1
|
Sudarshan AS, Dai Z, Gabrielli M, Oosthuizen-Vosloo S, Konstantinidis KT, Pinto AJ. New Drinking Water Genome Catalog Identifies a Globally Distributed Bacterial Genus Adapted to Disinfected Drinking Water Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:16475-16487. [PMID: 39235268 PMCID: PMC11411728 DOI: 10.1021/acs.est.4c05086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/06/2024]
Abstract
Genome-resolved insights into the structure and function of the drinking water microbiome can advance the effective management of drinking water quality. To enable this, we constructed and curated thousands of metagenome-assembled and isolate genomes from drinking water distribution systems globally to develop a Drinking Water Genome Catalog (DWGC). The current DWGC disproportionately represents disinfected drinking water systems due to a paucity of metagenomes from nondisinfected systems. Using the DWGC, we identify core genera of the drinking water microbiome including a genus (UBA4765) within the order Rhizobiales that is frequently detected and highly abundant in disinfected drinking water systems. We demonstrate that this genus has been widely detected but incorrectly classified in previous amplicon sequencing-based investigations of the drinking water microbiome. Further, we show that a single genome variant (genomovar) within this genus is detected in 75% of drinking water systems included in this study. We propose a name for this uncultured bacterium as "Raskinella chloraquaticus" and describe the genus as "Raskinella" (endorsed by SeqCode). Metabolic annotation and modeling-based predictions indicate that this bacterium is capable of necrotrophic growth, is able to metabolize halogenated compounds, proliferates in a biofilm-based environment, and shows clear indications of disinfection-mediated selection.
Collapse
Affiliation(s)
- Ashwin S Sudarshan
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Zihan Dai
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Marco Gabrielli
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dubendorf CH-8600, Switzerland
| | - Solize Oosthuizen-Vosloo
- Institute for Cellular and Molecular Medicine, Department of Immunology, Faculty of Health Sciences, University of Pretoria, Pretoria 0084, South Africa
| | - Konstantinos T Konstantinidis
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Ameet J Pinto
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
- School of Earth and Atmospheric Sciences, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| |
Collapse
|
2
|
Blair M, Garner E, Ji P, Pruden A. What is the Difference between Conventional Drinking Water, Potable Reuse Water, and Nonpotable Reuse Water? A Microbiome Perspective. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58. [PMID: 39258328 PMCID: PMC11428167 DOI: 10.1021/acs.est.4c04679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 08/27/2024] [Accepted: 08/27/2024] [Indexed: 09/12/2024]
Abstract
As water reuse applications expand, there is a need for more comprehensive means to assess water quality. Microbiome analysis could provide the ability to supplement fecal indicators and pathogen profiling toward defining a "healthy" drinking water microbiota while also providing insight into the impact of treatment and distribution. Here, we utilized 16S rRNA gene amplicon sequencing to identify signature features in the composition of microbiota across a wide spectrum of water types (potable conventional, potable reuse, and nonpotable reuse). A clear distinction was found in the composition of microbiota as a function of intended water use (e.g., potable vs nonpotable) across a very broad range of U.S. water systems at both the point of compliance (Betadisper p > 0.01; ANOSIM p < 0.01, r-stat = 0.71) and point of use (Betadisper p > 0.01; ANOSIM p < 0.01, r-stat = 0.41). Core and discriminatory analysis further served in identifying distinct differences between potable and nonpotable water microbiomes. Taxa were identified at both the phylum (Desulfobacterota, Patescibacteria, and Myxococcota) and genus (Aeromonas and NS11.12_marine_group) levels that effectively discriminated between potable and nonpotable waters, with the most discriminatory taxa being core/abundant in nonpotable waters (with few exceptions, such as Ralstonia being abundant in potable conventional waters). The approach and findings open the door to the possibility of microbial community signature profiling as a water quality monitoring approach for assessing efficacy of treatments and suitability of water for intended use/reuse application.
Collapse
Affiliation(s)
- Matthew
F. Blair
- Via
Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Emily Garner
- Wadsworth
Department of Civil and Environmental Engineering, West Virginia University, Morgantown, West Virginia 26506, United States
| | - Pan Ji
- Via
Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- Via
Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States
| |
Collapse
|
3
|
Dowdell KS, Olsen K, Martinez Paz EF, Sun A, Keown J, Lahr R, Steglitz B, Busch A, LiPuma JJ, Olson T, Raskin L. Investigating the suitability of online flow cytometry for monitoring full-scale drinking water ozone system disinfection effectiveness. WATER RESEARCH 2024; 257:121702. [PMID: 38749337 DOI: 10.1016/j.watres.2024.121702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 04/02/2024] [Accepted: 04/29/2024] [Indexed: 05/29/2024]
Abstract
While online monitoring of physicochemical parameters has widely been incorporated into drinking water treatment systems, online microbial monitoring has lagged behind, resulting in the use of surrogate parameters (disinfectant residual, applied dose, concentration × time, CT) to assess disinfection system performance. Online flow cytometry (online FCM) allows for automated quantification of total and intact microbial cells. This study sought to investigate the feasibility of online FCM for full-scale drinking water ozone disinfection system performance monitoring. A water treatment plant with high lime solids turbidity in the ozone contactor influent was selected to evaluate the online FCM in challenging conditions. Total and intact cell counts were monitored for 40 days and compared to surrogate parameters (ozone residual, ozone dose, and CT) and grab sample assay results for cellular adenosine triphosphate (cATP), heterotrophic plate counts (HPC), impedance flow cytometry, and 16S rRNA gene sequencing. Online FCM provided insight into the dynamics of the full-scale ozone system, including offering early warning of increased contactor effluent cell concentrations, which was not observed using surrogate measures. Positive correlations were observed between online FCM intact cell counts and cATP levels (Kendall's tau=0.40), HPC (Kendall's tau=0.20), and impedance flow cytometry results (Kendall's tau=0.30). Though a strong correlation between log intact cell removal and CT was not observed, 16S rRNA gene sequencing results showed that passage through the ozone contactor significantly changed the microbial community (p < 0.05). Potential causes of the low overall cell inactivation in the contactor and the significant changes in the microbial community after ozonation include regrowth in the later chambers of the contactor and varied ozone resistance of drinking water microorganisms. This study demonstrates the suitability of direct, online microbial analysis for monitoring full-scale disinfection systems.
Collapse
Affiliation(s)
- Katherine S Dowdell
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Kirk Olsen
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Ernesto F Martinez Paz
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Aini Sun
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Jeff Keown
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Rebecca Lahr
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Brian Steglitz
- Ann Arbor Water Treatment Plant, City of Ann Arbor, 919 Sunset Rd., Ann Arbor, MI 48103, USA
| | - Andrea Busch
- Great Lakes Water Authority, 9300W. Jefferson Ave, Detroit, MI 48209, USA
| | - John J LiPuma
- Department of Pediatrics, University of Michigan Medical School, 8323 MSRB III, SPC5646, 1150W. Med Cntr Dr., Ann Arbor, MI 48109, USA
| | - Terese Olson
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, 1353 Beal Ave., Ann Arbor, MI 48109, USA.
| |
Collapse
|
4
|
Zarantonello G, Cuenca A. Nanopore-Enabled Microbiome Analysis: Investigating Environmental and Host-Associated Samples in Rainbow Trout Aquaculture. Curr Protoc 2024; 4:e1069. [PMID: 38865207 DOI: 10.1002/cpz1.1069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
Microbiome sequencing is at the forefront of health management development, and as such, it is becoming of great interest to monitor the microbiome in the aquaculture industry as well. Oxford Nanopore Technologies (ONT) platforms are gaining popularity to study microbial communities, enabling faster sequencing, extended read length, and therefore, improved taxonomic resolution. Despite this, there is a lack of clear guidelines to perform a metabarcoding study, especially when dealing with samples from non-mammalian species, such as aquaculture-related samples. In this article, we provide general guidelines for sampling, nucleic acid extraction, and ONT-based library preparation for both environmental (water, sediment) and host-associated (gill or skin mucus, skin, gut content, or gut mucosa) microbiome analysis. Our procedures focus specifically on rainbow trout (Oncorhynchus mykiss) reared in experimental facilities. However, these protocols can also be transferred to alternative types of samples, such as environmental DNA (eDNA) monitoring from alternative water sources, or to different fish species. The additional challenge posed by the low biomass and limited bacterial diversity inherent in fish-associated microbiomes is addressed through the implementation of troubleshooting solutions. Furthermore, we describe a bioinformatic pipeline starting from raw reads and leading to taxonomic abundance tables using currently available tools and software. Finally, we provide a set of specific guidelines and considerations related to the strategic planning of a microbiome study within the context of aquaculture. © 2024 The Authors. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Environmental sample collection Basic Protocol 2: Host-associated sample collection Alternate Protocol: Host-associated sample collection: Alternative sample types Basic Protocol 3: Sample pre-treatment and nucleic acid extraction Basic Protocol 4: Quality control and preparation for 16S rRNA gene sequencing Support Protocol 1: Assessment of inhibition by quantitative PCR Support Protocol 2: Bioinformatic analysis from raw files to taxonomic abundance tables.
Collapse
Affiliation(s)
- Giulia Zarantonello
- National Institute of Aquatic Resources, Technical University of Denmark, Kongens Lyngby, Denmark
| | - Argelia Cuenca
- National Institute of Aquatic Resources, Technical University of Denmark, Kongens Lyngby, Denmark
| |
Collapse
|
5
|
Xin C, Khu ST, Wang T, Zuo X, Zhang Y. Effect of flow fluctuation on water pollution in drinking water distribution systems. ENVIRONMENTAL RESEARCH 2024; 246:118142. [PMID: 38218524 DOI: 10.1016/j.envres.2024.118142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/04/2024] [Accepted: 01/05/2024] [Indexed: 01/15/2024]
Abstract
The detachment of biofilm caused by changes in hydraulic conditions is an essential reason for the pollution of water in the drinking water distribution system (DWDS). In this research, the effect of flow fluctuation on bulk water quality was studied. The turbidity, iron concentration, manganese concentration, the total number of bacteria, biodegradable dissolved organic carbon (BDOC), bacterial community structure, and pathogenic genes in bacteria of bulk water were analyzed. The results indicate that the detachment of biofilm caused by fluctuant flow and reverse flow (especially instant reverse flow) can lead to the pollution of water. Throughout the entire experimental period, the turbidity under fluctuant flow velocity is 4.92%∼49.44% higher than that under other flow velocities. BDOC concentration is 5.68%∼53.99% higher than that under low and high flow velocities. The flow fluctuation increases bacterial regrowth potential (BRP) and reduces the biological stability of the bulk water. Low flow velocity is more conducive to the expression of pathogenic functional genes. In the short term, the water quality under low flow velocity is the best. Nevertheless, in a long-term operation (about seven days later), the water quality under high flow velocity is better than that under other flow velocities. This research brings new knowledge about the fluctuant hydraulic conditions on the bulk water quality within the DWDS and provides data support for stable drinking water distribution.
Collapse
Affiliation(s)
- Changchun Xin
- School of Environmental Science & Engineering, Tianjin University, Tianjin 300350, China
| | - Soon-Thiam Khu
- School of Environmental Science & Engineering, Tianjin University, Tianjin 300350, China; Engineering Research Center of City Intelligence and Digital Governance, Ministry of Education of the People's Republic of China, Tianjin 300350, China
| | - Tianzhi Wang
- School of Environmental Science & Engineering, Tianjin University, Tianjin 300350, China
| | - Xin Zuo
- School of Environmental Science & Engineering, Tianjin University, Tianjin 300350, China
| | - Ying Zhang
- School of Environmental Science & Engineering, Tianjin University, Tianjin 300350, China.
| |
Collapse
|
6
|
Ren A, Yao M, Fang J, Dai Z, Li X, van der Meer W, Medema G, Rose JB, Liu G. Bacterial communities of planktonic bacteria and mature biofilm in service lines and premise plumbing of a Megacity: Composition, Diversity, and influencing factors. ENVIRONMENT INTERNATIONAL 2024; 185:108538. [PMID: 38422875 DOI: 10.1016/j.envint.2024.108538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/14/2024] [Accepted: 02/26/2024] [Indexed: 03/02/2024]
Abstract
Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).
Collapse
Affiliation(s)
- Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| | - Walter van der Meer
- Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands; Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands
| | - Gertjan Medema
- Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
7
|
Kalu CM, Mudau KL, Masindi V, Ijoma GN, Tekere M. Occurrences and implications of pathogenic and antibiotic-resistant bacteria in different stages of drinking water treatment plants and distribution systems. Heliyon 2024; 10:e26380. [PMID: 38434035 PMCID: PMC10906316 DOI: 10.1016/j.heliyon.2024.e26380] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 12/05/2023] [Accepted: 02/12/2024] [Indexed: 03/05/2024] Open
Abstract
Different stages of drinking water treatment plants (DWTPs) play specific roles in diverse contaminants' removal present in natural water sources. Although the stages are recorded to promote adequate treatment of water, the occurrence of pathogenic bacteria (PB) and antibiotic-resistant bacteria (ARB) in the treated water and the changes in their diversity and abundance as it passed down to the end users through the drinking water distribution systems (DWDSs), is a great concern, especially to human health. This could imply that the different stages and the distribution system provide a good microenvironment for their growth. Hence, it becomes pertinent to constantly monitor and document the diversity of PB and ARB present at each stage of the treatment and distribution system. This review aimed at documenting the occurrence of PB and ARB at different stages of treatment and distribution systems as well as the implication of their occurrence globally. An exhaustive literature search from Web of Science, Science-Direct database, Google Scholar, Academic Research Databases like the National Center for Biotechnology Information, Scopus, and SpringerLink was done. The obtained information showed that the different treatment stages and distribution systems influence the PB and ARB that proliferate. To minimize the human health risks associated with the occurrence of these PB, the present review, suggests the development of advanced technologies that can promote quick monitoring of PB/ARB at each treatment stage and distribution system as well as reduction of the cost of environomics analysis to promote better microbial analysis.
