1
|
Kuzin AA, Sobolev DI, Eliferov VA, Stupnikova GS, Popov IA, Nikolaev EN, Pekov SI. Matrix-assisted laser desorption/ionization matrix incorporation evaluation algorithm for improved peak coverage and signal-to-noise ratio in mass spectrometry imaging. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2024; 38:e9830. [PMID: 38813850 DOI: 10.1002/rcm.9830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/08/2024] [Accepted: 05/08/2024] [Indexed: 05/31/2024]
Abstract
RATIONALE Despite decades of implementation, the selection of optimal sample preparation conditions for matrix-assisted laser desorption/ionization (MALDI) imaging is still ambiguous due to the lack of a universal and comprehensive evaluation methodology. Thus, numerous experiments with different matrix application conditions accompany a translation of the method to novel sample types and matrices. METHODS Mouse brain tissues were covered with 9-aminoacridine through sublimation, followed by recrystallization in vapors of 5% (v/v) methanol solution in water. The samples were analyzed by MALDI time-of-flight mass spectrometry, and the efficiency of lipid and small-molecule ionization was evaluated with different metrics. RESULTS We first investigate the dependency of matrix density and recrystallization conditions on the thickness of an analyte-empty matrix layer to roughly evaluate the laser shot number required to obtain an intense signal with minimal noise. Then, we introduce metrics for the analysis of small imaging datasets (small sample regions) of model samples based on median quantity of peaks in spectra (medQP) and weighted median signal-to-noise ratio (wmSNR). The evaluation of small regions and taking median values for metrics help overcome the sample heterogeneity and allow for the simultaneous comparison of different acquisition parameters. CONCLUSIONS Here, we propose a methodology based on gradual laser ablation of small regions of sample and further implementation of weighted signal-to-noise ratio to assess various matrix application conditions. The proposed approach helps reduce the number of test samples required to determine optimal sample preparation conditions and improve the overall quality of images.
Collapse
Affiliation(s)
- Andrey A Kuzin
- Laboratory for Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | - Daniil I Sobolev
- Laboratory for Mass Spectrometry, Skolkovo Institute of Science and Technology, Moscow, Russian Federation
| | - Vasiliy A Eliferov
- Laboratory for Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | - Galina S Stupnikova
- Laboratory for Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| | - Igor A Popov
- Laboratory for Molecular Medical Diagnostics, Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
- Laboratory for Translational Medicine, Siberian State Medical University, Tomsk, Russian Federation
| | - Eugene N Nikolaev
- Laboratory for Mass Spectrometry, Skolkovo Institute of Science and Technology, Moscow, Russian Federation
| | - Stanislav I Pekov
- Laboratory for Mass Spectrometry, Skolkovo Institute of Science and Technology, Moscow, Russian Federation
- Laboratory for Translational Medicine, Siberian State Medical University, Tomsk, Russian Federation
- Department of Molecular and Biological Physics, Moscow Institute of Physics and Technology, Dolgoprudny, Russian Federation
| |
Collapse
|
2
|
Weintraut T, Heiles S, Gerbig D, Henss A, Junck J, Düring RA, Rohnke M. Lipid-related ion suppression on the herbicide atrazine in earthworm samples in ToF-SIMS and matrix-assisted laser desorption ionization mass spectrometry imaging and the role of gas-phase basicity. Biointerphases 2024; 19:021003. [PMID: 38602440 DOI: 10.1116/6.0003437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 03/18/2024] [Indexed: 04/12/2024] Open
Abstract
In mass spectrometry imaging (MSI), ion suppression can lead to a misinterpretation of results. Particularly phospholipids, most of which exhibit high gas-phase basicity (GB), are known to suppress the detection of metabolites and drugs. This study was initiated by the observation that the signal of an herbicide, i.e., atrazine, was suppressed in MSI investigations of earthworm tissue sections. Herbicide accumulation in earthworms was investigated by time-of-flight secondary ion mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Additionally, earthworm tissue sections without accumulation of atrazine but with a homogeneous spray deposition of the herbicide were analyzed to highlight region-specific ion suppression. Furthermore, the relationship of signal intensity and GB in binary mixtures of lipids, amino acids, and atrazine was investigated in both MSI techniques. The GB of atrazine was determined experimentally through a linear plot of the obtained intensity ratios of the binary amino acid mixtures, as well as theoretically. The GBs values for atrazine of 896 and 906 kJ/mol in ToF-SIMS and 933 and 987 kJ/mol in MALDI-MSI were determined experimentally and that of 913 kJ/mol by quantum mechanical calculations. Compared with the GB of a major lipid component, phosphatidylcholine (GBPC = 1044.7 kJ/mol), atrazine's experimentally and computationally determined GBs in this work are significantly lower, making it prone to ion suppression in biological samples containing polar lipids.
Collapse
Affiliation(s)
- Timo Weintraut
- Institute of Physical Chemistry, Justus Liebig University Giessen, Heinrich-Buff-Ring 17, Giessen 35392, Germany
| | - Sven Heiles
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V., Otto-Hahn-Straße 6b, Dortmund 44139, Germany
- Faculty of Chemistry, University of Duisburg-Essen, Universitaetsstrasse 5, Essen 45141, Germany
- Institute of Inorganic and Analytical Chemistry, Justus Liebig University Giessen, Heinrich-Buff-Ring 17, Giessen 35392, Germany
| | - Dennis Gerbig
- Institute of Organic Chemistry, Justus Liebig University Giessen, Heinrich-Buff-Ring 17, Giessen 35392, Germany
| | - Anja Henss
- Institute of Physical Chemistry, Justus Liebig University Giessen, Heinrich-Buff-Ring 17, Giessen 35392, Germany
| | - Johannes Junck
- Institute of Soil Science and Soil Conservation, Research Center for Biosystems, Land Use and Nutrition, Justus Liebig University Giessen, Heinrich-Buff-Ring 26-32, Giessen 35392, Germany
| | - Rolf-Alexander Düring
- Institute of Soil Science and Soil Conservation, Research Center for Biosystems, Land Use and Nutrition, Justus Liebig University Giessen, Heinrich-Buff-Ring 26-32, Giessen 35392, Germany
| | - Marcus Rohnke
- Institute of Physical Chemistry, Justus Liebig University Giessen, Heinrich-Buff-Ring 17, Giessen 35392, Germany
| |
Collapse
|
3
|
Alvarez-Martin A, Quanico J, Scovacricchi T, Avranovich Clerici E, Baggerman G, Janssens K. Chemical Mapping of the Degradation of Geranium Lake in Paint Cross Sections by MALDI-MSI. Anal Chem 2023. [PMID: 37994904 DOI: 10.1021/acs.analchem.3c03992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2023]
Abstract
Matrix assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) has become a powerful method to extract spatially resolved chemical information in complex materials. This study provides the first use of MALDI-MSI to define spatial-temporal changes in oil paints. Due to the highly heterogeneous nature of oil paints, the sample preparation had to be optimized to prevent molecules from delocalizing. Here, we present a new protocol for the layer-specific analysis of oil paint cross sections achieving a lateral resolution of 10 μm and without losing ionization efficiency due to topographic effects. The efficacy of this method was investigated in oil paint samples containing a mixture of two historic organic pigments, geranium lake and lead white, a mixture often employed in the work of painter Vincent Van Gogh. This methodology not only allows for spatial visualization of the molecules responsible for the pink hue of the paint but also helps to elucidate the chemical changes behind the discoloration of paintings with this composition. The results demonstrate that this approach provides valuable molecular compositional information about the degradation pathways of pigments in specific paint layers and their interaction with the binding medium and other paint components and with light over time. Since a spatial correlation between molecular species and the visual pattern of the discoloration pattern can be made, we expect that mass spectrometry imaging will become highly relevant in future degradation studies of many more historical pigments and paints.
Collapse
Affiliation(s)
- Alba Alvarez-Martin
- AXIS, NANOLab Centre of Excellence, Department of Physics, University of Antwerp, 2020 Antwerpen, Belgium
- Conservation and Science, Rijksmuseum Amsterdam, 1071 ZC Amsterdam, The Netherlands
- Royal Museum for Central Africa, 3080 Tervuren, Belgium
| | - Jusal Quanico
- Center for Proteomics, University of Antwerp, 2020 Antwerpen, Belgium
| | - Teresa Scovacricchi
- AXIS, NANOLab Centre of Excellence, Department of Physics, University of Antwerp, 2020 Antwerpen, Belgium
| | - Ermanno Avranovich Clerici
- AXIS, NANOLab Centre of Excellence, Department of Physics, University of Antwerp, 2020 Antwerpen, Belgium
| | - Geert Baggerman
- Center for Proteomics, University of Antwerp, 2020 Antwerpen, Belgium
| | - Koen Janssens
- AXIS, NANOLab Centre of Excellence, Department of Physics, University of Antwerp, 2020 Antwerpen, Belgium
- Conservation and Science, Rijksmuseum Amsterdam, 1071 ZC Amsterdam, The Netherlands
| |
Collapse
|
4
|
Adolphs T, Heeger M, Bosse F, Ravoo BJ, Peterson RE, Arlinghaus HF, Tyler BJ. Matrix-Enhanced SIMS: The Influence of Primary Ion Species and Cluster Size on Ion Yield and Ion Yield Enhancement of Lipids. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2211-2221. [PMID: 37713531 DOI: 10.1021/jasms.3c00173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/17/2023]
Abstract
Time-of-flight secondary ion mass spectrometry is one of the most promising techniques for label-free analysis of biomolecules with nanoscale spatial resolution. However, high-resolution imaging of larger biomolecules such as phospholipids and peptides is often hampered by low yields of molecular ions. Matrix-enhanced SIMS (ME-SIMS), in which an organic matrix is added to the sample, is one promising approach to enhancing the ion yield for biomolecules. Optimizing this approach has, however, been challenging because the processes involved in increasing the ion yield in ME-SIMS are not yet fully understood. In this work, the matrix α-cyano-4-hydroxycinnamic acid (HCCA) has been combined with cluster primary ion analysis to better understand the roles of proton donation and reduced fragmentation on lipid molecule ion yield. A model system consisting of 1:100 mol ratio dipalmitoylphosphatidylcholine (DPPC) in HCCA as well as an HCCA-coated mouse brain cryosection have been studied using a range of Bi and Ar cluster ions. Although the molecular ion yield increased with an increase in cluster ion size, the enhancement of the signals from intact lipid molecules decreased with an increase in cluster ion size for both the model system and the mouse brain. Additionally, in both systems, protonated molecular ions were significantly more enhanced than sodium and potassium cationized molecules for all of the primary ions utilized. For the model system, the DPPC molecular ion yield was increased by more than an order of magnitude for all of the primary ions studied, and fragmentation of DPPC was dramatically reduced. However, on the brain sample, even though the HCCA matrix reduced DPPC fragmentation for all of the primary ions studied, the matrix coating suppressed the ion yield for some lipids when the larger cluster primary ions were employed. This indicated insufficient migration of the lipids into the matrix coating, so that dilution by the matrix overpowered the enhancement effect. This study provides strong evidence that the HCCA matrix both enhances protonation and reduces fragmentation. For imaging applications, the ability of the analytes to migrate to the surface of the matrix coating is also a critical factor for useful signal enhancement. This work demonstrates that the HCCA matrix provides a softer desorption environment when using Bi cluster ions than that obtained using the large gas cluster ions studied alone, indicating the potential for improved high spatial resolution imaging with ME-SIMS.
