1
|
Naghdi T, Ardalan S, Asghari Adib Z, Sharifi AR, Golmohammadi H. Moving toward smart biomedical sensing. Biosens Bioelectron 2023; 223:115009. [PMID: 36565545 DOI: 10.1016/j.bios.2022.115009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Revised: 11/01/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022]
Abstract
The development of novel biomedical sensors as highly promising devices/tools in early diagnosis and therapy monitoring of many diseases and disorders has recently witnessed unprecedented growth; more and faster than ever. Nonetheless, on the eve of Industry 5.0 and by learning from defects of current sensors in smart diagnostics of pandemics, there is still a long way to go to achieve the ideal biomedical sensors capable of meeting the growing needs and expectations for smart biomedical/diagnostic sensing through eHealth systems. Herein, an overview is provided to highlight the importance and necessity of an inevitable transition in the era of digital health/Healthcare 4.0 towards smart biomedical/diagnostic sensing and how to approach it via new digital technologies including Internet of Things (IoT), artificial intelligence, IoT gateways (smartphones, readers), etc. This review will bring together the different types of smartphone/reader-based biomedical sensors, which have been employing for a wide variety of optical/electrical/electrochemical biosensing applications and paving the way for future eHealth diagnostic devices by moving towards smart biomedical sensing. Here, alongside highlighting the characteristics/criteria that should be met by the developed sensors towards smart biomedical sensing, the challenging issues ahead are delineated along with a comprehensive outlook on this extremely necessary field.
Collapse
Affiliation(s)
- Tina Naghdi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Sina Ardalan
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Zeinab Asghari Adib
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Amir Reza Sharifi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran
| | - Hamed Golmohammadi
- Nanosensors Bioplatforms Laboratory, Chemistry and Chemical Engineering Research Center of Iran, 14335-186, Tehran, Iran.
| |
Collapse
|
2
|
Nimbkar S, Leena MM, Moses JA, Anandharamakrishnan C. Microfluidic assessment of nutritional biomarkers: Concepts, approaches and advances. Crit Rev Food Sci Nutr 2022; 64:5113-5127. [PMID: 36503314 DOI: 10.1080/10408398.2022.2150597] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Among various approaches to understand the health status of an individual, nutritional biomarkers can provide valuable information, particularly in terms of deficiencies, if any, and their severity. Commonly, the approach revolves around molecular sciences, and the information gained can support prognosis, diagnosis, remediation, and impact assessment of therapies. Microfluidic platforms can offer benefits of low sample and reagent requirements, low cost, high precision, and lower detection limits, with simplicity in handling and the provision for complete automation and integration with information and communication technologies (ICTs). While several advances are being made, this work details the underlying concepts, with emphasis on different point-of-care devices for the analysis of macro and micronutrient biomarkers. In addition, the scope of using different wearable microfluidic sensors for real-time and noninvasive determination of biomarkers is detailed. While several challenges remain, a strong focus is given on recent advances, presenting the state-of-the-art of this field. With more such biomarkers being discovered and commercialization-driven research, trends indicate the wide prospects of this advancing field in supporting clinicians, food technologists, nutritionists, and others.
Collapse
Affiliation(s)
- Shubham Nimbkar
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - M Maria Leena
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - Jeyan Arthur Moses
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| | - Chinnaswamy Anandharamakrishnan
- Computational Modeling and Nanoscale Processing Unit, National Institute of Food Technology, Entrepreneurship and Management, Ministry of Food Processing Industries, Thanjavur, Tamil Nadu, India
| |
Collapse
|
3
|
CFD Analysis and Life Cycle Assessment of Continuous Synthesis of Magnetite Nanoparticles Using 2D and 3D Micromixers. MICROMACHINES 2022; 13:mi13060970. [PMID: 35744584 PMCID: PMC9230433 DOI: 10.3390/mi13060970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/26/2022] [Accepted: 05/28/2022] [Indexed: 02/04/2023]
Abstract
Magnetite nanoparticles (MNPs) have attracted basic and applied research due to their immense potential to enable applications in fields as varied as drug delivery and bioremediation. Conventional synthesis schemes led to wide particle size distributions and inhomogeneous morphologies and crystalline structures. This has been attributed to the inability to control nucleation and growth processes under the conventional conditions of bulk batch processes. Here, we attempted to address these issues by scaling down the synthesis process aided by microfluidic devices, as they provide highly controlled and stable mixing patterns. Accordingly, we proposed three micromixers with different channel configurations, namely, serpentine, triangular, and a 3D arrangement with abrupt changes in fluid direction. The micromixers were first studied in silico, aided by Comsol Multiphysics® to investigate the obtained mixing patterns, and consequently, their potential for controlled growth and the nucleation processes required to form MNPs of uniform size and crystalline structure. The devices were then manufactured using a low-cost approach based on polymethyl methacrylate (PMMA) and laser cutting. Testing the micromixers in the synthesis of MNPs revealed homogeneous morphologies and particle size distributions, and the typical crystalline structure reported previously. A life cycle assessment (LCA) analysis for the devices was conducted in comparison with conventional batch co-precipitation synthesis to investigate the potential impacts on water and energy consumption. The obtained results revealed that such consumptions are higher than those of the conventional process. However, they can be reduced by conducting the synthesis with reused micromixers, as new PMMA is not needed for their assembly prior to operation. We are certain that the proposed approach represents an advantageous alternative to co-precipitation synthesis schemes, in terms of continuous production and more homogeneous physicochemical parameters of interest such as size, morphologies, and crystalline structure. Future work should be directed towards improving the sustainability indicators of the micromixers’ manufacturing process.
Collapse
|
4
|
Quantitative study for control of air–liquid segmented flow in a 3D-printed chip using a vacuum-driven system. Sci Rep 2022; 12:8986. [PMID: 35643726 PMCID: PMC9148305 DOI: 10.1038/s41598-022-13165-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 03/28/2022] [Indexed: 12/02/2022] Open
Abstract
The formation of droplets or bubbles in a microfluidic system is a significant topic requiring device miniaturization and a small volume of samples. Especially, a two-phase segmented flow can be applied to micro-mixing for chemical reactions and the treatment of heat and mass transfer. In this study, a flow of liquid slugs and bubbles was generated in a 3D-printed chip and controlled by a single pump creating a vacuum at the outlet. The pump and chip device were integrated to form a simple and portable system. The size and flow rate of liquid slugs, obtained through image processing techniques, were analyzed considering several parameters related to hydraulic resistance and pressure drop. In addition, the effect of segmentation on mixing was observed by measuring the intensity change using two different colored inks. The hydraulic resistance of air and liquid flows can be controlled by changing the tube length of air flow and the viscosity of liquid flow. Because the total pressure drop along the channel was produced using a single pump at the outlet of the channel, the size and flow rate of the liquid slugs showed a near linear relation depending on the hydraulic resistances. In contrast, as the total pressure varied with the flow rate of the pump, the size of the liquid slugs showed a nonlinear trend. This indicates that the frequency of the liquid slug formation induced by the squeezed bubble may be affected by several forces during the development of the liquid slugs and bubbles. In addition, each volume of liquid slug segmented by the air is within the range of 10–1 to 2 µL for this microfluidic system. The segmentation contributes to mixing efficiency based on the increased homogeneity factor of liquid. This study provides a new insight to better understand the liquid slug or droplet formation and predict the segmented flow based on the relationship between the resistance, flow rate, and pressure drop.
