1
|
Pope BL, Zhang M, Jo S, Dragnea B, Jacobson SC. Microscale Diffractive Lenses Integrated into Microfluidic Devices for Size-Selective Optical Trapping of Particles. Anal Chem 2024; 96:11845-11852. [PMID: 38976499 DOI: 10.1021/acs.analchem.4c01521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
Abstract
Integration of optical components into microfluidic devices can enhance particle manipulations, separations, and analyses. We present a method to fabricate microscale diffractive lenses composed of aperiodically spaced concentric rings milled into a thin metal film to precisely position optical tweezers within microfluidic channels. Integrated thin-film microlenses perform the laser focusing required to generate sufficient optical forces to trap particles without significant off-device beam manipulation. Moreover, the ability to trap particles with unfocused laser light allows multiple optical traps to be powered simultaneously by a single input laser. We have optically trapped polystyrene particles with diameters of 0.5, 1, 2, and 4 μm over microlenses fabricated in chromium and gold films. Optical forces generated by these microlenses captured particles traveling at fluid velocities up to 64 μm/s. Quantitative trapping experiments with particles in microfluidic flow demonstrate size-based differential trapping of neutrally buoyant particles where larger particles required a stronger trapping force. The optical forces on these particles are identical to traditional optical traps, but the addition of a continuous viscous drag force from the microfluidic flow introduces tunable size selectivity across a range of laser powers and fluid velocities.
Collapse
Affiliation(s)
- Brigham L Pope
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405-7102, United States
| | - Mi Zhang
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405-7102, United States
| | - Suhun Jo
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405-7102, United States
| | - Bogdan Dragnea
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405-7102, United States
| | - Stephen C Jacobson
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405-7102, United States
| |
Collapse
|
2
|
Astrath NGC, Bergmann EV, Anghinoni B, Flizikowski GAS, Novatski A, Jacinto C, Požar T, Kalin M, Malacarne LC, Baesso ML. Towards a comprehensive characterization of spatio-temporal dependence of light-induced electromagnetic forces in dielectric liquids. Sci Rep 2024; 14:5595. [PMID: 38454075 PMCID: PMC10920765 DOI: 10.1038/s41598-024-56176-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Accepted: 03/03/2024] [Indexed: 03/09/2024] Open
Abstract
The interaction of localized light with matter generates optical electrostriction within dielectric fluids, leading to a discernible change in the refractive index of the medium according to the excitation's light profile. This optical force holds critical significance in optical manipulation and plays a fundamental role in numerous photonic applications. In this study, we demonstrate the applicability of the pump-probe, photo-induced lensing (PIL) method to investigate optical electrostriction in various dielectric liquids. Notably, the thermal and nonlinear effects are observed to be temporally decoupled from the electrostriction effects, facilitating isolated observation of the latter. Our findings provide a comprehensive explanation of optical forces in the context of the recently introduced microscopic Ampère electromagnetic formalism, which is grounded in the dipolar approximation of electromagnetic sources within matter and characterizes electrostriction as an electromagnetic-induced stress within the medium. Here, the optical force density is re-obtained through a new Lagrangian approach.
Collapse
Affiliation(s)
- N G C Astrath
- Department of Physics, Universidade Estadual de Maringá, Maringá, PR, 87020-900, Brazil.
| | - E V Bergmann
- Department of Physics, Universidade Estadual de Maringá, Maringá, PR, 87020-900, Brazil
| | - B Anghinoni
- Department of Physics, Universidade Estadual de Maringá, Maringá, PR, 87020-900, Brazil
| | - G A S Flizikowski
- School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON, K1N6N5, Canada
| | - A Novatski
- Department of Physics, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, 84030-900, Brazil
| | - C Jacinto
- Institute of Physics, Universidade Federal de Alagoas, Maceió, AL, 57072-900, Brazil
| | - T Požar
- Faculty of Mechanical Engineering, University of Ljubljana, 1000, Ljubljana, Slovenia
| | - M Kalin
- Faculty of Mechanical Engineering, University of Ljubljana, 1000, Ljubljana, Slovenia
| | - L C Malacarne
- Department of Physics, Universidade Estadual de Maringá, Maringá, PR, 87020-900, Brazil
| | - M L Baesso
- Department of Physics, Universidade Estadual de Maringá, Maringá, PR, 87020-900, Brazil
| |
Collapse
|
3
|
Shang L, Liang P, Xu L, Xue Y, Liu K, Wang Y, Bao X, Chen F, Peng H, Wang Y, Ju J, Li B. Stable SERS Detection of Lactobacillus fermentum Using Optical Tweezers in a Microfluidic Environment. Anal Chem 2024; 96:248-255. [PMID: 38113377 DOI: 10.1021/acs.analchem.3c03852] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
Rapid identification of fermented lactic acid bacteria has long been a challenge in the brewing industry. This study combined label-free surface-enhanced Raman scattering (SERS) and optical tweezer technology to construct a test platform within a microfluidic environment. Six kinds of lactic acid bacteria common in industry were tested to prove the stability of the SERS spectra. The results demonstrated that the utilization of optical tweezers to securely hold the bacteria significantly enhanced the stability of the SERS spectra. Furthermore, SVM and XGBoost machine learning algorithms were utilized to analyze the obtained Raman spectra for identification, and the identification accuracies exceeded 95% for all tested lactic acid bacteria. The findings of this study highlight the crucial role of optical tweezers in improving the stability of SERS spectra by capturing bacteria in a microfluidic environment, prove that this technology could be used in the rapid identification of lactic acid bacteria, and show great significance in expanding the applicability of the SERS technique for other bacterial testing purposes.
Collapse
Affiliation(s)
- Lindong Shang
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Peng Liang
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Lei Xu
- National Engineering Research Center for Cereal Fermentation and Food Biomanufacturing, Jiangnan University, Wuxi 214122, P. R. China
| | - Ying Xue
- HOOKE Instruments Ltd, Changchun 130031, P. R. China
| | - Kunxiang Liu
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Yuntong Wang
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Xiaodong Bao
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Fuyuan Chen
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Hao Peng
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Yu Wang
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Jian Ju
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou 325001, P. R. China
| | - Bei Li
- Key Laboratory of Optical System Advanced Manufacturing Technology, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
- HOOKE Instruments Ltd, Changchun 130031, P. R. China
| |
Collapse
|
4
|
Valle M, O'Brien B, Green TD, Reiner JE, Seashols-Williams S. Droplet-based optical trapping for cell separation in mock forensic samples. J Forensic Sci 2024; 69:273-281. [PMID: 37710383 DOI: 10.1111/1556-4029.15379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/14/2023] [Accepted: 09/05/2023] [Indexed: 09/16/2023]
Abstract
Optical tweezers have a wide range of uses for mechanical manipulation of objects in the microscopic range. This includes both living and static cells in a variety of biomedical and research applications. Single-focus optical tweezers, formed by focusing a laser beam through a high numerical aperture immersion objective, create a significant force, which enables controlled transport of a variety of different cell types and morphologies in three dimensions. Optical tweezers have been previously reported to capture and separate spermatozoa from a reconstituted simulated postcoital sample. We report herein the development of a simplified, more efficient cell transfer protocol that can separate and isolate both spermatozoa as well as leukocytes, with similar efficiencies as those previously reported. The new cell transfer method was used to separate sperm cells from a reconstituted mixture of spermatozoa and vaginal epithelial cells, with complete STR profiles developed from 50 cells with little evidence of contribution from the female contributor to the mixture. This modified protocol was then used to separate 21 samples of enriched leukocytes, with trapped cells ranging from 5 to 22 cells. Complete STR profiles were developed from as few as 10 leukocytes. Thus, with minimal sample preparation and a short trapping time, this method has the potential to provide an alternative to traditional differential extraction methods for separation of sperm:nonsperm mixtures while also providing versatility for separation of cells with differing morphologies.
