1
|
Kandwal A, Sharma YD, Jasrotia R, Kit CC, Lakshmaiya N, Sillanpää M, Liu LW, Igbe T, Kumari A, Sharma R, Kumar S, Sungoum C. A comprehensive review on electromagnetic wave based non-invasive glucose monitoring in microwave frequencies. Heliyon 2024; 10:e37825. [PMID: 39323784 PMCID: PMC11422007 DOI: 10.1016/j.heliyon.2024.e37825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 08/06/2024] [Accepted: 09/10/2024] [Indexed: 09/27/2024] Open
Abstract
Diabetes is a chronic disease that affects millions of humans worldwide. This review article provides an analysis of the recent advancements in non-invasive blood glucose monitoring, detailing methods and techniques, with a special focus on Electromagnetic wave microwave glucose sensors. While optical, thermal, and electromagnetic techniques have been discussed, the primary emphasis is focussed on microwave frequency sensors due to their distinct advantages. Microwave sensors exhibit rapid response times, require minimal user intervention, and hold potential for continuous monitoring, renders them extremely potential for real-world applications. Additionally, their reduced susceptibility to physiological interferences further enhances their appeal. This review critically assesses the performance of microwave glucose sensors by considering factors such as accuracy, sensitivity, specificity, and user comfort. Moreover, it sheds light on the challenges and upcoming directions in the growth of microwave sensors, including the need for reduction and integration with wearable platforms. By concentrating on microwave sensors within the broader context of non-invasive glucose monitoring, this article aims to offer significant enlightenment that may drive further innovation in diabetes care.
Collapse
Affiliation(s)
- Abhishek Kandwal
- School of Chips, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, Taicang, Suzhou 215400, China
- Faculty of Engineering and Quantity Surveying, INTI International University, Nilai, 71800, Malaysia
- School of Physics and Materials Science, Shoolini University, Bajhol, Himachal Pradesh, 173229, India
| | - Yogeshwar Dutt Sharma
- School of Physics and Materials Science, Shoolini University, Bajhol, Himachal Pradesh, 173229, India
| | - Rohit Jasrotia
- Faculty of Engineering and Quantity Surveying, INTI International University, Nilai, 71800, Malaysia
- School of Physics and Materials Science, Shoolini University, Bajhol, Himachal Pradesh, 173229, India
- Centre for Research Impact and Outcome, Chitkara University, Rajpura 140101, Punjab, India
| | - Chan Choon Kit
- Faculty of Engineering and Quantity Surveying, INTI International University, Nilai, 71800, Malaysia
- Faculty of Engineering, Shinawatra University, Pathumthani, 12160, Thailand
| | - Natrayan Lakshmaiya
- Department of Research and Innovation, Saveetha School of Engineering, SIMATS, Chennai, Tamil Nadu 602105, India
| | - Mika Sillanpää
- Functional Materials Group, Gulf University for Science and Technology, Mubarak Al-Abdullah, 32093, Kuwait
- Department of Chemical Engineering, School of Mining, Metallurgy and Chemical Engineering, Uni-versity of Johannesburg, P. O. Box 17011, Doornfontein 2028, South Africa
- Sustainability Cluster, School of Advanced Engineering, UPES, Bidholi, Dehradun, Uttarakhand 248007, India
- School of Technology, Woxsen University, Hyderabad, Telangana, India
| | - Louis Wy Liu
- Faculty of Engineering, Vietnamese German University, 75000, Viet Nam
| | - Tobore Igbe
- Center for Diabetes Technology, School of Medicine, University of Virginia, VA22903, USA
| | - Asha Kumari
- Department of Chemistry, Career Point University, Himachal Pradesh, 176041, India
| | - Rahul Sharma
- Department of Chemistry, Career Point University, Himachal Pradesh, 176041, India
| | - Suresh Kumar
- Department of Physics, MMU University, Ambala, Haryana, India
| | - Chongkol Sungoum
- Faculty of Engineering, Shinawatra University, Pathumthani, 12160, Thailand
| |
Collapse
|
2
|
Daley C, Doris M, Verner MA, Zalzal J, Chesnaux R, Minet L, Kang M, MacLean HL, Hatzopoulou M, Owens-Beek N, Caron-Beaudoin É. Residential proximity to conventional and unconventional wells and exposure to indoor air volatile organic compounds in the Exposures in the Peace River Valley (EXPERIVA) study. Int J Hyg Environ Health 2024; 263:114462. [PMID: 39293310 DOI: 10.1016/j.ijheh.2024.114462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 09/02/2024] [Accepted: 09/12/2024] [Indexed: 09/20/2024]
Abstract
BACKGROUND In a previous study located in Northeastern British Columbia (Canada), we observed associations between density and proximity of oil and gas wells and indoor air concentrations of certain volatile organic compounds (VOCs). Whether conventional or unconventional well types and phases of unconventional development contribute to these associations remains unknown. OBJECTIVE To investigate the associations between proximity-based metrics for conventional and unconventional wells and measured indoor air VOC concentrations in the Exposures in the Peace River Valley (EXPERIVA) study samples. METHODS Eighty-four pregnant individuals participated in EXPERIVA. Passive indoor air samplers were analyzed for 47 VOCs. Oil and gas well legacy data were sourced from the British Columbia Energy Regulator. For each participant's home, 5 km, 10 km and no buffer distances were delineated, then density and Inverse Distance Square Weighted (ID2W) metrics were calculated to estimate exposure to conventional and unconventional wells during pregnancy and the VOC measurement period. Multiple linear regression models were used to test for associations between the well exposure metrics and indoor air VOCs. For exposure metrics with >30% participants having a value of 0, we dichotomized exposure (0 vs. >0) and performed ANOVAs to assess differences in mean VOCs concentrations. RESULTS Analyses indicated that: 1) conventional well density and ID2W metrics were positively associated with indoor air acetone and decanal; 2) unconventional well density and ID2W metrics were positively associated with indoor air chloroform and decamethylcyclopentasiloxane, and negatively associated with decanal; 3) drilling specific ID2W metrics for unconventional wells were positively associated with indoor air chloroform. CONCLUSION Our analysis revealed that the association between the exposure metrics and indoor air acetone could be attributed to conventional wells and the association between exposure metrics and indoor air chloroform and decamethylcyclopentasiloxane could be attributed to unconventional wells.
Collapse
Affiliation(s)
- Coreen Daley
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto, Ontario, Canada
| | - Miranda Doris
- Civil and Mineral Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Marc-André Verner
- Centre de Recherche en Santé Publique, Université de Montréal et CIUSSS du Centre-Sud-de-l'Île-de-Montréal, Montreal, Quebec, Canada; Department of Occupational and Environmental Health, School of Public Health, Université de Montréal, Montreal, Quebec, Canada
| | - Jad Zalzal
- Civil and Mineral Engineering, University of Toronto, Toronto, Ontario, Canada
| | - Romain Chesnaux
- Applied Sciences, University of Quebec at Chicoutimi, Quebec, Canada
| | - Laura Minet
- Civil Engineering, University of Victoria, British Columbia, Canada
| | - Mary Kang
- Civil Engineering, McGill University, Quebec, Canada
| | - Heather L MacLean
- Civil and Mineral Engineering, University of Toronto, Toronto, Ontario, Canada
| | | | | | - Élyse Caron-Beaudoin
- Department of Physical and Environmental Sciences, University of Toronto Scarborough, Toronto, Ontario, Canada; Department of Health and Society, University of Toronto Scarborough, Toronto, Ontario, Canada; Dalla Lana School of Public Health, University of Toronto, Toronto, Ontario, Canada; Centre for Clinical Epidemiology and Evaluation, University of British Columbia, Vancouver, British Columbia, Canada.
| |
Collapse
|
3
|
Khan AU, Tahir M, Nisa FU, Naseem M, Shahbaz I, Ma Z, Hu Z, Khan AJ, Sabir M, He L. Non-Invasive Multi-Gas Detection Enabled by Cu-CuO/PEDOT Microneedle Sensor. SENSORS (BASEL, SWITZERLAND) 2024; 24:3623. [PMID: 38894418 PMCID: PMC11175360 DOI: 10.3390/s24113623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 05/25/2024] [Accepted: 05/31/2024] [Indexed: 06/21/2024]
Abstract
Metal-oxide-based gas sensors are extensively utilized across various domains due to their cost-effectiveness, facile fabrication, and compatibility with microelectronic technologies. The copper (Cu)-based multifunctional polymer-enhanced sensor (CuMPES) represents a notably tailored design for non-invasive environmental monitoring, particularly for detecting diverse gases with a low concentration. In this investigation, the Cu-CuO/PEDOT nanocomposite was synthesized via a straightforward chemical oxidation and vapor-phase polymerization. Comprehensive characterizations employing X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), X-ray diffraction (XRD), and micro Raman elucidated the composition, morphology, and crystal structure of this nanocomposite. Gas-sensing assessments of this CuMPES based on Cu-CuO/PEDOT revealed that the response current of the microneedle-type CuMPES surpassed that of the pure Cu microsensor by nearly threefold. The electrical conductivity and surface reactivity are enhanced by poly (3,4-ethylenedioxythiophene) (PEDOT) polymerized on the CuO-coated surface, resulting in an enhanced sensor performance with an ultra-fast response/recovery of 0.3/0.5 s.
Collapse
Affiliation(s)
- Arif Ullah Khan
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
| | - Muhammad Tahir
- School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Fazal Ul Nisa
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
| | - Mizna Naseem
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
| | - Iqra Shahbaz
- Key Laboratory of Green Printing, CAS Research/Education Centre for Excellence in Molecular Sciences, Institute of Chemistry Chinese Academy of Sciences (ICCAS), Beijing 100190, China;
| | - Zeyu Ma
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
| | - Zilu Hu
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
| | - Abdul Jabbar Khan
- College of Chemistry and Chemical Engineering, Huanggang Normal University, Huanggang 438000, China
| | - Muhammad Sabir
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing, Wuhan University of Technology, Wuhan 430070, China;
| | - Liang He
- State Key Laboratory of Intelligent Construction and Healthy Operation and Maintenance of Deep Underground Engineering, School of Mechanical Engineering, Sichuan University, Chengdu 610065, China; (A.U.K.); (F.U.N.); (M.N.); (Z.M.); (Z.H.)
- Med+X Center for Manufacturing, West China Hospital, Sichuan University, Chengdu 610041, China
- Yibin Industrial Technology Research Institute, Yibin R&D Park, Sichuan University, Yibin 644005, China
| |
Collapse
|
4
|
Zhao Z, Lv Z, Chen Z, Zhou B, Shao Z. α-Fe 2O 3/TiO 2/Ti 3C 2T x Nanocomposites for Enhanced Acetone Gas Sensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:2604. [PMID: 38676221 PMCID: PMC11054869 DOI: 10.3390/s24082604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 04/06/2024] [Accepted: 04/11/2024] [Indexed: 04/28/2024]
Abstract
Metal oxide semi-conductors are widely applied in various fields due to their low cost, easy processing, and good compatibility with microelectronic technology. In this study, ternary α-Fe2O3/TiO2/Ti3C2Tx nanocomposites were prepared via simple hydrothermal and annealing treatments. The composition, morphology, and crystal structure of the samples were studied using XPS, SEM, EDS, XRD, and multiple other testing methods. The gas-sensing measurement results suggest that the response value (34.66) of the F/M-3 sensor is 3.5 times higher than the pure α-Fe2O3 sensor (9.78) around 100 ppm acetone at 220°C, with a rapid response and recovery time (10/7 s). Furthermore, the sensors have an ultra-low detection limit (0.1 ppm acetone), excellent selectivity, and long-term stability. The improved sensitivity of the composites is mainly attributed to their excellent metal conductivity, the unique two-dimensional layered structure of Ti3C2Tx, and the heterojunction formed between the nanocomposite materials. This research paves a new route for the preparation of MXene derivatives and metal oxide nanocomposites.
