the water and the drinkers in different locations were microbiologically cultivated and examined. After new drinking equipment had been installed for one month, three months and five years, biofilm formation was detectable, and retrograde growth from the nipple drinkers was seen up to the connection with the main water distribution system. In particular, Enterobacteriaceae and Pseudomonas spp. were found in all samplings of the nipple drinkers. Zoonotic pathogens, Salmonella, pathogenic Yersinia enterocolitica and methicillin-resistant Staphylococcus aureus, were also isolated from the nipple drinkers, while Listeria monocytogenes was not detected via microbial cultivation methods in any of the samples. Since the pigs take the contaminated nipple drinkers into their mouths to drink, or drink contaminated water containing the pathogens, transmission and even infection of the pigs in the lairage can be assumed. This could consequently lead to contamination or cross-contamination of the meat during slaughter and processing and to a public health risk.
Collapse
Affiliation(s)
- Celine Buder
- Working Group Meat Hygiene, Institute of Food Safety and Food Hygiene, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany; (C.B.); (R.F.); (S.L.); (N.L.)
- Veterinary Centre for Resistance Research, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany
| | - Diana Meemken
- Working Group Meat Hygiene, Institute of Food Safety and Food Hygiene, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany; (C.B.); (R.F.); (S.L.); (N.L.)
- Veterinary Centre for Resistance Research, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany
| | - Roland Fürstenberg
- Working Group Meat Hygiene, Institute of Food Safety and Food Hygiene, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany; (C.B.); (R.F.); (S.L.); (N.L.)
- Veterinary Centre for Resistance Research, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany
| | - Susann Langforth
- Working Group Meat Hygiene, Institute of Food Safety and Food Hygiene, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany; (C.B.); (R.F.); (S.L.); (N.L.)
- Veterinary Centre for Resistance Research, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany
| | - Alina Kirse
- Department of Biometry, Epidemiology and Information Processing, WHO Collaborating Centre for Research and Training for Health at the Human-Animal-Environment Interface, University of Veterinary Medicine Hannover, 30559 Hannover, Germany;
| | - Nina Langkabel
- Working Group Meat Hygiene, Institute of Food Safety and Food Hygiene, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany; (C.B.); (R.F.); (S.L.); (N.L.)
- Veterinary Centre for Resistance Research, School of Veterinary Medicine, Freie Universität Berlin, 14163 Berlin, Germany
| |
Collapse
|
4
|
Boxall J, Blokker M, Schaap P, Speight V, Husband S. Managing discolouration in drinking water distribution systems by integrating understanding of material behaviour. WATER RESEARCH 2023; 243:120416. [PMID: 37516082 DOI: 10.1016/j.watres.2023.120416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 06/30/2023] [Accepted: 07/24/2023] [Indexed: 07/31/2023]
Abstract
Discoloured drinking water, caused by elevated concentrations of organic and inorganic particles, is unacceptable. It occurs due to accumulation and subsequent mobilisation of material from within drinking water distribution infrastructure. Discolouration is currently partially explained by either the theories of cohesive layers or gravitational sedimentation. It is proposed and shown here how the processes behind these two theories both occur and how to integrate them to better explain observed behaviour and inform operational interventions to reduce discolouration. Deficiencies in understanding regarding the process and factors that influence material accumulation are highlighted. Future research addressing these deficiencies will enable determination of long term sustainable management strategies balancing capital investment and operational maintenance to safeguard distribution of high quality drinking water.
Collapse
Affiliation(s)
- Joby Boxall
- Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, UK.
| | - Mirjam Blokker
- KWR Water Research Institute, the Netherlands Delft University of Technology, the Netherlands
| | | | - Vanessa Speight
- Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, UK
| | - Stewart Husband
- Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, UK
| |
Collapse
|
5
|
Xia Y, Jayathilake PG, Li B, Zuliani P, Deehan D, Longyear J, Stoodley P, Chen J. Coupled CFD-DEM modelling to predict how EPS affects bacterial biofilm deformation, recovery and detachment under flow conditions. Biotechnol Bioeng 2022; 119:2551-2563. [PMID: 35610631 PMCID: PMC9544383 DOI: 10.1002/bit.28146] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 05/07/2022] [Accepted: 05/14/2022] [Indexed: 11/21/2022]
Abstract
The deformation and detachment of bacterial biofilm are related to the structural and mechanical properties of the biofilm itself. Extracellular polymeric substances (EPS) play an important role on keeping the mechanical stability of biofilms. The understanding of biofilm mechanics and detachment can help to reveal biofilm survival mechanisms under fluid shear and provide insight about what flows might be needed to remove biofilm in a cleaning cycle or for a ship to remove biofilms. However, how the EPS may affect biofilm mechanics and its deformation in flow conditions remains elusive. To address this, a coupled computational fluid dynamic– discrete element method (CFD‐DEM) model was developed. The mechanisms of biofilm detachment, such as erosion and sloughing have been revealed by imposing hydrodynamic fluid flow at different velocities and loading rates. The model, which also allows adjustment of the proportion of different functional groups of microorganisms in the biofilm, enables the study of the contribution of EPS toward biofilm resistance to fluid shear stress. Furthermore, the stress–strain curves during biofilm deformation have been captured by loading and unloading fluid shear stress to study the viscoelastic properties of the biofilm. Our predicted emergent viscoelastic properties of biofilms were consistent with relevant experimental measurements.
Collapse
Affiliation(s)
- Yuqing Xia
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, U.K
| | | | - Bowen Li
- School of Computing, Newcastle University, Newcastle upon Tyne, NE1 7RU, U.K
| | - Paolo Zuliani
- School of Computing, Newcastle University, Newcastle upon Tyne, NE1 7RU, U.K
| | - David Deehan
- The Medical School, Newcastle University, Newcastle upon Tyne, NE1 7RU, U.K.,Freeman Hospital, Newcastle upon Tyne, NE7 7DN, U.K
| | - Jennifer Longyear
- Marin, Protective, and Yacht Coatings, AkzoNobel, Gateshead, NE10 0JY, U.K
| | - Paul Stoodley
- Department of Microbial Infection and Immunity and the Department of Orthopaedics, The Ohio State University, Columbus, OH, 43210, USA.,National Centre for Advanced Tribology at Southampton (nCATS), National Biofilm Innovation Centre (NBIC), Mechanical Engineering, University of Southampton, Southampton, S017 1BJ, U.K
| | - Jinju Chen
- School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, U.K
| |
Collapse
|
6
|
Hess A, Baum C, Schiessl K, Besmer MD, Hammes F, Morgenroth E. Stagnation leads to short-term fluctuations in the effluent water quality of biofilters: A problem for greywater reuse? WATER RESEARCH X 2021; 13:100120. [PMID: 34647001 PMCID: PMC8495163 DOI: 10.1016/j.wroa.2021.100120] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 09/06/2021] [Accepted: 09/11/2021] [Indexed: 05/04/2023]
Abstract
A key characteristic of decentralized greywater treatment and reuse is high variability in both nutrient concentrations and flow. This variability in flow leads to stagnant water in the system and causes short-term fluctuations in the effluent water quality. Automated monitoring tools provide data to understand the mechanisms underlying the dynamics and to adapt control strategies accordingly. We investigated the fluctuations in a building-scale greywater treatment system comprising a membrane bioreactor followed by a biological activated carbon filter. Short-term dynamics in the effluent of the biological activated carbon filter were monitored with automated flow cytometry and turbidity, and the impact of these fluctuations on various hygiene-relevant parameters in the reuse water was evaluated. Continuous biofilm detachment into the stagnant water in the biological activated carbon filter led to temporarily increased turbidity and cell concentrations in the effluent after periods of stagnation. The fluctuations in cell concentrations were consistent with a model assuming higher detachment rates during flow than during times with stagnant water. For this system, total cell concentration and turbidity were strongly correlated. We also showed that the observed increase in cell concentration was not related to either an increase of organic carbon concentration or the concentration of two opportunistic pathogens, P. aeruginosa and L. pneumophila. Our findings demonstrate that turbidity measurements are sensitive to changes in the effluent water quality and can be used to monitor the fluctuations caused by intermittent flow. Intermittent flow did not lead to an increase in opportunistic pathogens, and this study provides no indications that stagnant water in biological activated carbon filters need be prevented.
Collapse
Affiliation(s)
- Angelika Hess
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
- ETH Zürich, Institute of Environmental Engineering, 8093 Zürich, Switzerland
| | - Chiara Baum
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
| | | | | | - Frederik Hammes
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
| | - Eberhard Morgenroth
- Eawag: Swiss Federal Institute of Aquatic Science and Technology, 8600 Dübendorf, Switzerland
- ETH Zürich, Institute of Environmental Engineering, 8093 Zürich, Switzerland
- Corresponding author.
| |
Collapse
|
7
|
Gloag ES, Wozniak DJ, Wolf KL, Masters JG, Daep CA, Stoodley P. Arginine Induced Streptococcus gordonii Biofilm Detachment Using a Novel Rotating-Disc Rheometry Method. Front Cell Infect Microbiol 2021; 11:784388. [PMID: 34805002 PMCID: PMC8602906 DOI: 10.3389/fcimb.2021.784388] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 10/21/2021] [Indexed: 11/13/2022] Open
Abstract
Oral diseases are one of the most common pathologies affecting human health. These diseases are typically associated with dental plaque-biofilms, through either build-up of the biofilm or dysbiosis of the microbial community. Arginine can disrupt dental plaque-biofilms, and maintain plaque homeostasis, making it an ideal therapeutic to combat the development of oral disease. Despite our understanding of the actions of arginine towards dental plaque-biofilms, it is still unclear how or if arginine effects the mechanical integrity of the dental plaque-biofilm. Here we adapted a rotating-disc rheometry assay, a method used to quantify marine biofilm fouling, to study how arginine treatment of Streptococcus gordonii biofilms influences biofilm detachment from surfaces. We demonstrate that the assay is highly sensitive at quantifying the presence of biofilm and the detachment or rearrangement of the biofilm structure as a function of shear stress. We demonstrate that arginine treatment leads to earlier detachment of the biofilm, indicating that arginine treatment weakens the biofilm, making it more susceptible to removal by shear stresses. Finally, we demonstrate that the biofilm disrupting affect is specific to arginine, and not a general property of amino acids, as S. gordonii biofilms treated with either glycine or lysine had mechanical properties similar to untreated biofilms. Our results add to the understanding that arginine targets biofilms by multifaceted mechanisms, both metabolic and physical, further promoting the potential of arginine as an active compound in dentifrices to maintain oral health.
