1
|
Xi H, Ross KE, Hinds J, Molino PJ, Whiley H. Efficacy of chlorine-based disinfectants to control Legionella within premise plumbing systems. WATER RESEARCH 2024; 259:121794. [PMID: 38824796 DOI: 10.1016/j.watres.2024.121794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/14/2024] [Accepted: 05/16/2024] [Indexed: 06/04/2024]
Abstract
Legionella is an opportunistic waterborne pathogen that causes Legionnaires' disease. It poses a significant public health risk, especially to vulnerable populations in health care facilities. It is ubiquitous in manufactured water systems and is transmitted via inhalation or aspiration of aerosols/water droplets generated from water fixtures (e.g., showers and hand basins). As such, the effective management of premise plumbing systems (building water systems) in health care facilities is essential for reducing the risk of Legionnaires' disease. Chemical disinfection is a commonly used control method and chlorine-based disinfectants, including chlorine, chloramine, and chlorine dioxide, have been used for over a century. However, the effectiveness of these disinfectants in premise plumbing systems is affected by various interconnected factors that can make it challenging to maintain effective disinfection. This systematic literature review identifies all studies that have examined the factors impacting the efficacy and decay of chlorine-based disinfectant within premise plumbing systems. A total of 117 field and laboratory-based studies were identified and included in this review. A total of 20 studies directly compared the effectiveness of the different chlorine-based disinfectants. The findings from these studies ranked the typical effectiveness as follows: chloramine > chlorine dioxide > chlorine. A total of 26 factors were identified across 117 studies as influencing the efficacy and decay of disinfectants in premise plumbing systems. These factors were sorted into categories of operational factors that are changed by the operation of water devices and fixtures (such as stagnation, temperature, water velocity), evolving factors which are changed in-directly (such as disinfectant concentration, Legionella disinfectant resistance, Legionella growth, season, biofilm and microbe, protozoa, nitrification, total organic carbon(TOC), pH, dissolved oxygen(DO), hardness, ammonia, and sediment and pipe deposit) and stable factors that are not often changed(such as disinfectant type, pipe material, pipe size, pipe age, water recirculating, softener, corrosion inhibitor, automatic sensor tap, building floor, and construction activity). A factor-effect map of each of these factors and whether they have a positive or negative association with disinfection efficacy against Legionella in premise plumbing systems is presented. It was also found that evaluating the effectiveness of chlorine disinfection as a water risk management strategy is further complicated by varying disinfection resistance of Legionella species and the form of Legionella (culturable/viable but non culturable, free living/biofilm associated, intracellular replication within amoeba hosts). Future research is needed that utilises sensors and other approaches to measure these key factors (such as pH, temperature, stagnation, water age and disinfection residual) in real time throughout premise plumbing systems. This information will support the development of improved models to predict disinfection within premise plumbing systems. The findings from this study will inform the use of chlorine-based disinfection within premise plumbing systems to reduce the risk of Legionnaires disease.
Collapse
Affiliation(s)
- Hao Xi
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia.
| | - Kirstin E Ross
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Jason Hinds
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia; Enware Pty Ltd, Caringbah, NSW, Australia
| | | | - Harriet Whiley
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia; ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
2
|
LeChevallier MW, Prosser T, Stevens M. Opportunistic Pathogens in Drinking Water Distribution Systems-A Review. Microorganisms 2024; 12:916. [PMID: 38792751 PMCID: PMC11124194 DOI: 10.3390/microorganisms12050916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 04/24/2024] [Accepted: 04/25/2024] [Indexed: 05/26/2024] Open
Abstract
In contrast to "frank" pathogens, like Salmonella entrocolitica, Shigella dysenteriae, and Vibrio cholerae, that always have a probability of disease, "opportunistic" pathogens are organisms that cause an infectious disease in a host with a weakened immune system and rarely in a healthy host. Historically, drinking water treatment has focused on control of frank pathogens, particularly those from human or animal sources (like Giardia lamblia, Cryptosporidium parvum, or Hepatitis A virus), but in recent years outbreaks from drinking water have increasingly been due to opportunistic pathogens. Characteristics of opportunistic pathogens that make them problematic for water treatment include: (1) they are normally present in aquatic environments, (2) they grow in biofilms that protect the bacteria from disinfectants, and (3) under appropriate conditions in drinking water systems (e.g., warm water, stagnation, low disinfectant levels, etc.), these bacteria can amplify to levels that can pose a public health risk. The three most common opportunistic pathogens in drinking water systems are Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. This report focuses on these organisms to provide information on their public health risk, occurrence in drinking water systems, susceptibility to various disinfectants, and other operational practices (like flushing and cleaning of pipes and storage tanks). In addition, information is provided on a group of nine other opportunistic pathogens that are less commonly found in drinking water systems, including Aeromonas hydrophila, Klebsiella pneumoniae, Serratia marcescens, Burkholderia pseudomallei, Acinetobacter baumannii, Stenotrophomonas maltophilia, Arcobacter butzleri, and several free-living amoebae including Naegleria fowleri and species of Acanthamoeba. The public health risk for these microbes in drinking water is still unclear, but in most cases, efforts to manage Legionella, mycobacteria, and Pseudomonas risks will also be effective for these other opportunistic pathogens. The approach to managing opportunistic pathogens in drinking water supplies focuses on controlling the growth of these organisms. Many of these microbes are normal inhabitants in biofilms in water, so the attention is less on eliminating these organisms from entering the system and more on managing their occurrence and concentrations in the pipe network. With anticipated warming trends associated with climate change, the factors that drive the growth of opportunistic pathogens in drinking water systems will likely increase. It is important, therefore, to evaluate treatment barriers and management activities for control of opportunistic pathogen risks. Controls for primary treatment, particularly for turbidity management and disinfection, should be reviewed to ensure adequacy for opportunistic pathogen control. However, the major focus for the utility's opportunistic pathogen risk reduction plan is the management of biological activity and biofilms in the distribution system. Factors that influence the growth of microbes (primarily in biofilms) in the distribution system include, temperature, disinfectant type and concentration, nutrient levels (measured as AOC or BDOC), stagnation, flushing of pipes and cleaning of storage tank sediments, and corrosion control. Pressure management and distribution system integrity are also important to the microbial quality of water but are related more to the intrusion of contaminants into the distribution system rather than directly related to microbial growth. Summarizing the identified risk from drinking water, the availability and quality of disinfection data for treatment, and guidelines or standards for control showed that adequate information is best available for management of L. pneumophila. For L. pneumophila, the risk for this organism has been clearly established from drinking water, cases have increased worldwide, and it is one of the most identified causes of drinking water outbreaks. Water management best practices (e.g., maintenance of a disinfectant residual throughout the distribution system, flushing and cleaning of sediments in pipelines and storage tanks, among others) have been shown to be effective for control of L. pneumophila in water supplies. In addition, there are well documented management guidelines available for the control of the organism in drinking water distribution systems. By comparison, management of risks for Mycobacteria from water are less clear than for L. pneumophila. Treatment of M. avium is difficult due to its resistance to disinfection, the tendency to form clumps, and attachment to surfaces in biofilms. Additionally, there are no guidelines for management of M. avium in drinking water, and one risk assessment study suggested a low risk of infection. The role of tap water in the transmission of the other opportunistic pathogens is less clear and, in many cases, actions to manage L. pneumophila (e.g., maintenance of a disinfectant residual, flushing, cleaning of storage tanks, etc.) will also be beneficial in helping to manage these organisms as well.
Collapse
Affiliation(s)
| | - Toby Prosser
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| | - Melita Stevens
- Melbourne Water, Melbourne, VIC 3001, Australia; (T.P.); (M.S.)
| |
Collapse
|
3
|
Yang J, Hu Y, Zhang Y, Zhou S, Meng D, Xia S, Wang H. Deciphering the diversity and assemblage mechanisms of nontuberculous mycobacteria community in four drinking water distribution systems with different disinfectants. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 907:168176. [PMID: 37907107 DOI: 10.1016/j.scitotenv.2023.168176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/25/2023] [Accepted: 10/26/2023] [Indexed: 11/02/2023]
Abstract
Nontuberculous mycobacteria (NTM) represent an emerging health concern due to their escalating infections worldwide. Although drinking water distribution systems (DWDSs) have been considered as NTM reservoirs and a potential infection route, NTM community at the species level remain largely elusive in DWDSs. This study employed high-throughput sequencing coupled with qPCR to profile NTM community and estimate their abundances at the species level in water and biofilm samples in four DWDSs using three different disinfectants (i.e. free chlorine, chloramine and chlorine dioxide). Results demonstrated the dominance of Mycobacterium paragordonae and Mycobacterium mucogenicum in both biofilm and water across four DWDSs, whereas Mycobacterium abscessus and Mycobacterium chelonae, the two clinically significant species, exhibited low abundance but high prevalence. Comparable NTM community was observed in biofilm across these four DWDSs. Distinct separation of NTM community between SH-chloramine DWDSs water and other DWDSs highlighted the selective pressure of chloramine on NTM community. Furthermore, the research revealed that biofilm and water exhibited distinct NTM community structures, with biofilm harboring more diverse NTM community. Certain NTM species displayed a preference for biofilm, such as Mycobacterium gordonae, while others, like Mycobacterium mucogenicum, were more abundant in water samples (P < 0.05). In terms of NTM community assembly, stochastic processes dominated biofilm, while comparable role of stochastic and deterministic processes was observed in water. In conclusion, this study offers a pioneering and comprehensive insight into the dynamics and assembly mechanisms of NTM community within four DWDSs treated with three distinct disinfectants. These findings serve as a critical foundation for assessing NTM exposure risks and devising effective management strategies within DWDSs.
Collapse
Affiliation(s)
- Jinhao Yang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yuxing Hu
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Yue Zhang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Shuang Zhou
- School of Medicine, Tongji University, Shanghai 200092, China
| | - Die Meng
- Shanghai Pulmonary Hospital, Tongji University, Shanghai 200433, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
4
|
Cullom A, Spencer MS, Williams MD, Falkinham JO, Brown C, Edwards MA, Pruden A. Premise Plumbing Pipe Materials and In-Building Disinfectants Shape the Potential for Proliferation of Pathogens and Antibiotic Resistance Genes. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:21382-21394. [PMID: 38071676 DOI: 10.1021/acs.est.3c05905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2023]
Abstract
In-building disinfectants are commonly applied to control the growth of pathogens in plumbing, particularly in facilities such as hospitals that house vulnerable populations. However, their application has not been well optimized, especially with respect to interactive effects with pipe materials and potential unintended effects, such as enrichment of antibiotic resistance genes (ARGs) across the microbial community. Here, we used triplicate convectively mixed pipe reactors consisting of three pipe materials (PVC, copper, and iron) for replicated simulation of the distal reaches of premise plumbing and evaluated the effects of incrementally increased doses of chlorine, chloramine, chlorine dioxide, and copper-silver disinfectants. We used shotgun metagenomic sequencing to characterize the resulting succession of the corresponding microbiomes over the course of 37 weeks. We found that both disinfectants and pipe material affected ARG and microbial community taxonomic composition both independently and interactively. Water quality and total bacterial numbers were not found to be predictive of pathogenic species markers. One result of particular concern was the tendency of disinfectants, especially monochloramine, to enrich ARGs. Metagenome assembly indicated that many ARGs were enriched specifically among the pathogenic species. Functional gene analysis was indicative of a response of the microbes to oxidative stress, which is known to co/cross-select for antibiotic resistance. These findings emphasize the need for a holistic evaluation of pathogen control strategies for plumbing.