Collapse
Affiliation(s)
- Chimdi M. Kalu
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Khuthadzo L. Mudau
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Vhahangwele Masindi
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
- Magalies Water, Scientific Services, Research & Development Division, Brits, South Africa
| | - Grace N. Ijoma
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| | - Memory Tekere
- Department of Environmental Science, College of Agriculture and Environmental Sciences, University of South Africa, Florida, 1710, South Africa
| |
Collapse
|
8
|
Wang L, Chen M, Wu Y, Chen X, Jin H, Huang J. Spatial distribution and vertical characteristics of microplastics in the urban river: The case of Qinhuai River in Nanjing, China. MARINE POLLUTION BULLETIN 2024; 199:115973. [PMID: 38171161 DOI: 10.1016/j.marpolbul.2023.115973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 12/12/2023] [Accepted: 12/21/2023] [Indexed: 01/05/2024]
Abstract
Microplastics (MPs) are emerging as global environmental pollutants, significantly influencing the safety of city rivers. This study investigated six sampling sites in the Qinhuai River of Nanjing, which explored the distribution and characteristics of MPs and the microbial structure in 2023. The studied river contained various levels of MPs with average concentrations of 667.68 items/L, whose abundance firstly decreased midstream and then increased downstream. The MPs abundance upstream was higher in surface water column, microplastics midstream and downstream accumulated more in deep water column. Black and blue are prevalent in the color distribution, while the polymers of PC, PP and PS changed with increasing depth, with a proportion of 74 % ∼ 97 % in the dominant shapes of granules. Furthermore, the water with higher MPs may stimulate the growth of MPs-related bacteria in sediments, including the genus of Pseudoxanthomonas and Dechloromonas. Our research will provide constructive support for enhancing urban river management strategies.
Collapse
Affiliation(s)
- Luming Wang
- Department of Municipal Engineering, School of Civil Engineering, Southeast University, Nanjing 210096, China
| | - Ming Chen
- Nanjing Research Institute of Environmental Protection, Nanjing 210008, China
| | - Yufeng Wu
- Department of Municipal Engineering, School of Civil Engineering, Southeast University, Nanjing 210096, China
| | - Xuan Chen
- Department of Municipal Engineering, School of Civil Engineering, Southeast University, Nanjing 210096, China
| | - Hui Jin
- Nanjing Research Institute of Environmental Protection, Nanjing 210008, China
| | - Juan Huang
- Department of Municipal Engineering, School of Civil Engineering, Southeast University, Nanjing 210096, China.
| |
Collapse
|
9
|
Hawer H, Burmester R, Sonnenberg N, Weiß K. Detection of endotoxins from selected drinking water microbiota using an LAL-based assay and its implications for human health. JOURNAL OF WATER AND HEALTH 2024; 22:290-295. [PMID: 38421623 PMCID: wh_2024_207 DOI: 10.2166/wh.2024.207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Endotoxins are pyrogenic lipopolysaccharides from Gram-negative bacteria that are known to induce fever, septic shock, and multiple organ failure, posing a substantial risk to human health. Drinking water systems are especially prone to home microbiomes containing a large variety of Gram-negative bacteria. Consumption of water from these systems in developed countries is generally regarded as non-hazardous to humans due to the low number of non-pathogenic bacterial cells per milliliter and oral admission. To assess potential risks posed by endotoxins in drinking water systems, we conducted a conventional microbiological investigation on a local community water system in the north of Germany and mined the resulting data to investigate the endotoxin contents of some of the most abundant microbiota found during these analyses. Using a Limulus amoebocyte lysate (LAL) -based endotoxin detection method, average normalized endotoxin content was determined. Although the average culturable amounts of microbiota in the drinking water system were insufficient to exert endotoxin levels critical to human health, peaks and acute contaminations may pose substantial health risks.
Collapse
Affiliation(s)
- Harmen Hawer
- Panpharma GmbH, Bunsenstraße 4, 22946, Trittau, Germany E-mail:
| | | | | | - Katja Weiß
- Panpharma GmbH, Bunsenstraße 4, 22946, Trittau, Germany
| |
Collapse
|
10
|
Lan W, Liu H, Weng R, Zeng Y, Lou J, Xu H, Yu Y, Jiang Y. Microbial community of municipal drinking water in Hangzhou using metagenomic sequencing. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 342:123066. [PMID: 38048871 DOI: 10.1016/j.envpol.2023.123066] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/01/2023] [Accepted: 11/27/2023] [Indexed: 12/06/2023]
Abstract
While traditional culture-dependent methods can effectively detect certain microorganisms, the comprehensive composition of the municipal drinking water (DW) microbiome, including bacteria, archaea, and viruses, remains unknown. Metagenomic sequencing has opened the door to accurately determine and analyze the entire microbial community of DW, providing a comprehensive understanding of DW species diversity, especially in the context of public health concerns during the COVID-19 era. In this study, we found that most of the culturable bacteria and some fecal indicator bacteria, such as Escherichia coli and Pseudomonas aeruginosa, were non-culturable using culture-dependent methods in all samples. However, metagenomic analysis showed that the predominant bacterial species in the DW samples belonged to the phyla Proteobacteria and Planctomycetes. Notably, the genus Methylobacterium was the most abundant in all water samples, followed by Sphingomonas, Gemmata, and Azospirilum. While low levels of virulence-associated factors, such as the Esx-5 type VII secretion system (T7SS) and DevR/S, were detected, only the erythromycin resistance gene erm(X), an rRNA methyltransferase, was identified at low abundance in one sample. Hosts corresponding to virulence and resistance genes were identified in some samples, including Mycobacterium spp. Archaeal DNA (Euryarchaeota, Crenarchaeota) was found in trace amounts in some DW samples. Viruses such as rotavirus, coxsackievirus, human enterovirus, and SARS-CoV-2 were negative in all DW samples using colloidal gold and real-time reverse transcription polymerase chain reaction (RT‒PCR) methods. However, DNA encoding a new order of reverse-transcribing viruses (Ortervirales) and Herpesvirales was found in some DW samples. The metabolic pathways of the entire microbial community involve cell‒cell communication and signal secretion, contributing to cooperation between different microbial populations in the water. This study provides insight into the microbial community and metabolic process of DW in Hangzhou, China, utilizing both culture-dependent methods and metagenomic sequencing combined with bioinformatics tools during the COVID-19 pandemic era.
Collapse
Affiliation(s)
- Wei Lan
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Haiyang Liu
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Rui Weng
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Yaxiong Zeng
- College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 320013, China
| | - Jian Lou
- Yiwu Water Construction Group Co., Ltd., Yiwu, 322000, China
| | - Hongxin Xu
- Yiwu Water Construction Group Co., Ltd., Yiwu, 322000, China
| | - Yunsong Yu
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China
| | - Yan Jiang
- Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China.
| |
Collapse
|
11
|
Zhao B, Liu R, Li Y, Xu H, Li X, Gu J, Zhang X, Wang Y, Wang Y. Changes of putative pathogenic species within the water bacterial community in large-scale drinking water treatment and distribution systems. WATER RESEARCH 2024; 249:120947. [PMID: 38043356 DOI: 10.1016/j.watres.2023.120947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 11/23/2023] [Accepted: 11/29/2023] [Indexed: 12/05/2023]
Abstract
Although the management of microbes in drinking water is of paramount importance for public health, there remain challenges in comprehensively examining pathogenic bacteria in the water supply system at the species level. In this study, high-throughput sequencing of nearly full-length 16S rRNA genes was performed to investigate the changes of the water bacterial community in three large-scale drinking water treatment plants (DWTPs) and their corresponding distribution systems during winter and summer. Our findings revealed significant differences in the bacterial community structure between winter and summer water samples for each DWTP and its distribution management area (DMA). In the groundwater-fed DWTP, selective enrichment of mycobacterial species was observed in both seasons, and the subsequent DMA also exhibited strong selection for specific mycobacterial species. In one of the surface water-fed DWTPs, certain Legionella species present in the source water in winter were selectively enriched in the bacterial community after pre-oxidation, although they were susceptible to the subsequent purification steps. A variety of putative pathogenic species (n = 83) were identified based on our pathogen identification pipeline, with the dominant species representing opportunistic pathogens commonly found in water supply systems. While pathogen removal primarily occurred during the purification processes of DWTPs, especially for surface water-fed plants, the relative abundance of pathogenic bacteria in the DMA water flora was lower than that in the DWTP effluent flora, indicating a diminished competitiveness of pathogens within the DMA ecosystem.
Collapse
Affiliation(s)
- Bei Zhao
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Ruyin Liu
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China; Weiqiao-UCAS Science and Technology Park, Binzhou Institute of Technology, Binzhou, Shandong, PR China.
| | - Yuxian Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Hao Xu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiangyi Li
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Junnong Gu
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Xiaolan Zhang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China; Beijing Engineering Research Center for Drinking Water Quality, Beijing, PR China
| | - Yue Wang
- Beijing Waterworks Group Co., Ltd, Beijing, PR China
| | - Yansong Wang
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, PR China
| |
Collapse
|
12
|
Abkar L, Moghaddam HS, Fowler SJ. Microbial ecology of drinking water from source to tap. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168077. [PMID: 37914126 DOI: 10.1016/j.scitotenv.2023.168077] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 11/03/2023]
Abstract
As drinking water travels from its source, through various treatment processes, hundreds to thousands of kilometres of distribution network pipes, to the taps in private homes and public buildings, it is exposed to numerous environmental changes, as well as other microbes living in both water and on surfaces. This review aims to identify the key locations and factors that are associated with changes in the drinking water microbiome throughout conventional urban drinking water systems from the source to the tap water. Over the past 15 years, improvements in cultivation-independent methods have enabled studies that allow us to answer such questions. As a result, we are beginning to move towards predicting the impacts of disturbances and interventions resulting ultimately in management of drinking water systems and microbial communities rather than mere observation. Many challenges still exist to achieve effective management, particularly within the premise plumbing environment, which exhibits diverse and inconsistent conditions that may lead to alterations in the microbiota, potentially presenting public health risks. Finally, we recommend the establishment of global collaborative projects on the drinking water microbiome that will enhance our current knowledge and lead to tools for operators and researchers alike to improve global access to high-quality drinking water.
Collapse
Affiliation(s)
- Leili Abkar
- Civil Engineering Department, University of British Columbia, Canada.
| | | | - S Jane Fowler
- Department of Biological Sciences, Simon Fraser University, Canada.
| |
Collapse
|
13
|
Çil E. Culturable bacterial flora of juveniles of Pelophylax ridibundus (Pallas, 1771) and influence of abiotic factors on diversity. Folia Microbiol (Praha) 2023; 68:939-949. [PMID: 37233886 DOI: 10.1007/s12223-023-01063-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
This study aims to determine the bacterial flora on the skin surface of the juvenile forms of Pelophylax ridibundus inhabiting three different altitudes and examine potential correlations between bacterial diversity, ecological location, and factors. It was attempted to characterize thirty-two bacteria isolated from the Melet River, Sülük Lake, and Çambaşı Pond through combined biochemical and molecular methods. Canonical correspondence analysis showed that the most important ecological factors for microorganisms to settle on frog skin were determined as water conductivity and dissolved oxygen amount. The most frequently isolated bacteria belonged to the genera Erwinia and Pseudomonas. Altitude positively affected Exiguobacterium. This first report of skin cultivable bacteria from P. ridibundus juvenile forms natural population improves our knowledge of amphibian skin bacterial flora. This study contributes to a better understanding of their ecology and how this species has survived in an environment modulated by altitude.
Collapse
Affiliation(s)
- Elif Çil
- Faculty of Education, Science Education Department, Ordu University, Ordu, Turkey.
| |
Collapse
|
14
|
Zhou Z, Ma W, Li F, Zhong D, Zhang W, Liu L, Zhang J, Zhu Y, Su P. Deciphering the distribution and microbial secretors of extracellular polymeric substances associated antibiotic resistance genes in tube wall biofilm. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 881:163218. [PMID: 37004772 DOI: 10.1016/j.scitotenv.2023.163218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/28/2023] [Accepted: 03/28/2023] [Indexed: 06/01/2023]
Abstract
Antibiotics and disinfectants have both been proposed to exert selective pressures on the biofilm as well as affecting the emergence and spread of antibiotic resistance genes (ARGs). However, the transfer mechanism of ARGs in drinking water distribution system (DWDS) under the coupling effect of antibiotics and disinfectants has not been completely understood. In the current study, four lab-scale biological annular reactors (BARs) were constructed to evaluate the effects of sulfamethoxazole (SMX) and NaClO coupling in DWDS and reveal the related mechanisms of ARGs proliferation. TetM was abundant in both the liquid phase and the biofilm, and redundancy analysis showed that the total organic carbon (TOC) and temperature were significantly correlated with ARGs in the water phase. There was a significant correlation between the relative abundance of ARGs in the biofilm phase and extracellular polymeric substances (EPS). Additionally, the proliferation and spread of ARGs in water phase were related to microbial community structure. Partial least-squares path modeling showed that antibiotic concentration may influence ARGs by affecting MGEs. These findings help us to better understand the diffusion process of ARGs in drinking water and provide a theoretical support for technologies to control ARGs at the front of pipeline.