Collapse
Affiliation(s)
- Thorsten Adolphs
- Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany
- Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany
| | - Marcel Heeger
- Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany
| | - Florian Bosse
- Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany
- Organic Chemistry Institute, Westfälische Wilhelms-Universität, Corrensstrasse 36, 48149 Münster, Germany
| | - Bart Jan Ravoo
- Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany
- Organic Chemistry Institute, Westfälische Wilhelms-Universität, Corrensstrasse 36, 48149 Münster, Germany
| | - Richard E Peterson
- Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany
| | - Heinrich F Arlinghaus
- Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany
- Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany
| | - Bonnie J Tyler
- Institute of Physics, Westfälische Wilhelms-Universität, Wilhelm-Klemm-Straße 10, 48149 Münster, Germany
- Center for Soft Nanoscience (SoN), Westfälische Wilhelms-Universität, Busso-Peus-Straße 10, 48149 Münster, Germany
| |
Collapse
|
5
|
Tomasetti B, Lauzin C, Delcorte A. Enhancing Ion Signals and Improving Matrix Selection in Time-of-Flight Secondary Ion Mass Spectrometry with Microvolume Expansion Using Large Argon Clusters. Anal Chem 2023; 95:13620-13628. [PMID: 37610942 DOI: 10.1021/acs.analchem.3c02404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
The molecular environment has an important impact on the ionization mechanism in time-of-flight secondary ion mass spectrometry (ToF-SIMS). In complex samples, desorption/ionization, and thus the detection of a molecular signal, can be hampered by molecular entanglement, ionization-suppressive neighbors, or even an unfavorable sample substrate. Here, a method called microvolume expansion is developed to overcome these negative effects. Large argon clusters are able to transfer biomolecules from a target to a collector in vacuum. In this study, argon gas cluster ion beams (Arn+-GCIB with n centered around 3000 or 5000) are used to expand a microvolume from the sample to a collector, which is a material ideally enhancing the ionization yield. The collector is then analyzed using a liquid metal ion gun. The signal amplification factor corresponding to the expansion of phosphatidylcholine (PC) lipid on collectors partially covered with acidic matrices was evaluated as an initial proof of concept. In one experiment, the PC expansion on a pattern of four drop-casted matrix-assisted laser desorption/ionization matrices led to the selection of α-cyano-4-hydroxycinnamic (CHCA) as the optimal candidate for cationic PC detection. The ion signal is increased by at least three orders of magnitude when PC was expanded using 10 keV Ar3000+ and Ar5000+ on a sublimated layer of CHCA. Finally, the expansion of the gray matter of a mouse on different materials (Si, Au-coated Si, CHCA, and polyethylene) was achieved with varying degrees of success, demonstrating the potential of the method to further analyze complex and fragile biological assemblies.
Collapse
Affiliation(s)
- Benjamin Tomasetti
- Institute of Condensed Matter and Nanosciences, Université catholique de Louvain, 1348 Louvain-la-Neuve, Belgium
| | - Clément Lauzin
- Institute of Condensed Matter and Nanosciences, Université catholique de Louvain, 1348 Louvain-la-Neuve, Belgium
| | - Arnaud Delcorte
- Institute of Condensed Matter and Nanosciences, Université catholique de Louvain, 1348 Louvain-la-Neuve, Belgium
| |
Collapse
|
6
|
Shanmugaraj N, Rutten T, Svatoš A, Schnurbusch T, Mock HP. Fast and Reproducible Matrix Deposition for MALDI Mass Spectrometry Imaging with Improved Glass Sublimation Setup. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:513-517. [PMID: 36735868 DOI: 10.1021/jasms.2c00301] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Sublimation is one of the preferred methods of choice for matrix deposition in high spatial resolution MALDI mass spectrometry imaging (MALDI-MSI) experiments. However, reproducibility and time are the major concerns for this setup. Here we present a lab-made glass sublimator with significant improvements in fine control of the vacuum with real-time monitoring and a rapid sublimation process of only 22 min. This method yielded reproducible homogeneous matrix crystals of <1 μm on the sample surface. MALDI-MSI was performed in tissue sections of barley inflorescence meristems at 15 μm spatial resolution, thus demonstrating its efficiency. Overall, we believe these simple yet effective new modifications can be easily adapted to the standard glass sublimation devices to achieve highly reproducible matrix deposition for high spatial resolution MALDI-MSI.
Collapse
Affiliation(s)
- Nandhakumar Shanmugaraj
- Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Corrensstraße 3, OT Gatersleben, 06466, Seeland, Germany
| | - Twan Rutten
- Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Corrensstraße 3, OT Gatersleben, 06466, Seeland, Germany
| | - Aleš Svatoš
- Max Planck Institute for Chemical Ecology, Hans-Knöll-Straße 8, 07745, Jena, Germany
| | - Thorsten Schnurbusch
- Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Corrensstraße 3, OT Gatersleben, 06466, Seeland, Germany
- Institute of Agricultural and Nutritional Sciences, Faculty of Natural Sciences III, Martin Luther University Halle-Wittenberg, Universitätsplatz 10, 06108 Halle (Saale), Germany
| | - Hans-Peter Mock
- Leibniz Institute of Plant Genetics and Crop Plant Research (IPK), Corrensstraße 3, OT Gatersleben, 06466, Seeland, Germany
| |
Collapse
|
7
|
Pohkrel Y, Adolphs T, Peterson RE, Allebrod U, Ravoo BJ, Arlinghaus HF, Tyler BJ. Influence of Matrix p Ka on Molecular Ion Formation in Matrix-Enhanced Secondary-Ion Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:218-226. [PMID: 36565282 DOI: 10.1021/jasms.2c00261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is one of the most important techniques for chemical imaging of nanomaterials and biological samples with high lateral resolution. However, low ionization efficiency limits the detection of many molecules at low concentrations or in very small volumes. One promising approach to increasing the sensitivity of the technique is by the addition of a matrix that promotes ionization and desorption of important analyte molecules. This approach is known as matrix-enhanced secondary-ion mass spectrometry (ME-SIMS). We have investigated the effect of matrix acidity on molecular ion formation in three different biomolecules. A series of cinnamic acid based matrixes that vary in acidity was employed to systematically investigate the influence of matrix acidity on analyte ion formation. The positive ion signal for all three biomolecules showed a strong increase for more acidic matrixes. The most acidic matrix was then vapor-deposited onto mouse brain sections. This led to significant enhancement of lipid signals from the brain. This work indicates that proton donation plays an important role in the formation of molecular ions in ME-SIMS.
Collapse
Affiliation(s)
- Yogesh Pohkrel
- Physikalisches Institut and Center for Soft Nanoscience, University of Münster, Wilhelm-Klemm-Straße 10, 48149Münster, Germany
| | - Thorsten Adolphs
- Physikalisches Institut and Center for Soft Nanoscience, University of Münster, Wilhelm-Klemm-Straße 10, 48149Münster, Germany
| | - Richard E Peterson
- Physikalisches Institut and Center for Soft Nanoscience, University of Münster, Wilhelm-Klemm-Straße 10, 48149Münster, Germany
| | - Ute Allebrod
- Organic Chemistry Institute and Center for Nanotechnology (CeNTech), Westfälische Wilhelms-Universität Münster, Corrensstrasse 36, 48149Münster, Germany
| | - Bart Jan Ravoo
- Organic Chemistry Institute and Center for Nanotechnology (CeNTech), Westfälische Wilhelms-Universität Münster, Corrensstrasse 36, 48149Münster, Germany
| | - Heinrich F Arlinghaus
- Physikalisches Institut and Center for Soft Nanoscience, University of Münster, Wilhelm-Klemm-Straße 10, 48149Münster, Germany
| | - Bonnie J Tyler
- Physikalisches Institut and Center for Soft Nanoscience, University of Münster, Wilhelm-Klemm-Straße 10, 48149Münster, Germany
| |
Collapse
|
8
|
Harvey DJ. Analysis of carbohydrates and glycoconjugates by matrix-assisted laser desorption/ionization mass spectrometry: An update for 2017-2018. MASS SPECTROMETRY REVIEWS 2023; 42:227-431. [PMID: 34719822 DOI: 10.1002/mas.21721] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Revised: 07/26/2021] [Accepted: 07/26/2021] [Indexed: 06/13/2023]
Abstract
This review is the tenth update of the original article published in 1999 on the application of matrix-assisted laser desorption/ionization mass spectrometry (MALDI) mass spectrometry to the analysis of carbohydrates and glycoconjugates and brings coverage of the literature to the end of 2018. Also included are papers that describe methods appropriate to glycan and glycoprotein analysis by MALDI, such as sample preparation techniques, even though the ionization method is not MALDI. Topics covered in the first part of the review include general aspects such as theory of the MALDI process, new methods, matrices, derivatization, MALDI imaging, fragmentation and the use of arrays. The second part of the review is devoted to applications to various structural types such as oligo- and poly-saccharides, glycoproteins, glycolipids, glycosides, and biopharmaceuticals. Most of the applications are presented in tabular form. The third part of the review covers medical and industrial applications of the technique, studies of enzyme reactions, and applications to chemical synthesis. The reported work shows increasing use of combined new techniques such as ion mobility and highlights the impact that MALDI imaging is having across a range of diciplines. MALDI is still an ideal technique for carbohydrate analysis and advancements in the technique and the range of applications continue steady progress.
Collapse
Affiliation(s)
- David J Harvey
- Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford, UK
| |
Collapse
|
9
|
Nezhad ZS, Salazar JP, Pryce RS, Munter LM, Chaurand P. Absolute quantification of cholesterol from thin tissue sections by silver-assisted laser desorption ionization mass spectrometry imaging. Anal Bioanal Chem 2022; 414:6947-6954. [PMID: 35953724 DOI: 10.1007/s00216-022-04262-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 07/29/2022] [Accepted: 08/02/2022] [Indexed: 11/25/2022]
Abstract
Cholesterol is essential to all animal life, and its dysregulation is observed in many diseases. For some of these, the precise determination of cholesterol's histological location and absolute abundance at cellular length scales within tissue samples would open the door to a more fundamental understanding of the role of cholesterol in disease onset and progression. We have developed a fast and simple method for absolute quantification of cholesterol within brain samples based on the sensitive detection and mapping of cholesterol by silver-assisted laser desorption ionization mass spectrometry imaging (AgLDI MSI) from thin tissue sections. Reproducible calibration curves were generated by depositing a range of cholesterol-D7 concentrations on brain homogenate tissue sections combined with the homogeneous spray deposition of a non-animal steroid reference standard detectable by AgLDI MSI to minimize experimental variability. Results obtained from serial brain sections gave consistent cholesterol quantitative values in very good agreement with those obtained with other mass spectrometry-based methods.
