1
|
Wang P, Li J, Xie MY, Wu CC, Wong CS, Zeng EY. Utility of a modified o-DGT passive sampler for measurement of bisphenol analogues in freshwater and coastal waters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 931:172978. [PMID: 38705295 DOI: 10.1016/j.scitotenv.2024.172978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Revised: 04/23/2024] [Accepted: 05/02/2024] [Indexed: 05/07/2024]
Abstract
Bisphenol analogues (BPs) are commonly found in riverine and coastal waters. However, the lack of a reliable and robust passive sampling method has hindered our ability to monitor these compounds in aquatic systems. The study developed a novel organic-diffusive gradients in thin film (o-DGT) sampler based on stainless steel mesh membrane, polyacrylamide diffusive gel, and hydrophilic-lipophilic balance (HLB) binding gel. This innovative design tackled issues of filter membrane sorption in traditional o-DGT devices and potential gel damage in membrane-less o-DGT devices, showing promising application prospects. The mass accumulation of 15 target BPs was linear over 10 days in both freshwater (r2 ≥ 0.92) and seawater (r2 ≥ 0.94), with no saturation observed. The diffusion coefficients (D) through polyacrylamide diffusive gels ranged from 4.04 × 10-6 to 5.77 × 10-6 cm2 s-1 in freshwater and from 1.74 × 10-6 to 4.69 × 10-6 cm2 s-1 in seawater for the target BPs (except for bisphenol PH) at 22 °C. The D values of the target BPs in seawater were lower than those in freshwater due to the high salinity in seawater (35 ‰). The o-DGT samplers demonstrated good integrity in field applications. The total concentrations of the eight detected BPs ranged from 9.2 to 323 ng L-1, which was consistent with the measurements obtained by grab sampling. Among all BPs, bisphenol S, bisphenol F, and bisphenol A were consistently detected at all sites using both sampling methods. The concentrations of some novel BPs in coastal water measured by grab sampling were comparable to those measured in rivers, suggesting the need to strengthen pollution control of BPs in coastal areas. These results indicate that the o-DGT passive sampling method developed in the present study can be effectively used for monitoring BPs in freshwater and coastal environments.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 511443, China
| | - Jie Li
- Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 511443, China
| | - Meng Yi Xie
- Key Laboratory of Pollution Control and Ecosystem Restoration in Industry Clusters (Ministry of Education), School of Environment and Energy, South China University of Technology, Guangzhou 510006, China
| | - Chen Chou Wu
- Guangdong Key Laboratory of Environmental Pollution and Health, Jinan University, Guangzhou 511443, China; Key Laboratory of Pollution Control and Ecosystem Restoration in Industry Clusters (Ministry of Education), School of Environment and Energy, South China University of Technology, Guangzhou 510006, China
| | - Charles S Wong
- Southern California Coastal Water Research Project Authority, Costa Mesa, CA 92626, USA
| | - Eddy Y Zeng
- Key Laboratory of Pollution Control and Ecosystem Restoration in Industry Clusters (Ministry of Education), School of Environment and Energy, South China University of Technology, Guangzhou 510006, China.
| |
Collapse
|
2
|
Cao H, Bu Q, Li Q, Yang L, Tang J, Yu G. Evaluation of the DGT passive samplers for integrating fluctuating concentrations of pharmaceuticals in surface water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 926:172067. [PMID: 38565352 DOI: 10.1016/j.scitotenv.2024.172067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 02/24/2024] [Accepted: 03/26/2024] [Indexed: 04/04/2024]
Abstract
Diffusive gradients in thin films (DGTs) have been well-documented for the measurement of a broad range of organic pollutants in surface water. However, the performance has been challenged by the inherent periodic concentration fluctuations for most organic pollutants. Therefore, there is an urgent need to assess the true time-weighted average (TWA) concentration based on fluctuating concentration profiles. The study aimed to evaluate the responsiveness of DGT and accuracy of TWA concentrations, considering various concentration fluctuating scenarios of 20 pharmaceuticals in surface water. The reliability and accuracy of the TWA concentrations measured by the DGT were assessed by comparison with the sum of cumulative mass of DGT exposed at different stages over the deployment period. The results showed that peak concentration duration (1-5 days), peak concentration fluctuation intensity (6-20 times), and occurrence time of peak concentration fluctuation (early, middle, and late stages) have minimal effect on DGT's response to most target pharmaceutical concentration fluctuations (0.8 < CDGT/CTWA < 1.2). While the downward-bent accumulations of a few pharmaceuticals on DGT occur as the sampling time increases, which could be accounted for by capacity effects during a long-time sampling period. Additionally, the DGT device had good sampling performance in recording short fluctuating concentrations from a pulse event returning to background concentrations with variable intensity and duration. This study revealed a satisfactory capacity for the evaluation of the TWA concentration of pharmaceuticals integrated over the period of different pulse deployment for DGT, suggesting that this passive sampler is ideally suited as a monitoring tool for field application. This study represents the first trial for evaluating DGT sampling performance for pharmaceuticals with multiple concentration fluctuating scenarios over time, which would be valuable for assessing the pollution status in future monitoring campaign.
Collapse
Affiliation(s)
- Hongmei Cao
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing 100083, PR China; School of Environmental Science and Engineering, College of Engineering, Southern University of Science and Technology, Shenzhen 518055, PR China
| | - Qingwei Bu
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing 100083, PR China.
| | - Qingshan Li
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing 100083, PR China
| | - Lei Yang
- State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Science, Chinese Academy of Sciences, Beijing 100085, PR China
| | - Jianfeng Tang
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, PR China
| | - Gang Yu
- Advanced Interdisciplinary Institute of Environment and Ecology, Beijing Normal University (Zhuhai Campus), Zhuhai 519087, PR China
| |
Collapse
|
3
|
Dong F, Ge F, Zhao X, Sun D, Ren S, Wang Y, Tan F. Measurement of perfluoroalkyl substances in drinking water sources by DGT sampler with a novel fluorinated graphite binding gel. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169658. [PMID: 38159764 DOI: 10.1016/j.scitotenv.2023.169658] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 12/20/2023] [Accepted: 12/22/2023] [Indexed: 01/03/2024]
Abstract
Extensive use of per- and polyfluoroalkyl substances (PFASs) has resulted in their widespread presence in natural waters. Concern for public health requires reliable measurement methods for determining their distribution and risks. Here, a sampling method based on diffusive gradients in thin films (DGT) was developed for measuring PFASs in drinking water sources. Fluorinated graphite (FG) particles were used to prepare the DGT binding gel for selective enrichment of trace PFASs in an aqueous environment. The FG-DGT method did not show sensitivity to relevant environmental parameters including pH (5.0-9.0), ionic strength (0.001-0.5 M), or DOM concentration (0-30 mg/L). The FG-DGT had enough capacity for deployment of up to four months. Six traditional and emerging PFASs including PFOS, PFOA, PFHpA, PFHxS, PFNA, and 6:2 FTSA at the ng/L level were detected in two major reservoirs serving as public drinking water sources by FG-DGT method coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). PFOA appeared at the highest observed concentrations in the drinking water sources. The research demonstrates that FG-DGT is an effective and efficient tool for monitoring PFASs in drinking water.
Collapse
Affiliation(s)
- Fan Dong
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Fan Ge
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Xinting Zhao
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Daming Sun
- Dalian Hydrological Bureau of Liaoning Province, Dalian 116023, China
| | - Suyu Ren
- School of Environmental and Material Engineering, Yantai University, Yan Tai 264005, China
| | - Yan Wang
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Feng Tan
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
| |
Collapse
|
4
|
Fialová P, Šverclová K, Grabicová K, Grabic R, Švecová H, Nováková P, Vrana B. Performance comparison of three passive samplers for monitoring of polar organic contaminants in treated municipal wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168153. [PMID: 37914129 DOI: 10.1016/j.scitotenv.2023.168153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 10/24/2023] [Accepted: 10/25/2023] [Indexed: 11/03/2023]
Abstract
Over the past decades, several types of passive samplers have been developed and used to monitor polar organic compounds in aquatic environments. These samplers use different sorbents and barriers to control the uptake into the sampler, but their performance comparison is usually not well investigated. This study aimed to directly compare the performance of three samplers, i.e., the Polar Organic Chemical Integrative Sampler (POCIS), the Hydrogel-based Passive Sampler (HPS, an upscaled version of o-DGT), and the Speedisk, on a diverse suite of pharmaceuticals, per- and polyfluoroalkylated substances (PFAS), and pesticides and their metabolites. The samplers were deployed side-by-side in the treated effluent of a municipal wastewater treatment plant for different exposure times. All samplers accumulated a comparable number of compounds, and integrative uptake was observed for most compounds detected up to 28 days for POCIS, up to 14 days for HPS, and up to 42 days for Speedisk. In the integrative uptake phase, consistent surface-specific uptake was observed with a significant correlation between samplers (r ≥ 0.76) despite differences in sampler construction, diffusion barrier, and sorbent material used. The low sampling rates compared to the literature and the low estimated overall mass transfer coefficient suggests that the water boundary layer was the main barrier controlling the uptake for all samplers. Although all devices provided comparable performance, Speedisk overcomes POCIS and HPS in several criteria, including time-integrative sampling over a long period and physical durability.
Collapse
Affiliation(s)
- Pavla Fialová
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic; University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Kateřina Šverclová
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic
| | - Kateřina Grabicová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Roman Grabic
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Helena Švecová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Petra Nováková
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, 38925 Vodňany, Czech Republic
| | - Branislav Vrana
- RECETOX, Faculty of Science, Masaryk University, Kotlářská 2, Brno 61137, Czech Republic.
| |
Collapse
|
5
|
Yu X, Wang Y, Watson P, Yang X, Liu H. Application of passive sampling device for exploring the occurrence, distribution, and risk of pharmaceuticals and pesticides in surface water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168393. [PMID: 37963530 DOI: 10.1016/j.scitotenv.2023.168393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Revised: 10/31/2023] [Accepted: 11/05/2023] [Indexed: 11/16/2023]
Abstract
Pharmaceuticals and pesticides are compounds of high concern in surface waters around the world. However, few studies have used passive sampling methods to screen and detect these compounds in natural waters. In this study, a self-developed passive sampler was employed to measure pharmaceuticals and pesticides in the rivers of Nanjing, China. A total of 41 pharmaceuticals and 11 pesticides were detected, among which antibiotic and insecticide were the predominant classes, respectively. Valproic acid, caffeine and triclosan from the pharmaceuticals, and isoprocarb and imidacloprid from the pesticides were found frequently with high concentrations. At most sampling sites, the concentration ratios of caffeine versus carbamazepine exceeded 10, and even above 50, indicating relatively poor efficiency of wastewater treatment, or possibly the direct discharge of raw sewage, or other unknown source of pollution. It was found that the concentrations and ecological risks in the northern area of Yangtze River were higher than those in the southern area of Yangtze River, implying that economic development and population density were not the main contributors to the discovered pollution. The total concentration of pharmaceuticals and pesticides in Qinhuai River increased gradually with the direction of water flow, demonstrating the success of water diversion project in flushing and scouring pollutants.
Collapse
Affiliation(s)
- Xinzhi Yu
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Yaqi Wang
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Peter Watson
- Los Alamos National Laboratory, Los Alamos 87545, NM, United States
| | - Xianhai Yang
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Huihui Liu
- Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
| |
Collapse
|
6
|
Liang Y, Li H, Li S, Chen S. Organic diffusive gradients in thin films (o-DGT) for determining environmental behaviors of antibiotics: A review. JOURNAL OF HAZARDOUS MATERIALS 2023; 459:132279. [PMID: 37597396 DOI: 10.1016/j.jhazmat.2023.132279] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 07/30/2023] [Accepted: 08/11/2023] [Indexed: 08/21/2023]
Abstract
Antibiotics are recognized as effective medicine that has been extensively used in human and veterinary. Since the rate of releasing into the environment is stronger than the rate of elimination, antibiotics are regarded as persistent or "pseudo-persistent" organic compounds that result in the development of microbial antibiotic resistance. Therefore, assessment for their ecological risks to the environment are essential. Diffusive gradients in thin films for organic compounds (o-DGT) have been adapted to investigate the environmental behaviors of antibiotics. Currently, more than 20 compounds have been tested by o-DGT in waters and soil environments. In this review, we explained the theoretical reason that o-DGT is feasible to determine the labile fraction of antibiotics in different environmental media. The most used agarose diffusive gel, and various binding agents such as resin, porous carbon and nano-scale materials have been compared to optimize the sampling of antibiotics by o-DGT. Results of deploying o-DGT devices in waters and soils from previous studies were discussed to understand the bioavailability and dynamic transport of antibiotics. Also, we provided the feasibility analysis of using o-DGT in sediments for antibiotics measurements, which is required to be carried out in future studies. To have a deep view on the development of o-DGT, its technical limitations and viable improvements were summarized in this study for further applications on antibiotics research.