Collapse
Affiliation(s)
- Ziyi Zhou
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Wencheng Ma
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Feiyu Li
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Dan Zhong
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China.
| | - Wenxuan Zhang
- Guangdong Yuehai Water Investment Co., Ltd., Shenzhen 518000, China
| | - Luming Liu
- Harbin Institute of Technology National Engineering Research Center of Urban Water Resources Co., Ltd., Harbin 150090, China
| | - Jingna Zhang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Yisong Zhu
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin 150090, China
| | - Peng Su
- Changjiang Institute of Survey, Planning, Design and Research, Wuhan 430010, China
| |
Collapse
|
15
|
Sun W, Jing Z. Migration of rare and abundant species, assembly mechanisms, and ecological networks of microbiomes in drinking water treatment plants: Effects of different treatment processes. JOURNAL OF HAZARDOUS MATERIALS 2023; 457:131726. [PMID: 37257378 DOI: 10.1016/j.jhazmat.2023.131726] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 05/23/2023] [Accepted: 05/26/2023] [Indexed: 06/02/2023]
Abstract
Microorganisms play an important role in the degradation of pollutants. However, they also cause problems in drinking water distribution systems, such as pipe corrosion and biofilm growth. The microbial assembly mechanisms and molecular ecological networks associated with different drinking water treatment processes have not yet been clearly analyzed. Therefore, this study investigated the microbiomes of three processes (coal filtration-activated carbon, ozone-activated carbon and UV, and ozone-activated carbon) during different seasons. The results showed that the microbial composition and diversity among the different processes and during different seasons. Water treatment processes had deterministic effects on the microbial assembly process and significantly changed the composition of rare and abundant species, altering the size and modules of molecular ecology networks. Rare species considered as keystone species play important roles in microbial ecology and microbial community construction. Ozone-activated carbon and UV/chlorination decreased the bacterial concentration, increased the deterministic process of microbial assembly, and significantly reduced the size of the network, which is of great significance to microbial control in drinking water. This research broadens our perspectives on the microbial assembly associated with drinking water treatment processes and contributes to ensuring the safe supply of drinking water.
Collapse
Affiliation(s)
- Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| | - Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China; Institute of Environment and Ecology, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen 518055, China.
| |
Collapse
|
16
|
Gao Y, Yang H, Li L, Gao X, Li M, Dong J, Zhang M, Zhang J, Li X, Lu Z, Burford MA. Higher resistance of a microcystin (MC)-producing cyanobacterium, Microcystis, to the submerged macrophyte Myriophyllum spicatum. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:63941-63952. [PMID: 37055695 DOI: 10.1007/s11356-023-26654-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 03/22/2023] [Indexed: 04/15/2023]
Abstract
Outbreaks of Microcystis blooms can affect growth of submerged plants, which in turn can inhibit cyanobacterial growth. Microcystin (MC)-producing and non-MC-producing Microcystis strains typically coexist in Microcystis-dominated blooms. However, the interaction between submerged plants and Microcystis at strain level is not clear. This study was aimed at assessing the effects of a submerged macrophyte Myriophyllum spicatum on one MC-producing versus one non-MC-producing strains of the cyanobacterium Microcystis using plant-Microcystis co-culture experiments. The impacts of Microcystis on M. spicatum were also examined. It showed that the MC-producing Microcystis strain had a higher resistance to negative impacts by the cocultured submerged plant M. spicatum than the non-MC-producing strain. By contrast, the plant M. spicatum was impacted more by the MC-producing Microcystis than the non-MC-producer. The associated bacterioplankton community was affected more by the MC-producing Microcystis than the cocultured M. spicatum. The MC cell quotas were significantly higher in the coculture treatment (the PM + treatment, p < 0.05), indicating that the production and release of MCs might be a key factor responsible for the reduced impact of M. spicatum. The higher concentrations of dissolved organic and reducing inorganic compounds might eventually exacerbate the recovering capacity of coexisting submerged plants. Overall, this study indicated that the capacity to produce MCs, as well as the density of Microcystis, should be taken into account when attempting to reestablish submerged vegetation to undertake remediation works.
Collapse
Affiliation(s)
- Yunni Gao
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Hui Yang
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
| | - Longfei Li
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
| | - Xiaofei Gao
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Mei Li
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Jing Dong
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Man Zhang
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Jingxiao Zhang
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China
| | - Xuejun Li
- Engineering Lab of Henan Province for Aquatic Animal Disease Control, Engineering Technology Research Center of Henan Province for Aquatic Animal Cultivation, College of Fisheries, Henan Normal University, Xinxiang, 453007, China.
- Observation and Research Station On Water Ecosystem in Danjiangkou Reservoir of Henan Province, Nanyang, 474450, China.
| | - Zhiying Lu
- Department of Biology, University of Alabama at Birmingham, Birmingham, AL, 35233, USA
| | - Michele A Burford
- Australian Rivers Institute, Griffith University, 170 Kessels Road, Nathan, QLD, 4111, Australia
| |
Collapse
|
17
|
Community Composition and Antibiotic Resistance of Tap Water Bacteria Retained on Filtration Membranes. DIVERSITY 2023. [DOI: 10.3390/d15030427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
Community composition and antibiotic resistance of tap water bacteria are still not known well enough. This study fills the gaps in knowledge regarding this matter. To provide representativeness of collected samples, tap water bacteria were concentrated from huge amounts of water, using filtration membranes monthly during the continuous, semi-annual study, covering winter and spring seasons. Biomass was investigated both using a culture-based method (for total and antibiotic-resistant culturable bacteria counts) and metagenomic DNA sequencing (for taxonomic identification of bacteria). The results showed that bacteria resistant to ceftazidime were the most prevalent among the studied resistance phenotypes, whereas bacteria resistant to amoxicillin, ciprofloxacin, and tetracycline were scarce. On average, 20,059 and 26,200 CFU/mL per month was counted in the winter and spring season, respectively, whereas in terms of antibiotic-resistant bacteria, average counts were 14,270 and 9435 CFU/mL per month in the winter and spring season, respectively. In terms of bacterial community composition, Cyanobacteria, Proteobacteria and Actinobacteria were the most abundant phyla, reaching up to 77.71%, 74.40% and 21.85%, respectively, which is supported by previous studies conducted on the same water supply network and other drinking water distribution systems across the world. No season-dependent variations were observed for culturable antibiotic-resistant bacteria or bacterial community composition. The prevalence of culturable antibiotic-resistant bacteria was not correlated with any of the identified taxa.
Collapse
|
18
|
Hu D, Zeng J, Chen J, Lin W, Xiao X, Feng M, Yu X. Microbiological quality of roof tank water in an urban village in southeastern China. J Environ Sci (China) 2023; 125:148-159. [PMID: 36375901 DOI: 10.1016/j.jes.2022.01.036] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 01/18/2022] [Accepted: 01/24/2022] [Indexed: 06/16/2023]
Abstract
Urban villages are unique residential neighborhoods in urban areas in China. Roof tanks are their main form of water supply, and water quality deterioration might occur in this system because of poor hygienic conditions and maintenance. In this study, water samples were seasonally collected from an urban village to investigate the influence of roof tanks as an additional water storage device on the variation in the microbial community structure and pathogenic gene markers. Water stagnation in the roof tank induced significant decreases in chlorine (p < 0.05), residual chlorine was as low as 0.02 mg/L in spring. Propidium monoazide (PMA)-qPCR revealed a one-magnitude higher level of total viable bacterial concentration in roof tank water samples (2.14 ± 1.81 × 105 gene copies/mL) than that in input water samples (3.57 ± 2.90 × 104 gene copies/mL, p < 0.05), especially in spring and summer. In addition, pathogenic fungi, Mycobacterium spp., and Legionella spp. were frequently detected in the roof tanks. Terminal users might be exposed to higher microbial risk induced by high abundance of Legionella gene marker. Spearman's rank correlation and redundancy analysis showed that residual chlorine was the driving force that promoted bacterial colonization and shaped the microbial community. It is worth noted that the sediment in the pipe will be agitated when the water supply is restored after the water outages, which can trigger an increase in turbidity and bacterial biomass. Overall, the findings provide practical suggestions for controlling microbiological health risks in roof tanks in urban villages.
Collapse
Affiliation(s)
- Dong Hu
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jie Zeng
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Jing Chen
- Shitang Community Health Service Center, Xiamen 361026, China
| | - Wenfang Lin
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Xinyan Xiao
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Mingbao Feng
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China
| | - Xin Yu
- College of the Environment and Ecology, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
19
|
Foote A, Schutz K, Zhao Z, DiGianivittorio P, Korwin-Mihavics BR, LiPuma JJ, Wargo MJ. Characterizing Biofilm Interactions between Ralstonia insidiosa and Chryseobacterium gleum. Microbiol Spectr 2023; 11:e0410522. [PMID: 36744887 PMCID: PMC10100896 DOI: 10.1128/spectrum.04105-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 01/11/2023] [Indexed: 02/07/2023] Open
Abstract
Ralstonia insidiosa and Chryseobacterium gleum are bacterial species commonly found in potable water systems, and these two species contribute to the robustness of biofilm formation in a model six-species community from the International Space Station (ISS) potable water system. Here, we set about characterizing the interaction between these two ISS-derived strains and examining the extent to which this interaction extends to other strains and species in these two genera. The enhanced biofilm formation between the ISS strains of R. insidiosa and C. gleum is robust to starting inoculum and temperature and occurs in some but not all tested growth media, and evidence does not support a soluble mediator or coaggregation mechanism. These findings shed light on the ISS R. insidiosa and C. gleum interaction, though such enhancement is not common between these species based on our examination of other R. insidiosa and C. gleum strains, as well as other species of Ralstonia and Chryseobacterium. Thus, while the findings presented here increase our understanding of the ISS potable water model system, not all our findings are broadly extrapolatable to strains found outside of the ISS. IMPORTANCE Biofilms present in drinking water systems and terminal fixtures are important for human health, pipe corrosion, and water taste. Here, we examine the enhanced biofilm of cocultures for two very common bacteria from potable water systems: Ralstonia insidiosa and Chryseobacterium gleum. While strains originally isolated on the International Space Station show enhanced dual-species biofilm formation, terrestrial strains do not show the same interaction properties. This study contributes to our understanding of these two species in both dual-culture and monoculture biofilm formation.
Collapse
Affiliation(s)
- Andrea Foote
- Cellular, Molecular, and Biomedical Sciences Graduate Program, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
| | - Kristin Schutz
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
| | - Zirui Zhao
- Department of Biology, University of Vermont, Burlington, Vermont, USA
| | - Pauline DiGianivittorio
- Cellular, Molecular, and Biomedical Sciences Graduate Program, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
| | - Bethany R. Korwin-Mihavics
- Cellular, Molecular, and Biomedical Sciences Graduate Program, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
| | - John J. LiPuma
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, Michigan, USA
| | - Matthew J. Wargo
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicine, Burlington, Vermont, USA
| |
Collapse
|
20
|
Jing Z, Lu Z, Zhao Z, Cao W, Wang W, Ke Y, Wang X, Sun W. Molecular ecological networks reveal the spatial-temporal variation of microbial communities in drinking water distribution systems. J Environ Sci (China) 2023; 124:176-186. [PMID: 36182128 DOI: 10.1016/j.jes.2021.10.017] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 10/12/2021] [Accepted: 10/12/2021] [Indexed: 06/16/2023]
Abstract
Microbial activity and regrowth in drinking water distribution systems is a major concern for water service companies. However, previous studies have focused on the microbial composition and diversity of the drinking water distribution systems (DWDSs), with little discussion on microbial molecular ecological networks (MENs) in different water supply networks. MEN analysis explores the potential microbial interaction and the impact of environmental stress, to explain the characteristics of microbial community structures. In this study, the random matrix theory-based network analysis was employed to investigate the impact of seasonal variation including water source switching on the networks of three DWDSs that used different disinfection methods. The results showed that microbial interaction varied slightly with the seasons but was significantly influenced by different DWDSs. Proteobacteria, identified as key species, play an important role in the network. Combined UV-chlorine disinfection can effectively reduce the size and complexity of the network compared to chlorine disinfection alone, ignoring seasonal variations, which may affect microbial activity or control microbial regrowth in DWDSs. This study provides new insights for analyzing the dynamics of microbial interactions in DWDSs.
