1
|
Wang L, Sun J, Wang X, Lei M, Shi Z, Liu L, Xu C. Visual and quantitative lateral flow immunoassay based on Au@PS SERS tags for multiplex cardiac biomarkers. Talanta 2024; 274:126040. [PMID: 38581853 DOI: 10.1016/j.talanta.2024.126040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 03/27/2024] [Accepted: 04/02/2024] [Indexed: 04/08/2024]
Abstract
Rapid and sensitive detection of multiple biomarkers by lateral flow immunoassay (LFIA) remains challenging for signal amplification for commonly used nanotags. Herein, we report a novel LFIA strip for visual and highly sensitive analysis of two cardiac biomarkers based on functionalized gold nanoparticles @ polystyrene microsphere (Au@PS)microcavity as surface-enhanced Raman scattering (SERS) tags. Antibody-modified Au@PS was designed as a SERS label. The evanescent waves propagating along the surface of the PS microcavity and the localized surface plasmons of the gold nanoparticles were coupled to enhance the light-matter interaction synergistically for Raman signal enhancement. In this strategy, the proposed Au@PS SERS tags-based LFIA was carried out to quantify the content of the heart failure and infarct biomarkers synchronously within 15 min and get the limits of detection of 1 pg/mL and 10 pg/mL for cardiac troponin I (cTnI) and N-terminal natriuretic peptide precursor (NT-proBNP), respectively. The results demonstrated 10-20 folds more sensitivity than that of the standard colloidal gold strip and fluorescent strip for the same biomarkers. This novel quantitative LFIA shows promise as a high-sensitive and visual sensing method for relevant clinical and forensic analysis.
Collapse
Affiliation(s)
- Li Wang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Jianli Sun
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Xiaoxuan Wang
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Milan Lei
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China
| | - Zengliang Shi
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
| | - Lei Liu
- Faculty Electronic Information Engineering, Huaiyin Institute of Technology, Huaiyin, 223003, China.
| | - Chunxiang Xu
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
| |
Collapse
|
2
|
Stoia D, De Sio L, Petronella F, Focsan M. Recent advances towards point-of-care devices for fungal detection: Emphasizing the role of plasmonic nanomaterials in current and future technologies. Biosens Bioelectron 2024; 255:116243. [PMID: 38547645 DOI: 10.1016/j.bios.2024.116243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 03/14/2024] [Accepted: 03/22/2024] [Indexed: 04/15/2024]
Abstract
Fungal infections are a significant global health problem, particularly affecting individuals with weakened immune systems. Moreover, as uncontrolled antibiotic and immunosuppressant use increases continuously, fungal infections have seen a dramatic increase, with some strains developing antibiotic resistance. Traditional approaches to identifying fungal strains often rely on morphological characteristics, thus owning limitations, such as struggles in identifying several strains or distinguishing between fungal strains with similar morphologies. This review explores the multifaceted impact of fungi infections on individuals, healthcare providers, and society, highlighting the often-underestimated economic burden and healthcare implications of these infections. In light of the serious constraints of traditional fungal identification methods, this review discusses the potential of plasmonic nanoparticle-based biosensors for fungal infection identification. These biosensors can enable rapid and precise fungal pathogen detection by exploiting several readout approaches, including various spectroscopic techniques, colorimetric and electrochemical assays, as well as lateral-flow immunoassay methods. Moreover, we report the remarkable impact of plasmonic Lab on a Chip technology and microfluidic devices, as they recently emerged as a class of advanced biosensors. Finally, we provide an overview of smartphone-based Point-of-Care devices and the associated technologies developed for detecting and identifying fungal pathogens.
Collapse
Affiliation(s)
- Daria Stoia
- Biomolecular Physics Department, Faculty of Physics, Babes-Bolyai University, 1 M. Kogalniceanu Street, 400084, Cluj-Napoca, Romania; Nanobiophotonics and Laser Microspectroscopy Centre, Interdisciplinary Research Institute on Bio-Nano-Sciences, Babes-Bolyai University, 42 Treboniu Laurian Street, 400271, Cluj-Napoca, Romania
| | - Luciano De Sio
- Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Corso della Repubblica 79, 04100, Latina, Italy
| | - Francesca Petronella
- National Research Council of Italy, Institute of Crystallography CNR-IC, Area della Ricerca Roma 1 Strada Provinciale 35d, n. 9, 00010, Montelibretti (RM), Italy.