Collapse
Affiliation(s)
- Erin S Gloag
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, United States
| | - Daniel J Wozniak
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, United States.,Department of Microbiology, The Ohio State University, Columbus, OH, United States
| | - Kevin L Wolf
- Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, OH, United States
| | - James G Masters
- Colgate-Palmolive Technology Center, Piscataway, NJ, United States
| | | | - Paul Stoodley
- Department of Microbial Infection and Immunity, The Ohio State University, Columbus, OH, United States.,Department of Orthopedics, The Ohio State University, Columbus, OH, United States.,National Biofilm Innovation Centre (NBIC) and National Centre for Advanced Tribology at Southampton (nCATS), University of Southampton, Southampton, United Kingdom
| |
Collapse
|
8
|
Pick FC, Fish KE, Husband S, Boxall JB. Non-invasive Biofouling Monitoring to Assess Drinking Water Distribution System Performance. Front Microbiol 2021; 12:730344. [PMID: 34777279 PMCID: PMC8581547 DOI: 10.3389/fmicb.2021.730344] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 09/28/2021] [Indexed: 11/13/2022] Open
Abstract
Biofilms are endemic in drinking water distribution systems (DWDS), forming on all water and infrastructure interfaces. They can pose risks to water quality and hence consumers. Our understanding of these biofilms is limited, in a large part due to difficulties in sampling them without unacceptable disruption. A novel, non-destructive and non-disruptive biofilm monitoring device (BMD), which includes use of flow cytometry analysis, was developed to assess biofouling rates. Laboratory based experiments established optimal configurations and verified reliable cell enumeration. Deployment at three operational field sites validated assessment of different biofouling rates. These differences in fouling rates were not obvious from bulk water sampling and analysis, but did have a strong correlation with long-term performance data of the associated networks. The device offers the potential to assess DWDS performance in a few months, compared to the number of years required to infer findings from historical customer contact data. Such information is vital to improve the management of our vast, complex and uncertain drinking water supply systems; for example rapidly quantifying the benefits of improvements in water treatment works or changes to maintenance of the network.
Collapse
Affiliation(s)
- Frances C Pick
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| | - Katherine E Fish
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| | - Stewart Husband
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| | - Joby B Boxall
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
9
|
de Vries HJ, Kleibusch E, Hermes GDA, van den Brink P, Plugge CM. Biofouling control: the impact of biofilm dispersal and membrane flushing. WATER RESEARCH 2021; 198:117163. [PMID: 33951583 DOI: 10.1016/j.watres.2021.117163] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 04/12/2021] [Accepted: 04/13/2021] [Indexed: 05/26/2023]
Abstract
Pure culture studies have shown that biofilm dispersal can be triggered if the nutrient supply is discontinued by stopping the flow. Stimulating biofilm dispersal in this manner would provide a sustainable manner to control unwanted biofilm growth in industrial settings, for instance on synthetic membranes used to purify water. The response of multispecies biofilms to nutrient limitation has not been thoroughly studied. To assess biomass dispersal during nutrient limitation it is common practise to flush the biofilm after a stop-period. Hence, flow-stop-induced biomass removal could occur as a response to nutrient limitation followed by mechanical removal due to biofilm flushing (e.g. biofilm detachment). Here, we investigated the feasibility to reduce membrane biofouling by stopping the flow and flushing the membrane. Using a membrane fouling simulator, biomass removal from synthetic membranes after different stop-periods was determined, as well as biomass removal at different cross flow velocities. Biomass removal from membrane surfaces depended on the nutrient limiting period and on the flow velocity during the biofilm flush. When flushed at a low flow velocity (0.1 m.s-1), the duration of the stop-period had a large effect on the biomass removal rate, but when the flow velocity was increased to 0.2 m.s-1, the length of the stop period became less considerable. The flow velocity during membrane flushing has an effect on the bacterial community that colonized the membranes afterwards. Repetition of the stop-period and biofilm flushing after three repetitive biofouling cycles led to a stable bacterial community. The increase in bacterial community stability coincided with a decrease in cleaning effectivity to restore membrane performance. This shows that membrane cleaning comes at the costs of a more stable bacterial community that is increasingly difficult to remove.
Collapse
Affiliation(s)
- Hendrik J de Vries
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE Wageningen, The Netherlands; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands
| | - Eva Kleibusch
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands
| | - Gerben D A Hermes
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE Wageningen, The Netherlands
| | - Paula van den Brink
- Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands
| | - Caroline M Plugge
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE Wageningen, The Netherlands; Wetsus, European Centre of Excellence for Sustainable Water Technology, Oostergoweg 9, 8911 MA Leeuwarden, The Netherlands.
| |
Collapse
|
10
|
The Effects of Chemical and Mechanical Stresses on Bacillus cereus and Pseudomonas fluorescens Single- and Dual-Species Biofilm Removal. Microorganisms 2021; 9:microorganisms9061174. [PMID: 34072497 PMCID: PMC8228086 DOI: 10.3390/microorganisms9061174] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 05/22/2021] [Accepted: 05/26/2021] [Indexed: 01/08/2023] Open
Abstract
Biofilm control is mainly based on chemical disinfection, without a clear understanding of the role of the biocides and process conditions on biofilm removal. This study aims to understand the effects of a biocide (benzyldimethyldodecyl ammonium chloride-BDMDAC) and mechanical treatment (an increase of shear stress -τw) on single- and dual-species biofilms formed by Bacillus cereus and Pseudomonas fluorescens on high-density polyethene (HDPE). BDMDAC effects were initially assessed on bacterial physicochemical properties and initial adhesion ability. Then, mature biofilms were formed on a rotating cylinder reactor (RCR) for 7 days to assess the effects of chemical and mechanical treatments, and the combination of both on biofilm removal. The results demonstrated that the initial adhesion does not predict the formation of mature biofilms. It was observed that the dual-species biofilms were the most susceptible to BDMDAC exposure. The exposure to increasing τw emphasised the mechanical stability of biofilms, as lower values of τw (1.66 Pa) caused high biofilm erosion and higher τw values (17.7 Pa) seem to compress the remaining biofilm. In general, the combination of BDMDAC and the mechanical treatment was synergic in increasing biofilm removal. However, these were insufficient to cause total biofilm removal (100%; an average standard deviation of 11% for the method accuracy should be considered) from HDPE.
Collapse
|
11
|
Abstract
Bio-contamination of water through biofouling, which involves the natural colonization of submerged surfaces by waterborne organisms, is a global socio-economic concern, allied to premature materials bio-corrosion and high human health risks. Most effective strategies release toxic and persistent disinfectant compounds into the aquatic medium, causing environmental problems and leading to more stringent legislation regarding their use. To minimize these side effects, a newly non-biocide-release coating strategy suitable for several polymeric matrices, namely polydimethylsiloxane and polyurethane (PU)-based coatings, was used to generate antimicrobial ceramic filters for water bio-decontamination. The best results, in terms of antimicrobial activity and biocide release, showed an expressed delay and a decrease of up to 66% in the population of methicillin-resistant Staphylococcus aureus bacteria on ceramic filters coated with polyurethane (PU)-based coatings containing grafted Econea biocide, and no evidence of biocide release after being submerged for 45 days in water. Biocidal PU-based surfaces were also less prone to Enterococcus faecalis biofilm formation under flow conditions with an average reduction of 60% after 48 h compared to a pristine PU-based surface. Biocidal coated filters show to be a potential eco-friendly alternative for minimizing the environmental risks associated with biofouling formation in water-based industrial systems.
Collapse
|
12
|
Shi Y, Babatunde A, Bockelmann-Evans B, Li Q, Zhang L. On-going nitrification in chloraminated drinking water distribution system (DWDS) is conditioned by hydraulics and disinfection strategies. J Environ Sci (China) 2020; 96:151-162. [PMID: 32819689 DOI: 10.1016/j.jes.2020.04.028] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Revised: 03/30/2020] [Accepted: 04/15/2020] [Indexed: 06/11/2023]
Abstract
Within the drinking water distribution system (DWDS) using chloramine as disinfectant, nitrification caused by nitrifying bacteria is increasingly becoming a concern as it poses a great challenge for maintaining water quality. To investigate efficient control strategies, operational conditions including hydraulic regimes and disinfectant scenarios were controlled within a flow cell experimental facility. Two test phases were conducted to investigate the effects on the extent of nitrification of three flow rates (Q = 2, 6, and 10 L/min) and four disinfection scenarios (total Cl2=1 mg/L, Cl2/NH3-N=3:1; total Cl2=1 mg/L, Cl2/NH3-N=5:1; total Cl2=5 mg/L, Cl2/NH3-N=3:1; and total Cl2=5 mg/L, Cl2/NH3-N=5:1). Physico-chemical parameters and nitrification indicators were monitored during the tests. The characteristics of biofilm extracellular polymetric substance (EPS) were evaluated after the experiment. The main results from the study indicate that nitrification is affected by hydraulic conditions and the process tends to be severe when the fluid flow transforms from laminar to turbulent (2300<Re<4000). Increasing disinfectant concentration and optimizing Cl2/NH3-N mass ratio were found to inhibit nitrification to some extend when the system was running at turbulent condition (Q = 10 L/min, Re = 5535). EPS extracted from biofilm that was established at the flow rate of 6 L/min had greater carbohydrate/protein ratio. Furthermore, several nitrification indicators were evaluated for their prediction efficiency and the results suggest that the change of nitrite, together with total organic carbon (TOC) and turbidity can indicate nitrification potential efficiently.