Collapse
Affiliation(s)
- Zibo Jing
- Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China; School of Environment, Tsinghua University, Beijing 100084, China
| | - Zedong Lu
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Zhinan Zhao
- Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Wenfeng Cao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Weibo Wang
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Yanchu Ke
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Xiaohui Wang
- Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| |
Collapse
|
21
|
Koizumi Y, Ichijo T, Uchii K, Nasu M. Changes in bacterial diversity and community structure in drinking water distribution system revealed by high throughput sequencing. JOURNAL OF MICROORGANISM CONTROL 2023; 28:27-34. [PMID: 37277955 DOI: 10.4265/jmc.28.1_27] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
For microbiological management of water quality, it is important to identify bacteria and to understand the community structure. To analyze the community structure during water purification and distribution, we selected a distribution system in which water from other water treatment facilities was not mixed with the target water. Changes in the bacterial community structure during treatment and distribution processes in a slow filtration water treatment facility were analyzed using 16S rRNA gene amplicon sequencing with a portable sequencer MinION. The microbial diversity was reduced by chlorination. The genus level diversity increased during distribution and this diversity was maintained through to the terminal tap water. Yersinia and Aeromonas were dominant in the intake water, and Legionella was dominant in the slow sand filtered water. Chlorination greatly reduced the relative abundance of Yersinia, Aeromonas, and Legionella, and these bacteria were not detected in the terminal tap water. Sphingomonas, Starkeya and Methylobacterium became dominant in the water after chlorination. These bacteria could be used as important indicator bacteria to provide useful information for microbiological control in drinking water distribution systems.
Collapse
Affiliation(s)
- Yoshihiko Koizumi
- Environmental Health Section, Osaka Institute of Public Health
- Graduate School of Pharmaceutical Sciences, Osaka Ohtani University
| | - Tomoaki Ichijo
- Faculty of Health and Nutrition, Osaka Shoin Women's University
- Graduate School of Human Sciences, Osaka Shoin Women's University
| | | | - Masao Nasu
- Graduate School of Pharmaceutical Sciences, Osaka Ohtani University
- Osaka University
| |
Collapse
|
22
|
Entezari S, Al MA, Mostashari A, Ganjidoust H, Ayati B, Yang J. Microplastics in urban waters and its effects on microbial communities: a critical review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:88410-88431. [PMID: 36327084 DOI: 10.1007/s11356-022-23810-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 10/20/2022] [Indexed: 06/16/2023]
Abstract
Microplastic (MP) pollution is one of the emerging threats to the water and terrestrial environment, forcing a new environmental challenge due to the growing trend of plastic released into the environment. Synthetic and non-synthetic plastic components can be found in rivers, lakes/reservoirs, oceans, mountains, and even remote areas, such as the Arctic and Antarctic ice sheets. MPs' main challenge is identifying, measuring, and evaluating their impacts on environmental behaviors, such as carbon and nutrient cycles, water and wastewater microbiome, and the associated side effects. However, until now, no standardized methodical protocols have been proposed for comparing the results of studies in different environments, especially in urban water and wastewater. This review briefly discusses MPs' sources, fate, and transport in urban waters and explains methodological uncertainty. The effects of MPs on urban water microbiomes, including urban runoff, sewage wastewater, stagnant water in plumbing networks, etc., are also examined in depth. Furthermore, this study highlights the pathway of MPs and their transport vectors to different parts of ecosystems and human life, particularly through mediating microbial communities, antibiotic-resistant genes, and biogeochemical cycles. Overall, we have briefly highlighted the present research gaps, the lack of appropriate policy for evaluating microplastics and their interactions with urban water microbiomes, and possible future initiatives.
Collapse
Affiliation(s)
- Saber Entezari
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Mamun Abdullah Al
- Aquatic Eco-Health Group, Fujian Key Laboratory of Watershed Ecology, Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Amir Mostashari
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Hossein Ganjidoust
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran.
| | - Bita Ayati
- Environmental Engineering Division, Faculty of Civil & Env. Eng., TMU, Tehran, Iran
| | - Jun Yang
- Aquatic Eco-Health Group, Fujian Key Laboratory of Watershed Ecology, Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
| |
Collapse
|
23
|
Zhang H, Liu X, Huang T, Ma B, Sun W, Zhao K, Sekar R, Xing Y. Stagnation trigger changes to tap water quality in winter season: Novel insights into bacterial community activity and composition. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 844:157240. [PMID: 35817116 DOI: 10.1016/j.scitotenv.2022.157240] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/02/2022] [Accepted: 07/04/2022] [Indexed: 06/15/2023]
Abstract
The drinking water distribution system is important for water supply and it affects the quality of the drinking water. Indoor pipeline water quality is regulated by physical, hydraulic and biological elements, such as indoor temperature and stagnation. In this work, the effects of indoor heating and overnight stagnation on the variation in bacterial community structure and the total cell count were assessed by full-length 16S rRNA gene sequencing and flow cytometry, respectively. The results exhibited that the average intact cell count was 6.99 × 104 cells/mL and the low nucleic acid (LNA) bacteria was 4.48 × 104 cells/mL after stagnation. The average concentration of total and intracellular adenosine triphosphate (ATP) was 3.64 × 10-12 gATP/mL and 3.13 × 10-17 gATP/cell in stagnant water, respectively. The growth of LNA cells played a crucial role in increasing ATP. The dominant phylum observed was Proteobacteria (87.21 %), followed by Actinobacteria (8.25 %). Opportunistic pathogens increased the risk of disease in stagnant water (up to 1.2-fold for Pseudomonas sp. and 5.8-fold for Mycobacterium sp.). Meanwhile, structural equation model (SEM) and redundancy analysis (RDA) also illustrated that water temperature, residual chlorine and Fe significantly affected the abundance and composition of bacterial community. Taking together, these results show response of tap water quality to overnight stagnation and indoor heating, and provide scientific basis for drinking water security management in winter season.
Collapse
Affiliation(s)
- Haihan Zhang
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China.
| | - Xiang Liu
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Tinglin Huang
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Ben Ma
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Weimin Sun
- National-Regional Joint Engineering Research Center for Soil Pollution Control and Remediation in South China, Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Institute of Eco-environmental and Soil Sciences, Guangdong Academy of Sciences, Guangzhou, China; Guangdong-Hong Kong-Macao Joint Laboratory for Environmental Pollution and Control, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Kexin Zhao
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, China
| | - Raju Sekar
- Department of Biological Sciences, Xi'an Jiaotong-Liverpool University, Suzhou, China
| | - Yan Xing
- Shaanxi Environmental Monitoring Center, Xi'an, China
| |
Collapse
|
24
|
Bjørklund G, Shanaida M, Lysiuk R, Butnariu M, Peana M, Sarac I, Strus O, Smetanina K, Chirumbolo S. Natural Compounds and Products from an Anti-Aging Perspective. Molecules 2022; 27:7084. [PMID: 36296673 PMCID: PMC9610014 DOI: 10.3390/molecules27207084] [Citation(s) in RCA: 54] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/11/2022] [Accepted: 10/14/2022] [Indexed: 11/17/2022] Open
Abstract
Aging is a very complex process that is accompanied by a degenerative impairment in many of the major functions of the human body over time. This inevitable process is influenced by hereditary factors, lifestyle, and environmental influences such as xenobiotic pollution, infectious agents, UV radiation, diet-borne toxins, and so on. Many external and internal signs and symptoms are related with the aging process and senescence, including skin dryness and wrinkles, atherosclerosis, diabetes, neurodegenerative disorders, cancer, etc. Oxidative stress, a consequence of the imbalance between pro- and antioxidants, is one of the main provoking factors causing aging-related damages and concerns, due to the generation of highly reactive byproducts such as reactive oxygen and nitrogen species during the metabolism, which result in cellular damage and apoptosis. Antioxidants can prevent these processes and extend healthy longevity due to the ability to inhibit the formation of free radicals or interrupt their propagation, thereby lowering the level of oxidative stress. This review focuses on supporting the antioxidant system of the organism by balancing the diet through the consumption of the necessary amount of natural ingredients, including vitamins, minerals, polyunsaturated fatty acids (PUFA), essential amino acids, probiotics, plants' fibers, nutritional supplements, polyphenols, some phytoextracts, and drinking water.
Collapse
Affiliation(s)
- Geir Bjørklund
- Council for Nutritional and Environmental Medicine (CONEM), Toften 24, 8610 Mo i Rana, Norway
| | - Mariia Shanaida
- Department of Pharmacognosy and Medical Botany, I. Horbachevsky Ternopil National Medical University, 46001 Ternopil, Ukraine
| | - Roman Lysiuk
- Department of Pharmacognosy and Botany, Danylo Halytsky Lviv National Medical University, 79010 Lviv, Ukraine
- CONEM Ukraine Life Science Research Group, Danylo Halytsky Lviv National Medical University, 79010 Lviv, Ukraine
| | - Monica Butnariu
- Chemistry & Biochemistry Discipline, Banat’s University of Agricultural Sciences and Veterinary Medicine “King Michael I of Romania” from Timisoara, 300645 Timisoara, Romania
- CONEM Romania Biotechnology and Environmental Sciences Group, University of Life Sciences “King Mihai I” from Timisoara, 300645 Timisoara, Romania
| | - Massimiliano Peana
- Department of Chemical, Physical, Mathematical and Natural Sciences, University of Sassari, 07100 Sassari, Italy
| | - Ioan Sarac
- Chemistry & Biochemistry Discipline, Banat’s University of Agricultural Sciences and Veterinary Medicine “King Michael I of Romania” from Timisoara, 300645 Timisoara, Romania
- CONEM Romania Biotechnology and Environmental Sciences Group, University of Life Sciences “King Mihai I” from Timisoara, 300645 Timisoara, Romania
| | - Oksana Strus
- Department of Drug Technology and Biopharmaceutics, Danylo Halytsky Lviv National Medical University, 79010 Lviv, Ukraine
| | - Kateryna Smetanina
- Department of Organic Chemistry and Pharmacy, Lesya Ukrainka Volyn National University, 43025 Lutsk, Ukraine
| | - Salvatore Chirumbolo
- Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, 37134 Verona, Italy
- CONEM Scientific Secretary, Strada Le Grazie 9, 37134 Verona, Italy
| |
Collapse
|
25
|
Su Z, Liu T, Men Y, Li S, Graham N, Yu W. Understanding point-of-use tap water quality: From instrument measurement to intelligent analysis using sample filtration. WATER RESEARCH 2022; 225:119205. [PMID: 36215843 DOI: 10.1016/j.watres.2022.119205] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 09/19/2022] [Accepted: 10/03/2022] [Indexed: 06/16/2023]
Abstract
In most cases, point-of-use tap water quality is not routinely monitored due to widely-dispersed sampling sites and the costly tests. Although previous studies have revealed the variation of drinking water quality during distribution in municipal networks, the influence of aging pipes in buildings on quality is still unknown and this makes it difficult for water utilities to conduct regular maintenance. Herein, we have undertaken a survey of tap water samples across 8 districts in Beijing (China) to evaluate the potential effects of pipe age on point-of-use water quality, including turbidity, organic matter characteristics, and bacterial community. By grouping the collected samples according to the pipe age and source water respectively, the results suggested that bacterial diversity is significantly influenced by the pipe age. However, bacterial community structure is clearly influenced by the source water. Similarly, aging pipes in buildings are also responsible for the deterioration of the final water quality, and their effects have been closely linked to selected water quality parameters by evaluating the relevant factors. Moreover, the interrelationships between physico-chemical parameters and bacteria abundance were identified. For example, pH, Ca2+, Mg2+, Na+ and K+ showed a positive relationship with Bacillus abundance. In addition, an intelligent analysis method for understanding pipe age, organic matter concentration, and hardness (i.e., Ca2+ and Mg2+ concentration), based on image analysis of filtered membranes has been developed. The accuracy of prediction was encouraging, but can be improved with the collection of more data from tap water samples. We expect that this method can be exploited by the public to monitor their tap water and provide a feasible and cost-effective approach for water suppliers to locate aging/deteriorating pipes which need to be replaced or maintained.
Collapse
Affiliation(s)
- Zhaoyang Su
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Ting Liu
- School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Yujie Men
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA 92521, United States
| | - Shuo Li
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Nigel Graham
- Department of Civil and Environmental Engineering, Imperial College London, South Kensington Campus, London SW7 2AZ, UK
| | - Wenzheng Yu
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| |
Collapse
|
26
|
Xu MY, Lin YL, Zhang TY, Hu CY, Tang YL, Deng J, Xu B. Chlorine dioxide-based oxidation processes for water purification:A review. JOURNAL OF HAZARDOUS MATERIALS 2022; 436:129195. [PMID: 35739725 DOI: 10.1016/j.jhazmat.2022.129195] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 05/14/2022] [Accepted: 05/18/2022] [Indexed: 06/15/2023]
Abstract
Chlorine dioxide (ClO2) has emerged as a broad-spectrum, safe, and effective disinfectant due to its high oxidation efficiency and reduced formation of organochlorinated by-products during application. This article provides an updated overview of ClO2-based oxidation processes used in water treatment. A systematic review of scientific information and experimental data on ClO2-based water purification procedures is presented. Concerning ClO2-based oxidation derivative problems, the pros and cons of ClO2-based combined processes are assessed and disinfection by-product (DBP) control approaches are proposed. The kinetic and mechanistic data on ClO2 reactivity towards micropollutants are discussed. ClO2 selectively reacts with electron-rich moieties (anilines, phenols, olefins, and amines) and eliminates certain inorganic ions and microorganisms with high efficiency. The formation of chlorite and chlorate during the oxidation process is a crucial concern when utilizing ClO2. Future applications include the combination of ClO2 with ferrous ions, activated carbon, ozone, UV, visible light, or persulfate processes. The combined process can reduce by-product generation while still ensuring ClO2 sterilization and disinfection. Overall, this research could provide useful information and new insights into the application of ClO2-based technologies.