Collapse
Affiliation(s)
- Michael Valle
- Department of Forensic Science, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Benjamin O'Brien
- Department of Forensic Science, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Tracey Dawson Green
- Department of Forensic Science, Virginia Commonwealth University, Richmond, Virginia, USA
| | - Joseph E Reiner
- Department of Physics, Virginia Commonwealth University, Richmond, Virginia, USA
| | | |
Collapse
|
5
|
Zhao J, Bai C, Zhang Z, Zhang Q. Deep learning-based method for analyzing the optically trapped sperm rotation. Sci Rep 2023; 13:12575. [PMID: 37537346 PMCID: PMC10400645 DOI: 10.1038/s41598-023-39819-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 07/31/2023] [Indexed: 08/05/2023] Open
Abstract
Optical tweezers exert a strong trapping force on cells, making it crucial to analyze the movement of trapped cells. The rotation of cells plays a significant role in their swimming patterns, such as in sperm cells. We proposed a fast deep-learning-based method that can automatically determine the projection orientation of ellipsoidal-like cells without additional optical design. This method was utilized for analyzing the planar rotation of trapped sperm cells using an optical tweezer, demonstrating its feasibility in extracting the rotation of the cell head. Furthermore, we employed this method to investigate sperm cell activity by examining variations in sperm rotation rates under different conditions, including temperature and laser output power. Our findings provide evidence for the effectiveness of this method and the rotation analysis method developed may have clinical potential for sperm quality evaluation.
Collapse
Affiliation(s)
- Jiangcheng Zhao
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230027, China
| | - Chuanbiao Bai
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230027, China
| | - Zhiguo Zhang
- School of Biomedical Engineering, Anhui Provincial Institute of Translational Medicine, Anhui Medical University, Hefei, 230027, China
| | - Qingchuan Zhang
- CAS Key Laboratory of Mechanical Behavior and Design of Materials, Department of Modern Mechanics, University of Science and Technology of China, Hefei, 230027, China.
| |
Collapse
|
6
|
Dradrach K, Zmyślony M, Deng Z, Priimagi A, Biggins J, Wasylczyk P. Light-driven peristaltic pumping by an actuating splay-bend strip. Nat Commun 2023; 14:1877. [PMID: 37015926 PMCID: PMC10073117 DOI: 10.1038/s41467-023-37445-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Accepted: 03/15/2023] [Indexed: 04/06/2023] Open
Abstract
Despite spectacular progress in microfluidics, small-scale liquid manipulation, with few exceptions, is still driven by external pumps and controlled by large-scale valves, increasing cost and size and limiting complexity. By contrast, optofluidics uses light to power, control and monitor liquid manipulation, potentially allowing for small, self-contained microfluidic devices. Here we demonstrate a soft light-propelled actuator made of liquid crystal gel that pumps microlitre volumes of water. The strip of actuating material serves as both a pump and a channel leading to an extremely simple microfluidic architecture that is both powered and controlled by light. The performance of the pump is well explained by a simple theoretical model in which the light-induced bending of the actuator competes with the liquid's surface tension. The theory highlights that effective pumping requires a threshold light intensity and strip width. The proposed system explores the benefits of shifting the complexity of microfluidic systems from the fabricated device to spatio-temporal control over stimulating light patterns.
Collapse
Affiliation(s)
- Klaudia Dradrach
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom.
- Faculty of Physics, University of Warsaw, Warsaw, Poland.
| | - Michał Zmyślony
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Zixuan Deng
- Faculty of Engineering and Natural Sciences, Tampere University, Tampere, Finland
| | - Arri Priimagi
- Faculty of Engineering and Natural Sciences, Tampere University, Tampere, Finland
| | - John Biggins
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom.
| | | |
Collapse
|
7
|
Riccardi M, Martin OJF. Electromagnetic Forces and Torques: From Dielectrophoresis to Optical Tweezers. Chem Rev 2023; 123:1680-1711. [PMID: 36719985 PMCID: PMC9951227 DOI: 10.1021/acs.chemrev.2c00576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Indexed: 02/02/2023]
Abstract
Electromagnetic forces and torques enable many key technologies, including optical tweezers or dielectrophoresis. Interestingly, both techniques rely on the same physical process: the interaction of an oscillating electric field with a particle of matter. This work provides a unified framework to understand this interaction both when considering fields oscillating at low frequencies─dielectrophoresis─and high frequencies─optical tweezers. We draw useful parallels between these two techniques, discuss the different and often unstated assumptions they are based upon, and illustrate key applications in the fields of physical and analytical chemistry, biosensing, and colloidal science.
Collapse
Affiliation(s)
- Marco Riccardi
- Nanophotonics and Metrology Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), EPFL-STI-NAM, Station 11, CH-1015Lausanne, Switzerland
| | - Olivier J. F. Martin
- Nanophotonics and Metrology Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), EPFL-STI-NAM, Station 11, CH-1015Lausanne, Switzerland
| |
Collapse
|
8
|
Biochemical analysis based on optical detection integrated microfluidic chip. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2022.116865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
9
|
Duran C, Zhang S, Yang C, Falco ML, Cravo-Laureau C, Suzuki-Minakuchi C, Nojiri H, Duran R, Sassa F. Low-cost gel-filled microwell array device for screening marine microbial consortium. Front Microbiol 2022; 13:1031439. [PMID: 36590440 PMCID: PMC9800614 DOI: 10.3389/fmicb.2022.1031439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022] Open
Abstract
In order to exploit the microbes present in the environment for their beneficial resources, effective selection and isolation of microbes from environmental samples is essential. In this study, we fabricated a gel-filled microwell array device using resin for microbial culture. The device has an integrated sealing mechanism that enables high-density isolation based on the culture of microorganisms; the device is easily manageable, facilitating observation using bright-field microscopy. This low-cost device made from polymethyl methacrylate (PMMA)/polyethylene terephthalate (PET) has 900 microwells (600 μm × 600 μm × 700 μm) filled with a microbial culture gel medium in glass slide-sized plates. It also has grooves for maintaining the moisture content in the micro-gel. The partition wall between the wells has a highly hydrophobic coating to inhibit microbial migration to neighboring wells and to prevent exchange of liquid substances. After being hermetically sealed, the device can maintain moisture in the agarose gels for 7 days. In the bacterial culture experiment using this device, environmental bacteria were isolated and cultured in individual wells after 3 days. Moreover, the isolated bacteria were then picked up from wells and re-cultured. This device is effective for the first screening of microorganisms from marine environmental samples.
Collapse
Affiliation(s)
- Clelia Duran
- Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM, Pau, France
| | - Shiyi Zhang
- Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Chongyang Yang
- Agro-Biotechnology Research Center, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan
| | - Maria Lorena Falco
- Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM, Pau, France
| | | | - Chiho Suzuki-Minakuchi
- Agro-Biotechnology Research Center, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan,Collaborative Research Institute for Innovative Microbiology, The University of Tokyo, Tokyo, Japan
| | - Hideaki Nojiri
- Agro-Biotechnology Research Center, Graduate School of Agricultural and Life Sciences, The University of Tokyo, Tokyo, Japan,Collaborative Research Institute for Innovative Microbiology, The University of Tokyo, Tokyo, Japan
| | - Robert Duran
- Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM, Pau, France,*Correspondence: Robert Duran, ; Fumihiro Sassa,
| | - Fumihiro Sassa
- Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan,*Correspondence: Robert Duran, ; Fumihiro Sassa,
| |
Collapse
|
10
|
Kishimoto T, Masui K, Minoshima W, Hosokawa C. Recent advances in optical manipulation of cells and molecules for biological science. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY C: PHOTOCHEMISTRY REVIEWS 2022. [DOI: 10.1016/j.jphotochemrev.2022.100554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
Favre-Bulle IA, Scott EK. Optical tweezers across scales in cell biology. Trends Cell Biol 2022; 32:932-946. [PMID: 35672197 PMCID: PMC9588623 DOI: 10.1016/j.tcb.2022.05.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/02/2022] [Accepted: 05/04/2022] [Indexed: 01/21/2023]
Abstract
Optical tweezers (OT) provide a noninvasive approach for delivering minute physical forces to targeted objects. Controlling such forces in living cells or in vitro preparations allows for the measurement and manipulation of numerous processes relevant to the form and function of cells. As such, OT have made important contributions to our understanding of the structures of proteins and nucleic acids, the interactions that occur between microscopic structures within cells, the choreography of complex processes such as mitosis, and the ways in which cells interact with each other. In this review, we highlight recent contributions made to the field of cell biology using OT and provide basic descriptions of the physics, the methods, and the equipment that made these studies possible.
