1
|
Al-Rubaiey S, Senger C, Bukatz J, Krantchev K, Janas A, Eitner C, Nieminen-Kelhä M, Brandenburg S, Zips D, Vajkoczy P, Acker G. Determinants of cerebral radionecrosis in animal models: A systematic review. Radiother Oncol 2024; 199:110444. [PMID: 39067705 DOI: 10.1016/j.radonc.2024.110444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 06/13/2024] [Accepted: 07/11/2024] [Indexed: 07/30/2024]
Abstract
BACKGROUND Radionecrosis is a common complication in radiation oncology, while mechanisms and risk factors have yet to be fully explored. We therefore conducted a systematic review to understand the pathogenesis and identify factors that significantly affect the development. METHODS We performed a systematic literature search based on the PRISMA guidelines using PubMed, Ovid, and Web of Science databases. The complete search strategy can be found as a preregistered protocol on PROSPERO (CRD42023361662). RESULTS We included 83 studies, most involving healthy animals (n = 72, 86.75 %). High doses of hemispherical irradiation of 30 Gy in rats and 50 Gy in mice led repeatedly to radionecrosis among different studies and set-ups. Higher dose and larger irradiated volume were associated with earlier onset. Fractionated schedules showed limited effectiveness in the prevention of radionecrosis. Distinct anatomical brain structures respond to irradiation in various ways. White matter appears to be more vulnerable than gray matter. Younger age, more evolved animal species, and genetic background were also significant factors, whereas sex was irrelevant. Only 13.25 % of the studies were performed on primary brain tumor bearing animals, no studies on brain metastases are currently available. CONCLUSION This systematic review identified various factors that significantly affect the induction of radionecrosis. The current state of research neglects the utilization of animal models of brain tumors, even though patients with brain malignancies constitute the largest group receiving brain irradiation. This latter aspect should be primarily addressed when developing an experimental radionecrosis model for translational implementation.
Collapse
Affiliation(s)
- Sanaria Al-Rubaiey
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany; Department of Radiation Oncology, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| | - Carolin Senger
- Department of Radiation Oncology, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| | - Jan Bukatz
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany; Department of Radiation Oncology, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| | - Kiril Krantchev
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Anastasia Janas
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany; Berlin Institute of Health at Charité, Universitätsmedizin Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Chiara Eitner
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Melina Nieminen-Kelhä
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Susan Brandenburg
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Daniel Zips
- Department of Radiation Oncology, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| | - Peter Vajkoczy
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany.
| | - Güliz Acker
- Department of Neurosurgery, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Charitéplatz 1 10117, Berlin, Germany; Berlin Institute of Health at Charité, Universitätsmedizin Berlin, Charitéplatz 1 10117, Berlin, Germany; Department of Radiation Oncology, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt- Universität zu Berlin, Augustenburger Platz 1 13353, Berlin, Germany.
| |
Collapse
|
2
|
Pemmasani Prabakaran RS, Park SW, Lai JHC, Wang K, Xu J, Chen Z, Ilyas AMO, Liu H, Huang J, Chan KWY. Deep-learning-based super-resolution for accelerating chemical exchange saturation transfer MRI. NMR IN BIOMEDICINE 2024; 37:e5130. [PMID: 38491754 DOI: 10.1002/nbm.5130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 02/02/2024] [Accepted: 02/05/2024] [Indexed: 03/18/2024]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a molecular imaging tool that provides physiological information about tissues, making it an invaluable tool for disease diagnosis and guided treatment. Its clinical application requires the acquisition of high-resolution images capable of accurately identifying subtle regional changes in vivo, while simultaneously maintaining a high level of spectral resolution. However, the acquisition of such high-resolution images is time consuming, presenting a challenge for practical implementation in clinical settings. Among several techniques that have been explored to reduce the acquisition time in MRI, deep-learning-based super-resolution (DLSR) is a promising approach to address this problem due to its adaptability to any acquisition sequence and hardware. However, its translation to CEST MRI has been hindered by the lack of the large CEST datasets required for network development. Thus, we aim to develop a DLSR method, named DLSR-CEST, to reduce the acquisition time for CEST MRI by reconstructing high-resolution images from fast low-resolution acquisitions. This is achieved by first pretraining the DLSR-CEST on human brain T1w and T2w images to initialize the weights of the network and then training the network on very small human and mouse brain CEST datasets to fine-tune the weights. Using the trained DLSR-CEST network, the reconstructed CEST source images exhibited improved spatial resolution in both peak signal-to-noise ratio and structural similarity index measure metrics at all downsampling factors (2-8). Moreover, amide CEST and relayed nuclear Overhauser effect maps extrapolated from the DLSR-CEST source images exhibited high spatial resolution and low normalized root mean square error, indicating a negligible loss in Z-spectrum information. Therefore, our DLSR-CEST demonstrated a robust reconstruction of high-resolution CEST source images from fast low-resolution acquisitions, thereby improving the spatial resolution and preserving most Z-spectrum information.
Collapse
Affiliation(s)
- Rohith Saai Pemmasani Prabakaran
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong, China
| | - Se Weon Park
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong, China
| | - Joseph H C Lai
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kexin Wang
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland, USA
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Zilin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | | | - Huabing Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Jianpan Huang
- Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong, China
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering, Hong Kong, China
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Tung Biomedical Sciences Centre, Hong Kong, China
- City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| |
Collapse
|
3
|
Kurmi Y, Viswanathan M, Zu Z. Enhancing SNR in CEST imaging: A deep learning approach with a denoising convolutional autoencoder. Magn Reson Med 2024. [PMID: 39030953 DOI: 10.1002/mrm.30228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 05/28/2024] [Accepted: 07/01/2024] [Indexed: 07/22/2024]
Abstract
PURPOSE To develop a SNR enhancement method for CEST imaging using a denoising convolutional autoencoder (DCAE) and compare its performance with state-of-the-art denoising methods. METHOD The DCAE-CEST model encompasses an encoder and a decoder network. The encoder learns features from the input CEST Z-spectrum via a series of one-dimensional convolutions, nonlinearity applications, and pooling. Subsequently, the decoder reconstructs an output denoised Z-spectrum using a series of up-sampling and convolution layers. The DCAE-CEST model underwent multistage training in an environment constrained by Kullback-Leibler divergence, while ensuring data adaptability through context learning using Principal Component Analysis-processed Z-spectrum as a reference. The model was trained using simulated Z-spectra, and its performance was evaluated using both simulated data and in vivo data from an animal tumor model. Maps of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effects were quantified using the multiple-pool Lorentzian fit, along with an apparent exchange-dependent relaxation metric. RESULTS In digital phantom experiments, the DCAE-CEST method exhibited superior performance, surpassing existing denoising techniques, as indicated by the peak SNR and Structural Similarity Index. Additionally, in vivo data further confirm the effectiveness of the DCAE-CEST in denoising the APT and NOE maps when compared with other methods. Although no significant difference was observed in APT between tumors and normal tissues, there was a significant difference in NOE, consistent with previous findings. CONCLUSION The DCAE-CEST can learn the most important features of the CEST Z-spectrum and provide the most effective denoising solution compared with other methods.
Collapse
Affiliation(s)
- Yashwant Kurmi
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Malvika Viswanathan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| |
Collapse
|
4
|
Cai Z, Zhong Q, Feng Y, Wang Q, Zhang Z, Wei C, Yin Z, Liang C, Liew CW, Kazak L, Cypess AM, Liu Z, Cai K. Non-invasive mapping of brown adipose tissue activity with magnetic resonance imaging. Nat Metab 2024; 6:1367-1379. [PMID: 39054361 PMCID: PMC11272596 DOI: 10.1038/s42255-024-01082-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 06/14/2024] [Indexed: 07/27/2024]
Abstract
Thermogenic brown adipose tissue (BAT) has a positive impact on whole-body metabolism. However, in vivo mapping of BAT activity typically relies on techniques involving ionizing radiation, such as [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography (PET) and computed tomography (CT). Here we report a noninvasive metabolic magnetic resonance imaging (MRI) approach based on creatine chemical exchange saturation transfer (Cr-CEST) contrast to assess in vivo BAT activity in rodents and humans. In male rats, a single dose of the β3-adrenoceptor agonist (CL 316,243) or norepinephrine, as well as cold exposure, triggered a robust elevation of the Cr-CEST MRI signal, which was consistent with the [18F]FDG PET and CT data and 1H nuclear magnetic resonance measurements of creatine concentration in BAT. We further show that Cr-CEST MRI detects cold-stimulated BAT activation in humans (both males and females) using a 3T clinical scanner, with data-matching results from [18F]FDG PET and CT measurements. This study establishes Cr-CEST MRI as a promising noninvasive and radiation-free approach for in vivo mapping of BAT activity.
Collapse
Affiliation(s)
- Zimeng Cai
- Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
- School of Medicine, South China University of Technology, Guangzhou, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou, China
| | - Qiaoling Zhong
- Department of Radiology, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, China
| | - Yanqiu Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence & Key Laboratory of Mental Health of the Ministry of Education, Southern Medical University, Guangzhou, China
| | - Qian Wang
- The Biomedical Translational Research Institute, Faculty of Medical Science, Jinan University, Guangzhou, China
| | - Zuoman Zhang
- Department of Neonatology, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Cailv Wei
- School of Medicine, Shenzhen Campus, Sun Yat-sen University, Shenzhen, China
| | - Zhinan Yin
- The Biomedical Translational Research Institute, Faculty of Medical Science, Jinan University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Tumor Interventional Diagnosis and Treatment, Zhuhai Institute of Translational Medicine, Zhuhai People's Hospital Affiliated with Jinan University, Jinan University, Zhuhai, China
| | - Changhong Liang
- Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou, China
| | - Chong Wee Liew
- Physiology and Biophysics Department, University of Illinois at Chicago, Chicago, IL, USA
| | - Lawrence Kazak
- Rosalind & Morris Goodman Cancer Institute, McGill University, Montreal, Quebec, Canada
- Department of Biochemistry, McGill University, Montreal, Quebec, Canada
| | - Aaron M Cypess
- Diabetes, Endocrinology, and Obesity Branch, Intramural Research Program, National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), National Institutes of Health, Bethesda, MD, USA
| | - Zaiyi Liu
- Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
- Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou, China.
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, USA
- Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
5
|
Sun PZ. Quasi-steady-state (QUASS) reconstruction enhances T 1 normalization in apparent exchange-dependent relaxation (AREX) analysis: A reevaluation of T 1 correction in quantitative CEST MRI of rodent brain tumor models. Magn Reson Med 2024; 92:236-245. [PMID: 38380727 PMCID: PMC11055669 DOI: 10.1002/mrm.30056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/26/2024] [Accepted: 02/04/2024] [Indexed: 02/22/2024]
Abstract
PURPOSE The apparent exchange-dependent relaxation (AREX) analysis has been proposed as an effective means to correct T1 contribution in CEST quantification. However, it has been recognized that AREX T1 correction is not straightforward if CEST scans are not performed under the equilibrium condition. Our study aimed to test if quasi-steady-state (QUASS) reconstruction could boost the accuracy of the AREX metric under common non-equilibrium scan conditions. THEORY AND METHODS Numerical simulation and in vivo scans were performed to assess the AREX metric accuracy. The CEST signal was simulated under different relaxation delays, RF saturation amplitudes, and durations. The AREX was evaluated as a function of the bulk water T1 and labile proton concentration using the multiple linear regression model. AREX MRI was also assessed in brain tumor rodent models, with both apparent CEST scans and QUASS reconstruction. RESULTS Simulation showed that the AREX calculation from apparent CEST scans, under non-equilibrium conditions, had significant dependence on labile proton fraction ratio, RF saturation time, and T1. In comparison, QUASS-boosted AREX depended on the labile proton fraction ratio without significant dependence on T1 and RF saturation time. Whereas the apparent (2.7 ± 0.8%) and QUASS MTR asymmetry (2.8 ± 0.8%) contrast between normal and tumor regions of interest (ROIs) were significant, the difference was small. In comparison, AREX contrast between normal and tumor ROIs calculated from the apparent CEST scan and QUASS reconstruction was 3.8 ± 1.1%/s and 4.4 ± 1.2%/s, respectively, statistically different from each other. CONCLUSIONS AREX analysis benefits from the QUASS-reconstructed equilibrium CEST effect for improved T1 correction and quantitative CEST analysis.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA
- Winship Cancer Institute, Emory University, Atlanta, GA
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA
| |
Collapse
|
6
|
Tokunaga C, Wada T, Togao O, Kobayashi K, Kato T. Amide proton transfer-weighted imaging with a short acquisition time based on a self B0 correction using the turbo spin echo-Dixon method: A phantom study. Magn Reson Imaging 2024; 110:69-77. [PMID: 38614223 DOI: 10.1016/j.mri.2024.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 04/06/2024] [Accepted: 04/07/2024] [Indexed: 04/15/2024]
Abstract
PURPOSE Conventional amide proton transfer (APT)-weighted imaging requires a chemical exchange saturation transfer (CEST) sequence with multiple saturation frequency offsets and a B0 correction sequence, plus a long acquisition time that can be reduced by applying the conventional method using CEST images with seven radiation pulses (i.e., the seven-points method). For a further reduction of acquisition times, we propose fast two-dimensional (2D) APT-weighted imaging based on a self B0 correction using the turbo spin echo (TSE)-Dixon method. We conducted a phantom study to investigate the accuracy of TSE-Dixon APT-weighted imaging. METHODS We prepared two types of phantoms with six samples for a concentrationdependent evaluation and a pH-dependent evaluation. APT-weighted images were acquired by the conventional, seven-points, and TSE-Dixon methods. Linear regression analyses assessed the dependence between each method's APT signal intensities (SIs) and the concentration or pH. We performed a one-way analysis of variance with Tukey's honestly significant difference post hoc test to compare the APT SIs among the three methods. The agreement of the APT SIs between the conventional and seven-points or TSE-Dixon methods was assessed by a Bland- Altman plot analysis. RESULTS The APT SIs of all three acquisition methods showed positive concentration dependence and pH dependence. No significant differences were observed in the APT SIs between the conventional and TSE-Dixon methods at each concentration. The Bland-Altman plot analyses showed that the APT SIs measured with the seven-points method resulted in 0.42% bias and narrow 95% limits of agreement (LOA) (0.93%-0.09%) compared to the conventional method. The APT SIs measured using the TSE-Dixon method showed 0.14% bias and similar 95% LOA (-0.33% to 0.61%) compared with the seven-points method. The APT SIs of all three methods showed positive pH dependence. At each pH, no significant differences in the APT SIs were observed among the methods. Bland-Altman plot analyses showed that the APT SIs measured with the seven-points method resulted in low bias (0.03%) and narrow 95% LOA (-0.30% to 0.36%) compared to the conventional method. The APT SIs measured by the TSE-Dixon method showed slightly larger bias (0.29%) and similar 95% LOA (from -0.15% to 0.72%) compared to those measured by the seven-points method. CONCLUSION These results demonstrated that our proposed method has the same concentration dependence and pH dependence as the conventional method and the seven-points method. We thus expect that APT-weighted imaging with less influence of motion can be obtained in clinical examinations.
