1
|
Wang CP, Chang YC, Lin YH, Jia Q. Effect of coil diameter on water disinfection efficiency in a helical photoreactor using ultraviolet-C light emitting diodes. ENVIRONMENTAL TECHNOLOGY 2024:1-10. [PMID: 38753520 DOI: 10.1080/09593330.2024.2354122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Accepted: 04/28/2024] [Indexed: 05/18/2024]
Abstract
This study investigated the disinfection efficiency of a photoreactor equipped with a helical water flow channel and ultraviolet-C (UV-C) light emitting diodes (LEDs). Theoretical simulations and biodosimetry tests were conducted to investigate the effects of coil diameter and flow rate on the reactor's performance in inactivating Escherichia coli. The interplay between hydrodynamics and UV radiation was analyzed to determine the UV fluence absorbed by the microbes. The simulations revealed that, primarily due to the specific radiation pattern of the UV LEDs, the coil diameter strongly influenced the distribution of irradiance in the water and the UV fluence received by microbes. The experimental results indicated that the photoreactor achieved the highest inactivation value of 2.8 log when the coil diameter was 48 mm for a flow rate of 40 mL/min; this log value was superior to those for coil diameters of 16, 32, 64, and 80 mm by approximately 1.9, 0.4, 0.5, and 0.7 log units, respectively. This optimal coil diameter leading to the maximal UV irradiance and the highest degree of irradiance uniformity along the flow channel. This study offers design guidelines for constructing a high-efficiency water disinfection reactor with a helical flow channel configuration.
Collapse
Affiliation(s)
- Chien-Ping Wang
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan, ROC
| | - Yu-Cheng Chang
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan, ROC
| | - Yung-Hsiang Lin
- Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan, ROC
| | - Qiang Jia
- Faculty of Materials and Manufacturing, Beijing University of Technology, Beijing, People's Republic of China
| |
Collapse
|
2
|
Fang C, Yang W, Lu N, Xiao R, Du Z, Wang Q, Chu W. Alkaline chlorination of drinking water: A trade-off between genotoxicity control and trihalomethane formation. WATER RESEARCH 2023; 246:120692. [PMID: 37890262 DOI: 10.1016/j.watres.2023.120692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Revised: 09/18/2023] [Accepted: 10/02/2023] [Indexed: 10/29/2023]
Abstract
The pH of chlorination is an important factor affecting the formation of disinfection byproducts (DBPs). In this study, we discovered that the genotoxicity induced by chlorination can be effectively reduced under alkaline conditions. As the pH of chlorination increased from 6.5 to 8.5, the genotoxicity of investigated waters reduced by ∼30-90 %. By assessing the genotoxicity of the mixture of measured DBPs, it was found that the contribution of measured DBPs to the overall genotoxicity was lower than 5 %, and the significant reduction of genotoxicity was largely associated with unknown DBPs. The result of Pearson's correlation analysis indicated that humified organics and soluble microbial byproducts were likely responsible for the genotoxicity, and their derived genotoxic compounds (i.e., unknown DBPs) tended to decompose during alkaline chlorination. However, the control of genotoxicity by alkaline chlorination was achieved at the expense of promoting trihalomethane (THM) formation. The highest genotoxicity reduction (93 %) was observed for chlorinated granular activated carbon-treated waters, but the formation of THMs was promoted to a level approaching that in untreated waters. The inconsistent trend of overall genotoxicity and THM concentration during alkaline chlorination suggested the inadequacy of THMs as metric for DBP exposure, and considerations should also be given to the toxicity of bulk water in addition to regulated DBPs.
Collapse
Affiliation(s)
- Chao Fang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai 200092, China
| | - Wenyuan Yang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai 200092, China
| | - Nannan Lu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shandong Province Water Supply and Drainage Monitoring Centre, Jinan 250101, China
| | - Rong Xiao
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai 200092, China
| | - Zhenqi Du
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai 200092, China
| | - Qi Wang
- College of Life and Environmental Science, Wenzhou University, Wenzhou 325035, China
| | - Wenhai Chu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Ministry of Education Key Laboratory of Yangtze River Water Environment, Tongji University, Shanghai 200092, China.
| |
Collapse
|
3
|
Lu Z, Ling Y, Sun W, Liu C, Mao T, Ao X, Huang T. Antibiotics degradation by UV/chlor(am)ine advanced oxidation processes: A comprehensive review. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 308:119673. [PMID: 35760199 DOI: 10.1016/j.envpol.2022.119673] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 05/21/2022] [Accepted: 06/20/2022] [Indexed: 06/15/2023]
Abstract
Antibiotics are emerging contaminants in aquatic environments which pose serious risks to the ecological environment and human health. Advanced oxidation processes (AOPs) based on ultraviolet (UV) light have good application prospects for antibiotic degradation. As new and developing UV-AOPs, UV/chlorine and derived UV/chloramine processes have attracted increasing attention due to the production of highly reactive radicals (e.g., hydroxyl radical, reactive chlorine species, and reactive nitrogen species) and also because they can provide long-lasting disinfection. In this review, the main reaction pathways of radicals formed during the UV/chlor (am)ine process are proposed. The degradation efficiency, influencing factors, generation of disinfection by-products (DBPs), and changes in toxicity that occur during antibiotic degradation by UV/chlor (am)ine are reviewed. Based on the statistics and analysis of published results, the effects caused by energy consumption, defined as electrical energy per order (EE/O), increase in the following order: UV/chlorine < UV/peroxydisulfate (PDS)< UV/H2O2 < UV/persulfate (PS) < 265 nm and 285 nm UV-LED/chlorine (EE/O). Some inherent problems that affect the UV/chlor (am)ine processes and prospects for future research are proposed. The use of UV/chlor (am)ine AOPs is a rich field of research and has promising future applications, and this review provides a theoretical basis for that.
Collapse
Affiliation(s)
- Zedong Lu
- School of Environment, Tsinghua University, Beijing, 100084, China
| | - Yanchen Ling
- School of Environment, Tsinghua University, Beijing, 100084, China; Suzhou University of Science and Technology, Suzhou, 215009, China
| | - Wenjun Sun
- School of Environment, Tsinghua University, Beijing, 100084, China; Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou, 215163, China.
| | - Chaoran Liu
- Beijing Waterworks Group Co., LTD, Beijing, 100031, China
| | - Ted Mao
- Research Institute for Environmental Innovation (Suzhou) Tsinghua, Suzhou, 215163, China; MW Technologies, Inc., London, Ontario, Canada
| | - Xiuwei Ao
- School of Environment, Tsinghua University, Beijing, 100084, China
| | - Tianyin Huang
- Suzhou University of Science and Technology, Suzhou, 215009, China
| |
Collapse
|
4
|
Bai W, Takao Y, Kubo T. First evaluation of genotoxicity of strong bases and zwitterions in treated household effluents. JOURNAL OF HAZARDOUS MATERIALS 2021; 416:126053. [PMID: 34492893 DOI: 10.1016/j.jhazmat.2021.126053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 04/28/2021] [Accepted: 05/03/2021] [Indexed: 06/13/2023]
Abstract
Various genotoxic substances in household effluents have not been sufficiently studied. The purpose of this study is to evaluate them using the umu test after dividing them based on the acid-base properties of their functional groups by solid-phase extraction cartridges. The results of the samples concentrated with reverse-phase cartridges showed that the substances with acid functional groups had stronger genotoxicity as 4.1-12.1 ng-4-NQO/mL without S9 enzyme and 17.4-51.8 ng-2-AA/mL with S9 enzyme, while the basic substances also showed a certain degree of toxicity. The results of dividing the effluents by acid-base properties using ion-exchange cartridges showed that chemical substances with strong acid functional groups did not demonstrate genotoxicity. It was found that the genotoxicity of chemicals with functional groups of weak acids was half of that of the total amount. The genotoxicity of the neutral substance was not strong, and the genotoxicity of the weak basic substances was negligible. The zwitterions and substances with strong basic functional groups showed about half the total genotoxicity. This is the first report that has investigated the genotoxicity of zwitterions in effluents.