Collapse
Affiliation(s)
- Itia A Favre-Bulle
- Queensland Brain Institute, The University of Queensland, 4067, Brisbane, Australia; School of Mathematics and Physics, The University of Queensland, 4067, Brisbane, Australia.
| | - Ethan K Scott
- Queensland Brain Institute, The University of Queensland, 4067, Brisbane, Australia; Department of Anatomy and Physiology, School of Biomedical Sciences, The University of Melbourne, Parkville, VIC 3010, Australia.
| |
Collapse
|
12
|
Clark MG, Gonzalez GA, Luo Y, Aldana-Mendoza JA, Carlsen MS, Eakins G, Dai M, Zhang C. Real-time precision opto-control of chemical processes in live cells. Nat Commun 2022; 13:4343. [PMID: 35896556 PMCID: PMC9329476 DOI: 10.1038/s41467-022-32071-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 07/15/2022] [Indexed: 11/29/2022] Open
Abstract
Precision control of molecular activities and chemical reactions in live cells is a long-sought capability by life scientists. No existing technology can probe molecular targets in cells and simultaneously control the activities of only these targets at high spatial precision. We develop a real-time precision opto-control (RPOC) technology that detects a chemical-specific optical response from molecular targets during laser scanning and uses the optical signal to couple a separate laser to only interact with these molecules without affecting other sample locations. We demonstrate precision control of molecular states of a photochromic molecule in different regions of the cells. We also synthesize a photoswitchable compound and use it with RPOC to achieve site-specific inhibition of microtubule polymerization and control of organelle dynamics in live cells. RPOC can automatically detect and control biomolecular activities and chemical processes in dynamic living samples with submicron spatial accuracy, fast response time, and high chemical specificity. There is a need to control molecular activities at high spatial precision. Here the authors report a real-time precision opto-control technology that detects a chemical-specific optical response from molecular targets, and precisely control photoswitchable microtubule polymerization inhibitors in cells.
Collapse
Affiliation(s)
- Matthew G Clark
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Gil A Gonzalez
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Yiyang Luo
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Jesus A Aldana-Mendoza
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Mark S Carlsen
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Gregory Eakins
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA
| | - Mingji Dai
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA.,Purdue Center for Cancer Research, 201 S. University St., West Lafayette, IN, 47907, USA
| | - Chi Zhang
- Department of Chemistry, Purdue University, 560 Oval Dr., West Lafayette, IN, 47907, USA. .,Purdue Center for Cancer Research, 201 S. University St., West Lafayette, IN, 47907, USA. .,Purdue Institute of Inflammation, Immunology, and Infectious Disease, 207 S. Martin Jischke Dr., West Lafayette, IN, 47907, USA.
| |
Collapse
|
13
|
Optical tweezers integrated surface plasmon resonance holographic microscopy for characterizing cell-substrate interactions under noninvasive optical force stimuli. Biosens Bioelectron 2022; 206:114131. [DOI: 10.1016/j.bios.2022.114131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 02/10/2022] [Accepted: 02/22/2022] [Indexed: 11/23/2022]
|
14
|
Liu XP, Zhang WS, Wang YN, Ye WQ, Xu ZR. In situ monitoring PUVA therapy by using a cell-array chip-based SERS platform. Anal Chim Acta 2022; 1189:339224. [PMID: 34815036 DOI: 10.1016/j.aca.2021.339224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 10/26/2021] [Accepted: 10/27/2021] [Indexed: 11/25/2022]
Abstract
Psoralen ultraviolet A (PUVA) therapy has thrived as a promising treatment for psoriasis. However, overdose of PUVA treatment will cause side-effects, such as melanoma formation. And these side-effects are often ignored during PUVA therapy. Hence, in situ monitoring therapeutic response of PUVA therapy is important to minimize side-effects. Aberrant expression of tyrosinase (TYR) has been proved to be associated with melanoma, indicating that TYR is a potential target for evaluation of PUVA therapy. Herein, we reported a strategy for in situ monitoring TYR activity during PUVA therapy by using a cell-array chip-based SERS platform. The cell-array chip was used to simulate cell survival environment for cell culture. Capture of single cells and living cell analysis were realized in the isolated microchambers. An enzyme-induced core-shell self-assembly substrate was used to evaluate TYR activity in living cells during PUVA therapy. The gold nanoparticle modified with a SERS reporter, 4-mercaptobenzonitrile (4-MBN), was used as the core. In the presence of oxygen and TYR, hydroxylation of l-tyrosine occurred, leading to the reduction of silver ion on the surface of gold cores. The growth of silver shells was accompanied by the increased SERS intensity of the reporter, which is related directly to TYR activity. The detection limit for TYR activity is 0.45 U/mL. Upregulation of TYR activity was successfully monitored after PUVA therapy. Notably, real-time and in situ information of therapeutic response can be obtained through monitoring PUVA therapy by using a cell-array chip-based SERS platform, which has great potential to guide the clinical application of PUVA therapy.
Collapse
Affiliation(s)
- Xiao-Peng Liu
- Research Center for Analytical Sciences, Northeastern University, Shenyang, 110819, PR China
| | - Wen-Shu Zhang
- Research Center for Analytical Sciences, Northeastern University, Shenyang, 110819, PR China
| | - Ya-Ning Wang
- Research Center for Analytical Sciences, Northeastern University, Shenyang, 110819, PR China
| | - Wen-Qi Ye
- Research Center for Analytical Sciences, Northeastern University, Shenyang, 110819, PR China
| | - Zhang-Run Xu
- Research Center for Analytical Sciences, Northeastern University, Shenyang, 110819, PR China.
| |
Collapse
|
15
|
Zhang Y, Zhou A, Chen S, Lum GZ, Zhang X. A perspective on magnetic microfluidics: Towards an intelligent future. BIOMICROFLUIDICS 2022; 16:011301. [PMID: 35069962 PMCID: PMC8769766 DOI: 10.1063/5.0079464] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Accepted: 01/02/2022] [Indexed: 05/09/2023]
Abstract
Magnetic microfluidics has been gradually recognized as an area of its own. Both conventional microfluidic platforms have incorporated magnetic actuation for microfluidic operation and microscale object manipulation. Nonetheless, there is still much room for improvement after decades of development. In this Perspective, we first provide a quick review of existing magnetic microfluidic platforms with a focus on the magnetic tools and actuation mechanisms. Next, we discuss several emerging technologies, including magnetic microrobots, additive manufacture, and artificial intelligence, and their potential application in the future development of magnetic microfluidics. We believe that these technologies can eventually inspire highly functional magnetic tools for microfluidic manipulation and coordinated microfluidic control at the system level, which eventually drives magnetic microfluidics into an intelligent system for automated experimentation.
Collapse
Affiliation(s)
- Yi Zhang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China Chengdu, China
- Authors to whom correspondence should be addressed:; ;
and
| | - Aiwu Zhou
- Singapore Centre for 3D Printing, School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
| | - Songlin Chen
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
| | - Guo Zhan Lum
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Singapore
- Authors to whom correspondence should be addressed:; ;
and
| | - Xiaosheng Zhang
- School of Electronic Science and Engineering, University of Electronic Science and Technology of China Chengdu, China
- Authors to whom correspondence should be addressed:; ;
and
| |
Collapse
|
16
|
Modeling Brownian Microparticle Trajectories in Lab-on-a-Chip Devices with Time Varying Dielectrophoretic or Optical Forces. MICROMACHINES 2021; 12:mi12101265. [PMID: 34683316 PMCID: PMC8539052 DOI: 10.3390/mi12101265] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 01/02/2023]
Abstract
Lab-on-a-chip (LOC) devices capable of manipulating micro/nano-sized samples have spurred advances in biotechnology and chemistry. Designing and analyzing new and more advanced LOCs require accurate modeling and simulation of sample/particle dynamics inside such devices. In this work, we present a generalized computational physics model to simulate particle/sample trajectories under the influence of dielectrophoretic or optical forces inside LOC devices. The model takes into account time varying applied forces, Brownian motion, fluid flow, collision mechanics, and hindered diffusion caused by hydrodynamic interactions. We develop a numerical solver incorporating the aforementioned physics and use it to simulate two example cases: first, an optical trapping experiment, and second, a dielectrophoretic cell sorter device. In both cases, the numerical results are found to be consistent with experimental observations, thus proving the generality of the model. The numerical solver can simulate time evolution of the positions and velocities of an arbitrarily large number of particles simultaneously. This allows us to characterize and optimize a wide range of LOCs. The developed numerical solver is made freely available through a GitHub repository so that researchers can use it to develop and simulate new designs.
Collapse
|
17
|
Kolbow JD, Lindquist NC, Ertsgaard CT, Yoo D, Oh SH. Nano-Optical Tweezers: Methods and Applications for Trapping Single Molecules and Nanoparticles. Chemphyschem 2021; 22:1409-1420. [PMID: 33797179 DOI: 10.1002/cphc.202100004] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Revised: 03/31/2021] [Indexed: 11/10/2022]
Abstract
Optical tweezers were developed in 1970 by Arthur Ashkin as a tool for the manipulation of micron-sized particles. Ashkin's original design was then adapted for a variety of purposes, such as trapping and manipulation of biological materials[1] and the laser cooling of atoms.[2,3] More recent development has led to nano-optical tweezers, for trapping particles on the scale of only a few nanometers, and holographic tweezers, which allow for dynamic control of multiple traps in real-time. These alternatives to conventional optical tweezers have made it possible to trap single molecules and to perform a variety of studies on them. Presented here is a review of recent developments in nano-optical tweezers and their current and future applications.
