1
|
van der Waals MJ, van Bel N, van Charante F, van Rijn J, van der Veen A, van der Wielen PWJJ. Alternative for HPC22 after repairs in the drinking water distribution system. WATER RESEARCH 2024; 265:122264. [PMID: 39173355 DOI: 10.1016/j.watres.2024.122264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Revised: 08/08/2024] [Accepted: 08/12/2024] [Indexed: 08/24/2024]
Abstract
There is a risk of contamination by (pathogenic) microorganisms from the outside environment into the drinking water during maintenance or pipe breaches in the drinking water distribution system (DWDS) and, consequently, the drinking water distributed to consumers may result in possible detrimental effects on public health. Traditional time-consuming microbiological testing is, therefore, performed to confirm drinking water is not microbially contaminated. This is done by culturing methods of the faecal indicators Escherichia coli, intestinal enterococci and the technical parameters coliform bacteria and heterotrophic plate counts at 22 °C (HPC22). In this study, fast methods (adenosine triphosphate (ATP), flow cytometry, enzyme activity and qPCR) were compared as an alternative for HPC22. Using dilution series and field samples, ATP (ATPtotal-lab and ATPcell-mob) and enzymatic activity (ALP-2) methods proved to be the more reliable and sensitive than flow cytometry and qPCR methods for detecting microbiological contaminations in drinking water. Significant (p < 0.05) and relatively strong correlations (R2 = 0.61-0.76) were obtained between HPC22 and both ATP methods, enzyme activity and qPCR parameters, but relations with flow cytometry were weak (R2 = 0.24 - 0.52). The samples taken after repairs or a calamity from the DWDS showed in general limited variation in the HPC22 count and were in most cases below the guidance level of 1,000 CFU/mL. We recommend that the best performing alternative methods, i.e. ATPtotal-lab and ATPcell-mob and ALP-2, should be included next to HPC22 in additional field studies to further test and compare these methods to be able to decide which fast method can replace HPC22 analysis after maintenance work in the DWDS.
Collapse
Affiliation(s)
| | - Nikki van Bel
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands.
| | - Frits van Charante
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | - Jeroen van Rijn
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | - Anita van der Veen
- KWR Water Research Institute, Groningenhaven 7, Nieuwegein, 3433 PE, the Netherlands
| | | |
Collapse
|
2
|
Dowdell KS, Potgieter SC, Olsen K, Lee S, Vedrin M, Caverly LJ, LiPuma JJ, Raskin L. Source-to-tap investigation of the occurrence of nontuberculous mycobacteria in a full-scale chloraminated drinking water system. Appl Environ Microbiol 2024; 90:e0060924. [PMID: 39109876 PMCID: PMC11409651 DOI: 10.1128/aem.00609-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 07/08/2024] [Indexed: 09/19/2024] Open
Abstract
Nontuberculous mycobacteria (NTM) in drinking water are a significant public health concern. However, an incomplete understanding of the factors that influence the occurrence of NTM in drinking water limits our ability to characterize risk and prevent infection. This study sought to evaluate the influence of season and water treatment, distribution, and stagnation on NTM in drinking water. Samples were collected source-to-tap in a full-scale, chloraminated drinking water system approximately monthly from December 2019 to November 2020. NTM were characterized using culture-dependent (plate culture with matrix-assisted laser desorption ionization-time-of-flight mass spectrometry [MALDI-TOF MS] isolate analysis) and culture-independent methods (quantitative PCR and genome-resolved metagenomics). Sampling locations included source waters, three locations within the treatment plant, and five buildings receiving water from the distribution system. Building plumbing samples consisted of first draw, 5-min flush, and full flush cold-water samples. As the study took place during the COVID-19 pandemic, the influence of reduced water usage in three of the five buildings was also investigated. The highest NTM densities source-to-tap were found in the summer first draw building water samples (107 gene copies/L), which also had the lowest monochloramine concentrations. Flushing was found to be effective for reducing NTM and restoring disinfectant residuals, though flush times necessary to improve water quality varied by building. Clinically relevant NTM species, including Mycobacterium avium, were recovered via plate culture, with increased occurrence observed in buildings with higher water age. Four of five NTM metagenome-assembled genomes were identified to the species level and matched identified isolates.IMPORTANCENTM infections are increasing in prevalence, difficult to treat, and associated with high morbidity and mortality rates. Our lack of understanding of the factors that influence NTM occurrence in drinking water limits our ability to prevent infections, accurately characterize risk, and focus remediation efforts. In this study, we comprehensively evaluated NTM in a full-scale drinking water system, showing that various steps in treatment and distribution influence NTM presence. Stagnant building water contained the highest NTM densities source-to-tap and was associated with low disinfectant residuals. We illustrated the differences in NTM detection and characterization obtained from culture-based and culture-independent methods, highlighting the complementarity between these approaches. We demonstrated that focusing NTM mitigation efforts in building plumbing systems, which have the highest NTM densities source-to-tap, has potential for immediate positive effects. We also identified steps during treatment that increase NTM levels, which provides beneficial information for utilities seeking to reduce NTM in finished water.
Collapse
Affiliation(s)
- Katherine S. Dowdell
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Sarah C. Potgieter
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Kirk Olsen
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Soojung Lee
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Matthew Vedrin
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Lindsay J. Caverly
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, Michigan, USA
| | - John J. LiPuma
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, Michigan, USA
| | - Lutgarde Raskin
- Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
3
|
Campbell AM, Willis K, Parsons E. Forecasting climate-associated non-tuberculous mycobacteria (NTM) infections in the UK using international surveillance data and machine learning. PLOS GLOBAL PUBLIC HEALTH 2024; 4:e0003262. [PMID: 39159199 PMCID: PMC11332936 DOI: 10.1371/journal.pgph.0003262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Accepted: 07/17/2024] [Indexed: 08/21/2024]
Abstract
Nontuberculous mycobacteria (NTM) cause skin and lung infections, have high mortality rates, and are resistant to a range of antibiotics and water treatment methods. As NTM reside in environmental reservoirs, they are sensitive to environmental conditions. The suitability of their environmental reservoirs can increase as a result of climate change, subsequently increasing environmental exposure and infection rates. NTM infections are not generally notifiable, including in the UK, but sustained increases have been observed in regions that report NTM infection rates. To assess the burden of NTM infections in the UK under projected climate change, we examined the relationship between climate variables and available NTM surveillance data internationally. Statistically significant increases were found in regions where NTM infections are notifiable, which were positively associated with increased precipitation and temperatures. A random forest regressor was trained using supervised learning from international NTM surveillance data and linked climate variables. The random forest model was applied to UK climate projections, projecting a 6.2% increase in NTM infection rates over the next 10 years, with notable regional variation. Our random forest model predicts that the forecasted impacts of climate change in the UK, including increasing temperatures and frequency of heavy rainfall, will lead to increases in NTM infection rates. Robust surveillance in the future is necessary to increase data available to train models, increasing our predictive power in forecasting climate-associated NTM trends. Our results highlight a novel aspect of how climate change will impact health outcomes in the UK.
Collapse
Affiliation(s)
- Amy Marie Campbell
- Global Assessment and Emerging Hazards Division, UK Health Security Agency, London, United Kingdom
| | - Katy Willis
- Global Assessment and Emerging Hazards Division, UK Health Security Agency, London, United Kingdom
| | - Edward Parsons
- Global Assessment and Emerging Hazards Division, UK Health Security Agency, London, United Kingdom
| |
Collapse
|
4
|
Heijnen L, de Vries HJ, van Pelt G, Stroobach E, Atsma A, Vranken J, De Maeyer K, Vissers L, Medema G. Qualitative detection of E. coli in distributed drinking water using real-time reverse transcription PCR targeting 16S rRNA: Validation and practical experiences. WATER RESEARCH 2024; 259:121843. [PMID: 38824794 DOI: 10.1016/j.watres.2024.121843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 05/17/2024] [Accepted: 05/27/2024] [Indexed: 06/04/2024]
Abstract
Escherichia coli (E. coli) plays a central role as an indicator for fecal contamination to predict the possible presence of microbial pathogens in drinking water. Current detection methods for E. coli are based on time-consuming culture-based techniques. There is a strong need for methods to detect fecal contamination rapidly in distributed drinking water to prevent outbreaks of waterborne disease and support water utilities to efficiently manage their operations like actions to repair or maintain distribution pipes, to minimize impact on consumers. This study describes the validation and application of a qualitative real time reverse transcription PCR (RT-PCR) method targeting 16S ribosomal RNA (rRNA) for rapid detection of E. coli in distributed drinking water. The RT-PCR assay targets 16S rRNA, a highly abundant RNA in viable cells, enabling robust detection at the required sensitivity of 1 CFU/100 ml. The validation was performed by comparing the RT-PCR method with the culture-based chromogenic reference method (CCA) using the protocol and criteria described in ISO 16,140-2:2016. The validation demonstrated that this RT-PCR method can be used to specifically detect E. coli in a broad range of drinking water samples with at least the same limit of detection as the culture method (Relative Limit Of Detection = 0.75, range 0.43-1.43). The inclusivity study showed that the RT-PCR method was able to detect a broad range of E. coli strains derived from different sources and geographic areas, including pathogenic serotype O157 strains that are not detected with the culture method. The exclusivity study determined that other bacterial genera are not detected with this RT-PCR. However, Escherichia fergusonii was detected and, based on "in silico" analysis, it is expected that also E. albertii and E. marmotae and Shigella species will be detectable using this RT-PCR. An interlaboratory study confirmed that the RT-PCR and culture method have comparable sensitivities when tested by different participants at different laboratories. The application of RT-PCR to confirm the hygienic quality of distributed drinking water after actions to repair or maintain distribution pipes was compared with the culture method on 8076 routine samples, analyzed by the drinking water laboratories in the Netherlands. This comparison study showed a 96.4 % agreement between RT-PCR and culture. In 3.3 % of the samples E. coli was detected with RT-PCR and not with the culture method and in 0.1 % of the samples E. coli was only detected by culture confirming either a higher sensitivity for RT-PCR or the detection of RNA from uncultivable cells. Finally, the application of RT-PCR was highlighted during a contamination event in Belgium where we demonstrate the potency of RT-PCR as a tool to rapidly monitor the spread of microbial contamination and to monitor the effect of measures to remove the contamination This is the first fully validated rapid nucleic based method for detection of E. coli in distributed drinking water. These results demonstrate that this RT-PCR method can be used as a rapid alternative to the culture method to monitor E. coli in distributed drinking water. However, it should be emphasized that nucleic acid based detection methods rely on highly different detection principles (detection of captured nucleic acids present in a sample) than culture base methods (presence of cells cultivable on a selective medium) resulting in occasional different analysis results. Varying treatment and disinfection steps (UV, chlorine, monochloramine, Ozone) or environmental factors (decay) can influence the results and cause differences between RT-PCR and culture methods.
Collapse
Affiliation(s)
- Leo Heijnen
- KWR Water Research Institute, Nieuwegein, the Netherlands.
| | | | | | | | - Adrie Atsma
- Vitens Water Expertise Center, Leeuwarden, the Netherlands
| | | | | | - Liesbeth Vissers
- AQZ (Aqualab Zuid), Werkendam, the Netherlands; Brabant Water, 's-Hertogenbosch, the Netherlands
| | - Gertjan Medema
- KWR Water Research Institute, Nieuwegein, the Netherlands; Delft University of Technology, Delft, the Netherlands
| |
Collapse
|
5
|
Maranha A, Alarico S, Nunes-Costa D, Melo-Marques I, Roxo I, Castanheira P, Caramelo O, Empadinhas N. Drinking Water Microbiota, Entero-Mammary Pathways, and Breast Cancer: Focus on Nontuberculous Mycobacteria. Microorganisms 2024; 12:1425. [PMID: 39065193 PMCID: PMC11279143 DOI: 10.3390/microorganisms12071425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/03/2024] [Accepted: 07/09/2024] [Indexed: 07/28/2024] Open
Abstract
The prospect of drinking water serving as a conduit for gut bacteria, artificially selected by disinfection strategies and a lack of monitoring at the point of use, is concerning. Certain opportunistic pathogens, notably some nontuberculous mycobacteria (NTM), often exceed coliform bacteria levels in drinking water, posing safety risks. NTM and other microbiota resist chlorination and thrive in plumbing systems. When inhaled, opportunistic NTM can infect the lungs of immunocompromised or chronically ill patients and the elderly, primarily postmenopausal women. When ingested with drinking water, NTM often survive stomach acidity, reach the intestines, and migrate to other organs using immune cells as vehicles, potentially colonizing tumor tissue, including in breast cancer. The link between the microbiome and cancer is not new, yet the recognition of intratumoral microbiomes is a recent development. Breast cancer risk rises with age, and NTM infections have emerged as a concern among breast cancer patients. In addition to studies hinting at a potential association between chronic NTM infections and lung cancer, NTM have also been detected in breast tumors at levels higher than normal adjacent tissue. Evaluating the risks of continued ingestion of contaminated drinking water is paramount, especially given the ability of various bacteria to migrate from the gut to breast tissue via entero-mammary pathways. This underscores a pressing need to revise water safety monitoring guidelines and delve into hormonal factors, including addressing the disproportionate impact of NTM infections and breast cancer on women and examining the potential health risks posed by the cryptic and unchecked microbiota from drinking water.
