1
|
Amoakon JP, Lee J, Liyanage P, Arora K, Karlstaedt A, Mylavarapu G, Amin R, Naren AP. Defective CFTR modulates mechanosensitive channels TRPV4 and PIEZO1 and drives endothelial barrier failure. iScience 2024; 27:110703. [PMID: 39252977 PMCID: PMC11382128 DOI: 10.1016/j.isci.2024.110703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Revised: 06/25/2024] [Accepted: 08/06/2024] [Indexed: 09/11/2024] Open
Abstract
Cystic fibrosis (CF) is a genetic disease caused by a mutation in the cystic fibrosis transmembrane conductance regulator (CFTR) gene. Despite reports of CFTR expression on endothelial cells, pulmonary vascular perturbations, and perfusion deficits in CF patients, the mechanism of pulmonary vascular disease in CF remains unclear. Here, our pilot study of 40 CF patients reveals a loss of small pulmonary blood vessels in patients with severe lung disease. Using a vessel-on-a-chip model, we establish a shear-stress-dependent mechanism of endothelial barrier failure in CF involving TRPV4, a mechanosensitive channel. Furthermore, we demonstrate that CFTR deficiency downregulates the function of PIEZO1, another mechanosensitive channel involved in angiogenesis and wound repair, and exacerbates loss of small pulmonary blood vessel. We also show that CFTR directly interacts with PIEZO1 and enhances its function. Our study identifies key cellular targets to mitigate loss of small pulmonary blood vessels in CF.
Collapse
Affiliation(s)
- Jean-Pierre Amoakon
- Department of Systems Biology and Physiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Division of Pulmonary Medicine and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Jesun Lee
- Division of Pulmonary Medicine and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Pramodha Liyanage
- Division of Pulmonary Medicine and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Kavisha Arora
- Division of Pulmonary Medicine and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Anja Karlstaedt
- Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Goutham Mylavarapu
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Raouf Amin
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| | - Anjaparavanda P Naren
- Department of Systems Biology and Physiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Division of Pulmonary Medicine and Critical Care, Cedars-Sinai Medical Center, Los Angeles, CA, USA
- Division of Pulmonary Medicine, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
| |
Collapse
|
2
|
Annink ME, Kraaijenhof JM, Stroes ESG, Kroon J. Moving from lipids to leukocytes: inflammation and immune cells in atherosclerosis. Front Cell Dev Biol 2024; 12:1446758. [PMID: 39161593 PMCID: PMC11330886 DOI: 10.3389/fcell.2024.1446758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Accepted: 07/22/2024] [Indexed: 08/21/2024] Open
Abstract
Atherosclerotic cardiovascular disease (ASCVD) is the most important cause of morbidity and mortality worldwide. While it is traditionally attributed to lipid accumulation in the vascular endothelium, recent research has shown that plaque inflammation is an important additional driver of atherogenesis. Though clinical outcome trials utilizing anti-inflammatory agents have proven promising in terms of reducing ASCVD risk, it is imperative to identify novel actionable targets that are more specific to atherosclerosis to mitigate adverse effects associated with systemic immune suppression. To that end, this review explores the contributions of various immune cells from the innate and adaptive immune system in promoting and mitigating atherosclerosis by integrating findings from experimental studies, high-throughput multi-omics technologies, and epidemiological research.
Collapse
Affiliation(s)
- Maxim E. Annink
- Department of Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands
| | - Jordan M. Kraaijenhof
- Department of Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands
| | - Erik S. G. Stroes
- Department of Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands
| | - Jeffrey Kroon
- Department of Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands
- Department of Experimental Vascular Medicine, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands
- Laboratory of Angiogenesis and Vascular Metabolism, VIB-KU Leuven Center for Cancer Biology, Leuven, Belgium
- Laboratory of Angiogenesis and Vascular Metabolism, Department of Oncology, KU Leuven and Leuven Cancer Institute (LKI), Leuven, Belgium
- Amsterdam Cardiovascular Sciences, Atherosclerosis and Ischemic Syndromes, Amsterdam, Netherlands
| |
Collapse
|
3
|
Marino M, Sauty B, Vairo G. Unraveling the complexity of vascular tone regulation: a multiscale computational approach to integrating chemo-mechano-biological pathways with cardiovascular biomechanics. Biomech Model Mechanobiol 2024; 23:1091-1120. [PMID: 38507180 DOI: 10.1007/s10237-024-01826-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 02/09/2024] [Indexed: 03/22/2024]
Abstract
Vascular tone regulation is a crucial aspect of cardiovascular physiology, with significant implications for overall cardiovascular health. However, the precise physiological mechanisms governing smooth muscle cell contraction and relaxation remain uncertain. The complexity of vascular tone regulation stems from its multiscale and multifactorial nature, involving global hemodynamics, local flow conditions, tissue mechanics, and biochemical pathways. Bridging this knowledge gap and translating it into clinical practice presents a challenge. In this paper, a computational model is presented to integrate chemo-mechano-biological pathways with cardiovascular biomechanics, aiming to unravel the intricacies of vascular tone regulation. The computational framework combines an algebraic description of global hemodynamics with detailed finite element analyses at the scale of vascular segments for describing their passive and active mechanical response, as well as the molecular transport problem linked with chemo-biological pathways triggered by wall shear stresses. Their coupling is accounted for by considering a two-way interaction. Specifically, the focus is on the role of nitric oxide-related molecular pathways, which play a critical role in modulating smooth muscle contraction and relaxation to maintain vascular tone. The computational framework is employed to examine the interplay between localized alterations in the biomechanical response of a specific vessel segment-such as those induced by calcifications or endothelial dysfunction-and the broader global hemodynamic conditions-both under basal and altered states. The proposed approach aims to advance our understanding of vascular tone regulation and its impact on cardiovascular health. By incorporating chemo-mechano-biological mechanisms into in silico models, this study allows us to investigate cardiovascular responses to multifactorial stimuli and incorporate the role of adaptive homeostasis in computational biomechanics frameworks.
Collapse
Affiliation(s)
- Michele Marino
- Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy.
| | - Bastien Sauty
- Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy
- Mines Saint-Etienne, Université Jean Monnet, INSERM, U1059 SAINBIOSE, F-42023, Saint-Etienne, France
| | - Giuseppe Vairo
- Department of Civil Engineering and Computer Science Engineering, University of Rome Tor Vergata, Via del Politecnico 1, 00133, Rome, Italy
| |
Collapse
|
4
|
Rego BV, Murtada SI, Li G, Tellides G, Humphrey JD. Multiscale insights into postnatal aortic development. Biomech Model Mechanobiol 2024; 23:687-701. [PMID: 38151614 PMCID: PMC11419831 DOI: 10.1007/s10237-023-01800-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 11/27/2023] [Indexed: 12/29/2023]
Abstract
Despite its vital importance for establishing proper cardiovascular function, the process through which the vasculature develops and matures postnatally remains poorly understood. From a clinical perspective, an ability to mechanistically model the developmental time course in arteries and veins, as well as to predict how various pathologies and therapeutic interventions alter the affected vessels, promises to improve treatment strategies and long-term clinical outcomes, particularly in pediatric patients suffering from congenital heart defects. In the present study, we conducted a multiscale investigation into the postnatal development of the murine thoracic aorta, examining key allometric relations as well as relationships between in vivo mechanical stresses, collagen and elastin expression, and the gradual accumulation of load-bearing constituents within the aortic wall. Our findings suggest that the production of fibrillar collagens in the developing aorta associates strongly with the ratio of circumferential stresses between systole and diastole, hence emphasizing the importance of a pulsatile mechanobiological stimulus. Moreover, rates of collagen turnover and elastic fiber compaction can be inferred directly by synthesizing transcriptional data and quantitative histological measurements of evolving collagen and elastin content. Consistent with previous studies, we also observed that wall shear stresses acting on the aorta are similar at birth and in maturity, supporting the hypothesis that at least some stress targets are established early in development and maintained thereafter, thus providing a possible homeostatic basis to guide future experiments and inform future predictive modeling.
Collapse
Affiliation(s)
- Bruno V Rego
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Biological & Agricultural Engineering, Louisiana State University, Baton Rouge, LA, USA
| | - Sae-Il Murtada
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Guangxin Li
- Department of Surgery, Yale School of Medicine, New Haven, CT, USA
| | - George Tellides
- Department of Surgery, Yale School of Medicine, New Haven, CT, USA
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA.
| |
Collapse
|
5
|
Gray SG, Weinberg PD. Biomechanical determinants of endothelial permeability assessed in standard and modified hollow-fibre bioreactors. J R Soc Interface 2023; 20:20230222. [PMID: 37608710 PMCID: PMC10445023 DOI: 10.1098/rsif.2023.0222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/31/2023] [Indexed: 08/24/2023] Open
Abstract
Effects of mechanical stress on the permeability of vascular endothelium are important to normal physiology and in the development of atherosclerosis. Here we elucidate novel effects using commercially available and modified hollow-fibre bioreactors, in which endothelial cells form confluent monolayers lining plastic capillaries with porous walls, contained in a cartridge. The capillaries were perfused with a near-aortic waveform, and permeability was assessed by the movement of rhodamine-labelled albumin from the intracapillary to the extracapillary space. Permeability was increased by acute application of shear stress and decreased by chronic shear stress compared with a static control: this has previously been shown only for multidirectional flows. Increasing viscosity reduced permeability under both acute and chronic shear; since shear rate remained unchanged, these effects resulted from altered shear stress. Reducing pulsatility increased permeability, contrary to the widely held assumption that flow which is highly oscillatory causes endothelial dysfunction. Chronic convection across the monolayer increased effective permeability more than could be explained by the addition of advective transport, contrary to results from previous acute experiments. The off-the-shelf and modified bioreactors provide an excellent tool for investigating the biomechanics of endothelial permeability and have revealed novel effects of flow duration, viscosity, pulsatility and transmural flow.
Collapse
Affiliation(s)
- Stephen G. Gray
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| | - Peter D. Weinberg
- Department of Bioengineering, Imperial College London, London SW7 2AZ, UK
| |
Collapse
|
6
|
Lebas H, Boutigny A, Maupu C, Salfati J, Orset C, Mazighi M, Bonnin P, Boulaftali Y. Imaging Cerebral Arteries Tortuosity and Velocities by Transcranial Doppler Ultrasound Is a Reliable Assessment of Brain Aneurysm in Mouse Models. STROKE (HOBOKEN, N.J.) 2023; 3:e000476. [PMID: 37496732 PMCID: PMC10368188 DOI: 10.1161/svin.122.000476] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 10/11/2022] [Accepted: 10/28/2022] [Indexed: 07/28/2023]
Abstract
Background During the past few decades, several pathophysiological processes contributing to intracranial aneurysm (IA) rupture have been identified, including irregular IA shape, altered hemodynamic stress within the IA, and vessel wall inflammation. The use of preclinical models of IA and imaging tools is paramount to better understand the underlying disease mechanisms. Methods We used 2 established mouse models of IA, and we analyzed the progression of the IA by magnetic resonance imaging, transcranial Doppler, and histology. Results In both models of IA, we observed, by transcranial Doppler, a significant decrease of the blood velocities and wall shear stress of the internal carotid arteries. We also observed the formation of tortuous arteries in both models that were correlated with the presence of an aneurysm as confirmed by magnetic resonance imaging and histology. A high grade of tortuosity is associated with a significant decrease of the mean blood flow velocities and a greater artery dilation. Conclusions Transcranial Doppler is a robust and convenient imaging method to evaluate the progression of IA. Detection of decreased blood flow velocities and increased tortuosity can be used as reliable indicators of IA.
Collapse
Affiliation(s)
- Héloïse Lebas
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
| | - Alexandre Boutigny
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
- Service de Physiologie Clinique Explorations FonctionnellesAP‐HPHôpital Lariboisière–F WidalParisFrance
| | - Clémence Maupu
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
| | - Jonas Salfati
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
| | - Cyrille Orset
- UMR‐S U1237 “Physiopathology and Imaging of Neurological Disorders,”Centre CYCERONCaenFrance
| | - Mikael Mazighi
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
- Département de Neuroradiologie Interventionnelle de la Fondation Rothschild et Département de NeurologieHôpital LariboisièreParisFrance
| | - Philippe Bonnin
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
- Service de Physiologie Clinique Explorations FonctionnellesAP‐HPHôpital Lariboisière–F WidalParisFrance
| | - Yacine Boulaftali
- INSERM U1148Laboratory for Vascular Translational ScienceUniversité de Paris and Université Sorbonne Paris NordParisFrance
| |
Collapse
|
7
|
Mutlu O, Salman HE, Al-Thani H, El-Menyar A, Qidwai UA, Yalcin HC. How does hemodynamics affect rupture tissue mechanics in abdominal aortic aneurysm: Focus on wall shear stress derived parameters, time-averaged wall shear stress, oscillatory shear index, endothelial cell activation potential, and relative residence time. Comput Biol Med 2023; 154:106609. [PMID: 36724610 DOI: 10.1016/j.compbiomed.2023.106609] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/19/2023] [Accepted: 01/22/2023] [Indexed: 01/24/2023]
Abstract
An abdominal aortic aneurysm (AAA) is a critical health condition with a risk of rupture, where the diameter of the aorta enlarges more than 50% of its normal diameter. The incidence rate of AAA has increased worldwide. Currently, about three out of every 100,000 people have aortic diseases. The diameter and geometry of AAAs influence the hemodynamic forces exerted on the arterial wall. Therefore, a reliable assessment of hemodynamics is crucial for predicting the rupture risk. Wall shear stress (WSS) is an important metric to define the level of the frictional force on the AAA wall. Excessive levels of WSS deteriorate the remodeling mechanism of the arteries and lead to abnormal conditions. At this point, WSS-related hemodynamic parameters, such as time-averaged WSS (TAWSS), oscillatory shear index (OSI), endothelial cell activation potential (ECAP), and relative residence time (RRT) provide important information to evaluate the shear environment on the AAA wall in detail. Calculation of these parameters is not straightforward and requires a physical understanding of what they represent. In addition, computational fluid dynamics (CFD) solvers do not readily calculate these parameters when hemodynamics is simulated. This review aims to explain the WSS-derived parameters focusing on how these represent different characteristics of disturbed hemodynamics. A representative case is presented for spatial and temporal formulation that would be useful for interested researchers for practical calculations. Finally, recent hemodynamics investigations relating WSS-related parameters with AAA rupture risk assessment are presented. This review will be useful to understand the physical representation of WSS-related parameters in cardiovascular flows and how they can be calculated practically for AAA investigations.