Collapse
Affiliation(s)
- Joshua D Kolbow
- Department of Electrical and Computer Engineering, University of Minnesota Kenneth H. Keller Hall, 200, Union St SE, Minneapolis, MN 55455, USA
| | - Nathan C Lindquist
- Department of Physics and Engineering, Bethel University, 3900 Bethel Drive, St. Paul, MN 55112, USA
| | - Christopher T Ertsgaard
- Department of Electrical and Computer Engineering, University of Minnesota Kenneth H. Keller Hall, 200, Union St SE, Minneapolis, MN 55455, USA
| | - Daehan Yoo
- Department of Electrical and Computer Engineering, University of Minnesota Kenneth H. Keller Hall, 200, Union St SE, Minneapolis, MN 55455, USA
| | - Sang-Hyun Oh
- Department of Electrical and Computer Engineering, University of Minnesota Kenneth H. Keller Hall, 200, Union St SE, Minneapolis, MN 55455, USA
| |
Collapse
|
18
|
Zhou Q, Xia T, Liao W, Liu Y, Lin D, Yang J, Tao S. Microparticle sorting with a virtual optical chip. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:053201. [PMID: 34243253 DOI: 10.1063/5.0047316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Accepted: 04/19/2021] [Indexed: 06/13/2023]
Abstract
We proposed an automatic sorting method based on a virtual optical chip, which was formed by a complex-amplitude beam shaping system. The automatic sorting of different micro-particles was realized by the optical forces of the intensity and phase gradients of the reconstructed optical beam. The method was verified with theoretical analysis and experimental results. Compared with the traditional optical sorting methods, the proposed one does not need high-precision mechanical and/or microfluidic devices. The optical chip is flexible in structure and efficient in optical sorting and can be used in the fields of medical detection and material sensing.
Collapse
Affiliation(s)
- Quan Zhou
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Tian Xia
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Wei Liao
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Yu Liu
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Danping Lin
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Jianhe Yang
- School of Physics and Electronics, Central South University, Changsha 410083, China
| | - Shaohua Tao
- School of Physics and Electronics, Central South University, Changsha 410083, China
| |
Collapse
|
19
|
Manzoor AA, Romita L, Hwang DK. A review on microwell and microfluidic geometric array fabrication techniques and its potential applications in cellular studies. CAN J CHEM ENG 2020. [DOI: 10.1002/cjce.23875] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Ahmad Ali Manzoor
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Lauren Romita
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| | - Dae Kun Hwang
- Department of Chemical Engineering Ryerson University Toronto Ontario Canada
- Keenan Research Centre for Biomedical Science St. Michael's Hospital Toronto Ontario Canada
- Institute for Biomedical Engineering Science and Technology (iBEST) A partnership between Ryerson University and St. Michael's Hospital Toronto Ontario Canada
| |
Collapse
|
20
|
A Review of Secondary Flow in Inertial Microfluidics. MICROMACHINES 2020; 11:mi11050461. [PMID: 32354106 PMCID: PMC7280964 DOI: 10.3390/mi11050461] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/23/2020] [Accepted: 04/27/2020] [Indexed: 11/17/2022]
Abstract
Inertial microfluidic technology, which can manipulate the target particle entirely relying on the microchannel characteristic geometry and intrinsic hydrodynamic effect, has attracted great attention due to its fascinating advantages of high throughput, simplicity, high resolution and low cost. As a passive microfluidic technology, inertial microfluidics can precisely focus, separate, mix or trap target particles in a continuous and high-flow-speed manner without any extra external force field. Therefore, it is promising and has great potential for a wide range of industrial, biomedical and clinical applications. In the regime of inertial microfluidics, particle migration due to inertial effects forms multiple equilibrium positions in straight channels. However, this is not promising for particle detection and separation. Secondary flow, which is a relatively minor flow perpendicular to the primary flow, may reduce the number of equilibrium positions as well as modify the location of particles focusing within channel cross sections by applying an additional hydrodynamic drag. For secondary flow, the pattern and magnitude can be controlled by the well-designed channel structure, such as curvature or disturbance obstacle. The magnitude and form of generated secondary flow are greatly dependent on the disturbing microstructure. Therefore, many inventive and delicate applications of secondary flow in inertial microfluidics have been reported. In this review, we comprehensively summarize the usage of the secondary flow in inertial microfluidics.
Collapse
|
21
|
Morshed A, Karawdeniya BI, Bandara Y, Kim MJ, Dutta P. Mechanical characterization of vesicles and cells: A review. Electrophoresis 2020; 41:449-470. [PMID: 31967658 PMCID: PMC7567447 DOI: 10.1002/elps.201900362] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Revised: 12/05/2019] [Accepted: 12/08/2019] [Indexed: 12/30/2022]
Abstract
Vesicles perform many essential functions in all living organisms. They respond like a transducer to mechanical stress in converting the applied force into mechanical and biological responses. At the same time, both biochemical and biophysical signals influence the vesicular response in bearing mechanical loads. In recent years, liposomes, artificial lipid vesicles, have gained substantial attention from the pharmaceutical industry as a prospective drug carrier which can also serve as an artificial cell-mimetic system. The ability of these vesicles to enter through pores of even smaller size makes them ideal candidates for therapeutic agents to reach the infected sites effectively. Engineering of vesicles with desired mechanical properties that can encapsulate drugs and release as required is the prime challenge in this field. This requirement has led to the modifications of the composition of the bilayer membrane by adding cholesterol, sphingomyelin, etc. In this article, we review the manufacturing and characterization techniques of various artificial/synthetic vesicles. We particularly focus on the electric field-driven characterization techniques to determine different properties of vesicle and its membranes, such as bending rigidity, viscosity, capacitance, conductance, etc., which are indicators of their content and mobility. Similarities and differences between artificial vesicles, natural vesicles, and cells are highlighted throughout the manuscript since most of these artificial vesicles are intended for cell mimetic functions.
Collapse
Affiliation(s)
- Adnan Morshed
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| | - Buddini Iroshika Karawdeniya
- Department of Mechanical Engineering, Lyle School of Engineering, Southern Methodist University, Dallas, Texas, USA
| | - Y.M.NuwanD.Y. Bandara
- Department of Mechanical Engineering, Lyle School of Engineering, Southern Methodist University, Dallas, Texas, USA
| | - Min Jun Kim
- Department of Mechanical Engineering, Lyle School of Engineering, Southern Methodist University, Dallas, Texas, USA
| | - Prashanta Dutta
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920
| |
Collapse
|
22
|
Zheng B, Kang YF, Zhang T, Li CY, Huang S, Zhang ZL, Wu QS, Qi CB, Pang DW, Tang HW. Improving Flow Bead Assay: Combination of Near-Infrared Optical Tweezers Stabilizing and Upconversion Luminescence Encoding. Anal Chem 2020; 92:5258-5266. [DOI: 10.1021/acs.analchem.9b05800] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Bei Zheng
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
| | - Ya-Feng Kang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
| | - Ting Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
| | - Cheng-Yu Li
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Medical College, Wuhan University of Science and Technology, Wuhan 430065, People’s Republic of China
| | - Sha Huang
- Electronic information school, Wuhan University, Wuhan 430072, China
| | - Zhi-Ling Zhang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
| | - Qiong-Shui Wu
- Electronic information school, Wuhan University, Wuhan 430072, China
| | - Chu-Bo Qi
- Hubei Cancer Hospital, Wuhan, 430079, People’s Republic of China
| | - Dai-Wen Pang
- State Key Laboratory of Medicinal Chemical Biology, Tianjin Key Laboratory of Biosensing and Molecular Recognition, Research Center for Analytical Sciences, and College of Chemistry, Nankai University, Tianjin 300071, People’s Republic of China
| | - Hong-Wu Tang
- Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, People’s Republic of China
| |
Collapse
|
23
|
Zhai J, Li H, Wong AHH, Dong C, Yi S, Jia Y, Mak PI, Deng CX, Martins RP. A digital microfluidic system with 3D microstructures for single-cell culture. MICROSYSTEMS & NANOENGINEERING 2020; 6:6. [PMID: 34567621 PMCID: PMC8433300 DOI: 10.1038/s41378-019-0109-7] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 08/12/2019] [Accepted: 09/30/2019] [Indexed: 05/12/2023]
Abstract
Despite the precise controllability of droplet samples in digital microfluidic (DMF) systems, their capability in isolating single cells for long-time culture is still limited: typically, only a few cells can be captured on an electrode. Although fabricating small-sized hydrophilic micropatches on an electrode aids single-cell capture, the actuation voltage for droplet transportation has to be significantly raised, resulting in a shorter lifetime for the DMF chip and a larger risk of damaging the cells. In this work, a DMF system with 3D microstructures engineered on-chip is proposed to form semi-closed micro-wells for efficient single-cell isolation and long-time culture. Our optimum results showed that approximately 20% of the micro-wells over a 30 × 30 array were occupied by isolated single cells. In addition, low-evaporation-temperature oil and surfactant aided the system in achieving a low droplet actuation voltage of 36V, which was 4 times lower than the typical 150 V, minimizing the potential damage to the cells in the droplets and to the DMF chip. To exemplify the technological advances, drug sensitivity tests were run in our DMF system to investigate the cell response of breast cancer cells (MDA-MB-231) and breast normal cells (MCF-10A) to a widely used chemotherapeutic drug, Cisplatin (Cis). The results on-chip were consistent with those screened in conventional 96-well plates. This novel, simple and robust single-cell trapping method has great potential in biological research at the single cell level.