Collapse
Affiliation(s)
- Zhihua Zhao
- College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China; (Z.L.); (Z.C.); (B.Z.)
| | - Zhenli Lv
- College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China; (Z.L.); (Z.C.); (B.Z.)
| | - Zhuo Chen
- College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China; (Z.L.); (Z.C.); (B.Z.)
| | - Baocang Zhou
- College of Mechanical and Electrical Engineering, Henan University of Technology, Zhengzhou 450052, China; (Z.L.); (Z.C.); (B.Z.)
| | - Zhigang Shao
- Laboratory of Coordination Chemistry, CNRS UPR 8241, University of Toulouse, 205 Route de Narbonne, 31077 Toulouse, France
| |
Collapse
|
5
|
Xing Q, Zhang L, Liu H, Zhu C, Yao M. Exhaled VOC Biomarkers from Rats Injected with PMs from Thirty-One Major Cities in China. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:20510-20520. [PMID: 38039547 DOI: 10.1021/acs.est.3c06074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2023]
Abstract
Particulate matter (PMs) of different origins can cause diverse health effects. Here, a homemade box was used to facilitate real-time measurements of breath-borne volatile organic compounds (VOCs) by gas chromatography-ion mobility spectrometry. We have tracked exhaled VOC changes in 228 Wistar rats that were injected with water-soluble PM suspension filtrates (after 0.45 μm) from 31 China cities for 1 h to up to 1-6 days during the experiments. Rats exposed to the filtrates exhibited significant changes in breath-borne VOCs within hours, featuring dynamic fluctuations in the levels of acetone, butan-2-one, heptan-2-one-M, acetic acid-M, and ethanol. Subsequently, on the fifth to sixth day after the injection, there was a notable increase in the proportion of aldehydes (including hexanal-M, hexanal-D, pentanal, heptanal-M, and (E)-2-hexenal). The 10 dynamic VOC fingerprint patterns mentioned earlier showcased the capability to indirectly differentiate urban PM toxicity and categorize the 31 cities into four distinct groups based on their health effects. This study provides valuable insights into the mechanisms of exhaled VOCs and underscores their critical role as biomarkers for differentiating the toxicity of different PMs and detecting the early signs of potential diseases. The results from this work also provide a scientific basis for city-specific air pollution control and policy development.
Collapse
Affiliation(s)
- Qisong Xing
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Lu Zhang
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Huaying Liu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Chenyu Zhu
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| | - Maosheng Yao
- State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, Beijing 100871, China
| |
Collapse
|
6
|
Xu W, Zou X, Ding H, Ding Y, Zhang J, Liu W, Gong T, Nie Z, Yang M, Zhou Q, Liu Z, Ge D, Zhang Q, Huang C, Shen C, Chu Y. Rapid and non-invasive diagnosis of type 2 diabetes through sniffing urinary acetone by a proton transfer reaction mass spectrometry. Talanta 2023; 256:124265. [PMID: 36669369 DOI: 10.1016/j.talanta.2023.124265] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 01/06/2023] [Accepted: 01/09/2023] [Indexed: 01/12/2023]
Abstract
Urinary acetone in urine is produced from fat metabolism in human body, which can be accelerated in diabetic patients because of insufficient utilization and storage of glucose. In this study, we tried to develop a novel diagnosis method of type 2 diabetes (T2D) through sniffing urinary acetone by a proton transfer reaction mass spectrometry (PTR-MS). A total of 180 T2D patients and 180 healthy volunteers were recruited from three hospitals for multicenter study. Urine samples were collected in the morning when donators were fasting and stored in glass bottles. Acetone in the headspace of these bottles was qualitatively and quantitatively detected by the PTR-MS in 8 h. Using a threshold of 690.1 ppbv, a diagnostic model was established using urinary acetone with an accuracy of 81.3% (sensitivity: 73.3%, specificity: 89.3%) in hospital Ⅰ. In the verification studies, the accuracies were 92.5% (sensitivity: 88.7%, specificity: 96.2%) in hospital Ⅱ and 83.7% (sensitivity: 76.9%, specificity: 90.4%) in hospital Ⅲ, respectively. The accuracy is comparable to that of clinically used diagnosis methods, fasting plasma glucose (FPG), oral glucose tolerance test (OGTT), and glycosylated hemoglobin A1c (HbA1c) test. The sensitivity for 35 newly diagnosed patients was 85.7%. The newly developed technology is completely non-invasive and much more rapid than clinical FPG, OGTT, and HbA1c tests. It has a promising prospect in clinical use. But the applicability in different human races still need more validations.
Collapse
Affiliation(s)
- Wei Xu
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China; University of Science and Technology of China, 230026, Hefei, China
| | - Xue Zou
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China.
| | - Houwen Ding
- The Second Hospital of Anhui Medical University, 230601, Hefei, China
| | - Yueting Ding
- The Second Hospital of Anhui Medical University, 230601, Hefei, China
| | - Jin Zhang
- The Second Hospital of Anhui Medical University, 230601, Hefei, China
| | - Wenting Liu
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China; University of Science and Technology of China, 230026, Hefei, China
| | - Tingting Gong
- The First Affiliated Hospital of Anhui Medical University, 230088, Hefei, China
| | - Zhengchao Nie
- Anhui Provincial Hospital/The First Affiliated Hospital of USTC, 230001, Hefei, China
| | - Min Yang
- The Second Hospital of Anhui Medical University, 230601, Hefei, China.
| | - Qiang Zhou
- The Second Hospital of Anhui Medical University, 230601, Hefei, China
| | - Zhou Liu
- The Second Hospital of Anhui Medical University, 230601, Hefei, China
| | - Dianlong Ge
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China
| | - Qiangling Zhang
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China
| | - Chaoqun Huang
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China
| | - Chengyin Shen
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China; Hefei Cancer Hospital, Chinese Academy of Sciences, 230031, Hefei, China.
| | - Yannan Chu
- Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, 230031, Hefei, China
| |
Collapse
|
7
|
Abbas A, Mansoor S, Nawaz MH, Chaudhry AA, Ijaz K, Riaz S, Hayat A. Growth of diazonium-functionalized ZnO nanoflakes on flexible carbon cloth for electrochemical sensing of acetone in the liquid phase. RSC Adv 2023; 13:11537-11545. [PMID: 37063710 PMCID: PMC10098440 DOI: 10.1039/d3ra01268a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Accepted: 03/27/2023] [Indexed: 04/18/2023] Open
Abstract
Simple detection of acetone is indispensable due to its health and environmental concerns. Surface-modified electrodes are promising for the detection of acetone. In the present study, the facile fabrication of ZnO nanoflakes on carbon cloth (CC) is reported. The electrode was fabricated by decorating the CC with ZnO nanoparticles (ZnO NPs), followed by the hydrothermal treatment and modification with diazonium salt using linear sweep voltammetry (LSV) forming ZnO nanoflakes (ZnO NFs) on ZnO NPs/CC. The as-prepared ZnO/CC electrode was used for the detection of acetone at room temperature using cyclic voltammetry. Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM), scanning electron microscopy (SEM), X-ray diffraction (XRD), and Brunauer-Emmett-Teller (BET) analyses were used for the chemical and physical characterization of the CC before and after each modification step. The obtained data manifested that ZnO NFs functionalized with diazonium salt increased the roughness of the CC surface, which was advantageous to promote the interaction between CC and acetone target. The modified sensing platform showed excellent performance in terms of the wide working range (0.1-2000 ppm) and low detection limit (0.03 ppm), making it a promising and cost-effective sensor of acetone in the liquid phase.
Collapse
Affiliation(s)
- Azhar Abbas
- Institute of Chemistry, University of Sargodha Sargodha 40100 Pakistan
| | - Seemal Mansoor
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| | - Mian Hasnain Nawaz
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| | - Aqif Anwar Chaudhry
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| | - Kashif Ijaz
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| | - Sara Riaz
- Department of Chemistry, COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| | - Akhtar Hayat
- Interdisciplinary Research Centre in Biomedical Materials (IRCBM), COMSATS University Islamabad Lahore Campus Lahore 54000 Pakistan
| |
Collapse
|
8
|
Pangerl J, Moser E, Müller M, Weigl S, Jobst S, Rück T, Bierl R, Matysik FM. A sub-ppbv-level Acetone and Ethanol Quantum Cascade Laser Based Photoacoustic Sensor - Characterization and Multi-Component Spectra Recording in Synthetic Breath. PHOTOACOUSTICS 2023; 30:100473. [PMID: 36970564 PMCID: PMC10033733 DOI: 10.1016/j.pacs.2023.100473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 02/24/2023] [Accepted: 03/09/2023] [Indexed: 06/18/2023]
Abstract
Trace gas analysis in breath is challenging due to the vast number of different components. We present a highly sensitive quantum cascade laser based photoacoustic setup for breath analysis. Scanning the range between 8263 and 8270 nm with a spectral resolution of 48 pm, we are able to quantify acetone and ethanol within a typical breath matrix containing water and CO2. We photoacoustically acquired spectra within this region of mid-infra-red light and prove that those spectra do not suffer from non-spectral interferences. The purely additive behavior of a breath sample spectrum was verified by comparing it with the independently acquired single component spectra using Pearson and Spearman correlation coefficients. A previously presented simulation approach is improved and an error attribution study is presented. With a 3σ detection limit of 6.5 ppbv in terms of ethanol and 250 pptv regarding acetone, our system is among the best performing presented so far.
Collapse
Affiliation(s)
- Jonas Pangerl
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
- Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Elisabeth Moser
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
- Faculty of Informatics, Technical University of Munich, 85748 Garching, Germany
| | - Max Müller
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
- Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Stefan Weigl
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
| | - Simon Jobst
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
- Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Thomas Rück
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
| | - Rudolf Bierl
- Sensorik-ApplikationsZentrum (SappZ), Regensburg University of Applied Sciences, 93053 Regensburg, Germany
| | - Frank-Michael Matysik
- Institute of Analytical Chemistry, Chemo, and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
9
|
Zhao Y, Dong B, Benkstein KD, Chen L, Steffens KL, Semancik S. Deep Learning Image Analysis of Nanoplasmonic Sensors: Toward Medical Breath Monitoring. ACS APPLIED MATERIALS & INTERFACES 2022; 14:54411-54422. [PMID: 36418023 DOI: 10.1021/acsami.2c11153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Sensing biomarkers in exhaled breath offers a potentially portable, cost-effective, and noninvasive strategy for disease diagnosis screening and monitoring, while high sensitivity, wide sensing range, and target specificity are critical challenges. We demonstrate a deep learning-assisted plasmonic sensing platform that can detect and quantify gas-phase biomarkers in breath-related backgrounds of varying complexity. The sensing interface consisted of Au/SiO2 nanopillars covered with a 15 nm metal-organic framework. A small camera was utilized to capture the plasmonic sensing responses as images, which were subjected to deep learning signal processing. The approach has been demonstrated at a classification accuracy of 95 to 98% for the diabetic ketosis marker acetone within a concentration range of 0.5-80 μmol/mol. The reported work provides a thorough exploration of single-sensor capabilities and sets the basis for more advanced utilization of artificial intelligence in sensing applications.
