1
|
Wirojsaengthong S, Chailapakul O, Tangkijvanich P, Henry CS, Puthongkham P. Size-Dependent Electrochemistry of Laser-Induced Graphene Electrodes. Electrochim Acta 2024; 494:144452. [PMID: 38881690 PMCID: PMC11173329 DOI: 10.1016/j.electacta.2024.144452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/18/2024]
Abstract
Laser-induced graphene (LIG) electrodes have become popular for electrochemical sensor fabrication due to their simplicity for batch production without the use of reagents. The high surface area and favorable electrocatalytic properties also enable the design of small electrochemical devices while retaining the desired electrochemical performance. In this work, we systematically investigated the effect of LIG working electrode size, from 0.8 mm to 4.0 mm diameter, on their electrochemical properties, since it has been widely assumed that the electrochemistry of LIG electrodes is independent of size above the microelectrode size regime. The background and faradaic current from cyclic voltammetry (CV) of an outer-sphere redox probe [Ru(NH3)6]3+ showed that smaller LIG electrodes had a higher electrode roughness factor and electroactive surface ratio than those of the larger electrodes. Moreover, CV of the surface-sensitive redox probes [Fe(CN)6]3- and dopamine revealed that smaller electrodes exhibited better electrocatalytic properties, with enhanced electron transfer kinetics. Scanning electron microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy showed that the physical and chemical surface structure were different at the electrode center versus the edges, so the electrochemical properties of the smaller electrodes were improved by having rougher surface and more density of the graphitic edge planes, and more oxide-containing groups, leading to better electrochemistry. The difference could be explained by the different photothermal reaction time from the laser scribing process that causes different stable carbon morphology to form on the polymer surface. Our results give a new insight on relationships between surface structure and electrochemistry of LIG electrodes and are useful for designing miniaturized electrochemical devices.
Collapse
Affiliation(s)
- Supacha Wirojsaengthong
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Orawon Chailapakul
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Pisit Tangkijvanich
- Center of Excellence in Hepatitis and Liver Cancer, Department of Biochemistry, Faculty of Medicine, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand
| | - Charles S. Henry
- Department of Chemistry, Colorado State University, Fort Collins, CO 80523, United States
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, CO 80523, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, United States
| | - Pumidech Puthongkham
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
2
|
Alsoghier HM, Abd-Elsabour M, Alhamzani AG, Abou-Krisha MM, Assaf HF. Real samples sensitive dopamine sensor based on poly 1,3-benzothiazol-2-yl((4-carboxlicphenyl)hydrazono)acetonitrile on a glassy carbon electrode. Sci Rep 2024; 14:16601. [PMID: 39025924 PMCID: PMC11258363 DOI: 10.1038/s41598-024-65192-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 06/18/2024] [Indexed: 07/20/2024] Open
Abstract
Herein, a novel electrochemical sensor that was used for the first time for sensitive and selective detection of dopamine (DA) was fabricated. The new sensor is based on the decoration of the glassy carbon electrode surface (GC) with a polymer film of 1,3-Benzothiazol-2-yl((4-carboxlicphenyl)hydrazono)) acetonitrile (poly(BTCA). The prepared (poly(BTCA) was examined by using different techniques such as 1H NMR, 13C NMR, FTIR, and UV-visible spectroscopy. The electrochemical investigations of DA were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results obtained showed that the modifier increased the electrocatalytic efficiency with a noticeable increase in the oxidation peak current of DA in 0.1 M phosphate buffer solution (PBS) at an optimum pH of 7.0 and scan rate of 200 mV/s when compared to unmodified GC. The new sensor displays a good performance for detecting DA with a limit of detection (LOD 3σ), and limit of quantification (LOQ 10σ) are 0.28 nM and 94 nM respectively. The peak current of DA is linearly proportional to the concentration in the range from 0.1 to 10.0 µM. Additionally, the fabricated electrode showed sufficient reproducibility, stability, and selectivity for DA detection in the presence of different interferents. The proposed poly(BTCA)/GCE sensor was effectively applied to detect DA in the biological samples.
Collapse
Affiliation(s)
- Hesham M Alsoghier
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt.
| | - Mohamed Abd-Elsabour
- Chemistry Department, Faculty of Science, Luxor University, Luxor, 85951, Egypt.
| | - Abdulrahman G Alhamzani
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), 11623, Riyadh, Saudi Arabia
| | - Mortaga M Abou-Krisha
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), 11623, Riyadh, Saudi Arabia
| | - Hytham F Assaf
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt
| |
Collapse
|
3
|
Ostertag BJ, Porshinsky EJ, Nawarathne CP, Ross AE. Surface-Roughened Graphene Oxide Microfibers Enhance Electrochemical Reversibility. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:12124-12136. [PMID: 38815131 PMCID: PMC11209849 DOI: 10.1021/acs.langmuir.4c01004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2024]
Abstract
Here, we provide an optimized method for fabricating surface-roughened graphene oxide disk microelectrodes (GFMEs) with enhanced defect density to generate a more suitable electrode surface for dopamine detection with fast-scan cyclic voltammetry (FSCV). FSCV detection, which is often influenced by adsorption-based surface interactions, is commonly impacted by the chemical and geometric structure of the electrode's surface, and graphene oxide is a tunable carbon-based nanomaterial capable of enhancing these two key characteristics. Synthesized GFMEs possess exquisite electronic and mechanical properties. We have optimized an applied inert argon (Ar) plasma treatment to increase defect density, with minimal changes in chemical functionality, for enhanced surface crevices to momentarily trap dopamine during detection. Optimal Ar plasma treatment (100 sccm, 60 s, 100 W) generates crevice depths of 33.4 ± 2.3 nm with high edge plane character enhancing dopamine interfacial interactions. Increases in GFME surface roughness improve electron transfer rates and limit diffusional rates out of the crevices to create nearly reversible dopamine electrochemical redox interactions. The utility of surface-roughened disk GFMEs provides comparable detection sensitivities to traditional cylindrical carbon fiber microelectrodes while improving temporal resolution ten-fold with amplified oxidation current due to dopamine cyclization. Overall, surface-roughened GFMEs enable improved adsorption interactions, momentary trapping, and current amplification, expanding the utility of GO microelectrodes for FSCV detection.
Collapse
Affiliation(s)
- Blaise J. Ostertag
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower Cincinnati, OH 45221-0172, USA
| | - Evan J. Porshinsky
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower Cincinnati, OH 45221-0172, USA
| | - Chaminda P. Nawarathne
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower Cincinnati, OH 45221-0172, USA
| | - Ashley E. Ross
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower Cincinnati, OH 45221-0172, USA
| |
Collapse
|
4
|
Phamonpon W, Hinestroza JP, Puthongkham P, Rodthongkum N. Surface-engineered natural fibers: Emerging alternative substrates for chemical sensor applications: A review. Int J Biol Macromol 2024; 269:132185. [PMID: 38723830 DOI: 10.1016/j.ijbiomac.2024.132185] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 04/26/2024] [Accepted: 05/06/2024] [Indexed: 05/14/2024]
Abstract
Natural fiber has become one of the most widely used alternative materials for chemical sensor fabrication due to its advantages, such as biocompatibility, flexibility, and self-microfluidic properties. Enhanced natural fiber surface has been used as a substrate in colorimetric and electrochemical sensors. This review focuses on improving the natural fiber properties for preparation as a substrate for chemical sensors. Various methods for natural fiber extraction are discussed and compared. Bleaching and decolorization is important for preparation of colorimetric sensors, while carbonization and nanoparticle doping are favorable for increasing their electrical conductivity for electrochemical sensor fabrication. Also, example fabrications and applications of natural fiber-based chemical sensors for chemical and biomarker detection are discussed. The selectivity of the sensors can be introduced and improved by surface modification of natural fiber, such as enzyme immobilization and biorecognition element functionalization, illustrating the adaptability of natural fiber as a smart sensing device, e.g., wearable and portable sensors. Ultimately, the high performances of natural fiber-based chemical sensors indicate the potential uses of natural fiber as a renewable and eco-friendly substrate material in the field of chemical sensors and biosensors for clinical diagnosis and environmental monitoring.
Collapse
Affiliation(s)
- Wisarttra Phamonpon
- Nanoscience and Technology Program, Graduate School, Chulalongkorn University, Phayathai Road, Pathumwan, Bangkok 10330, Thailand
| | - Juan P Hinestroza
- Department of Fiber Science, College of Human Ecology, Cornell University, Ithaca, NY 14850, United States
| | - Pumidech Puthongkham
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand.
| | - Nadnudda Rodthongkum
- Metallurgy and Materials Science Research Institute, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand; Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Soi Chula 12, Phayathai Road, Pathumwan, Bangkok 10330, Thailand.
| |
Collapse
|
5
|
Plačkić A, Neubert TJ, Patel K, Kuhl M, Watanabe K, Taniguchi T, Zurutuza A, Sordan R, Balasubramanian K. Electrochemistry at the Edge of a van der Waals Heterostructure. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2306361. [PMID: 38109121 DOI: 10.1002/smll.202306361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 10/19/2023] [Indexed: 12/19/2023]
Abstract
Artificial van der Waals heterostructures, obtained by stacking two-dimensional (2D) materials, represent a novel platform for investigating physicochemical phenomena and applications. Here, the electrochemistry at the one-dimensional (1D) edge of a graphene sheet, sandwiched between two hexagonal boron nitride (hBN) flakes, is reported. When such an hBN/graphene/hBN heterostructure is immersed in a solution, the basal plane of graphene is encapsulated by hBN, and the graphene edge is exclusively available in the solution. This forms an electrochemical nanoelectrode, enabling the investigation of electron transfer using several redox probes, e.g., ferrocene(di)methanol, hexaammineruthenium, methylene blue, dopamine and ferrocyanide. The low capacitance of the van der Waals edge electrode facilitates cyclic voltammetry at very high scan rates (up to 1000 V s-1), allowing voltammetric detection of redox species down to micromolar concentrations with sub-second time resolution. The nanoband nature of the edge electrode allows operation in water without added electrolyte. Finally, two adjacent edge electrodes are realized in a redox-cycling format. All the above-mentioned phenomena can be investigated at the edge, demonstrating that nanoscale electrochemistry is a new application avenue for van der Waals heterostructures. Such an edge electrode will be useful for studying electron transfer mechanisms and the detection of analyte species in ultralow sample volumes.
Collapse
Affiliation(s)
- Aleksandra Plačkić
- L-NESS, Department of Physics, Politecnico di Milano, Via Anzani 42, Como, 22100, Italy
- BioSense Institute, University of Novi Sad, Dr Zorana Đinđića 1, Novi Sad, 21000, Serbia
| | - Tilmann J Neubert
- School of Analytical Sciences Adlershof (SALSA), IRIS Adlershof & Department of Chemistry, Humboldt-Universität zu Berlin, Unter den Linden 6, 10099, Berlin, Germany
| | - Kishan Patel
- L-NESS, Department of Physics, Politecnico di Milano, Via Anzani 42, Como, 22100, Italy
| | - Michel Kuhl
- School of Analytical Sciences Adlershof (SALSA), IRIS Adlershof & Department of Chemistry, Humboldt-Universität zu Berlin, Unter den Linden 6, 10099, Berlin, Germany
| | - Kenji Watanabe
- National Institute for Materials Science, 1-1 Namiki, Tsukuba, 305-0044, Japan
| | - Takashi Taniguchi
- National Institute for Materials Science, 1-1 Namiki, Tsukuba, 305-0044, Japan
| | - Amaia Zurutuza
- Graphenea Semiconductor SLU, Mikeletegi Pasealekua 83, San Sebastián, 20009, Spain
| | - Roman Sordan
- L-NESS, Department of Physics, Politecnico di Milano, Via Anzani 42, Como, 22100, Italy
| | - Kannan Balasubramanian
- School of Analytical Sciences Adlershof (SALSA), IRIS Adlershof & Department of Chemistry, Humboldt-Universität zu Berlin, Unter den Linden 6, 10099, Berlin, Germany
| |
Collapse
|
6
|
Alexander E, Leong KW. Nanodiamonds in biomedical research: Therapeutic applications and beyond. PNAS NEXUS 2024; 3:pgae198. [PMID: 38983694 PMCID: PMC11231952 DOI: 10.1093/pnasnexus/pgae198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Accepted: 05/06/2024] [Indexed: 07/11/2024]
Abstract
Nanodiamonds (NDs) comprise a family of carbon-based nanomaterials (i.e. diameter <100 nm) with the same sp3 lattice structure that gives natural diamonds their exceptional hardness and electrical insulating properties. Among all carbon nanomaterials-e.g. carbon nanotubes, nanodots, and fullerenes-NDs are of particular interest for biomedical applications because they offer high biocompatibility, stability in vivo, and a dynamic surface chemistry that can be manipulated to perform a seemingly limitless variety of ultra-specific tasks. NDs are already deepening our understanding of basic biological processes, while numerous laboratories continue studying these nanomaterials with an aim of making seismic improvements in the prevention, diagnosis, and treatment of human diseases. This review surveys approximately 2,000 the most recent articles published in the last 5 years and includes references to more than 150 of the most relevant publications on the biomedical applications of NDs. The findings are categorized by contemporary lines of investigation based on potential applications, namely: genetics and gene editing, drug delivery systems, neural interfacing, biomedical sensors, synthetic biology, and organ and tissue regeneration. This review also includes a brief background of NDs and the methods currently developed for their synthesis and preparation. Finally, recommendations for future investigations are offered.