Collapse
|
5
|
Zhao K, Li C, Wan L, Luo F, Cheng Z, Duan J, Wang N. Optofluidic Platform for Rapid On-Chip Analysis of Total Phosphorus in Surface Water Using Absorption Spectrometry. APPLIED SPECTROSCOPY 2022; 76:599-608. [PMID: 35081753 DOI: 10.1177/00037028211069148] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Optofluidic devices are of high interest for online monitoring and analyzing biochemical targets in water by integrating the complex on-chip pretreatment of target analytes and spectral analysis. Compared with the traditional bulk equipment, versatile optical detection and biochemical analysis are more easily integrated on an optofluidic chip, which promotes the development of on-chip real-time rapid detection and monitoring. Here, we report an optofluidic platform for online monitoring total phosphorous in water by absorption spectrometry, which naturally combines the merits of both the photo-Fenton effect and microfluidics to realize the rapid on-chip digestion of phosphate at room temperature and normal pressure. The functional cells for chromogenic reaction and optical absorption detection are, respectively, fabricated on the platform to analyze the content of total phosphorus in surface water. In the experiment, the on-chip digestion time of phosphate is dramatically declined to 8.6 sec, and thus, the detection time is greatly shortened to a few minutes. The detection range of total phosphorus is demonstrated as 0.005-1.00 mg L-1, which satisfies the detection requirements of most environmental water samples. Its availability for measuring the total phosphorous in real water samples is also verified. Predictably, this platform is adapted to on-chip analysis of many other biochemical targets in water.
Collapse
Affiliation(s)
- Kun Zhao
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Chang Li
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Liang Wan
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Fangzhou Luo
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Zhiliang Cheng
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Jinge Duan
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| | - Ning Wang
- National Engineering Research Center of Fiber Optic Sensing Technology and Networks, 12565Wuhan University of Technology, Wuhan, China
| |
Collapse
|
6
|
Material Design for Enhancing Properties of 3D Printed Polymer Composites for Target Applications. TECHNOLOGIES 2022. [DOI: 10.3390/technologies10020045] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Polymer composites are becoming an important class of materials for a diversified range of industrial applications due to their unique characteristics and natural and synthetic reinforcements. Traditional methods of polymer composite fabrication require machining, manual labor, and increased costs. Therefore, 3D printing technologies have come to the forefront of scientific, industrial, and public attention for customized manufacturing of composite parts having a high degree of control over design, processing parameters, and time. However, poor interfacial adhesion between 3D printed layers can lead to material failure, and therefore, researchers are trying to improve material functionality and extend material lifetime with the addition of reinforcements and self-healing capability. This review provides insights on different materials used for 3D printing of polymer composites to enhance mechanical properties and improve service life of polymer materials. Moreover, 3D printing of flexible energy-storage devices (FESD), including batteries, supercapacitors, and soft robotics using soft materials (polymers), is discussed as well as the application of 3D printing as a platform for bioengineering and earth science applications by using a variety of polymer materials, all of which have great potential for improving future conditions for humanity and planet Earth.
Collapse
|
7
|
Yang SM, Lv S, Zhang W, Cui Y. Microfluidic Point-of-Care (POC) Devices in Early Diagnosis: A Review of Opportunities and Challenges. SENSORS 2022; 22:s22041620. [PMID: 35214519 PMCID: PMC8875995 DOI: 10.3390/s22041620] [Citation(s) in RCA: 49] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 02/07/2022] [Accepted: 02/11/2022] [Indexed: 12/12/2022]
Abstract
The early diagnosis of infectious diseases is critical because it can greatly increase recovery rates and prevent the spread of diseases such as COVID-19; however, in many areas with insufficient medical facilities, the timely detection of diseases is challenging. Conventional medical testing methods require specialized laboratory equipment and well-trained operators, limiting the applicability of these tests. Microfluidic point-of-care (POC) equipment can rapidly detect diseases at low cost. This technology could be used to detect diseases in underdeveloped areas to reduce the effects of disease and improve quality of life in these areas. This review details microfluidic POC equipment and its applications. First, the concept of microfluidic POC devices is discussed. We then describe applications of microfluidic POC devices for infectious diseases, cardiovascular diseases, tumors (cancer), and chronic diseases, and discuss the future incorporation of microfluidic POC devices into applications such as wearable devices and telemedicine. Finally, the review concludes by analyzing the present state of the microfluidic field, and suggestions are made. This review is intended to call attention to the status of disease treatment in underdeveloped areas and to encourage the researchers of microfluidics to develop standards for these devices.
Collapse
Affiliation(s)
- Shih-Mo Yang
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China; (S.-M.Y.); (S.L.)
| | - Shuangsong Lv
- School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China; (S.-M.Y.); (S.L.)
| | - Wenjun Zhang
- Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada;
| | - Yubao Cui
- Clinical Research Center, The Affiliated Wuxi People’s Hospital, Nanjing Medical University, 299 Qingyang Road, Wuxi 214023, China
- Correspondence: ; Tel.: +86-510-853-50368
| |
Collapse
|
8
|
Fu E, Wentland L. A survey of 3D printing technology applied to paper microfluidics. LAB ON A CHIP 2021; 22:9-25. [PMID: 34897346 DOI: 10.1039/d1lc00768h] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Paper microfluidics is a rapidly growing subfield of microfluidics in which paper-like porous materials are used to create analytical devices that are well-suited for use in field applications. 3D printing technology has the potential to positively affect paper microfluidic device development by enabling tools and methods for the creation of devices with well-defined and tunable fluidic networks of porous matrices for high performance signal generation. This critical review focuses on the progress that has been made in using 3D printing technologies to advance the development of paper microfluidic devices. We describe printing work in three general categories: (i) solid support structures for paper microfluidic device components; (ii) channel barrier definition in existing porous materials; and (iii) porous channels for capillary flow, and discuss their value in advancing paper microfluidic device development. Finally, we discuss major areas of focus for highest impact on the next generation of paper microfluidics devices.
Collapse
Affiliation(s)
- Elain Fu
- School of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA.
| | - Lael Wentland
- School of Chemical, Biological, and Environmental Engineering, Oregon State University, Corvallis, OR 97331, USA.
| |
Collapse
|
9
|
Vázquez M, Anfossi L, Ben-Yoav H, Diéguez L, Karopka T, Della Ventura B, Abalde-Cela S, Minopoli A, Di Nardo F, Shukla VK, Teixeira A, Tvarijonaviciute A, Franco-Martínez L. Use of some cost-effective technologies for a routine clinical pathology laboratory. LAB ON A CHIP 2021; 21:4330-4351. [PMID: 34664599 DOI: 10.1039/d1lc00658d] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Classically, the need for highly sophisticated instruments with important economic costs has been a major limiting factor for clinical pathology laboratories, especially in developing countries. With the aim of making clinical pathology more accessible, a wide variety of free or economical technologies have been developed worldwide in the last few years. 3D printing and Arduino approaches can provide up to 94% economical savings in hardware and instrumentation in comparison to commercial alternatives. The vast selection of point-of-care-tests (POCT) currently available also limits the need for specific instruments or personnel, as they can be used almost anywhere and by anyone. Lastly, there are dozens of free and libre digital tools available in health informatics. This review provides an overview of the state-of-the-art on cost-effective alternatives with applications in routine clinical pathology laboratories. In this context, a variety of technologies including 3D printing and Arduino, lateral flow assays, plasmonic biosensors, and microfluidics, as well as laboratory information systems, are discussed. This review aims to serve as an introduction to different technologies that can make clinical pathology more accessible and, therefore, contribute to achieve universal health coverage.
Collapse
Affiliation(s)
- Mercedes Vázquez
- National Centre For Sensor Research, School of Chemical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Laura Anfossi
- Department of Chemistry, University of Turin, Via Giuria, 5, I-10125 Turin, Italy
| | - Hadar Ben-Yoav
- Nanobioelectronics Laboratory (NBEL), Department of Biomedical Engineering, Ilse Katz Institute of Nanoscale Science and Technology, Zlotowski Center for Neuroscience, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | - Lorena Diéguez
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory - INL, 4715-330 Braga, Portugal
| | | | - Bartolomeo Della Ventura
- Department of Physics "E. Pancini", University of Naples Federico II, Via Cintia 26, I-80126 Napoli, Italy
| | - Sara Abalde-Cela
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory - INL, 4715-330 Braga, Portugal
| | - Antonio Minopoli
- Department of Physics "E. Pancini", University of Naples Federico II, Via Cintia 26, I-80126 Napoli, Italy
| | - Fabio Di Nardo
- Department of Chemistry, University of Turin, Via Giuria, 5, I-10125 Turin, Italy
| | - Vikas Kumar Shukla
- Nanobioelectronics Laboratory (NBEL), Department of Biomedical Engineering, Ilse Katz Institute of Nanoscale Science and Technology, Zlotowski Center for Neuroscience, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | - Alexandra Teixeira
- Medical Devices Research Group, International Iberian Nanotechnology Laboratory - INL, 4715-330 Braga, Portugal
| | - Asta Tvarijonaviciute
- Interdisciplinary Laboratory of Clinical Pathology, Interlab-UMU, Regional Campus of International Excellence 'Campus Mare Nostrum', University of Murcia, 30100 Murcia, Spain.
| | - Lorena Franco-Martínez
- Interdisciplinary Laboratory of Clinical Pathology, Interlab-UMU, Regional Campus of International Excellence 'Campus Mare Nostrum', University of Murcia, 30100 Murcia, Spain.
| |
Collapse
|
10
|
Yu H, Lee H, Cheong J, Woo SW, Oh J, Oh HK, Lee JH, Zheng H, Castro CM, Yoo YE, Kim MG, Cheon J, Weissleder R, Lee H. A rapid assay provides on-site quantification of tetrahydrocannabinol in oral fluid. Sci Transl Med 2021; 13:eabe2352. [PMID: 34669441 DOI: 10.1126/scitranslmed.abe2352] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
[Figure: see text].