Collapse
Affiliation(s)
- Yangyang Zhao
- Biomolecular Measurement Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland20899, United States
- Sensing Labs, Inc., Rockville, Maryland20850, United States
| | - Boqun Dong
- Sensing Labs, Inc., Rockville, Maryland20850, United States
| | - Kurt D Benkstein
- Biomolecular Measurement Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland20899, United States
| | - Lei Chen
- Center for Nanoscale Science and Technology, Physical Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland20899, United States
| | - Kristen L Steffens
- Biomolecular Measurement Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland20899, United States
| | - Steve Semancik
- Biomolecular Measurement Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, Maryland20899, United States
| |
Collapse
|
10
|
Getahun MN, Ngiela J, Makwatta JO, Ahuya P, Simon TK, Kamau SK, Torto B, Masiga D. Metabolites From Trypanosome-Infected Cattle as Sensitive Biomarkers for Animal Trypanosomosis. Front Microbiol 2022; 13:922760. [PMID: 35910617 PMCID: PMC9329068 DOI: 10.3389/fmicb.2022.922760] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Accepted: 06/16/2022] [Indexed: 11/13/2022] Open
Abstract
Trypanosomes are important global livestock and human pathogens of public health importance. Elucidating the chemical mechanisms of trypanosome-relevant host interactions can enhance the design and development of a novel, next-generation trypanosomosis diagnostics. However, it is unknown how trypanosome infection affects livestock volatile odors. Here, we show that Trypanosoma congolense and Trypanosoma vivax infections induced dihydro-β- ionone and junenol, while abundance of dihydro-α-ionone, phenolics, p-cresol, and 3-propylphenol significantly elevated in cow urine. These biomarkers of trypanosome infection are conserved in cow breath and the urine metabolites of naturally infected cows, regardless of population, diet, or environment differences. Furthermore, treating trypanosome-infected cows reduced the levels of these indicators back to the pre-infection levels. Finally, we demonstrated that the potential of some specific biomarkers of phenolic origin may be used to detect active trypanosome infections, including low-level infections that are not detectable by microscopy. The sensitivity and specificity of biomarkers detection are suited for rapid, robust, and non-invasive trypanosomosis diagnosis under field conditions.
Collapse
Affiliation(s)
- Merid N. Getahun
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
- *Correspondence: Merid N. Getahun,
| | - John Ngiela
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
| | | | - Peter Ahuya
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
| | - Tawich K. Simon
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
| | | | - Baldwyn Torto
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
| | - Daniel Masiga
- International Centre of Insect Physiology and Ecology, Nairobi, Kenya
| |
Collapse
|
11
|
Cataluminescence sensor based on Pt/NU-901 nanocomposite for rapid capture, catalysis and detection of acetone in exhaled breath. Anal Chim Acta 2022; 1206:339787. [DOI: 10.1016/j.aca.2022.339787] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/27/2022] [Accepted: 03/28/2022] [Indexed: 02/07/2023]
|
12
|
Deep Learning for Type 1 Diabetes Mellitus Diagnosis Using Infrared Quantum Cascade Laser Spectroscopy. MATERIALS 2022; 15:ma15092984. [PMID: 35591319 PMCID: PMC9099836 DOI: 10.3390/ma15092984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 04/12/2022] [Accepted: 04/17/2022] [Indexed: 12/05/2022]
Abstract
An estimated 10.5% of the world’s population aged 20–79 years are currently living with diabetes in 2021. An urgent task is to develop a non-invasive express-diagnostics of diabetes with high accuracy. Type 1 diabetes mellitus (T1DM) diagnostic method based on infrared laser spectroscopy of human exhaled breath is described. A quantum cascade laser emitting in a pulsed mode with a peak power of up to 150 mW in the spectral range of 5.3–12.8 μm and Herriot multipass gas cell with an optical path length of 76 m were used. We propose a method for collecting and drying an exhaled human air sample and have measured 1200 infrared exhaled breath spectra from 60 healthy volunteers (the control group) and 60 volunteers with confirmed T1DM (the target group). A 1-D convolutional neural network for the classification of healthy and T1DM volunteers with an accuracy of 99.7%, recall 99.6% and AUC score 99.9% was used. The demonstrated results require clarification on a larger dataset and series of clinical studies and, further, the method can be implemented in routine medical practice.
Collapse
|
13
|
Sha M, Maurya MR, Shafath S, Cabibihan JJ, Al-Ali A, Malik RA, Sadasivuni KK. Breath Analysis for the In Vivo Detection of Diabetic Ketoacidosis. ACS OMEGA 2022; 7:4257-4266. [PMID: 35155918 PMCID: PMC8830064 DOI: 10.1021/acsomega.1c05948] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Accepted: 01/10/2022] [Indexed: 06/14/2023]
Abstract
Human breath analysis of volatile organic compounds has gained significant attention recently because of its rapid and noninvasive potential to detect various metabolic diseases. The detection of ketones in the breath and blood is key to diagnosing and managing diabetic ketoacidosis (DKA) in patients with type 1 diabetes. It may also be of increasing importance to detect euglycemic ketoacidosis in patients with type 1 or type 2 diabetes or heart failure, treated with sodium-glucose transporter-2 inhibitors (SGLT2-i). The present research evaluates the efficiency of colorimetry for detecting acetone and ethanol in exhaled human breath with the response time, pH effect, temperature effect, concentration effect, and selectivity of dyes. Using the proposed multidye system, we obtained a detection limit of 0.0217 ppm for acetone and 0.029 ppm for ethanol in the detection range of 0.05-50 ppm. A smartphone-assisted unit consisting of a portable colorimetric device was used to detect relative red/green/blue values within 60 s of the interface for practical and real-time application. The developed method could be used for rapid, low-cost detection of ketones in patients with type 1 diabetes and DKA and patients with type 1 or type 2 diabetes or heart failure treated with SGLT2-I and euglycemic ketoacidosis.
Collapse
Affiliation(s)
- Mizaj
Shabil Sha
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Muni Raj Maurya
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
- Department
of Mechanical and Industrial Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Sadiyah Shafath
- Center
for Advanced Materials, Qatar University, P.O. Box 2713, Doha 2713, Qatar
- Department
of Chemical Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - John-John Cabibihan
- Department
of Mechanical and Industrial Engineering, Qatar University, P.O. Box 2713, Doha 2713, Qatar
| | - Abdulaziz Al-Ali
- Department
of Computer Science and Engineering, Qatar
University, P.O. Box 2713, Doha 2713, Qatar
- KINDI
Center for Computing Research, Qatar University, Doha 2713, Qatar
| | - Rayaz A. Malik
- Weill Cornell
Medicine-Qatar, Qatar Foundation-Education
City, P.O. Box 24144, Doha 2713, Qatar
| | | |
Collapse
|
14
|
Issitt T, Wiggins L, Veysey M, Sweeney S, Brackenbury W, Redeker K. Volatile compounds in human breath: critical review and meta-analysis. J Breath Res 2022; 16. [PMID: 35120340 DOI: 10.1088/1752-7163/ac5230] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 02/04/2022] [Indexed: 11/12/2022]
Abstract
Volatile compounds contained in human breath reflect the inner workings of the body. A large number of studies have been published that link individual components of breath to disease, but diagnostic applications remain limited, in part due to inconsistent and conflicting identification of breath biomarkers. New approaches are therefore required to identify effective biomarker targets. Here, volatile organic compounds have been identified in the literature from four metabolically and physiologically distinct diseases and grouped into chemical functional groups (e.g. - methylated hydrocarbons or aldehydes; based on known metabolic and enzymatic pathways) to support biomarker discovery and provide new insight on existing data. Using this functional grouping approach, principal component analysis doubled explanatory capacity from 19.1% to 38% relative to single individual compound approaches. Random forest and linear discriminant analysis reveal 93% classification accuracy for cancer. This review and meta-analysis provides insight for future research design by identifying volatile functional groups associated with disease. By incorporating our understanding of the complexities of the human body, along with accounting for variability in methodological and analytical approaches, this work demonstrates that a suite of targeted, functional volatile biomarkers, rather than individual biomarker compounds, will improve accuracy and success in diagnostic research and application.
Collapse
Affiliation(s)
- Theo Issitt
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Laura Wiggins
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Martin Veysey
- The University of Newcastle, School of Medicine & Public Health, Callaghan, New South Wales, 2308, AUSTRALIA
| | - Sean Sweeney
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - William Brackenbury
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Kelly Redeker
- Biology, University of York, Biology Dept. University of York, York, York, North Yorkshire, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
15
|
Hu W, Wu W, Jian Y, Haick H, Zhang G, Qian Y, Yuan M, Yao M. Volatolomics in healthcare and its advanced detection technology. NANO RESEARCH 2022; 15:8185-8213. [PMID: 35789633 PMCID: PMC9243817 DOI: 10.1007/s12274-022-4459-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 04/18/2022] [Accepted: 04/20/2022] [Indexed: 05/21/2023]
Abstract
Various diseases increasingly challenge the health status and life quality of human beings. Volatolome emitted from patients has been considered as a potential family of markers, volatolomics, for diagnosis/screening. There are two fundamental issues of volatolomics in healthcare. On one hand, the solid relationship between the volatolome and specific diseases needs to be clarified and verified. On the other hand, effective methods should be explored for the precise detection of volatolome. Several comprehensive review articles had been published in this field. However, a timely and systematical summary and elaboration is still desired. In this review article, the research methodology of volatolomics in healthcare is critically considered and given out, at first. Then, the sets of volatolome according to specific diseases through different body sources and the analytical instruments for their identifications are systematically summarized. Thirdly, the advanced electronic nose and photonic nose technologies for volatile organic compounds (VOCs) detection are well introduced. The existed obstacles and future perspectives are deeply thought and discussed. This article could give a good guidance to researchers in this interdisciplinary field, not only understanding the cutting-edge detection technologies for doctors (medicinal background), but also making reference to clarify the choice of aimed VOCs during the sensor research for chemists, materials scientists, electronics engineers, etc.
Collapse
Affiliation(s)
- Wenwen Hu
- School of Aerospace Science and Technology, Xidian University, Xi’an, 730107 China
| | - Weiwei Wu
- Interdisciplinary Research Center of Smart Sensors, School of Advanced Materials and Nanotechnology, Xidian University, Xi’an, 730107 China
| | - Yingying Jian
- Interdisciplinary Research Center of Smart Sensors, School of Advanced Materials and Nanotechnology, Xidian University, Xi’an, 730107 China
| | - Hossam Haick
- Faculty of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, 3200002 Israel
| | - Guangjian Zhang
- Department of Thoracic Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, 710061 China
| | - Yun Qian
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, 310006 China
| | - Miaomiao Yuan
- The Eighth Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518033 China
| | - Mingshui Yao
- State Key Laboratory of Multi-phase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 310006 China
- Institute for Integrated Cell-Material Sciences, Kyoto University Institute for Advanced Study, Kyoto University, Kyoto, 606-8501 Japan
| |
Collapse
|
16
|
Functional Microfiber Nonwoven Fabric with Copper Ion-Immobilized Polymer Brush for Detection and Adsorption of Acetone Gas. SENSORS 2021; 22:s22010091. [PMID: 35009635 PMCID: PMC8747101 DOI: 10.3390/s22010091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 12/15/2021] [Accepted: 12/15/2021] [Indexed: 01/06/2023]
Abstract
The detection and removal of volatile organic compounds (VOCs) are emerging as an important problem in modern society. In this study, we attempted to develop a new material capable of detecting or adsorbing VOCs by introducing a new functional group and immobilizing metal ions into a microfiber nonwoven fabric (MNWF) made through radiation-induced graft polymerization. The suitable metal complex was selected according to the data in “Cambridge Crystallographic Data Center (CCDC)”. 4-picolylamine (4-AMP), designated as a ligand through the metal complex data of CCDC, was introduced at an average mole conversion rate of 63%, and copper ions were immobilized at 0.51 mmol/g to the maximum. It was confirmed that degree of grafting (dg) 170% 4-AMP-Cu MNWF, where copper ions are immobilized, can adsorb up to 50% of acetone gas at about 50 ppm, 0.04 mmol/g- 4-AMP-Cu-MNWF, at room temperature and at a ratio of copper ion to adsorbed acetone of 1:10.