Collapse
Affiliation(s)
- Yixuan Liang
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Hanbing Li
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Sumei Li
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China
| | - Sha Chen
- Department of Environmental Science, Key Laboratory of Beijing on Regional Air Pollution Control, Beijing University of Technology, Beijing 100124, China.
| |
Collapse
|
7
|
Ren S, Jin X, Bekele TG, Lv M, Ding J, Tan F, Chen L. Development and application of diffusive gradients in thin films for in situ sampling of the organic UV filter 4-methylbenzylidene camphor (4-MBC) in waters. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023; 30:92651-92661. [PMID: 37493909 DOI: 10.1007/s11356-023-28844-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Accepted: 07/14/2023] [Indexed: 07/27/2023]
Abstract
4-Methylbenzylidene camphor (4-MBC), a typical organic UV filter (OUVF) in personal care products, is considered to be a potential endocrine disruptor due to its estrogenic activity and bioaccumulation. Although 4-MBC residues have been extensively identified in aquatic waters, little is known about their occurrence, levels, and potential risk in coastal waters. This study developed a reliable sampling approach, based on diffusive gradients in thin films (DGT) with XAD-2 as the binding agent, for monitoring 4-MBC in coastal waters. The diffusion coefficients of 4-MBC in freshwater and artificial seawater were 3.65 × 10-6 cm2/s and 3.83 × 10-6 cm2/s, respectively. XAD-2 binding gel showed rapid adsorption to 4-MBC. The accumulated masses of 4-MBC in XAD-2 DGT increased linearly with deployed time for 7 days in freshwater and seawater, which agreed well with theoretical predictions. The sampling performance was independent of ionic strength (0.0001-0.5 M), pH (4.0-8.5), and dissolved organic matter (0-20 mg/L). Field deployment in the river estuary and bathing beach showed that DGT-measured 4-MBC concentrations were consistent in comparison with grab sampling. Environmental risk assessment showed that 4-MBC may pose a medium risk to aquatic organisms based on computed risk quotient (RQ) values. Sewage discharge is the main source of 4-MBC risk, while the residue in recreation beaches contributes more significantly in summer. The established DGT sampling is suitable for seasonal monitoring, source identification, and risk assessment of 4-MBC in coastal waters.
Collapse
Affiliation(s)
- Suyu Ren
- School of Environmental and Material Engineering, Yantai University, Yantai, 264005, China
| | - Xiaojie Jin
- Shandong Marine Resource and Environment Research Institute, Yantai, 264006, China
| | - Tadiyose Girma Bekele
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024, China
| | - Min Lv
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China
| | - Jing Ding
- School of Environmental and Material Engineering, Yantai University, Yantai, 264005, China
| | - Feng Tan
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024, China.
| | - Lingxin Chen
- CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai, 264003, China
| |
Collapse
|
8
|
Martins de Barros R, Rougerie J, Guibal R, Lissalde S, Buzier R, Simon S, Guibaud G. Interest of a new large diffusive gradients in thin films (L-DGT) for organic compounds monitoring: On-field comparison with conventional passive samplers. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 323:121257. [PMID: 36828359 DOI: 10.1016/j.envpol.2023.121257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/25/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
In this work, the performances of a Large Diffusive Gradients in Thin films (L-DGT, i.e., a DGT based on a Chemcatcher® holder with a 5-fold larger sampling area) were compared on-field with the conventional DGT and the Polar Organic Chemical Integrative Sampler (POCIS) for the monitoring of a wide range of organic contaminants (i.e., 65 pesticides and metabolites, 53 pharmaceuticals and 12 hormones). These three passive samplers were simultaneously deployed in four rivers during 14 days. Their performances were then evaluated according to their detection and quantification capacities and their physical robustness. The results obtained confirm the advantages of the L-DGT over the conventional DGT regarding its sensitivity but also its robustness during field deployment. The POCIS provides the higher sensitivity, allowing the detection of more organic compounds compared to the DGT and, to a lesser extent, the L-DGT. However, both L-DGT and DGT reduces the uncertainty on the determination of the time-weighted average concentrations (CW), mainly due to the narrow range of variation of their calibration parameters. Indeed, for a given compound, CW can vary up to only a 3-fold factor with DGT and L-DGT compared to a 2 to 10-fold factor (up to 50) with POCIS. Thus, the L-DGT appears to be more suitable than DGT in low-contaminated contexts, which require higher sensitivity, or than POCIS when a CW determination is needed. For a qualitative evaluation however, the POCIS remains the most suitable passive sampler.
Collapse
Affiliation(s)
| | - Juliette Rougerie
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| | - Robin Guibal
- University of Limoges, E2Lim, 16 rue Atlantis, 87068 Limoges Cedex, France
| | - Sophie Lissalde
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France.
| | - Rémy Buzier
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| | - Stéphane Simon
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| | - Gilles Guibaud
- University of Limoges, E2Lim, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| |
Collapse
|
9
|
Zi J, Xiao S, Liu S, Chen CE. Passive Sampling: A Greener Technique for the 'Dual Carbon' Goal While Implementing the Action Plan for Controlling Emerging Pollutants. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2022; 110:6. [PMID: 36508015 DOI: 10.1007/s00128-022-03656-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Accepted: 10/31/2022] [Indexed: 06/17/2023]
Abstract
In response to global climate change, China recently committed to achieving peak carbon emissions by 2030 and carbon neutrality by 2060. Carbon emission reduction should be considered in every sector of society including environmental monitoring. As an energy-saving technique in environmental monitoring, passive sampling has many advantages, such as in-situ sampling and a reduction in time/labour requirements. This perspective illustrates the "greenness" of passive sampling techniques, by comparison with traditional sampling methods, and its potential contribution to the 'dual carbon' goal. At the same time passive sampling can provide key support for the action plan for controlling emerging pollutants in China.
Collapse
Affiliation(s)
- Jinxin Zi
- Environmental Research Institute, School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, 510006, Guangzhou, China
| | - Sheng Xiao
- Environmental Research Institute, School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, 510006, Guangzhou, China
| | - Sisi Liu
- Environmental Research Institute, School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, 510006, Guangzhou, China
| | - Chang-Er Chen
- Environmental Research Institute, School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, 510006, Guangzhou, China.
| |
Collapse
|
10
|
Kamali N, Abbas F, Lehane M, Griew M, Furey A. A Review of In Situ Methods-Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) for the Collection and Concentration of Marine Biotoxins and Pharmaceuticals in Environmental Waters. Molecules 2022; 27:7898. [PMID: 36431996 PMCID: PMC9698218 DOI: 10.3390/molecules27227898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 09/14/2022] [Accepted: 09/20/2022] [Indexed: 11/17/2022] Open
Abstract
Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) are in situ methods that have been applied to pre-concentrate a range of marine toxins, pesticides and pharmaceutical compounds that occur at low levels in marine and environmental waters. Recent research has identified the widespread distribution of biotoxins and pharmaceuticals in environmental waters (marine, brackish and freshwater) highlighting the need for the development of effective techniques to generate accurate quantitative water system profiles. In this manuscript, we reviewed in situ methods known as Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) for the collection and concentration of marine biotoxins, freshwater cyanotoxins and pharmaceuticals in environmental waters since the 1980s to present. Twelve different adsorption substrates in SPATT and 18 different sorbents in POCIS were reviewed for their ability to absorb a range of lipophilic and hydrophilic marine biotoxins, pharmaceuticals, pesticides, antibiotics and microcystins in marine water, freshwater and wastewater. This review suggests the gaps in reported studies, outlines future research possibilities and guides researchers who wish to work on water contaminates using Solid Phase Adsorption Toxin Tracking (SPATT) and Polar Organic Chemical Integrative Sampler (POCIS) technologies.
Collapse
Affiliation(s)
- Naghmeh Kamali
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- HALPIN Centre for Research & Innovation, National Maritime College of Ireland (NMCI), Munster Technological University (MTU), P43 XV65 Ringaskiddy, Ireland
| | - Feras Abbas
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| | - Mary Lehane
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| | - Michael Griew
- HALPIN Centre for Research & Innovation, National Maritime College of Ireland (NMCI), Munster Technological University (MTU), P43 XV65 Ringaskiddy, Ireland
| | - Ambrose Furey
- Mass Spectrometry Group, Department Physical Sciences, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
- CREATE (Centre for Research in Advanced Therapeutic Engineering) and BioExplore, Munster Technological University (MTU), Rossa Avenue, Bishopstown, T12 P928 Cork, Ireland
| |
Collapse
|
11
|
Yang Y, Liu S, Wang R, Li C, Tang J, Chen T, Ying GG, Chen CE. Diffusive gradients in thin films (DGT) probe for effectively sampling of per- and polyfluoroalkyl substances in waters and sediments. J Environ Sci (China) 2022; 121:90-97. [PMID: 35654519 DOI: 10.1016/j.jes.2021.09.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 09/03/2021] [Accepted: 09/07/2021] [Indexed: 06/15/2023]
Abstract
The passive sampling technique, diffusive gradients in thin films (DGT) has attracted increasing interests as an in-situ sampler for organic contaminants including per- and polyfluoroalkyl substances (PFAS). However, its effectiveness has been questioned because of the small effective sampling area (3.1 cm2). In this study, we developed a DGT probe for rapid sampling of eight PFAS in waters and applied it to a water-sediment system. It has a much larger sampling area (27 cm2) and as a result lower method quantification limits (0.15 - 0.21 ng/L for one-day deployment and 0.02 - 0.03 ng/L for one-week deployment) and much higher (by > 10 factors) sampling rate (100 mL/day) compared to the standard DGT (piston configuration). The sampler could linearly accumulate PFAS from wastewater, was sensitive enough even for a 24 hr deployment with performance comparable to grab sampling (500 mL). The DGT probe provided homogeneous sampling performance along the large exposure area. The use of the probe to investigate distributions of dissolved PFAS around the sediment-water interface was demonstrated. This work, for the first time, demonstrated that the DGT probe is a promising monitoring tool for trace levels of PFAS and a research tool for studying their distribution, migration, and fate in aquatic environments including the sediment-water interface.
Collapse
Affiliation(s)
- Yuanyuan Yang
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Sisi Liu
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Runmei Wang
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China.
| | - Cailin Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Jianhui Tang
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Tao Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Guang-Guo Ying
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Chang-Er Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China.
| |
Collapse
|
12
|
MacKeown H, Benedetti B, Scapuzzi C, Di Carro M, Magi E. A Review on Polyethersulfone Membranes in Polar Organic Chemical Integrative Samplers: Preparation, Characterization and Innovation. Crit Rev Anal Chem 2022:1-17. [PMID: 36263980 DOI: 10.1080/10408347.2022.2131374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
The membranes in polar organic chemical integrative samplers (POCIS) enclose the receiving sorbent and protect it from coming into direct contact with the environmental matrix. They have a crucial role in extending the kinetic regime of contaminant uptake, by slowing down their diffusion between the water phase and the receiving phase. The drive to improve passive sampling requires membranes with better design and enhanced performances. In this review, the preparation of standard polyethersulfone (PES) membranes for POCIS is presented, as well as methods to evaluate their composition, morphology, structure, and performance. Generally, only supplier-related morphological and structural data are provided, such as membrane type, thickness, surface area, and pore diameter. The issues related to the use of PES membranes in POCIS applications are exposed. Finally, alternative membranes to PES in POCIS are also discussed, although no better membrane has yet been developed. This review highlights the urge for more membrane characterization details and a better comprehension of the mechanisms which underlay their behavior and performance, to improve membrane selection and optimize passive sampler development.
Collapse
Affiliation(s)
- Henry MacKeown
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Barbara Benedetti
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Chiara Scapuzzi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Marina Di Carro
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| | - Emanuele Magi
- Department of Chemistry and Industrial Chemistry, University of Genoa, Genoa, Italy
| |
Collapse
|
13
|
Cao H, Bu Q, Li Q, Gao X, Xie H, Gong W, Wang X, Yang L, Tang J. Development and applications of diffusive gradients in thin films for monitoring pharmaceuticals in surface waters. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 311:119979. [PMID: 35988678 PMCID: PMC9386599 DOI: 10.1016/j.envpol.2022.119979] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 08/09/2022] [Accepted: 08/11/2022] [Indexed: 06/05/2023]
Abstract
Pharmaceutical contaminants in surface water have raised significant concerns because of their potential ecological risks. In particular, coronavirus disease 2019 (COVID-19)-related pharmaceuticals can be released to surface water and reduce environmental water quality. Therefore, reliable and robust sampling tools are required for monitoring pharmaceuticals. In this study, passive sampling devices of diffusive gradients in thin films (DGTs) were developed for sampling 35 pharmaceuticals in surface waters. The results demonstrated that hydrophilic-lipophilic balance (HLB) was more suitable for DGT-based devices compared with XAD18 and XDA1 resins. For most pharmaceuticals, the performance of the HLB-DGT devices were independent of pH (5.0-9.0), ionic strength (0.001-0.5 M), and flow velocity (0-400 rpm). The HLB-DGT devices exhibited linear pharmaceutical accumulation for 7 days, and time-weighted average concentrations provided by the HLB-DGT were comparable to those measured by conventional grab sampling. Compared to previous studies, we extended DGT monitoring to include three antiviral drugs used for COVID-19 treatment, which may inspire further exploration on identifying the effects of COVID-19 on ecological and human health.