Collapse
Affiliation(s)
- Onur Mutlu
- Biomedical Research Center, Qatar University, Doha, Qatar
| | - Huseyin Enes Salman
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| | - Hassan Al-Thani
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar
| | - Ayman El-Menyar
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar; Clinical Medicine, Weill Cornell Medical College, Doha, Qatar
| | - Uvais Ahmed Qidwai
- Department of Computer Science Engineering, Qatar University, Doha, Qatar
| | | |
Collapse
|
8
|
Abstract
Atherosclerosis is a chronic inflammatory disease of the arterial wall, characterized by the formation of plaques containing lipid, connective tissue and immune cells in the intima of large and medium-sized arteries. Over the past three decades, a substantial reduction in cardiovascular mortality has been achieved largely through LDL-cholesterol-lowering regimes and therapies targeting other traditional risk factors for cardiovascular disease, such as hypertension, smoking, diabetes mellitus and obesity. However, the overall benefits of targeting these risk factors have stagnated, and a huge global burden of cardiovascular disease remains. The indispensable role of immunological components in the establishment and chronicity of atherosclerosis has come to the forefront as a clinical target, with proof-of-principle studies demonstrating the benefit and challenges of targeting inflammation and the immune system in cardiovascular disease. In this Review, we provide an overview of the role of the immune system in atherosclerosis by discussing findings from preclinical research and clinical trials. We also identify important challenges that need to be addressed to advance the field and for successful clinical translation, including patient selection, identification of responders and non-responders to immunotherapies, implementation of patient immunophenotyping and potential surrogate end points for vascular inflammation. Finally, we provide strategic guidance for the translation of novel targets of immunotherapy into improvements in patient outcomes. In this Review, the authors provide an overview of the immune cells involved in atherosclerosis, discuss preclinical research and published and ongoing clinical trials assessing the therapeutic potential of targeting the immune system in atherosclerosis, highlight emerging therapeutic targets from preclinical studies and identify challenges for successful clinical translation. Inflammation is an important component of the pathophysiology of cardiovascular disease; an imbalance between pro-inflammatory and anti-inflammatory processes drives chronic inflammation and the formation of atherosclerotic plaques in the vessel wall. Clinical trials assessing canakinumab and colchicine therapies in atherosclerotic cardiovascular disease have provided proof-of-principle of the benefits associated with therapeutic targeting of the immune system in atherosclerosis. The immunosuppressive adverse effects associated with the systemic use of anti-inflammatory drugs can be minimized through targeted delivery of anti-inflammatory drugs to the atherosclerotic plaque, defining the window of opportunity for treatment and identifying more specific targets for cardiovascular inflammation. Implementing immunophenotyping in clinical trials in patients with atherosclerotic cardiovascular disease will allow the identification of immune signatures and the selection of patients with the highest probability of deriving benefit from a specific therapy. Clinical stratification via novel risk factors and discovery of new surrogate markers of vascular inflammation are crucial for identifying new immunotherapeutic targets and their successful translation into the clinic.
Collapse
|
9
|
Barral M, El-Sanharawi I, Dohan A, Sebuhyan M, Guedon A, Delarue A, Boutigny A, Mohamedi N, Magnan B, Kemel S, Ketfi C, Kubis N, Bisdorff-Bresson A, Pocard M, Bonnin P. Blood Flow and Shear Stress Allow Monitoring of Progression and Prognosis of Tumor Diseases. Front Physiol 2021; 12:693052. [PMID: 34413786 PMCID: PMC8369886 DOI: 10.3389/fphys.2021.693052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 06/25/2021] [Indexed: 11/13/2022] Open
Abstract
In the presence of tumor angiogenesis, blood flow must increase, leading to an elevation of blood flow velocities (BFVels) and wall shear stress (WSS) in upstream native arteries. An adaptive arterial remodeling is stimulated, whose purpose lies in the enlargement of the arterial inner diameter, aiming for normalization of BFVels and WSS. Remodeling engages delayed processes that are efficient only several weeks/months after initiation, independent from those governing expansion of the neovascular network. Therefore, during tumor expansion, there is a time interval during which elevation of BFVels and WSS could reflect disease progression. Conversely, during the period of stability, BFVels and WSS drop back to normal values due to the achievement of remodeling processes. Ovarian peritoneal carcinomatosis (OPC), pseudomyxoma peritonei (PMP), and superficial arteriovenous malformations (AVMs) are diseases characterized by the development of abnormal vascular networks developed on native ones. In OPC and PMP, preoperative blood flow in the superior mesenteric artery (SMA) correlated with the per-operative peritoneal carcinomatosis index (OPC: n = 21, R = 0.79, p < 0.0001, PMP: n = 66, R = 0.63, p < 0.0001). Moreover, 1 year after surgery, WSS in the SMA helped in distinguishing patients with PMP from those without disease progression [ROC-curve analysis, AUC = 0.978 (0.902-0.999), p < 0.0001, sensitivity: 100.0%, specificity: 93.5%, cutoff: 12.1 dynes/cm2]. Similarly, WSS in the ipsilateral afferent arteries close to the lesion distinguished stable from progressive AVM [ROC-curve analysis, AUC: 0.988, (0.919-1.000), p < 0.0001, sensitivity: 93.5%, specificity: 95.7%; cutoff: 26.5 dynes/cm2]. Blood flow volume is indicative of the tumor burden in OPC and PMP, and WSS represents an early sensitive and specific vascular marker of disease progression in PMP and AVM.
Collapse
Affiliation(s)
- Matthias Barral
- INSERM UMR1275, Université de Paris, Hôpital Lariboisière, Paris, France
| | - Imane El-Sanharawi
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Anthony Dohan
- INSERM UMR1275, Université de Paris, Hôpital Lariboisière, Paris, France
| | - Maxime Sebuhyan
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Alexis Guedon
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Audrey Delarue
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Alexandre Boutigny
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France.,INSERM UMR1148 - LVTS, Université de Paris, Hôpital Bichat, Paris, France
| | - Nassim Mohamedi
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Benjamin Magnan
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Salim Kemel
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Chahinez Ketfi
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France
| | - Nathalie Kubis
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France.,INSERM UMR1148 - LVTS, Université de Paris, Hôpital Bichat, Paris, France
| | - Annouk Bisdorff-Bresson
- AP-HP, Université de Paris, Hôpital Lariboisière, Neuroradiologie, Centre Constitutif des Malformations Artério Veineuses Superficielles de l'Enfant et de l'Adulte, Paris, France
| | - Marc Pocard
- INSERM UMR1275, Université de Paris, Hôpital Lariboisière, Paris, France.,AP-HP, Sorbonne-Université, Hôpital Pitié-Salpêtrière, Chirurgie Digestive et Cancérologique, Paris, France
| | - Philippe Bonnin
- AP-HP, Université de Paris, Hôpital Lariboisière, Physiologie Clinique - Explorations Fonctionnelles, Paris, France.,INSERM UMR1148 - LVTS, Université de Paris, Hôpital Bichat, Paris, France
| |
Collapse
|
10
|
Bai H, Sadaghianloo N, Gorecka J, Liu S, Ono S, Ramachandra AB, Bonnet S, Mazure NM, Declemy S, Humphrey JD, Dardik A. Artery to vein configuration of arteriovenous fistula improves hemodynamics to increase maturation and patency. Sci Transl Med 2021; 12:12/557/eaax7613. [PMID: 32817365 DOI: 10.1126/scitranslmed.aax7613] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2019] [Revised: 03/17/2020] [Accepted: 06/09/2020] [Indexed: 12/21/2022]
Abstract
Arteriovenous fistulae (AVF) are the preferred mode of hemodialysis access, but 60% of conventional [vein-to-artery (V-A)] AVF fail to mature, and only 50% remain patent at 1 year. We previously showed improved maturation and patency in a pilot study of the radial artery deviation and reimplantation (RADAR) technique that uses an artery-to-vein (A-V) configuration. Here, we show that RADAR exhibits higher rates of maturation, as well as increased primary and secondary long-term patencies. RADAR is also protective in female patients, where it is associated with decreased reintervention rates and improved secondary patency. RADAR and conventional geometries were compared further in a rat bilateral carotid artery-internal jugular vein fistula model. There was decreased cell proliferation and neointimal hyperplasia in the A-V configuration in male and female animals, but no difference in hypoxia between the A-V and V-A configurations. Similar trends were seen in uremic male rats. The A-V configuration also associated with increased peak systolic velocity and expression of Kruppel-like factor 2 and phosphorylated endothelial nitric oxide synthase, consistent with improved hemodynamics. Computed tomography and ultrasound-informed computational modeling showed different hemodynamics in the A-V and V-A configurations, and improving the hemodynamics in the V-A configuration was protective against neointimal hyperplasia. These findings collectively demonstrate that RADAR is a durable surgical option for patients requiring radial-cephalic AVF for hemodialysis access.
Collapse
Affiliation(s)
- Hualong Bai
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA.,Department of Surgery, Yale School of Medicine, New Haven, CT 06520, USA.,Department of Vascular and Endovascular Surgery, First Affiliated Hospital of Zhengzhou University, Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City, Henan 450052, China
| | - Nirvana Sadaghianloo
- Université Côte d'Azur, Centre Méditerranéen de Médecine Moléculaire, INSERM 1065, 06200 Nice, France.,Centre Hospitalier Universitaire de Nice, Department of Vascular Surgery, 06000 Nice, France
| | - Jolanta Gorecka
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA.,Department of Surgery, Yale School of Medicine, New Haven, CT 06520, USA
| | - Shirley Liu
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA.,Department of Surgery, Yale School of Medicine, New Haven, CT 06520, USA
| | - Shun Ono
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA
| | - Abhay B Ramachandra
- Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| | - Sophie Bonnet
- Centre Hospitalier Universitaire de Nice, Department of Vascular Surgery, 06000 Nice, France
| | - Nathalie M Mazure
- Université Côte d'Azur, Centre Méditerranéen de Médecine Moléculaire, INSERM 1065, 06200 Nice, France
| | - Serge Declemy
- Centre Hospitalier Universitaire de Nice, Department of Vascular Surgery, 06000 Nice, France
| | - Jay D Humphrey
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA.,Department of Biomedical Engineering, Yale University, New Haven, CT 06520, USA
| | - Alan Dardik
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT 06520, USA. .,Department of Surgery, Yale School of Medicine, New Haven, CT 06520, USA.,Division of Vascular and Endovascular Surgery, Department of Surgery, Yale School of Medicine, New Haven, CT 06519, USA.,Department of Surgery, VA Connecticut Healthcare System, West Haven, CT 06516, USA
| |
Collapse
|
11
|
Murtada SI, Kawamura Y, Li G, Schwartz MA, Tellides G, Humphrey JD. Developmental origins of mechanical homeostasis in the aorta. Dev Dyn 2021; 250:629-639. [PMID: 33341996 PMCID: PMC8089041 DOI: 10.1002/dvdy.283] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 10/25/2020] [Accepted: 12/15/2020] [Indexed: 12/19/2022] Open
Abstract
BACKGROUND Mechanical homeostasis promotes proper aortic structure and function. Pathological conditions may arise, in part, from compromised or lost homeostasis. There is thus a need to quantify the homeostatic state and when it emerges. Here we quantify changes in mechanical loading, geometry, structure, and function of the murine aorta from the late prenatal period into maturity. RESULTS Our data suggest that a homeostatic set-point is established by postnatal day P2 for the flow-induced shear stress experienced by endothelial cells; this value deviates from its set-point from P10 to P21 due to asynchronous changes in mechanical loading (flow, pressure) and geometry (radius, wall thickness), but is restored thereafter consistent with homeostasis. Smooth muscle contractility also decreases during this period of heightened matrix deposition but is also restored in maturity. The pressure-induced mechanical stress experienced by intramural cells initially remains low despite increasing blood pressure, and then increases while extracellular matrix accumulates. CONCLUSIONS These findings suggest that cell-level mechanical homeostasis emerges soon after birth to allow mechanosensitive cells to guide aortic development, with deposition of matrix after P2 increasingly stress shielding intramural cells. The associated tissue-level set-points that emerge for intramural stress can be used to assess and model the aorta that matures biomechanically by P56.
