1
|
Qiu SX, Fadel D, Hui A. Scleral Lenses for Managing Dry Eye Disease in the Absence of Corneal Irregularities: What Is the Current Evidence? J Clin Med 2024; 13:3838. [PMID: 38999403 PMCID: PMC11242693 DOI: 10.3390/jcm13133838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/15/2024] [Accepted: 06/26/2024] [Indexed: 07/14/2024] Open
Abstract
Scleral lenses (SLs) are large-diameter rigid contact lenses that are a mainstay treatment for eyes with corneal irregularities. In recent years, there has been increased interest in the role of managing dry eye disease (DED) with SLs, as many patients with DED have reported symptomatic relief with SL wear. The role of SLs for DED management when there are associated corneal irregularities is supported by individual case reports and studies. This has prompted practitioners to begin advocating using SLs in DED cases, even in the absence of associated corneal irregularities and other ocular surface diseases (OSDs). There have also been discussions on potentially placing SLs earlier in the treatment hierarchy of DED, where it currently sits at a more advanced level of intervention (Step 3) in the TFOS DEWS II Report. This review will present the currently available, albeit sparse, evidence that supports and suggests this practice, as well as ancillary evidence supporting the purported benefits of SL wear in DED. The advantages of SL wear, such as corneal healing, absence of tear evaporation and contact lens dehydration, and improved visual acuity with associated increased wear comfort, and how this will benefit DED patients will be explored. Conversely, the challenges associated with fitting SLs in DED patients, including increased midday fogging, poor wettability, and subjective patient satisfaction, will also be presented, as well as a discussion on the key considerations for SL fitting in this population. Overall, while more research is needed to support the use of SLs in DED patients without associated corneal irregularities and other forms of OSD, the use of these lenses may prove to have a potentially wider role given their reported ancillary benefits in these populations.
Collapse
Affiliation(s)
- Sharon X Qiu
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Daddi Fadel
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Alex Hui
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW 2052, Australia
| |
Collapse
|
2
|
Blanco-Vázquez M, Gil-Cazorla R, Barua A, Taneja M, Hanneken L, Shah S. Impact of thermo-mechanical skin treatment on refraction and keratometry in patients with dry eye disease and the implications for cataract surgery. Cont Lens Anterior Eye 2024; 47:102164. [PMID: 38594154 DOI: 10.1016/j.clae.2024.102164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Revised: 01/11/2024] [Accepted: 03/30/2024] [Indexed: 04/11/2024]
Abstract
PURPOSE To determine the changes in keratometry measurements and refraction in patients having the thermo-mechanical periorbital skin treatment, Tixel®, to treat dry eye disease (DED). METHODS A multi-centre, prospective, non-masked study was conducted. DED patients were recruited in 3 international centres and were evaluated in 5 visits separated by an interval of 2 weeks except for the last visit which took place after 18 weeks from visit 1. The same clinical examination was performed at all visits: OSDI questionnaire, tear stability, keratometry, best corrected visual acuity and refraction. Tixel® treatment was applied at the first 3 visits. RESULTS 89 participants (24 males/65 females; mean age: 55.0 ± 14.2 years) were included: 20 presented moderate DED symptoms and 69 severe DED symptoms. Significant differences were found for the spherocylindrical refraction (vector analysis) between visit 1 and visits 2 and 3. Following cumulative analysis, 11.86 % and 16.94 % of participants had more than 0.5 dioptre (D) change in mean keratometry and keratometric astigmatism, respectively, at 3 months post-treatment. A total of 5.40 % had a sphere and cylinder change greater than 0.50D and 16.21 % had the axis changed more than 10 degrees (vector analysis). These changes were particularly significant in patients with severe DED symptoms. CONCLUSIONS Keratometry readings and refraction can change following thermo-mechanical skin treatment for DED, especially in those patients with severe DED symptoms. This should be considered as potential errors in intraocular lens calculations may be induced.
Collapse
Affiliation(s)
- Marta Blanco-Vázquez
- Ocular Surface Group, Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain
| | - Raquel Gil-Cazorla
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, United Kingdom.
| | - Ankur Barua
- Midland Eye, Solihull, United Kingdom; Birmingham and Midland Eye Centre, City Hospital, Birmingham, United Kingdom
| | | | | | - Sunil Shah
- College of Health & Life Sciences, Aston University, Birmingham, United Kingdom; Midland Eye, Solihull, United Kingdom; Birmingham and Midland Eye Centre, City Hospital, Birmingham, United Kingdom; Khmer Sight Foundation, Phnom Penh, Cambodia
| |
Collapse
|
3
|
Teshigawara T, Akaishi M, Mizuki Y, Takeuchi M, Hata S, Meguro A, Mizuki N. Effect of Long-Acting Diquafosol Sodium on Astigmatism Measurement Repeatability in Preoperative Cataract Cases with Dry Eyes: A Multicenter Prospective Study. Ophthalmol Ther 2024; 13:1743-1755. [PMID: 38662192 PMCID: PMC11109081 DOI: 10.1007/s40123-024-00940-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 03/22/2024] [Indexed: 04/26/2024] Open
Abstract
INTRODUCTION Dry eye can compromise corneal astigmatism measurement repeatability during preoperative cataract surgery examination. No previous studies have analyzed the effectiveness of long-acting 3% diquafosol sodium (LA-DQS) on astigmatism measurement repeatability. This research assessed the effect of LA-DQS on astigmatism measurement repeatability in preoperative patients with cataract and short tear break-up time (TBUT) type dry eyes in both eyes of the same patient. Correlations between repeatability and TBUT, corneal high-order aberrations (HOAs), and corneal astigmatism magnitude were also analyzed. METHODS In total, 122 eyes (61 patients) with short TBUT-type dry eye were enrolled. Preoperatively, only one eye of all patients was treated with LA-DQS for 4 weeks. TBUT and corneal HOAs were checked using CASIA 2 before and 4 weeks post-treatment. The cylindrical power and meridian of astigmatism were measured at 3- and 4-week post-treatment using IOLMaster 700. Power vectors J0 and J45 were used for astigmatism calculations. Repeatability of astigmatism measurements was assessed as the within-subject standard deviation (Sw). The relative effects of TBUT and HOAs on J0 Sw and J45 Sw were also analyzed. Comparative changes in these variables were evaluated between treated and non-treated eyes, with additional analysis of their correlations. RESULTS Treated eyes exhibited significant improvements in TBUT, HOAs, and post-treatment measurements of J0 Sw and J45 Sw at 3 and 4 weeks. In non-treated eyes, J0 Sw and J45 Sw showed significant correlation with TBUT and corneal HOAs. HOAs showed stronger relative associations with J0 Sw and J45 Sw than TBUT. In non-treated eyes, no significant correlation was found between cylindrical power and astigmatism measurement repeatability. CONCLUSIONS In short TBUT-type dry eye, preoperative treatment with LA-DQS significantly improved astigmatism measurement repeatability. This may improve the precision of intraocular lens (IOL) power calculations regardless of the magnitude of corneal astigmatism, especially when toric IOLs are used.
Collapse
Affiliation(s)
- Takeshi Teshigawara
- Department of Ophthalmology, Yokosuka Chuoh Eye Clinic, 2-6 Odaki-cho, Yokosuka, Kanagawa, 238-0008, Japan.
- Department of Ophthalmology, Tsurumi Chuoh Eye Clinic, Tsurumi, Yokohama, Kanagawa, Japan.
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan.
| | - Miki Akaishi
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan
| | - Yuki Mizuki
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan
| | - Masaki Takeuchi
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan
| | - Seiichiro Hata
- Department of Ophthalmology, Yokohama Sky Eye Clinic, Yokohama, Kanagawa, Japan
| | - Akira Meguro
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan
| | - Nobuhisa Mizuki
- Department of Ophthalmology, Yokohama City University School of Medicine, Kanazawa, Yokohama, Kanagawa, Japan
| |
Collapse
|
4
|
Abbott K, Hanson KS, Lally J. Prevalence of dry eye disease in the low vision population at the University of Colorado. JOURNAL OF OPTOMETRY 2024; 17:100501. [PMID: 37944476 PMCID: PMC10652114 DOI: 10.1016/j.optom.2023.100501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Revised: 09/22/2023] [Accepted: 10/11/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE To evaluate the prevalence of diagnosed dry eye syndrome, meibomian gland dysfunction, and blepharitis amongst the low vision population. METHODS A retrospective analysis was conducted on patients seen in the University of Colorado Low Vision Rehabilitation Service between the dates of 12/1/2017 and 12/1/2022. 74 ICD-10 codes were used to identify patients as having dry eye syndrome or not having dry eye syndrome. Data was further analyzed to determine the prevalence of blepharitis and meibomian gland dysfunction using 29 blepharitis and 9 meibomian gland dysfunction ICD-10 codes. Data were also analyzed to determine the age and sex of the patients with diagnosed dry eye syndrome. RESULTS The percentage of patients with a diagnosis of dry eye syndrome by an eyecare provider was 38.02 %. The prevalence of dry eye syndrome by age group was 3.57 % for 0-19 years, 14.35 % for 20-39 years, 29.07 % for 40-59 years, 43.79 % for 60-79 years, and 46.21 % for 80 and above. The prevalence of meibomian gland dysfunction and blepharitis was 11.90 % and 9.1 % respectively. Dry eye syndrome prevalence amongst males was 31.59 % and 42.47 % for females. CONCLUSION This study demonstrates that dry eye syndrome in the low vision population is a significant co-morbidity occurring in over a third of patients in the University of Colorado Low Vision Rehabilitation Service. These findings are meaningful as ocular comfort should not be overlooked while managing complex visual needs.
Collapse
Affiliation(s)
- Kaleb Abbott
- University of Colorado School of Medicine Anschutz Medical Campus Department of Ophthalmology 1675 Aurora Court Aurora, CO 80045, USA.
| | - Kara S Hanson
- University of Colorado School of Medicine Anschutz Medical Campus Department of Ophthalmology 1675 Aurora Court Aurora, CO 80045, USA
| | - James Lally
- University of Colorado School of Medicine Anschutz Medical Campus Department of Ophthalmology 1675 Aurora Court Aurora, CO 80045, USA
| |
Collapse
|
5
|
Yang CJ, Anand A, Huang CC, Lai JY. Unveiling the Power of Gabapentin-Loaded Nanoceria with Multiple Therapeutic Capabilities for the Treatment of Dry Eye Disease. ACS NANO 2023; 17:25118-25135. [PMID: 38051575 DOI: 10.1021/acsnano.3c07817] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Dry eye (DE) disease, which is primarily linked to aqueous deficiency, is an escalating health issue worldwide, mainly due to the widespread use of electronic devices. The major obstacles in DE pharmacotherapy include insufficient therapeutic efficacy and low ocular bioavailability. This study presents the development of a ceria-based nanosystem to carry gabapentin (GBT), aiming to offer comprehensive relief from DE symptoms. We prepared multifunctional nanoceria capped with thiolated gelatin followed by cross-linking with glutaraldehyde, yielding a nanocarrier with desirable biocompatibility and antioxidant, anti-inflammatory, antiangiogenic, antiapoptotic, and neuronal protective activities. Specifically, the highly abundant thiol groups on gelatin increased the cellular uptake of the nanocarrier by 2.3-fold and its mucin-binding efficiency by 10-fold, thereby extending ocular retention and amplifying therapeutic activity. Moderate cross-linking of the thiolated gelatin not only enhanced the ocular bioavailability of the nanoceria but also provided slow, degradation-controlled release of GBT to promote the lacrimal stimulation to restore the tear film. In a rabbit model of DE, topical administration of our GBT/nanoceria nanoformulation resulted in comprehensive alleviation of symptoms, including repairing corneal epithelial damage, preserving corneal nerve density, and stimulating tear secretion, demonstrating superior performance in comparison to the free drug. These results underscore the safety and potential of this innovative nanoformulation for DE pharmacotherapy.