Collapse
Affiliation(s)
- Chiaki Tokunaga
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Osamu Togao
- Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Kouji Kobayashi
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Toyoyuki Kato
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
7
|
Mohanta Z, Stabinska J, Gilad AA, Barker PB, McMahon MT. The Proton Resonance Enhancement for CEST imaging and Shift Exchange (PRECISE) family of RF pulse shapes for Chemical Exchange Saturation Transfer MRI. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.06.19.599565. [PMID: 38948741 PMCID: PMC11212941 DOI: 10.1101/2024.06.19.599565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/02/2024]
Abstract
Purpose To optimize a 100 msec pulse for producing CEST MRI contrast and evaluate in mice. Methods A gradient ascent algorithm was employed to generate a family of 100 point, 100 msec pulses for use in CEST pulse trains ('PRECISE'). Gradient ascent optimizations were performed for exchange rates (k ca ) = 500 s -1 , 1,500 s -1 , 2,500 s -1 , 3,500 s -1 and 4,500 s -1 and offsets (Δω) = 9.6, 7.8, 4.2 and 2.0 ppm. 7 PRECISE pulse shapes were tested on an 11.7 T scanner using a phantom containing three representative CEST agents with peak saturation B 1 = 4 μT. The pulse producing the most contrast in phantoms was then evaluated for CEST MRI pH mapping of the kidneys in healthy mice after iopamidol administration. Results The most promising pulse in terms of contrast performance across all three phantoms was the 9.6 ppm, 2500 s -1 optimized pulse with ∼2.7 x improvement over Gaussian and ∼1.3x's over Fermi pulses. This pulse also displayed a large improvement in contrast over the Gaussian pulse after administration of iopamidol in live mice. Conclusion A new 100 msec pulse was developed based on gradient ascent optimizations which produced better contrast compared to standard Gaussian and Fermi pulses in phantoms. This shape also showed a substantial improvement for CEST MRI pH mapping in live mice over the Gaussian shape and appears promising for a wide range of CEST applications.
Collapse
|
8
|
Kurmi Y, Viswanathan M, Zu Z. A Denoising Convolutional Autoencoder for SNR Enhancement in Chemical Exchange Saturation Transfer imaging: (DCAE-CEST). BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.06.07.597818. [PMID: 38895366 PMCID: PMC11185751 DOI: 10.1101/2024.06.07.597818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/21/2024]
Abstract
Purpose To develop a SNR enhancement method for chemical exchange saturation transfer (CEST) imaging using a denoising convolutional autoencoder (DCAE), and compare its performance with state-of-the-art denoising methods. Method The DCAE-CEST model encompasses an encoder and a decoder network. The encoder learns features from the input CEST Z-spectrum via a series of 1D convolutions, nonlinearity applications and pooling. Subsequently, the decoder reconstructs an output denoised Z-spectrum using a series of up-sampling and convolution layers. The DCAE-CEST model underwent multistage training in an environment constrained by Kullback-Leibler divergence, while ensuring data adaptability through context learning using Principal Component Analysis processed Z-spectrum as a reference. The model was trained using simulated Z-spectra, and its performance was evaluated using both simulated data and in-vivo data from an animal tumor model. Maps of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effects were quantified using the multiple-pool Lorentzian fit, along with an apparent exchange-dependent relaxation metric. Results In digital phantom experiments, the DCAE-CEST method exhibited superior performance, surpassing existing denoising techniques, as indicated by the peak SNR and Structural Similarity Index. Additionally, in vivo data further confirms the effectiveness of the DCAE-CEST in denoising the APT and NOE maps when compared to other methods. While no significant difference was observed in APT between tumors and normal tissues, there was a significant difference in NOE, consistent with previous findings. Conclusion The DCAE-CEST can learn the most important features of the CEST Z-spectrum and provide the most effective denoising solution compared to other methods.
Collapse
Affiliation(s)
- Yashwant Kurmi
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, USA
| | - Malvika Viswanathan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, USA
| |
Collapse
|
9
|
Kanematsu Y, Kanazawa Y, Shimada K, Korai M, Miyamoto T, Sogabe S, Ishihara M, Yamaguchi I, Oya T, Yamamoto N, Yamamoto Y, Miyoshi M, Harada M, Takagi Y. Characterization of carotid plaques using chemical exchange saturation transfer imaging. Neuroradiology 2024:10.1007/s00234-024-03401-3. [PMID: 38866959 DOI: 10.1007/s00234-024-03401-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Accepted: 06/06/2024] [Indexed: 06/14/2024]
Abstract
PURPOSE The preoperative assessment of carotid plaques is necessary to render revascularization safe and effective. The aim of this study is to evaluate the usefulness of chemical exchange saturation transfer (CEST)-MRI, particularly amide proton transfer (APT) imaging as a preoperative carotid plaque diagnostic tool. METHODS We recorded the APT signal intensity on concentration maps of 34 patients scheduled for carotid endarterectomy. Plaques were categorized into group A (APT signal intensity ≥ 1.90 E-04; n = 12) and group B (APT signal intensity < 1.90 E-04; n = 22). Excised plaques were subjected to histopathological assessment and, using the classification promulgated by the American Heart Association, they were classified as intraplaque hemorrhage-positive [type VI-positive (tVI+)] and -negative [no intraplaque hemorrhage (tVI-)]. RESULTS Of the 34 patients, 22 (64.7%) harbored tVI+- and 12 (35.3%) had tVI- plaques. The median APT signals were significantly higher in tVI+- than tIVI- patients (2.43 E-04 (IQR = 0.98-4.00 E-04) vs 0.54 E-04 (IQR = 0.14-1.09 E-04), p < .001). Histopathologically, the number of patients with tVI+ plaques was significantly greater in group A (100%, n = 12) than group B (45%, n = 22) (p < .01). The number of symptomatic patients or asymptomatic patients with worsening stenosis was also significantly greater in group A than group B (75% vs 36%, p < .01). CONCLUSION In unstable plaques with intraplaque hemorrhage and in patients with symptoms or progressive stenosis, the ATP signals were significantly elevated. CEST-MRI studies has the potential for the preoperative assessment of the plaques' characteristics.
Collapse
Affiliation(s)
- Yasuhisa Kanematsu
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan.
| | - Yuki Kanazawa
- Department of Medical Imaging and Physics, Tokushima University Graduate School of Biomedical Sciences, Tokushima, Japan
| | - Kenji Shimada
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Masaaki Korai
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Takeshi Miyamoto
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Shu Sogabe
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Manabu Ishihara
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Izumi Yamaguchi
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| | - Takeshi Oya
- Department of Molecular Pathology, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Nobuaki Yamamoto
- Department of Clinical Neuroscience, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Yuki Yamamoto
- Department of Clinical Neuroscience, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Mitsuharu Miyoshi
- Global MR Clinical Solutions and Research Collaborations, GE HealthCare, Japan, Hino
| | - Masafumi Harada
- Department of Radiology, Tokushima University Graduate School of Biomedical Sciences, Japan, Tokushima
| | - Yasushi Takagi
- Department of Neurosurgery, Tokushima University Graduate School of Biomedical Sciences, 3-18-15 Kuramoto-Cho, Tokushima, 770-8503, Japan
| |
Collapse
|
10
|
Shaghaghi M, Cai K. Analytical solution of the Bloch-McConnell equations for steady-state CEST Z-spectra. Magn Reson Imaging 2024; 109:74-82. [PMID: 38430977 DOI: 10.1016/j.mri.2024.02.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 02/22/2024] [Accepted: 02/23/2024] [Indexed: 03/05/2024]
Abstract
PURPOSE To derive an analytic expression for the steady-state Chemical Exchange Saturation Transfer (CEST) Z-spectra of a two-pool proton-exchanging system, facilitating simulations and expedited fitting of steady-state Z-spectra. METHOD The analytical expression is derived by directly solving the set of Bloch-McConnell differential equations in matrix form for a two-pool exchanging system, determining water magnetization under steady-state saturation across the entire Z-spectrum. The analytic solution is compared and validated against the numerical solution of Bloch-McConnell equations under prolonged saturation. The study also explores the line shape of a CEST peak, interpolating under-sampled Z-spectra, and Z-spectral fitting in the presence of noise. RESULTS The derived analytic solution accurately reproduces spectra obtained through numerical solutions. Direct fitting of simulated CEST spectra with the analytical solution yields the physical parameters of the exchanging system. The study shows that the analytical solution enables the reproduction of fully sampled spectra from sparsely sampled Z-spectra. Additionally, it confirms the approximation of the CEST spectrum of a single exchanging proton species with a Lorentzian function. Monte Carlo simulations reveal that the accuracy and precision of Z-spectral fittings for physical parameters are significantly influenced by data noise. The study also derives and discusses the analytical solution for three-pool Z-spectra. CONCLUSION The derived analytic solution for steady state Z-spectra can be utilized for simulations and Z-spectrum fitting, significantly reducing fitting times compared to numerical methods employed for fitting CEST Z-spectra.
Collapse
Affiliation(s)
- Mehran Shaghaghi
- Department of Radiology, University of Illinois at Chicago, Chicago, IL 60612, USA
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL 60612, USA; Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA.
| |
Collapse
|
11
|
Frosina G. Advancements in Image-Based Models for High-Grade Gliomas Might Be Accelerated. Cancers (Basel) 2024; 16:1566. [PMID: 38672647 PMCID: PMC11048778 DOI: 10.3390/cancers16081566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 04/08/2024] [Accepted: 04/18/2024] [Indexed: 04/28/2024] Open
Abstract
The first half of 2022 saw the publication of several major research advances in image-based models and artificial intelligence applications to optimize treatment strategies for high-grade gliomas, the deadliest brain tumors. We review them and discuss the barriers that delay their entry into clinical practice; particularly, the small sample size and the heterogeneity of the study designs and methodologies used. We will also write about the poor and late palliation that patients suffering from high-grade glioma can count on at the end of life, as well as the current legislative instruments, with particular reference to Italy. We suggest measures to accelerate the gradual progress in image-based models and end of life care for patients with high-grade glioma.
Collapse
Affiliation(s)
- Guido Frosina
- Mutagenesis & Cancer Prevention Unit, IRCCS Ospedale Policlinico San Martino, Largo Rosanna Benzi 10, 16132 Genova, Italy
| |
Collapse
|
12
|
Pahwa B, Shukla A. Role and contributions of women in revolutionizing neurosurgery. World Neurosurg X 2024; 22:100284. [PMID: 38444868 PMCID: PMC10914579 DOI: 10.1016/j.wnsx.2024.100284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Accepted: 02/20/2024] [Indexed: 03/07/2024] Open
Abstract
We owe it to the women neurosurgeons for paving the way to a more gender-inclusive world of medicine. Their dedication and sacrifices have led them and their followers to scale unimaginable heights in terms of administrative positions, leadership, and academics. In today's scenario, it is safe to say that society has progressed considerably. Past years have seen an uprise in the number of females enrolling in a medical degree programme however, this proportion is highly distorted when it comes to specialties such as Neurosurgery. This disparity seems to be evolving and leveling out in all specialties, as more and more women are stepping out of their comfort zone and challenging the established standards of the society. It is with the collective efforts of all stakeholders and women that we see more women not only choosing such specialties which were previously uncharted terrain, but also leading organizations globally and excelling on the administrative and academic fronts. Veteran female surgeons have revolutionized neurosurgery and its subspecialties in unimaginable ways and the present as well as the future generation neurosurgeons continue to take inspiration from them and follow their footsteps. This paper has put together the contributions of female neurosurgeons in various subspecialties of neurosurgery as well as giving an account of the leadership and administrative positions served by women. We also shed light on the role of women as an academician and a researcher.