Collapse
|
17
|
Metabolomics profiling of human exhaled breath condensate by SPME/GC × GC-ToFMS: Exploratory study on the use of face masks at the level of lipid peroxidation volatile markers. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106830] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
18
|
Dixit K, Fardindoost S, Ravishankara A, Tasnim N, Hoorfar M. Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities. BIOSENSORS 2021; 11:476. [PMID: 34940233 PMCID: PMC8699302 DOI: 10.3390/bios11120476] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/18/2021] [Accepted: 11/20/2021] [Indexed: 05/15/2023]
Abstract
With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.
Collapse
Affiliation(s)
- Kaushiki Dixit
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India;
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Somayeh Fardindoost
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Adithya Ravishankara
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Nishat Tasnim
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| |
Collapse
|
19
|
Zhou T, Dong W, Qiu Y, Chen S, Wang X, Xie C, Zeng D. Selectivity of a ZnO@ZIF-71@PDMS Nanorod Array Gas Sensor Enhanced by Coating a Polymer Selective Separation Membrane. ACS APPLIED MATERIALS & INTERFACES 2021; 13:54589-54596. [PMID: 34747600 DOI: 10.1021/acsami.1c16637] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
It is important for noninvasive diagnosis of diabetes to develop acetone gas sensors with high selectivity. ZnO@ZIF-71 has been reported as a highly sensitive and selective gas sensor on acetone detection. However, it is difficult to exclude the interference with similar molecular sizes gas in the gas-sensing process, like ethanol. To solve this problem, polydimethylsiloxane (PDMS) was synthesized on the surface of ZnO@ZIF-71 to form a ZnO@ZIF-71@PDMS sensor by vapor deposition. The new sensor shows inert response to ethanol and effective response to acetone simultaneously. The PDMS membrane acts as a molecular sieve, which shows the acetone selectivity performance and can totally eliminate the response to low concentration ethanol at low temperature. Theory calculations and solubility test are also employed to prove the role PDMS plays in this process. It demonstrated that the acetone selectivity performance comes from the hydrogen bond interaction between the ethanol gas molecules and PDMS, which increases difficulty for ethanol gas molecules to penetrate the PDMS membrane. Further, this work provides a new method for enhancing gas-sensing selectivity and promoting for miniaturization of gas sensors.
Collapse
Affiliation(s)
- Tingting Zhou
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Wenbo Dong
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Yue Qiu
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Shiyu Chen
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Xiaoxia Wang
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Changsheng Xie
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| | - Dawen Zeng
- State Key Laboratory of Material Processing and Die & Mould Technology, Department of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, People's Republic of China
| |
Collapse
|
20
|
Diouri O, Cigler M, Vettoretti M, Mader JK, Choudhary P, Renard E. Hypoglycaemia detection and prediction techniques: A systematic review on the latest developments. Diabetes Metab Res Rev 2021; 37:e3449. [PMID: 33763974 PMCID: PMC8519027 DOI: 10.1002/dmrr.3449] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 12/08/2020] [Accepted: 01/28/2021] [Indexed: 02/06/2023]
Abstract
The main objective of diabetes control is to correct hyperglycaemia while avoiding hypoglycaemia, especially in insulin-treated patients. Fear of hypoglycaemia is a hurdle to effective correction of hyperglycaemia because it promotes under-dosing of insulin. Strategies to minimise hypoglycaemia include education and training for improved hypoglycaemia awareness and the development of technologies to allow their early detection and thus minimise their occurrence. Patients with impaired hypoglycaemia awareness would benefit the most from these technologies. The purpose of this systematic review is to review currently available or in-development technologies that support detection of hypoglycaemia or hypoglycaemia risk, and identify gaps in the research. Nanomaterial use in sensors is a promising strategy to increase the accuracy of continuous glucose monitoring devices for low glucose values. Hypoglycaemia is associated with changes on vital signs, so electrocardiogram and encephalogram could also be used to detect hypoglycaemia. Accuracy improvements through multivariable measures can make already marketed galvanic skin response devices a good noninvasive alternative. Breath volatile organic compounds can be detected by dogs and devices and alert patients at hypoglycaemia onset, while near-infrared spectroscopy can also be used as a hypoglycaemia alarms. Finally, one of the main directions of research are deep learning algorithms to analyse continuous glucose monitoring data and provide earlier and more accurate prediction of hypoglycaemia. Current developments for early identification of hypoglycaemia risk combine improvements of available 'needle-type' enzymatic glucose sensors and noninvasive alternatives. Patient usability will be essential to demonstrate to allow their implementation for daily use in diabetes management.
Collapse
Affiliation(s)
- Omar Diouri
- Department of Endocrinology, Diabetes, NutritionMontpellier University HospitalMontpellierFrance
- Department of PhysiologyInstitute of Functional Genomics, CNRS, INSERMUniversity of MontpellierMontpellierFrance
| | - Monika Cigler
- Division of Endocrinology and DiabetologyDepartment of Internal MedicineMedical University of GrazGrazAustria
| | | | - Julia K. Mader
- Division of Endocrinology and DiabetologyDepartment of Internal MedicineMedical University of GrazGrazAustria
| | - Pratik Choudhary
- Department of Diabetes and Nutritional SciencesKing's College LondonLondonUK
- Diabetes Research CentreUniversity of LeicesterLeicesterUK
| | - Eric Renard
- Department of Endocrinology, Diabetes, NutritionMontpellier University HospitalMontpellierFrance
- Department of PhysiologyInstitute of Functional Genomics, CNRS, INSERMUniversity of MontpellierMontpellierFrance
| | | |
Collapse
|
21
|
Kim C, Raja IS, Lee JM, Lee JH, Kang MS, Lee SH, Oh JW, Han DW. Recent Trends in Exhaled Breath Diagnosis Using an Artificial Olfactory System. BIOSENSORS 2021; 11:337. [PMID: 34562928 PMCID: PMC8467588 DOI: 10.3390/bios11090337] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/06/2021] [Accepted: 09/10/2021] [Indexed: 12/26/2022]
Abstract
Artificial olfactory systems are needed in various fields that require real-time monitoring, such as healthcare. This review introduces cases of detection of specific volatile organic compounds (VOCs) in a patient's exhaled breath and discusses trends in disease diagnosis technology development using artificial olfactory technology that analyzes exhaled human breath. We briefly introduce algorithms that classify patterns of odors (VOC profiles) and describe artificial olfactory systems based on nanosensors. On the basis of recently published research results, we describe the development trend of artificial olfactory systems based on the pattern-recognition gas sensor array technology and the prospects of application of this technology to disease diagnostic devices. Medical technologies that enable early monitoring of health conditions and early diagnosis of diseases are crucial in modern healthcare. By regularly monitoring health status, diseases can be prevented or treated at an early stage, thus increasing the human survival rate and reducing the overall treatment costs. This review introduces several promising technical fields with the aim of developing technologies that can monitor health conditions and diagnose diseases early by analyzing exhaled human breath in real time.
Collapse
Affiliation(s)
- Chuntae Kim
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
| | | | - Jong-Min Lee
- School of Nano Convergence Technology, Hallym University, Chuncheon 24252, Korea
| | | | - Moon Sung Kang
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Seok Hyun Lee
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Jin-Woo Oh
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Nanoenergy Engineering, Pusan National University, Busan 46241, Korea
| | - Dong-Wook Han
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| |
Collapse
|
22
|
Hüppe T, Lorenz D, Maurer F, Fink T, Klumpp R, Kreuer S. Quantification of Volatile Acetone Oligomers Using Ion-Mobility Spectrometry. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2021; 2021:6638036. [PMID: 34395017 PMCID: PMC8355975 DOI: 10.1155/2021/6638036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 07/27/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND Volatile acetone is a potential biomarker that is elevated in various disease states. Measuring acetone in exhaled breath is complicated by the fact that the molecule might be present as both monomers and dimers, but in inconsistent ratios. Ignoring the molecular form leads to incorrect measured concentrations. Our first goal was to evaluate the monomer-dimer ratio in ambient air, critically ill patients, and rats. Our second goal was to confirm the accuracy of the combined (monomer and dimer) analysis by comparison to a reference calibration system. METHODS Volatile acetone intensities from exhaled air of ten intubated, critically ill patients, and ten ventilated Sprague-Dawley rats were recorded using ion-mobility spectrometry. Acetone concentrations in ambient air in an intensive care unit and in a laboratory were determined over 24 hours. The calibration reference was pure acetone vaporized by a gas generator at concentrations from 5 to 45 ppbv (parts per billion by volume). RESULTS Acetone concentrations in ambient laboratory air were only slightly greater (5.6 ppbv; 95% CI 5.1-6.2) than in ambient air in an intensive care unit (5.1 ppbv; 95% CI 4.4-5.5; p < 0.001). Exhaled acetone concentrations were only slightly greater in rats (10.3 ppbv; 95% CI 9.7-10.9) than in critically ill patients (9.5 ppbv; 95% CI 7.9-11.1; p < 0.001). Vaporization yielded acetone monomers (1.3-5.3 mV) and dimers (1.4-621 mV). Acetone concentrations (ppbv) and corresponding acetone monomer and dimer intensities (mV) revealed a high coefficient of determination (R 2 = 0.96). The calibration curve for acetone concentration (ppbv) and total acetone (monomers added to twice the dimers; mV) was described by the exponential growth 3-parameter model, with an R 2 = 0.98. CONCLUSION The ratio of acetone monomer and dimer is inconsistent and varies in ambient air from place-to-place and across individual humans and rats. Monomers and dimers must therefore be considered when quantifying acetone. Combining the two accurately assesses total volatile acetone.
Collapse
Affiliation(s)
- Tobias Hüppe
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| | - Dominik Lorenz
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| | - Felix Maurer
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| | - Tobias Fink
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| | - Ramona Klumpp
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| | - Sascha Kreuer
- Center of Breath Research, Department of Anaesthesiology, Intensive Care and Pain Therapy, Saarland University Medical Center, Homburg, Saarland 66424, Germany
| |
Collapse
|
23
|
Sudheer VR, SarathKumar SR, Sankararaman S. Nanostructured ZnO and ZnO: Pd with MXene overlayer SPR biosensors. OPTICAL AND QUANTUM ELECTRONICS 2021; 53:340. [PMID: 34188353 PMCID: PMC8224260 DOI: 10.1007/s11082-021-03042-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 06/08/2021] [Indexed: 06/13/2023]
Abstract
The development of biosensors based on various novel techniques has become highly significant in the context of the outburst of a pandemic like COVID 19. The present work reports the theoretical modeling of two surface plasmon resonance (SPR) based biosensing probe configurations on optical fiber employing Metal/ZnO/MXene and Metal/ZnO: Pd/MXene. Maximum sensitivities of 19,400 nm/RIU and 8350 nm/RIU are calculated with Metal/ZnO/MXene and Metal/ZnO: Pd/MXene, respectively. The sensors are suitable for analytes with refractive index values ranging from 1.354 to 1.422. The refractive index of mucus and serum being in this range, the proposed biosensor, can be a potential tool for COVID-19 detection.