Collapse
Affiliation(s)
- Hongmei Cao
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing, 100083, PR China
| | - Qingwei Bu
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing, 100083, PR China.
| | - Qingshan Li
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing, 100083, PR China
| | - Xiaohong Gao
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing, 100083, PR China
| | - Huaijun Xie
- Key Laboratory of Industrial Ecology and Environmental Engineering (Ministry of Education), Dalian Key Laboratory on Chemicals Risk Control and Pollution Prevention Technology, School of Environmental Science and Technology, Dalian University of Technology, Linggong Road 2, Dalian, 116024, China
| | - Wenwen Gong
- Institute of Quality Standard and Testing Technology, Beijing Academy of Agriculture and Forestry Sciences, Beijing, 100097, China
| | - Xiaoxiao Wang
- School of Chemical & Environmental Engineering, China University of Mining & Technology-Beijing, Beijing, 100083, PR China
| | - Lei Yang
- State Key Laboratory of Urban and Regional Ecology, Research Center for Eco-Environmental Science, Chinese Academy of Sciences, Beijing, 100085, China
| | - Jianfeng Tang
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, 361021, China
| |
Collapse
|
14
|
Zhu X, Jiang L, Wang Y, Ji X, Zhang D, Xu G, Wu D, Li A, Xie X. Validation and application of diffusive gradient in thin-film (DGT) equipped novel cyclodextrin polymer gels for monitoring endocrine disrupting chemicals (EDCs) and environmental risk assessment in the Taihu lake basin. ENVIRONMENTAL RESEARCH 2022; 212:113391. [PMID: 35597293 DOI: 10.1016/j.envres.2022.113391] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/25/2022] [Accepted: 04/28/2022] [Indexed: 06/15/2023]
Abstract
Taihu Lake is the most important drinking water source of the major cities in the Yangtze River Delta. The pollution of endocrine disruptors (EDCs)in Taihu Lake has been increasing recently, the accurate determination is an important guide for predicting its health risks and developing appropriate controls. Monitoring organic pollutants in water using the diffusive gradient in thin film technique (DGT) has attracted much attention due to more accuracy and convenience than the grab sampling methods. In this study, a novel cyclodextrin polymer (CDP) synthesized by the simple and green method in water was taken as an adsorbent for the binding gel. Four endocrine-disrupting chemicals (EDCs), bisphenol A (BPA), 17α-ethinylestradiol (EE2), 17β-estradiol (E2), and estriol (E3), were taken as models to determine the diffusion coefficients (4.68 × 10-6, 3.38 × 10-6, 3.34 × 10-6 and 4.31 × 10-6 cm2/s) and to test the performance of DGT, such as adsorption capacity and deployment time (1-5 day). The assembled CDP-DGT was adopted to determine four EDCs in a simulated water environment (3-9 of pH, 0.001-0.5 M of ionic strength (IS), and dissolved organic matter (DOM) of 0-20 mg/L). The ability of CDP-DGT sampling was verified in the Jiuxiang River and was carried out for a large-scale field application of in situ sampling EDCs in Taihu Lake basin. The results show that the total EDCs concentration range and the estradiol equivalent concentrations (EEQ) in Taihu Lake and its main rivers are 2.78 ng/L to 11.08 ng/L and 2.62 ng/L to 10.91 ng/L, respectively. The risk quotients (RQs) of all sampling sites in the region were greater than 1, indicating that EDCs pose a serious threat to aquatic organisms in the area. Therefore, the monitoring of EDCs in the Taihu Lake basin should be further strengthened.
Collapse
Affiliation(s)
- Xingqi Zhu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China
| | - Lu Jiang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China
| | - Yinfeng Wang
- Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang, 330031, China; Jiangxi Nanxin Environmental Protection Technology Co. LTD, Jiujiang City of Jiangxi Province, 330300, China
| | - Xiaowen Ji
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada
| | - Delin Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China
| | - Guizhou Xu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China
| | - Daishe Wu
- Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang, 330031, China
| | - Aimin Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China
| | - Xianchuan Xie
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, PR China; Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang, 330031, China; Jiangxi Nanxin Environmental Protection Technology Co. LTD, Jiujiang City of Jiangxi Province, 330300, China.
| |
Collapse
|
15
|
Gu YG, Huang HH, Gong XY, Liao XL, Dai M, Yang YF. Application of diffusive gradients in thin films to determine rare earth elements in surface sediments of Daya Bay, China: Occurrence, distribution and ecotoxicological risks. MARINE POLLUTION BULLETIN 2022; 181:113891. [PMID: 35785719 DOI: 10.1016/j.marpolbul.2022.113891] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 06/15/2023]
Abstract
Known as burgeoning contaminants, the bioavailability of rare earth elements (REEs) can be determined using diffusive gradients in thin films (DGT). As Daya Bay (South China) has been under serious anthropogenic influences, the present study examined the distribution of REEs in surface sediments and their possible ecological risks in the bay. The range of DGT-labile concentrations of REEs (∑REEs) was from 5.67 μg/L to 8.41 μg/L, with an average of 7.34 μg/L. Results of assessment of single REE toxicity revealed that the risk quotient (RQ) values of Y, Ce and Yb were >1, indicating that their potential negative impacts on the nearby environment. However, analysis of the integral toxicity of REE mixtures through assessment of probabilistic ecotoxicological risks showed that there was a negligibly low probability of toxicity of PRE surface sediments to aquatic organisms in the study area.
Collapse
Affiliation(s)
- Yang-Guang Gu
- South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China; Key laboratory of Fishery Ecology and Environment, Guangdong Province, Guangzhou 510300, China; Key Laboratory of Open-Sea Fishery Development, Ministry of Agriculture and Rural Affairs, Guangzhou 510300, China; Key Laboratory of Big Data for South, China Sea Fishery Resources and Environment, Chinese Academy of Fishery Sciences, China.
| | - Hong-Hui Huang
- South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China; Key laboratory of Fishery Ecology and Environment, Guangdong Province, Guangzhou 510300, China; Key Laboratory of Open-Sea Fishery Development, Ministry of Agriculture and Rural Affairs, Guangzhou 510300, China; Key Laboratory of Big Data for South, China Sea Fishery Resources and Environment, Chinese Academy of Fishery Sciences, China
| | - Xiu-Yu Gong
- South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China; Key laboratory of Fishery Ecology and Environment, Guangdong Province, Guangzhou 510300, China; Key Laboratory of Open-Sea Fishery Development, Ministry of Agriculture and Rural Affairs, Guangzhou 510300, China; Key Laboratory of Big Data for South, China Sea Fishery Resources and Environment, Chinese Academy of Fishery Sciences, China
| | - Xiu-Li Liao
- South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China; Key laboratory of Fishery Ecology and Environment, Guangdong Province, Guangzhou 510300, China; Key Laboratory of Open-Sea Fishery Development, Ministry of Agriculture and Rural Affairs, Guangzhou 510300, China; Key Laboratory of Big Data for South, China Sea Fishery Resources and Environment, Chinese Academy of Fishery Sciences, China
| | - Ming Dai
- South China Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Guangzhou 510300, China; Key laboratory of Fishery Ecology and Environment, Guangdong Province, Guangzhou 510300, China; Key Laboratory of Open-Sea Fishery Development, Ministry of Agriculture and Rural Affairs, Guangzhou 510300, China; Key Laboratory of Big Data for South, China Sea Fishery Resources and Environment, Chinese Academy of Fishery Sciences, China
| | - Yu-Feng Yang
- College of Life Science and Technology, Key Laboratory of Philosophy and Social Science in Guangdong Province of Jinan University, Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai), Guangzhou 510632, China
| |
Collapse
|
16
|
de Araújo EP, Caldas ED, Oliveira-Filho EC. Pesticides in surface freshwater: a critical review. ENVIRONMENTAL MONITORING AND ASSESSMENT 2022; 194:452. [PMID: 35608712 DOI: 10.1007/s10661-022-10005-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 03/28/2022] [Indexed: 05/22/2023]
Abstract
The objective of this study was to critically review studies published up to November 2021 that investigated the presence of pesticides in surface freshwater to answer three questions: (1) in which countries were the studies conducted? (2) which pesticides are most evaluated and detected? and (3) which pesticides have the highest concentrations? Using the Prisma protocol, 146 articles published from 1976 to November 2021 were included in this analysis: 127 studies used grab sampling, 10 used passive sampling, and 9 used both sampling techniques. In the 45-year historical series, the USA, China, and Spain were the countries that conducted the highest number of studies. Atrazine was the most evaluated pesticide (56% of the studies), detected in 43% of the studies using grab sampling, and the most detected in passive sampling studies (68%). The compounds with the highest maximum and mean concentrations in the grab sampling were molinate (211.38 µg/L) and bentazone (53 µg/L), respectively, and in passive sampling, they were oxyfluorfen (16.8 µg/L) and atrazine (4.8 μg/L), respectively. The levels found for atrazine, p,p'-DDD, and heptachlor in Brazil were higher than the regulatory levels for superficial water in the country. The concentrations exceeded the toxicological endpoint for at least 11 pesticides, including atrazine (Daphnia LC50 and fish NOAEC), cypermethrin (algae EC50, Daphnia and fish LC50; fish NOAEC), and chlorpyrifos (Daphnia and fish LC50; fish NOAEC). These results can be used for planning pesticide monitoring programs in surface freshwater, at regional and global levels, and for establishing or updating water quality regulations.
Collapse
Affiliation(s)
| | - Eloisa Dutra Caldas
- Toxicology Laboratory, Faculty of Health Sciences, University of Brasília - UnB, Brasília, Federal District, Brazil
| | | |
Collapse
|
17
|
Bonnaud B, Miège C, Daval A, Fauvelle V, Mazzella N. Determination of diffusion coefficients in agarose and polyacrylamide gels for 112 organic chemicals for passive sampling by organic Diffusive Gradients in Thin films (o-DGT). ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:25799-25809. [PMID: 34846659 DOI: 10.1007/s11356-021-17563-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 11/12/2021] [Indexed: 06/13/2023]
Abstract
The diffusive gradient in thin film technique was recently adapted to organic compounds. The diffusional coefficient (D) is a key parameter needed to calculate the time-weighted average concentration. In this study, two methods are used for D measurement in two gels (agarose and polyacrylamide): the diffusion cell method (Dcell) and the slice stacking method (Dstack). Thus, D were discussed and compared for 112 organic compounds, including pesticides, hormones, and pharmaceuticals. Dstack tends to be higher than Dcell. It could be explained by the presence of a non-negligible diffusive boundary layer thickness in diffusion cell. Consequently, the use of sampling rates (RS) should be more adequate to determine water concentration, for a given bulk flow velocity. Dstack also corresponds to the diffusion in gel only, allowing the determination of the maximal RS, and would be considered as a reference value that can be adjusted to in situ conditions, by applying the appropriate DBL thickness. The range and variability of D values found in the literature and obtained in this work were discussed. Relationships between D and compound physicochemical properties (molecular mass, log Dow, polar surface area, van der Waals volume) were investigated. We did not find clear and robust correlation between D and any single physicochemical property, for the set of compounds tested.
Collapse
Affiliation(s)
| | - Cécile Miège
- INRAE, UR RiverLy, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Amandine Daval
- INRAE, UR RiverLy, 5 rue de la Doua, 69100, Villeurbanne, France
| | - Vincent Fauvelle
- Mediterranean Institute of Oceanography (MIO), Aix-Marseille Univ., Toulon Univ., CNRS, IRD, 13288, Marseille, France
| | | |
Collapse
|
18
|
Martins de Barros R, Lissalde S, Guibal R, Guibaud G. Development of a multi-hormone analysis method by LC-MS/MS for environmental water application using diffusive gradient in thin films. Talanta 2022; 243:123390. [DOI: 10.1016/j.talanta.2022.123390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 03/11/2022] [Accepted: 03/12/2022] [Indexed: 11/26/2022]
|
19
|
Wang P, Challis JK, He ZX, Wong CS, Zeng EY. Effects of biofouling on the uptake of perfluorinated alkyl acids by organic-diffusive gradients in thin films passive samplers. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:242-251. [PMID: 35015011 DOI: 10.1039/d1em00436k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
While organic-diffusive gradients in thin films (o-DGT) passive samplers have been used to assess organic contaminants in water, the effects of biofouling on accurate analyte quantification by o-DGT are poorly understood. We evaluated the effects of biofouling on the uptake of six common perfluoroalkyl substances (PFAS) using a previously developed polyacrylamide-WAX (weak anion exchange) o-DGT without a filter membrane. Linear uptake (R2 > 0.91) over 21 days was observed in fouled samplers. The measured sampling rates (Rs) and accumulated masses of PFAS in pre-fouled o-DGT were significantly lower (p < 0.05, 20-39% relative error) than in control-fouled samplers. However, compared to clean o-DGT (no biofouling), the Rs of most PFAS in control-fouled samplers (i.e., those with clean diffusive and binding gels initially) were not affected by biofouling. Under flowing (∼5.8 cm s-1) and static conditions, the measured diffusive boundary layer (DBL) thicknesses for clean o-DGT were 0.016 and 0.082 cm, respectively, whereas the effective in situ biofilm thicknesses for fouled o-DGT were 0.018 and 0.14 cm, respectively. These results suggest that biofilm growth does not have significant effects on target PFAS sampling by o-DGT under typical flowing conditions (≥2 cm s-1). However, rapid surface growth of biofilm on o-DGT deployed in quiescent waters over long periods of time may exacerbate the adverse effects of biofilms, necessitating the estimation of biofilm thickness in situ. This study provides new insights for evaluating the capability of o-DGT samplers when biofilm growth can be significant.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, SK S7N 5B3, Canada
| | - Zi-Xuan He
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
- Southern California Coastal Water Research Project Authority, Costa Mesa CA 92626, USA
| | - Eddy Y Zeng
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou 511443, China.
| |
Collapse
|
20
|
Zhu X, Jiang L, Tu Y, Tian Y, Xu G, Wu D, Li A, Xie X. In situ monitoring of phthalate esters (PAEs) pollution and environmental risk assessment in Poyang Lake Basin by DGT Technology using cyclodextrin polymer as binding phase. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 808:151892. [PMID: 34826470 DOI: 10.1016/j.scitotenv.2021.151892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2021] [Revised: 11/18/2021] [Accepted: 11/18/2021] [Indexed: 06/13/2023]
Abstract
Poyang Lake is the first freshwater lake in China, which is an important drinking water source. In recent years, industrial pollution has led to the increased phthalate acid esters (PAEs) in Poyang Lake. PAEs are a class of typical endocrine disruptors that can accumulate in organisms and interfere with their secretion systems. Thus, the accurate determination of PAEs in Poyang Lake is important for health risk prediction and the development of corresponding control means. Monitoring organic pollutants in water using the diffusive gradient in thin films technique (DGT) has attracted much attention due to more accuracy and convenience than the traditional methods. This study used an inexpensive amphiphilic cyclodextrin polymer (PBCD) as the sorbent for the binding gel. This new binding gel has an ultra-high specific surface area and excellent adsorption performance. Diffusion coefficients of the five PAEs were determined, and the performance of DGT such as adsorption capacity and deployment time (1-4 days) was tested using five PAEs as models. The assembled PBCD-DGT was used to examine the performance in a complex simulated water environment. The sampling capability of PBCD-DGT was verified in Yangshan Lake, and a large-scale field application was conducted in Poyang Lake basin. The results of 11 sampling points showed that the concentration ranges of dimethyl phthalate, diethyl phthalate, diallyl phthalate, dipropyl phthalate, and dibutyl phthalate were 434-2594 ng/L, 40-314 ng/L, 80-527 ng/L, 45-308 ng/L, and ND-182 ng/L, respectively. The health risk index (HI) and ecological risk quotient (RQ) values of PAEs in the Poyang Lake watershed were far below 1, indictating a lower health and ecological risk. Considering that PAEs are bioaccumulative and persistent, it is very necessary to continue to pay attention to its pollution status and health and ecological risk changes in Poyang Lake Basin in the future.
