1
|
Pape A, Ayala-Cabrera JF, Stappert F, Uteschil F, Thom C, Yoshioka S, Terui Y, Schmitz OJ. Development of an Ultrasonic Nebulization System for an Inverse Low Temperature Plasma Ionization Source. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024. [PMID: 39327939 DOI: 10.1021/jasms.4c00259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/28/2024]
Abstract
An effective nebulization and evaporation of a liquid sample, like in liquid chromatography, mass spectrometry (LC-MS) couplings, is an essential requirement for the ionization of analyte molecules in the gas phase by, for example, atmospheric pressure chemical ionization (APCI) or the novel low temperature plasma (LTP)-based ion source. These LTP-based ion sources have recently gained interest in the field of atmospheric pressure ion sources, as they can cover a wide range of polarity and molecular mass. They can be used in combination with separation techniques like liquid chromatography or used as an ambient ion source. However, commercial nebulizer systems are of course not constructed to fit to home-built LTP-based ion sources, and this was one incentive to develop a new nebulization system. Instead of an atmospheric pressure chemical ionization (APCI) nebulizer, two commercial nebulizers were disassembled and remodeled to be used as nebulizing systems in an LC-MS setup using an LTP-based ion source. Based on these results, a novel nebulizer system was subsequently developed. To further improve the degree of ionization, cones to focus the LC eluent spray on the plasma region, heating applications, and auxiliary nitrogen gas for dispersion of the solvent droplets were implemented. The LOD that could be calculated via the rule of three resulted in an average of 2.0 μg/L for the APCI-nebulizer and 41 μg/L for the USN. Both could be reduced to 1.4 and 18 μg/L, respectively, by using a TPI-configuration instead of an iLTP. The linearity was equally good for both types of nebulization devices. The final nebulizer could also be operated with a high water content and flow rates higher than those of the two previous ones, indicating an important improvement step.
Collapse
Affiliation(s)
- Alexandra Pape
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
- Teaching and Research Center for Separation, University Duisburg-Essen, 45141 Essen, Germany
| | - Juan F Ayala-Cabrera
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
- Teaching and Research Center for Separation, University Duisburg-Essen, 45141 Essen, Germany
| | - Florian Stappert
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
- Teaching and Research Center for Separation, University Duisburg-Essen, 45141 Essen, Germany
| | - Florian Uteschil
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
- Teaching and Research Center for Separation, University Duisburg-Essen, 45141 Essen, Germany
| | - Cedric Thom
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
| | - Shinji Yoshioka
- Hitachi High-Tech Corporation, Healthcare Business Group Diagnostic System Business, 882, Ichige, Hitachinaka-shi, Ibaraki-ken 312-8504, Japan
| | - Yasushi Terui
- Hitachi High-Tech Solutions Corporation, Mito Div. OT Solution Div., 500, Miyu-cho, Mito-shi, Ibaraki-ken 319-0316, Japan
| | - Oliver J Schmitz
- University Duisburg-Essen, Applied Analytical Chemistry, 45141 Essen, Germany
- Teaching and Research Center for Separation, University Duisburg-Essen, 45141 Essen, Germany
| |
Collapse
|
2
|
Agarwalla S, Singh SK, Duraiswamy S. A traveling surface acoustic wave-based micropiezoactuator: A tool for additive- and label-free cell lysis. BIOMICROFLUIDICS 2024; 18:054104. [PMID: 39280194 PMCID: PMC11392560 DOI: 10.1063/5.0209663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 08/25/2024] [Indexed: 09/18/2024]
Abstract
We propose a traveling surface acoustic wave (TSAW)-based microfluidic method for cell lysis that enables lysis of any biological entity, without the need for additional additives. Lysis of cells in the sample solution flowing through a poly (dimethyl siloxane) microchannel is enabled by the interaction of cells with TSAWs propagated from gold interdigitated transducers (IDTs) patterned onto a LiNbO3 piezoelectric substrate, onto which the microchannel was also bonded. Numerical simulations to determine the wave propagation intensities with varying parameters including IDT design, supply voltage, and distance of the channel from the IDT were performed. Experiments were then used to validate the simulations and the best lysis parameters were used to maximize the nucleic acid/protein extraction efficiency (>95%) within few seconds. A comparative analysis of our method with traditional chemical, physical and thermal, as well as the current microfluidic methods for lysis demonstrates the superiority of our method. Our lysis strategy can hence be used independently and/or integrated with other nucleic acid-based technologies or point-of-care devices for the lysis of any pathogen (Gram positives and negatives), eukaryotic cells, and tissues at low voltage (3 V) and frequency (33.17 MHz), without the use of amplifiers.
Collapse
Affiliation(s)
- Sushama Agarwalla
- Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| | - Sunil Kumar Singh
- Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| | - Suhanya Duraiswamy
- Indian Institute of Technology Hyderabad, Kandi, Sangareddy, Telangana 502285, India
| |
Collapse
|
3
|
Xu M, Vidler C, Wang J, Chen X, Pan Z, Harley WS, Lee PVS, Collins DJ. Micro-Acoustic Holograms for Detachable Microfluidic Devices. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2307529. [PMID: 38174594 DOI: 10.1002/smll.202307529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 11/24/2023] [Indexed: 01/05/2024]
Abstract
Acoustic microfluidic devices have advantages for diagnostic applications, therapeutic solutions, and fundamental research due to their contactless operation, simple design, and biocompatibility. However, most acoustofluidic approaches are limited to forming simple and fixed acoustic patterns, or have limited resolution. In this study,a detachable microfluidic device is demonstrated employing miniature acoustic holograms to create reconfigurable, flexible, and high-resolution acoustic fields in microfluidic channels, where the introduction of a solid coupling layer makes these holograms easy to fabricate and integrate. The application of this method to generate flexible acoustic fields, including shapes, characters, and arbitrarily rotated patterns, within microfluidic channels, is demonstrated.
Collapse
Affiliation(s)
- Mingxin Xu
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Callum Vidler
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Jizhen Wang
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Xi Chen
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Zijian Pan
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - William S Harley
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
| | - Peter V S Lee
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
- Graeme Clarke Institute, University of Melbourne, Parkville, Victoria, 3052, Australia
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, 3010, Australia
- Graeme Clarke Institute, University of Melbourne, Parkville, Victoria, 3052, Australia
| |
Collapse
|
4
|
Liu H, Zhou Z, Lou L. Wireless Temperature Measurement for Curved Surfaces Based on AlN Surface Acoustic Wave Resonators. MICROMACHINES 2024; 15:562. [PMID: 38793135 PMCID: PMC11123193 DOI: 10.3390/mi15050562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 04/21/2024] [Accepted: 04/23/2024] [Indexed: 05/26/2024]
Abstract
In this paper, we propose a novel method for temperature measurement using surface acoustic wave (SAW) temperature sensors on curved or irregular surfaces. We integrate SAW resonators onto flexible printed circuit boards (FPCBs) to ensure better conformity of the temperature sensor with the surface of the object under test. Compared to traditional rigid PCBs, FPCBs offer greater dynamic flexibility, lighter weight, and thinner thickness, which make them an ideal choice for making SAW devices working for temperature measurements under curved surfaces. We design a temperature sensor array consisting of three devices with different operating frequencies to measure the temperature at multiple points on the surface of the object. To distinguish between different target points in the sensor array, each sensor operates at a different frequency, and the operating frequency bands do not overlap. This differentiation is achieved using Frequency Division Multiple Access (FDMA) technology. Experimental results indicate that the frequency temperature coefficients of these sensors are -30.248 ppm/°C, -30.195 ppm/°C, and -30.115 ppm/°C, respectively. In addition, the sensor array enables wireless communication via antenna and transceiver circuits. This innovation heralds enhanced adaptability and applicability for SAW temperature sensor applications.
Collapse
Affiliation(s)
- Huali Liu
- School of Microelectronics, Shanghai University, Shanghai 201800, China; (H.L.); (Z.Z.)
- The Shanghai Industrial µTechnology Research Institute, Shanghai 201899, China
| | - Zhixin Zhou
- School of Microelectronics, Shanghai University, Shanghai 201800, China; (H.L.); (Z.Z.)
- The Shanghai Industrial µTechnology Research Institute, Shanghai 201899, China
| | - Liang Lou
- School of Microelectronics, Shanghai University, Shanghai 201800, China; (H.L.); (Z.Z.)
- The Shanghai Industrial µTechnology Research Institute, Shanghai 201899, China
| |
Collapse
|
5
|
Mandal D, Bovender T, Geil RD, Banerjee S. Surface Acoustic Waves (SAW) Sensors: Tone-Burst Sensing for Lab-on-a-Chip Devices. SENSORS (BASEL, SWITZERLAND) 2024; 24:644. [PMID: 38276335 PMCID: PMC10819011 DOI: 10.3390/s24020644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Revised: 01/13/2024] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
The article presents the design concept of a surface acoustic wave (SAW)-based lab-on-a-chip sensor with multifrequency and multidirectional sensitivity. The conventional SAW sensors use delay lines that suffer from multiple signal losses such as insertion, reflection, transmission losses, etc. Most delay lines are designed to transmit and receive continuous signal at a fixed frequency. Thus, the delay lines are limited to only a few features, like frequency shift and change in wave velocity, during the signal analysis. These facts lead to limited sensitivity and a lack of opportunity to utilize the multi-directional variability of the sensing platform at different frequencies. Motivated by these facts, a guided wave sensing platform that utilizes simultaneous tone burst-based excitation in multiple directions is proposed in this article. The design incorporates a five-count tone burst signal for the omnidirectional actuation. This helps the acquisition of sensitive long part of the coda wave (CW) signals from multiple directions, which is hypothesized to enhance sensitivity through improved signal analysis. In this article, the design methodology and implementation of unique tone burst interdigitated electrodes (TB-IDT) are presented. Sensing using TB-IDT enables accessing multiple frequencies simultaneously. This results in a wider frequency spectrum and allows better scope for the detection of different target analytes. The novel design process utilized guided wave analysis of the substrate, and selective directional focused interdigitated electrodes (F-IDT) were implemented. The article demonstrates computational simulation along with experimental results with validation of multifrequency and multidirectional sensing capability.
Collapse
Affiliation(s)
- Debdyuti Mandal
- Integrated Material Assessment and Predictive Simulation (iMAPS) Laboratory, Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA; (D.M.); (T.B.)
| | - Tally Bovender
- Integrated Material Assessment and Predictive Simulation (iMAPS) Laboratory, Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA; (D.M.); (T.B.)
| | - Robert D. Geil
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA;
| | - Sourav Banerjee
- Integrated Material Assessment and Predictive Simulation (iMAPS) Laboratory, Department of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA; (D.M.); (T.B.)
| |
Collapse
|
6
|
Dong C, Tian R, Qu H, Tan H, Chen G, Guan H, Yin Z. Anchoring Pt Particles onto Mesoporousized ZnO Holey Cubes for Triethylamine Detection with Multifaceted Superiorities. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300756. [PMID: 37078834 DOI: 10.1002/smll.202300756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 03/23/2023] [Indexed: 05/03/2023]
Abstract
Designing sensing materials with integrating unique spatial structures, functional units, and surface activity is vital to achieve high-performance gas sensor toward triethylamine (TEA) detection. Herein, a simple spontaneous dissolution is used with subsequent thermal decomposition strategy to fabricate mesoporousized ZnO holey cubes. The squaric acid is crucial to coordinate Zn2+ to form a cubic shape (ZnO-0) and then tailor the inner part to open a holey cube with simultaneously mesoporousizing the left cubic body (ZnO-72). To enhance the sensing performance, the mesoporous ZnO holey cubes have been functionalized with catalytic Pt nanoparticles, which deliver superior performances including high response, low detection limit, and fast response and recovery time. Notably, the response of Pt/ZnO-72 towards 200 ppm TEA is up to 535, which is much higher than those of 43 and 224 for pristine ZnO-0 and ZnO-72. A synergistic mechanism combining the intrinsic merits of ZnO, its unique mesoporous holey cubic structure, the oxygen vacancies, and the catalytic sensitization effect of Pt has been proposed for the significant enhancement in TEA sensing. Our work provides an effective facile approach to fabricate an advanced micro-nano architecture with manipulating its spatial structure, functional units, and active mesoporous surface for promising TEA gas sensors.