Collapse
Affiliation(s)
- Wenzhi Bai
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan.
| | - Yuji Takao
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| | - Takashi Kubo
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki 852-8521, Japan
| |
Collapse
|
5
|
Hua Z, Li D, Wu Z, Wang D, Cui Y, Huang X, Fang J, An T. DBP formation and toxicity alteration during UV/chlorine treatment of wastewater and the effects of ammonia and bromide. WATER RESEARCH 2021; 188:116549. [PMID: 33152588 DOI: 10.1016/j.watres.2020.116549] [Citation(s) in RCA: 51] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/16/2020] [Accepted: 10/21/2020] [Indexed: 05/03/2023]
Abstract
The UV/chlorine process is efficient for the abatement of micropollutants; yet, the formation of disinfection by-products (DBPs) and the toxicity can be altered during the treatment. This study investigated effluent organic matter characterization, DBP formation and toxicity alteration after the UV/chlorine treatment of wastewater; particularly, typical water matrix components in wastewater, namely, ammonia and bromide, were studied. The raw wastewater contained low levels of ammonia (3 µM) and bromide (0.5 µM). The UV/chlorine treatment efficiently eliminated 90 - 94% of fluorescent components. Compared with chlorination alone, a 20 min UV/chlorine treatment increased the formation of trihalomethanes (THMs), haloacetic acids (HAAs), chloral hydrate (CH), haloacetonitriles (HANs), trichloronitromethane (TCNM) and haloacetamides (HAcAms) by 90 - 508%. In post-chlorination after the UV/chlorine treatment, the formation of CH, HANs, TCNM and HAcAms increased by 77 - 274%, whereas the formation of both THMs and HAAs increased slightly by 11%. Meanwhile, the calculated cytotoxicity and genotoxicity of DBPs increased considerably after the UV/chlorine treatment and in post-chlorination, primarily due to the increased formation of HAAs and nitrogenous DBPs (N-DBPs). However, the acute toxicity of the wastewater to Vibrio fischeri and genotoxicity determined by the umu test decreased by 19% and 76%, respectively, after the 20 min UV/chlorine treatment. An additional 200 µM ammonia decreased the formation of all detected DBPs during the UV/chlorine treatment and 24 h post-chlorination, except that TCNM formation increased by 11% during post-chlorination. The acute toxicity of wastewater spiked with 200 µM ammonia was 32% lower than that of raw wastewater after the UV/chlorine treatment, but the genotoxicity was 58% higher. The addition of 1 mg/L bromide to the UV/chlorine process dramatically increased the formation of brominated DBPs and the overall calculated cytotoxicity and genotoxicity of DBPs. However, the acute toxicity and genotoxicity of the wastewater decreased by 7% and 100%, respectively, when bromide was added to the UV/chlorine treatment. This study illuminated that UV/chlorine treatment can decrease acute and geno- toxicities of wastewater efficiently.
Collapse
Affiliation(s)
- Zhechao Hua
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China
| | - Dan Li
- Department of Environmental Science & Engineering, Fudan University, Shanghai 200433, China
| | - Zihao Wu
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China
| | - Ding Wang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China; Independent researcher, 25 Tuscany Springs Terr NW, Calgary, AB T3L 2V2, Canada
| | - Yonglin Cui
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China
| | - Xiongfei Huang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China
| | - Jingyun Fang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou 510275, China.
| | - Taicheng An
- Guangdong Key Laboratory of Environmental Catalysis and Health Risk Control, School of Environmental Science and Engineering, Institute of Environmental Health and Pollution Control, Guangdong University of Technology, Guangzhou 510006, China
| |
Collapse
|
6
|
Manivannan B, Massalha N, Halahlih F, Eltzov E, Nguyen TH, Sabbah I, Borisover M. Water toxicity evaluations: Comparing genetically modified bioluminescent bacteria and CHO cells as biomonitoring tools. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2020; 203:110984. [PMID: 32888605 DOI: 10.1016/j.ecoenv.2020.110984] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Revised: 06/30/2020] [Accepted: 06/30/2020] [Indexed: 06/11/2023]
Abstract
The use of water for drinking and agriculture requires knowledge of its toxicity. In this study, we compared the use of genetically modified bioluminescent (GMB) bacteria whose luminescence increases in the presence of toxicants and Chinese Hamster Ovary (CHO) cells for the characterization of the toxicity of water samples collected from a lake and streams, hydroponic and aquaponic farms, and a wastewater treatment plant. GMB bacteria were used to probe genotoxicity, cytotoxicity and reactive oxygen species-induced effects in the whole water samples. Unlike GMB bacteria, the use of CHO cells requires XAD resin-based pre-concentration of toxic material present in water samples for the subsequent cytotoxicity assay. In addition to the examination of the toxicity of the water from the different sources, the GMB bacteria were also used to test the XAD extracts diluted to the concentrations causing 50% growth inhibition of the CHO cells. The two biomonitoring tools provided different results when they were used to test the above-mentioned diluted XAD extracts. A pre-concentration procedure based on adsorption by XAD resins with subsequent elution was not sufficient to represent the material responsible for the toxicity of the whole water samples toward the GMB bacteria. Therefore, the use of XAD resin extracts may lead to major underestimates of the toxicity of water samples. Although the toxicity findings obtained using the GMB bacteria and CHO cells may not correlate with each another, the GMB bacteria assay did provide a mechanism-specific biomonitoring tool to probe the toxicity of water samples without a need for the pre-concentration step.
Collapse
Affiliation(s)
- Bhuvaneshwari Manivannan
- Institute of Soil, Water and Environmental Sciences, Agricultural Research Organization, The Volcani Center, Israel.
| | - Nedal Massalha
- The Institute of Applied Research, The Galilee Society, P.O. Box 437, Shefa-Amr, Israel; Department of Natural Resources & Environmental Management, Faculty of Management, University of Haifa, 199 Aba Khoushy Ave., Mount Carmel, Haifa, 3498838, Israel.
| | - Fares Halahlih
- The Institute of Applied Research, The Galilee Society, P.O. Box 437, Shefa-Amr, Israel.
| | - Evgeni Eltzov
- Institute of Postharvest and Food Science, Department of Postharvest Science, Agricultural Research Organization, The Volcani Center, Israel.
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, Safe Global Water Institute, University of Illinois at Urbana-Champaign, USA.
| | - Isam Sabbah
- The Institute of Applied Research, The Galilee Society, P.O. Box 437, Shefa-Amr, Israel; Prof. Ephraim Katzir Department of Biotechnology Engineering, Braude College, Karmiel, Israel.
| | - Mikhail Borisover
- Institute of Soil, Water and Environmental Sciences, Agricultural Research Organization, The Volcani Center, Israel.
| |
Collapse
|
7
|
Cui Q, Liu H, Yang HW, Lu Y, Chen Z, Hu HY. Bacterial removal performance and community changes during advanced treatment process: A case study at a full-scale water reclamation plant. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 705:135811. [PMID: 31837874 DOI: 10.1016/j.scitotenv.2019.135811] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 11/25/2019] [Accepted: 11/26/2019] [Indexed: 06/10/2023]
Abstract
Advanced treatment is of great significance to water reclamation and reuse, which can improve water quality, control microbial risks and guarantee the safety of water reuse. This study evaluates the microbial quantity and bacterial community dynamics during advanced wastewater treatment and reuse processes (i.e. denitrification biofilter (DNBF), ultrafiltration (UF), ozonation, ultraviolet (UV) disinfection) at a large-scale water reclamation plant. It is found that different treatment processes had significant influence on the cultivability of total bacteria and the log reduction values of fecal coliform at DNBF, UF, ozonation and UV are calculated as 0.38, 2.46, 0.38 and 1.63 respectively. Moreover, the bacterial diversity in the treatment process showed apparent spatial differences, among which the effluent from ozonation process had the lowest bacterial diversity. Sequencing analysis indicated the existence of pathogenic bacterium such as Arcobacter, Bacteroides and Pseudomonas in the secondary effluent. Notably, Pseudomonas remained the most dominant species (relative abundance 41.9% in UV effluent) in reclaimed water after advanced treatment processes, which calls for high attention to sustainable water reuse. In order to inhibit bacterial regrowth in the storage tank, chlorine disinfection is recommended to improve the continuous disinfection capability of the system.