Collapse
Affiliation(s)
- Hojeong Yu
- Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.,Center for Nanomedicine, Institute for Basic Science (IBS), Seoul 03722, South Korea
| | - Hoyeon Lee
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea
| | - Jiyong Cheong
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul 03722, South Korea.,Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul 03722, South Korea
| | - Sang Won Woo
- Department of Nano Manufacturing Technology, Korea Institute of Machinery and Materials, Daejeon 34103, South Korea
| | - Juhyun Oh
- Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Hyun-Kyung Oh
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea
| | - Jae-Hyun Lee
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul 03722, South Korea.,Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul 03722, South Korea
| | - Hui Zheng
- Biostatistics Center, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Cesar M Castro
- Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA.,Department of Medicine, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Yeong-Eun Yoo
- Department of Nano Manufacturing Technology, Korea Institute of Machinery and Materials, Daejeon 34103, South Korea
| | - Min-Gon Kim
- Department of Chemistry, School of Physics and Chemistry, Gwangju Institute of Science and Technology, Gwangju 61005, South Korea
| | - Jinwoo Cheon
- Center for Nanomedicine, Institute for Basic Science (IBS), Seoul 03722, South Korea.,Graduate Program of Nano Biomedical Engineering (NanoBME), Advanced Science Institute, Yonsei University, Seoul 03722, South Korea.,Department of Chemistry, Yonsei University, Seoul 03722, South Korea
| | - Ralph Weissleder
- Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.,Department of Systems Biology, Harvard Medical School, Boston, MA 02115, USA
| | - Hakho Lee
- Center for Systems Biology, Massachusetts General Hospital Research Institute, Boston, MA 02114, USA.,Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| |
Collapse
|
11
|
Ruttanakorn K, Phadungcharoen N, Laiwattanapaisal W, Chinsriwongkul A, Rojanarata T. Smartphone-based technique for the determination of a titration equivalence point from an RGB linear-segment curve with an example application to miniaturized titration of sodium chloride injections. Talanta 2021; 233:122602. [PMID: 34215090 DOI: 10.1016/j.talanta.2021.122602] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2021] [Revised: 06/07/2021] [Accepted: 06/08/2021] [Indexed: 12/29/2022]
Abstract
A smartphone-based technique for determining the titration equivalence point from a linear-segment curve was developed for the first time. In this method, a titrant in an increasing microliter-volume was added to a set of sample aliquots containing an indicator covering both sides of the equivalence point. The solutions were subsequently photographed in one shot, in a dark box using a smartphone camera and an illuminating screen of a tablet or light emitting diode lamps arranged below a white acrylic sheet as a light source. After the colors of the solutions were delineated to Red, Green, and Blue (RGB) values, 1/log G was used to construct a plot in which the equivalence point was located at the intersection of the two lines in the region before and after the equivalence point. The technique was successfully applied to the miniaturized titration of sodium chloride injections, showing the good linear relationship of equivalence points to the sodium chloride concentration in the range of 0.4163-0.9675% w/v (R2 of 0.9998). The assay was accurate (% recovery of 98.92-100.52), precise (% relative standard deviation ≤ 1.20), and unaffected by the use of different types of microplates, smartphones, and RGB analysis tools. Additionally, it required no expensive nor complicated equipment and offered the possibility of performing analysis on a single smartphone device when it was used with a mobile application developed to aid data processing and immediate production of reports of analytical results.
Collapse
Affiliation(s)
- Kanong Ruttanakorn
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand
| | - Noppharat Phadungcharoen
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand
| | - Wanida Laiwattanapaisal
- Biosensors and Bioanalytical Technology for Cells and Innovative Testing Device Research Unit, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | | | - Theerasak Rojanarata
- Pharmaceutical Development of Green Innovations Group (PDGIG) and Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Silpakorn University, Sanam Chandra Palace Campus, Nakhon Pathom, 73000, Thailand.
| |
Collapse
|
12
|
An R, Huang Y, Man Y, Valentine RW, Kucukal E, Goreke U, Sekyonda Z, Piccone C, Owusu-Ansah A, Ahuja S, Little JA, Gurkan UA. Emerging point-of-care technologies for anemia detection. LAB ON A CHIP 2021; 21:1843-1865. [PMID: 33881041 PMCID: PMC8875318 DOI: 10.1039/d0lc01235a] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Anemia, characterized by low blood hemoglobin level, affects about 25% of the world's population with the heaviest burden borne by women and children. Anemia leads to impaired cognitive development in children, as well as high morbidity and early mortality among sufferers. Anemia can be caused by nutritional deficiencies, oncologic treatments and diseases, and infections such as malaria, as well as inherited hemoglobin or red cell disorders. Effective treatments are available for anemia upon early detection and the treatment method is highly dependent on the cause of anemia. There is a need for point-of-care (POC) screening, early diagnosis, and monitoring of anemia, which is currently not widely accessible due to technical challenges and cost, especially in low- and middle-income countries where anemia is most prevalent. This review first introduces the evolution of anemia detection methods followed by their implementation in current commercially available POC anemia diagnostic devices. Then, emerging POC anemia detection technologies leveraging new methods are reviewed. Finally, we highlight the future trends of integrating anemia detection with the diagnosis of relevant underlying disorders to accurately identify specific root causes and to facilitate personalized treatment and care.
Collapse
Affiliation(s)
- Ran An
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Yuning Huang
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Yuncheng Man
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Russell W Valentine
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Erdem Kucukal
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Utku Goreke
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA.
| | - Zoe Sekyonda
- Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA
| | - Connie Piccone
- Department of Pediatric Hematology, Carle Foundation Hospital, Urbana, IL, USA
| | - Amma Owusu-Ansah
- Department of Pediatrics, Division of Hematology and Oncology, University Hospitals Rainbow Babies and Children's Hospital, Case Western Reserve University, Cleveland, OH, USA
| | - Sanjay Ahuja
- Department of Pediatrics, Division of Hematology and Oncology, University Hospitals Rainbow Babies and Children's Hospital, Case Western Reserve University, Cleveland, OH, USA
| | - Jane A Little
- Division of Hematology & UNC Blood Research Center, Department of Medicine, University of North Carolina, Chapel Hill, NC, USA
| | - Umut A Gurkan
- Mechanical and Aerospace Engineering Department, Case Western Reserve University, 10900 Euclid Ave., Glennan Building, Cleveland, OH 44106, USA. and Biomedical Engineering Department, Case Western Reserve University, Cleveland, OH, USA and Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH, USA
| |
Collapse
|
13
|
Fabrication of Microfluidic Devices for Emulsion Formation by Microstereolithography. Molecules 2021; 26:molecules26092817. [PMID: 34068649 PMCID: PMC8126101 DOI: 10.3390/molecules26092817] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/10/2021] [Accepted: 04/27/2021] [Indexed: 01/22/2023] Open
Abstract
Droplet microfluidics—the art and science of forming droplets—has been revolutionary for high-throughput screening, directed evolution, single-cell sequencing, and material design. However, traditional fabrication techniques for microfluidic devices suffer from several disadvantages, including multistep processing, expensive facilities, and limited three-dimensional (3D) design flexibility. High-resolution additive manufacturing—and in particular, projection micro-stereolithography (PµSL)—provides a promising path for overcoming these drawbacks. Similar to polydimethylsiloxane-based microfluidics 20 years ago, 3D printing methods, such as PµSL, have provided a path toward a new era of microfluidic device design. PµSL greatly simplifies the device fabrication process, especially the access to truly 3D geometries, is cost-effective, and it enables multimaterial processing. In this review, we discuss both the basics and recent innovations in PµSL; the material basis with emphasis on custom-made photopolymer formulations; multimaterial 3D printing; and, 3D-printed microfluidic devices for emulsion formation as our focus application. Our goal is to support researchers in setting up their own PµSL system to fabricate tailor-made microfluidics.