Collapse
Affiliation(s)
- Jiao Zhai
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
| | - Haoran Li
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
- Faculty of Science and Technology-ECE, University of Macau, Macau SAR, China
| | - Ada Hang-Heng Wong
- Cancer Center, Faculty of Health Sciences, University of Macau, Macau SAR, China
| | - Cheng Dong
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
| | - Shuhong Yi
- Liver Transplantation Center, the Third Affiliated Hospital, Sun Yat-sen University, 510000 Guangzhou, China
| | - Yanwei Jia
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
- Faculty of Science and Technology-ECE, University of Macau, Macau SAR, China
- Cancer Center, Faculty of Health Sciences, University of Macau, Macau SAR, China
| | - Pui-In Mak
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
- Faculty of Science and Technology-ECE, University of Macau, Macau SAR, China
| | - Chu-Xia Deng
- Cancer Center, Faculty of Health Sciences, University of Macau, Macau SAR, China
| | - Rui P. Martins
- State-Key Laboratory of Analog and Mixed-Signal VLSI, Institute of Microelectronics, University of Macau, Macau SAR, China
- Faculty of Science and Technology-ECE, University of Macau, Macau SAR, China
- on leave from Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
24
|
Choudhary D, Mossa A, Jadhav M, Cecconi C. Bio-Molecular Applications of Recent Developments in Optical Tweezers. Biomolecules 2019; 9:E23. [PMID: 30641944 PMCID: PMC6359149 DOI: 10.3390/biom9010023] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 01/02/2019] [Accepted: 01/02/2019] [Indexed: 12/17/2022] Open
Abstract
In the past three decades, the ability to optically manipulate biomolecules has spurred a new era of medical and biophysical research. Optical tweezers (OT) have enabled experimenters to trap, sort, and probe cells, as well as discern the structural dynamics of proteins and nucleic acids at single molecule level. The steady improvement in OT's resolving power has progressively pushed the envelope of their applications; there are, however, some inherent limitations that are prompting researchers to look for alternatives to the conventional techniques. To begin with, OT are restricted by their one-dimensional approach, which makes it difficult to conjure an exhaustive three-dimensional picture of biological systems. The high-intensity trapping laser can damage biological samples, a fact that restricts the feasibility of in vivo applications. Finally, direct manipulation of biological matter at nanometer scale remains a significant challenge for conventional OT. A significant amount of literature has been dedicated in the last 10 years to address the aforementioned shortcomings. Innovations in laser technology and advances in various other spheres of applied physics have been capitalized upon to evolve the next generation OT systems. In this review, we elucidate a few of these developments, with particular focus on their biological applications. The manipulation of nanoscopic objects has been achieved by means of plasmonic optical tweezers (POT), which utilize localized surface plasmons to generate optical traps with enhanced trapping potential, and photonic crystal optical tweezers (PhC OT), which attain the same goal by employing different photonic crystal geometries. Femtosecond optical tweezers (fs OT), constructed by replacing the continuous wave (cw) laser source with a femtosecond laser, promise to greatly reduce the damage to living samples. Finally, one way to transcend the one-dimensional nature of the data gained by OT is to couple them to the other large family of single molecule tools, i.e., fluorescence-based imaging techniques. We discuss the distinct advantages of the aforementioned techniques as well as the alternative experimental perspective they provide in comparison to conventional OT.
Collapse
Affiliation(s)
- Dhawal Choudhary
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, 41125 Modena, Italy.
- Center S3, CNR Institute Nanoscience, Via Campi 213/A, 41125 Modena, Italy.
| | - Alessandro Mossa
- Istituto Statale di Istruzione Superiore "Leonardo da Vinci", Via del Terzolle 91, 50127 Firenze, Italy.
- Istituto Nazionale di Fisica Nucleare, Sezione di Firenze, Via Giovanni Sansone 1, 50019 Sesto Fiorentino, Italy.
| | - Milind Jadhav
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, 41125 Modena, Italy.
| | - Ciro Cecconi
- Department of Physics, Informatics and Mathematics, University of Modena and Reggio Emilia, 41125 Modena, Italy.
- Center S3, CNR Institute Nanoscience, Via Campi 213/A, 41125 Modena, Italy.
| |
Collapse
|
25
|
Dalili A, Samiei E, Hoorfar M. A review of sorting, separation and isolation of cells and microbeads for biomedical applications: microfluidic approaches. Analyst 2019; 144:87-113. [DOI: 10.1039/c8an01061g] [Citation(s) in RCA: 145] [Impact Index Per Article: 29.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
We have reviewed the microfluidic approaches for cell/particle isolation and sorting, and extensively explained the mechanism behind each method.
Collapse
Affiliation(s)
- Arash Dalili
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| | - Ehsan Samiei
- University of Victoria
- Department of Mechanical Engineering
- Victoria
- Canada
| | - Mina Hoorfar
- The University of British
- School of Engineering
- Kelowna
- Canada V1 V 1 V7
| |
Collapse
|
26
|
Killian JL, Inman JT, Wang MD. High-Performance Image-Based Measurements of Biological Forces and Interactions in a Dual Optical Trap. ACS NANO 2018; 12:11963-11974. [PMID: 30457331 PMCID: PMC6857636 DOI: 10.1021/acsnano.8b03679] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Optical traps enable the nanoscale manipulation of individual biomolecules while measuring molecular forces and lengths. This ability relies on the sensitive detection of optically trapped particles, typically accomplished using laser-based interferometric methods. Recently, image-based particle tracking techniques have garnered increased interest as a potential alternative to laser-based detection; however, successful integration of image-based methods into optical trapping instruments for biophysical applications and force measurements has remained elusive. Here, we develop a camera-based detection platform that enables accurate and precise measurements of biological forces and interactions in a dual optical trap. In demonstration, we stretch and unzip DNA molecules while measuring the relative distances of trapped particles from their trapping centers with sub-nanometer accuracy and precision. We then use the DNA unzipping technique to localize bound proteins with sub-base-pair precision, revealing how thermal DNA "breathing" fluctuations allow an unzipping fork to detect and respond to the presence of a protein bound downstream. This work advances the capabilities of image tracking in optical traps, providing a state-of-the-art detection method that is accessible, highly flexible, and broadly compatible with diverse experimental substrates and other nanometric techniques.