Collapse
Affiliation(s)
- Xingqi Zhu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Lu Jiang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Yizhou Tu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Yuansong Tian
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Guizhou Xu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Daishe Wu
- Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang 330031, China
| | - Aimin Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China
| | - Xianchuan Xie
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, China; Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang 330031, China; Jiangxi Nanxin Environmental Protection Technology Co. LTD, Jiujiang City, Jiangxi Province 330300, China.
| |
Collapse
|
21
|
Zhu Y, Xu G, Wang X, Ji X, Jia X, Sun L, Gu X, Xie X. Passive sampling of chlorophenols in water and soils using diffusive gradients in thin films based on β-cyclodextrin polymers. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 806:150739. [PMID: 34619202 DOI: 10.1016/j.scitotenv.2021.150739] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 09/27/2021] [Accepted: 09/28/2021] [Indexed: 06/13/2023]
Abstract
Chlorophenols (CPs) have been listed as priority control pollutants because of their high toxicity and wide range. An In-situ monitoring technique using diffusive gradients in thin films based on porous β-cyclodextrin polymers as binding materials (CDP-DGT), was established to monitor four typical CPs, namely, 4-Chlorophenol (4-CP), 2,4-Dichlorophenol (2,4-DCP), 2,4,5-Trichlorophenol (2,4,5-TCP), 2,4,6-Trichlorophenol (2,4,6-TCP) in water and soils. The performance of CDP-DGT are stable under the conditions of pH 3.5-9.3, ionic strength 0.001-0.500 mol L-1 and dissolved organic matter concentration 0-20 mol L-1. The adsorption capacities of CDP-DGT for 4-CP, 2,4-DCP, 2,4,5-TCP, 2,4,6-TCP were 57.80 μg cm-2, 98.82 μg cm-2, 95.69 μg cm-2 and 98.91 μg cm-2, respectively. The time-average weighted concentrations of four CPs determined by CDP-DGT at Sanjiangkou wharf (Yangtze river, China) were consistent with the results of grab sampling, indicating the feasibility of CDP-DGT application in actual water. In addition, the distribution of CPs in the red soil of Kunming and paddy soil of Yixing were also studied by CDP-DGT, and the desorption kinetics in the two soils were analyzed with the DIFS model. The higher the soil organic matter content is, the more CPs are distributed in the soil solid phase. CPs in both soils can be partially resupplied to soil solution from the soil solid phase and the higher the partition coefficient for labile CPs is, the stronger the supplement capacity is.
Collapse
Affiliation(s)
- Yuanting Zhu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Guizhou Xu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Xueyao Wang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Xiaowen Ji
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada; Global Institute for Water Security, University of Saskatchewan, Saskatoon, Canada
| | - Xun Jia
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Lin Sun
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Xueyuan Gu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China
| | - Xianchuan Xie
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China; Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources Environmental & Chemical Engineering, Nanchang University, Nanchang 330031, PR China.
| |
Collapse
|
22
|
Recent nanomaterials development and application in diffusive gradients in thin-film devices. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-021-02012-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
23
|
Wang P, Du B, Smith J, Lao W, Wong CS, Zeng EY. Development and field evaluation of the organic-diffusive gradients in thin-films (o-DGT) passive water sampler for microcystins. CHEMOSPHERE 2022; 287:132079. [PMID: 34523453 DOI: 10.1016/j.chemosphere.2021.132079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 08/24/2021] [Accepted: 08/27/2021] [Indexed: 06/13/2023]
Abstract
The presence of microcystins (MCs) in waterbodies requires a simple and reliable monitoring technique to characterize better their spatiotemporal distribution and ecological risks. An organic-diffusive gradients in thin films (o-DGT) passive sampler based on polyacrylamide diffusive gel and hydrophilic-lipophilic balance (HLB) binding gel was developed for MCs in water. The mass accumulation of three MCs (MC-LR, -RR, and -YR) was linear over 10 days (R2 ≥ 0.98). Sampling rates (2.68-3.22 mL d-1) and diffusion coefficients (0.90-1.08 × 10-6 cm2 s-1) of three MCs were obtained at 20 °C. Two different passive samplers, o-DGT and the Solid Phase Adsorption Toxin Tracking device (SPATT), were co-deployed to estimate MC levels at three lakes in California, USA. Measured total MC concentrations were up to 10.9 μg L-1, with MC-LR the primary variant at a measured maximum concentration of 2.74 μg L-1. Time-weighted average MC concentrations by o-DGT were lower than grab water samples, probably because grab sampling measures both dissolved and particulate phases (i.e., MCs in cyanobacteria). Passive water samplers by design can only measure dissolved-phase MCs, which are considerably less during the cyanobacteria-laden periods observed. Both o-DGT and grab samples gave comparable results for three MC variants at low levels of MCs, e.g., <0.1 μg L-1. o-DGT showed a higher correlation with grab sampling than SPATT did. This study demonstrates that o-DGT can be effectively used for monitoring and evaluation of dissolved MCs in waters.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, Center for Environmental Microplastics Studies, School of Environment, Jinan University, Guangzhou, 511443, China
| | - Bowen Du
- Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Jayme Smith
- Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Wenjian Lao
- Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, Center for Environmental Microplastics Studies, School of Environment, Jinan University, Guangzhou, 511443, China; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA.
| | - Eddy Y Zeng
- Guangdong Key Laboratory of Environmental Pollution and Health, Center for Environmental Microplastics Studies, School of Environment, Jinan University, Guangzhou, 511443, China
| |
Collapse
|
24
|
Ji X, Challis JK, Brinkmann M. A critical review of diffusive gradients in thin films technique for measuring organic pollutants: Potential limitations, application to solid phases, and combination with bioassays. CHEMOSPHERE 2022; 287:132352. [PMID: 34826958 DOI: 10.1016/j.chemosphere.2021.132352] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 09/20/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
Diffusive gradient in thin films (DGT) for organics has received considerable attention for studying the chemical dynamics of various organic pollutants in the environment. This review investigates current limitations of DGT for organics and identifies several research gaps for future studies. The application of a protective outer filter membrane has been recommended for most DGT applications, however, important questions regarding longer lag times due to significant interaction or adsorption of specific groups of compounds on the outer membrane remain. A modified DGT configuration has been developed that uses the diffusive gel as the outer membrane without the use of an extra filter membrane, however use of this configuration, while largely successful, remains limited. Biofouling has been a concern when using DGT for metals; however, effect on the performance of DGT for organics needs to be systemically studied. Storage stability of compounds on intact DGT samplers has been assessed in select studies and that data is synthesized here. DGT has been used to describe the kinetic desorption of antibiotics from soils and biosolids based on the soil/biosolid physical-chemical characteristics, yet applications remain limited and requires further research before wide-scale adoption is recommended. Finally, DGT for organics has been rarely, albeit successfully, combined with bioassays as well as in vivo bioaccumulation studies in zebrafish. Studies using DGT combined with bioassays to predict the adverse effects of environmental mixtures on aquatic or terrestrial biota are discussed here and should be considered for future research.
Collapse
Affiliation(s)
- Xiaowen Ji
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada; Global Institute for Water Security, University of Saskatchewan, Saskatoon, Canada
| | | | - Markus Brinkmann
- School of Environment and Sustainability, University of Saskatchewan, Saskatoon, Canada; Global Institute for Water Security, University of Saskatchewan, Saskatoon, Canada; Toxicology Centre, University of Saskatchewan, Saskatoon, Canada; Centre for Hydrology, University of Saskatchewan, Saskatoon, Canada.
| |
Collapse
|
25
|
Verhagen R, Tscharke BJ, Clokey J, Gerber C, Ghetia M, Kaserzon SL, Thomas KV, Mueller JF. Multisite Calibration of a Microporous Polyethylene Tube Passive Sampler for Quantifying Drugs in Wastewater. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:12922-12929. [PMID: 34528434 DOI: 10.1021/acs.est.1c02900] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Passive sampling approaches to monitor licit and illicit drugs of concern in wastewater shows promise as a supplementary sampling technique to grab sampling when conventional composite autosampling may not be possible. Recent studies have assessed the applicability of passive sampling at a single wastewater treatment plant (WWTP). However, it remains unknown whether a single-site calibration can be applied to other WWTPs. This study evaluated the in situ calibration of microporous polyethylene tube passive samplers (MPTs) against simultaneously collected composite samples for 22 different WWTPs. Samples were analyzed for methylamphetamine, amphetamine, hydroxycotinine, cotinine, benzoylecgonine, 3,4-methylenedioxymethamphetamine, and noroxycodone. Estimated rates of chemical uptake (sampling rates) were calculated using the mass accumulated in the samplers, the concentration measured in composite samples, and the duration of deployment. The estimated sampling rates were consistent between WWTPs (>90% within a factor of two) and ranged from 5 mL day-1 (amphetamine) to 9 mL day-1 (noroxycodone). The samplers were effective at estimating analyte concentrations, with 77% of results having a normalized difference to 24 h composite samples of below 30%. Our study suggests that MPT passive samplers provide a tool for the spatiotemporal monitoring of drug use where automated integrative sampling techniques may not be feasible.
Collapse
Affiliation(s)
- Rory Verhagen
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Benjamin J Tscharke
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Joseph Clokey
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Cobus Gerber
- Health and Biomedical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, South Australia 5001, Australia
| | - Maulik Ghetia
- Health and Biomedical Innovation, UniSA: Clinical and Health Sciences, University of South Australia, Adelaide, South Australia 5001, Australia
| | - Sarit L Kaserzon
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Kevin V Thomas
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| | - Jochen F Mueller
- Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia
| |
Collapse
|
26
|
Li H, Qi S, Li X, Qian Z, Chen W, Qin S. Tetrafluoroterephthalonitrile-crosslinked β-cyclodextrin polymer as a binding agent of diffusive gradients in thin-films for sampling endocrine disrupting chemicals in water. CHEMOSPHERE 2021; 280:130774. [PMID: 33971412 DOI: 10.1016/j.chemosphere.2021.130774] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/23/2021] [Accepted: 04/27/2021] [Indexed: 06/12/2023]
Abstract
β-Cyclodextrin (β-CD) is an inexpensive and reproducible material derived from corn starch. It is possible that tetrafluoroterephthalonitrile-crosslinked β-cyclodextrin polymer (TFN-CD), a cheap but efficient adsorbent, could be a suitable binding agent for use in the passive sampling technique, diffusive gradients in thin-films (DGT). Herein, the TFN-CD binding gel was prepared and then evaluated as the binding phase of DGT to sample six endocrine disrupting chemicals (EDCs) in water. The TFN-CD dispersed uniformly in the binding gel due to its hydrophilicity. The quantitative recoveries (99.3%-106%) of EDCs from the TFN-CD binding gel could be conveniently achieved by ultrasonic extraction using 5 mL methanol for 10 min. Compared with the excellent HLB (hydrophilic-lipophilic-balanced resin) binding gel, the TFN-CD binding gel had comparable or even faster adsorption kinetics, although the equilibrium adsorption capacity was slightly lower. The effective adsorption capacities of TFN-CD-based DGT (TFN-CD-DGT) were roughly estimated to enable a 7-days deployment in EDC solution of 25.7-30.0 μg L-1. Studies of influencing factors showed that the ionic strength (0-0.5 M), pH (3.73-9.13), dissolved organic matter (0-20 mg L-1) and long-term storage (204 days) had negligible influence on the performance of TFN-CD-DGT. Finally, the TFN-CD-DGT was successfully used to record sudden increases in bulk concentrations during simulated discharge events in pond water. These results demonstrate that TFN-CD is a suitable binding agent for sampling of EDCs, and the low cost of TFN-CD could be conducive to the application of DGT in large-scale sampling.