Collapse
Affiliation(s)
- Qi Cui
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Hai Liu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Hong-Wei Yang
- Research Institute for Environmental Innovation (Suzhou), Tsinghua University, Suzhou 215163, PR China
| | - Yun Lu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|
8
|
Bai W, Takao Y, Kubo T. Evaluation of genotoxicity potential of household effluents from onsite wastewater treatment systems using umu test. JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH. PART A 2020; 83:36-44. [PMID: 31989873 DOI: 10.1080/15287394.2020.1719447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Household effluents are predominantly treated by wastewater treatment plants (WWTPs). Other treatment methods, which were examined in this study, are also used in the countryside. These treatment modes include (1) onsite toilet wastewater treatment system (OTWTS), (2) onsite wastewater treatment system (OWTS), (3) community wastewater treatment system (CWTS), and (4) onsite vault toilet (OVT). Household effluents consist of excrements and urine released from toilets as well as wastewater released from kitchens and bathrooms. In the present study, household effluents that were discharged from the residential areas having undergone similar treatment methodologies were compared using the umu test, an in vitro bioassay to assess genotoxicity potential. The different treatment methodologies were categorized based upon whether the two kinds of wastewater were mixed or not mixed and treated or not treated. Treated wastewater containing excrements and urine from the OTWTS exhibited the strongest genotoxicity potential compared to other effluents, whereas most of the kitchen and bathroom wastewater from OVT did not display genotoxicity. Data indicated that the genotoxicants in the effluents originated primarily from excrements and urine, and may increase an adverse environmental risk.
Collapse
Affiliation(s)
- Wenzhi Bai
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, Nagasaki, Japan
| | - Yuji Takao
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, Nagasaki, Japan
| | - Takashi Kubo
- Graduate School of Fisheries and Environmental Sciences, Nagasaki University, Nagasaki, Japan
| |
Collapse
|
9
|
Bhuvaneshwari M, Eltzov E, Veltman B, Shapiro O, Sadhasivam G, Borisover M. Toxicity of chlorinated and ozonated wastewater effluents probed by genetically modified bioluminescent bacteria and cyanobacteria Spirulina sp. WATER RESEARCH 2019; 164:114910. [PMID: 31382150 DOI: 10.1016/j.watres.2019.114910] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 07/18/2019] [Accepted: 07/22/2019] [Indexed: 06/10/2023]
Abstract
Chlorination and ozonation of various waters may be associated with the formation of toxic disinfection byproducts (DBPs) and cause health risks to humans. Monitoring the toxicity of chlorinated and ozonated water and identification of different toxicity mechanisms are therefore required. This study is one of its kind to examine the toxic effects of chlorinated and ozonated wastewater effluents on three genetically modified bioluminescent bacteria, in comparison to the naturally isolated cyanobacteria, Spirulina strains as test systems. Three different secondary wastewater effluents were collected from treatment plants, chlorinated using sodium hypochlorite (at 1 and 10 mg L-1 of chlorine) or treated using 3-4 mg L-1 of ozone at different contact times. As compared to cyanobacterial Spirulina sp., the genetically modified bacteria enhancing bioluminescence at the presence of stress agents demonstrated greater sensitivity to the toxicity induction and have also provided mechanism-specific responses associated with genotoxicity, cytotoxicity and reactive oxygen species (ROS) generation in wastewater effluents. Effects of effluent chlorination time and chlorine concentration revealed by means of bioluminescent bacteria suggest the formation of genotoxic and cytotoxic DBPs followed with their possible disappearance at longer times. Ozonation could degrade genotoxic compounds in some effluents, but the cytotoxic potential of wastewater effluents may certainly increase with ozonation time. No induction of ROS-related toxicity was detected in either chlorinated or ozonated wastewater effluents. UV absorbance- and fluorescence emission-based spectroscopic characteristics may be variously correlated with changes in genotoxicity in ozonated effluents, however, no associations were obtained in chlorinated wastewater effluents. The bacterial response to the developed mechanism-specific toxicity differs among wastewater effluents, reflecting variability in effluent compositions.
Collapse
Affiliation(s)
- M Bhuvaneshwari
- Institute of Soil, Water and Environmental Sciences, Agricultural Research Organization, The Volcani Center, Israel.
| | - Evgeni Eltzov
- Institute of Postharvest and Food Science, Department of Postharvest Science, Agricultural Research Organization, The Volcani Center, Israel.
| | - Boris Veltman
- Institute of Postharvest and Food Science, Department of Postharvest Science, Agricultural Research Organization, The Volcani Center, Israel.
| | - Orr Shapiro
- Institute of Postharvest and Food Science, Department of Food Quality and Safety, Agricultural Research Organization, The Volcani Center, Israel.
| | - Giji Sadhasivam
- Institute of Postharvest and Food Science, Department of Food Quality and Safety, Agricultural Research Organization, The Volcani Center, Israel.
| | - Mikhail Borisover
- Institute of Soil, Water and Environmental Sciences, Agricultural Research Organization, The Volcani Center, Israel.
| |
Collapse
|
10
|
Sun J, Chen Y, Xiang Y, Ling L, Fang J, Shang C. Oxidative debromination of 2,2-bis(bromomethyl)-1,3-propanediol by UV/persulfate process and corresponding formation of brominated by-products. CHEMOSPHERE 2019; 228:735-743. [PMID: 31071560 DOI: 10.1016/j.chemosphere.2019.04.168] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 04/12/2019] [Accepted: 04/22/2019] [Indexed: 06/09/2023]
Abstract
This study investigated the oxidative debromination of 2,2-bis(bromomethyl)-1,3-propanediol (BBMP), a widely used brominated flame retardant, and the corresponding formation of brominated by-products by the UV/persulfate process. The debromination of BBMP by the UV/persulfate process was primarily driven by sulfate radicals (SO4-) at pHs 4.0-6.0 and hydroxyl radicals (HO) at pHs 9.0-12.0. The debromination rate increased with increasing pH from 4.0 to 9.0 and remained the same at pHs 9.0 and 12.0. Bromate was formed through the oxidation of bromide released from BBMP mainly by SO4-, with free bromine as a key intermediate. Bromate formation increased with increasing pH from 4.0 to 6.0, while it remarkably decreased with increasing pH from 6.0 to 12.0. This was mainly due to the transformation of SO4- to HO and also the quenching of bromine atoms that were the key intermediate for the formation of free bromine, by hydroxyl ions at the alkaline pH. In addition, the oxidative debromination of BBMP resulted in a significant decrease in the concentrations of total organic bromine, but the formation of brominated acetic acids and unknown brominated organic by-products. The concentrations of brominated organic by-products firstly increased and then decreased with prolonged reaction time. Also, the formation of brominated organic by-products and genotoxicity at pH 9.0 were much lower than that at pH 6.0. In this study, we propose that the UV/persulfate process under mildly alkaline conditions not only debrominates BBMP efficiently but also eliminates the formation of bromate and brominated organic by-products and genotoxicity.