Collapse
Affiliation(s)
- Chengjun Dong
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
- Research School of Chemistry, Australian National University, Canberra, Australian Capital Territory, 2601, Australia
| | - Ruonan Tian
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
| | - Honglong Qu
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
| | - Huai Tan
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
| | - Gang Chen
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
| | - Hongtao Guan
- School of Materials and Energy, Yunnan University, Kunming, 650091, P. R. China
| | - Zongyou Yin
- Research School of Chemistry, Australian National University, Canberra, Australian Capital Territory, 2601, Australia
| |
Collapse
|
7
|
Qin X, Chen X, Yang Q, Yang L, Liu Y, Zhang C, Wei X, Wang W. Analysis of Acousto-Optic Phenomenon in SAW Acoustofluidic Chip and Its Application in Light Refocusing. MICROMACHINES 2023; 14:mi14050943. [PMID: 37241567 DOI: 10.3390/mi14050943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 04/23/2023] [Accepted: 04/25/2023] [Indexed: 05/28/2023]
Abstract
This paper describes and analyzes a common acousto-optic phenomenon in surface acoustic wave (SAW) microfluidic chips and accomplishes some imaging experiments based on these analyses. This phenomenon in acoustofluidic chips includes the appearance of bright and dark stripes and image distortion. This article analyzes the three-dimensional acoustic pressure field and refractive index field distribution induced by focused acoustic fields and completes an analysis of the light path in an uneven refractive index medium. Based on the analysis of microfluidic devices, a SAW device based on a solid medium is further proposed. This MEMS SAW device can refocus the light beam and adjust the sharpness of the micrograph. The focal length can be controlled by changing the voltage. Moreover, the chip is also proven to be capable of forming a refractive index field in scattering media, such as tissue phantom and pig subcutaneous fat layer. This chip has the potential to be used as a planar microscale optical component that is easy to integrate and further optimize and provides a new concept about tunable imaging devices that can be attached directly to the skin or tissue.
Collapse
Affiliation(s)
- Xianming Qin
- School of Mechano-Electronic Engineering, Xidian University, Xi'an 710071, China
- CityU-Xidian Joint Laboratory of Micro/Nano-Manufacturing, Xi'an 710071, China
| | - Xuan Chen
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Qiqi Yang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Lei Yang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Yan Liu
- School of Mechano-Electronic Engineering, Xidian University, Xi'an 710071, China
- CityU-Xidian Joint Laboratory of Micro/Nano-Manufacturing, Xi'an 710071, China
| | - Chuanyu Zhang
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xueyong Wei
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Weidong Wang
- School of Mechano-Electronic Engineering, Xidian University, Xi'an 710071, China
- CityU-Xidian Joint Laboratory of Micro/Nano-Manufacturing, Xi'an 710071, China
| |
Collapse
|
8
|
Kordzadeh-Kermani V, Dartoomi H, Azizi M, Ashrafizadeh SN, Madadelahi M. Investigating the Performance of the Multi-Lobed Leaf-Shaped Oscillatory Obstacles in Micromixers Using Bulk Acoustic Waves (BAW): Mixing and Chemical Reaction. MICROMACHINES 2023; 14:795. [PMID: 37421028 DOI: 10.3390/mi14040795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 03/27/2023] [Accepted: 03/29/2023] [Indexed: 07/09/2023]
Abstract
Proper mixing in microfluidic devices has been a concern since the early development stages. Acoustic micromixers (active micromixers) attract significant attention due to their high efficiency and ease of implementation. Finding the optimal geometries, structures, and characteristics of acoustic micromixers is still a challenging issue. In this study, we considered leaf-shaped obstacle(s) having a multi-lobed structure as the oscillatory part(s) of acoustic micromixers in a Y-junction microchannel. Four different types of leaf-shaped oscillatory obstacles, including 1, 2, 3, and 4-lobed structures, were defined, and their mixing performance for two fluid streams was evaluated numerically. The geometrical parameters of the leaf-shaped obstacle(s), including the number of lobes, lobes' length, lobes' inside angle, and lobes' pitch angle, were analyzed, and their optimum operational values were discovered. Additionally, the effects of the placement of oscillatory obstacles in three configurations, i.e., at the junction center, on the side walls, and both, on the mixing performance were evaluated. It was found that by increasing the number and length of lobes, the mixing efficiency improved. Furthermore, the effect of the operational parameters, such as inlet velocity, frequency, and intensity of acoustic waves, was examined on mixing efficiency. Meanwhile, the occurrence of a bimolecular reaction in the microchannel was analyzed at different reaction rates. It was proven that the reaction rate has a prominent effect at higher inlet velocities.
Collapse
Affiliation(s)
- Vahid Kordzadeh-Kermani
- Research Lab for Advanced Separation Processes, Department of Chemical Engineering, Iran University of Science and Technology, Tehran 16846-13114, Iran
| | - Hossein Dartoomi
- Research Lab for Advanced Separation Processes, Department of Chemical Engineering, Iran University of Science and Technology, Tehran 16846-13114, Iran
| | - Mina Azizi
- Department of Electronics, South Tehran Branch Azad University, Tehran 15847-15414, Iran
| | - Seyed Nezameddin Ashrafizadeh
- Research Lab for Advanced Separation Processes, Department of Chemical Engineering, Iran University of Science and Technology, Tehran 16846-13114, Iran
| | - Masoud Madadelahi
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111, Iran
- School of Engineering and Sciences, Tecnologico de Monterrey, Monterrey 64849, NL, Mexico
| |
Collapse
|
9
|
Nampoothiri KN, Nath A, Satpathi NS, Sen AK. Deicing of Sessile Droplets Using Surface Acoustic Waves. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:3934-3941. [PMID: 36883239 DOI: 10.1021/acs.langmuir.2c03208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Deicing has significant relevance in various applications such as transportation, energy production, and telecommunication. The use of surface acoustic waves (SAWs) is an attractive option for deicing as it offers several advantages such as localized heating, in situ control, low power, and system integration for highly efficient deicing. Here, we report an understanding of the dynamics of deicing of microlitre volume water droplets (1 to 30 μL) exposed to low power (0.3 W) SAW actuation using an interdigitated electrode on a piezoelectric (LiNbO3) substrate. We study the time variation of the volume of liquid water from the onset of SAW actuation to complete deicing, which takes 2.5 to 35 s depending on the droplet volume. The deicing phenomenon is attributed to acoustothermal heating which is found to be greatly influenced by the loss of ice adhesion with the substrate and the acoustic streaming within the liquid water. Acoustothermal heating inside the droplet is characterized by the temperature distribution inside the droplet using infrared thermography, and acoustic streaming is observed using dye-based optical microscopy. A rapid enhancement in deicing is observed upon the detachment of ice from the substrate and the onset of acoustic streaming, marked by a sudden increase in the liquid water volume, droplet temperature, and heat transfer coefficient. The deicing time is found to increase linearly with droplet volume as observed from experiments and further verified using a theoretical model. Our study provides an improved understanding of the recently introduced SAW-based deicing technique that may open up the avenue for a suitable alternative to standard deicing protocols.
Collapse
Affiliation(s)
- K N Nampoothiri
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamilnadu 600036, India
- Department of Mechanical Engineering, Amrita School of Engineering, Amrita Vishwa Vidyapeetham, Chennai, Tamilnadu 601103, India
| | - A Nath
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamilnadu 600036, India
| | - N S Satpathi
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamilnadu 600036, India
| | - A K Sen
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras, Chennai, Tamilnadu 600036, India
- Micro Nano Bio-Fluidics Group, Indian Institute of Technology Madras, Chennai, Tamilnadu 600036, India
| |
Collapse
|
10
|
Sabaté Del Río J, Ro J, Yoon H, Park TE, Cho YK. Integrated technologies for continuous monitoring of organs-on-chips: Current challenges and potential solutions. Biosens Bioelectron 2023; 224:115057. [PMID: 36640548 DOI: 10.1016/j.bios.2022.115057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 12/29/2022] [Accepted: 12/30/2022] [Indexed: 01/03/2023]
Abstract
Organs-on-chips (OoCs) are biomimetic in vitro systems based on microfluidic cell cultures that recapitulate the in vivo physicochemical microenvironments and the physiologies and key functional units of specific human organs. These systems are versatile and can be customized to investigate organ-specific physiology, pathology, or pharmacology. They are more physiologically relevant than traditional two-dimensional cultures, can potentially replace the animal models or reduce the use of these models, and represent a unique opportunity for the development of personalized medicine when combined with human induced pluripotent stem cells. Continuous monitoring of important quality parameters of OoCs via a label-free, non-destructive, reliable, high-throughput, and multiplex method is critical for assessing the conditions of these systems and generating relevant analytical data; moreover, elaboration of quality predictive models is required for clinical trials of OoCs. Presently, these analytical data are obtained by manual or automatic sampling and analyzed using single-point, off-chip traditional methods. In this review, we describe recent efforts to integrate biosensing technologies into OoCs for monitoring the physiologies, functions, and physicochemical microenvironments of OoCs. Furthermore, we present potential alternative solutions to current challenges and future directions for the application of artificial intelligence in the development of OoCs and cyber-physical systems. These "smart" OoCs can learn and make autonomous decisions for process optimization, self-regulation, and data analysis.
Collapse
Affiliation(s)
- Jonathan Sabaté Del Río
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan, 44919, Republic of Korea
| | - Jooyoung Ro
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan, 44919, Republic of Korea; Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea
| | - Heejeong Yoon
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea
| | - Tae-Eun Park
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea.
| | - Yoon-Kyoung Cho
- Center for Soft and Living Matter, Institute for Basic Science (IBS), Ulsan, 44919, Republic of Korea; Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea.
| |
Collapse
|
11
|
Rasouli R, Villegas KM, Tabrizian M. Acoustofluidics - changing paradigm in tissue engineering, therapeutics development, and biosensing. LAB ON A CHIP 2023; 23:1300-1338. [PMID: 36806847 DOI: 10.1039/d2lc00439a] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
For more than 70 years, acoustic waves have been used to screen, diagnose, and treat patients in hundreds of medical devices. The biocompatible nature of acoustic waves, their non-invasive and contactless operation, and their compatibility with wide visualization techniques are just a few of the many features that lead to the clinical success of sound-powered devices. The development of microelectromechanical systems and fabrication technologies in the past two decades reignited the spark of acoustics in the discovery of unique microscale bio applications. Acoustofluidics, the combination of acoustic waves and fluid mechanics in the nano and micro-realm, allowed researchers to access high-resolution and controllable manipulation and sensing tools for particle separation, isolation and enrichment, patterning of cells and bioparticles, fluid handling, and point of care biosensing strategies. This versatility and attractiveness of acoustofluidics have led to the rapid expansion of platforms and methods, making it also challenging for users to select the best acoustic technology. Depending on the setup, acoustic devices can offer a diverse level of biocompatibility, throughput, versatility, and sensitivity, where each of these considerations can become the design priority based on the application. In this paper, we aim to overview the recent advancements of acoustofluidics in the multifaceted fields of regenerative medicine, therapeutic development, and diagnosis and provide researchers with the necessary information needed to choose the best-suited acoustic technology for their application. Moreover, the effect of acoustofluidic systems on phenotypic behavior of living organisms are investigated. The review starts with a brief explanation of acoustofluidic principles, the different working mechanisms, and the advantages or challenges of commonly used platforms based on the state-of-the-art design features of acoustofluidic technologies. Finally, we present an outlook of potential trends, the areas to be explored, and the challenges that need to be overcome in developing acoustofluidic platforms that can echo the clinical success of conventional ultrasound-based devices.