Collapse
Affiliation(s)
- Huan Li
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China; School of Environmental Studies, China University of Geosciences, Wuhan, 430074, China
| | - Shihua Qi
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China
| | - Xiaoshui Li
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China.
| | - Zhe Qian
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China
| | - Wei Chen
- School of Environmental Studies, China University of Geosciences, Wuhan, 430074, China
| | - Shibin Qin
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan, 430074, China
| |
Collapse
|
27
|
Chaves-Barquero LG, Humeniuk BW, Luong KH, Cicek N, Wong CS, Hanson ML. Crushed recycled glass as a substrate for constructed wetland wastewater treatment: a case study of its potential to facilitate pharmaceutical removal. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:52306-52318. [PMID: 34003437 DOI: 10.1007/s11356-021-14483-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Accepted: 05/14/2021] [Indexed: 06/12/2023]
Abstract
The use of recycled glass as a substrate for constructed wetlands was assessed through two studies. The first study examined the dissipation of atenolol, carbamazepine, and sulfamethoxazole in mesocosm-modeled wetlands using glass or limestone gravel as substrates, with or without cattails (Typha spp.). Following pseudo-first-order kinetics, atenolol dissipated the fastest from the water surface of the mesocosms (t1/2~1 day), followed by sulfamethoxazole (t1/2~14 days), and carbamazepine (t1/2~48 days), with no significant differences across treatments. Increased half-lives were observed at greater depth, likely due to light screening. A Monte Carlo sensitivity analysis diagnosed sunlight absorption rates and second-order hydroxyl-mediated indirect photolysis rates to be the main sources of uncertainty in our dissipation rate estimates, compared to our observed rates. The second study examined in situ pharmaceutical removal in tertiary pilot-scale subsurface filters made of crushed recycled glass or sand in a wastewater treatment facility in Manitoba, Canada. Glass and sand showed no significant differences for pharmaceutical removals; atenolol and metoprolol were removed below limits of detection, while carbamazepine and sulfamethoxazole persisted over a retention time of 24 h. Overall, recycled glass performed similarly to traditional substrates for wetland-based wastewater treatment.
Collapse
Affiliation(s)
- Luis G Chaves-Barquero
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada.
- Escuela de Química, Instituto Tecnológico de Costa Rica, Cartago, 30101, Costa Rica.
| | - Braedon W Humeniuk
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| | - Kim H Luong
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
| | - Nazim Cicek
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB, R3T 5V6, Canada
| | - Charles S Wong
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
- Escuela de Química, Instituto Tecnológico de Costa Rica, Cartago, 30101, Costa Rica
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
- Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Mark L Hanson
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| |
Collapse
|
28
|
Liu S, Chen S, Li X, Yue Y, Li J, Williams PN, Wang Z, Li C, Yang Y, Ying GG, Chen CE. Development and application of diffusive gradients in thin-films for in situ sampling of the bitterest chemical - denatonium benzoate in waters. JOURNAL OF HAZARDOUS MATERIALS 2021; 418:126393. [PMID: 34329009 DOI: 10.1016/j.jhazmat.2021.126393] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/08/2021] [Accepted: 06/09/2021] [Indexed: 06/13/2023]
Abstract
Denatonium benzoate (DB), a commonly used bitter agent in numerous products, has recently been recognized as a waterborne contaminant due to concern about its potential persistence, mobility and toxicity (PMT). However, its occurrence, levels and fate in global aquatic environments are largely unknown. In this study, a new sampling method, based on diffusive gradients in thin films (DGT) with mixed-mode cation exchange (MCX) as the binding agent, was developed for measuring DB in waters. MCX shows a rapid adsorption and high capacity for DB. DB is linearly accumulated by MCX-DGT. pH (6-8), ionic strength (0.01-0.5 M), or DOM (0-10 M) do not show any significant effect on the MCX-DGT performance, confirming its reliability. The DGT measurements in a wastewater treatment plant (WWTP) are comparable to those by paralleled grab sampling. The field results suggest DB is persistent in WWTPs and could be a potential domestic wastewater indicator. Therefore, MCX-DGT is a promising technique for understanding the environmental occurrence, levels and fate of DB. This is a first report of using DGT for DB monitoring and of DB occurrence in Chinese environments. Further exploration of DGT as a reliable passive monitoring tool for a wide range of PMT substances in different applications is warranted.
Collapse
Affiliation(s)
- Sisi Liu
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Shibao Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Xiaohao Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Yubo Yue
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Jinling Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Paul N Williams
- Institute for Global Food Security, Queen's University Belfast, Biological Sciences, 19 Chlorine Gardens, Belfast BT9 5DL, UK
| | - Zhanyun Wang
- Institute of Environmental Engineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Cailin Li
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Yuanyuan Yang
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Guang-Guo Ying
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China
| | - Chang-Er Chen
- Environmental Research Institute/School of Environment, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety & MOE Key Laboratory of Theoretical Chemistry of Environment, South China Normal University, Guangzhou 510006, China.
| |
Collapse
|
29
|
Amato ED, Pfeiffer F, Estoppey N, Subotic D, Herweyers L, Breugelmans T, Weyn M, Du Bois E, Dardenne F, Covaci A, Town RM, Blust R. Field application of a novel active-passive sampling technique for the simultaneous measurement of a wide range of contaminants in water. CHEMOSPHERE 2021; 279:130598. [PMID: 33901895 DOI: 10.1016/j.chemosphere.2021.130598] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 04/08/2021] [Accepted: 04/12/2021] [Indexed: 06/12/2023]
Abstract
A first test of the field capabilities of a novel in situ sampling technique combining active and passive sampling (APS) was conducted in the sea. The proof-of-concept device uses a pump to draw water into a diffusion cell where dissolved target substances are accumulated onto sorbents which are selective for different classes of contaminants (i.e., metal cations, polar and non-polar organic compounds), simultaneously. A controlled laminar flow established in the diffusion cell enables measurements of contaminant concentrations that are fully independent from the hydrodynamic conditions in the bulk solution. APS measurements were consistent with those obtained using conventional passive sampling techniques such as organic diffusive gradients in thin films (o-DGT) and silicone rubber (SR) samplers (generally < 40% difference), taking into account the prevailing hydrodynamic conditions. The use of performance reference compounds (PRC) for hydrophobic contaminants provided additional information. Field measurements of metal ions in seawater showed large variability due to issues related to the device configuration. An improved field set-up deployed in supplementary freshwater mesocosm experiments provided metal speciation data that was consistent with passive sampling measurements (DGT), taking into account the hydrodynamic conditions. Overall, the results indicate that the APS technique provides a promising approach for the determination of a wide range of contaminants simultaneously, and independently from the hydrodynamic conditions in the bulk solution.
Collapse
Affiliation(s)
- Elvio D Amato
- Systemic Physiological and Ecotoxicological Research (SPHERE), Department of Biology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium.
| | - Fabienne Pfeiffer
- School of Criminal Justice, University of Lausanne, Batochime, 1015, Lausanne, Switzerland
| | - Nicolas Estoppey
- School of Criminal Justice, University of Lausanne, Batochime, 1015, Lausanne, Switzerland
| | - Dragan Subotic
- Internet and Data Lab (IDLab), University of Antwerp - Imec, Belgium
| | - Laure Herweyers
- Department of Product Development, Faculty of Design Sciences, University of Antwerp, 2000, Antwerpen, Belgium
| | - Tom Breugelmans
- Research Group Applied Electrochemistry & Catalysis (ELCAT), University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Belgium
| | - Maarten Weyn
- Internet and Data Lab (IDLab), University of Antwerp - Imec, Belgium
| | - Els Du Bois
- Department of Product Development, Faculty of Design Sciences, University of Antwerp, 2000, Antwerpen, Belgium
| | - Freddy Dardenne
- Systemic Physiological and Ecotoxicological Research (SPHERE), Department of Biology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| | - Adrian Covaci
- Toxicological Center, University of Antwerp, Universiteitsplein 1, 2610, Wilrijk, Belgium
| | - Raewyn M Town
- Systemic Physiological and Ecotoxicological Research (SPHERE), Department of Biology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| | - Ronny Blust
- Systemic Physiological and Ecotoxicological Research (SPHERE), Department of Biology, University of Antwerp, Groenenborgerlaan 171, 2020, Antwerp, Belgium
| |
Collapse
|
30
|
Fang Z, Li Y, Li Y, Yang D, Zhang H, Jones KC, Gu C, Luo J. Development and Applications of Novel DGT Passive Samplers for Measuring 12 Per- and Polyfluoroalkyl Substances in Natural Waters and Wastewaters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:9548-9556. [PMID: 33710858 DOI: 10.1021/acs.est.0c08092] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Extensive and long-term use of per- and polyfluoroalkyl substances (PFASs) has caused their widespread distribution in aquatic systems. A new diffusive gradients in thin-films (DGT) passive sampling method based on weak anion exchanger (WAX) binding layer is developed here for monitoring five perfluoroalkyl carboxylic acids (PFCAs), five perfluoroalkanesulfonic acids (PFSAs) and two PFASs (6:2 FTSA and GenX) in waters. Performance of WAX-DGTs was independent of environmental conditions, namely pH (3.03-8.96), ionic strength (1-500 mM), and DOM content (4-30 mg L-1). Diffusion coefficients (D) of the 12 PFASs in the diffusive gels were measured, 9 for the first time. Linear correlations between D and perfluoroalkyl chain lengths (CF2) were established to obtain D for congener chemicals with the similar functional group and structure. The binding capacity of the WAX-DGT sampler was at least 440 μg PFASs per sampler, sufficient for applications in waters across a wide range of conditions and PFASs concentrations. Successful applications of WAX based DGT samplers in a wastewater treatment plant (WWTP) and three rivers has demonstrated that DGT is a powerful tool for monitoring, surveillance and research of these 12 PFASs in aquatic systems, and can be extended to wider suites of PFs in future.
Collapse
Affiliation(s)
- Zhou Fang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| | - Yuan Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| | - Yanying Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| | - Danxing Yang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Kevin C Jones
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Cheng Gu
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| | - Jun Luo
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, P. R. China
| |
Collapse
|
31
|
Liu X, Zhang R, Cheng H, Khorram MS, Zhao S, Tham TT, Tran TM, Minh TB, Jiang B, Jin B, Zhang G. Field evaluation of diffusive gradients in thin-film passive samplers for wastewater-based epidemiology. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 773:145480. [PMID: 33592478 DOI: 10.1016/j.scitotenv.2021.145480] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 01/24/2021] [Accepted: 01/24/2021] [Indexed: 06/12/2023]
Abstract
There is a need for a simple water sampling technique to enable routine monitoring of community drug consumption through wastewater-based epidemiology (WBE). This study investigates the potential use of diffusive gradients in thin films to sample organic compounds (o-DGT) for WBE. Three types of resin gels (HLB, XAD 18, and XDA-1) within o-DGT samplers each were deployed in triplicate at the inlets of two sewage treatment plants of Southern Asian cities. The target compounds included 15 illicit drugs and 18 antibiotics. A comprehensive evaluation was undertaken regarding each resin's ability to accumulate the target compounds and accuracy by comparing active samples. The organic compounds accumulated on each resin gel were characterised at the molecular level using Fourier transform ion-cyclotron-resonance mass spectrometry (FT-ICR MS). The results showed that the HLB resin performed better than the XAD 18 and XDA-1 resins. Based on calculations using the HLB-DGT data, methamphetamine and heroin were the two most popular illicit drugs consumed among the studied populations, and were followed by ketamine and codeine, which agreed well with the authoritative reports and reference data. The total drug consumption in Hanoi was one order of magnitude higher than that in Guangzhou, thus implying a probably more serious drug situation in the former. Overall, the findings of this study demonstrate that o-DGT passive samplers are a promising tool for WBE studies, particularly at WWTPs or in urban streams where an automatic sampler for taking composite water samples is absent.
Collapse
Affiliation(s)
- Xin Liu
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China; Guangdong Provincial Key Laboratory of Psychoactive Substances Monitoring and Safety, Guangzhou, China
| | - Ruiling Zhang
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Hao Cheng
- Nanjing Vision Environmental Science & Technology CO., LTD., Nanjing, Jiangsu, China
| | - Mahdi Safaei Khorram
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Shizhen Zhao
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Trinh Thi Tham
- Faculty of Environment, Hanoi University of Natural Resources and Environment, 41A Phu Dien, North-Tu Liem, Hanoi, Vietnam
| | - Tri Manh Tran
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Vietnam
| | - Tu Binh Minh
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, 19 Le Thanh Tong, Hanoi 10000, Vietnam
| | - Bin Jiang
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Biao Jin
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China
| | - Gan Zhang
- State Key Laboratory of Organic Geochemistry and Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou, China; Guangdong Provincial Key Laboratory of Psychoactive Substances Monitoring and Safety, Guangzhou, China.
| |
Collapse
|
32
|
Caban M, Lis H, Stepnowski P. Limitations of Integrative Passive Samplers as a Tool for the Quantification of Pharmaceuticals in the Environment - A Critical Review with the Latest Innovations. Crit Rev Anal Chem 2021; 52:1386-1407. [PMID: 33673780 DOI: 10.1080/10408347.2021.1881755] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
This review starts with a presentation of the theory of kinetic uptake by passive sampling (PS), which is traditionally used to distinguish between integrative and equilibrium samplers. Demonstrated limitations of this model for the passive sampling of pharmaceuticals from water were presented. Most notably, the contribution of the protective membrane in the resistance to mass transfer of lipophilic analytes and the well documented effect of external parameters on sampling rates contributed to the greatest uncertainty in PS application. The diffusion gradient in thin layer (DGT) technique seems to reduce the effect of external parameters (e.g., flow rate) to some degree. The laboratory-determined integrative uptake periods over defined sampler deployments was compared, and the discrepancy found suggests that the most popular Polar Organic Chemical Integrative Sampler (POCIS) could in some cases utilized as an equilibrium sampler. This assertion is supported by own calculations for three pharmaceuticals with extremely different lipophilic characters. Finally, the reasons performance reference compounds (PRCs) are not recommended for the reduction in uncertainty of the TWAC found by adsorptive samplers were presented. It was concluded that techniques of passive sampling of pharmaceuticals need a new uptake model to fit the current situation.