Collapse
Affiliation(s)
- Elena Alexander
- Department of Biomedical Engineering, Columbia University, New York, NY 10032, USA
| | - Kam W Leong
- Department of Biomedical Engineering, Columbia University, New York, NY 10032, USA
| |
Collapse
|
7
|
Ostertag BJ, Syeed AJ, Brooke AK, Lapsley KD, Porshinsky EJ, Ross AE. Waste Coffee Ground-Derived Porous Carbon for Neurochemical Detection. ACS Sens 2024; 9:1372-1381. [PMID: 38380643 PMCID: PMC11209848 DOI: 10.1021/acssensors.3c02383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2024]
Abstract
We present an optimized synthetic method for repurposing coffee waste to create controllable, uniform porous carbon frameworks for biosensor applications to enhance neurotransmitter detection with fast-scan cyclic voltammetry. Harnessing porous carbon structures from biowastes is a common practice for low-cost energy storage applications; however, repurposing biowastes for biosensing applications has not been explored. Waste coffee ground-derived porous carbon was synthesized by chemical activation to form multivoid, hierarchical porous carbon, and this synthesis was specifically optimized for porous uniformity and electrochemical detection. These materials, when modified on carbon-fiber microelectrodes, exhibited high surface roughness and pore distribution, which contributed to significant improvements in electrochemical reversibility and oxidative current for dopamine (3.5 ± 0.4-fold) and other neurochemicals. Capacitive current increases were small, showing evidence of small increases in electroactive surface area. Local trapping of dopamine within the pores led to improved electrochemical reversibility and frequency-independent behavior. Overall, we demonstrate an optimized biowaste-derived porous carbon synthesis for neurotransmitter detection for the first time and show material utility for viable neurotransmitter detection within a tissue matrix. This work supports the notion that controlled surface nanogeometries play a key role in electrochemical detection.
Collapse
Affiliation(s)
- Blaise J. Ostertag
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Ayah J. Syeed
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Alexandra K. Brooke
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Kamya D. Lapsley
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Evan J. Porshinsky
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Ashley E. Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| |
Collapse
|
8
|
Zhang H, Jiang H, Liu X, Wang X. A review of innovative electrochemical strategies for bioactive molecule detection and cell imaging: Current advances and challenges. Anal Chim Acta 2024; 1285:341920. [PMID: 38057043 DOI: 10.1016/j.aca.2023.341920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/13/2023] [Accepted: 10/14/2023] [Indexed: 12/08/2023]
Abstract
Cellular heterogeneity poses a major challenge for tumor theranostics, requiring high-resolution intercellular bioanalysis strategies. Over the past decades, the advantages of electrochemical analysis, such as high sensitivity, good spatio-temporal resolution, and ease of use, have made it the preferred method to uncover cellular differences. To inspire more creative research, herein, we highlight seminal works in electrochemical techniques for biomolecule analysis and bioimaging. Specifically, micro/nano-electrode-based electrochemical techniques enable real-time quantitative analysis of electroactive substances relevant to life processes in the micro-nanostructure of cells and tissues. Nanopore-based technique plays a vital role in biosensing by utilizing nanoscale pores to achieve high-precision detection and analysis of biomolecules with exceptional sensitivity and single-molecule resolution. Electrochemiluminescence (ECL) technology is utilized for real-time monitoring of the behavior and features of individual cancer cells, enabling observation of their dynamic processes due to its capability of providing high-resolution and highly sensitive bioimaging of cells. Particularly, scanning electrochemical microscopy (SECM) and scanning ion conductance microscopy (SICM) which are widely used in real-time observation of cell surface biological processes and three-dimensional imaging of micro-nano structures, such as metabolic activity, ion channel activity, and cell morphology are introduced in this review. Furthermore, the expansion of the scope of cellular electrochemistry research by innovative functionalized electrodes and electrochemical imaging models and strategies to address future challenges and potential applications is also discussed in this review.
Collapse
Affiliation(s)
- Hao Zhang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China
| | - Hui Jiang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China
| | - Xiaohui Liu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China.
| | - Xuemei Wang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, Jiangsu 210096, China.
| |
Collapse
|
9
|
Ostertag BJ, Ross AE. Editors' Choice-Review-The Future of Carbon-Based Neurochemical Sensing: A Critical Perspective. ECS SENSORS PLUS 2023; 2:043601. [PMID: 38170109 PMCID: PMC10759280 DOI: 10.1149/2754-2726/ad15a2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 12/06/2023] [Indexed: 01/05/2024]
Abstract
Carbon-based sensors have remained critical materials for electrochemical detection of neurochemicals, rooted in their inherent biocompatibility and broad potential window. Real-time monitoring using fast-scan cyclic voltammetry has resulted in the rise of minimally invasive carbon fiber microelectrodes as the material of choice for making measurements in tissue, but challenges with carbon fiber's innate properties have limited its applicability to understudied neurochemicals. Here, we provide a critical review of the state of carbon-based real-time neurochemical detection and offer insight into ways we envision addressing these limitations in the future. This piece focuses on three main hinderances of traditional carbon fiber based materials: diminished temporal resolution due to geometric properties and adsorption/desorption properties of the material, poor selectivity/specificity to most neurochemicals, and the inability to tune amorphous carbon surfaces for specific interfacial interactions. Routes to addressing these challenges could lie in methods like computational modeling of single-molecule interfacial interactions, expansion to tunable carbon-based materials, and novel approaches to synthesizing these materials. We hope this critical piece does justice to describing the novel carbon-based materials that have preceded this work, and we hope this review provides useful solutions to innovate carbon-based material development in the future for individualized neurochemical structures.
Collapse
Affiliation(s)
- Blaise J. Ostertag
- University of Cincinnati, Department of Chemistry, Cincinnati, Ohio 45221-0172, United States of America
| | - Ashley E. Ross
- University of Cincinnati, Department of Chemistry, Cincinnati, Ohio 45221-0172, United States of America
| |
Collapse
|
10
|
Ahmad HMN, Andrade A, Song E. Continuous Real-Time Detection of Serotonin Using an Aptamer-Based Electrochemical Biosensor. BIOSENSORS 2023; 13:983. [PMID: 37998158 PMCID: PMC10669129 DOI: 10.3390/bios13110983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 11/02/2023] [Accepted: 11/09/2023] [Indexed: 11/25/2023]
Abstract
Serotonin (5-HT) is a critical neurotransmitter involved in many neuronal functions, and 5-HT depletion has been linked to several mental diseases. The fast release and clearance of serotonin in the extracellular space, low analyte concentrations, and a multitude of interfering species make the detection of serotonin challenging. This work presents an electrochemical aptamer-based biosensing platform that can monitor 5-HT continuously with high sensitivity and selectivity. Our electrochemical sensor showed a response time of approximately 1 min to a step change in the serotonin concentration in continuous monitoring using a single-frequency EIS (electrochemical impedance spectroscopy) technique. The developed sensing platform was able to detect 5-HT in the range of 25-150 nM in the continuous sample fluid flow with a detection limit (LOD) of 5.6 nM. The electrochemical sensor showed promising selectivity against other species with similar chemical structures and redox potentials, including dopamine (DA), norepinephrine (NE), L-tryptophan (L-TP), 5-hydroxyindoleacetic acid (5-HIAA), and 5-hydroxytryptophan (5-HTP). The proposed sensing platform is able to achieve high selectivity in the nanomolar range continuously in real-time, demonstrating the potential for monitoring serotonin from neurons in organ-on-a-chip or brain-on-a-chip-based platforms.
Collapse
Affiliation(s)
- Habib M. N. Ahmad
- Department of Electrical & Computer Engineering, University of New Hampshire, Durham, NH 03824, USA;
| | - Arturo Andrade
- Robert J. & Nancy D. Carney Institute for Brain Science, Brown University, Providence, RI 02912, USA;
- Department of Neuroscience, Brown University, Providence, RI 02912, USA
| | - Edward Song
- Department of Electrical & Computer Engineering, University of New Hampshire, Durham, NH 03824, USA;
| |
Collapse
|
11
|
Zhao H, Shrestha K, Hensley DK, Venton BJ. Carbon nanospikes have improved sensitivity and antifouling properties for adenosine, hydrogen peroxide, and histamine. Anal Bioanal Chem 2023; 415:6039-6050. [PMID: 37505236 PMCID: PMC10867945 DOI: 10.1007/s00216-023-04875-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/11/2023] [Accepted: 07/18/2023] [Indexed: 07/29/2023]
Abstract
Carbon nanospikes (CNSs) are a new nanomaterial that has enhanced surface roughness and surface oxide concentration, increasing the sensitivity for dopamine detection. However, CNS-modified electrodes (CNSMEs) have not been characterized for other neurochemicals, particularly those with higher oxidation potentials. The purpose of this study was to evaluate CNSMEs for the detection of adenosine, hydrogen peroxide (H2O2), and histamine. The sensitivity increased with CNSs, and signals at CNSMEs were about 3.3 times higher than CFMEs. Normalizing for surface area differences using background currents, CNSMEs show an increased signal of 4.8 times for adenosine, 1.5 times for H2O2, and 2 times for histamine. CNSMEs promoted the formation of secondary products for adenosine and histamine, which enables differentiation from other analytes with similar oxidation potentials. CNSs also selectively enhance the sensitivity for adenosine and histamine compared to H2O2. A scan rate test reveals that adenosine is more adsorption-controlled at CNS electrodes than CFMEs. CNSMEs are antifouling for histamine, with less fouling because the polymers formed after histamine electrooxidation do not adsorb due to an elevated number of edge planes. CNSMEs were useful for detecting each analyte applied in brain slices. Because of the hydrophilic surface compared to CFMEs, CNSMEs also have reduced biofouling when used in tissue. Therefore, CNSMEs are useful for tissue measurements of adenosine, hydrogen peroxide, and histamine with high selectivity and low fouling.
Collapse
Affiliation(s)
- He Zhao
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22901, USA
| | - Kailash Shrestha
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22901, USA
| | - Dale K Hensley
- Center for Nanophase Materials Sciences, Oak Ridge National Lab, Oak Ridge, TN, 37831, USA
| | - B Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, VA, 22901, USA.
| |
Collapse
|
12
|
Ostertag B, Ross AE. Wet-Spun Porous Carbon Microfibers for Enhanced Electrochemical Detection. ACS APPLIED MATERIALS & INTERFACES 2023; 15:17601-17611. [PMID: 36989172 PMCID: PMC10316334 DOI: 10.1021/acsami.3c00423] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We present a novel copolymer-based, uniform porous carbon microfiber (PCMF) formed via wet-spinning for significantly improved electrochemical detection. Carbon fiber (CF), fabricated from a polyacrylonitrile (PAN) precursor, is commonly used in batteries or for electrochemical detection of neurochemicals due to its biplanar geometry and desirable edge plane sites with high surface free energy and defects for enhanced analyte interactions. Recently, the presence of pores within carbon materials has presented interesting electrochemistry leading to detection improvements; however, there is currently no method to uniformly create pores on a carbon microfiber surface impacting a broad range of electrochemical applications. Here, we synthesized controllable porous carbon fibers from a spinning dope of the copolymers PAN and poly(methyl methacrylate) (PMMA) in dimethylformamide via wet spinning for the first time. PMMA serves as a sacrificial block introducing macropores of increased edge-plane character on the fiber. Methods were optimized to produce porous CFs at similar dimensions to traditional CF. We prove that an increase in porosity enhances the degree of disorder on the surface, resulting in significantly improved detection capabilities with fast-scan cyclic voltammetry. Local trapping of analytes at porous geometries enables electrochemical reversibility with improved sensitivity, linear range of detection, and measurement temporal resolution. Overall, we demonstrate the utility of a copolymer synthetic method for PCMF fabrication, providing a stable, controlled macroporous fiber framework with enhanced edge plane character. This work will significantly advance fundamental investigations of how pores and edge plane sites influence electrochemical detection.