Collapse
Affiliation(s)
- Meng-Yuan Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Yi-Li Lin
- Department of Safety, Health and Environmental Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 824, Taiwan, ROC
| | - Tian-Yang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Chen-Yan Hu
- College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, PR China
| | - Yu-Lin Tang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jing Deng
- College of Civil Engineering, Zhejiang University of Technology, Hangzhou 310023, PR China
| | - Bin Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
27
|
Bruno A, Agostinetto G, Fumagalli S, Ghisleni G, Sandionigi A. It’s a Long Way to the Tap: Microbiome and DNA-Based Omics at the Core of Drinking Water Quality. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19137940. [PMID: 35805598 PMCID: PMC9266242 DOI: 10.3390/ijerph19137940] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 06/17/2022] [Accepted: 06/24/2022] [Indexed: 11/16/2022]
Abstract
Microbial communities interact with us and affect our health in ways that are only beginning to be understood. Microorganisms have been detected in every ecosystem on Earth, as well as in any built environment that has been investigated. Drinking water sources, drinking water treatment plants and distribution systems provide peculiar microbial ecological niches, dismantling the belief of the “biological simplicity” of drinking water. Nevertheless, drinking water microbiomes are understudied compared to other microbiomes. Recent DNA sequencing and meta-omics advancements allow a deeper understanding of drinking water microbiota. Thus, moving beyond the limits of day-to-day testing for specific pathogenic microbes, new approaches aim at predicting microbiome changes driven by disturbances at the macro-scale and overtime. This will foster an effective and proactive management of water sources, improving the drinking water supply system and the monitoring activities to lower public health risk. Here, we want to give a new angle on drinking water microbiome research. Starting from a selection of 231 scientific publications on this topic, we emphasize the value of biodiversity in drinking water ecosystems and how it can be related with industrialization. We then discuss how microbiome research can support sustainable drinking water management, encouraging collaborations across sectors and involving the society through responsible research and innovation.
Collapse
Affiliation(s)
- Antonia Bruno
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
- Correspondence:
| | - Giulia Agostinetto
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
| | - Sara Fumagalli
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
| | - Giulia Ghisleni
- Biotechnology and Biosciences Department, University of Milano-Bicocca, 20126 Milan, Italy; (G.A.); (S.F.); (G.G.)
- Institut Jacques Monod, Université Paris Cité, CNRS, 75013 Paris, France
| | | |
Collapse
|
28
|
Mahajna A, Dinkla IJT, Euverink GJW, Keesman KJ, Jayawardhana B. Clean and Safe Drinking Water Systems via Metagenomics Data and Artificial Intelligence: State-of-the-Art and Future Perspective. Front Microbiol 2022; 13:832452. [PMID: 35602066 PMCID: PMC9121918 DOI: 10.3389/fmicb.2022.832452] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 04/04/2022] [Indexed: 12/01/2022] Open
Abstract
The use of next-generation sequencing technologies in drinking water distribution systems (DWDS) has shed insight into the microbial communities' composition, and interaction in the drinking water microbiome. For the past two decades, various studies have been conducted in which metagenomics data have been collected over extended periods and analyzed spatially and temporally to understand the dynamics of microbial communities in DWDS. In this literature review, we outline the findings which were reported in the literature on what kind of occupancy-abundance patterns are exhibited in the drinking water microbiome, how the drinking water microbiome dynamically evolves spatially and temporally in the distribution networks, how different microbial communities co-exist, and what kind of clusters exist in the drinking water ecosystem. While data analysis in the current literature concerns mainly with confirmatory and exploratory questions pertaining to the use of metagenomics data for the analysis of DWDS microbiome, we present also future perspectives and the potential role of artificial intelligence (AI) and mechanistic models to address the predictive and mechanistic questions. The integration of meta-omics, AI, and mechanistic models transcends metagenomics into functional metagenomics, enabling deterministic understanding and control of DWDS for clean and safe drinking water systems of the future.
Collapse
Affiliation(s)
- Asala Mahajna
- Wetsus – European Centre of Excellence for Sustainable Water Technology, Leeuwarden, Netherlands
- Engineering and Technology Institute Groningen, University of Groningen, Groningen, Netherlands
| | - Inez J. T. Dinkla
- Wetsus – European Centre of Excellence for Sustainable Water Technology, Leeuwarden, Netherlands
| | - Gert Jan W. Euverink
- Engineering and Technology Institute Groningen, University of Groningen, Groningen, Netherlands
| | - Karel J. Keesman
- Mathematical and Statistical Methods – Biometris, Wageningen University, Wageningen, Netherlands
| | - Bayu Jayawardhana
- Engineering and Technology Institute Groningen, University of Groningen, Groningen, Netherlands
| |
Collapse
|
29
|
Lu Z, Jing Z, Huang J, Ke Y, Li C, Zhao Z, Ao X, Sun W. Can we shape microbial communities to enhance biological activated carbon filter performance? WATER RESEARCH 2022; 212:118104. [PMID: 35114529 DOI: 10.1016/j.watres.2022.118104] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 01/16/2022] [Accepted: 01/17/2022] [Indexed: 06/14/2023]
Abstract
A new focus on biofiltration has emerged that aims to shape microbial communities to improve treatment efficacy. It is therefore necessary to understand the linkages between microbial community structure and biofilter function. However, the assembly and interaction of microbial communities in biological activated carbon (BAC) filters are unknown. In this study, we selected one coal-based granular activated carbon (GAC), GAC-13, with simultaneously developed micropore and micro-level macropore volume used for a bench-scale BAC column experiment, and compared it with other coal-based GACs and wood-based GAC in terms of the dissolved organic carbon (DOC) removal and microbial community characteristics. The results showed that there was no difference between the DOC removal efficiency of BAC-13 and the other two coal-based BAC filters with high iodine value in the period dominated by adsorption, while the DOC removal efficiency of BAC-13 (64.7±0.6%) was significantly higher than that of other BAC filters (36.3±0.8-54.1±0.4%) with a difference of 0.3-0.7 mg/L in DOC during the steady state. The bacterial communities were strongly assembled by deterministic rather than stochastic factors, where the surface polarity of GAC had a greater effect on the microbial communities than its physical properties. The corresponding co-occurrence network revealed that microbes in the BAC filter may be more cooperative than competitive. The keystone bacterium Hyphomicrobium, which had a relatively low abundance, contributed 0.3-1% more to the most abundant functions and produced 5-21 proteins/(g·GAC) more than the dominant bacterium Sphingobium. The metaproteomic-based approach could provide more accurate information regarding the contributions of different species to metabolic functions. The pore size distribution of GAC was found to be an important factor in determining BAC filter performance; the most important pore sizes were micropores and micro-level macropores (0.2-10 μm and >100 μm in diameter), and the latter impacted the abundance of keystone species. Overall, our findings provide new insights into shaping microbial communities by optimizing pore size structure to improve BAC performance, especially the abundance of keystone species.
Collapse
Affiliation(s)
- Zedong Lu
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China
| | - Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China; Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Jing Huang
- Beijing Drainage Group Co. Ltd. (BDG), Beijing 100022, China
| | - Yanchu Ke
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Chen Li
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Zhinan Zhao
- School of Environment, Tsinghua University, Beijing 100084, China; Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xiuwei Ao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| |
Collapse
|
30
|
Rahmatika I, Kurisu F, Furumai H, Kasuga I. Dynamics of the Microbial Community and Opportunistic Pathogens after Water Stagnation in the Premise Plumbing of a Building. Microbes Environ 2022; 37. [PMID: 35321996 PMCID: PMC8958293 DOI: 10.1264/jsme2.me21065] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
In premise plumbing, microbial water quality may deteriorate under certain conditions, such as stagnation. Stagnation results in a loss of disinfectant residual, which may lead to the regrowth of microorganisms, including opportunistic pathogens. In the present study, microbial regrowth was investigated at eight faucets in a building over four seasons in one year. Water samples were obtained before and after 24 h of stagnation. In the first 100 mL after stagnation, total cell counts measured by flow cytometry increased 14- to 220-fold with a simultaneous decrease in free chlorine from 0.17–0.36 mg L–1 to <0.02 mg L–1. After stagnation, total cell counts were not significantly different among seasons; however, the composition of the microbial community varied seasonally. The relative abundance of Pseudomonas spp. was dominant in winter, whereas Sphingomonas spp. were dominant in most faucets after stagnation in other seasons. Opportunistic pathogens, such as Legionella pneumophila, Mycobacterium avium, Pseudomonas aeruginosa, and Acanthamoeba spp., were below the quantification limit for real-time quantitative PCR in all samples. However, sequences related to other opportunistic pathogens, including L. feeleii, L. maceachernii, L. micdadei, M. paragordonae, M. gordonae, and M. haemophilum, were detected. These results indicate that health risks may increase after stagnation due to the regrowth of opportunistic pathogens.
Collapse
Affiliation(s)
- Iftita Rahmatika
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| | - Futoshi Kurisu
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, Graduate School of Engineering, The University of Tokyo
| | - Ikuro Kasuga
- Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo
| |
Collapse
|
31
|
Variation in the Structure and Composition of Bacterial Communities within Drinking Water Fountains in Melbourne, Australia. WATER 2022. [DOI: 10.3390/w14060908] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Modern drinking water distributions systems (DWDSs) have been designed to transport treated or untreated water safely to the consumer. DWDSs are complex environments where microorganisms are able to create their own niches within water, biofilm or sediment. This study was conducted on twelve drinking fountains (of three different types, namely types A, B and C) within the Melbourne (Australia) city area with the aim to (i) characterize the water quality and viable and total counts at each fountain, (ii) compare the differences in the structure and diversity of the bacterial community between bulk water and biofilm and (iii) determine differences between the bacterial communities based on fountain type. Samples of water and biofilm were assessed using both culture-dependent and culture-independent techniques. Heterotrophic plate counts of water samples ranged from 0.5 to 107.5 CFU mL−1, and as expected, total cell counts (cells mL−1) were, on average, 2.9 orders of magnitude higher. Based on the mean relative abundance of operational taxonomic units (OTUs), ANOSIM showed that the structure of the bacterial communities in drinking water and biofilm varied significantly (R = 0.58, p = 0.001). Additionally, ANOSIM showed that across fountain types (in water), the bacterial community was more diverse in fountain type C compared to type A (p < 0.001) and type B (p < 0.001). 16S rRNA next-generation sequencing revealed that the bacterial communities in both water and biofilm were dominated by only seven phyla, with Proteobacteria accounting for 71.3% of reads in water and 68.9% in biofilm. The next most abundant phylum was Actinobacteria (10.4% water; 11.7% biofilm). In water, the genus with the highest overall mean relative abundance was Sphingomonas (24.2%), while Methylobacterium had the highest mean relative abundance in biofilm samples (54.7%). At the level of genus and higher, significant differences in dominance were found across fountain types. In water, Solirubrobacterales (order) were present in type C fountains at a relative abundance of 17%, while the mean relative abundance of Sphingomonas sp. in type C fountains was less than half that in types A (25%) and B (43%). In biofilm, the relative abundance of Sphingomonas sp. was more than double in type A (10%) fountains compared to types B (4%) and C (5%), and Sandarakinorhabdus sp. were high in type A fountains (6%) and low in types B and C (1%). Overall this research showed that there were significant differences in the composition of bacterial communities in water and biofilm from the same site. Furthermore, significant variation exists between microbial communities present in the fountain types, which may be related to age. Long-established environments may lead to a greater chance of certain bacteria gaining abilities such as increased disinfection resistance. Variations between the structure of the bacterial community residing in water and biofilm and differences between fountain types show that it is essential to regularly test samples from individual locations to determine microbial quality.
Collapse
|
32
|
Lee D, Calendo G, Kopec K, Henry R, Coutts S, McCarthy D, Murphy HM. The Impact of Pipe Material on the Diversity of Microbial Communities in Drinking Water Distribution Systems. Front Microbiol 2021; 12:779016. [PMID: 34992587 PMCID: PMC8724538 DOI: 10.3389/fmicb.2021.779016] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 12/01/2021] [Indexed: 01/04/2023] Open
Abstract
As many cities around the world face the prospect of replacing aging drinking water distribution systems (DWDS), water utilities must make careful decisions on new pipe material (e.g., cement-lined or PVC) for these systems. These decisions are informed by cost, physical integrity, and impact on microbiological and physicochemical water quality. Indeed, pipe material can impact the development of biofilm in DWDS that can harbor pathogens and impact drinking water quality. Annular reactors (ARs) with cast iron and cement coupons fed with chloraminated water from a municipal DWDS were used to investigate the impact of pipe material on biofilm development and composition over 16 months. The ARs were plumbed as closely as possible to the water main in the basement of an academic building to simulate distribution system conditions. Biofilm communities on coupons were characterized using 16S rRNA sequencing. In the cast iron reactors, β-proteobacteria, Actinobacteria, and α-proteobacteria were similarly relatively abundant (24.1, 22.5, and 22.4%, respectively) while in the cement reactors, α-proteobacteria and Actinobacteria were more relatively abundant (36.3 and 35.2%, respectively) compared to β-proteobacteria (12.8%). Mean alpha diversity (estimated with Shannon H and Faith's Phylogenetic Difference indices) was greater in cast iron reactors (Shannon: 5.00 ± 0.41; Faith's PD: 15.40 ± 2.88) than in cement reactors (Shannon: 4.16 ± 0.78; Faith's PD: 13.00 ± 2.01). PCoA of Bray-Curtis dissimilarities indicated that communities in cast iron ARs, cement ARs, bulk distribution system water, and distribution system pipe biofilm were distinct. The mean relative abundance of Mycobacterium spp. was greater in the cement reactors (34.8 ± 18.6%) than in the cast iron reactors (21.7 ± 11.9%). In contrast, the mean relative abundance of Legionella spp. trended higher in biofilm from cast iron reactors (0.5 ± 0.7%) than biofilm in cement reactors (0.01 ± 0.01%). These results suggest that pipe material is associated with differences in the diversity, bacterial composition, and opportunistic pathogen prevalence in biofilm of DWDS.