Collapse
Affiliation(s)
- Magda Caban
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, Gdańsk, Poland
| | - Hanna Lis
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, Gdańsk, Poland
| | - Piotr Stepnowski
- Department of Environmental Analysis, Faculty of Chemistry, University of Gdansk, Gdańsk, Poland
| |
Collapse
|
33
|
Nguyen MT, De Baat ML, Van Der Oost R, Van Den Berg W, De Voogt P. Comparative field study on bioassay responses and micropollutant uptake of POCIS, Speedisk and SorbiCell polar passive samplers. ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY 2021; 82:103549. [PMID: 33246138 DOI: 10.1016/j.etap.2020.103549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Revised: 11/06/2020] [Accepted: 11/09/2020] [Indexed: 06/11/2023]
Abstract
Routine water quality monitoring is generally performed with chemical analyses of grab samples, which has major limitations. First, snapshot samples will not give a good representation of the water quality. Second, it is not sufficient to analyze only a limited number of (priority) pollutants. These limitations can be circumvented by an alternative environmental risk assessment that combines time-integrated passive sampling (PS) with effect-based methods. This study aimed to select which of three polar PS devices was best suited for effect-based monitoring strategies. In the first part of this study, Speedisk, SorbiCell and POCIS polar PS devices were compared by simultaneous deployment at five sites. Chemical analyses of 108 moderately polar compounds (-1.82 < log D < 6.28) revealed that highest number of compounds, with the widest range of log KOW, log D and pKa, were detected in extracts of POCIS, followed by Speedisk. SorbiCell samplers accumulated the lowest numbers and concentrations of compounds, so they were not further investigated. In a follow-up study, bioassay responses were compared in extracts of POCIS and Speedisk devices deployed at eight sites. The passive sampler extracts were subjected to bioassays for non-specific toxicity, endocrine disruption, and antibiotics activities. More frequent and higher responses were induced by POCIS extracts, leading to more exceedances of effect-based trigger values for environmental risks. As POCIS outperformed Speedisk, it is better suited as PS device targeting polar compounds for semi-quantitative effect-based water quality monitoring.
Collapse
Affiliation(s)
- M Thao Nguyen
- Waterproef Laboratory, Department of Research & Validation, Edam, the Netherlands.
| | - Milo L De Baat
- Institute for Biodiversity and Ecosystem Dynamics, Department of Freshwater and Marine Ecology, University of Amsterdam, the Netherlands
| | - Ron Van Der Oost
- Waternet Institute for the Urban Water Cycle, Department of Technology, Research and Engineering, Amsterdam, the Netherlands
| | - Willie Van Den Berg
- Waterproef Laboratory, Department of Research & Validation, Edam, the Netherlands
| | - Pim De Voogt
- Institute for Biodiversity and Ecosystem Dynamics, Department of Freshwater and Marine Ecology, University of Amsterdam, the Netherlands; KWR Water Research Institute, Nieuwegein, the Netherlands
| |
Collapse
|
34
|
Vrana B, Urík J, Fedorova G, Švecová H, Grabicová K, Golovko O, Randák T, Grabic R. In situ calibration of polar organic chemical integrative sampler (POCIS) for monitoring of pharmaceuticals in surface waters. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 269:116121. [PMID: 33272798 DOI: 10.1016/j.envpol.2020.116121] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 11/14/2020] [Accepted: 11/16/2020] [Indexed: 06/12/2023]
Abstract
POCIS is the most widely applied passive sampler of polar organic substances, because it was one of the first commercially available samplers for that purpose on the market, but also for its applicability for a wide range of substances and conditions. Its main weakness is the variability of sampling performance with exposure conditions. In our study we took a pragmatic approach and performed in situ calibration for a set of 76 pharmaceuticals and their metabolites in five sampling campaigns in surface water, covering various temperature and flow conditions. In individual campaigns, RS were calculated for up to 47 compounds ranging from 0.01 to 0.63 L d-1, with the overall median value of 0.10 L d-1. No clear changes of RS with water temperature or discharge could be found for any of the investigated substances. The absence of correlation of experimental RS with physical-chemical properties in combination with the lack of mechanistic understanding of compound uptake to POCIS implies that practical estimation of aqueous concentrations from uptake in POCIS depends on compound-specific experimental calibration data. Performance of POCIS was compared with grab sampling of water in seven field campaigns comprising multiple sampling sites, where sampling by both methods was done in parallel. The comparison showed that for 25 of 36 tested compounds more than 50% of POCIS-derived aqueous concentrations did not differ from median of grab sampling values more than by a factor of 2. Further, for 30 of 36 compounds, more than 80% of POCIS data did not differ from grab sampling data more than by a factor of 5. When accepting this level of accuracy, in situ derived sampling rates are sufficiently robust for application of POCIS for identification of spatial and temporal contamination trends in surface waters.
Collapse
Affiliation(s)
- Branislav Vrana
- Masaryk University, Faculty of Science, Centre RECETOX, Kamenice 753/5, 625 00, Brno, Czech Republic.
| | - Jakub Urík
- Masaryk University, Faculty of Science, Centre RECETOX, Kamenice 753/5, 625 00, Brno, Czech Republic
| | - Ganna Fedorova
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Helena Švecová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Kateřina Grabicová
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Oksana Golovko
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Tomáš Randák
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| | - Roman Grabic
- University of South Bohemia in České Budějovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Zátiší 728/II, CZ-389 25, Vodňany, Czech Republic
| |
Collapse
|
35
|
Wang P, Challis JK, Luong KH, Vera TC, Wong CS. Calibration of organic-diffusive gradients in thin films (o-DGT) passive samplers for perfluorinated alkyl acids in water. CHEMOSPHERE 2021; 263:128325. [PMID: 33297256 DOI: 10.1016/j.chemosphere.2020.128325] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/08/2020] [Accepted: 09/10/2020] [Indexed: 06/12/2023]
Abstract
The application of the organic-diffusive gradients in thin films (o-DGT) passive sampling technique for the monitoring of per- and polyfluoroalkyl substances (PFAS) in the environment is still limited. Six common PFAS with different chain lengths were evaluated in water by o-DGT. Measured diffusion coefficients (D) in agarose and polyacrylamide diffusive gels ranged from 4.55-8.63 × 10-6 cm2 s-1 and 3.85-7.00 × 10-6 cm2 s-1 at 23 °C, respectively. Experimental sampling rates (Rs) for both agarose- and polyacrylamide-WAX sampler configurations were within 22% relative error of D-based Rs for four of the PFAS. Larger differences for perfluorobutanesulfonic acid (PFBS) and perfluoroundecanoic acid (PFUnDA) ranged from 36% to 56%. In general, in-situ Rs can be predicted using measured D-values for perfluorinated alkyl acids. The mass accumulation of six PFAS in two o-DGT configurations was linear over 21 days (R2 ≥ 0.97). Diffusion and uptake of o-DGT depended on the gel type and specific PFAS. Field demonstrations of o-DGT with WAX and HLB binding gels and polyacrylamide diffusive gels (not prone to biodegradation) found 0.3-19.5 ng L-1 of PFAS in rivers near industrial areas around Guangzhou and Foshan, China, with no apparent differences between the two co-deployed samplers. This study demonstrates that the configurations of o-DGT tested provide a cost-effective monitoring tool for measuring perfluorinated alkyl acids in aquatic systems, in particular the four PFAS for which reasonable correlations were observed.
Collapse
Affiliation(s)
- Po Wang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA
| | - Jonathan K Challis
- Toxicology Centre, University of Saskatchewan, Saskatoon, SK, S7N 5B3, Canada
| | - Kim H Luong
- Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada
| | - Trisha C Vera
- Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada
| | - Charles S Wong
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA; Richardson College for the Environment, University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada.
| |
Collapse
|
36
|
Ren S, Tan F, Wang Y, Zhao H, Zhang Y, Zhai M, Chen J, Wang X. In situ measurement of synthetic musks in wastewaters using diffusive gradients in thin film technique. WATER RESEARCH 2020; 185:116239. [PMID: 32739702 DOI: 10.1016/j.watres.2020.116239] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 07/23/2020] [Accepted: 07/26/2020] [Indexed: 06/11/2023]
Abstract
Synthetic musks (SMs) are used extensively in household and personal care products and have acted significant concerns due to their environmental impacts and potential health effects. Here, we present a passive sampling approach based on diffusive gradients in thin films (DGT) for in situ measurement of SMs in urban wastewaters. XAD-2 binding gel, which has a rapid binding rate and high elution efficiency, was used in DGT device for the accumulation of six polycyclic musks and three nitro musks. The diffusion coefficients (D and DNL) of the SMs through agarose gel without and with a nylon filter membrane were 3.37-4.49 and 1.48-4.41 ×10-6cm2 s-1. The filter membrane caused an ~3 h lag phase and slowed the diffusion rates of the SMs through the diffusive phase. Solution pH (4.30-8.92), ionic strength (0.0001-0.5 M) and dissolved organic matter (0-20 mg L-1) showed no obvious influence on uptake of the SMs in DGT. The measured average SM concentrations in the effluent of wastewater treatment plants ranged from 0.45-696 ng/L for DGT deployment, without obvious membrane biofouling, and they were comparable to the concentrations determined by grab sampling. These results confirmed that the present method is reliable and convenient for in situ measurement of semivolatile hydrophobic SMs in complicated waters and is an available tool to investigate the environmental behaviors of SMs in the environment.
Collapse
Affiliation(s)
- Suyu Ren
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Feng Tan
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China.
| | - Yan Wang
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Hongxia Zhao
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Yiwen Zhang
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Mingyan Zhai
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Jingwen Chen
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology, Dalian University of Technology, Dalian 116024, China
| | - Xiaochun Wang
- Anshan Normal University, Department of Chemistry & Life Science, Anshan 114005, China.
| |
Collapse
|
37
|
Chen CE, Liu YS, Dunn R, Zhao JL, Jones KC, Zhang H, Ying GG, Sweetman AJ. A year-long passive sampling of phenolic endocrine disrupting chemicals in the East River, South China. ENVIRONMENT INTERNATIONAL 2020; 143:105936. [PMID: 32659529 DOI: 10.1016/j.envint.2020.105936] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2020] [Revised: 06/26/2020] [Accepted: 06/28/2020] [Indexed: 06/11/2023]
Abstract
The occurrence of endocrine disrupting chemicals (EDCs) in the aquatic environment is a global concern. In this study, we employed two different passive samplers Diffusive Gradients in Thin-films (DGT) and Chemcatcher for in situ measurement of 8 phenolic EDCs in the East River of the Pearl River system over one-year. These data were assessed alongside results from traditional grab sampling. Six chemicals (4tOP, 4NP, BPA, E1, EE2 and DES) were regularly detected in the water samples, of which the three phenols (i.e. 4tOP, 4NP and BPA) were in all samples and at high concentrations (0.4-1040 ng/L for 4tOP, 2.6-58500 ng/L for NP and 11.4-123300 ng/L for BPA). Fewer target chemicals were detected in both passive samplers, with only 4tOP, 4NP and BPA found in most samplers; E1 and DES were occasionally measurable above detection limits. The higher (by about a factor of 2-3) measurements provided by DGT compared to Chemcatcher could be attributed to the effect of the diffusive boundary layer on Chemcatcher uptake or the strong adsorption of target chemicals on the Chemcatcher PES filter. The temporal trends of EDC monthly loadings indicated that they were from different sources and that WWTPs were not effective in EDC removal and/or there was still some untreated wastewater discharged into the rivers.