Collapse
Affiliation(s)
- Abraham Cullom
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Matheu Storme Spencer
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Myra D Williams
- Department of Biological Sciences, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Joseph O Falkinham
- Department of Biological Sciences, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Connor Brown
- Department of Genetics, Bioinformatics, and Computational Biology, Virginia Tech, Blacksburg, Virginia 24061, United States
| | - Marc A Edwards
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 418 Durham Hall, Blacksburg, Virginia 24061, United States
| |
Collapse
|
5
|
Wang M, Wang H, Hu C, Deng J, Shi B. Phthalate acid esters promoted the enrichment of chlorine dioxide-resistant bacteria and their functions related to human diseases in rural polyvinyl chloride distribution pipes. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 896:165282. [PMID: 37406691 DOI: 10.1016/j.scitotenv.2023.165282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/09/2023] [Accepted: 07/01/2023] [Indexed: 07/07/2023]
Abstract
Polyvinyl chloride (PVC) pipes are widely used as drinking water distribution pipes in rural areas of China. However, whether phthalate acid esters (PAEs) released from PVC pipes will affect tap water quality is still unknown. The influence of released PAEs on the water quality was analysed in this study, especially after ClO2 disinfection. The results indicated that ClO2 disinfection could control the growth of total coliforms and heterotrophic bacteria (HPC). However, when the ClO2 residual decreased to below 0.10 mg/L, HPC and opportunistic pathogens, including Mycobacterium avium and Pseudomonas aeruginosa, increased significantly. In addition, after ClO2 disinfection, PAEs concentrations increased from 10.6-22.2 μg/L to 21.2-58.8 μg/L in different sampling cites. Linear discriminant analysis (LDA) effect size (LEfSe) and statistical analysis of metagenomic profiles (Stamp) showed that ClO2 disinfection induced the enrichment of Pseudomonas, Bradyrhizobium, and Mycobacterium and functions related to human diseases, such as pathogenic Escherichia coli infection, shigellosis, Staphylococcus aureus infection, and Vibrio cholerae infection. The released PAEs not only promoted the growth of these ClO2-resistant bacterial genera but also enhanced their functions related to human diseases. Moreover, these PAEs also induced the enrichment of other bacterial genera, such as Blastomonas, Dechloromonas, and Kocuria, and their functions, such as chronic myeloid leukaemia, African trypanosomiasis, leishmaniasis, hepatitis C and human T-cell leukaemia virus 1 infection. The released PAEs enhanced the microbial risk of the drinking water. These results are meaningful for guaranteeing water quality in rural areas of China.
Collapse
Affiliation(s)
- Min Wang
- Institute of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China; Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
| | - Chisheng Hu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Jianmian Deng
- Institute of Environmental and Municipal Engineering, North China University of Water Resources and Electric Power, Zhengzhou 450045, China.
| | - Baoyou Shi
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
6
|
Donohue MJ, Pham M, Brown S, Easwaran KM, Vesper S, Mistry JH. Water quality influences Legionella pneumophila determination. WATER RESEARCH 2023; 238:119989. [PMID: 37137207 PMCID: PMC10351031 DOI: 10.1016/j.watres.2023.119989] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 04/18/2023] [Accepted: 04/20/2023] [Indexed: 05/05/2023]
Abstract
Legionellosis is a respiratory disease of public health concern. The bacterium Legionella pneumophila is the etiologic agent responsible for >90% of legionellosis cases in the United States. Legionellosis transmission primarily occurs through the inhalation or aspiration of contaminated water aerosols or droplets. Therefore, a thorough understanding of L. pneumophila detection methods and their performance in various water quality conditions is needed to develop preventive measures. Two hundred and nine potable water samples were collected from taps in buildings across the United States. L. pneumophila was determined using three culture methods: Buffered Charcoal Yeast Extract (BCYE) culture with Matrix-assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS) identification, Legiolert® 10- and 100-mL tests, and one molecular method: quantitative Polymerase Chain Reaction (qPCR) assay. Culture and molecular positive results were confirmed by secondary testing including MALDI-MS. Eight water quality variables were studied, including source water type, secondary disinfectant, total chlorine residual, heterotrophic bacteria, total organic carbon (TOC), pH, water hardness, cold- and hot-water lines. The eight water quality variables were segmented into 28 categories, based on scale and ranges, and method performance was evaluated in each of these categories. Additionally, a Legionella genus qPCR assay was used to determine the water quality variables that promote or hinder Legionella spp. occurrence. L. pneumophila detection frequency ranged from 2 to 22% across the methods tested. Method performance parameters of sensitivity, specificity, positive and negative predictive values, and accuracy were >94% for the qPCR method but ranged from 9 to 100% for the culture methods. Water quality influenced L. pneumophila determination by culture and qPCR methods. L. pneumophila qPCR detection frequencies positively correlated with TOC and heterotrophic bacterial counts. The source water-disinfectant combination influenced the proportion of Legionella spp. that is L. pneumophila. Water quality influences L. pneumophila determination. To accurately detect L. pneumophila, method selection should consider the water quality in addition to the purpose of testing (general environmental monitoring versus disease-associated investigations).
Collapse
Affiliation(s)
- Maura J Donohue
- United States Environmental Protection Agency, Cincinnati, OH 45268, USA.
| | - Maily Pham
- United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Stephanie Brown
- United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | | | - Stephen Vesper
- United States Environmental Protection Agency, Cincinnati, OH 45268, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, TX 75270, USA
| |
Collapse
|
7
|
Chapman M, Barnes AN. A scoping review of waterborne and water-related disease in the Florida environment from 1999 to 2022. REVIEWS ON ENVIRONMENTAL HEALTH 2023:reveh-2022-0249. [PMID: 37148256 DOI: 10.1515/reveh-2022-0249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 04/17/2023] [Indexed: 05/08/2023]
Abstract
Florida's environments are suitable reservoirs for many disease-causing agents. Pathogens and toxins in Florida waterways have the potential to infect mosquito vectors, animals, and human hosts. Through a scoping review of the scientific literature published between 1999 and 2022, we examined the presence of water-related pathogens, toxins, and toxin-producers in the Florida environment and the potential risk factors for human exposure. Nineteen databases were searched using keywords relating to the waterborne, water-based toxins, and water-related vector-borne diseases which are reportable to the Florida Department of Health. Of the 10,439 results, 84 titles were included in the final qualitative analysis. The resulting titles included environmental samples of water, mosquitoes, algae, sand, soil/sediment, air, food, biofilm, and other media. Many of the waterborne, water-related vector-borne, and water-based toxins and toxin-producers of public health and veterinary importance from our search were found to be present in Florida environments. Interactions with Florida waterways can expose humans and animals to disease and toxins due to nearby human and/or animal activity, proximal animal or human waste, failing or inadequate water and/or sanitation, weather patterns, environmental events, and seasonality, contaminated food items, preference of agent for environmental media, high-risk populations, urban development and population movement, and unregulated and unsafe environmental activities. A One Health approach will be imperative to maintaining healthy waterways and shared environments throughout the state to protect the health of humans, animals, and our ecosystems.
Collapse
Affiliation(s)
- McKinley Chapman
- Department of Public Health, University of North Florida, Jacksonville, FL, USA
| | - Amber N Barnes
- Department of Public Health, University of North Florida, Jacksonville, FL, USA
| |
Collapse
|
8
|
Effect of UV Light and Sodium Hypochlorite on Formation and Destruction of Pseudomonas fluorescens Biofilm In Vitro. Processes (Basel) 2022. [DOI: 10.3390/pr10101901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Pseudomonas fluorescens is one of the first colonizers of bacterial biofilm in water systems and a member of opportunistic premise plumbing pathogens (OPPPs). The aim of this study was to examine the effect of UV light and sodium hypochlorite on the formation and destruction of mature P. fluorescens biofilm on ceramic tiles. Planktonic bacteria or bacteria in mature biofilm were exposed to UV light (254 nm) for 5, 20 s. and to 0.4 mg/L sodium hypochlorite for 1 min. Mature biofilm was also exposed to increased concentration of sodium hypochlorite of 2 mg/L for 0.5, 1 and 2 h and combined with UV. Prolonged action of sodium hypochlorite and an increase in its concentration in combination with UV gave the best results in the inhibition of biofilm formation after the pre-treatment and destruction of mature biofilm. The effect of hyperchlorination in combination with UV radiation shows better results after a long exposure time, although even after 120 min there was no completely destroyed biofilm. Furthermore, the mechanism of the effect of combined methods should be explored as well as the importance of mechanical cleaning that is crucial in combating bacterial biofilm in swimming pools.
Collapse
|
9
|
Nilsen NS, Uldum SA. Legionella colonisation in hot water systems in care homes from two Danish municipalities. JOURNAL OF WATER AND HEALTH 2022; 20:1393-1404. [PMID: 36170193 DOI: 10.2166/wh.2022.116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Legionnaires' disease is a serious health risk among the elderly. Water systems in care homes are therefore of particular interest. We investigated the levels of culturable Legionella in the hot water systems in care homes in two Danish municipalities. Two hundred and sixty-eight water samples from 98 care homes were evaluated. Contents of culturable Legionella counts were calculated, and correlations between temperature and colony-forming units (CFU/L) were analysed. Seventy-seven and 81%, respectively, of the care homes were colonised with Legionella in the two municipalities. Most care homes had less than 1,000 CFU/L, but 13 and 16% had more than 10,000 CFU/L. When including first flush samples, 27% of the care homes in Municipality 1 had Legionella levels above 10,000 CFU/L. Temperatures of ≥50 °C in Municipality 1 and ≥55 °C in Municipality 2 correlated with low levels of Legionella. The content of Legionella colonies was significantly higher in care homes in Municipality 1. However, a significantly higher proportion of taps in Municipality 2 had Legionella colonies. In conclusion, temperatures should be raised to 55 °C to avoid high Legionella levels. Test procedures should be evaluated, and the regular use of taps and routine testing for Legionella should be taken into consideration.
Collapse
Affiliation(s)
- Niss Skov Nilsen
- Danish Building Research Institute (Build), Division of Sustainability, Energy and Indoor Environment in Buildings, Aalborg University, A.C. Meyers Vaenge 15, 2450 Copenhagen SV, Denmark E-mail:
| | - Søren Anker Uldum
- Department of Bacteria, Parasites and Fungi, Statens Serum Institut (SSI), Artillerivej 5, 2300 Copenhagen S, Denmark
| |
Collapse
|
10
|
Donohue MJ, Mistry JH, Tucker N, Vesper SJ. Hot water plumbing in residences and office buildings have distinctive risk of Legionella pneumophila contamination. Int J Hyg Environ Health 2022; 245:114023. [PMID: 36058110 PMCID: PMC9848435 DOI: 10.1016/j.ijheh.2022.114023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 07/22/2022] [Accepted: 08/09/2022] [Indexed: 01/21/2023]
Abstract
AIM To observe how Legionella pneumophila, the causative agent for legionellosis, can transmit through the hot water plumbing of residences and office buildings. METHOD AND RESULTS Using qPCR, L. pneumophila and L. pneumophila Serogroup (Sg)1 were measured in hot water samples collected from 100 structures, consisting of 70 residences and 30 office buildings. The hot water samples collected from office buildings had a higher L. pneumophila detection frequency of 53% (16/30) than residences, with a 103 GU/L (median) concentration. An office building's age was not a statistically significant predictor of contamination, but its area (>100,000 sq. ft.) was, P = <0.001. Hot water samples collected at residences had a lower L. pneumophila detection frequency of 36% (25/70) than office buildings, with a 100 GU/L (median) concentration. A residence's age was a significant predictor of contamination, P = 0.009, but not its area. The water's secondary disinfectant type did not affect L. pneumophila detection frequency nor its concentration in residences, but the secondary disinfectant type did affect results in office buildings. Legionella pneumophila's highest detection frequencies were in samples collected in March-August for office buildings and in June-November for residences. CONCLUSION This study revealed that the built environment influences L. pneumophila transport and fate. Residential plumbing could be a potential "conduit" for L. pneumophila exposure from a source upstream of the hot water environment. Both old and newly built office buildings had an equal probability of L. pneumophila contamination. Legionella-related remediation efforts in office buildings (that contain commercial functions only) might not significantly improve a community's public health.