Collapse
|
14
|
Development of Rapid and High-Precision Colorimetric Device for Organophosphorus Pesticide Detection Based on Microfluidic Mixer Chip. MICROMACHINES 2021; 12:mi12030290. [PMID: 33803445 PMCID: PMC8000396 DOI: 10.3390/mi12030290] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 03/03/2021] [Accepted: 03/08/2021] [Indexed: 11/17/2022]
Abstract
The excessive pesticide residues in cereals, fruit and vegetables is a big threat to human health, and it is necessary to develop a portable, low-cost and high-precision pesticide residue detection scheme to replace the large-scale laboratory testing equipment for rapid detection of pesticide residues. In this study, a colorimetric device for rapid detection of organophosphorus pesticide residues with high precision based on a microfluidic mixer chip was proposed. The microchannel structure with high mixing efficiency was determined by fluid dynamics simulation, while the corresponding microfluidic mixer chip was designed. The microfluidic mixer chip was prepared by a self-developed liquid crystal display (LCD) mask photo-curing machine. The influence of printing parameters on the accuracy of the prepared chip was investigated. The light source with the optimal wavelength of the device was determined by absorption spectrum measurement, and the relationship between the liquid reservoir depth and detection limit was studied by experiments. The correspondence between pesticide concentration and induced voltage was derived. The minimum detection concentration of the device could reach 0.045 mg·L-1 and the average detection time was reduced to 60 s. The results provide a theoretical and experimental basis for portable and high-precision detection of pesticide residues.
Collapse
|
15
|
Hassan SU, Tariq A, Noreen Z, Donia A, Zaidi SZJ, Bokhari H, Zhang X. Capillary-Driven Flow Microfluidics Combined with Smartphone Detection: An Emerging Tool for Point-of-Care Diagnostics. Diagnostics (Basel) 2020; 10:E509. [PMID: 32708045 PMCID: PMC7459612 DOI: 10.3390/diagnostics10080509] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 07/20/2020] [Accepted: 07/20/2020] [Indexed: 12/20/2022] Open
Abstract
Point-of-care (POC) or near-patient testing allows clinicians to accurately achieve real-time diagnostic results performed at or near to the patient site. The outlook of POC devices is to provide quicker analyses that can lead to well-informed clinical decisions and hence improve the health of patients at the point-of-need. Microfluidics plays an important role in the development of POC devices. However, requirements of handling expertise, pumping systems and complex fluidic controls make the technology unaffordable to the current healthcare systems in the world. In recent years, capillary-driven flow microfluidics has emerged as an attractive microfluidic-based technology to overcome these limitations by offering robust, cost-effective and simple-to-operate devices. The internal wall of the microchannels can be pre-coated with reagents, and by merely dipping the device into the patient sample, the sample can be loaded into the microchannel driven by capillary forces and can be detected via handheld or smartphone-based detectors. The capabilities of capillary-driven flow devices have not been fully exploited in developing POC diagnostics, especially for antimicrobial resistance studies in clinical settings. The purpose of this review is to open up this field of microfluidics to the ever-expanding microfluidic-based scientific community.
Collapse
Affiliation(s)
- Sammer-Ul Hassan
- Bioengineering Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
| | - Aamira Tariq
- Department of Biosciences, Comsats University Islamabad Campus, Islamabad, Pakistan
| | - Zobia Noreen
- Department of Biosciences, Comsats University Islamabad Campus, Islamabad, Pakistan
| | - Ahmed Donia
- Department of Biosciences, Comsats University Islamabad Campus, Islamabad, Pakistan
| | - Syed Z J Zaidi
- Institute of Chemical Engineering and Technology, University of the Punjab, Lahore, Pakistan
| | - Habib Bokhari
- Department of Biosciences, Comsats University Islamabad Campus, Islamabad, Pakistan
| | - Xunli Zhang
- Bioengineering Research Group, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK
- Institute for Life Sciences, University of Southampton, Southampton SO17 1BJ, UK
| |
Collapse
|
16
|
Abstract
The microfluidics field is at a critical crossroads. The vast majority of microfluidic devices are presently manufactured using micromolding processes that work very well for a reduced set of biocompatible materials, but the time, cost, and design constraints of micromolding hinder the commercialization of many devices. As a result, the dissemination of microfluidic technology-and its impact on society-is in jeopardy. Digital manufacturing (DM) refers to a family of computer-centered processes that integrate digital three-dimensional (3D) designs, automated (additive or subtractive) fabrication, and device testing in order to increase fabrication efficiency. Importantly, DM enables the inexpensive realization of 3D designs that are impossible or very difficult to mold. The adoption of DM by microfluidic engineers has been slow, likely due to concerns over the resolution of the printers and the biocompatibility of the resins. In this article, we review and discuss the various printer types, resolution, biocompatibility issues, DM microfluidic designs, and the bright future ahead for this promising, fertile field.
Collapse
Affiliation(s)
- Arman Naderi
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Nirveek Bhattacharjee
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| | - Albert Folch
- Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA;
| |
Collapse
|
17
|
Breheny CR, Kinsey SE, Gow AG. The use of smartphone-obtained images to extrapolate canine packed cell volume. J Vet Emerg Crit Care (San Antonio) 2020; 30:426-435. [PMID: 32543750 DOI: 10.1111/vec.12961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 11/01/2018] [Accepted: 11/24/2018] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To determine whether a smartphone-obtained image can be used to extrapolate the PCV of canine blood samples. DESIGN Prospective study of surplus blood obtained from clinical cases. SETTING University teaching hospital. INTERVENTIONS Blood samples were placed on filter paper, and images were obtained with a smartphone in different environments. These results were then compared to the PCV measurements on the same samples following the World Health Organization guidelines. MEASUREMENTS Sixty-nine samples were assessed and identified that smartphone images, obtained in a controlled environment, were able to predict the PCV of the samples. This prediction was most accurate when assessing samples of a normal erythroid mass or polycythemic samples. CONCLUSIONS The results of this study suggest that smartphone-obtained images do have a utility in predicting canine PCV. If this can be incorporated into a smartphone application, there would be scope to use this in low resource settings.
Collapse
Affiliation(s)
- Craig R Breheny
- Royal (Dick) School of Veterinary Studies, Midlothian, Scotland
| | | | - Adam G Gow
- Royal (Dick) School of Veterinary Studies, Midlothian, Scotland
| |
Collapse
|
18
|
Nielsen AV, Beauchamp MJ, Nordin GP, Woolley AT. 3D Printed Microfluidics. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2020; 13:45-65. [PMID: 31821017 PMCID: PMC7282950 DOI: 10.1146/annurev-anchem-091619-102649] [Citation(s) in RCA: 143] [Impact Index Per Article: 35.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Traditional microfabrication techniques suffer from several disadvantages, including the inability to create truly three-dimensional (3D) architectures, expensive and time-consuming processes when changing device designs, and difficulty in transitioning from prototyping fabrication to bulk manufacturing. 3D printing is an emerging technique that could overcome these disadvantages. While most 3D printed fluidic devices and features to date have been on the millifluidic size scale, some truly microfluidic devices have been shown. Currently, stereolithography is the most promising approach for routine creation of microfluidic structures, but several approaches under development also have potential. Microfluidic 3D printing is still in an early stage, similar to where polydimethylsiloxane was two decades ago. With additional work to advance printer hardware and software control, expand and improve resin and printing material selections, and realize additional applications for 3D printed devices, we foresee 3D printing becoming the dominant microfluidic fabrication method.