| | - Monica Focsan
- Biomolecular Physics Department, Faculty of Physics, Babes-Bolyai University, 1 M. Kogalniceanu Street, 400084, Cluj-Napoca, Romania; Nanobiophotonics and Laser Microspectroscopy Centre, Interdisciplinary Research Institute on Bio-Nano-Sciences, Babes-Bolyai University, 42 Treboniu Laurian Street, 400271, Cluj-Napoca, Romania.
| |
Collapse
|
3
|
El Aamri M, Baachaoui S, Mohammadi H, Raouafi N, Amine A. Smartphone-based device for rapid and single-step detection of piRNA-651 using anti-DNA:RNA hybrid antibody and enzymatic signal amplification. Anal Chim Acta 2024; 1305:342583. [PMID: 38677845 DOI: 10.1016/j.aca.2024.342583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 04/01/2024] [Accepted: 04/04/2024] [Indexed: 04/29/2024]
Abstract
P-element-induced wimpy testis (PIWI)-interacting RNAs (piRNAs/piRs) are a class of small noncoding RNAs that play a crucial role in regulating various biological processes, including carcinogenesis. One specific piRNA, piR-651, has been reported to be overexpressed in both human blood serum and solid cancer tissues, that can be used a viable biomarker in cancer diagnosis. Early diagnosis of cancer can help reduce the burden of the disease and improve survival rates. In the present work, we report for the first time a smartphone-based colorimetric biosensor for highly sensitive and specific detection of piR-651 thanks to an enzymatic signal amplification, which yielded high colorimetric intensities. Indeed, a heteroduplex DNA:RNA was formed in the presence of piR-651 with the capture DNA probe immobilized on the magnetic beads for easy magnetic separation. Then, a HRP tethered to anti-DNA:RNA (S9.6) was used to reveal the DNA-RNA heteroduplex formed by catalyzing the oxidation of TMB substrate into colorimetric TMBox, which absorbs at 630 nm. The absorbance is positively proportional to the piR-651 concentrations. On the other hand, the colorimetric product of the assay can be photographed with a smartphone camera and analyzed using ImageJ software. Using a smartphone and under optimal conditions, the biosensor responded linearly to the logarithm of piRNA-651 from 8 fM to 100 pM with a detection limit of 2.3 fM and discriminates against other piRNAs. It was also successfully applied to the determination of piRNA-651 levels in spiked human serum.
Collapse
Affiliation(s)
- Maliana El Aamri
- Hassan II University of Casablanca, Faculty of Sciences and Techniques, Laboratory of Process Engineering and Environment, Chemical Analysis and Biosensors Group, P.A 146, Mohammedia, Morocco
| | - Sabrine Baachaoui
- University of Tunis El Manar, Faculty of Science, Chemistry Department, Analytical Chemistry and Electrochemistry Lab (LR99ES15), Sensors and Biosensors Group, Tunis El Manar, 2092, Tunisia
| | - Hasna Mohammadi
- Hassan II University of Casablanca, Faculty of Sciences and Techniques, Laboratory of Process Engineering and Environment, Chemical Analysis and Biosensors Group, P.A 146, Mohammedia, Morocco
| | - Noureddine Raouafi
- University of Tunis El Manar, Faculty of Science, Chemistry Department, Analytical Chemistry and Electrochemistry Lab (LR99ES15), Sensors and Biosensors Group, Tunis El Manar, 2092, Tunisia.
| | - Aziz Amine
- Hassan II University of Casablanca, Faculty of Sciences and Techniques, Laboratory of Process Engineering and Environment, Chemical Analysis and Biosensors Group, P.A 146, Mohammedia, Morocco.
| |
Collapse
|
4
|
Malik S, Singh J, Saini K, Chaudhary V, Umar A, Ibrahim AA, Akbar S, Baskoutas S. Paper-based sensors: affordable, versatile, and emerging analyte detection platforms. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2777-2809. [PMID: 38639474 DOI: 10.1039/d3ay02258g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Paper-based sensors, often referred to as paper-based analytical devices (PADs), stand as a transformative technology in the field of analytical chemistry. They offer an affordable, versatile, and accessible solution for diverse analyte detection. These sensors harness the unique properties of paper substrates to provide a cost-effective and adaptable platform for rapid analyte detection, spanning chemical species, biomolecules, and pathogens. This review highlights the key attributes that make paper-based sensors an attractive choice for analyte detection. PADs demonstrate their versatility by accommodating a wide range of analytes, from ions and gases to proteins, nucleic acids, and more, with customizable designs for specific applications. Their user-friendly operation and minimal infrastructure requirements suit point-of-care diagnostics, environmental monitoring, food safety, and more. This review also explores various fabrication methods such as inkjet printing, wax printing, screen printing, dip coating, and photolithography. Incorporating nanomaterials and biorecognition elements promises even more sophisticated and sensitive applications.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Kajal Saini
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Vivek Chaudhary
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India.