Collapse
Affiliation(s)
- Maura J Donohue
- United States Environmental Protection Agency, Cincinnati, OH, 45268, USA.
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, TX, 75270, USA
| | - Nicole Tucker
- United States Environmental Protection Agency, Washington, DC, 20464, USA
| | - Stephen J Vesper
- United States Environmental Protection Agency, Cincinnati, OH, 45268, USA
| |
Collapse
|
11
|
The Presence of Opportunistic Premise Plumbing Pathogens in Residential Buildings: A Literature Review. WATER 2022. [DOI: 10.3390/w14071129] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Opportunistic premise plumbing pathogens (OPPP) are microorganisms that are native to the plumbing environment and that present an emerging infectious disease problem. They share characteristics, such as disinfectant resistance, thermal tolerance, and biofilm formation. The colonisation of domestic water systems presents an elevated health risk for immune-compromised individuals who receive healthcare at home. The literature that has identified the previously described OPPPs (Aeromonas spp., Acinetobacter spp., Helicobacter spp., Legionella spp., Methylobacterium spp., Mycobacteria spp., Pseudomonas spp., and Stenotrophomonas spp.) in residential drinking water systems were systematically reviewed. By applying the Preferred reporting items for systematic reviews and meta-analyses guidelines, 214 studies were identified from the Scopus and Web of Science databases, which included 30 clinical case investigations. Tap components and showerheads were the most frequently identified sources of OPPPs. Sixty-four of these studies detected additional clinically relevant pathogens that are not classified as OPPPs in these reservoirs. There was considerable variation in the detection methods, which included traditional culturing and molecular approaches. These identified studies demonstrate that the current drinking water treatment methods are ineffective against many waterborne pathogens. It is critical that, as at-home healthcare services continue to be promoted, we understand the emergent risks that are posed by OPPPs in residential drinking water. Future research is needed in order to provide consistent data on the prevalence of OPPPs in residential water, and on the incidence of waterborne homecare-associated infections. This will enable the identification of the contributing risk factors, and the development of effective controls.
Collapse
|
12
|
Proctor C, Garner E, Hamilton KA, Ashbolt NJ, Caverly LJ, Falkinham JO, Haas CN, Prevost M, Prevots DR, Pruden A, Raskin L, Stout J, Haig SJ. Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication. WATER RESEARCH 2022; 211:117997. [PMID: 34999316 PMCID: PMC8821414 DOI: 10.1016/j.watres.2021.117997] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 12/13/2021] [Accepted: 12/19/2021] [Indexed: 05/10/2023]
Abstract
In recent years, drinking water-associated pathogens that can cause infections in immunocompromised or otherwise susceptible individuals (henceforth referred to as DWPI), sometimes referred to as opportunistic pathogens or opportunistic premise plumbing pathogens, have received considerable attention. DWPI research has largely been conducted by experts focusing on specific microorganisms or within silos of expertise. The resulting mitigation approaches optimized for a single microorganism may have unintended consequences and trade-offs for other DWPI or other interests (e.g., energy costs and conservation). For example, the ecological and epidemiological issues characteristic of Legionella pneumophila diverge from those relevant for Mycobacterium avium and other nontuberculous mycobacteria. Recent advances in understanding DWPI as part of a complex microbial ecosystem inhabiting drinking water systems continues to reveal additional challenges: namely, how can all microorganisms of concern be managed simultaneously? In order to protect public health, we must take a more holistic approach in all aspects of the field, including basic research, monitoring methods, risk-based mitigation techniques, and policy. A holistic approach will (i) target multiple microorganisms simultaneously, (ii) involve experts across several disciplines, and (iii) communicate results across disciplines and more broadly, proactively addressing source water-to-customer system management.
Collapse
Affiliation(s)
- Caitlin Proctor
- Department of Agricultural and Biological Engineering, Division of Environmental and Ecological Engineering, Purdue University, West Lafayette, IN, USA
| | - Emily Garner
- Wadsworth Department of Civil & Environmental Engineering, West Virginia University, Morgantown, WV, USA
| | - Kerry A Hamilton
- School of Sustainable Engineering and the Built Environment and The Biodesign Centre for Environmental Health Engineering, Arizona State University, Tempe, AZ, USA
| | - Nicholas J Ashbolt
- Faculty of Science and Engineering, Southern Cross University, Gold Coast. Queensland, Australia
| | - Lindsay J Caverly
- Department of Pediatrics, University of Michigan Medical School, Ann Arbor, MI, USA
| | | | - Charles N Haas
- Department of Civil, Architectural & Environmental Engineering, Drexel University, Philadelphia, PA, USA
| | - Michele Prevost
- Department of Civil, Geological and Mining Engineering, Polytechnique Montreal, Montreal, Quebec, Canada
| | - D Rebecca Prevots
- Epidemiology Unit, Laboratory of Clinical Immunology and Microbiology, Division of Intramural Research, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD, USA
| | - Amy Pruden
- Department of Civil & Environmental Engineering, Virginia Tech, Blacksburg, VA USA
| | - Lutgarde Raskin
- Department of Civil & Environmental Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Janet Stout
- Department of Civil & Environmental Engineering, University of Pittsburgh, and Special Pathogens Laboratory, Pittsburgh, PA, USA
| | - Sarah-Jane Haig
- Department of Civil & Environmental Engineering, and Department of Environmental & Occupational Health, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
13
|
A Tale of Four Danish Cities: Legionella pneumophila Diversity in Domestic Hot Water and Spatial Variations in Disease Incidence. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19052530. [PMID: 35270223 PMCID: PMC8909801 DOI: 10.3390/ijerph19052530] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 01/27/2023]
Abstract
Denmark has one of the highest Legionnaires' disease notification rates within Europe, averaging 4.7 cases per 100,000 population annually (2017 to 2020). The relatively high incidence of disease is not uniform across the country, and approximately 70% of all domestically acquired cases in Denmark are caused by Legionella pneumophila (LP) strains that are considered less virulent. The aim of this study was to investigate if colonization rates, levels of colonization, and/or types of LP present in hot water systems were associated with geographic differences in Legionnaires' disease incidence. Domestic water systems from four cities in Denmark were analyzed via culture and qPCR. Serogrouping and sequence typing was performed on randomly selected isolates. Single nucleotide polymorphism was used to identify clonal relationship among isolates from the four cities. The results revealed a high LP colonization rate from 68% to 87.5% among systems, composed primarily of non-serogroup 1. LP serogroup 1 reacting with the monoclonal antibody (MAb) 3/1 was not identified in any of the systems tested, while MAb 3/1 negative serogroup 1 strains were isolated from 10 systems (9.6%). We hypothesize that a combination of factors influences the incidence rate of LD in each city, including sequence type and serogroup distribution, colonization rate, concentration of Legionella in Pre-flush and Flush samples, and potentially building characteristics such as water temperature measured at the point of use.
Collapse
|
14
|
Prevalence of opportunistic pathogens in a school building plumbing during periods of low water use and a transition to normal use. Int J Hyg Environ Health 2022; 241:113945. [PMID: 35182850 DOI: 10.1016/j.ijheh.2022.113945] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 01/28/2022] [Accepted: 02/10/2022] [Indexed: 11/23/2022]
Abstract
The spread of opportunistic pathogens via building water supply and plumbing is of public health concern. This study was conducted to better understand microbial water quality changes in a LEED-certified school building during low water use (Summer) and normal water use (Autumn). The copper plumbed building contained water saving devices, a hot water recirculation system, and received chloraminated drinking water from a public water system. Three separate sampling events were conducted during the summer break inside the building and another three sampling events were conducted after the school returned to session. Using quantitative PCR, Legionella spp. were detected in all water samples, followed by Mycobacterium spp. (99%). Mycobacterium avium (75%) and Acanthamoeba spp. (17.5%) throughout the building water system. Legionella pneumophila and Naegleria fowleri were not detected in any of the samples. The mean concentrations of Legionella spp., Mycobacterium spp., Mycobacterium avium, and Acanthamoeba spp. detected in water samples were 3.9, 5.7, 4.7, and 2.8 log10 gene copies per 100 ml, respectively. There was a statistically significantly difference in the mean concentrations of Legionella spp., Mycobacterium spp. and M. avium gene markers in water samples between school breaks and when school was in session. Cultivable Legionella were also detected in water samples collected during periods of low water use. This study highlights the need for routine proactive water quality testing in school buildings to determine the extent of drinking water quality problems associated with plumbing and direct action to remediate microbial colonization.
Collapse
|
15
|
Gleason JA, Cohn PD. A review of legionnaires' disease and public water systems - Scientific considerations, uncertainties and recommendations. Int J Hyg Environ Health 2021; 240:113906. [PMID: 34923288 DOI: 10.1016/j.ijheh.2021.113906] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 12/02/2021] [Accepted: 12/13/2021] [Indexed: 11/17/2022]
Abstract
Legionella is an opportunistic premise plumbing pathogen and causative agent of a severe pneumonia called Legionnaires' Disease (LD). Cases of LD have been on the rise in the U.S. and globally. Although Legionella was first identified 45 years ago, it remains an 'emerging pathogen." Legionella is part of the normal ecology of a public water system and is frequently detected in regulatory-compliant drinking water. Drinking water utilities, regulators and public health alike are increasingly required to have a productive understanding of the evolving issues and complex discussions of the contribution of the public water utility to Legionella exposure and LD risk. This review provides a brief overview of scientific considerations important for understanding this complex topic, a review of findings from investigations of public water and LD, including data gaps, and recommendations for professionals interested in investigating public water utilities. Although the current literature is inconclusive in identifying a public water utility as a sole source of an LD outbreak, the evidence is clear that minimizing growth of Legionella in public water utilities through proper maintenance and sustained disinfectant residuals, throughout all sections of the water utility, will lead to a less conducive environment for growth of the bacteria in the system and the buildings they serve.