Collapse
Affiliation(s)
- Chia-Jung Yang
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Anisha Anand
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| | - Chih-Ching Huang
- Department of Bioscience and Biotechnology, National Taiwan Ocean University, Keelung 202301, Taiwan
- Center of Excellence for the Oceans, National Taiwan Ocean University, Keelung 202301, Taiwan
- School of Pharmacy, College of Pharmacy, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
| | - Jui-Yang Lai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taoyuan 33305, Taiwan
- Department of Materials Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan
- Research Center for Chinese Herbal Medicine, College of Human Ecology, Chang Gung University of Science and Technology, Taoyuan 33303, Taiwan
- Center for Biomedical Engineering, Chang Gung University, Taoyuan 33302, Taiwan
| |
Collapse
|
6
|
Huang T, Wang Y, Zhu Z, Wu Q, Chen D, Li Y. Moisture chamber goggles for the treatment of postoperative dry eye in patients receiving SMILE and FS-LASIK surgery. BMC Ophthalmol 2023; 23:501. [PMID: 38066467 PMCID: PMC10709852 DOI: 10.1186/s12886-023-03241-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Accepted: 11/23/2023] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND The incidence of refractive surgery-related dry eye disease (DED) is rising due to the increasing popularity of corneal refractive surgery. The moisture chamber goggles (MCGs) have been shown to tear evaporation by increasing local humidity and minimizing airflow. The current study aims to evaluate the efficacy of moisture chamber goggles for refractive surgery-related DED. METHODS In this nonrandomized open-label controlled study, 78 participants (156 eyes) receiving refractive surgery were enrolled between July 2021 and April 2022, and sequentially allocated to MGC and control groups. 39 participants were allocated to the MGC groups, of which 53.8% received small-incision lenticule extraction (SMILE) and 46.2% received femtosecond laser-assisted in situ keratomileusis (FS-LASIK), and were instructed to wear MCGs for the duration of 1 month postoperatively, in addition to the standard postoperative treatment received by the control groups (56.4% SMILE, 43.6% FS-LASIK). Participants underwent full ophthalmic examinations, including visual acuity, manifest refraction, DED evaluations, and higher-order aberrations (HOAs), both preoperatively and at routine follow-ups 1 day, 1 week, and 1 month after surgery. DED parameters included non-invasive tear film break-up time (NIBUT), tear meniscus height (TMH), conjunctival congestion, lipid layer thickness (LLT), and ocular surface disease index (OSDI) questionnaires. Student's t-test was used for comparisons between control and MCG groups, and between preoperative and postoperative parameters within groups. RESULTS Postoperative NIBUT decreased in both SMILE and FS-LASIK control groups 1 day after the surgery (SMILE, P = 0.001; FS-LASIK, P = 0.008), but not in the corresponding MCG groups (SMILE, P = 0.097; FS-LASIK, P = 0.331). TMH in the MCG group was significantly higher at 1 week (P = 0.039) and 1 month (P = 0.015) in SMILE, and 1 day (P = 0.003) in FS-LASIK groups. In FS-LASIK participants, significantly lower HOAs and coma levels in the MCG group were observed 1 day (total HOAs, P = 0.023; coma, P = 0.004) and 1 week (total HOAs, P = 0.010, coma, P = 0.004) after surgery. No consistent statistically significant intergroup difference was observed between MCG and control groups in conjunctival congestion, LLT, and OSDI. CONCLUSIONS MCGs effectively slowed tear evaporation, increased tear film stability, and improved HOAs in patients receiving SMILE and FS-LASIK surgeries. MCG is an effective adjuvant therapy in the comprehensive management of refractive surgery-related DED.
Collapse
Affiliation(s)
- Tianze Huang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Yuchen Wang
- Department of Ophthalmology, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310003, Zhejiang, China
| | - Zhou Zhu
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Qingyang Wu
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Di Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan 1, Beijing, 100005, Dongcheng District, China.
| |
Collapse
|
7
|
Saad A, Frings A. Influence of perfluorohexyloctane (Evotears®) on higher order aberrations. Int Ophthalmol 2023; 43:5025-5030. [PMID: 37864619 PMCID: PMC10724091 DOI: 10.1007/s10792-023-02905-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 09/27/2023] [Indexed: 10/23/2023]
Abstract
PURPOSE To prospectively assess the effect of regular application of perfluorohexyloctane (F6H8; Evotears®) on the tear film lipid layer, higher order aberrations (HOA) and the repeatability of measurements in healthy eyes. METHODS This prospective clinical study included 104 eyes treated with F6H8 four times daily for four weeks (group A) and 101 eyes that served as controls (group B). Measurements were performed with the WASCA aberrometer (Carl Zeiss Meditec GmbH, Jena, Germany). Main outcome measurement in addition to subjective refraction were the root mean square values of HOA measured before and after the intervention. RESULTS Regular use of F6H8 over a period of four weeks significantly increases HOA in healthy eyes (p < 0.05). In addition, the repeatability of measurement increases after the application of F6H8. CONCLUSION F6H8 may be a suitable treatment option to improve the accuracy of refractive assessment, although it increases HOA. Further studies are needed to confirm the effect on HOA and the repeatability of measurement.
Collapse
Affiliation(s)
- Amr Saad
- Department of Ophthalmology, University Hospital Duesseldorf, Heinrich-Heine University, Moorenstraße 5, 40225, Duesseldorf, Germany.
| | - Andreas Frings
- Department of Ophthalmology, University Hospital Duesseldorf, Heinrich-Heine University, Moorenstraße 5, 40225, Duesseldorf, Germany
- Augenheilkunde und Augenlaserzentrum PD Dr. med. Frings Nuremberg, Jena, Germany
| |
Collapse
|
8
|
Gao D, Lv X, Zhang F, Song Y, Xu Y. Effect of 3% Diquafosol Sodium on Dry Eye After Femtosecond Laser-Assisted In Situ Keratomileusis and Small Incision Lenticule Extraction Surgery in High-Myopic Eyes. Eye Contact Lens 2023; 49:489-497. [PMID: 37729174 DOI: 10.1097/icl.0000000000001040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/06/2023] [Indexed: 09/22/2023]
Abstract
PURPOSE To evaluate the effect of 3% diquafosol sodium eye drop on dry eye after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE) in high-myopic eyes. METHODS Eighty-one cases with high myopia (162 eyes) who received FS-LASIK or SMILE were divided into four groups by surgical design and tear film stability: D-FS-LASIK (5s RESULTS The D-SMILE group showed increase in BUT postoperatively (1m: P =0.006, 3m: P =0.004), whereas C-FS-LASIK (1m: P =0.012) and C-SMILE (1m: P =0.036) groups showed decrease in BUT. Higher ΔBUT were observed in D-FS-LASIK (1m: P =0.027) and D-SMILE (1m: P =0.001, 3m: P =0.012) postoperatively. The D-FS-LASIK group showed less decrease than C-FS-LASIK group in Schirmer I. The D-SMILE group showed increase in Schirmer I, whereas C-SMILE showed decrease in 3 months. ΔOSDI was lower in D-SMILE group than in C-SMILE group (1m: P =0.026, 3m: P =0.035). Fatigue was severer in D-SMILE group than in C-SMILE group preoperatively ( P =0.019), although there was no significant difference postoperatively. Objective scattering index (1m: P =0.002, 3m: P =0.021) and tear film objective scattering index (1m: P =0.005, 3m: P =0.010) were lower in D-FS-LASIK group than in C-FS-LASIK group postoperatively. The D-FS-LASIK group showed better VA20% ( P =0.036) and VA9% ( P =0.027) than the C-FS-LASIK group 1 month postoperatively. CONCLUSIONS 3% Diquafosol sodium eye drop was effective for SMILE and FS-LASIK-related dry eye in high-myopic eyes. It is necessary to focus on perioperative anti-dry eye management and especially pay attention to the eyes with risk factors, including unstable tear film, high myopia, and FS-LASIK surgery.
Collapse
Affiliation(s)
- Dengxin Gao
- Beijing Ophthalmology and Visual Science Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | | | | | | | | |
Collapse
|
9
|
Ayaki M, Kuze M, Negishi K. Association of eye strain with dry eye and retinal thickness. PLoS One 2023; 18:e0293320. [PMID: 37862343 PMCID: PMC10588844 DOI: 10.1371/journal.pone.0293320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Accepted: 10/09/2023] [Indexed: 10/22/2023] Open
Abstract
PURPOSE The purpose of this cohort study was to investigate the association between the prevalence of abnormal ocular examination results and the common visual symptoms of eye strain, blurred vision and photophobia. METHODS Consecutive first-visit outpatients with best-corrected visual acuity better than 20/30 in both eyes were enrolled and those with a history of intra-ocular lens implantation and glaucoma were excluded. Dry eye-related examinations and retinal thickness measurement were conducted. The odds ratio (OR) was calculated with logistic regression analyses of ocular data in relation to the presence of visual symptoms. RESULTS A total of 6078 patients (3920 women, mean age 49.0 ± 20.4 years) were analyzed. The prevalence of each symptom was 31.8% for eye strain, 22.5% for blurred vision and 16.0% for photophobia. A significant risk factor for eye strain was short tear break-up time (TBUT) (OR 1.88), superficial punctate keratitis (SPK) (OR 1.44), and thickness of ganglion cell complex (GCC) (OR 1.30). Risk factors for blurred vision were short TBUT (OR 1.85), SPK (OR 1.24) and GCC (OR 0.59). Risk factors for photophobia were short TBUT (OR 1.77) and SPK (OR 1.32). Schirmer test value, peripapillary nerve fiber layer thickness and full macular thickness were not associated with the tested symptoms. CONCLUSION The current study successfully identified female gender, short TBUT, and SPK as significant risk factors for eye strain, blurred vision, and photophobia with considerable ORs.