Collapse
Affiliation(s)
- Sae-Il Murtada
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
| | - Yuki Kawamura
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Department of Molecular, Cellular, and Developmental Biology, Yale University, New Haven, Connecticut, USA
| | - Guangxin Li
- Department of Surgery, Yale School of Medicine, New Haven, Connecticut, USA
| | - Martin A Schwartz
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Department of Cell Biology, Yale School of Medicine, New Haven, Connecticut, USA
| | - George Tellides
- Department of Surgery, Yale School of Medicine, New Haven, Connecticut, USA
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, Connecticut, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, Connecticut, USA
| |
Collapse
|
12
|
Andelovic K, Winter P, Jakob PM, Bauer WR, Herold V, Zernecke A. Evaluation of Plaque Characteristics and Inflammation Using Magnetic Resonance Imaging. Biomedicines 2021; 9:185. [PMID: 33673124 PMCID: PMC7917750 DOI: 10.3390/biomedicines9020185] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 02/08/2021] [Accepted: 02/09/2021] [Indexed: 12/19/2022] Open
Abstract
Atherosclerosis is an inflammatory disease of large and medium-sized arteries, characterized by the growth of atherosclerotic lesions (plaques). These plaques often develop at inner curvatures of arteries, branchpoints, and bifurcations, where the endothelial wall shear stress is low and oscillatory. In conjunction with other processes such as lipid deposition, biomechanical factors lead to local vascular inflammation and plaque growth. There is also evidence that low and oscillatory shear stress contribute to arterial remodeling, entailing a loss in arterial elasticity and, therefore, an increased pulse-wave velocity. Although altered shear stress profiles, elasticity and inflammation are closely intertwined and critical for plaque growth, preclinical and clinical investigations for atherosclerosis mostly focus on the investigation of one of these parameters only due to the experimental limitations. However, cardiovascular magnetic resonance imaging (MRI) has been demonstrated to be a potent tool which can be used to provide insights into a large range of biological parameters in one experimental session. It enables the evaluation of the dynamic process of atherosclerotic lesion formation without the need for harmful radiation. Flow-sensitive MRI provides the assessment of hemodynamic parameters such as wall shear stress and pulse wave velocity which may replace invasive and radiation-based techniques for imaging of the vascular function and the characterization of early plaque development. In combination with inflammation imaging, the analyses and correlations of these parameters could not only significantly advance basic preclinical investigations of atherosclerotic lesion formation and progression, but also the diagnostic clinical evaluation for early identification of high-risk plaques, which are prone to rupture. In this review, we summarize the key applications of magnetic resonance imaging for the evaluation of plaque characteristics through flow sensitive and morphological measurements. The simultaneous measurements of functional and structural parameters will further preclinical research on atherosclerosis and has the potential to fundamentally improve the detection of inflammation and vulnerable plaques in patients.
Collapse
Affiliation(s)
- Kristina Andelovic
- Institute of Experimental Biomedicine, University Hospital Würzburg, 97080 Würzburg, Germany
- Experimental Physics V, University of Würzburg, 97074 Würzburg, Germany; (P.W.); (P.M.J.); (V.H.)
| | - Patrick Winter
- Experimental Physics V, University of Würzburg, 97074 Würzburg, Germany; (P.W.); (P.M.J.); (V.H.)
- Internal Medicine I, Cardiology, University Hospital Würzburg, 97080 Würzburg, Germany;
| | - Peter Michael Jakob
- Experimental Physics V, University of Würzburg, 97074 Würzburg, Germany; (P.W.); (P.M.J.); (V.H.)
| | - Wolfgang Rudolf Bauer
- Internal Medicine I, Cardiology, University Hospital Würzburg, 97080 Würzburg, Germany;
| | - Volker Herold
- Experimental Physics V, University of Würzburg, 97074 Würzburg, Germany; (P.W.); (P.M.J.); (V.H.)
| | - Alma Zernecke
- Institute of Experimental Biomedicine, University Hospital Würzburg, 97080 Würzburg, Germany
| |
Collapse
|
13
|
Panteleev MA, Korin N, Reesink KD, Bark DL, Cosemans JMEM, Gardiner EE, Mangin PH. Wall shear rates in human and mouse arteries: Standardization of hemodynamics for in vitro blood flow assays: Communication from the ISTH SSC subcommittee on biorheology. J Thromb Haemost 2021; 19:588-595. [PMID: 34396692 DOI: 10.1111/jth.15174] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 11/04/2020] [Accepted: 11/05/2020] [Indexed: 12/26/2022]
Abstract
Hemodynamics play a central role in hemostasis and thrombosis by affecting all aspects linked to platelet functions and coagulation. In vitro flow devices are extensively used in basic research, pharmacological studies, antiplatelet agent screening, and development of diagnostic tools. Because hemodynamic conditions vary tremendously throughout the vascular tree and among different (patho)physiological processes, it is important to use flow conditions based on relevant biorheological reference ranges. Surprisingly, it is particularly difficult to find a concise overview of relevant hemodynamic parameters in various human and mouse vessels. To our knowledge, this is the first time an inventory of flow conditions in healthy, non-diseased, human and mouse vessels has been created. The objective of providing such a repertoire is to aid researchers in the field of hemostasis and thrombosis in choosing rheological conditions relevant in in vitro flow experiments and to promote harmonization of flow-based assays to facilitate comparative evaluations between studies. With reference to the human, we discuss relevant similarities and discrepancies in wall shear rates in the mouse, which are typically one order of magnitude greater in agreement with allometric scaling laws between species. Importantly, we bring the attention of the researchers to the fact that the relevant range of average wall shear rates in human arteries where clinically relevant arterial thrombosis occurs may fall as low as 100 to 200 s-1, thus significantly overlapping with what are considered "venous" shear rates. The same range for the murine arteries used for arterial thrombosis models may significantly exceed 1000 s-1 reaching values considered to be "pathological."
Collapse
Affiliation(s)
- Mikhail A Panteleev
- Center for Theoretical Problems of Physicochemical Pharmacology, Moscow, Russia
- National Medical Research Center of Pediatric Hematology, Oncology and Immunology named after Dmitry Rogachev, Moscow, Russia
| | - Netanel Korin
- Department of Biomedical Engineering Technion, Israel Institute of Technology Haifa, Haifa, Israel
| | - Koen D Reesink
- Department of Biomedical Engineering, Maastricht University Medical Centre, Maastricht, the Netherlands
| | - David L Bark
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Judith M E M Cosemans
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands
| | - Elizabeth E Gardiner
- The John Curtin School of Medical Research, ACRF Department of Cancer Biology and Therapeutics, The Australian National University, Canberra, ACT, Australia
| | - Pierre H Mangin
- INSERM, EFS Grand-Est, BPPS UMR-S1255, FMTS, Université de Strasbourg, Strasbourg, France
| |
Collapse
|
14
|
Sangha GS, Goergen CJ, Prior SJ, Ranadive SM, Clyne AM. Preclinical techniques to investigate exercise training in vascular pathophysiology. Am J Physiol Heart Circ Physiol 2021; 320:H1566-H1600. [PMID: 33385323 PMCID: PMC8260379 DOI: 10.1152/ajpheart.00719.2020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Atherosclerosis is a dynamic process starting with endothelial dysfunction and inflammation and eventually leading to life-threatening arterial plaques. Exercise generally improves endothelial function in a dose-dependent manner by altering hemodynamics, specifically by increased arterial pressure, pulsatility, and shear stress. However, athletes who regularly participate in high-intensity training can develop arterial plaques, suggesting alternative mechanisms through which excessive exercise promotes vascular disease. Understanding the mechanisms that drive atherosclerosis in sedentary versus exercise states may lead to novel rehabilitative methods aimed at improving exercise compliance and physical activity. Preclinical tools, including in vitro cell assays, in vivo animal models, and in silico computational methods, broaden our capabilities to study the mechanisms through which exercise impacts atherogenesis, from molecular maladaptation to vascular remodeling. Here, we describe how preclinical research tools have and can be used to study exercise effects on atherosclerosis. We then propose how advanced bioengineering techniques can be used to address gaps in our current understanding of vascular pathophysiology, including integrating in vitro, in vivo, and in silico studies across multiple tissue systems and size scales. Improving our understanding of the antiatherogenic exercise effects will enable engaging, targeted, and individualized exercise recommendations to promote cardiovascular health rather than treating cardiovascular disease that results from a sedentary lifestyle.
Collapse
Affiliation(s)
- Gurneet S Sangha
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland
| | - Craig J Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana.,Purdue University Center for Cancer Research, Purdue University, West Lafayette, Indiana
| | - Steven J Prior
- Department of Kinesiology, University of Maryland School of Public Health, College Park, Maryland.,Baltimore Veterans Affairs Geriatric Research, Education, and Clinical Center, Baltimore, Maryland
| | - Sushant M Ranadive
- Department of Kinesiology, University of Maryland School of Public Health, College Park, Maryland
| | - Alisa M Clyne
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland
| |
Collapse
|
15
|
Zbinden JC, Blum KM, Berman AG, Ramachandra AB, Szafron JM, Kerr KE, Anderson JL, Sangha GS, Earl CC, Nigh NR, Mirhaidari GJM, Reinhardt JW, Chang Y, Yi T, Smalley R, Gabriele PD, Harris JJ, Humphrey JD, Goergen CJ, Breuer CK. Effects of Braiding Parameters on Tissue Engineered Vascular Graft Development. Adv Healthc Mater 2020; 9:e2001093. [PMID: 33063452 DOI: 10.1002/adhm.202001093] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2020] [Revised: 09/17/2020] [Indexed: 01/06/2023]
Abstract
Tissue engineered vascular grafts (TEVGs) using scaffolds fabricated from braided poly(glycolic acid) (PGA) fibers coated with poly(glycerol sebacate) (PGS) are developed. The approach relies on in vivo tissue engineering by which neotissue forms solely within the body after a scaffold has been implanted. Herein, the impact of altering scaffold braid design and scaffold coating on neotissue formation is investigated. Several combinations of braiding parameters are manufactured and evaluated in a Beige mouse model in the infrarenal abdominal aorta. Animals are followed with 4D ultrasound analysis, and 12 week explanted vessels are evaluated for biaxial mechanical properties as well as histological composition. Results show that scaffold parameters (i.e., braiding angle, braiding density, and presence of a PGS coating) have interdependent effects on the resulting graft performance, namely, alteration of these parameters influences levels of inflammation, extracellular matrix production, graft dilation, neovessel distensibility, and overall survival. Coupling carefully designed in vivo experimentation with regression analysis, critical relationships between the scaffold design and the resulting neotissue that enable induction of favorable cellular and extracellular composition in a controlled manner are uncovered. Such an approach provides a potential for fabricating scaffolds with a broad range of features and the potential to manufacture optimized TEVGs.
Collapse
Affiliation(s)
- Jacob C. Zbinden
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - Kevin M. Blum
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - Alycia G. Berman
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Abhay B. Ramachandra
- Department of Biomedical Engineering, Yale University 55 Prospect Street New Haven CT 06520 USA
| | - Jason M. Szafron
- Department of Biomedical Engineering, Yale University 55 Prospect Street New Haven CT 06520 USA
| | - Katherine E. Kerr
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Jennifer L. Anderson
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Gurneet S. Sangha
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Conner C. Earl
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Noah R. Nigh
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Gabriel J. M. Mirhaidari
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - James W. Reinhardt
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - Yu‐Chun Chang
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - Tai Yi
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| | - Ryan Smalley
- Secant Group, LLC 551 East Church Ave Telford PA 18969 USA
| | | | | | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University 55 Prospect Street New Haven CT 06520 USA
| | - Craig J. Goergen
- Weldon School of Biomedical Engineering, Purdue University 206 S Martin Jischke Drive West Lafayette IN 47907 USA
| | - Christopher K. Breuer
- Nationwide Children's Hospital, Abagail Wexner Research Institute 575 Children's Crossroad Columbus OH 43215 USA
| |
Collapse
|
16
|
Humphrey JD. Mechanisms of Vascular Remodeling in Hypertension. Am J Hypertens 2020; 34:432-441. [PMID: 33245319 PMCID: PMC8140657 DOI: 10.1093/ajh/hpaa195] [Citation(s) in RCA: 50] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 11/09/2020] [Accepted: 11/19/2020] [Indexed: 12/19/2022] Open
Abstract
Hypertension is both a cause and a consequence of central artery stiffening, which in turn is an initiator and indicator of myriad disease conditions and thus all-cause mortality. Such stiffening results from a remodeling of the arterial wall that is driven by mechanical stimuli and mediated by inflammatory signals, which together lead to differential gene expression and concomitant changes in extracellular matrix composition and organization. This review focuses on biomechanical mechanisms by which central arteries remodel in hypertension within the context of homeostasis-what promotes it, what prevents it. It is suggested that the vasoactive capacity of the wall and inflammatory burden strongly influence the ability of homeostatic mechanisms to adapt the arterial wall to high blood pressure or not. Maladaptation, often reflected by inflammation-driven adventitial fibrosis, not just excessive intimal-medial thickening, significantly diminishes central artery function and disturbs hemodynamics, ultimately compromising end organ perfusion and thus driving the associated morbidity and mortality. It is thus suggested that there is a need for increased attention to controlling both smooth muscle phenotype and inflammation in hypertensive remodeling of central arteries, with future studies of the often adaptive response of medium-sized muscular arteries promising to provide additional guidance.