Collapse
Affiliation(s)
- Reza Rasouli
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
| | - Karina Martinez Villegas
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
| | - Maryam Tabrizian
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
12
|
Parolo C, Idili A, Heikenfeld J, Plaxco KW. Conformational-switch biosensors as novel tools to support continuous, real-time molecular monitoring in lab-on-a-chip devices. LAB ON A CHIP 2023; 23:1339-1348. [PMID: 36655710 PMCID: PMC10799767 DOI: 10.1039/d2lc00716a] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Recent years have seen continued expansion of the functionality of lab on a chip (LOC) devices. Indeed LOCs now provide scientists and developers with useful and versatile platforms across a myriad of chemical and biological applications. The field still fails, however, to integrate an often important element of bench-top analytics: real-time molecular measurements that can be used to "guide" a chemical response. Here we describe the analytical techniques that could provide LOCs with such real-time molecular monitoring capabilities. It appears to us that, among the approaches that are general (i.e., that are independent of the reactive or optical properties of their targets), sensing strategies relying on binding-induced conformational change of bioreceptors are most likely to succeed in such applications.
Collapse
Affiliation(s)
- Claudio Parolo
- Barcelona Institute for Global Health, Hospital Clínic Universitat de Barcelona, 08036, Barcelona, Spain
| | - Andrea Idili
- Department of Chemical Science and Technologies, University of Rome, Tor Vergata, 00133 Rome, Italy
| | - Jason Heikenfeld
- Novel Devices Laboratory, University of Cincinnati, Cincinnati, Ohio, USA
| | - Kevin W Plaxco
- Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California, USA.
- Interdepartmental Program in Biomolecular Science and Engineering, University of California Santa Barbara, Santa Barbara, California, USA
| |
Collapse
|
13
|
Ba Hashwan SS, Khir MHM, Nawi IM, Ahmad MR, Hanif M, Zahoor F, Al-Douri Y, Algamili AS, Bature UI, Alabsi SS, Sabbea MOB, Junaid M. A review of piezoelectric MEMS sensors and actuators for gas detection application. NANOSCALE RESEARCH LETTERS 2023; 18:25. [PMID: 36847870 DOI: 10.1186/s11671-023-03779-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 01/25/2023] [Indexed: 05/24/2023]
Abstract
Piezoelectric microelectromechanical system (piezo-MEMS)-based mass sensors including the piezoelectric microcantilevers, surface acoustic waves (SAW), quartz crystal microbalance (QCM), piezoelectric micromachined ultrasonic transducer (PMUT), and film bulk acoustic wave resonators (FBAR) are highlighted as suitable candidates for highly sensitive gas detection application. This paper presents the piezo-MEMS gas sensors' characteristics such as their miniaturized structure, the capability of integration with readout circuit, and fabrication feasibility using multiuser technologies. The development of the piezoelectric MEMS gas sensors is investigated for the application of low-level concentration gas molecules detection. In this work, the various types of gas sensors based on piezoelectricity are investigated extensively including their operating principle, besides their material parameters as well as the critical design parameters, the device structures, and their sensing materials including the polymers, carbon, metal-organic framework, and graphene.
Collapse
Affiliation(s)
- Saeed S Ba Hashwan
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia.
| | - Mohd Haris Md Khir
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Illani Mohd Nawi
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mohamad Radzi Ahmad
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mehwish Hanif
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Furqan Zahoor
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Y Al-Douri
- Nanotechnology and Catalysis Research Centre (NANOCAT), University of Malaya, Kuala Lumpur, Malaysia
- Department of Mechanical Engineering, Faculty of Engineering, Piri Reis University, Eflatun Sk. No: 8, 34940, Tuzla, Istanbul, Turkey
- Department of Applied Science and Astronomy, College of Sciences, University of Sharjah, Sharjah, United Arab Emirates
| | - Abdullah Saleh Algamili
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Usman Isyaku Bature
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Sami Sultan Alabsi
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
| | - Mohammed O Ba Sabbea
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada
| | - Muhammad Junaid
- Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Malaysia
- Department of Electronic Engineering, Balochistan University of Information Technology, Engineering and Management Sciences, Quetta, 87300, Pakistan
| |
Collapse
|
14
|
Amir S, Arathi A, Reshma S, Mohanan PV. Microfluidic devices for the detection of disease-specific proteins and other macromolecules, disease modelling and drug development: A review. Int J Biol Macromol 2023; 235:123784. [PMID: 36822284 DOI: 10.1016/j.ijbiomac.2023.123784] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 02/15/2023] [Accepted: 02/16/2023] [Indexed: 02/25/2023]
Abstract
Microfluidics is a revolutionary technology that has promising applications in the biomedical field.Integrating microfluidic technology with the traditional assays unravels the innumerable possibilities for translational biomedical research. Microfluidics has the potential to build up a novel platform for diagnosis and therapy through precise manipulation of fluids and enhanced throughput functions. The developments in microfluidics-based devices for diagnostics have evolved in the last decade and have been established for their rapid, effective, accurate and economic advantages. The efficiency and sensitivity of such devices to detect disease-specific macromolecules like proteins and nucleic acids have made crucial impacts in disease diagnosis. The disease modelling using microfluidic systems provides a more prominent replication of the in vivo microenvironment and can be a better alternative for the existing disease models. These models can replicate critical microphysiology like the dynamic microenvironment, cellular interactions, and biophysical and biochemical cues. Microfluidics also provides a promising system for high throughput drug screening and delivery applications. However, microfluidics-based diagnostics still encounter related challenges in the reliability, real-time monitoring and reproducibility that circumvents this technology from being impacted in the healthcare industry. This review highlights the recent microfluidics developments for modelling and diagnosing common diseases, including cancer, neurological, cardiovascular, respiratory and autoimmune disorders, and its applications in drug development.
Collapse
Affiliation(s)
- S Amir
- Toxicology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (Govt. of India), Poojapura, Trivandrum 695 012, Kerala, India
| | - A Arathi
- Toxicology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (Govt. of India), Poojapura, Trivandrum 695 012, Kerala, India
| | - S Reshma
- Toxicology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (Govt. of India), Poojapura, Trivandrum 695 012, Kerala, India
| | - P V Mohanan
- Toxicology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (Govt. of India), Poojapura, Trivandrum 695 012, Kerala, India.
| |
Collapse
|
15
|
Wang Y, Wang S, Li L, Zou Y, Liu B, Fang X. Microfluidics‐based molecular profiling of tumor‐derived exosomes for liquid biopsy. VIEW 2023. [DOI: 10.1002/viw.20220048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Affiliation(s)
- Yuqing Wang
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| | - Shurong Wang
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| | - Lanting Li
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| | - Yan Zou
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| | - Baohong Liu
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| | - Xiaoni Fang
- School of Pharmacy Shanghai Stomatological Hospital Department of Chemistry Fudan University Shanghai China
| |
Collapse
|
16
|
Taziev R, Atuchin V. Analysis of SAW Temperature Properties in KTiOPO 4 Single Crystal. MATERIALS (BASEL, SWITZERLAND) 2022; 16:69. [PMID: 36614406 PMCID: PMC9821228 DOI: 10.3390/ma16010069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 12/19/2022] [Accepted: 12/19/2022] [Indexed: 06/17/2023]
Abstract
The surface acoustic wave (SAW) properties of potassium titanyl phosphate (KTiOPO4, KTP) single crystal were evaluated by numerical methods. The phase velocity, electromechanical coupling coefficient, power flow deflection angle, and temperature coefficient of delay (TCD) were determined for different crystal cuts of KTP. It was shown that SAW has the electromechanical coupling coefficient of 0.59% and the TCD of 62 ppm/°C on the Z-cut and wave propagation direction along the crystal X + 70°-axis. For the Z-cut and wave propagation direction along the X-axis, the pseudo-surface wave (PSAW) is characterized by the coupling coefficient of 0.46% and the TCD value of 57 ppm/°C. The Bleustein-Gulyaev (BG) wave has the TCD value of 35 ppm/°C and 41 ppm/°C on the Y- and X-cuts of KTP, respectively.
Collapse
Affiliation(s)
- Rinat Taziev
- Laboratory of Optical Materials and Structures, Institute of Semiconductor Physics, SB RAS, 630090 Novosibirsk, Russia
| | - Victor Atuchin
- Laboratory of Optical Materials and Structures, Institute of Semiconductor Physics, SB RAS, 630090 Novosibirsk, Russia
- Research and Development Department, Kemerovo State University, 650000 Kemerovo, Russia
- Department of Industrial Machinery Design, Novosibirsk State Technical University, 630073 Novosibirsk, Russia
- R&D Center “Advanced Electronic Technologies”, Tomsk State University, 634034 Tomsk, Russia
| |
Collapse
|
17
|
Ng RC, El Sachat A, Cespedes F, Poblet M, Madiot G, Jaramillo-Fernandez J, Florez O, Xiao P, Sledzinska M, Sotomayor-Torres CM, Chavez-Angel E. Excitation and detection of acoustic phonons in nanoscale systems. NANOSCALE 2022; 14:13428-13451. [PMID: 36082529 PMCID: PMC9520674 DOI: 10.1039/d2nr04100f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 08/15/2022] [Indexed: 06/15/2023]
Abstract
Phonons play a key role in the physical properties of materials, and have long been a topic of study in physics. While the effects of phonons had historically been considered to be a hindrance, modern research has shown that phonons can be exploited due to their ability to couple to other excitations and consequently affect the thermal, dielectric, and electronic properties of solid state systems, greatly motivating the engineering of phononic structures. Advances in nanofabrication have allowed for structuring and phonon confinement even down to the nanoscale, drastically changing material properties. Despite developments in fabricating such nanoscale devices, the proper manipulation and characterization of phonons continues to be challenging. However, a fundamental understanding of these processes could enable the realization of key applications in diverse fields such as topological phononics, information technologies, sensing, and quantum electrodynamics, especially when integrated with existing electronic and photonic devices. Here, we highlight seven of the available methods for the excitation and detection of acoustic phonons and vibrations in solid materials, as well as advantages, disadvantages, and additional considerations related to their application. We then provide perspectives towards open challenges in nanophononics and how the additional understanding granted by these techniques could serve to enable the next generation of phononic technological applications.