Collapse
Affiliation(s)
- Anna V Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, USA;
| | - Michael J Beauchamp
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, USA;
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, Utah 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602, USA;
| |
Collapse
|
19
|
Chakraborty S, Das S, Das C, Chandra S, Sharma KD, Karmakar A, Chattoapadhyay S. On-chip estimation of hematocrit level for diagnosing anemic conditions by Impedimetric techniques. Biomed Microdevices 2020; 22:38. [PMID: 32430696 DOI: 10.1007/s10544-020-00493-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
An on-chip device has been fabricated on Si platform for precise estimation of the hematocrit (Hct) level of human blood with rapid turn out. Impedance/capacitance spectroscopy and current-voltage (I-V) measurements have been employed to observe the variation of electrical parameters of erythrocyte suspensions with varying Hct level. Experimentally obtained values of capacitance, impedance and conductance with Hct level suggests a linear variation. Current-time measurement has also been performed to ensure the susceptibility of red blood cells under a fixed external electric field for certain duration of time. The online real time sample analyzes have also been performed by the device connected with an embedded electronic circuit interfaced with a laptop through appropriate software. This has enabled the development of a novel Si-chip based compact point-of-care (POC) diagnosis system for Hct level estimation by measuring the dielectric/capacitive variation of an erythrocyte cell suspension. The relevant performance parameters of such a compact system including range, resolution, limit of detection and throughput have also been evaluated.
Collapse
Affiliation(s)
- Subhadip Chakraborty
- Department of Electronic Science, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Sreyasi Das
- Department of Physiology, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Chirantan Das
- Department of Electronic Science, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Soumyak Chandra
- Department of Applied Physics, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Kaushik Das Sharma
- Department of Applied Physics, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Anupam Karmakar
- Department of Electronic Science, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India
| | - Sanatan Chattoapadhyay
- Department of Electronic Science, University of Calcutta, 92 A.P.C. Road, Kolkata, 700009, India.
| |
Collapse
|
20
|
Shrivastava S, Trung TQ, Lee NE. Recent progress, challenges, and prospects of fully integrated mobile and wearable point-of-care testing systems for self-testing. Chem Soc Rev 2020; 49:1812-1866. [PMID: 32100760 DOI: 10.1039/c9cs00319c] [Citation(s) in RCA: 207] [Impact Index Per Article: 51.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The rapid growth of research in the areas of chemical and biochemical sensors, lab-on-a-chip, mobile technology, and wearable electronics offers an unprecedented opportunity in the development of mobile and wearable point-of-care testing (POCT) systems for self-testing. Successful implementation of such POCT technologies leads to minimal user intervention during operation to reduce user errors; user-friendly, easy-to-use and simple detection platforms; high diagnostic sensitivity and specificity; immediate clinical assessment; and low manufacturing and consumables costs. In this review, we discuss recent developments in the field of highly integrated mobile and wearable POCT systems. In particular, aspects of sample handling platforms, recognition elements and sensing methods, and new materials for signal transducers and powering devices for integration into mobile or wearable POCT systems will be highlighted. We also summarize current challenges and future prospects for providing personal healthcare with sample-in result-out mobile and wearable POCT.
Collapse
Affiliation(s)
- Sajal Shrivastava
- School of Advanced Materials Science & Engineering, Sungkyunkwan University, Suwon, Gyeonggi-do 16419, Korea.
| | | | | |
Collapse
|
21
|
Karayannis P, Petrakli F, Gkika A, Koumoulos EP. 3D-Printed Lab-on-a-Chip Diagnostic Systems-Developing a Safe-by-Design Manufacturing Approach. MICROMACHINES 2019; 10:E825. [PMID: 31795128 PMCID: PMC6969929 DOI: 10.3390/mi10120825] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 11/13/2019] [Accepted: 11/25/2019] [Indexed: 12/12/2022]
Abstract
The aim of this study is to provide a detailed strategy for Safe-by-Design (SbD) 3D-printed lab-on-a-chip (LOC) device manufacturing, using Fused Filament Fabrication (FFF) technology. First, the applicability of FFF in lab-on-a-chip device development is briefly discussed. Subsequently, a methodology to categorize, identify and implement SbD measures for FFF is suggested. Furthermore, the most crucial health risks involved in FFF processes are examined, placing the focus on the examination of ultrafine particle (UFP) and Volatile Organic Compound (VOC) emission hazards. Thus, a SbD scheme for lab-on-a-chip manufacturing is provided, while also taking into account process optimization for obtaining satisfactory printed LOC quality. This work can serve as a guideline for the effective application of FFF technology for lab-on-a-chip manufacturing through the safest applicable way, towards a continuous effort to support sustainable development of lab-on-a-chip devices through cost-effective means.
Collapse
Affiliation(s)
| | | | | | - Elias P. Koumoulos
- Innovation in Research & Engineering Solutions (IRES), Boulevard Edmond Machtens 79/22, 1080 Brussels, Belgium; (P.K.); (F.P.); (A.G.)
| |
Collapse
|
22
|
Zhu Q, Hamilton M, Vasquez B, He M. 3D-printing enabled micro-assembly of a microfluidic electroporation system for 3D tissue engineering. LAB ON A CHIP 2019; 19:2362-2372. [PMID: 31214669 PMCID: PMC6636854 DOI: 10.1039/c9lc00046a] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Electro-transfection is an essential workhorse tool for regulating cellular responses and engineering cellular materials in tissue engineering. However, most of the existing approaches are only focused on cell suspensions in vitro, which fails to mimic an in vivo tissue microenvironment regarding the 3D electric field distribution and mass transport in a biological matrix. However, building a 3D electro-transfection system that is compatible with 3D cell culture for mimicking the in vivo tissue microenvironment is challenging, due to the substantial difficulties in control of the 3D electric field distribution as well as the cellular growth. To address such challenges, we introduce a novel 3D micro-assembly strategy assisted by 3D printing, which enables the molding of 3D microstructures as LEGO® parts from 3D-printed molds. The molded PDMS LEGO® bricks are then assembled into a 3D-cell culture chamber interconnected with vertical and horizontal perfusion microchannels as a 3D channel network. Such a 3D perfusion microchannel network is unattainable by direct 3D printing or other microfabrication approaches, which can facilitate the highly-efficient exchange of nutrition and waste for 3D cell growth. Four flat electrodes are mounted into the 3D culture chamber via a 3D-printed holder and controlled by a programmable power sequencer for multi-directional electric frequency scanning (3D μ-electro-transfection). This multi-directional scanning not only can create transient pores all over the cell membrane, but also can generate local oscillation for enhancing mass transport and improving cell transfection efficiency. As a proof-of-concept, we electro-delivered the pAcGFP1-C1 vector to 3D cultured HeLa cells within peptide hydrogel scaffolding. The expressed GFP level from transfected HeLa cells reflects the transfection efficiency. We found two key parameters including electric field strength and plasmid concentration playing more important roles than the pulse duration and duty cycles. The results showed an effective transfection efficiency of ∼15% with ∼85% cell viability, which is 3-fold higher compared to that of the conventional benchtop 3D cell electro-transfection. This 3D μ-electrotransfection system was further used for genetically editing 3D-cultured Hek-293 cells via direct delivery of CRISPR/Cas9 plasmid which showed successful transfection with GFP expressed in the cytoplasm as the reporter. The 3D-printing enabled micro-assembly allows facile creation of a novel 3D culture system for electro-transfection, which can be employed for versatile gene delivery and cellular engineering, as well as building in vivo like tissue models for fundamentally studying cellular regulation mechanisms at the molecular level.