Collapse
Affiliation(s)
- Jessica L. Killian
- Physics Department & LASSP, Cornell University, Ithaca, NY 14853, USA
- Howard Hughes Medical Institute, Cornell University, Ithaca, NY 14853, USA
| | - James T. Inman
- Physics Department & LASSP, Cornell University, Ithaca, NY 14853, USA
- Howard Hughes Medical Institute, Cornell University, Ithaca, NY 14853, USA
| | - Michelle D. Wang
- Physics Department & LASSP, Cornell University, Ithaca, NY 14853, USA
- Howard Hughes Medical Institute, Cornell University, Ithaca, NY 14853, USA
| |
Collapse
|
27
|
Keloth A, Anderson O, Risbridger D, Paterson L. Single Cell Isolation Using Optical Tweezers. MICROMACHINES 2018; 9:mi9090434. [PMID: 30424367 PMCID: PMC6187562 DOI: 10.3390/mi9090434] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2018] [Revised: 08/01/2018] [Accepted: 08/23/2018] [Indexed: 12/31/2022]
Abstract
Optical tweezers offer a non-contact method for selecting single cells and translocating them from one microenvironment to another. We have characterized the optical tweezing of yeast S. cerevisiae and can manipulate single cells at 0.41 ± 0.06 mm/s using a 26.8 ± 0.1 mW from a 785 nm diode laser. We have fabricated and tested three cell isolation devices; a micropipette, a PDMS chip and a laser machined fused silica chip and we have isolated yeast, single bacteria and cyanobacteria cells. The most effective isolation was achieved in PDMS chips, where single yeast cells were grown and observed for 18 h without contamination. The duration of budding in S. cerevisiae was not affected by the laser parameters used, but the time from tweezing until the first budding event began increased with increasing laser energy (laser power × time). Yeast cells tweezed using 25.0 ± 0.1 mW for 1 min were viable after isolation. We have constructed a micro-consortium of yeast cells, and a co-culture of yeast and bacteria, using optical tweezers in combination with the PDMS network of channels and isolation chambers, which may impact on both industrial biotechnology and understanding pathogen dynamics.
Collapse
Affiliation(s)
- Anusha Keloth
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot Watt University, Edinburgh EH14 4AS, UK.
| | - Owen Anderson
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot Watt University, Edinburgh EH14 4AS, UK.
| | - Donald Risbridger
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot Watt University, Edinburgh EH14 4AS, UK.
| | - Lynn Paterson
- Institute of Biological Chemistry, Biophysics and Bioengineering, School of Engineering and Physical Sciences, Heriot Watt University, Edinburgh EH14 4AS, UK.
| |
Collapse
|
28
|
Atajanov A, Zhbanov A, Yang S. Sorting and manipulation of biological cells and the prospects for using optical forces. MICRO AND NANO SYSTEMS LETTERS 2018. [DOI: 10.1186/s40486-018-0064-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
29
|
Paiè P, Zandrini T, Vázquez RM, Osellame R, Bragheri F. Particle Manipulation by Optical Forces in Microfluidic Devices. MICROMACHINES 2018; 9:E200. [PMID: 30424133 PMCID: PMC6187572 DOI: 10.3390/mi9050200] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Revised: 04/18/2018] [Accepted: 04/20/2018] [Indexed: 01/09/2023]
Abstract
Since the pioneering work of Ashkin and coworkers, back in 1970, optical manipulation gained an increasing interest among the scientific community. Indeed, the advantages and the possibilities of this technique are unsubtle, allowing for the manipulation of small particles with a broad spectrum of dimensions (nanometers to micrometers size), with no physical contact and without affecting the sample viability. Thus, optical manipulation rapidly found a large set of applications in different fields, such as cell biology, biophysics, and genetics. Moreover, large benefits followed the combination of optical manipulation and microfluidic channels, adding to optical manipulation the advantages of microfluidics, such as a continuous sample replacement and therefore high throughput and automatic sample processing. In this work, we will discuss the state of the art of these optofluidic devices, where optical manipulation is used in combination with microfluidic devices. We will distinguish on the optical method implemented and three main categories will be presented and explored: (i) a single highly focused beam used to manipulate the sample, (ii) one or more diverging beams imping on the sample, or (iii) evanescent wave based manipulation.
Collapse
Affiliation(s)
- Petra Paiè
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Tommaso Zandrini
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
- Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Rebeca Martínez Vázquez
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Roberto Osellame
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| | - Francesca Bragheri
- Istituto di Fotonica e Nanotecnlogie IFN-CNR, Piazza Leonardo da Vinci 32, Milano 20133, Italy.
| |
Collapse
|
30
|
Abstract
A three-dimensional (3D) tissue model has significant advantages over the conventional two-dimensional (2D) model. A 3D model mimics the relevant in-vivo physiological conditions, allowing a cell culture to serve as an effective tool for drug discovery, tissue engineering, and the investigation of disease pathology. The present reviews highlight the recent advances and the development of microfluidics based methods for the generation of cell spheroids. The paper emphasizes on the application of microfluidic technology for tissue engineering including the formation of multicellular spheroids (MCS). Further, the paper discusses the recent technical advances in the integration of microfluidic devices for MCS-based high-throughput drug screening. The review compares the various microfluidic techniques and finally provides a perspective for the future opportunities in this research area.
Collapse
|
31
|
|
32
|
Meineke G, Hermans M, Klos J, Lenenbach A, Noll R. A microfluidic opto-caloric switch for sorting of particles by using 3D-hydrodynamic focusing based on SLE fabrication capabilities. LAB ON A CHIP 2016; 16:820-8. [PMID: 26862603 DOI: 10.1039/c5lc01478f] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
In a miniaturised flow switch fluid flows are controlled by reducing the local viscosity via absorption of laser radiation. Through this, the local flow rates are increased to switch the outlet port of a fluid flow carrying the analyte. The microfluidic chip is fabricated using Selective Laser-Induced Etching (SLE). SLE allows novel 3D-hydrodynamic focusing, realising circular shaped channel cross-sections and adapting interaction volume geometries to the profile of the laser radiation for optimised absorption. The performance of the switch is validated experimentally with a dyed analyte and video image processing. The ability to sort particles like cells is demonstrated at 8 Hz using polystyrene beads having a diameter of 8 μm.
Collapse
Affiliation(s)
- G Meineke
- Fraunhofer Institute for Laser Technology ILT, Steinbachstraße 15, 52074 Aachen, Germany.
| | - M Hermans
- LightFab GmbH, Steinbachstraße 15, 52074 Aachen, Germany.
| | - J Klos
- Fraunhofer Institute for Laser Technology ILT, Steinbachstraße 15, 52074 Aachen, Germany.
| | - A Lenenbach
- Fraunhofer Institute for Laser Technology ILT, Steinbachstraße 15, 52074 Aachen, Germany.
| | - R Noll
- Fraunhofer Institute for Laser Technology ILT, Steinbachstraße 15, 52074 Aachen, Germany.
| |
Collapse
|
33
|
Baranski M, Bargiel S, Passilly N, Gorecki C, Jia C, Frömel J, Wiemer M. Micro-optical design of a three-dimensional microlens scanner for vertically integrated micro-opto-electro-mechanical systems. APPLIED OPTICS 2015; 54:6924-6934. [PMID: 26368111 DOI: 10.1364/ao.54.006924] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper presents the optical design of a miniature 3D scanning system, which is fully compatible with the vertical integration technology of micro-opto-electro-mechanical systems (MOEMS). The constraints related to this integration strategy are considered, resulting in a simple three-element micro-optical setup based on an afocal scanning microlens doublet and a focusing microlens, which is tolerant to axial position inaccuracy. The 3D scanning is achieved by axial and lateral displacement of microlenses of the scanning doublet, realized by micro-electro-mechanical systems microactuators (the transmission scanning approach). Optical scanning performance of the system is determined analytically by use of the extended ray transfer matrix method, leading to two different optical configurations, relying either on a ball lens or plano-convex microlenses. The presented system is aimed to be a core component of miniature MOEMS-based optical devices, which require a 3D optical scanning function, e.g., miniature imaging systems (confocal or optical coherence microscopes) or optical tweezers.
Collapse
|
34
|
Abstract
Traditionally, cell analysis has focused on using molecular biomarkers for basic research, cell preparation, and clinical diagnostics; however, new microtechnologies are enabling evaluation of the mechanical properties of cells at throughputs that make them amenable to widespread use. We review the current understanding of how the mechanical characteristics of cells relate to underlying molecular and architectural changes, describe how these changes evolve with cell-state and disease processes, and propose promising biomedical applications that will be facilitated by the increased throughput of mechanical testing: from diagnosing cancer and monitoring immune states to preparing cells for regenerative medicine. We provide background about techniques that laid the groundwork for the quantitative understanding of cell mechanics and discuss current efforts to develop robust techniques for rapid analysis that aim to implement mechanophenotyping as a routine tool in biomedicine. Looking forward, we describe additional milestones that will facilitate broad adoption, as well as new directions not only in mechanically assessing cells but also in perturbing them to passively engineer cell state.