Collapse
Affiliation(s)
- Jianliang Sun
- School of Chemistry & Environment, South China Normal University, Guangzhou, China; Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Yu Chen
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Yingying Xiang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Li Ling
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
| | - Jingyun Fang
- Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, School of Environmental Science and Engineering, Sun Yat-Sen University, Guangzhou, China.
| | - Chii Shang
- Department of Civil and Environmental Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong; Hong Kong Branch of Chinese National Engineering Research Center for Control & Treatment of Heavy Metal Pollution, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong.
| |
Collapse
|
11
|
Li M, Chen Z, Wang Z, Wen Q. Investigation on degradation behavior of dissolved effluent organic matter, organic micro-pollutants and bio-toxicity reduction from secondary effluent treated by ozonation. CHEMOSPHERE 2019; 217:223-231. [PMID: 30415120 DOI: 10.1016/j.chemosphere.2018.11.039] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 11/01/2018] [Accepted: 11/04/2018] [Indexed: 06/09/2023]
Abstract
The environmental risk of secondary effluent has caused increasing attention in recent years, the negative effect of dissolved effluent organic matters (dEfOM) and organic micro-pollutants (OMPs) was a hot research point. In this research, the degradation behavior of dEfOM and fourteen OMPs in the ozonation was revealed using spectroscopic and chromatographic tools. Ozonation was effective for reducing UV254, but had limited effect in dissolved organic carbon reduction. The dEfOM with shorter absorption wavelength was preferentially removed in the ozonation (230 nm > 240 nm > 254 nm) and high molecular weight humics was largely reduced by the ozonation. Soluble microbial by-products were more reactive with ozone than humic acid as reflected by the fluorescence. Degradation behavior of the OMPs was identified based on their elimination kinetics and molecular structures and a simplified classification method was proposed. The group I OMPs (logkO3>5) showed high removal efficiency with 1 mg/L of ozone, while the removal of group II OMPs (1< logkO3<5) was largely dependent on the ozone dose. The CC bond, deprotonated amidogen, phenolic, aniline and anisole groups in these OMPs structures were the main reaction sites with ozone. The group III OMPs without active groups in the molecules showed slight removal in the ozonation. Moreover, genotoxicity and estrogenic activity were simultaneously analyzed for further evaluation on the risk of the effluent. The genotoxicity and estrogenic activity of the secondary effluent were 73.46 μg 4-NQO/L and 519.86 ng E2/L, respectively and an ozone dose of 10 mg/L could reduce the bio-toxicity to the detection limit.
Collapse
Affiliation(s)
- Mo Li
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology (SKLUWRE, HIT), Harbin 150090, PR China
| | - Zhiqiang Chen
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology (SKLUWRE, HIT), Harbin 150090, PR China; School of Civil Engineering, Lanzhou University of Technology, Lanzhou 730070, PR China
| | - Zhenzhe Wang
- Jiangsu Huaxin Urban Planning & Design Institute Co Ltd, Lianyungang 200000, PR China
| | - Qinxue Wen
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology (SKLUWRE, HIT), Harbin 150090, PR China.
| |
Collapse
|
12
|
Zhu X, Li M, Ma D, Chen L. Changes of biotoxicity in food waste fermentation wastewater treated by a membrane bioreactor system. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:18728-18736. [PMID: 29707749 DOI: 10.1007/s11356-018-1857-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2017] [Accepted: 03/21/2018] [Indexed: 06/08/2023]
Abstract
The biotoxicity of industrial effluents has attracted much concern in the wastewater treatment process. This research performed the biological treatment of the wastewater generated from food waste fermentation by anaerobic/anaerobic/anoxic/aerobic-membrane bioreactor (A3-MBR) system aiming at the meet of discharge standards and elimination of ecological risks to aquatic environment. The results showed that the A3-MBR could effectively remove pollutants such as COD, TN, ammonia, and TP in the wastewater. The study of biotoxicity revealed that the acute toxicity was mainly contained in the polar and mid-polar fractions of the wastewater, and the remained acute toxicity was less than 0.6 TU, much lower than the secondary effluent of domestic wastewater treatment plant. The genotoxicity was found abundantly in the polar fractions and less in mid-polar fractions, and a relatively low genotoxicity (0.086 μg 4-NQO/L) was obtained in the final effluent of the treatment system. The fulvic acid-like compounds and humic acid-like compounds were the main cause of the acute toxicity, while the aromatic proteins and soluble microbial by-products mainly resulted in the genotoxicity in the wastewater.
Collapse
Affiliation(s)
- Xiaobiao Zhu
- College of Chemical Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Mengqi Li
- School of Environment, Tsinghua University, Beijing, 100084, China
- Beijing General Municipal Engineering Design and Research Institute Co., Ltd, Beijing, 100082, China
| | - Dehua Ma
- School of Environment, Tsinghua University, Beijing, 100084, China
| | - Lujun Chen
- School of Environment, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
13
|
Advanced Approaches to Model Xenobiotic Metabolism in Bacterial Genotoxicology In Vitro. ADVANCES IN BIOCHEMICAL ENGINEERING/BIOTECHNOLOGY 2017. [PMID: 27619490 DOI: 10.1007/10_2016_4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register]
Abstract
During the past 30 years there has been considerable progress in the development of bacterial test systems for use in genotoxicity testing by the stable introduction of expression vectors (cDNAs) coding for xenobiotic-metabolizing enzymes into bacterial cells. The development not only provides insights into the mechanisms of bioactivation of xenobiotic compounds but also evaluates the roles of enzymes involved in metabolic activation or inactivation in chemical carcinogenesis. This review describes recent advances in bacterial genotoxicity assays and their future prospects, with a focus on the development and application of genetically engineering bacterial cells to incorporate some of the enzymatic activities involved in the bio-activation process of xenobiotics. Various genes have been introduced into bacterial umu tester strains encoding enzymes for genotoxic bioactivation, including bacterial nitroreductase and O-acetyltransferase, human cytochrome P450 monooxygenases, rat glutathione S-transferases, and human N-acetyltransferases and sulfotransferases. Their application has provided new tools for genotoxicity assays and for studying the role of biotransformation in chemical carcinogenesis in humans.
Collapse
|
14
|
Dong S, Masalha N, Plewa MJ, Nguyen TH. Toxicity of Wastewater with Elevated Bromide and Iodide after Chlorination, Chloramination, or Ozonation Disinfection. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:9297-9304. [PMID: 28691804 DOI: 10.1021/acs.est.7b02345] [Citation(s) in RCA: 61] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Water reuse is receiving unprecedented attention as many areas around the globe attempt to better-manage their fresh water resources. Wastewaters in coastal regions may contain elevated levels of bromide (Br-) and iodide (I-) from seawater intrusion or high mineral content in the source waters. Disinfection of such wastewater is essential to prevent the spread of pathogens; however, little is known about the toxicity of the treated wastewater. In this study, we evaluated the genotoxicity to Chinese hamster ovary (CHO) cells induced by municipal secondary wastewater effluent amended with elevated Br- and I- after disinfection by chlorine, chloramines, or ozone. We calibrated and applied an N-acetylcysteine (NAC) thiol reactivity assay as a surrogate for thiol reactivity with biological proteins (glutathione) of wastewater samples. Chlorination of wastewaters produced CHO cell genotoxicity comparable to chloramination, 3.9 times more genotoxic than the nondisinfected controls. Ozonated wastewater was at least 3 times less genotoxic than the samples treated with chlorine-based disinfectants and was not significantly different compared with the nondisinfected controls. Positive and significant correlations were observed among genotoxicity, cytotoxicity, and NAC thiol reactivity for all disinfected samples. These results indicate that the ozonation of wastewater with high Br- and I- levels may yield organics with lower genotoxicity to CHO cells than chlorine-based disinfection. NAC thiol reactivity, although excluding the possible effect of bromate from ozonation in this work, could be used as a rapid in chemico screen for potential genotoxicity and cytotoxicity in mammalian cells exposed to disinfected wastewaters.