Collapse
Affiliation(s)
- Masahiko Ayaki
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- Otake Eye Clinic, Kanagawa, Japan
| | | | - Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|
10
|
Martin R. Symptoms of dry eye related to the relative humidity of living places. Cont Lens Anterior Eye 2023; 46:101865. [PMID: 37208284 DOI: 10.1016/j.clae.2023.101865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 05/09/2023] [Accepted: 05/11/2023] [Indexed: 05/21/2023]
Abstract
PURPOSE To investigate the impact of relative humidity (RH) and climate variables of the place of residence on symptoms of dry eye disease (DED) in primary eye care practice. METHODS A cross-sectional analysis of the Ocular Surface Disease Index (OSDI) dry eye classification of 1.033 patients [classified as non-DED (OSDI ≤22) and DED (OSDI >22)] was conducted in a multicentre study in Spain. Participants were classified according to the 5-year RH value (data from the Spanish Climate Agency -www.aemet.es) into two groups: those who lived in low RH (<70%) places and those who lived in high RH (≥70%) places. Additionally, differences in daily climate records (EU Copernicus Climate Change Service) were assessed. RESULTS The prevalence of DED symptoms was 15.5% (95% CI 13.2%-17.6%). Participants who lived in places with <70% RH showed a higher prevalence of DED (17.7%; 95% CI 14.5%-21.1%; P < 0.01 adjusted for age and sex) than those who lived in places with ≥70% RH (13.6%; 95% CI 11.1%-16.7%) and a closer, but not statistically significant, risk for DED (OR = 1.34, 95% CI 0.96 to 1.89; P = 0.09) than previously described DED risk factors [age older than 50 years (OR = 1.51, 95% CI 1.06 to 2.16; P = 0.02) and female sex (OR = 1.99, 95% CI 1.36 to 2.90; P < 0.01)]. Some climate data showed statistically significant differences (P < 0.05) between participants with DED and non-DED (mean wind gusts; atmospheric pressure; mean and minimum relative humidity); these variables did not significantly increase DED risk (OR close to 1.0 and P > 0.05). CONCLUSION This study is the first to describe the impact of climate data on dryness symptomatology in Spain, confirming that participants who live in locations with RH <70% have a higher prevalence (corrected for age and sex) of DED. These findings support the use of climate databases in DED research.
Collapse
Affiliation(s)
- R Martin
- Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA), Paseo de Belén, 17 - Campus Miguel Delibes, Valladolid 47011, España; Universidad de Valladolid, Departamento de Física Teórica, Atómica y Óptica, Paseo de Belén, 7 - Campus Miguel Delibes, Valladolid 47011, España; Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid, Spain.
| |
Collapse
|
11
|
Ren X, Wang Y, Wu T, Jing D, Li X. Binocular dynamic visual acuity in dry eye disease patients. Front Neurosci 2023; 17:1108549. [PMID: 36968505 PMCID: PMC10030492 DOI: 10.3389/fnins.2023.1108549] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Accepted: 02/17/2023] [Indexed: 03/10/2023] Open
Abstract
PurposeTo investigate binocular dynamic visual acuity (DVA) for patients with dry eye disease (DED).MethodsThe prospective study included DED patients. The binocular DVA at 40 and 80 degrees per second (dps), Ocular Surface Disease Index (OSDI), tear meniscus height (TMH), tear film break-up time first (TBUTF), corneal fluorescein staining (CFS), eyelid margin abnormalities and meibomian gland (MG) abnormalities morphology and function were evaluated. A deep learning model was applied to quantify the MG area proportion. The correlation between DVA and DED parameters was analyzed.ResultsA total of 73 DED patients were enrolled. The age, OSDI, CFS, MG expressibility, secretion quality, and eyelid margin abnormalities were significantly positively correlated with the DVA for 40 and 80 dps (all P < 0.05). The MG area proportion in the upper eyelid was negatively correlated with DVA at 40 dps (R = −0.293, P < 0.001) and at 80 dps (R = −0.304, P < 0.001). Subgroup analysis by MG grade demonstrated that the DVA of patients with severe MG dropout (<25% of the total area) was significantly worse than other mild and moderate groups, both in 40 and 80 dps (all P < 0.05). The patients with CFS showed worse 40 (P < 0.001) and 80 dps (P < 0.001) DVA than the patients without CFS.ConclusionBinocular DVA is significantly associated with DED symptoms and signs. The DED patients with CFS and severe MG dropout and dysfunction have worse DVA.
Collapse
|
12
|
Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction. Ophthalmol Ther 2023; 12:1595-1610. [PMID: 36862309 PMCID: PMC10164219 DOI: 10.1007/s40123-023-00693-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 02/14/2023] [Indexed: 03/03/2023] Open
Abstract
INTRODUCTION The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device). METHODS A total of 56 eyes (56 patients) were included in this prospective study. Corneal aberrations were analyzed for the anterior, posterior, and total cornea surfaces. Within-subject standard deviation (Sw), test-retest repeatability (TRT), and intraclass correlation coefficient (ICC) were used to assess the intraobserver repeatability and interobserver reproducibility. The differences were evaluated by paired t-test. Bland-Altman plots and 95% limits of agreement (95% LoA) were used to evaluate the agreement. RESULTS High repeatability was observed for anterior and total corneal parameters, with Sw value < 0.07, TRT ≤ 0.16, and ICCs > 0.893, but not trefoil. For the posterior corneal parameters, ICCs varied from 0.088 to 0.966. Regarding interobserver reproducibility, all Sw values were ≤ 0.04 and TRT ≤ 0.11. ICCs ranged from 0.846 to 0.989, from 0.432 to 0.972, and from 0.798 to 0.985 for the anterior, total, and posterior corneal aberrations parameters, respectively. The mean difference in all aberrations was ≤ 0.05 μm. All parameters showed a narrow 95% LoA. CONCLUSION The MS-39 device achieved high precision in both anterior and total corneal measurements; the precision of posterior corneal higher-order RMS, astigmatism II, coma, and trefoil was lower. The two technologies used by the MS-39 and Sirius devices can be used interchangeably for measuring corneal HOAs after SMILE.
Collapse
|
13
|
Yagi H, Shimizu E, Yagi R, Uchino M, Kamoi M, Asai K, Tsubota K, Negishi K, Ogawa Y. Pediatric chronic graft-versus-host disease-related dry eye disease and the diagnostic association of potential clinical findings. Sci Rep 2023; 13:3575. [PMID: 36864106 PMCID: PMC9981701 DOI: 10.1038/s41598-023-30288-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 02/21/2023] [Indexed: 03/04/2023] Open
Abstract
Pediatric graft-versus-host-disease (GVHD)-related dry eye disease (DED) is often overlooked due to a lack of subjective symptoms and reliable testing, leading to irreversible corneal damage. To study the clinical findings contributing to the accurate detection of pediatric GVHD-related DED, a retrospective study of pediatric patients treated with hematopoietic stem cell transplantation (HSCT) at Keio University Hospital between 2004 and 2017 was conducted. Association and diagnostic values of ophthalmological findings for DED were analyzed. Twenty-six patients who had no ocular complications before HSCT were included in the study. Eleven (42.3%) patients developed new-onset DED. The cotton thread test showed excellent diagnostic accuracy in detecting DED (area under the receiver operating curve, 0.96; sensitivity, 0.95; specificity, 0.85) with a cut-off of 17 mm, which was higher than the conventional threshold of 10 mm. Additionally, the presence of filamentary keratitis (FK) and pseudomembranous conjunctivitis (PC) were significantly associated with the diagnosis of DED (p value, 0.003 and 0.001 for FK and PC, respectively) and displayed good diagnostic performance (sensitivity, 0.46 and 0.54; specificity, 0.97 and 0.97 for FK and PC, respectively). In conclusion, the cotton thread test with a new threshold, the presence of PC and FK, could be helpful for promptly detecting pediatric GVHD-related DED.
Collapse
Affiliation(s)
- Hitomi Yagi
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Eisuke Shimizu
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Ryuichiro Yagi
- Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, MA, USA
| | - Miki Uchino
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Mizuka Kamoi
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Kazuki Asai
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
- Tsubota Laboratory, Inc, Tokyo, Japan
| | - Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan
| | - Yoko Ogawa
- Department of Ophthalmology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan.
| |
Collapse
|
14
|
Joshi VP, Chatterjee S, Basu S. Relationship of Density, Depth, and Surface Irregularity of Superficial Corneal Opacification with Visual Acuity. Curr Eye Res 2023; 48:536-545. [PMID: 36724802 DOI: 10.1080/02713683.2023.2173786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To explore the relationship between the density, depth, and surface irregularity of superficial corneal opacities and vision. METHODS This prospective imaging study included 19 patients with unilateral superficial corneal opacification due to scarring post-microbial keratitis. Each eye underwent an assessment of uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), contact lens corrected visual acuity (CLCVA), and Scheimpflug and anterior segment optical tomography imaging. Regression analysis was performed to detect the association between density, depth of scarring, and the surface irregularity in terms of higher order aberrations (HOA), and keratometry and UCVA, CLCVA, and the difference between BSCVA and CLCVA. RESULTS The mean logMAR UCVA, BSCVA, and CLCVA were 0.76, 0.35, and 0.28, respectively. The corneal scars had a mean thickness of 158.7 ± 61 µ and density of 65.73 ± 24.46 GSU. Bivariate analysis model for UCVA showed an association with Z42 secondary astigmatism (p = 0.02), Z44 quadrafoil (p = 0.01), combined coma Z3 ± 1(p = 0.03), and combined HOA Z3-Z6 (p = 0.045), out of which Z44 Quadrafoil (p = 0.04) was most significant with multivariate analysis. Bivariate analysis for BCVA-CLVA showed association with Z31 coma horizontal (p = 0.04), Z33 oblique trefoil (p = 0.02), Z40 primary spherical aberration (p = 0.008), and Z5 - 5 (p = 0.007), out of which Z31 horizontal coma (p = 0.04) and Z40 spherical aberration (p = 0.009) were significant on multivariate analysis. Change in densitometry, corneal thickness, epithelial:stromal reflectivity ratio, scar depth, and keratometry did not show any significant association with UCVA, BSCVA-CLCVA, or CLCVA. CONCLUSION In superficial corneal stromal scarring, deranged surface irregularity parameters like higher-order aberrations affect the final visual acuity more than the depth or density of the opacity.