Collapse
Affiliation(s)
- Yi Shi
- National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, China; Discipline of Civil Engineering, Cardiff University School of Engineering, The Parade, Cardiff, CF24 3AA, UK.
| | - Akintunde Babatunde
- Discipline of Civil Engineering, Cardiff University School of Engineering, The Parade, Cardiff, CF24 3AA, UK; School of Civil Engineering, University of Leeds, Leeds, LS2, 9JT, UK
| | - Bettina Bockelmann-Evans
- Discipline of Civil Engineering, Cardiff University School of Engineering, The Parade, Cardiff, CF24 3AA, UK
| | - Qijie Li
- Discipline of Civil Engineering, Cardiff University School of Engineering, The Parade, Cardiff, CF24 3AA, UK
| | - Liang Zhang
- National Engineering Laboratory for Cereal Fermentation Technology, Jiangnan University, Wuxi 214122, China
| |
Collapse
|
13
|
Douterelo I, Dutilh BE, Arkhipova K, Calero C, Husband S. Microbial diversity, ecological networks and functional traits associated to materials used in drinking water distribution systems. WATER RESEARCH 2020; 173:115586. [PMID: 32065938 DOI: 10.1016/j.watres.2020.115586] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2019] [Revised: 01/22/2020] [Accepted: 02/02/2020] [Indexed: 06/10/2023]
Abstract
Drinking water distribution systems host complex microbial communities as biofilms that interact continuously with delivered water. Understanding the diversity, behavioural and functional characteristics will be a requisite for developing future monitoring strategies and protection against water-borne health risks. To improve understanding, this study investigates mobilisation and accumulation behaviour, microbial community structure and functional variations of biofilms developing on different pipe materials from within an operational network. Samples were collected from four pipes during a repeated flushing operation three months after an initial visit that used hydraulic forces to mobilise regenerating biofilms yet without impacting the upstream network. To minimise confounding factors, test sections were chosen with comparable daily hydraulic regimes, physical dimensions, and all connected straight of a common trunk main and within close proximity, hence similar water chemistry, pressure and age. Taxonomical results showed differences in colonising communities between pipe materials, with several genera, including the bacteria Pseudomonas and the fungi Cladosporium, present in every sample. Diverse bacterial communities dominated compared to more homogeneous fungal, or mycobiome, community distribution. The analysis of bacterial/fungal networks based on relative abundance of operational taxonomic units (OTUs) indicated microbial communities from cast iron pipes were more stable than communities from the non-ferrous pipe materials. Novel analysis of functional traits between all samples were found to be mainly associated to mobile genetic elements that play roles in determining links between cells, including phages, prophages, transposable elements, and plasmids. The use of functional traits can be considered for development in future surveillance methods, capable of delivering network condition information beyond that of limited conventional faecal indicator tests, that will help protect water quality and public health.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK.
| | - B E Dutilh
- Theoretical Biology and Bioinformatics, Science for Life, Utrecht University, Hugo R. Kruytgebouw, Padualaan 8, 3584, CH, Utrecht, the Netherlands; Centre for Molecular and Biomolecular Informatics, Radboud University Medical Centre, Geert Grooteplein Zuid 26-28, 6525, GA, Nijmegen, the Netherlands
| | - K Arkhipova
- Theoretical Biology and Bioinformatics, Science for Life, Utrecht University, Hugo R. Kruytgebouw, Padualaan 8, 3584, CH, Utrecht, the Netherlands
| | - C Calero
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK
| | - S Husband
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield, S1 3JD, UK
| |
Collapse
|
14
|
Hou P, Wang T, Zhou B, Song P, Zeng W, Muhammad T, Li Y. Variations in the microbial community of biofilms under different near-wall hydraulic shear stresses in agricultural irrigation systems. BIOFOULING 2020; 36:44-55. [PMID: 31985267 DOI: 10.1080/08927014.2020.1714600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2018] [Revised: 01/03/2020] [Accepted: 01/05/2020] [Indexed: 06/10/2023]
Abstract
The hydraulic characteristics along agricultural irrigation pipelines directly affect the local near-wall hydraulic shear stress and biofilm accumulation. However, the variations in the microbial community during the process remain unknown. Based on the Couette-Taylor reactor, a device was developed to accurately control the hydraulic shear stress. The results indicated that the near-wall hydraulic shear stresses showed quadratic correlations with microbial contents (represented by phospholipid fatty acids r > 0.77, p < 0.05), and the maximum values were obtained under the shear stresses of 0.20-0.35 Pa. For two types of treated wastewater, the mutual operational taxonomic units among different shear stress treatments showed good consistency (>185). Their corresponding response in the microbial community was represented by the quantitative correlations between the near-wall hydraulic shear stresses and the polymorphism indices (r > 0.82, p < 0.05). Among the microorganisms, Firmicutes at the phylum level were significantly affected by the shear stress and significantly influenced the biofilm accumulation process.
Collapse
Affiliation(s)
- Peng Hou
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
| | - Tianzhi Wang
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
| | - Bo Zhou
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
- Key Laboratory of Technologies and Models for Cyclic Utilization from Agricultural Resources, Ministry of Agriculture and Rural Affairs, Beijing, P.R. China
| | - Peng Song
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
| | - Wenzhi Zeng
- State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan, P.R. China
| | - Tahir Muhammad
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
| | - Yunkai Li
- College of Water Resources and Civil Engineering, China Agricultural University, Beijing, P.R. China
| |
Collapse
|
15
|
Gomes IB, Querido MM, Teixeira JP, Pereira CC, Simões LC, Simões M. Prolonged exposure of Stenotrophomonas maltophilia biofilms to trace levels of clofibric acid alters antimicrobial tolerance and virulence. CHEMOSPHERE 2019; 235:327-335. [PMID: 31265978 DOI: 10.1016/j.chemosphere.2019.06.184] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Revised: 06/13/2019] [Accepted: 06/24/2019] [Indexed: 06/09/2023]
Abstract
The presence of pharmaceuticals in water sources, including in drinking water (DW), is increasingly being recognized as an emerging and global concern for the environment and public health. Based on the principles of the "One Health" initiative, the present work aims to understand the effects of clofibric acid (CA), a lipid regulator, on the behavior of a selected bacterium isolated from drinking water (DW). Biofilms of the opportunistic pathogen Stenotrophomonas maltophilia were exposed to CA for 12 weeks at 170 and 17000 ng/L. The effects of CA were evaluated on planktonic S. maltophilia susceptibility to chlorine and antibiotics (amoxicillin, ciprofloxacin, erythromycin, kanamycin, levofloxacin, oxacillin, spectinomycin, tetracycline and trimethoprim-sulfamethoxazole), biofilm formation, motility, siderophores production and on the adhesion and internalization of the human colon adenocarcinoma cell line (HT-29). It was found that CA did not affect planktonic S. maltophilia tolerance to chlorine exposure. Additionally, no effects were observed on biofilm formation, motility and siderophores production. However, biofilms formed after CA exposure were more tolerant to chlorine disinfection and lower CFU reductions were obtained. Of additional concern was the effect of CA exposure on S. maltophilia increased tolerance to erythromycin. CA exposure also slightly reduced S. maltophilia ability to invade HT-29 cells. In conclusion, this work reinforces the importance of studying the effects of non-antibiotic contaminants on the behavior of environmental microorganisms, particularly their role as drivers affecting resistance evolution and selection.
Collapse
Affiliation(s)
- I B Gomes
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465, Porto, Portugal
| | - M M Querido
- Department of Environmental Health, Portuguese National Institute of Health DR. Ricardo Jorge, Rua Alexandre Herculano, 321, 4000-055, Porto, Portugal; EPIUnit - Institute of Public Health, University of Porto, Rua das Taipas, 135, 4050-600, Porto, Portugal
| | - J P Teixeira
- Department of Environmental Health, Portuguese National Institute of Health DR. Ricardo Jorge, Rua Alexandre Herculano, 321, 4000-055, Porto, Portugal; EPIUnit - Institute of Public Health, University of Porto, Rua das Taipas, 135, 4050-600, Porto, Portugal
| | - C C Pereira
- Department of Environmental Health, Portuguese National Institute of Health DR. Ricardo Jorge, Rua Alexandre Herculano, 321, 4000-055, Porto, Portugal; EPIUnit - Institute of Public Health, University of Porto, Rua das Taipas, 135, 4050-600, Porto, Portugal
| | - L C Simões
- CEB-Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057, Braga, Portugal
| | - M Simões
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465, Porto, Portugal.
| |
Collapse
|
16
|
Zhou X, Zhang K, Zhang T, Yang Y, Ye M, Pan R. Formation of odorant haloanisoles and variation of microorganisms during microbial O-methylation in annular reactors equipped with different coupon materials. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 679:1-11. [PMID: 31078770 DOI: 10.1016/j.scitotenv.2019.04.329] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 04/03/2019] [Accepted: 04/22/2019] [Indexed: 06/09/2023]
Abstract
Taste and odor (T & O) issues in drinking water have become serious problems which cannot be ignored by customers. Several studies have confirmed that microbes in water can biotransform halophenols (HPs) to haloanisoles (HAs) with earthy and musty flavors via microbial O-methylation. In this paper, the formation of 2-chloroanisole (2-CA), 2,4-dichloroanisole (2,4-DCA), 2,4,6-trichloroanisole (2,4,6-TCA), 2,3,6-trichloroanisole (2,3,6-TCA) and 2,4,6-tribromoanisole (2,4,6-TBA), and the microbial variation during the microbial O-methylation were investigated in annular reactors (ARs) with three coupon materials. For precursors, 42.5% of 2-CP and 68.9% of 2,4-DCP decayed during the reaction. Among the five HAs, the formation rate constant followed an order of 2,4,6-TCA > 2-CA > 2,4,6-TBA > 2,4-DCA ~ 2,3,6-TCA, while [HA]max followed a totally opposite one. The simulated flow velocity had no significant effect (p > 0.05) on HA formation. Ductile iron (DI) AR could produce more HAs than stainless steel (SS) and polyvinyl chloride (PVC) ARs. The final HA molar concentration followed an order of 2,3,6-TCA > 2,4-DCA > 2,4,6-TBA ~ 2,4,6-TCA > 2-CA, which might be explained by multiple factors including HP's dissociation degree, halogen atom's steric hindrance and specificity of HP O-methyltransferases. During the reaction, the microbial biomass dramatically increased 6.8-9.0 times in bulk water but dropped significantly on coupon biofilms. The effect of HPs significantly changed the bacterial communities on coupon in terms of composition and diversity, and declined the relative abundance of HA-producing bacteria, while fungi and their HA-producing genus showed better resistance ability towards HPs. By using Pearson correlation analysis, a significant correlation (p = 0.0003) was found between [HA]max and initial coupon biofilm biomass. Finally, a linear relationship was established between initial total biomass and HA formation potential.