Collapse
Affiliation(s)
- Jay D Humphrey
- Department of Biomedical Engineering, Vascular Biology and Therapeutics Program, Yale University, New Haven, Connecticut, USA,Correspondence: Jay D. Humphrey ()
| |
Collapse
|
17
|
Riedl KA, Kampf T, Herold V, Behr VC, Bauer WR. Wall shear stress analysis using 17.6 Tesla MRI: A longitudinal study in ApoE-/- mice with histological analysis. PLoS One 2020; 15:e0238112. [PMID: 32857805 PMCID: PMC7454980 DOI: 10.1371/journal.pone.0238112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Accepted: 08/10/2020] [Indexed: 12/31/2022] Open
Abstract
This longitudinal study was performed to evaluate the feasibility of detecting the interaction between wall shear stress (WSS) and plaque development. 20 ApoE-/- mice were separated in 12 mice with Western Diet and 8 mice with Chow Diet. Magnetic resonance (MR) scans at 17.6 Tesla and histological analysis were performed after one week, eight and twelve weeks. All in vivo MR measurements were acquired using a flow sensitive phase contrast method for determining vectorial flow. Histological sections were stained with Hematoxylin and Eosin, Elastica van Gieson and CD68 staining. Data analysis was performed using Ensight and a Matlab-based “Flow Tool”. The body weight of ApoE-/- mice increased significantly over 12 weeks. WSS values increased in the Western Diet group over the time period; in contrast, in the Chow Diet group the values decreased from the first to the second measurement point. Western Diet mice showed small plaque formations with elastin fragmentations after 8 weeks and big plaque formations after 12 weeks; Chow Diet mice showed a few elastin fragmentations after 8 weeks and small plaque formations after 12 weeks. Favored by high-fat diet, plaque formation results in higher values of WSS. With wall shear stress being a known predictor for atherosclerotic plaque development, ultra highfield MRI can serve as a tool for studying the causes and beginnings of atherosclerosis.
Collapse
Affiliation(s)
- Katharina A. Riedl
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
- Department of Cardiology, University Heart & Vascular Center Hamburg, Hamburg, Germany
- * E-mail:
| | - Thomas Kampf
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Würzburg, Würzburg, Germany
| | - Volker Herold
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
| | - Volker C. Behr
- Department of Experimental Physics V, University of Würzburg, Würzburg, Germany
| | - Wolfgang R. Bauer
- Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany
| |
Collapse
|
18
|
Bäumler K, Vedula V, Sailer AM, Seo J, Chiu P, Mistelbauer G, Chan FP, Fischbein MP, Marsden AL, Fleischmann D. Fluid-structure interaction simulations of patient-specific aortic dissection. Biomech Model Mechanobiol 2020; 19:1607-1628. [PMID: 31993829 DOI: 10.1007/s10237-020-01294-8] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 01/14/2020] [Indexed: 12/01/2022]
Abstract
Credible computational fluid dynamic (CFD) simulations of aortic dissection are challenging, because the defining parallel flow channels-the true and the false lumen-are separated from each other by a more or less mobile dissection membrane, which is made up of a delaminated portion of the elastic aortic wall. We present a comprehensive numerical framework for CFD simulations of aortic dissection, which captures the complex interplay between physiologic deformation, flow, pressures, and time-averaged wall shear stress (TAWSS) in a patient-specific model. Our numerical model includes (1) two-way fluid-structure interaction (FSI) to describe the dynamic deformation of the vessel wall and dissection flap; (2) prestress and (3) external tissue support of the structural domain to avoid unphysiologic dilation of the aortic wall and stretching of the dissection flap; (4) tethering of the aorta by intercostal and lumbar arteries to restrict translatory motion of the aorta; and a (5) independently defined elastic modulus for the dissection flap and the outer vessel wall to account for their different material properties. The patient-specific aortic geometry is derived from computed tomography angiography (CTA). Three-dimensional phase contrast magnetic resonance imaging (4D flow MRI) and the patient's blood pressure are used to inform physiologically realistic, patient-specific boundary conditions. Our simulations closely capture the cyclical deformation of the dissection membrane, with flow simulations in good agreement with 4D flow MRI. We demonstrate that decreasing flap stiffness from [Formula: see text] to [Formula: see text] kPa (a) increases the displacement of the dissection flap from 1.4 to 13.4 mm, (b) decreases the surface area of TAWSS by a factor of 2.3, (c) decreases the mean pressure difference between true lumen and false lumen by a factor of 0.63, and (d) decreases the true lumen flow rate by up to 20% in the abdominal aorta. We conclude that the mobility of the dissection flap substantially influences local hemodynamics and therefore needs to be accounted for in patient-specific simulations of aortic dissection. Further research to accurately measure flap stiffness and its local variations could help advance future CFD applications.
Collapse
Affiliation(s)
- Kathrin Bäumler
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, Stanford, CA, 94305, USA.
| | - Vijay Vedula
- Department of Pediatrics (Cardiology), Stanford University, Stanford, CA, 94305, USA
| | - Anna M Sailer
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Jongmin Seo
- Department of Pediatrics (Cardiology), Stanford University, Stanford, CA, 94305, USA
| | - Peter Chiu
- Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, 94305, USA
| | - Gabriel Mistelbauer
- Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany
| | - Frandics P Chan
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| | - Michael P Fischbein
- Department of Cardiothoracic Surgery, Stanford University, Stanford, CA, 94305, USA
| | - Alison L Marsden
- Department of Bioengineering, Stanford University, Stanford, CA, 94305, USA
| | - Dominik Fleischmann
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, Stanford, CA, 94305, USA
| |
Collapse
|
19
|
Hu Q, Nelson TJ, Seymour RS. Bone foramen dimensions and blood flow calculation: best practices. J Anat 2019; 236:357-369. [PMID: 31713844 DOI: 10.1111/joa.13106] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/18/2019] [Indexed: 02/06/2023] Open
Abstract
Some blood vessels enter bones through foramina, leaving the size of the foramen as a gauge for estimating the rate of blood flow and hence the metabolic rate of the supplied tissues. Foramen dimensions have been measured using varied methods in previous foramen studies, to relate regional blood flows with associated physiological processes. With the increasing interests in this 'foramen technique', standard methods with minimized measurement errors are therefore required. This study provides details of microphotographic and micro-computerized tomographic methods, and introduces a new alternative method, which uses impression material to measure foramen dimensions. The three methods are compared and the results indicate that all of them are capable of obtaining precise and accurate foramen dimension values, although they all have limitations. A microphotograph of the external opening is suggested to be the standard method because of its ease of use, but the alternative methods provide more detailed information on foramen shape. If the foramen is mainly occupied by one artery, blood flow rates can be calculated from foramen size and artery wall-lumen ratio, which is evaluated from the literature survey in this study. If veins or nerves also penetrate the foramen, a relative index of blood flow rate is nevertheless possible for comparative purposes.
Collapse
Affiliation(s)
- Qiaohui Hu
- School of Biological Sciences, University of Adelaide, Adelaide, SA, Australia
| | - Thomas J Nelson
- School of Biological Sciences, University of Adelaide, Adelaide, SA, Australia
| | - Roger S Seymour
- School of Biological Sciences, University of Adelaide, Adelaide, SA, Australia
| |
Collapse
|
20
|
Seymour RS, Hu Q, Snelling EP. Blood flow rate and wall shear stress in seven major cephalic arteries of humans. J Anat 2019; 236:522-530. [PMID: 31710396 DOI: 10.1111/joa.13119] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2019] [Indexed: 12/21/2022] Open
Abstract
Blood flow rate ( Q ˙ ) in relation to arterial lumen radius (ri ) is commonly modelled according to theoretical equations and paradigms, including Murray's Law ( Q ˙ ∝ r i 3 ) and da Vinci's Rule ( Q ˙ ∝ r i 2 ). Wall shear stress (τ) is independent of ri with Murray's Law (τ ∝ r i 0 ) and decreases with da Vinci's Rule (τ ∝ r i - 1 ). These paradigms are tested empirically with a meta-analysis of the relationships between Q ˙ and ri in seven major arteries of the human cephalic circulation from 19 imaging studies in which both variables were presented. The analysis shows that Q ˙ ∝ r i 2.16 and τ ∝ r i - 1.02 , more consistent with da Vinci's Rule than Murray's Law. This meta-analysis provides standard values for Q ˙ , ri and τ in the human cephalic arteries that may be a useful baseline in future investigations. On average, the paired internal carotid arteries supply 75%, and the vertebral arteries supply 25%, of total brain blood flow. The internal carotid arteries contribute blood entirely to the anterior and middle cerebral arteries and also partly to the posterior cerebral arteries via the posterior communicating arteries of the circle of Willis. On average, the internal carotid arteries provide 88% of the blood flow to the cerebrum and the vertebral arteries only 12%.
Collapse
Affiliation(s)
- Roger S Seymour
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA, Australia
| | - Qiaohui Hu
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA, Australia
| | - Edward P Snelling
- Department of Anatomy and Physiology, Faculty of Veterinary Science, University of Pretoria, Pretoria, South Africa.,Brain Function Research Group, School of Physiology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa
| |
Collapse
|
21
|
Winter P, Andelovic K, Kampf T, Gutjahr FT, Heidenreich J, Zernecke A, Bauer WR, Jakob PM, Herold V. Fast self-navigated wall shear stress measurements in the murine aortic arch using radial 4D-phase contrast cardiovascular magnetic resonance at 17.6 T. J Cardiovasc Magn Reson 2019; 21:64. [PMID: 31610777 PMCID: PMC6792269 DOI: 10.1186/s12968-019-0566-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 07/23/2019] [Indexed: 11/10/2022] Open
Abstract
PURPOSE 4D flow cardiovascular magnetic resonance (CMR) and the assessment of wall shear stress (WSS) are non-invasive tools to study cardiovascular risks in vivo. Major limitations of conventional triggered methods are the long measurement times needed for high-resolution data sets and the necessity of stable electrocardiographic (ECG) triggering. In this work an ECG-free retrospectively synchronized method is presented that enables accelerated high-resolution measurements of 4D flow and WSS in the aortic arch of mice. METHODS 4D flow and WSS were measured in the aortic arch of 12-week-old wildtype C57BL/6 J mice (n = 7) with a radial 4D-phase-contrast (PC)-CMR sequence, which was validated in a flow phantom. Cardiac and respiratory motion signals were extracted from the radial CMR signal and were used for the reconstruction of 4D-flow data. Rigid motion correction and a first order B0 correction was used to improve the robustness of magnitude and velocity data. The aortic lumen was segmented semi-automatically. Temporally averaged and time-resolved WSS and oscillatory shear index (OSI) were calculated from the spatial velocity gradients at the lumen surface at 14 locations along the aortic arch. Reproducibility was tested in 3 animals and the influence of subsampling was investigated. RESULTS Volume flow, cross-sectional areas, WSS and the OSI were determined in a measurement time of only 32 min. Longitudinal and circumferential WSS and radial stress were assessed at 14 analysis planes along the aortic arch. The average longitudinal, circumferential and radial stress values were 1.52 ± 0.29 N/m2, 0.28 ± 0.24 N/m2 and - 0.21 ± 0.19 N/m2, respectively. Good reproducibility of WSS values was observed. CONCLUSION This work presents a robust measurement of 4D flow and WSS in mice without the need of ECG trigger signals. The retrospective approach provides fast flow quantification within 35 min and a flexible reconstruction framework.
Collapse
Affiliation(s)
- Patrick Winter
- Experimental Physiks V, University of Würzburg, Am Hubland, 97074 Würzburg, Germany
- Medical Clinic and Policlinic I, University Wuerzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Kristina Andelovic
- Experimental Physiks V, University of Würzburg, Am Hubland, 97074 Würzburg, Germany
- Medical Clinic and Policlinic I, University Wuerzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
- Institute for Experimental Biomedicine, University Hospital Würzburg, Josef-Schneider-Straße 2, 97080 Würzburg, Germany
| | - Thomas Kampf
- Experimental Physiks V, University of Würzburg, Am Hubland, 97074 Würzburg, Germany
- Diagnostic and Interventional Neuroradiology, University Hospital Würzburg, Josef-Schneider-Straße 11, 97080 Würzburg, Germany
| | | | - Julius Heidenreich
- Medical Clinic and Policlinic I, University Wuerzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Alma Zernecke
- Institute for Experimental Biomedicine, University Hospital Würzburg, Josef-Schneider-Straße 2, 97080 Würzburg, Germany
| | - Wolfgang Rudolf Bauer
- Medical Clinic and Policlinic I, University Wuerzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Peter Michael Jakob
- Experimental Physiks V, University of Würzburg, Am Hubland, 97074 Würzburg, Germany
| | - Volker Herold
- Experimental Physiks V, University of Würzburg, Am Hubland, 97074 Würzburg, Germany
| |
Collapse
|
22
|
PIEZO1 and TRPV4, which Are Distinct Mechano-Sensors in the Osteoblastic MC3T3-E1 Cells, Modify Cell-Proliferation. Int J Mol Sci 2019; 20:ijms20194960. [PMID: 31597314 PMCID: PMC6801562 DOI: 10.3390/ijms20194960] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 10/04/2019] [Accepted: 10/05/2019] [Indexed: 02/07/2023] Open
Abstract
Mechanical-loading and unloading can modify osteoblast functioning. Ca2+ signaling is one of the earliest events in osteoblasts to induce a mechanical stimulus, thereby demonstrating the importance of the underlying mechanical sensors for the sensation. Here, we examined the mechano-sensitive channels PIEZO1 and TRPV4 were involved in the process of mechano-sensation in the osteoblastic MC3T3-E1 cells. The analysis of mRNA expression revealed a high expression of Piezo1 and Trpv4 in these cells. We also found that a PIEZO1 agonist, Yoda1, induced Ca2+ response and activated cationic currents in these cells. Ca2+ response was elicited when mechanical stimulation (MS), with shear stress, was induced by fluid flow in the MC3T3-E1 cells. Gene knockdown of Piezo1 in the MC3T3-E1 cells, by transfection with siPiezo1, inhibited the Yoda1-induced response, but failed to inhibit the MS-induced response. When MC3T3-E1 cells were transfected with siTrpv4, the MS-induced response was abolished and Yoda1 response was attenuated. Moreover, the MS-induced response was inhibited by a TRPV4 antagonist HC-067047 (HC). Yoda1 response was also inhibited by HC in MC3T3-E1 cells and HEK cells, expressing both PIEZO1 and TRPV4. Meanwhile, the activation of PIEZO1 and TRPV4 reduced the proliferation of MC3T3-E1, which was reversed by knockdown of PIEZO1, and TRPV4, respectively. In conclusion, TRPV4 and PIEZO1 are distinct mechano-sensors in the MC3T3-E1 cells. However, PIEZO1 and TRPV4 modify the proliferation of these cells, implying that PIEZO1 and TRPV4 may be functional in the osteoblastic mechano-transduction. Notably, it is also found that Yoda1 can induce TRPV4-dependent Ca2+ response, when both PIEZO1 and TRPV4 are highly expressed.