Collapse
Affiliation(s)
- Vineet Pramod Joshi
- Shantilal Shanghvi Cornea Institute, LV Prasad Eye Institute, Hyderabad, India.,Professor Brien Holden Eye Research Centre, LV Prasad Eye Institute, Hyderabad, India
| | - Subhajit Chatterjee
- Cataract, Refractive Surgery and Contact Lens Services, LV Prasad Eye Institute, Hyderabad, India
| | - Sayan Basu
- Shantilal Shanghvi Cornea Institute, LV Prasad Eye Institute, Hyderabad, India.,Professor Brien Holden Eye Research Centre, LV Prasad Eye Institute, Hyderabad, India
| |
Collapse
|
15
|
Nibandhe AS, Donthineni PR. Understanding and Optimizing Ocular Biometry for Cataract Surgery in Dry Eye Disease: A Review. Semin Ophthalmol 2023; 38:24-30. [PMID: 35989638 DOI: 10.1080/08820538.2022.2112699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
PURPOSE To understand the impact of dry eye disease (DED) on the components of ocular biometry and ways to optimize the visual outcomes of cataract surgery in eyes with DED. METHODOLOGY A thorough literature review of the components pertaining to this review was undertaken using the databases, PubMed (from the year 2000), MEDLINE, CENTRAL (including Cochrane Eyes and Vision Trials Register; Cochrane Library: Issue 12 of 12 December 2019), metaRegister of Controlled Trials (mRCT) (www.controlled-trials. com), ClinicalTrials.gov (www.clinicaltrial.gov) and WHO International Clinical Trials Registry Platform (www.who.int/ictrp/search/en). The keywords used for the search included "cataract surgery" or "phacoemulsification" combined with "dry eye", "dry eye disease","biometry", "keratometry". RESULTS Publications considered for this review included meta-analysis, systematic reviews, case-control and cohort studies, case series, and laboratory-based studies. Published articles reporting tear film alteration in DED, its impact on the quality of vision and optical aberrations, the effect of topical medications on keratometry variations, and reports on optimizing the ocular surface before cataract surgery were included. CONCLUSIONS DED is a common entity seen in patients presenting to routine cataract clinics and is known to impact the accuracy, reliability, and repeatability of ocular biometry and IOL power calculations in them. This review intends to emphasize the preoperative screening for the presence of DED, initiation of appropriate medical management for optimization of the ocular surface before cataract surgery, and recommendations for performing biometry. The algorithmic approach proposed will help the general ophthalmologists in routine practice to provide quality care and acceptable visual outcomes in patients with pre-existing DED.
Collapse
|
16
|
Jing D, Jiang X, Ren X, Su J, Wei S, Hao R, Chou Y, Li X. Change Patterns in Corneal Intrinsic Aberrations and Nerve Density after Cataract Surgery in Patients with Dry Eye Disease. J Clin Med 2022; 11:jcm11195697. [PMID: 36233565 PMCID: PMC9572385 DOI: 10.3390/jcm11195697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/12/2022] [Accepted: 09/22/2022] [Indexed: 11/16/2022] Open
Abstract
This study aimed to evaluate the change patterns in corneal intrinsic aberrations and nerve density after cataract surgery in dry eye disease. The preoperative, 1- and 3-month postoperative dry eye-related parameters were obtained by the Oculus keratograph and the ocular surface disease index questionnaire. The corneal intrinsic aberrations were measured using the Pentacam HR system. In vivo confocal microscopy was performed to observe the vortical and peripheral corneal nerves. An artificial intelligence technique run by the deep learning model generated the corneal nerve parameters. Corneal aberrations on the anterior and total corneal surfaces were significantly increased at 1 month compared with the baseline (p < 0.05) but gradually returned to the baseline by 3 months (p > 0.05). However, the change in posterior corneal aberration lasted up to 3 months (p < 0.05). There was a significant decrease in the corneal vortical nerve maximum length and average density after the operation (p < 0.05), and this damage lasted approximately 3 months. The corneal vortical nerve maximum length and average density were negatively correlated with the anterior corneal surface aberrations before and 1 month after the operation (correlation coefficients, CC = −0.26, −0.25, −0.28; all p < 0.05). Corneal vortex provided a unique site to observe long-term corneal nerve injury related to eye dryness. The continuous damage to the corneal vortical nerve may be due to the continuous dry eye state.
Collapse
Affiliation(s)
- Dalan Jing
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing 100191, China
| | - Xiaodan Jiang
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing 100191, China
| | - Xiaotong Ren
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing 100191, China
| | - Jie Su
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing 100191, China
| | - Shanshan Wei
- Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100069, China
| | - Ran Hao
- Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing 100069, China
| | - Yilin Chou
- Department of Ophthalmology, BenQ Medical Centre, The Affiliated BenQ Hospital of Nanjing Medical University, Nanjing 210017, China
- Correspondence: (Y.C.); (X.L.); Tel.: +86-18600862321 (Y.C.); +86-13911254862 (X.L.)
| | - Xuemin Li
- Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Rd., Haidian District, Beijing 100191, China
- Correspondence: (Y.C.); (X.L.); Tel.: +86-18600862321 (Y.C.); +86-13911254862 (X.L.)
| |
Collapse
|
17
|
Analysis of the Changes and Possible Reasons in Aberrations before and after Surgery in Patients with Concomitant Exotropia. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:5207553. [PMID: 36105630 PMCID: PMC9467761 DOI: 10.1155/2022/5207553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 07/21/2022] [Accepted: 08/16/2022] [Indexed: 11/17/2022]
Abstract
Objective. The objective is to observe the changes in aberrations before and after surgery in patients with common horizontal strabismus and to analyze the possible reasons for the changes. Methods. Forty eyes of 40 cases with concomitant exotropia who underwent strabismus correction at the Ophthalmology Department of Nantong University Hospital from October 2020 to July 2021 were included in this study, all of whom underwent unilateral lateral rectus recession combined with a medial rectus resection in the same eye. Aberration parameters were measured 1 day before surgery and 1 week, 1 month, 3 months, and 6 months after surgery. Differences in the indicators at each time period were compared by analysis of variance (ANOVA) of repeated measures data for a single factor, and data were analyzed using SPSS 25.0 statistical application software. Results. 5 mm pupil diameter: the preoperative and postoperative RMS of total aberration showed statistically significant difference (
). Postoperation test (Bonferroni method) and preoperative comparison at each period after surgery showed statistically significant differences between 6 months after surgery (
) and preoperative comparison. The preoperative and postoperative comparison of RMS in LOAs was statistically significant (
); postoperative test (Bonferroni method) and preoperative comparison showed that there were statistically significant differences between 1 week (
) and 6 months (
) after operation. The difference of RMS of defocus before and after operation was statistically significant (
); postoperation test (Bonferroni method) and preoperative comparison showed that there was statistically significant difference between 6 months after operation (
) and preoperative comparison. There was statistically significant difference in preoperative and postoperative RMS of HOAs (
). Postoperative test (Bonferroni method) and preoperative comparison showed that there was statistically significant difference 6 months after surgery (
). The RMS of secondary astigmatism showed a statistically significant difference before and after operation (
), and the postoperation test (Bonferroni method) showed a statistically significant difference 6 months after operation (
). In 5 mm pupil diameter, the preoperative and postoperative RMS of total aberration showed statistically significant difference (
), postoperative test (Bonferroni method) was used to compare each period after surgery with that before surgery, and there were statistically significant differences between 1 week after surgery (
), 3 months after surgery (
), and 6 months after surgery (
). The preoperative and postoperative comparison of RMS in LOAs was statistically significant (
), postoperative test (Bonferroni method) was used to compare each period after surgery with that before surgery, and there were statistically significant differences between 1 week after surgery (
), 3 months after surgery (
), and 6 months after surgery (
). The difference of RMS of defocus before and after surgery was statistically significant (
), and the comparison between postoperation test (Bonferroni method) and preoperation showed that the difference was statistically significant 6 months after surgery (
). The RMS of astigmatism showed statistically significant difference before and after operation (
), and the postoperation test (Bonferroni method) showed statistically significant difference between 6 months after operation (
) and before operation. Conclusion. We found that horizontal rectus surgery had a transient effect on LOAs and almost no effect on HOAs. Long-term follow-up is recommended after strabismus surgery to observe eye position and binocular visual function. Because of the high prevalence of strabismus in adolescents, long-term observation of the eye axis and aberration is recommended.
Collapse
|
18
|
Liao X, Wang MJ, Tan QQ, Lan CJ. Repeatability of i.Profiler for measuring wavefront aberrations in healthy eyes. Int Ophthalmol 2022; 42:2525-2531. [PMID: 35381898 DOI: 10.1007/s10792-022-02300-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 03/10/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To evaluate the repeatability of wavefront aberration measurements and the correlation between corneal aberration and pupil size in normal eyes using a wavefront-based autorefractor (i.ProfilerPlus; Carl Zeiss Vision, Germany). METHODS A prospective cross-sectional study. Wavefront aberrations, including spherical aberration (SA) (Z40), coma (Z3-1, Z31), trefoil (Z3-3, Z33) and total higher-order aberrations (tHOA), were measured at different pupil diameters. The repeatability was evaluated using one-way ANOVA method, and statistical indicators including within-subject standard deviation (Sw), test-retest repeatability (TRT), and intra-class correlation coefficient (ICC). The correlations between corneal aberrations and pupil sizes were evaluated by Pearson correlation analysis. RESULTS A total of 96 healthy young volunteers were enrolled. Corneal and ocular higher-order aberrations (HOA) measured by i.Profiler showed Sw < 0.01 μm, TRT < 0.10 μm, ICC > 0.90. There was a linear positive correlation between the corneal HOA and pupil size. The correlation coefficient between SA and tHOA was the largest (r = 0.996, P < 0.001). CONCLUSIONS The measurements of wavefront aberrations by i.Profiler are highly repeatable. Corneal HOA was significantly dependent on pupil size. SA was the most influential aberration for visual quality in this study.