Collapse
Affiliation(s)
- Bhavya Pahwa
- University College of Medical Sciences, Delhi, India
| | | |
Collapse
|
13
|
Jin T, Chung JJ. Adjustment of rotation and saturation effects (AROSE) for CEST imaging. Magn Reson Med 2024; 91:1016-1029. [PMID: 38009992 PMCID: PMC10841829 DOI: 10.1002/mrm.29938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 10/09/2023] [Accepted: 11/06/2023] [Indexed: 11/29/2023]
Abstract
PURPOSE Endogenous CEST signal usually has low specificity due to contaminations from the magnetization transfer contrast (MTC) and other labile protons with overlapping or close Larmor frequencies. We propose to improve CEST signal specificity with adjustment of rotation and saturation effects (AROSE). METHODS The AROSE approach measures the difference between CEST signals acquired with the same average irradiation power but largely different duty cycles, for example, a continuous wave or a high duty cycle pulse train versus a low duty cycle pulse train with a flip angle φ. Simulation, phantom, and in vivo rodent studies were performed to evaluate the characteristics of the AROSEφ signal. RESULTS Simulation and experimental results show that AROSE2π is a low-pass filter that can suppress fast exchanging processes (e.g., >3000 s-1 ), whereas AROSEπ is a band-pass filter suppressing both fast and slow exchange (e.g., <30 s-1 ) rates. For other φ angles, the sensitivity and the exchange-rate filtering effect of AROSEφ falls between AROSEπ and AROSE2π . AROSE can also minimize MTC and improve the Larmor frequency selectivity of the CEST signal. The linewidth of the AROSE1.5π spectrum is about 60% to 65% when compared to the CEST spectrum measured by continuous wave. Depending on the needs of an application, the sensitivity, exchange-rate filtering, and Larmor frequency selectivity can be adjusted by varying the flip angle, duty cycle, and average irradiation power. CONCLUSION Compared to conventional CEST signals, AROSE can minimize MTC and improve exchange rate filtering and Larmor frequency specificity.
Collapse
Affiliation(s)
- Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Julius Juhyun Chung
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
14
|
Donahue MJ, Donahue PMC, Jones RS, Garza M, Lee C, Patel NJ, Cooper A, De Vis JB, Meszoely I, Crescenzi R. In vivo lymph node CEST-Dixon MRI in breast cancer patients with metastatic lymph node involvement. Magn Reson Med 2024; 91:670-680. [PMID: 37684712 DOI: 10.1002/mrm.29858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 08/19/2023] [Accepted: 08/21/2023] [Indexed: 09/10/2023]
Abstract
PURPOSE Axillary lymph nodes (LNs) often present a reservoir for metastatic breast cancer, yet metastatic LN involvement cannot be discerned definitively using diagnostic imaging. This study investigated whether in vivo CEST may discriminate LNs with versus without metastatic involvement. METHODS 3T MRI was performed in patients with breast cancer before clinically-indicated mastectomy or lumpectomy with LN removal, after which LN metastasic involvement was determined using histological evaluation. Non-contrast anatomical imaging, as well as B0 and B1 field maps, were acquired in sequence with three-point CEST-Dixon (3D turbo-gradient-echo; factor = 25; TR/TE1/ΔTE = 851/1.35/1.1 ms; spatial-resolution = 2.5 × 2.5 × 6 mm; slices = 10; four sinc-gauss pulses with duty-cycle = 0.5, total saturation duration = 701.7 ms; B1 = 1.5 μT; saturation offsets = -5.5 to +5.5 ppm; stepsize = 0.2 ppm; scan duration = 6 min 30 s). The mean z-spectrum from LNs with (n = 20) versus without (n = 22) metastatic involvement were analyzed and a Wilcoxon rank-sum test (significance: p < 0.05) was applied to evaluate differences in B0, B1 , and magnetization transfer ratio (MTR) in differing spectral regions of known proton exchange (nuclear Overhauser effect [NOE], amide, amine, and hydroxyl) between cohorts. RESULTS No difference in axillary B1 (p = 0.634) or B0 (p = 0.689) was observed between cohorts. Elevated MTR was observed for the NOE (-1.7 ppm; MTR = 0.285 ± 0.075 vs. 0.248 ± 0.039; p = 0.048), amine (+2.5 ppm; MTR = 0.284 ± 0.067 vs. 0.234 ± 0.31; p = 0.005), and hydroxyl (+1 ppm; MTR = 0.394 ± 0.075 vs. 0.329 ± 0.055; p = 0.002) protons in LNs from participants with versus without metastatic involvement. CONCLUSIONS Findings are consistent with a unique metastatic LN microenvironment detectable by CEST-Dixon and suggest that CEST MRI may have potential for mapping LN metastasis non-invasively in vivo.
Collapse
Affiliation(s)
- Manus J Donahue
- Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Psychiatry and Behavioral Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Paula M C Donahue
- Department of Physical Medicine and Rehabilitation, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Dayani Center for Health and Wellness, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - R Sky Jones
- Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Maria Garza
- Department of Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Chelsea Lee
- Department of Pediatric Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Niral J Patel
- Department of Pediatric Neurology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | | | - Jill B De Vis
- Department of Radiation Oncology, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Ingrid Meszoely
- Department of Surgery, Division of Surgical Oncology and Endocrine Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Rachelle Crescenzi
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| |
Collapse
|
15
|
Viswanathan M, Kurmi Y, Zu Z. Nuclear Overhauser enhancement imaging at -1.6 ppm in rat brain at 4.7T. Magn Reson Med 2024; 91:615-629. [PMID: 37867419 DOI: 10.1002/mrm.29896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Revised: 09/21/2023] [Accepted: 10/04/2023] [Indexed: 10/24/2023]
Abstract
PURPOSE A new nuclear Overhauser enhancement (NOE)-mediated saturation transfer signal at around -1.6 ppm, termed NOE(-1.6), has been reported at high fields of 7T and 9.4T previously. This study aims to validate the presence of this signal at a relatively low field of 4.7T and evaluate its variations in different brain regions and tumors. METHODS Rats were injected with monocrystalline iron oxide nanoparticles to reduce the NOE(-1.6) signal. CEST signals were measured using different saturation powers before and after injection to assess the presence of this signal. Multiple-pool Lorentzian fits, with/without inclusion of the NOE(-1.6) pool, were performed on CEST Z-spectra obtained from healthy rat brains and rats with 9L tumors. These fits aimed to further validate the presence of the NOE(-1.6) signal and quantify its amplitude. RESULTS The NOE(-1.6) signal exhibited a dramatic change following the injection of monocrystalline iron oxide nanoparticles, confirming its presence at 4.7T. The NOE(-1.6) signal reached its peak at a saturation power of ∼0.75 μT, indicating an optimized power level. The multiple-pool Lorentzian fit without the NOE(-1.6) pool showed higher residuals around -1.6 ppm compared to the fit with this pool, further supporting the presence of this signal. The NOE(-1.6) signal did not exhibit significant variation in the corpus callosum and caudate putamen regions, but it showed a significant decrease in tumors, which aligns with previous findings at 9.4T. CONCLUSION This study successfully demonstrated the presence of the NOE(-1.6) signal at 4.7T, which provides valuable insights into its potential applications at lower field strengths.
Collapse
Affiliation(s)
- Malvika Viswanathan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Yashwant Kurmi
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA
- Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
16
|
Kim H, Park S, Hu R, Hoang KB, Sun PZ. 3D CEST MRI with an unevenly segmented RF irradiation scheme: A feasibility study in brain tumor imaging. Magn Reson Med 2023; 90:2400-2410. [PMID: 37526017 PMCID: PMC10586718 DOI: 10.1002/mrm.29810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 06/17/2023] [Accepted: 07/08/2023] [Indexed: 08/02/2023]
Abstract
PURPOSE To integrate 3D CEST EPI with an unevenly segmented RF irradiation module and preliminarily demonstrate it in the clinical setting. METHODS A CEST MRI with unevenly segmented RF saturation was implemented, including a long primary RF saturation to induce the steady-state CEST effect, maintained with repetitive short secondary RF irradiation between readouts. This configuration reduces relaxation-induced blur artifacts during acquisition, allowing fast 3D spatial coverage. Numerical simulations were performed to select parameters such as flip angle (FA), short RF saturation duration (Ts2), and the number of readout segments. The sequence was validated experimentally with data from a phantom, healthy volunteers, and a brain tumor patient. RESULTS Based on the numerical simulation and l-carnosine gel phantom experiment, FA, Ts2, and the number of segments were set to 20°, 0.3 s, and the range from 4 to 8, respectively. The proposed method minimized signal modulation in the human brain images in the kz direction during the acquisition and provided the blur artifacts-free CEST contrast over the whole volume. Additionally, the CEST contrast in the tumor tissue region is higher than in the contralateral normal tissue region. CONCLUSIONS It is feasible to implement a highly accelerated 3D EPI CEST imaging with unevenly segmented RF irradiation.
Collapse
Affiliation(s)
- Hahnsung Kim
- Emory National Primate Research Center, Emory University, Atlanta GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta GA
| | - Suhyung Park
- Department of Computer Engineering, Chonnam National University, South Korea
- Department of ICT Convergence System Engineering, Chonnam National University, South Korea
| | - Ranliang Hu
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta GA
| | - Kimberly B Hoang
- Department of Neurosurgery, Emory University School of Medicine, Atlanta GA
| | - Phillip Zhe Sun
- Emory National Primate Research Center, Emory University, Atlanta GA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta GA
| |
Collapse
|
17
|
Fillion AJ, Bricco AR, Lee HD, Korenchan D, Farrar CT, Gilad AA. Development of a synthetic biosensor for chemical exchange MRI utilizing in silico optimized peptides. NMR IN BIOMEDICINE 2023; 36:e5007. [PMID: 37469121 PMCID: PMC11075521 DOI: 10.1002/nbm.5007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 06/26/2023] [Accepted: 06/28/2023] [Indexed: 07/21/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI has been identified as a novel alternative to classical diagnostic imaging. Over the last several decades, many studies have been conducted to determine possible CEST agents, such as endogenously expressed compounds or proteins, that can be utilized to produce contrast with minimally invasive procedures and reduced or non-existent levels of toxicity. In recent years there has been an increased interest in the generation of genetically engineered CEST contrast agents, typically based on existing proteins with CEST contrast or modified to produce CEST contrast. We have developed an in silico method for the evolution of peptide sequences to optimize CEST contrast and showed that these peptides could be combined to create de novo biosensors for CEST MRI. A single protein, superCESTide, was designed to be 198 amino acids. SuperCESTide was expressed in E. coli and purified with size exclusion chromatography. The magnetic transfer ratio asymmetry generated by superCESTide was comparable to levels seen in previous CEST reporters, such as protamine sulfate (salmon protamine) and human protamine. These data show that novel peptides with sequences optimized in silico for CEST contrast that utilize a more comprehensive range of amino acids can still produce contrast when assembled into protein units expressed in complex living environments.
Collapse
Affiliation(s)
- Adam J. Fillion
- Department of Chemical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - Alexander R. Bricco
- Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - Harvey D. Lee
- Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - David Korenchan
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, MA, USA
| | - Christian T. Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, MA, USA
| | - Assaf A. Gilad
- Department of Chemical Engineering, Michigan State University, East Lansing, Michigan, USA
- Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| |
Collapse
|
18
|
Sun PZ. Numerical simulation-based assessment of pH-sensitive chemical exchange saturation transfer MRI quantification accuracy across field strengths. NMR IN BIOMEDICINE 2023; 36:e5000. [PMID: 37401645 DOI: 10.1002/nbm.5000] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 04/27/2023] [Accepted: 06/12/2023] [Indexed: 07/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI detects dilute labile protons via their exchange with bulk water, conferring pH sensitivity. Based on published exchange and relaxation properties, a 19-pool simulation was used to model the brain pH-dependent CEST effect and assess the accuracy of quantitative CEST (qCEST) analysis across magnetic field strengths under typical scan conditions. First, the optimal B1 amplitude was determined by maximizing pH-sensitive amide proton transfer (APT) contrast under the equilibrium condition. Apparent and quasi-steady-state (QUASS) CEST effects were then derived under the optimal B1 amplitude as functions of pH, RF saturation duration, relaxation delay, Ernst flip angle, and field strength. Finally, CEST effects, particularly the APT signal, were isolated with spinlock model-based Z-spectral fitting to evaluate the accuracy and consistency of CEST quantification. Our data showed that QUASS reconstruction significantly improved the consistency between simulated and equilibrium Z-spectra. The residual difference between QUASS and equilibrium CEST Z-spectra was, on average, 30 times less than that of the apparent CEST Z-spectra across field strengths, saturation, and repetition times. Also, the spinlock fitting of the QUASS CEST effect significantly reduced the residual errors 9-fold. Furthermore, the isolated APT amplitude from QUASS reconstruction was consistent and higher than the apparent CEST analysis under nonequilibrium conditions. To summarize, this study confirmed that QUASS reconstruction facilitates accurate determination of the CEST system under different scan protocols across field strengths, with the potential to help standardize CEST quantification.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
19
|
Chen H, Chen X, Lin L, Cai S, Cai C, Chen Z, Xu J, Chen L. Learned spatiotemporal correlation priors for CEST image denoising using incorporated global-spectral convolution neural network. Magn Reson Med 2023; 90:2071-2088. [PMID: 37332198 DOI: 10.1002/mrm.29763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 05/29/2023] [Accepted: 05/30/2023] [Indexed: 06/20/2023]
Abstract
PURPOSE To develop a deep learning-based method, dubbed Denoising CEST Network (DECENT), to fully exploit the spatiotemporal correlation prior to CEST image denoising. METHODS DECENT is composed of two parallel pathways with different convolution kernel sizes aiming to extract the global and spectral features embedded in CEST images. Each pathway consists of a modified U-Net with residual Encoder-Decoder network and 3D convolution. Fusion pathway with 1 × 1 × 1 convolution kernel is utilized to concatenate two parallel pathways, and the output of DECENT is noise-reduced CEST images. The performance of DECENT was validated in numerical simulations, egg white phantom experiments, and ischemic mouse brain and human skeletal muscle experiments in comparison with existing state-of-the-art denoising methods. RESULTS Rician noise was added to CEST images to mimic a low SNR situation for numerical simulation, egg white phantom experiment, and mouse brain experiments, while human skeletal muscle experiments were of inherently low SNR. From the denoising results evaluated by peak SNR (PSNR) and structural similarity index (SSIM), the proposed deep learning-based denoising method (DECENT) can achieve better performance compared to existing CEST denoising methods such as NLmCED, MLSVD, and BM4D, avoiding complicated parameter tuning or time-consuming iterative processes. CONCLUSIONS DECENT can well exploit the prior spatiotemporal correlation knowledge of CEST images and restore the noise-free images from their noisy observations, outperforming state-of-the-art denoising methods.