Collapse
Affiliation(s)
- Shengkun Dong
- Department of Civil and Environmental Engineering, ‡Department of Crop Sciences, and §Safe Global Water Institute, University of Illinois , Urbana, Illinois 61801, United States
| | - Nedal Masalha
- Department of Civil and Environmental Engineering, ‡Department of Crop Sciences, and §Safe Global Water Institute, University of Illinois , Urbana, Illinois 61801, United States
| | - Michael J Plewa
- Department of Civil and Environmental Engineering, ‡Department of Crop Sciences, and §Safe Global Water Institute, University of Illinois , Urbana, Illinois 61801, United States
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, ‡Department of Crop Sciences, and §Safe Global Water Institute, University of Illinois , Urbana, Illinois 61801, United States
| |
Collapse
|
15
|
Du Y, Lv XT, Wu QY, Zhang DY, Zhou YT, Peng L, Hu HY. Formation and control of disinfection byproducts and toxicity during reclaimed water chlorination: A review. J Environ Sci (China) 2017; 58:51-63. [PMID: 28774626 DOI: 10.1016/j.jes.2017.01.013] [Citation(s) in RCA: 109] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2016] [Revised: 01/26/2017] [Accepted: 01/30/2017] [Indexed: 06/07/2023]
Abstract
Chlorination is essential to the safety of reclaimed water; however, this process leads to concern regarding the formation of disinfection byproducts (DBPs) and toxicity. This study reviewed the formation and control strategies for DBPs and toxicity in reclaimed water during chlorination. Both regulated and emerging DBPs have been frequently detected in reclaimed water during chlorination at a higher level than those in drinking water, indicating they pose a greater risk to humans. Luminescent bacteria and Daphnia magna acute toxicity, anti-estrogenic activity and cytotoxicity generally increased after chlorination because of the formation of DBPs. Genotoxicity by umu-test and estrogenic activity were decreased after chlorination because of destruction of toxic chemicals. During chlorination, water quality significantly impacted changes in toxicity. Ammonium tended to attenuate toxicity changes by reacting with chlorine to form chloramine, while bromide tended to aggravate toxicity changes by forming hypobromous acid. During pretreatment by ozonation and coagulation, disinfection byproduct formation potential (DBPFP) and toxicity formation potential (TFP) occasionally increase, which is accompanied by DOC removal; thus, the decrease of DOC was limited to indicate the decrease of DBPFP and TFP. It is more important to eliminate the key fraction of precursors such as hydrophobic acid and hydrophilic neutrals. During chlorination, toxicities can increase with the increasing chlorine dose and contact time. To control the excessive toxicity formation, a relatively low chlorine dose and short contact time were required. Quenching chlorine residual with reductive reagents also effectively abated the formation of toxic compounds.
Collapse
Affiliation(s)
- Ye Du
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Xiao-Tong Lv
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Qian-Yuan Wu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Da-Yin Zhang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Yu-Ting Zhou
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Lu Peng
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, China.
| |
Collapse
|
16
|
Dong S, Nguyen TH, Plewa MJ. Comparative mammalian cell cytotoxicity of wastewater with elevated bromide and iodide after chlorination, chloramination, or ozonation. J Environ Sci (China) 2017; 58:296-301. [PMID: 28774620 DOI: 10.1016/j.jes.2017.03.030] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 03/11/2017] [Accepted: 03/16/2017] [Indexed: 06/07/2023]
Abstract
Recycling wastewater is becoming more common as communities around the world try to better control their water resources against an increased frequency of either prolonged droughts or intense flooding. For communities in coastal areas, wastewaters may contain elevated levels of bromide (Br-) and iodide (I-) from seawater intrusion or high mineral content of source waters. Disinfection of such wastewater is mandatory to prevent the spread of pathogens, however little is known about the toxicity of wastewater after disinfection in the presence of Br- and I-. In this study we compared the induction of chronic cytotoxicity in mammalian cells in samples of municipal secondary wastewater effluent amended with elevated levels of Br-/I- after disinfection by chlorine, chloramines or ozone to identify which disinfection process generated wastewater with the lowest level of adverse biological response. Chlorination increased mammalian cell cytotoxicity by 5 times as compared to non-disinfected controls. Chloramination produced disinfected wastewater that expressed 6.3 times more cytotoxicity than the non-disinfected controls and was 1.3 times more cytotoxic than the chlorinated samples. Ozonation produced wastewater with cytotoxicity comparable to the non-disinfected controls and was at least 4 times less cytotoxic than the chlorine disinfected wastewaters. These results indicate that compared to chlorination and chloramination, ozonation of wastewater with high Br-/I- levels yielded the lowest mammalian cell cytotoxicity, suggesting its potential as a more favorable method to disinfect wastewater with minimizing the biological toxicity in mind.
Collapse
Affiliation(s)
- Shengkun Dong
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA; Safe Global Water Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA; Safe Global Water Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Michael J Plewa
- Department of Crop Sciences, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA; Safe Global Water Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
17
|
Xie Y, Chen L, Liu R. AOX contamination status and genotoxicity of AOX-bearing pharmaceutical wastewater. J Environ Sci (China) 2017; 52:170-177. [PMID: 28254035 DOI: 10.1016/j.jes.2016.04.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 04/19/2016] [Accepted: 04/27/2016] [Indexed: 06/06/2023]
Abstract
Adsorbable organic halogens (AOX) are a general indicator for the total amount of compounds containing organically bonded halogens. AOX concentrations and components were investigated along the wastewater treatment process in four large-scale pharmaceutical factories of China, and genotoxicity based on the SOS/umu test was also evaluated. The results showed that AOX concentrations in wastewater of four factories ranged from 4.6 to 619.4mg/L, which were high but greatly different owing to differences in the raw materials and products. The wastewater treatment process removed 50.0%-89.9% of AOX, leaving 1.3-302.5mg/L AOX in the effluents. Genotoxicity levels ranged between 2.1 and 68.0μg 4-NQO/L in the raw wastewater and decreased to 1.2-41.2μg 4-NQO/L in the effluents of the wastewater treatment plants (WWTPs). One of the main products of factory I, ciprofloxacin, was identified as the predominant contributor to its genotoxicity. However, for the other three factories, no significant relationship was observed between genotoxicity and detected AOX compounds.
Collapse
Affiliation(s)
- Yawei Xie
- School of Environment, Tsinghua University, Beijing 100084, China.
| | - Lujun Chen
- School of Environment, Tsinghua University, Beijing 100084, China; Zhejiang Provincial Key Laboratory of Water Science and Technology, Zhejiang 314006, China.
| | - Rui Liu
- Zhejiang Provincial Key Laboratory of Water Science and Technology, Zhejiang 314006, China.
| |
Collapse
|
18
|
Ma XY, Wang XC, Wang D, Ngo HH, Zhang Q, Wang Y, Dai D. Function of a landscape lake in the reduction of biotoxicity related to trace organic chemicals from reclaimed water. JOURNAL OF HAZARDOUS MATERIALS 2016; 318:663-670. [PMID: 27475464 DOI: 10.1016/j.jhazmat.2016.07.050] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 07/15/2016] [Accepted: 07/20/2016] [Indexed: 06/06/2023]
Abstract
The storage of water in a landscape lake can act as a buffer zone between reclaimed water production and reuse, but there is still uncertainty about the variation of water quality and toxic effects during the open-storage process. In this study, long-term sample collection, chemical analyses and biotoxicity assessments were conducted on reclaimed water before and after open storage in a landscape lake. The organic contents, in terms of chemical oxygen demand and total organic carbon, were found to be slightly higher in the lake water than that in the reclaimed water, but substantial reduction of the total concentration of 52 trace organic chemicals was obtained and microorganism toxicity, phytotoxicity, aquatic vertebrate toxicity and genotoxicity, were significantly weakened after open storage. Furthermore, the total risk quotient (RQTotal) decreased from 5.12 (potential ecological risk level) in the reclaimed water to 0.18 (negligible ecological risk level) in the lake water. The removal of chlorpyrifos, dichlorphos and tetracycline was identified as the main reason for biotoxicity reduction after open storage. The seminatural environment of the landscape lake would have provided a favorable condition for the decay of toxic trace organic chemicals so that the stored water turned to be safer for further reuse.