Collapse
Affiliation(s)
- Blaise Ostertag
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| | - Ashley E. Ross
- University of Cincinnati Department of Chemistry 312 College Dr. 404 Crosley Tower, Cincinnati, OH 45221-0172, USA
| |
Collapse
|
13
|
Khan SR, Wang X, Jiang T, Ju W, Radacsi N, Kadir MA, Rabbani KSE, Cunningham S, Mitra S. Multi-Modal Portable Respiratory Rate Monitoring Device for Childhood Pneumonia Detection. MICROMACHINES 2023; 14:708. [PMID: 37420941 PMCID: PMC10144858 DOI: 10.3390/mi14040708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/09/2023] [Revised: 02/26/2023] [Accepted: 03/21/2023] [Indexed: 07/09/2023]
Abstract
Accurate assessment of Respiratory Rate (RR) is the most important mechanism in detecting pneumonia in low-resource settings. Pneumonia is a disease with one of the highest mortality rates among young children under five. However, the diagnosis of pneumonia for infants remains challenging, especially in low- and middle-income countries (LMIC). In such situations, RR is most often measured manually with visual inspection. Accurate RR measurement requires the child to remain calm without any stress for a few minutes. The difficulty in achieving this with a sick child in a clinical environment can result in errors and misdiagnosis, even more so when the child is crying and non-cooperating around unfamiliar adults. Therefore, we propose an automated novel RR monitoring device built with textile glove and dry electrodes which can make use of the relaxed posture when the child is resting on the carer's lap. This portable system is non-invasive and made with affordable instrumentation integrated on customized textile glove. The glove has multi-modal automated RR detection mechanism that simultaneously uses bio-impedance and accelerometer data. This novel textile glove with dry electrodes can easily be worn by a parent/carer and is washable. The real-time display on a mobile app shows the raw data and the RR value, allowing a healthcare professional to monitor the results from afar. The prototype device has been tested on 10 volunteers with age variation of 3 years to 33 years, including male and female. The maximum variation of measured RR with the proposed system is ±2 compared to the traditional manual counting method. It does not create any discomfort for either the child or the carer and can be used up to 60 to 70 sessions/day before recharging.
Collapse
Affiliation(s)
- Sadeque Reza Khan
- School of Engineering and Physical Sciences, Institute of Sensors, Signals and Systems, Heriot-Watt University, Edinburgh EH14 4AS, UK
| | - Xiaohan Wang
- School of Engineering, Institute of Integrated Micro and Nano Systems, The University of Edinburgh, Edinburgh EH9 3FF, UK
| | - Tiantao Jiang
- School of Engineering, Institute of Integrated Micro and Nano Systems, The University of Edinburgh, Edinburgh EH9 3FF, UK
| | - Wei Ju
- School of Engineering, Institute of Integrated Micro and Nano Systems, The University of Edinburgh, Edinburgh EH9 3FF, UK
| | - Norbert Radacsi
- School of Engineering, Institute for Materials and Processes, The University of Edinburgh, Robert Stevenson Road, Edinburgh EH9 3FB, UK
| | - Muhammad Abdul Kadir
- Department of Biomedical Physics and Technology, University of Dhaka, Dhaka 1000, Bangladesh
| | | | - Steve Cunningham
- Centre for Inflammation Research, The University of Edinburgh, Edinburgh EH9 3FF, UK
| | - Srinjoy Mitra
- School of Engineering, Institute of Integrated Micro and Nano Systems, The University of Edinburgh, Edinburgh EH9 3FF, UK
| |
Collapse
|
14
|
Wang S, Liu Y, Zhu A, Tian Y. In Vivo Electrochemical Biosensors: Recent Advances in Molecular Design, Electrode Materials, and Electrochemical Devices. Anal Chem 2023; 95:388-406. [PMID: 36625112 DOI: 10.1021/acs.analchem.2c04541] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Electrochemical biosensors provide powerful tools for dissecting the dynamically changing neurochemical signals in the living brain, which contribute to the insight into the physiological and pathological processes of the brain, due to their high spatial and temporal resolutions. Recent advances in the integration of in vivo electrochemical sensors with cross-disciplinary advances have reinvigorated the development of in vivo sensors with even better performance. In this Review, we summarize the recent advances in molecular design, electrode materials, and electrochemical devices for in vivo electrochemical sensors from molecular to macroscopic dimensions, highlighting the methods to obtain high performance for fulfilling the requirements for determination in the complex brain through flexible and smart design of molecules, materials, and devices. Also, we look forward to the development of next-generation in vivo electrochemical biosensors.
Collapse
Affiliation(s)
- Shidi Wang
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| | - Yuandong Liu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| | - Anwei Zhu
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| | - Yang Tian
- Shanghai Key Laboratory of Green Chemistry and Chemical Processes, Department of Chemistry, School of Chemistry and Molecular Engineering, East China Normal University, Dongchuan Road 500, Shanghai 200241, China
| |
Collapse
|
15
|
Dodevska T, Hadzhiev D, Shterev I. A Review on Electrochemical Microsensors for Ascorbic Acid Detection: Clinical, Pharmaceutical, and Food Safety Applications. MICROMACHINES 2022; 14:mi14010041. [PMID: 36677102 PMCID: PMC9864818 DOI: 10.3390/mi14010041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/18/2022] [Accepted: 12/21/2022] [Indexed: 05/11/2023]
Abstract
Nowadays, micro-sized sensors have become a hot topic in electroanalysis. Because of their excellent analytical features, microelectrodes are well-accepted tools for clinical, pharmaceutical, food safety, and environmental applications. In this brief review, we highlight the state-of-art electrochemical non-enzymatic microsensors for quantitative detection of ascorbic acid (also known as vitamin C). Ascorbic acid is a naturally occurring water-soluble organic compound with antioxidant properties and its quantitative determination in biological fluids, foods, cosmetics, etc., using electrochemical microsensors is of wide interest. Various electrochemical techniques have been applied to detect ascorbic acid with extremely high sensitivity, selectivity, reproducibility, and reliability, and apply to in vivo measurements. This review paper aims to give readers a clear view of advances in areas of electrode modification, successful strategies for signal amplification, and miniaturization techniques used in the electroanalytical devices for ascorbic acid. In conclusion, current challenges related to the microelectrodes design, and future perspectives are outlined.
Collapse
|
16
|
Anjum S, Lou B, Tahir A, Aziz‐ur‐Rehman, Rehan H. Shah Gilani M, Xu G. Electrochemical Detection of Dopamine using a Phenyl Carboxylic Acid-Functionalized Electrode Made by Electrochemical Reduction of a Diazonium Salt. ChemistryOpen 2022; 11:e202200233. [PMID: 36478448 PMCID: PMC9728485 DOI: 10.1002/open.202200233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/08/2022] [Indexed: 12/12/2022] Open
Abstract
A glassy carbon electrode (GCE) has been modified by an in situ electrochemical reduction of an aryldiazonium salt generated from the reaction of 4-aminobenzoic acid and sodium nitrite in acidic ethanolic solution. The as-prepared phenyl carboxylic acid-modified glassy carbon electrode has been, for the first time, used for the electrochemical determination of dopamine. Under optimal experimental parameters, outstanding electrocatalytic activity, high sensitivity at a LOD of 5.6×10-9 m, and broad linearity of 0.1 to 1000 μm were obtained. The crafted electrochemical platform demonstrated excellent stability, specificity, and anti-interference capability towards the sensing of dopamine.
Collapse
Affiliation(s)
- Saima Anjum
- State Key Laboratory of Electroanalytical ChemistryChangchun Institute of Applied ChemistryChinese Academy of SciencesChangchunJilin130022P.R. China
- Chinese Academy of SciencesUniversity of Chinese Academy of SciencesNo. 19A YuquanluBeijing100049P.R. China
- Department of ChemistryGovt. Sadiq College Women UniversityBahawalpurPakistan
| | - Baohua Lou
- State Key Laboratory of Electroanalytical ChemistryChangchun Institute of Applied ChemistryChinese Academy of SciencesChangchunJilin130022P.R. China
| | - Amiza Tahir
- Department of ChemistryGovt. Sadiq College Women UniversityBahawalpurPakistan
| | - Aziz‐ur‐Rehman
- State Key Laboratory of Electroanalytical ChemistryChangchun Institute of Applied ChemistryChinese Academy of SciencesChangchunJilin130022P.R. China
- Chinese Academy of SciencesUniversity of Chinese Academy of SciencesNo. 19A YuquanluBeijing100049P.R. China
- Department of ChemistryBaghdad-ul-Jadeed CampusThe Islamia University of BahawalpurBahawalpurPakistan
| | | | - Guobao Xu
- State Key Laboratory of Electroanalytical ChemistryChangchun Institute of Applied ChemistryChinese Academy of SciencesChangchunJilin130022P.R. China
- University of Science and Technology of ChinaAnhui230026P.R. China
| |
Collapse
|
17
|
Rashwan MS, Anwar ZM, Baskaran H, Martin HB. Fluorescence modulation of nanodiamond NV - centers for neurochemical detection. MRS ADVANCES 2022; 7:766-771. [PMID: 38155750 PMCID: PMC10753872 DOI: 10.1557/s43580-022-00322-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Accepted: 07/18/2022] [Indexed: 12/30/2023]
Abstract
Nanodiamond (ND) with nitrogen vacancy (NV-) color centers has emerged as an important material for quantum sensing and imaging. Fluorescent, carboxylated ND (140 nm) is investigated for the detection of dopamine (DA), caffeine (CA), and ascorbic acid (AA). Over a 200 nM range, DA and CA quenched the ND fluorescence by 7.1 and 9.8%, respectively. For AA, fluorescence was quenched (2.9%) at nM concentrations and enhanced at μM concentrations. The quenching fit well to Langmuir adsorption isotherms. For DA-CA mixtures, the CA at nM concentrations did not affect DA quenching but interfered when at μM concentrations. The DA at nM or μM concentrations lessened CA quenching. For DA-AA mixtures with DA at mM concentrations, AA quenched fluorescence throughout the nM and μM range, with increased quenching in the nM range. These studies support ND fluorescence modulation as a possible sensor modality for bioanalyte detection.
Collapse
Affiliation(s)
- Mai S. Rashwan
- Department of Chemical & Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
- Department of Chemistry, Suez Canal University, Ismailia, Egypt
| | - Zeinab M. Anwar
- Department of Chemistry, Suez Canal University, Ismailia, Egypt
| | - Harihara Baskaran
- Department of Chemical & Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
| | - Heidi B. Martin
- Department of Chemical & Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
18
|
Shao Z, Wilson L, Chang Y, Venton BJ. MPCVD-Grown Nanodiamond Microelectrodes with Oxygen Plasma Activation for Neurochemical Applications. ACS Sens 2022; 7:3192-3200. [PMID: 36223478 PMCID: PMC9855027 DOI: 10.1021/acssensors.2c01803] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Nanodiamonds (NDs) are a carbon nanomaterial that has a diamond core with heteroatoms and defects at the surface. The large surface area, defect sites, and functional groups on NDs make them a promising material for electrochemical sensing. Previously, we dip-coated ND onto carbon-fiber microelectrodes (CFMEs) and found increases in sensitivity, but the coating was sparse. Here, we directly grew thin films of ND on niobium wires using microwave plasma chemical vapor deposition (MP-CVD) to provide full surface coverage. ND microelectrodes show a reliable performance in neurotransmitter detection with good antifouling properties. To improve sensitivity, we oxygen plasma etched ND films to activate the surface and intentionally add defects and oxygen surface functional groups. For fast-scan cyclic voltammetry detection of dopamine, oxygen plasma-etching increases the sensitivity from 21 nA/μM to 90 nA/μM after treatment. Fouling was tested by repeated injections of serotonin or tyramine, and both ND and plasma oxidized nanodiamond (NDO) microelectrodes maintain their currents better compared to CFMEs and therefore are more antifouling. A biofouling test in brain slices shows that ND microelectrodes barely have any current drop, while the more hydrophilic NDO microelectrodes decrease more, but still not as much as CFMEs. Overall, grown ND microelectrodes are promising in neurotransmitter detection with excellent fouling resistance, whereas oxygen plasma etching slightly lowers the fouling resistance but dramatically increases sensitivity.