Collapse
Affiliation(s)
- Ana Maranha
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Susana Alarico
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Daniela Nunes-Costa
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Melo-Marques
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| | - Inês Roxo
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
- Ph.D. Programme in Biomedicine and Experimental Biology (PDBEB), Institute for Interdisciplinary Research, University of Coimbra, 3004-504 Coimbra, Portugal
| | | | - Olga Caramelo
- Gynecology Department, Coimbra Hospital and University Centre (CHUC), 3004-561 Coimbra, Portugal;
| | - Nuno Empadinhas
- Center for Neuroscience and Cell Biology (CNC-UC), University of Coimbra, 3004-504 Coimbra, Portugal; (A.M.); (S.A.); (D.N.-C.); (I.M.-M.); (I.R.)
- Centre for Innovative Biomedicine & Biotechnology (CIBB), University of Coimbra, 3004-504 Coimbra, Portugal
| |
Collapse
|
6
|
LeChevallier MW, Prosser T, Stevens M. Opportunistic Pathogens in Drinking Water Distribution Systems-A Review. Microorganisms 2024; 12:916. [PMID: 38792751 PMCID: PMC11124194 DOI: 10.3390/microorganisms12050916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024] Open
Abstract
In contrast to "frank" pathogens, like Salmonella entrocolitica, Shigella dysenteriae, and Vibrio cholerae, that always have a probability of disease, "opportunistic" pathogens are organisms that cause an infectious disease in a host with a weakened immune system and rarely in a healthy host. Historically, drinking water treatment has focused on control of frank pathogens, particularly those from human or animal sources (like Giardia lamblia, Cryptosporidium parvum, or Hepatitis A virus), but in recent years outbreaks from drinking water have increasingly been due to opportunistic pathogens. Characteristics of opportunistic pathogens that make them problematic for water treatment include: (1) they are normally present in aquatic environments, (2) they grow in biofilms that protect the bacteria from disinfectants, and (3) under appropriate conditions in drinking water systems (e.g., warm water, stagnation, low disinfectant levels, etc.), these bacteria can amplify to levels that can pose a public health risk. The three most common opportunistic pathogens in drinking water systems are Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. This report focuses on these organisms to provide information on their public health risk, occurrence in drinking water systems, susceptibility to various disinfectants, and other operational practices (like flushing and cleaning of pipes and storage tanks). In addition, information is provided on a group of nine other opportunistic pathogens that are less commonly found in drinking water systems, including Aeromonas hydrophila, Klebsiella pneumoniae, Serratia marcescens, Burkholderia pseudomallei, Acinetobacter baumannii, Stenotrophomonas maltophilia, Arcobacter butzleri, and several free-living amoebae including Naegleria fowleri and species of Acanthamoeba. The public health risk for these microbes in drinking water is still unclear, but in most cases, efforts to manage Legionella, mycobacteria, and Pseudomonas risks will also be effective for these other opportunistic pathogens. The approach to managing opportunistic pathogens in drinking water supplies focuses on controlling the growth of these organisms. Many of these microbes are normal inhabitants in biofilms in water, so the attention is less on eliminating these organisms from entering the system and more on managing their occurrence and concentrations in the pipe network. With anticipated warming trends associated with climate change, the factors that drive the growth of opportunistic pathogens in drinking water systems will likely increase. It is important, therefore, to evaluate treatment barriers and management activities for control of opportunistic pathogen risks. Controls for primary treatment, particularly for turbidity management and disinfection, should be reviewed to ensure adequacy for opportunistic pathogen control. However, the major focus for the utility's opportunistic pathogen risk reduction plan is the management of biological activity and biofilms in the distribution system. Factors that influence the growth of microbes (primarily in biofilms) in the distribution system include, temperature, disinfectant type and concentration, nutrient levels (measured as AOC or BDOC), stagnation, flushing of pipes and cleaning of storage tank sediments, and corrosion control. Pressure management and distribution system integrity are also important to the microbial quality of water but are related more to the intrusion of contaminants into the distribution system rather than directly related to microbial growth. Summarizing the identified risk from drinking water, the availability and quality of disinfection data for treatment, and guidelines or standards for control showed that adequate information is best available for management of L. pneumophila. For L. pneumophila, the risk for this organism has been clearly established from drinking water, cases have increased worldwide, and it is one of the most identified causes of drinking water outbreaks. Water management best practices (e.g., maintenance of a disinfectant residual throughout the distribution system, flushing and cleaning of sediments in pipelines and storage tanks, among others) have been shown to be effective for control of L. pneumophila in water supplies. In addition, there are well documented management guidelines available for the control of the organism in drinking water distribution systems. By comparison, management of risks for Mycobacteria from water are less clear than for L. pneumophila. Treatment of M. avium is difficult due to its resistance to disinfection, the tendency to form clumps, and attachment to surfaces in biofilms. Additionally, there are no guidelines for management of M. avium in drinking water, and one risk assessment study suggested a low risk of infection. The role of tap water in the transmission of the other opportunistic pathogens is less clear and, in many cases, actions to manage L. pneumophila (e.g., maintenance of a disinfectant residual, flushing, cleaning of storage tanks, etc.) will also be beneficial in helping to manage these organisms as well.
Collapse
Affiliation(s)
| | - Toby Prosser
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| | - Melita Stevens
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| |
Collapse
|
7
|
Cazals M, Bédard E, Soucy C, Savard P, Prévost M. How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines. J Hosp Infect 2023; 141:9-16. [PMID: 37604277 DOI: 10.1016/j.jhin.2023.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 07/18/2023] [Accepted: 08/05/2023] [Indexed: 08/23/2023]
Abstract
BACKGROUND Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. AIM To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. METHODS Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. FINDINGS Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. CONCLUSION Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.
Collapse
Affiliation(s)
- M Cazals
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada.
| | - E Bédard
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada
| | - C Soucy
- Infection Prevention and Control, University of Montreal Hospital Centre (CHUM), Montreal, Canada
| | - P Savard
- Infection Prevention and Control, University of Montreal Hospital Centre (CHUM), Montreal, Canada; Department of Microbiology, Infectious Diseases and Immunology and University of Montreal Hospital Centre Research Centre (CRCHUM), University of Montreal, Canada
| | - M Prévost
- Civil, Geological and Mining Engineering Department, Polytechnique Montréal, Montreal, Canada
| |
Collapse
|
8
|
Ketelaars HAM, Wagenvoort AJ, Peters MCFM, Wunderer J, Hijnen WAM. Taxonomic diversity and biomass of the invertebrate fauna of nine drinking water treatment plants and their non-chlorinated distribution systems. WATER RESEARCH 2023; 242:120269. [PMID: 37393812 DOI: 10.1016/j.watres.2023.120269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 06/14/2023] [Accepted: 06/23/2023] [Indexed: 07/04/2023]
Abstract
Invertebrates such as Asellus aquaticus, halacarid mites, copepods and cladocerans are known to regularly occur in drinking water distribution systems (DWDS). An eight-year study investigated the biomass and taxonomic composition of invertebrates in the finished water of nine Dutch drinking water treatment plants (using surface water, ground water or dune-infiltrated water) and their non-chlorinated distribution systems. The main aims of the study were to examine the source waters' influence on invertebrate biomass and composition in the distribution networks and to describe invertebrate ecology in relation to the habitat of filters and the DWDS. Invertebrate biomass of the finished drinking waters of the surface water treatment plants was significantly higher than in the finished waters of the other treatment plants. This difference was due to the higher nutrient levels of the source water. The main part of the biomass in the finished water of the treatment plants consisted of rotifers, harpacticoid copepods, copepod larvae, cladocerans and oligochaetes, which are small-sized, euryoecious and tolerate broad environmental conditions. Most of them reproduce asexually. Most species found in the DWDS are known to be detritivores, but all are benthic and euryoecious organisms, many of which have a cosmopolitan distribution. The euryoeciousness of these freshwater species was also shown by their occurrence in brackish waters and ground or hyporheic waters and the ability of many eurythermic species to overwinter in the DWDS habitat. These species are preadapted to the oligotrophic environment of the DWDS and can develop stable populations there. Most species can reproduce asexually and the sexually reproducing invertebrates (Asellus aquaticus, cyclopoids and probably also halacarids) have obviously overcome the potential problem of finding a mating partner. This study also showed a significant correlation of DOC in the drinking water with the invertebrate biomass. A. aquaticus was the dominant biomass component in six out of nine locations and was highly correlated with the Aeromonas counts in the DWDS. Thus, invertebrate monitoring in DWDS is an important additional parameter in understanding biological stability conditions in non-chlorinated DWDS.
Collapse
Affiliation(s)
- Henk A M Ketelaars
- Evides Water Company, PO BOX 4472, Rotterdam, AL 3006, the Netherlands; Rubiconsult Water Quality Services, Vest 162, Dordrecht, TX 3311, the Netherlands.
| | | | | | - Julia Wunderer
- Evides Water Company, PO BOX 4472, Rotterdam, AL 3006, the Netherlands
| | - Wim A M Hijnen
- Evides Water Company, PO BOX 4472, Rotterdam, AL 3006, the Netherlands
| |
Collapse
|
9
|
Song JJX, Oguma K. Mycobacterial contamination in tap and shower waters in Thailand. Lett Appl Microbiol 2023; 76:ovad090. [PMID: 37528059 DOI: 10.1093/lambio/ovad090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/23/2023] [Accepted: 07/31/2023] [Indexed: 08/03/2023]
Abstract
Waterborne disease is increasingly becoming associated with opportunistic premise plumbing pathogens (OPPPs), which can resist residual chlorination, regrow throughout drinking water distribution systems, and colonize premise plumbing. Nontuberculous mycobacteria (NTM) include clinically important species and exert a high burden on healthcare systems. We briefly report a qPCR-based survey of Mycobacterium spp. numbers in tap, POU-treated, and shower waters from Bangkok, Thailand. Non-stagnant tap waters and non-stagnant shower waters had mean numbers of 1.3 × 103 and 2.4 × 103 copies/mL, respectively. Water stagnation resulted in mean numbers higher by up to 1.0 log. The lowest number, 25 copies/mL, was obtained from a POU-treated sample, while the highest number, 2.0 × 104 copies/mL, came from a stagnant tap. Comparing with international data, mean numbers in this study were greater than those in nine out of 11 (82%) comparable studies, and the maximum numbers in this study were also high. Our samples of Bangkok waters exhibited relatively high Mycobacterium spp. numbers, suggesting the need for appropriate POU treatment systems where NTM infection is a health concern. This survey data can be used to set inactivation performance targets in POU water disinfection system design and may also lead to quantitative microbial risk assessment (QMRA) studies.
Collapse
Affiliation(s)
- Jack Jia Xin Song
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| | - Kumiko Oguma
- Department of Urban Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8654, Japan
| |
Collapse
|
10
|
Wang M, Liu X, Qu L, Wang T, Zhu L, Feng J. Untangling microbiota diversity and assembly patterns in the world's longest underground culvert water diversion canal. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:981. [PMID: 37480396 DOI: 10.1007/s10661-023-11593-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Accepted: 07/10/2023] [Indexed: 07/24/2023]
Abstract
The long-distance underground box culvert water transport system (LUBWT) is a crucial link between the source of drinking water and the consumers. It must ensure the stability of water quality during transportation. However, uncontrollable microbial growth can develop in the water delivery system during the long delivery process, posing a risk to health and safety. Therefore, we applied 16 s and 18 s gene sequence analysis in order to study microbial communities in box culvert waters sampled in 2021, as well as a molecular ecological network-based approach to decipher microbial interactions and stability. Our findings revealed that, in contrast to natural freshwater ecosystems, micro-eukaryotes in LUBWT have complex interactions such as predation, parasitism, and symbiosis due to their semi-enclosed box culvert environment. Total nitrogen may be the primary factor affecting bacterial community interactions in addition to temperature. Moreover, employing stability indicators such as robustness and vulnerability, we also found that microbial stability varied significantly from season to season, with summer having the higher stability of microbial communities. Not only that but also the stability of the micronuclei also varied greatly during water transport, which might also be related to the complex interactions among the micro-eukaryotes. To summarize, our study reveals the microbial interactions and stability in LUBWT, providing essential ecological knowledge to ensure the safety of LUBWT's water quality.