Collapse
Affiliation(s)
- Ryan C Ng
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | | | - Francisco Cespedes
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
- Departamento de Física, Universidad Autónoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Martin Poblet
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | - Guilhem Madiot
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | - Juliana Jaramillo-Fernandez
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | - Omar Florez
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
- Departamento de Física, Universidad Autónoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Peng Xiao
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
- Departamento de Física, Universidad Autónoma de Barcelona, Bellaterra, 08193 Barcelona, Spain
| | - Marianna Sledzinska
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| | - Clivia M Sotomayor-Torres
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
- ICREA, Passeig Lluis Companys 23, 08010 Barcelona, Spain
| | - Emigdio Chavez-Angel
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain.
| |
Collapse
|
18
|
Stoukatch S, Dupont F, Redouté JM. Device Processing Challenges for Miniaturized Sensing Systems Targeting Biological Fluids. BIOMEDICAL MATERIALS & DEVICES 2022. [PMCID: PMC9510362 DOI: 10.1007/s44174-022-00034-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 09/02/2022] [Indexed: 09/29/2023]
Abstract
This article presents a review of device processing technologies used in the fabrication of biomedical systems, and highlights the requirements of advanced manufacturing technology. We focus on biomedical systems that perform diagnostics of fluidic specimens, with analytes that are in the liquid phase. In the introduction, we define biomedical systems as well as their versatile applications and the essential current trends. The paper gives an overview of the most important biomolecules that typically must be detected or analyzed in several applications. The paper is structured as follows. First, the conventional architecture and construction of a biosensing system is introduced. We provide an overview of the most common biosensing methods that are currently used for the detection of biomolecules and its analysis. We present an overview of reported biochips, and explain the technology of biofunctionalization and detection principles, including their corresponding advantages and disadvantages. Next, we introduce microfluidics as a method for delivery of the specimen to the biochip sensing area. A special focus lies on material requirements and on manufacturing technology for fabricating microfluidic systems, both for niche and mass-scale production segments. We formulate requirements and constraints for integrating the biochips and microfluidic systems. The possible impacts of the conventional microassembly techniques and processing methods on the entire biomedical system and its specific parts are also described. On that basis, we explain the need for alternative microassembly technologies to enable the integration of biochips and microfluidic systems into fully functional systems.
Collapse
Affiliation(s)
- S. Stoukatch
- Microsys Lab, Department of Electrical Engineering and Computer Science, Liege University, Seraing, Belgium
| | - F. Dupont
- Microsys Lab, Department of Electrical Engineering and Computer Science, Liege University, Seraing, Belgium
| | - J.-M. Redouté
- Microsys Lab, Department of Electrical Engineering and Computer Science, Liege University, Seraing, Belgium
| |
Collapse
|
19
|
Tian L, Shen Q, Chang H. A novel progressive wave gyroscope based on acousto-optic effects. MICROSYSTEMS & NANOENGINEERING 2022; 8:95. [PMID: 36060524 PMCID: PMC9437048 DOI: 10.1038/s41378-022-00429-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 05/29/2022] [Accepted: 06/22/2022] [Indexed: 06/15/2023]
Abstract
We propose and numerically investigate a brand-new, high-sensitivity progressive wave gyroscope based on acousto-optic effects for the measurement of rotational angular velocity. Unlike the traditional surface acoustic wave (SAW) gyroscope, which uses shifts in the SAW frequency to characterize the rotational angular velocity, this study uses acousto-optic effects to detect changes in refractive index caused by mechanical strain, measuring the angular velocity by the output optical power intensity of the optical waveguide. The three-dimensional finite element analysis method is utilized to build an SAW excitation model and optical detection model. We show that the sensitivity of the SAW gyroscope is highly dependent upon geometric parameters of the structure and that the mechanical strain induced by the progressive wave of the SAW can be effectively measured by the optical power intensity under the action of external angular velocity. The superiority of the proposed structure is substantiated by its achievement of a theoretical sensitivity of 1.8647 (mW/m2)/(rad/s) and high impact resistance of 220,000 g. By means of normalization, the sensitivity of the proposed structure can be enhanced by four orders of magnitude compared to the traditional SAW gyroscope. The novel structure combines the advantages of both conventional microscale vibrating gyroscopes and optical gyroscopes, providing a powerful solution for performance enhancement of SAW gyroscopes and, thereby, enabling application in the field of inertial devices.
Collapse
Affiliation(s)
- Lu Tian
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospacea, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
| | - Qiang Shen
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospacea, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
| | - Honglong Chang
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospacea, School of Mechanical Engineering, Northwestern Polytechnical University, Xi’an, 710072 China
| |
Collapse
|
20
|
Nampoothiri KN, Satpathi NS, Sen AK. Surface acoustic wave-based generation and transfer of droplets onto wettable substrates. RSC Adv 2022; 12:23400-23410. [PMID: 36090390 PMCID: PMC9382648 DOI: 10.1039/d2ra04089a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 08/09/2022] [Indexed: 11/21/2022] Open
Abstract
Fluid manipulation using surface acoustic waves (SAW) has been utilized as a promising technique in the field of microfluidics due to its numerous advantages, over other active techniques, such as low power requirement, facile fabrication methods, and non-invasive nature. Even though SAW-based generation of micron-sized droplets through atomization has been studied, the role of substrate wettability on the characteristics of the transferred droplets has not been explored to date. Here, we study the generation and effective transfer of micron-sized droplets using SAW onto wettable substrates whose water contact angles vary from 5° to 145°. The characteristics of transferred droplets after impacting the wettable substrates are characterized in terms of the contact line diameter and polydispersity index. A theoretical model is formulated to predict the initial average size of the transferred droplets on the wettable substrates of different contact angles. The variation of polydispersity and number density with contact angle is explained by considering droplet coalescence and bouncing. The relevance of the technique in biological assays is demonstrated by transferring droplets of streptavidin protein samples onto a substrate.
Collapse
Affiliation(s)
| | - Niladri Sekhar Satpathi
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai-600036 India
| | - Ashis Kumar Sen
- Fluid Systems Laboratory, Department of Mechanical Engineering, Indian Institute of Technology Madras Chennai-600036 India
- Micro Nano Bio Fluidics Group, Indian Institute of Technology Madras Chennai-600036 India
| |
Collapse
|
21
|
Cortez-Jugo C, Masoumi S, Chan PPY, Friend J, Yeo L. Nebulization of siRNA for inhalation therapy based on a microfluidic surface acoustic wave platform. ULTRASONICS SONOCHEMISTRY 2022; 88:106088. [PMID: 35797825 PMCID: PMC9263997 DOI: 10.1016/j.ultsonch.2022.106088] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 06/23/2022] [Accepted: 06/28/2022] [Indexed: 05/14/2023]
Abstract
The local delivery of therapeutic small interfering RNA or siRNA to the lungs has the potential to improve the prognosis for patients suffering debilitating lung diseases. Recent advances in materials science have been aimed at addressing delivery challenges including biodistribution, bioavailability and cell internalization, but an equally important challenge to overcome is the development of an inhalation device that can deliver the siRNA effectively to the lung, without degrading the therapeutic itself. Here, we report the nebulization of siRNA, either naked siRNA or complexed with polyethyleneimine (PEI) or a commercial transfection agent, using a miniaturizable acoustomicrofluidic nebulization device. The siRNA solution could be nebulised without significant degradation into an aerosol mist with tunable mean aerodynamic diameters of approximately 3 µm, which is appropriate for deep lung deposition via inhalation. The nebulized siRNA was tested for its stability, as well as its toxicity and gene silencing properties using the mammalian lung carcinoma cell line A549, which demonstrated that the gene silencing capability of siRNA is retained after nebulization. This highlights the potential application of the acoustomicrofluidic device for the delivery of efficacious siRNA via inhalation, either for systemic delivery via the alveolar epithelium or local therapeutic delivery to the lung.
Collapse
Affiliation(s)
- Christina Cortez-Jugo
- Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria 3052, Australia; Melbourne Centre for Nanofabrication, 151 Wellington Road, Clayton, Victoria 3168, Australia.
| | - Sarah Masoumi
- Micro/Nanophysics Research Laboratory, RMIT University, Melbourne, Victoria 3001, Australia
| | - Peggy P Y Chan
- School of Software and Electrical Engineering, Swinburne University, Hawthorn, Victoria 3122, Australia; Melbourne Centre for Nanofabrication, 151 Wellington Road, Clayton, Victoria 3168, Australia
| | - James Friend
- Micro/Nanophysics Research Laboratory, RMIT University, Melbourne, Victoria 3001, Australia; Melbourne Centre for Nanofabrication, 151 Wellington Road, Clayton, Victoria 3168, Australia
| | - Leslie Yeo
- Micro/Nanophysics Research Laboratory, RMIT University, Melbourne, Victoria 3001, Australia.
| |
Collapse
|
22
|
Sensitivity enhancement analysis of frequency tuned-SAW resonator with temperature for sensor applications. SENSING AND BIO-SENSING RESEARCH 2022. [DOI: 10.1016/j.sbsr.2022.100509] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
23
|
Grabka M, Witkiewicz Z, Jasek K, Piwowarski K. Acoustic Wave Sensors for Detection of Blister Chemical Warfare Agents and Their Simulants. SENSORS 2022; 22:s22155607. [PMID: 35957163 PMCID: PMC9371173 DOI: 10.3390/s22155607] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 07/15/2022] [Accepted: 07/20/2022] [Indexed: 11/16/2022]
Abstract
On-site detection and initial identification of chemical warfare agents (CWAs) remain difficult despite the many available devices designed for this type of analysis. Devices using well-established analytical techniques such as ion mobility spectrometry, gas chromatography coupled with mass spectrometry, or flame photometry, in addition to unquestionable advantages, also have some limitations (complexity, high unit cost, lack of selectivity). One of the emerging techniques of CWA detection is based on acoustic wave sensors, among which surface acoustic wave (SAW) devices and quartz crystal microbalances (QCM) are of particular importance. These devices allow for the construction of undemanding and affordable gas sensors whose selectivity, sensitivity, and other metrological parameters can be tailored by application of particular coating material. This review article presents the current state of knowledge and achievements in the field of SAW and QCM-based gas sensors used for the detection of blister agents as well as simulants of these substances. The scope of the review covers the detection of blister agents and their simulants only, as in the available literature no similar paper was found, in contrast to the detection of nerve agents. The article includes description of the principles of operation of acoustic wave sensors, a critical review of individual studies and solutions, and discusses development prospects of this analytical technique in the field of blister agent detection.
Collapse
|
24
|
Adampourezare M, Hasanzadeh M, Seidi F. Microfluidic assisted recognition of miRNAs towards point-of-care diagnosis: Technical and analytical overview towards biosensing of short stranded single non-coding oligonucleotides. Biomed Pharmacother 2022; 153:113365. [PMID: 35785705 DOI: 10.1016/j.biopha.2022.113365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/24/2022] [Accepted: 06/28/2022] [Indexed: 11/02/2022] Open
Abstract
MiRNAs are short stranded single non-coding oligonucleotides that play an important role in regulating gene expression. MiRNAs are stable in RNase enriched environments such as human body fluids and their dysregulation or abnormal abundance in human body fluids as a diagnostic biomarker has been associated with several diseases. Due to the low concentration of miRNAs, it is difficult to detect using interactive methods (ideal detection limit is femtomolar range). However, clinicians lack sensitive and reliable methods for quantifying miRNA. Microfluidic devices integrated with electrochemical, optical (fluorometric, SERs, FRET, colorimetric), electrochemiluminescence and photoelectrochemical signal readout led to development innovative diagnostic device test, can probably overcome the limitations of the traditional methods. In the present review, microfluid methods for the sensitive and selective recognition of miRNA in various biological matrices are surveyed. Also, advantages and limitation of recognition methods on the performance and efficiency of microfluidic based biosensing of miRNAs are critically investigated. Finally, the future perspectives on the diagnosis of disease based on microfluidic analysis of miRNAs are provided.