Collapse
Affiliation(s)
- Debbie Lee
- Water, Health and Applied Microbiology Laboratory (WHAM Lab), Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, United States
| | - Gennaro Calendo
- Water, Health and Applied Microbiology Laboratory (WHAM Lab), Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, United States
| | - Kristin Kopec
- Water, Health and Applied Microbiology Laboratory (WHAM Lab), Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, United States
| | - Rebekah Henry
- Environmental and Public Health Microbiology Laboratory (EPHM Lab), Department of Civil Engineering, Monash University, Clayton, VIC, Australia
| | - Scott Coutts
- Micromon, Department of Microbiology, Monash University, Clayton, VIC, Australia
| | - David McCarthy
- Environmental and Public Health Microbiology Laboratory (EPHM Lab), Department of Civil Engineering, Monash University, Clayton, VIC, Australia
| | - Heather M. Murphy
- Water, Health and Applied Microbiology Laboratory (WHAM Lab), Department of Epidemiology and Biostatistics, College of Public Health, Temple University, Philadelphia, PA, United States
- Water, Health and Applied Microbiology Laboratory (WHAM Lab), Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON, Canada
| |
Collapse
|
33
|
Cameron ES, Schmidt PJ, Tremblay BJM, Emelko MB, Müller KM. Enhancing diversity analysis by repeatedly rarefying next generation sequencing data describing microbial communities. Sci Rep 2021; 11:22302. [PMID: 34785722 PMCID: PMC8595385 DOI: 10.1038/s41598-021-01636-1] [Citation(s) in RCA: 63] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 10/27/2021] [Indexed: 12/13/2022] Open
Abstract
Amplicon sequencing has revolutionized our ability to study DNA collected from environmental samples by providing a rapid and sensitive technique for microbial community analysis that eliminates the challenges associated with lab cultivation and taxonomic identification through microscopy. In water resources management, it can be especially useful to evaluate ecosystem shifts in response to natural and anthropogenic landscape disturbances to signal potential water quality concerns, such as the detection of toxic cyanobacteria or pathogenic bacteria. Amplicon sequencing data consist of discrete counts of sequence reads, the sum of which is the library size. Groups of samples typically have different library sizes that are not representative of biological variation; library size normalization is required to meaningfully compare diversity between them. Rarefaction is a widely used normalization technique that involves the random subsampling of sequences from the initial sample library to a selected normalized library size. This process is often dismissed as statistically invalid because subsampling effectively discards a portion of the observed sequences, yet it remains prevalent in practice and the suitability of rarefying, relative to many other normalization approaches, for diversity analysis has been argued. Here, repeated rarefying is proposed as a tool to normalize library sizes for diversity analyses. This enables (i) proportionate representation of all observed sequences and (ii) characterization of the random variation introduced to diversity analyses by rarefying to a smaller library size shared by all samples. While many deterministic data transformations are not tailored to produce equal library sizes, repeatedly rarefying reflects the probabilistic process by which amplicon sequencing data are obtained as a representation of the amplified source microbial community. Specifically, it evaluates which data might have been obtained if a particular sample's library size had been smaller and allows graphical representation of the effects of this library size normalization process upon diversity analysis results.
Collapse
Affiliation(s)
- Ellen S Cameron
- Department of Biology, University of Waterloo, 200 University Ave. W, Waterloo, ON, N2L 3G1, Canada
| | - Philip J Schmidt
- Department of Civil and Environmental Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON, N2L 3G1, Canada
| | - Benjamin J-M Tremblay
- Department of Biology, University of Waterloo, 200 University Ave. W, Waterloo, ON, N2L 3G1, Canada
| | - Monica B Emelko
- Department of Civil and Environmental Engineering, University of Waterloo, 200 University Ave. W, Waterloo, ON, N2L 3G1, Canada
| | - Kirsten M Müller
- Department of Biology, University of Waterloo, 200 University Ave. W, Waterloo, ON, N2L 3G1, Canada.
| |
Collapse
|
34
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
35
|
Hu D, Hong H, Rong B, Wei Y, Zeng J, Zhu J, Bai L, Guo F, Yu X. A comprehensive investigation of the microbial risk of secondary water supply systems in residential neighborhoods in a large city. WATER RESEARCH 2021; 205:117690. [PMID: 34614460 DOI: 10.1016/j.watres.2021.117690] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 09/15/2021] [Accepted: 09/19/2021] [Indexed: 06/13/2023]
Abstract
Secondary water supply systems (SWSSs) are characterized by long water stagnation and low levels of chlorine residuals, which may pose a high microbial risk to terminal users. In this study, the SWSSs of 12 residential neighborhoods in a metropolitan area of 5 million people in southeastern China were seasonally investigated to assess their microbial risks by determining more than 30 physicochemical and biological parameters. Although the microbiological quality of SWSS water met the requirements of the standards for drinking water quality of China, it did deteriorate in various aspects. The heterotrophic plate counts with R2A media were high (> 100 CFU/mL) in some SWSS tank and tap water samples. Propidium monoazide (PMA)-qPCR revealed a one magnitude higher abundance of viable bacteria in the tank and tap water samples (average 103.63±1.10 and 103.65±1.25 gene copies/mL, respectively) compared with the input water samples, and Enterococcus, Acanthamoeba, and Hartmannella vermiformis were only detected in the tanks. In particular, the high detection frequency of Legionella in 35% tank and 21% tap water samples suggested it is a supplementary microbial safety indicator in SWSSs. The microbial regrowth potential was more obvious in summer, and Illumina sequencing also demonstrated distinct seasonal changes in the relative abundance of bacterial gene sequences at the genus level. Turbidity and residual chlorine were closely connected with total bacterial biomass, and the latter seemed responsible for microbial community structure alteration. The extremely low chlorine residuals associated with a high abundance of total bacteria (as high as 106.48 gene copies/mL) and Legionella (as high as 106.71 gene copies/100 mL) in the closed valve tanks highlighted the high microbial risk increased by mishandling the operation of SWSSs. This study found that SWSSs possessed a higher microbial risk than the drinking water network, which suggested that the frequency and scope of monitoring the microbial risk of SWSSs in megacities should be strengthened for the purpose of waterborne epidemic disease prevention and control.
Collapse
Affiliation(s)
- Dong Hu
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Huarong Hong
- Xiamen Center for Disease Control and Prevention, Xiamen 361021, China
| | - Biao Rong
- Xiamen Center for Disease Control and Prevention, Xiamen 361021, China
| | - Yating Wei
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Jie Zeng
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Jun Zhu
- School of Life Sciences, Xiamen University, Xiamen 361102, China
| | - Lijun Bai
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Feng Guo
- School of Life Sciences, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
36
|
Han Z, Lu J, An W, Zhang Y, Yang M. Removal efficacy of opportunistic pathogen gene markers in drinking water supply systems: an in situ and large-scale molecular investigation. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:54153-54160. [PMID: 34389952 DOI: 10.1007/s11356-021-15744-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
The prevalence and interactions with biofilm and disinfectant of opportunistic pathogens in drinking water supply systems (DWSSs) have been extensively interpreted. In contrast, the large geographical distribution and in situ removal of opportunistic pathogens are overlooked aspects. Here, paired source and tap water samples of 36 parallel DWSSs across China were collected, with five common waterborne pathogens characterized by qPCR. From source to tap, the removal of bacterial biomass (16S rRNA gene copy number) was 1.10 log, and gene marker removal of five opportunistic pathogens ranged from 0.66 log to 2.27 log, with the order of Escherichia coli > Mycobacterium spp. > Clostridium perfringens > Bacillus cereus > Aeromonas hydrophila. Different with bacterial community, geographical location and source water types (river or reservoir) were not key contributor to variation of opportunistic pathogens. Gene marker removal efficacies of E. coli, Mycobacterium spp., and C. perfringens from source to tap were restricted to removal efficacy of overall bacterial biomass, while abundance of B. cereus in tap water linked to the input of B. cereus from source water. Although culture-dependent approach is important for pathogen enumeration in drinking water, qPCR-based molecular survey shows advantages of quantifiable high-throughput and easy operation, providing abundant and timely information on pathogen occurrence in water. This study provides the in situ, molecular-level evidence toward differential propagation features of multiple opportunistic pathogens in DWSSs and suggests the source protection and early warning of treatment-resistant pathogens.
Collapse
Affiliation(s)
- Ziming Han
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Junying Lu
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Wei An
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Yu Zhang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
- University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Min Yang
- University of Chinese Academy of Sciences, Beijing, 100049, China.
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| |
Collapse
|
37
|
Bian K, Wang C, Jia S, Shi P, Zhang H, Ye L, Zhou Q, Li A. Spatial dynamics of bacterial community in chlorinated drinking water distribution systems supplied with two treatment plants: An integral study of free-living and particle-associated bacteria. ENVIRONMENT INTERNATIONAL 2021; 154:106552. [PMID: 33866058 DOI: 10.1016/j.envint.2021.106552] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 03/01/2021] [Accepted: 03/30/2021] [Indexed: 06/12/2023]
Abstract
With the expansion of cities, the deterioration of drinking water quality undergoing complex and long-distance distribution is gaining increasing attention. However, spatial variations between free-living bacteria (FLB) and particle-associated bacteria (PAB) in chlorinated drinking water distribution systems (DWDSs) have not been fully explored, especially in complex water supply areas with multiple interconnected DWDSs. To fill this gap, this study utilized 16S rRNA approaches to characterize the spatial patterns of FLB and PAB in DWDSs with intersection regions. Based on distance-decay analysis, transportation distance is a potential driver of bacterial variation for both FLB (Pearson's r = -0.476, p < 0.01) and PAB. (Pearson's r = -0.352, p < 0.01). Moreover, the influence of transportation distance was further confirmed by a 1.20-99.45% decline in microbial contribution to the source of FLB and PAB communities in pipe water along the transportation pipelines. Meanwhile, significant difference (PERMANOVA, R2 = 0.14, p < 0.01) was found between FLB and PAB in DWDSs. Average proportions of Pseudomonas spp. were 59.84% and 45.59% for the PAB and intersection regions based on the 16S rRNA results, respectively, suggesting that PAB are potential reservoirs for high-risk bacteria, and a greater microbial risk may exist in intersection regions. In summary, transportation distance and pipeline intersection exerted significant impacts on the FLB and PAB in DWDSs. Therefore, precautionary strategies for controlling microbial risks that consider different microbial components and intersection regions in long-distance and multi-plant DWDSs should be implemented.
Collapse
Affiliation(s)
- Kaiqin Bian
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Chen Wang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Shuyu Jia
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Peng Shi
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
| | - Huaicheng Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Lin Ye
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Qing Zhou
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Aimin Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| |
Collapse
|
38
|
Zhou W, Li W, Chen J, Zhou Y, Wei Z, Gong L. Microbial diversity in full-scale water supply systems through sequencing technology: a review. RSC Adv 2021; 11:25484-25496. [PMID: 35478887 PMCID: PMC9037190 DOI: 10.1039/d1ra03680g] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 07/10/2021] [Indexed: 01/07/2023] Open
Abstract
The prevalence of microorganisms in full-scale water supply systems raises concerns about their pathogenicity and threats to public health. Clean tap water is essential for public health safety. The conditions of the water treatment process from the source water to tap water, including source water quality, water treatment processes, the drinking water distribution system (DWDS), and building water supply systems (BWSSs) in buildings, greatly influence the bacterial community in tap water. Given the importance of drinking water biosafety, the study of microbial diversity from source water to tap water is essential. With the development of molecular biology methods and bioinformatics in recent years, sequencing technology has been applied to study bacterial communities in full-scale water supply systems. In this paper, changes in the bacterial community and the influence of each treatment stage on microbial diversity in full-scale water supply systems are classified and analyzed. Microbial traceability analysis and control are discussed, and suggestions for future drinking water biosafety research and its prospects are proposed.