Collapse
Affiliation(s)
- Mengyao Wang
- College of Environmental Science and Engineering, Nankai University, Tianjin, People's Republic of China
| | - Xinyong Liu
- Tianjin Branch of China South to North Water Diversion Middle Route Construction Management Bureau, Tianjin, People's Republic of China.
| | - Liang Qu
- Tianjin Branch of China South to North Water Diversion Middle Route Construction Management Bureau, Tianjin, People's Republic of China
| | - Tongtong Wang
- Tianjin Branch of China South to North Water Diversion Middle Route Construction Management Bureau, Tianjin, People's Republic of China
| | - Lin Zhu
- College of Environmental Science and Engineering, Nankai University, Tianjin, People's Republic of China
| | - Jianfeng Feng
- College of Environmental Science and Engineering, Nankai University, Tianjin, People's Republic of China.
| |
Collapse
|
11
|
van der Wielen PWJJ, Dignum M, Donocik A, Prest EI. Influence of Temperature on Growth of Four Different Opportunistic Pathogens in Drinking Water Biofilms. Microorganisms 2023; 11:1574. [PMID: 37375076 DOI: 10.3390/microorganisms11061574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/08/2023] [Accepted: 06/10/2023] [Indexed: 06/29/2023] Open
Abstract
High drinking water temperatures occur due to climate change and could enhance the growth of opportunistic pathogens in drinking water systems. We investigated the influence of drinking water temperatures on the growth of Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Mycobacterium kansasii and Aspergillus fumigatus in drinking water biofilms with an autochthonous microflora. Our results reveal that the growth of P. aeruginosa and S. maltophilia in the biofilm already occurred at 15.0 °C, whereas M. kansasii and A. fumigatus were able to grow when temperatures were above 20.0 °C and 25.0 °C, respectively. Moreover, the maximum growth yield of P. aeruginosa, M. kansasii and A. fumigatus increased with increasing temperatures up to 30 °C, whereas an effect of temperature on the yield of S. maltophilia could not be established. In contrast, the maximum ATP concentration of the biofilm decreased with increasing temperatures. We conclude from these results that high drinking water temperatures caused by, e.g., climate change can result in high numbers of P. aeruginosa, M. kansasii and A. fumigatus in drinking water systems, which poses a possible risk to public health. Consequently, it is recommended for countries with a more moderate climate to use or maintain a drinking water maximum standard temperature of 25 °C.
Collapse
Affiliation(s)
- Paul W J J van der Wielen
- KWR Water Research Institute, 3433 PE Nieuwegein, The Netherlands
- Laboratory of Microbiology, Wageningen University & Research, 6708 WE Wageningen, The Netherlands
| | | | | | | |
Collapse
|
12
|
van der Wielen PWJJ, Brouwer-Hanzens A, Italiaander R, Hijnen WAM. Initiating guidance values for novel biological stability parameters in drinking water to control regrowth in the distribution system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 871:161930. [PMID: 36740059 DOI: 10.1016/j.scitotenv.2023.161930] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/18/2023] [Accepted: 01/27/2023] [Indexed: 06/18/2023]
Abstract
Nine novel biological stability parameters for drinking water have been developed recently. Here, we report data for these nine parameters in treated water from 34 treatment plants in the Netherlands to deduce guidance values for these parameters. Most parameters did not show a strong correlation with another biological stability parameter in the same sample, demonstrating that most parameters hold different information on the biological stability of drinking water. Furthermore, the novel biological stability parameters in treated water varied considerably between plants and five parameters in treated water were significantly lower for drinking water produced from groundwater than surface water. The maximum biomass concentration (MBC7), cumulative biomass potential (CBP14) from the biomass production potential test (BPP-W) and the total organic carbon concentration in treated water from groundwater were predictive parameters for HPC22 and Aeromonas regrowth in the distribution system. Guidance values of 8.6 ng ATP L-1, 110 d·ng ATP L-1 and 4.1 mg C L-1 were deduced for these parameters, under which the HPC22 and Aeromonas numbers remain at regulatory level. The maximum biomass growth (MBG7) from the BPP-W test, the particulate and/or high molecular organic carbon and the iron accumulation rate in treated water from surface water were predictive parameters for HPC22 and Aeromonas regrowth in the distribution system. Deduced guidance values for these biological stability parameters were 4.5 ng ATP L-1, 47 μg C L-1 and 0.34 mg Fe m-2 day-1, respectively. We conclude from our study that a multiple parameter assessment is required to reliable describe the biological stability of drinking water, that the biological stability of drinking water produced from groundwater is described with other parameters than the biological stability of drinking water produced from surface water, and that guidance values for predictive biological stability parameters were inferred under which HPC22 and Aeromonas regrowth is under control.
Collapse
Affiliation(s)
- Paul W J J van der Wielen
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708WE Wageningen, the Netherlands.
| | - Anke Brouwer-Hanzens
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands
| | - Ronald Italiaander
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands
| | - Wim A M Hijnen
- Evides Water Company, PO Box 4472, 3006AL Rotterdam, the Netherlands
| |
Collapse
|
13
|
Zhao HX, Zhang TY, Wang H, Hu CY, Tang YL, Xu B. Occurrence of fungal spores in drinking water: A review of pathogenicity, odor, chlorine resistance and control strategies. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 853:158626. [PMID: 36087680 DOI: 10.1016/j.scitotenv.2022.158626] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/17/2022] [Accepted: 09/05/2022] [Indexed: 06/15/2023]
Abstract
Fungi in drinking water have been long neglected due to the lack of convenient analysis methods, widely accepted regulations and efficient control strategies. However, in the last few decades, fungi in drinking water have been widely recognized as opportunity pathogens that cause serious damage to the health of immune-compromised individuals. In drinking water treatment plants, fungal spores are more resistant to chlorine disinfection than bacteria and viruses, which can regrow in drinking water distribution systems and subsequently pose health threats to water consumers. In addition, fungi in drinking water may represent an ignored source of taste and odor (T&O). This review identified 74 genera of fungi isolated from drinking water and presented their detailed taxonomy, sources and biomass levels in drinking water systems. The typical pathways of exposure of water-borne fungi and the main effects on human health are clarified. The fungi producing T&O compounds and their products are summarized. Data on free chlorine or monochloramine inactivation of fungal spores and other pathogens are compared. At the first time, we suggested four chlorine-resistant mechanisms including aggregation to tolerate chlorine, strong cell walls, cellular responses to oxidative stress and antioxidation of melanin, which are instructive for the future fungi control attempts. Finally, the inactivation performance of fungal spores by various technologies are comprehensively analyzed. The purpose of this study is to provide an overview of fungi distribution and risks in drinking water, provide insight into the chlorine resistance mechanisms of fungal spores and propose approaches for the control of fungi in drinking water.
Collapse
Affiliation(s)
- Heng-Xuan Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Tian-Yang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Chen-Yan Hu
- College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, PR China
| | - Yu-Lin Tang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Bin Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Yangtze Water Environment, Ministry of Education, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
14
|
Moghaddam S, Nojoomi F, Dabbagh Moghaddam A, Mohammadimehr M, Sakhaee F, Masoumi M, Siadat SD, Fateh A. Isolation of nontuberculous mycobacteria species from different water sources: a study of six hospitals in Tehran, Iran. BMC Microbiol 2022; 22:261. [PMID: 36309645 DOI: 10.1186/s12866-022-02674-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 10/20/2022] [Indexed: 11/10/2022] Open
Abstract
Abstract
Purpose
Nontuberculous mycobacteria (NTM) are ubiquitous bacteria that are naturally resistant to disinfectants and antibiotics and can colonize systems for supplying drinking water. Therefore, this study aimed to evaluate the prevalence of NTM in the drinking water of six hospitals in Tehran, Iran.
Methods
Totally, 198 water samples were collected. Each water sample was filtered via a membrane filter with a pore size of 0.45 µm and then decontaminated by 0.005% cetylpyridinium chloride. The membrane filters were incubated on two Lowenstein-Jensen media at 25 °C and 37 °C for 8 weeks. The positive cultures were identified with phenotypic tests, and then NTM species were detected according to the hsp65, rpoB, and 16S rDNA genes. Drug susceptibility testing (DST) was also carried out.
Results
Overall, 76 (40.4%) of the isolates were slowly growing mycobacteria (SGM) and 112 (59.6%) of the ones were rapidly growing mycobacteria (RGM). The most common NTM were Mycobacterium aurum, M. gordonae, M. phocaicum, M. mucogenicum, M. kansasii, M. simiae, M. gadium, M. lentiflavum, M. fortuitum, and M. porcinum. Among these 188 samples, NTM ranged from 1 to > 300 colony-forming unit (CFU) /500 mL, with a median of 182 CFU/500 mL. In the infectious department of all hospitals, the amount of CFU was higher than in other parts of the hospitals. The DST findings in this study indicated the diversity of resistance to different drugs. Among RGM, M. mucogenicum was the most susceptible isolate; however, M. fortuitum showed a different resistance pattern. Also, among SGM isolates, M. kansasii and M. simiae, the diversity of DST indicated.
Conclusions
The current study showed NTM strains could be an important component of hospital water supplies and a possible source of nosocomial infections according to the CFU reported in this study. The obtained findings also help clarify the dynamics of NTM variety and distribution in the water systems of hospitals in the research area.
Collapse
|
15
|
Learbuch KLG, Smidt H, van der Wielen PWJJ. Water and biofilm in drinking water distribution systems in the Netherlands. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 831:154940. [PMID: 35367266 DOI: 10.1016/j.scitotenv.2022.154940] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 03/26/2022] [Accepted: 03/27/2022] [Indexed: 06/14/2023]
Abstract
To keep the high quality of drinking water in the future for non-chlorinated drinking water systems, knowledge about the variables that most strongly affect this quality is necessary in order to know where to focus on and possibly even change aspects of drinking water production and distribution. Therefore, the aim of this study was to investigate which variables (source of drinking water, growth potential and pipe material type) have the biggest influence on bacterial community composition and biomass concentration of drinking water and biofilm in distribution systems. Ten different distribution systems were sampled for water and biofilm, obtained from four different pipe materials, throughout the Netherlands. The distribution systems are supplied either with drinking water produced from groundwater or surface water, and differ in drinking water quality parameters such as the growth potential. We found a significant relationship for growth potential and ATP concentration in water, but for the ATP in the biofilm none of the parameters showed a significant effect. Furthermore, the source of the drinking water and the pipe material did not significantly affect the ATP concentration in water and biofilm. The bacterial composition of in both water and biofilm was significantly different between distribution systems delivering water with low and high growth potential and between drinking water produced from groundwater or surface water. In contrast, the different pipe materials did not significantly affect composition of biofilm-associated communities. We conclude from these results that the growth potential of the treated water best explains the variation in biomass and bacterial composition in water and biofilm of non-chlorinated drinking water distribution systems followed by the drinking water source, whereas pipe materials seem to be of lesser importance.
Collapse
Affiliation(s)
- K L G Learbuch
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands
| | - H Smidt
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708WE Wageningen, the Netherlands
| | - P W J J van der Wielen
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708WE Wageningen, the Netherlands.
| |
Collapse
|
16
|
Monitoring Bacterial Community Dynamics in a Drinking Water Treatment Plant: An Integrative Approach Using Metabarcoding and Microbial Indicators in Large Water Volumes. WATER 2022. [DOI: 10.3390/w14091435] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Monitoring bacterial communities in a drinking water treatment plant (DWTP) may help to understand their regular operations. Bacterial community dynamics in an advanced full-scale DWTP were analyzed by 16S rRNA metabarcoding, and microbial water quality indicators were determined at nine different stages of potabilization: river water and groundwater intake, decantation, sand filtration, ozonization, carbon filtration, reverse osmosis, mixing chamber and post-chlorination drinking water. The microbial content of large water volumes (up to 1100 L) was concentrated by hollow fiber ultrafiltration. Around 10 million reads were obtained and grouped into 10,039 amplicon sequence variants. Metabarcoding analysis showed high bacterial diversity at all treatment stages and above all in groundwater intake, followed by carbon filtration and mixing chamber samples. Shifts in bacterial communities occurred downstream of ozonization, carbon filtration, and, more drastically, chlorination. Proteobacteria and Bacteroidota predominated in river water and throughout the process, but in the final drinking water, the strong selective pressure of chlorination reduced diversity and was clearly dominated by Cyanobacteria. Significant seasonal variation in species distribution was observed in decantation and carbon filtration samples. Some amplicon sequence variants related to potentially pathogenic genera were found in the DWTP. However, they were either not detected in the final water or in very low abundance (<2%), and all EU Directive quality standards were fully met. A combination of culture and high-throughput sequencing techniques may help DWTP managers to detect shifts in microbiome, allowing for a more in-depth assessment of operational performance.