Collapse
Affiliation(s)
- Mina Adampourezare
- Department of Biology, Faculty of Natural Science, University of Tabriz, Tabriz, Iran; Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Mohammad Hasanzadeh
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Nutrition Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Farzad Seidi
- Jiangsu Co-Innovation Center for Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials, Nanjing Forestry University, Nanjing 210037, China
| |
Collapse
|
25
|
Vyas T, Singh V, Kodgire P, Joshi A. Insights in detection and analysis of organophosphates using organophosphorus acid anhydrolases (OPAA) enzyme-based biosensors. Crit Rev Biotechnol 2022; 43:521-539. [PMID: 35504858 DOI: 10.1080/07388551.2022.2052012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The human population is dependent on agriculture for its food requirements and survival. Several insecticides and pesticides have found their use for improvements in agricultural yields. Organophosphates (OP) are one of the many compounds used as insecticides and pesticides. OPs have also been used to develop G and V-series chemicals which act as highly toxic nerve agents that can severely influence the normal function of the nervous system in all living beings. Thus, OP compounds utilized as insecticides/pesticides and nerve agents are hazardous to the environment, lethal for humans and other non-target animals. To avoid their toxicity, approaches to detect and neutralize them have become essential. A variety of analytical procedures such as electrochemical processes and chromatography methods, namely liquid and gas chromatography, have been employed to detect OPs. Though these techniques are sensitive and highly accurate they suffer from drawbacks, for instance: their bulky nature and expensive instrumentation, the difficulty of operation, long detection times, and they can yield unpredictable results with variable sample complexities. With the advent of several types of biosensors, the assay of OP compounds has become simpler, faster, cost-effective with improved sensitivity, and provides the capability for onsite detection. OP biosensor assays typically utilize several enzymes with the capability to hydrolyze/degrade OP compounds, such as organophosphate hydrolase (OPH) and organophosphate acid hydrolase (OPAA). This review focuses on discussing various aspects of OPAA as biological recognition unit in terms of its: structure, properties, activity enhancement methods, and utilization for developing OPAA-based biosensing technologies for insecticides, pesticides, and nerve agents.
Collapse
Affiliation(s)
- Tanmay Vyas
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, India
| | - Vinay Singh
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, India
| | - Prashant Kodgire
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, India
| | - Abhijeet Joshi
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Indore, India
| |
Collapse
|
26
|
Gouda M, Tadda MA, Zhao Y, Farmanullah F, Chu B, Li X, He Y. Microalgae Bioactive Carbohydrates as a Novel Sustainable and Eco-Friendly Source of Prebiotics: Emerging Health Functionality and Recent Technologies for Extraction and Detection. Front Nutr 2022; 9:806692. [PMID: 35387198 PMCID: PMC8979111 DOI: 10.3389/fnut.2022.806692] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 02/16/2022] [Indexed: 12/16/2022] Open
Abstract
There is a global interest in the novel consumption, nutritional trends, and the market of new prebiotic sources and their potential functional impacts. Commercially available nutritional supplements based on microalgae that are approved to be edible by FDA, like Arthrospira platensis (Cyanobacteria) and Chlorella vulgaris (Chlorophyta) become widely attractive. Microalgae are rich in carbohydrates, proteins, and polyunsaturated fatty acids that have high bioactivity. Recently, scientists are studying the microalgae polysaccharides (PS) or their derivatives (as dietary fibers) for their potential action as a novel prebiotic source for functional foods. Besides, the microalgae prebiotic polysaccharides are used for medication due to their antioxidant, anticancer, and antihypertensive bioactivities. This review provides an overview of microalgae prebiotics and other macromolecules' health benefits. The phytochemistry of various species as alternative future sources of novel polysaccharides were mentioned. The application as well as the production constraints and multidisciplinary approaches for evaluating microalgae phytochemistry were discussed. Additionally, the association between this potential of combining techniques like spectroscopic, chromatographic, and electrochemical analyses for microalgae sensation and analysis novelty compared to the chemical methods was emphasized.
Collapse
Affiliation(s)
- Mostafa Gouda
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Department of Nutrition and Food Science, National Research Centre, Giza, Egypt
| | - Musa A. Tadda
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Department of Agricultural and Environmental Engineering, Faculty of Engineering, Bayero University, Kano, Nigeria
| | - Yinglei Zhao
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
- Institute of Agricultural Equipment, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - F. Farmanullah
- Faculty of Veterinary and Animal Sciences, National Center for Livestock Breeding Genetics and Genomics LUAWMS, Uthal, Pakistan
| | - Bingquan Chu
- School of Biological and Chemical Engineering, Zhejiang University of Science and Technology, Hangzhou, China
| | - Xiaoli Li
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
| | - Yong He
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
| |
Collapse
|
27
|
Rabus D, Lotthammer F, Degret J, Arapan L, Palmino F, Friedt JM, Cherioux F. Degradation of Sub-Micrometer Sensitive Polymer Layers of Acoustic Sensors Exposed to Chlorpyrifos Water-Solution. SENSORS (BASEL, SWITZERLAND) 2022; 22:1203. [PMID: 35161948 PMCID: PMC8840410 DOI: 10.3390/s22031203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 01/28/2022] [Accepted: 02/02/2022] [Indexed: 11/20/2022]
Abstract
The detection of organophosphates, a wide class of pesticides, in water-solution has a huge impact in environmental monitoring. Acoustic transducers are used to design passive wireless sensors for the direct detection of pesticides in water-solution by using tailored polymers as sensitive layers. We demonstrate by combining analytical chemistry tools that organophosphate molecules strongly alter polymer layers widely used in acoustic sensors in the presence of water. This chemical degradation can limit the use of these polymers in detection of organophosphates in water-solution.
Collapse
Affiliation(s)
| | | | | | | | | | - Jean-Michel Friedt
- Franche-Comté Électronique Mécanique Thermique et Optique-Sciences et Technologies, Université de Franche-Comté, CNRS, 15B Avenue des Montboucons, CEDEX, F-25030 Besancon, France; (D.R.); (F.L.); (J.D.); (L.A.); (F.P.)
| | - Frédéric Cherioux
- Franche-Comté Électronique Mécanique Thermique et Optique-Sciences et Technologies, Université de Franche-Comté, CNRS, 15B Avenue des Montboucons, CEDEX, F-25030 Besancon, France; (D.R.); (F.L.); (J.D.); (L.A.); (F.P.)
| |
Collapse
|
28
|
Mandal D, Banerjee S. Surface Acoustic Wave (SAW) Sensors: Physics, Materials, and Applications. SENSORS (BASEL, SWITZERLAND) 2022; 22:820. [PMID: 35161565 PMCID: PMC8839725 DOI: 10.3390/s22030820] [Citation(s) in RCA: 61] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Revised: 01/11/2022] [Accepted: 01/13/2022] [Indexed: 12/20/2022]
Abstract
Surface acoustic waves (SAWs) are the guided waves that propagate along the top surface of a material with wave vectors orthogonal to the normal direction to the surface. Based on these waves, SAW sensors are conceptualized by employing piezoelectric crystals where the guided elastodynamic waves are generated through an electromechanical coupling. Electromechanical coupling in both active and passive modes is achieved by integrating interdigitated electrode transducers (IDT) with the piezoelectric crystals. Innovative meta-designs of the periodic IDTs define the functionality and application of SAW sensors. This review article presents the physics of guided surface acoustic waves and the piezoelectric materials used for designing SAW sensors. Then, how the piezoelectric materials and cuts could alter the functionality of the sensors is explained. The article summarizes a few key configurations of the electrodes and respective guidelines for generating different guided wave patterns such that new applications can be foreseen. Finally, the article explores the applications of SAW sensors and their progress in the fields of biomedical, microfluidics, chemical, and mechano-biological applications along with their crucial roles and potential plans for improvements in the long-term future in the field of science and technology.
Collapse
Affiliation(s)
| | - Sourav Banerjee
- Integrated Material Assessment and Predictive Simulation Laboratory, University of South Carolina, Columbia, SC 29208, USA;
| |
Collapse
|
29
|
WANG A, ZHU Y, ZOU L, ZHU H, CAO R, ZHAO G. Combination of machine learning and intelligent sensors in real-time quality control of alcoholic beverages. FOOD SCIENCE AND TECHNOLOGY 2022. [DOI: 10.1590/fst.54622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Affiliation(s)
| | | | | | - Hong ZHU
- Ministry of Agriculture and Rural Affairs, China
| | - Ruge CAO
- Tianjin University of Science and Technology, China
| | | |
Collapse
|
30
|
Rich J, Tian Z, Huang TJ. Sonoporation: Past, Present, and Future. ADVANCED MATERIALS TECHNOLOGIES 2022; 7:2100885. [PMID: 35399914 PMCID: PMC8992730 DOI: 10.1002/admt.202100885] [Citation(s) in RCA: 28] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Indexed: 05/09/2023]
Abstract
A surge of research in intracellular delivery technologies is underway with the increased innovations in cell-based therapies and cell reprogramming. Particularly, physical cell membrane permeabilization techniques are highlighted as the leading technologies because of their unique features, including versatility, independence of cargo properties, and high-throughput delivery that is critical for providing the desired cell quantity for cell-based therapies. Amongst the physical permeabilization methods, sonoporation holds great promise and has been demonstrated for delivering a variety of functional cargos, such as biomolecular drugs, proteins, and plasmids, to various cells including cancer, immune, and stem cells. However, traditional bubble-based sonoporation methods usually require special contrast agents. Bubble-based sonoporation methods also have high chances of inducing irreversible damage to critical cell components, lowering the cell viability, and reducing the effectiveness of delivered cargos. To overcome these limitations, several novel non-bubble-based sonoporation mechanisms are under development. This review will cover both the bubble-based and non-bubble-based sonoporation mechanisms being employed for intracellular delivery, the technologies being investigated to overcome the limitations of traditional platforms, as well as perspectives on the future sonoporation mechanisms, technologies, and applications.
Collapse
Affiliation(s)
- Joseph Rich
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Zhenhua Tian
- Department of Aerospace Engineering, Mississippi State University, Mississippi State, MS, 39762, USA
| | - Tony Jun Huang
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, 27708, USA
| |
Collapse
|
31
|
Yao K, Chen S, Lai SC, Yousry YM. Enabling Distributed Intelligence with Ferroelectric Multifunctionalities. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 9:e2103842. [PMID: 34719870 PMCID: PMC8728856 DOI: 10.1002/advs.202103842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Indexed: 05/05/2023]
Abstract
Distributed intelligence involving a large number of smart sensors and edge computing are highly demanded under the backdrop of increasing cyber-physical interactive applications including internet of things. Here, the progresses on ferroelectric materials and their enabled devices promising energy autonomous sensors and smart systems are reviewed, starting with an analysis on the basic characteristics of ferroelectrics, including high dielectric permittivity, switchable spontaneous polarization, piezoelectric, pyroelectric, and bulk photovoltaic effects. As sensors, ferroelectrics can directly convert the stimuli to signals without requiring external power supply in principle. As energy transducers, ferroelectrics can harvest multiple forms of energy with high reliability and durability. As capacitors, ferroelectrics can directly store electrical charges with high power and ability of pulse-mode signal generation. Nonvolatile memories derived from ferroelectrics are able to realize digital processors and systems with ultralow power consumption, sustainable operation with intermittent power supply, and neuromorphic computing. An emphasis is made on the utilization of the multiple extraordinary functionalities of ferroelectrics to enable material-critical device innovations. The ferroelectric characteristics and synergistic functionality combinations are invaluable for realizing distributed sensors and smart systems with energy autonomy.