Collapse
Affiliation(s)
- Qingfu Zhu
- Department of Chemical and Petroleum Engineering, Bioengineering Program, University of Kansas, Lawrence, Kansas, USA.
| | | | | | | |
Collapse
|
23
|
Beauchamp MJ, Nielsen AV, Gong H, Nordin GP, Woolley AT. 3D Printed Microfluidic Devices for Microchip Electrophoresis of Preterm Birth Biomarkers. Anal Chem 2019; 91:7418-7425. [PMID: 31056901 PMCID: PMC6561337 DOI: 10.1021/acs.analchem.9b01395] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This work demonstrates for the first time the creation of microchip electrophoresis devices with ∼50 μm cross-sectional dimensions by stereolithographic 3D printing and their application in the analysis of medically significant biomarkers related to risk for preterm birth (PTB). We determined that device current was linear with applied potential up to 800 V (620 V/cm). We optimized device and separation conditions using fluorescently labeled amino acids as a model system and compared the performance in our 3D printed microfluidic devices to that in other device materials commonly used for microchip electrophoresis analysis. We demonstrated for the first time microchip electrophoresis in a 3D printed device of three PTB biomarkers, including peptides and a protein, with suitable separation characteristics. Limits of detection for microchip electrophoresis in 3D printed microfluidic devices were also determined for PTB biomarkers to be in the high picomolar to low nanomolar range.
Collapse
Affiliation(s)
- Michael J. Beauchamp
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Anna V. Nielsen
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| | - Hua Gong
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Gregory P. Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Adam T. Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT, 84602, USA
| |
Collapse
|
24
|
Michalec M, Koncki R, Tymecki Ł. Optoelectronic detectors for flow analysis systems manufactured by means of rapid prototyping technology. Talanta 2019; 198:169-178. [PMID: 30876546 DOI: 10.1016/j.talanta.2019.01.092] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 01/22/2019] [Accepted: 01/24/2019] [Indexed: 10/27/2022]
Abstract
Universal, customizable design of 3D printed photometric, and fluorometric flow-through detectors have been presented. The developed designs were fabricated with the use of the most affordable 3D printing technique, namely Fused Filament Fabrication, and require neither hardware nor tools to assemble. Numerous variants of detector geometries have also been presented. The designed parameters varied both in aperture (i.e., the internal diameter of the flow channel in an optical path) and in thickness of an absorbing layer. As expected, the geometry of the channels resulted in changes in the internal volumes. Two concepts of fluorometric detectors have also been described. The utility of all developed flow-through detectors was proven with the use of mechanized calibrations of both photometric and fluorometric experiments. Analytical parameters were characterized with the use of two model dyes: bromothymol blue and fluorescein for photometric and fluorometric experiments, respectively. The repeatability of the 3D printed vessels was found at 3.5-8.0% of the mean relative standard deviation (RSD), depending on the construction of the vessel, which is comparable to rather expensive commercially available flow cells. The compatibility of used 3D printing materials was also examined. For both variants of detection light emitting diodes were applied as light emitters. As the light detectors, both CCD spectrophotometers and light-emitting diodes were used.
Collapse
Affiliation(s)
- Michał Michalec
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw, Poland; University of Warsaw, MISMaP College, Banacha 2C, 02-097 Warsaw, Poland
| | - Robert Koncki
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw, Poland
| | - Łukasz Tymecki
- University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093 Warsaw, Poland.
| |
Collapse
|
25
|
Christodouleas DC, Kaur B, Chorti P. From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics). ACS CENTRAL SCIENCE 2018; 4:1600-1616. [PMID: 30648144 PMCID: PMC6311959 DOI: 10.1021/acscentsci.8b00625] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Indexed: 05/09/2023]
Abstract
Point-of-care devices were originally designed to allow medical testing at or near the point of care by health-care professionals. Some point-of-care devices allow medical self-testing at home but cannot fully cover the growing diagnostic needs of eHealth systems that are under development in many countries. A number of easy-to-use, network-connected diagnostic devices for self-testing are needed to allow remote monitoring of patients' health. This Outlook highlights the essential characteristics of diagnostic devices for eHealth settings and indicates point-of-care technologies that may lead to the development of new devices. It also describes the most representative examples of simple-to-use, point-of-care devices that have been used for analysis of untreated biological samples.
Collapse
Affiliation(s)
| | - Balwinder Kaur
- Department of Chemistry, University
of Massachusetts Lowell, Lowell, Massachusetts 01854, United States
| | - Parthena Chorti
- Department of Chemistry, University
of Massachusetts Lowell, Lowell, Massachusetts 01854, United States
| |
Collapse
|
26
|
Li F, Macdonald NP, Guijt RM, Breadmore MC. Increasing the functionalities of 3D printed microchemical devices by single material, multimaterial, and print-pause-print 3D printing. LAB ON A CHIP 2018; 19:35-49. [PMID: 30475367 DOI: 10.1039/c8lc00826d] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
3D printing has emerged as a valuable approach for the fabrication of fluidic devices and may replace soft-lithography as the method of choice for rapid prototyping. The potential of this disruptive technology is much greater than this - it allows for functional integration in a single, highly automated manufacturing step in a cost and time effective manner. Integration of functionality with a 3D printer can be done through spatial configuration of a single material, inserting pre-made components mid-print in a print-pause-print approach, and/or through the precise spatial deposition of different materials with a multimaterial printer. This review provides an overview on the ways in which 3D printing has been exploited to create and use fluidic devices with different functionality, which provides a basis for critical reflection on the current deficiencies and future opportunities for integration by 3D printing.
Collapse
Affiliation(s)
- Feng Li
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| | - Niall P Macdonald
- Analytical-Chemistry Group, van't Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands and Vrije Universiteit Amsterdam, Division of BioAnalytical Chemistry, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands
| | - Rosanne M Guijt
- Deakin University, Centre for Rural and Regional Futures, Private Bag 20000, 3220 Geelong, Australia
| | - Michael C Breadmore
- Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
| |
Collapse
|
27
|
Dixit C, Kadimisetty K, Rusling J. 3D-printed miniaturized fluidic tools in chemistry and biology. Trends Analyt Chem 2018; 106:37-52. [PMID: 32296252 PMCID: PMC7158885 DOI: 10.1016/j.trac.2018.06.013] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
3D printing (3DP), an additive manufacturing (AM) approach allowing for rapid prototyping and decentralized fabrication on-demand, has become a common method for creating parts or whole devices. The wide scope of the AM extends from organized sectors of construction, ornament, medical, and R&D industries to individual explorers attributed to the low cost, high quality printers along with revolutionary tools and polymers. While progress is being made but big manufacturing challenges are still there. Considering the quickly shifting narrative towards miniaturized analytical systems (MAS) we focus on the development/rapid prototyping and manufacturing of MAS with 3DP, and application dependent challenges in engineering designs and choice of the polymeric materials and provide an exhaustive background to the applications of 3DP in biology and chemistry. This will allow readers to perceive the most important features of AM in creating (i) various individual and modular components, and (ii) complete integrated tools.
Collapse
Affiliation(s)
- C.K. Dixit
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - K. Kadimisetty
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
| | - J. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, United States
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, United States
- Department of Surgery and Neag Cancer Centre, UConn Health, Farmington, CT 06030, United States
- School of Chemistry, National University of Ireland at Galway, Galway, Ireland
| |
Collapse
|
28
|
Yap BK, M Soair SN, Talik NA, Lim WF, Mei I L. Potential Point-of-Care Microfluidic Devices to Diagnose Iron Deficiency Anemia. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2625. [PMID: 30103424 PMCID: PMC6111990 DOI: 10.3390/s18082625] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 07/18/2018] [Accepted: 07/18/2018] [Indexed: 12/20/2022]
Abstract
Over the past 20 years, rapid technological advancement in the field of microfluidics has produced a wide array of microfluidic point-of-care (POC) diagnostic devices for the healthcare industry. However, potential microfluidic applications in the field of nutrition, specifically to diagnose iron deficiency anemia (IDA) detection, remain scarce. Iron deficiency anemia is the most common form of anemia, which affects billions of people globally, especially the elderly, women, and children. This review comprehensively analyzes the current diagnosis technologies that address anemia-related IDA-POC microfluidic devices in the future. This review briefly highlights various microfluidics devices that have the potential to detect IDA and discusses some commercially available devices for blood plasma separation mechanisms. Reagent deposition and integration into microfluidic devices are also explored. Finally, we discuss the challenges of insights into potential portable microfluidic systems, especially for remote IDA detection.