Collapse
|
17
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
18
|
Hu D, Hong H, Rong B, Wei Y, Zeng J, Zhu J, Bai L, Guo F, Yu X. A comprehensive investigation of the microbial risk of secondary water supply systems in residential neighborhoods in a large city. WATER RESEARCH 2021; 205:117690. [PMID: 34614460 DOI: 10.1016/j.watres.2021.117690] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 09/15/2021] [Accepted: 09/19/2021] [Indexed: 06/13/2023]
Abstract
Secondary water supply systems (SWSSs) are characterized by long water stagnation and low levels of chlorine residuals, which may pose a high microbial risk to terminal users. In this study, the SWSSs of 12 residential neighborhoods in a metropolitan area of 5 million people in southeastern China were seasonally investigated to assess their microbial risks by determining more than 30 physicochemical and biological parameters. Although the microbiological quality of SWSS water met the requirements of the standards for drinking water quality of China, it did deteriorate in various aspects. The heterotrophic plate counts with R2A media were high (> 100 CFU/mL) in some SWSS tank and tap water samples. Propidium monoazide (PMA)-qPCR revealed a one magnitude higher abundance of viable bacteria in the tank and tap water samples (average 103.63±1.10 and 103.65±1.25 gene copies/mL, respectively) compared with the input water samples, and Enterococcus, Acanthamoeba, and Hartmannella vermiformis were only detected in the tanks. In particular, the high detection frequency of Legionella in 35% tank and 21% tap water samples suggested it is a supplementary microbial safety indicator in SWSSs. The microbial regrowth potential was more obvious in summer, and Illumina sequencing also demonstrated distinct seasonal changes in the relative abundance of bacterial gene sequences at the genus level. Turbidity and residual chlorine were closely connected with total bacterial biomass, and the latter seemed responsible for microbial community structure alteration. The extremely low chlorine residuals associated with a high abundance of total bacteria (as high as 106.48 gene copies/mL) and Legionella (as high as 106.71 gene copies/100 mL) in the closed valve tanks highlighted the high microbial risk increased by mishandling the operation of SWSSs. This study found that SWSSs possessed a higher microbial risk than the drinking water network, which suggested that the frequency and scope of monitoring the microbial risk of SWSSs in megacities should be strengthened for the purpose of waterborne epidemic disease prevention and control.
Collapse
Affiliation(s)
- Dong Hu
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Huarong Hong
- Xiamen Center for Disease Control and Prevention, Xiamen 361021, China
| | - Biao Rong
- Xiamen Center for Disease Control and Prevention, Xiamen 361021, China
| | - Yating Wei
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Jie Zeng
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China
| | - Jun Zhu
- School of Life Sciences, Xiamen University, Xiamen 361102, China
| | - Lijun Bai
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China
| | - Feng Guo
- School of Life Sciences, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment & Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
19
|
Zhang C, Struewing I, Mistry JH, Wahman DG, Pressman J, Lu J. Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems. WATER RESEARCH 2021; 205:117571. [PMID: 34628111 PMCID: PMC8629321 DOI: 10.1016/j.watres.2021.117571] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/02/2021] [Accepted: 08/13/2021] [Indexed: 05/06/2023]
Abstract
Water-based opportunistic pathogens (OPs) are a leading cause of drinking-water-related disease outbreaks, especially in developed countries such as the United States (US). Physicochemical water quality parameters, especially disinfectant residuals, control the (re)growth, presence, colonization, and concentrations of OPs in drinking water distribution systems (DWDSs), while the relationship between OPs and those parameters remain unclear. This study aimed to quantify how physicochemical parameters, mainly monochloramine residual concentration, hydraulic residence time (HRT), and seasonality, affected the occurrence and concentrations of four common OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in four full-scale DWDSs in the US. Legionella as a dominant OP occurred in 93.8% of the 64 sampling events and had a mean density of 4.27 × 105 genome copies per liter. Legionella positively correlated with Mycobacterium, Pseudomonas, and total bacteria. Multiple regression with data from the four DWDSs showed that Legionella had significant correlations with total chlorine residual level, free ammonia concentration, and trihalomethane concentration. Therefore, Legionella is a promising indicator of water-based OPs, reflecting microbial water quality in chloraminated DWDSs. The OP concentrations had strong seasonal variations and peaked in winter and/or spring possibly because of reduced water usage (i.e., increased water stagnation or HRT) during cold seasons. The OP concentrations generally increased with HRT presumably because of disinfectant residual decay, indicating the importance of well-maintaining disinfectant residuals in DWDSs for OP control. The concentrations of Mycobacterium, Pseudomonas, and V. vermiformis were significantly associated with total chlorine residual concentration, free ammonia concentration, and pH and trihalomethane concentration, respectively. Overall, this study demonstrates how the significant spatiotemporal variations of OP concentrations in chloraminated DWDSs correlated with critical physicochemical water quality parameters such as disinfectant residual levels. This work also indicates that Legionella is a promising indicator of OPs and microbial water quality in chloraminated DWDSs.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, Ohio, USA
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, Texas, USA
| | - David G Wahman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jonathan Pressman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA.
| |
Collapse
|
20
|
Wen G, Tan L, Cao R, Wan Q, Xu X, Wu G, Wang J, Huang T. Inactivation of waterborne fungal spores by 1-bromo-3-chloro-5,5-dimethylhydantoin: Kinetics, influencing factors and mechanisms. CHEMOSPHERE 2021; 274:129764. [PMID: 33545590 DOI: 10.1016/j.chemosphere.2021.129764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 01/19/2021] [Accepted: 01/21/2021] [Indexed: 06/12/2023]
Abstract
Fungal contamination in drinking water source has become a problem worth studying, as waterborne fungi may cause deterioration of water quality and outbreak of diseases. Various disinfection methods have been explored to control fungal spores in drinking water, such as chlor(am)ination, ozonation, chlorine dioxide treatment, but these methods are not appropriate for remote areas, owing to the difficulties in preparation, carriage and storage. In this study, a powdery disinfectant of 1-bromo-3-chloro-5,5-dimethylhydantoin (BCDMH), which facilitated transportation and preservation, was firstly chosen to inactivate opportunistic pathogens of Aspergillus niger (A. niger) and Penicillium polonicum (P. polonicum). The results revealed that the inactivation kinetics of fungal spores by BCDMH fitted to Chick-Watson model well, with the inactivation rate constant of 0.011 and 0.034 L mg-1 min-1 for A. niger and P. polonicum, respectively. Acidic condition and high temperature promoted the inactivation by BCDMH. Compared with chlorine, BCDMH showed relative weaker ability on inactivation of fungal spores. However, it was demonstrated that the inactivation efficiency of BCDMH was obviously enhanced by adding halide ions, with 11 or 36 folds for A. niger and 4 or 15 folds for P. polonicum by adding 40 μM Br- or I-. The inactivation mechanisms were detected by flow cytometry and scanning electron microscope. Fungal spores lost their culturability firstly, then membrane integrity was damaged. Meanwhile, the esterase activity and intracellular reactive oxygen species level changed, and finally intracellular adenosine triphosphate released.
Collapse
Affiliation(s)
- Gang Wen
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China.
| | - Lili Tan
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Ruihua Cao
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Qiqi Wan
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Xiangqian Xu
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Gehui Wu
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Jingyi Wang
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| | - Tinglin Huang
- Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, PR China
| |
Collapse
|
21
|
Calero Preciado C, Boxall J, Soria-Carrasco V, Martínez S, Douterelo I. Implications of Climate Change: How Does Increased Water Temperature Influence Biofilm and Water Quality of Chlorinated Drinking Water Distribution Systems? Front Microbiol 2021; 12:658927. [PMID: 34168627 PMCID: PMC8217620 DOI: 10.3389/fmicb.2021.658927] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Accepted: 05/04/2021] [Indexed: 01/04/2023] Open
Abstract
Temperature variation can promote physico-chemical and microbial changes in the water transported through distribution systems and influence the dynamics of biofilms attached to pipes, thus contributing to the release of pathogens into the bulk drinking water. An experimental real-scale chlorinated DWDS was used to study the effect of increasing temperature from 16 to 24°C on specific pathogens, bacterial-fungal communities (biofilm and water samples) and determine the risk of material accumulation and mobilisation from the pipes into the bulk water. Biofilm was developed for 30 days at both temperatures in the pipe walls, and after this growth phase, a flushing was performed applying 4 gradual steps by increasing the shear stress. The fungal-bacterial community characterised by Illumina MiSeq sequencing, and specific pathogens were studied using qPCR: Mycobacterium spp., Mycobacterium avium complex, Acanthamoeba spp., Pseudomonas aeruginosa, Legionella pneumophilia, and Stenotrophomonas maltophilia. Sequencing data showed that temperature variation significantly modified the structure of biofilm microbial communities from the early stages of biofilm development. Regarding bacteria, Pseudomonas increased its relative abundance in biofilms developed at 24°C, while fungal communities showed loss of diversity and richness, and the increase in dominance of Fusarium genus. After the mobilisation phase, Pseudomonas continued being the most abundant genus at 24°C, followed by Sphingobium and Sphingomonas. For biofilm fungal communities after the mobilisation phase, Helotiales incertae sedis and Fusarium were the most abundant taxa. Results from qPCR showed a higher relative abundance of Mycobacterium spp. on day 30 and M. avium complex throughout the growth phase within the biofilms at higher temperatures. The temperature impacts were not only microbial, with physical mobilisation showing higher discolouration response and metals release due to the increased temperature. While material accumulation was accelerated by temperature, it was not preferentially to either stronger or weaker biofilm layers, as turbidity results during the flushing steps showed. This research yields new understanding on microbial challenges that chlorinated DWDS will undergo as global temperature rises, this information is needed in order to protect drinking water quality and safety while travelling through distribution systems.
Collapse
Affiliation(s)
- Carolina Calero Preciado
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom.,NERC Biomolecular Analysis Facility, Department of Animal and Plant Sciences, The University of Sheffield, Sheffield, United Kingdom
| | - Joby Boxall
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| | - Víctor Soria-Carrasco
- Department of Animal and Plant Sciences, The University of Sheffield, Sheffield, United Kingdom
| | - Soledad Martínez
- Área de Microbiología, Departamento de Biociencias, Facultad de Química, Universidad de la República, Montevideo, Uruguay
| | - Isabel Douterelo
- Department of Civil and Structural Engineering, Sheffield Water Centre, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
22
|
Zoccola R, Di Blasio A, Bossotto T, Pontei A, Angelillo M, Dondo A, Goria M, Zoppi S. Validation of a Novel Diagnostic Approach Combining the VersaTREK™ System for Recovery and Real-Time PCR for the Identification of Mycobacterium chimaera in Water Samples. Microorganisms 2021; 9:microorganisms9051031. [PMID: 34064701 PMCID: PMC8150998 DOI: 10.3390/microorganisms9051031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 05/03/2021] [Accepted: 05/09/2021] [Indexed: 11/16/2022] Open
Abstract
Mycobacterium chimaera is an emerging pathogen associated with endocarditis and vasculitis following cardiac surgery. Although it can take up to 6-8 weeks to culture on selective solid media, culture-based detection remains the gold standard for diagnosis, so more rapid methods are urgently needed. For the present study, we processed environmental M. chimaera infected simulates at volumes defined in international guidelines. Each preparation underwent real-time PCR; inoculates were placed in a VersaTREK™ automated microbial detection system and onto selective Middlebrook 7H11 agar plates. The validation tests showed that real-time PCR detected DNA up to a concentration of 10 ng/µL. A comparison of the isolation tests showed that the PCR method detected DNA in a dilution of ×102 CFU/mL in the bacterial suspensions, whereas the limit of detection in the VersaTREK™ was <10 CFU/mL. Within less than 3 days, the VersaTREK™ detected an initial bacterial load of 100 CFU. The detection limit did not seem to be influenced by NaOH decontamination or the initial water sample volume; analytical sensitivity was 1.5 × 102 CFU/mL; positivity was determined in under 15 days. VersaTREK™ can expedite mycobacterial growth in a culture. When combined with PCR, it can increase the overall recovery of mycobacteria in environmental samples, making it potentially applicable for microbial control in the hospital setting and also in environments with low levels of contamination by viable mycobacteria.
Collapse
Affiliation(s)
- Roberto Zoccola
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Alessia Di Blasio
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
- Azienda Sanitaria Locale TO3 S.C. Sanità Animale, Pinerolo, 10064 Torino, Italy
- Correspondence: ; Tel.: +39-0121-235489
| | - Tiziana Bossotto
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Angela Pontei
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Maria Angelillo
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Alessandro Dondo
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Maria Goria
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| | - Simona Zoppi
- Istituto Zooprofilattico Sperimentale del Piemonte, Liguria e Valle d’Aosta, 10154 Torino, Italy; (R.Z.); (T.B.); (A.P.); (M.A.); (A.D.); (M.G.); (S.Z.)
| |
Collapse
|
23
|
Learbuch KLG, Smidt H, van der Wielen PWJJ. Influence of pipe materials on the microbial community in unchlorinated drinking water and biofilm. WATER RESEARCH 2021; 194:116922. [PMID: 33640751 DOI: 10.1016/j.watres.2021.116922] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 02/08/2021] [Accepted: 02/09/2021] [Indexed: 06/12/2023]
Abstract
Biodegradable compounds can cause undesired microbial growth in drinking water systems and these compounds can originate from the water or pipe materials used in drinking water systems. The aim of our study was to determine the influence of different pipe materials on the microbial populations in water and biofilm under semi-stagnant conditions. The microbial communities in biofilm and water, which were in contact with seven different materials, were characterized by determining ATP concentrations, microbial composition gene copy numbers of some specific microbial groups. The ATP concentration in water and biofilm varied between the different materials with glass (negative control) < copper < PVCC < PE-Xc < PE-Xb < PE-100 < PVC-P. Gene copy numbers of Legionella spp., Mycobacterium spp., Pseudomonas spp., Aeromonas spp., fungi and Vermamoeba vermiformis were also higher for PVC-P and PE than for glass, copper and PVCC. The bacterial community composition in water and biofilm varied between materials as well. PERMANOVA and CAP analysis demonstrated that copper and PVC-P are different when compared to the other materials. Furthermore, bacterial community composition and ATP concentrations in water and biofilm were similar after eight and 16 weeks incubation, but differed from results obtained after one week. Finally, the ATP, the specific microbial groups and the bacterial community composition also differed between water and biofilm on each material. We conclude from our study that pipe material is an important factor that influences the biomass concentration, abundance of specific microorganisms and the bacterial community composition in distribution systems with unchlorinated drinking water.