Collapse
Affiliation(s)
- Jessie A Gleason
- Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, 135 E. State Street, P.O. Box 369, Trenton, NJ, 08625, USA.
| | - Perry D Cohn
- Retired, Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, PO Box 369, Trenton, NJ, 08625, USA.
| |
Collapse
|
16
|
Zhang C, Struewing I, Mistry JH, Wahman DG, Pressman J, Lu J. Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems. WATER RESEARCH 2021; 205:117571. [PMID: 34628111 PMCID: PMC8629321 DOI: 10.1016/j.watres.2021.117571] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/02/2021] [Accepted: 08/13/2021] [Indexed: 05/06/2023]
Abstract
Water-based opportunistic pathogens (OPs) are a leading cause of drinking-water-related disease outbreaks, especially in developed countries such as the United States (US). Physicochemical water quality parameters, especially disinfectant residuals, control the (re)growth, presence, colonization, and concentrations of OPs in drinking water distribution systems (DWDSs), while the relationship between OPs and those parameters remain unclear. This study aimed to quantify how physicochemical parameters, mainly monochloramine residual concentration, hydraulic residence time (HRT), and seasonality, affected the occurrence and concentrations of four common OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in four full-scale DWDSs in the US. Legionella as a dominant OP occurred in 93.8% of the 64 sampling events and had a mean density of 4.27 × 105 genome copies per liter. Legionella positively correlated with Mycobacterium, Pseudomonas, and total bacteria. Multiple regression with data from the four DWDSs showed that Legionella had significant correlations with total chlorine residual level, free ammonia concentration, and trihalomethane concentration. Therefore, Legionella is a promising indicator of water-based OPs, reflecting microbial water quality in chloraminated DWDSs. The OP concentrations had strong seasonal variations and peaked in winter and/or spring possibly because of reduced water usage (i.e., increased water stagnation or HRT) during cold seasons. The OP concentrations generally increased with HRT presumably because of disinfectant residual decay, indicating the importance of well-maintaining disinfectant residuals in DWDSs for OP control. The concentrations of Mycobacterium, Pseudomonas, and V. vermiformis were significantly associated with total chlorine residual concentration, free ammonia concentration, and pH and trihalomethane concentration, respectively. Overall, this study demonstrates how the significant spatiotemporal variations of OP concentrations in chloraminated DWDSs correlated with critical physicochemical water quality parameters such as disinfectant residual levels. This work also indicates that Legionella is a promising indicator of OPs and microbial water quality in chloraminated DWDSs.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, Ohio, USA
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, Texas, USA
| | - David G Wahman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jonathan Pressman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA.
| |
Collapse
|
17
|
Lytle DA, Pfaller S, Muhlen C, Struewing I, Triantafyllidou S, White C, Hayes S, King D, Lu J. A comprehensive evaluation of monochloramine disinfection on water quality, Legionella and other important microorganisms in a hospital. WATER RESEARCH 2021; 189:116656. [PMID: 33249307 PMCID: PMC8133025 DOI: 10.1016/j.watres.2020.116656] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 11/15/2020] [Accepted: 11/16/2020] [Indexed: 05/22/2023]
Abstract
Opportunistic pathogens such as Legionella are of significant public health concern in hospitals. Microbiological and water chemistry parameters in hot water throughout an Ohio hospital were monitored monthly before and after the installation of a monochloramine disinfection system over 16 months. Water samples from fifteen hot water sampling sites as well as the municipal water supply entering the hospital were analyzed using both culture and qPCR assays for specific microbial pathogens including Legionella, Pseudomonas spp., nontuberculous Mycobacteria [NTM], as well as for heterotrophic bacteria. Legionella culture assays decreased from 68% of all sites being positive prior to monochloramine addition to 6% positive after monochloramine addition, and these trends were parallel to qPCR results. Considering all samples, NTMs by culture were significantly reduced from 61% to 14% positivity (p<0.001) after monochloramine treatment. Mycobacterium genus-specific qPCR positivity was reduced from 92% to 65%, but the change was not significant. Heterotrophic bacteria (heterotrophic bacteria plate counts [HPCs]) exhibited large variability which skewed statistical results on a per room basis. However, when all samples were considered, a significant decrease in HPCs was observed after monochloramine addition. Lastly, Pseudomonas aeruginosa and Vermamoeba vermiformis demonstrated large and significant decrease of qPCR signals post-chloramination. General water chemistry parameters including monochloramine residual, nitrate, nitrite, pH, temperature, metals and total trihalomethanes (TTHMs) were also measured. Significant monochloramine residuals were consistently observed at all sampling sites with very little free ammonia present and no water quality indications of nitrification (e.g., pH decrease, elevated nitrite or nitrate). The addition of monochloramine had no obvious impact on metals (lead, copper and iron) and disinfection by-products.
Collapse
Affiliation(s)
- Darren A Lytle
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States.
| | - Stacy Pfaller
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Christy Muhlen
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Ian Struewing
- U.S. Environmental Protection Agency, ORD, Center for Environmental Measurement and Modelling (CEMM), 26 W. Martin Luther King Drive, Cincinnati, OH 45268, United States
| | - Simoni Triantafyllidou
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Colin White
- Ohio Environmental Protection Agency, Emerging Contaminants Section, Division of Drinking and Ground Waters, 50 West Town Street, Suite 700 Columbus, OH 43215, United States
| | - Sam Hayes
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Dawn King
- U.S. Environmental Protection Agency, ORD, Center for Environmental Solutions and Emergency Response (CESER), 26 W. Martin Luther King Drive, Cincinnati, OH, 45268, United States
| | - Jingrang Lu
- U.S. Environmental Protection Agency, ORD, Center for Environmental Measurement and Modelling (CEMM), 26 W. Martin Luther King Drive, Cincinnati, OH 45268, United States
| |
Collapse
|
18
|
Hozalski RM, LaPara TM, Zhao X, Kim T, Waak MB, Burch T, McCarty M. Flushing of Stagnant Premise Water Systems after the COVID-19 Shutdown Can Reduce Infection Risk by Legionella and Mycobacterium spp. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:15914-15924. [PMID: 33232602 DOI: 10.1021/acs.est.0c06357] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
There is concern about potential exposure to opportunistic pathogens when reopening buildings closed due to the COVID-19 pandemic. In this study, water samples were collected before, during, and after flushing showers in five unoccupied (i.e., for ∼2 months) university buildings with quantification of opportunists via a cultivation-based assay (Legionella pneumophila only) and quantitative PCR. L. pneumophila were not detected by either method; Legionella spp., nontuberculous mycobacteria (NTM), and Mycobacterium avium complex (MAC), however, were widespread. Using quantitative microbial risk assessment (QMRA), the estimated risks of illness from exposure to L. pneumophila and MAC via showering were generally low (i.e., less than a 10-7 daily risk threshold), with the exception of systemic infection risk from MAC exposure in some buildings. Flushing rapidly restored the total chlorine (as chloramine) residual and decreased bacterial gene targets to building inlet concentrations within 30 min. During the postflush stagnation period, the residual chlorine dissipated within a few days and bacteria rebounded, approaching preflush concentrations after 6-7 days. These results suggest that flushing can quickly improve water quality in unoccupied buildings, but the improvement may only last a few days.
Collapse
Affiliation(s)
- Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Taegyu Kim
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Michael B Waak
- Norwegian University of Science and Technology, Trondheim 7031, Norway
- Department of Infrastructure, SINTEF Community, Trondheim 7031, Norway
| | - Tucker Burch
- Agricultural Research Service, U.S. Department of Agriculture, Marshfield, Wisconsin 54449, United States
| | - Michael McCarty
- School of Public Health, University of Minnesota, Minneapolis 55455, Minnesota, United States
| |
Collapse
|
19
|
Sit bath systems: A new source of Legionella infection. PLoS One 2020; 15:e0241756. [PMID: 33147266 PMCID: PMC7641379 DOI: 10.1371/journal.pone.0241756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 10/21/2020] [Indexed: 11/19/2022] Open
Abstract
Sit Bath Systems (SBSs) are the most common hygiene method for patients who are not self-sufficient. Therefore, the water quality of SBSs in the nosocomial environment plays a fundamental role in controlling infections for both patients and health-care workers. A long-term study on Legionella and Pseudomonas aeruginosa (P. aeruginosa) contamination was performed in SBSs (n = 20) of six Health Care Facilities (HCFs). A total of 254 water samples were analyzed following ISO procedures. The samples were positive for P. aeruginosa (46.85%) and Legionella (53.54%), respectively, both over the directive limits. Legionella isolates were identified as: Legionella pneumophila (L. pneumophila) serogroups 1, 3, and 6 and Legionella non-pneumophila species (L. anisa, L. londiniensis, L. rubrilucens, and L. nagelii). Moreover, the contamination found was studied with respect to median temperature measured (42 °C), from which two groups (A and B) could be distinguished. P. aeruginosa was found in both groups (100% of SBSs), while a higher percentage of Legionella positive samples was found in group A (75% of SBSs), compared to group B (50% of SBSs), showing how Legionella control could be carried out by using temperatures above 42 °C. An analysis of SBS water pipelines, maintenance, and disinfection treatments indicates SBSs as a new source of infection risk for both patients and health-care workers.
Collapse
|
20
|
Interactive Effects of Copper Pipe, Stagnation, Corrosion Control, and Disinfectant Residual Influenced Reduction of Legionella pneumophila during Simulations of the Flint Water Crisis. Pathogens 2020; 9:pathogens9090730. [PMID: 32899686 PMCID: PMC7559348 DOI: 10.3390/pathogens9090730] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 08/28/2020] [Accepted: 08/31/2020] [Indexed: 01/28/2023] Open
Abstract
Flint, MI experienced two outbreaks of Legionnaires' Disease (LD) during the summers of 2014 and 2015, coinciding with use of Flint River as a drinking water source without corrosion control. Using simulated distribution systems (SDSs) followed by stagnant simulated premise (i.e., building) plumbing reactors (SPPRs) containing cross-linked polyethylene (PEX) or copper pipe, we reproduced trends in water chemistry and Legionella proliferation observed in the field when Flint River versus Detroit water were used before, during, and after the outbreak. Specifically, due to high chlorine demand in the SDSs, SPPRs with treated Flint River water were chlorine deficient and had elevated L. pneumophila numbers in the PEX condition. SPPRs with Detroit water, which had lower chlorine demand and higher residual chlorine, lost all culturable L. pneumophila within two months. L. pneumophila also diminished more rapidly with time in Flint River SPPRs with copper pipe, presumably due to the bacteriostatic properties of elevated copper concentrations caused by lack of corrosion control and stagnation. This study confirms hypothesized mechanisms by which the switch in water chemistry, pipe materials, and different flow patterns in Flint premise plumbing may have contributed to observed LD outbreak patterns.
Collapse
|
21
|
Marchesi I, Paduano S, Frezza G, Sircana L, Vecchi E, Zuccarello P, Oliveri Conti G, Ferrante M, Borella P, Bargellini A. Safety and Effectiveness of Monochloramine Treatment for Disinfecting Hospital Water Networks. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17176116. [PMID: 32842654 PMCID: PMC7503937 DOI: 10.3390/ijerph17176116] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 08/12/2020] [Accepted: 08/20/2020] [Indexed: 11/16/2022]
Abstract
The formation of potentially carcinogenic N-nitrosamines, associated with monochloramine, requires further research due to the growing interest in using this biocide for the secondary disinfection of water in public and private buildings. The aim of our study was to evaluate the possible formation of N-nitrosamines and other toxic disinfection by-products (DBPs) in hospital hot water networks treated with monochloramine. The effectiveness of this biocide in controlling Legionella spp. contamination was also verified. For this purpose, four different monochloramine-treated networks, in terms of the duration of treatment and method of biocide injection, were investigated. Untreated hot water, municipal cold water and, limited to N-nitrosamines analysis, hot water treated with chlorine dioxide were analyzed for comparison. Legionella spp. contamination was successfully controlled without any formation of N-nitrosamines. No nitrification or formation of the regulated DBPs, such as chlorites and trihalomethanes, occurred in monochloramine-treated water networks. However, a stable formulation of hypochlorite, its frequent replacement with a fresh product, and the routine monitoring of free ammonia are recommended to ensure a proper disinfection. Our study confirms that monochloramine may be proposed as an effective and safe strategy for the continuous disinfection of building plumbing systems, preventing vulnerable individuals from being exposed to legionellae and dangerous DBPs.
Collapse
Affiliation(s)
- Isabella Marchesi
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Via Campi 287, 41125 Modena, Italy; (S.P.); (G.F.); (P.B.); (A.B.)