Collapse
Affiliation(s)
- Xinyan Zhou
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China
| | - Kejia Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China.
| | - Tuqiao Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China
| | - Yulong Yang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China
| | - Miaomiao Ye
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China
| | - Renjie Pan
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, Zhejiang, China
| |
Collapse
|
17
|
Abada E, Al-Fifi Z, Al-Rajab AJ, Mahdhi M, Sharma M. Molecular identification of biological contaminants in different drinking water resources of the Jazan region, Saudi Arabia. JOURNAL OF WATER AND HEALTH 2019; 17:622-632. [PMID: 31313999 DOI: 10.2166/wh.2019.019] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Drinking water quality plays a remarkable role in human infections and diseases. This study used polymerase chain reaction (PCR) techniques to detect bacterial pathogens. In addition, a physicochemical analysis was performed on drinking water samples from several sources. A total of 123 drinking water samples were collected from different areas in the Jazan region in Saudi Arabia: ground water (40 samples), bottled water (15 samples), tap water (52 samples), and water purification shops (16 samples). To isolate the bacterial pathogens, the water samples were spread on Nutrient and MacConkey agar media, and the grown pathogens were then identified by the 16S ribosomal RNA technique. In 87 (70.7%) of the 123 drinking water samples, there was no pathogen growth on the two-culture medium. However, 36 (29.3%) of the samples were found to be contaminated with bacteria. The physicochemical analysis indicated that the water samples were within the Saudi drinking water standards. The bacteria were resistant to Cefotaxime, Cefotaxime/Clavulanic acid, Erythromycin, Penicillin G, Rifampin and Sulfamethoxazole-Trimethoprim, respectively. The findings suggest that in Jazan, bottled water is a safer source of potable water than tap water. The contamination in the water may be occurring at the reservoirs rather than the water sources.
Collapse
Affiliation(s)
- Emad Abada
- Biology Department, Faculty of Science, Jazan University, Jazan, Saudi Arabia E-mail: ; Botany and Microbiology Department, Faculty of Science, Helwan University, Cairo, Egypt
| | - Zarraq Al-Fifi
- Biology Department, Faculty of Science, Jazan University, Jazan, Saudi Arabia E-mail:
| | - Abdul Jabbar Al-Rajab
- Centre for Environmental Research and Studies, Jazan University, Jazan, Saudi Arabia; Etcetera Publications, Chesterville, Ontario, Canada
| | - Mosbah Mahdhi
- Centre for Environmental Research and Studies, Jazan University, Jazan, Saudi Arabia
| | - Mukul Sharma
- Centre for Environmental Research and Studies, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
18
|
Islam MA, Ehiraj B, Cheng CK, Dubey BN, Khan MMR. Biofilm re-vitalization using hydrodynamic shear stress for stable power generation in microbial fuel cell. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.05.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
19
|
Mathieu L, Keraval A, Declercq NF, Block JC. Assessment of a low-frequency ultrasound device on prevention of biofilm formation and carbonate deposition in drinking water systems. ULTRASONICS SONOCHEMISTRY 2019; 52:41-49. [PMID: 30718177 DOI: 10.1016/j.ultsonch.2018.10.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 10/04/2018] [Accepted: 10/21/2018] [Indexed: 06/09/2023]
Abstract
A device generating low-frequency and low-intensity ultrasound waves was used for mitigating biofilm accumulation and scaling. Two systems were tested: a lab-scale plate heat exchanger operated with continuously recycled water and a continually fed flow-through drinking water pilot used for mimicking water circulation in pipes. Initial deposition of bacterial cells was not prevented by ultrasound wave treatment. However, whatever the tested system, both further calcium carbonate deposition and biofilm growth were markedly inhibited. Biofilms formed in reactors subjected to low-frequency and low-intensity ultrasound waves were weakly attached to the material. Even though the activity of bacteria was affected as shown by their lower cultivability, membrane permeability did not appear compromised. Ultrasound technology sounds very promising in both the mitigation of drinking water biofilm and carbonate accumulation.
Collapse
Affiliation(s)
- Laurence Mathieu
- EPHE, PSL Research University, UMR 7564, LCPME, F-54500 Vandoeuvre-lès-Nancy, France.
| | - Anaïs Keraval
- Lorraine University, CNRS, UMR 7564, LCPME, F-54600 Villers-lès-Nancy, France
| | - Nico F Declercq
- Georgia Institute of Technology, UMI Georgia Tech - CNRS 2958, F-57070 Metz, France
| | - Jean-Claude Block
- Lorraine University, CNRS, UMR 7564, LCPME, F-54600 Villers-lès-Nancy, France
| |
Collapse
|
20
|
El-Chakhtoura J, Saikaly PE, van Loosdrecht MCM, Vrouwenvelder JS. Impact of Distribution and Network Flushing on the Drinking Water Microbiome. Front Microbiol 2018; 9:2205. [PMID: 30283424 PMCID: PMC6157312 DOI: 10.3389/fmicb.2018.02205] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 08/29/2018] [Indexed: 11/30/2022] Open
Abstract
We sampled the tap water of seven unique, full-scale drinking water distribution systems at different locations as well as the corresponding treatment plant effluents to evaluate the impact of distribution and the potential presence of a core drinking water microbiome. The water was also sampled during network flushing to examine its effect on the microbial ecology. While a core microbiome dominated by Gammaproteobacteria was found using 16S rRNA gene pyrosequencing, an increase in biomass was detected in the networks, especially during flushing. Water age did not significantly impact the microbiology. Irrespective of differences in treatment plants, tap water bacterial communities in the distinct networks converged and highly resembled the flushed water communities. Piping biofilm and sediment communities therefore largely determine the final tap water microbial quality, attenuating the impact of water source and treatment strategy and highlighting the fundamental role of local physicochemical conditions and microbial processes within infrastructure micro-niches.
Collapse
Affiliation(s)
- Joline El-Chakhtoura
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, Netherlands.,Water Desalination and Reuse Center, Division of Biological and Environmental Science and Engineering, King Abdullah University of Science and Technology, Jeddah, Saudi Arabia
| | - Pascal E Saikaly
- Water Desalination and Reuse Center, Division of Biological and Environmental Science and Engineering, King Abdullah University of Science and Technology, Jeddah, Saudi Arabia
| | - Mark C M van Loosdrecht
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, Netherlands
| | - Johannes S Vrouwenvelder
- Department of Biotechnology, Faculty of Applied Sciences, Delft University of Technology, Delft, Netherlands.,Water Desalination and Reuse Center, Division of Biological and Environmental Science and Engineering, King Abdullah University of Science and Technology, Jeddah, Saudi Arabia
| |
Collapse
|
21
|
Towards standardized mechanical characterization of microbial biofilms: analysis and critical review. NPJ Biofilms Microbiomes 2018; 4:17. [PMID: 30131867 PMCID: PMC6102240 DOI: 10.1038/s41522-018-0062-5] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 06/28/2018] [Accepted: 06/28/2018] [Indexed: 02/05/2023] Open
Abstract
Developing reliable anti-biofilm strategies or efficient biofilm-based bioprocesses strongly depends on having a clear understanding of the mechanisms underlying biofilm development, and knowledge of the relevant mechanical parameters describing microbial biofilm behavior. Many varied mechanical testing methods are available to assess these parameters. The mechanical properties thus identified can then be used to compare protocols such as antibiotic screening. However, the lack of standardization in both mechanical testing and the associated identification methods for a given microbiological goal remains a blind spot in the biofilm community. The pursuit of standardization is problematic, as biofilms are living structures, i.e., both complex and dynamic. Here, we review the main available methods for characterizing the mechanical properties of biofilms through the lens of the relationship linking experimental testing to the identification of mechanical parameters. We propose guidelines for characterizing biofilms according to microbiological objectives that will help the reader choose an appropriate test and a relevant identification method for measuring any given mechanical parameter. The use of a common methodology for the mechanical characterization of biofilms will enable reliable analysis and comparison of microbiological protocols needed for improvement of engineering process and screening.
Collapse
|
22
|
Perrin A, Herbelin P, Jorand FPA, Skali-Lami S, Mathieu L. Design of a rotating disk reactor to assess the colonization of biofilms by free-living amoebae under high shear rates. BIOFOULING 2018; 34:368-377. [PMID: 29745778 DOI: 10.1080/08927014.2018.1444756] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 02/20/2018] [Indexed: 06/08/2023]
Abstract
The present study was aimed at designing and optimizing a rotating disk reactor simulating high hydrodynamic shear rates (γ), which are representative of cooling circuits. The characteristics of the hydrodynamic conditions in the reactor and the complex approach used to engineer it are described. A 60 l tank was filled with freshwater containing free-living amoebae (FLA) and bacteria. Adhesion of the bacteria and formation of a biofilm on the stainless steel coupons were observed. FLA were able to establish in these biofilms under γ as high as 85,000 s-1. Several physical mechanisms (convection, diffusion, sedimentation) could explain the accumulation of amoeboid cells on surfaces, but further research is required to fully understand and model the fine mechanisms governing such transport under γ similar to those encountered in the industrial environment. This technological advance may enable research into these topics.