Collapse
Affiliation(s)
- Xuan Liao
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, 1 Mao Yuan South Road, Nanchong, Sichuan, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong, Sichuan, China
| | - Mei-Jie Wang
- Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong, Sichuan, China
| | - Qing-Qing Tan
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, 1 Mao Yuan South Road, Nanchong, Sichuan, China.,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong, Sichuan, China
| | - Chang-Jun Lan
- Department of Ophthalmology, Affiliated Hospital of North Sichuan Medical College, 1 Mao Yuan South Road, Nanchong, Sichuan, China. .,Department of Ophthalmology and Optometry, North Sichuan Medical College, Nanchong, Sichuan, China.
| |
Collapse
|
19
|
Tear meniscus, corneal topographic and aberrometric changes after botulinum toxin-a injection in patients with blepharospasm and hemifacial spasm. Int Ophthalmol 2022; 42:2625-2632. [PMID: 35355169 DOI: 10.1007/s10792-022-02253-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 03/12/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE To investigate the effect of botulinum neurotoxin-A (BTX-A) treatment on dry eye symptoms, tear meniscus, corneal topography and corneal aberrometry in patients with benign essential blepharospasm (BEB) and hemifacial spasm (HFS). MATERIALS AND METHODS This prospective study comprised of 6 patients with BEB and 20 patients with HFS. Tear meniscus height (TMH) and depth (TMD), tear break-up time (TBUT), corneal fluorescein staining score (CFSS), Schirmer I test, ocular surface disease index (OSDI) score, corneal topography [corneal power of flat axis (K1), corneal power of steep axis (K2), mean corneal power (Km), astigmatism and thinnest pachymetry] and anterior corneal aberrometry [spherical aberration (SA), vertical coma (vcoma), horizontal coma (hcoma), higher order root mean square (hRMS) and total RMS] were evaluated before BTX-A treatment, 3 weeks after BTX-A treatment and 2 months after BTX-A treatment. RESULTS Six patients with BEB and 20 patients with HFS treated with BTX-A were evaluated in this study. Twenty contralateral spasm free eyes of 20 HFS patients were taken as control group. TMH and TMD were found to be significantly higher in eyes with spasm at both 3 weeks and 2 months after injection (TMH: 279.0 ± 123.2 at pretreatment, 380.5 ± 174.7 at third week and 317.0 ± 125.5 at second month p < 0.001 and p = 0.02, respectively), (TMD: 183.7 ± 59.7 at pretreatment, 235.7 ± 91.1 at third week and 209.8 ± 77.1 at second month p < 0.01 and p = 0.015, respectively). TBUT, CFSS, Schirmer I test values were similar (p > 0.05). OSDI scores decreased significantly from 29.6 ± 25.3 to 19.8 ± 20. p = 0.03 at third week and increased again by second month. K2 (43.9 ± 1.7 vs. 43.7 ± 1.6, p = 0.03) and astigmatism (0.8 ± 0.5 vs. 0.6 ± 0.4, p = 0.04) values were significantly lower at third week and increased again by second month. Pachymetry and aberrometric values did not change significantly. In the control group only Schirmer I test value decreased significantly at second month (10.5 ± 6.5 vs. 7.2 ± 5.6, p = 0.008), other parameters did not change. CONCLUSION BTX-A injection increases tear meniscus and decrease symptoms related to dry eye disease in BEB and HFS patients. It decrease astigmatism and keratometry values, it does not cause a significant change in corneal aberrations. However the positive effects of BTX-A injection on ocular surface is temporary.
Collapse
|
20
|
Gil A, Hernández CS, Nam AS, Varadaraj V, Durr NJ, Lim D, Dave SR, Lage E. Predicting subjective refraction with dynamic retinal image quality analysis. Sci Rep 2022; 12:3714. [PMID: 35260664 PMCID: PMC8904625 DOI: 10.1038/s41598-022-07786-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Accepted: 02/22/2022] [Indexed: 01/13/2023] Open
Abstract
The aim of this work is to evaluate the performance of a novel algorithm that combines dynamic wavefront aberrometry data and descriptors of the retinal image quality from objective autorefractor measurements to predict subjective refraction. We conducted a retrospective study of the prediction accuracy and precision of the novel algorithm compared to standard search-based retinal image quality optimization algorithms. Dynamic measurements from 34 adult patients were taken with a handheld wavefront autorefractor and static data was obtained with a high-end desktop wavefront aberrometer. The search-based algorithms did not significantly improve the results of the desktop system, while the dynamic approach was able to simultaneously reduce the standard deviation (up to a 15% for reduction of spherical equivalent power) and the mean bias error of the predictions (up to 80% reduction of spherical equivalent power) for the handheld aberrometer. These results suggest that dynamic retinal image analysis can substantially improve the accuracy and precision of the portable wavefront autorefractor relative to subjective refraction.
Collapse
Affiliation(s)
- Andrea Gil
- Department of Electronics and Communications Technology, Universidad Autónoma de Madrid, Madrid, Spain.,Instituto de Investigación Sanitaria Fundación Jiménez Díaz, Madrid, Spain.,PlenOptika, Inc., Boston, MA, USA
| | - Carlos S Hernández
- Department of Electronics and Communications Technology, Universidad Autónoma de Madrid, Madrid, Spain.,Instituto de Investigación Sanitaria Fundación Jiménez Díaz, Madrid, Spain.,PlenOptika, Inc., Boston, MA, USA
| | | | - Varshini Varadaraj
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Nicholas J Durr
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | | | | | - Eduardo Lage
- Department of Electronics and Communications Technology, Universidad Autónoma de Madrid, Madrid, Spain. .,Instituto de Investigación Sanitaria Fundación Jiménez Díaz, Madrid, Spain. .,PlenOptika, Inc., Boston, MA, USA.
| |
Collapse
|
21
|
Short Tear Breakup Time Could Exacerbate the Progression of Presbyopia in Women. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8159669. [PMID: 35127945 PMCID: PMC8816554 DOI: 10.1155/2022/8159669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 11/25/2021] [Accepted: 01/07/2022] [Indexed: 11/17/2022]
Abstract
Purpose The contributory factors and symptoms for presbyopia progression have not been fully determined. The purpose of the study was to compare presbyopia progression in subjects with short and normal tear breakup time and to explore the severity of common ocular symptoms associated with presbyopia progression. Method We conducted a clinic-based, retrospective, cross-sectional study. Inclusion criteria were bilateral phakic patients aged 40–69 years with best-corrected distance visual acuity better than 20/30, and exclusion criteria were the use of glaucoma eye drops, any disease affecting vision, or history of ocular surgery. We measured the binocular near add power and compared the results using Kaplan-Meier analysis. Association between near add power and ocular symptoms was explored. Results There were 1411 participants (mean age of 50.1 years). There were no significant differences in age, intraocular pressure, spherical equivalent, astigmatism, or anisometropia between the sexes. Kaplan-Meier analysis indicated that women with short tear breakup time reached the endpoint (near add power of +3.00 D) significantly earlier than those with normal tear breakup time (P = 0.043; Cox-Mantel test). Eye fatigue was most severe in the group with an add power of 1.25-2.00 D. Near add power was correlated with hyperopia, astigmatic errors, and anisometropia. Conclusions This study suggests an exacerbation of presbyopia progression in women with short tear breakup time. Eye fatigue was most severe in those with an add power of 1.25-2.00 D.
Collapse
|
22
|
The Effect of Rebamipide on Refractive Accuracy of Cataract Surgery in Patients with Dry Eye. Ophthalmol Ther 2022; 11:603-611. [PMID: 35064909 PMCID: PMC8927481 DOI: 10.1007/s40123-022-00457-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 01/06/2022] [Indexed: 12/18/2022] Open
Abstract
Introduction Refractive accuracy is crucial for increasing patient satisfaction after cataract surgery. Tear film instability caused by dry eye can lead to inaccurate measurement of corneal power, which is one of the most important factors for postoperative refractive calculation. This study investigated the effect of 2% rebamipide ophthalmic suspension on the predicted refractive accuracy for cataract surgery in patients with dry eye. Methods This single-center, prospective, open-label study included 35 dry eyes (with tear breakup time < 5 s) who underwent cataract surgery. The patients were treated with rebamipide for 4 weeks before the preoperative examination. In addition to the usual evaluation of biometric variables essential for cataract surgery, tear breakup time (TBUT), superficial punctate keratopathy in the central part of the cornea (C-SPK), corneal higher-order aberrations (HOAs), and predicted postoperative spherical equivalent (P-SE) were evaluated at baseline and 4 weeks after dry eye treatment. The patients’ subjective spherical equivalent (S-SE) was evaluated 1 month postoperatively. The difference between S-SE and P-SE was used to assess the accuracy of the P-SE. Improvement in TBUT, C-SPK, HOA, and the accuracy of P-SE after dry eye treatment were analyzed. Results The accuracy of the biometry readings for the achieved P-SE was within 0.25 D in 42.9% and 54.3%; within 0.5 D in 71.4% and 88.6%; and within 0.75 D in 88.6% and 97.1% of eyes before and after rebamipide treatment, respectively (p < 0.01). TBUT, C-SPK, and HOAs significantly improved after rebamipide treatment (p < 0.01). Conclusion Rebamipide significantly improved the corneal surface condition and accuracy of the predicted postoperative refraction in dry eyes. Supplementary Information The online version contains supplementary material available at 10.1007/s40123-022-00457-3.
Collapse
|
23
|
Zhao S, Le Q. Analysis of the first tear film break-up point in Sjögren's syndrome and non-Sjögren's syndrome dry eye patients. BMC Ophthalmol 2022; 22:1. [PMID: 34980014 PMCID: PMC8722312 DOI: 10.1186/s12886-021-02233-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 12/23/2021] [Indexed: 11/19/2022] Open
Abstract
Background Tear film instability plays an important role in the course of Sjögren’s Syndrome dry eye (SSDE) even though it is generally classified as aqueous-deficient dry eye. The measurement of the first tear film break-up point (FTBUP) helps to evaluate the most unstable position of the tear film on ocular surface. We aim to investigate FTBUP in Sjögren’s Syndrome dry eye (SSDE) and non-Sjögren’s Syndrome dry eye (NSSDE) patients, and explore its correlation with dry eye indices. Methods Twenty-two SSDE patients (44 eyes) and 22 NSSDE patients (44 eyes) were enrolled in the study. Oculus Keratograph K5M was used to measure FTBUP, the first and average non-invasive keratographic breakup time (f-NIKBUT and av-NIKBUT), the tear meniscus height, and meibomian gland dropout. Other tests of tear film were also performed including Ocular Surface Dryness Index (OSDI), Schirmer I test, fluorescein break-up time and corneal fluorescein staining. Dry eye indices and the locations of the FTBUP were compared between SSDE and NSSDE patients. Generalized estimating equation (GEE) was used to ajusted the correlations between right and left eyes. The correlations between the FTBUP and ocular symptoms and signs were investigated using Pearson’s correlation coefficient test. Results The FTBUP occurred at the supranasal quadrant in 12/88 eyes, supratemporal quadrant in 8/88 eyes, inferonasal quadrant in 34/88 eyes, and inferotemporal quadrant in 34/88 eyes. The percentage eyes with inferior FTBUP was significantly higher in the SSDE than in the NSSDE subjects (86.3% vs 68.1%, P = .049). Moreover, in SSDE subjects, temporal breakup point was seen more often in those who presented corneal fluorescein staining in any location, while nasal breakup point was more frequent in those who did not present any corneal fluorescein staining (P = .045). Conclusion The location of the FTBUP in SSDE patients had specific characteristics. However, the diagnostic potential of FTBUP in early recognition of SSDE needs further validation.