Collapse
Affiliation(s)
- Zijun Shao
- Dept. of Chemistry, University of Virginia, Charlottesville, VA 22904-4319
| | - Leslie Wilson
- Center for Nanophase Material Science, Oak Ridge National Lab, Oak Ridge, TN, 37831, USA
| | - Yuanyu Chang
- Dept. of Chemistry, University of Virginia, Charlottesville, VA 22904-4319
| | - B. Jill Venton
- Dept. of Chemistry, University of Virginia, Charlottesville, VA 22904-4319
| |
Collapse
|
19
|
Shao Z, Chang Y, Venton BJ. Carbon microelectrodes with customized shapes for neurotransmitter detection: A review. Anal Chim Acta 2022; 1223:340165. [PMID: 35998998 PMCID: PMC9867599 DOI: 10.1016/j.aca.2022.340165] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 07/08/2022] [Accepted: 07/09/2022] [Indexed: 01/26/2023]
Abstract
Carbon is a popular electrode material for neurotransmitter detection due to its good electrochemical properties, high biocompatibility, and inert chemistry. Traditional carbon electrodes, such as carbon fibers, have smooth surfaces and fixed shapes. However, newer studies customize the shape and nanostructure the surface to enhance electrochemistry for different applications. In this review, we show how changing the structure of carbon electrodes with methods such as chemical vapor deposition (CVD), wet-etching, direct laser writing (DLW), and 3D printing leads to different electrochemical properties. The customized shapes include nanotips, complex 3D structures, porous structures, arrays, and flexible sensors with patterns. Nanostructuring enhances sensitivity and selectivity, depending on the carbon nanomaterial used. Carbon nanoparticle modifications enhance electron transfer kinetics and prevent fouling for neurochemicals that are easily polymerized. Porous electrodes trap analyte momentarily on the scale of an electrochemistry experiment, leading to thin layer electrochemical behavior that enhances secondary peaks from chemical reactions. Similar thin layer cell behavior is observed at cavity carbon nanopipette electrodes. Nanotip electrodes facilitate implantation closer to the synapse with reduced tissue damage. Carbon electrode arrays are used to measure from multiple neurotransmitter release sites simultaneously. Custom-shaped carbon electrodes are enabling new applications in neuroscience, such as distinguishing different catecholamines by secondary peaks, detection of vesicular release in single cells, and multi-region measurements in vivo.
Collapse
Affiliation(s)
- Zijun Shao
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA
| | - Yuanyu Chang
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA
| | - B Jill Venton
- Dept. of Chemistry, University of Virginia, Charlottesville, VA, 22904-4319, USA.
| |
Collapse
|
20
|
Three-Dimensional Printing and Its Potential to Develop Sensors for Cancer with Improved Performance. BIOSENSORS 2022; 12:bios12090685. [PMID: 36140070 PMCID: PMC9496342 DOI: 10.3390/bios12090685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2022] [Revised: 08/17/2022] [Accepted: 08/21/2022] [Indexed: 12/24/2022]
Abstract
Cancer is the second leading cause of death globally and early diagnosis is the best strategy to reduce mortality risk. Biosensors to detect cancer biomarkers are based on various principles of detection, including electrochemical, optical, electrical, and mechanical measurements. Despite the advances in the identification of biomarkers and the conventional 2D manufacturing processes, detection methods for cancers still require improvements in terms of selectivity and sensitivity, especially for point-of-care diagnosis. Three-dimensional printing may offer the features to produce complex geometries in the design of high-precision, low-cost sensors. Three-dimensional printing, also known as additive manufacturing, allows for the production of sensitive, user-friendly, and semi-automated sensors, whose composition, geometry, and functionality can be controlled. This paper reviews the recent use of 3D printing in biosensors for cancer diagnosis, highlighting the main advantages and advances achieved with this technology. Additionally, the challenges in 3D printing technology for the mass production of high-performance biosensors for cancer diagnosis are addressed.
Collapse
|
21
|
Chen S, Chen W, Wang Y, Wang X, Ding Y, Zhao D, Liu J. Facile one-pot method of AuNPs/PEDOT/CNT composites for simultaneous detection of dopamine with a high concentration of ascorbic acid and uric acid. RSC Adv 2022; 12:15038-15045. [PMID: 35702427 PMCID: PMC9115873 DOI: 10.1039/d2ra01262f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 04/29/2022] [Indexed: 11/21/2022] Open
Abstract
In this research, a facile one-pot method was used to synthesize gold/poly-3,4-ethylene-dioxythiophene/carbon nanotube (AuNPs/PEDOT/CNTs) composite material. The composite material was investigated by Fourier Transform Infrared spectroscopy (FTIR), X-ray diffraction (XRD) and Scanning Electron Microscopy (SEM). Then the synthesized nanocomposite material was dropped on a bare glassy carbon electrode (GCE) to improve the detection performance of dopamine with a high concentration of ascorbic acid and uric acid. The electrochemical behavior of AuNPs/PEDOT/CNTs/GCE was studied by Cyclic Voltammetry (CV), Differential Pulse Voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Under optimum conditions, AuNPs/PEDOT/CNTs/GCE showed a good linear response in the concentration range from 9.14 to 29.704 μM with a detection limit (LOD) and sensitivity of 0.283 μM and 1.557 μA μM-1, respectively. This sensor was applied to detect practical samples with good average recovery. It also exhibited good reproducibility and stability.
Collapse
Affiliation(s)
- Shaohua Chen
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Wenliang Chen
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Yihua Wang
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Xiufang Wang
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Yi Ding
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Donglin Zhao
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| | - Jiyu Liu
- Anhui Key Laboratory of Advanced Building Materials, Anhui Jianzhu University Hefei 230022 Anhui Province P. R. China
| |
Collapse
|
22
|
Cao Q, Shao Z, Hensley D, Venton BJ. Carbon nanospike coated nanoelectrodes for measurements of neurotransmitters. Faraday Discuss 2022; 233:303-314. [PMID: 34889344 PMCID: PMC8983598 DOI: 10.1039/d1fd00053e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Carbon nanoelectrodes enable the detection of neurotransmitters at the level of single cells, vesicles, synapses and small brain structures. Previously, the etching of carbon fibers and 3D printing based on direct laser writing have been used to fabricate carbon nanoelectrodes, but these methods lack the ability of mass manufacturing. In this paper, we mass fabricate carbon nanoelectrodes by growing carbon nanospikes (CNSs) on metal wires. CNSs have a short, dense and defect-rich surface that produces remarkable electrochemical properties, and they can be mass fabricated on almost any substrate without using catalysts. Tungsten wires and niobium wires were electrochemically etched in batch to form sub micrometer sized tips, and a layer of CNSs was grown on the metal wires using plasma-enhanced chemical vapor deposition (PE-CVD). The thickness of the CNS layer was controlled by the deposition time, and a thin layer of CNSs can effectively cover the entire metal surface while maintaining the tip size within the sub micrometer scale. The etched tungsten wires produced tapered conical nanotips, while the etched niobium wires were long and thin. Both showed excellent sensitivity for the detection of outer sphere ruthenium hexamine and the inner sphere test compound ferricyanide. The CNS nanosensors were used for the measurement of dopamine, serotonin, ascorbic acid and DOPAC with fast-scan cyclic voltammetry. The CNS nanoelectrodes had a large surface area and numerous defect sites, which improved the sensitivity, electron transfer kinetics and adsorption. Finally, the CNS nanoelectrodes were compared with other nanoelectrode fabrication methods, including flame etching, 3D printing, and nanopipettes, which are slower to make and more difficult for mass fabrication. Thus, CNS nanoelectrodes are a promising strategy for the mass fabrication of nanoelectrode sensors for neurotransmitters.
Collapse
Affiliation(s)
- Qun Cao
- Department of Chemistry, University of Virginia, Charlottesville, Virginia, 22904, USA.
| | - Zijun Shao
- Department of Chemistry, University of Virginia, Charlottesville, Virginia, 22904, USA.
| | - Dale Hensley
- Center for Nanophase Material Science, Oak Ridge National Lab, Oak Ridge, Tennessee, 37831, USA
| | - B Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, Virginia, 22904, USA.
| |
Collapse
|
23
|
Syeed AJ, Li Y, Ostertag BJ, Brown JW, Ross AE. Nanostructured carbon-fiber surfaces for improved neurochemical detection. Faraday Discuss 2022; 233:336-353. [PMID: 34935021 PMCID: PMC9125946 DOI: 10.1039/d1fd00049g] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Fundamental insight into the extent to which the nanostructured surface and geometry impacts neurochemical interactions at electrode surfaces could provide significant advances in our ability to design and fabricate ultrasensitive neurochemical detection probes. Here, we investigate the extent to which the nanostructure of the carbon-fiber surface impacts detection of catecholamines and purines with fast-scan cyclic voltammetry (FSCV). Carbon-fibers were treated with argon (Ar) plasma to induce variations in the nano- and micro-structure without changing the functionalization of the surface. We tested variations in topology by measuring the extent to which the flow rate, RF power, and treatment time affect the surface roughness. Flow rates from 50-100 sccm, plasma power from 20-100 W, and treatment times from 30 s to 5 min were compared. Two Ar-treatments were chosen from the optimization studies for comparison, and the surface roughness was evaluated using atomic force microscopy (AFM). To ensure no changes in chemical composition, fibers were analyzed with X-ray photoelectron spectroscopy (XPS). On average, at the optimized Ar-plasma treatment procedure, oxidative current for adenosine and ATP increased by 3.5 ± 1.4-fold and 3.2 ± 0.6-fold, and guanosine and GTP by 1.7 ± 0.3-fold and 1.8 ± 0.3-fold, respectively (n = 9). Dopamine increased by 1.7 ± 0.3-fold. The extent to which changes in the electrode structure impact adsorption, sensitivity, and electron transfer rates were measured. A COMSOL Multiphysics simulation was developed to enable the modeling of mass transport of electroactive species at varying electrode geometries. Overall, this study provides critical insight into the extent to which the nanostructure of the surface impacts the electrochemical detection of neurochemicals.
Collapse
Affiliation(s)
- Ayah J Syeed
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Yuxin Li
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Blaise J Ostertag
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Jared W Brown
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- University of Cincinnati, Department of Chemistry, 312 College Dr 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
24
|
Li Y, Jarosova R, Weese-Myers ME, Ross AE. Graphene-Fiber Microelectrodes for Ultrasensitive Neurochemical Detection. Anal Chem 2022; 94:4803-4812. [PMID: 35274933 DOI: 10.1021/acs.analchem.1c05637] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Here, we have synthesized and characterized graphene-fiber microelectrodes (GFME's) for subsecond detection of neurochemicals with fast-scan cyclic voltammetry (FSCV) for the first time. GFME's exhibited extraordinary properties including faster electron transfer kinetics, significantly improved sensitivity, and ease of tunability that we anticipate will have major impacts on neurochemical detection for years to come. GF's have been used in the literature for various applications; however, scaling their size down to microelectrodes and implementing them as neurochemical microsensors is significantly less developed. The GF's developed in this paper were on average 20-30 μm in diameter and both graphene oxide (GO) and reduced graphene oxide (rGO) fibers were characterized with FSCV. Neat GF's were synthesized using a one-step dimension-confined hydrothermal strategy. FSCV detection has traditionally used carbon-fiber microelectrodes (CFME's) and more recently carbon nanotube fiber electrodes; however, uniform functionalization and direct control of the 3D surface structure of these materials remain limited. The expansion to GFME's will certainly open new avenues for fine-tuning the electrode surface for specific electrochemical detection. When comparing to traditional CFME's, our GFME's exhibited significant increases in electron transfer, redox cycling, fouling resistance, higher sensitivity, and frequency independent behavior which demonstrates their incredible utility as biological sensors.
Collapse
Affiliation(s)
- Yuxin Li
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Romana Jarosova
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Moriah E Weese-Myers
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| | - Ashley E Ross
- Department of Chemistry, University of Cincinnati, 312 College Drive 404 Crosley Tower, Cincinnati, Ohio 45221-0172, United States
| |
Collapse
|
25
|
Suriyaprakash J, Bala K, Shan L, Wu L, Gupta N. Molecular Engineered Carbon-Based Sensor for Ultrafast and Specific Detection of Neurotransmitters. ACS APPLIED MATERIALS & INTERFACES 2021; 13:60878-60893. [PMID: 34920668 DOI: 10.1021/acsami.1c18137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In the quest for designing affordable diagnostic devices with high performance, precisely functionalized carbon-based materials with high accuracy and selectivity are required. Every material has its own unique ability to interact with the analyte, and its performance can be enhanced by probing the interaction mechanism. Herein, p-aminophenol (PAP)-functionalized reduced graphene oxide (rGO) nanoscale material is developed by a one-step synthetic route as an all-organic-based sensor. As the PAP molecules are precisely covalently interacted with the rGO at the basal plane and form a wrinkled-paper-like structure, the functionalized material exhibits an outstanding sensing ability (7.5 nM neurotransmitter dopamine (DA) at a wide linear range, 0.01-100 μM) with fast electrical transduction (<3 s) and good recyclability (∼10 cycles) in a real sample. Combining various analytical and density functional theory (DFT) calculation methods, physicochemical properties and the interaction mechanism of analyte-materials transduction are discussed exclusively. Besides, the potential application of the well-dispersed rGO-PAP gravure ink in flexible-printed electronics fields is explored. This study not only provides new insights into the surface/interface chemistry and working principle of this unique anchoring of PAP on rGO but also offers a new pathway for developing other forms of metal-free/organic functionalized biosensors with high efficiency.