- Correspondence: ; Tel.: +39-059-2055460
| | - Stefania Paduano
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Via Campi 287, 41125 Modena, Italy; (S.P.); (G.F.); (P.B.); (A.B.)
| | - Giuseppina Frezza
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Via Campi 287, 41125 Modena, Italy; (S.P.); (G.F.); (P.B.); (A.B.)
| | - Luca Sircana
- University Hospital Policlinico of Modena, Largo del Pozzo 71, 41124 Modena, Italy; (L.S.); (E.V.)
| | - Elena Vecchi
- University Hospital Policlinico of Modena, Largo del Pozzo 71, 41124 Modena, Italy; (L.S.); (E.V.)
| | - Pietro Zuccarello
- Environmental and Food Hygiene Laboratory (LIAA), Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (P.Z.); (G.O.C.); (M.F.)
| | - Gea Oliveri Conti
- Environmental and Food Hygiene Laboratory (LIAA), Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (P.Z.); (G.O.C.); (M.F.)
| | - Margherita Ferrante
- Environmental and Food Hygiene Laboratory (LIAA), Department of Medical and Surgical Sciences and Advanced Technologies “G.F. Ingrassia”, University of Catania, 95123 Catania, Italy; (P.Z.); (G.O.C.); (M.F.)
| | - Paola Borella
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Via Campi 287, 41125 Modena, Italy; (S.P.); (G.F.); (P.B.); (A.B.)
| | - Annalisa Bargellini
- Department of Biomedical, Metabolic and Neural Sciences, Section of Public Health, University of Modena and Reggio Emilia, Via Campi 287, 41125 Modena, Italy; (S.P.); (G.F.); (P.B.); (A.B.)
| |
Collapse
|
22
|
Julien R, Dreelin E, Whelton AJ, Lee J, Aw TG, Dean K, Mitchell J. Knowledge gaps and risks associated with premise plumbing drinking water quality. ACTA ACUST UNITED AC 2020. [DOI: 10.1002/aws2.1177] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Affiliation(s)
- Ryan Julien
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| | - Erin Dreelin
- Department of Fisheries and WildlifeMichigan State University East Lansing Michigan
| | - Andrew J. Whelton
- Lyles School of Civil Engineering and Environmental and Ecological EngineeringPurdue University West Lafayette Indiana
| | - Juneseok Lee
- Department of Civil and Environmental EngineeringManhattan College Riverdale New York
| | - Tiong Gim Aw
- Department of Environmental Health Sciences, School of Public Health and Tropical MedicineTulane University New Orleans Louisiana
| | - Kara Dean
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| | - Jade Mitchell
- Department of Biosystems and Agricultural EngineeringMichigan State University East Lansing Michigan
| |
Collapse
|
23
|
Abstract
Nitrification is a major issue that utilities must address if they utilize chloramines as a secondary disinfectant. Nitrification is the oxidation of free ammonia to nitrite which is then further oxidized to nitrate. Free ammonia is found in drinking water systems as a result of overfeeding at the water treatment plant (WTP) or as a result of the decomposition of monochloramine. Premise plumbing systems (i.e., the plumbing systems within buildings and homes) are characterized by irregular usage patterns, high water age, high temperature, and high surface-to-volume ratios. These characteristics create ideal conditions for increased chloramine decay, bacterial growth, and nitrification. This review discusses factors within premise plumbing that are likely to influence nitrification, and vice versa. Factors influencing, or influenced by, nitrification include the rate at which chloramine residual decays, microbial regrowth, corrosion of pipe materials, and water conservation practices. From a regulatory standpoint, the greatest impact of nitrification within premise plumbing is likely to be a result of increased lead levels during Lead and Copper Rule (LCR) sampling. Other drinking water regulations related to nitrifying parameters are monitored in a manner to reduce premise plumbing impacts. One way to potentially control nitrification in premise plumbing systems is through the development of building management plans.
Collapse
|
24
|
Impact of Chlorine and Chloramine on the Detection and Quantification of Legionella pneumophila and Mycobacterium Species. Appl Environ Microbiol 2019; 85:AEM.01942-19. [PMID: 31604766 DOI: 10.1128/aem.01942-19] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 10/03/2019] [Indexed: 12/13/2022] Open
Abstract
Potable water can be a source of transmission for legionellosis and nontuberculous mycobacterium (NTM) infections and diseases. Legionellosis is caused largely by Legionella pneumophila, specifically serogroup 1 (Sg1). Mycobacterium avium, Mycobacterium intracellulare, and Mycobacterium abscessus are three leading species associated with pulmonary NTM disease. The estimated rates of these diseases are increasing in the United States, and the cost of treatment is high. Therefore, a national assessment of water disinfection efficacy for these pathogens was needed. The disinfectant type and total chlorine residual (TClR) were investigated to understand their influence on the detection and concentrations of the five pathogens in potable water. Samples (n = 358) were collected from point-of-use taps (cold or hot) from locations across the United States served by public water utilities that disinfected with chlorine or chloramine. The bacteria were detected and quantified using specific primer and probe quantitative-PCR (qPCR) methods. The total chlorine residual was measured spectrophotometrically. Chlorine was the more potent disinfectant for controlling the three mycobacterial species. Chloramine was effective at controlling L. pneumophila and Sg1. Plotting the TClR associated with positive microbial detection showed that an upward TClR adjustment could reduce the bacterial count in chlorinated water but was not as effective for chloramine. Each species of bacteria responded differently to the disinfection type, concentration, and temperature. There was no unifying condition among the water characteristics studied that achieved microbial control for all. This information will help guide disinfectant decisions aimed at reducing occurrences of these pathogens at consumer taps and as related to the disinfectant type and TClR.IMPORTANCE The primary purpose of tap water disinfection is to control the presence of microbes. This study evaluated the role of disinfectant choice on the presence at the tap of L. pneumophila, its Sg1 serogroup, and three species of mycobacteria in tap water samples collected at points of human exposure at locations across the United States. The study demonstrates that microbial survival varies based on the microbial species, disinfectant, and TClR.
Collapse
|
25
|
Detection of pathogenic bacteria in hot tap water using the qPCR method: preliminary research. SN APPLIED SCIENCES 2019. [DOI: 10.1007/s42452-019-0533-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
26
|
LeChevallier MW. Occurrence of culturable
Legionella pneumophila
in drinking water distribution systems. ACTA ACUST UNITED AC 2019. [DOI: 10.1002/aws2.1139] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
27
|
Donohue MJ, King D, Pfaller S, Mistry JH. The sporadic nature of Legionella pneumophila, Legionella pneumophila Sg1 and Mycobacterium avium occurrence within residences and office buildings across 36 states in the United States. J Appl Microbiol 2019; 126:1568-1579. [PMID: 30891905 PMCID: PMC6850209 DOI: 10.1111/jam.14196] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 12/19/2018] [Accepted: 12/21/2018] [Indexed: 12/20/2022]
Abstract
Aim Premise plumbing may disseminate the bacteria Legionella pneumophila and Mycobacterium avium, the causative agents for legionellosis and pulmonary nontuberculous mycobacterium disease respectively. Methods and Results Using quantitative PCR, the occurrence and persistence of L. pneumophila, L. pneumophila serogroup (Sg)1 and M. avium were evaluated in drinking water samples from 108 cold water taps (residences: n = 43) and (office buildings: n = 65). Mycobacterium avium, L. pneumophila and L. pneumophila Sg1 were detected 45, 41 and 25% of all structures respectively. Two occurrence patterns were evaluated: sporadic (a single detection from the three samplings) and persistent (detections in two or more of the three samples). Conclusions The micro‐organism's occurrence was largely sporadic. Office buildings were prone to microbial persistence independent of building age and square footage. Microbial persistence at residences was observed in those older than 40 years for L. pneumophila and was rarely observed for M. avium. The microbial occurrence was evenly distributed between structure types but there were differences in density and persistence. Significance of and Impact of the Study The study is important because residences are often suspected to be the source when a case of disease is reported. These data demonstrate that this may not be the case for a sporadic incidence.
Collapse
Affiliation(s)
- M J Donohue
- National Exposure Research Laboratory, United States Environmental Protection Agency, Cincinnati, OH, USA
| | - D King
- National Exposure Research Laboratory, United States Environmental Protection Agency, Cincinnati, OH, USA
| | - S Pfaller
- National Exposure Research Laboratory, United States Environmental Protection Agency, Cincinnati, OH, USA
| | - J H Mistry
- Region 6, United States Environmental Protection Agency, Dallas, TX, USA
| |
Collapse
|
28
|
LeChevallier MW. Monitoring distribution systems for
Legionella pneumophila
using Legiolert. ACTA ACUST UNITED AC 2019. [DOI: 10.1002/aws2.1122] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
29
|
Waak MB, LaPara TM, Hallé C, Hozalski RM. Occurrence of Legionella spp. in Water-Main Biofilms from Two Drinking Water Distribution Systems. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:7630-7639. [PMID: 29902377 DOI: 10.1021/acs.est.8b01170] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The maintenance of a chlorine or chloramine residual to suppress waterborne pathogens in drinking water distribution systems is common practice in the United States but less common in Europe. In this study, we investigated the occurrence of Bacteria and Legionella spp. in water-main biofilms and tap water from a chloraminated distribution system in the United States and a system in Norway with no residual using real-time quantitative polymerase chain reaction (qPCR). Despite generally higher temperatures and assimilable organic carbon levels in the chloraminated system, total Bacteria and Legionella spp. were significantly lower in water-main biofilms and tap water of that system ( p < 0.05). Legionella spp. were not detected in the biofilms of the chloraminated system (0 of 35 samples) but were frequently detected in biofilms from the no-residual system (10 of 23 samples; maximum concentration = 7.8 × 104 gene copies cm-2). This investigation suggests water-main biofilms may serve as a source of Legionella for tap water and premise plumbing systems, and residual chloramine may aid in reducing their abundance.
Collapse
Affiliation(s)
- Michael B Waak
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Drive Southeast , Minneapolis , Minnesota 55455 , United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Drive Southeast , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Avenue , Saint Paul , Minnesota 55108 , United States
| | - Cynthia Hallé
- Department of Civil and Environmental Engineering , Norwegian University of Science and Technology , S.P. Andersens veg 5 , Trondheim NO-7491 , Norway
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Drive Southeast , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Avenue , Saint Paul , Minnesota 55108 , United States
| |
Collapse
|
30
|
Li H, Li S, Tang W, Yang Y, Zhao J, Xia S, Zhang W, Wang H. Influence of secondary water supply systems on microbial community structure and opportunistic pathogen gene markers. WATER RESEARCH 2018; 136:160-168. [PMID: 29501760 DOI: 10.1016/j.watres.2018.02.031] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Revised: 02/10/2018] [Accepted: 02/12/2018] [Indexed: 06/08/2023]
Abstract
Secondary water supply systems (SWSSs) refer to the in-building infrastructures (e.g., water storage tanks) used to supply water pressure beyond the main distribution systems. The purpose of this study was to investigate the influence of SWSSs on microbial community structure and the occurrence of opportunistic pathogens, the latter of which are an emerging public health concern. Higher numbers of bacterial 16S rRNA genes, Legionella and mycobacterial gene markers were found in public building taps served by SWSSs relative to the mains, regardless of the flushing practice (P < 0.05). In residential buildings, genes of L. pneumomhila, Acanthamoeba and Vermamoeba vermiformis were primarily detected in tanks and taps compared to the mains. Long water retention time, warm temperature and loss of disinfectant residuals promoted microbial growth and colonization of potential pathogens in SWSSs. Varied levels of microbial community shifts were found in different types of SWSSs during water transportation from the distribution main to taps, highlighting the critical role of SWSSs in shaping the drinking water microbiota. Overall, the results provided insight to factors that might aid in controlling pathogen proliferation in real-world water systems using SWSSs.