Collapse
Affiliation(s)
- K L G Learbuch
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands; Wetsus, Oostergoweg 9, 8911 MA Leeuwarden, the Netherlands.
| | - H Smidt
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4 6708WE Wageningen, the Netherlands
| | - P W J J van der Wielen
- KWR Water Research Institute, Groningenhaven 7, 3433PE Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4 6708WE Wageningen, the Netherlands
| |
Collapse
|
24
|
Fu Y, Peng H, Liu J, Nguyen TH, Hashmi MZ, Shen C. Occurrence and quantification of culturable and viable but non-culturable (VBNC) pathogens in biofilm on different pipes from a metropolitan drinking water distribution system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 764:142851. [PMID: 33097267 DOI: 10.1016/j.scitotenv.2020.142851] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 10/01/2020] [Accepted: 10/02/2020] [Indexed: 06/11/2023]
Abstract
Waterborne pathogens have been found in biofilms grown in drinking water distribution system (DWDS). However, there is a lack of quantitative study on the culturability of pathogens in biofilms from metropolitan DWDS. In this study, we quantified culturable and viable but non-culturable (VBNC) Escherichia coli, Salmonella enterica, Pseudomonas aeruginosa and Vibrio cholerae in biofilms collected from five kinds of pipes (galvanized steel pipe, steel pipe, stainless steel clad pipe, ductile cast iron pipe and polyethylene pipe) and associated drinking water at an actual chlorinated DWDS in use from China. The results of these comprehensive analyses revealed that pipe material is a significant factor influencing the culturability of pathogen and microbial communities. Network analysis of the culturable pathogens and 16S rRNA gene inferred potential interactions between microbiome and culturability of pathogens. Although the water quality met the Chinese national standard of drinking water, however, VBNC pathogens were detected in both biofilms and water from the DWDS. This investigation suggests that stainless steel clad pipe (SSCP) was a better choice for pathogen control compared with other metal pipes. To our knowledge, this is the first study on culturable and VBNC pathogens in biofilms of different pipe materials in metropolitan DWDS.
Collapse
Affiliation(s)
- Yulong Fu
- Department of Environmental Engineering, Zhejiang University, Hangzhou 310058, China
| | - Hongxi Peng
- Department of Civil Engineering, Zhejiang University, Hangzhou 310058, China
| | - Jingqing Liu
- Department of Civil Engineering, Zhejiang University, Hangzhou 310058, China
| | - Thanh H Nguyen
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, United States
| | | | - Chaofeng Shen
- Department of Environmental Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
25
|
Saxena S, Spaink HP, Forn-Cuní G. Drug Resistance in Nontuberculous Mycobacteria: Mechanisms and Models. BIOLOGY 2021; 10:biology10020096. [PMID: 33573039 PMCID: PMC7911849 DOI: 10.3390/biology10020096] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 01/25/2021] [Accepted: 01/26/2021] [Indexed: 02/07/2023]
Abstract
The genus Mycobacteria comprises a multitude of species known to cause serious disease in humans, including Mycobacterium tuberculosis and M. leprae, the responsible agents for tuberculosis and leprosy, respectively. In addition, there is a worldwide spike in the number of infections caused by a mixed group of species such as the M. avium, M. abscessus and M. ulcerans complexes, collectively called nontuberculous mycobacteria (NTMs). The situation is forecasted to worsen because, like tuberculosis, NTMs either naturally possess or are developing high resistance against conventional antibiotics. It is, therefore, important to implement and develop models that allow us to effectively examine the fundamental questions of NTM virulence, as well as to apply them for the discovery of new and improved therapies. This literature review will focus on the known molecular mechanisms behind drug resistance in NTM and the current models that may be used to test new effective antimicrobial therapies.
Collapse
|
26
|
Kasuga I, Suzuki M, Kurisu F, Furumai H. Molecular-level characterization of biodegradable organic matter causing microbial regrowth in drinking water by non-target screening using Orbitrap mass spectrometry. WATER RESEARCH 2020; 184:116130. [PMID: 32731039 DOI: 10.1016/j.watres.2020.116130] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 06/14/2020] [Accepted: 06/28/2020] [Indexed: 06/11/2023]
Affiliation(s)
- Ikuro Kasuga
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan.
| | - Miyu Suzuki
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Futoshi Kurisu
- Research Center for Water Environment Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| |
Collapse
|
27
|
Martin RL, Harrison K, Proctor CR, Martin A, Williams K, Pruden A, Edwards MA. Chlorine Disinfection of Legionella spp., L. pneumophila, and Acanthamoeba under Warm Water Premise Plumbing Conditions. Microorganisms 2020; 8:E1452. [PMID: 32971988 PMCID: PMC7563980 DOI: 10.3390/microorganisms8091452] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Revised: 09/16/2020] [Accepted: 09/19/2020] [Indexed: 11/30/2022] Open
Abstract
Premise plumbing conditions can contribute to low chlorine or chloramine disinfectant residuals and reactions that encourage opportunistic pathogen growth and create risk of Legionnaires' Disease outbreaks. This bench-scale study investigated the growth of Legionella spp. and Acanthamoeba in direct contact with premise plumbing materials-glass-only control, cross-linked polyethylene (PEX) pipe, magnesium anode rods, iron pipe, iron oxide, pH 10, or a combination of factors. Simulated glass water heaters (SGWHs) were colonized by Legionella pneumophila and exposed to a sequence of 0, 0.1, 0.25, and 0.5 mg/L chlorine or chloramine, at two levels of total organic carbon (TOC), over 8 weeks. Legionella pneumophila thrived in the presence of the magnesium anode by itself and or combination with other factors. In most cases, 0.5 mg/L Cl2 caused a significant rapid reduction of L. pneumophila, Legionella spp., or total bacteria (16S rRNA) gene copy numbers, but at higher TOC (>1.0 mg C/L), a chlorine residual of 0.5 mg/L Cl2 was not effective. Notably, Acanthamoeba was not significantly reduced by the 0.5 mg/L chlorine dose.
Collapse
Affiliation(s)
- Rebekah L. Martin
- Department of Civil and Environmental Engineering, Virginia Military Institute, Lexington, VA 24450, USA;
| | - Kara Harrison
- Internal Medicine Residency Program, University of Virginia, Charlottesville, VA 22904, USA;
| | - Caitlin R. Proctor
- Department of Environmental and Ecological Engineering, Department of Civil Engineering, Department of Materials Engineering, Department of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA;
| | - Amanda Martin
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24450, USA; (A.M.); (K.W.); (A.P.)
| | - Krista Williams
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24450, USA; (A.M.); (K.W.); (A.P.)
| | - Amy Pruden
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24450, USA; (A.M.); (K.W.); (A.P.)
| | - Marc A. Edwards
- Charles E. Via, Jr. Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24450, USA; (A.M.); (K.W.); (A.P.)
| |
Collapse
|
28
|
Zhou X, Ahmad JI, van der Hoek JP, Zhang K. Thermal energy recovery from chlorinated drinking water distribution systems: Effect on chlorine and microbial water and biofilm characteristics. ENVIRONMENTAL RESEARCH 2020; 187:109655. [PMID: 32450425 DOI: 10.1016/j.envres.2020.109655] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 04/09/2020] [Accepted: 05/08/2020] [Indexed: 06/11/2023]
Abstract
Thermal energy recovery from drinking water has a high potential in the application of sustainable building and industrial cooling. However, drinking water and biofilm microbial qualities should be concerned because the elevated water temperature after cold recovery may influence the microbial activities in water and biofilm phases in drinking water distribution systems (DWDSs). In this study, the effect of cold recovery on microbial qualities was investigated in a chlorinated DWDS. The chlorine decay was slight (1.1%-15.5%) due to a short contact time (~60 s) and was not affected by the cold recovery (p > 0.05). The concentrations of cellular ATP and intact cell numbers in the bulk water were partially inactivated by the residual chlorine, with the removal rates of 10.1%-16.2% and 22.4%-29.4%, respectively. The chlorine inactivation was probably promoted by heat exchangers but was not further enhanced by higher temperatures. The higher water temperature (25 °C) enhanced the growth of biofilm biomass on pipelines. Principle coordination analysis (PCoA) showed that the biofilms on the stainless steel plates of HEs and the plastic pipe inner surfaces had totally different community compositions. Elevated temperatures favored the growth of Pseudomonas spp. and Legionella spp. in the biofilm after cold recovery. The community functional predictions revealed more abundances of five human diseases (e.g. Staphylococcis aureus infection) and beta-lactam resistance pathways in the biofilms at higher temperature. Compared with a previous study with a non-chlorinated DWDS, chlorine dramatically reduced the biofilm biomass growth but raised the relative abundances of the chlorine-resistant genera (i.e. Pseudomonas and Sphingomonas) in bacterial communities.
Collapse
Affiliation(s)
- Xinyan Zhou
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, Zhejiang, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands
| | - Jawairia Imtiaz Ahmad
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Institute of Environmental Sciences and Engineering, School of Civil and Environmental Engineering, National University of Science and Technology, H-12 Sector, Islamabad, Pakistan
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Waternet, Korte Ouderkerkerdijk 7, 1096 AC, Amsterdam, the Netherlands
| | - Kejia Zhang
- College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, 310058, Zhejiang, China.
| |
Collapse
|
29
|
Drinking Water Temperature around the Globe: Understanding, Policies, Challenges and Opportunities. WATER 2020. [DOI: 10.3390/w12041049] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Water temperature is often monitored at water sources and treatment works; however, there is limited monitoring of the water temperature in the drinking water distribution system (DWDS), despite a known impact on physical, chemical and microbial reactions which impact water quality. A key parameter influencing drinking water temperature is soil temperature, which is influenced by the urban heat island effects. This paper provides critique and comprehensive summary of the current knowledge, policies and challenges regarding drinking water temperature research and presents the findings from a survey of international stakeholders. Knowledge gaps as well as challenges and opportunities for monitoring and research are identified. The conclusion of the study is that temperature in the DWDS is an emerging concern in various countries regardless of the water source and treatment, climate conditions, or network characteristics such as topology, pipe material or diameter. More research is needed, especially to determine (i) the effect of higher temperatures, (ii) a legislative limit on temperature and (iii) measures to comply with this limit.
Collapse
|
30
|
Ahmad JI, Liu G, van der Wielen PWJJ, Medema G, Peter van der Hoek J. Effects of cold recovery technology on the microbial drinking water quality in unchlorinated distribution systems. ENVIRONMENTAL RESEARCH 2020; 183:109175. [PMID: 31999996 DOI: 10.1016/j.envres.2020.109175] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 01/22/2020] [Accepted: 01/22/2020] [Indexed: 06/10/2023]
Abstract
Drinking water distribution systems (DWDSs) are used to supply hygienically safe and biologically stable water for human consumption. The potential of thermal energy recovery from drinking water has been explored recently to provide cooling for buildings. Yet, the effects of increased water temperature induced by this "cold recovery" on the water quality in DWDSs are not known. The objective of this study was to investigate the impact of cold recovery from DWDSs on the microbiological quality of drinking water. For this purpose, three pilot distribution systems were operated in parallel for 38 weeks. System 1 has an operational heat exchanger, mimicking the cold recovery system by maintaining the water temperature at 25 °C; system 2 operated with a non-operational heat exchanger and system 3 run without heat exchanger. The results showed no significant effects on drinking water quality: cell numbers and ATP concentrations remained around 3.5 × 105 cells/ml and 4 ng ATP/l, comparable observed operational taxonomic units (OTUs) (~470-490) and similar Shannon indices (7.7-8.9). In the system with cold recovery, a higher relative abundance of Pseudomonas spp. and Chryseobacterium spp. was observed in the drinking water microbial community, but only when the cold recovery induced temperature difference (ΔT) was higher than 9 °C. In the 38 weeks' old biofilm, higher ATP concentration (475 vs. 89 pg/cm2), lower diversity (observed OTUs: 88 vs. ≥200) and a different bacterial community composition (e.g. higher relative abundance of Novosphingobium spp.) were detected, which did not influence water quality. No impacts were observed for the selected opportunisitic pathogens after introducing cold recovery. It is concluded that cold recovery does not affect bacterial water quality. Further investigation for a longer period is commended to understand the dynamic responses of biofilm to the increased temperature caused by cold recovery.