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Ahmed A Ibrahim
- Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices (PCSED), Najran University, Najran-11001, Kingdom of Saudi Arabia.
- STEM Pioneers Training Lab, Najran University, Najran 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus 43210, OH, USA
| | | |
Collapse
|
5
|
Han DH, Lee G, Oh U, Choi Y, Park JK. Evaluation of Fluid Behaviors in a Pushbutton-Activated Microfluidic Device for User-Independent Flow Control. MICROMACHINES 2024; 15:465. [PMID: 38675276 PMCID: PMC11052212 DOI: 10.3390/mi15040465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 03/27/2024] [Accepted: 03/28/2024] [Indexed: 04/28/2024]
Abstract
Although numerous studies have been conducted to realize ideal point-of-care testing (POCT), the development of a user-friendly and user-independent power-free microfluidic platform is still a challenge. Among various methods, the finger-actuation method shows a promising technique that provides a user-friendly and equipment-free way of delivering fluid in a designated manner. However, the design criteria and elaborate evaluation of the fluid behavior of a pushbutton-activated microfluidic device (PAMD) remain a critical bottleneck to be widely adopted in various applications. In this study, we have evaluated the fluid behavior of the PAMD based on various parameters, such as pressing velocity and depth assisted by a press machine. We have further developed a user-friendly and portable pressing block that reduces user variation in fluid behavior based on the evaluation.
Collapse
Affiliation(s)
- Dong Hyun Han
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Gihyun Lee
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Untaek Oh
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Yejin Choi
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
| | - Je-Kyun Park
- Department of Bio and Brain Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea; (D.H.H.); (G.L.); (U.O.); (Y.C.)
- KI for Health Science and Technology, KAIST Institutes (KI), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KI for NanoCentury, KAIST Institutes (KI), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
6
|
Kaewarsa P, Schenkel MS, Rahn KL, Laiwattanapaisal W, Henry CS. Improving design features and air bubble manipulation techniques for a single-step sandwich electrochemical ELISA incorporating commercial electrodes into capillary-flow driven immunoassay devices. Analyst 2024; 149:2034-2044. [PMID: 38407468 PMCID: PMC10962017 DOI: 10.1039/d3an01704d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 02/15/2024] [Indexed: 02/27/2024]
Abstract
Integrating electrochemistry into capillary-flow driven immunoassay devices provides unique opportunities for quantitative point-of-care testing. Although custom electrodes can be inexpensive and are tunable, they require skilled fabrication. Here, we report the incorporation of a commercial electrode into a capillary-flow driven immunoassay (iceCaDI) device for a single end-user step sandwich electrochemical enzyme-linked immunosorbent assay (ELISA). The iceCaDI device is a pump-free portable microfluidic device with an integrated commercial screen-printed electrode and flow driven by capillary action. The iceCaDI device is composed of alternating polyester transparency film and double-sided adhesive film layers that are patterned with a laser cutter. This platform was designed to address known limitations of laminated device fabrication methods and operation. First, we developed a foldable laminated device fabrication using hinges for easy assembly and precise alignment. Second, reagent dispersing was achieved by incorporating a 1 mm wide arrow-shaped notch in the middle of the channel that trapped an air bubble and formed a baffle that facilitated reagent spreading to cover the detection area. Third, small vent holes were added to the top layer of the channels to prevent air bubbles from blocking flow. Finally, we fabricated a CRP immunosensor with a detection range of 0.625 to 10.0 μg mL-1 as a proof-of-concept to demonstrate an automatically driven sandwich electrochemical ELISA using the iceCaDI device. Three concentrations of CRP were successfully measured under flow conditions within 8 min. Our proposed device is a promising approach and a step forward in the development of point-of-care (POC) devices for techniques that traditionally require multiple user steps.