Collapse
Affiliation(s)
- Zari Saadati Nezhad
- Department of Chemistry, Université de Montréal, C.P. 6128, succursale Centre-ville, Montréal, Québec, H3C 3J7, Canada
| | - Juan Pablo Salazar
- Department of Chemistry, Université de Montréal, C.P. 6128, succursale Centre-ville, Montréal, Québec, H3C 3J7, Canada
| | - Rachel S Pryce
- Department of Chemistry, Université de Montréal, C.P. 6128, succursale Centre-ville, Montréal, Québec, H3C 3J7, Canada
| | - Lisa M Munter
- Dept of Pharmacology & Therapeutics, McGill University, Montreal, Quebec, Canada
| | - Pierre Chaurand
- Department of Chemistry, Université de Montréal, C.P. 6128, succursale Centre-ville, Montréal, Québec, H3C 3J7, Canada.
| |
Collapse
|
10
|
Steven RT, Niehaus M, Taylor AJ, Nasif A, Elia E, Goodwin RJA, Takats Z, Bunch J. Atmospheric-Pressure Infrared Laser-Ablation Plasma-Postionization Mass Spectrometry Imaging of Formalin-Fixed Paraffin-Embedded (FFPE) and Fresh-Frozen Tissue Sections with No Sample Preparation. Anal Chem 2022; 94:9970-9974. [PMID: 35798333 PMCID: PMC9310026 DOI: 10.1021/acs.analchem.2c00690] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
![]()
Mass spectrometry
imaging (MSI) encompasses a powerful suit of
techniques which provide spatially resolved atomic and molecular information
from almost any sample type. MSI is now widely used in preclinical
research to provide insight into metabolic phenotypes of disease.
Typically, fresh-frozen tissue preparations are considered optimal
for biological MSI and other traditional preservation methods such
as formalin fixation, alone or with paraffin embedding (FFPE), are
considered less optimal or even incompatible. Due to the prevalence
of FFPE tissue storage, particularly for rare and therefore high-value
tissue samples, there is substantial motivation for optimizing MSI
methods for analysis of FFPE tissue. Here, we present a novel modality,
atmospheric-pressure infrared laser-ablation plasma postionization
(AP-IR-LA-PPI), with the first proof-of-concept examples of MSI for
FFPE and fresh-frozen tissues, with no post-sectioning sample preparation.
We present ion images from FFPE and fresh tissues in positive and
negative ion modes. Molecular annotations (via the Metaspace annotation
engine) and on-tissue MS/MS provide additional confidence that the
detected ions arise from a broad range of metabolite and lipid classes
from both FFPE and fresh-frozen tissues.
Collapse
Affiliation(s)
- Rory T Steven
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom
| | - Marcel Niehaus
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom
| | - Adam J Taylor
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom
| | - Ammar Nasif
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom
| | - Efstathios Elia
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom
| | - Richard J A Goodwin
- Imaging and Data Analytics, Clinical Pharmacology and Safety Sciences, BioPharmaceuticals R&D, AstraZeneca, Cambridge CB2 0WG, United Kingdom.,Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8TA, United Kingdom
| | - Zoltan Takats
- Faculty of Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College London, South Kensington Campus, London SW7 2AZ, United Kingdom.,Biological Mass Spectrometry, Rosalind Franklin Institute, Harwell Campus, Didcot OX11 0QS, United Kingdom
| | - Josephine Bunch
- National Centre of Excellence in Mass Spectrometry Imaging, National Physical Laboratory, Teddington TW12 0WL, United Kingdom.,Faculty of Medicine, Department of Metabolism, Digestion and Reproduction, Imperial College London, South Kensington Campus, London SW7 2AZ, United Kingdom.,Biological Mass Spectrometry, Rosalind Franklin Institute, Harwell Campus, Didcot OX11 0QS, United Kingdom
| |
Collapse
|
11
|
Zhao C, Cai Z. Three-dimensional quantitative mass spectrometry imaging in complex system: From subcellular to whole organism. MASS SPECTROMETRY REVIEWS 2022; 41:469-487. [PMID: 33300181 DOI: 10.1002/mas.21674] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 10/13/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
Mass spectrometry imaging (MSI) has been applied for label-free three-dimensional (3D) imaging from position array across the whole organism, which provides high-dimensional quantitative data of inorganic or organic compounds that may play an important role in the regulation of cellular signaling, including metals, metabolites, lipids, drugs, peptides, and proteins. While MSI is suitable for investigation of the spatial distribution of molecules, it has a limitation with visualization and quantification of multiple molecules. 3D-MSI, however, can be applied toward exploring metabolic pathway as well as the interactions of lipid-protein, protein-protein, and metal-protein in complex systems from subcellular to the whole organism through an untargeted methodology. In this review, we highlight the methods and applications of MS-based 3D imaging to address the complexity of molecular interaction from nano- to micrometer lateral resolution, with particular focus on: (a) common and hybrid 3D-MSI techniques; (b) quantitative MSI methodology, including the methods using a stable isotope labeling internal standard (SILIS) and SILIS-free approaches with tissue extinction coefficient or virtual calibration; (c) reconstruction of the 3D organ; (d) application of 3D-MSI for biomarker screening and environmental toxicological research. 3D-MSI quantitative analysis provides accurate spatial information and quantitative variation of biomolecules, which may be valuable for the exploration of the molecular mechanism of the disease progresses and toxicological assessment of environmental pollutants in the whole organism. Additionally, we also discuss the challenges and perspectives on the future of 3D quantitative MSI.
Collapse
Affiliation(s)
- Chao Zhao
- State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong SAR, China
- Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zongwei Cai
- State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong SAR, China
| |
Collapse
|
12
|
Noun M, Akoumeh R, Abbas I. Cell and Tissue Imaging by TOF-SIMS and MALDI-TOF: An Overview for Biological and Pharmaceutical Analysis. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2022; 28:1-26. [PMID: 34809729 DOI: 10.1017/s1431927621013593] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The potential of mass spectrometry imaging (MSI) has been demonstrated in cell and tissue research since 1970. MSI can reveal the spatial distribution of a wide range of atomic and molecular ions detected from biological sample surfaces, it is a powerful and valuable technique used to monitor and detect diverse chemical and biological compounds, such as drugs, lipids, proteins, and DNA. MSI techniques, notably matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) and time of flight secondary ion mass spectrometry (TOF-SIMS), witnessed a dramatic upsurge in studying and investigating biological samples especially, cells and tissue sections. This advancement is attributed to the submicron lateral resolution, the high sensitivity, the good precision, and the accurate chemical specificity, which make these techniques suitable for decoding and understanding complex mechanisms of certain diseases, as well as monitoring the spatial distribution of specific elements, and compounds. While the application of both techniques for the analysis of cells and tissues is thoroughly discussed, a briefing of MALDI-TOF and TOF-SIMS basis and the adequate sampling before analysis are briefly covered. The importance of MALDI-TOF and TOF-SIMS as diagnostic tools and robust analytical techniques in the medicinal, pharmaceutical, and toxicology fields is highlighted through representative published studies.
Collapse
Affiliation(s)
- Manale Noun
- Lebanese Atomic Energy Commission - NCSR, Beirut, Lebanon
| | - Rayane Akoumeh
- Lebanese Atomic Energy Commission - NCSR, Beirut, Lebanon
| | - Imane Abbas
- Lebanese Atomic Energy Commission - NCSR, Beirut, Lebanon
| |
Collapse
|
13
|
Li H, Wu R, Hu Q, Chen X, Dominic Chan TW. A Matrix Sublimation Device with an Integrated Solvent Nebulizer for MALDI-MSI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:11-16. [PMID: 34939792 DOI: 10.1021/jasms.1c00335] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The current matrix deposition methods in MALDI-mass spectrometry imaging (MALDI-MSI) face technical problems related to the inhomogeneous distribution of crystals and the low analyte extraction and cocrystallization efficiency. In this work, an integrated matrix sublimation device with synchronous solvent nebulization was developed for MALDI-MSI. Droplets of solvents were directly introduced into the chamber of the sublimator by using a miniaturized ultrasonic nebulizer unit. The synchronous and asynchronous working modes of solvent nebulization and matrix sublimation were systematically investigated. Imaging of both protein and small metabolite distributions in mouse brain tissue sections was successfully performed using the developed matrix deposition device. The sensitivity and quality of the images were clearly improved in synchronous mode compared with those of the conventional spray and sublimation methods. These results demonstrate that the integrated device with both solvent nebulization and matrix sublimation is a useful tool in MALDI-MSI applications.
Collapse
Affiliation(s)
- Huizhi Li
- Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Shandong Analysis and Test Centre, Qilu University of Technology (Shandong Academy of Sciences), 19th Keyuan Road, Jinan, Shandong 250014, P.R. China
| | - Ri Wu
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, P.R. China
| | - Qiongzheng Hu
- Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Shandong Analysis and Test Centre, Qilu University of Technology (Shandong Academy of Sciences), 19th Keyuan Road, Jinan, Shandong 250014, P.R. China
| | - Xiangfeng Chen
- Key Laboratory for Applied Technology of Sophisticated Analytical Instruments of Shandong Province, Shandong Analysis and Test Centre, Qilu University of Technology (Shandong Academy of Sciences), 19th Keyuan Road, Jinan, Shandong 250014, P.R. China
| | - T-W Dominic Chan
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR, P.R. China
| |
Collapse
|
14
|
Engel KM, Prabutzki P, Leopold J, Nimptsch A, Lemmnitzer K, Vos DRN, Hopf C, Schiller J. A new update of MALDI-TOF mass spectrometry in lipid research. Prog Lipid Res 2022; 86:101145. [PMID: 34995672 DOI: 10.1016/j.plipres.2021.101145] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 12/06/2021] [Accepted: 12/29/2021] [Indexed: 01/06/2023]
Abstract
Matrix-assisted laser desorption and ionization (MALDI) mass spectrometry (MS) is an indispensable tool in modern lipid research since it is fast, sensitive, tolerates sample impurities and provides spectra without major analyte fragmentation. We will discuss some methodological aspects, the related ion-forming processes and the MALDI MS characteristics of the different lipid classes (with the focus on glycerophospholipids) and the progress, which was achieved during the last ten years. Particular attention will be given to quantitative aspects of MALDI MS since this is widely considered as the most serious drawback of the method. Although the detailed role of the matrix is not yet completely understood, it will be explicitly shown that the careful choice of the matrix is crucial (besides the careful evaluation of the positive and negative ion mass spectra) in order to be able to detect all lipid classes of interest. Two developments will be highlighted: spatially resolved Imaging MS is nowadays well established and the distribution of lipids in tissues merits increasing interest because lipids are readily detectable and represent ubiquitous compounds. It will also be shown that a combination of MALDI MS with thin-layer chromatography (TLC) enables a fast spatially resolved screening of an entire TLC plate which makes the method competitive with LC/MS.