Collapse
Affiliation(s)
- Jawairia Imtiaz Ahmad
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Institute of Environmental Sciences and Engineering, School of Civil and Environmental Engineering, National University of Science and Technology, H-12 Sector, Islamabad, Pakistan
| | - Gang Liu
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China.
| | - Paul W J J van der Wielen
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University, P.O. Box 8033, 6700, EH, Wageningen, the Netherlands
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, the Netherlands; Michigan State University, 1405, S Harrison Rd East-Lansing, 48823, USA
| | - Jan Peter van der Hoek
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, the Netherlands; Waternet, Korte Ouderkerkerdijk 7, 1096 AC, Amsterdam, the Netherlands
| |
Collapse
|
31
|
Dai Z, Sevillano-Rivera MC, Calus ST, Bautista-de Los Santos QM, Eren AM, van der Wielen PWJJ, Ijaz UZ, Pinto AJ. Disinfection exhibits systematic impacts on the drinking water microbiome. MICROBIOME 2020; 8:42. [PMID: 32197656 PMCID: PMC7085177 DOI: 10.1186/s40168-020-00813-0] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 02/25/2020] [Indexed: 05/06/2023]
Abstract
Limiting microbial growth during drinking water distribution is achieved either by maintaining a disinfectant residual or through nutrient limitation without using a disinfectant. The impact of these contrasting approaches on the drinking water microbiome is not systematically understood. We use genome-resolved metagenomics to compare the structure, metabolic traits, and population genomes of drinking water microbiome samples from bulk drinking water across multiple full-scale disinfected and non-disinfected drinking water systems. Microbial communities cluster at the structural- and functional potential-level based on the presence/absence of a disinfectant residual. Disinfectant residual alone explained 17 and 6.5% of the variance in structure and functional potential of the drinking water microbiome, respectively, despite including multiple drinking water systems with variable source waters and source water communities and treatment strategies. The drinking water microbiome is structurally and functionally less diverse and variable across disinfected compared to non-disinfected systems. While bacteria were the most abundant domain, archaea and eukaryota were more abundant in non-disinfected and disinfected systems, respectively. Community-level differences in functional potential were driven by enrichment of genes associated with carbon and nitrogen fixation in non-disinfected systems and γ-aminobutyrate metabolism in disinfected systems likely associated with the recycling of amino acids. Genome-level analyses for a subset of phylogenetically-related microorganisms suggests that disinfection selects for microorganisms capable of using fatty acids, presumably from microbial decay products, via the glyoxylate cycle. Overall, we find that disinfection exhibits systematic selective pressures on the drinking water microbiome and may select for microorganisms able to utilize microbial decay products originating from disinfection-inactivated microorganisms. Video abstract.
Collapse
Affiliation(s)
- Zihan Dai
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | | | - Szymon T Calus
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | | | - A Murat Eren
- Department of Medicine, University of Chicago, Chicago, IL, USA
- Josephine Bay Paul Center, Marine Biological Laboratory, Woods Hole, MA, USA
| | - Paul W J J van der Wielen
- KWR Watercycle Research Institute, Nieuwegein, Netherlands
- Laboratory of Microbiology, Wageningen University, Wageningen, Netherlands
| | - Umer Z Ijaz
- Infrastructure and Environment Research Division, School of Engineering, University of Glasgow, G12 8LT, Glasgow, UK
| | - Ameet J Pinto
- Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA.
| |
Collapse
|
32
|
Ji L, Jiang Y, Li G, Zhao X, Wan K. A real-time PCR assay based on a specific mutation of PstS1 gene for detection of M. bovis strains. Biologicals 2020; 64:23-27. [PMID: 31980349 DOI: 10.1016/j.biologicals.2020.01.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2019] [Revised: 01/07/2020] [Accepted: 01/16/2020] [Indexed: 11/25/2022] Open
Abstract
The Mycobacterium tuberculosis complex (MTBC) is composed of several genetically related and pathogenic mycobacterial species, including M. tuberculosis, M. bovis and M.africanum et al. In our previous study, we found that M. bovis strains had a unique SNP located in position 1055 in the sequence of the pstS1 gene in which a T was substituted by a C. In this study, specific primers and MGB probes were designed according to the mutation in PstS1 gene, and a sensitive, specific and rapid real-time PCR assay for M. bovis was established. Then the assay was used to detect M. bovis in simulation samples. The minimum detectable concentration is 101 copies for M. bovis DNA. The standard curve showed correlation coefficient between threshold cycle and PstS1 gene fragment copy number was 0.997 and slope is -3.144. The minimum detectable concentration is 101 cells/ml for simulation sample. In addition, M.bovis strain 93006, 14 clinical BCG stains and 7 clinical M.bovis strain showed positive while the other strains showed negative results, which proved good specificity. This assay had high sensitivity and specificity for identification of M. bovis from the simulation specimens. The assay can be applied for epidemiological and ecological surveillance of M. bovis strains.
Collapse
Affiliation(s)
- Lingyun Ji
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, PR China; Department of Laboratory Medicine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, 200123, PR China
| | - Yi Jiang
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, PR China; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, 310003, PR China.
| | - Guilian Li
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, PR China; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, 310003, PR China
| | - Xiuqin Zhao
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, PR China; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, 310003, PR China
| | - Kanglin Wan
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, 102206, PR China; Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Hangzhou, 310003, PR China
| |
Collapse
|
33
|
Thompson AF, English EL, Nock AM, Willsey GG, Eckstrom K, Cairns B, Bavelock M, Tighe SW, Foote A, Shulman H, Pericleous A, Gupta S, Kadouri DE, Wargo MJ. Characterizing species interactions that contribute to biofilm formation in a multispecies model of a potable water bacterial community. MICROBIOLOGY (READING, ENGLAND) 2020; 166:34-43. [PMID: 31585061 PMCID: PMC7137775 DOI: 10.1099/mic.0.000849] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Accepted: 08/16/2019] [Indexed: 12/17/2022]
Abstract
Microbial biofilms are ubiquitous in drinking water systems, yet our understanding of drinking water biofilms lags behind our understanding of those in other environments. Here, a six-member model bacterial community was used to identify the interactions and individual contributions of each species to community biofilm formation. These bacteria were isolated from the International Space Station potable water system and include Cupriavidus metallidurans, Chryseobacterium gleum, Ralstonia insidiosa, Ralstonia pickettii, Methylorubrum (Methylobacterium) populi and Sphingomonas paucimobilis, but all six species are common members of terrestrial potable water systems. Using reconstituted assemblages, from pairs to all 6 members, community biofilm formation was observed to be robust to the absence of any single species and only removal of the C. gleum/S. paucimobilis pair, out of all 15 possible 2-species subtractions, led to loss of community biofilm formation. In conjunction with these findings, dual-species biofilm formation assays supported the view that the contribution of C. gleum to community biofilm formation was dependent on synergistic biofilm formation with either R. insidiosa or C. metallidurans. These data support a model of multiple, partially redundant species interactions to generate robustness in biofilm formation. A bacteriophage and multiple predatory bacteria were used to test the resilience of the community to the removal of individual members in situ, but the combination of precise and substantial depletion of a single target species was not achievable. We propose that this assemblage can be used as a tractable model to understand the molecular bases of the interactions described here and to decipher other functions of drinking water biofilms.
Collapse
Affiliation(s)
- Alex F. Thompson
- Cellular, Molecular, and Biomedical Sciences Graduate Program, University of Vermont Gradaute College, Burlington, VT 05405, USA
| | - Erika L. English
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
| | - Adam M. Nock
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
- Present address: Host Parasite Interactions Section, Laboratory of Bacteriology, Rocky Mountain Laboratories, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Hamilton, MT, USA
| | - Graham G. Willsey
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
- The Vermont Lung Center, University of Vermont Larner College of Medicine, Burlington, VT 05405, USA
| | - Korin Eckstrom
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
| | - Brynn Cairns
- Department of Natural Sciences, Northern Vermont University, Johnson, VT 05656, USA
| | | | - Scott W. Tighe
- The Vermont Integrated Genomics Resource, University of Vermont Larner College of Medicine, Burlington, VT 05405, USA
| | - Andrea Foote
- Cellular, Molecular, and Biomedical Sciences Graduate Program, University of Vermont Gradaute College, Burlington, VT 05405, USA
| | - Hannah Shulman
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
| | | | - Shilpi Gupta
- Department of Oral Biology, Rutgers School of Dental Medicine, Newark, NJ 07103
| | - Daniel E. Kadouri
- Department of Oral Biology, Rutgers School of Dental Medicine, Newark, NJ 07103
| | - Matthew J. Wargo
- Department of Microbiology and Molecular Genetics, University of Vermont Larner College of Medicin, Burlington, VT 05405, USA
- The Vermont Lung Center, University of Vermont Larner College of Medicine, Burlington, VT 05405, USA
| |
Collapse
|
34
|
Chen L, Ling F, Bakker G, Liu WT, Medema G, van der Meer W, Liu G. Assessing the transition effects in a drinking water distribution system caused by changing supply water quality: an indirect approach by characterizing suspended solids. WATER RESEARCH 2020; 168:115159. [PMID: 31614234 DOI: 10.1016/j.watres.2019.115159] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 10/03/2019] [Accepted: 10/04/2019] [Indexed: 05/16/2023]
Abstract
Worldwide, it is common that the drinking water distribution systems (DWDSs) may be subjected to changes of supply water quality due to the needs of upgrading the treatment processes or switching the source water. However, the potential impacts of quality changed supply water on the stabilized ecological niches within DWDSs and the associated water quality deterioration risks were poorly documented. In the present study, such transition effects caused by changing the supply water quality that resulted from destabilization of biofilm and loose deposits in DWDS were investigated by analyzing the physiochemical and microbiological characteristics of suspended particles before (T0), during (T3-weeks) and after upgrading the treatments (T6-months) in an unchlorinated DWDS in the Netherlands. Our results demonstrated that after 6 months' time the upgraded treatments significantly improved the water quality. Remarkably, water quality deterioration was observed at the initial stage when the quality-improved treated water distributed into the network at T3-weeks, observed as a spike of total suspended solids (TSS, 50-260%), active biomass (ATP, 95-230%) and inorganic elements (e.g. Mn, 130-250%). Furthermore, pyrosequencing results revealed sharp differences in microbial community composition and structure for the bacteria associated with suspended particles between T0 and T3-weeks, which re-stabilized after 6 months at T6-months. The successful capture of transition effects was especially confirmed by the domination of Nitrospira spp. and Polaromonas spp. in the distribution system at T3-weeks, which were detected at rather low relative abundance at treatment plant. Though the transitional effects were captured, this study shows that the introduction of softening and additional filtration did not have an effect on the water quality for the consumer which improved considerably after 6-months' period. The methodology of monitoring suspended particles with MuPFiSs and additional analysis is capable of detecting transitional effects by monitoring the dynamics of suspended particles and its physiochemical and microbiological composition.
Collapse
Affiliation(s)
- Lihua Chen
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands
| | - Fangqiong Ling
- Department of Energy, Environmental and Chemical Engineering, School of Engineering and Applied Science, Washington University in St. Louis, St. Louis, Missouri, 63130, USA
| | - Geo Bakker
- Vitens N.V., P.O. Box 1205, 8001, BE, Zwolle, the Netherlands
| | - Wen-Tso Liu
- Department of Civil and Environmental Engineering, University of Illinois Urbana-Champaign, 205 N. Mathews Ave., Urbana, IL, 61801, USA
| | - Gertjan Medema
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; KWR Watercycle Research Institute, P.O. Box 1072, 3430, BB, Nieuwegein, the Netherlands
| | - Walter van der Meer
- Oasen Water Company, PO BOX 122, 2800, AC, Gouda, the Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500, AE, Enschede, the Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600, GA, Delft, the Netherlands.
| |
Collapse
|
35
|
Gomes IB, Simões LC, Simões M. Influence of surface copper content on Stenotrophomonas maltophilia biofilm control using chlorine and mechanical stress. BIOFOULING 2020; 36:1-13. [PMID: 31997661 DOI: 10.1080/08927014.2019.1708334] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 12/18/2019] [Accepted: 12/18/2019] [Indexed: 06/10/2023]
Abstract
This work aimed to evaluate the action of materials with different copper content (0, 57, 96 and 100%) on biofilm formation and control by chlorination and mechanical stress. Stenotrophomonas maltophilia isolated from drinking water was used as a model microorganism and biofilms were developed in a rotating cylinder reactor using realism-based shear stress conditions. Biofilms were characterized phenotypically and exposed to three control strategies: 10 mg l-1 of free chlorine for 10 min, an increased shear stress (a fluid velocity of 1.5 m s-1 for 30s), and a combination of both treatments. These shock treatments were not effective in biofilm control. The benefits from the use of copper surfaces was found essentially in reducing the numbers of non-damaged cells. Copper materials demonstrated better performance in biofilm prevention than chlorine. In general, copper alloys may have a positive public health impact by reducing the number of non-damaged cells in the water delivered after chlorine exposure.