Collapse
Affiliation(s)
- Songjiao Zhao
- Department of Ophthalmology, Eye, Ear, Nose & Throat Hospital of Fudan University, No. 83 Fen Yang Rd, Shanghai, 200031, China
| | - Qihua Le
- Department of Ophthalmology, Eye, Ear, Nose & Throat Hospital of Fudan University, No. 83 Fen Yang Rd, Shanghai, 200031, China. .,Research Center, Eye, Ear, Nose & Throat Hospital of Fudan University, Shanghai, China. .,Myopia Key Laboratory of Ministry of Health, Eye, Ear, Nose & Throat Hospital of Fudan University, Shanghai, China.
| |
Collapse
|
24
|
Fan Q, Wang H, Kong W, Zhang W, Li Z, Wang Y. Online Learning-Related Visual Function Impairment During and After the COVID-19 Pandemic. Front Public Health 2021; 9:645971. [PMID: 34912766 PMCID: PMC8666689 DOI: 10.3389/fpubh.2021.645971] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Accepted: 10/29/2021] [Indexed: 01/06/2023] Open
Abstract
This study aimed to review the consequences of increased online learning, which was precipitated by the coronavirus disease 2019 (COVID-19), on visual function, as well as the methods for preventing the associated visual impairment. The recent finding implies that a higher incidence of myopia may be observed during the pandemic than that before. The myopia prevalence was 59.35% in COVID-19, which was higher than that in the normal period. COVID-19-related influence of developing myopia among students should be addressed and under control. Online learning precipitated by COVID-19 is likely to increase the global burden of visual function impairment. This review highlighted useful measures to prevent online learning-related visual function impairments, including the following: (1) desktop illumination of no >300 lx, online learning time for primary, and middle-school students of no more than 20–30 min per session; (2) daily video time for preschool children not exceeding 1 h, and for school-age children and adolescents not exceeding 2 h; (3) after every 30–40 min of online learning, moving eyes away from the screen or closed for 10 min; (4) engaging in outdoor activities for ≥ 2 h a day; (5) suitable screen and learning environment settings and correct postures for reading and writing; (6) sufficient sleep and proper nutrition. Preventing online learning-related visual impairment during and after this unprecedented pandemic will facilitate future ophthalmic practice.
Collapse
Affiliation(s)
- Qian Fan
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital and Eye Institute, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology Tianjin Medical University, Tianjin, China
| | - Hongxia Wang
- Shanghai Guanghua Integrated Traditional Chinese and Western Medicine Hospital, Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Wenjun Kong
- Beijing You'an Hosptial, Capital Medical University, Beijing, China
| | - Wei Zhang
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital and Eye Institute, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology Tianjin Medical University, Tianjin, China
| | - Zhouyue Li
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | - Yan Wang
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital and Eye Institute, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology Tianjin Medical University, Tianjin, China
| |
Collapse
|
25
|
Tutchenko L, Patel S, Skovron M, Horak O, Voytsekhivskyy O. The relationship between angle kappa and astigmatism after phacoemulsification with implanting of spherical and aspheric intraocular lens. Indian J Ophthalmol 2021; 69:3503-3510. [PMID: 34826984 PMCID: PMC8837301 DOI: 10.4103/ijo.ijo_572_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Purpose: To determine the significance of any association between either change in angle kappa (K°) or the rectilinear displacement (L, mm) of the first Purkinje image relative to the pupil center and unexpected changes in astigmatism after phacoemulsification. Methods: Orbscan II (Bausch and Lomb) measurements were taken at 1, 2, and 3 months after unremarkable phacoemulsification in patients implanted with spherical (group 1, SA60AT, Alcon) or aspheric (group 2, SN60WF, Alcon) nontoric IOLs. The outputs were used to calculate L. Astigmatism, measured by autorefractometry and subjective refraction, was subjected to vector analysis (polar and cartesian formats) to determine the actual change induced over the periods 1–2 and 2–3 months postop. Results: Chief findings were that the mean (n, ±SD, 95%CI) values for L over each period were as follows: Group 1, 0.407 (38, ±0.340, 0.299–0.521), 0.315 (23, ±0.184, 0.335–0.485); Group 2, 0.442 (45, ±0.423, 0.308–0.577), 0.372 (26, ±0.244, 0.335–0.485). Differences between groups were not significant. There was a significant linear relationship between (A) the change in K (ΔK = value at 1 month-value at 2 months) and K at 1 month (x), where ΔK =0.668-3.794X (r = 0.812, n = 38, P = <0.001) in group 1 and ΔK = 0.263x -1.462 (r = 0.494, n = 45, P = 0.002) in group 2, (B) L and the J45 vector describing the actual change in astigmatism between 1 and 2 months in group 2, where J45 (by autorefractometry) =0.287L-0.160 (r = 0.487, n = 38, P = 0.001) and J45 (by subjective refraction) =0.281L-0.102 (r = 0.490, n = 38, P = 0.002), and (C) J45 and ΔK between 2 and 3 months in group 2, where J45 (by subjective refraction) =0.086ΔK-0.063 (r = 0.378, n = 26, P = 0.020). Conclusion: Changes in the location of the first Purkinje image relative to the pupil center after phacoemulsification contributes to changes in refractive astigmatism. However, the relationship between the induced change in astigmatism resulting from a change in L is not straightforward.
Collapse
Affiliation(s)
- Larysa Tutchenko
- Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine
| | - Sudi Patel
- Department of Ophthalmology, Specialty Eye Hospital Svjetlost, Zagreb, Croatia
| | - Mykhailo Skovron
- Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine
| | - Olha Horak
- Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine
| | - Oleksiy Voytsekhivskyy
- Department of Ophthalmology, Kyiv City Clinical Ophthalmological Hospital, Eye Microsurgical Center, Kyiv, Ukraine
| |
Collapse
|
26
|
A Systematic Review on the Association Between Tear Film Metrics and Higher Order Aberrations in Dry Eye Disease and Treatment. Ophthalmol Ther 2021; 11:35-67. [PMID: 34762259 PMCID: PMC8770783 DOI: 10.1007/s40123-021-00419-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 10/29/2021] [Indexed: 12/05/2022] Open
Abstract
We systematically reviewed published research on dry eye disease and its association with higher order aberrations (HOAs). The purpose of this review was to first determine if an association between tear film metrics and HOAs exists and second to determine if the treatment of dry eyes can improve tear film metrics and HOAs together. A search was conducted in Entrez PubMed on 25 April 2021 using the keywords “higher order aberrations” and “dry eye”. The initial search yielded 61 articles. After publications were restricted to only original articles measuring HOA outcomes in patients with dry eye, the final yield was 27 relevant articles. Of these 27 papers, 12 directly looked at associations and correlations between dry eyes and HOA parameters. The remaining 15 studies looked at dry eye interventions and HOA outcomes and parameters. There is clear evidence demonstrating that dry eyes and HOAs have an association, and that the tear film is one of the most important factors in this relationship. There is also a direct correlation between tear film metrics and HOAs. Improvements in HOAs with dry eye interventions provide further evidence to support the intricate relationship between the two. Despite the clear association between HOAs and dry eye disease, further research is still required in the realm of clinical application as dry eye interventions vary depending on many factors, including patient severity and eye drop viscosity.
Collapse
|
27
|
Teshigawara T, Meguro A, Mizuki N. Effects of Rebamipide on Differences in Power and Axis of Corneal Astigmatism Between Two Intra-patient Keratometric Measurements in Dry Eyes. Ophthalmol Ther 2021; 10:891-904. [PMID: 34292514 PMCID: PMC8589897 DOI: 10.1007/s40123-021-00368-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 06/23/2021] [Indexed: 11/28/2022] Open
Abstract
Introduction This study investigated the effect of rebamipide on discrepancies in the power and axis of astigmatism between two intra-patient keratometric measurements in patients with dry eyes. Methods Fifty-eight dry eyes (with a short tear breakup time [TBUT] of less than 5 s) were analyzed. Patients with dry eye were treated with 2% rebamipide ophthalmic suspension (group R) or Mytear® artificial tear ophthalmic solution (group M) for 4 weeks. TBUT and corneal higher-order aberrations (HOAs) were evaluated at baseline and 4 weeks after treatment. Astigmatism power and axis were measured twice during both evaluations, at 5-min intervals. Baseline and post-treatment measurements were compared. Changes in TBUT and HOAs, and intra-patient discrepancies in astigmatism power and axis measurements were evaluated. Results HOAs showed significant positive correlations with intra-patient differences in astigmatism power and axis (P < 0.001). At the 4-week post-treatment follow-up, TBUT increased, and HOAs and astigmatism power and axis discrepancies decreased in a significant number of patients in group R (P < 0.001). In group M, only differences in astigmatism power decreased in a significant number of cases (P = 0.005). The degree of change in the intra-patient difference in astigmatism power between the two post-treatment keratometric measurements was significantly greater in group R than in group M (P < 0.001). In group R, baseline HOAs exhibited a significant positive correlation with changes in HOAs and intra-patient differences in astigmatism power (both P < 0.001). In group M, baseline HOAs were only significantly correlated with changes in intra-patient differences in astigmatism power (P = 0.030). Conclusion In dry eyes with short TBUTs, rebamipide significantly improved the corneal surface condition and significantly reduced intra-patient discrepancies in astigmatism power and axis measurements. Rebamipide may improve the accuracy of intraocular lens (IOL) power calculations in dry eyes, particularly when toric IOLs are implanted. Supplementary Information The online version contains supplementary material available at 10.1007/s40123-021-00368-9. This study investigated the effect of rebamipide on discrepancies in power and axis of astigmatism between two intra-patient keratometric measurements in patients with dry eyes. Short tear break-up time and corneal high-order aberrations were evaluated at baseline and 4 weeks after treatment. Astigmatism power and axis were measured twice at both evaluations. Baseline and post-treatment measurements were compared, and changes in short tear break-up time and high-order aberrations, as well as intra-patient discrepancies in astigmatism power and axis measurements, were evaluated. High-order aberrations at baseline showed significant positive correlations with intra-patient differences in astigmatism power and axis. Rebamipide significantly improved the corneal surface condition and significantly reduced intra-patient discrepancies in astigmatism power and axis measurements. Rebamipide may improve the accuracy of intraocular lens power calculations in dry eyes, particularly when toric intraocular lenses are implanted.
Collapse
Affiliation(s)
- Takeshi Teshigawara
- Department of Ophthalmology, Yokosuka Chuoh Eye Clinic, 2-6 Odaki-cho, Yokosuka, 238-0008, Kanagawa, Japan. .,Tsurumi Chuoh Eye Clinic, 1-2-1 Tsurumi-chuo, Tsurumi, Yokohama, 230-0051, Kanagawa, Japan. .,Department of Ophthalmology, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa, Yokohama, 236-0004, Kanagawa, Japan.
| | - Akira Meguro
- Department of Ophthalmology, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa, Yokohama, 236-0004, Kanagawa, Japan
| | - Nobuhisa Mizuki
- Department of Ophthalmology, Yokohama City University School of Medicine, 3-9 Fukuura, Kanazawa, Yokohama, 236-0004, Kanagawa, Japan
| |
Collapse
|
28
|
Messmer EM. Funktionelle Sehschärfe beim Trockenen Auge. SPEKTRUM DER AUGENHEILKUNDE 2021. [DOI: 10.1007/s00717-021-00489-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
ZusammenfassungDas Trockene Auge führt häufig zu Sehstörungen trotz guter Sehleistung in der Standardvisusprüfung. Die Beschwerden treten meist beim Lesen, Arbeiten am Computer und/oder beim Autofahren auf. Grund ist die schlechte optische Qualität der Augenoberfläche beim Trockenen Auge mit Zunahme von topometrischer Irregularität und Asymmetrie, Anstieg des irregulären Astigmatismus, Zunahme der kornealen und okulären Aberrationen höherer Ordnung, Abnahme der Kontrastsensitivität und Zunahme der Lichtstreuung. Die funktionelle Sehschärfe repräsentiert die Visusfunktion im Zeitverlauf und reflektiert die Visusleistung eines Individuums bei täglichen Aktivitäten. Sie ist beim Trockenen Auge signifikant reduziert im Vergleich zu Normalprobanden. Eine Vielzahl von Testmethoden zur Evaluierung der funktionellen Sehschärfe wurde beschrieben. Kein Verfahren hat sich bisher in der täglichen Praxis durchgesetzt.