Collapse
Affiliation(s)
- Kathrin M Engel
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany
| | - Patricia Prabutzki
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany
| | - Jenny Leopold
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany
| | - Ariane Nimptsch
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany
| | - Katharina Lemmnitzer
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany
| | - D R Naomi Vos
- Center for Biomedical Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Strasse 10, D-68163 Mannheim, Germany
| | - Carsten Hopf
- Center for Biomedical Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Strasse 10, D-68163 Mannheim, Germany
| | - Jürgen Schiller
- Leipzig University, Faculty of Medicine, Institute for Medical Physics and Biophysics, Härtelstraße 16-18, D-04107, Germany.
| |
Collapse
|
15
|
Bouvier C, Van Nuffel S, Walter P, Brunelle A. Time-of-flight secondary ion mass spectrometry imaging in cultural heritage: A focus on old paintings. JOURNAL OF MASS SPECTROMETRY : JMS 2022; 57:e4803. [PMID: 34997666 DOI: 10.1002/jms.4803] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 12/06/2021] [Accepted: 12/13/2021] [Indexed: 06/14/2023]
Abstract
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging is a surface analysis technique that identifies and spatially resolves the chemical composition of a sample with a lateral resolution of less than 1 μm. Depth analyses can also be performed over thicknesses of several microns. In the case of a painting cross section, for example, TOF-SIMS can identify the organic composition, by detecting molecular ions and fragments of binders, as well as the mineral composition of most of the pigments. Importantly, the technique is almost not destructive and is therefore increasingly used in cultural heritage research such as the analysis of painting samples, especially old paintings. In this review, state of the art of TOF-SIMS analysis methods will be described with a particular focus on tuning the instruments for the analysis of painting cross sections and with several examples from the literature showing the added value of this technique when studying cultural heritage samples.
Collapse
Affiliation(s)
- Caroline Bouvier
- Sorbonne Université, CNRS, Laboratoire d'Archéologie Moléculaire et Structurale (LAMS), Paris, France
| | - Sebastiaan Van Nuffel
- M4I, Faculty of Science and Engineering, Maastricht University, Maastricht, The Netherlands
| | - Philippe Walter
- Sorbonne Université, CNRS, Laboratoire d'Archéologie Moléculaire et Structurale (LAMS), Paris, France
| | - Alain Brunelle
- Sorbonne Université, CNRS, Laboratoire d'Archéologie Moléculaire et Structurale (LAMS), Paris, France
| |
Collapse
|
16
|
Moshkunov K, Tomasetti B, Daphnis T, Delmez V, Vanvarenberg K, Préat V, Lorenz M, Quanico J, Baggerman G, Lemiere F, Dupont C, Delcorte A. Improvement of biomolecular analysis in thin films using in situ matrix enhanced secondary ion mass spectrometry. Analyst 2021; 146:6506-6519. [PMID: 34570146 DOI: 10.1039/d1an00727k] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Sensitivity to molecular ions remains a limiting factor for high resolution imaging mass spectrometry of organic and biological materials. Here, we investigate a variant of matrix-enhanced secondary ion mass spectrometry in which the transfer of matrix molecules to the analyte sample is carried out in situ (in situ ME-SIMS). This approach is therefore compatible with both 2D and 3D imaging by SIMS. In this exploratory study, nanoscale matrix layers were sputter-transferred inside our time-of-flight (ToF)-SIMS to a series of thin films of biomolecules (proteins, sugars, lipids) adsorbed on silicon, and the resulting layers were analyzed and depth-profiled. For this purpose, matrix molecules were desorbed from a coated target (obtained by drop-casting or sublimation) using 10 keV Ar3000+ ion beam sputtering, followed by redeposition on a collector carrying the sample to be analyzed. After evaluating the quality of the transfer of six different matrices on bare Si collectors, α-cyano-4-hydroxycinnamic acid (CHCA) was selected for further experiments. The mass spectra and depth profiles obtained from the organic layer prior to and after the sputter-transfer of CHCA were compared, along with those obtained from regular ME-SIMS samples (dried droplets) and, finally, with MALDI data for the same matrix-analyte combinations. Signal amplification factors were calculated by dividing the integrated molecular intensities obtained with or without matrix transfer. While the amplification factors are between 0.5 and 2 for molecules already detected with high intensities in SIMS, such as cholesterol or human angiotensin, other compounds show very large integrated signal amplification, even above two orders of magnitude. This is the case for D-glucose and cardiolipin, for which the molecular ion intensity is low (or very low) under normal SIMS analysis conditions. For such low ionization probability compounds, the beneficial effect of the matrix is unquestionable. Test experiments on mouse brain tissue sections also indicate signal enhancement with the matrix, especially for high mass lipid ions.
Collapse
Affiliation(s)
- Konstantin Moshkunov
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| | - Benjamin Tomasetti
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| | - Thomas Daphnis
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| | - Vincent Delmez
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| | - Kevin Vanvarenberg
- Louvain Drug Research Institute, Université catholique de Louvain, Avenue Mounier 73, 1200 Woluwe-Saint-Lambert, Belgium
| | - Véronique Préat
- Louvain Drug Research Institute, Université catholique de Louvain, Avenue Mounier 73, 1200 Woluwe-Saint-Lambert, Belgium
| | - Matthias Lorenz
- National Physical Laboratory, Hampton Road, Teddington TW11 0LW, UK.,Present address: PerkinElmer Inc., 6-501 Rowntree Dairy Rd, Woodbridge, ON L4L 8H1, Canada
| | - Jusal Quanico
- Centre for Proteomics (CFP), University of Antwerp, Groenenborgerlaan 171, B2020 Antwerp, Belgium
| | - Geert Baggerman
- Centre for Proteomics (CFP), University of Antwerp, Groenenborgerlaan 171, B2020 Antwerp, Belgium.,Flemish Institute for Technological Research (VITO), Boeretang 200, B-2400 Mol, Belgium
| | - Filip Lemiere
- Centre for Proteomics (CFP), University of Antwerp, Groenenborgerlaan 171, B2020 Antwerp, Belgium.,Department of Chemistry, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
| | - Christine Dupont
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| | - Arnaud Delcorte
- Institute of Condensed Matter and Nanoscience, Université catholique de Louvain, 1 Place Louis Pasteur, 1348 Louvain-la-Neuve, Belgium.
| |
Collapse
|
17
|
Nambiar S, Kahn N, Gummer JPA. Matrix-Assisted Laser Desorption Ionization Mass Spectrometry Imaging by Freeze-Spot Deposition of the Matrix. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1829-1836. [PMID: 34047188 DOI: 10.1021/jasms.1c00063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Imaging mass spectrometry has emerged as a powerful metabolite measurement approach to capture the spatial dimension of metabolite distribution in a biological sample. In matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI), deposition of the chemical-matrix onto the sample serves to simultaneously extract biomolecules to the sample surface and concurrently render the sample amenable to MALDI. However, matrix application may mobilize sample metabolites and will dictate the efficiency of matrix crystallization, together limiting the lateral resolution which may be optimally achieved by MSI. Here, we describe a matrix application technique, herein referred to as the "freeze-spot" method, conceived as a low-cost preparative approach requiring minimal amounts of chemical matrix while maintaining the spatial dimension of sample metabolites for MALDI-MSI. Matrix deposition was achieved by pipette spot application of the matrix-solubilized within a solvent solution with a freezing point above that of a chilled sample stage to which the sample section is mounted. The matrix solution freezes on contact with the sample and the solvent is removed by sublimation, leaving a fine crystalline matrix on the sample surface. Freeze-spotting is quick to perform, found particularly useful for MALDI-MSI of small sample sections, and well suited to efficient and cost-effective method development pipelines, while capable of maintaining the lateral resolution required by MSI.
Collapse
Affiliation(s)
- Shabarinath Nambiar
- School of Veterinary and Life Sciences, Murdoch University, Murdoch, Western Australia 6150, Australia
| | - Nusrat Kahn
- School of Environmental Science, Murdoch University, Murdoch, Western Australia 6150, Australia
| | - Joel P A Gummer
- School of Science, Edith Cowan University, Joondalup, Western Australia 6027, Australia
- ChemCentre, Bentley, Western Australia 6102, Australia
| |
Collapse
|
18
|
Xie H, Wu R, Hung YLW, Chen X, Chan TWD. Development of a Matrix Sublimation Device with Controllable Crystallization Temperature for MALDI Mass Spectrometry Imaging. Anal Chem 2021; 93:6342-6347. [PMID: 33852267 DOI: 10.1021/acs.analchem.1c00260] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The size and distribution of matrix crystals deposited on the surface of a tissue section play a key role in the performance of MALDI mass spectrometry imaging (MALDI-MSI). In this study, uniform distribution and a restricted size of matrix crystals were achieved via a homemade matrix sublimation device with controllable crystallization temperature. The crystallization temperature was stably controlled at a subzero temperature, and homogeneous matrix crystals with diameters <0.2 μm were generated on the sample surface. Typical MALDI-MSI experiments of endogenous and exogenous components in the tissues of strawberries, kidneys, and mussels were conducted to examine the performance of the sublimator. Good reproducibility of MALDI-MSI was achieved, and the quality of ion images was significantly improved. These results demonstrate that the developed sublimator should have potential in matrix deposition for further high resolution MALDI-MSI application.
Collapse
Affiliation(s)
- Hanyi Xie
- School of Pharmaceutical sciences, Qilu University of Technology (Shandong Academy of Sciences), 19th Keyuan Road, Jinan, Shandong 250014, People's Republic of China
| | - Ri Wu
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, People's Republic of China
| | - Y L Winnie Hung
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, People's Republic of China
| | - Xiangfeng Chen
- School of Pharmaceutical sciences, Qilu University of Technology (Shandong Academy of Sciences), 19th Keyuan Road, Jinan, Shandong 250014, People's Republic of China
| | - T-W Dominic Chan
- Department of Chemistry, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong Special Administrative Region, People's Republic of China
| |
Collapse
|
19
|
Na HK, Shon HK, Son HY, Jang E, Joh S, Huh YM, Castner DG, Lee TG. Utilization of chromogenic enzyme substrates for signal amplification in multiplexed detection of biomolecules using surface mass spectrometry. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 332:129452. [PMID: 33519092 PMCID: PMC7845929 DOI: 10.1016/j.snb.2021.129452] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
MicroRNAs (miRNAs) are important post-transcriptional gene regulators and can serve as potential biomarkers for many diseases. Most of the current miRNA detection techniques require purification from biological samples, amplification, labeling, or tagging, which makes quantitative analysis of clinically relevant samples challenging. Here we present a new strategy for the detection of miRNAs with uniformity over a large area based on signal amplification using enzymatic reactions and measurements using time-of-flight secondary ion mass spectrometry (ToF-SIMS), a sensitive surface analysis tool. This technique has high sequence specificity through hybridization with a hairpin DNA probe and allows the identification of single-base mismatches that are difficult to distinguish by conventional mass spectrometry. We successfully detected target miRNAs in biological samples without purification, amplification, or labeling of target molecules. In addition, by adopting a well-known chromogenic enzymatic reaction from the field of biotechnology, we extended the use of enzyme-amplified signal enhancement ToF (EASE-ToF) to protein detection. Our strategy has advantages with respect to scope, quantification, and throughput over the currently available methods, and is amenable to multiplexing based on the outstanding molecular specificity of mass spectrometry (MS). Therefore, our technique not only has the potential for use in clinical diagnosis, but also provides evidence that MS can serve as a useful readout for biosensing to perform multiplexed analysis extending beyond the limitations of existing technology.