Collapse
Affiliation(s)
- Chang-Er Chen
- Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety, South China Normal University, Guangzhou 510006, China; School of Environment, MOE Key Laboratory of Environmental Theoretical Chemistry, South China Normal University, Guangzhou 510006, China
| | - You-Sheng Liu
- Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety, South China Normal University, Guangzhou 510006, China; School of Environment, MOE Key Laboratory of Environmental Theoretical Chemistry, South China Normal University, Guangzhou 510006, China
| | - Ricky Dunn
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Jian-Liang Zhao
- Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety, South China Normal University, Guangzhou 510006, China; School of Environment, MOE Key Laboratory of Environmental Theoretical Chemistry, South China Normal University, Guangzhou 510006, China
| | - Kevin C Jones
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Guang-Guo Ying
- Environmental Research Institute, Guangdong Provincial Key Laboratory of Chemical Pollution and Environmental Safety, South China Normal University, Guangzhou 510006, China; School of Environment, MOE Key Laboratory of Environmental Theoretical Chemistry, South China Normal University, Guangzhou 510006, China.
| | - Andrew J Sweetman
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom.
| |
Collapse
|
38
|
Li Q, Liu J, Gadd GM. Fungal bioremediation of soil co-contaminated with petroleum hydrocarbons and toxic metals. Appl Microbiol Biotechnol 2020; 104:8999-9008. [PMID: 32940735 PMCID: PMC7567682 DOI: 10.1007/s00253-020-10854-y] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 08/11/2020] [Accepted: 08/23/2020] [Indexed: 11/27/2022]
Abstract
Abstract Much research has been carried out on the bacterial bioremediation of soil contaminated with petroleum hydrocarbons and toxic metals but much less is known about the potential of fungi in sites that are co-contaminated with both classes of pollutants. This article documents the roles of fungi in soil polluted with both petroleum hydrocarbons and toxic metals as well as the mechanisms involved in the biotransformation of such substances. Soil characteristics (e.g., structural components, pH, and temperature) and intracellular or excreted extracellular enzymes and metabolites are crucial factors which affect the efficiency of combined pollutant transformations. At present, bioremediation of soil co-contaminated with petroleum hydrocarbons and toxic metals is mostly focused on the removal, detoxification, or degradation efficiency of single or composite pollutants of each type. Little research has been carried out on the metabolism of fungi in response to complex pollutant stress. To overcome current bottlenecks in understanding fungal bioremediation, the potential of new approaches, e.g., gradient diffusion film technology (DGT) and metabolomics, is also discussed. Key points • Fungi play important roles in soil co-contaminated with TPH and toxic metals. • Soil characteristics, enzymes, and metabolites are major factors in bioremediation. • DGT and metabolomics can be applied to overcome current bottlenecks.
Collapse
Affiliation(s)
- Qianwei Li
- State Key Laboratory of Heavy Oil Processing, State Key Laboratory of Petroleum Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China.
| | - Jicheng Liu
- State Key Laboratory of Heavy Oil Processing, State Key Laboratory of Petroleum Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China
| | - Geoffrey Michael Gadd
- State Key Laboratory of Heavy Oil Processing, State Key Laboratory of Petroleum Pollution Control, China University of Petroleum-Beijing, Beijing, 102249, China.
- Geomicrobiology Group, School of Life Sciences, University of Dundee, Dundee, Scotland, DD1 5EH, UK.
| |
Collapse
|
39
|
Wang R, Biles E, Li Y, Juergens MD, Bowes MJ, Jones KC, Zhang H. In Situ Catchment Scale Sampling of Emerging Contaminants Using Diffusive Gradients in Thin Films (DGT) and Traditional Grab Sampling: A Case Study of the River Thames, UK. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:11155-11164. [PMID: 32797751 DOI: 10.1021/acs.est.0c01584] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The in situ passive sampling technique, diffusive gradients in thin films (DGT), confronts many of the challenges associated with current sampling methods used for emerging contaminants (ECs) in aquatic systems. This study compared DGT and grab sampling for their suitability to screen and monitor ECs at the catchment scale in the River Thames system (U.K.) and explored their sources and environmental fate. The ubiquitous presence of endocrine disrupting chemicals, parabens, and their metabolites is of concern. This study is the first to report organophosphate esters (OPEs) in the study area. TEP (summer 13-160 and winter 18-46, ng/L) and TCPP (summer 242-4282 and winter 215-854, ng/L) were the main OPEs. For chemicals which were relatively stable in the rivers, DGT and grab sampling were in good agreement. For chemicals which showed high variation in water bodies, DGT provided a better integral of loadings and exposure than grab sampling. DGT was not as sensitive as grab sampling under the procedures employed here, but there are several options to improve it to give comparable/better performance. DGT samples require shorter preparation time for analysis in the laboratory than grab samples. Overall, DGT can be a powerful tool to characterize ECs throughout a large dynamic water system.
Collapse
Affiliation(s)
- Runmei Wang
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Emma Biles
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Yanying Li
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | | | - Michael J Bowes
- Centre for Ecology and Hydrology, Wallingford, Oxon OX10 8BB, U.K
| | - Kevin C Jones
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster, LA1 4YQ, U.K
| |
Collapse
|
40
|
Sampling Rate of Polar Organic Chemical Integrative Sampler (POCIS): Influence Factors and Calibration Methods. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10165548] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (Rs), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, the Rs values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on the Rs are analyzed in detail from aspects of impact dependence and mechanisms. The calibration methods of the Rs under laboratory and in situ conditions are summarized. This review offers supplementary information on comprehensive understanding of mechanism and application of the POCIS. Nevertheless, the Rs were impacted by a combined effect of solute–sorbent–membrane–solution, and the influence extent of each variable was still unclear. On this basis, the ongoing challenges are proposed for the future application of the POCIS in the actual environment, for instance, the need for this device to be improved in terms of quantitative methods for more accurate measurement of the Rs.
Collapse
|
41
|
Gravell A, Fones GR, Greenwood R, Mills GA. Detection of pharmaceuticals in wastewater effluents-a comparison of the performance of Chemcatcher® and polar organic compound integrative sampler. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:27995-28005. [PMID: 32405945 PMCID: PMC7334249 DOI: 10.1007/s11356-020-09077-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2020] [Accepted: 04/27/2020] [Indexed: 05/16/2023]
Abstract
Chemcatcher® and POCIS passive sampling devices are widely used for monitoring polar organic pollutants in water. Chemcatcher® uses a bound Horizon Atlantic™ HLB-L sorbent disk as receiving phase, whilst the POCIS uses the same material in the form of loose powder. Both devices (n = 3) were deployed for 21 days in the final effluent at three wastewater treatment plants in South Wales, UK. Following deployment, sampler extracts were analysed using liquid chromatography time-of-flight mass spectrometry. Compounds were identified using an in-house database of pharmaceuticals using a metabolomics workflow. Sixty-eight compounds were identified in all samplers. For the POCIS, substantial losses of sorbent (11-51%) were found during deployment and subsequent laboratory analysis, necessitating the use of a recovery factor. Percentage relative standard deviations varied (with 10 compounds exceeding 30% in both samplers) between individual compounds and between samplers deployed at the three sites. The relative performance of the two devices was evaluated using the mass of analyte sequestered, measured as an integrated peak area. The ratio of the uptake of the pharmaceuticals for the POCIS versus Chemcatcher® was lower (1.84x) than would be expected on the basis of the ratio of active sampling areas (3.01x) of the two devices. The lower than predicted uptake may be attributable to the loose sorbent material moving inside the POCIS when deployed in the field in the vertical plane. In order to overcome this, it is recommended to deploy the POCIS horizontally inside the deployment cage.
Collapse
Affiliation(s)
- Anthony Gravell
- Natural Resources Wales, Faraday Building, Swansea University, Singleton Campus, Swansea, SA2 8PP, UK
| | - Gary R Fones
- School of Earth and Environmental Sciences, University of Portsmouth, Burnaby Road, Portsmouth, PO1 3QL, UK.
| | - Richard Greenwood
- School of Biological Sciences, University of Portsmouth, King Henry Building, King Henry I Street, Portsmouth, PO1 2DY, UK
| | - Graham A Mills
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, White Swan Road, Portsmouth, PO1 2DT, UK
| |
Collapse
|
42
|
Anderson JC, Jabari P, Parajas A, Loeb E, Luong KH, Vahedi A, Wong CS. Evaluation of cold-weather wastewater nitrification technology for removal of polar chemicals of emerging concern from rural Manitoba wastewaters. CHEMOSPHERE 2020; 253:126711. [PMID: 32464769 DOI: 10.1016/j.chemosphere.2020.126711] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 04/03/2020] [Accepted: 04/03/2020] [Indexed: 06/11/2023]
Abstract
Aerated lagoons, typically used by small communities, often provide limited removal of wastewater nutrients. Given increasingly stringent wastewater standards, it is imperative that effective, but economical and easy-to-operate, treatment technologies be developed. The Submerged Attached Growth Reactor (SAGR®) is a treatment process developed to perform nitrification near freezing temperatures. Previous tests on full-scale installations have shown that SAGR could consistently remove ammonia to below current Canadian standards and provide additional total suspended solids and biochemical oxygen demand removal. In this study, we evaluated removal of polar chemicals of emerging concern (CECs), including pharmaceuticals, personal care products, and pesticides, at SAGR installations in two Manitoba First Nations communities (MCN and LPFN) under cold winter conditions. Both showed some removal of diclofenac, naproxen, clarithromycin, metoprolol, and trimethoprim, likely by biotransformation. Average naproxen removal was 21% (2.53 × 103 ng L-1) in MCN and 64% (1.58 × 103 ng L-1) in LPFN. Atenolol was well-removed by SAGR, by 80% on average (range of 64%-94%). Clarithromycin, metoprolol, and trimethoprim removal was similar within and between systems, ranging from 54% to 76% (30.8-3.07 × 102 ng L-1 removed). Carbamazepine was detected in nearly all samples, but was not well-removed, consistent with other treatment studies. Overall, results showed that SAGR technology could moderately remove CECs, while providing the designed treatment performance for other parameters. This work will help to improve our understanding of wastewater treatment in small and/or remote communities with limited infrastructure and challenging cold-weather conditions.
Collapse
Affiliation(s)
- J C Anderson
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
| | - P Jabari
- Nexom Inc., Winnipeg, MB, R2J 3R8, Canada
| | - A Parajas
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
| | - E Loeb
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
| | - K H Luong
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada
| | - A Vahedi
- Red River College, Department of Civil Engineering Technology, Winnipeg, MB, R3H 0J9, Canada
| | - C S Wong
- Richardson College for the Environment, The University of Winnipeg, Winnipeg, MB, R3B 2E9, Canada; Southern California Coastal Water Research Project Authority, Costa Mesa, CA, 92626, USA; Jinan University, School of Environment, Guangzhou, 510632, China.
| |
Collapse
|
43
|
Wang R, Jones KC, Zhang H. Monitoring Organic Pollutants in Waters Using the Diffusive Gradients in the Thin Films Technique: Investigations on the Effects of Biofouling and Degradation. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:7961-7969. [PMID: 32450690 DOI: 10.1021/acs.est.0c00224] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The diffusive gradients in thin films (DGT) passive sampling technique has been increasingly used to provide time-weighted average concentrations of the biorelevant fraction of organic contaminants in waters, with high spatial and temporal resolutions at low cost. This study was tested for the effects of biofouling and compound degradation/loss during sample handling/storage on the DGT measurement of a range of emerging organic pollutants. Biofouling was tested using biofilms collected from the influent and effluent of a typical urban wastewater treatment plant. Most (85%) target compounds showed no detectable effect on the DGT measurement when 8- and 15-day biofouled membrane filters were used. Four storage methods were designed to test for within-sampler degradation/loss for up to 2 months. Intact samplers can be simply stored in polyethylene bags at ambient temperature (18-26 °C) with most compounds stable (mass loss <20%) for at least 1 week. Keeping intact samplers at 4 °C or binding gels in solvent gave good recoveries, with most chemicals being stable for up to 2 months, although the best results were obtained when binding gels were kept in solvent at 4 °C. Recommendations are made for sample handling and storage of DGT samplers used for determination of trace organics in monitoring and surveillance campaigns.
Collapse
Affiliation(s)
- Runmei Wang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, U.K
| | - Kevin C Jones
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, U.K
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, U.K
| |
Collapse
|
44
|
Challis JK, Almirall XO, Helm PA, Wong CS. Performance of the organic-diffusive gradients in thin-films passive sampler for measurement of target and suspect wastewater contaminants. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 261:114092. [PMID: 32059137 DOI: 10.1016/j.envpol.2020.114092] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 01/22/2020] [Accepted: 01/27/2020] [Indexed: 06/10/2023]
Abstract
Although passive sampling is widely accepted as an excellent tool for environmental monitoring, their integration with suspect or non-targeted screening by high-resolution mass spectrometry has been limited. This study describes the application of the organic-diffusive gradients in thin-films (o-DGT) passive sampler as a tool for accurate measurement of both targeted and suspect polar organic contaminants (primarily pharmaceuticals) in wastewater. First, performance of o-DGT was assessed alongside the polar organic chemical integrative sampler (POCIS) and active sampling at two wastewater treatment facilities using targeted analyses. Overall, water concentrations measured by o-DGT, POCIS, and 24-hr integrative active samples were in good agreement with each other. There were exceptions, including a systematic difference between o-DGT and POCIS at certain sites that we propose was a result of site-specific conditions and a difference in sampling rates between the two techniques. The second component of this work involved suspect screening of the o-DGT extracts using high-resolution, high mass accuracy quadrupole time-of-flight mass spectrometry (QTOF). Lamotrigine, venlafaxine, and des-methylvenlafaxine were three suspect compounds identified and selected as proof-of-concept case studies to determine the feasibility and accuracy of o-DGT for estimating water concentrations based upon predicted sampling rates using a previously validated o-DGT diffusion model. Semi-quantification of the suspect compounds was conducting using an average surrogate response factor based on the suite of compounds measured by the targeted analyses. This, combined with the modelled sampling rates provided time-weighted average wastewater concentrations of the identified suspects within a factor of 2 of the true value, confirmed by isotope dilution with mass labelled internal surrogates. To the knowledge of the authors, this work is the first to demonstrate the utility of the o-DGT passive sampler as a potential environmental screening tool that can be integrated into the rapidly advancing field of non-targeted high resolution mass spectrometry.