Collapse
Affiliation(s)
- Boon Kar Yap
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Siti Nur'Arifah M Soair
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Noor Azrina Talik
- Electronics and Communication Department, College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
- Institute of Power Electronics (IPE), College of Engineering, Universiti Tenaga Nasional, KM-7 Jalan Uniten-Ikram, 43000 Kajang, Selangor, Malaysia.
| | - Wai Feng Lim
- Integrative Pharmacogenomics Institute (iPROMISE), Universiti Teknologi MARA Selangor, Puncak Alam Campus, 42300 Bandar Puncak Alam, Selangor, Malaysia.
| | - Lai Mei I
- Department of Pathology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia.
| |
Collapse
|
29
|
Sharafeldin M, Jones A, Rusling JF. 3D-Printed Biosensor Arrays for Medical Diagnostics. MICROMACHINES 2018; 9:E394. [PMID: 30424327 PMCID: PMC6187244 DOI: 10.3390/mi9080394] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 07/20/2018] [Accepted: 08/02/2018] [Indexed: 11/23/2022]
Abstract
While the technology is relatively new, low-cost 3D printing has impacted many aspects of human life. 3D printers are being used as manufacturing tools for a wide variety of devices in a spectrum of applications ranging from diagnosis to implants to external prostheses. The ease of use, availability of 3D-design software and low cost has made 3D printing an accessible manufacturing and fabrication tool in many bioanalytical research laboratories. 3D printers can print materials with varying density, optical character, strength and chemical properties that provide the user with a vast array of strategic options. In this review, we focus on applications in biomedical diagnostics and how this revolutionary technique is facilitating the development of low-cost, sensitive, and often geometrically complex tools. 3D printing in the fabrication of microfluidics, supporting equipment, and optical and electronic components of diagnostic devices is presented. Emerging diagnostics systems using 3D bioprinting as a tool to incorporate living cells or biomaterials into 3D printing is also reviewed.
Collapse
Affiliation(s)
- Mohamed Sharafeldin
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, CT 06269, USA.
- Analytical Chemistry Department, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Sharkia, Egypt.
| | - Abby Jones
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, CT 06269, USA.
| | - James F Rusling
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, CT 06269, USA.
- Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Storrs, CT 06269, USA.
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, CT 06032, USA.
- School of Chemistry, National University of Ireland, Galway, University Road, Galway, Ireland.
| |
Collapse
|
30
|
Beauchamp MJ, Gong H, Woolley AT, Nordin GP. 3D Printed Microfluidic Features Using Dose Control in X, Y, and Z Dimensions. MICROMACHINES 2018; 9:E326. [PMID: 30424259 PMCID: PMC6082287 DOI: 10.3390/mi9070326] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 06/25/2018] [Accepted: 06/26/2018] [Indexed: 12/12/2022]
Abstract
Interest has grown in recent years to leverage the possibilities offered by three-dimensional (3D) printing, such as rapid iterative changes; the ability to more fully use 3D device volume; and ease of fabrication, especially as it relates to the creation of complex microfluidic devices. A major shortcoming of most commercially available 3D printers is that their resolution is not sufficient to produce features that are truly microfluidic (<100 × 100 μm²). Here, we test a custom 3D printer for making ~30 μm scale positive and negative surface features, as well as positive and negative features within internal voids (i.e., microfluidic channels). We found that optical dosage control is essential for creating the smallest microfluidic features (~30 µm wide for ridges, ~20 µm wide for trenches), and that this resolution was achieved for a number of different exposure approaches. Additionally, we printed various microfluidic particle traps, showed capture of 25 µm diameter polymer beads, and iteratively improved the trap design. The rapid feedback allowed by 3D printing, as well as the ability to carefully control optical exposure conditions, should lead to new innovations in the types and sizes of devices that can be created for microfluidics.
Collapse
Affiliation(s)
- Michael J Beauchamp
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
| | - Hua Gong
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA.
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA.
| |
Collapse
|
31
|
Zhu Q, Heon M, Zhao Z, He M. Microfluidic engineering of exosomes: editing cellular messages for precision therapeutics. LAB ON A CHIP 2018; 18:1690-1703. [PMID: 29780982 PMCID: PMC5997967 DOI: 10.1039/c8lc00246k] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Study of extracellular vesicles (EVs), particularly exosomes, holds significant promise; however, it is technically challenging to define these small and molecularly diverse nanovesicles. With intrinsic molecular payload and biodegradability, molecular engineering of exosomes opens new avenues for mediating cellular responses and developing novel nano-delivery systems in precision therapeutics. Microfluidic lab-on-chip technology is playing pivotal roles in this emerging field. In this review, we have examined scientific advancements of microfluidic technology for engineering exosomes and assessed future applications and perspectives in developing precision therapeutics; this can serve the community via identification of potential new research areas or technologies that are urgently needed in precision therapeutics.
Collapse
Affiliation(s)
- Qingfu Zhu
- Department of Chemical and Petroleum Engineering, University of Kansas, Lawrence, Kansas 66045, USA.
| | | | | | | |
Collapse
|
32
|
3D Printing Solutions for Microfluidic Chip-To-World Connections. MICROMACHINES 2018; 9:mi9020071. [PMID: 30393347 PMCID: PMC6187806 DOI: 10.3390/mi9020071] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 01/30/2018] [Accepted: 02/03/2018] [Indexed: 11/25/2022]
Abstract
The connection of microfluidic devices to the outer world by tubes and wires is an underestimated issue. We present methods based on 3D printing to realize microfluidic chip holders with reliable fluidic and electric connections. The chip holders are constructed by microstereolithography, an additive manufacturing technique with sub-millimeter resolution. The fluidic sealing between the chip and holder is achieved by placing O-rings, partly integrated into the 3D-printed structure. The electric connection of bonding pads located on microfluidic chips is realized by spring-probes fitted within the printed holder. Because there is no gluing or wire bonding necessary, it is easy to change the chip in the measurement setup. The spring probes and O-rings are aligned automatically because of their fixed position within the holder. In the case of bioanalysis applications such as cells, a limitation of 3D-printed objects is the leakage of cytotoxic residues from the printing material, cured resin. This was solved by coating the 3D-printed structures with parylene-C. The combination of silicon/glass microfluidic chips fabricated with highly-reliable clean-room technology and 3D-printed chip holders for the chip-to-world connection is a promising solution for applications where biocompatibility, optical transparency and accurate sample handling must be assured. 3D printing technology for such applications will eventually arise, enabling the fabrication of complete microfluidic devices.
Collapse
|
33
|
Yan S, Zhu Y, Tang SY, Li Y, Zhao Q, Yuan D, Yun G, Zhang J, Zhang S, Li W. A rapid, maskless 3D prototyping for fabrication of capillary circuits: Toward urinary protein detection. Electrophoresis 2018; 39:957-964. [PMID: 29292831 DOI: 10.1002/elps.201700449] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 12/21/2017] [Accepted: 12/21/2017] [Indexed: 01/18/2023]
Abstract
Proteinuria is an established risk marker for progressive renal function loss and patients would significantly benefit from a point-of-care testing. Although extensive work has been done to develop the microfluidic devices for the detection of urinary protein, they need the complicated operation and bulky peripherals. Here, we present a rapid, maskless 3D prototyping for fabrication of capillary fluidic circuits using laser engraving. The capillary circuits can be fabricated in a short amount of time (<10 min) without the requirements of clean-room facilities and photomasks. The advanced capillary components (e.g., trigger valves, retention valves and retention bursting valves) were fabricated, enabling the sequential liquid delivery and sample-reagent mixing. With the integration of smartphone-based detection platform, the microfluidic device can quantify the urinary protein via a colorimetric analysis. By eliminating the bulky and expensive equipment, this smartphone-based detection platform is portable for on-site quantitative detection.