Collapse
Affiliation(s)
- Hee-Kyung Na
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea
| | - Hyun Kyong Shon
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea
| | - Hye Young Son
- Department of Radiology, College of Medicine, Yonsei University, Seoul 03722, Korea
| | - Eunji Jang
- Department of Radiology, College of Medicine, Yonsei University, Seoul 03722, Korea
| | - Sunho Joh
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea
- Department of Nano Science, University of Science and Technology (UST), Daejeon 34113, Korea
| | - Yong-Min Huh
- Department of Radiology, College of Medicine, Yonsei University, Seoul 03722, Korea
| | - David G. Castner
- National ESCA and Surface Analysis Center for Biomedical Problems, Departments of Bioengineering and Chemical Engineering, University of Washington, Seattle, WA 98195-1653, USA
| | - Tae Geol Lee
- Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science (KRISS), Daejeon 34113, Korea
- Department of Nano Science, University of Science and Technology (UST), Daejeon 34113, Korea
| |
Collapse
|
20
|
Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification. Metabolites 2021; 11:metabo11040200. [PMID: 33801673 PMCID: PMC8065410 DOI: 10.3390/metabo11040200] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 03/23/2021] [Accepted: 03/25/2021] [Indexed: 12/13/2022] Open
Abstract
Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.
Collapse
|
21
|
Garate J, Maimó-Barceló A, Bestard-Escalas J, Fernández R, Pérez-Romero K, Martínez MA, Payeras MA, Lopez DH, Fernández JA, Barceló-Coblijn G. A Drastic Shift in Lipid Adducts in Colon Cancer Detected by MALDI-IMS Exposes Alterations in Specific K + Channels. Cancers (Basel) 2021; 13:cancers13061350. [PMID: 33802791 PMCID: PMC8061771 DOI: 10.3390/cancers13061350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 03/04/2021] [Accepted: 03/10/2021] [Indexed: 01/12/2023] Open
Abstract
Even though colorectal cancer (CRC) is one of the most preventable cancers, it is one of the deadliest, and recent data show that the incidence in people <50 years has unexpectedly increased. While new techniques for CRC molecular classification are emerging, no molecular feature is as yet firmly associated with prognosis. Imaging mass spectrometry (IMS) lipidomic analyses have demonstrated the specificity of the lipid fingerprint in differentiating pathological from healthy tissues. During IMS lipidomic analysis, the formation of ionic adducts is common. Of particular interest is the [Na+]/[K+] adduct ratio, which already functions as a biomarker for homeostatic alterations. Herein, we show a drastic shift of the [Na+]/[K+] adduct ratio in adenomatous colon mucosa compared to healthy mucosa, suggesting a robust increase in K+ levels. Interrogating public databases, a strong association was found between poor diagnosis and voltage-gated potassium channel subunit beta-2 (KCNAB2) overexpression. We found this overexpression in three CRC molecular subtypes defined by the CRC Subtyping Consortium, making KCNAB2 an interesting pharmacological target. Consistently, its pharmacological inhibition resulted in a dramatic halt in commercial CRC cell proliferation. Identification of potential pharmacologic targets using lipid adduct information emphasizes the great potential of IMS lipidomic techniques in the clinical field.
Collapse
Affiliation(s)
- Jone Garate
- Department of Physical Chemistry, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain; (J.G.); (R.F.); (J.A.F.)
| | - Albert Maimó-Barceló
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Research Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - Joan Bestard-Escalas
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Research Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - Roberto Fernández
- Department of Physical Chemistry, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain; (J.G.); (R.F.); (J.A.F.)
- Research Department, IMG Pharma Biotech S.L., BIC Bizkaia (612), 48160 Derio, Spain
| | - Karim Pérez-Romero
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Research Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - Marco A. Martínez
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Pathology Anatomy Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - Mª Antònia Payeras
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Gastroenterology Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - Daniel H. Lopez
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Research Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
| | - José Andrés Fernández
- Department of Physical Chemistry, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain; (J.G.); (R.F.); (J.A.F.)
| | - Gwendolyn Barceló-Coblijn
- Institut d’Investigació Sanitària Illes Balears (IdISBa, Health Research Institute of the Balearic Islands), 07120 Palma, Spain; (A.M.-B.); (J.B.-E.); (K.P.-R.); (M.A.M.); (M.A.P.); (D.H.L.)
- Research Unit, Hospital Universitari Son Espases, 07120 Palma, Spain
- Correspondence: ; Tel.: +34-871-205-000 (ext. 66300)
| |
Collapse
|
22
|
Bien T, Bessler S, Dreisewerd K, Soltwisch J. Transmission-Mode MALDI Mass Spectrometry Imaging of Single Cells: Optimizing Sample Preparation Protocols. Anal Chem 2021; 93:4513-4520. [PMID: 33646746 DOI: 10.1021/acs.analchem.0c04905] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) makes it possible to simultaneously visualize the spatial distribution of dozens to hundreds of different biomolecules (e.g., phospho- and glycolipids) in tissue sections and in cell cultures. The implementation of novel desorption and (post-)ionization techniques has recently pushed the pixel size of this imaging technique to the low micrometer scale and below and thus to a cellular and potentially sub-cellular level. However, to fully exploit this potential for cell biology and biomedicine, sample preparation becomes highly demanding. Here, we investigated the effect of several key parameters on the quality of the sample preparation and achievable spatial resolution, that include the washing, drying, chemical fixation, and matrix coating steps. The incubation of cells with formalin for about 5 min in combination with isotonic washing and mild drying produced a robust protocol that largely preserved not only cell morphologies, but also the molecular integrities of amine group-containing cell membrane phospholipids (phosphatidylethanolamines and -serines). A disadvantage of the chemical fixation is an increased permeabilization of cell membranes, resulting in leakage of cytosolic compounds. We demonstrate the pros and cons of the protocols with four model cell lines, cultured directly on indium tin oxide (ITO)-coated glass slides. Transmission (t-)mode MALDI-2-MSI enabled on a Q Exactive plus Orbitrap mass spectrometer was used to analyze the cultures at a pixel size of 2 μm. Phase contrast light microscopy and scanning electron microscopy were used as complementary methods. The protocols described could prove to be an important contribution to the advancement of single-cell MALDI imaging, especially for the characterization of cell-to-cell heterogeneities at a molecular level.
Collapse
Affiliation(s)
- Tanja Bien
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149 Münster, Germany.,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149 Münster, Germany
| | - Sebastian Bessler
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149 Münster, Germany
| | - Klaus Dreisewerd
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149 Münster, Germany.,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149 Münster, Germany
| | - Jens Soltwisch
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149 Münster, Germany.,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149 Münster, Germany
| |
Collapse
|
23
|
Li HW, Hu Z, Chen X, Ren J, Cui H, Zhang M, Chen L, Hua X, Song J, Long YT. Investigation of Lipid Metabolism in Dynamic Progression of Coronary Artery Atherosclerosis of Humans by Time-of-Flight Secondary Ion Mass Spectrometry. Anal Chem 2021; 93:3839-3847. [PMID: 33587603 DOI: 10.1021/acs.analchem.0c04367] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Alterations in lipid metabolites in coronary artery tissues are phenotypic changes in the progression of atherosclerosis (AS). A full picture of the spatiotemporal distribution of lipid metabolites in coronary AS is needed for a deeper understanding of its pathology and the identification of potential biomarkers of disease progression. In this work, the changes in species, quantity, and distribution of lipid metabolites at different stages of AS, which were standardized by the disease areas, were analyzed through the high spatial resolution- and high sensitivity-time-of-flight secondary ion mass spectrometry (ToF-SIMS) under delayed extraction mode. Based on high lateral resolution imaging, we further analyzed the ToF-SIMS data extracted from the subregions of AS lesion tissues at different disease progression stages by semiquantitative comparison, clustering analysis (t-stochastic neighbor embedding and HCA), and KEGG enrichment. Thus, a much-detailed description of lipids' features in coronary AS was achieved. We constructed a ToF-SIMS mass spectrometry database of coronary AS lipids. 40 specific lipid metabolites with distinctive patterns between different pathological stages were obtained. Chemical imaging unveiled further details regarding the spatial distribution of lipids. Moreover, linoleic acid and arachidonic acid metabolic pathway were predicted to be critical in AS progression.
Collapse
Affiliation(s)
- Hao-Wen Li
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China.,Institute of Molecular Medicine, Shanghai Key Laboratory for Nucleic Acid Chemistry and Nanomedicine, State Key Laboratory of Oncogenes and Related Genes, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, P. R. China
| | - Zhan Hu
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Xiao Chen
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Jie Ren
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Hao Cui
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Min Zhang
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China
| | - Liang Chen
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Xin Hua
- School of Chemistry and Molecular Engineering, East China University of Science and Technology, Shanghai 200237, P. R. China.,Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Jiangping Song
- State Key Laboratory of Cardiovascular Disease, Fuwai Hospital; National Center for Cardiovascular Disease. Chinese Academy of Medicine Science (CAMS) and Perking Union Medical College (PUMC), 167A Beilishi Road, Xi Cheng District, Beijing 100037, P. R. China
| | - Yi-Tao Long
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China
| |
Collapse
|
24
|
Van Nuffel S, Ang KC, Lin AY, Cheng KC. Chemical Imaging of Retinal Pigment Epithelium in Frozen Sections of Zebrafish Larvae Using ToF-SIMS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:255-261. [PMID: 33112610 DOI: 10.1021/jasms.0c00300] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Variants of the SLC24A5 gene, which encodes a putative potassium-dependent sodium-calcium exchanger (NCKX5) that most likely resides in the melanosome or its precursor, affect pigmentation in both humans and zebrafish (Danio rerio). This finding suggests that genetic variations influencing human skin pigmentation alter melanosome biogenesis via ionic changes. Gaining an understanding of how changes in the ionic environment of organelles impact melanosome morphogenesis and pigmentation will require a spatially resolved way to characterize the chemical environment of melanosomes in pigmented tissue such as retinal pigment epithelium (RPE). The imaging mass spectrometry technique most suited for this type of cell and tissue analysis is time-of-flight secondary ion mass spectrometry (ToF-SIMS) because it is able to detect many biochemical species with high sensitivity and with submicron spatial resolution. Here, we describe chemical imaging of the RPE in frozen-hydrated sections of larval zebrafish using cryo-ToF-SIMS. To facilitate the data interpretation, positive and negative polarity ToF-SIMS image data were transformed into a single hyperspectral data set and analyzed using principal component analysis. The combination of a novel protocol and the use of multivariate data analysis allowed us to discover new marker ions that are attributable to leucodopachrome, a metabolite specific to the biosynthesis of eumelanin. The described methodology may be adapted for the investigation of other classes of molecules in frozen tissues from zebrafish and other organisms.