Collapse
Affiliation(s)
- Jagadeesh Suriyaprakash
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China
| | - Kanchan Bala
- Department of Chemistry, Sri Guru Granth Sahib World University, Fatehgarh Sahib, Punjab 140407, India
| | - Lianwei Shan
- School of Materials Science and Engineering, Harbin University of Science and Technology, Harbin 150040, China
| | - Lijun Wu
- Guangdong Provincial Key Laboratory of Nanophotonic Functional Materials and Devices, School of Information and Optoelectronic Science and Engineering, South China Normal University, Guangzhou 510006, China
| | - Neeraj Gupta
- Department of Chemistry and Chemical Sciences, Central University of Himachal Pradesh, Dharamshala, Kangra, Himachal Pradesh 176215, India
| |
Collapse
|
26
|
Ali MA, Hu C, Yuan B, Jahan S, Saleh MS, Guo Z, Gellman AJ, Panat R. Breaking the barrier to biomolecule limit-of-detection via 3D printed multi-length-scale graphene-coated electrodes. Nat Commun 2021; 12:7077. [PMID: 34873183 PMCID: PMC8648898 DOI: 10.1038/s41467-021-27361-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 11/09/2021] [Indexed: 11/22/2022] Open
Abstract
Sensing of clinically relevant biomolecules such as neurotransmitters at low concentrations can enable an early detection and treatment of a range of diseases. Several nanostructures are being explored by researchers to detect biomolecules at sensitivities beyond the picomolar range. It is recognized, however, that nanostructuring of surfaces alone is not sufficient to enhance sensor sensitivities down to the femtomolar level. In this paper, we break this barrier/limit by introducing a sensing platform that uses a multi-length-scale electrode architecture consisting of 3D printed silver micropillars decorated with graphene nanoflakes and use it to demonstrate the detection of dopamine at a limit-of-detection of 500 attomoles. The graphene provides a high surface area at nanoscale, while micropillar array accelerates the interaction of diffusing analyte molecules with the electrode at low concentrations. The hierarchical electrode architecture introduced in this work opens the possibility of detecting biomolecules at ultralow concentrations.
Collapse
Affiliation(s)
- Md. Azahar Ali
- grid.147455.60000 0001 2097 0344Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Chunshan Hu
- grid.147455.60000 0001 2097 0344Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Bin Yuan
- grid.147455.60000 0001 2097 0344Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Sanjida Jahan
- grid.147455.60000 0001 2097 0344Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Mohammad S. Saleh
- grid.147455.60000 0001 2097 0344Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Zhitao Guo
- grid.147455.60000 0001 2097 0344Department of Chemical Engineering, and Wilton E. Scott Institute for Energy Innovation, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Andrew J. Gellman
- grid.147455.60000 0001 2097 0344Department of Chemical Engineering, and Wilton E. Scott Institute for Energy Innovation, Carnegie Mellon University, Pittsburgh, PA 15213 USA
| | - Rahul Panat
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, 15213, USA.
| |
Collapse
|
27
|
Fapanni T, Sardini E, Serpelloni M, Tonello S. 3D Electrochemical Sensor and Microstructuration Using Aerosol Jet Printing. SENSORS (BASEL, SWITZERLAND) 2021; 21:7820. [PMID: 34883822 PMCID: PMC8659431 DOI: 10.3390/s21237820] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 11/19/2021] [Accepted: 11/22/2021] [Indexed: 02/07/2023]
Abstract
Electrochemical sensors are attracting great interest for their different applications. To improve their performances, basic research focuses on two main issues: improve their metrological characteristics (e.g., repeatability, reusability and sensitivity) and investigate innovative fabrication processes. In this work, we demonstrate an innovative microstructuration technique aimed at increasing electrochemical sensor sensitivity to improve electrode active area by an innovative fabrication technique. The process is empowered by aerosol jet printing (AJP), an additive-manufacturing and non-contact printing technique that allows depositing functional inks in precise patterns such as parallel lines and grids. The 3D printed microstructures increased the active surface area by up to 130% without changing the substrate occupancy. Further, electrochemical detection of ferro/ferri-cyanide was used to evaluate the sensitivity of the electrodes. This evaluation points out a sensitivity increase of 2.3-fold on average between bare and fully microstructured devices. The increase of surface area and sensitivity are well linearly correlated as expected, verifying the fitness of our production process. The proposed microstructuration is a viable solution for many applications that requires high sensitivity, and the proposed technique, since it does not require masks or complex procedures, turns out to be flexible and applicable to infinite construction geometries.
Collapse
Affiliation(s)
- Tiziano Fapanni
- Department of Information Engineering, University of Brescia, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Emilio Sardini
- Department of Information Engineering, University of Brescia, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Mauro Serpelloni
- Department of Information Engineering, University of Brescia, 25123 Brescia, Italy; (E.S.); (M.S.)
| | - Sarah Tonello
- Department of Information Engineering, University of Padova, 35131 Padova, Italy;
| |
Collapse
|
28
|
Song H, Liu Y, Fang Y, Zhang D. Carbon-Based Electrochemical Sensors for In Vivo and In Vitro Neurotransmitter Detection. Crit Rev Anal Chem 2021; 53:955-974. [PMID: 34752170 DOI: 10.1080/10408347.2021.1997571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
As essential neurological chemical messengers, neurotransmitters play an integral role in the maintenance of normal mammalian physiology. Aberrant neurotransmitter activity is associated with a range of neurological conditions including Parkinson's disease, Alzheimer's disease, and Huntington's disease. Many studies to date have tested different approaches to detecting neurotransmitters, yet the detection of these materials within the brain, due to the complex environment of the brain and the rapid metabolism of neurotransmitters, remains challenging and an area of active research. There is a clear need for the development of novel neurotransmitter sensing technologies capable of rapidly and sensitively monitoring specific analytes within the brain without adversely impacting the local microenvironment in which they are implanted. Owing to their excellent sensitivity, portability, ease-of-use, amenability to microprocessing, and low cost, electrochemical sensors methods have been widely studied in the context of neurotransmitter monitoring. The present review, thus, surveys current progress in this research field, discussing developed electrochemical neurotransmitter sensors capable of detecting dopamine (DA), serotonin (5-HT), acetylcholine (Ach), glutamate (Glu), nitric oxide (NO), adenosine (ADO), and so on. Of these technologies, those based on carbon nanostructures-modified electrodes including carbon nanotubes (CNTs), graphene (GR), gaphdiyne (GDY), carbon nanofibers (CNFs), and derivatives thereof hold particular promise owing to their excellent biocompatibility and electrocatalytic performance. The continued development of these and related technologies is, thus, likely to lead to major advances in the clinical diagnosis of neurological diseases and the detection of novel biomarkers thereof.
Collapse
Affiliation(s)
- Huijun Song
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, PR China
| | - Yangyang Liu
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, PR China
| | - Yuxin Fang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin, PR China
| | - Di Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, PR China
| |
Collapse
|
29
|
Lotfi Marchoubeh M, Cobb SJ, Abrego Tello M, Hu M, Jaquins-Gerstl A, Robbins EM, Macpherson JV, Michael AC, Fritsch I. Miniaturized probe on polymer SU-8 with array of individually addressable microelectrodes for electrochemical analysis in neural and other biological tissues. Anal Bioanal Chem 2021; 413:6777-6791. [PMID: 33961102 DOI: 10.1007/s00216-021-03327-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/15/2021] [Accepted: 04/01/2021] [Indexed: 01/08/2023]
Abstract
An SU-8 probe with an array of nine, individually addressable gold microband electrodes (100 μm long, 4 μm wide, separated by 4-μm gaps) was photolithographically fabricated and characterized for detection of low concentrations of chemicals in confined spaces and in vivo studies of biological tissues. The probe's shank (6 mm long, 100 μm wide, 100 μm thick) is flexible, but exhibits sufficient sharpness and rigidity to be inserted into soft tissue. Laser micromachining was used to define probe geometry by spatially revealing the underlying sacrificial aluminum layer, which was then etched to free the probes from a silicon wafer. Perfusion with fluorescent nanobeads showed that, like a carbon fiber electrode, the probe produced no noticeable damage when inserted into rat brain, in contrast to damage from an inserted microdialysis probe. The individual addressability of the electrodes allows single and multiple electrode activation. Redox cycling is possible, where adjacent electrodes serve as generators (that oxidize or reduce molecules) and collectors (that do the opposite) to amplify signals of small concentrations without background subtraction. Information about electrochemical mechanisms and kinetics may also be obtained. Detection limits for potassium ferricyanide in potassium chloride electrolyte of 2.19, 1.25, and 2.08 μM and for dopamine in artificial cerebral spinal fluid of 1.94, 1.08, and 5.66 μM for generators alone and for generators and collectors during redox cycling, respectively, were obtained.
Collapse
Affiliation(s)
- Mahsa Lotfi Marchoubeh
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA
| | - Samuel J Cobb
- Yusuf Hamied Department of Chemistry, University of Cambridge, Cambridge, CB2 1EW, UK
- Department of Chemistry and Centre for Doctoral Training in Diamond Science and Technology, and Department of Physics, University of Warwick, Coventry, UK
| | - Miguel Abrego Tello
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA
| | - Mengjia Hu
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA
| | | | - Elaine M Robbins
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, 15260, USA
| | - Julie V Macpherson
- Department of Chemistry and Centre for Doctoral Training in Diamond Science and Technology, and Department of Physics, University of Warwick, Coventry, UK
| | - Adrian C Michael
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, 15260, USA
| | - Ingrid Fritsch
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, AR, 72701, USA.
| |
Collapse
|
30
|
Bekhit M, Blazek T, Gorski W. Electroanalysis of Enzyme Activity in Small Biological Samples: Alkaline Phosphatase. Anal Chem 2021; 93:14280-14286. [PMID: 34637277 DOI: 10.1021/acs.analchem.1c03372] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The discovery of sulfite-stabilized anodic current of hydroquinone (HQ) at high pH was used to develop two new methods for measuring the activity of the key biomarker alkaline phosphatase (ALP). Both approaches relied on the monitoring of ALP-triggered release of HQ from a substrate hydroquinone diphosphate (HQDP) into a pH 10.00 solution. One detected the released HQ via the internally calibrated electrochemical continuous enzyme assay (ICECEA) at a glassy carbon (GC) electrode with no sample incubation. The other used sample incubation with HQDP and quantified the released HQ via a coulometric assay at a commercial glucose test strip (GTS). The assay solution was optimized by investigating the ALP/HQDP/HQ system at a GC electrode. The ICECEA revealed high affinity of ALP for HQDP (Kmapp, 87 μM; Vmax, 0.36 μM min-1) and detected ALP down to 0.022 U L-1. At GTS, ALP was detected down to 0.064 U L-1 in a 1 μL sample of human serum after a 20 min incubation at room temperature. The linear range (R2, 0.994) extended at least up to 1.7 U L-1 ALP, which covered more than the clinical range for ALP in serum. The interferences from the sample matrix including those from indigenous glucose were eliminated using a charge difference ΔQ (=Qtotal - Qsample matrix) as a signal for ALP. Both advances proposed here are direct (no auxiliary enzymes or labels required), accurate (98 ± 3% ALP signal recovery), and precise (relative standard deviation (RSD), <7%). The HQDP-GTS-based assay advances the analysis of ALP activity in microsized real-life samples.