Collapse
Affiliation(s)
- Kui Yao
- Institute of Materials Research and EngineeringA*STAR (Agency for Science, Technology and Research)2 Fusionopolis WayInnovis138634Singapore
| | - Shuting Chen
- Institute of Materials Research and EngineeringA*STAR (Agency for Science, Technology and Research)2 Fusionopolis WayInnovis138634Singapore
| | - Szu Cheng Lai
- Institute of Materials Research and EngineeringA*STAR (Agency for Science, Technology and Research)2 Fusionopolis WayInnovis138634Singapore
| | - Yasmin Mohamed Yousry
- Institute of Materials Research and EngineeringA*STAR (Agency for Science, Technology and Research)2 Fusionopolis WayInnovis138634Singapore
| |
Collapse
|
32
|
Han J, Yang F, Hu H, Huang Q, Lei Y, Li M. Thermal Control Design and Packaging for Surface Acoustic Wave Devices in Acoustofluidics. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:386-398. [PMID: 34329161 DOI: 10.1109/tuffc.2021.3101248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
This article presents a thermal control design method for a surface acoustic wave (SAW) device. We designed a heat-dissipation structure and packaging scheme to solve three key issues observed in SAW devices using anisotropic crystals as piezoelectric substrates in acoustofluidics (e.g., lithium niobate): SAW chip cracking caused by thermal stress, SAW chip cracking caused by mismatched thermal expansion coefficients of the packaging materials, and enhancement of the structural strength and stability of the SAW chip. This study establishes the physical model of the designed structure and the relationship between the steady-state working temperature and the physical properties of the material. By comparing these physical properties and numerical calculations, we identified nanosilver adhesive as the most effective bonding material between the SAW chip and the heat sink. In addition to designing and fabricating, we also evaluated our SAW devices experimentally. The results not only confirmed that the abovementioned three key problems were solved but also demonstrated the significant enhancement of the stability of the SAW device.
Collapse
|
33
|
Akther A, Walsh EP, Reineck P, Gibson BC, Ohshima T, Abe H, McColl G, Jenkins NL, Hall LT, Simpson DA, Rezk AR, Yeo LY. Acoustomicrofluidic Concentration and Signal Enhancement of Fluorescent Nanodiamond Sensors. Anal Chem 2021; 93:16133-16141. [PMID: 34813284 DOI: 10.1021/acs.analchem.1c03893] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Diamond nitrogen-vacancy (NV) centers constitute a promising class of quantum nanosensors owing to the unique magneto-optic properties associated with their spin states. The large surface area and photostability of diamond nanoparticles, together with their relatively low synthesis costs, make them a suitable platform for the detection of biologically relevant quantities such as paramagnetic ions and molecules in solution. Nevertheless, their sensing performance in solution is often hampered by poor signal-to-noise ratios and long acquisition times due to distribution inhomogeneities throughout the analyte sample. By concentrating the diamond nanoparticles through an intense microcentrifugation effect in an acoustomicrofluidic device, we show that the resultant dense NV ensembles within the diamond nanoparticles give rise to an order-of-magnitude improvement in the measured acquisition time. The ability to concentrate nanoparticles under surface acoustic wave (SAW) microcentrifugation in a sessile droplet is, in itself, surprising given the well-documented challenge of achieving such an effect for particles below 1 μm in dimension. In addition to a demonstration of their sensing performance, we thus reveal in this work that the reason why the diamond nanoparticles readily concentrate under the SAW-driven recirculatory flow can be attributed to their considerably higher density and hence larger acoustic contrast compared to those for typical particles and cells for which the SAW microcentrifugation flow has been shown to date.
Collapse
Affiliation(s)
- Asma Akther
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Ella P Walsh
- School of Physics, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Philipp Reineck
- ARC Centre of Excellence for Nanoscale BioPhotonics & School of Science, RMIT University, Melbourne, Victoria 3001, Australia
| | - Brant C Gibson
- ARC Centre of Excellence for Nanoscale BioPhotonics & School of Science, RMIT University, Melbourne, Victoria 3001, Australia
| | - Takeshi Ohshima
- National Institutes for Quantum Science and Technology, Takasaki, Gunma 370-1292, Japan
| | - Hiroshi Abe
- National Institutes for Quantum Science and Technology, Takasaki, Gunma 370-1292, Japan
| | - Gawain McColl
- Melbourne Dementia Research Centre, The Florey Institute of Neuroscience and Mental Health, The University of Melbourne Parkville, Victoria 3010, Australia
| | - Nicole L Jenkins
- Melbourne Dementia Research Centre, The Florey Institute of Neuroscience and Mental Health, The University of Melbourne Parkville, Victoria 3010, Australia
| | - Liam T Hall
- School of Chemistry, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - David A Simpson
- School of Physics, The University of Melbourne, Parkville, Victoria 3010, Australia
| | - Amgad R Rezk
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Leslie Y Yeo
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| |
Collapse
|
34
|
State of the Art in Crystallization of LiNbO 3 and Their Applications. Molecules 2021; 26:molecules26227044. [PMID: 34834135 PMCID: PMC8617696 DOI: 10.3390/molecules26227044] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2021] [Revised: 11/12/2021] [Accepted: 11/16/2021] [Indexed: 11/16/2022] Open
Abstract
Lithium niobate (LiNbO3) crystals are important dielectric and ferroelectric materials, which are widely used in acoustics, optic, and optoelectrical devices. The physical and chemical properties of LiNbO3 are dependent on microstructures, defects, compositions, and dimensions. In this review, we first discussed the crystal and defect structures of LiNbO3, then the crystallization of LiNbO3 single crystal, and the measuring methods of Li content were introduced to reveal reason of growing congruent LiNbO3 and variable Li/Nb ratios. Afterwards, this review provides a summary about traditional and non-traditional applications of LiNbO3 crystals. The development of rare earth doped LiNbO3 used in illumination, and fluorescence temperature sensing was reviewed. In addition to radio-frequency applications, surface acoustic wave devices applied in high temperature sensor and solid-state physics were discussed. Thanks to its properties of spontaneous ferroelectric polarization, and high chemical stability, LiNbO3 crystals showed enhanced performances in photoelectric detection, electrocatalysis, and battery. Furthermore, domain engineering, memristors, sensors, and harvesters with the use of LiNbO3 crystals were formulated. The review is concluded with an outlook of challenges and potential payoff for finding novel LiNbO3 applications.
Collapse
|
35
|
The EU-SENSE System for Chemical Hazards Detection, Identification, and Monitoring. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112110308] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Chemical reconnaissance, defined as hazards detection, identification, and monitoring, requires tools and solutions which provide reliable and precise data. In this field, the advances of artificial intelligence can be applied. This article aims to propose a novel approach for developing a chemical reconnaissance system that relies on machine learning, modelling algorithms, as well as the contaminant dispersion model to combine signals from different sensors and reduce false alarm rates. A case study of the European Union Horizon 2020 project–EU-SENSE is used and the main features of the system are analysed: heterogeneous sensor nodes components, chemical agents to be detected, and system architecture design. Through the proposed approach, chemical reconnaissance capabilities are improved, resulting in more effective crisis management. The idea for the system design can be used and developed in other areas, namely, in biological or radiological threat reconnaissance.
Collapse
|
36
|
Kingsborough RP, Wrobel AT, Kunz RR. Colourimetry for the sensitive detection of vapour-phase chemicals: State of the art and future trends. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116397] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
37
|
Non-Coding RNA-Based Biosensors for Early Detection of Liver Cancer. Biomedicines 2021; 9:biomedicines9080964. [PMID: 34440168 PMCID: PMC8391662 DOI: 10.3390/biomedicines9080964] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/22/2021] [Accepted: 08/01/2021] [Indexed: 12/27/2022] Open
Abstract
Primary liver cancer is an aggressive, lethal malignancy that ranks as the fourth leading cause of cancer-related death worldwide. Its 5-year mortality rate is estimated to be more than 95%. This significant low survival rate is due to poor diagnosis, which can be referred to as the lack of sufficient and early-stage detection methods. Many liver cancer-associated non-coding RNAs (ncRNAs) have been extensively examined to serve as promising biomarkers for precise diagnostics, prognostics, and the evaluation of the therapeutic progress. For the simple, rapid, and selective ncRNA detection, various nanomaterial-enhanced biosensors have been developed based on electrochemical, optical, and electromechanical detection methods. This review presents ncRNAs as the potential biomarkers for the early-stage diagnosis of liver cancer. Moreover, a comprehensive overview of recent developments in nanobiosensors for liver cancer-related ncRNA detection is provided.
Collapse
|
38
|
Rapid construct superhydrophobic microcracks on the open-surface platform for droplet manipulations. Sci Rep 2021; 11:14915. [PMID: 34290353 PMCID: PMC8295315 DOI: 10.1038/s41598-021-94484-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 07/12/2021] [Indexed: 01/16/2023] Open
Abstract
Droplet-based transport driven by surface tension has been explored as an automated pumping source for several biomedical applications. This paper presented a simple and fast superhydrophobic modify and patterning approach to fabricate various open-surface platforms to manipulate droplets to achieve transport, mixing, concentration, and rebounding control. Several commercial reagents were tested in our approach, and the Glaco reagent was selected to create a superhydrophobic layer; laser cutters are utilized to scan on these superhydrophobic surface to create gradient hydrophilic micro-patterns. Implementing back-and-forth vibrations on the predetermined parallel patterns, droplets can be transported and mixed successfully. Colorimetry of horseradish peroxidase (HRP) mixing with substrates also reduced the reaction time by more than 5-times with the help of superhydrophobic patterned chips. Besides, patterned superhydrophobic chips can significantly improve the sensitivity of colorimetric glucose-sensing by more than 10 times. Moreover, all bioassays were distributed homogeneously within the region of hydrophilic micropatterns without the coffee-ring effect. In addition, to discuss further applications of the surface wettability, the way of controlling the droplet impacting and rebounding phenomenon was also demonstrated. This work reports a rapid approach to modify and patterning superhydrophobic films to perform droplet-based manipulations with a lower technical barrier, higher efficiency, and easier operation. It holds the potential to broaden the applications of open microfluidics in the future.
Collapse
|
39
|
Singh K, Nalabotala R, Koo KM, Bose S, Nayak R, Shiddiky MJA. Separation of distinct exosome subpopulations: isolation and characterization approaches and their associated challenges. Analyst 2021; 146:3731-3749. [PMID: 33988193 DOI: 10.1039/d1an00024a] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Exosomes are nano-sized extracellular vesicles that serve as a communications system between cells and have shown tremendous promise as liquid biopsy biomarkers in diagnostic, prognostic, and even therapeutic use in different human diseases. Due to the natural heterogeneity of exosomes, there is a need to separate exosomes into distinct biophysical and/or biochemical subpopulations to enable full interrogation of exosome biology and function prior to the possibility of clinical translation. Currently, there exists a multitude of different exosome isolation and characterization approaches which can, in limited capacity, separate exosomes based on biophysical and/or biochemical characteristics. While notable reviews in recent years have reviewed these approaches for bulk exosome sorting, we herein present a comprehensive overview of various conventional technologies and modern microfluidic and nanotechnological advancements towards isolation and characterization of exosome subpopulations. The benefits and limitations of these different technologies to improve their use for distinct exosome subpopulations in clinical practices are also discussed. Furthermore, an overview of the most commonly encountered technical and biological challenges for effective separation of exosome subpopulations is presented.