Collapse
Affiliation(s)
- Sebastiaan Van Nuffel
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Khai C Ang
- The Jake Gittlen Laboratories for Cancer Research, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Division of Experimental Pathology, Department of Pathology, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Penn State Zebrafish Functional Genomics Core, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
| | - Alex Y Lin
- The Jake Gittlen Laboratories for Cancer Research, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Division of Experimental Pathology, Department of Pathology, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Penn State Zebrafish Functional Genomics Core, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
| | - Keith C Cheng
- The Jake Gittlen Laboratories for Cancer Research, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Division of Experimental Pathology, Department of Pathology, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
- Penn State Zebrafish Functional Genomics Core, Penn State College of Medicine, Hershey, Pennsylvania 17033, United States
| |
Collapse
|
25
|
Drake RR, Scott DA, Angel PM. Imaging Mass Spectrometry. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00017-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
26
|
Bien T, Hambleton EA, Dreisewerd K, Soltwisch J. Molecular insights into symbiosis-mapping sterols in a marine flatworm-algae-system using high spatial resolution MALDI-2-MS imaging with ion mobility separation. Anal Bioanal Chem 2020; 413:2767-2777. [PMID: 33274397 PMCID: PMC8007520 DOI: 10.1007/s00216-020-03070-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/27/2020] [Accepted: 11/13/2020] [Indexed: 12/11/2022]
Abstract
Waminoa sp. acoel flatworms hosting Symbiodiniaceae and the related Amphidinium dinoflagellate algae are an interesting model system for symbiosis in marine environments. While the host provides a microhabitat and safety, the algae power the system by photosynthesis and supply the worm with nutrients. Among these nutrients are sterols, including cholesterol and numerous phytosterols. While it is widely accepted that these compounds are produced by the symbiotic dinoflagellates, their transfer to and fate within the sterol-auxotrophic Waminoa worm host as well as their role in its metabolism are unknown. Here we used matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging combined with laser-induced post-ionization and trapped ion mobility spectrometry (MALDI-2-TIMS-MSI) to map the spatial distribution of over 30 different sterol species in sections of the symbiotic system. The use of laser post-ionization crucially increased ion yields and allowed the recording of images with a pixel size of 5 μm. Trapped ion mobility spectrometry (TIMS) helped with the tentative assignment of over 30 sterol species. Correlation with anatomical features of the worm, revealed by host-derived phospholipid signals, and the location of the dinoflagellates, revealed by chlorophyll a signal, disclosed peculiar differences in the distribution of different sterol species (e.g. of cholesterol versus stigmasterol) within the receiving host. These findings point to sterol species-specific roles in the metabolism of Waminoa beyond a mere source of energy. They also underline the value of the MALDI-2-TIMS-MSI method to future research in the spatially resolved analysis of sterols.
Collapse
Affiliation(s)
- Tanja Bien
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149, Münster, Germany.,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149, Münster, Germany
| | - Elizabeth A Hambleton
- Centre for Microbiology and Environmental Systems Science, Division of Microbial Ecology, University of Vienna, Althanstr. 14, 1090, Vienna, Austria
| | - Klaus Dreisewerd
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149, Münster, Germany.,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149, Münster, Germany
| | - Jens Soltwisch
- Institute of Hygiene, University of Münster, Robert-Koch-Str. 41, 48149, Münster, Germany. .,Interdisciplinary Center for Clinical Research (IZKF), University of Münster, Domagkstr. 3, 48149, Münster, Germany.
| |
Collapse
|
27
|
Tuck M, Blanc L, Touti R, Patterson NH, Van Nuffel S, Villette S, Taveau JC, Römpp A, Brunelle A, Lecomte S, Desbenoit N. Multimodal Imaging Based on Vibrational Spectroscopies and Mass Spectrometry Imaging Applied to Biological Tissue: A Multiscale and Multiomics Review. Anal Chem 2020; 93:445-477. [PMID: 33253546 DOI: 10.1021/acs.analchem.0c04595] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Michael Tuck
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Landry Blanc
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Rita Touti
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Nathan Heath Patterson
- Mass Spectrometry Research Center, Department of Biochemistry, Vanderbilt University, Nashville, Tennessee 37232-8575, United States
| | - Sebastiaan Van Nuffel
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Sandrine Villette
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Jean-Christophe Taveau
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Andreas Römpp
- Bioanalytical Sciences and Food Analysis, University of Bayreuth, Universitätsstraße 30, 95440 Bayreuth, Germany
| | - Alain Brunelle
- Laboratoire d'Archéologie Moléculaire et Structurale, LAMS UMR 8220, CNRS, Sorbonne Université, 4 Place Jussieu, 75005 Paris, France
| | - Sophie Lecomte
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| | - Nicolas Desbenoit
- Institut de Chimie & Biologie des Membranes & des Nano-objets, CBMN UMR 5248, CNRS, Université de Bordeaux, 1 Allée Geoffroy Saint-Hilaire, 33600 Pessac, France
| |
Collapse
|
28
|
Fernández-Vega A, Chicano-Gálvez E, Prentice BM, Anderson D, Priego-Capote F, López-Bascón MA, Calderón-Santiago M, Avendaño MS, Guzmán-Ruiz R, Tena-Sempere M, Fernández JA, Caprioli RM, Malagón MM. Optimization of a MALDI-Imaging protocol for studying adipose tissue-associated disorders. Talanta 2020; 219:121184. [PMID: 32887102 DOI: 10.1016/j.talanta.2020.121184] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 05/13/2020] [Accepted: 05/15/2020] [Indexed: 12/13/2022]
Abstract
Matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry (IMS) is increasingly recognized for its potential in the discovery of novel biomarkers directly from tissue sections. However, there are no MALDI IMS studies as yet on the adipose tissue, a lipid-enriched tissue that plays a pivotal role in the development of obesity-associated disorders. Herein, we aimed at developing an optimized method for analyzing adipose tissue lipid composition under both physiological and pathological conditions by MALDI IMS. Our studies showed an exacerbated lipid delocalization from adipose tissue sections when conventional strategies were applied. However, our optimized method using conductive-tape sampling and 2,5-dihydroxybenzoic acid (DHB) as a matrix, preserved the anatomical organization and minimized lipid diffusion from sample sections. This method enabled the identification of a total of 625 down-regulated and 328 up-regulated m/z values in the adipose tissue from a rat model of extreme obesity as compared to lean animals. Combination of MALDI IMS and liquid chromatography (LC)-MS/MS data identified 44 differentially expressed lipid species between lean and obese animals, including phospholipids and sphingomyelins. Among the lipids identified, SM(d18:0_18:2), PE(P-16:0_20:0), and PC(O-16:0_16:1) showed a differential spatial distribution in the adipose tissue of lean vs. obese animals. In sum, our method provides a valuable new tool for research on adipose tissue that may pave the way for the identification of novel biomarkers of obesity and metabolic disease.
Collapse
Affiliation(s)
- A Fernández-Vega
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | | | - B M Prentice
- Department of Chemistry, University of Florida, Gainesville, FL, USA
| | - D Anderson
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA
| | - F Priego-Capote
- Department of Analytical Chemistry, IMIBIC/UCO/HURS, Cordoba, Spain
| | - M A López-Bascón
- Department of Analytical Chemistry, IMIBIC/UCO/HURS, Cordoba, Spain
| | | | - M S Avendaño
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - R Guzmán-Ruiz
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - M Tena-Sempere
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain
| | - J A Fernández
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940, Leioa, Spain
| | - R M Caprioli
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biochemistry, Vanderbilt University, Nashville, TN, 37232, USA; Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940, Leioa, Spain; Department of Chemistry, Vanderbilt University, Nashville, TN, 37232, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, 37232, USA; Department of Pharmacology, Vanderbilt University, Nashville, TN, 37232, USA; Department of Medicine, Vanderbilt University, Nashville, TN, 37232, USA
| | - M M Malagón
- Dept. Cell Biology, Physiology, and Immunology, IMIBIC/University of Cordoba (UCO)/Reina Sofia University Hospital (HURS), Cordoba, Spain; CIBER Physiopathology of Obesity and Nutrition (CIBERobn), ISCIII, Spain.
| |
Collapse
|
29
|
Van Nuffel S, Quatredeniers M, Pirkl A, Zakel J, Le Caer JP, Elie N, Vanbellingen QP, Dumas SJ, Nakhleh MK, Ghigna MR, Fadel E, Humbert M, Chaurand P, Touboul D, Cohen-Kaminsky S, Brunelle A. Multimodal Imaging Mass Spectrometry to Identify Markers of Pulmonary Arterial Hypertension in Human Lung Tissue Using MALDI-ToF, ToF-SIMS, and Hybrid SIMS. Anal Chem 2020; 92:12079-12087. [PMID: 32786503 DOI: 10.1021/acs.analchem.0c02815] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Pulmonary arterial hypertension (PAH) is a rare and deadly disease affecting roughly 15-60 people per million in Europe with a poorly understood pathology. There are currently no diagnostic tools for early detection nor does a curative treatment exist. The lipid composition of arteries in lung tissue samples from human PAH and control patients were investigated using matrix-assisted laser desorption ionization (MALDI) imaging mass spectrometry (IMS) combined with time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging. Using random forests as an IMS data analysis technique, it was possible to identify the ion at m/z 885.6 as a marker of PAH in human lung tissue. The m/z 885.6 ion intensity was shown to be significantly higher around diseased arteries and was confirmed to be a diacylglycerophosphoinositol PI(C18:0/C20:4) via MS/MS using a novel hybrid SIMS instrument. The discovery of a potential biomarker opens up new research avenues which may finally lead to a better understanding of the PAH pathology and highlights the vital role IMS can play in modern biomedical research.
Collapse
Affiliation(s)
- Sebastiaan Van Nuffel
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Marceau Quatredeniers
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | | | - Julia Zakel
- IONTOF GmbH, Heisenbergstraße 15, 48149 Münster, Germany
| | - Jean-Pierre Le Caer
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Nicolas Elie
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Quentin P Vanbellingen
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Sébastien Joël Dumas
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Morad Kamel Nakhleh
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Maria-Rosa Ghigna
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Elie Fadel
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Marc Humbert
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France.,Assistance Publique - Hôpitaux de Paris (AP-HP), Department of Respiratory and Intensive Care Medicine, Pulmonary Hypertension National Referral Center, Hôpital Bicêtre, Le Kremlin-Bicêtre, France
| | - Pierre Chaurand
- Department of Chemistry, Université de Montréal, Montréal, QC, Canada
| | - David Touboul
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France
| | - Sylvia Cohen-Kaminsky
- Université Paris-Saclay, School of Medicine, Le Kremlin-Bicêtre, France.,INSERM UMR_S 999, Pulmonary Hypertension: Pathophysiology and Novel Therapies, Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Alain Brunelle
- Université Paris-Saclay, CNRS, Institut de Chimie des Substances Naturelles, UPR 2301, 91198, Gif-sur-Yvette, France.,Laboratoire d'Archéologie Moléculaire et Structurale, LAMS UMR8220, CNRS, Sorbonne Université, 4 place Jussieu, 75005 Paris, France
| |
Collapse
|
30
|
Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection. Anal Bioanal Chem 2020; 412:6875-6886. [PMID: 32712813 PMCID: PMC7496020 DOI: 10.1007/s00216-020-02818-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/08/2020] [Accepted: 07/14/2020] [Indexed: 12/23/2022]
Abstract
MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample surface. Subsequently, mass spectrometric images for any recorded ion species can be generated by displaying the signal intensity at the coordinate of origin for each of these pixels. Although easily equalized, these recorded signal intensities, however, are not necessarily a good measure for the underlying amount of analyte and care has to be taken in the interpretation of MALDI-MSI data. Physical and chemical properties that define the analyte molecules’ adjacencies in the tissue largely influence the local extraction and ionization efficiencies, possibly leading to strong variations in signal intensity response. Here, we inspect the validity of signal intensity distributions recorded from murine cerebellum as a measure for the underlying molar distributions. Based on segmentation derived from MALDI-MSI measurements, laser microdissection (LMD) was used to cut out regions of interest with a homogenous signal intensity. The molar concentration of six exemplary selected membrane lipids from different lipid classes in these tissue regions was determined using quantitative nano-HPLC-ESI-MS. Comparison of molar concentrations and signal intensity revealed strong deviations between underlying concentration and the distribution suggested by MSI data. Determined signal intensity response factors strongly depend on tissue type and lipid species. Graphical abstract ![]()
Collapse
|
31
|
Yang E, Fournelle F, Chaurand P. Silver spray deposition for AgLDI imaging MS of cholesterol and other olefins on thin tissue sections. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4428. [PMID: 31410898 DOI: 10.1002/jms.4428] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 07/26/2019] [Accepted: 08/05/2019] [Indexed: 06/10/2023]
Abstract
Olefins such as cholesterol and unsaturated fatty acids play important biological roles. Silver-assisted laser desorption ionization (AgLDI) takes advantage of the strong affinity of silver to conjugate with double bonds to selectively ionize these molecules for imaging mass spectrometry (IMS) experiments. For IMS studies, two main approaches for silver deposition have been described in the literature: fine coating by silver sputtering and spray deposition of silver nanoparticles. While these approaches allow for extremely high resolution IMS experiments to be conducted, they are not readily available to all laboratories. Herein, we present a silver nitrate spray deposition approach as an alternative to silver sputtering and nanoparticle deposition for routine IMS analysis. The silver nitrate spray has the same level of specificity and sensitivity for olefins, particularly cholesterol, and has shown to be capable of IMS experiments down to 10-μm spatial resolution. Minimal sample preparation and the affordability of silver nitrate make this a convenient and accessible technique worth considering.