Collapse
|
23
|
Acuna A, Berman AG, Damen FW, Meyers BA, Adelsperger AR, Bayer KC, Brindise MC, Bungart B, Kiel AM, Morrison RA, Muskat JC, Wasilczuk KM, Wen Y, Zhang J, Zito P, Goergen CJ. Computational Fluid Dynamics of Vascular Disease in Animal Models. J Biomech Eng 2019; 140:2676341. [PMID: 29570754 DOI: 10.1115/1.4039678] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Indexed: 12/19/2022]
Abstract
Recent applications of computational fluid dynamics (CFD) applied to the cardiovascular system have demonstrated its power in investigating the impact of hemodynamics on disease initiation, progression, and treatment outcomes. Flow metrics such as pressure distributions, wall shear stresses (WSS), and blood velocity profiles can be quantified to provide insight into observed pathologies, assist with surgical planning, or even predict disease progression. While numerous studies have performed simulations on clinical human patient data, it often lacks prediagnosis information and can be subject to large intersubject variability, limiting the generalizability of findings. Thus, animal models are often used to identify and manipulate specific factors contributing to vascular disease because they provide a more controlled environment. In this review, we explore the use of CFD in animal models in recent studies to investigate the initiating mechanisms, progression, and intervention effects of various vascular diseases. The first section provides a brief overview of the CFD theory and tools that are commonly used to study blood flow. The following sections are separated by anatomical region, with the abdominal, thoracic, and cerebral areas specifically highlighted. We discuss the associated benefits and obstacles to performing CFD modeling in each location. Finally, we highlight animal CFD studies focusing on common surgical treatments, including arteriovenous fistulas (AVF) and pulmonary artery grafts. The studies included in this review demonstrate the value of combining CFD with animal imaging and should encourage further research to optimize and expand upon these techniques for the study of vascular disease.
Collapse
Affiliation(s)
- Andrea Acuna
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Alycia G Berman
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Frederick W Damen
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Brett A Meyers
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN 47907 e-mail:
| | - Amelia R Adelsperger
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Kelsey C Bayer
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Melissa C Brindise
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN 47907 e-mail:
| | - Brittani Bungart
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Alexander M Kiel
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Rachel A Morrison
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Joseph C Muskat
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Kelsey M Wasilczuk
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Yi Wen
- Department of Agricultural and Biological Engineering, Purdue University, 225 South University Street, West Lafayette, IN 47907 e-mail:
| | - Jiacheng Zhang
- School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN 47907 e-mail:
| | - Patrick Zito
- Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| | - Craig J Goergen
- ASME Membership Bioengineering Division, Weldon School of Biomedical Engineering, Purdue University, 206 S. Martin Jischke Drive, West Lafayette, IN 47907 e-mail:
| |
Collapse
|
24
|
Spronck B, Humphrey JD. Arterial Stiffness: Different Metrics, Different Meanings. J Biomech Eng 2019; 141:091004. [PMID: 30985880 PMCID: PMC6808013 DOI: 10.1115/1.4043486] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 03/25/2019] [Indexed: 12/18/2022]
Abstract
Findings from basic science and clinical studies agree that arterial stiffness is fundamental to both the mechanobiology and the biomechanics that dictate vascular health and disease. There is, therefore, an appropriately growing literature on arterial stiffness. Perusal of the literature reveals, however, that many different methods and metrics are used to quantify arterial stiffness, and reported values often differ by orders of magnitude and have different meanings. Without clear definitions and an understanding of possible inter-relations therein, it is increasingly difficult to integrate results from the literature to glean true understanding. In this paper, we briefly review methods that are used to infer values of arterial stiffness that span studies on isolated cells, excised intact vessels, and clinical assessments. We highlight similarities and differences and identify a single theoretical approach that can be used across scales and applications and thus could help to unify future results. We conclude by emphasizing the need to move toward a synthesis of many disparate reports, for only in this way will we be able to move from our current fragmented understanding to a true appreciation of how vascular cells maintain, remodel, or repair the arteries that are fundamental to cardiovascular properties and function.
Collapse
Affiliation(s)
- B. Spronck
- Department of Biomedical Engineering,
Yale University,
New Haven, CT 06520
| | - J. D. Humphrey
- Fellow ASME
Department of Biomedical Engineering,
Yale University,
New Haven, CT 06520;
Vascular Biology and Therapeutics Program,
Yale School of Medicine,
New Haven, CT 06520
e-mail:
| |
Collapse
|
25
|
Crouch AC, Cao AA, Scheven UM, Greve JM. In Vivo MRI Assessment of Blood Flow in Arteries and Veins from Head-to-Toe Across Age and Sex in C57BL/6 Mice. Ann Biomed Eng 2019; 48:329-341. [PMID: 31456089 DOI: 10.1007/s10439-019-02350-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 08/20/2019] [Indexed: 10/26/2022]
Abstract
Although widely used as a preclinical model for studying cardiovascular diseases, there is a scarcity of in vivo hemodynamic measurements of the naïve murine system in multiple arterial and venous locations, from head-to-toe, and across sex and age. The purpose of this study is to quantify cardiovascular hemodynamics in mice at different locations along the vascular tree while evaluating the effects of sex and age. Male and female, adult and aged mice were anesthetized and underwent magnetic resonance imaging. Data were acquired from four co-localized vessel pairs (carotid/jugular, suprarenal and infrarenal aorta/inferior vena cava (IVC), femoral artery/vein) at normothermia (core temperature 37 ± 0.2 °C). Influences of age and sex on average velocity differ by location in arteries. Average arterial velocities, when plotted as a function of distance from the heart, decrease nearly linearly from the suprarenal aorta to the femoral artery (adult and aged males: - 0.33 ± 0.13, R2 = 0.87; - 0.43 ± 0.10, R2 = 0.95; adult and aged females: - 0.23 ± 0.07, R2 = 0.91; - 0.23 ± 0.02, R2 = 0.99). Average velocity of aged males and average volumetric flow of aged males and females tended to be larger compared to adult comparators. With cardiovascular disease as the leading cause of death and with the implications of cardiovascular hemodynamics as important biomarkers for health and disease, this work provides a foundation for sex and age comparisons in pathophysiology by collecting and analyzing hemodynamic data for the healthy murine arterial and venous system from head-to-toe, across sex and age.
Collapse
Affiliation(s)
- A Colleen Crouch
- Mechanical Engineering, University of Michigan, 1049 Bonisteel Interdisciplinary Research Building, 2360 Bonisteel Boulevard, Ann Arbor, MI, 48109-2099, USA.
| | - Amos A Cao
- Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Ulrich M Scheven
- Mechanical Engineering, University of Michigan, 1049 Bonisteel Interdisciplinary Research Building, 2360 Bonisteel Boulevard, Ann Arbor, MI, 48109-2099, USA
| | - Joan M Greve
- Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
26
|
Jiang K, Ferguson CM, Abumoawad A, Saad A, Textor SC, Lerman LO. A modified two-compartment model for measurement of renal function using dynamic contrast-enhanced computed tomography. PLoS One 2019; 14:e0219605. [PMID: 31291361 PMCID: PMC6619810 DOI: 10.1371/journal.pone.0219605] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 06/27/2019] [Indexed: 12/14/2022] Open
Abstract
Objectives To validate and adapt a modified two-compartment model, originally developed for magnetic resonance imaging, for measuring human single-kidney glomerular filtration rate (GFR) and perfusion using dynamic contrast-enhanced computed tomography (DCE-CT). Methods This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Thirty-eight patients with essential hypertension (EH, n = 13) or atherosclerotic renal artery stenosis (ARAS, n = 25) underwent renal DCE-CT for GFR and perfusion measurement using a modified two-compartment model. Iothalamate clearance was used to measure reference total GFR, which was apportioned into single-kidney GFR by renal blood flow. Renal perfusion was also calculated using a conventional deconvolution algorithm. Validation of GFR and perfusion and inter-observer reproducibility, were conducted by using the Pearson correlation and Bland-Altman analysis. Results Both the two-compartment model and iothalamate clearance detected in ARAS patients lower GFR in the stenotic compared to the contralateral and EH kidneys. GFRs measured by DCE-CT and iothalamate clearance showed a close match (r = 0.94, P<0.001, and mean difference 2.5±12.2mL/min). Inter-observer bias and variation in model-derived GFR (r = 0.97, P<0.001; mean difference, 0.3±7.7mL/min) were minimal. Renal perfusion by deconvolution agreed well with that by the compartment model when the blood transit delay from abdominal aorta to kidney was negligible. Conclusion The proposed two-compartment model faithfully depicts contrast dynamics using DCE-CT and may provide a reliable tool for measuring human single-kidney GFR and perfusion.
Collapse
Affiliation(s)
- Kai Jiang
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Christopher M. Ferguson
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Abdelrhman Abumoawad
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Ahmed Saad
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Stephen C. Textor
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
| | - Lilach O. Lerman
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, United States of America
- * E-mail:
| |
Collapse
|
27
|
PolNet: A Tool to Quantify Network-Level Cell Polarity and Blood Flow in Vascular Remodeling. Biophys J 2019; 114:2052-2058. [PMID: 29742399 PMCID: PMC5961748 DOI: 10.1016/j.bpj.2018.03.032] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 02/28/2018] [Accepted: 03/14/2018] [Indexed: 11/21/2022] Open
Abstract
In this article, we present PolNet, an open-source software tool for the study of blood flow and cell-level biological activity during vessel morphogenesis. We provide an image acquisition, segmentation, and analysis protocol to quantify endothelial cell polarity in entire in vivo vascular networks. In combination, we use computational fluid dynamics to characterize the hemodynamics of the vascular networks under study. The tool enables, to our knowledge for the first time, a network-level analysis of polarity and flow for individual endothelial cells. To date, PolNet has proven invaluable for the study of endothelial cell polarization and migration during vascular patterning, as demonstrated by two recent publications. Additionally, the tool can be easily extended to correlate blood flow with other experimental observations at the cellular/molecular level. We release the source code of our tool under the Lesser General Public License.
Collapse
|
28
|
Seymour RS, Hu Q, Snelling EP, White CR. Interspecific scaling of blood flow rates and arterial sizes in mammals. ACTA ACUST UNITED AC 2019; 222:jeb.199554. [PMID: 30877224 DOI: 10.1242/jeb.199554] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Accepted: 03/07/2019] [Indexed: 01/16/2023]
Abstract
This meta-study investigated the relationships between blood flow rate (Q̇; cm3 s-1), wall shear stress (τw; dyn cm-2) and lumen radius (r i; cm) in 20 named systemic arteries of nine species of mammals, ranging in mass from 23 g mice to 652 kg cows, at rest. In the dataset, derived from 50 studies, lumen radius varied between 3.7 µm in a cremaster artery of a rat and 11.2 mm in the aorta of a human. The 92 logged data points of [Formula: see text] and r i are described by a single second-order polynomial curve with the equation: [Formula: see text] The slope of the curve increased from approximately 2 in the largest arteries to approximately 3 in the smallest ones. Thus, da Vinci's rule ([Formula: see text]) applies to the main arteries and Murray's law ([Formula: see text]) applies to the microcirculation. A subset of the data, comprising only cephalic arteries in which [Formula: see text] is fairly constant, yielded the allometric power equation: [Formula: see text] These empirical equations allow calculation of resting perfusion rates from arterial lumen size alone, without reliance on theoretical models or assumptions on the scaling of wall shear stress in relation to body mass. As expected, [Formula: see text] of individual named arteries is strongly affected by body mass; however, [Formula: see text] of the common carotid artery from six species (mouse to horse) is also sensitive to differences in whole-body basal metabolic rate, independent of the effect of body mass.