Collapse
Affiliation(s)
- Wei Zhou
- College of Environmental Science and Engineering, Tongji University Shanghai 200092 China
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University Shanghai 200092 China
| | - Weiying Li
- College of Environmental Science and Engineering, Tongji University Shanghai 200092 China
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University Shanghai 200092 China
| | - Jiping Chen
- College of Environmental Science and Engineering, Tongji University Shanghai 200092 China
| | - Yu Zhou
- College of Environmental Science and Engineering, Tongji University Shanghai 200092 China
| | - Zhongqing Wei
- Fuzhou Water Affairs Investment Development Co., Ltd. Fuzhou 350000 Fujian China
| | | |
Collapse
|
39
|
Alafaci A, Crépin A, Beaubert S, Berjeaud JM, Delafont V, Verdon J. Exploring the Individual Bacterial Microbiota of Questing Ixodes ricinus Nymphs. Microorganisms 2021; 9:microorganisms9071526. [PMID: 34361961 PMCID: PMC8303981 DOI: 10.3390/microorganisms9071526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/25/2021] [Accepted: 07/14/2021] [Indexed: 11/29/2022] Open
Abstract
Ixodes ricinus is the most common hard tick species in Europe and an important vector of pathogens of human and animal health concerns. The rise of high-throughput sequencing has facilitated the identification of many tick-borne pathogens and, more globally, of various microbiota members depending on the scale of concern. In this study, we aimed to assess the bacterial diversity of individual I. ricinus questing nymphs collected in France using high-throughput 16S gene metabarcoding. From 180 dragging-collected nymphs, we identified more than 700 bacterial genera, of which about 20 are abundantly represented (>1% of total reads). Together with 136 other genera assigned, they constitute a core internal microbiota in this study. We also identified 20 individuals carrying Borreliella. The most abundant species is B. afzelii, known to be one of the bacteria responsible for Lyme disease in Europe. Co-detection of up to four Borreliella genospecies within the same individual has also been retrieved. The detection and co-detection rate of Borreliella in I. ricinus nymphs is high and raises the question of interactions between these bacteria and the communities constituting the internal microbiota.
Collapse
|
40
|
Jing Z, Lu Z, Mao T, Cao W, Wang W, Ke Y, Zhao Z, Wang X, Sun W. Microbial composition and diversity of drinking water: A full scale spatial-temporal investigation of a city in northern China. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 776:145986. [PMID: 33640542 DOI: 10.1016/j.scitotenv.2021.145986] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/15/2021] [Accepted: 02/15/2021] [Indexed: 06/12/2023]
Abstract
The microbiological water quality of drinking water distribution systems (DWDSs) is of primary importance for public health. The detachment of biofilm attached on the pipe wall attribution to water source switch and the occurrence of potentially pathogenic chlorine-resistant bacteria (CRB) under chlorine disinfection get lots of attention. Studies examining microbial communities after the water source switch, particularly in low-salinity water, have been scant. The UV‑chlorine combined disinfection applied in one of the investigated drinking water plants provided insight into the control of CRBs. We applied high-throughput sequencing of the 16S rRNA gene to characterize the bacterial communities of the DWDS in northern China over 1 year. A network comprising four different DWDSs was sampled at 48 sites every season (temperate continental monsoon climate), and the impact of key spatial-temporal and physicochemical parameters was investigated. Overall, the entire bacterial community was not significantly different among the four DWDSs (spatial parameter) but varied with seasons (temporal parameter). The switch in water sources might increase the relative abundance of potentially opportunistic pathogens in DWDSs. UV‑chlorine combined disinfection can decrease community diversity and is likely to control the growth of potential opportunistic pathogens in DWDSs.
Collapse
Affiliation(s)
- Zibo Jing
- School of Environment, Tsinghua University, Beijing 100084, China; Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Zedong Lu
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Ted Mao
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China; MW Technologies, Inc., London, Ontario, Canada
| | - Wenfeng Cao
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Weibo Wang
- School of Environment, Tsinghua University, Beijing 100084, China
| | - Yanchu Ke
- School of Environment, Tsinghua University, Beijing 100084, China; State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Zhinan Zhao
- School of Environment, Tsinghua University, Beijing 100084, China; Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China
| | - Xiaohui Wang
- Beijing Engineering Research Center of Environmental Material for Water Purification, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou 215163, China.
| |
Collapse
|
41
|
Zhu Z, Shan L, Zhang X, Hu F, Zhong D, Yuan Y, Zhang J. Effects of bacterial community composition and structure in drinking water distribution systems on biofilm formation and chlorine resistance. CHEMOSPHERE 2021; 264:128410. [PMID: 33002803 DOI: 10.1016/j.chemosphere.2020.128410] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 08/25/2020] [Accepted: 09/19/2020] [Indexed: 06/11/2023]
Abstract
Community-intrinsic properties affect the composition and function of a microbial community. Understanding the microbial community-intrinsic properties in drinking water distribution systems (DWDS) could help to select disinfection strategies and aid in the prevention of waterborne infectious diseases. In this study, we investigated the formation of multi-species biofilms in six groups, each consisting of four or five mixed bacterial strains isolated from a simulated DWDS, at different incubation times (24, 48, and 72 h). We then evaluated the chlorine resistance of the 72-h multi-species biofilms in the presence of 0.3, 0.6, 1, 2, 4, and 10 mg/L residual chlorine. Microbacterium laevaniformans inhibited the formation of multi-species biofilms, Sphingomonas sp., Acinetobacter sp. and A. deluvii had the effect of promoting their growth, and B. cereus has little effect on the growth of multi-species biofilms. However, these inhibition and promotion effects were weak and inadequate to completely control the growth of multi-species biofilms. All multi-species produced strong biofilms after 72 h incubation, which could be due to microbial community-intrinsic properties. Community-intrinsic properties could maintain high EPS production and cell-to-cell connections in multi-species biofilms, and could affect the formation of multi-species biofilms. The chlorine resistance of multi-species biofilms was significantly improved by B. cereus, but significantly reduced by M. laevaniformans. These results indicated that the microbial community-intrinsic properties were influenced by the environment. At a relatively low disinfectant concentration (<2 mg/L residual chlorine), the community-intrinsic properties were maintained; however, when the disinfectant concentration was increased to 2-4 mg/L residual chlorine, the community-intrinsic properties weakened, and significantly affected the resistance of the microbial communities to the disinfectant. With further increases in concentration, to >4 mg/L residual chlorine, no significant difference was observed in the disinfectant resistance of the microbial community.
Collapse
Affiliation(s)
- Zebing Zhu
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, PR China; State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China.
| | - Lili Shan
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, PR China
| | - Xinyun Zhang
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, PR China
| | - Fengping Hu
- School of Civil Engineering and Architecture, East China Jiao Tong University, Nanchang, 330013, PR China.
| | - Dan Zhong
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China
| | - Yixing Yuan
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China
| | - Jie Zhang
- State Key Laboratory of Urban Water Resource and Environment, School of Environment, Harbin Institute of Technology, Harbin, 150090, PR China
| |
Collapse
|
42
|
Zea L, McLean RJ, Rook TA, Angle G, Carter DL, Delegard A, Denvir A, Gerlach R, Gorti S, McIlwaine D, Nur M, Peyton BM, Stewart PS, Sturman P, Velez Justiniano YA. Potential biofilm control strategies for extended spaceflight missions. Biofilm 2020; 2:100026. [PMID: 33447811 PMCID: PMC7798464 DOI: 10.1016/j.bioflm.2020.100026] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 05/08/2020] [Accepted: 05/24/2020] [Indexed: 01/10/2023] Open
Abstract
Biofilms, surface-adherent microbial communities, are associated with microbial fouling and corrosion in terrestrial water-distribution systems. Biofilms are also present in human spaceflight, particularly in the Water Recovery System (WRS) on the International Space Station (ISS). The WRS is comprised of the Urine Processor Assembly (UPA) and the Water Processor Assembly (WPA) which together recycles wastewater from human urine and recovered humidity from the ISS atmosphere. These wastewaters and various process streams are continually inoculated with microorganisms primarily arising from the space crew microbiome. Biofilm-related fouling has been encountered and addressed in spacecraft in low Earth orbit, including ISS and the Russian Mir Space Station. However, planned future missions beyond low Earth orbit to the Moon and Mars present additional challenges, as resupplying spare parts or support materials would be impractical and the mission timeline would be in the order of years in the case of a mission to Mars. In addition, future missions are expected to include a period of dormancy in which the WRS would be unused for an extended duration. The concepts developed in this review arose from a workshop including NASA personnel and representatives with biofilm expertise from a wide range of industrial and academic backgrounds. Here, we address current strategies that are employed on Earth for biofilm control, including antifouling coatings and biocides and mechanisms for mitigating biofilm growth and damage. These ideas are presented in the context of their applicability to spaceflight and identify proposed new topics of biofilm control that need to be addressed in order to facilitate future extended, crewed, spaceflight missions.
Collapse
Affiliation(s)
- Luis Zea
- BioServe Space Technologies, University of Colorado, Boulder, CO, USA
| | | | | | | | | | | | | | - Robin Gerlach
- Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | - Sridhar Gorti
- NASA Marshall Spaceflight Center, Huntsville, AL, USA
| | | | - Mononita Nur
- NASA Marshall Spaceflight Center, Huntsville, AL, USA
| | - Brent M. Peyton
- Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | - Philip S. Stewart
- Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | - Paul Sturman
- Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | | |
Collapse
|
43
|
Cullom AC, Martin RL, Song Y, Williams K, Williams A, Pruden A, Edwards MA. Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens. Pathogens 2020; 9:E957. [PMID: 33212943 PMCID: PMC7698398 DOI: 10.3390/pathogens9110957] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/12/2020] [Accepted: 11/13/2020] [Indexed: 12/20/2022] Open
Abstract
Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper's interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.
Collapse
Affiliation(s)
- Abraham C. Cullom
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | - Rebekah L. Martin
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
- Civil and Environmental Engineering, Virginia Military Institute, Lexington, VA 24450, USA
| | - Yang Song
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | | | - Amanda Williams
- c/o Marc Edwards, Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA;
| | - Amy Pruden
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| | - Marc A. Edwards
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, VA 24061, USA; (A.C.C.); (R.L.M.); (Y.S.); (A.P.)
| |
Collapse
|
44
|
Spatiotemporal Changes of Antibiotic Resistance and Bacterial Communities in Drinking Water Distribution System in Wrocław, Poland. WATER 2020. [DOI: 10.3390/w12092601] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Antibiotic resistance of bacteria is an emerging problem in drinking water treatment. This paper presents the comparison of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) prevalence during the summer and winter season in a full-scale drinking water distribution system (DWDS) supplied by two water treatment plants (WTPs). The effect of distance from WTP and physical–chemical water parameters on its microbial properties was also tested. Bacterial consortia dwelling in bulk tap water were additionally compared by means of denaturating gradient gel electrophoresis (DGGE). The results showed that among ARB, bacteria resistant to ceftazidime (CAZ) were the most abundant, followed by bacteria resistant to amoxicillin (AML), ciprofloxacin (CIP), and tetracycline (TE). Numerous ARGs were detected in tested tap water samples. Only CAZ resistant bacteria were more prevalent in the season of increased antibiotic consumption, and only AML resistant bacteria relative abundances increase was statistically significant with the distance from a WTP. The investigated tap water meets all legal requirements. It is therefore safe to drink according to the law. Nevertheless, because antibiotic resistance could pose a threat to consumer health, it should be further monitored in DWDSs.
Collapse
|
45
|
Sala-Comorera L, Caudet-Segarra L, Galofré B, Lucena F, Blanch AR, García-Aljaro C. Unravelling the composition of tap and mineral water microbiota: Divergences between next-generation sequencing techniques and culture-based methods. Int J Food Microbiol 2020; 334:108850. [PMID: 32919261 DOI: 10.1016/j.ijfoodmicro.2020.108850] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/22/2020] [Accepted: 08/24/2020] [Indexed: 01/04/2023]
Abstract
The complex and highly diverse microbial environment of drinking water, consisting mainly of bacteria at different metabolic states, is still underexplored. The aim of this work was to characterize the bacterial communities in tap water and bottled mineral water, the two predominant sources of drinking water in modern societies. A total of 11 tap water samples from a range of locations and distribution networks and 10 brands of bottled natural mineral water were analysed using two approaches: a) heterotrophic plate counts by matrix-assisted laser desorption/ionization time of flight mass-spectrometry (MALDI-TOF MS) for the culturable heterotrophic communities, and b) Illumina amplicon sequencing for total bacteria including non-culturable bacteria. Culturable heterotrophic bacteria were isolated in WPCA (ISO) agar at 22 ± 2 °C for 72 h and 2046 isolates were identified using MALDI-TOF MS. The Bruker Daltonics Library and a previously customized library (Drinking Water Library) were used as reference databases. For the total bacteria fraction, DNA was extracted from 6 L of water and submitted to Illumina 16S rRNA sequencing of the v4 region. Significant differences were observed between mineral and tap water, with a general dominance of Alphaproteobacteria (mainly the genus Blastomonas) in tap water and Gammaproteobacteria in mineral water with Acidovorax being the dominant genus in 3 out of 7 mineral water brands. The bacterial communities in the different brands of mineral water were highly diverse and characteristic of each one. Moreover, the season in which the water was bottled also affected the species distribution, with some of them identified in only one season. Among the culturable bacteria, the most abundant phylum was Proteobacteria (around 85% of the isolates), followed by Actinobacteria, Firmicutes and Bacteroidetes. Proteobacteria was also the most abundant phylum detected with Illumina sequencing (>99% of the reads). The two methods gave distinct results at the different taxonomic levels and could therefore have a complimentary application in the study of microbiota in mineral water environments. MALDI-TOF MS is a promising method for the rapid identification of heterotrophic bacteria in routine water analysis in the bottling industry. SIGNIFICANCE AND IMPACT OF THE STUDY: The complementarity of MALDI-TOF MS and NGS in the assessment of bacterial community diversity has been demonstrated in water intended for human consumption. The two methods are suitable for routine use in the water industry for water quality management.