Collapse
Affiliation(s)
- A Perrin
- a Université de Lorraine, CNRS, LCPME , F-54000 Nancy , France
- b EDF Recherche et Développement, Laboratoire National d'Hydraulique et Environnement , F-78401 Chatou , France
| | - P Herbelin
- b EDF Recherche et Développement, Laboratoire National d'Hydraulique et Environnement , F-78401 Chatou , France
| | - F P A Jorand
- a Université de Lorraine, CNRS, LCPME , F-54000 Nancy , France
| | - S Skali-Lami
- c Université de Lorraine, CNRS, LEMTA , F-54000 Nancy , France
| | - L Mathieu
- a Université de Lorraine, CNRS, LCPME , F-54000 Nancy , France
- d EPHE, PSL Research University, LCPME , F-54000 Nancy , France
| |
Collapse
|
23
|
Montoya-Pachongo C, Douterelo I, Noakes C, Camargo-Valero MA, Sleigh A, Escobar-Rivera JC, Torres-Lozada P. Field assessment of bacterial communities and total trihalomethanes: Implications for drinking water networks. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 616-617:345-354. [PMID: 29126052 DOI: 10.1016/j.scitotenv.2017.10.254] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 10/22/2017] [Accepted: 10/24/2017] [Indexed: 06/07/2023]
Abstract
Operation and maintenance (O&M) of drinking water distribution networks (DWDNs) in tropical countries simultaneously face the control of acute and chronic risks due to the presence of microorganisms and disinfection by-products, respectively. In this study, results from a detailed field characterization of microbiological, chemical and infrastructural parameters of a tropical-climate DWDN are presented. Water physicochemical parameters and the characteristics of the network were assessed to evaluate the relationship between abiotic and microbiological factors and their association with the presence of total trihalomethanes (TTHMs). Illumina sequencing of the bacterial 16s rRNA gene revealed significant differences in the composition of biofilm and planktonic communities. The highly diverse biofilm communities showed the presence of methylotrophic bacteria, which suggest the presence of methyl radicals such as THMs within this habitat. Microbiological parameters correlated with water age, pH, temperature and free residual chlorine. The results from this study are necessary to increase the awareness of O&M practices in DWDNs required to reduce biofilm formation and maintain appropriate microbiological and chemical water quality, in relation to biofilm detachment and DBP formation.
Collapse
Affiliation(s)
- Carolina Montoya-Pachongo
- Institute for Public Health and Environmental Engineering (iPHEE), School of Civil Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK.
| | - Isabel Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, The University of Sheffield, Mappin St., Sheffield S1 3JD, UK
| | - Catherine Noakes
- Institute for Public Health and Environmental Engineering (iPHEE), School of Civil Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | - Miller Alonso Camargo-Valero
- Institute for Public Health and Environmental Engineering (iPHEE), School of Civil Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK; Departamento de Ingeniería Química, Universidad Nacional de Colombia, Campus La Nubia, Manizales, Colombia
| | - Andrew Sleigh
- Institute for Public Health and Environmental Engineering (iPHEE), School of Civil Engineering, University of Leeds, Woodhouse Lane, Leeds LS2 9JT, UK
| | | | - Patricia Torres-Lozada
- Grupo de Investigación Estudio y Control de la Contaminación Ambiental (ECCA), Universidad del Valle, Calle 13 No. 100-00, Cali, Colombia
| |
Collapse
|
24
|
Tsagkari E, Sloan WT. Turbulence accelerates the growth of drinking water biofilms. Bioprocess Biosyst Eng 2018; 41:757-770. [PMID: 29428998 PMCID: PMC5958169 DOI: 10.1007/s00449-018-1909-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Accepted: 02/06/2018] [Indexed: 11/14/2022]
Abstract
Biofilms are found at the inner surfaces of drinking water pipes and, therefore, it is essential to understand biofilm processes to control their formation. Hydrodynamics play a crucial role in shaping biofilms. Thus, knowing how biofilms form, develop and disperse under different flow conditions is critical in the successful management of these systems. Here, the development of biofilms after 4 weeks, the initial formation of biofilms within 10 h and finally, the response of already established biofilms within 24-h intervals in which the flow regime was changed, were studied using a rotating annular reactor under three different flow regimes: turbulent, transition and laminar. Using fluorescence microscopy, information about the number of microcolonies on the reactor slides, the surface area of biofilms and of extracellular polymeric substances and the biofilm structures was acquired. Gravimetric measurements were conducted to characterise the thickness and density of biofilms, and spatial statistics were used to characterise the heterogeneity and spatial correlation of biofilm structures. Contrary to the prevailing view, it was shown that turbulent flow did not correlate with a reduction in biofilms; turbulence was found to enhance both the initial formation and the development of biofilms on the accessible surfaces. Additionally, after 24-h changes of the flow regime it was indicated that biofilms responded to the quick changes of the flow regime. Overall, this work suggests that different flow conditions can cause substantial changes in biofilm morphology and growth and specifically that turbulent flow can accelerate biofilm growth in drinking water.
Collapse
Affiliation(s)
- E Tsagkari
- College of Science and Engineering, School of Engineering, University of Glasgow, Glasgow, G12 8LT, UK.
| | - W T Sloan
- College of Science and Engineering, School of Engineering, University of Glasgow, Glasgow, G12 8LT, UK
| |
Collapse
|
25
|
Meyers G, Kapelan Z, Keedwell E. Short-term forecasting of turbidity in trunk main networks. WATER RESEARCH 2017; 124:67-76. [PMID: 28750286 DOI: 10.1016/j.watres.2017.07.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 06/20/2017] [Accepted: 07/15/2017] [Indexed: 06/07/2023]
Abstract
Water discolouration is an increasingly important and expensive issue due to rising customer expectations, tighter regulatory demands and ageing Water Distribution Systems (WDSs) in the UK and abroad. This paper presents a new turbidity forecasting methodology capable of aiding operational staff and enabling proactive management strategies. The turbidity forecasting methodology developed here is completely data-driven and does not require hydraulic or water quality network model that is expensive to build and maintain. The methodology is tested and verified on a real trunk main network with observed turbidity measurement data. Results obtained show that the methodology can detect if discolouration material is mobilised, estimate if sufficient turbidity will be generated to exceed a preselected threshold and approximate how long the material will take to reach the downstream meter. Classification based forecasts of turbidity can be reliably made up to 5 h ahead although at the expense of increased false alarm rates. The methodology presented here could be used as an early warning system that can enable a multitude of cost beneficial proactive management strategies to be implemented as an alternative to expensive trunk mains cleaning programs.
Collapse
Affiliation(s)
- Gregory Meyers
- College of Engineering, Mathematics and Physical Sciences, University of Exeter, North Park Road, Exeter, EX4 4QF, UK.
| | - Zoran Kapelan
- College of Engineering, Mathematics and Physical Sciences, University of Exeter, North Park Road, Exeter, EX4 4QF, UK
| | - Edward Keedwell
- College of Engineering, Mathematics and Physical Sciences, University of Exeter, North Park Road, Exeter, EX4 4QF, UK
| |
Collapse
|
26
|
Comparison of biofilm cell quantification methods for drinking water distribution systems. J Microbiol Methods 2017; 144:8-21. [PMID: 29111400 DOI: 10.1016/j.mimet.2017.10.013] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 10/21/2017] [Accepted: 10/25/2017] [Indexed: 01/24/2023]
Abstract
Drinking water quality typically degrades after treatment during conveyance through the distribution system. Potential causes include biofilm growth in distribution pipes which may result in pathogen retention, inhibited disinfectant diffusion, and proliferation of bad tastes and odors. However, there is no standard method for direct measurement of biofilms or quantification of biofilm cells in drinking water distribution systems. Three methods are compared here for quantification of biofilm cells grown in pipe loops samplers: biofilm heterotrophic plate count (HPC), biofilm biovolume by confocal laser scanning microscopy (CLSM) and biofilm total cell count by flow cytometry (FCM) paired with Syto 9. Both biofilm biovolume by CLSM and biofilm total cell count by FCM were evaluated for quantification of the whole biofilms (including non-viable cells and viable but not culturable cells). Signal-to-background ratios and overall performance of biofilm biovolume by CLSM and biofilm total cell count by FCM were found to vary with the pipe material. Biofilm total cell count by FCM had a low signal-to-background ratio on all materials, indicating that further development is recommended before application in drinking water environments. Biofilm biovolume by CLSM showed the highest signal-to-background ratio for cement and cast iron, which suggests promise for wider application in full-scale systems. Biofilm biovolume by CLSM and Syto 9 staining allowed in-situ biofilm cell quantification thus elimination variable associated with cell detachment for quantification but had limitations associated with non-specific staining of cement and, to a lesser degree, auto-fluorescence of both cement and polyvinyl chloride materials. Due to variability in results obtained from each method, multiple methods are recommended to assess biofilm growth in drinking water distribution systems. Of the methods investigated here, HPC and CLSM and recommended for further development towards application in full-scale systems. HPC is a sample and widely applied method that quantifies viable culturable cells. CLSM analysis allows the elimination of experimental variables associated with cell detachment and affords the opportunity to evaluate biofilm components such as extracellular polymeric substances through the addition of specific probes. These two methods can be applied together to assess biofilms known to degrade treated water quality during conveyance in full-scale drinking water treatment systems. The significance of improved biofilm assessment methods for drinking water distribution systems lies in advancing understanding of biofilm growth and control mechanisms that may lead to improved water quality during conveyance and at the tap for greater public health protection.