Collapse
Affiliation(s)
- Karishma Singh
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201301, UP, India.
| | - Ruchika Nalabotala
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201301, UP, India.
| | - Kevin M Koo
- The University of Queensland Centre for Clinical Research (UQCCR), Herston, QLD 4029, Australia.
| | - Sudeep Bose
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Noida 201301, UP, India
| | - Ranu Nayak
- Amity Institute of Nanotechnology, Amity University Uttar Pradesh, Noida 201301, UP, India.
| | - Muhammad J A Shiddiky
- School of Environment and Natural Sciences and Queensland Micro- and Nanotechnology Centre, Griffith University, Nathan, QLD 4111, Australia.
| |
Collapse
|
40
|
Xie Z, Pu H, Sun DW. Computer simulation of submicron fluid flows in microfluidic chips and their applications in food analysis. Compr Rev Food Sci Food Saf 2021; 20:3818-3837. [PMID: 34056852 DOI: 10.1111/1541-4337.12766] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Revised: 03/24/2021] [Accepted: 04/15/2021] [Indexed: 01/01/2023]
Abstract
In recent years, countries around the world have maintained a zero-tolerance attitude toward safety problems in the food industry. In order to ensure human health, a fast, sensitive, and high-throughput analysis of food contaminants is necessary to ensure safe food products on the market. Microfluidics, as a high-efficiency and sensitive detection technology, has many advantages in the detection of food contaminants, including foodborne pathogens, pesticides, heavy metal ions, toxic substances, and so forth, especially in conjunction with a variety of submicron fluid driving methods, making food detection and analysis more efficient and accurate. This review introduces the principle of submicron fluid driving modes and discusses the driving simulation of submicron fluid in microfluidic chips. In addition, the latest developments in the application of simulation in food analysis from 2006 to 2020 are discussed, and the computer simulation of submicron fluid flow in microfluidic chips and its application and development trend in food analysis are also highlighted. The review indicates that microfluidic technology, using numerical simulation as an auxiliary tool, combined with traditional methods has greatly improved the detection and analysis of food products. In addition, microfluidics combined with a variety of control methods embodies the ability of specific, multifunctional, and sensitive detection and analysis of food products. The development of high-sensitivity, high-throughput, portable, integrated microfluidic chips will enable the technology to be applied in practice.
Collapse
Affiliation(s)
- Zhaoda Xie
- School of Mechanical and Electrical Engineering, Zhongkai University of Agriculture and Engineering, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China
| | - Hongbin Pu
- School of Food Science and Engineering, South China University of Technology, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China.,Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, China
| | - Da-Wen Sun
- School of Food Science and Engineering, South China University of Technology, Guangzhou, China.,Academy of Contemporary Food Engineering, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, China.,Engineering and Technological Research Centre of Guangdong Province on Intelligent Sensing and Process Control of Cold Chain Foods, & Guangdong Province Engineering Laboratory for Intelligent Cold Chain Logistics Equipment for Agricultural Products, Guangzhou Higher Education Mega Centre, Guangzhou, China.,Food Refrigeration and Computerized Food Technology, School of Agriculture and Food Science Centre, University College Dublin, National University of Ireland, Dublin, Ireland
| |
Collapse
|
41
|
Gouda M, El-Din Bekhit A, Tang Y, Huang Y, Huang L, He Y, Li X. Recent innovations of ultrasound green technology in herbal phytochemistry: A review. ULTRASONICS SONOCHEMISTRY 2021; 73:105538. [PMID: 33819867 PMCID: PMC8048006 DOI: 10.1016/j.ultsonch.2021.105538] [Citation(s) in RCA: 40] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 03/16/2021] [Accepted: 03/20/2021] [Indexed: 05/10/2023]
Abstract
Ultrasound (US) has become one of the most important techniques in green chemistry and emerging technologies. Many research investigations documented the usefulness of US in a wide range of applications in food science, nanotechnology, and complementary medicine, where effective extraction of natural products is important. However, as with all novel technologies, US has advantages and limitations that require clarification for full adaptation at an industrial scale. The present review discusses recent applications of US in herbal phytochemistry with the emphasis on US effects on chemical structures of bioactive compounds extracted from herbs and their bioactivities. The impact of different US processing conditions such as frequency, intensity, duration, temperature, and pressure on the effectiveness of the extraction process and the properties of the extracted materials are also discussed. Different frequencies and intensities of US have demonstrated its potential applications in modifying, determining, and predicting the physicochemical properties of herbs and their extracts. US has important applications in nanotechnology where it supports the fabrication of inexpensive and eco-friendly herbal nanostructures, as well as acoustic-based biosensors for chemical imaging of the herbal tissues. The application of US enhances the rates of chemical processes such as hydrolysis of herbal fibers, which reduces the time and energy consumed without affecting the quality of the final products. Overall, the use of US in herbal science has great potential to create novel chemical constructions and to be used as an innovative diagnostic system in various biomedical, food, and analytical applications.
Collapse
Affiliation(s)
- Mostafa Gouda
- College of Biosystems Engineering and Food Science, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310058, China
- Department of Nutrition & Food Science, National Research Centre, Dokki, Giza, Egypt
| | | | - Yu Tang
- College of Automation, Guangdong Polytechnic Normal University, Guangzhou 510665, China
| | - Yifeng Huang
- College of Civil Engineering and Architecture, East China Jiaotong University, Nanchang 330013, China
| | - Lingxia Huang
- College of Animal Sciences, Zhejiang University, Hangzhou 310058, China
| | - Yong He
- College of Biosystems Engineering and Food Science, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310058, China
| | - Xiaoli Li
- College of Biosystems Engineering and Food Science, Zhejiang University, 866 Yuhangtang Road, Hangzhou 310058, China
| |
Collapse
|
42
|
Li L, Chakik M, Prakash R. A Review of Corrosion in Aircraft Structures and Graphene-Based Sensors for Advanced Corrosion Monitoring. SENSORS 2021; 21:s21092908. [PMID: 33919187 PMCID: PMC8122423 DOI: 10.3390/s21092908] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 04/09/2021] [Accepted: 04/16/2021] [Indexed: 12/16/2022]
Abstract
Corrosion is an ever-present phenomena of material deterioration that affects all metal structures. Timely and accurate detection of corrosion is required for structural maintenance and effective management of structural components during their life cycle. The usage of aircraft materials has been primarily driven by the need for lighter, stronger, and more robust metal alloys, rather than mitigation of corrosion. As such, the overall cost of corrosion management and aircraft downtime remains high. To illustrate, $5.67 billion or 23.6% of total sustainment costs was spent on aircraft corrosion management, as well as 14.1% of total NAD for the US Air Force aviation and missiles in the fiscal year of 2018. The ability to detect and monitor corrosion will allow for a more efficient and cost-effective corrosion management strategy, and will therefore, minimize maintenance costs and downtime, and to avoid unexpected failure associated with corrosion. Conventional and commercial efforts in corrosion detection on aircrafts have focused on visual and other field detection approaches which are time- and usage-based rather than condition-based; they are also less effective in cases where the corroded area is inaccessible (e.g., fuel tank) or hidden (rivets). The ability to target and detect specific corrosion by-products associated with the metals/metal alloys (chloride ions, fluoride ions, iron oxides, aluminum chlorides etc.), corrosion environment (pH, wetness, temperature), along with conventional approaches for physical detection of corrosion can provide early corrosion detection as well as enhanced reliability of corrosion detection. The paper summarizes the state-of-art of corrosion sensing and measurement technologies for schedule-based inspection or continuous monitoring of physical, environmental and chemical presence associated with corrosion. The challenges are reviewed with regards to current gaps of corrosion detection and the complex task of corrosion management of an aircraft, with a focused overview of the corrosion factors and corrosion forms that are pertinent to the aviation industry. A comprehensive overview of thin film sensing techniques for corrosion detection and monitoring on aircrafts are being conducted. Particular attention is paid to innovative new materials, especially graphene-derived thin film sensors which rely on their ability to be configured as a conductor, semiconductor, or a functionally sensitive layer that responds to corrosion factors. Several thin film sensors have been detailed in this review as highly suited candidates for detecting corrosion through direct sensing of corrosion by-products in conjunction with the aforementioned physical and environmental corrosion parameters. The ability to print/pattern these thin film materials directly onto specific aircraft components, or deposit them onto rigid and flexible sensor surfaces and interfaces (fibre optics, microelectrode structures) makes them highly suited for corrosion monitoring applications.
Collapse
Affiliation(s)
- Lucy Li
- Aerospace Research Centre, National Research Council Canada, Ottawa, ON K1A 0R6, Canada
| | - Mounia Chakik
- Department of Electronics Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| | - Ravi Prakash
- Department of Electronics Engineering, Carleton University, Ottawa, ON K1S 5B6, Canada
| |
Collapse
|
43
|
Xia HM, Wu JW, Zheng JJ, Zhang J, Wang ZP. Nonlinear microfluidics: device physics, functions, and applications. LAB ON A CHIP 2021; 21:1241-1268. [PMID: 33877234 DOI: 10.1039/d0lc01120g] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The microfluidic flow is typically laminar due to the dominant viscous effects. At Reynolds numbers far below 1 (Re ≪ 1), the fluid inertia can be neglected. For the steady flow of incompressible Newtonian fluids, it approaches linear Stokes flow. At intermediate Re, there exists a weak-inertia flow regime where secondary flows such as Dean vortices are accessible for microfluidic manipulations. Apart from the fluid inertia, other nonlinear factors such as the non-Newtonian fluid properties, concurrent flow of dissimilar fluids, compliant fluidic structures and stimuli-responsive materials can also cause intriguing flow behaviours. Through proper designs, they can be applied for a variety of microfluidic components including mixers, valves, oscillators, stabilizers and auto-regulators etc., greatly enriching the microfluidic flow control and manipulation strategies. Due to its unique working characteristics and advantages, nonlinear microfluidics has increasingly attracted extensive attention. This review presents a systematic survey on this subject. The designs of typical nonlinear microfluidic devices, their working mechanisms, key applications, and the perspective of their future developments will be discussed. The nonlinear microfluidic techniques are believed to play an essential role in the next generation of highly-integrated, automated, and intelligent microfluidics.
Collapse
Affiliation(s)
- H M Xia
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, P. R. China.
| | | | | | | | | |
Collapse
|
44
|
Guex AG, Di Marzio N, Eglin D, Alini M, Serra T. The waves that make the pattern: a review on acoustic manipulation in biomedical research. Mater Today Bio 2021; 10:100110. [PMID: 33997761 PMCID: PMC8094912 DOI: 10.1016/j.mtbio.2021.100110] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 02/19/2021] [Accepted: 03/13/2021] [Indexed: 02/06/2023] Open
Abstract
Novel approaches, combining technology, biomaterial design, and cutting-edge cell culture, have been increasingly considered to advance the field of tissue engineering and regenerative medicine. Within this context, acoustic manipulation to remotely control spatial cellular organization within a carrier matrix has arisen as a particularly promising method during the last decade. Acoustic or sound-induced manipulation takes advantage of hydrodynamic forces exerted on systems of particles within a liquid medium by standing waves. Inorganic or organic particles, cells, or organoids assemble within the nodes of the standing wave, creating distinct patterns in response to the applied frequency and amplitude. Acoustic manipulation has advanced from micro- or nanoparticle arrangement in 2D to the assembly of multiple cell types or organoids into highly complex in vitro tissues. In this review, we discuss the past research achievements in the field of acoustic manipulation with particular emphasis on biomedical application. We survey microfluidic, open chamber, and high throughput devices for their applicability to arrange non-living and living units in buffer or hydrogels. We also investigate the challenges arising from different methods, and their prospects to gain a deeper understanding of in vitro tissue formation and application in the field of biomedical engineering. Work on sound waves to spatially control particulate systems is reviewed. Classification of surface acoustic waves, bulk acoustic waves, and Faraday waves. Sound can be used to arrange, separate, or filter polymer particles. Sound can pattern cells in 3D to induce morphogenesis. Long-term applied sound induces differentiation and tissue formation.