Collapse
Affiliation(s)
- Huan Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Xinran Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Liangjie Lin
- MSC Clinical & Technical Solutions, Philips Healthcare, Beijing, China
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Congbo Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Jiadi Xu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| |
Collapse
|
20
|
Nagar D, Vladimirov N, Farrar CT, Perlman O. Dynamic and rapid deep synthesis of chemical exchange saturation transfer and semisolid magnetization transfer MRI signals. Sci Rep 2023; 13:18291. [PMID: 37880343 PMCID: PMC10600114 DOI: 10.1038/s41598-023-45548-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023] Open
Abstract
Model-driven analysis of biophysical phenomena is gaining increased attention and utility for medical imaging applications. In magnetic resonance imaging (MRI), the availability of well-established models for describing the relations between the nuclear magnetization, tissue properties, and the externally applied magnetic fields has enabled the prediction of image contrast and served as a powerful tool for designing the imaging protocols that are now routinely used in the clinic. Recently, various advanced imaging techniques have relied on these models for image reconstruction, quantitative tissue parameter extraction, and automatic optimization of acquisition protocols. In molecular MRI, however, the increased complexity of the imaging scenario, where the signals from various chemical compounds and multiple proton pools must be accounted for, results in exceedingly long model simulation times, severely hindering the progress of this approach and its dissemination for various clinical applications. Here, we show that a deep-learning-based system can capture the nonlinear relations embedded in the molecular MRI Bloch-McConnell model, enabling a rapid and accurate generation of biologically realistic synthetic data. The applicability of this simulated data for in-silico, in-vitro, and in-vivo imaging applications is then demonstrated for chemical exchange saturation transfer (CEST) and semisolid macromolecule magnetization transfer (MT) analysis and quantification. The proposed approach yielded 63-99% acceleration in data synthesis time while retaining excellent agreement with the ground truth (Pearson's r > 0.99, p < 0.0001, normalized root mean square error < 3%).
Collapse
Affiliation(s)
- Dinor Nagar
- School of Electrical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Nikita Vladimirov
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel
| | - Christian T Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
| | - Or Perlman
- Department of Biomedical Engineering, Tel Aviv University, 6997801, Tel Aviv, Israel.
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
21
|
Tokunaga C, Wada T, Togao O, Yamashita Y, Kobayashi K, Kato T. Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study. Magn Reson Med Sci 2023; 22:487-495. [PMID: 36047248 PMCID: PMC10552662 DOI: 10.2463/mrms.mp.2021-0109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 07/16/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Amide proton transfer (APT) imaging may detect changes in tissues' pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. METHODS Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53-7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI each saturation pulse - APT SI shortest or weakest pulse)/APT SIshortest or weakest pulse. The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. RESULTS The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. CONCLUSION The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values.
Collapse
Affiliation(s)
- Chiaki Tokunaga
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan
| | - Osamu Togao
- Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Fukuoka, Japan
| | - Yasuo Yamashita
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan
| | - Kouji Kobayashi
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan
| | - Toyoyuki Kato
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Fukuoka, Japan
| |
Collapse
|
22
|
Huang Q, Wu J, Le N, Shen Y, Guo P, Schreck KC, Kamson D, Blair L, Heo HY, Li X, Li W, Sair HL, Blakeley JO, Laterra J, Holdhoff M, Grossman SA, Mukherjee D, Bettegowda C, van Zijl P, Zhou J, Jiang S. CEST2022: Amide proton transfer-weighted MRI improves the diagnostic performance of multiparametric non-contrast-enhanced MRI techniques in patients with post-treatment high-grade gliomas. Magn Reson Imaging 2023; 102:222-228. [PMID: 37321378 PMCID: PMC10528251 DOI: 10.1016/j.mri.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Accepted: 06/12/2023] [Indexed: 06/17/2023]
Abstract
New or enlarged lesions in malignant gliomas after surgery and chemoradiation can be associated with tumor recurrence or treatment effect. Due to similar radiographic characteristics, conventional-and even some advanced MRI techniques-are limited in distinguishing these two pathologies. Amide proton transfer-weighted (APTw) MRI, a protein-based molecular imaging technique that does not require the administration of any exogenous contrast agent, was recently introduced into the clinical setting. In this study, we evaluated and compared the diagnostic performances of APTw MRI with several non-contrast-enhanced MRI sequences, such as diffusion-weighted imaging, susceptibility-weighted imaging, and pseudo-continuous arterial spin labeling. Thirty-nine scans from 28 glioma patients were obtained on a 3 T MRI scanner. A histogram analysis approach was employed to extract parameters from each tumor area. Statistically significant parameters (P < 0.05) were selected to train multivariate logistic regression models to evaluate the performance of MRI sequences. Multiple histogram parameters, particularly from APTw and pseudo-continuous arterial spin labeling images, demonstrated significant differences between treatment effect and recurrent tumor. The regression model trained on the combination of all significant histogram parameters achieved the best result (area under the curve = 0.89). We found that APTw images added value to other advanced MR images for the differentiation of treatment effect and tumor recurrence.
Collapse
Affiliation(s)
- Qianqi Huang
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Biomedical Engineering, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Jingpu Wu
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Applied Mathematics and Statistics, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Nhat Le
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Computer Science, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Yiqing Shen
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Computer Science, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Pengfei Guo
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Computer Science, Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Karisa C Schreck
- Department of Neurology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - David Kamson
- Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Lindsay Blair
- Department of Neurology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Hye-Young Heo
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Xu Li
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Wenbo Li
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Haris L Sair
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Malone Center for Engineering in Healthcare, The Whiting School of Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Jaishri O Blakeley
- Department of Neurology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - John Laterra
- Department of Neurology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Matthias Holdhoff
- Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Stuart A Grossman
- Department of Oncology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Debraj Mukherjee
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Chetan Bettegowda
- Department of Neurosurgery, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Peter van Zijl
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Jinyuan Zhou
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Shanshan Jiang
- Department of Radiology, School of Medicine, Johns Hopkins University, Baltimore, MD, USA.
| |
Collapse
|
23
|
Cui J, Zhao Y, Sun C, Xu J, Zu Z. Evaluation of contributors to amide proton transfer-weighted imaging and nuclear Overhauser enhancement-weighted imaging contrast in tumors at a high magnetic field. Magn Reson Med 2023; 90:596-614. [PMID: 37093984 PMCID: PMC10616782 DOI: 10.1002/mrm.29675] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 03/31/2023] [Accepted: 03/31/2023] [Indexed: 04/26/2023]
Abstract
PURPOSE The purpose is to evaluate the relative contribution from confounding factors (T1 weighting and magnetization transfer) to the CEST ratio (CESTR)-quantified amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) (-3.5) in tumors as well as whether the CESTR can reflect the distribution of the solute concentration (fs ). METHODS We first provided a signal model that shows the separate dependence of CESTR on these confounding factors and the clean CEST/NOE effects quantified by an apparent exchange-dependent relaxation (AREX) method. We then measured the change in these effects in the 9-L tumor model in rats, through which we calculated the relative contribution of each confounding factor. fs was also fitted, and its correlations with the CESTR and AREX were assessed to evaluate their capabilities to reflect fs . RESULTS The CESTR-quantified APT shows "positive" contrast in tumors, which arises primarily from R1w at low powers and both R1w and magnetization transfer at high powers. CESTR-quantified NOE (-3.5) shows no or weak contrast in tumors, which is due to the cancelation of R1w and NOE (-3.5), which have opposite contributions. CESTR-quantified APT has a stronger correlation with APT fs than AREX-quantified APT. CESTR-quantified NOE (-3.5) has a weaker correlation with NOE (-3.5) fs than AREX-quantified NOE (-3.5). CONCLUSION CESTR reflects a combined effect of T1 weighting and CEST/NOE. Both factors depend on fs , which contributes positively to the dependence of CESTR on fs in APT imaging and enhances its correlation with fs . In contrast, these factors have opposite contributions to its dependence on fs in NOE (-3.5) imaging, thereby weakening the correlation.
Collapse
Affiliation(s)
- Jing Cui
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Yu Zhao
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Casey Sun
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Chemistry, University of Florida, Gainesville, US
| | - Junzhong Xu
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Biomedical Engineering, Vanderbilt University, Nashville, US
- Department of Physics and Astronomy, Vanderbilt University, Nashville, US
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Biomedical Engineering, Vanderbilt University, Nashville, US
| |
Collapse
|
24
|
Zhao Y, Sun C, Zu Z. Assignment of molecular origins of NOE signal at -3.5 ppm in the brain. Magn Reson Med 2023; 90:673-685. [PMID: 36929814 PMCID: PMC10644915 DOI: 10.1002/mrm.29643] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Revised: 02/15/2023] [Accepted: 03/06/2023] [Indexed: 03/18/2023]
Abstract
PURPOSE Nuclear Overhauser enhancemen mediated saturation transfer effect, termed NOE (-3.5 ppm), is a major source of CEST MRI contrasts at 3.5 ppm in the brain. Previous phantom experiments have demonstrated that both proteins and lipids, two major components in tissues, have substantial contributions to NOE (-3.5 ppm) signals. Their relative contributions in tissues are informative for the interpretation of NOE (-3.5 ppm) contrasts that could provide potential imaging biomarkers for relevant diseases, which remain incompletely understood. METHODS Experiments on homogenates and supernatants of brain tissues collected from healthy rats, that could isolate proteins from lipids, were performed to evaluate the relative contribution of lipids to NOE (-3.5 ppm) signals. On the other hand, experiments on ghost membranes with varied pH, and reconstituted phospholipids with different chemical compositions were conducted to study the dependence of NOE (-3.5 ppm) on physiological conditions. Besides, CEST imaging on rat brains bearing 9 L tumors and healthy rat brains was performed to analyze the causes of the NOE (-3.5 ppm) contrast variations between tumors and normal tissues, and between gray matter and white matter. RESULTS Our experiments reveal that lipids have dominant contributions to the NOE (-3.5 ppm) signals. Further analysis suggests that decreased NOE (-3.5 ppm) signals in tumors and higher NOE (-3.5 ppm) signals in white matter than in gray matter are mainly explained by changes in membrane lipids, rather than proteins. CONCLUSION NOE (-3.5 ppm) could be exploited as a highly sensitive MRI contrast for imaging membrane lipids in the brain.
Collapse
Affiliation(s)
- Yu Zhao
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Department of Radiology, West China Hospital of Sichuan University, Chengdu, China
| | - Casey Sun
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Chemistry, University of Florida, Gainesville, US
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| |
Collapse
|
25
|
Huang S, Deng H, Wei X, Zhang J. Progress in application of terahertz time-domain spectroscopy for pharmaceutical analyses. Front Bioeng Biotechnol 2023; 11:1219042. [PMID: 37533693 PMCID: PMC10393043 DOI: 10.3389/fbioe.2023.1219042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 06/12/2023] [Indexed: 08/04/2023] Open
Abstract
Terahertz time-domain spectroscopy is an analytical method using terahertz time-domain pulses to study the physical and chemical properties of substances. It has strong potential for application in pharmaceutical analyses as an original non-destructive, efficient and convenient technology for spectral detection. This review briefly introduces the working principle of terahertz time-domain spectroscopy technology, focuses on the research achievements of this technology in analyses of chemical drugs, traditional Chinese medicine and biological drugs in the past decade. We also reveal the scientific feasibility of practical application of terahertz time-domain spectroscopy for pharmaceutical detection. Finally, we discuss the problems in practical application of terahertz time-domain spectroscopy technology, and the prospect of further development of this technology in pharmaceutical analyses. We hope that this review can provide a reference for application of terahertz time-domain spectroscopy technology in pharmaceutical analyses in the future.