Collapse
Affiliation(s)
- Michael Bekhit
- Department of Chemistry, University of Texas at San Antonio, One UTSA Circle, San Antonio, Texas 78249, United States
| | - Teresa Blazek
- Department of Chemistry, University of Texas at San Antonio, One UTSA Circle, San Antonio, Texas 78249, United States
| | - Waldemar Gorski
- Department of Chemistry, University of Texas at San Antonio, One UTSA Circle, San Antonio, Texas 78249, United States
| |
Collapse
|
31
|
Puthongkham P, Wirojsaengthong S, Suea-Ngam A. Machine learning and chemometrics for electrochemical sensors: moving forward to the future of analytical chemistry. Analyst 2021; 146:6351-6364. [PMID: 34585185 DOI: 10.1039/d1an01148k] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Electrochemical sensors and biosensors have been successfully used in a wide range of applications, but systematic optimization and nonlinear relationships have been compromised for electrode fabrication and data analysis. Machine learning and experimental designs are chemometric tools that have been proved to be useful in method development and data analysis. This minireview summarizes recent applications of machine learning and experimental designs in electroanalytical chemistry. First, experimental designs, e.g., full factorial, central composite, and Box-Behnken are discussed as systematic approaches to optimize electrode fabrication to consider the effects from individual variables and their interactions. Then, the principles of machine learning algorithms, including linear and logistic regressions, neural network, and support vector machine, are introduced. These machine learning models have been implemented to extract complex relationships between chemical structures and their electrochemical properties and to analyze complicated electrochemical data to improve calibration and analyte classification, such as in electronic tongues. Lastly, the future of machine learning and experimental designs in electrochemical sensors is outlined. These chemometric strategies will accelerate the development and enhance the performance of electrochemical devices for point-of-care diagnostics and commercialization.
Collapse
Affiliation(s)
- Pumidech Puthongkham
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand. .,Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Chulalongkorn University, Bangkok 10330, Thailand.,Center of Excellence in Responsive Wearable Materials, Chulalongkorn University, Bangkok 10330, Thailand
| | - Supacha Wirojsaengthong
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
| | - Akkapol Suea-Ngam
- Department of Materials, Department of Bioengineering, and Institute of Biomedical Engineering, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
32
|
Kousar A, Peltola E, Laurila T. Nanostructured Geometries Strongly Affect Fouling of Carbon Electrodes. ACS OMEGA 2021; 6:26391-26403. [PMID: 34660997 PMCID: PMC8515610 DOI: 10.1021/acsomega.1c03666] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 09/22/2021] [Indexed: 05/31/2023]
Abstract
Electrode fouling is a major factor that compromises the performance of biosensors in in vivo usage. It can be roughly classified into (i) electrochemical fouling, caused by the analyte and its reaction products, and (ii) biofouling, caused by proteins and other species in the measurement environment. Here, we examined the effect of electrochemical fouling [in phosphate buffer saline (PBS)], biofouling [in cell-culture media (F12-K) with and without proteins], and their combination on the redox reactions occurring on carbon-based electrodes possessing distinct morphologies and surface chemistry. The effect of biofouling on the electrochemistry of an outer sphere redox probe, [Ru(NH3)6]3+, was negligible. On the other hand, fouling had a marked effect on the electrochemistry of an inner sphere redox probe, dopamine (DA). We observed that the surface geometry played a major role in the extent of fouling. The effect of biofouling on DA electrochemistry was the worst on planar pyrolytic carbon, whereas the multiwalled carbon nanotube/tetrahedral amorphous carbon (MWCNT/ta-C), possessing spaghetti-like morphology, and carbon nanofiber (CNF/ta-C) electrodes were much less seriously affected. The blockage of the adsorption sites for DA by proteins and other components of biological media and electrochemical fouling components (byproducts of DA oxidation) caused rapid surface poisoning. PBS washing for 10 consecutive cycles at 50 mV/s did not improve the electrode performance, except for CNF/ta-C, which performed better after PBS washing. Overall, this study emphasizes the combined effect of biological and electrochemical fouling to be critical for the evaluation of the functionality of a sensor. Thus, electrodes possessing composite nanostructures showed less surface fouling in comparison to those possessing planar geometry.
Collapse
Affiliation(s)
- Ayesha Kousar
- Department
of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland
| | - Emilia Peltola
- Department
of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland
| | - Tomi Laurila
- Department
of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 02150 Espoo, Finland
- Department
of Chemistry and Materials Science, School of Chemical Engineering, Aalto University, 02150 Espoo, Finland
| |
Collapse
|
33
|
Jiwanti PK, Sultana S, Wicaksono WP, Einaga Y. Metal modified carbon-based electrode for CO2 electrochemical reduction: A review. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115634] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
34
|
Devi M, Vomero M, Fuhrer E, Castagnola E, Gueli C, Nimbalkar S, Hirabayashi M, Kassegne S, Stieglitz T, Sharma S. Carbon-based neural electrodes: promises and challenges. J Neural Eng 2021; 18. [PMID: 34404037 DOI: 10.1088/1741-2552/ac1e45] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 08/17/2021] [Indexed: 01/01/2023]
Abstract
Neural electrodes are primary functional elements of neuroelectronic devices designed to record neural activity based on electrochemical signals. These electrodes may also be utilized for electrically stimulating the neural cells, such that their response can be simultaneously recorded. In addition to being medically safe, the electrode material should be electrically conductive and electrochemically stable under harsh biological environments. Mechanical flexibility and conformability, resistance to crack formation and compatibility with common microfabrication techniques are equally desirable properties. Traditionally, (noble) metals have been the preferred for neural electrode applications due to their proven biosafety and a relatively high electrical conductivity. Carbon is a recent addition to this list, which is far superior in terms of its electrochemical stability and corrosion resistance. Carbon has also enabled 3D electrode fabrication as opposed to the thin-film based 2D structures. One of carbon's peculiar aspects is its availability in a wide range of allotropes with specialized properties that render it highly versatile. These variations, however, also make it difficult to understand carbon itself as a unique material, and thus, each allotrope is often regarded independently. Some carbon types have already shown promising results in bioelectronic medicine, while many others remain potential candidates. In this topical review, we first provide a broad overview of the neuroelectronic devices and the basic requirements of an electrode material. We subsequently discuss the carbon family of materials and their properties that are useful in neural applications. Examples of devices fabricated using bulk and nano carbon materials are reviewed and critically compared. We then summarize the challenges, future prospects and next-generation carbon technology that can be helpful in the field of neural sciences. The article aims at providing a common platform to neuroscientists, electrochemists, biologists, microsystems engineers and carbon scientists to enable active and comprehensive efforts directed towards carbon-based neuroelectronic device fabrication.
Collapse
Affiliation(s)
- Mamta Devi
- School of Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh 175075, India
| | - Maria Vomero
- Bioelectronic Systems Laboratory, Columbia University, 500 West 120th Street, New York, NY 10027, United States of America
| | - Erwin Fuhrer
- School of Computing and Electrical Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh 175075 India
| | - Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, United States of America
| | - Calogero Gueli
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Koehler-Allee 080, 79110 Freiburg, Germany
| | - Surabhi Nimbalkar
- NanoFAB.SDSU Research Lab, Department of Mechanical Engineering, San Diego State University and NSF-ERC Center for Neurotechnology (CNT), 5500 Campanile Drive, San Diego, CA 92182, United States of America
| | - Mieko Hirabayashi
- NanoFAB.SDSU Research Lab, Department of Mechanical Engineering, San Diego State University and NSF-ERC Center for Neurotechnology (CNT), 5500 Campanile Drive, San Diego, CA 92182, United States of America
| | - Sam Kassegne
- NanoFAB.SDSU Research Lab, Department of Mechanical Engineering, San Diego State University and NSF-ERC Center for Neurotechnology (CNT), 5500 Campanile Drive, San Diego, CA 92182, United States of America
| | - Thomas Stieglitz
- Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Koehler-Allee 080, 79110 Freiburg, Germany.,BrainLinks-BrainTools Center, University of Freiburg, Georges-Koehler-Allee 080, 79110 Freiburg, Germany.,Bernstein Center Freiburg, University of Freiburg, Hansastr. 9a, 79104 Freiburg, Germany
| | - Swati Sharma
- School of Engineering, Indian Institute of Technology Mandi, Kamand, Himachal Pradesh 175075, India
| |
Collapse
|
35
|
Chen B, Perry D, Teahan J, McPherson IJ, Edmondson J, Kang M, Valavanis D, Frenguelli BG, Unwin PR. Artificial Synapse: Spatiotemporal Heterogeneities in Dopamine Electrochemistry at a Carbon Fiber Ultramicroelectrode. ACS MEASUREMENT SCIENCE AU 2021; 1:6-10. [PMID: 36785735 PMCID: PMC9836071 DOI: 10.1021/acsmeasuresciau.1c00006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
An artificial synapse is developed that mimics ultramicroelectrode (UME) amperometric detection of single cell exocytosis. It comprises the nanopipette of a scanning ion conductance microscope (SICM), which delivers rapid pulses of neurotransmitter (dopamine) locally and on demand at >1000 defined locations of a carbon fiber (CF) UME in each experiment. Analysis of the resulting UME current-space-time data reveals spatiotemporal heterogeneous electrode activity on the nanoscale and submillisecond time scale for dopamine electrooxidation at typical UME detection potentials. Through complementary surface charge mapping and finite element method (FEM) simulations, these previously unseen variations in electrochemical activity are related to heterogeneities in the surface chemistry of the CF UME.
Collapse
Affiliation(s)
- Baoping Chen
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - David Perry
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - James Teahan
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - Ian J. McPherson
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - James Edmondson
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - Minkyung Kang
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - Dimitrios Valavanis
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - Bruno G. Frenguelli
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| | - Patrick R. Unwin
- Department of Chemistry, Molecular Analytical
Science Centre for Doctoral
Training, and School of Life Sciences, University of
Warwick, Coventry, CV4 7AL, United Kingdom
| |
Collapse
|
36
|
Electrochemical treatment in KOH renews and activates carbon fiber microelectrode surfaces. Anal Bioanal Chem 2021; 413:6737-6746. [PMID: 34302181 DOI: 10.1007/s00216-021-03539-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2021] [Revised: 07/02/2021] [Accepted: 07/08/2021] [Indexed: 12/30/2022]
Abstract
Carbon fiber microelectrodes (CFMEs) are the standard electrodes for fast-scan cyclic voltammetry (FSCV) detection of neurotransmitters. CFMEs are generally used untreated but the surface can be activated with different treatments to improve electrochemical performance. In this work, we explored electrochemical treatments to clean and activate the CFME surface. We used different solution conditions for electrochemical treatment and found that electrochemical pretreatment in KOH outperforms treatment in KCl, H2O2, or HCl by accelerating the surface renewal process. The etching rate of carbon with electrochemical treatment in KOH is 37 nm/min, which is 10 times faster than that in the other solutions. Electrochemical treatment in KOH for several minutes regenerates a new carbon surface, which introduces more oxygen functional groups beneficial for adsorption and electron transfer. The KOH-treated CFMEs improved the limit of detection (LOD) to 9 ± 2 nM from 14 ± 4 nM for untreated CFMEs, and they successfully detected stimulated dopamine release in rat brain slices, demonstrating that they are stable and sensitive enough to use in biological systems. Electrochemical treatment in KOH completely restores the electrode sensitivity after biofouling. The proposed electrochemical treatment is simple and fast and can be applied prior to using CFMEs or after use to restore the surface. Thus, the method has potential to be a standard step to clean the carbon surface, or restore the sensitivity of electrodes from biofouling.
Collapse
|
37
|
Castagnola E, Garg R, Rastogi SK, Cohen-Karni T, Cui XT. 3D fuzzy graphene microelectrode array for dopamine sensing at sub-cellular spatial resolution. Biosens Bioelectron 2021; 191:113440. [PMID: 34171734 DOI: 10.1016/j.bios.2021.113440] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 05/28/2021] [Accepted: 06/13/2021] [Indexed: 02/07/2023]
Abstract
The development of a high sensitivity real-time sensor for multi-site detection of dopamine (DA) with high spatial and temporal resolution is of fundamental importance to study the complex spatial and temporal pattern of DA dynamics in the brain, thus improving the understanding and treatments of neurological and neuropsychiatric disorders. In response to this need, here we present high surface area out-of-plane grown three-dimensional (3D) fuzzy graphene (3DFG) microelectrode arrays (MEAs) for highly selective, sensitive, and stable DA electrochemical sensing. 3DFG microelectrodes present a remarkable sensitivity to DA (2.12 ± 0.05 nA/nM, with LOD of 364.44 ± 8.65 pM), the highest reported for nanocarbon MEAs using Fast Scan Cyclic Voltammetry (FSCV). The high surface area of 3DFG allows for miniaturization of electrode down to 2 × 2 μm2, without compromising the electrochemical performance. Moreover, 3DFG MEAs are electrochemically stable under 7.2 million scans of continuous FSCV cycling, present exceptional selectivity over the most common interferents in vitro with minimum fouling by electrochemical byproducts and can discriminate DA and serotonin (5-HT) in response to the injection of their 50:50 mixture. These results highlight the potential of 3DFG MEAs as a promising platform for FSCV based multi-site detection of DA with high sensitivity, selectivity, and spatial resolution.