Collapse
Affiliation(s)
- V. R. Sudheer
- Department of Optoelectronics, University of Kerala, Karyavattom, Thiruvananthapuram, 695581 India
- Department of Electronics and Communication, College of Engineering, Perumon, Kollam, 691601 India
| | - S. R. SarathKumar
- Department of Nanoscience and Nanotechnology, University of Kerala, Karyavattom, Thiruvananthapuram, 695581 India
| | - S. Sankararaman
- Department of Optoelectronics, University of Kerala, Karyavattom, Thiruvananthapuram, 695581 India
| |
Collapse
|
24
|
Vasudevan Pillai Radha S, Santhakumari
Amma Ravindran Nair SK, Sankaranarayana Iyer S. Surface Plasmon Resonance-Based Fiber-Optic Metallic Multilayer Biosensors. ACS OMEGA 2021; 6:15068-15077. [PMID: 34151087 PMCID: PMC8210446 DOI: 10.1021/acsomega.1c01236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Accepted: 05/18/2021] [Indexed: 05/25/2023]
Abstract
Accurate and quick sensing of various biomolecules relevant to different health conditions is indispensable in modern diagnosis and treatment procedures. Different multilayer metallic surface plasmon resonance (SPR) biosensor configurations comprising Au, Ag, Al, and Cu are analyzed in this work by employing an N-layer matrix formalism as applied to the fixed-angle spectral SPR sensing methodology. Stringent standards for sensitivity, detection accuracy, and figure of merit (FOM) of the sensor configurations are set to analyze the relative merits of one configuration over another. It is observed that three- and four-layer configurations using Al and Cu provide the best FOM among all sensors that passed the set standard criteria. The highest FOM (1433.82/RIU) is observed for the four-layer Al/Cu/Al/Cu sensor for an analyte refractive index of 1.408. The sensors are best suited for detecting analytes with a refractive index range of 1.350-1.414.
Collapse
|
25
|
Milyutin Y, Abud-Hawa M, Kloper-Weidenfeld V, Mansour E, Broza YY, Shani G, Haick H. Fabricating and printing chemiresistors based on monolayer-capped metal nanoparticles. Nat Protoc 2021; 16:2968-2990. [PMID: 34012107 DOI: 10.1038/s41596-021-00528-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 02/23/2021] [Indexed: 02/03/2023]
Abstract
Chemiresistors that are based on monolayer-capped metal nanoparticles (MCNPs) have been used in a wide variety of innovative sensing applications, including detection and monitoring of diagnostic markers in body fluids, explosive materials, environmental contaminations and food quality control. The sensing mechanism is based on reversible swelling or aggregation and/or changes in dielectric constant of the MCNPs. In this protocol, we describe a procedure for producing MCNP-based chemiresistive sensors that is reproducible from device to device and from batch to batch. The approach relies on three main steps: (i) controlled synthesis of gold MCNPs, (ii) fabrication of electrodes that are surrounded with a microbarrier ring to confine the deposited MCNP solution and (iii) a tailor-made drying process to enable evaporation of solvent residues from the MCNP sensing layer to prevent a coffee-ring effect. Application of this approach has been shown to produce devices with ±1.5% variance-a value consistent with the criterion for commercial sensors-as well as long shelf life and stability. Fabrication of chemical sensors based on dodecanethiol- or 2-ethylhexanethiol-capped MCNPs with this approach provides high sensitivity and accuracy in the detection of volatile organic compounds (e.g., octane and decane), toxic gaseous species (e.g., HCl and NH3) in air and simulated mixtures of lung and gastric cancer from exhaled breath.
Collapse
Affiliation(s)
- Yana Milyutin
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Manal Abud-Hawa
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Viki Kloper-Weidenfeld
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Elias Mansour
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Yoav Y Broza
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Gidi Shani
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel
| | - Hossam Haick
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, Israel.
| |
Collapse
|
26
|
Heeley-Hill AC, Grange SK, Ward MW, Lewis AC, Owen N, Jordan C, Hodgson G, Adamson G. Frequency of use of household products containing VOCs and indoor atmospheric concentrations in homes. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2021; 23:699-713. [PMID: 34037627 DOI: 10.1039/d0em00504e] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Volatile organic compounds (VOCs) are a key class of atmospheric emission released from highly complex petrochemical, transport and solvent sources both outdoors and indoors. This study established the concentrations and speciation of VOCs in 60 homes (204 individuals, 360 × 72 h samples, 40 species) in summer and winter, along with outdoor controls. Self-reported daily statistics were collected in each home on the use of cleaning, household and personal care products, all of which are known to release VOCs. Frequency of product use varied widely: deodorants: 2.9 uses home per day; sealant-mastics 0.02 uses home per day. The total concentration of VOCs indoors (range C2-C10) was highly variable between homes e.g. range 16.6-8150 μg m-3 in winter. Indoor concentrations of VOCs exceeded outdoor for 84% of households studied in summer and 100% of homes in winter. The most abundant VOCs found indoors in this study were n-butane (wintertime range: 1.5-4630 μg m-3), likely released as aerosol propellant, ethanol, acetone and propane. The cumulative use VOC-containing products over multiday timescales by occupants provided little predictive power to infer 72 hour averaged indoor concentrations. However, there was weak covariance between the cumulative usage of certain products and individual VOCs. From a domestic emissions perspective, reducing the use of hydrocarbon-based aerosol propellants indoors would likely have the largest impact.
Collapse
Affiliation(s)
- Aiden C Heeley-Hill
- Wolfson Atmospheric Chemistry Laboratories, University of York, York, YO10 5DD, UK
| | - Stuart K Grange
- Wolfson Atmospheric Chemistry Laboratories, University of York, York, YO10 5DD, UK
| | - Martyn W Ward
- Wolfson Atmospheric Chemistry Laboratories, University of York, York, YO10 5DD, UK
| | - Alastair C Lewis
- National Centre for Atmospheric Science, University of York, York, YO10 5DD, UK.
| | - Neil Owen
- Givaudan UK Ltd, Kennington Road, TN24 0LT Ashford, UK
| | | | - Gemma Hodgson
- QI Statistics, Overdene House, 49 Church Street, Theale, Berkshire RG7 5BX, UK
| | - Greg Adamson
- Givaudan Fragrances Corp., 717 Ridgedale Ave, East Hanover, New Jersey 07936, USA
| |
Collapse
|
27
|
Comprehensive Two-Dimensional Gas Chromatography-Mass Spectrometry Analysis of Exhaled Breath Compounds after Whole Grain Diets. Molecules 2021; 26:molecules26092667. [PMID: 34063191 PMCID: PMC8125105 DOI: 10.3390/molecules26092667] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 12/18/2022] Open
Abstract
Exhaled breath is a potential noninvasive matrix to give new information about metabolic effects of diets. In this pilot study, non-targeted analysis of exhaled breath volatile organic compounds (VOCs) was made by comprehensive two-dimensional gas chromatography-mass spectrometry (GCxGC-MS) to explore compounds relating to whole grain (WG) diets. Nine healthy subjects participated in the dietary intervention with parallel crossover design, consisting of two high-fiber diets containing whole grain rye bread (WGR) or whole grain wheat bread (WGW) and 1-week control diets with refined wheat bread (WW) before both diet periods. Large interindividual differences were detected in the VOC composition. About 260 VOCs were detected from exhaled breath samples, in which 40 of the compounds were present in more than half of the samples. Various derivatives of benzoic acid and phenolic compounds, as well as some furanones existed in exhaled breath samples only after the WG diets, making them interesting compounds to study further.
Collapse
|
28
|
Mule NM, Patil DD, Kaur M. A comprehensive survey on investigation techniques of exhaled breath (EB) for diagnosis of diseases in human body. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100715] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
29
|
Kalidoss R, Surya VJ, Sivalingam Y. Recent Progress in Graphene Derivatives/Metal Oxides Binary Nanocomposites Based Chemi-resistive Sensors for Disease Diagnosis by Breath Analysis. CURR ANAL CHEM 2020. [DOI: 10.2174/1573411017999201125203955] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background::
The scientific and clinical interest of breath analysis for non-invasive disease diagnosis has been focused by the scientific community over the past decade. This was due to the exhalation of prominent volatile organic compounds (VOCs) corresponding to the metabolic activities in the body and their concentration variation. To identify these biomarkers, various analytical techniques have been used in the past and the threshold concentration was established between a healthy and diseased state. Subsequently, various nanomaterials-based gas sensors were explored for their demand in quantifying these biomarkers for real-time, low cost and portable breathalyzers along with the essential sensor performances.
Methods::
We focus on the classification of graphene derivatives and their composites’ gas sensing efficiency for the application in the development of breathalyzers. The review begins with the feasibility of the application of nanomaterial gas sensors for healthcare applications. Then, we systematically report the gas sensing performance of various graphene derivatives/semiconductor metal oxides (SMO) binary nanocomposites and their optimizing strategies in selective detection of biomarkers specific to diseases. Finally, we provide insights on the challenges, opportunity and future research directions for the development of breathalyzers using other graphene derivatives/SMO binary nanocomposites.
Results::
On the basis of these analyses, graphene and its derivatives/metal oxides based binary nanocomposites have been a choice for gas sensing material owing to their high electrical conductivity and extraordinary thickness-dependent physicochemical properties. Moreover, the presence of oxygen vacancies in SMO does not only alter the conductivity but also accelerates the carrier transport rate and influence the adsorption behavior of target analyte on the sensing materials. Hence researchers are exploring the search of ultrathin graphene and metal oxide counterpart for high sensing performances.
Conclusion::
Their impressive properties compared to their bulk counterpart have been uncovered towards sensitive and selective detection of biomarkers for its use in portable breathalyzers.
Collapse
Affiliation(s)
- Ramji Kalidoss
- Department of Biomedical Engineering, Bharath Institute of Higher Education and Research, Selaiyur, 600073, Tamil Nadu,, India
| | - Velappa Jayaraman Surya
- Department of Physics and Nanotechnology, Novel, Advanced, and Applied Materials (NAAM) Laboratory, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu,, India
| | - Yuvaraj Sivalingam
- Department of Physics and Nanotechnology, Laboratory for Sensors, Energy and Electronic Devices (Lab SEED), SRM Institute of Science & Technology, Kattankulathur, Tamil Nadu 603203,, India
| |
Collapse
|
30
|
Kalidoss R, Umapathy S, Kothalam R, Sakthivelu U. Adsorption kinetics feature extraction from breathprint obtained by graphene based sensors for diabetes diagnosis. J Breath Res 2020; 15:016005. [PMID: 33049727 DOI: 10.1088/1752-7163/abc09b] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The correlation between blood glucose and breath acetone suggested by several studies has spurred the research community to develop an electronic (e-nose) for diabetes diagnosis. Herein, we have validated the in-house graphene based sensors with known acetone concentration. The sensor performances such as sensitivity, selectivity and stability (SSS) suggested their potential use in acquiring breath print. The 10% higher mean saturation voltage for 30 diabetic subjects ensured a discrimination accuracy of 65% with a positive correlation (r = 0.88) between biochemically measured and non-invasively estimated (glycated haemoglobin) HbA1c. For the improvement of classification rate, thirteen features associated with the adsorption kinetics were extracted from the breathprint from each of the three sensors. The features given as an input to the Naïve Bayes classification model fetched an accuracy of 68.33%. Elimination of redundant features by distinction index and one-R feature ranking algorithm results in Naïve Bayes algorithm with improved performances. The success rate has improved to 70% using the subset of features ranked by one-R algorithm. These results indicated the use of feature ranking algorithms and prediction models for the improvement in accuracy of our in-house fabricated graphene based sensors.