Collapse
Affiliation(s)
- Shuteng Huang
- School of Pharmacy, Binzhou Medical University, Yantai, China
| | - Hanxiu Deng
- School of Pharmacy, Binzhou Medical University, Yantai, China
| | - Xia Wei
- Shandong Institute for Food and Drug Control, Jinan, China
| | - Jiayu Zhang
- School of Pharmacy, Binzhou Medical University, Yantai, China
| |
Collapse
|
26
|
Kim H, Kim J, Sun PZ. CEST2022 - mapping multi-pool CEST signal changes in an animal model of brain tumor with quasi-steady-state reconstruction-empowered CEST quantification. Magn Reson Imaging 2023:S0730-725X(23)00100-5. [PMID: 37321379 DOI: 10.1016/j.mri.2023.06.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Accepted: 06/12/2023] [Indexed: 06/17/2023]
Abstract
Chemical exchange saturated transfer (CEST) MRI has biomarker potential to assess tissue microenvironment in brain tumors. Multi-pool Lorentzian or spinlock models provides useful insights into the CEST contrast mechanism. However, T1 contribution to the complex overlapping effects of brain tumors is difficult under the non-equilibrium state. Therefore, this study evaluated T1 contributions on multi-pool parameters with quasi-steady-state (QUASS) algorithm reconstructed equilibrium data. MRI scans were performed in rat brain tumor models, including relaxation, diffusion, and CEST imaging. A pixel-wise seven-pool spinlock-model was employed to fit QUASS reconstructed CEST Z-spectra and evaluated the magnetization transfer (MT), amide, amine, guanidyl, and nuclear-overhauled effect (NOE) signals in tumor and normal tissues. In addition, T1 was estimated from the spinlock-model fitting and compared with measured T1. We observed tumor had a statistically significant increase in the amide signal (p < 0.001) and decreases in the MT and NOE signals (p < 0.001). On the other hand, the differences in amine and guanidyl between the tumor and contralateral normal regions were not statistically significant. The differences between measured and estimated T1 values were 8% in the normal tissue and 4% in the tumor. Furthermore, the isolated MT signal strongly correlated with R1 (r = 0.96, P < 0.001). In summary, we successfully unraveled multi-factorial effects in the CEST signal using spinlock-model fitting and QUASS method and demonstrated the effect of T1 relaxation on MT and NOE.
Collapse
Affiliation(s)
- Hahnsung Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| | - Jinsuh Kim
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America
| | - Phillip Zhe Sun
- Emory National Primate Research Center, Emory University, Atlanta, GA, United States of America; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States of America.
| |
Collapse
|
27
|
Vinogradov E, Keupp J, Dimitrov IE, Seiler S, Pedrosa I. CEST-MRI for body oncologic imaging: are we there yet? NMR IN BIOMEDICINE 2023; 36:e4906. [PMID: 36640112 PMCID: PMC10200773 DOI: 10.1002/nbm.4906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 05/23/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI has gained recognition as a valuable addition to the molecular imaging and quantitative biomarker arsenal, especially for characterization of brain tumors. There is also increasing interest in the use of CEST-MRI for applications beyond the brain. However, its translation to body oncology applications lags behind those in neuro-oncology. The slower migration of CEST-MRI to non-neurologic applications reflects the technical challenges inherent to imaging of the torso. In this review, we discuss the application of CEST-MRI to oncologic conditions of the breast and torso (i.e., body imaging), emphasizing the challenges and potential solutions to address them. While data are still limited, reported studies suggest that CEST signal is associated with important histology markers such as tumor grade, receptor status, and proliferation index, some of which are often associated with prognosis and response to therapy. However, further technical development is still needed to make CEST a reliable clinical application for body imaging and establish its role as a predictive and prognostic biomarker.
Collapse
Affiliation(s)
- Elena Vinogradov
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | | | - Ivan E Dimitrov
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
- Philips Healthcare, Gainesville, FL, USA
| | - Stephen Seiler
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Ivan Pedrosa
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
28
|
Xu J, Chung JJ, Jin T. Chemical exchange saturation transfer imaging of creatine, phosphocreatine, and protein arginine residue in tissues. NMR IN BIOMEDICINE 2023; 36:e4671. [PMID: 34978371 PMCID: PMC9250548 DOI: 10.1002/nbm.4671] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/06/2021] [Accepted: 12/02/2021] [Indexed: 05/05/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI has become a promising technique to assay target proteins and metabolites through their exchangeable protons, noninvasively. The ubiquity of creatine (Cr) and phosphocreatine (PCr) due to their pivotal roles in energy homeostasis through the creatine phosphate pathway has made them prime targets for CEST in the diagnosis and monitoring of disease pathologies, particularly in tissues heavily dependent on the maintenance of rich energy reserves. Guanidinium CEST from protein arginine residues (i.e. arginine CEST) can also provide information about the protein profile in tissue. However, numerous obfuscating factors stand as obstacles to the specificity of arginine, Cr, and PCr imaging through CEST, such as semisolid magnetization transfer, fast chemical exchanges such as primary amines, and the effects of nuclear Overhauser enhancement from aromatic and amide protons. In this review, the specific exchange properties of protein arginine residues, Cr, and PCr, along with their validation, are discussed, including the considerations necessary to target and tune their signal effects through CEST imaging. Additionally, strategies that have been employed to enhance the specificity of these exchanges in CEST imaging are described, along with how they have opened up possible applications of protein arginine residues, Cr and PCr CEST imaging in the study and diagnosis of pathology. A clear understanding of the capabilities and caveats of using CEST to image these vital metabolites and mitigation strategies is crucial to expanding the possibilities of this promising technology.
Collapse
Affiliation(s)
- Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Julius Juhyun Chung
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
29
|
Zhou Y, Bie C, van Zijl PC, Yadav NN. The relayed nuclear Overhauser effect in magnetization transfer and chemical exchange saturation transfer MRI. NMR IN BIOMEDICINE 2023; 36:e4778. [PMID: 35642102 PMCID: PMC9708952 DOI: 10.1002/nbm.4778] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 05/19/2022] [Accepted: 05/29/2022] [Indexed: 05/23/2023]
Abstract
Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low-concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon-bound protons in mobile macromolecules in solution. In this review, we describe the mechanisms leading to the occurrence of rNOE-based signals in the water saturation spectrum (Z-spectrum), including those from mobile and immobile molecular sources and from molecular binding. While it is becoming clear that MTC is mainly an rNOE-based signal, we continue to use the classical MTC nomenclature to separate it from the rNOE signals of mobile macromolecules, which we will refer to as rNOEs. Some emerging applications of the use of rNOEs for probing macromolecular solution components such as proteins and carbohydrates in vivo or studying the binding of small substrates are discussed.
Collapse
Affiliation(s)
- Yang Zhou
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen University Town, Shenzhen, Guangdong 518055 (China)
| | - Chongxue Bie
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
- Department of Information Science and Technology, Northwest University, No.1 Xuefu Avenue, Xi’an, Shanxi 710127 (China)
| | - Peter C.M. van Zijl
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| | - Nirbhay N. Yadav
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| |
Collapse
|
30
|
Benyard B, Nanga RPR, Wilson NE, Thakuri D, Jacobs PS, Swain A, Kumar D, Reddy R. In vivo reproducibility of 3D relayed NOE in the healthy human brain at 7 T. Magn Reson Med 2023; 89:2295-2304. [PMID: 36744726 PMCID: PMC10078808 DOI: 10.1002/mrm.29600] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 01/09/2023] [Accepted: 01/11/2023] [Indexed: 02/07/2023]
Abstract
PURPOSE Nuclear Overhauser effect (NOE) is based on dipolar cross-relaxation mechanism that enables the indirect detection of aliphatic protons via the water proton signal. This work focuses on determining the reproducibility of NOE magnetization transfer ratio (NOEMTR ) and isolated or relayed NOE (rNOE) contributions to the NOE MRI of the healthy human brain at 7 Tesla (T). METHODS We optimized theB 1 + $$ {\mathrm{B}}_1^{+} $$ amplitude and length of the saturation pulse by acquiring NOE images with differentB 1 + $$ {\mathrm{B}}_1^{+} $$ values with multiple saturation lengths. Repeated NOE MRI measurements were made on five healthy volunteers by using optimized saturation pulse parameters including correction of B0 andB 1 + $$ {\mathrm{B}}_1^{+} $$ inhomogeneities. To isolate the individual contributions from z-spectra, we have fit the NOE z-spectra using multiple Lorentzians and calculated the total contribution from each pool contributing to the overall NOEMTR contrast. RESULTS We found that a saturation amplitude of 0.72 μT and a length of 3 s provided the highest contrast. We found that the mean NOEMTR value in gray matter (GM) was 26%, and in white matter (WM) was 33.3% across the 3D slab of the brain. The mean rNOE contributions from GM and WM values were 8.9% and 9.6%, which were ∼10% of the corresponding total NOEMTR signal. The intersubject coefficient of variations (CoVs) of NOEMTR from GM and WM were 4.5% and 6.5%, respectively, whereas the CoVs of rNOE were 4.8% and 5.6%, respectively. The intrasubject CoVs of the NOEMTR range was 2.1%-4.2%, and rNOE range was 2.9%-10.5%. CONCLUSION This work has demonstrated an excellent reproducibility of both inter- and intrasubject NOEMTR and rNOE metrics in healthy human brains at 7 T.
Collapse
Affiliation(s)
- Blake Benyard
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravi Prakash Reddy Nanga
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Neil E. Wilson
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Deepa Thakuri
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Paul S. Jacobs
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Anshuman Swain
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Dushyant Kumar
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Ravinder Reddy
- Center for Metabolic Imaging in Precision Medicine (CAMIPM), Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
31
|
Bie C, van Zijl P, Xu J, Song X, Yadav NN. Radiofrequency labeling strategies in chemical exchange saturation transfer MRI. NMR IN BIOMEDICINE 2023; 36:e4944. [PMID: 37002814 PMCID: PMC10312378 DOI: 10.1002/nbm.4944] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 03/19/2023] [Accepted: 03/27/2023] [Indexed: 05/23/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI has generated great interest for molecular imaging applications because it can image low-concentration solute molecules in vivo with enhanced sensitivity. CEST effects are detected indirectly through a reduction in the bulk water signal after repeated perturbation of the solute proton magnetization using one or more radiofrequency (RF) irradiation pulses. The parameters used for these RF pulses-frequency offset, duration, shape, strength, phase, and interpulse spacing-determine molecular specificity and detection sensitivity, thus their judicious selection is critical for successful CEST MRI scans. This review article describes the effects of applying RF pulses on spin systems and compares conventional saturation-based RF labeling with more recent excitation-based approaches that provide spectral editing capabilities for selectively detecting molecules of interest and obtaining maximal contrast.
Collapse
Affiliation(s)
- Chongxue Bie
- Department of Information Science and Technology, Northwest University, No.1 Xuefu Avenue, Xi’an, Shaanxi 710127 (China)
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| | - Peter van Zijl
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| | - Xiaolei Song
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Haidian District, Beijing 100084 (China)
| | - Nirbhay N. Yadav
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, 707 N. Broadway, Baltimore MD 21205 (USA)
- The Russell H. Morgan Department of Radiology, The Johns Hopkins University School of Medicine, 720 Rutland Ave, Baltimore, MD 21205 (USA)
| |
Collapse
|
32
|
Sun PZ. Generalization of quasi-steady-state reconstruction to CEST MRI with two-tiered RF saturation and gradient-echo readout-Synergistic nuclear Overhauser enhancement contribution to brain tumor amide proton transfer-weighted MRI. Magn Reson Med 2023; 89:2014-2023. [PMID: 36579767 DOI: 10.1002/mrm.29570] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 12/30/2022]
Abstract
PURPOSE While amide proton transfer-weighted (APTw) MRI has been adopted in tumor imaging, there are concurrent APT, magnetization transfer, and nuclear Overhauser enhancement changes. Also, the APTw image is confounded by relaxation changes, particularly when the relaxation delay and saturation time are not sufficiently long. Our study aimed to extend a quasi-steady-state (QUASS) solution to determine the contribution of the multipool CEST signals to the observed tumor APTw contrast. METHODS Our study derived the QUASS solution for a multislice CEST-MRI sequence with an interleaved RF saturation and gradient-echo readout between signal averaging. Multiparametric MRI scans were obtained in rat brain tumor models, including T1 , T2 , diffusion, and CEST scans. Finally, we performed spinlock model-based multipool fitting to determine multiple concurrent CEST signal changes in the tumor. RESULTS The QUASS APTw MRI showed small but significant differences in normal and tumor tissues and their contrast from the acquired asymmetry calculation. The spinlock model-based fitting showed significant differences in semisolid magnetization transfer, amide, and nuclear Overhauser enhancement effects between the apparent and QUASS CEST MRI. In addition, we determined that the tumor APTw contrast is due to synergistic APT increase (+3.5 ppm) and NOE decrease (-3.5 ppm), with their relative contribution being about one third and two thirds under a moderate B1 of 0.75 μT at 4.7 T. CONCLUSION Our study generalized QUASS analysis to gradient-echo image readout and quantified the underlying tumor CEST signal changes, providing an improved elucidation of the commonly used APTw MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Emory Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, Georgia, USA.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
33
|
Weigand-Whittier J, Sedykh M, Herz K, Coll-Font J, Foster AN, Gerstner ER, Nguyen C, Zaiss M, Farrar CT, Perlman O. Accelerated and quantitative three-dimensional molecular MRI using a generative adversarial network. Magn Reson Med 2023; 89:1901-1914. [PMID: 36585915 PMCID: PMC9992146 DOI: 10.1002/mrm.29574] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 12/13/2022] [Accepted: 12/15/2022] [Indexed: 01/01/2023]
Abstract
PURPOSE To substantially shorten the acquisition time required for quantitative three-dimensional (3D) chemical exchange saturation transfer (CEST) and semisolid magnetization transfer (MT) imaging and allow for rapid chemical exchange parameter map reconstruction. METHODS Three-dimensional CEST and MT magnetic resonance fingerprinting (MRF) datasets of L-arginine phantoms, whole-brains, and calf muscles from healthy volunteers, cancer patients, and cardiac patients were acquired using 3T clinical scanners at three different sites, using three different scanner models and coils. A saturation transfer-oriented generative adversarial network (GAN-ST) supervised framework was then designed and trained to learn the mapping from a reduced input data space to the quantitative exchange parameter space, while preserving perceptual and quantitative content. RESULTS The GAN-ST 3D acquisition time was 42-52 s, 70% shorter than CEST-MRF. The quantitative reconstruction of the entire brain took 0.8 s. An excellent agreement was observed between the ground truth and GAN-based L-arginine concentration and pH values (Pearson's r > 0.95, ICC > 0.88, NRMSE < 3%). GAN-ST images from a brain-tumor subject yielded a semi-solid volume fraction and exchange rate NRMSE of3 . 8 ± 1 . 3 % $$ 3.8\pm 1.3\% $$ and4 . 6 ± 1 . 3 % $$ 4.6\pm 1.3\% $$ , respectively, and SSIM of96 . 3 ± 1 . 6 % $$ 96.3\pm 1.6\% $$ and95 . 0 ± 2 . 4 % $$ 95.0\pm 2.4\% $$ , respectively. The mapping of the calf-muscle exchange parameters in a cardiac patient, yielded NRMSE < 7% and SSIM > 94% for the semi-solid exchange parameters. In regions with large susceptibility artifacts, GAN-ST has demonstrated improved performance and reduced noise compared to MRF. CONCLUSION GAN-ST can substantially reduce the acquisition time for quantitative semi-solid MT/CEST mapping, while retaining performance even when facing pathologies and scanner models that were not available during training.