Collapse
|
27
|
Fish K, Osborn AM, Boxall JB. Biofilm structures (EPS and bacterial communities) in drinking water distribution systems are conditioned by hydraulics and influence discolouration. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 593-594:571-580. [PMID: 28360007 DOI: 10.1016/j.scitotenv.2017.03.176] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 03/13/2017] [Accepted: 03/19/2017] [Indexed: 06/07/2023]
Abstract
High-quality drinking water from treatment works is degraded during transport to customer taps through the Drinking Water Distribution System (DWDS). Interactions occurring at the pipe wall-water interface are central to this degradation and are often dominated by complex microbial biofilms that are not well understood. This study uses novel application of confocal microscopy techniques to quantify the composition of extracellular polymeric substances (EPS) and cells of DWDS biofilms together with concurrent evaluation of the bacterial community. An internationally unique, full-scale, experimental DWDS facility was used to investigate the impact of three different hydraulic patterns upon biofilms and subsequently assess their response to increases in shear stress, linking biofilms to water quality impacts such as discolouration. Greater flow variation during growth was associated with increased cell quantity but was inversely related to EPS-to-cell volume ratios and bacterial diversity. Discolouration was caused and EPS was mobilised during flushing of all conditions. Ultimately, biofilms developed under low-varied flow conditions had lowest amounts of biomass, the greatest EPS volumes per cell and the lowest discolouration response. This research shows that the interactions between hydraulics and biofilm physical and community structures are complex but critical to managing biofilms within ageing DWDS infrastructure to limit water quality degradation and protect public health.
Collapse
Affiliation(s)
- K Fish
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield S1 3JD, UK; NERC Biomolecular Analysis Facility, Department of Animal and Plant Sciences, Western Bank, Sheffield S10 2TN, UK.
| | - A M Osborn
- Biosciences and Food Technology Discipline, School of Science, RMIT University, PO Box 71, Bundoora, Melbourne VIC3083, Australia
| | - J B Boxall
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield S1 3JD, UK
| |
Collapse
|
28
|
Husband S, Boxall J. Understanding and managing discolouration risk in trunk mains. WATER RESEARCH 2016; 107:127-140. [PMID: 27837730 DOI: 10.1016/j.watres.2016.10.049] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Revised: 08/24/2016] [Accepted: 10/19/2016] [Indexed: 06/06/2023]
Abstract
There is currently no accepted concept or approach for understanding and controlling discolouration risk associated with trunk mains. This paper assesses the applicability of cohesive layer theories to manage discolouration and a steady state empirical modelling tool that describes the process of particulate material accumulation. Results are presented from independent field experiments across the UK and internationally that evidence hydraulically induced mobilisation, or effectively cleaning, once imposed system shear stress exceeds normal conditions. Model calibration to measured data validates the cohesive layer concept with transferability in empirically derived parameters demonstrating a viable operational planning tool. The experiments highlight the accumulation of material layers as a continuous and ubiquitous process, such that fully clean pipes can never exist and helping explain how discolouration risk changes over time. A major practical implication of the novel understanding demonstrated in this paper is that discolouration risk in trunk mains can be simply managed by pro-active strategies that regularly vary the hydraulic conditions. This avoids the need for disruptive and expensive out of service invasive interventions yet offers operators a cost-effective long-term strategy to safeguard water quality.
Collapse
Affiliation(s)
- S Husband
- Department of Civil and Structural Engineering, University of Sheffield, Sheffield, S1 3JD, UK.
| | - J Boxall
- Department of Civil and Structural Engineering, University of Sheffield, Sheffield, S1 3JD, UK
| |
Collapse
|
29
|
Mathieu L, Francius G, El Zein R, Angel E, Block JC. Bacterial repopulation of drinking water pipe walls after chlorination. BIOFOULING 2016; 32:925-934. [PMID: 27483985 DOI: 10.1080/08927014.2016.1212989] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Accepted: 07/05/2016] [Indexed: 06/06/2023]
Abstract
The short-term kinetics of bacterial repopulation were evaluated after chlorination of high-density polyethylene (HDPE) colonized with drinking water biofilms and compared with bare HDPE surfaces. The effect of chlorination was partial as a residual biofilm persisted and was time-limited as repopulation occurred immediately after water resupply. The total number of bacteria reached the same levels on both the bare and chlorinated biofilm-fouled HDPE after a seven-day exposure to drinking water. Due to the presence of a residual biofilm, the hydrophobicity of chlorinated biofilm-fouled surface exhibited much lower adhesion forces (2.1 nN) compared to bare surfaces (8.9 nN). This could explain the rapid repopulation after chlorination, with a twofold faster bacterial accumulation rate on the bare HDPE surface. γ-Proteobacteria dominated the early stages of repopulation of both surfaces and a shift in the dominance occurred over the colonization time. Such observations define a timescale for cleaning frequency in industrial environments and guidelines for a rinsing procedure using drinking water.
Collapse
Affiliation(s)
- Laurence Mathieu
- a EPHE , PSL Research University, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement, LCPME , UMR 7564 , Nancy , France
| | - Grégory Francius
- b CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement, LCPME , UMR 7564 , Nancy , France
| | - Racha El Zein
- b CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement, LCPME , UMR 7564 , Nancy , France
| | - Edith Angel
- a EPHE , PSL Research University, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement, LCPME , UMR 7564 , Nancy , France
| | - Jean-Claude Block
- b CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement, LCPME , UMR 7564 , Nancy , France
| |
Collapse
|
30
|
Douterelo I, Husband S, Loza V, Boxall J. Dynamics of Biofilm Regrowth in Drinking Water Distribution Systems. Appl Environ Microbiol 2016; 82:4155-4168. [PMID: 27208119 PMCID: PMC4959196 DOI: 10.1128/aem.00109-16] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 04/27/2016] [Indexed: 12/16/2022] Open
Abstract
UNLABELLED The majority of biomass within water distribution systems is in the form of attached biofilm. This is known to be central to drinking water quality degradation following treatment, yet little understanding of the dynamics of these highly heterogeneous communities exists. This paper presents original information on such dynamics, with findings demonstrating patterns of material accumulation, seasonality, and influential factors. Rigorous flushing operations repeated over a 1-year period on an operational chlorinated system in the United Kingdom are presented here. Intensive monitoring and sampling were undertaken, including time-series turbidity and detailed microbial analysis using 16S rRNA Illumina MiSeq sequencing. The results show that bacterial dynamics were influenced by differences in the supplied water and by the material remaining attached to the pipe wall following flushing. Turbidity, metals, and phosphate were the main factors correlated with the distribution of bacteria in the samples. Coupled with the lack of inhibition of biofilm development due to residual chlorine, this suggests that limiting inorganic nutrients, rather than organic carbon, might be a viable component in treatment strategies to manage biofilms. The research also showed that repeat flushing exerted beneficial selective pressure, giving another reason for flushing being a viable advantageous biofilm management option. This work advances our understanding of microbiological processes in drinking water distribution systems and helps inform strategies to optimize asset performance. IMPORTANCE This research provides novel information regarding the dynamics of biofilm formation in real drinking water distribution systems made of different materials. This new knowledge on microbiological process in water supply systems can be used to optimize the performance of the distribution network and to guarantee safe and good-quality drinking water to consumers.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| | - S Husband
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| | - V Loza
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| | - J Boxall
- Pennine Water Group, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
31
|
Daniels SL, Pressman JG, Wahman DG. AFM structural characterization of drinking water biofilm under physiological conditions. RSC Adv 2016. [DOI: 10.1039/c5ra20606e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Insights into the complex morphology of multi-species drinking water biofilm using atomic force microscopy (AFM).
Collapse
Affiliation(s)
- Stephanie L. Daniels
- Oak Ridge Institute for Science and Education
- Oak Ridge
- USA
- Water Supply and Water Resource Division
- National Risk Management Research Laboratory
| | - Jonathan G. Pressman
- Water Supply and Water Resource Division
- National Risk Management Research Laboratory
- U.S. Environmental Protection Agency
- Cincinnati
- USA
| | - David G. Wahman
- Water Supply and Water Resource Division
- National Risk Management Research Laboratory
- U.S. Environmental Protection Agency
- Cincinnati
- USA
| |
Collapse
|
32
|
Mechanics of Bacterial Cells and Initial Surface Colonisation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2016; 915:245-60. [DOI: 10.1007/978-3-319-32189-9_15] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
33
|
Abou Neel EA, Bozec L, Perez RA, Kim HW, Knowles JC. Nanotechnology in dentistry: prevention, diagnosis, and therapy. Int J Nanomedicine 2015; 10:6371-94. [PMID: 26504385 PMCID: PMC4605240 DOI: 10.2147/ijn.s86033] [Citation(s) in RCA: 66] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Nanotechnology has rapidly expanded into all areas of science; it offers significant alternative ways to solve scientific and medical questions and problems. In dentistry, nanotechnology has been exploited in the development of restorative materials with some significant success. This review discusses nanointerfaces that could compromise the longevity of dental restorations, and how nanotechnolgy has been employed to modify them for providing long-term successful restorations. It also focuses on some challenging areas in dentistry, eg, oral biofilm and cancers, and how nanotechnology overcomes these challenges. The recent advances in nanodentistry and innovations in oral health-related diagnostic, preventive, and therapeutic methods required to maintain and obtain perfect oral health, have been discussed. The recent advances in nanotechnology could hold promise in bringing a paradigm shift in dental field. Although there are numerous complex therapies being developed to treat many diseases, their clinical use requires careful consideration of the expense of synthesis and implementation.