Collapse
Affiliation(s)
- I B Gomes
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - L C Simões
- CEB-Centre of Biological Engineering, University of Minho, Braga, Portugal
| | - M Simões
- LEPABE, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
36
|
Limited presence of Waddlia chondrophila in drinking water systems in the Netherlands. New Microbes New Infect 2019; 34:100635. [PMID: 32021695 PMCID: PMC6994710 DOI: 10.1016/j.nmni.2019.100635] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 12/04/2019] [Accepted: 12/10/2019] [Indexed: 11/22/2022] Open
Abstract
Waddlia chondrophila is an emerging pathogen belonging to the order of Chlamydiales. This obligate intracellular bacterium was initially isolated from an aborted bovine fetus and is associated with adverse pregnancy outcomes in women. The ability of W. chondrophila to reside and replicate within a range of free-living amoebae implies a possible widespread environmental presence. Potential hosts of W. chondrophila are present in Dutch drinking water. This study therefore investigated the presence of W. chondrophila DNA in drinking water by analysing 59 samples from ten drinking water systems throughout the Netherlands. Samples were taken at three distances from the treatment plant, during both summer and winter. Twelve of the samples were positive, originating from two of the treatment plants, of which three samples were quantifiable.
Collapse
|
37
|
Hu D, Lin W, Zeng J, Wu P, Zhang M, Guo L, Ye C, Wan K, Yu X. Profiling the microbial contamination in aviation fuel from an airport. BIOFOULING 2019; 35:856-869. [PMID: 31603000 DOI: 10.1080/08927014.2019.1671977] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2019] [Revised: 09/14/2019] [Accepted: 09/16/2019] [Indexed: 06/10/2023]
Abstract
Microbial contamination during fuel storage can cause fuel system fouling and corrosion. Characterizing microbial contamination is critical for preventing and solving these problems. In this study, culture-based combing with the culture-independent methods, were used to profile the microbial contamination in aviation fuel. High-throughput sequencing (HTS) modified by propidium monoazide (PMA) revealed a higher diversity of contaminating microorganisms in samples than the culture method. Proteobacteria (47%), Actinobacteria (21%) and Ascomycota (>99%, fungi) were the most abundant phyla, and the neglected archaea was also detected. Additionally, qPCR-based methods revealed all samples contained a heavy level of microbial contamination, which was more accurate than its culturable counterparts, and fungal contamination was still a problem in aviation fuel. The application of a PCR-based method gives deeper insight into microbial contamination in aviation fuel than the conventional culture method, thus using it for regular detection and accurate description of fuel contamination is strongly recommended in the case of explosive microbial growth.
Collapse
Affiliation(s)
- Dong Hu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Wenfang Lin
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Jie Zeng
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Peng Wu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Menglu Zhang
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Lizheng Guo
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Chengsong Ye
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| | - Kun Wan
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
- University of Chinese Academy of Sciences, Beijing, People's Republic of China
| | - Xin Yu
- Key Lab of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen, People's Republic of China
| |
Collapse
|
38
|
Learbuch KLG, Lut MC, Liu G, Smidt H, van der Wielen PWJJ. Legionella growth potential of drinking water produced by a reverse osmosis pilot plant. WATER RESEARCH 2019; 157:55-63. [PMID: 30952008 DOI: 10.1016/j.watres.2019.03.037] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 02/26/2019] [Accepted: 03/18/2019] [Indexed: 05/25/2023]
Abstract
Treatment processes, such as membrane filtration with reverse osmosis (RO), are used to produce drinking water with a high degree of biostability. To our knowledge, the influence of RO water on biofilm formation and growth of L. pneumophila has not yet been investigated. Therefore, this study aimed (i) to determine the Legionella growth potential of (remineralised) RO-water produced by a pilot plant and to compare this to conventional treated groundwater, and (ii) to determine if different pipe materials, in contact with remineralised RO-water, can cause growth of L. pneumophila. The Legionella growth potential of water was determined with the boiler biofilm monitor (BBM) that mimics the flow of water in a premise plumbing system. The Legionella growth potential of materials in contact with remineralised RO-water was determined by using the biomass production potential (BPP)-test. ATP concentrations in the biofilm on the glass rings from the BBM fed with (remineralised) RO water fluctuated around 100 pg ATP cm-2. In contrast, BBMs fed with conventionally treated water resulted in ten-fold higher ATP concentrations in the biofilm. Moreover, conventionally treated water had a Legionella growth potential that was 1000-fold higher than that of (remineralised) RO-water. Furthermore, glass, copper and PVC-C had the lowest biofilm concentrations and Legionella growth potential in the BPP-test, followed by PE-Xb, PE-Xc and PE-100. The highest biofilm concentration and Legionella growth potential were with PVC-P. Hence, our study demonstrated that remineralised RO-water did not enhance growth of L. pneumophila in the BBM that mimics the premises plumbing system. However, when PE or PVC-P materials are used growth of L. pneumophila can still occur in the premises plumbing system despite the high quality of the supplied remineralised RO-water.
Collapse
Affiliation(s)
- K L G Learbuch
- KWR Watercycle Research Institute, Groningenhaven 7, 3433PE, Nieuwegein, the Netherlands.
| | - M C Lut
- Oasen N.V., Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands
| | - G Liu
- Oasen N.V., Nieuwe Gouwe O.Z. 3, 2801 SB, Gouda, the Netherlands; Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA Delft, the Netherlands
| | - H Smidt
- Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE, Wageningen, the Netherlands
| | - P W J J van der Wielen
- KWR Watercycle Research Institute, Groningenhaven 7, 3433PE, Nieuwegein, the Netherlands; Laboratory of Microbiology, Wageningen University & Research, Stippeneng 4, 6708 WE, Wageningen, the Netherlands
| |
Collapse
|
39
|
Loret JF, Dumoutier N. Non-tuberculous mycobacteria in drinking water systems: A review of prevalence data and control means. Int J Hyg Environ Health 2019; 222:628-634. [DOI: 10.1016/j.ijheh.2019.01.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 12/22/2018] [Accepted: 01/06/2019] [Indexed: 02/08/2023]
|
40
|
Bhardwaj N, Bhardwaj SK, Bhatt D, Lim DK, Kim KH, Deep A. Optical detection of waterborne pathogens using nanomaterials. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.02.019] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
41
|
Liu L, Xing X, Hu C, Wang H. One-year survey of opportunistic premise plumbing pathogens and free-living amoebae in the tap-water of one northern city of China. J Environ Sci (China) 2019; 77:20-31. [PMID: 30573084 DOI: 10.1016/j.jes.2018.04.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2017] [Revised: 04/20/2018] [Accepted: 04/20/2018] [Indexed: 05/21/2023]
Abstract
In this study, qPCR was used to quantify opportunistic premise plumbing pathogens (OPPPs) and free-living amoebae in 11 tap water samples collected over four seasons from a city in northern China. Results demonstrated that the average numbers of gene copies of Legionella spp. and Mycobacterium spp. were significantly higher than those of Aeromonas spp. (p < 0.05). Legionella spp. and Mycobacterium spp. were 100% (44/44) positively detected while P. aeruginosa and Aeromonas spp. were 79.54% (35/44) and 77.27% (34/44) positively detected. Legionella pneumophila was only detected in 4 samples (4/44), demonstrating its occasional occurrence. No Mycobacterium avium or Naegleria fowleri was detected in any of the samples. The average gene copy numbers of target OPPPs were the highest in summer, suggesting seasonal prevalence of OPPPs. Average gene copy numbers of OPPPs in the taps of low-use-frequency were higher than in taps of high-use-frequency, but the difference was not significant for some OPPPs (p > 0.05). Moderate negative correlations between the chlorine concentration and the gene copy numbers of OPPPs were observed by Spearman analysis (rs ranged from -0.311 to -0.710, p < 0.05). However, no significant correlations existed between OPPPs and AOC, BDOC, or turbidity. Moderate positive correlations were observed between the target microorganisms, especially for Acanthamoeba spp., through Spearman analysis (p < 0.05). Based on our studies, it is proposed that disinfectant concentration, season, taps with different-use frequency, OPPP species, and potential microbial correlations should be considered for control of OPPPs in tap water.
Collapse
Affiliation(s)
- Lizhong Liu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xueci Xing
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Chun Hu
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| |
Collapse
|
42
|
Liu L, Xing X, Hu C, Wang H, Lyu L. Effect of sequential UV/free chlorine disinfection on opportunistic pathogens and microbial community structure in simulated drinking water distribution systems. CHEMOSPHERE 2019; 219:971-980. [PMID: 30682762 DOI: 10.1016/j.chemosphere.2018.12.067] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 12/04/2018] [Accepted: 12/08/2018] [Indexed: 06/09/2023]
Abstract
Drinking water distribution systems (DWDS) may be a "Trojan Horse" for some waterborne diseases caused by opportunistic pathogens (OPs). In this study, two simulated DWDS inoculated with groundwater were treated with chlorine (Cl2) and ultraviolet/chlorine (UV/Cl2) respectively to compare their effects on the OPs distributed in four different phases (bulk water, biofilms, corrosion products, and loose deposits) of DWDS. 16S rRNA genes sequencing and qPCR were used to profile microbial community and quantify target genes of OPs, respectively. Results showed that UV/Cl2 was more effective than single Cl2 to control the regrowth of OPs in the water with the same residual chlorine concentration. However, the OPs inhabiting the biofilms, corrosion products, and loose deposits seemed to be tolerant to UV/Cl2 and Cl2, demonstrating that OPs residing in these phases were resistant to the disinfection processes. Some significant microbial correlations between OPs and Acanthamoeba were found by Spearman correlative analysis (p < 0.05), demonstrating that the ecological interactions may exist in the DWDS. 16S rRNA genes sequencing of water samples revealed a significant different microbial community structure between UV/Cl2 and Cl2. This study may give some implications for controlling the OPs in the DWDS disinfected with UV/Cl2.
Collapse
Affiliation(s)
- Lizhong Liu
- Key Laboratory of Aquatic Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; State Key Laboratory of Nuclear Resources and Environment, East China University of Technology, Nanchang City, Jiangxi 330013, China; School of Water Resource and Environmental Engineering, East China University of Technology, Nanchang City, Jiangxi 330013, China
| | - Xueci Xing
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China.
| | - Chun Hu
- Key Laboratory of Aquatic Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China
| | - Haibo Wang
- Key Laboratory of Aquatic Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Lai Lyu
- Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay, Guangzhou University, Guangzhou 510006, China
| |
Collapse
|
43
|
Richardson M, Rautemaa-Richardson R. Exposure to Aspergillus in Home and Healthcare Facilities' Water Environments: Focus on Biofilms. Microorganisms 2019; 7:E7. [PMID: 30621244 PMCID: PMC6351985 DOI: 10.3390/microorganisms7010007] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 12/20/2018] [Accepted: 12/28/2018] [Indexed: 11/25/2022] Open
Abstract
Aspergillus conida are ubiquitous in the environment, including freshwater, water for bathing, and in drinking water. Vulnerable patients and those suffering from allergic diseases are susceptible to aspergillosis. Avoidance of Aspergillus is of paramount importance. Potential outbreaks of aspergillosis in hospital facilities have been described where the water supply has been implicated. Little is known regarding the risk of exposure to Aspergillus in water. How does Aspergillus survive in water? This review explores the biofilm state of Aspergillus growth based on recent literature and suggests that biofilms are responsible for the persistence of Aspergillus in domestic and healthcare facilities' water supplies.
Collapse
Affiliation(s)
- Malcolm Richardson
- Mycology Reference Centre Manchester, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester M23 9LT, UK.
| | - Riina Rautemaa-Richardson
- Mycology Reference Centre Manchester, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester M23 9LT, UK.
| |
Collapse
|
44
|
Cowman SA, James P, Wilson R, Cookson WOC, Moffatt MF, Loebinger MR. Profiling mycobacterial communities in pulmonary nontuberculous mycobacterial disease. PLoS One 2018; 13:e0208018. [PMID: 30533049 PMCID: PMC6289444 DOI: 10.1371/journal.pone.0208018] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 11/10/2018] [Indexed: 01/05/2023] Open
Abstract
The diagnosis of pulmonary non-tuberculous mycobacterial disease (pNTM) is dependent on the isolation of NTM in culture, which is prone to overgrowth and contamination and may not capture the diversity of mycobacteria present, including rare or unidentified species. This study aimed to develop a culture independent method of detecting and identifying mycobacteria from sputum samples using partial sequencing of the hsp65 gene. DNA was extracted from sputum samples from subjects with pNTM and disease controls. Multiplexed partial sequencing of the hsp65 gene was performed using the Illumina MiSeq and custom primers. A reference database of hsp65 sequences was created for taxonomy assignment. Sequencing results were obtained from 42 subjects (31 cases, 11 controls). Mycobacterial sequences were identified in all subjects. In 90.5% of samples more than one species was found (median 5.5). The species isolated in culture was detected by sequencing in 81% of subjects and was the most abundant species in 62%. The sequencing of NTM from clinical samples reveals a far greater diversity than conventional culture and suggests NTM are present as communities rather than a single species. NTM were found to be present even in the absence of isolation in culture or clinical disease.