Collapse
Affiliation(s)
- Jonah Weigand-Whittier
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
| | - Maria Sedykh
- Institute of Neuroradiology, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Kai Herz
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department of Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
| | - Jaume Coll-Font
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
- Cardiovascular Research Center, Cardiology Division, Massachusetts General Hospital, Charlestown, Massachusetts
| | - Anna N. Foster
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
- Cardiovascular Research Center, Cardiology Division, Massachusetts General Hospital, Charlestown, Massachusetts
| | - Elizabeth R. Gerstner
- Massachusetts General Hospital Cancer Center, Harvard Medical School, Boston, Massachusetts
| | - Christopher Nguyen
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
- Cardiovascular Research Center, Cardiology Division, Massachusetts General Hospital, Charlestown, Massachusetts
- Health Science Technology, Harvard-MIT, Cambridge, Massachusetts
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Moritz Zaiss
- Institute of Neuroradiology, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
- Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Christian T. Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
| | - Or Perlman
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
- Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
34
|
Yong X, Lu S, Hsu YC, Fu C, Sun Y, Zhang Y. Numerical fitting of Extrapolated semisolid Magnetization transfer Reference signals: Improved detection of ischemic stroke. Magn Reson Med 2023; 90:722-736. [PMID: 37052377 DOI: 10.1002/mrm.29660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/09/2023] [Accepted: 03/18/2023] [Indexed: 04/14/2023]
Abstract
PURPOSE To propose a novel Numerical fitting method of the Extrapolated semisolid Magnetization transfer Reference (NEMR) signal for quantifying the CEST effect. THEORY AND METHODS Modified two-pool Bloch-McConnell equations were used to numerically fit the magnetization transfer (MT) and direct water saturation (DS) signals at far off-resonance frequencies, which was subsequently extrapolated into the frequency range of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) pools. Then the subtraction of the fitted two-pool z-spectrum and the experimentally acquired z-spectrum yielded APT# and NOE# signals mostly free of MT and DS contamination. Several strategies were used to accelerate the NEMR fitting. Furthermore, the proposed NEMR method was compared with the conventional extrapolated semisolid magnetization transfer reference (EMR) and magnetization transfer ratio asymmetry (MTRasym ) methods in simulations and stroke patients. RESULTS The combination of RF downsampling, MT lineshape look-up table, and conversion of MATLAB code to C code accelerated the NEMR fitting by over 2700-fold. Monte-Carlo simulations showed that NEMR had higher accuracy than EMR and eliminated the requirement of the steady-state condition. In ischemic stroke patients, the NEMR maps at 1 μT removed hypointense artifacts seen on EMR and MTRasym images, and better depicted stroke lesions than EMR. For NEMR, NOE# yielded significantly (p < 0.05) stronger signal contrast between stroke and normal tissues than APT# at 1 μT. CONCLUSION The proposed NEMR method is suitable for arbitrary saturation settings and can remove MT and DS contamination from the CEST signal for improved detection of ischemic stroke.
Collapse
Affiliation(s)
- Xingwang Yong
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Shanshan Lu
- The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China
| | - Yi-Cheng Hsu
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Caixia Fu
- Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, Guangdong, China
| | - Yi Sun
- MR Collaboration, Siemens Healthcare Ltd., Shanghai, China
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| |
Collapse
|
35
|
Wamelink IJHG, Hempel HL, van de Giessen E, Vries MHM, De Witt Hamer P, Barkhof F, Keil VC. The patients' experience of neuroimaging of primary brain tumors: a cross-sectional survey study. J Neurooncol 2023; 162:307-315. [PMID: 36977844 PMCID: PMC10167184 DOI: 10.1007/s11060-023-04290-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Accepted: 03/04/2023] [Indexed: 03/30/2023]
Abstract
PURPOSE To gain insight into how patients with primary brain tumors experience MRI, follow-up protocols, and gadolinium-based contrast agent (GBCA) use. METHODS Primary brain tumor patients answered a survey after their MRI exam. Questions were analyzed to determine trends in patients' experience regarding the scan itself, follow-up frequency, and the use of GBCAs. Subgroup analysis was performed on sex, lesion grade, age, and the number of scans. Subgroup comparison was made using the Pearson chi-square test and the Mann-Whitney U-test for categorical and ordinal questions, respectively. RESULTS Of the 100 patients, 93 had a histopathologically confirmed diagnosis, and seven were considered to have a slow-growing low-grade tumor after multidisciplinary assessment and follow-up. 61/100 patients were male, with a mean age ± standard deviation of 44 ± 14 years and 46 ± 13 years for the females. Fifty-nine patients had low-grade tumors. Patients consistently underestimated the number of their previous scans. 92% of primary brain tumor patients did not experience the MRI as bothering and 78% would not change the number of follow-up MRIs. 63% of the patients would prefer GBCA-free MRI scans if diagnostically equally accurate. Women found the MRI and receiving intravenous cannulas significantly more uncomfortable than men (p = 0.003). Age, diagnosis, and the number of previous scans had no relevant impact on the patient experience. CONCLUSION Patients with primary brain tumors experienced current neuro-oncological MRI practice as positive. Especially women would, however, prefer GBCA-free imaging if diagnostically equally accurate. Patient knowledge of GBCAs was limited, indicating improvable patient information.
Collapse
Affiliation(s)
- Ivar J H G Wamelink
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands.
- Cancer Center Amsterdam, Brain Tumor Center Amsterdam, Amsterdam, The Netherlands.
| | - Hugo L Hempel
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Elsmarieke van de Giessen
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, De Boelelaan 1117, Amsterdam, The Netherlands
| | - Mark H M Vries
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
| | - Philip De Witt Hamer
- Cancer Center Amsterdam, Brain Tumor Center Amsterdam, Amsterdam, The Netherlands
- Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, The Netherlands
| | - Frederik Barkhof
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- Queen Square Institute of Neurology and Centre for Medical Image Computing, University College London, London, UK
| | - Vera C Keil
- Radiology & Nuclear Medicine Department, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Brain Tumor Center Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, De Boelelaan 1117, Amsterdam, The Netherlands
| |
Collapse
|
36
|
Fillion AJ, Bricco AR, Lee HD, Korenchan D, Farrar CT, Gilad AA. Development of a Synthetic Biosensor for Chemical Exchange MRI Utilizing In Silico Optimized Peptides. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.03.08.531737. [PMID: 37016672 PMCID: PMC10071792 DOI: 10.1101/2023.03.08.531737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Chemical Exchange Saturation Transfer (CEST) magnetic resonance imaging (MRI) has been identified as a novel alternative to classical diagnostic imaging. Over the last several decades, many studies have been conducted to determine possible CEST agents, such as endogenously expressed compounds or proteins, that can be utilized to produce contrast with minimally invasive procedures and reduced or non-existent levels of toxicity. In recent years there has been an increased interest in the generation of genetically engineered CEST contrast agents, typically based on existing proteins with CEST contrast or modified to produce CEST contrast. We have developed an in-silico method for the evolution of peptide sequences to optimize CEST contrast and showed that these peptides could be combined to create de novo biosensors for CEST MRI. A single protein, superCESTide 2.0, was designed to be 198 amino acids. SuperCESTide 2.0 was expressed in E. coli and purified with size-exclusion chromatography. The magnetic transfer ratio asymmetry (MTR asym ) generated by superCESTide 2.0 was comparable to levels seen in previous CEST reporters, such as protamine sulfate (salmon protamine, SP), Poly-L-Lysine (PLL), and human protamine (hPRM1). This data shows that novel peptides with sequences optimized in silico for CEST contrast that utilizes a more comprehensive range of amino acids can still produce contrast when assembled into protein units expressed in complex living environments.
Collapse
Affiliation(s)
- Adam J. Fillion
- Department of Chemical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - Alexander R. Bricco
- Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - Harvey D. Lee
- Department of Biomedical Engineering, Michigan State University, East Lansing, Michigan, USA
| | - David Korenchan
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, MA, USA
| | - Christian T. Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, MA, USA
| | - Assaf A. Gilad
- Department of Chemical Engineering, Michigan State University, East Lansing, Michigan, USA
- Department of Radiology, Michigan State University, East Lansing, Michigan, USA
| |
Collapse
|
37
|
Sun PZ. Demonstration of accurate multi-pool chemical exchange saturation transfer MRI quantification - Quasi-steady-state reconstruction empowered quantitative CEST analysis. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 348:107379. [PMID: 36689786 PMCID: PMC10023465 DOI: 10.1016/j.jmr.2023.107379] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/05/2023] [Accepted: 01/15/2023] [Indexed: 05/18/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute labile protons and microenvironment properties, yet CEST quantification has been challenging. This difficulty is because the CEST measurement depends not only on the underlying CEST system but also on the scan protocols, including RF saturation amplitude, duration, and repetition time. In addition, T1 normalization is not straightforward under non-equilibrium conditions. Recently, a quasi-steady-state (QUASS) algorithm was established to reconstruct the desired equilibrium state from experimental measurements. Our study aimed to determine the accuracy of spinlock-model-based multi-pool CEST quantification using numerical simulations and phantom experiments. In short, CEST Z-spectra were simulated for a representative 3-pool model, and CEST amplitudes were solved with spinlock model-based multi-pool fitting and assessed as a function of RF saturation time (Ts), repetition time (TR), and T1. Although the apparent CEST signals showed significant T1 dependence, such relationships were not observed following QUASS reconstruction. To test the accuracy of T1 correction, a multi-vial phantom of nicotinamide and creatine was doped with manganese chloride, resulting in T1 ranging from 1 s to beyond 2 s. The multi-labile signals determined from the routine measurements showed significant dependence on Ts, TR, and T1. In contrast, CEST signals from the QUASS reconstruction showed consistent quantification independent of such variables. To summarize, our study demonstrated that accurate CEST quantification is feasible in multi-pool CEST systems with the spinlock-model-based fitting of QUASS CEST MRI.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Primate Imaging Center, Emory National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, United States.
| |
Collapse
|
38
|
Amide Proton Transfer-Chemical Exchange Saturation Transfer Imaging of Intracranial Brain Tumors and Tumor-like Lesions: Our Experience and a Review. Diagnostics (Basel) 2023; 13:diagnostics13050914. [PMID: 36900058 PMCID: PMC10000843 DOI: 10.3390/diagnostics13050914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 02/23/2023] [Accepted: 02/27/2023] [Indexed: 03/05/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) is a molecular magnetic resonance imaging (MRI) method that can generate image contrast based on the proton exchange between labeled protons in solutes and free, bulk water protons. Amide proton transfer (APT) imaging is the most frequently reported amide-proton-based CEST technique. It generates image contrast by reflecting the associations of mobile proteins and peptides resonating at 3.5 ppm downfield from water. Although the origin of the APT signal intensity in tumors is unclear, previous studies have suggested that the APT signal intensity is increased in brain tumors due to the increased mobile protein concentrations in malignant cells in association with an increased cellularity. High-grade tumors, which demonstrate a higher proliferation than low-grade tumors, have higher densities and numbers of cells (and higher concentrations of intracellular proteins and peptides) than low-grade tumors. APT-CEST imaging studies suggest that the APT-CEST signal intensity can be used to help differentiate between benign and malignant tumors and high-grade gliomas and low-grade gliomas as well as estimate the nature of lesions. In this review, we summarize the current applications and findings of the APT-CEST imaging of various brain tumors and tumor-like lesions. We report that APT-CEST imaging can provide additional information on intracranial brain tumors and tumor-like lesions compared to the information provided by conventional MRI methods, and that it can help indicate the nature of lesions, differentiate between benign and malignant lesions, and determine therapeutic effects. Future research could initiate or improve the lesion-specific clinical applicability of APT-CEST imaging for meningioma embolization, lipoma, leukoencephalopathy, tuberous sclerosis complex, progressive multifocal leukoencephalopathy, and hippocampal sclerosis.