Collapse
Affiliation(s)
- Xiaoyan Y Ma
- International Science & Technology Cooperation Center for Urban Alternative Water Resources Development; Key Lab of Northwest Water Resource, Environment and Ecology, MOE; Engineering Technology Research Center for Wastewater Treatment and Reuse; Key Lab of Environmental Engineering, Shaanxi Province; Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Xiaochang C Wang
- International Science & Technology Cooperation Center for Urban Alternative Water Resources Development; Key Lab of Northwest Water Resource, Environment and Ecology, MOE; Engineering Technology Research Center for Wastewater Treatment and Reuse; Key Lab of Environmental Engineering, Shaanxi Province; Xi'an University of Architecture and Technology, Xi'an, 710055, PR China.
| | - Donghong Wang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China
| | - Huu Hao Ngo
- School of Civil and Environmental Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, Broadway, NSW 2007, Australia
| | - Qiuya Zhang
- International Science & Technology Cooperation Center for Urban Alternative Water Resources Development; Key Lab of Northwest Water Resource, Environment and Ecology, MOE; Engineering Technology Research Center for Wastewater Treatment and Reuse; Key Lab of Environmental Engineering, Shaanxi Province; Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Yongkun Wang
- International Science & Technology Cooperation Center for Urban Alternative Water Resources Development; Key Lab of Northwest Water Resource, Environment and Ecology, MOE; Engineering Technology Research Center for Wastewater Treatment and Reuse; Key Lab of Environmental Engineering, Shaanxi Province; Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Dinan Dai
- International Science & Technology Cooperation Center for Urban Alternative Water Resources Development; Key Lab of Northwest Water Resource, Environment and Ecology, MOE; Engineering Technology Research Center for Wastewater Treatment and Reuse; Key Lab of Environmental Engineering, Shaanxi Province; Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| |
Collapse
|
19
|
Hu HY, Du Y, Wu QY, Zhao X, Tang X, Chen Z. Differences in dissolved organic matter between reclaimed water source and drinking water source. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 551-552:133-142. [PMID: 26874770 DOI: 10.1016/j.scitotenv.2015.12.111] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2015] [Revised: 12/22/2015] [Accepted: 12/22/2015] [Indexed: 06/05/2023]
Abstract
Dissolved organic matter (DOM) significantly affects the quality of reclaimed water and drinking water. Reclaimed water potable reuse is an effective way to augment drinking water source and de facto reuse exists worldwide. Hence, when reclaimed water source (namely secondary effluent) is blended with drinking water source, understanding the difference in DOM between drinking water source (dDOM) and reclaimed water source (rDOM) is essential. In this study, composition, transformation, and potential risk of dDOM from drinking water source and rDOM from secondary effluent were compared. Generally, the DOC concentration of rDOM and dissolved organic nitrogen (DON) content in reclaimed water source were higher but rDOM exhibited a lower aromaticity. Besides, rDOM comprises a higher proportion of hydrophilic fractions and more low-molecular weight compounds, which are difficult to be removed during coagulation. Although dDOM exhibited higher specific disinfection byproducts formation potential (SDBPFP), rDOM formed more total disinfection byproducts (DBPs) during chlorination including halomethanes (THMs) and haloacetic acids (HAAs) due to high DOC concentration. Likewise, in consideration of DOC basis, rDOM contained more absolute assimilable organic carbon (AOC) despite showing a lower specific AOC (normalized AOC per unit of DOC). Besides, rDOM exhibited higher biotoxicity including genotoxicity and endocrine disruption. Therefore, rDOM presents a greater potential risk than dDOM does. Reclaimed water source needs to be treated carefully when it is blended with drinking water source.
Collapse
Affiliation(s)
- Hong-Ying Hu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Ye Du
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| | - Qian-Yuan Wu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China.
| | - Xin Zhao
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
| | - Xin Tang
- Southwest Branch of State Grid Corporation of China, Chengdu 610094, China
| | - Zhuo Chen
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, China
| |
Collapse
|
20
|
Zou XL. Combination of ozonation, activated carbon, and biological aerated filter for advanced treatment of dyeing wastewater for reuse. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2015; 22:8174-8181. [PMID: 25843826 DOI: 10.1007/s11356-015-4423-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2014] [Accepted: 03/20/2015] [Indexed: 06/04/2023]
Abstract
Laboratorial scale experiments were performed to investigate and evaluate the performance and removal characteristics of organics, color, and genotoxicity by an integrated process including ozonation, activated carbon (AC), and biological aerated filter (BAF) for recycling biotreated dyeing wastewater (BTDW) collected from a cotton textile factory. Influent chemical oxygen demand (COD) in the range of 156 - 252 mg/L, 5-day biochemical oxygen demand (BOD5) of 13.5 - 21.7 mg/L, and color of 58 - 76° were observed during the 20-day continuous operation. Outflows with average COD of 43 mg/L, BOD5 of 6.6 mg/L, and color of 5.6° were obtained after being decontaminated by the hybrid system with ozone dosage of 0.25 mg O3applied/mg COD0, 40 min ozonation contact time, 30 min hydraulic retention time (HRT) for AC treatment, and 2.5 h HRT for BAF treatment. More than 82 % of the genotoxicity of BTDW was eliminated in the ozonation unit. The genotoxicity of the BAF effluent was less than 1.33 μg 4-nitroquinoline-N-oxide/L. Ozonation could change the organics molecular structures, destroy chromophores, increase the biodegradability, and obviously reduce the genotoxicity of BTDW. Results showed that the combined process could guarantee water reuse with high quality.
Collapse
Affiliation(s)
- Xiao-Ling Zou
- School of Civil Engineering and Architecture, East China Jiaotong University, Nanchang, 330013, Jiangxi, China,
| |
Collapse
|
21
|
Tian Z, Oda Y, Zhang Y, Yang M, Li H. Use of a new enzyme extraction system to improve the sensitivity of SOS/umu test and application to environmental samples. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2015; 94:370-375. [PMID: 25542254 DOI: 10.1007/s00128-014-1445-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2014] [Accepted: 12/16/2014] [Indexed: 06/04/2023]
Abstract
The purpose of this study was to find a better enzyme extraction reagent for the SOS/umu test to replace the conventional one (the combination of sodium dodecyl sulfate (SDS) and Z-buffer), which has the disadvantage of denaturing β-galactosidase leading to decreased measurement sensitivity. By adopting a microplate system, the performance of the umu test using BugBuster Master Mix, a commercially available enzyme extraction reagent, was compared with that using the conventional reagent for detecting the genotoxicity of known mutagens as well as environmental samples. BugBuster Master Mix was found to increase the detection sensitivities of the selected genotoxins and environmental water samples, due to the fact that it doesn't denature β-galactosidase. The result of this study showed that BugBuster Master Mix could be a better enzyme extraction reagent for umu test.
Collapse
Affiliation(s)
- Zhe Tian
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing, 100085, China
| | | | | | | | | |
Collapse
|
22
|
Yang Y, Komaki Y, Kimura SY, Hu HY, Wagner ED, Mariñas BJ, Plewa MJ. Toxic impact of bromide and iodide on drinking water disinfected with chlorine or chloramines. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:12362-9. [PMID: 25222908 DOI: 10.1021/es503621e] [Citation(s) in RCA: 162] [Impact Index Per Article: 16.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Disinfectants inactivate pathogens in source water; however, they also react with organic matter and bromide/iodide to form disinfection byproducts (DBPs). Although only a few DBP classes have been systematically analyzed for toxicity, iodinated and brominated DBPs tend to be the most toxic. The objectives of this research were (1) to determine if monochloramine (NH2Cl) disinfection generated drinking water with less toxicity than water disinfected with free chlorine (HOCl) and (2) to determine the impact of added bromide and iodide in conjunction with HOCl or NH2Cl disinfection on mammalian cell cytotoxicity and genomic DNA damage induction. Water disinfected with chlorine was less cytotoxic but more genotoxic than water disinfected with chloramine. For both disinfectants, the addition of Br(-) and I(-) increased cytotoxicity and genotoxicity with a greater response observed with NH2Cl disinfection. Both cytotoxicity and genotoxicity were highly correlated with TOBr and TOI. However, toxicity was weakly and inversely correlated with TOCl. Thus, the forcing agents for cytotoxicity and genotoxicity were the generation of brominated and iodinated DBPs rather than the formation of chlorinated DBPs. Disinfection practices need careful consideration especially when using source waters containing elevated bromide and iodide.