Collapse
Affiliation(s)
- Jonathan K Challis
- Department of Chemistry, University of Manitoba, Winnipeg, Manitoba, R3T 2N2 Canada.
| | - Xavier Ortiz Almirall
- Laboratory Services Branch, Ontario Ministry of the Environment, Conservation and Parks, Toronto, Ontario, M9P 3V6, Canada; School of Environmental Studies, Queen's University, Kingston, Ontario, K7L 3N6, Canada
| | - Paul A Helm
- Environmental Monitoring and Reporting Branch, Ontario Ministry of the Environment, Conservation and Parks, Toronto, Ontario, M9P 3V6 Canada
| | - Charles S Wong
- Department of Chemistry, University of Manitoba, Winnipeg, Manitoba, R3T 2N2 Canada; Department of Chemistry and Department of Environmental Studies and Sciences, Richardson College for the Environment, The University of Winnipeg, Winnipeg, Manitoba, R3B 2E9, Canada; School of Environment, Jinan University, Guangzhou, 510632, China
| |
Collapse
|
45
|
Stroski KM, Luong KH, Challis JK, Chaves-Barquero LG, Hanson ML, Wong CS. Wastewater sources of per- and polyfluorinated alkyl substances (PFAS) and pharmaceuticals in four Canadian Arctic communities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 708:134494. [PMID: 31791794 DOI: 10.1016/j.scitotenv.2019.134494] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 09/13/2019] [Accepted: 09/15/2019] [Indexed: 06/10/2023]
Abstract
Effective removal of organic contaminants in wastewater effluent poses a challenge to small communities worldwide, particularly in the Arctic due to infrastructure challenges and harsh climates. To understand better the efficacy of current treatment options and risks posed by pharmaceuticals and pesticides on receiving waters in the Arctic, four representative human communities in Nunavut, Canada were evaluated. Per- and polyfluorinated alkyl substances (PFASs) were also investigated in one community. These communities have treatment ranging from primary lagoons, engineered wetlands, and natural lakes. Pharmaceuticals and pesticides were measured using the organic diffusive gradients in thin film (o-DGT) passive sampler in summer 2018. Of the 34 compounds studied, seven pharmaceuticals were found at least once: atenolol, carbamazepine, metoprolol, naproxen, sulfapyridine, sulfamethoxazole, and trimethoprim. With the exception of 5210 ng naproxen/L in Iqaluit, most receiving waters showed negligible amounts of contamination. Iqaluit had the poorest overall system performance while Baker Lake had the best. Measured pharmaceutical concentrations do not appear to pose a significant acute hazard to receiving waters at this time, based on known toxicological endpoints. PFAS concentrations were found to be over 100-fold greater in Cambridge Bay wastewater than previously reported Arctic seawater. Results suggest that wastewater may be an important point source of PFASs in Arctic communities. The o-DGT passive samplers performed well in marine Arctic settings. We recommend further testing of wastewater efficiencies in Arctic communities along with evaluations of seasonal variations.
Collapse
Affiliation(s)
- Kevin M Stroski
- Richardson College for the Environment, University of Manitoba, Winnipeg, MB, Canada
| | - Kim Hoang Luong
- Department of Chemistry, The University of Winnipeg, Winnipeg, MB, Canada
| | - Jonathan K Challis
- Richardson College for the Environment, University of Manitoba, Winnipeg, MB, Canada
| | - Luis G Chaves-Barquero
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, Canada; Escuela de Química, Instituto Tecnológico de Costa Rica, Cartago 159-7050, Costa Rica
| | - Mark L Hanson
- Department of Environment and Geography, University of Manitoba, Winnipeg, MB, Canada
| | - Charles S Wong
- Richardson College for the Environment, University of Manitoba, Winnipeg, MB, Canada; Department of Chemistry, The University of Winnipeg, Winnipeg, MB, Canada; Department of Environment and Geography, University of Manitoba, Winnipeg, MB, Canada; Escuela de Química, Instituto Tecnológico de Costa Rica, Cartago 159-7050, Costa Rica; School of Environment, Jinan University, Guangzhou 510632, China.
| |
Collapse
|
46
|
Guibal R, Buzier R, Lissalde S, Guibaud G. Adaptation of diffusive gradients in thin films technique to sample organic pollutants in the environment: An overview of o-DGT passive samplers. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 693:133537. [PMID: 31357036 DOI: 10.1016/j.scitotenv.2019.07.343] [Citation(s) in RCA: 54] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 07/16/2019] [Accepted: 07/21/2019] [Indexed: 06/10/2023]
Abstract
The adaptation of the diffusive gradients in thin films technique (DGT) to sample organic pollutants in the environment, called o-DGT has been performed since 2011 for various types of organic compounds (e.g. pesticides, pharmaceuticals, hormones, endocrine disrupting chemicals, household and personal care products). To sample these different compounds, configuration of the samplers (mainly receiving phase and diffusive gel) has to be adapted. Up-to-date, sampling of 142 organic compounds by this passive sampler have been tested. This review provides the state-of-art of o-DGT passive sampler development, describing theory and modelling, calibration, configuration of the devices, and field applications. The most used configurations were agarose-XAD-18 and agarose-HLB configuration. o-DGT can be used to sample soils and most of natural waters (range of pH 4-9 and ionic strength 0.001-0.1 M). This review discusses current limitation of o-DGT in light of the feedback of DGT use to sample inorganic contaminants. It mainly concern the low sampling rates currently obtained by o-DGT compared to other passive samplers. This weakness could be compensated in the future with new sampler's design allowing an increase in exposure area.
Collapse
Affiliation(s)
- Robin Guibal
- University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France.
| | - Rémy Buzier
- University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| | - Sophie Lissalde
- University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| | - Gilles Guibaud
- University of Limoges, Peirene EA7500 - URA IRSTEA - Equipe Développement d'indicateurs ou prévision de la qualité des eaux, 123 Avenue Albert Thomas, 87060 Limoges Cedex, France
| |
Collapse
|
47
|
Feng Z, Wang Y, Yang L, Sun T. Coupling mesoporous imprinted polymer based DGT passive samplers and HPLC: A new tool for in-situ selective measurement of low concentration tetrabromobisphenol A in freshwaters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 685:442-450. [PMID: 31176229 DOI: 10.1016/j.scitotenv.2019.05.297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/18/2019] [Accepted: 05/20/2019] [Indexed: 06/09/2023]
Abstract
Accurate measurement of tetrabromobisphenol A (TBBPA) is very important because of its widespread environmental pollution. Diffusive gradients in thin films technique (DGT), an in-situ passive sampling method, is regarded as a reliable and robust measurement technique. A new DGT technique based on mesoporous imprinted polymer was combined with high-pressure liquid chromatography (HPLC) method for sampling, preconcentration and monitoring low concentration TBBPA in natural waters. The diffusion coefficient of TBBPA through the diffusive gel was measured by diffusion cell test and simulated using mathematical expression. The effects of different ambient conditions were tested under laboratory conditions and the performance of DGT sampler was validated in natural waters. The diffusion coefficient of TBBPA in the diffusive gel was measured as 2.18 × 10-6 cm2 s-1 and simulated as in the range 1.41-3.48 × 10-6 cm2 s-1 by Amsden model. Comparison of experimental and theoretical data, the validity of the experimental method can be verified by the mathematical model. The binding agent with mesoporous imprinted polymer showed selective affinity to TBBPA and its adsorption rate met the requirement of DGT device. The DGT method detection limit was at the level of ng L-1 for 7 days deployment. DGT sampler was suitable for application in aquatic environment with a range of pH (4.5-7.6), ionic strength (1 × 10-4 - 0.5 mol L-1), and dissolved organic matter (DOM) concentration (0-10 mg C L-1). The coupling method of DGT and HPLC was a promising technique for in situ sampling, preconcentration and monitoring low concentration TBBPA in most typical natural waters.
Collapse
Affiliation(s)
- Zhongmin Feng
- College of sciences, Northeastern University, Shenyang 110819, China; School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China
| | - Yun Wang
- College of sciences, Northeastern University, Shenyang 110819, China
| | - Lan Yang
- College of sciences, Northeastern University, Shenyang 110819, China
| | - Ting Sun
- College of sciences, Northeastern University, Shenyang 110819, China; School of Materials Science and Engineering, Northeastern University, Shenyang 110819, China.
| |
Collapse
|
48
|
Fang Z, Li K, Li Y, Zhang H, Jones KC, Liu X, Liu S, Ma LQ, Luo J. Development and Application of the Diffusive Gradients in Thin-Films Technique for Measuring Psychiatric Pharmaceuticals in Natural Waters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:11223-11231. [PMID: 31496231 DOI: 10.1021/acs.est.9b03166] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Psychiatric pharmaceuticals are widely distributed in the aquatic environment and have attracted recent attention due to their potential for environmental effects. A robust and reliable in situ passive sampling approach, the diffusive gradients in thin-films (DGT) technique, is developed here to measure 14 psychiatric pharmaceuticals. A new binding material, mixed-mode cation exchange resin (Poly-Sery MCX, 40 μm, CNW, Germany), was used for the first time in DGT and compared to XAD and HLB. Reliable elution efficiencies of the pharmaceuticals from the binding gels were obtained in methanol/ammonia, and diffusion coefficients for all the compounds were determined. The influence of diffusive layer thickness (0.515-2.015 mm), deployment time (3-168 h), and important environmental conditions-pH (3.02-9.45), ionic strength (0.0001-0.5 M), and dissolved organic matter (0-20 mg L-1)-were evaluated. The capacity of XAD, HLB, and MCX gels for binding all the test pharmaceuticals was ∼335 μg per disc, meaning that DGT could theoretically be deployed for over 30 months if there are no competitive effects or confounding factors. The uptake kinetics of psychiatric pharmaceuticals onto MCX gel were much faster than those onto XAD and HLB gels in the first hour. DGT measured concentrations of test pharmaceuticals at two sample points in a river (over 6 days) were comparable to those obtained by grab sampling. This study demonstrates the accuracy and reliability of DGT for measuring psychiatric pharmaceuticals across a wide range of freshwater conditions found in the natural environment.
Collapse
Affiliation(s)
- Zhou Fang
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
| | - Kexin Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
| | - Yuan Li
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
| | - Hao Zhang
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Kevin C Jones
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , United Kingdom
| | - Xinyu Liu
- Monitoring Centre of Pearl River Valley Aquatic Environment , Scientific Institute of Pearl River Water Resources Protection , Guangzhou 510611 , China
| | - Shengyu Liu
- Monitoring Centre of Pearl River Valley Aquatic Environment , Scientific Institute of Pearl River Water Resources Protection , Guangzhou 510611 , China
| | - Lena Q Ma
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
- Soil and Water Science Department , University of Florida , Gainesville , Florida 32611 , United States
| | - Jun Luo
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment , Nanjing University , Nanjing , Jiangsu 210023 , P. R. China
| |
Collapse
|
49
|
Wang R, Zou Y, Luo J, Jones KC, Zhang H. Investigating Potential Limitations of Current Diffusive Gradients in Thin Films (DGT) Samplers for Measuring Organic Chemicals. Anal Chem 2019; 91:12835-12843. [DOI: 10.1021/acs.analchem.9b02571] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Affiliation(s)
- Runmei Wang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Yitao Zou
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, People’s Republic of China
| | - Jun Luo
- State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing, Jiangsu 210023, People’s Republic of China
| | - Kevin C. Jones
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| | - Hao Zhang
- Lancaster Environment Centre, Lancaster University, Lancaster LA1 4YQ, United Kingdom
| |
Collapse
|
50
|
Li Y, Chen CEL, Chen W, Chen J, Cai X, Jones KC, Zhang H. Development of a Passive Sampling Technique for Measuring Pesticides in Waters and Soils. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2019; 67:6397-6406. [PMID: 31067050 DOI: 10.1021/acs.jafc.9b00040] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
It is essential to monitor pesticides in the environment to help ensure water and soil quality. The diffusive gradients in thin-films (DGT) technique can measure quantitative in situ labile (available) concentrations of chemicals in water, soil, and sediments. This study describes the systematic development of the DGT technique for nine current pesticides, selected to be representative of different classes with a wide range of properties, with two types of resins (HLB (hydrophilic-lipophilic-balanced) and XAD 18) as binding layer materials. The masses of pesticides accumulated by DGT devices were proportional to the deployment time and in inverse proportion to the thickness of the diffusive layer, in line with DGT theoretical predictions. DGT with both resin gels were tested in the laboratory for the effects of typical environmental factors on the DGT measurements. DGT performance was independent of the following: pH in the range of 4.7-8.2; dissolved organic matter concentrations <20 mg L-1; and ionic strength from 0.01 to 0.25 M, although it was slightly affected at 0.5 M in some cases. This confirms DGT as a sampler suitable for controlled studies of environmental processes affecting pesticides. Field applications of DGT to measure pesticides in situ in waters and controlled laboratory measurements on five different soils (prepared at fixed soil/water ratios) demonstrated DGT is a suitable tool for environmental monitoring in waters and for investigating chemical processes in soils.
Collapse
Affiliation(s)
- Yanying Li
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , U.K
| | - Chang-Er L Chen
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , U.K
| | - Wei Chen
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , U.K
| | - Jingwen Chen
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology , Dalian University of Technology , Linggong Road 2 , Dalian 116024 , China
| | - Xiyun Cai
- Key Laboratory of Industrial Ecology and Environmental Engineering (MOE), School of Environmental Science and Technology , Dalian University of Technology , Linggong Road 2 , Dalian 116024 , China
| | - Kevin C Jones
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , U.K
| | - Hao Zhang
- Lancaster Environment Centre , Lancaster University , Lancaster LA1 4YQ , U.K
| |
Collapse
|