Collapse
Affiliation(s)
- Roger S Seymour
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA 5005, Australia
| | - Qiaohui Hu
- School of Biological Sciences, Faculty of Sciences, University of Adelaide, Adelaide, SA 5005, Australia
| | - Edward P Snelling
- Department of Anatomy and Physiology, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, Gauteng 0110, South Africa.,Brain Function Research Group, School of Physiology, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, Gauteng 2193, South Africa
| | - Craig R White
- Centre for Geometric Biology, School of Biological Sciences, Faculty of Science, Monash University, Clayton, VIC 3800, Australia
| |
Collapse
|
29
|
Harrington AR, Kuzawa CW, Boyer DM. Carotid foramen size in the human skull tracks developmental changes in cerebral blood flow and brain metabolism. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2019; 169:161-169. [PMID: 30821356 DOI: 10.1002/ajpa.23809] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 01/30/2019] [Accepted: 02/13/2019] [Indexed: 11/08/2022]
Abstract
OBJECTIVES In humans, neuronal processes related to brain development elevate the metabolic rate of brain tissue relative to the body during early childhood. This phenomenon has been hypothesized to contribute to slow somatic growth in preadolescent Homo sapiens. The uncoupling of the brain's metabolic rate from brain size during development complicates the study of the evolutionary emergence of these traits in the fossil record. Here, we extend a method previously developed to predict interspecific differences in cerebral blood flow (a correlate of cerebral glucose use) to predict ontogenetic changes in human brain metabolism. MATERIALS AND METHODS Radii of the carotid foramen from an ontogenetic series of modern human crania were used to predict blood flow rates through the internal carotid arteries (ICA), which were compared to empirically measured ICA flow and brain metabolism values. RESULTS Predictions of both absolute ICA blood flow rates and perfusion (ICA blood flow rates relative to brain size) generally match measured values in infancy and childhood. Maximum predicted ICA blood flow rates and perfusion were found to occur between ages 5 and 8, which roughly correspond to the age of maximum measured ICA blood flow rate and absolute and brain mass-specific rate of whole brain glucose uptake. DISCUSSION These findings suggest that, during human growth and development, the size of the carotid foramen corresponds well to blood flow requirements through the ICA, and the method tested here may provide new opportunities for studying developmental changes in brain metabolism using osteological samples, including fossil hominins.
Collapse
Affiliation(s)
- Arianna R Harrington
- Department of Evolutionary Anthropology, Duke University, Durham, North Carolina
| | | | - Doug M Boyer
- Department of Evolutionary Anthropology, Duke University, Durham, North Carolina
| |
Collapse
|
30
|
Cuomo F, Ferruzzi J, Agarwal P, Li C, Zhuang ZW, Humphrey JD, Figueroa CA. Sex-dependent differences in central artery haemodynamics in normal and fibulin-5 deficient mice: implications for ageing. Proc Math Phys Eng Sci 2019; 475:20180076. [PMID: 30760948 PMCID: PMC6364598 DOI: 10.1098/rspa.2018.0076] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 11/26/2018] [Indexed: 12/17/2022] Open
Abstract
Mouse models provide unique opportunities to study vascular disease, but they demand increased experimental and computational resolution. We describe a workflow for combining in vivo and in vitro biomechanical data to build mouse-specific computational models of the central vasculature including regional variations in biaxial wall stiffness, thickness and perivascular support. These fluid-solid interaction models are informed by micro-computed tomography imaging and in vivo ultrasound and pressure measurements, and include mouse-specific inflow and outflow boundary conditions. Hence, the model can capture three-dimensional unsteady flows and pulse wave characteristics. The utility of this experimental-computational approach is illustrated by comparing central artery biomechanics in adult wild-type and fibulin-5 deficient mice, a model of early vascular ageing. Findings are also examined as a function of sex. Computational results compare well with measurements and data available in the literature and suggest that pulse wave velocity, a spatially integrated measure of arterial stiffness, does not reflect well the presence of regional differences in stiffening, particularly those manifested in male versus female mice. Modelling results are also useful for comparing quantities that are difficult to measure or infer experimentally, including local pulse pressures at the renal arteries and characteristics of the peripheral vascular bed that may differ with disease.
Collapse
Affiliation(s)
- Federica Cuomo
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Jacopo Ferruzzi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Pradyumn Agarwal
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Chen Li
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Zhen W. Zhuang
- Translational Research Imaging Center, Yale University, New Haven, CT, USA
| | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Vascular Biology and Therapeutics Program, Yale University, New Haven, CT, USA
| | - C. Alberto Figueroa
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Surgery, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
31
|
Korneva A, Zilberberg L, Rifkin DB, Humphrey JD, Bellini C. Absence of LTBP-3 attenuates the aneurysmal phenotype but not spinal effects on the aorta in Marfan syndrome. Biomech Model Mechanobiol 2018; 18:261-273. [PMID: 30306291 DOI: 10.1007/s10237-018-1080-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Accepted: 09/18/2018] [Indexed: 02/07/2023]
Abstract
Fibrillin-1 is an elastin-associated glycoprotein that contributes to the long-term fatigue resistance of elastic fibers as well as to the bioavailability of transforming growth factor-beta (TGFβ) in arteries. Altered TGFβ bioavailability and/or signaling have been implicated in aneurysm development in Marfan syndrome (MFS), a multi-system condition resulting from mutations to the gene that encodes fibrillin-1. We recently showed that the absence of the latent transforming growth factor-beta binding protein-3 (LTBP-3) in fibrillin-1-deficient mice attenuates the fragmentation of elastic fibers and focal dilatations that are characteristic of aortic root aneurysms in MFS mice, at least to 12 weeks of age. Here, we show further that the absence of LTBP-3 in this MFS mouse model improves the circumferential mechanical properties of the thoracic aorta, which appears to be fundamental in preventing or significantly delaying aneurysm development. Yet, a spinal deformity either remains or is exacerbated in the absence of LTBP-3 and seems to adversely affect the axial mechanical properties of the thoracic aorta, thus decreasing overall vascular function despite the absence of aneurysmal dilatation. Importantly, because of the smaller size of mice lacking LTBP-3, allometric scaling facilitates proper interpretation of aortic dimensions and thus the clinical phenotype. While this study demonstrates that LTBP-3/TGFβ directly affects the biomechanical function of the thoracic aorta, it highlights that spinal deformities in MFS might indirectly and adversely affect the overall aortic phenotype. There is a need, therefore, to consider together the vascular and skeletal effects in this syndromic disease.
Collapse
Affiliation(s)
- A Korneva
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - L Zilberberg
- Departments of Cell Biology and Medicine, New York University, New York, NY, USA
| | - D B Rifkin
- Departments of Cell Biology and Medicine, New York University, New York, NY, USA
| | - J D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA
| | - C Bellini
- Department of Bioengineering, Northeastern University, Boston, MA, USA.
| |
Collapse
|
32
|
Abstract
OBJECTIVES The aim of this study was to demonstrate a new clinically translatable ultrasound molecular imaging approach, modulated acoustic radiation force-based imaging, which is capable of rapid and reliable detection of inflammation as validated in mouse abdominal aorta. MATERIALS AND METHODS Animal studies were approved by the Institutional Animal Care and Use Committee at the University of Virginia. C57BL/6 mice stimulated with tumor necrosis factor α, or fed with a high-fat diet, were used as inflammation (MInflammation) and diet-induced obesity (DIO) (MDIO) models, respectively. C57BL/6 mice, not exposed to tumor necrosis factor α or DIO, were used as controls (MNormal). P-selectin-targeted (MBP-selectin), vascular cell adhesion molecule (VCAM)-1-targeted (MBVCAM-1), and isotype control (MBControl) microbubbles were synthesized by conjugating anti-P-selectin, anti-VCAM-1, and isotype control antibodies to microbubbles, respectively. The abdominal aortas were imaged for 180 seconds during a constant infusion of microbubbles. A parameter, residual-to-saturation ratio (RSR), was used to assess P-selectin and VCAM-1. Statistical analysis was performed with the Student t test. RESULTS For the inflammation model, RSR of the MInflammation + MBP-selectin group was significantly higher (40.9%, P < 0.0005) than other groups. For the DIO model, RSR of the MDIO + MBVCAM-1 group was significantly higher (60.0%, P < 0.0005) than other groups. Immunohistochemistry staining of the abdominal aorta confirmed the expression of P-selectin and VCAM-1. CONCLUSIONS A statistically significant assessment of P-selectin and VCAM-1 in mouse abdominal aorta was achieved. This technique yields progress toward rapid targeted molecular imaging in large blood vessels and thus has the potential for early diagnosis, treatment selection, and risk stratification of atherosclerosis.
Collapse
|
33
|
Qi YX, Han Y, Jiang ZL. Mechanobiology and Vascular Remodeling: From Membrane to Nucleus. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1097:69-82. [PMID: 30315540 DOI: 10.1007/978-3-319-96445-4_4] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Vascular endothelial cells (ECs) and smooth muscle cells (VSMCs) are constantly exposed to hemodynamic forces in vivo, including flow shear stress and cyclic stretch caused by the blood flow. Numerous researches revealed that during various cardiovascular diseases such as atherosclerosis, hypertension, and vein graft, abnormal (pathological) mechanical forces play crucial roles in the dysfunction of ECs and VSMCs, which is the fundamental process during both vascular homeostasis and remodeling. Hemodynamic forces trigger several membrane molecules and structures, such as integrin, ion channel, primary cilia, etc., and induce the cascade reaction processes through complicated cellular signaling networks. Recent researches suggest that nuclear envelope proteins act as the functional homology of molecules on the membrane, are important mechanosensitive molecules which modulate chromatin location and gene transcription, and subsequently regulate cellular functions. However, the studies on the roles of nucleus in the mechanotransduction process are still at the beginning. Here, based on the recent researches, we focused on the nuclear envelope proteins and discussed the roles of pathological hemodynamic forces in vascular remodeling. It may provide new insight into understanding the molecular mechanism of vascular physiological homeostasis and pathophysiological remodeling and may help to develop hemodynamic-based strategies for the prevention and management of vascular diseases.
Collapse
Affiliation(s)
- Ying-Xin Qi
- Institute of Mechanobiology and Medical Engineering, School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, Shanghai, China.
| | - Yue Han
- Institute of Mechanobiology and Medical Engineering, School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, Shanghai, China
| | - Zong-Lai Jiang
- Institute of Mechanobiology and Medical Engineering, School of Life Sciences and Biotechnology, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
34
|
Phillips EH, Chang MS, Gorman S, Qureshi HJ, Ejendal KFK, Kinzer-Ursem TL, Blaize AN, Goergen CJ. Angiotensin II Infusion Does Not Cause Abdominal Aortic Aneurysms in Apolipoprotein E-Deficient Rats. J Vasc Res 2017; 55:1-12. [PMID: 29166645 DOI: 10.1159/000484086] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2017] [Accepted: 10/07/2017] [Indexed: 12/31/2022] Open
Abstract
The apolipoprotein E-deficient (apoE-/-) mouse model has advanced our understanding of cardiovascular disease mechanisms and experimental therapeutics. This spontaneous model recapitulates aspects of human atherosclerosis, and allows for the development of dissecting abdominal aortic aneurysms (AAAs) when combined with angiotensin II. We characterized apoE-/- rats and hypothesized that, similar to mice, they would develop dissecting AAAs. We created rats with a 16-bp deletion of the apoE gene using transcription activator-like effector nucleases. We imaged the suprarenal aorta for 28 days after implantation of miniosmotic pumps that infuse angiotensin II (AngII, 200 ng/kg/min). Blood pressure (BP), serum lipids and lipoproteins, and histology were also analyzed. These rats did not develop pathological aortic dissection, but we did observe a decrease in circumferential cyclic strain, a rise in BP, and microstructural changes in the aortic medial layer. We also measured increased serum lipids with and without administration of a high-fat diet, but did not detect atherosclerotic plaques. Chronic infusion of AngII did not lead to the formation of dissecting AAAs or atherosclerosis in the rats used in this study. While reduced amounts of atherosclerosis may explain this resistance to dissecting aneurysms, further investigation is needed to fully characterize species-specific differences.
Collapse
Affiliation(s)
- Evan H Phillips
- Weldon School of Biomedical Engineering, West Lafayette, IN, USA
| | | | | | | | | | | | | | | |
Collapse
|
35
|
In vivo characterization of the murine venous system before and during dobutamine stimulation: implications for preclinical models of venous disease. Ann Anat 2017; 214:43-52. [DOI: 10.1016/j.aanat.2017.08.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2017] [Revised: 07/04/2017] [Accepted: 08/14/2017] [Indexed: 12/12/2022]
|
36
|
Rode B, Shi J, Endesh N, Drinkhill MJ, Webster PJ, Lotteau SJ, Bailey MA, Yuldasheva NY, Ludlow MJ, Cubbon RM, Li J, Futers TS, Morley L, Gaunt HJ, Marszalek K, Viswambharan H, Cuthbertson K, Baxter PD, Foster R, Sukumar P, Weightman A, Calaghan SC, Wheatcroft SB, Kearney MT, Beech DJ. Piezo1 channels sense whole body physical activity to reset cardiovascular homeostasis and enhance performance. Nat Commun 2017; 8:350. [PMID: 28839146 PMCID: PMC5571199 DOI: 10.1038/s41467-017-00429-3] [Citation(s) in RCA: 165] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2017] [Accepted: 06/20/2017] [Indexed: 01/24/2023] Open
Abstract
Mammalian biology adapts to physical activity but the molecular mechanisms sensing the activity remain enigmatic. Recent studies have revealed how Piezo1 protein senses mechanical force to enable vascular development. Here, we address Piezo1 in adult endothelium, the major control site in physical activity. Mice without endothelial Piezo1 lack obvious phenotype but close inspection reveals a specific effect on endothelium-dependent relaxation in mesenteric resistance artery. Strikingly, the Piezo1 is required for elevated blood pressure during whole body physical activity but not blood pressure during inactivity. Piezo1 is responsible for flow-sensitive non-inactivating non-selective cationic channels which depolarize the membrane potential. As fluid flow increases, depolarization increases to activate voltage-gated Ca2+ channels in the adjacent vascular smooth muscle cells, causing vasoconstriction. Physical performance is compromised in mice which lack endothelial Piezo1 and there is weight loss after sustained activity. The data suggest that Piezo1 channels sense physical activity to advantageously reset vascular control.The mechanisms that regulate the body's response to exercise are poorly understood. Here, Rode et al. show that the mechanically activated cation channel Piezo1 is a molecular sensor of physical exercise in the endothelium that triggers endothelial communication to mesenteric vessel muscle cells, leading to vasoconstriction.