Collapse
Affiliation(s)
- Eric M Darling
- Center for Biomedical Engineering.,Department of Molecular Pharmacology, Physiology, and Biotechnology.,Department of Orthopaedics, and.,School of Engineering, Brown University, Providence, Rhode Island 02912;
| | - Dino Di Carlo
- Department of Bioengineering.,California NanoSystems Institute, and.,Jonsson Comprehensive Cancer Center, University of California, Los Angeles, California 90095;
| |
Collapse
|
35
|
Optical Nanofiber Integrated into Optical Tweezers for In Situ Fiber Probing and Optical Binding Studies. PHOTONICS 2015. [DOI: 10.3390/photonics2030795] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
36
|
Kumar PT, Vriens K, Cornaglia M, Gijs M, Kokalj T, Thevissen K, Geeraerd A, Cammue BPA, Puers R, Lammertyn J. Digital microfluidics for time-resolved cytotoxicity studies on single non-adherent yeast cells. LAB ON A CHIP 2015; 15:1852-1860. [PMID: 25710603 DOI: 10.1039/c4lc01469c] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Single cell analysis (SCA) has gained increased popularity for elucidating cellular heterogeneity at genomic, proteomic and cellular levels. Flow cytometry is considered as one of the most widely used techniques to characterize single cell responses; however, its inability to analyse cells with spatio-temporal resolution poses a major drawback. Here, we introduce a digital microfluidic (DMF) platform as a useful tool for conducting studies on isolated yeast cells in a high-throughput fashion. The reported system exhibits (i) a microwell array for trapping single non-adherent cells by shuttling a cell-containing droplet over the array, and allows (ii) implementation of high-throughput cytotoxicity assays with enhanced spatio-temporal resolution. The system was tested for five different concentrations of the antifungal drug Amphotericin B, and the cell responses were monitored over time by time lapse fluorescence microscopy. The DMF platform was validated by bulk experiments, which mimicked the DMF experimental design. A correlation analysis revealed that the results obtained on the DMF platform are not significantly different from those obtained in bulk; hence, the DMF platform can be used as a tool to perform SCA on non-adherent cells, with spatio-temporal resolution. In addition, no external forces, other than the physical forces generated by moving the droplet, were used to capture single cells, thereby avoiding cell damage. As such, the information on cellular behaviour during treatment could be obtained for every single cell over time making this platform noteworthy in the field of SCA.
Collapse
Affiliation(s)
- P T Kumar
- BIOSYST-MEBIOS, KU Leuven, Willem de Croylaan 42, Heverlee, Belgium.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
He L, Kniss A, San-Miguel A, Rouse T, Kemp ML, Lu H. An automated programmable platform enabling multiplex dynamic stimuli delivery and cellular response monitoring for high-throughput suspension single-cell signaling studies. LAB ON A CHIP 2015; 15:1497-507. [PMID: 25609410 PMCID: PMC4362087 DOI: 10.1039/c4lc01070a] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Cell signaling events are orchestrated by dynamic external biochemical cues. By rapidly perturbing cells with dynamic inputs and examining the output from these systems, one could study the structure and dynamic properties of a cellular signaling network. Conventional experimental techniques limit the implementation of these systematic approaches due to the lack of sophistication in manipulating individual cells and the fluid microenvironment around them; existing microfluidic technologies thus far are mainly targeting adherent cells. In this paper we present an automated platform to interrogate suspension cells with dynamic stimuli while simultaneously monitoring cellular responses in a high-throughput manner at single-cell resolution. We demonstrate the use of this platform in an experiment to measure Jurkat T cells in response to distinct dynamic patterns of stimuli; we find cells exhibit highly heterogeneous responses under each stimulation condition. More interestingly, these cells act as low-pass filters, only entrained to the low frequency stimulus signals. We also demonstrate that this platform can be easily programmed to actively generate arbitrary dynamic signals. We envision our platform to be useful in other contexts to study cellular signaling dynamics, which may be difficult using conventional experimental methods.
Collapse
Affiliation(s)
- Luye He
- School of Chemical & Biomolecular Engineering , Georgia Institute of Technology , 311 Ferst Dr. NW , Atlanta , GA , USA 30332-0100 .
| | - Ariel Kniss
- Department of Biomedical Engineering , Georgia Institute of Technology and Emory University , 313 Ferst Dr. NW , Atlanta , GA , USA 30332-0535
| | - Adriana San-Miguel
- School of Chemical & Biomolecular Engineering , Georgia Institute of Technology , 311 Ferst Dr. NW , Atlanta , GA , USA 30332-0100 .
| | - Tel Rouse
- School of Chemical & Biomolecular Engineering , Georgia Institute of Technology , 311 Ferst Dr. NW , Atlanta , GA , USA 30332-0100 .
| | - Melissa L. Kemp
- Department of Biomedical Engineering , Georgia Institute of Technology and Emory University , 313 Ferst Dr. NW , Atlanta , GA , USA 30332-0535
| | - Hang Lu
- School of Chemical & Biomolecular Engineering , Georgia Institute of Technology , 311 Ferst Dr. NW , Atlanta , GA , USA 30332-0100 .
| |
Collapse
|
38
|
Guan A, Shenoy A, Smith R, Li Z. Streamline based design guideline for deterministic microfluidic hydrodynamic single cell traps. BIOMICROFLUIDICS 2015; 9:024103. [PMID: 25825618 PMCID: PMC4352164 DOI: 10.1063/1.4914469] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2014] [Accepted: 02/27/2015] [Indexed: 05/03/2023]
Abstract
A prerequisite for single cell study is the capture and isolation of individual cells. In microfluidic devices, cell capture is often achieved by means of trapping. While many microfluidic trapping techniques exist, hydrodynamic methods are particularly attractive due to their simplicity and scalability. However, current design guidelines for single cell hydrodynamic traps predominantly rely on flow resistance manipulation or qualitative streamline analysis without considering the target particle size. This lack of quantitative design criteria from first principles often leads to non-optimal probabilistic trapping. In this work, we describe an analytical design guideline for deterministic single cell hydrodynamic trapping through the optimization of streamline distributions under laminar flow with cell size as a key parameter. Using this guideline, we demonstrate an example design which can achieve 100% capture efficiency for a given particle size. Finite element modelling was used to determine the design parameters necessary for optimal trapping. The simulation results were subsequently confirmed with on-chip microbead and white blood cell trapping experiments.
Collapse
Affiliation(s)
- Allan Guan
- Department of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA
| | - Aditi Shenoy
- Department of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA
| | - Richard Smith
- Department of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA
| | - Zhenyu Li
- Department of Biomedical Engineering, The George Washington University , Washington, District of Columbia 20052, USA
| |
Collapse
|
39
|
|
40
|
Ye T, Li H, Lam KY. Two-dimensional numerical modeling for separation of deformable cells using dielectrophoresis. Electrophoresis 2014; 36:378-85. [DOI: 10.1002/elps.201400251] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2014] [Revised: 05/19/2014] [Accepted: 06/09/2014] [Indexed: 11/07/2022]
Affiliation(s)
- Ting Ye
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore Singapore
| | - Hua Li
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore Singapore
| | - K. Y. Lam
- School of Mechanical and Aerospace Engineering; Nanyang Technological University; Singapore Singapore
| |
Collapse
|
41
|
Millen J, Deesuwan T, Barker P, Anders J. Nanoscale temperature measurements using non-equilibrium Brownian dynamics of a levitated nanosphere. NATURE NANOTECHNOLOGY 2014; 9:425-9. [PMID: 24793558 DOI: 10.1038/nnano.2014.82] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2013] [Accepted: 03/21/2014] [Indexed: 05/27/2023]
Abstract
Einstein realized that the fluctuations of a Brownian particle can be used to ascertain the properties of its environment. A large number of experiments have since exploited the Brownian motion of colloidal particles for studies of dissipative processes, providing insight into soft matter physics and leading to applications from energy harvesting to medical imaging. Here, we use heated optically levitated nanospheres to investigate the non-equilibrium properties of the gas surrounding them. Analysing the sphere's Brownian motion allows us to determine the temperature of the centre-of-mass motion of the sphere, its surface temperature and the heated gas temperature in two spatial dimensions. We observe asymmetric heating of the sphere and gas, with temperatures reaching the melting point of the material. This method offers opportunities for accurate temperature measurements with spatial resolution on the nanoscale, and provides a means for testing non-equilibrium thermodynamics.