Collapse
Affiliation(s)
- Yang Yang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, School of Environment, Tsinghua University , Beijing, P.R. China
| | | | | | | | | | | | | |
Collapse
|
23
|
Wu QY, Tang X, Huang H, Li Y, Hu HY, Ding YN, Shao YR. Antiestrogenic activity and related disinfection by-product formation induced by bromide during chlorine disinfection of sewage secondary effluent. JOURNAL OF HAZARDOUS MATERIALS 2014; 273:280-286. [PMID: 24751494 DOI: 10.1016/j.jhazmat.2014.03.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Revised: 01/28/2014] [Accepted: 03/19/2014] [Indexed: 06/03/2023]
Abstract
Chlorine disinfection, widely used in wastewater reclamation, can form toxic and harmful disinfection by-products (DBPs), some of which are associated with endocrine disruption. In this study, the presence of bromide was found to promote an increase in antiestrogenic activity using a yeast two-hybrid assay in the sewage secondary effluent during chlorine disinfection. Among the dissolved organic matters in the secondary effluent, hydrophobic acids and hydrophilic substance fractions were determined as potential precursors associated with increase in antiestrogenic activity in the secondary effluent induced by bromide. Further antiestrogenic activity evaluation and mass spectrum characterization following the semipreparative liquid chromatography fractionation of a natural organic matter precursor, tyrosine, after chlorination under the presence of bromide revealed, for the first time, that 2-(bromo-4-hydroxyphenyl) acetonitrile (Br-HPAN) and 2-(dibromo-4-hydroxyphenyl) acetonitrile (DBr-HPAN) exhibited antiestrogenic activity. Br-HPAN and DBr-HPAN were the DBPs involved in the increase in antiestrogenic activity in the tyrosine solution. Bromide was shown to induce the formation of Br-HPAN and DBr-HPAN in the secondary effluent during chlorine disinfection.
Collapse
Affiliation(s)
- Qian-Yuan Wu
- Shenzhen Laboratory of Microorganism Application and Risk Control, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China
| | - Xin Tang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, and State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Huang Huang
- Environmental Simulation and Pollution Control State Key Joint Laboratory, and State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Yi Li
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Nanjing 210098, PR China
| | - Hong-Ying Hu
- Shenzhen Laboratory of Microorganism Application and Risk Control, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China; Environmental Simulation and Pollution Control State Key Joint Laboratory, and State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China.
| | - Ya-Nan Ding
- Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Ministry of Education, College of Environment, Hohai University, Nanjing 210098, PR China; Nanjing Institute of Environmental Sciences, Ministry of Environmental Protection, Nanjing 210042, PR China
| | - Yi-Ru Shao
- Shenzhen Laboratory of Microorganism Application and Risk Control, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China
| |
Collapse
|
24
|
Zhang H, Yang L, Yu Z, Huang Q. Inactivation of Microcystis aeruginosa by DC glow discharge plasma: Impacts on cell integrity, pigment contents and microcystins degradation. JOURNAL OF HAZARDOUS MATERIALS 2014; 268:33-42. [PMID: 24468526 DOI: 10.1016/j.jhazmat.2014.01.001] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2013] [Revised: 12/14/2013] [Accepted: 01/01/2014] [Indexed: 06/03/2023]
Abstract
We proposed a method to inactivate M. aeruginosa by using discharge plasma taking at the gas-solution interface supplied by DC power. Multiple analysis techniques including fluorescence excitation-emission matrix (EEM) and flow cytometry (FCM) were used to reveal the inactivation mechanism of M. aeruginosa. The photosynthetic pigment contents including phycocyanin, chlorophyll and metabolites were examined quantitatively. The DC glow discharge plasma caused an increased level of reactive oxygen species (ROS), and the damage of M. aeruginosa cells are mainly attributed to the oxidative stress including OH attack and H2O2 oxidation. Our findings demonstrate that plasma oxidation is a promising technology for inactivation of M. aeruginosa cells with simultaneous removal of microcystins and so it may lead us to a new route to efficient treatment of cyanobacterial blooms.
Collapse
Affiliation(s)
- Hong Zhang
- Key Laboratory of Ion Beam Bioengineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, PR China
| | - Linfang Yang
- Key Laboratory of Ion Beam Bioengineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, PR China
| | - Zengliang Yu
- Key Laboratory of Ion Beam Bioengineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, PR China
| | - Qing Huang
- Key Laboratory of Ion Beam Bioengineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences, PR China; University of Science & Technology of China, Hefei, Anhui, 230026, PR China.
| |
Collapse
|
25
|
Li L, Wei D, Wei G, Du Y. Transformation of cefazolin during chlorination process: products, mechanism and genotoxicity assessment. JOURNAL OF HAZARDOUS MATERIALS 2013; 262:48-54. [PMID: 24007998 DOI: 10.1016/j.jhazmat.2013.08.029] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 07/27/2013] [Accepted: 08/12/2013] [Indexed: 05/27/2023]
Abstract
Large quantities of cephalosporins have entered into aquatic environment in recent years, posing potential adverse effect to human health and ecological safety. In this study, cefazolin, one of widely used cephalosporins, was targeted to explore its transformation behaviors in chlorination disinfection process. With the help of ultra high performance liquid chromatography and high resolution mass spectroscopy, one chlorinated product and four oxidation products were detected in cefazolin chlorination system. The corresponding transformation pathways of cefazolin were proposed. Two kinds of reactions occurred in chlorination system, one was oxidation of thioether-sulfur to sulfoxide and di-sulfoxide, and the other was base-catalyzed electrophilic substitution of alpha-H of amide by chlorine atom. The pH value determined the occurrence of reaction types, and increasing chlorine dose promoted transformation of cefazolin. More importantly, genotoxicity in SOS/umu assay had an elevation after chlorination, which might be attributed to the formation of chlorinated product and sulfoxide during chlorination process.
Collapse
Affiliation(s)
- Liping Li
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, PR China.
| | | | | | | |
Collapse
|
26
|
Zhang X, Zhao X. Ecotoxicity assessment of artificial groundwater recharge with reclaimed water: a pilot-scale study. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY 2013; 91:499-502. [PMID: 24072260 DOI: 10.1007/s00128-013-1109-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2012] [Accepted: 09/12/2013] [Indexed: 06/02/2023]
Abstract
A demonstration of artificial groundwater recharge with tertiary effluent was evaluated using a set of bioassays (acute toxicity to Daphnia, genotoxicity, estrogenic and antiestrogenic toxicity). Around 95 % genotoxicity and 53 % antiestrogenicity were removed from the feed water by ozonation, whereas significant reduction of acute toxicity to Daphnia magna was achieved during a 3 days vadose soil treatment. The toxicity was further removed to the same level as the local groundwater during a 20 days aquifer soil treatment. The pilot study has shown that ozonation and soil treatments can improve the quality of municipal wastewater treatment plant effluents for possible groundwater recharge purposes.
Collapse
Affiliation(s)
- Xue Zhang
- Laboratory of Environmental Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing, 100084, People's Republic of China,
| | | |
Collapse
|
27
|
Xiao M, Wei D, Yin J, Wei G, Du Y. Transformation mechanism of benzophenone-4 in free chlorine promoted chlorination disinfection. WATER RESEARCH 2013; 47:6223-6233. [PMID: 23953088 DOI: 10.1016/j.watres.2013.07.043] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2013] [Revised: 07/16/2013] [Accepted: 07/26/2013] [Indexed: 06/02/2023]
Abstract
The UV-filter BP-4 (2-hydroxy-4-methoxybenzophenone-5-sulfonic acid) has been frequently observed in the environment, showing high potentials to invade drinking water, swimming water, or wastewater reclamation treatment systems. With the help of high performance liquid chromatography-high resolution mass spectrometry and nuclear magnetic resonance spectroscopy, 10 new products from free chlorine-promoted BP-4 disinfection have been disclosed and their possible transformation routes have been investigated. The first route is chlorine substitution of BP-4 and its transformation products, forming mono-, di-, and tri-chlorinated BP-4 analogs. The second is Baeyer-Villiger-Type oxidation, converting diphenyl ketone to phenyl ester derivatives. The third is ester hydrolysis, generating corresponding phenolic and benzoic products. The fourth is decarboxylation, replacing the carboxyl group by chloride in the benzoic-type intermediate. The fifth is desulfonation, degrading the sulfonic group through an alternative chlorine substitution on the benzene ring. Orthogonal experiments have been established to investigate the species transformed from BP-4 at different pH values and free available chlorine (FAC) dosages. The reaction pathways are strongly dependent on pH conditions, while an excessive amount of FAC eliminates BP-4 to the smaller molecules. The initial transformation of BP-4 in chlorination system follows pseudo-first-order kinetics, and its half-lives ranged from 7.48 s to 1.26 × 10(2) s. More importantly, we have observed that the FAC-treated BP-4 aqueous solution might increase the genotoxic potentials due to the generation of chlorinated disinfection by-products.