Collapse
Affiliation(s)
- Ramji Kalidoss
- Department of Biomedical Engineering, College of Engineering and Technology, SRM Institute of Science & Technology, Tamil Nadu, Kattankulathur 603203, India. Department of Biomedical Engineering, Bharath Institute of Higher Education and Research, Chennai, Tamil Nadu 600073, India
| | | | | | | |
Collapse
|
31
|
Novel 1D/2D KWO/Ti3C2Tx Nanocomposite-Based Acetone Sensor for Diabetes Prevention and Monitoring. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040102] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The acetone content in the exhaled breath of individuals as a biomarker of diabetes has become widely studied as a non-invasive means of quantifying blood glucose levels. This calls for development of sensors for the quantitative analysis of trace concentration of acetone, which is presents in the human exhaled breath. Traditional gas detection systems, such as the Gas Chromatography/Mass Spectrometry and several types of chemiresistive sensors are currently being used for this purpose. However, these systems are known to have limitations of size, cost, response time, operating conditions, and consistent accuracy. An ideal breath acetone sensor should provide solutions to overcome the above limitations and provide good stability and reliability. It should be a simple and portable detection system of good sensitivity, selectivity that is low in terms of both cost and power consumption. To achieve this goal, in this paper, we report a new sensing nanomaterial made by nanocomposite, 1D KWO (K2W7O22) nanorods/2D Ti3C2Tx nanosheets, as the key component to design an acetone sensor. The preliminary result exhibits that the new nanocomposite has an improved response to acetone, with 10 times higher sensitivity comparing to KWO-based sensor, much better tolerance of humidity interference and enhanced stability for multiple months. By comparing with other nanomaterials: Ti3C2, KWO, and KWO/Ti3C2Tx nanocomposites with variable ratio of KWO and Ti3C2Tx from 1:1, 1:2, 1:5, 2:1, 4:1, and 9:1, the initial results confirm the potential of the novel KWO/Ti3C2 (2:1) nanocomposite to be an excellent sensing material for application in sensitive and selective detection of breath acetone for diabetics health care and prevention.
Collapse
|
32
|
Arakawa T, Aota T, Iitani K, Toma K, Iwasaki Y, Mitsubayashi K. Skin ethanol gas measurement system with a biochemical gas sensor and gas concentrator toward monitoring of blood volatile compounds. Talanta 2020; 219:121187. [PMID: 32887105 DOI: 10.1016/j.talanta.2020.121187] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 05/16/2020] [Accepted: 05/16/2020] [Indexed: 02/08/2023]
Abstract
We developed a biochemical gas sensor (bio-sniffer) using the enzymatic reaction of alcohol dehydrogenase (ADH) to target ethanol in skin gas. By introducing a gas concentrator using liquid nitrogen, we constructed a highly sensitive system for skin gas measurements. The ethanol bio-sniffer was built from an optical-fiber probe employing an ADH enzyme membrane, an UV-LED light source for excitation, and a photomultiplier tube. Ethanol was measured by detecting the autofluorescence of the coenzyme NADH due to the enzymatic reaction of ADH. We established a system for measuring concentrated gases by connecting the sensor with a gas concentrator and introducing concentrated skin gas to the sensing surface. This suppressed diffusion of the concentrated gases to achieve maximum fluorescence intensity by optimizing the measurement system. The calibration curve from obtained peak values showed ethanol gas can be measured over 1-3100 ppb, which included skin gas concentrations during alcohol consumption. Finally, when applied to measurements of ethanol in skin gas following alcohol consumption, the output was found to be dependent on concentration, similarly to using standard gases. Consecutive measurements were possible using periodic sampling with 6-min intervals for 180 min of monitoring. Skin ethanol concentrations rose from 20 min after consuming the alcohol, exhibited a peak value of 25 ppb skin gas ethanol at around 60 min, and gradually declined. Thus, the system can be used for non-invasive percutaneous evaluation of human volatile organic chemicals in blood.
Collapse
Affiliation(s)
- Takahiro Arakawa
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan.
| | - Takashi Aota
- Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan
| | - Kenta Iitani
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan; Postdoctoral Research Fellow PD, Japan Society for the Promotion of Science, 5-3-1 Kojimatchi, Chiyoda-ku, Tokyo 102-0083, Japan
| | - Koji Toma
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan
| | - Yasuhiko Iwasaki
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, Osaka, Japan
| | - Kohji Mitsubayashi
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo, Japan; Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
| |
Collapse
|
33
|
Zhou W, Huang C, Zou X, Lu Y, Xia L, Shen C, Chu Y. Modification of an atmospheric pressure photoionization source for online analysis of exhaled breath coupled with quadrupole time-of-flight mass spectrometry. Anal Bioanal Chem 2020; 412:3663-3671. [PMID: 32333078 DOI: 10.1007/s00216-020-02602-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 03/09/2020] [Accepted: 03/16/2020] [Indexed: 01/26/2023]
Abstract
Breath analysis is a promising method for metabolomics studies and clinical diagnosis, as it enables the observation of metabolites in a convenient and noninvasive way. In this work, an atmospheric pressure photoionization (APPI) source was modified for online analysis of exhaled breath by coupling with quadrupole time-of-flight mass spectrometry (QTOFMS). Three parameters, namely, the capillary voltage, the sampling flow and the curtain gas flow of the APPI source, were optimized. Five healthy volunteers, three males and two females, were enrolled to test the performance of modified APPI-QTOFMS by analyzing their exhaled breath. A total of 21 compounds were tentatively identified, and four metabolites, namely, dimethyl selenoxide, δ-valerolactam, hydroxymandelic acid and palmitic amide were detected in the exhaled breath for the first time. The result shows that modified APPI-QTOFMS can be used for the online study of exhaled breath. Graphical abstract.
Collapse
Affiliation(s)
- Wenzhao Zhou
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China.,Zhejiang Institute of Metrology, No.300 Xiasha Road, Hangzhou, 310018, Zhejiang, China
| | - Chaoqun Huang
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China.
| | - Xue Zou
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China
| | - Yan Lu
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China
| | - Lei Xia
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China
| | - Chengyin Shen
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China
| | - Yannan Chu
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, Anhui, China
| |
Collapse
|
34
|
Microbiota and Malodor-Etiology and Management. Int J Mol Sci 2020; 21:ijms21082886. [PMID: 32326126 PMCID: PMC7215946 DOI: 10.3390/ijms21082886] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 02/06/2023] Open
Abstract
Accumulating evidence indicates that microbiota plays a critical role in physiological processes in humans. However, it might also contribute to body malodor by producing numerous odorous molecules such as ammonia, volatile sulfur compounds or trimethylamine. Although malodor is commonly overlooked by physicians, it constitutes a major problem for many otherwise healthy people. Thus, this review aims to investigate most common causes of malodor and describe potential therapeutic options. We searched PUBMED and Google Scholar databases to identify the clinical and pre-clinical studies on bad body smell, malodor, halitosis and microbiota. Unpleasant smell might originate from the mouth, skin, urine or reproductive fluids and is usually caused by odorants that are produced by resident bacterial flora. The accumulation of odorous compounds might result from diet, specific composition of microbiota, as well as compromised function of the liver, intestines and kidneys. Evidence-based guidelines for management of body malodor are lacking and no universal treatment exists. However, the alleviation of the symptoms may be achieved by controlling the diet and physical elimination of bacteria and/or accumulated odorants.
Collapse
|
35
|
Shokrekhodaei M, Quinones S. Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1251. [PMID: 32106464 PMCID: PMC7085605 DOI: 10.3390/s20051251] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 02/22/2020] [Accepted: 02/23/2020] [Indexed: 12/12/2022]
Abstract
Annual deaths in the U.S. attributed to diabetes are expected to increase from 280,210 in 2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has made it one of the major public health challenges around the world. Better management of diabetes has the potential to decrease yearly medical costs and deaths associated with the disease. Non-invasive methods are in high demand to take the place of the traditional finger prick method as they can facilitate continuous glucose monitoring. Research groups have been trying for decades to develop functional commercial non-invasive glucose measurement devices. The challenges associated with non-invasive glucose monitoring are the many factors that contribute to inaccurate readings. We identify and address the experimental and physiological challenges and provide recommendations to pave the way for a systematic pathway to a solution. We have reviewed and categorized non-invasive glucose measurement methods based on: (1) the intrinsic properties of glucose, (2) blood/tissue properties and (3) breath acetone analysis. This approach highlights potential critical commonalities among the challenges that act as barriers to future progress. The focus here is on the pertinent physiological aspects, remaining challenges, recent advancements and the sensors that have reached acceptable clinical accuracy.
Collapse
Affiliation(s)
- Maryamsadat Shokrekhodaei
- Department of Electrical and Computer Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA
| | - Stella Quinones
- Department of Metallurgical, Materials and Biomedical Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA;
| |
Collapse
|
36
|
Cheng NY, Chuang HC, Shie RH, Liao WH, Hwang YH. Pilot Studies of VOC Exposure Profiles during Surgical Operations. Ann Work Expo Health 2020; 63:173-183. [PMID: 30551204 DOI: 10.1093/annweh/wxy099] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 10/23/2018] [Accepted: 11/12/2018] [Indexed: 01/09/2023] Open
Abstract
Volatile organic chemical exposure resulting from surgical operations is common in operating room personnel. The potential risk of long-term exposure to these low-level chemicals is always a concern. This study was conducted in an area hospital located in northern Taiwan to investigate the internal exposure scenario for operating room personnel. Breath samples were collected before and after surgery, whereas area samples were collected during the surgeries in process. There were 18 volatile organic compounds identified in the samples with gas chromatography-mass spectrometry. The average concentrations of sevoflurane (P = 0.0082), dimethyl sulfide (P = 0.0550), and methyl methacrylate (P = 0.0606) in breath samples collected after surgical operations were significantly higher compared to those obtained before surgical operations, whereas only slight elevations were present for benzene and hexamethyldisiloxane (P < 0.100). In addition, electrosurgical smoke-related chemicals, such as benzene, toluene, ethylbenzene, and m/p-xylene, also presented higher levels in operating room samples compared to the control area. Specifically, the findings in this preliminary study suggested the associations of elevated exposure to sevoflurane across various surgeries to methyl methacrylate with orthopedic surgery and to hexamethyldisiloxane with conventional electrosurgical units. Future study is warranted to explore the short-term high-level chemical exposure in operating rooms and to propose effective preventive measures accordingly to keep any exposure to chemicals at the lowest practical level.
Collapse
Affiliation(s)
- Nai-Yun Cheng
- Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, R.O.C.,Institute of Labor, Occupational Safety and Health, Ministry of Labor, Executive Yuan, Taipei, Taiwan, R.O.C
| | - Hsiao-Chi Chuang
- School of Respiratory Therapy, College of Medicine, Taipei Medical University, Taipei, Taiwan, R.O.C.,Division of Pulmonary Medicine, Department of Internal Medicine, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan, R.O.C
| | - Ruei-Hao Shie
- Industrial Technology Research Institute, Hsinchu, Taiwan, R.O.C
| | - Wei-Heng Liao
- Institute of Labor, Occupational Safety and Health, Ministry of Labor, Executive Yuan, Taipei, Taiwan, R.O.C
| | - Yaw-Huei Hwang
- Institute of Occupational Medicine and Industrial Hygiene, College of Public Health, National Taiwan University, Taipei, Taiwan, R.O.C.,Department of Public Health, College of Public Health, National Taiwan University, Taipei, Taiwan, R.O.C
| |
Collapse
|
37
|
Orr ME, Reveles KR, Yeh CK, Young EH, Han X. Can oral health and oral-derived biospecimens predict progression of dementia? Oral Dis 2020; 26:249-258. [PMID: 31541581 PMCID: PMC7031023 DOI: 10.1111/odi.13201] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 08/09/2019] [Accepted: 08/30/2019] [Indexed: 12/13/2022]
Abstract
Growing evidence indicates that oral health and brain health are interconnected. Declining cognition and dementia coincide with lack of self‐preservation, including oral hygiene. The oral microbiota plays an important role in maintaining oral health. Emerging evidence suggests a link between oral dysbiosis and cognitive decline in patients with Alzheimer's disease. This review showcases the recent advances connecting oral health and cognitive function during aging and the potential utility of oral‐derived biospecimens to inform on brain health. Collectively, experimental findings indicate that the connection between oral health and cognition cannot be underestimated; moreover, oral biospecimens are abundant and readily obtainable without invasive procedures, which may help inform on cognitive health.