Collapse
Affiliation(s)
- Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260 Pittsburgh, PA, USA
| | - Raghav Garg
- Department of Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | - Sahil K Rastogi
- Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA
| | - Tzahi Cohen-Karni
- Department of Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA; Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive Pittsburgh, PA, 15219-3110, USA.
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, 3501 Fifth Ave. Pittsburgh, PA 15260 Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, 450 Technology Drive Pittsburgh, PA, 15219-3110, USA; Center for Neural Basis of Cognition, University of Pittsburgh, 4400 Fifth Ave, Pittsburgh, PA 15213, Pittsburgh, PA, 15261, USA.
| |
Collapse
|
38
|
Li Y, Weese ME, Cryan MT, Ross AE. Amine-functionalized carbon-fiber microelectrodes for enhanced ATP detection with fast-scan cyclic voltammetry. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:2320-2330. [PMID: 33960336 PMCID: PMC8202729 DOI: 10.1039/d1ay00089f] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Here, we provide evidence that functionalizing the carbon-fiber surface with amines significantly improves direct electrochemical adenosine triphosphate (ATP) detection with fast-scan cyclic voltammetry (FSCV). ATP is an important extracellular signaling molecule throughout the body and can function as a neurotransmitter in the brain. Several methods have been developed over the years to monitor and quantitate ATP signaling in cells and tissues; however, many of them are limited in temporal resolution or are not capable of measuring ATP directly. FSCV at carbon-fiber microelectrodes is a widely used technique to measure neurotransmitters in real-time. Many electrode treatments have been developed to study the interaction of cationic compounds like dopamine at the carbon surface yet studies investigating how to improve anionic compounds, like ATP, at the carbon fiber surface are lacking. In this work, carbon-fibers were treated with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) which reacts with carboxylic acid groups on the carbon surface followed by reaction with ethylenediamine (EDA) to produce NH2-functionalized carbon surfaces. Overall, we a 5.2 ± 2.5-fold increase in ATP current with an approximately 9-fold increase in amine functionality, as analyzed by X-ray Photoelectron Spectroscopy, on the carbon surface was observed after modification with EDC-EDA. This provides evidence that amine-rich surfaces improve interactions with ATP on the surface. This study provides a detailed analysis of ATP interaction at carbon surfaces and ultimately a method to improve direct and rapid neurological ATP detection in the future.
Collapse
Affiliation(s)
- Yuxin Li
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Moriah E Weese
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Michael T Cryan
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | - Ashley E Ross
- Department of Chemistry, University of Cincinnati, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| |
Collapse
|
39
|
Gupta P, Rahm CE, Griesmer B, Alvarez NT. Carbon Nanotube Microelectrode Set: Detection of Biomolecules to Heavy Metals. Anal Chem 2021; 93:7439-7448. [PMID: 33988989 DOI: 10.1021/acs.analchem.1c00360] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
An ultrasensitive electrochemical microelectrode set (μ-ES), where all three electrodes are made of highly densified carbon nanotube fiber (HD-CNTf) cross sections (length ∼40 μm), embedded in an inert polymer matrix, and exposed open-ended CNTs at the interface, is presented here. Bare open ends of HD-CNTf rods were used as the working (∼40 μm diameter) and counter (∼94 μm diameter) electrodes, while the cross section of a ∼94 μm diameter was electroplated with Ag/AgCl and coated with Nafion to employ as a quasi-reference electrode. The Ag/AgCl/Nafion-coated HD-CNTf rod quasi-reference electrode provided a very stable potential comparable to the commercial porous-junction Ag/AgCl reference electrode. The HD-CNTf rod μ-ES has been evaluated by electrochemical determination of biologically important analytes, i.e., dopamine (DA), β-nicotinamide adenine dinucleotide (NADH), a diuretic drug, i.e., furosemide, and a heavy metal, i.e., lead ions (Pb2+). Different voltammetric techniques were employed during the study, i.e., cyclic voltammetry (CV), square wave voltammetry (SWV), amperometry, and square wave anodic stripping voltammetry (SWASV). The direct metallic connection to CNTs gives access to the exceptional properties of highly ordered open-ended CNTs as electrochemical sensors. The distinct structural and electronic properties of aligned HD-CNTf rods in the μ-ES demonstrate fast electron transfer kinetics and offer excellent detection performance during testing for different analytes with wide linear ranges, excellent sensitivity, and very low limits of detection.
Collapse
Affiliation(s)
- Pankaj Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Connor E Rahm
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Benjamin Griesmer
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Noe T Alvarez
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| |
Collapse
|
40
|
Brain neurochemical monitoring. Biosens Bioelectron 2021; 189:113351. [PMID: 34049083 DOI: 10.1016/j.bios.2021.113351] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 05/05/2021] [Accepted: 05/13/2021] [Indexed: 02/08/2023]
Abstract
Brain neurochemical monitoring aims to provide continuous and accurate measurements of brain biomarkers. It has enabled significant advances in neuroscience for application in clinical diagnostics, treatment, and prevention of brain diseases. Microfabricated electrochemical and optical spectroscopy sensing technologies have been developed for precise monitoring of brain neurochemicals. Here, a comprehensive review on the progress of sensing technologies developed for brain neurochemical monitoring is presented. The review provides a summary of the widely measured clinically relevant neurochemicals and commonly adopted recognition technologies. Recent advances in sampling, electrochemistry, and optical spectroscopy for brain neurochemical monitoring are highlighted and their application are discussed. Existing gaps in current technologies and future directions to design industry standard brain neurochemical sensing devices for clinical applications are addressed.
Collapse
|
41
|
Cao Q, Shao Z, Hensley DK, Lavrik NV, Venton BJ. Influence of Geometry on Thin Layer and Diffusion Processes at Carbon Electrodes. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:2667-2676. [PMID: 33591763 PMCID: PMC7937503 DOI: 10.1021/acs.langmuir.0c03315] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
The geometric structure of carbon electrodes affects their electrochemical behavior, and large-scale surface roughness leads to thin layer electrochemistry when analyte is trapped in pores. However, the current response is always a mixture of both thin layer and diffusion processes. Here, we systematically explore the effects of thin layer electrochemistry and diffusion at carbon fiber (CF), carbon nanospike (CNS), and carbon nanotube yarn (CNTY) electrodes. The cyclic voltammetry (CV) response to the surface-insensitive redox couple Ru(NH3)63+/2+ is tested, so the geometric structure is the only factor. At CFs, the reaction is diffusion-controlled because the surface is smooth. CNTY electrodes have gaps between nanotubes that are about 10 μm deep, comparable with the diffusion layer thickness. CNTY electrodes show clear thin layer behavior due to trapping effects, with more symmetrical peaks and ΔEp closer to zero. CNS electrodes have submicrometer scale roughness, so their CV shape is mostly due to diffusion, not thin layer effects. However, even the 10% contribution of thin layer behavior reduces the peak separation by 30 mV, indicating ΔEp is influenced not only by electron transfer kinetics but also by surface geometry. A new simulation model is developed to quantitate the thin layer and diffusion contributions that explains the CV shape and peak separation for CNS and CNTY electrodes, providing insight on the impact of scan rate and surface structure size. Thus, this study provides key understanding of thin layer and diffusion processes at different surface structures and will enable rational design of electrodes with thin layer electrochemistry.
Collapse
Affiliation(s)
- Qun Cao
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Zijun Shao
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Dale K. Hensley
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States
| | - Nickolay V. Lavrik
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, United States
| | - B. Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
- Corresponding Author: B. Jill Venton,
| |
Collapse
|
42
|
Castagnola E, Robbins EM, Woeppel KM, McGuier M, Golabchi A, Taylor IM, Michael AC, Cui XT. Real-Time Fast Scan Cyclic Voltammetry Detection and Quantification of Exogenously Administered Melatonin in Mice Brain. Front Bioeng Biotechnol 2020; 8:602216. [PMID: 33330433 PMCID: PMC7732424 DOI: 10.3389/fbioe.2020.602216] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 10/30/2020] [Indexed: 01/19/2023] Open
Abstract
Melatonin (MT) has been recently considered an excellent candidate for the treatment of sleep disorders, neural injuries, and neurological diseases. To better investigate the actions of MT in various brain functions, real-time detection of MT concentrations in specific brain regions is much desired. Previously, we have demonstrated detection of exogenously administered MT in anesthetized mouse brain using square wave voltammetry (SWV). Here, for the first time, we show successful detection of exogenous MT in the brain using fast scan cyclic voltammetry (FSCV) on electrochemically pre-activated carbon fiber microelectrodes (CFEs). In vitro evaluation showed the highest sensitivity (28.1 nA/μM) and lowest detection limit (20.2 ± 4.8 nM) ever reported for MT detection at carbon surface. Additionally, an extensive CFE stability and fouling assessment demonstrated that a prolonged CFE pre-conditioning stabilizes the background, in vitro and in vivo, and provides consistent CFE sensitivity over time even in the presence of a high MT concentration. Finally, the stable in vivo background, with minimized CFE fouling, allows us to achieve a drift-free FSCV detection of exogenous administered MT in mouse brain over a period of 3 min, which is significantly longer than the duration limit (usually < 90 s) for traditional in vivo FSCV acquisition. The MT concentration and dynamics measured by FSCV are in good agreement with SWV, while microdialysis further validated the concentration range. These results demonstrated reliable MT detection using FSCV that has the potential to monitor MT in the brain over long periods of time.
Collapse
Affiliation(s)
- Elisa Castagnola
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| | - Elaine M. Robbins
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, United States
| | - Kevin M. Woeppel
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
- Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
| | - Moriah McGuier
- Department of Chemistry, Saint Vincent College, Latrobe, PA, United States
| | - Asiyeh Golabchi
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
- Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
| | - I. Mitch Taylor
- Department of Chemistry, Saint Vincent College, Latrobe, PA, United States
| | - Adrian C. Michael
- Department of Chemistry, University of Pittsburgh, Pittsburgh, PA, United States
| | - Xinyan Tracy Cui
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
- Center for Neural Basis of Cognition, University of Pittsburgh, Pittsburgh, PA, United States
- McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
43
|
Shao Z, Puthongkham P, Hu K, Jia R, Mirkin MV, Venton BJ. Thin layer cell behavior of CNT yarn and cavity carbon nanopipette electrodes: Effect on catecholamine detection. Electrochim Acta 2020; 361. [PMID: 32981947 DOI: 10.1016/j.electacta.2020.137032] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Carbon nanotube yarn microelectrodes (CNTYMEs) are an alternative to carbon-fiber microelectrodes (CFMEs) with interesting electrochemical properties because analyte is momentarily trapped in cavities between the CNTs. Here, we compare fast-scan cyclic voltammetry (FSCV) detection of catecholamines, including dopamine, norepinephrine, and epinephrine, at CNTYMEs, CFMEs, as well as cavity carbon nanopipette electrodes (CNPEs). At CFMEs, current decreases dramatically at high FSCV repetition frequencies. At CNTYMEs, current is almost independent of FSCV repetition frequency because the analytes are trapped in the crevices between CNTs, and thus the electrode acts like a thin-layer cell. At CFMEs, small cyclization product peaks are observed due to an intramolecular cyclization reaction to form leucocatecholamine, which is electroactive, and these peaks are largest for the secondary amine epinephrine. At CNTYMEs, more of the leucocatecholamine cyclization product is detected for all catecholamines because of the enhanced trapping effects, particularly at higher repetition rates where the reaction occurs more frequently and more product is accumulated. For epinephrine, the secondary peaks have larger currents than the primary oxidation peaks at 100 Hz, and similar trends are observed with faster scan rates and 500 Hz repetition frequencies. Finally, we examined CNPEs, which also momentarily trap neurotransmitters. Similar to CNTYMEs, at CNPEs, catecholamines have robust cyclization peaks, particularly at high repetition rates. Thus, CNTYMEs and CNPEs have thin layer cell behavior that facilitates high temporal resolution measurements, but catecholamines CVs are complicated by cyclization reactions. However, those additional peaks could be useful in discriminating the analytes, particularly epinephrine and norepinephrine.