Collapse
|
29
|
Analysis of Tear Ferning Patterns in Young Female Subjects with Refractive Errors. J Ophthalmol 2021; 2021:9524143. [PMID: 33552597 PMCID: PMC7847330 DOI: 10.1155/2021/9524143] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 01/08/2021] [Accepted: 01/13/2021] [Indexed: 01/10/2023] Open
Abstract
To evaluate the dry eye symptoms and ocular tear film in young female subjects with refractive errors (RE) using the ocular surface disease index (OSDI), phenol red thread (PRT) and tear ferning (TF) tests. Methods. A group of 50 young female subjects (mean ± standard division = 20.3 ± 1.1 years) with RE (−0.25 to −6.00D) completed the study. An age-matched control group consisting of 50 healthy normal eye female subjects (22.2 ± 1.5 years) was recruited for comparison. The OSDI was completed first, followed by PRT and TF tests. Results. Median OSDI and TF scores were significantly higher (Mann–Whitney test; P < 0.001) among the study group subjects [median (interquartile range (IQR)) = 13.5 (15.3) and 1.6 (1.3), respectively] compared to the control group [6.0 (4.0) and 0.9 (0.8), respectively], whereas the median PRT score was significantly lower (Mann–Whitney test; P=0.003) in the study group [(27.5 (6.3) mm] compared to the control group [29.5 (5.0) mm]. For subjects within the mild RE group (N = 30), significant differences (Mann–Whitney test, P < 0.001 to 0.005) were found between the median OSDI, PRT, and TF scores and those recorded within the control group. For the subjects with moderate RE (N = 20), significant differences (Mann–Whitney test, P < 0.001 to 0.002) were found between the median OSDI and TF scores, and those recorded within the control group. Conclusion. The presence of RE in young females has a negative effect on tear film in terms of dry eye symptoms, tear volume, and TF grades. Dry eye symptoms experienced by subjects with RE and the TF grades were significantly higher compared with the control group. In addition, the tear volume was significantly lower in the study group. Clearly, RE has a risk factor for dry eye.
Collapse
|
30
|
Yeung L, Lai CC, Chen SN, Cheng CK, Yang CM, Hsieh YT, Tsai A, Yang CH. Comparison of visual outcomes between therapy choices and subtypes of polypoidal choroidal vasculopathy (PCV) in Taiwan: a real-world study. Sci Rep 2021; 11:470. [PMID: 33432090 PMCID: PMC7801625 DOI: 10.1038/s41598-020-80731-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Accepted: 12/21/2020] [Indexed: 11/30/2022] Open
Abstract
Polypoidal choroidal vasculopathy (PCV) is a distinctive type of neovascular age-related macular degeneration prevalent in many Asian countries. However, there is still some controversy in how the subtypes of PCV are classified. This post-hoc study redefined the branching vascular network (BVN) and PCV subtypes through retrospective review of indocyanine green angiography (ICGA) and fluorescein angiography images from two observational studies (RENOWNED/REAL). Of the visual outcomes for each angiographic subtype and treatment pattern investigated, BVN was identified in 56.3% of PCV patients. The proportions and features of the re-defined PCV subtypes were 43.8%, 10.4%, and 45.8% for subtype A (without distinctive features of BVN), B (with BVN but no leakage), and C (with BVN and leakage), respectively. Subtype A had better visual outcomes when compared to subtype C. This possibly resulted from a better baseline visual acuity in subtype A. Moreover, combination therapy [photodynamic therapy plus anti-vascular endothelial growth factor (VEGF)] may lead to better visual improvement than mono-anti-VEGF treatment alone. This study provides the prevalence of PCV subtypes in Taiwan and may serve as a reference for PCV treatment strategies in a real-world setting, especially for the combination therapy and patients without distinctive features of BVN.
Collapse
Affiliation(s)
- Ling Yeung
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Keelung City, Taiwan
| | - Chi-Chun Lai
- Department of Ophthalmology, Chang Gung Memorial Hospital, Keelung, Keelung City, Taiwan
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, Taoyuan City, Taiwan
| | - San-Ni Chen
- Department of Ophthalmology, Changhua Christian Hospital, Changhua City, Taiwan
| | - Cheng-Kuo Cheng
- Department of Ophthalmology, Shin Kong Wu Ho-Su Memorial Hospital, Shilin District, Taipei City, Taiwan
| | - Chung-May Yang
- Department of Ophthalmology, School of Medicine, National Taiwan University Hospital, No. 7, Zhongshan South Road, Zhongzheng District, Taipei City, 100, Taiwan
| | - Yi-Ting Hsieh
- Department of Ophthalmology, School of Medicine, National Taiwan University Hospital, No. 7, Zhongshan South Road, Zhongzheng District, Taipei City, 100, Taiwan
| | - Arslan Tsai
- Clinical Development and Medical Affairs, Novartis Taiwan, Taipei City, Taiwan
| | - Chang-Hao Yang
- Department of Ophthalmology, School of Medicine, National Taiwan University Hospital, No. 7, Zhongshan South Road, Zhongzheng District, Taipei City, 100, Taiwan.
| |
Collapse
|
31
|
Abstract
PURPOSE OF REVIEW There are several different approaches to handling regular and irregular astigmatism during cataract surgery, but still much debate on which solutions are most effective given unique patient circumstances. In this review, we examine recent literature and studies to highlight some of the most effective ways to plan preoperatively, manage regular and irregular astigmatism during cataract surgery, as well as managing postoperative complications. RECENT FINDINGS Recent developments in technology have provided increased courses of action for astigmatism management during cataract surgery. Additional options of toric IOLs with presbyopic platforms, light adjustable lenses, intraocular pinhole lenses, online technological tools and platforms, wavefront or topographic laser technology, and phototherapeutic keratectomy are all effective solutions to managing regular and irregular astigmatism. In this review, we will explore optimal approaches for unique situations. SUMMARY With increased technology, research, and methods, correcting regular and irregular astigmatism during cataract surgery is achievable in most patients. With in-depth preoperative planning, analysis of patient-specific factors, and a tailored approach, surgeons can obtain excellent uncorrected vision for patients.
Collapse
|
32
|
Pavlatos E, Huang D, Li Y. Eye motion correction algorithm for OCT-based corneal topography. BIOMEDICAL OPTICS EXPRESS 2020; 11:7343-7356. [PMID: 33409001 PMCID: PMC7747916 DOI: 10.1364/boe.412209] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/18/2020] [Accepted: 11/19/2020] [Indexed: 05/30/2023]
Abstract
With its sequential image acquisition, OCT-based corneal topography is often susceptible to measurement errors due to eye motion. We have developed a novel algorithm to detect eye motion and minimize its impact on OCT topography maps. We applied the eye motion correction algorithm to corneal topographic scans acquired using a 70 kHz spectral-domain OCT device. OCT corneal topographic measurements were compared to those from a rotating Scheimpflug camera topographer. The motion correction algorithm provided a 2-4 fold improvement in the repeatability of OCT topography and its agreement with the standard Scheimpflug topographer. The repeatability of OCT Zernike-based corneal mean power, cardinal astigmatism, and oblique astigmatism after motion detection was 0.14 D, 0.28 D, and 0.24 D, respectively. The average differences between the two devices were 0.19 D for simulated keratometry-based corneal mean power, 0.23 D for cardinal astigmatism, and 0.25 D for oblique astigmatism. Our eye motion detection method can be applied to any OCT device, and it therefore represents a powerful tool for improving OCT topography.
Collapse
|
33
|
Guo OD LW, Akpek E. The negative effects of dry eye disease on quality of life and visual function. Turk J Med Sci 2020; 50:1611-1615. [PMID: 32283910 PMCID: PMC7672346 DOI: 10.3906/sag-2002-143] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 04/12/2020] [Indexed: 02/04/2023] Open
Abstract
In recent years, dry eye has become a hot topic within ophthalmology and optometry, especially in regards to new frontiers in treatment modalities which include novel devices, procedures, and medications. However, some of the more understudied areas in dry eye involve its impact on quality of life. Although ocular discomfort symptoms are well known to be associated with dry eye, its negative effects on visual function remain underrecognized. This paper reviews these topics within the currently published literature to heighten awareness among clinicians.
Key Words: D
ry eye, quality of life, visual function, functional visual acuity, patient questionnaire, OSDI, SPEED, SANDE, IDEEL, NEI VFQ-25
Collapse
Affiliation(s)
- Lee W Guo OD
- Department of Ocular Surface Diseases and Dry Eye Clinic, The Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA
| | - Esen Akpek
- Department of Ocular Surface Diseases and Dry Eye Clinic, The Wilmer Eye Institute, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
34
|
Negishi K, Ayaki M, Uchino M, Takei K, Tsubota K. Strip Meniscometry Correlates With Ocular Surface Tests and Symptoms. Transl Vis Sci Technol 2020; 9:31. [PMID: 33262905 PMCID: PMC7691796 DOI: 10.1167/tvst.9.12.31] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 10/26/2020] [Indexed: 12/22/2022] Open
Abstract
Purpose The aim of this study was to investigate the association of dry eye disease (DED)-related signs and symptoms with two tear function tests. Methods This was a clinic-based, cross-sectional study with recruitment of consecutive participants. Schirmer test (ST), tear strip meniscometry (SM), and fluorescein tear breakup time were measured and corneal staining score was examined in outpatients at three clinics. Seven subjective symptoms were assessed by interview, including dryness, irritation, pain, lacrimation, fatigue, blurring, and photophobia. Statistical analyses included regression analysis and comparison tests. Results The mean age of the 210 participants was 61.2 ± 15.2 years (range, 12-91 years), with 135 women (64.3%) in the cohort. The mean ST value was 12.9 ± 9.3 (0-35) mm, and SM was 2.5 ± 1.6 (0-10) mm, with no difference between women and men. SM values were lower in the presence of irritation (P = 0.046) and photophobia (P = 0.011). Regression analysis revealed ST and SM values were strongly correlated (β = 0.255, P < 0.001). SM was significantly correlated with breakup time (β = 0.149, P = 0.032), whereas there was no correlation between ST and DED-related signs and symptoms. Conclusions SM was correlated with DED-related symptoms and breakup time, whereas ST was not. A low SM value could be an alternative clinical parameter to determine tear film-oriented therapy. Translational Relevance Tear strip meniscometry could be a useful tear function examination on a routine clinical basis since it is a 5-second noninvasive procedure and associated with subjective symptoms and the value of the conventional Schirmer test.