Collapse
Affiliation(s)
- Miranda E Orr
- Barshop Institute for Longevity and Aging Studies, UT Health San Antonio, San Antonio, Texas.,Geriatric Research, Education & Clinical Center and Research Service, South Texas Veterans Health Care System, San Antonio, Texas.,Department of Medicine, UT Health San Antonio, San Antonio, Texas.,Biggs Institute for Alzheimer's and Neurodegenerative Diseases, UT Health San Antonio, San Antonio, Texas.,Gerontology and Geriatric Medicine, Sticht Center for Healthy Aging and Alzheimer's Prevention, Wake Forest School of Medicine, Winston-Salem, North Carolina
| | - Kelly R Reveles
- College of Pharmacy, The University of Texas at Austin, Austin, Texas.,Pharmacotherapy Education & Research Center, UT Health San Antonio, San Antonio, Texas
| | - Chih-Ko Yeh
- Barshop Institute for Longevity and Aging Studies, UT Health San Antonio, San Antonio, Texas.,Geriatric Research, Education & Clinical Center and Research Service, South Texas Veterans Health Care System, San Antonio, Texas.,Comprehensive Dentistry, School of Dentistry, UT Health San Antonio, San Antonio, Texas
| | - Eric H Young
- College of Pharmacy, The University of Texas at Austin, Austin, Texas.,Pharmacotherapy Education & Research Center, UT Health San Antonio, San Antonio, Texas
| | - Xianlin Han
- Barshop Institute for Longevity and Aging Studies, UT Health San Antonio, San Antonio, Texas.,Department of Medicine, UT Health San Antonio, San Antonio, Texas
| |
Collapse
|
38
|
Trefz P, Obermeier J, Lehbrink R, Schubert JK, Miekisch W, Fischer DC. Exhaled volatile substances in children suffering from type 1 diabetes mellitus: results from a cross-sectional study. Sci Rep 2019; 9:15707. [PMID: 31673076 PMCID: PMC6823423 DOI: 10.1038/s41598-019-52165-x] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Accepted: 10/10/2019] [Indexed: 02/06/2023] Open
Abstract
Monitoring metabolic adaptation to type 1 diabetes mellitus in children is challenging. Analysis of volatile organic compounds (VOCs) in exhaled breath is non-invasive and appears as a promising tool. However, data on breath VOC profiles in pediatric patients are limited. We conducted a cross-sectional study and applied quantitative analysis of exhaled VOCs in children suffering from type 1 diabetes mellitus (T1DM) (n = 53) and healthy controls (n = 60). Both groups were matched for sex and age. For breath gas analysis, a very sensitive direct mass spectrometric technique (PTR-TOF) was applied. The duration of disease, the mode of insulin application (continuous subcutaneous insulin infusion vs. multiple daily insulin injection) and long-term metabolic control were considered as classifiers in patients. The concentration of exhaled VOCs differed between T1DM patients and healthy children. In particular, T1DM patients exhaled significantly higher amounts of ethanol, isopropanol, dimethylsulfid, isoprene and pentanal compared to healthy controls (171, 1223, 19.6, 112 and 13.5 ppbV vs. 82.4, 784, 11.3, 49.6, and 5.30 ppbV). The most remarkable differences in concentrations were found in patients with poor metabolic control, i.e. those with a mean HbA1c above 8%. In conclusion, non-invasive breath testing may support the discovery of basic metabolic mechanisms and adaptation early in the progress of T1DM.
Collapse
Affiliation(s)
- Phillip Trefz
- Department of Anesthesiology and Intensive Care Medicine, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Rostock University Medical Centre, Rostock, Germany.
| | - Juliane Obermeier
- Department of Anesthesiology and Intensive Care Medicine, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Rostock University Medical Centre, Rostock, Germany
| | - Ruth Lehbrink
- Department of Pediatrics, Rostock University Medical Centre, Rostock, Germany
| | - Jochen K Schubert
- Department of Anesthesiology and Intensive Care Medicine, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Rostock University Medical Centre, Rostock, Germany
| | - Wolfram Miekisch
- Department of Anesthesiology and Intensive Care Medicine, Rostock Medical Breath Research Analytics and Technologies (ROMBAT), Rostock University Medical Centre, Rostock, Germany
| | | |
Collapse
|
39
|
Non-Invasive Assessment of Metabolic Adaptation in Paediatric Patients Suffering from Type 1 Diabetes Mellitus. J Clin Med 2019; 8:jcm8111797. [PMID: 31717811 PMCID: PMC6912469 DOI: 10.3390/jcm8111797] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 10/22/2019] [Accepted: 10/25/2019] [Indexed: 02/06/2023] Open
Abstract
An analysis of exhaled volatile organic compounds (VOC) may deliver systemic information quicker than available invasive techniques. Metabolic aberrations in pediatric type 1 diabetes (T1DM) are of high clinical importance and could be addressed via breathomics. Real-time breath analysis was combined with continuous glucose monitoring (CGM) and blood tests in children suffering from T1DM and age-matched healthy controls in a highly standardized setting. CGM and breath-resolved VOC analysis were performed every 5 minutes for 9 hours and blood was sampled at pre-defined time points. Per participant (n = 44) food intake and physical activity were identical and a total of 22 blood samples and 93 minutes of breath samples were investigated. The inter-individual variability of glucose, insulin, glucagon, leptin, and soluble leptin receptor relative to food intake differed distinctly between patients and controls. In T1DM patients, the exhaled amounts of acetone, 2-propanol, and pentanal correlated to glucose concentrations. Of note, the strength of these correlations strongly depended on the interval between food intake and breath sampling. Our data suggests that metabolic adaptation through postprandial hyperglycemia and related oxidative stress is immediately reflected in exhaled breath VOC concentrations. Clinical translations of our findings may enable point-of-care applicability of online breath analysis towards personalized medicine.
Collapse
|
40
|
Li B, Zou X, Wang H, Lu Y, Shen C, Chu Y. Standardization study of expiratory conditions for on-line breath testing by proton transfer reaction mass spectrometry. Anal Biochem 2019; 581:113344. [DOI: 10.1016/j.ab.2019.113344] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 06/19/2019] [Accepted: 06/19/2019] [Indexed: 12/14/2022]
|
41
|
Iitani K, Toma K, Arakawa T, Mitsubayashi K. Ultrasensitive Sniff-Cam for Biofluorometric-Imaging of Breath Ethanol Caused by Metabolism of Intestinal Flora. Anal Chem 2019; 91:9458-9465. [PMID: 31287286 DOI: 10.1021/acs.analchem.8b05840] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
We developed a gas-imaging system (sniff-cam) for gaseous ethanol (EtOH) with improved sensitivity. The sniff-cam was applied to measure the extremely low concentration distribution of breath EtOH without the consumption of alcohol, which is related to the activity of the oral or gut bacterial flora. A ring-type ultraviolet-light-emitting diode was mounted around a camera lens as an excitation light source, which enabled simultaneous excitation and imaging of the fluorescence. In the EtOH sniff-cam, a nicotinamide adenine dinucleotide (NAD)-dependent alcohol dehydrogenase (ADH) was used to catalyze the redox reaction between EtOH and the oxidized form of NAD (NAD+). Upon application of gaseous EtOH to the ADH-immobilized mesh that was soaked in an NAD+ solution and placed in front of the camera, NADH was produced through an ADH-mediated reaction. NADH expresses fluorescence at an emission wavelength of 490 nm and excitation wavelength of 340 nm. Thus, the concentration distribution of EtOH was visualized by measuring the distribution of the fluorescence light intensity from NADH on the ADH-immobilized mesh surface. First, a comparison of image analysis methods based on the red-green-blue color (RGB) images and the optimization of the buffer pH and NAD+ solution concentration was performed. The new sniff-cam showed a 25-fold greater sensitivity and broader dynamic range (20.6-300000 ppb) in comparison to those of the previously fabricated sniff-cam. Finally, we measured the concentration distribution of breath EtOH without alcohol consumption using the improved sniff-cam and obtained a value of 116.2 ± 35.7 ppb (n = 10).
Collapse
Affiliation(s)
- Kenta Iitani
- Postdoctoral Research Fellow PD , Japan Society for the Promotion of Science , 5-3-1 Kojimatchi , Chiyoda-ku, Tokyo 102-0083 , Japan.,Department of Life Science and Medical Bioscience, Graduate School of Advanced Science and Engineering , Waseda University (TWIns) , 2-2 Wakamatsu-cho , Shinjuku-ku, Tokyo 162-8480 , Japan.,Graduate School of Medical and Dental Sciences , Tokyo Medical and Dental University , 1-5-45 Yushima , Bunkyo-ku, Tokyo 113-8510 , Japan
| | - Koji Toma
- Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai , Chiyoda-ku, Tokyo 101-0062 , Japan
| | - Takahiro Arakawa
- Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai , Chiyoda-ku, Tokyo 101-0062 , Japan
| | - Kohji Mitsubayashi
- Graduate School of Medical and Dental Sciences , Tokyo Medical and Dental University , 1-5-45 Yushima , Bunkyo-ku, Tokyo 113-8510 , Japan.,Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering , Tokyo Medical and Dental University , 2-3-10 Kanda-Surugadai , Chiyoda-ku, Tokyo 101-0062 , Japan
| |
Collapse
|
42
|
Zhou W, Hong Y, Zou X, Xia L, Lu Y, Shen C, Huang C, Chu Y. Analysis of Nitrogen-containing Compounds in Mouth-exhaled Breath by Electrospray Ionization Quadrupole Time-of-Flight Mass Spectrometry. ANAL SCI 2019; 35:1155-1159. [PMID: 31178549 DOI: 10.2116/analsci.19n018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Nitrogen-containing compounds are important components in human breath. However, their origins have not yet been clearly understood. In this study, a modified electrospray ionization (ESI) source coupling with quadrupole time-of-flight mass spectrometry has been used for breath analysis. Fourteen nitrogen-containing compounds were identified in mouth-exhaled breath, and 10 of them were from the oral cavity and oropharynx. Moreover, 8 of these nitrogen-containing compounds were recognized as endogenous metabolites. This result provides important clues for exploring the biological origins of these nitrogen-containing compounds. Observation of the ion suppression phenomenon also indicates that breath analysis should be carried out after clearing of the oral cavity and oropharynx, or directly through nose-breathing to eliminate the influence of those nitrogen-containing compounds from the oral cavity.
Collapse
Affiliation(s)
- Wenzhao Zhou
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Yan Hong
- School of Electrical and Information Engineering, Anhui University of Science and Technology
| | - Xue Zou
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Lei Xia
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Yan Lu
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Chengyin Shen
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Chaoqun Huang
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| | - Yannan Chu
- Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
| |
Collapse
|
43
|
Boubin M, Shrestha S. Microcontroller Implementation of Support Vector Machine for Detecting Blood Glucose Levels Using Breath Volatile Organic Compounds. SENSORS (BASEL, SWITZERLAND) 2019; 19:E2283. [PMID: 31108929 PMCID: PMC6567346 DOI: 10.3390/s19102283] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/14/2019] [Accepted: 05/15/2019] [Indexed: 01/22/2023]
Abstract
This paper presents an embedded system-based solution for sensor arrays to estimate blood glucose levels from volatile organic compounds (VOCs) in a patient's breath. Support vector machine (SVM) was trained on a general-purpose computer using an existing SVM library. A training model, optimized to achieve the most accurate results, was implemented in a microcontroller with an ATMega microprocessor. Training and testing was conducted using artificial breath that mimics known VOC footprints of high and low blood glucose levels. The embedded solution was able to correctly categorize the corresponding glucose levels of the artificial breath samples with 97.1% accuracy. The presented results make a significant contribution toward the development of a portable device for detecting blood glucose levels from a patient's breath.