Collapse
Affiliation(s)
- Ensanya Ali Abou Neel
- Division of Biomaterials, Operative Dentistry Department, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
- Biomaterials Department, Faculty of Dentistry, Tanta University, Tanta, Egypt
- UCL Eastman Dental Institute, Biomaterials and Tissue Engineering, London, UK
| | - Laurent Bozec
- UCL Eastman Dental Institute, Biomaterials and Tissue Engineering, London, UK
| | - Roman A Perez
- Institute of Tissue Regenerative Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and BK21 Plus NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, Republic of Korea
| | - Hae-Won Kim
- Institute of Tissue Regenerative Engineering (ITREN), Dankook University, Cheonan, Republic of Korea
- Department of Nanobiomedical Science and BK21 Plus NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, Republic of Korea
- Department of Biomaterials Science, College of Dentistry, Dankook University, Cheonan, Republic of Korea
| | - Jonathan C Knowles
- UCL Eastman Dental Institute, Biomaterials and Tissue Engineering, London, UK
- Department of Nanobiomedical Science and BK21 Plus NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, Republic of Korea
| |
Collapse
|
34
|
Interfacial separation of a mature biofilm from a glass surface - A combined experimental and cohesive zone modelling approach. J Mech Behav Biomed Mater 2015; 54:205-18. [PMID: 26474034 DOI: 10.1016/j.jmbbm.2015.09.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2015] [Revised: 09/11/2015] [Accepted: 09/13/2015] [Indexed: 11/20/2022]
Abstract
A good understanding of the mechanical stability of biofilms is essential for biofouling management, particularly when mechanical forces are used. Previous biofilm studies lack a damage-based theoretical model to describe the biofilm separation from a surface. The purpose of the current study was to investigate the interfacial separation of a mature biofilm from a rigid glass substrate using a combined experimental and numerical modelling approach. In the current work, the biofilm-glass interfacial separation process was investigated under tensile and shear stresses at the macroscale level, known as modes I and II failure mechanisms respectively. The numerical simulations were performed using a Finite Volume (FV)-based simulation package (OpenFOAM®) to predict the separation initiation using the cohesive zone model (CZM). Atomic force microscopy (AFM)-based retraction curve was used to obtain the separation properties between the biofilm and glass colloid at microscale level, where the CZM parameters were estimated using the Johnson-Kendall-Roberts (JKR) model. In this study CZM is introduced as a reliable method for the investigation of interfacial separation between a biofilm and rigid substrate, in which a high local stress at the interface edge acts as an ultimate stress at the crack tip.This study demonstrated that the total interfacial failure energy measured at the macroscale, was significantly higher than the pure interfacial separation energy obtained by AFM at the microscale, indicating a highly ductile deformation behaviour within the bulk biofilm matrix. The results of this study can significantly contribute to the understanding of biofilm detachments.
Collapse
|
35
|
Characterisation of the physical composition and microbial community structure of biofilms within a model full-scale drinking water distribution system. PLoS One 2015; 10:e0115824. [PMID: 25706303 PMCID: PMC4338064 DOI: 10.1371/journal.pone.0115824] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Accepted: 12/02/2014] [Indexed: 11/19/2022] Open
Abstract
Within drinking water distribution systems (DWDS), microorganisms form multi-species biofilms on internal pipe surfaces. A matrix of extracellular polymeric substances (EPS) is produced by the attached community and provides structure and stability for the biofilm. If the EPS adhesive strength deteriorates or is overcome by external shear forces, biofilm is mobilised into the water potentially leading to degradation of water quality. However, little is known about the EPS within DWDS biofilms or how this is influenced by community composition or environmental parameters, because of the complications in obtaining biofilm samples and the difficulties in analysing EPS. Additionally, although biofilms may contain various microbial groups, research commonly focuses solely upon bacteria. This research applies an EPS analysis method based upon fluorescent confocal laser scanning microscopy (CLSM) in combination with digital image analysis (DIA), to concurrently characterize cells and EPS (carbohydrates and proteins) within drinking water biofilms from a full-scale DWDS experimental pipe loop facility with representative hydraulic conditions. Application of the EPS analysis method, alongside DNA fingerprinting of bacterial, archaeal and fungal communities, was demonstrated for biofilms sampled from different positions around the pipeline, after 28 days growth within the DWDS experimental facility. The volume of EPS was 4.9 times greater than that of the cells within biofilms, with carbohydrates present as the dominant component. Additionally, the greatest proportion of EPS was located above that of the cells. Fungi and archaea were established as important components of the biofilm community, although bacteria were more diverse. Moreover, biofilms from different positions were similar with respect to community structure and the quantity, composition and three-dimensional distribution of cells and EPS, indicating that active colonisation of the pipe wall is an important driver in material accumulation within the DWDS.
Collapse
|
36
|
Aguayo S, Donos N, Spratt D, Bozec L. Single-bacterium nanomechanics in biomedicine: unravelling the dynamics of bacterial cells. NANOTECHNOLOGY 2015; 26:062001. [PMID: 25598514 DOI: 10.1088/0957-4484/26/6/062001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The use of the atomic force microscope (AFM) in microbiology has progressed significantly throughout the years since its first application as a high-resolution imaging instrument. Modern AFM setups are capable of characterizing the nanomechanical behaviour of bacterial cells at both the cellular and molecular levels, where elastic properties and adhesion forces of single bacterium cells can be examined under different experimental conditions. Considering that bacterial and biofilm-mediated infections continue to challenge the biomedical field, it is important to understand the biophysical events leading towards bacterial adhesion and colonization on both biological and non-biological substrates. The purpose of this review is to present the latest findings concerning the field of single-bacterium nanomechanics, and discuss future trends and applications of nanoindentation and single-cell force spectroscopy techniques in biomedicine.
Collapse
Affiliation(s)
- S Aguayo
- Department of Biomaterials and Tissue Engineering, UCL Eastman Dental Institute, University College London, London, UK
| | | | | | | |
Collapse
|
37
|
Gomes IB, Simões M, Simões LC. An overview on the reactors to study drinking water biofilms. WATER RESEARCH 2014; 62:63-87. [PMID: 24937357 DOI: 10.1016/j.watres.2014.05.039] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 05/21/2014] [Accepted: 05/22/2014] [Indexed: 06/03/2023]
Abstract
The development of biofilms in drinking water distribution systems (DWDS) can cause pipe degradation, changes in the water organoleptic properties but the main problem is related to the public health. Biofilms are the main responsible for the microbial presence in drinking water (DW) and can be reservoirs for pathogens. Therefore, the understanding of the mechanisms underlying biofilm formation and behavior is of utmost importance in order to create effective control strategies. As the study of biofilms in real DWDS is difficult, several devices have been developed. These devices allow biofilm formation under controlled conditions of physical (flow velocity, shear stress, temperature, type of pipe material, etc), chemical (type and amount of nutrients, type of disinfectant and residuals, organic and inorganic particles, ions, etc) and biological (composition of microbial community - type of microorganism and characteristics) parameters, ensuring that the operational conditions are similar as possible to the DWDS conditions in order to achieve results that can be applied to the real scenarios. The devices used in DW biofilm studies can be divided essentially in two groups, those usually applied in situ and the bench top laboratorial reactors. The selection of a device should be obviously in accordance with the aim of the study and its advantages and limitations should be evaluated to obtain reproducible results that can be transposed into the reality of the DWDS. The aim of this review is to provide an overview on the main reactors used in DW biofilm studies, describing their characteristics and applications, taking into account their main advantages and limitations.
Collapse
Affiliation(s)
- I B Gomes
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - M Simões
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - L C Simões
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal; CEB - Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal.
| |
Collapse
|
38
|
|
39
|
Mathieu L, Bertrand I, Abe Y, Angel E, Block JC, Skali-Lami S, Francius G. Drinking water biofilm cohesiveness changes under chlorination or hydrodynamic stress. WATER RESEARCH 2014; 55:175-184. [PMID: 24607313 DOI: 10.1016/j.watres.2014.01.054] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 12/28/2013] [Accepted: 01/25/2014] [Indexed: 06/03/2023]
Abstract
Attempts at removal of drinking water biofilms rely on various preventive and curative strategies such as nutrient reduction in drinking water, disinfection or water flushing, which have demonstrated limited efficiency. The main reason for these failures is the cohesiveness of the biofilm driven by the physico-chemical properties of its exopolymeric matrix (EPS). Effective cleaning procedures should break up the matrix and/or change the elastic properties of bacterial biofilms. The aim of this study was to evaluate the change in the cohesive strength of two-month-old drinking water biofilms under increasing hydrodynamic shear stress τw (from ∼0.2 to ∼10 Pa) and shock chlorination (applied concentration at T0: 10 mg Cl2/L; 60 min contact time). Biofilm erosion (cell loss per unit surface area) and cohesiveness (changes in the detachment shear stress and cluster volumes measured by atomic force microscopy (AFM)) were studied. When rapidly increasing the hydrodynamic constraint, biofilm removal was found to be dependent on a dual process of erosion and coalescence of the biofilm clusters. Indeed, 56% of the biofilm cells were removed with, concomitantly, a decrease in the number of the 50-300 μm(3) clusters and an increase in the number of the smaller (i.e., <50 μm(3)) and larger (i.e., >600 μm(3)) ones. Moreover, AFM evidenced the strengthening of the biofilm structure along with the doubling of the number of contact points, NC, per cluster volume unit following the hydrodynamic disturbance. This suggests that the compactness of the biofilm exopolymers increases with hydrodynamic stress. Shock chlorination removed cells (-75%) from the biofilm while reducing the volume of biofilm clusters. Oxidation stress resulted in a decrease in the cohesive strength profile of the remaining drinking water biofilms linked to a reduction in the number of contact points within the biofilm network structure in particular for the largest biofilm cluster volumes (>200 μm(3)). Changes in the cohesive strength of drinking water biofilms subsequent to cleaning/disinfection operations call into question the effectiveness of cleaning-in-place procedures. The combined alternating use of oxidation and shear stress sequences needs to be investigated as it could be an important adjunct to improving biofilm removal/reduction procedures.