Collapse
|
39
|
Three-Dimensional Gradient-Echo-Based Amide Proton Transfer-Weighted Imaging of Brain Tumors: Comparison With Two-Dimensional Spin-Echo-Based Amide Proton Transfer-Weighted Imaging. J Comput Assist Tomogr 2023; 47:00004728-990000000-00139. [PMID: 36790914 DOI: 10.1097/rct.0000000000001432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
OBJECTIVE Although amide proton transfer-weighted (APTw) imaging is reported by 2-dimensional (2D) spin-echo-based sequencing, 3-dimensional (3D) APTw imaging can be obtained by gradient-echo-based sequencing. The purpose of this study was to compare the efficacy of APTw imaging between 2D and 3D imaging in patients with various brain tumors. METHODS A total of 49 patients who had undergone 53 examinations [5 low-grade gliomas (LGG), 16 high-grade gliomas (HGG), 6 malignant lymphomas, 4 metastases, and 22 meningiomas] underwent APTw imaging using 2D and 3D sequences. The magnetization transfer ratio asymmetry (MTRasym) was assessed by means of region of interest measurements. Pearson correlation was performed to determine the relationship between MTRasym for the 2 methods, and Student's t test to compare MTRasym for LGG and HGG. The diagnostic accuracy to differentiate HGG from LGG of the 2 methods was compared by means of the McNemar test. RESULTS Three-dimensional APTw imaging showed a significant correlation with 2D APTw imaging (r = 0.79, P < 0.0001). The limits of agreement between the 2 methods were -0.021 ± 1.42%. The MTRasym of HGG (2D: 1.97 ± 0.96, 3D: 2.11 ± 0.95) was significantly higher than those of LGG (2D: 0.46 ± 0.89%, P < 0.01; 3D: 0.15 ± 1.09%, P < 0.001). The diagnostic performance of the 2 methods to differentiate HGG from LGG was not significantly different (P = 1). CONCLUSIONS The potential capability of 3D APTw imaging is equal to or greater than that of 2D APTw imaging and is considered at least as valuable in patients with brain tumors.
Collapse
|
40
|
Molecular MRI-Based Monitoring of Cancer Immunotherapy Treatment Response. Int J Mol Sci 2023; 24:ijms24043151. [PMID: 36834563 PMCID: PMC9959624 DOI: 10.3390/ijms24043151] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Revised: 01/29/2023] [Accepted: 02/02/2023] [Indexed: 02/09/2023] Open
Abstract
Immunotherapy constitutes a paradigm shift in cancer treatment. Its FDA approval for several indications has yielded improved prognosis for cases where traditional therapy has shown limited efficiency. However, many patients still fail to benefit from this treatment modality, and the exact mechanisms responsible for tumor response are unknown. Noninvasive treatment monitoring is crucial for longitudinal tumor characterization and the early detection of non-responders. While various medical imaging techniques can provide a morphological picture of the lesion and its surrounding tissue, a molecular-oriented imaging approach holds the key to unraveling biological effects that occur much earlier in the immunotherapy timeline. Magnetic resonance imaging (MRI) is a highly versatile imaging modality, where the image contrast can be tailored to emphasize a particular biophysical property of interest using advanced engineering of the imaging pipeline. In this review, recent advances in molecular-MRI based cancer immunotherapy monitoring are described. Next, the presentation of the underlying physics, computational, and biological features are complemented by a critical analysis of the results obtained in preclinical and clinical studies. Finally, emerging artificial intelligence (AI)-based strategies to further distill, quantify, and interpret the image-based molecular MRI information are discussed in terms of perspectives for the future.
Collapse
|
41
|
Zhao Y, Sun C, Zu Z. Assignment of molecular origins of NOE signal at -3.5 ppm in the brain. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.02.03.526979. [PMID: 36778370 PMCID: PMC9915742 DOI: 10.1101/2023.02.03.526979] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Purpose Nuclear Overhauser Enhancement mediated saturation transfer effect, termed NOE(-3.5 ppm), is a major source of chemical exchange saturation transfer (CEST) MRI contrasts at 3.5 ppm in the brain. Previous phantom experiments have demonstrated that both proteins and lipids, two major components in tissues, have substantial contributions to NOE(-3.5 ppm) signals. Their relative contributions in tissues are informative for the interpretation of NOE(-3.5 ppm) contrasts that could provide potential imaging biomarkers for relevant diseases, which remain incompletely understood. Methods Experiments on homogenates and supernatants of brain tissues collected from healthy rats, that could isolate proteins from lipids, were performed to evaluate the relative contribution of lipids to NOE(-3.5 ppm) signals. On the other hand, experiments on ghost membranes with varied pH, and reconstituted phospholipids with different chemical compositions were conducted to study the dependence of NOE(-3.5 ppm) on physiological conditions. Besides, CEST imaging on rat brains bearing 9L tumors and healthy rat brains was performed to analyze the causes of the NOE(-3.5 ppm) contrast variations between tumors and normal tissues, and between gray matter and white matter. Results Our experiments reveal that lipids have dominant contributions to the NOE (-3.5 ppm) signals. Further analysis suggests that decreased NOE(-3.5 ppm) signals in tumors and higher NOE(-3.5 ppm) signals in white matter than in gray matter are mainly explained by changes in membrane lipids, rather than proteins. Conclusion NOE(-3.5 ppm) could be exploited as a highly sensitive MRI contrast for imaging membrane lipids in the brain.
Collapse
|
42
|
Cui J, Sun C, Zu Z. NOE-weighted imaging in tumors using low-duty-cycle 2π-CEST. Magn Reson Med 2023; 89:636-651. [PMID: 36198015 PMCID: PMC9792266 DOI: 10.1002/mrm.29475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 08/19/2022] [Accepted: 09/12/2022] [Indexed: 02/03/2023]
Abstract
PURPOSE Nuclear Overhauser enhancement (NOE)-mediated CEST imaging at -3.5 ppm has shown clinical interest in diagnosing tumors. Multiple-pool Lorentzian fit has been used to quantify NOE, which, however, requires a long scan time. Asymmetric analysis of CEST signals could be a simple and fast method to quantify this NOE, but it has contamination from the amide proton transfer (APT) at 3.5 ppm. This work proposes a new method using an asymmetric analysis of a low-duty-cycle pulsed-CEST sequence with a flip angle of 360°, termed 2π-CEST, to reduce the contribution from APT. METHODS Simulations were used to evaluate the capability of the 2π-CEST to reduce APT. Experiments on animal tumor models were performed to show its advantages compared with the conventional asymmetric analysis. Samples of reconstituted phospholipids and proteins were used to evaluate the molecular origin of this NOE. RESULTS The 2π-CEST has reduced contribution from APT. In tumors where we show that the NOE is comparable to the APT effect, reducing the contamination from APT is crucial. The results show that the NOE signal obtained with 2π-CEST in tumor regions appears more homogeneous than that obtained with the conventional method. The phantom study showed that both phospholipids and proteins contribute to the NOE at -3.5 ppm. CONCLUSION The NOE at -3.5 ppm has a different contrast mechanism from APT and other CEST/NOE effects. The proposed 2π-CEST is more accurate than the conventional asymmetric analysis in detecting NOE, and requires much less scan time than the multiple-pool Lorentzian fit.
Collapse
Affiliation(s)
- Jing Cui
- Vanderbilt University Institute of Imaging Science, Nashville, US,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Casey Sun
- Vanderbilt University Institute of Imaging Science, Nashville, US,Department of Chemistry, University of Florida, Gainesville, US
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Nashville, US,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| |
Collapse
|
43
|
Chung J, Jin T. Average saturation efficiency filter ASEF-CEST MRI of stroke rodents. Magn Reson Med 2023; 89:565-576. [PMID: 36300851 PMCID: PMC9757140 DOI: 10.1002/mrm.29463] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 07/29/2022] [Accepted: 08/29/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE The average saturation efficiency filter (ASEF) is a novel method of improving the specificity of CEST; however, there is a mismatch between the magnetization transfer (MT) effect under high-duty cycle and low-duty cycle pulse trains. We explore measures of mitigation and the sensitivity and potential of ASEF imaging in phantoms and stroke rats. METHODS Simulation and nicotinamide phantoms in denatured protein were used to investigate the effect of different average saturation powers and MT pool parameters on matching coefficients used for correction as well as the ASEF ratio signal and baseline. Then, in vivo studies were performed in stroke rodents to further investigate the sensitivity and fidelity of ASEF ratio spectra. RESULTS Simulation and studies of nicotinamide phantoms show that the matching coefficient needed to correct the baseline MT mismatch is strongly dependent on the average saturation power. In vivo studies in stroke rodents show that the matching coefficient required to correct the baseline MT mismatch is different for normal versus ischemic tissue. Thus, a baseline correction was performed to further suppress the residue MT mismatch. After correction of the mismatch, ASEF ratio achieved comparable contrast at 3.6 ppm between normal and ischemic tissue when compared to the apparent amide proton transfer (APT*) approach. Moreover, contrasts for 2.0 and 2.6 ppm were also ascertainable from the same spectra. CONCLUSION ASEF can improve the CEST signal specificity of slow exchange labile protons such as amide and guanidyl, with small loss to sensitivity. It has strong potential in the CEST imaging of various diseases.
Collapse
Affiliation(s)
- Julius Chung
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
44
|
Hu J, Xie X, Zhou W, Hu X, Sun X. The emerging potential of quantitative MRI biomarkers for the early prediction of brain metastasis response after stereotactic radiosurgery: a scoping review. Quant Imaging Med Surg 2023; 13:1174-1189. [PMID: 36819250 PMCID: PMC9929394 DOI: 10.21037/qims-22-412] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 11/23/2022] [Indexed: 01/05/2023]
Abstract
Background At present, the simple prognostic models based on clinical information for predicting the treatment outcomes of brain metastases (BMs) are subjective and delayed. Thus, we performed this systematic review of multiple studies to assess the potential of quantitative magnetic resonance imaging (MRI) biomarkers for the early prediction of treatment outcomes of brain metastases with stereotactic radiosurgery (SRS). Methods We systematically searched the PubMed, Embase, Cochrane, Web of Science, and Clinical Trials.gov databases for articles published between February 1, 1991, and April 11, 2022, with no language restrictions. We included studies involving patients with BMs receiving SRS; the included patients were required to have definite pathology of a primary tumor and complete imaging data (pre- and post-SRS). We excluded the articles that included patients who had undergone previous surgery and those that did not include regular follow-up or corresponding MRI scans. Results We identified 2,162 studies, of which 26 were included in our analysis, involving a total of 1,362 participants. All 26 studies explored the relevant MRI parameters to predict the prognosis of patients with BMs who received SRS. The outcomes were generalized according to the relationships between the anatomical/morphological, microstructural, vascular, and metabolic changes and SRS. Generally, with traditional MRI, there are several quantitative prognostic models based on preradiosurgical radiomics that predict the outcome of SRS treatment in local BM control. With the implementation of advanced MRI, the relative apparent diffusion coefficient (ADC), perfusion fraction (f), relative cerebral blood volume (rCBV), relative regional cerebral blood flow (rrCBF), interstitial fluid pressure (IFP), quadratic of time-dependent leakage (Ktrans 2), extracellular extravascular volume (ve), choline/creatine (Cho/Cr), nuclear Overhauser effect (NOE) peak, and intraextracellular water exchange rate constant (kIE ) were confirmed to be indicative of the therapeutic effect of SRS for BMs. Conclusions Quantitative MRI biomarkers extracted from traditional or advanced MRI at different time points, which can represent the anatomical/morphological, microstructural, vascular, and metabolic changes, respectively, have been proposed as promising markers for the early prediction of SRS response in those with BMs. There are some limitations in this review, including the risk of selection bias, the limited number of study objects, the incomparability of the total data, and the subjectivity of the review process.
Collapse
Affiliation(s)
- Jiamiao Hu
- Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University, School of Medicine, Hangzhou, China
| | - Xuyun Xie
- Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University, School of Medicine, Hangzhou, China
| | - Weiwen Zhou
- Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University, School of Medicine, Hangzhou, China
| | - Xiao Hu
- Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University, School of Medicine, Hangzhou, China
| | - Xiaonan Sun
- Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University, School of Medicine, Hangzhou, China
| |
Collapse
|
45
|
Wang F, Xiang YS, Wu P, Shen AJ, Wang PJ. Evaluation of amide proton transfer imaging for bladder cancer histopathologic features: A comparative study with diffusion- weighted imaging. Eur J Radiol 2023; 159:110664. [PMID: 36574743 DOI: 10.1016/j.ejrad.2022.110664] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 12/14/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
PURPOSE To assess the ability of amide proton transfer (APT) imaging, in comparison with diffusion-weighted imaging (DWI), to differentiate low-grade from high-grade bladder tumors and predict the aggressiveness of bladder cancer (BCa). METHODS Forty-eight patients diagnosed with BCa confirmed by histopathological findings who underwent magnetic resonance (MR) imaging, including APT imaging and DWI (b = 0, 1000 sec/mm2), were enrolled in this study. The asymmetric magnetization transfer ratio (MTRasym) was defined as the magnetization transfer asymmetry at 3.5 ppm. MTRasym and apparent diffusion coefficients (ADCs) were compared between the low- and high-grade groups and between non-muscle-invasive bladder cancer (NMIBC) and muscle-invasive bladder cancer (MIBC) in terms of the areas under the receiver operating characteristic curves (AUCs). RESULTS The MTRasym values were significantly higher in patients with high-grade bladder tumors than in those with low-grade tumors (1.61 % [0.76 %], 1.12 ± 0.3 %; P = 0.000) and in MIBC than in NMIBC (2.53 ± 0.67 %, 1.38 % [0.35 %]; P = 0.000). The AUCs of MTRasym were significantly larger than those of ADC for differentiating MIBC from NMIBC (0.973, 0.771; P = 0.016). Adding APT imaging to DWI significantly improved the diagnostic accuracy for differentiating MIBC from NMIBC versus DWI alone (0.985, 0.876; P = 0.013). CONCLUSIONS APT imaging can predict tumor grade and aggressiveness in BCa. The diagnostic performance of APT imaging in predicting tumor aggressiveness was better than that of DWI, and adding APT imaging to DWI significantly improved the diagnostic accuracy of predicting tumor aggressiveness versus DWI alone.