Collapse
Affiliation(s)
- Matthew Boubin
- Intelligent Systems Laboratory, Department of Engineering Science, Sonoma State University, Rohnert Park, CA 94928, USA.
- Department of Electrical and Computer Engineering, Miami University, Oxford, OH 45056, USA.
| | - Sudhir Shrestha
- Intelligent Systems Laboratory, Department of Engineering Science, Sonoma State University, Rohnert Park, CA 94928, USA.
| |
Collapse
|
44
|
Miolo G, Basile D, Carretta A, Santeufemia DA, Steffan A, Corona G. The metabolomic scent of cancer disease progression in soft tissue sarcoma: A case report. Int J Biol Markers 2019; 34:205-209. [PMID: 30852948 DOI: 10.1177/1724600818817316] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The purpose of this case report is to describe the potential that metabolomics breath analysis may have in cancer disease monitoring. The advances in mass spectrometry instrumentation allow the accurate real-time analysis of volatile metabolites exhaled in the breath. The application of such non-invasive devices may provide innovative and complementary monitoring of the physio-pathological conditions of cancer patients. CASE PRESENTATION A 59-year-old Caucasian woman with spindle cell malignant mesenchymal sarcoma of the presacral region started a first-line therapy with non-pegylated liposomal doxorubicin and ifosfamide associated with pelvic radiant treatment. After two cycles of chemotherapy plus radiotherapy, a significant pulmonary disease progression was reported. Thus, a second-line therapy with trabectedin was administered. However, after only two cycles of treatment a re-staging computed tomography scan reported further cancer disease progression of the target pulmonary lesions as well as occurrence of new satellite bilateral nodules. Real-time analysis of breath exhaled volatile organic compounds, performed by select ion flow tube mass spectrometry (SIFT-MS) during the follow-up of the patient, showed a specific metabolic pattern not observed in the breath of other soft tissue sarcoma patients who achieved clinical benefit from the treatments. CONCLUSIONS This case report revealed the importance of the non-invasive real-time volatile organic compounds breath analysis to distinguish individual specific chemo-resistance phenotypes among soft tissue sarcoma patients. Such observation seems to suggest that breath metabolomics may be particularly useful for monitoring cancer disease progression in soft tissue sarcoma patients where only cost-effective diagnostic tools, such as positron emission tomography and computed tomography, are available.
Collapse
Affiliation(s)
- Gianmaria Miolo
- 1 Medical and Preventive Oncology Unit, Centro di Riferimento Oncologico di Aviano (CRO), IRCCS, Aviano, Italy
| | - Debora Basile
- 1 Medical and Preventive Oncology Unit, Centro di Riferimento Oncologico di Aviano (CRO), IRCCS, Aviano, Italy.,2 School of Medical Oncology, University of Udine, Udine, Italy
| | | | | | - Agostino Steffan
- 5 Immunopathology and Cancer Biomarkers Unit, Centro di Riferimento Oncologico di Aviano (CRO), IRCCS, Aviano, Italy
| | - Giuseppe Corona
- 5 Immunopathology and Cancer Biomarkers Unit, Centro di Riferimento Oncologico di Aviano (CRO), IRCCS, Aviano, Italy
| |
Collapse
|
45
|
Romero KI, Fernandez-Maestre R. Ion mobility spectrometry: the diagnostic tool of third millennium medicine. Rev Assoc Med Bras (1992) 2019; 64:861-868. [PMID: 30673009 DOI: 10.1590/1806-9282.64.09.861] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 01/13/2018] [Indexed: 11/22/2022] Open
Abstract
Ion mobility spectrometry (IMS) is a fast, low cost, portable, and sensitive technique that separates ions in a drift tube under the influence of an electric field according to their size and shape. IMS represents a non-invasive and reliable instrumental alternative for the diagnosis of different diseases through the analysis of volatile metabolites in biological samples. IMS has applications in medicine in the study of volatile compounds for the non-invasive diagnose of bronchial carcinoma, chronic obstructive pulmonary disease, and other diseases analysing breath, urine, blood, faeces, and other biological samples. This technique has been used to study complex mixtures such as proteomes, metabolomes, complete organisms like bacteria and viruses, monitor anaesthetic agents, determine drugs, pharmaceuticals, and volatile compounds in human body fluids, and others. Pharmaceutical applications include analysis of over-the-counter-drugs, quality assessment, and cleaning verification. Medical practice needs non-invasive, robust, secure, fast, real-time, and low-cost methods with high sensitivity and compact size instruments to diagnose different diseases and IMS is the diagnostic tool that meets all these requirements of the Medicine of the future.
Collapse
Affiliation(s)
- Katiuska I Romero
- . Medical Subdirector, Organización Clínica Bonnadona Prevenir, Barranquilla, Atlantico, Colombia
| | | |
Collapse
|
46
|
Yilmaz T, Foster R, Hao Y. Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels. Diagnostics (Basel) 2019; 9:diagnostics9010006. [PMID: 30626128 PMCID: PMC6468903 DOI: 10.3390/diagnostics9010006] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 12/13/2018] [Accepted: 12/21/2018] [Indexed: 12/13/2022] Open
Abstract
This paper reviews non-invasive blood glucose measurements via dielectric spectroscopy at microwave frequencies presented in the literature. The intent is to clarify the key challenges that must be overcome if this approach is to work, to suggest some possible ways towards addressing these challenges and to contribute towards prevention of unnecessary ‘reinvention of the wheel’.
Collapse
Affiliation(s)
- Tuba Yilmaz
- Department of Electronics and Communication Engineering, Istanbul Technical University, 34469 Istanbul, Turkey.
| | - Robert Foster
- Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Birmingham B15 2TT, UK.
| | - Yang Hao
- School of Electronic Engineering and Computer Science, Queen Mary University of London, London E1 4NS, UK.
| |
Collapse
|
47
|
ZIF Nanocrystal-Based Surface Acoustic Wave (SAW) Electronic Nose to Detect Diabetes in Human Breath. BIOSENSORS-BASEL 2018; 9:bios9010004. [PMID: 30587840 PMCID: PMC6468395 DOI: 10.3390/bios9010004] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Revised: 12/14/2018] [Accepted: 12/21/2018] [Indexed: 11/18/2022]
Abstract
In the present work, a novel, portable and innovative eNose composed of a surface acoustic wave (SAW) sensor array based on zeolitic imidazolate frameworks, ZIF-8 and ZIF-67 nanocrystals (pure and combined with gold nanoparticles), as sensitive layers has been tested as a non-invasive system to detect different disease markers, such as acetone, ethanol and ammonia, related to the diagnosis and control of diabetes mellitus through exhaled breath. The sensors have been prepared by spin coating, achieving continuous sensitive layers at the surface of the SAW device. Low concentrations (5 ppm, 10 ppm and 25 ppm) of the marker analytes were measured, obtaining high sensitivities, good reproducibility, short time response and fast signal recovery.
Collapse
|
48
|
Development of an analytical chip for detecting acetone using a reaction between acetone and 2,4-dinitrophenylhidrazine in a porous glass. Microchem J 2018. [DOI: 10.1016/j.microc.2018.05.041] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
49
|
Broza YY, Vishinkin R, Barash O, Nakhleh MK, Haick H. Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation. Chem Soc Rev 2018; 47:4781-4859. [PMID: 29888356 DOI: 10.1039/c8cs00317c] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
This article is an overview of the present and ongoing developments in the field of nanomaterial-based sensors for enabling fast, relatively inexpensive and minimally (or non-) invasive diagnostics of health conditions with follow-up by detecting volatile organic compounds (VOCs) excreted from one or combination of human body fluids and tissues (e.g., blood, urine, breath, skin). Part of the review provides a didactic examination of the concepts and approaches related to emerging sensing materials and transduction techniques linked with the VOC-based non-invasive medical evaluations. We also present and discuss diverse characteristics of these innovative sensors, such as their mode of operation, sensitivity, selectivity and response time, as well as the major approaches proposed for enhancing their ability as hybrid sensors to afford multidimensional sensing and information-based sensing. The other parts of the review give an updated compilation of the past and currently available VOC-based sensors for disease diagnostics. This compilation summarizes all VOCs identified in relation to sickness and sampling origin that links these data with advanced nanomaterial-based sensing technologies. Both strength and pitfalls are discussed and criticized, particularly from the perspective of the information and communication era. Further ideas regarding improvement of sensors, sensor arrays, sensing devices and the proposed workflow are also included.
Collapse
Affiliation(s)
- Yoav Y Broza
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion - Israel Institute of Technology, Haifa 3200003, Israel.
| | | | | | | | | |
Collapse
|
50
|
Zhou X, Wang J, Wang Z, Bian Y, Wang Y, Han N, Chen Y. Transilient Response to Acetone Gas Using the Interlocking p+n Field-Effect Transistor Circuit. SENSORS 2018; 18:s18061914. [PMID: 29895805 PMCID: PMC6021865 DOI: 10.3390/s18061914] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 06/04/2018] [Accepted: 06/05/2018] [Indexed: 11/16/2022]
Abstract
Low concentration acetone gas detection is significantly important for diabetes diagnosis as 1.8⁻10 ppm of acetone exists in exhaled breath from diabetes patients. A new interlocking p+n field-effect transistor (FET) circuit has been proposed for Mn-doped ZnO nanoparticles (MZO) to detect the acetone gas at low concentration, especially close to 1.8 ppm. It is noteworthy that MZO in this interlocking amplification circuit shows a low voltage signal of <0.3 V to the acetone <2 ppm while it displays a transilient response with voltage signal >4.0 V to >2 ppm acetone. In other words, the response to acetone from 1 ppm to 2 ppm increases by ~1233%, which is competent to separate diabetic patients from healthy people. Moreover, the response to 2 ppm acetone is hardly influenced by high relative humidity of 85%. In the meanwhile, MZO in this interlocking circuit possesses a high acetone selectivity compared to formaldehyde, acetaldehyde, toluene and ethanol, suggesting a promising technology for the widespread qualitative screening of diabetes. Importantly, this interlocking circuit is also applicable to other types of metal oxide semiconductor gas sensors. The resistance jump of p- and n-FETs induced by the change of their gate voltages is deemed to make this interlocking circuit produce the transilient response.
Collapse
Affiliation(s)
- Xinyuan Zhou
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
- College of Chemical Engineering, University of Chinese Academy of Sciences, No. 19A Yuquan Road, Beijing 100049, China.
- Center for Excellence in Regional Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China.
| | - Jinxiao Wang
- College of Materials Science and Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
| | - Zhou Wang
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
| | - Yuzhi Bian
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
- College of Chemical Engineering, University of Chinese Academy of Sciences, No. 19A Yuquan Road, Beijing 100049, China.
| | - Ying Wang
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
| | - Ning Han
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
- Center for Excellence in Regional Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China.
| | - Yunfa Chen
- State Key Laboratory of Multiphase Complex Systems, Institute of Process Engineering, Chinese Academy of Sciences, Beijing 100190, China.
- Center for Excellence in Regional Atmospheric Environment, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China.
| |
Collapse
|