Collapse
Affiliation(s)
- Ming Xiao
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100084, PR China; University of Chinese Academy of Sciences, Beijing 100049, PR China.
| | | | | | | | | |
Collapse
|
28
|
Tang F, Hu HY, Wu QY, Tang X, Sun YX, Shi XL, Huang JJ. Effects of chemical agent injections on genotoxicity of wastewater in a microfiltration-reverse osmosis membrane process for wastewater reuse. JOURNAL OF HAZARDOUS MATERIALS 2013; 260:231-237. [PMID: 23770616 DOI: 10.1016/j.jhazmat.2013.05.035] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2013] [Revised: 05/04/2013] [Accepted: 05/20/2013] [Indexed: 06/02/2023]
Abstract
With combined microfiltration (MF)/ultrafiltration (UF) and reverse osmosis (RO) process being widely used in municipal wastewater reclamation, RO concentrate with high level genotoxicity is becoming a potential risk to water environment. In this study, wastewater genotoxicity in a MF-RO process for municipal wastewater reclamation and also the effects of chemical agent injections were evaluated by SOS/umu genotoxicity test. The genotoxicity of RO concentrate ranged 500-559 μg 4-NQO (4-nitroquinoline-1-oxide)/L and 12-22 μg 4-NQO/mg DOC, was much higher than that of RO influent. Further research suggested that Kathon biocide was a key chemical agent associated with the genotoxicity increase. Kathon biocide used in RO system was highly genotoxic in vitro and Kathon biocide retained in RO system could contribute to a higher genotoxicity of RO concentrate. Hence, treatments for biocides before discharging are necessary. Chlorination of secondary effluent could significantly decrease the genotoxicity and increasing chlorine dosage could be an efficacious method to decrease the genotoxicity of RO concentrate. According to the result of the experiment, the dosage of chlorine in dual-membrane process could be set to about 2.5 mg Cl₂/L. The effect of antiscalant (2-phosphomobutane-1,2,4-tricarboxylic acid) was also investigated; it turned out to have no effect on genotoxicity.
Collapse
Affiliation(s)
- Fang Tang
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing 100084, PR
| | | | | | | | | | | | | |
Collapse
|
29
|
Wu QY, Li Y, Hu HY, Ding YN, Huang H, Zhao FY. Removal of genotoxicity in chlorinated secondary effluent of a domestic wastewater treatment plant during dechlorination. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2012; 19:1-7. [PMID: 21637970 DOI: 10.1007/s11356-011-0535-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2011] [Accepted: 05/23/2011] [Indexed: 05/30/2023]
Abstract
PURPOSE Dechlorination with tetravalent sulfur is widely used in wastewater treatment processes after chlorination. Dechlorination can remove certain genotoxic disinfection by-products (DBPs). However, the reactions occurring during dechlorination of chlorinated secondary effluent and their genotoxic chemicals are still very complex, and the related genotoxicity changes remain unknown. Therefore, the effects of dechlorination on genotoxicity in secondary effluent and its fractions and typical genotoxic chemical after chlorination were evaluated. METHODS The dissolved organic matter in the secondary effluent sample was separated into four fractions with XAD-8 resin. Genotoxicity of secondary effluent and its fractions was evaluated by SOS/umu test, an ISO standard method. The concentration of typical genotoxic chemical named ofloxacin was determined by liquid chromatography with a mass spectrometer and a fluorescence detector. RESULTS Dechlorination with the addition of Na(2)SO(3) notably decreased the genotoxicity in the chlorinated secondary effluent, especially in the presence of high ammonia nitrogen concentration in the sample before chlorination. The Na(2)SO(3) addition significantly decreased the genotoxicity of the secondary effluent and its genotoxic ofloxacin prior to chlorination. The genotoxicity in the fractions containing hydrophobic acids (HOA) increased after chlorination, while addition of Na(2)SO(3) decreased the genotoxicity induced by chlorination. Tryptophan found in HOA exhibited genotoxicity after chlorination, while dechlorination decreased the genotoxicity in chlorinated tryptophan induced by DBPs. CONCLUSIONS Dechlorination was found to decrease the genotoxicity of chlorinated secondary effluent. The decrease was associated with the reduction of genotoxicity in genotoxic chemicals in secondary effluent prior to chlorination and DBPs.
Collapse
Affiliation(s)
- Qian-Yuan Wu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, School of Environment, Tsinghua University, Beijing, People's Republic China.
| | | | | | | | | | | |
Collapse
|
30
|
Lin H, Wang F, Ding L, Hong H, Chen J, Lu X. Enhanced performance of a submerged membrane bioreactor with powdered activated carbon addition for municipal secondary effluent treatment. JOURNAL OF HAZARDOUS MATERIALS 2011; 192:1509-1514. [PMID: 21794980 DOI: 10.1016/j.jhazmat.2011.06.071] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2011] [Revised: 05/28/2011] [Accepted: 06/26/2011] [Indexed: 05/31/2023]
Abstract
The aim of this study was to investigate the feasibility of PAC-MBR process treating municipal secondary effluent. Two laboratory-scale submerged MBRs (SMBR) with and without PAC addition were continuously operated in parallel for secondary effluent treatment. Approximately 63%TOC, 95% NH(4)(+)-N and 98% turbidity in secondary effluent were removed by the PAC-MBR process. Most organics in the secondary effluent were found to be low molecular weight (MW) substances, which could be retained in the reactor and then removed to some extent by using PAC-MBR process. Parallel experiments showed that the addition of PAC significantly increased organic removal and responsible for the largest fraction of organic removal. Membrane fouling analysis showed the enhanced membrane performance in terms of sustainable operational time and filtration resistances by PAC addition. Based on these results, the PAC-MBR process was considered as an attractive option for the reduction of pollutants in secondary effluent.
Collapse
Affiliation(s)
- Hongjun Lin
- College of Geography and Environmental Sciences, Zhejiang Normal University, 688 Yingbin Avenue, Jinhua, Zhejiang Province 321004, PR China.
| | | | | | | | | | | |
Collapse
|
31
|
Wang D, Xu Z, Zhao Y, Yan X, Shi J. Change of genotoxicity for raw and finished water: role of purification processes. CHEMOSPHERE 2011; 83:14-20. [PMID: 21315407 DOI: 10.1016/j.chemosphere.2011.01.039] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/02/2010] [Revised: 01/13/2011] [Accepted: 01/17/2011] [Indexed: 05/30/2023]
Abstract
In China, the safety of drinking water becomes a significant issue due to serious aquatic environmental pollution. The genotoxic levels of raw and finished water from seven typical waterworks located in the five basins in China were then evaluated using umu test. Effect of conventional treatment processes (coagulation, filtration and disinfection) on the genotoxicity and the fate of dissolved organic matter (DOM) was discussed. The results showed that most of the selected finished water presented genotoxicity at or lower than 300 mL water sample exposure dose. The genotoxic effects of finished water were significantly higher than those of raw water. It also exhibited that there existed higher correlation between genotoxic effect and Br(-) than the other water quality parameters. The brominated trihalomethanes played a more important role in finished water genotoxicity than brominated haloacetic acids. The treatment processes could increase the genotoxic effects of finished water, especially for the chlorination treatment. The fluorescence spectra and high performance size-exclusion chromatogram analysis of DOM characters indicated that the proportion of low molecular weight acids, nitrogen containing aromatics, proteinaceous and microbially derived organic matters (200-300 Da) increased during purification processes, which indicated probably the release or formation of drinking water genotoxins.
Collapse
Affiliation(s)
- Dongsheng Wang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| | | | | | | | | |
Collapse
|