Collapse
Affiliation(s)
- Ethan Yang
- Department of Chemistry, University of Montreal, Montreal, Quebec, Canada, H3C 3J7
| | - Frédéric Fournelle
- Department of Chemistry, University of Montreal, Montreal, Quebec, Canada, H3C 3J7
| | - Pierre Chaurand
- Department of Chemistry, University of Montreal, Montreal, Quebec, Canada, H3C 3J7
| |
Collapse
|
32
|
Fournelle F, Yang E, Dufresne M, Chaurand P. Minimizing Visceral Fat Delocalization on Tissue Sections with Porous Aluminum Oxide Slides for Imaging Mass Spectrometry. Anal Chem 2020; 92:5158-5167. [DOI: 10.1021/acs.analchem.9b05665] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Frédéric Fournelle
- Department of Chemistry, Université de Montréal, Montreal, Quebec, Canada H2V 0B3
| | - Ethan Yang
- Department of Chemistry, Université de Montréal, Montreal, Quebec, Canada H2V 0B3
| | - Martin Dufresne
- Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37205, United States
| | - Pierre Chaurand
- Department of Chemistry, Université de Montréal, Montreal, Quebec, Canada H2V 0B3
| |
Collapse
|
33
|
Boskamp MS, Soltwisch J. Charge Distribution between Different Classes of Glycerophospolipids in MALDI-MS Imaging. Anal Chem 2020; 92:5222-5230. [DOI: 10.1021/acs.analchem.9b05761] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Marcel S. Boskamp
- Institute of Hygiene, Westfälische Wilhelms-Universität Münster, Münster, Germany
| | - Jens Soltwisch
- Institute of Hygiene, Westfälische Wilhelms-Universität Münster, Münster, Germany
- Interdisciplinary Center for Clinical Research (IZKF), Westfälische Wilhelms-Universität Münster, Münster, Germany
| |
Collapse
|
34
|
Schäfermann J, Kliewer G, Lösch J, Bednarz H, Giampà M, Niehaus K. Immersion by rotation-based application of the matrix for fast and reproducible sample preparations and robust results in mass spectrometry imaging. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4488. [PMID: 31826308 DOI: 10.1002/jms.4488] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 11/22/2019] [Accepted: 12/08/2019] [Indexed: 06/10/2023]
Abstract
Automated matrix deposition for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is crucial for producing reproducible analyte ion signals. Here we report an innovative method employing an automated immersion apparatus, which enables a robust matrix deposition within 5 minutes and with scalable throughput by using MAPS matrix and non-polar solvents. MSI results received from mouse heart and rat brain tissues were qualitatively similar to those from nozzle sprayed samples with respect to peak number and quality of the ion images. Overall, the immersion-method enables a fast and careful matrix deposition and has the future potential for implementation in clinical tissue diagnostics.
Collapse
Affiliation(s)
- Johanna Schäfermann
- MSI Diagnostics GmbH, Bielefeld, Germany
- Proteome and Metabolome Research, Faculty of Biology, Bielefeld University, Bielefeld, Germany
| | - Georg Kliewer
- MSI Diagnostics GmbH, Bielefeld, Germany
- Proteome and Metabolome Research, Faculty of Biology, Bielefeld University, Bielefeld, Germany
| | | | - Hanna Bednarz
- Center for Biotechnology, Bielefeld University, Bielefeld, Germany
- Proteome and Metabolome Research, Faculty of Biology, Bielefeld University, Bielefeld, Germany
| | - Marco Giampà
- Department of Clinical and Molecular Medicine, Norwegian University of Science and Technology, Trondheim, Norway
| | - Karsten Niehaus
- Center for Biotechnology, Bielefeld University, Bielefeld, Germany
- Proteome and Metabolome Research, Faculty of Biology, Bielefeld University, Bielefeld, Germany
| |
Collapse
|
35
|
Bowman AP, Bogie JFJ, Hendriks JJA, Haidar M, Belov M, Heeren RMA, Ellis SR. Evaluation of lipid coverage and high spatial resolution MALDI-imaging capabilities of oversampling combined with laser post-ionisation. Anal Bioanal Chem 2019; 412:2277-2289. [PMID: 31879798 PMCID: PMC7118047 DOI: 10.1007/s00216-019-02290-3] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/04/2019] [Accepted: 11/18/2019] [Indexed: 01/28/2023]
Abstract
Matrix-assisted laser desorption/ionisation-mass spectrometry imaging (MALDI-MSI) is a powerful technique for visualising the spatial locations of lipids in biological tissues. However, a major challenge in interpreting the biological significance of local lipid compositions and distributions detected using MALDI-MSI is the difficulty in associating spectra with cellular lipid metabolism within the tissue. By-and-large this is due to the typically limited spatial resolution of MALDI-MSI (30–100 μm) meaning individual spectra represent the average spectrum acquired from multiple adjacent cells, each potentially possessing a unique lipid composition and biological function. The use of oversampling is one promising approach to decrease the sampling area and improve the spatial resolution in MALDI-MSI, but it can suffer from a dramatically decreased sensitivity. In this work we overcome these challenges through the coupling of oversampling MALDI-MSI with laser post-ionisation (MALDI-2). We demonstrate the ability to acquire rich lipid spectra from pixels as small as 6 μm, equivalent to or smaller than the size of typical mammalian cells. Coupled with an approach for automated lipid identification, it is shown that MALDI-2 combined with oversampling at 6 μm pixel size can detect up to three times more lipids and many more lipid classes than even conventional MALDI at 20 μm resolution in the positive-ion mode. Applying this to mouse kidney and human brain tissue containing active multiple sclerosis lesions, where 74 and 147 unique lipids are identified, respectively, the localisation of lipid signals to individual tubuli within the kidney and lipid droplets with lesion-specific macrophages is demonstrated. Graphical abstract ![]()
Collapse
Affiliation(s)
- Andrew P Bowman
- Maastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6629, ER, Maastricht, The Netherlands
| | - Jeroen F J Bogie
- Department of Immunology and Biochemistry, Biomedical Research Institute, Hasselt University, 3590, Diepenbeek, Belgium
| | - Jerome J A Hendriks
- Department of Immunology and Biochemistry, Biomedical Research Institute, Hasselt University, 3590, Diepenbeek, Belgium
| | - Mansour Haidar
- Department of Immunology and Biochemistry, Biomedical Research Institute, Hasselt University, 3590, Diepenbeek, Belgium
| | | | - Ron M A Heeren
- Maastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6629, ER, Maastricht, The Netherlands
| | - Shane R Ellis
- Maastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6629, ER, Maastricht, The Netherlands.
| |
Collapse
|
36
|
Zhang L, Dai C, Zhang J. 3D ToF‐SIMS view of interfacial diffusion between Cr
2
AlC coating and zircaloy substrate. SURF INTERFACE ANAL 2019. [DOI: 10.1002/sia.6715] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Lei Zhang
- Shenyang National Laboratory for Materials Science, Institute of Metal ResearchChinese Academy of Sciences Shenyang China
| | - Chunli Dai
- Shenyang National Laboratory for Materials Science, Institute of Metal ResearchChinese Academy of Sciences Shenyang China
| | - Jie Zhang
- Shenyang National Laboratory for Materials Science, Institute of Metal ResearchChinese Academy of Sciences Shenyang China
| |
Collapse
|
37
|
Taylor MJ, Graham DJ, Gamble LJ. Time-of-flight secondary ion mass spectrometry three-dimensional imaging of surface modifications in poly(caprolactone) scaffold pores. J Biomed Mater Res A 2019; 107:2195-2204. [PMID: 31116499 PMCID: PMC6690353 DOI: 10.1002/jbm.a.36729] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/14/2019] [Accepted: 05/20/2019] [Indexed: 01/24/2023]
Abstract
Scaffolds composed of synthetic polymers such as poly(caprolactone) (PCL) are widely used for the support and repair of tissues in biomedicine. Pores are common features in scaffolds as they facilitate cell penetration. Various surface modifications can be performed to promote key biological responses to these scaffolds. However, verifying the chemistry of these materials post surface modification is problematic due to the combination of three-dimensional (3D) topography and surface sensitivity. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is commonly used to correlate surface chemistry with cell response. In this study, 3D imaging mass spectrometry analysis of surface modified synthetic polymer scaffolds is demonstrated using PCL porous scaffold, a pore filling polymer sample preparation, and 3D imaging ToF-SIMS. We apply a simple sample preparation procedure, filling the scaffold pores with a poly(vinyl alcohol)/glycerol mixture to remove topographic influence on image quality. This filling method allows the scaffold (PCL) and filler secondary ions to be reconstructed into a 3D chemical image of the pore. Furthermore, we show that surface modifications in the pores of synthetic polymer scaffolds can be mapped in 3D. Imaging of "dry" and "wet" surface modifications is demonstrated as well as a comparison of surface modifications with relatively strong ToF-SIMS peaks (fluorocarbon films [FC]) and to more biologically relevant surface modification of a protein (bovine serum albumin [BSA]). We demonstrate that surface modifications can be imaged in 3D showing that characteristic secondary ions associated with FC and BSA are associated with C3 F8 plasma treatment and BSA, respectively within the pore.