Collapse
Affiliation(s)
- J Millen
- Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - T Deesuwan
- 1] Department of Physics, Imperial College London, Prince Consort Road, London SW7 2AZ, UK [2] Department of Physics and Astronomy, University of Exeter, Stocker Road, Exeter EX4 4QL, UK
| | - P Barker
- Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK
| | - J Anders
- 1] Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT, UK [2] Department of Physics and Astronomy, University of Exeter, Stocker Road, Exeter EX4 4QL, UK
| |
Collapse
|
42
|
Shi X, Gao W, Wang J, Chao SH, Zhang W, Meldrum DR. Measuring gene expression in single bacterial cells: recent advances in methods and micro-devices. Crit Rev Biotechnol 2014; 35:448-60. [DOI: 10.3109/07388551.2014.899556] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
43
|
Nikel PI, Silva-Rocha R, Benedetti I, de Lorenzo V. The private life of environmental bacteria: pollutant biodegradation at the single cell level. Environ Microbiol 2014; 16:628-42. [DOI: 10.1111/1462-2920.12360] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 11/23/2013] [Accepted: 12/10/2013] [Indexed: 11/28/2022]
Affiliation(s)
- Pablo Iván Nikel
- Systems and Synthetic Biology Program; Centro Nacional de Biotecnología (CNB-CSIC); Madrid 28049 Spain
| | - Rafael Silva-Rocha
- Systems and Synthetic Biology Program; Centro Nacional de Biotecnología (CNB-CSIC); Madrid 28049 Spain
| | - Ilaria Benedetti
- Systems and Synthetic Biology Program; Centro Nacional de Biotecnología (CNB-CSIC); Madrid 28049 Spain
| | - Víctor de Lorenzo
- Systems and Synthetic Biology Program; Centro Nacional de Biotecnología (CNB-CSIC); Madrid 28049 Spain
| |
Collapse
|
44
|
Chrimes AF, Khoshmanesh K, Stoddart PR, Mitchell A, Kalantar-Zadeh K. Microfluidics and Raman microscopy: current applications and future challenges. Chem Soc Rev 2014; 42:5880-906. [PMID: 23624774 DOI: 10.1039/c3cs35515b] [Citation(s) in RCA: 123] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Raman microscopy systems are becoming increasingly widespread and accessible for characterising chemical species. Microfluidic systems are also progressively finding their way into real world applications. Therefore, it is anticipated that the integration of Raman systems with microfluidics will become increasingly attractive and practical. This review aims to provide an overview of Raman microscopy-microfluidics integrated systems for researchers who are actively interested in utilising these tools. The fundamental principles and application strengths of Raman microscopy are discussed in the context of microfluidics. Various configurations of microfluidics that incorporate Raman microscopy methods are presented, with applications highlighted. Data analysis methods are discussed, with a focus on assisting the interpretation of Raman-microfluidics data from complex samples. Finally, possible future directions of Raman-microfluidic systems are presented.
Collapse
Affiliation(s)
- Adam F Chrimes
- School of Electrical and Computer Engineering, RMIT University, 124 LaTrobe St, Melbourne, Australia.
| | | | | | | | | |
Collapse
|
45
|
Tengfei Z, Chaohui W, Dong N, Weitao J, Yongsheng S, Lei Y, Bangdao C, Hongzhong L, Yucheng D. Exploitation of surface acoustic waves to drive nanoparticle concentration within an electrification-dependent droplet. RSC Adv 2014. [DOI: 10.1039/c4ra07090a] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
When SSAW propagates into microlitre droplets, two forces act on the particles. We obtain patterned particles by changing the DEP force.
Collapse
Affiliation(s)
- Zheng Tengfei
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Wang Chaohui
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Niu Dong
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Jiang Weitao
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Shi Yongsheng
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Yin Lei
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Chen Bangdao
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Liu Hongzhong
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| | - Ding Yucheng
- State Key Laboratory for Manufacturing Systems Engineering
- Xi'an Jiaotong University
- Xi'an 710049, People's Republic of China
| |
Collapse
|
46
|
|
47
|
Zhou J, Giridhar PV, Kasper S, Papautsky I. Modulation of aspect ratio for complete separation in an inertial microfluidic channel. LAB ON A CHIP 2013; 13:1919-29. [PMID: 23529341 DOI: 10.1039/c3lc50101a] [Citation(s) in RCA: 90] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Inertial microfluidics has been attracting considerable interest in recent years due to immensely promising applications in cell separations and sorting. Despite the intense attention, the moderate efficiencies and low purity of the reported devices have hindered their widespread acceptance. In this work, we report on a simple inertial microfluidic system with high efficiency (>99%) and purity (>90%). Our system builds on the concept of two-stage inertial migration which permits precise prediction of particle or cell position within the microchannel. Our design manipulates the inertial equilibrium positions by modulating channel aspect ratio to achieve a complete separation. Here, we successfully demonstrate a complete separation of particles and isolation of rare cells in blood spiked with human prostate epithelial tumor (HPET) cells. Based on the planar structure, large separation spacing and predictable focusing, we envision promising applications and easy integration of our system with existing lab-on-a-chip systems for cell separations.
Collapse
Affiliation(s)
- Jian Zhou
- BioMicroSystems Laboratory, School of Electronic and Computing Systems, University of Cincinnati, Cincinnati, OH, USA
| | | | | | | |
Collapse
|
48
|
Cell signaling experiments driven by optical manipulation. Int J Mol Sci 2013; 14:8963-84. [PMID: 23698758 PMCID: PMC3676767 DOI: 10.3390/ijms14058963] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Revised: 04/08/2013] [Accepted: 04/14/2013] [Indexed: 01/09/2023] Open
Abstract
Cell signaling involves complex transduction mechanisms in which information released by nearby cells or extracellular cues are transmitted to the cell, regulating fundamental cellular activities. Understanding such mechanisms requires cell stimulation with precise control of low numbers of active molecules at high spatial and temporal resolution under physiological conditions. Optical manipulation techniques, such as optical tweezing, mechanical stress probing or nano-ablation, allow handling of probes and sub-cellular elements with nanometric and millisecond resolution. PicoNewton forces, such as those involved in cell motility or intracellular activity, can be measured with femtoNewton sensitivity while controlling the biochemical environment. Recent technical achievements in optical manipulation have new potentials, such as exploring the actions of individual molecules within living cells. Here, we review the progress in optical manipulation techniques for single-cell experiments, with a focus on force probing, cell mechanical stimulation and the local delivery of active molecules using optically manipulated micro-vectors and laser dissection.
Collapse
|
49
|
Abstract
This review surveys selected methods of manufacture and applications of microdevices-miniaturized functional devices capable of handling cell and tissue cultures or producing particles-and discusses their potential relevance to nanomedicine. Many characteristics of microdevices such as miniaturization, increased throughput, and the ability to mimic organ-specific microenvironments are promising for the rapid, low-cost evaluation of the efficacy and toxicity of nanomaterials. Their potential to accurately reproduce the physiological environments that occur in vivo could reduce dependence on animal models in pharmacological testing. Technologies in microfabrications and microfluidics are widely applicable for nanomaterial synthesis and for the development of diagnostic devices. Although the use of microdevices in nanomedicine is still in its infancy, these technologies show promise for enhancing fundamental and applied research in nanomedicine.
Collapse
Affiliation(s)
- Michinao Hashimoto
- Laboratory for Biomaterials and Drug Delivery, Department of Anesthesiology, Division of Critical Care Medicine, Children's Hospital Boston, Harvard Medical School, Boston, MA 02115, USA
| | | | | |
Collapse
|
50
|
Bisceglia E, Cubizolles M, Mallard F, Vinet F, Français O, Le Pioufle B. Micro-organism extraction from biological samples using DEP forces enhanced by osmotic shock. LAB ON A CHIP 2013; 13:901-9. [PMID: 23306307 DOI: 10.1039/c2lc41128h] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
On the road towards efficient diagnostics of infectious diseases, sample preparation is considered as the key step and remains a real technical challenge. Finding new methods for extraction of micro-organisms from a complex biological sample remains a major challenge prior to pathogen detection and analysis. This paper reports a new technique for capturing and isolating micro-organisms from a complex sample. To achieve the segregation of pathogens and blood cells, dielectrophoretic forces applied to bioparticles previously subjected to an osmotic shock are successfully implemented within a dedicated microfluidic device. Our device involves an electrode array of interdigitated electrodes, coated with an insulating layer, to minimize electrochemical reactions with the electrolyte and to enable long-time use. The electric field intensity inside the device is optimized, considering the insulating layer, for a given frequency bandwidth, enabling the separation of bioparticles by dielectrophoretic forces. Our predictions are based on analytical models, consistent with numerical simulations (using COMSOL Multiphysics) and correlated to experimental results. The method and device have been shown to extract different types of micro-organisms spiked in a blood cell sample. We strongly believe that this new separation approach may open the way towards a simple device for pathogen extraction from blood and more generally complex samples, with potential advantages of genericness and simplicity.
Collapse
Affiliation(s)
- Emilie Bisceglia
- Department of microTechnology for Biology and Health, CEA LETI-Minatec, Grenoble, France
| | | | | | | | | | | |
Collapse
|