Collapse
Affiliation(s)
- Fang Wang
- Department of Radiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai 200065, China
| | - Yong-Sheng Xiang
- Department of Radiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai 200065, China
| | - Peng Wu
- Philips Healthcare, Shanghai 200072, China
| | - Ai-Jun Shen
- Department of Radiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai 200065, China
| | - Pei-Jun Wang
- Department of Radiology, Tongji Hospital, School of Medicine, Tongji University, Shanghai 200065, China.
| |
Collapse
|
46
|
Evaluation of Brain Tumors Using Amide Proton Transfer Imaging: A Comparison of Normal Amide Proton Transfer Signal With Abnormal Amide Proton Transfer Signal Value. J Comput Assist Tomogr 2023; 47:121-128. [PMID: 36112043 DOI: 10.1097/rct.0000000000001378] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE The aim of the study was to evaluate the relationship of amide proton transfer (APT) signal characteristics in brain tumors and uninvolved brain tissue for patients with glioblastoma and those with brain metastases. METHODS Using the mDIXON 3D-APT sequence of the fast spin echo method, an APT image was obtained. The mean APT signal values of tumor core, peritumor edema, ipsilateral normal-appearing white matter (INAWM), and contralateral normal white matter (CNAWM) were obtained and compared between glioblastoma and brain metastases. Receiver operating characteristic curves were used to evaluate parameters for distinguishing between glioblastoma and brain metastases. In addition, the difference and change rate in APT signal values between tumor core and peritumoral edema (PE) and CNAWM were evaluated, respectively. RESULTS The APT signal values of glioblastoma were the highest in tumor core (3.41% ± 0.49%), followed by PE (2.24% ± 0.29%), INAWM (1.35% ± 0.15%), and CNAWM (1.26% ± 0.12%, P < 0.001). The APT signal value of brain metastases was the highest in tumor core (2.74% ± 0.34%), followed by PE (1.86% ± 0.35%), INAWM (1.17% ± 0.13%), and CNAWM (1.2% ± 0.09%, P < 0.01). The APT change rate (between PE and CNAWM) was not significantly different at 78% and 56% for glioblastoma and brain metastases, respectively ( P > 0.05). CONCLUSIONS Performing APT imaging under the same parameters used in this study may aid in the identification of brain tumors.
Collapse
|
47
|
Wang K, Park S, Kamson DO, Li Y, Liu G, Xu J. Guanidinium and amide CEST mapping of human brain by high spectral resolution CEST at 3 T. Magn Reson Med 2023; 89:177-191. [PMID: 36063502 PMCID: PMC9617768 DOI: 10.1002/mrm.29440] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 08/01/2022] [Accepted: 08/11/2022] [Indexed: 11/09/2022]
Abstract
PURPOSE To extract guanidinium (Guan) and amide CEST on the human brain at 3 T MRI with the high spectral resolution (HSR) CEST combined with the polynomial Lorentzian line-shape fitting (PLOF). METHODS Continuous wave (cw) turbo spin-echo (TSE) CEST was implemented to obtain the optimum saturation parameters. Both Guan and amide CEST peaks were extracted and quantified using the PLOF method. The NMR spectra on the egg white phantoms were acquired to reveal the fitting range and the contributions to the amide and GuanCEST. Two types of CEST approaches, including cw gradient- and spin-echo (cwGRASE) and steady state EPI (ssEPI), were implemented to acquire multi-slice HSR-CEST. RESULTS GuanCEST can be extracted with the PLOF method at 3 T, and the optimumB 1 = 0.6 μ T $$ {\mathrm{B}}_1=0.6\kern0.2em \upmu \mathrm{T} $$ was determined for GuanCEST in white matter (WM) and 1.0 μT in gray matter (GM). The optimum B1 = 0.8-1 μT was found for amideCEST. AmideCEST is lower in both WM and GM collected with ssEPI compared to those by cwGRASE (ssEPI = [1.27-1.63]%; cwGRASE = [2.19-2.25]%). The coefficients of variation (COV) of the amide and Guan CEST in both WM and GM for ssEPI (COV: 28.6-33.4%) are significantly higher than those of cwGRASE (COV: 8.6-18.8%). Completely different WM/GM contrasts for Guan and amide CEST were observed between ssEPI and cwGRASE. The amideCEST was found to have originated from the unstructured amide protons as suggested by the NMR spectrum of the unfolded proteins in egg white. CONCLUSION Guan and amide CEST mapping can be achieved by the HSR-CEST at 3 T combing with the PLOF method.
Collapse
Affiliation(s)
- Kexin Wang
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Sooyeon Park
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Department of Neuroscience, Johns Hopkins University, Baltimore, MD, USA
| | - David Olayinka Kamson
- The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins University, Baltimore, Maryland, USA
| | - Yuguo Li
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Guanshu Liu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
48
|
Wamelink IJHG, Kuijer JPA, Padrela BE, Zhang Y, Barkhof F, Mutsaerts HJMM, Petr J, van de Giessen E, Keil VC. Reproducibility of 3 T APT-CEST in Healthy Volunteers and Patients With Brain Glioma. J Magn Reson Imaging 2023; 57:206-215. [PMID: 35633282 PMCID: PMC10084114 DOI: 10.1002/jmri.28239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 04/28/2022] [Accepted: 04/29/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND Amide proton transfer (APT) imaging is a chemical exchange saturation transfer (CEST) technique offering potential clinical applications such as diagnosis, characterization, and treatment planning and monitoring in glioma patients. While APT-CEST has demonstrated high potential, reproducibility remains underexplored. PURPOSE To investigate whether cerebral APT-CEST with clinically feasible scan time is reproducible in healthy tissue and glioma for clinical use at 3 T. STUDY TYPE Prospective, longitudinal. SUBJECTS Twenty-one healthy volunteers (11 females; mean age ± SD: 39 ± 11 years) and 6 glioma patients (3 females; 50 ± 17 years: 4 glioblastomas, 1 oligodendroglioma, 1 radiologically suspected low-grade glioma). FIELD STRENGTH/SEQUENCE 3 T, Turbo Spin Echo - ampling perfection with application optimized contrasts using different flip angle evolution - chemical exchange saturation transfer (TSE SPACE-CEST). ASSESSMENT APT-CEST measurement reproducibility was assessed within-session (glioma patients, scan session 1; healthy volunteers scan sessions 1, 2, and 3), between-sessions (healthy volunteers scan sessions 1 and 2), and between-days (healthy volunteers, scan sessions 1 and 3). The mean APTCEST values and standard deviation of the within-subject difference (SDdiff ) were calculated in whole tumor enclosed by regions of interest (ROIs) in patients, and eight ROIs in healthy volunteers-whole-brain, cortical gray matter, putamen, thalami, orbitofrontal gyri, occipital lobes, central brain-and compared. STATISTICAL TESTS Brown-Forsythe tests and variance component analysis (VCA) were used to assess the reproducibility of ROIs for the three time intervals. Significance was set at P < 0.003 after Bonferroni correction. RESULTS Intratumoral mean APTCEST was significantly higher than APTCEST in healthy-appearing tissue in patients (0.5 ± 0.46%). The average within-session, between-sessions, and between-days SDdiff of healthy control brains was 0.2% and did not differ significantly with each other (0.76 > P > 0.22). The within-session SDdiff of whole-brain was 0.2% in both healthy volunteers and patients, and 0.21% in the segmented tumor. VCA showed that within-session factors were the most important (60%) for scanning variance. DATA CONCLUSION Cerebral APT-CEST imaging may show good scan-rescan reproducibility in healthy tissue and tumors with clinically feasible scan times at 3 T. Short-term measurement effects may be the dominant components for reproducibility. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Ivar J H G Wamelink
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Joost P A Kuijer
- Department of Radiology and Nuclear Medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Beatriz E Padrela
- Department of Radiology and Nuclear Medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Frederik Barkhof
- Department of Radiology and Nuclear Medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands.,Queen Square Institute of Neurology and Centre for Medical Image Computing, University College London, London, UK
| | - Henk J M M Mutsaerts
- Department of Radiology and Nuclear Medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Jan Petr
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam, Amsterdam University Medical Center, Amsterdam, The Netherlands.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Dresden, Germany
| | - Elsmarieke van de Giessen
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam, Amsterdam University Medical Center, Amsterdam, The Netherlands.,Department of Radiology and Nuclear Medicine, Amsterdam Neuroscience, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Vera C Keil
- Department of Radiology and Nuclear Medicine, Cancer Center Amsterdam, Amsterdam University Medical Center, Amsterdam, The Netherlands
| |
Collapse
|
49
|
Cohen O, Yu VY, Tringale KR, Young RJ, Perlman O, Farrar CT, Otazo R. CEST MR fingerprinting (CEST-MRF) for brain tumor quantification using EPI readout and deep learning reconstruction. Magn Reson Med 2023; 89:233-249. [PMID: 36128888 PMCID: PMC9617776 DOI: 10.1002/mrm.29448] [Citation(s) in RCA: 16] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 08/09/2022] [Accepted: 08/19/2022] [Indexed: 01/21/2023]
Abstract
PURPOSE To develop a clinical CEST MR fingerprinting (CEST-MRF) method for brain tumor quantification using EPI acquisition and deep learning reconstruction. METHODS A CEST-MRF pulse sequence originally designed for animal imaging was modified to conform to hardware limits on clinical scanners while keeping scan time under 2 min. Quantitative MRF reconstruction was performed using a deep reconstruction network (DRONE) to yield the water relaxation and chemical exchange parameters. The feasibility of the six parameter DRONE reconstruction was tested in simulations using a digital brain phantom. A healthy subject was scanned with the CEST-MRF sequence, conventional MRF and CEST sequences for comparison. Reproducibility was assessed via test-retest experiments and the concordance correlation coefficient calculated for white matter and gray matter. The clinical utility of CEST-MRF was demonstrated on four patients with brain metastases in comparison to standard clinical imaging sequences. Tumors were segmented into edema, solid core, and necrotic core regions and the CEST-MRF values compared to the contra-lateral side. RESULTS DRONE reconstruction of the digital phantom yielded a normalized RMS error of ≤7% for all parameters. The CEST-MRF parameters were in good agreement with those from conventional MRF and CEST sequences and previous studies. The mean concordance correlation coefficient for all six parameters was 0.98 ± 0.01 in white matter and 0.98 ± 0.02 in gray matter. The CEST-MRF values in nearly all tumor regions were significantly different (P = 0.05) from each other and the contra-lateral side. CONCLUSION Combination of EPI readout and deep learning reconstruction enabled fast, accurate and reproducible CEST-MRF in brain tumors.
Collapse
Affiliation(s)
- Ouri Cohen
- Department of Medical PhysicsMemorial Sloan Kettering Cancer Center
New YorkNew YorkUSA
| | - Victoria Y. Yu
- Department of Medical PhysicsMemorial Sloan Kettering Cancer Center
New YorkNew YorkUSA
| | - Kathryn R. Tringale
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Robert J. Young
- Department of RadiologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Or Perlman
- Athinoula A. Martinos Center for Biomedical Imaging, Department of RadiologyMassachusetts General Hospital and Harvard Medical SchoolCharlestownMassachusettsUSA
- Department of Biomedical EngineeringTel Aviv UniversityTel AvivIsrael
- Sagol School of NeuroscienceTel Aviv UniversityTel AvivIsrael
| | - Christian T. Farrar
- Athinoula A. Martinos Center for Biomedical Imaging, Department of RadiologyMassachusetts General Hospital and Harvard Medical SchoolCharlestownMassachusettsUSA
| | - Ricardo Otazo
- Department of Medical PhysicsMemorial Sloan Kettering Cancer Center
New YorkNew YorkUSA
- Department of RadiologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| |
Collapse
|
50
|
Jabehdar Maralani P, Chan RW, Lam WW, Oakden W, Oglesby R, Lau A, Mehrabian H, Heyn C, Chan AK, Soliman H, Sahgal A, Stanisz GJ. Chemical Exchange Saturation Transfer MRI: What Neuro-Oncology Clinicians Need To Know. Technol Cancer Res Treat 2023; 22:15330338231208613. [PMID: 37872686 PMCID: PMC10594966 DOI: 10.1177/15330338231208613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/19/2023] [Accepted: 09/28/2023] [Indexed: 10/25/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) is a relatively novel magnetic resonance imaging (MRI) technique with an image contrast designed for in vivo measurement of certain endogenous molecules with protons that are exchangeable with water protons, such as amide proton transfer commonly used for neuro-oncology applications. Recent technological advances have made it feasible to implement CEST on clinical grade scanners within practical acquisition times, creating new opportunities to integrate CEST in clinical workflow. In addition, the majority of CEST applications used in neuro-oncology are performed without the use gadolinium-based contrast agents which are another appealing feature of this technique. This review is written for clinicians involved in neuro-oncologic care (nonphysicists) as the target audience explaining what they need to know as CEST makes its way into practice. The purpose of this article is to (1) review the basic physics and technical principles of CEST MRI, and (2) review the practical applications of CEST in neuro-oncology.
Collapse
Affiliation(s)
- Pejman Jabehdar Maralani
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Rachel W. Chan
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Wilfred W. Lam
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Wendy Oakden
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Ryan Oglesby
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Angus Lau
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| | - Hatef Mehrabian
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Chris Heyn
- Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Aimee K.M. Chan
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
| | - Hany Soliman
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Arjun Sahgal
- Department of Radiation Oncology, University of Toronto, Toronto, ON, Canada
| | - Greg J. Stanisz
- Physical Sciences, Sunnybrook Research Institute, Toronto, ON, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
| |
Collapse
|