Collapse
Affiliation(s)
- L Mathieu
- Ecole Pratique des Hautes Etudes (EPHE), LCPME, UMR 7564 CNRS - Université de Lorraine, Nancy, France.
| | - I Bertrand
- CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME), UMR 7564, Nancy, France
| | - Y Abe
- CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME), UMR 7564, Nancy, France
| | - E Angel
- Ecole Pratique des Hautes Etudes (EPHE), LCPME, UMR 7564 CNRS - Université de Lorraine, Nancy, France
| | - J C Block
- CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME), UMR 7564, Nancy, France
| | - S Skali-Lami
- CNRS and Université de Lorraine, Laboratoire d'Energétique et de Mécanique Théorique et Appliquée (LEMTA), UMR 7563, Nancy, France
| | - G Francius
- CNRS and Université de Lorraine, Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME), UMR 7564, Nancy, France
| |
Collapse
|
40
|
Douterelo I, Husband S, Boxall JB. The bacteriological composition of biomass recovered by flushing an operational drinking water distribution system. WATER RESEARCH 2014; 54:100-114. [PMID: 24565801 DOI: 10.1016/j.watres.2014.01.049] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 01/23/2014] [Accepted: 01/26/2014] [Indexed: 06/03/2023]
Abstract
This study investigates the influence of pipe characteristics on the bacteriological composition of material mobilised from a drinking water distribution system (DWDS) and the impact of biofilm removal on water quality. Hydrants in a single UK Distribution Management Area (DMA) with both polyethylene and cast iron pipe sections were subjected to incremental increases in flow to mobilise material from the pipe walls. Turbidity was monitored during these operations and water samples were collected for physico-chemical and bacteriological analysis. DNA was extracted from the material mobilised into the bulk water before and during flushing. Bacterial tag-encoded 454 pyrosequencing was then used to characterize the bacterial communities present in this material. Turbidity values were high in the samples from cast iron pipes. Iron, aluminium, manganese and phosphate concentrations were found to correlate to observed turbidity. The bacterial community composition of the material mobilised from the pipes was significantly different between plastic and cast iron pipe sections (p < 0.5). High relative abundances of Alphaproteobacteria (23.3%), Clostridia (10.3%) and Actinobacteria (10.3%) were detected in the material removed from plastic pipes. Sequences related to Alphaproteobacteria (22.8%), Bacilli (16.6%), and Gammaproteobacteria (1.4%) were predominant in the samples obtained from cast iron pipes. The highest species richness and diversity were found in the samples from material mobilised from plastic pipes. Spirochaeta spp., Methylobacterium spp. Clostridium spp. and Desulfobacterium spp., were the most represented genera in the material obtained prior to and during the flushing of the plastic pipes. In cast iron pipes a high relative abundance of bacteria able to utilise different iron and manganese compounds were found such as Lysinibacillus spp., Geobacillus spp. and Magnetobacterium spp.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield S1 3JD, UK.
| | - S Husband
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield S1 3JD, UK
| | - J B Boxall
- Pennine Water Group, Department of Civil and Structural Engineering, Sir Frederick Mappin Building, University of Sheffield, Sheffield S1 3JD, UK
| |
Collapse
|
41
|
Douterelo I, Sharpe R, Boxall J. Bacterial community dynamics during the early stages of biofilm formation in a chlorinated experimental drinking water distribution system: implications for drinking water discolouration. J Appl Microbiol 2014; 117:286-301. [PMID: 24712449 PMCID: PMC4282425 DOI: 10.1111/jam.12516] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2013] [Revised: 03/19/2014] [Accepted: 04/01/2014] [Indexed: 12/01/2022]
Abstract
Aims To characterize bacterial communities during the early stages of biofilm formation and their role in water discolouration in a fully representative, chlorinated, experimental drinking water distribution systems (DWDS). Methods and Results Biofilm development was monitored in an experimental DWDS over 28 days; subsequently the system was disturbed by raising hydraulic conditions to simulate pipe burst, cleaning or other system conditions. Biofilm cell cover was monitored by fluorescent microscopy and a fingerprinting technique used to assess changes in bacterial community. Selected samples were analysed by cloning and sequencing of the 16S rRNA gene. Fingerprinting analysis revealed significant changes in the bacterial community structure over time (P < 0·05). Cell coverage increased over time accompanied by an increase in bacterial richness and diversity. Conclusions Shifts in the bacterial community structure were observed along with an increase in cell coverage, bacterial richness and diversity. Species related to Pseudomonas spp. and Janthinobacterium spp. dominated the process of initial attachment. Based on fingerprinting results, the hydraulic regimes did not affect the bacteriological composition of biofilms, but they did influence their mechanical stability. Significance and Importance of the Study This study gives a better insight into the early stages of biofilm formation in DWDS and will contribute to the improvement of management strategies to control the formation of biofilms and the risk of discolouration.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, University of Sheffield, Sheffield, UK
| | | | | |
Collapse
|
42
|
Gosselin F, Madeira LM, Juhna T, Block JC. Drinking water and biofilm disinfection by Fenton-like reaction. WATER RESEARCH 2013; 47:5631-5638. [PMID: 23866142 DOI: 10.1016/j.watres.2013.06.036] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2013] [Revised: 06/17/2013] [Accepted: 06/19/2013] [Indexed: 06/02/2023]
Abstract
A Fenton-like disinfection process was conducted with Fenton's reagent (H2O2) at pH 3 or 5 on autochthonous drinking water biofilms grown on corroded or non-corroded pipe material. The biofilm disinfection by Fenton-like oxidation was limited by the low content of iron and copper in the biomass grown on non-corroded plumbing. It was slightly improved by spiking the distribution system with some additional iron source (soluble iron II or ferrihydrite particles appeared as interesting candidates). However successful in situ disinfection of biofilms was only achieved in fully corroded cast iron pipes using H2O2 and adjusting the pH to 5. These new results provide additional support for the use of Fenton's processes for cleaning drinking water distribution systems contaminated with biological agents or organics.
Collapse
Affiliation(s)
- F Gosselin
- Université de Lorraine and CNRS, LCPME, UMR 7564, 405 rue de Vandoeuvre, 54600 Villers-lès-Nancy, France
| | | | | | | |
Collapse
|
43
|
Douterelo I, Sharpe RL, Boxall JB. Influence of hydraulic regimes on bacterial community structure and composition in an experimental drinking water distribution system. WATER RESEARCH 2013. [PMID: 23182667 DOI: 10.1016/j.watres.2012.09.053] [Citation(s) in RCA: 158] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Microbial biofilms formed on the inner-pipe surfaces of drinking water distribution systems (DWDS) can alter drinking water quality, particularly if they are mechanically detached from the pipe wall to the bulk water, such as due to changes in hydraulic conditions. Results are presented here from applying 454 pyrosequencing of the 16S ribosomal RNA (rRNA) gene to investigate the influence of different hydrological regimes on bacterial community structure and to study the potential mobilisation of material from the pipe walls to the network using a full scale, temperature-controlled experimental pipeline facility accurately representative of live DWDS. Analysis of pyrosequencing and water physico-chemical data showed that habitat type (water vs. biofilm) and hydraulic conditions influenced bacterial community structure and composition in our experimental DWDS. Bacterial community composition clearly differed between biofilms and bulk water samples. Gammaproteobacteria and Betaproteobacteria were the most abundant phyla in biofilms while Alphaproteobacteria was predominant in bulk water samples. This suggests that bacteria inhabiting biofilms, predominantly species belonging to genera Pseudomonas, Zooglea and Janthinobacterium, have an enhanced ability to express extracellular polymeric substances to adhere to surfaces and to favour co-aggregation between cells than those found in the bulk water. Highest species richness and diversity were detected in 28 days old biofilms with this being accentuated at highly varied flow conditions. Flushing altered the pipe-wall bacterial community structure but did not completely remove bacteria from the pipe walls, particularly under highly varied flow conditions, suggesting that under these conditions more compact biofilms were generated. This research brings new knowledge regarding the influence of different hydraulic regimes on the composition and structure of bacterial communities within DWDS and the implication that this might have on drinking water quality.
Collapse
Affiliation(s)
- I Douterelo
- Pennine Water Group, Department of Civil and Structural Engineering, Mappin Street, University of Sheffield, Sheffield S1 3JD, UK.
| | | | | |
Collapse
|
44
|
Pelleïeux S, Bertrand I, Skali-Lami S, Mathieu L, Francius G, Gantzer C. Accumulation of MS2, GA, and Qβ phages on high density polyethylene (HDPE) and drinking water biofilms under flow/non-flow conditions. WATER RESEARCH 2012; 46:6574-6584. [PMID: 22955017 DOI: 10.1016/j.watres.2012.07.041] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 07/17/2012] [Accepted: 07/23/2012] [Indexed: 05/27/2023]
Abstract
Accumulation of enteric viruses on surfaces within a drinking water distribution system was investigated in a reactor using three F-specific RNA bacteriophages (MS2, GA, and Qβ) as models of human pathogenic viruses. The influence of hydrodynamic versus hydrostatic conditions and the effect of the colonization of HDPE surfaces with two-month-old biofilms were assessed for virus accumulation on surfaces. In order to work under controlled laminar conditions and to study various wall shear stresses at the same time, a new rotating disc reactor was designed. Among the wall shear rates applied in the reactor (450 to 1640 s(-1)) no significant differences were observed concerning both the total number of bacteria, which was found to be around 1.7 × 10(7) cells/cm(2) and the virus concentrations on surfaces were about 3 × 10(4), 5 × 10(5) and 3 × 10(5) eq PFU/cm(2) for MS2, GA and Qβ phages, respectively. Comparison between static versus dynamic conditions revealed that both Brownian diffusion and convective diffusion were involved in the transport of these soft colloidal particles and an increase reaching about 1 log in virus concentrations measured on surfaces appeared when hydrodynamic conditions where applied. Our results also showed the influence of the colonization by two-month-old drinking water biofilms which led to a change in the level of virus adhesion. The implication of the physico-chemical properties was also underlined since different adhesion profiles were obtained for the three bacteriophages and MS2 phage was found to be the less adherent one whatever the conditions applied.
Collapse
Affiliation(s)
- Sandra Pelleïeux
- Laboratoire de Chimie Physique et Microbiologie pour l'Environnement (LCPME), UMR 7564 CNRS-Université de Lorraine, Nancy, France
| | | | | | | | | | | |
Collapse
|