Collapse
Affiliation(s)
- Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Masahiko Ayaki
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- Otake Clinic Moon View Eye Center, Kanagawa, Japan
| | - Miki Uchino
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | | | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
- Tsubota Laboratory, Inc., Tokyo, Japan
| |
Collapse
|
35
|
Subjective Happiness and Satisfaction in Postoperative Anisometropic Patients after Refractive Surgery for Myopia. J Clin Med 2020; 9:jcm9113473. [PMID: 33126654 PMCID: PMC7693991 DOI: 10.3390/jcm9113473] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 10/25/2020] [Accepted: 10/27/2020] [Indexed: 01/01/2023] Open
Abstract
Laser-assisted in situ keratomileusis (LASIK) contributes to increased patient happiness one month after surgery; however, longer term effects are unknown. We performed a retrospective cross-sectional study on 472 patients who underwent bilateral LASIK surgery to measure happiness and satisfaction with LASIK, and to identify affecting factors. Patients completed questionnaires on satisfaction with the surgery and the subjective happiness scale (SHS) before, and 1, 3, 6, and 12 months after surgery. Multiple regression analyses were performed to determine independent predictors of SHS and satisfaction scores. Mean SHS increased at one month but was similar to baseline levels by six months. The SHS of older patients was greater than younger ones at baseline and at one and three months, while satisfaction among the older group was poorer at one and three months. Multiple regression analyses revealed that the decrease in SHS score from one month to three months correlated with baseline SHS, SHS at one month, uncorrected distance visual acuity (UDVA), and age. Regression analysis revealed SHS at six months correlated with preoperative SHS, SHS at one month, and satisfaction at six months. Satisfaction at final visit correlated with age, UDVA, anisometropia, and with SHS at each visit. We conclude that happiness and satisfaction were age- and UDVA-dependent, and anisometropic patients report poorer satisfaction scores.
Collapse
|
36
|
Naderi K, Gormley J, O’Brart D. Cataract surgery and dry eye disease: A review. Eur J Ophthalmol 2020; 30:840-855. [PMID: 32515220 PMCID: PMC7549290 DOI: 10.1177/1120672120929958] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 05/07/2020] [Indexed: 01/26/2023]
Abstract
AIM To review published literature concerning cataract surgery and dry eye disease (DED). METHODS A search was undertaken using the following: PubMed (all years), Web of Science (all years), Ovid MEDLINE(R) (1946 to 12 December 2019), Ovid MEDLINE(R) Daily Update 10 December 2019, MEDLINE and MEDLINE non-indexed items, Embase (1974-2019, week 49), Ovid MEDLINE (R) and Epub Ahead of Print, In-Process and Other Non-Indexed Citations and Daily (1946 to 12 December 2019), CENTRAL (including Cochrane Eyes and Vision Trials Register; Cochrane Library: Issue 12 of 12 December 2019), metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and WHO International Clinical Trials Registry Platform (www.who.int/ictrp/search/en). Search terms included 'cataract surgery', 'phacoemulsification' and 'cataract extraction', combined with 'dry eyes' and 'ocular surface'. Relevant in-article references not returned in our searches were also considered. RESULTS Publications identified included systematic reviews, meta-analysis, randomized controlled trials, cohort studies, case series and laboratory-based studies. Published data highlighting the burden of DED both prior and following cataract surgery were reviewed as well as studies highlighting the effects of cataract surgery on the ocular surface, intra-operative measures to reduce deleterious effects on the ocular surface and current evidence on the management options of post-operative DED. CONCLUSIONS DED is common and can be exacerbated by cataract surgery. Ophthalmologists need to assess for pre-existing DED and instigate treatment before surgery; be aware of reduced accuracy of measurements for surgical planning in the presence of DED; limit intra-operative surgical factors damaging to the ocular surface; and consider management to reduce DED post-operatively.
Collapse
Affiliation(s)
- Khayam Naderi
- Department of Ophthalmology, Guy’s and St Thomas’ NHS Foundation
Trust, London, UK
- King’s College London, London, UK
| | - Jack Gormley
- Department of Ophthalmology, Guy’s and St Thomas’ NHS Foundation
Trust, London, UK
| | - David O’Brart
- Department of Ophthalmology, Guy’s and St Thomas’ NHS Foundation
Trust, London, UK
- King’s College London, London, UK
| |
Collapse
|
37
|
Pflugfelder SC, Stern ME. Biological functions of tear film. Exp Eye Res 2020; 197:108115. [PMID: 32561483 DOI: 10.1016/j.exer.2020.108115] [Citation(s) in RCA: 117] [Impact Index Per Article: 29.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 06/05/2020] [Accepted: 06/08/2020] [Indexed: 02/06/2023]
Abstract
Tears have a vital function to protect and lubricate the ocular surface. Tear production, distribution and clearance is tightly regulated by the lacrimal functional unit (LFU) to meet ocular surface demands. The tear film consists of an aqueous-mucin layer, containing fluid and soluble factors produced by the lacrimal glands and mucin secreted by the goblet cells, that is covered by a lipid layer. The array of proteins, glycoproteins and lipids in tears function to maintain a stable, well-lubricated and smooth optical surface. Tear factors also promote wound healing, suppress inflammation, scavenge free radicals, and defend against microbial infection. Disease and dysfunction of the LFU leads to tear instability, increased evaporation, inflammation, and blurred and fluctuating vision. The function of tear components and the consequences of tear deficiency on the ocular surface are reviewed.
Collapse
Affiliation(s)
- Stephen C Pflugfelder
- Department of Ophthalmology, Baylor College of Medicine, Houston, TX, United States.
| | - Michael E Stern
- Department of Ophthalmology, Baylor College of Medicine, Houston, TX, United States; ImmunEyez, Mission Viejo, CA, United States.
| |
Collapse
|
38
|
Loss of Concentration May Occur by Blink Inhibition in DED Simulation Models. Life (Basel) 2020; 10:life10050061. [PMID: 32414123 PMCID: PMC7281572 DOI: 10.3390/life10050061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/12/2020] [Accepted: 05/12/2020] [Indexed: 01/08/2023] Open
Abstract
Purpose: Patients with dry eye disease (DED) often suffer productivity loss and distress due to bothersome symptoms. The aim of this study was to objectively quantify and compare productivity-related emotional states obtained from brain waveforms in natural and simulated DED conditions. Method: 25 healthy adults (6 females and 19 males; mean age ± standard deviation, 22.6 ± 8.3 years) were recruited for the study, which included an electroencephalogram (EEG), measurements of interblinking time, and questionnaires. DED was simulated by suppressing blinking, while spontaneous blinking served as a control. Elements of concentration, stress, and alertness were extracted from the raw EEG waveforms and the values were compared during spontaneous and suppressed blinking. The relation with DED-related parameters was then explored. Written informed consent was obtained from all participants. Results: All participants successfully completed the experimental protocol. Concentration significantly decreased during suppressed blinking in 20 participants (80%), when compared with spontaneous blinking, whereas there were no or small differences in stress or alertness between spontaneous and suppressed blinking. The change in concentration was correlated with interblinking time (β = −0.515, p = 0.011). Conclusion: Loss of concentration was successfully captured in an objective manner using the EEG. The present study may enable us to understand how concentration is affected during blink suppression, which may happen in office work, particularly during computer tasks. Further study using detailed ocular evaluation is warranted to explore the effect of different interventions.
Collapse
|
39
|
Normalized ocular surface temperature models for tear film characteristics and dry eye disease evaluation. Ocul Surf 2020; 19:74-82. [PMID: 32298795 DOI: 10.1016/j.jtos.2020.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 02/25/2020] [Accepted: 04/04/2020] [Indexed: 11/21/2022]
Abstract
PURPOSE To construct normalized ocular surface temperature (NOST) models for different tear film characteristics and evaluate its potential in dry-eyes screening. METHODS We included 227 right eyes of 227 patients. Tear film characteristics were categorized into 4 types according to fluorescein tear film breakup time (FTBUT) and Schirmer test results, namely type 1: FTBUT >5 s and Schirmer >5 mm; type 2: FTBUT ≤5 s and Schirmer >5 mm; type 3: FTBUT ≤5 s and Schirmer ≤5 mm; and type4: FTBUT >5 s and Schirmer ≤5 mm. Ocular surface temperature was measured by a video-thermographer. Mean temperatures of the central cornea were calculated from the videos of each frame during the 4-s blink interval. We first constructed individual NOST model for every tear characteristic. Participants were included for further analysis when their OSDI was ≥23, FTBUT ≤5 s, and Schirmer >5 mm. They were subdivided into short-BUT and short BUT with SPK subgroups according to the absence or presence of corneal fluorescein-stain. The NOST models of the normal, short-BUT and short BUT with SPK groups were separately constructed and the potential of screening analyzed via ROC curves. RESULTS Each tear film type had a different NOST model. At 3 s after blinking, the order of NOST was type 4 >type 1 >type 3 >type 2. In dry-eye screening, the NOST was normal > short-BUT > short BUT with SPK. The NOST displayed a sensitivity 0.87, specificity 0.80, and AUC 0.88 for diagnosing short BUT with SPK. CONCLUSION NOST models are useful in differentiating tear film characteristics and screening dry-eyes. It alleviates the discomfort and inconvenience encountered during conventional dry-eye diagnosis.
Collapse
|
40
|
Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control. J Ophthalmol 2020; 2020:8067657. [PMID: 32318285 PMCID: PMC7152962 DOI: 10.1155/2020/8067657] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/07/2023] Open
Abstract
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.
Collapse
|
41
|
Abstract
Measurement of tear film breakup time (TBUT) has become a standard diagnostic procedure in the dry eye clinic. Short TBUT-type dry eye is characterized by TBUT of less than 5 seconds and dry eye symptoms such as ocular fatigue or dryness; the importance of this type has recently been gaining prominence. Patients with this condition show no reduction in tear production and no staining of the ocular surface. The severity of symptoms is almost the same as in dry eye in which the ocular surface is stained with rose bengal or fluorescein. In addition to discomfort, patients suffer from decreased vision due to the unstable tear film, which can be attributed to the relative abnormality of the lipid layer, aqueous layer, and/or mucin layer. The diagnosis should be performed carefully on the basis of the patient's symptoms and the TBUT test, because the ocular surface appears normal and remains unstained.
Collapse
Affiliation(s)
- Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| |
Collapse
|