Collapse
Affiliation(s)
- Laura Sala-Comorera
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, E-08028 Barcelona. Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001 Barcelona, Spain
| | - Laia Caudet-Segarra
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, E-08028 Barcelona. Spain
| | - Belén Galofré
- Aigües de Barcelona, EMGCIA, C/General Batet 1-7, 08028 Barcelona, Spain
| | - Francisco Lucena
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, E-08028 Barcelona. Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001 Barcelona, Spain
| | - Anicet R Blanch
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, E-08028 Barcelona. Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001 Barcelona, Spain
| | - Cristina García-Aljaro
- Department of Genetics, Microbiology and Statistics, Faculty of Biology, University of Barcelona, Diagonal 643, E-08028 Barcelona. Spain; The Water Research Institute, University of Barcelona, Montalegre 6, 08001 Barcelona, Spain.
| |
Collapse
|
46
|
Current Progression: Application of High-Throughput Sequencing Technique in Space Microbiology. BIOMED RESEARCH INTERNATIONAL 2020; 2020:4094191. [PMID: 32685480 PMCID: PMC7327617 DOI: 10.1155/2020/4094191] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 05/01/2020] [Indexed: 11/17/2022]
Abstract
During a spaceflight, astronauts need to live in a spacecraft on orbit for a long time, and the relationship between humans and microorganisms in the closed environment of space is not the same as on the ground. The dynamic study of microorganisms in confined space shows that with the extension of the isolation time, harmful bacteria gradually accumulate. Monitoring and controlling microbial pollution in a confined environment system are very important for crew health and the sustainable operation of a space life support system. Culture-based assays have been used traditionally to assess the microbial loads in a spacecraft, and uncultured-based techniques are already under way according to the NASA global exploration roadmap. High-throughput sequencing technology has been used generally to study the communities of the environment and human on the ground and shows its broad prospects applied onboard. We here review the recent application of high-throughput sequencing on space microbiology and analyze its feasibility and potential as an on-orbit detection technology.
Collapse
|
47
|
Yu Z, Zhang Y, Zhang Z, Dong J, Fu J, Xu X, Zhu L. Enhancement of PPCPs removal by shaped microbial community of aerobic granular sludge under condition of low C/N ratio influent. JOURNAL OF HAZARDOUS MATERIALS 2020; 394:122583. [PMID: 32289623 DOI: 10.1016/j.jhazmat.2020.122583] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 03/10/2020] [Accepted: 03/23/2020] [Indexed: 06/11/2023]
Abstract
The frequent occurrence of pharmaceuticals and personal care products (PPCPs) in domestic wastewater has caused great concern. In this study, the removal of two typical pharmaceuticals (Roxithromycin, ROX; Sulfamethoxazole, SMZ) in aerobic granular sludge (AGS) reactors was investigated under condition of different C/N (carbon to nitrogen) ratios. Results showed that higher removal efficiencies of ROX and SMZ (95.2 % and 92.9 %) were achieved in the AGS reactor fed with low C/N influent. Batch experiments further revealed that the removal of ROX was influenced by the adsorption ability of the AGS while SMZ removal was mainly enhanced by biodegradation process. Analysis of extracellular polymeric substances (EPS) showed that the humic acid-like substances were enriched under low C/N condition, which was in accordance with dynamic change of microbial community. The microbes, like Thauera spp. and Xanthomonadaceae, were highly enriched in the reactor with high nitrogen loading rate and functioned as refractory organics degrader. Overall, the AGS process could achieve enhanced pharmaceuticals removal performance by the regulation of microbial community under low C/N influent, which provides insights into a feasible solution for simultaneous removal of nitrogen and trace organic pollutants in AGS reactor.
Collapse
Affiliation(s)
- Zhuodong Yu
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China
| | - Ye Zhang
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China
| | - Zhiming Zhang
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China
| | - Jingjing Dong
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China
| | - Jiashen Fu
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China
| | - Xiangyang Xu
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China; Zhejiang Province Key Laboratory for Water Pollution Control and Environmental Safety, Hangzhou 310058, China; Zhejiang Provincial Engineering Laboratory of Water Pollution Control, 388 Yuhangtang Road, Hangzhou 310058, China
| | - Liang Zhu
- Institute of Environmental Pollution Control and Treatment, Zhejiang University, Hangzhou 310058, China; Zhejiang Province Key Laboratory for Water Pollution Control and Environmental Safety, Hangzhou 310058, China; Zhejiang Provincial Engineering Laboratory of Water Pollution Control, 388 Yuhangtang Road, Hangzhou 310058, China.
| |
Collapse
|
48
|
Cruz MC, Woo Y, Flemming HC, Wuertz S. Nitrifying niche differentiation in biofilms from full-scale chloraminated drinking water distribution system. WATER RESEARCH 2020; 176:115738. [PMID: 32259683 DOI: 10.1016/j.watres.2020.115738] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Revised: 03/16/2020] [Accepted: 03/17/2020] [Indexed: 06/11/2023]
Abstract
Tropical conditions favour the auto-decomposition of monochloramine (MCA) leading to disinfectant decay and free ammonia in drinking water distribution systems (DWDS); thus, they promote the growth of nitrifiers and the development of biofilms on the inner-pipe surface. Biofilms can adversely impact the provision of safe and biologically stable water. Moreover, there is a general lack of understanding of the role of microbial communities in DWDS in regions with warm temperatures and no distinct seasons. Here, we report a survey on biofilms from full-scale monochloraminated DWDS in a highly urbanised metropolis using next generation sequencing tools. The monitoring campaign consisted of sampling biofilms and bulk waters from 21 in-service pipes. We characterized the microbial community with emphasis on nitrifying bacteria and archaea using 16S rRNA gene amplicon sequencing and potential nitrification activity. Samples grouped into two clusters, characterized by their low (Cluster LD) and high (Cluster HD) α-diversity. Both clusters harbour microorganisms related to nitrification: i) Nitrosomonas (24.9-68.8%), an ammonia oxidising bacterium (AOB) that dominated Cluster LD, and ii) a co-aggregation of genus Nitrospira (9.8-32.5%), a nitrite oxidising bacterium (NOB), and Thaumarchaeota (1.4-10.9%), chemolithotrophic ammonia oxidising (AOA) archaea that were among the most abundant OTUs in Cluster HD. Activity tests performed with fresh biofilm samples confirmed that these two clusters represent distinctive biofilm niches performing different stages of the nitrification process. Cluster LD correlated with a high concentration of MCA, which caused dysbiosis and resulted in high unevenness of the cluster. In cluster HD, with more biomass, chemical reactions involving nitrite increased the MCA demand, releasing ammonia and allowing more nitrifiers to grow, like AOA and NOB. From this study, we conclude that an MCA residual gradient along the DWDS drives and shapes the microbial community assembly and should be considered when designing effective disinfection strategies.
Collapse
Affiliation(s)
- Mercedes Cecilia Cruz
- Singapore Centre for Environmental Life Sciences Engineering (SCELSE), 60 Nanyang Drive, Nanyang Technological University, 637551, Singapore
| | - Yissue Woo
- Singapore Centre for Environmental Life Sciences Engineering (SCELSE), 60 Nanyang Drive, Nanyang Technological University, 637551, Singapore
| | - Hans-Curt Flemming
- Singapore Centre for Environmental Life Sciences Engineering (SCELSE), 60 Nanyang Drive, Nanyang Technological University, 637551, Singapore
| | - Stefan Wuertz
- Singapore Centre for Environmental Life Sciences Engineering (SCELSE), 60 Nanyang Drive, Nanyang Technological University, 637551, Singapore; School of Civil and Environmental Engineering, 50 Nanyang Ave, Nanyang Technological University, 639798, Singapore.
| |
Collapse
|
49
|
Brester C, Ryzhikov I, Siponen S, Jayaprakash B, Ikonen J, Pitkänen T, Miettinen IT, Torvinen E, Kolehmainen M. Potential and limitations of a pilot-scale drinking water distribution system for bacterial community predictive modelling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 717:137249. [PMID: 32092807 DOI: 10.1016/j.scitotenv.2020.137249] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 02/09/2020] [Accepted: 02/09/2020] [Indexed: 06/10/2023]
Abstract
Waterborne disease outbreaks are a persistent and serious threat to public health according to reported incidents across the globe. Online drinking water quality monitoring technologies have evolved substantially and have become more accurate and accessible. However, using online measurements alone is unsuitable for detecting microbial regrowth, potentially including harmful species, ahead of time in the distribution systems. Alternatively, observational data could be collected periodically, e.g. once per week or once per month and it could include a representative set of variables: physicochemical water characteristics, disinfectant concentrations, and bacterial abundances, which would be a valuable source of knowledge for predictive modelling that aims to reveal pathogen-related threats. In this study, we utilised data collected from a pilot-scale drinking water distribution system. A data-driven random forest model was used for predictive modelling and was trained for nowcasting and forecasting abundances of bacterial groups. In all the experiments, we followed the realistic crossline scenario, which means that when training and testing the models the data is collected from different pipelines. In spite of the more accurate results of the nowcasting, the 1-week forecasting still provided accurate predictions of the most abundant bacteria, their rapid increase and decrease. In the future predictive modelling might be used as a tool in designing control measures for opportunistic pathogens which are able to multiply in the favourable conditions in drinking water distribution systems (DWDS). Eventually, the forecasting information will be able to produce practically helpful data for controlling the DWDS regrowth.
Collapse
Affiliation(s)
- Christina Brester
- Department of Environmental and Biological Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland.
| | - Ivan Ryzhikov
- Department of Environmental and Biological Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland
| | - Sallamaari Siponen
- Department of Environmental and Biological Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland
| | - Balamuralikrishna Jayaprakash
- Department of Health Security, Expert Microbiology Unit, National Institute for Health and Welfare, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Jenni Ikonen
- Department of Health Security, Expert Microbiology Unit, National Institute for Health and Welfare, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Tarja Pitkänen
- Department of Health Security, Expert Microbiology Unit, National Institute for Health and Welfare, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Ilkka T Miettinen
- Department of Health Security, Expert Microbiology Unit, National Institute for Health and Welfare, P.O. Box 95, FI-70701 Kuopio, Finland
| | - Eila Torvinen
- Department of Environmental and Biological Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland
| | - Mikko Kolehmainen
- Department of Environmental and Biological Sciences, University of Eastern Finland, P.O. Box 1627, FI-70211 Kuopio, Finland
| |
Collapse
|
50
|
Brumfield KD, Hasan NA, Leddy MB, Cotruvo JA, Rashed SM, Colwell RR, Huq A. A comparative analysis of drinking water employing metagenomics. PLoS One 2020; 15:e0231210. [PMID: 32271799 PMCID: PMC7145143 DOI: 10.1371/journal.pone.0231210] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Accepted: 03/18/2020] [Indexed: 12/13/2022] Open
Abstract
The microbiological content of drinking water traditionally is determined by employing culture-dependent methods that are unable to detect all microorganisms, especially those that are not culturable. High-throughput sequencing now makes it possible to determine the microbiome of drinking water. Thus, the natural microbiota of water and water distribution systems can now be determined more accurately and analyzed in significantly greater detail, providing comprehensive understanding of the microbial community of drinking water applicable to public health. In this study, shotgun metagenomic analysis was performed to determine the microbiological content of drinking water and to provide a preliminary assessment of tap, drinking fountain, sparkling natural mineral, and non-mineral bottled water. Predominant bacterial species detected were members of the phyla Actinobacteria and Proteobacteria, notably the genera Alishewanella, Salmonella, and Propionibacterium in non-carbonated non-mineral bottled water, Methyloversatilis and Methylibium in sparkling natural mineral water, and Mycobacterium and Afipia in tap and drinking fountain water. Fecal indicator bacteria, i.e., Escherichia coli or enterococci, were not detected in any samples examined in this study. Bacteriophages and DNA encoding a few virulence-associated factors were detected but determined to be present only at low abundance. Antibiotic resistance markers were detected only at abundance values below our threshold of confidence. DNA of opportunistic plant and animal pathogens was identified in some samples and these included bacteria (Mycobacterium spp.), protozoa (Acanthamoeba mauritaniensis and Acanthamoeba palestinensis), and fungi (Melampsora pinitorqua and Chryosporium queenslandicum). Archaeal DNA (Candidatus Nitrosoarchaeum) was detected only in sparkling natural mineral water. This preliminary study reports the complete microbiome (bacteria, viruses, fungi, and protists) of selected types of drinking water employing whole-genome high-throughput sequencing and bioinformatics. Investigation into activity and function of the organisms detected is in progress.
Collapse
Affiliation(s)
- Kyle D. Brumfield
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
| | - Nur A. Hasan
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Menu B. Leddy
- Essential Environmental and Engineering Systems, Huntington Beach, CA, United States of America
| | - Joseph A. Cotruvo
- Joseph Cotruvo and Associates LLC, Washington, DC, United States of America
| | - Shah M. Rashed
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Rita R. Colwell
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
- University of Maryland Institute for Advanced Computer Studies, University of Maryland, College Park, MD, United States of America
- CosmosID Inc., Rockville, MD, United States of America
| | - Anwar Huq
- Maryland Pathogen Research Institute, University of Maryland, MD, College Park, United States of America
| |
Collapse
|