Collapse
Affiliation(s)
- Huan Li
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Shang Li
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Wei Tang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yang Yang
- Department of Thoracic Surgery, Tongji University Shanghai Pulmonary Hospital, Shanghai 200433, China
| | - Jianfu Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Weixian Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
31
|
Presence of Legionella spp. in Hot Water Networks of Different Italian Residential Buildings: A Three-Year Survey. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2017; 14:ijerph14111296. [PMID: 29072607 PMCID: PMC5707935 DOI: 10.3390/ijerph14111296] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Revised: 10/23/2017] [Accepted: 10/23/2017] [Indexed: 11/22/2022]
Abstract
Although the European reports highlight an increase in community-acquired Legionnaires’ disease cases, the risk of Legionella spp. in private houses is underestimated. In Pisa (Italy) we performed a three-year survey on Legionella presence in 121 buildings with an independent hot water production (IB); 64 buildings with a central hot water production (CB); and 35 buildings with a solar thermal system for hot water production (TB). From all the 220 buildings Legionella spp. was researched in two hot water samples collected either at the recirculation point or on the first floor and on the last floor, while the potable water quality was analysed in three cold water samples collected at the inlet from the aqueduct network, at the exit from the autoclave, and at the most remote tap. Legionella pneumophila sg1, Legionella pneumophila sg2–16, and non-pneumophila Legionella species were detected in 26% of the hot water networks, mostly in CB and TB. In these buildings we detected correlations between the presence of Legionella and the total chlorine concentration decrease and/or the increase of the temperature. Cold water resulted free from microbiological hazards, with the exception of Serratia liquefaciens and Enterobacter cloacae isolated at the exit from two different autoclaves. We observed an increase in total microbial counts at 22 °C and 37 °C between the samples collected at the most remote taps compared to the ones collected at the inlet from the aqueduct. The study highlights a condition of potential risk for susceptible categories of population and supports the need for measures of risk assessment and control.
Collapse
|
32
|
Prussin AJ, Schwake DO, Marr LC. Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment. BUILDING AND ENVIRONMENT 2017; 123:684-695. [PMID: 29104349 PMCID: PMC5665586 DOI: 10.1016/j.buildenv.2017.06.024] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Legionella is a genus of pathogenic Gram-negative bacteria responsible for a serious disease known as legionellosis, which is transmitted via inhalation of this pathogen in aerosol form. There are two forms of legionellosis: Legionnaires' disease, which causes pneumonia-like symptoms, and Pontiac fever, which causes influenza-like symptoms. Legionella can be aerosolized from various water sources in the built environment including showers, faucets, hot tubs/swimming pools, cooling towers, and fountains. Incidence of the disease is higher in the summertime, possibly because of increased use of cooling towers for air conditioning systems and differences in water chemistry when outdoor temperatures are higher. Although there have been decades of research related to Legionella transmission, many knowledge gaps remain. While conventional wisdom suggests that showering is an important source of exposure in buildings, existing measurements do not provide strong support for this idea. There has been limited research on the potential for Legionella transmission through heating, ventilation, and air conditioning (HVAC) systems. Epidemiological data suggest a large proportion of legionellosis cases go unreported, as most people who are infected do not seek medical attention. Additionally, controlled laboratory studies examining water-to-air transfer and source tracking are still needed. Herein, we discuss ten questions that spotlight current knowledge about Legionella transmission in the built environment, engineering controls that might prevent future disease outbreaks, and future research that is needed to advance understanding of transmission and control of legionellosis.
Collapse
Affiliation(s)
- Aaron J. Prussin
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
- Corresponding Author:
| | - David Otto Schwake
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Linsey C. Marr
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
33
|
Rhoads WJ, Pruden A, Edwards MA. Interactive Effects of Corrosion, Copper, and Chloramines on Legionella and Mycobacteria in Hot Water Plumbing. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:7065-7075. [PMID: 28513143 DOI: 10.1021/acs.est.6b05616] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Complexities associated with drinking water plumbing systems can result in undesirable interactions among plumbing components that undermine engineering controls for opportunistic pathogens (OPs). In this study, we examine the effects of plumbing system materials and two commonly applied disinfectants, copper and chloramines, on water chemistry and the growth of Legionella and mycobacteria across a transect of bench- and pilot-scale hot water experiments carried out with the same municipal water supply. We discovered that copper released from corrosion of plumbing materials can initiate evolution of >1100 times more hydrogen (H2) from water heater sacrificial anode rods than does presence of copper dosed as soluble cupric ions. H2 is a favorable electron donor for autotrophs and causes fixation of organic carbon that could serve as a nutrient for OPs. Dosed cupric ions acted as a disinfectant in stratified stagnant pipes, inhibiting culturable Legionella and biofilm formation, but promoted Legionella growth in pipes subject to convective mixing. This difference was presumably due to continuous delivery of nutrients to biofilm on the pipes under convective mixing conditions. Chloramines eliminated culturable Legionella and prevented L. pneumophila from recolonizing biofilms, but M. avium gene numbers increased by 0.14-0.76 logs in the bulk water and were unaffected in the biofilm. This study provides practical confirmation of past discrepancies in the literature regarding the variable effects of copper on Legionella growth, and confirms prior reports of trade-offs between Legionella and mycobacteria if chloramines are applied as secondary disinfectant residual.
Collapse
Affiliation(s)
- William J Rhoads
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| | - Marc A Edwards
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University , 418 Durham Hall, Blacksburg, Virginia 24061, United States
| |
Collapse
|
34
|
Wang H, Bédard E, Prévost M, Camper AK, Hill VR, Pruden A. Methodological approaches for monitoring opportunistic pathogens in premise plumbing: A review. WATER RESEARCH 2017; 117:68-86. [PMID: 28390237 PMCID: PMC5693313 DOI: 10.1016/j.watres.2017.03.046] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 03/19/2017] [Accepted: 03/22/2017] [Indexed: 05/06/2023]
Abstract
Opportunistic premise (i.e., building) plumbing pathogens (OPPPs, e.g., Legionella pneumophila, Mycobacterium avium complex, Pseudomonas aeruginosa, Acanthamoeba, and Naegleria fowleri) are a significant and growing source of disease. Because OPPPs establish and grow as part of the native drinking water microbiota, they do not correspond to fecal indicators, presenting a major challenge to standard drinking water monitoring practices. Further, different OPPPs present distinct requirements for sampling, preservation, and analysis, creating an impediment to their parallel detection. The aim of this critical review is to evaluate the state of the science of monitoring OPPPs and identify a path forward for their parallel detection and quantification in a manner commensurate with the need for reliable data that is informative to risk assessment and mitigation. Water and biofilm sampling procedures, as well as factors influencing sample representativeness and detection sensitivity, are critically evaluated with respect to the five representative bacterial and amoebal OPPPs noted above. Available culturing and molecular approaches are discussed in terms of their advantages, limitations, and applicability. Knowledge gaps and research needs towards standardized approaches are identified.
Collapse
Affiliation(s)
- Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
| | - Emilie Bédard
- Department of Civil Engineering, Polytechnique Montreal, Montreal, QC, Canada
| | - Michèle Prévost
- Department of Civil Engineering, Polytechnique Montreal, Montreal, QC, Canada
| | - Anne K Camper
- Center for Biofilm Engineering and Department of Civil Engineering, Montana State University, Bozeman, MT 59717, USA
| | - Vincent R Hill
- Waterborne Disease Prevention Branch, Centers for Disease Control and Prevention, 1600 Clifton Road NE, Atlanta, GA 30329, USA
| | - Amy Pruden
- Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| |
Collapse
|
35
|
Hull NM, Holinger EP, Ross KA, Robertson CE, Harris JK, Stevens MJ, Pace NR. Longitudinal and Source-to-Tap New Orleans, LA, U.S.A. Drinking Water Microbiology. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:4220-4229. [PMID: 28296394 DOI: 10.1021/acs.est.6b06064] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The two municipal drinking water systems of New Orleans, LA, U.S.A. were sampled to compare the microbiology of independent systems that treat the same surface water from the Mississippi River. To better understand temporal trends and sources of microbiology delivered to taps, these treatment plants and distribution systems were subjected to source-to-tap sampling over four years. Both plants employ traditional treatment by chloramination, applied during or after settling, followed by filtration before distribution in a warm, low water age system. Longitudinal samples indicated microbiology to have stability both spatially and temporally, and between treatment plants and distribution systems. Disinfection had the greatest impact on microbial composition, which was further refined by filtration and influenced by distribution and premise plumbing. Actinobacteria spp. exhibited trends with treatment. In particular, Mycobacterium spp., very low in finished waters, occurred idiosyncratically at high levels in some tap waters, indicating distribution and/or premise plumbing as main contributors of mycobacteria. Legionella spp., another genus containing potential opportunistic pathogens, also occurred ubiquitously. Source water microbiology was most divergent from tap water, and each step of treatment brought samples more closely similar to tap waters.
Collapse
Affiliation(s)
- Natalie M Hull
- Department of Civil, Environmental, and Architectural Engineering, University of Colorado , Boulder, Colorado 80309, United States
| | - Eric P Holinger
- Department of Molecular, Cellular, and Developmental Biology, University of Colorado , Boulder, Colorado 80309, United States
| | - Kimberly A Ross
- Department of Molecular, Cellular, and Developmental Biology, University of Colorado , Boulder, Colorado 80309, United States
| | - Charles E Robertson
- Division of Infectious Disease, University of Colorado School of Medicine , Anschutz Campus, Aurora, Colorado 80045, United States
| | - J Kirk Harris
- Department of Pediatrics, University of Colorado School of Medicine , Anschutz Campus, Aurora, Colorado 80045, United States
| | - Mark J Stevens
- Department of Pediatrics, University of Colorado School of Medicine , Anschutz Campus, Aurora, Colorado 80045, United States
| | - Norman R Pace
- Department of Molecular, Cellular, and Developmental Biology, University of Colorado , Boulder, Colorado 80309, United States
| |
Collapse
|
36
|
Springston JP, Yocavitch L. Existence and control of Legionella bacteria in building water systems: A review. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2017; 14:124-134. [PMID: 27624495 DOI: 10.1080/15459624.2016.1229481] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Legionellae are waterborne bacteria which are capable of causing potentially fatal Legionnaires' disease (LD), as well as Pontiac Fever. Public concern about Legionella exploded following the 1976 outbreak at the American Legion conference in Philadelphia, where 221 attendees contracted pneumonia and 34 died. Since that time, a variety of different control methods and strategies have been developed and implemented in an effort to eradicate Legionella from building water systems. Despite these efforts, the incidence of LD has been steadily increasing in the U.S. for more than a decade. Public health and occupational hygiene professionals have maintained an active debate regarding best practices for management and control of Legionella. Professional opinion remains divided with respect to the relative merits of performing routine sampling for Legionella, vs. the passive, reactive approach that has been largely embraced by public health officials and facility owners. Given the potential risks and ramifications associated with waiting to assess systems for Legionella until after disease has been identified and confirmed, a proactive approach of periodic testing for Legionella, along with proper water treatment, is the best approach to avoiding large-scale disease outbreaks.