Collapse
Affiliation(s)
- Sheng Yan
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Yuanqing Zhu
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, P. R. China
| | - Shi-Yang Tang
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Yuxing Li
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Qianbin Zhao
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Dan Yuan
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Guolin Yun
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| | - Jun Zhang
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing, P. R. China
| | - Shiwu Zhang
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, P. R. China
| | - Weihua Li
- School of Mechanical, Materials and Mechatronic Engineering, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
34
|
Advances in point-of-care technologies for molecular diagnostics. Biosens Bioelectron 2017; 98:494-506. [DOI: 10.1016/j.bios.2017.07.024] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/06/2017] [Accepted: 07/10/2017] [Indexed: 12/31/2022]
|
35
|
Lønning PE. Comment on "Towards a personalized approach to aromatase inhibitor therapy: a digital microfluidic platform for rapid analysis of estradiol in core-needle-biopsies" by S. Abdulwahab, A. H. C. Ng, M. D. Chamberlain, H. Ahmado, L.-A. Behan, H. Gomaa, R. F. Casper and A. R. Wheeler, Lab Chip, 2017, 17, 1594. LAB ON A CHIP 2017; 17:1594-1602. [PMID: 28816306 DOI: 10.1039/c7lc00170c] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This comment on an article that appeared in Lab on a Chip (Abdulwahab et al., Lab Chip, 2017, 17, 1594) highlights the need for further validation of the proposed method.
Collapse
Affiliation(s)
- Per E Lønning
- Department of Clinical Science, Faculty of Medicine, University of Bergen and Department of Oncology, Haukeland University Hospital, Bergen, Norway.
| |
Collapse
|
36
|
Kadilak AL, Rehaag JC, Harrington CA, Shor LM. A 3D-printed microbial cell culture platform with in situ PEGDA hydrogel barriers for differential substrate delivery. BIOMICROFLUIDICS 2017; 11:054109. [PMID: 29034053 PMCID: PMC5624803 DOI: 10.1063/1.5003477] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Accepted: 09/06/2017] [Indexed: 05/05/2023]
Abstract
Additive manufacturing, or 3D-printing techniques have recently begun to enable simpler, faster, and cheaper production of millifluidic devices at resolutions approaching 100-200 μm. At this resolution, cell culture devices can be constructed that more accurately replicate natural environments compared with conventional culturing techniques. A number of microfluidics researchers have begun incorporating additive manufacturing into their work, using 3D-printed devices in a wide array of chemical, fluidic, and even some biological applications. Here, we describe a 3D-printed cell culture platform and demonstrate its use in culturing Pseudomonas putida KT2440 bacteria for 44 h under a differential substrate gradient. Polyethylene glycol diacrylate (PEGDA) hydrogel barriers are patterned in situ within a 3D-printed channel. Transport of the toluidine blue tracer dye through the hydrogel barriers is characterized. Nutrients and oxygen were delivered to cells in the culture region by diffusion through the PEGDA hydrogel barriers from adjacent media or saline perfusion channels. Expression of green fluorescent protein by P. putida KT2440 enabled real time visualization of cell density within the 3D-printed channel, and demonstrated cells were actively expressing protein over the course of the experiment. Cells were observed clustering near hydrogel barrier boundaries where fresh substrate and oxygen were being delivered via diffusive transport, but cells were unable to penetrate the barrier. The device described here provides a versatile and easy to implement platform for cell culture in readily controlled gradient microenvironments. By adjusting device geometry and hydrogel properties, this platform could be further customized for a wide variety of biological applications.
Collapse
Affiliation(s)
- Andrea L Kadilak
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, Connecticut 06269-3222, USA
| | - Jessica C Rehaag
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, Connecticut 06269-3222, USA
| | - Cameron A Harrington
- Department of Chemical and Biomolecular Engineering, University of Connecticut, Storrs, Connecticut 06269-3222, USA
| | | |
Collapse
|
37
|
Chan HN, Tan MJA, Wu H. Point-of-care testing: applications of 3D printing. LAB ON A CHIP 2017; 17:2713-2739. [PMID: 28702608 DOI: 10.1039/c7lc00397h] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.
Collapse
Affiliation(s)
- Ho Nam Chan
- Department of Chemistry, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong, China.
| | | | | |
Collapse
|
38
|
Amin R, Knowlton S, Dupont J, Bergholz JS, Joshi A, Hart A, Yenilmez B, Yu CH, Wentworth A, Zhao JJ, Tasoglu S. 3D-printed smartphone-based device for label-free cell separation. ACTA ACUST UNITED AC 2017. [DOI: 10.2217/3dp-2016-0007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Aim: To assess several fabrication metrics of a 3D-printed smartphone-attachable continuous-flow magnetic focusing device for real-time separation and detection of different cell types based on their volumetric mass density in high-volume samples. Method: The smartphone apparatus has been designed and fabricated using three different 3D printing method. Several 3D printing metrics including cost, printing time, and resolution have been evaluated to propose a cost-efficient and high-performance platform for low-resource settings. Results: To apply the magnetic focusing technique on large sample volumes, a heterogeneous mixture of sample (e.g., containing blood cells and cancer cells) suspended in paramagnetic medium is pumped through a magnetic field at an optimum flow rate. The performance of the 3D-printed device has been investigated by demonstrating separation of microspheres, breast, lung, ovarian and prostate cancer cells mixed with blood cells. The separation distance of cancer and blood cells is around 100 μm, allowing the two cell types to be easily distinguished. Conclusion: This device could be useful for clinical centers in low-income countries where expensive infrastructure, equipment (e.g., FACS) and technical expertise are lacking. This device could ultimately be applied to rare cell separation and purification.
Collapse
Affiliation(s)
- Reza Amin
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Stephanie Knowlton
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Joshua Dupont
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Johann S Bergholz
- Department of Cancer Biology, Dana-Farber Cancer Institute, Boston, MA 02215, USA; Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, Boston, MA 02115, USA
| | - Ashwini Joshi
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Alexander Hart
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Bekir Yenilmez
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Chu Hsiang Yu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Adam Wentworth
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269, USA
| | - Jean J Zhao
- Department of Cancer Biology, Dana-Farber Cancer Institute, Boston, MA 02215, USA; Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, Boston, MA 02115, USA
| | - Savas Tasoglu
- Department of Mechanical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269, USA
- Institute for Collaboration on Health, Intervention, & Policy, University of Connecticut, Storrs, CT 06269, USA
| |
Collapse
|
39
|
Beauchamp MJ, Nordin GP, Woolley AT. Moving from millifluidic to truly microfluidic sub-100-μm cross-section 3D printed devices. Anal Bioanal Chem 2017; 409:4311-4319. [PMID: 28612085 DOI: 10.1007/s00216-017-0398-3] [Citation(s) in RCA: 66] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2017] [Revised: 04/28/2017] [Accepted: 05/05/2017] [Indexed: 12/20/2022]
Abstract
Three-dimensional (3D) printing has generated considerable excitement in recent years regarding the extensive possibilities of this enabling technology. One area in which 3D printing has potential, not only for positive impact but also for substantial improvement, is microfluidics. To date many researchers have used 3D printers to make fluidic channels directed at point-of-care or lab-on-a-chip applications. Here, we look critically at the cross-sectional sizes of these 3D printed fluidic structures, classifying them as millifluidic (larger than 1 mm), sub-millifluidic (0.5-1.0 mm), large microfluidic (100-500 μm), or truly microfluidic (smaller than 100 μm). Additionally, we provide our prognosis for making 10-100-μm cross-section microfluidic features with custom-formulated resins and stereolithographic printers. Such 3D printed microfluidic devices for bioanalysis will accelerate research through designs that can be easily created and modified, allowing improved assays to be developed.
Collapse
Affiliation(s)
- Michael J Beauchamp
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, Brigham Young University, C100 BNSN, Provo, UT, 84602, USA.
| |
Collapse
|
40
|
Nayak S, Blumenfeld NR, Laksanasopin T, Sia SK. Point-of-Care Diagnostics: Recent Developments in a Connected Age. Anal Chem 2017; 89:102-123. [PMID: 27958710 PMCID: PMC5793870 DOI: 10.1021/acs.analchem.6b04630] [Citation(s) in RCA: 281] [Impact Index Per Article: 40.1] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Affiliation(s)
- Samiksha Nayak
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, NY 10027, USA
| | - Nicole R. Blumenfeld
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, NY 10027, USA
| | - Tassaneewan Laksanasopin
- Biological Engineering Program, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand
| | - Samuel K. Sia
- Department of Biomedical Engineering, Columbia University, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, NY 10027, USA
| |
Collapse
|