Collapse
Affiliation(s)
- Baptiste Rode
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Jian Shi
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Naima Endesh
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | | | - Peter J Webster
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Sabine J Lotteau
- School of Biomedical Sciences, University of Leeds, Leeds, LS2 9JT, UK
| | - Marc A Bailey
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | | | | | | | - Jing Li
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - T Simon Futers
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Lara Morley
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Hannah J Gaunt
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | | | | | | | - Paul D Baxter
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Richard Foster
- School of Chemistry, University of Leeds, Leeds, LS2 9JT, UK
| | | | - Andrew Weightman
- School of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester, M13 9PL, UK
| | - Sarah C Calaghan
- School of Biomedical Sciences, University of Leeds, Leeds, LS2 9JT, UK
| | | | - Mark T Kearney
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - David J Beech
- Schools of Medicine, University of Leeds, Leeds, LS2 9JT, UK.
| |
Collapse
|
37
|
Thrombopoiesis is spatially regulated by the bone marrow vasculature. Nat Commun 2017; 8:127. [PMID: 28743899 PMCID: PMC5527048 DOI: 10.1038/s41467-017-00201-7] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 06/09/2017] [Indexed: 01/12/2023] Open
Abstract
In mammals, megakaryocytes (MKs) in the bone marrow (BM) produce blood platelets, required for hemostasis and thrombosis. MKs originate from hematopoietic stem cells and are thought to migrate from an endosteal niche towards the vascular sinusoids during their maturation. Through imaging of MKs in the intact BM, here we show that MKs can be found within the entire BM, without a bias towards bone-distant regions. By combining in vivo two-photon microscopy and in situ light-sheet fluorescence microscopy with computational simulations, we reveal surprisingly slow MK migration, limited intervascular space, and a vessel-biased MK pool. These data challenge the current thrombopoiesis model of MK migration and support a modified model, where MKs at sinusoids are replenished by sinusoidal precursors rather than cells from a distant periostic niche. As MKs do not need to migrate to reach the vessel, therapies to increase MK numbers might be sufficient to raise platelet counts.Megakaryocyte maturation is thought to occur as the cells migrate from a vessel-distant (endosteal) niche to the vessel within the bone. Here, the authors show that megakaryocytes represent largely sessile cells in close contact with the vasculature and homogeneously distributed in the bone marrow.
Collapse
|
38
|
van Haaften EE, Bouten CVC, Kurniawan NA. Vascular Mechanobiology: Towards Control of In Situ Regeneration. Cells 2017; 6:E19. [PMID: 28671618 PMCID: PMC5617965 DOI: 10.3390/cells6030019] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2017] [Revised: 06/16/2017] [Accepted: 06/23/2017] [Indexed: 01/08/2023] Open
Abstract
The paradigm of regenerative medicine has recently shifted from in vitro to in situ tissue engineering: implanting a cell-free, biodegradable, off-the-shelf available scaffold and inducing the development of functional tissue by utilizing the regenerative potential of the body itself. This approach offers a prospect of not only alleviating the clinical demand for autologous vessels but also circumventing the current challenges with synthetic grafts. In order to move towards a hypothesis-driven engineering approach, we review three crucial aspects that need to be taken into account when regenerating vessels: (1) the structure-function relation for attaining mechanical homeostasis of vascular tissues, (2) the environmental cues governing cell function, and (3) the available experimental platforms to test instructive scaffolds for in situ tissue engineering. The understanding of cellular responses to environmental cues leads to the development of computational models to predict tissue formation and maturation, which are validated using experimental platforms recapitulating the (patho)physiological micro-environment. With the current advances, a progressive shift is anticipated towards a rational and effective approach of building instructive scaffolds for in situ vascular tissue regeneration.
Collapse
Affiliation(s)
- Eline E van Haaften
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
- Institute for Complex Molecular Systems, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
| | - Carlijn V C Bouten
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
- Institute for Complex Molecular Systems, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
| | - Nicholas A Kurniawan
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
- Institute for Complex Molecular Systems, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
| |
Collapse
|
39
|
Phillips EH, Di Achille P, Bersi MR, Humphrey JD, Goergen CJ. Multi-Modality Imaging Enables Detailed Hemodynamic Simulations in Dissecting Aneurysms in Mice. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1297-1305. [PMID: 28186882 PMCID: PMC5505237 DOI: 10.1109/tmi.2017.2664799] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
A multi-modality imaging-based modeling approach was used to study complex unsteady hemodynamics and lesion growth in a dissecting abdominal aortic aneurysm model. We combined in vivo ultrasound (geometry and flow) and in vitro optical coherence tomography(OCT) (geometry) to obtain the high resolution needed to construct detailed hemodynamic simulations over large portions of the murine vasculature, which include fine geometric complexities. We illustrate this approach for a spectrum of dissecting abdominal aortic aneurysms induced in male apolipoprotein E-null mice by high-dose angiotensin II infusion. In vivo morphological and hemodynamic data provide information on volumetric lesion growth and changes in blood flow dynamics, respectively, occurring from the day of initial aortic expansion. We validated the associated computational models by comparing results on time-varying outlet flows and vortical structures within the lesions. Three out of four lesions exhibited abrupt formation of thrombus, though different in size. We determined that a lesion without thrombus formed with a thickened vessel wall, which was resolvable by OCT and histology. We attribute differences in final sizes and compositions of these lesions to the different computed flow and vortical structures we obtained in our mouse-specific fluid dynamic models. Differences in morphology and hemodynamics play crucial roles in determining the evolution of dissecting abdominal aortic aneurysms. Coupled high resolution in vivo and in vitro imaging approaches provide much-improved geometric models for hemodynamic simulations. Our imaging-based computational findings suggest a link between perturbations in hemodynamic metrics and aneurysmal disease heterogeneity.
Collapse
|
40
|
Chen Z, Yu H, Shi Y, Zhu M, Wang Y, Hu X, Zhang Y, Chang Y, Xu M, Gao W. Vascular Remodelling Relates to an Elevated Oscillatory Shear Index and Relative Residence Time in Spontaneously Hypertensive Rats. Sci Rep 2017; 7:2007. [PMID: 28515420 PMCID: PMC5435712 DOI: 10.1038/s41598-017-01906-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Accepted: 04/03/2017] [Indexed: 01/25/2023] Open
Abstract
Haemodynamic disorders are common clinical findings in hypertension and lead to adverse cardiovascular events. However, the haemodynamic conditions in hypertension models are poorly understood. This study aimed to observe the characteristics of haemodynamics in spontaneously hypertensive rats (SHRs) and antihypertensive-treated SHRs. Twenty-four adult male SHRs and Wistar-Kyoto rats (WKYs) were randomly divided into four groups and treated for 7 days as follows: WKY-CON (WKYs + saline), WKY-NIF (WKYs + nifedipine, 50 mg/kg/day), SHR-CON (SHRs + saline), and SHR-NIF (SHRs + nifedipine). Aortic computational fluid dynamics (CFD) models were simulated to obtain the haemodynamic parameters. We found that in the hypertensive (SHR-CON) and blood pressure-controlled (SHR-NIF) groups, the oscillatory shear index (OSI) and relative residence time (RRT), which are key haemodynamics indices, were markedly elevated. Furthermore, there was a correlation between both the elevated OSI and RRT with the vascular wall thickening in regions near the inner wall of the aortic arch. Our research demonstrates that haemodynamics remains disturbed even if the blood pressure is normalized. In addition, vascular remodelling may play an important role in maintaining elevated OSI and RRT values.
Collapse
Affiliation(s)
- Zhiyan Chen
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China
| | - Haiyi Yu
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China
| | - Yue Shi
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China
| | - Minjia Zhu
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China
| | - Yueshen Wang
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China
| | - Xi Hu
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China
| | - Youyi Zhang
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China
| | - Yu Chang
- College of Life Science and Bioengineering, Beijing University of Technology, Beijing, 100124, China.
| | - Ming Xu
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China.
| | - Wei Gao
- Department of Cardiology, Peking University Third Hospital and Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Sciences, Ministry of Education and Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing, 100191, China.
| |
Collapse
|
41
|
Nemeth N, Sogor V, Kiss F, Ulker P. Interspecies diversity of erythrocyte mechanical stability at various combinations in magnitude and duration of shear stress, and osmolality. Clin Hemorheol Microcirc 2017; 63:381-398. [PMID: 26890103 DOI: 10.3233/ch-152031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
We hypothesized that the results of red blood cell mechanical stability test show interspecies differences. The comparative investigations were performed on blood samples obtained from rats, beagle dogs, pigs and healthy volunteers. Mechanical stress was applied in nine combinations: 30, 60 or 100 Pa shear stress for 100, 200 or 300 seconds. Generally, rat erythrocytes showed the highest capability of resistance. With the applied combinations of mechanical stress pig erythrocytes were the most sensitive. On human erythrocytes 60 Pa for 200 s was the minimum combination to result significant deformability deterioration. By increasing the magnitude and duration of the applied mechanical stress we experienced escalating deformability impairment in all species. 100 Pa shear stress for 300 seconds on human erythrocytes showed the largest deformability impairment. The mechanical stability test results were also dependent on osmolality. At hypoosmolar range (200 mOsmol/kg) the mechanical stress improved EI data mostly in rat and porcine blood. At higher osmolality (500 mOsmol/kg), the test did not show detectable difference, while in 250-300 mOsmol/kg range the differences were well observable. In summary, erythrocytes' capability of resistance against mechanical stress shows interspecies differences depending on the magnitude and duration of the applied stress, and on the osmolality.
Collapse
Affiliation(s)
- Norbert Nemeth
- Department of Operative Techniques and Surgical Research, Institute of Surgery, Faculty of Medicine, University of Debrecen, Hungary
| | - Viktoria Sogor
- Department of Operative Techniques and Surgical Research, Institute of Surgery, Faculty of Medicine, University of Debrecen, Hungary
| | - Ferenc Kiss
- Department of Operative Techniques and Surgical Research, Institute of Surgery, Faculty of Medicine, University of Debrecen, Hungary
| | - Pinar Ulker
- Department of Physiology, Akdeniz University Faculty of Medicine, Antalya, Turkey
| |
Collapse
|
42
|
Huo Y, Kassab GS. Scaling laws of coronary circulation in health and disease. J Biomech 2016; 49:2531-9. [DOI: 10.1016/j.jbiomech.2016.01.044] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2016] [Accepted: 01/28/2016] [Indexed: 02/07/2023]
|
43
|
De Wilde D, Trachet B, De Meyer G, Segers P. The influence of anesthesia and fluid-structure interaction on simulated shear stress patterns in the carotid bifurcation of mice. J Biomech 2016; 49:2741-2747. [PMID: 27342001 DOI: 10.1016/j.jbiomech.2016.06.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/04/2016] [Accepted: 06/07/2016] [Indexed: 01/04/2023]
Abstract
BACKGROUND Low and oscillatory wall shear stresses (WSS) near aortic bifurcations have been linked to the onset of atherosclerosis. In previous work, we calculated detailed WSS patterns in the carotid bifurcation of mice using a Fluid-structure interaction (FSI) approach. We subsequently fed the animals a high-fat diet and linked the results of the FSI simulations to those of atherosclerotic plaque location on a within-subject basis. However, these simulations were based on boundary conditions measured under anesthesia, while active mice might experience different hemodynamics. Moreover, the FSI technique for mouse-specific simulations is both time- and labor-intensive, and might be replaced by simpler and easier Computational Fluid Dynamics (CFD) simulations. The goal of the current work was (i) to compare WSS patterns based on anesthesia conditions to those representing active resting and exercising conditions; and (ii) to compare WSS patterns based on FSI simulations to those based on steady-state and transient CFD simulations. METHODS For each of the 3 computational techniques (steady state CFD, transient CFD, FSI) we performed 5 simulations: 1 for anesthesia, 2 for conscious resting conditions and 2 more for conscious active conditions. The inflow, pressure and heart rate were scaled according to representative in vivo measurements obtained from literature. RESULTS When normalized by the maximal shear stress value, shear stress patterns were similar for the 3 computational techniques. For all activity levels, steady state CFD led to an overestimation of WSS values, while FSI simulations yielded a clear increase in WSS reversal at the outer side of the sinus of the external carotid artery that was not visible in transient CFD-simulations. Furthermore, the FSI simulations in the highest locomotor activity state showed a flow recirculation zone in the external carotid artery that was not present under anesthesia. This recirculation went hand in hand with locally increased WSS reversal. CONCLUSIONS Our data show that FSI simulations are not necessary to obtain normalized WSS patterns, but indispensable to assess the oscillatory behavior of the WSS in mice. Flow recirculation and WSS reversal at the external carotid artery may occur during high locomotor activity while they are not present under anesthesia. These phenomena might thus influence plaque formation to a larger extent than what was previously assumed.