Collapse
|
37
|
King DN, Donohue MJ, Vesper SJ, Villegas EN, Ware MW, Vogel ME, Furlong EF, Kolpin DW, Glassmeyer ST, Pfaller S. Microbial pathogens in source and treated waters from drinking water treatment plants in the United States and implications for human health. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 562:987-995. [PMID: 27260619 DOI: 10.1016/j.scitotenv.2016.03.214] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 03/29/2016] [Accepted: 03/29/2016] [Indexed: 06/05/2023]
Abstract
An occurrence survey was conducted on selected pathogens in source and treated drinking water collected from 25 drinking water treatment plants (DWTPs) in the United States. Water samples were analyzed for the protozoa Giardia and Cryptosporidium (EPA Method 1623); the fungi Aspergillus fumigatus, Aspergillus niger and Aspergillus terreus (quantitative PCR [qPCR]); and the bacteria Legionella pneumophila (qPCR), Mycobacterium avium, M. avium subspecies paratuberculosis, and Mycobacterium intracellulare (qPCR and culture). Cryptosporidium and Giardia were detected in 25% and in 46% of the source water samples, respectively (treated waters were not tested). Aspergillus fumigatus was the most commonly detected fungus in source waters (48%) but none of the three fungi were detected in treated water. Legionella pneumophila was detected in 25% of the source water samples but in only 4% of treated water samples. M. avium and M. intracellulare were both detected in 25% of source water, while all three mycobacteria were detected in 36% of treated water samples. Five species of mycobacteria, Mycobacterium mucogenicum, Mycobacterium phocaicum, Mycobacterium triplex, Mycobacterium fortuitum, and Mycobacterium lentiflavum were cultured from treated water samples. Although these DWTPs represent a fraction of those in the U.S., the results suggest that many of these pathogens are widespread in source waters but that treatment is generally effective in reducing them to below detection limits. The one exception is the mycobacteria, which were commonly detected in treated water, even when not detected in source waters.
Collapse
Affiliation(s)
- Dawn N King
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Maura J Donohue
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Stephen J Vesper
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Eric N Villegas
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Michael W Ware
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Megan E Vogel
- Department of Internal Medicine, University of Cincinnati, College of Medicine, 231 Albert Sabin Way, Cincinnati, OH 45229, United States
| | - Edward F Furlong
- U.S. Geological Survey, Denver Federal Center, P.O. Box 25585, Denver, CO 80225, United States
| | - Dana W Kolpin
- U.S. Geological Survey, 400 S. Clinton Street, Iowa City, IA 52240, United States
| | - Susan T Glassmeyer
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States
| | - Stacy Pfaller
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency, 26 West Martin Luther King Dr., Cincinnati, OH 45268, United States.
| |
Collapse
|
38
|
Rhoads WJ, Pruden A, Edwards MA. Convective Mixing in Distal Pipes Exacerbates Legionella pneumophila Growth in Hot Water Plumbing. Pathogens 2016; 5:E29. [PMID: 26985908 PMCID: PMC4810150 DOI: 10.3390/pathogens5010029] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 02/15/2016] [Accepted: 03/01/2016] [Indexed: 11/17/2022] Open
Abstract
Legionella pneumophila is known to proliferate in hot water plumbing systems, but little is known about the specific physicochemical factors that contribute to its regrowth. Here, L. pneumophila trends were examined in controlled, replicated pilot-scale hot water systems with continuous recirculation lines subject to two water heater settings (40 °C and 58 °C) and three distal tap water use frequencies (high, medium, and low) with two pipe configurations (oriented upward to promote convective mixing with the recirculating line and downward to prevent it). Water heater temperature setting determined where L. pneumophila regrowth occurred in each system, with an increase of up to 4.4 log gene copies/mL in the 40 °C system tank and recirculating line relative to influent water compared to only 2.5 log gene copies/mL regrowth in the 58 °C system. Distal pipes without convective mixing cooled to room temperature (23-24 °C) during periods of no water use, but pipes with convective mixing equilibrated to 30.5 °C in the 40 °C system and 38.8 °C in the 58 °C system. Corresponding with known temperature effects on L. pneumophila growth and enhanced delivery of nutrients, distal pipes with convective mixing had on average 0.2 log more gene copies/mL in the 40 °C system and 0.8 log more gene copies/mL in the 58 °C system. Importantly, this work demonstrated the potential for thermal control strategies to be undermined by distal taps in general, and convective mixing in particular.
Collapse
Affiliation(s)
- William J Rhoads
- Via Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 401 Durham Hall, Blacksburg, VA 24061, USA.
| | - Amy Pruden
- Via Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 401 Durham Hall, Blacksburg, VA 24061, USA.
| | - Marc A Edwards
- Via Department of Civil and Environmental Engineering, Virginia Tech, 1145 Perry St., 401 Durham Hall, Blacksburg, VA 24061, USA.
| |
Collapse
|
39
|
Rhoads WJ, Ji P, Pruden A, Edwards MA. Water heater temperature set point and water use patterns influence Legionella pneumophila and associated microorganisms at the tap. MICROBIOME 2015; 3:67. [PMID: 26627188 PMCID: PMC4666224 DOI: 10.1186/s40168-015-0134-1] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Accepted: 11/17/2015] [Indexed: 05/22/2023]
Abstract
BACKGROUND Lowering water heater temperature set points and using less drinking water are common approaches to conserving water and energy; yet, there are discrepancies in past literature regarding the effects of water heater temperature and water use patterns on the occurrence of opportunistic pathogens, in particular Legionella pneumophila. Our objective was to conduct a controlled, replicated pilot-scale investigation to address this knowledge gap using continuously recirculating water heaters to examine five water heater set points (39-58 °C) under three water use conditions. We hypothesized that L. pneumophila levels at the tap depend on the collective influence of water heater temperature, flow frequency, and the resident plumbing ecology. RESULTS We confirmed temperature setting to be a critical factor in suppressing L. pneumophila growth both in continuously recirculating hot water lines and at distal taps. For example, at 51 °C, planktonic L. pneumophila in recirculating lines was reduced by a factor of 28.7 compared to 39 °C and was prevented from re-colonizing biofilm. However, L. pneumophila still persisted up to 58 °C, with evidence that it was growing under the conditions of this study. Further, exposure to 51 °C water in a low-use tap appeared to optimally select for L. pneumophila (e.g., 125 times greater numbers than in high-use taps). We subsequently explored relationships among L. pneumophila and other ecologically relevant microbes, noting that elevated temperature did not have a general disinfecting effect in terms of total bacterial numbers. We documented the relationship between L. pneumophila and Legionella spp., and noted several instances of correlations with Vermamoeba vermiformis, and generally found that there is a dynamic relationship with this amoeba host over the range of temperatures and water use frequencies examined. CONCLUSIONS Our study provides a new window of understanding into the microbial ecology of potable hot water systems and helps to resolve past discrepancies in the literature regarding the influence of water temperature and stagnation on L. pneumophila, which is the cause of a growing number of outbreaks. This work is especially timely, given society's movement towards "green" buildings and the need to reconcile innovations in building design with public health.
Collapse
Affiliation(s)
- William J Rhoads
- Charles E. Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
| | - Pan Ji
- Charles E. Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Amy Pruden
- Charles E. Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Marc A Edwards
- Charles E. Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| |
Collapse
|
40
|
Wang H, Masters S, Falkinham JO, Edwards MA, Pruden A. Distribution System Water Quality Affects Responses of Opportunistic Pathogen Gene Markers in Household Water Heaters. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2015; 49:8416-24. [PMID: 26121595 DOI: 10.1021/acs.est.5b01538] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Illustrative distribution system operation and management practices shaped the occurrence and persistence of Legionella spp., nontuberculous mycobacteria (NTM), Pseudomonas aeruginosa, and two amoebae host (Acanthamoeba spp., Vermamoeba vermiformis) gene markers in the effluent of standardized simulated household water heaters (SWHs). The interplay between disinfectant type (chlorine or chloramine), water age (2.3-5.7 days) and materials (polyvinyl chloride (PVC), cement or iron) in upstream simulated distribution systems (SDSs) profoundly influenced levels of pathogen gene markers in corresponding SWH bulk waters. For example, Legionella spp. were 3-4 log higher in SWHs receiving water from chloraminated vs chlorinated SDSs, because of disinfectant decay from nitrification. By contrast, SWHs fed with chlorinated PVC SDS water not only harbored the lowest levels of all pathogen markers, but effluent from the chlorinated SWHs were even lower than influent levels in several instances (e.g., 2 log less Legionella spp. and NTM for PVC and 3-5 log less P. aeruginosa for cement). However, pathogen gene marker influent levels correlated positively to effluent levels in the SWHs (P < 0.05). Likewise, microbial community structures were similar between SWHs and the corresponding SDS feed waters. This study highlights the importance and challenges of distribution system management/operation to help control opportunistic pathogens.
Collapse
Affiliation(s)
- Hong Wang
- †State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Sheldon Masters
- ‡Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061, United States
| | - Joseph O Falkinham
- §Department of Biological Sciences, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061, United States
| | - Marc A Edwards
- ‡Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061, United States
| | - Amy Pruden
- ‡Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061, United States
| |
Collapse
|
41
|
Sánchez-Busó L, Olmos MP, Camaró ML, Adrián F, Calafat JM, González-Candelas F. Phylogenetic analysis of environmental Legionella pneumophila isolates from an endemic area (Alcoy, Spain). INFECTION GENETICS AND EVOLUTION 2015; 30:45-54. [DOI: 10.1016/j.meegid.2014.12.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2014] [Revised: 12/02/2014] [Accepted: 12/06/2014] [Indexed: 12/20/2022]
|
42
|
Wang H, Proctor CR, Edwards MA, Pryor M, Santo Domingo JW, Ryu H, Camper AK, Olson A, Pruden A. Microbial community response to chlorine conversion in a chloraminated drinking water distribution system. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:10624-10633. [PMID: 25118569 DOI: 10.1021/es502646d] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Temporary conversion to chlorine (i.e., "chlorine burn") is a common approach to controlling nitrification in chloraminated drinking water distribution systems, yet its effectiveness and mode(s) of action are not fully understood. This study characterized occurrence of nitrifying populations before, during and after a chlorine burn at 46 sites in a chloraminated distribution system with varying pipe materials and levels of observed nitrification. Quantitative polymerase chain reaction analysis of gene markers present in nitrifying populations indicated higher frequency of detection of ammonia oxidizing bacteria (AOB) (72% of samples) relative to ammonia oxidizing archaea (AOA) (28% of samples). Nitrospira nitrite oxidizing bacteria (NOB) were detected at 45% of samples, while presence of Nitrobacter NOB could not be confirmed at any of the samples. During the chlorine burn, the numbers of AOA, AOB, and Nitrospira greatly reduced (i.e., 0.8-2.4 log). However, rapid and continued regrowth of AOB and Nitrospira were observed along with nitrite production in the bulk water within four months after the chlorine burn, and nitrification outbreaks appeared to worsen 6-12 months later, even after adopting a twice annual burn program. Although high throughput sequencing of 16S rRNA genes revealed a distinct community shift and higher diversity index during the chlorine burn, it steadily returned towards a condition more similar to pre-burn than burn stage. Significant factors associated with nitrifier and microbial community composition included water age and sampling location type, but not pipe material. Overall, these results indicate that there is limited long-term effect of chlorine burns on nitrifying populations and the broader microbial community.
Collapse
Affiliation(s)
- Hong Wang
- Via Department of Civil and Environmental Engineering, Virginia Tech , Blacksburg, Virginia 24061, United States
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Community outbreak of legionellosis and an environmental investigation into a community water system. Epidemiol Infect 2014; 143:1322-31. [PMID: 25083716 DOI: 10.1017/s0950268814001964] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
During two legionellosis outbreak investigations, one at a geriatric centre and the other in high-rise housing for seniors, it was observed that additional cases of legionellosis occurred in nearby smaller residential settings. This apparent geographical cluster of legionellosis occurred in the same general area of a community water storage tank. No potential airborne sources in or near the area could be identified, but a community water system storage tank that was centrally located among case residences spurred an investigation of water-quality factors in the identified investigation area. Conditions conducive for Legionella growth, particularly low chlorine residuals, were found. The rate of legionellosis among residents aged ⩾50 years in the investigation areas (61·0 and 64·1/100 000) was eight times higher than in the rest of the service area (9·0/100 000) and almost 20 times higher than the statewide annual average incidence rate (3·2/100 000). A water mains flushing programme in the area was launched by the water utility, and water samples taken before and during flushing found L. pneumophila.