Collapse
Affiliation(s)
- Zijun Shao
- Dept. of Chemistry, University of Virginia, Charlottesville, VA 22901
| | | | - KeKe Hu
- Department of Chemistry and Biochemistry, Queens College-CUNY, Flushing, New York 11367 and Graduate Center of CUNY, New York, NY 10016, USA
| | - Rui Jia
- Department of Chemistry and Biochemistry, Queens College-CUNY, Flushing, New York 11367 and Graduate Center of CUNY, New York, NY 10016, USA
| | - Michael V Mirkin
- Department of Chemistry and Biochemistry, Queens College-CUNY, Flushing, New York 11367 and Graduate Center of CUNY, New York, NY 10016, USA
| | - B Jill Venton
- Dept. of Chemistry, University of Virginia, Charlottesville, VA 22901
| |
Collapse
|
44
|
Li Y, Ross AE. Plasma-treated carbon-fiber microelectrodes for improved purine detection with fast-scan cyclic voltammetry. Analyst 2020; 145:805-815. [PMID: 31820742 DOI: 10.1039/c9an01636h] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Here, we developed N2 and O2 plasma-treated carbon-fiber microelectrodes (CFME) for improved purine detection with fast-scan cyclic voltammetry (FSCV). Plasma treatment affects the topology and functionality of carbon which impacts the electrode-analyte interaction. CFME's are less sensitive to purines compared to catecholamines. Knowledge of how the electrode surface drives purine-electrode interaction would provide insight into methods to improve purine detection. Here, plasma-treated CFME's with N2 and O2 plasma was used to investigate the extent to which the surface functionality and topology affects purine detection and to improve purine sensing with FSCV. On average, O2 plasma increased the oxidative current for adenosine and ATP by 6.0 ± 1.2-fold and 6.4 ± 1.6-fold, and guanosine and GTP by 2.8 ± 0.47-fold and 5.8 ± 1.4-fold, respectively (n = 9). The O2 plasma increased the surface roughness and oxygen functionality. N2 plasma increased the oxidative current for adenosine and ATP by 1.5 ± 0.15-fold and 1.9 ± 0.23-fold, and guanosine and GTP by 1.4 ± 0.20-fold and 1.5 ± 0.20-fold, respectively (n = 11). N2 plasma increased the nitrogen functionality with minimal increases in roughness. Both plasma treatments impacted purines more than dopamine. Langmuir isotherms revealed that both plasma gases impact the theoretical surface coverage and adsorption strength of purines at the electrode. Overall, we show that purine detection is improved at surfaces with increased surface roughness, and oxygen and amine functionality. Plasma-treated CFMEs could be used in the future to study the analyte-electrode interaction of other neurochemicals.
Collapse
Affiliation(s)
- Yuxin Li
- University of Cincinnati, Department of Chemistry, 312 College Dr., 404 Crosley Tower, Cincinnati, OH 45221-0172, USA.
| | | |
Collapse
|
45
|
Wang S, Guo P, Ma G, Wei J, Wang Z, Cui L, Sun L, Wang A. Three-dimensional hierarchical mesoporous carbon for regenerative electrochemical dopamine sensor. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.137016] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
46
|
Cao Q, Shin M, Lavrik NV, Venton BJ. 3D-Printed Carbon Nanoelectrodes for In Vivo Neurotransmitter Sensing. NANO LETTERS 2020; 20:6831-6836. [PMID: 32813535 PMCID: PMC7484348 DOI: 10.1021/acs.nanolett.0c02844] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Direct laser writing, a nano 3D-printing approach, has enabled fabrication of customized carbon microelectrode sensors for neurochemical detection. However, to detect neurotransmitters in tiny biological organisms or synapses, submicrometer nanoelectrodes are required. In this work, we used 3D printing to fabricate carbon nanoelectrode sensors. Customized structures were 3D printed and then pyrolyzed, resulting in free-standing carbon electrodes with nanotips. The nanoelectrodes were insulated with atomic layer deposition of Al2O3 and the nanotips were polished by a focused ion beam to form 600 nm disks. Using fast-scan cyclic voltammetry, the electrodes successfully detected stimulated dopamine in the adult fly brain, demonstrating that they are robust and sensitive enough to use in tiny biological systems. This work is the first demonstration of 3D printing to fabricate free-standing carbon nanoelectrode sensors and will enable batch fabrication of customized nanoelectrode sensors with precise control and excellent reproducibility.
Collapse
Affiliation(s)
- Qun Cao
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Mimi Shin
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| | - Nickolay V. Lavrik
- Center for Nanophase Material Science, Oak Ridge National Lab, Oak Ridge, Tennessee 37831, United States
| | - B. Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, Virginia 22904, United States
| |
Collapse
|
47
|
Cheng Z, Xigong L, Weiyi D, Jingen H, Shuo W, Xiangjin L, Junsong W. Potential use of 3D-printed graphene oxide scaffold for construction of the cartilage layer. J Nanobiotechnology 2020; 18:97. [PMID: 32664992 PMCID: PMC7362511 DOI: 10.1186/s12951-020-00655-w] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Accepted: 07/08/2020] [Indexed: 01/08/2023] Open
Abstract
Background Three-dimensional (3D) printing involves the layering of seed cells, biologically compatible scaffolds, and biological activity factors to precisely recapitulate a biological tissue. Graphene oxide (GO), a type of micro material, has been utilized as a small molecule-transport vehicle. With the proliferation of GO, the biocompatibility of chondrocytes in a microenvironment constructed by 3D printed scaffolds and GO is innovative. Accordingly, we speculate that, as a type of micro material, GO can be used with 3D scaffolds for a uniform distribution in the cartilage layer. Results A qualitative analysis of the chondrocyte-proliferation potential revealed that the culture of 3D printing with a 10% GO scaffold was higher than that of the other groups. Meanwhile, the progress of cell apoptosis was activated. Through scanning electron microscopy, immunofluorescence, and in vivo research, we observed that the newborn cartilage matrix extended along the border of the cartilage and scaffold and matured. After an analysis with immunohistochemical staining with aggrecan and collagen I, the cartilage following the 3D-printed scaffold was thinner than that of the 3D-printed GO scaffold. Furthermore, the collagen I of the cartilage expression in treatment with the GO scaffold was significant from week 2 to 6. Conclusions The findings indicate that a 3D-printed GO scaffold can potentially be utilized for the construction of a cartilage matrix. However, the optimum concentration of GO requires further research and discussion.
Collapse
Affiliation(s)
- Zhong Cheng
- Department of Orthopedic, First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China.,The Sport Medicine Center of the First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Li Xigong
- Department of Orthopedic, First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Diao Weiyi
- The Sport Medicine Center of the First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Hu Jingen
- Department of Orthopedic, First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Wang Shuo
- Department of Orthopedic, First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Lin Xiangjin
- The Sport Medicine Center of the First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China
| | - Wu Junsong
- Department of Orthopedic, First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China. .,The Sport Medicine Center of the First Affiliated Hospital, College of Medicine, Zhejiang University, Qingchun Road 79, Hangzhou, 310003, People's Republic of China.
| |
Collapse
|
48
|
Ko M, Mendecki L, Eagleton AM, Durbin CG, Stolz RM, Meng Z, Mirica KA. Employing Conductive Metal-Organic Frameworks for Voltammetric Detection of Neurochemicals. J Am Chem Soc 2020; 142:11717-11733. [PMID: 32155057 DOI: 10.1021/jacs.9b13402] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
This paper describes the first implementation of an array of two-dimensional (2D) layered conductive metal-organic frameworks (MOFs) as drop-casted film electrodes that facilitate voltammetric detection of redox active neurochemicals in a multianalyte solution. The device configuration comprises a glassy carbon electrode modified with a film of conductive MOF (M3HXTP2; M = Ni, Cu; and X = NH, 2,3,6,7,10,11-hexaiminotriphenylene (HITP) or O, 2,3,6,7,10,11-hexahydroxytriphenylene (HHTP)). The utility of 2D MOFs in voltammetric sensing is measured by the detection of ascorbic acid (AA), dopamine (DA), uric acid (UA), and serotonin (5-HT) in 0.1 M PBS (pH = 7.4). In particular, Ni3HHTP2 MOFs demonstrated nanomolar detection limits of 63 ± 11 nM for DA and 40 ± 17 nM for 5-HT through a wide concentration range (40 nM-200 μM). The applicability in biologically relevant detection was further demonstrated in simulated urine using Ni3HHTP2 MOFs for the detection of 5-HT with a nanomolar detection limit of 63 ± 11 nM for 5-HT through a wide concentration range (63 nM-200 μM) in the presence of a constant background of DA. The implementation of conductive MOFs in voltammetric detection holds promise for further development of highly modular, sensitive, selective, and stable electroanalytical devices.
Collapse
Affiliation(s)
- Michael Ko
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Lukasz Mendecki
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Aileen M Eagleton
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Claudia G Durbin
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Robert M Stolz
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Zheng Meng
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| | - Katherine A Mirica
- Department of Chemistry, Burke Laboratory, Dartmouth College, Hanover, New Hampshire 03755, United States
| |
Collapse
|
49
|
Chang Y, Venton BJ. Optimization of graphene oxide-modified carbon-fiber microelectrode for dopamine detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:2893-2902. [PMID: 32617123 PMCID: PMC7331934 DOI: 10.1039/d0ay00310g] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Graphene oxide (GO) is a carbon-based material that is easily obtained from graphite or graphite oxide. GO has been used broadly for electrochemistry applications and our hypothesis is that GO coating a carbon-fiber microelectrode (CFME) will increase the sensitivity for dopamine by providing more adsorption sites due to the enhancement of oxygen functional groups. Here, we compared drop casting, dip coating, and electrodeposition methods to directly coat commercial GO on CFME surfaces. Dip coating did not result in much GO coating and drop casting resulted in large agglomerations that produced noisy signals and slow rise times. Electrodeposition method with cyclic voltammetry increase the current for dopamine and this method was the most reproducible and had the least noise compared to the other two coating methods. The optimized method used a triangular waveform scanned from -1.2 V to 1.5 V at 100 mV/s for 5 cycles in 0.2 mg/mL GO in water. With fast-scan cyclic voltammetry (FSCV), the optimized GO/CFME enhanced the dopamine oxidation peak two-fold. The sensitivity of the modified electrode is 41±2 nA/μM with a linear range from 25 nM to 1 μM, and a limit of detection of 11 nM. The optimized electrodes were used to detect electrically-stimulated dopamine in brain slices to demonstrate their performance in tissue. Thus, GO can be used to enhance the sensitivity of electrodes for dopamine and improve biological measurements.
Collapse
Affiliation(s)
- Yuanyu Chang
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, United States
| | - B Jill Venton
- Department of Chemistry, University of Virginia, Charlottesville, VA 22904, United States
| |
Collapse
|
50
|
Gupta P, Tsai K, Ruhunage CK, Gupta VK, Rahm CE, Jiang D, Alvarez NT. True Picomolar Neurotransmitter Sensor Based on Open-Ended Carbon Nanotubes. Anal Chem 2020; 92:8536-8545. [PMID: 32406234 DOI: 10.1021/acs.analchem.0c01363] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Neurotransmitters are important chemicals in human physiological systems for initiating neuronal signaling pathways and in various critical health illnesses. However, concentration of neurotransmitters in the human body is very low (nM or pM level) and it is extremely difficult to detect the fluctuation of their concentrations in patients using existing electrochemical biosensors. In this work, we report the performance of highly densified carbon nanotubes fiber (HD-CNTf) cross-sections called rods (diameter ∼ 69 μm, and length ∼ 40 μm) as an ultrasensitive platform for detection of common neurotransmitters. HD-CNTf rods microelectrodes have open-ended CNTs exposed at the interface with electrolytes and cells and display a low impedance value, i.e., 1050 Ω. Their fabrication starts with dry spun CNT fibers that are encapsulated in an insulating polymer to preserve their structure and alignment. Arrays of HD-CNTf rods microelectrodes were applied to detect neurotransmitters, i.e., dopamine (DA), serotonin (5-HT), epinephrine (Epn), and norepinephrine (Norepn), using square wave voltammetry (SWV) and cyclic voltammetry (CV). They demonstrate good linearity in a broad linear range (1 nM to 100 μM) with an excellent limit of detection, i.e., 32 pM, 31 pM, 64 pM, and 9 pM for DA, 5-HT, Epn, and Norepn, respectively. To demonstrate practical application of HD-CNTf rod arrays, detection of DA in human biological fluids and real time monitoring of DA release from living pheochromocytoma (PC12) cells were performed.
Collapse
Affiliation(s)
- Pankaj Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Kyrus Tsai
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Chethani K Ruhunage
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Vandna K Gupta
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Connor E Rahm
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Dehua Jiang
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| | - Noe T Alvarez
- Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States
| |
Collapse
|