Collapse
Affiliation(s)
- A G Guex
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - N Di Marzio
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland.,Department of Health Sciences, Università del Piemonte Orientale (UPO), Novara, Italy
| | - D Eglin
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - M Alini
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - T Serra
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| |
Collapse
|
45
|
Ramesan S, Rezk AR, Cevaal PM, Cortez-Jugo C, Symons J, Yeo LY. Acoustofection: High-Frequency Vibrational Membrane Permeabilization for Intracellular siRNA Delivery into Nonadherent Cells. ACS APPLIED BIO MATERIALS 2021; 4:2781-2789. [PMID: 35014317 DOI: 10.1021/acsabm.1c00003] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The internalization of therapeutic molecules into cells-a critical step in enabling a suite of autologous ex vivo gene and cell therapies-is highly regulated by the lipid barrier imposed by the cell membrane. Strategies to increase the efficiency of delivering these exogenous payloads into the cell, while maintaining the integrity of both the therapeutic molecules to be delivered as well as the host cells they are delivered to, are therefore required. This is especially the case for suspension cells that are particularly difficult to transfect. In this work, we show that it is possible to enhance the uptake of short interfering RNA (siRNA) into nonadherent Jurkat and HuT 78 cells with a rapid poration-free method involving high-frequency (MHz order) acoustic excitation. The 2-fold enhancement in gene knockdown is almost comparable with that obtained with conventional nucleofection, which is among the most widely used intracellular delivery methods, but with considerably higher cell viabilities (>91% compared to approximately 76%) owing to the absence of pore formation. The rapid and effective delivery afforded by the platform, together with its low cost and scalability, therefore renders it a potent tool in the cell engineering pipeline.
Collapse
Affiliation(s)
- Shwathy Ramesan
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Amgad R Rezk
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| | - Paula M Cevaal
- The Peter Doherty Institute for Infection and Immunity, University of Melbourne and Royal Melbourne Hospital, Melbourne, VIC 3000, Australia
| | - Christina Cortez-Jugo
- Department of Chemical Engineering, University of Melbourne, Parkville, VIC 3010, Australia
| | - Jori Symons
- The Peter Doherty Institute for Infection and Immunity, University of Melbourne and Royal Melbourne Hospital, Melbourne, VIC 3000, Australia
| | - Leslie Y Yeo
- Micro/Nanophysics Research Laboratory, School of Engineering, RMIT University, Melbourne, VIC 3000, Australia
| |
Collapse
|
46
|
Gao Y, Fajrial AK, Yang T, Ding X. Emerging on-chip surface acoustic wave technology for small biomaterials manipulation and characterization. Biomater Sci 2021; 9:1574-1582. [PMID: 33283794 DOI: 10.1039/d0bm01269f] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A surface acoustic wave (SAW) is a sound wave travelling on the surface of an elastic material. SAW offers a robust control of the acoustic energy leading to an unparalleled versatility. As an actuator, SAW can exert acoustic forces on particles and fluids thus enabling dexterous micro/nanoscale manipulations. As a sensor, SAW has a unique sensing capability upon changes in the environment. On-chip SAW technology, in which SAW is integrated with modern lab-on-a-chip (LOC), has drawn a lot of attention in recent years and found various exciting applications in micro/nanosystems. In particular, its well-known biocompatibility provides on-chip SAW technology as an exceptional platform for biomaterials research at the small-scale. In this minireview, we highlighted recent advances of on-chip SAW technology for biomaterials manipulation and characterization with a focus on cell-based (e.g. single-cell and multicellular) biomaterials. We also discussed and shared our perspective on future directions for this emerging research field.
Collapse
Affiliation(s)
- Yu Gao
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| | - Apresio K Fajrial
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| | - Tao Yang
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA.
| | - Xiaoyun Ding
- Paul M. Rady Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO 80309, USA. and Biomedical Engineering Program, University of Colorado Boulder, Boulder, CO 80309, USA
| |
Collapse
|
47
|
García-Valenzuela A, Fakhfouri A, Oliva-Ramírez M, Rico-Gavira V, Rojas TC, Alvarez R, Menzel SB, Palmero A, Winkler A, González-Elipe AR. Patterning and control of the nanostructure in plasma thin films with acoustic waves: mechanical vs. electrical polarization effects. MATERIALS HORIZONS 2021; 8:515-524. [PMID: 34821267 DOI: 10.1039/d0mh01540g] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Nanostructuration and 2D patterning of thin films are common strategies to fabricate biomimetic surfaces and components for microfluidic, microelectronic or photonic applications. This work presents the fundamentals of a surface nanotechnology procedure for laterally tailoring the nanostructure and crystalline structure of thin films that are plasma deposited onto acoustically excited piezoelectric substrates. Using magnetron sputtering as plasma technique and TiO2 as case example, it is demonstrated that the deposited films depict a sub-millimetre 2D pattern that, characterized by large lateral differences in nanostructure, density (up to 50%), thickness, and physical properties between porous and dense zones, reproduces the wave features distribution of the generated acoustic waves (AW). Simulation modelling of the AW propagation and deposition experiments carried out without plasma and under alternative experimental conditions reveal that patterning is not driven by the collision of ad-species with mechanically excited lattice atoms of the substrate, but emerges from their interaction with plasma sheath ions locally accelerated by the AW-induced electrical polarization field developed at the substrate surface and growing film. The possibilities of the AW activation as a general approach for the tailored control of nanostructure, pattern size, and properties of thin films are demonstrated through the systematic variation of deposition conditions and the adjustment of AW operating parameters.
Collapse
Affiliation(s)
- Aurelio García-Valenzuela
- Nanotechnology on Surfaces and Plasma Laboratory, Instituto de Ciencia de Materiales de Sevilla (CSIC-Univ. Sevilla), Avda. Américo Vespucio 49, 41092 Sevilla, Spain.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Peng D, Tong W, Collins DJ, Ibbotson MR, Prawer S, Stamp M. Mechanisms and Applications of Neuromodulation Using Surface Acoustic Waves-A Mini-Review. Front Neurosci 2021; 15:629056. [PMID: 33584193 PMCID: PMC7873291 DOI: 10.3389/fnins.2021.629056] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 01/07/2021] [Indexed: 12/19/2022] Open
Abstract
The study of neurons is fundamental for basic neuroscience research and treatment of neurological disorders. In recent years ultrasound has been increasingly recognized as a viable method to stimulate neurons. However, traditional ultrasound transducers are limited in the scope of their application by self-heating effects, limited frequency range and cavitation effects during neuromodulation. In contrast, surface acoustic wave (SAW) devices, which are producing wavemodes with increasing application in biomedical devices, generate less self-heating, are smaller and create less cavitation. SAW devices thus have the potential to address some of the drawbacks of traditional ultrasound transducers and could be implemented as miniaturized wearable or implantable devices. In this mini review, we discuss the potential mechanisms of SAW-based neuromodulation, including mechanical displacement, electromagnetic fields, thermal effects, and acoustic streaming. We also review the application of SAW actuation for neuronal stimulation, including growth and neuromodulation. Finally, we propose future directions for SAW-based neuromodulation.
Collapse
Affiliation(s)
- Danli Peng
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Wei Tong
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, VIC, Australia
| | - David J. Collins
- Biomedical Engineering Department, The University of Melbourne, Melbourne, VIC, Australia
| | - Michael R. Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, VIC, Australia
| | - Steven Prawer
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Melanie Stamp
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
49
|
DeCastro J, Littig J, Chou PP, Mack-Onyeike J, Srinivasan A, Conboy MJ, Conboy IM, Aran K. The Microfluidic Toolbox for Analyzing Exosome Biomarkers of Aging. Molecules 2021; 26:535. [PMID: 33498573 PMCID: PMC7864353 DOI: 10.3390/molecules26030535] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/04/2021] [Accepted: 01/14/2021] [Indexed: 12/30/2022] Open
Abstract
As the fields of aging and neurological disease expand to liquid biopsies, there is a need to identify informative biomarkers for the diagnosis of neurodegeneration and other age-related disorders such as cancers. A means of high-throughput screening of biomolecules relevant to aging can facilitate this discovery in complex biofluids, such as blood. Exosomes, the smallest of extracellular vesicles, are found in many biofluids and, in recent years, have been found to be excellent candidates as liquid biopsy biomarkers due to their participation in intercellular communication and various pathologies such as cancer metastasis. Recently, exosomes have emerged as novel biomarkers for age-related diseases. Hence, the study of exosomes, their protein and genetic cargo can serve as early biomarkers for age-associated pathologies, especially neurodegenerative diseases. However, a disadvantage of exosome studies includes a lack in standardization of isolating, detecting, and profiling exosomes for downstream analysis. In this review, we will address current techniques for high-throughput isolation and detection of exosomes through various microfluidic and biosensing strategies and how they may be adapted for the detection of biomarkers of age-associated disorders.
Collapse
Affiliation(s)
- Jonalyn DeCastro
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA 91711, USA; (J.D.); (J.L.); (J.M.-O.)
| | - Joshua Littig
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA 91711, USA; (J.D.); (J.L.); (J.M.-O.)
| | | | - Jada Mack-Onyeike
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA 91711, USA; (J.D.); (J.L.); (J.M.-O.)
| | - Amrita Srinivasan
- Claremont McKenna College, The Claremont Colleges, Claremont, CA 91711, USA;
| | - Michael J. Conboy
- Department of Bioengineering, University of California, Berkeley, CA 94720, USA; (M.J.C.); (I.M.C.)
| | - Irina M. Conboy
- Department of Bioengineering, University of California, Berkeley, CA 94720, USA; (M.J.C.); (I.M.C.)
| | - Kiana Aran
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA 91711, USA; (J.D.); (J.L.); (J.M.-O.)
- Department of Bioengineering, University of California, Berkeley, CA 94720, USA; (M.J.C.); (I.M.C.)
| |
Collapse
|
50
|
Surface Acoustic Wave Sensor for C-Reactive Protein Detection. SENSORS 2020; 20:s20226640. [PMID: 33228249 PMCID: PMC7699588 DOI: 10.3390/s20226640] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/17/2020] [Accepted: 11/18/2020] [Indexed: 12/21/2022]
Abstract
A surface acoustic wave (SAW) sensor was investigated for its application in C-reactive protein (CRP) detection. Piezoelectric lithium niobate (LiNbO3) substrates were used to study their frequency response characteristics in a SAW sensor with a CRP sensing area. After the fabrication of the SAW sensor, the immobilization process was performed for CRP/anti-CRP interaction. The CRP/anti-CRP interaction can be detected as mass variations in the sensing area. These mass variations may produce changes in the amplitude of sensor response. It was clearly observed that a CRP concentration of 0.1 μg/mL can be detected in the proposed SAW sensor. A good fitting linear relationship between the detected insertion loss (amplitude) and the concentrations of CRP from 0.1 μg/mL to 1 mg/mL was obtained. The detected shifts in the amplitude of insertion loss in SAW sensors for different CRP concentrations may be useful in the diagnosis of risk of cardiovascular diseases.
Collapse
|