Collapse
Affiliation(s)
- David De Wilde
- IBiTech-bioMMeda, Ghent University-IMinds Medical IT, Ghent, Belgium
| | - Bram Trachet
- IBiTech-bioMMeda, Ghent University-IMinds Medical IT, Ghent, Belgium; Institute of Bioengineering, EPFL, Lausanne, Switzerland.
| | - Guido De Meyer
- Division of Physiopharmacology, University of Antwerp, Antwerp, Belgium
| | - Patrick Segers
- IBiTech-bioMMeda, Ghent University-IMinds Medical IT, Ghent, Belgium
| |
Collapse
|
44
|
Abstract
A review is presented of the physical principles governing the distribution of blood flow and blood pressure in the vascular system. The main factors involved are the pulsatile driving pressure generated by the heart, the flow characteristics of blood, and the geometric structure and mechanical properties of the vessels. The relationship between driving pressure and flow in a given vessel can be understood by considering the viscous and inertial forces acting on the blood. Depending on the vessel diameter and other physical parameters, a wide variety of flow phenomena can occur. In large arteries, the propagation of the pressure pulse depends on the elastic properties of the artery walls. In the microcirculation, the fact that blood is a suspension of cells strongly influences its flow properties and leads to a nonuniform distribution of hematocrit among microvessels. The forces acting on vessel walls include shear stress resulting from blood flow and circumferential stress resulting from blood pressure. Biological responses to these forces are important in the control of blood flow and the structural remodeling of vessels, and also play a role in major disease processes including hypertension and atherosclerosis. Consideration of hemodynamics is essential for a comprehensive understanding of the functioning of the circulatory system.
Collapse
Affiliation(s)
- Timothy W Secomb
- Department of Physiology, University of Arizona, Tucson, Arizona
| |
Collapse
|
45
|
Sarveswaran K, Kurz V, Dong Z, Tanaka T, Penny S, Timp G. Synthetic Capillaries to Control Microscopic Blood Flow. Sci Rep 2016; 6:21885. [PMID: 26905751 PMCID: PMC4764836 DOI: 10.1038/srep21885] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2015] [Accepted: 02/03/2016] [Indexed: 02/07/2023] Open
Abstract
Capillaries pervade human physiology. The mean intercapillary distance is only about 100 μm in human tissue, which indicates the extent of nutrient diffusion. In engineered tissue the lack of capillaries, along with the associated perfusion, is problematic because it leads to hypoxic stress and necrosis. However, a capillary is not easy to engineer due to its complex cytoarchitecture. Here, it is shown that it is possible to create in vitro, in about 30 min, a tubular microenvironment with an elastic modulus and porosity consistent with human tissue that functionally mimicks a bona fide capillary using "live cell lithography"(LCL) to control the type and position of cells on a composite hydrogel scaffold. Furthermore, it is established that these constructs support the forces associated with blood flow, and produce nutrient gradients similar to those measured in vivo. With LCL, capillaries can be constructed with single cell precision-no other method for tissue engineering offers such precision. Since the time required for assembly scales with the number of cells, this method is likely to be adapted first to create minimal functional units of human tissue that constitute organs, consisting of a heterogeneous population of 100-1000 cells, organized hierarchically to express a predictable function.
Collapse
Affiliation(s)
- K. Sarveswaran
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| | - V. Kurz
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| | - Z. Dong
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| | - T. Tanaka
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| | - S. Penny
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| | - G. Timp
- Depts. Biological Science and Electrical Engineering, 316 Stinson-Remick Hall, University of Notre Dame, Notre Dame, IN 46556
| |
Collapse
|
46
|
Peng SL, Wang FN, Yang TC, Hsu JC, Wu YC, Peng HH. Phase-contrast magnetic resonance imaging for the evaluation of wall shear stress in the common carotid artery of a spontaneously hypertensive rat model at 7T: Location-specific change, regional distribution along the vascular circumference, and reproducibility analysis. Magn Reson Imaging 2015; 34:624-31. [PMID: 26712655 DOI: 10.1016/j.mri.2015.12.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 12/14/2015] [Indexed: 01/18/2023]
Abstract
PURPOSE To measure wall shear stress (WSS) in the common carotid arteries (CCA) of a spontaneously hypertensive rat (SHR) model and a normotensive Wistar Kyoto rat (WKY) model by 2D phase-contrast magnetic resonance imaging (PC-MRI). MATERIALS AND METHODS PC-MRI was performed on 7 SHR and 7 WKY at ages of 4 and 7months at a 7T scanner. Images in the middle CCA (CCAmid) and in the bifurcation of CCA (CCAbifur) were acquired. The WSS values for differentiating characteristics between two models were calculated. Further, its location-specific change, regional distribution along the CCA circumference, and the reproducibility were evaluated. RESULTS In the 4-month-old rats, SHR showed lower temporal averaged WSS (WSSavg) and peak systolic WSS (WSSs) in the CCAbifur in comparison with WKY (WSSavg: 0.95±0.18 vs. 1.30±0.36N/m(2) (P<0.01); WSSs: 1.68±0.70 vs. 3.22±2.49N/m(2) (P<0.05)). We observed the same trends in the 7-month-old rats. In the SHR model, the WSSavg was lower in the CCAbifur than in the CCAmid. The regional distribution of WSSavg along the circumference of CCA showed lower values in WKY, particularly in posterior segments of CCAbifur. The intra-observer, intra-scan and inter-scan reproducibility was acceptable and the disagreements were ranged from -0.05 to 0.06N/m(2). CONCLUSION This study evaluated WSS in SHR and WKY models by 2D PC-MRI. High reproducibility analyses further indicated the reliability of measurements of WSS in the CCA of SHR and WKY models using PC-MRI at 7T.
Collapse
Affiliation(s)
- Shin-Lei Peng
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan, ROC; Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan, ROC
| | - Fu-Nien Wang
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan, ROC
| | - Tao-Chieh Yang
- Department of Neurosurgery, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan, ROC
| | - Jee-Ching Hsu
- Department of Anesthesiology, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan, Taiwan, ROC
| | - Yi-Chun Wu
- Center for Advanced Molecular Imaging and Translation, Chang Gung Memorial Hospital, Taoyuan, Taiwan, ROC
| | - Hsu-Hsia Peng
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan, ROC.
| |
Collapse
|
47
|
Lee SJ, Choi W, Seo E, Yeom E. Association of Early Atherosclerosis with Vascular Wall Shear Stress in Hypercholesterolemic Zebrafish. PLoS One 2015; 10:e0142945. [PMID: 26561854 PMCID: PMC4643039 DOI: 10.1371/journal.pone.0142945] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2015] [Accepted: 10/28/2015] [Indexed: 11/18/2022] Open
Abstract
Although atherosclerosis is a multifactorial disease, the role of hemodynamic information has become more important. Low and oscillating wall shear stress (WSS) that changes its direction is associated with the early stage of atherosclerosis. Several in vitro and in vivo models were proposed to reveal the relation between the WSS and the early atherosclerosis. However, these models possess technical limitations in mimicking real physiological conditions and monitoring the developmental course of the early atherosclerosis. In this study, a hypercholesterolaemic zebrafish model is proposed as a novel experimental model to resolve these limitations. Zebrafish larvae are optically transparent, which enables temporal observation of pathological variations under in vivo condition. WSS in blood vessels of 15 days post-fertilisation zebrafish was measured using a micro particle image velocimetry (PIV) technique, and spatial distribution of lipid deposition inside the model was quantitatively investigated after feeding high cholesterol diet for 10 days. Lipids were mainly deposited in blood vessel of low WSS. The oscillating WSS was not induced by the blood flows in zebrafish models. The present hypercholesterolaemic zebrafish would be used as a potentially useful model for in vivo study about the effects of low WSS in the early atherosclerosis.
Collapse
Affiliation(s)
- Sang Joon Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790–784, Republic of Korea
- * E-mail:
| | - Woorak Choi
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790–784, Republic of Korea
| | - Eunseok Seo
- Department of New Biology, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Dalseong, Daegu 711–873, Republic of Korea
| | - Eunseop Yeom
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), San 31, Hyoja-dong, Pohang 790–784, Republic of Korea
| |
Collapse
|
48
|
Sobczynski DJ, Fish MB, Fromen CA, Carasco-Teja M, Coleman RM, Eniola-Adefeso O. Drug carrier interaction with blood: a critical aspect for high-efficient vascular-targeted drug delivery systems. Ther Deliv 2015; 6:915-34. [PMID: 26272334 PMCID: PMC4618056 DOI: 10.4155/tde.15.38] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Vascular wall endothelial cells control several physiological processes and are implicated in many diseases, making them an attractive candidate for drug targeting. Vascular-targeted drug carriers (VTCs) offer potential for reduced side effects and improved therapeutic efficacy, however, only limited therapeutic success has been achieved to date. This is perhaps due to complex interactions of VTCs with blood components, which dictate VTC transport and adhesion to endothelial cells. This review focuses on VTC interaction with blood as well as novel 'bio-inspired' designs to mimic and exploit features of blood in VTC development. Advanced approaches for enhancing VTCs are discussed along with applications in regenerative medicine, an area of massive potential growth and expansion of VTC utility in the near future.
Collapse
Affiliation(s)
- Daniel J Sobczynski
- Department of Chemical Engineering, University of Michigan, Ann Arbor MI, USA 48109
| | - Margaret B Fish
- Department of Chemical Engineering, University of Michigan, Ann Arbor MI, USA 48109
| | - Catherine A Fromen
- Department of Chemical Engineering, University of Michigan, Ann Arbor MI, USA 48109
| | - Mariana Carasco-Teja
- Department of Chemical Engineering, University of Michigan, Ann Arbor MI, USA 48109
| | - Rhima M Coleman
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA 48109
| | - Omolola Eniola-Adefeso
- Department of Chemical Engineering, University of Michigan, Ann Arbor MI, USA 48109
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA 48109
| |
Collapse
|
49
|
Woldman YY, Eubank TD, Mock AJ, Stevens NC, Varadharaj S, Turco J, Gavrilin MA, Branchini BR, Khramtsov VV. Detection of nitric oxide production in cell cultures by luciferin-luciferase chemiluminescence. Biochem Biophys Res Commun 2015; 465:232-8. [PMID: 26253471 DOI: 10.1016/j.bbrc.2015.08.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2015] [Accepted: 08/01/2015] [Indexed: 11/24/2022]
Abstract
A chemiluminescent method is proposed for quantitation of NO generation in cell cultures. The method is based on activation of soluble guanylyl cyclase by NO. The product of the guanylyl cyclase reaction, pyrophosphate, is converted to ATP by ATP sulfurylase and ATP is detected in a luciferin-luciferase system. The method has been applied to the measurement of NO generated by activated murine macrophages (RAW 264.7) and bovine aortic endothelial cells. For macrophages activated by lipopolysaccharide and γ-interferon, the rate of NO production is about 100 amol/(cell·min). The rate was confirmed by the measurements of nitrite, the product of NO oxidation. For endothelial cells, the basal rate of NO generation is 5 amol/(cell·min); the rate approximately doubles upon activation by bradykinin, Ca(2+) ionophore A23187 or mechanical stress. For both types of cells the measured rate of NO generation is strongly affected by inhibitors of NO synthase. The sensitivity of the method is about 50 pM/min, allowing the registration of NO generated by 10(2)-10(4) cells. The enzyme-linked chemiluminescent method is two orders of magnitude more sensitive than fluorescent detection using 4-amino-5-methylamino-2',7'-difluorofluorescein (DAF-FM).
Collapse
Affiliation(s)
- Yakov Y Woldman
- Department of Chemistry, Valdosta State University, Valdosta, GA 31698, USA.
| | - Tim D Eubank
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, OH 43210, USA
| | - Andrew J Mock
- Department of Biology, Valdosta State University, Valdosta, GA 31698, USA
| | - Natalia C Stevens
- Department of Biology, Valdosta State University, Valdosta, GA 31698, USA
| | - Saradhadevi Varadharaj
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, OH 43210, USA
| | - Jenifer Turco
- Department of Biology, Valdosta State University, Valdosta, GA 31698, USA
| | - Mikhail A Gavrilin
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, OH 43210, USA
| | - Bruce R Branchini
- Department of Chemistry, Connecticut College, New London, CT 06320, USA
| | - Valery V Khramtsov
- Davis Heart & Lung Research Institute, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
50
|
Effect of variation in hemorheology between human and animal blood on the binding efficacy of vascular-targeted carriers. Sci Rep 2015; 5:11631. [PMID: 26113000 PMCID: PMC4481524 DOI: 10.1038/srep11631] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Accepted: 06/01/2015] [Indexed: 11/10/2022] Open
Abstract
Animal models are extensively used to evaluate the in vivo functionality of novel drug delivery systems (DDS). However, many variations likely exist in vivo between the animals and human physiological environment that significantly alter results obtained with animal models relative to human system. To date, it is not clear if the variation in hemorheology and hemodynamics between common animal and human models affect the functionality of DDS. This study investigates the role of hemorheology of humans and various animal models in dictating the binding efficiency of model vascular-targeted carriers (VTCs) to the wall in physiological blood flows. Specifically, the adhesion of sLeA-coated nano- and micro-spheres to inflamed endothelial cells monolayers were conducted via a parallel plate flow chamber assay with steady and disturbed red blood cells (RBCs)-in-buffer and whole blood flows of common animal models. Our results suggest that the ratio of carrier size to RBC size dictate particle binding in blood flow. Additionally, the presence of white blood cells affects the trend of particle adhesion depending on the animal species. Overall, this work sheds light on some deviation in VTC vascular wall interaction results obtained with in vivo animal experimentation from expected outcome and efficiency in vivo in human.
Collapse
|