Collapse
Affiliation(s)
- Steven A. Cowman
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Host Defence Unit, Royal Brompton Hospital, London, United Kingdom
| | - Phillip James
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Robert Wilson
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Host Defence Unit, Royal Brompton Hospital, London, United Kingdom
| | | | - Miriam F. Moffatt
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
| | - Michael R. Loebinger
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Host Defence Unit, Royal Brompton Hospital, London, United Kingdom
- * E-mail:
| |
Collapse
|
45
|
Chen Y, Hammer EE, Richards VP. Phylogenetic signature of lateral exchange of genes for antibiotic production and resistance among bacteria highlights a pattern of global transmission of pathogens between humans and livestock. Mol Phylogenet Evol 2018; 125:255-264. [DOI: 10.1016/j.ympev.2018.03.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Revised: 03/27/2018] [Accepted: 03/29/2018] [Indexed: 01/08/2023]
|
46
|
Bédard E, Laferrière C, Déziel E, Prévost M. Impact of stagnation and sampling volume on water microbial quality monitoring in large buildings. PLoS One 2018; 13:e0199429. [PMID: 29928013 PMCID: PMC6013212 DOI: 10.1371/journal.pone.0199429] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 06/07/2018] [Indexed: 01/22/2023] Open
Abstract
Microbial drinking water quality can be altered in large buildings, especially after stagnation. In this study, bacterial profiles were generated according to the stagnation time and the volume of water collected at the tap. Successive volumes of cold and hot water were sampled after controlled stagnation periods. Bacterial profiles revealed an important decline (> 2 log) in culturable cells in the first 500 mL sampled from the hot and cold water systems, with a steep decline in the first 15 mL. The strong exponential correlation (R2 ≥ 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the rapid increase in suspended culturable cells measured after a short stagnation of one-hour. Results evidence the contribution of the high surface-to-volume ratio at the point of use and the impact of short stagnation times on the increased bacterial load observed. Simple faucets with minimal internal surface area should be preferred to minimize surface area. Sampling protocol, including sampling volume and prior stagnation, was also shown to impact the resulting culturable cell concentration by more than 1000-fold. Sampling a smaller volume on first draw after stagnation will help maximize recovery of bacteria.
Collapse
Affiliation(s)
- Emilie Bédard
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
- INRS-Institut Armand-Frappier, Laval, QC, Canada
- * E-mail:
| | - Céline Laferrière
- Department of Microbiology and Immunology (Infection control), CHU Ste-Justine, Université de Montréal, Montréal, QC, Canada
| | - Eric Déziel
- INRS-Institut Armand-Frappier, Laval, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montréal, Montréal, QC, Canada
| |
Collapse
|
47
|
Li H, Li S, Tang W, Yang Y, Zhao J, Xia S, Zhang W, Wang H. Influence of secondary water supply systems on microbial community structure and opportunistic pathogen gene markers. WATER RESEARCH 2018; 136:160-168. [PMID: 29501760 DOI: 10.1016/j.watres.2018.02.031] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 02/10/2018] [Accepted: 02/12/2018] [Indexed: 06/08/2023]
Abstract
Secondary water supply systems (SWSSs) refer to the in-building infrastructures (e.g., water storage tanks) used to supply water pressure beyond the main distribution systems. The purpose of this study was to investigate the influence of SWSSs on microbial community structure and the occurrence of opportunistic pathogens, the latter of which are an emerging public health concern. Higher numbers of bacterial 16S rRNA genes, Legionella and mycobacterial gene markers were found in public building taps served by SWSSs relative to the mains, regardless of the flushing practice (P < 0.05). In residential buildings, genes of L. pneumomhila, Acanthamoeba and Vermamoeba vermiformis were primarily detected in tanks and taps compared to the mains. Long water retention time, warm temperature and loss of disinfectant residuals promoted microbial growth and colonization of potential pathogens in SWSSs. Varied levels of microbial community shifts were found in different types of SWSSs during water transportation from the distribution main to taps, highlighting the critical role of SWSSs in shaping the drinking water microbiota. Overall, the results provided insight to factors that might aid in controlling pathogen proliferation in real-world water systems using SWSSs.
Collapse
Affiliation(s)
- Huan Li
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Shang Li
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Wei Tang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yang Yang
- Department of Thoracic Surgery, Tongji University Shanghai Pulmonary Hospital, Shanghai 200433, China
| | - Jianfu Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Weixian Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
48
|
Hijnen WAM, Schurer R, Bahlman JA, Ketelaars HAM, Italiaander R, van der Wal A, van der Wielen PWJJ. Slowly biodegradable organic compounds impact the biostability of non-chlorinated drinking water produced from surface water. WATER RESEARCH 2018; 129:240-251. [PMID: 29153877 DOI: 10.1016/j.watres.2017.10.068] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 10/27/2017] [Accepted: 10/29/2017] [Indexed: 05/16/2023]
Abstract
It is possible to distribute drinking water without a disinfectant residual when the treated water is biologically stable. The objective of this study was to determine the impact of easily and slowly biodegradable compounds on the biostability of the drinking water at three full-scale production plants which use the same surface water, and on the regrowth conditions in the related distribution systems. Easily biodegradable compounds in the drinking water were determined with AOC-P17/Nox during 2012-2015. Slowly biodegradable organic compounds measured as particulate and/or high-molecular organic carbon (PHMOC), were monitored at the inlet and after the different treatment stages of the three treatments during the same period. The results show that PHMOC (300-470 μg C L-1) was approximately 10% of the TOC in the surface water and was removed to 50-100 μg C L-1. The PHMOC in the water consisted of 40-60% of carbohydrates and 10% of proteins. A significant and strong positive correlation was observed for PHMOC concentrations and two recently introduced bioassay methods for slowly biodegradable compounds (AOC-A3 and biomass production potential, BPC14). Moreover, these three parameters in the biological active carbon effluent (BACF) of the three plants showed a positive correlation with regrowth in the drinking water distribution system, which was assessed with Aeromonas, heterotrophic plate counts, coliforms and large invertebrates. In contrast, the AOC-P17/Nox concentrations did not correlate with these regrowth parameters. We therefore conclude that slowly biodegradable compounds in the treated water from these treatment plants seem to have a greater impact on regrowth in the distribution system than easily biodegradable compounds.
Collapse
Affiliation(s)
- W A M Hijnen
- Evides Water Company, PO Box 4472, 3006 AL Rotterdam, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands.
| | - R Schurer
- Evides Water Company, PO Box 4472, 3006 AL Rotterdam, The Netherlands
| | - J A Bahlman
- Evides Water Company, PO Box 4472, 3006 AL Rotterdam, The Netherlands
| | - H A M Ketelaars
- Evides Water Company, PO Box 4472, 3006 AL Rotterdam, The Netherlands
| | - R Italiaander
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands
| | - A van der Wal
- Evides Water Company, PO Box 4472, 3006 AL Rotterdam, The Netherlands; Department of Environmental Technology, Wageningen University, Bornse Weilanden 9, 6708 WG Wageningen, The Netherlands
| | - P W J J van der Wielen
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands; Laboratory of Microbiology, Wageningen University, Dreijenplein 10, 6703 HB Wageningen, The Netherlands
| |
Collapse
|
49
|
van der Kooij D, Veenendaal HR, van der Mark EJ, Dignum M. Assessment of the microbial growth potential of slow sand filtrate with the biomass production potential test in comparison with the assimilable organic carbon method. WATER RESEARCH 2017; 125:270-279. [PMID: 28865376 DOI: 10.1016/j.watres.2017.06.086] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 06/26/2017] [Accepted: 06/30/2017] [Indexed: 06/07/2023]
Abstract
Slow sand filtration is the final treatment step at four surface-water supplies in the Netherlands. The microbial growth potential (MGP) of the finished water was measured with the assimilable organic carbon (AOC) method using pure cultures and the biomass production potential (BPP) test. In the BPP test, water samples were incubated untreated at 25 °C and the active-biomass concentration was measured by adenosine tri-phosphate (ATP) analysis. Addition of a river-water inoculum improved the test performance and characteristic growth and maintenance profiles of the water were obtained. The maximum ATP concentration attained within seven days and the cumulative biomass production after 14 days of incubation (BPC14, d ng ATP L-1) showed highly significant and strong linear relationships with the AOC in the slow sand filtrates. The lowest AOC and BPC14 levels were observed in the supplies applying dune filtration without ozonation in post treatment, with AOC/TOC = 1.7 ± 0.3 μg acetate-C equivalents mg-1 C and BPC14/TOC = 16.3 ± 2.2 d ng ATP mg-1 C, corresponding with 1.2 ± 0.19 ng ATP mg-1 C. These characteristics may represent the lowest specific MGP of natural organic matter achievable by biofiltration at temperatures ≤20 °C. The AOC and BPC14 concentrations in the slow sand filtrate of the supply treating lake water by ozonation with granular-activated-carbon filtration and slow sand filtration as post treatment increased with decreasing temperature. The BPP test revealed that this slow sand filtrate sampled at 2 °C contained growth-promoting compounds that were not detected with the AOC test. These observations demonstrate the utility of the BPP test for assessing the MGP of drinking water and show the performance limits of biofiltration for MGP reduction.
Collapse
Affiliation(s)
- Dick van der Kooij
- KWR Watercycle Research Institute, PO Box 1072, 3430 BB Nieuwegein, The Netherlands.
| | - Harm R Veenendaal
- KWR Watercycle Research Institute, PO Box 1072, 3430 BB Nieuwegein, The Netherlands.
| | | | - Marco Dignum
- Waternet, PO Box 94370, 1090 GJ Amsterdam, The Netherlands.
| |
Collapse
|
50
|
Liu G, Tao Y, Zhang Y, Lut M, Knibbe WJ, van der Wielen P, Liu W, Medema G, van der Meer W. Hotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system. WATER RESEARCH 2017; 124:435-445. [PMID: 28787681 DOI: 10.1016/j.watres.2017.08.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Revised: 08/02/2017] [Accepted: 08/02/2017] [Indexed: 05/26/2023]
Abstract
Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This precludes an in-depth understanding of water quality deterioration and the development of proactive management strategies. The present study quantitatively evaluated the distribution of elements, ATP, Aeromonas spp., and bacterial communities in distribution pipes (PVC-U, D = 110 mm, loose deposit and biofilm niches) and household connection pipes (HDPE, D = 32 mm, HDPE biofilm niches) at ten locations in an unchlorinated distribution system. The results show that loose deposits in PVC-U pipes, acting as sinks, constitute a hotspot (highest total amount per meter pipe) for elements, ATP, and target bacteria groups (e.g., Aeromonas spp., Mycobacterium spp., and Legionella spp.). When drinking water distribution system niches with harbored elements and microbes become sources in the event of disturbances, the highest quality deterioration potential (QDP) is that of HDPE biofilm; this can be attributed to its high surface-to-volume ratio. 16s rRNA analysis demonstrates that, at the genus level, the bacterial communities in the water, loose deposits, PVC-U biofilm, and HDPE biofilm were dominated, respectively, by Polaromonas spp. (2-23%), Nitrosipra spp. (1-47%), Flavobacterium spp. (1-36%), and Flavobacterium spp. (5-67%). The combined results of elemental composition and bacterial community analyses indicate that different dominant bio-chemical processes might occur within the different niches-for example, iron-arsenic oxidizing in loose deposits, bio-calumniation in PVC-U biofilm, and methane oxidizing in HDPE biofilm. The release of 20% loose deposits, 20% PVC-U biofilm and 10% HDPE biofilm will cause significant changes of water bacterial community.
Collapse
Affiliation(s)
- Gang Liu
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands.
| | - Yu Tao
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2AZ, United Kingdom
| | - Ya Zhang
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Maarten Lut
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands
| | | | - Paul van der Wielen
- KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands; Laboratory of Microbiology, Wageningen University, P.O. Box 8033, 6700 EH, Wageningen, The Netherlands
| | - Wentso Liu
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Avenue, Urbana, IL, 61801, United States
| | - Gertjan Medema
- Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600GA, Delft, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB, Nieuwegein, The Netherlands
| | - Walter van der Meer
- Oasen Water Company, P.O. Box 122, 2800AC, Gouda, The Netherlands; Science and Technology, University of Twente, P.O. Box 217, 7500AE, Enschede, The Netherlands
| |
Collapse
|