Collapse
|
44
|
Donohue MJ, O'Connell K, Vesper SJ, Mistry JH, King D, Kostich M, Pfaller S. Widespread molecular detection of Legionella pneumophila Serogroup 1 in cold water taps across the United States. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:3145-3152. [PMID: 24548208 DOI: 10.1021/es4055115] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
In the United States, 6,868 cases of legionellosis were reported to the Center for Disease Control and Prevention in 2009-2010. Of these reports, it is estimated that 84% are caused by the microorganism Legionella pneumophila Serogroup (Sg) 1. Legionella spp. have been isolated and recovered from a variety of natural freshwater environments. Human exposure to L. pneumophila Sg1 may occur from aerosolization and subsequent inhalation of household and facility water. In this study, two primer/probe sets (one able to detect L. pneumophila and the other L. pneumophila Sg1) were determined to be highly sensitive and selective for their respective targets. Over 272 water samples, collected in 2009 and 2010 from 68 public and private water taps across the United States, were analyzed using the two qPCR assays to evaluate the incidence of L. pneumophila Sg1. Nearly half of the taps showed the presence of L. pneumophila Sg1 in one sampling event, and 16% of taps were positive in more than one sampling event. This study is the first United States survey to document the occurrence and colonization of L. pneumophila Sg1 in cold water delivered from point of use taps.
Collapse
Affiliation(s)
- Maura J Donohue
- Office of Research and Development, National Exposure Research Laboratory, United States Environmental Protection Agency , 26 West Martin Luther King Drive, Mail Stop 593, Cincinnati, Ohio 45268, United States
| | | | | | | | | | | | | |
Collapse
|
45
|
Buse HY, Lu J, Lu X, Mou X, Ashbolt NJ. Microbial diversities (16S and 18S rRNA gene pyrosequencing) and environmental pathogens within drinking water biofilms grown on the common premise plumbing materials unplasticized polyvinylchloride and copper. FEMS Microbiol Ecol 2014; 88:280-95. [PMID: 24490699 DOI: 10.1111/1574-6941.12294] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2013] [Revised: 01/08/2014] [Accepted: 01/23/2014] [Indexed: 11/29/2022] Open
Abstract
Drinking water (DW) biofilm communities influence the survival of opportunistic pathogens, yet knowledge about the microbial composition of DW biofilms developed on common in-premise plumbing material is limited. Utilizing 16S and 18S rRNA gene pyrosequencing, this study characterized the microbial community structure within DW biofilms established on unplasticized polyvinyl chloride (uPVC) and copper (Cu) surfaces and the impact of introducing Legionella pneumophila (Lp) and Acanthamoeba polyphaga. Mature (> 1 year old) biofilms were developed before inoculation with sterilized DW (control, Con), Lp, or Lp and A. polyphaga (LpAp). Comparison of uPVC and Cu biofilms indicated significant differences between bacterial (P = 0.001) and eukaryotic (P < 0.01) members attributable to the unique presence of several family taxa: Burkholderiaceae, Characeae, Epistylidae, Goniomonadaceae, Paramoebidae, Plasmodiophoridae, Plectidae, Sphenomonadidae, and Toxariaceae within uPVC biofilms; and Enterobacteriaceae, Erythrobacteraceae, Methylophilaceae, Acanthamoebidae, and Chlamydomonadaceae within Cu biofilms. Introduction of Lp alone or with A. polyphaga had no effect on bacterial community profiles (P > 0.05) but did affect eukaryotic members (uPVC, P < 0.01; Cu, P = 0.001). Thus, established DW biofilms host complex communities that may vary based on substratum matrix and maintain consistent bacterial communities despite introduction of Lp, an environmental pathogen.
Collapse
|
46
|
|
47
|
Wang H, Masters S, Edwards MA, Falkinham JO, Pruden A. Effect of disinfectant, water age, and pipe materials on bacterial and eukaryotic community structure in drinking water biofilm. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2014; 48:1426-35. [PMID: 24401122 DOI: 10.1021/es402636u] [Citation(s) in RCA: 129] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Availability of safe, pathogen-free drinking water is vital to public health; however, it is impossible to deliver sterile drinking water to consumers. Recent microbiome research is bringing new understanding to the true extent and diversity of microbes that inhabit water distribution systems. The purpose of this study was to determine how water chemistry in main distribution lines shape the microbiome in drinking water biofilms and to explore potential associations between opportunistic pathogens and indigenous drinking water microbes. Effects of disinfectant (chloramines, chlorine), water age (2.3 days, 5.7 days), and pipe material (cement, iron, PVC) were compared in parallel triplicate simulated water distribution systems. Pyrosequencing was employed to characterize bacteria and terminal restriction fragment polymorphism was used to profile both bacteria and eukaryotes inhabiting pipe biofilms. Disinfectant and water age were both observed to be strong factors in shaping bacterial and eukaryotic community structures. Pipe material only influenced the bacterial community structure (ANOSIM test, P < 0.05). Interactive effects of disinfectant, pipe material, and water age on both bacteria and eukaryotes were noted. Disinfectant concentration had the strongest effect on bacteria, while dissolved oxygen appeared to be a major driver for eukaryotes (BEST test). Several correlations of similarity metrics among populations of bacteria, eukaryotes, and opportunistic pathogens, as well as one significant association between mycobacterial and proteobacterial operational taxonomic units, provides insight into means by which manipulating the microbiome may lead to new avenues for limiting the growth of opportunistic pathogens (e.g., Legionella) or other nuisance organisms (e.g., nitrifiers).
Collapse
Affiliation(s)
- Hong Wang
- Via Department of Civil and Environmental Engineering, Virginia Tech , Blacksburg, Virginia 24061, United States
| | | | | | | | | |
Collapse
|
48
|
Wang H, Pryor MA, Edwards MA, Falkinham JO, Pruden A. Effect of GAC pre-treatment and disinfectant on microbial community structure and opportunistic pathogen occurrence. WATER RESEARCH 2013; 47:5760-72. [PMID: 23906775 DOI: 10.1016/j.watres.2013.06.052] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Revised: 06/21/2013] [Accepted: 06/27/2013] [Indexed: 05/10/2023]
Abstract
Opportunistic pathogens in potable water systems are an emerging health concern; however, the factors influencing their proliferation are poorly understood. Here we investigated the effects of prior granular activated carbon (GAC) biofiltration [GAC-filtered water, unfiltered water, and a blend (30% GAC filtered and 70% unfiltered water)] and disinfectant type (chlorine, chloramine) on opportunistic pathogen occurrence using five annular reactors (ARs) to simulate water distribution systems, particularly premise plumbing. GAC pre-treatment effectively reduced total organic carbon (TOC), resulting in three levels of influent TOC investigated. Quantitative polymerase chain reaction (q-PCR) provided molecular evidence of natural colonization of Legionella spp., Mycobacterium spp., Acanthamoeba spp., Hartmannella vermiformis and Mycobacterium avium on AR coupons. Cultivable mycobacteria and amoeba, including pathogenic species, were also found in bulk water and biofilm samples. While q-PCR tends to overestimate live cells, it provided a quantitative comparison of target organisms colonizing the AR biofilms in terms of gene copy numbers. In most cases, total bacteria and opportunistic pathogens were higher in the three undisinfected ARs, but the levels were not proportional to the level of GAC pre-treatment/TOC. Chlorine was more effective for controlling mycobacteria and Acanthamoeba, whereas chloramine was more effective for controlling Legionella. Both chlorine and chloramine effectively inhibited M. avium and H. vermiformis colonization. Pyrosequencing of 16S rRNA genes in coupon biofilms revealed a significant effect of GAC pre-treatment and disinfectant type on the microbial community structure. Overall, this study provides insights into the potential of different disinfectants and GAC biofilters at the treatment plant and in buildings to control downstream opportunistic pathogens and broader drinking water microbial communities.
Collapse
Affiliation(s)
- Hong Wang
- Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA 24061, USA
| | | | | | | | | |
Collapse
|
49
|
Brazeau RH, Edwards MA. Role of Hot Water System Design on Factors Influential to Pathogen Regrowth: Temperature, Chlorine Residual, Hydrogen Evolution, and Sediment. ENVIRONMENTAL ENGINEERING SCIENCE 2013; 30:617-627. [PMID: 24170969 PMCID: PMC3804227 DOI: 10.1089/ees.2012.0514] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Accepted: 07/13/2013] [Indexed: 05/25/2023]
Abstract
Residential water heating is linked to growth of pathogens in premise plumbing, which is the primary source of waterborne disease in the United States. Temperature and disinfectant residual are critical factors controlling increased concentration of pathogens, but understanding of how each factor varies in different water heater configurations is lacking. A direct comparative study of electric water heater systems was conducted to evaluate temporal variations in temperature and water quality parameters including dissolved oxygen levels, hydrogen evolution, total and soluble metal concentrations, and disinfectant decay. Recirculation tanks had much greater volumes of water at temperature ranges with potential for increased pathogen growth when set at 49°C compared with standard tank systems without recirculation. In contrast, when set at the higher end of acceptable ranges (i.e., 60°C), this relationship was reversed and recirculation systems had less volume of water at risk for pathogen growth compared with conventional systems. Recirculation tanks also tended to have much lower levels of disinfectant residual (standard systems had 40-600% higher residual), 4-6 times as much hydrogen, and 3-20 times more sediment compared with standard tanks without recirculation. On demand tankless systems had very small volumes of water at risk and relatively high levels of disinfectant residual. Recirculation systems may have distinct advantages in controlling pathogens via thermal disinfection if set at 60°C, but these systems have lower levels of disinfectant residual and greater volumes at risk if set at lower temperatures.
Collapse
Affiliation(s)
- Randi H. Brazeau
- Department of Earth and Atmospheric Sciences, Metropolitan State University of Denver, Denver, Colorado
| | - Marc A. Edwards
- Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, Virginia
| |
Collapse
|
50
|
Wang S, Huang J, Yang Y, Hui Y, Ge Y, Larssen T, Yu G, Deng S, Wang B, Harman C. First report of a Chinese PFOS alternative overlooked for 30 years: its toxicity, persistence, and presence in the environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:10117-28. [PMID: 23952109 DOI: 10.1021/es402455r] [Citation(s) in RCA: 100] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
This is the first report on the environmental occurrence of a chlorinated polyfluorinated ether sulfonate (locally called F-53B, C8ClF16O4SK). It has been widely applied as a mist suppressant by the chrome plating industry in China for decades but has evaded the attention of environmental research and regulation. In this study, F-53B was found in high concentrations (43-78 and 65-112 μg/L for the effluent and influent, respectively) in wastewater from the chrome plating industry in the city of Wenzhou, China. F-53B was not successfully removed by the wastewater treatments in place. Consequently, it was detected in surface water that receives the treated wastewater at similar levels to PFOS (ca. 10-50 ng/L) and the concentration decreased with the increasing distance from the wastewater discharge point along the river. Initial data presented here suggest that F-53B is moderately toxic (Zebrafish LC50-96 h 15.5 mg/L) and is as resistant to degradation as PFOS. While current usage is limited to the chrome plating industry, the increasing demand for PFOS alternatives in other sectors may result in expanded usage. Collectively, the results of this work call for future assessments on the effects of this overlooked contaminant and its presence and fate in the environment.
Collapse
Affiliation(s)
- Siwen Wang
- State Key Joint Laboratory of Environment Simulation and Pollution Control (SKJLESPC), School of Environment, POPs Research Centre, Tsinghua University , Beijing 100084, P.R. China
| | | | | | | | | | | | | | | | | | | |
Collapse
|