Collapse
Affiliation(s)
- Michael J Taylor
- NESAC/BIO, Department of Bioengineering, University of Washington, Seattle, Washington
| | - Daniel J Graham
- NESAC/BIO, Department of Bioengineering, University of Washington, Seattle, Washington
| | - Lara J Gamble
- NESAC/BIO, Department of Bioengineering, University of Washington, Seattle, Washington
| |
Collapse
|
38
|
Dufresne M, Patterson NH, Norris JL, Caprioli RM. Combining Salt Doping and Matrix Sublimation for High Spatial Resolution MALDI Imaging Mass Spectrometry of Neutral Lipids. Anal Chem 2019; 91:12928-12934. [DOI: 10.1021/acs.analchem.9b02974] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Martin Dufresne
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, Tennessee 37235, United States
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, Tennessee 37205, United States
| | - Nathan Heath Patterson
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, Tennessee 37235, United States
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, Tennessee 37205, United States
| | - Jeremy Lynn Norris
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, Tennessee 37235, United States
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, Tennessee 37205, United States
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, Tennessee 37235, United States
| | - Richard Micheal Caprioli
- Mass Spectrometry Research Center, Vanderbilt University, 465 21st Ave S #9160, Nashville, Tennessee 37235, United States
- Department of Biochemistry, Vanderbilt University, 607 Light Hall, Nashville, Tennessee 37205, United States
- Department of Chemistry, Vanderbilt University, 7330 Stevenson Center, Station B 351822, Nashville, Tennessee 37235, United States
- Department of Pharmacology, Vanderbilt University, 442 Robinson Research Building, 2220 Pierce Avenue, Nashville, Tennessee 37232, United States
- Department of Medicine, Vanderbilt University, 465 21st Ave S #9160, Nashville, Tennessee 37235, United States
| |
Collapse
|
39
|
Quantitative Mass Spectrometry Imaging Reveals Mutation Status-independent Lack of Imatinib in Liver Metastases of Gastrointestinal Stromal Tumors. Sci Rep 2019; 9:10698. [PMID: 31337874 PMCID: PMC6650609 DOI: 10.1038/s41598-019-47089-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 07/09/2019] [Indexed: 01/08/2023] Open
Abstract
Mass spectrometry imaging (MSI) is an enabling technology for label-free drug disposition studies at high spatial resolution in life science- and pharmaceutical research. We present the first extensive clinical matrix-assisted laser desorption/ionization (MALDI) quantitative mass spectrometry imaging (qMSI) study of drug uptake and distribution in clinical specimen, analyzing 56 specimens of tumor and corresponding non-tumor tissues from 27 imatinib-treated patients with the biopsy-proven rare disease gastrointestinal stromal tumors (GIST). For validation, we compared MALDI-TOF-qMSI with conventional UPLC-ESI-QTOF-MS-based quantification from tissue extracts and with ultra-high resolution MALDI-FTICR-qMSI. We introduced a novel generalized nonlinear calibration model of drug quantities based on computational evaluation of drug-containing areas that enabled better data fitting and assessment of the inherent method nonlinearities. Imatinib tissue spatial maps revealed striking inefficiency in drug penetration into GIST liver metastases even though the corresponding healthy liver tissues in the vicinity showed abundant imatinib levels beyond the limit of quantification (LOQ), thus providing evidence for secondary drug resistance independent of mutation status. Taken together, these findings underscore the important application of MALDI-qMSI in studying the spatial distribution of molecularly targeted therapeutics in oncology, namely to serve as orthogonal post-surgical approach to evaluate the contribution of anticancer drug disposition to resistance against treatment.
Collapse
|
40
|
Nozaki K, Nakabayashi Y, Murakami T, Miyazato A, Osaka I. Novel approach to enhance sensitivity in surface-assisted laser desorption/ionization mass spectrometry imaging using deposited organic-inorganic hybrid matrices. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:612-619. [PMID: 31070274 DOI: 10.1002/jms.4370] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 04/16/2019] [Accepted: 05/02/2019] [Indexed: 06/09/2023]
Abstract
Sample pretreatment is key to obtaining good data in matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Although sublimation is one of the best methods for obtaining homogenously fine organic matrix crystals, its sensitivity can be low due to the lack of a solvent extraction effect. We investigated the effect of incorporating a thin film of metal formed by zirconium (Zr) sputtering into the sublimation process for MALDI matrix deposition for improving the detection sensitivity in mouse liver tissue sections treated with olanzapine. The matrix-enhanced surface-assisted laser desorption/ionization (ME-SALDI) method, where a matrix was formed by sputtering Zr to form a thin nanoparticle layer before depositing MALDI organic matrix comprising α-cyano-4-hydroxycinnamic acid (CHCA) by sublimation, resulted in a significant improvement in sensitivity, with the ion intensity of olanzapine being about 1800 times that observed using the MALDI method, comprising CHCA sublimation alone. When Zr sputtering was performed after CHCA deposition, however, no such enhancement in sensitivity was observed. The enhanced sensitivity due to Zr sputtering was also observed when the CHCA solution was applied by spraying, being about twice as high as that observed by CHCA spraying alone. In addition, the detection sensitivity of these various pretreatment methods was similar for endogenous glutathione. Given that sample preparation using the ME-SALDI-MSI method, which combines Zr sputtering with the sublimation method for depositing an organic matrix, does not involve a solvent, delocalization problems such as migration of analytes observed after matrix spraying and washing with aqueous solutions as sample pretreatment are not expected. Therefore, ME-Zr-SALDI-MSI is a novel sample pretreatment method that can improve the sensitivity of analytes while maintaining high spatial resolution in MALDI-MSI.
Collapse
Affiliation(s)
- Kazuyoshi Nozaki
- Bioimaging, Analysis & Pharmacokinetics Research Labs. Drug Discovery research, Astellas Pharma Inc, 21 Miyukigaoka, Tsukuba-shi, Ibaraki, 305-8585, Japan
| | - Yuji Nakabayashi
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Tatsuya Murakami
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Akio Miyazato
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Issey Osaka
- Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-City, Toyama, 939-0398, Japan
| |
Collapse
|
41
|
Gilmore IS, Heiles S, Pieterse CL. Metabolic Imaging at the Single-Cell Scale: Recent Advances in Mass Spectrometry Imaging. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2019; 12:201-224. [PMID: 30848927 DOI: 10.1146/annurev-anchem-061318-115516] [Citation(s) in RCA: 116] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
There is an increasing appreciation that every cell, even of the same type, is different. This complexity, when additionally combined with the variety of different cell types in tissue, is driving the need for spatially resolved omics at the single-cell scale. Rapid advances are being made in genomics and transcriptomics, but progress in metabolomics lags. This is partly because amplification and tagging strategies are not suited to dynamically created metabolite molecules. Mass spectrometry imaging has excellent potential for metabolic imaging. This review summarizes the recent advances in two of these techniques: matrix-assisted laser desorption ionization (MALDI) and secondary ion mass spectrometry (SIMS) and their convergence in subcellular spatial resolution and molecular information. The barriers that have held back progress such as lack of sensitivity and the breakthroughs that have been made including laser-postionization are highlighted as well as the future challenges and opportunities for metabolic imaging at the single-cell scale.
Collapse
Affiliation(s)
- Ian S Gilmore
- National Physical Laboratory, Teddington, Middlesex, TW11 0LW, United Kingdom; k
| | - Sven Heiles
- Institute of Inorganic and Analytical Chemistry , Justus Liebig University Giessen, D-35392 Giessen, Germany
| | - Cornelius L Pieterse
- National Physical Laboratory, Teddington, Middlesex, TW11 0LW, United Kingdom; k
| |
Collapse
|
42
|
Development and evaluation of matrix application techniques for high throughput mass spectrometry imaging of tissues in the clinic. CLINICAL MASS SPECTROMETRY 2019; 12:7-15. [DOI: 10.1016/j.clinms.2019.01.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 01/27/2019] [Accepted: 01/28/2019] [Indexed: 01/05/2023]
|
43
|
Schulz S, Becker M, Groseclose MR, Schadt S, Hopf C. Advanced MALDI mass spectrometry imaging in pharmaceutical research and drug development. Curr Opin Biotechnol 2019; 55:51-59. [DOI: 10.1016/j.copbio.2018.08.003] [Citation(s) in RCA: 115] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 07/21/2018] [Accepted: 08/03/2018] [Indexed: 12/20/2022]
|
44
|
Fernández R, Garate J, Martín-Saiz L, Galetich I, Fernández JA. Matrix Sublimation Device for MALDI Mass Spectrometry Imaging. Anal Chem 2018; 91:803-807. [DOI: 10.1021/acs.analchem.8b04765] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Roberto Fernández
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio
Sarriena S/N, Leioa 48940, Spain
| | - Jone Garate
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio
Sarriena S/N, Leioa 48940, Spain
| | - Lucia Martín-Saiz
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio
Sarriena S/N, Leioa 48940, Spain
| | - Igor Galetich
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio
Sarriena S/N, Leioa 48940, Spain
| | - José A. Fernández
- Department of Physical Chemistry, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), Barrio
Sarriena S/N, Leioa 48940, Spain
| |
Collapse
|
45
|
Schaepe K, Bhandari DR, Werner J, Henss A, Pirkl A, Kleine-Boymann M, Rohnke M, Wenisch S, Neumann E, Janek J, Spengler B. Imaging of Lipids in Native Human Bone Sections Using TOF-Secondary Ion Mass Spectrometry, Atmospheric Pressure Scanning Microprobe Matrix-Assisted Laser Desorption/Ionization Orbitrap Mass Spectrometry, and Orbitrap-Secondary Ion Mass Spectrometry. Anal Chem 2018; 90:8856-8864. [PMID: 29944823 DOI: 10.1021/acs.analchem.8b00892] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
A method is described for high-resolution label-free molecular imaging of human bone tissue. To preserve the lipid content and the heterogeneous structure of osseous tissue, 4 μm thick human bone sections were prepared via cryoembedding and tape-assisted cryosectioning, circumventing the application of organic solvents and a decalcification step. A protocol for comparative mass spectrometry imaging (MSI) on the same section was established for initial analysis with time-of-flight secondary ion mass spectrometry (TOF-SIMS) at a lateral resolution of 10 μm to <500 nm, followed by atmospheric pressure scanning microprobe matrix-assisted laser desorption/ionization (AP-SMALDI) Orbitrap MSI at a lateral resolution of 10 μm. This procedure ultimately enabled MSI of lipids, providing the lateral localization of major lipid classes such as glycero-, glycerophospho-, and sphingolipids. Additionally, the applicability of the recently emerged Orbitrap-TOF-SIMS hybrid system was exemplarily examined and compared to the before-mentioned MSI methods.
Collapse
Affiliation(s)
| | | | - Janina Werner
- Department of Veterinary Clinical Sciences , Small Animal Clinic, Institute of Veterinary Anatomy, Histology and Embryology, Justus Liebig University Giessen , Frankfurter Strasse 98 , 35392 Giessen , Germany
| | | | - Alexander Pirkl
- IONTOF GmbH , Heisenbergstrasse 15 , 48149 Münster , Germany
| | | | | | - Sabine Wenisch
- Department of Veterinary Clinical Sciences , Small Animal Clinic, Institute of Veterinary Anatomy, Histology and Embryology, Justus Liebig University Giessen , Frankfurter Strasse 98 , 35392 Giessen , Germany
| | - Elena Neumann
- Department of Internal Medicine and Rheumatology , Justus Liebig University Giessen, Kerckhoff-Clinic , Benekestrasse 2-8 , 61231 Bad Nauheim , Germany
| | | | | |
Collapse
|