Collapse
Affiliation(s)
- Phuritat Kaewarsa
- Graduate Program in Clinical Biochemistry and Molecular Medicine, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Melissa S Schenkel
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
| | - Kira L Rahn
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
| | - Wanida Laiwattanapaisal
- Biosensors and Bioanalytical Technology for Cell and Innovative Testing Research Unit, Department of Clinical Chemistry, Faculty of Allied Health Sciences, Chulalongkorn University, Bangkok, 10330, Thailand
| | - Charles S Henry
- Department of Chemistry, Colorado State, University, Fort Collins, Colorado, 80526, USA
- Materials and Metallurgy Research Institute, Chulalongkorn University, Bangkok, 10330, Thailand.
| |
Collapse
|
7
|
Link JS, O'Donnell-Sloan J, Curdts S, Geiss BJ, Dandy DS, Henry CS. Multiplexed Capillary-Flow Driven Immunoassay for Respiratory Illnesses. Anal Chem 2024; 96:4111-4119. [PMID: 38417100 DOI: 10.1021/acs.analchem.3c04977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/01/2024]
Abstract
Multiplexed analysis in medical diagnostics is widely accepted as a more thorough and complete method compared to single-analyte detection. While analytical methods like polymerase chain reaction and enzyme-linked immunosorbent assay (ELISA) exist for multiplexed detection of biomarkers, they remain time-consuming and expensive. Lateral flow assays (LFAs) are an attractive option for point-of-care testing, and examples of multiplexed LFAs exist. However, these devices are limited by spatial resolution of test lines, large sample volume requirements, cross-reactivity, and poor sensitivity. Recent work has developed capillary-flow microfluidic ELISA platforms as a more sensitive alternative to LFAs; however, multiplexed detection on these types of devices has yet to be demonstrated. In the aftermath of the initial SARS-CoV-2 pandemic, the need for rapid, sensitive point-of-care devices has become ever clearer. Moving forward, devices that can distinguish between diseases with similar presenting symptoms would be the ideal home diagnostic. Here, the first example of a multiplexed capillary-flow immunoassay device for the simultaneous detection of multiple biomarkers is reported. From a single sample addition step, the reagents and washing steps required for two simultaneous ELISAs are delivered to spatially separated test strips. Visual results can be obtained in <15 min, and images captured with a smartphone can be analyzed for quantitative data. This device was used to distinguish between and quantify H1N1 hemagglutinin (HA) and SARS-CoV-2 nucleocapsid protein (N-protein). Using this device, analytical detection limits of 840 and 133 pg/mL were obtained for hemagglutinin and nucleocapsid protein, respectively. The presence of one target in the device did not increase the signal on the other test line, indicating no cross-reactivity between the assays. Additionally, simultaneous detection of both N-protein and HA was performed as well as simultaneous detection of N-protein and human C-reactive protein (CRP). Elevated levels of CRP in a patient infected with SARS-CoV-2 have been shown to correlate with more severe outcomes and a greater risk of death as well. To further expand on the simultaneous detection of two biomarkers, CRP and N-protein were detected simultaneously, and the presence of SARS-CoV-2 N-protein did not interfere with the detection of CRP when both targets were present in the sample.
Collapse
Affiliation(s)
- Jeremy S Link
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - John O'Donnell-Sloan
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
| | - Sierra Curdts
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Brian J Geiss
- Department of Microbiology, Immunology and Pathology, Colorado State University, Fort Collins, Colorado 80523, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - David S Dandy
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
| | - Charles S Henry
- Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523, United States
- Department of Chemical and Biological Engineering, Colorado State University, Fort Collins, Colorado 80523-1019, United States
- School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado 80523, United States
- Metalluragy and Materials Research Institute, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
8
|
Argoubi W, Algethami FK, Raouafi N. Enhanced sensitivity in electrochemical detection of ochratoxin A within food samples using ferrocene- and aptamer-tethered gold nanoparticles on disposable electrodes. RSC Adv 2024; 14:8007-8015. [PMID: 38454949 PMCID: PMC10918640 DOI: 10.1039/d3ra08567h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/01/2024] [Indexed: 03/09/2024] Open
Abstract
Ensuring food security is crucial for public health, and the presence of mycotoxins, produced by fungi in improperly stored processed or unprocessed food, poses a significant threat. This research introduces a novel approach - a disposable aptasensing platform designed for the detection of ochratoxin A (OTA). The platform employs gold-nanostructured screen-printed carbon electrodes functionalized with a ferrocene derivative, serving as an integrated faradaic transducing system, and an anti-OTA aptamer as a bioreceptor site. Detection relies on the ferrocene electrochemical signal changes induced by the aptamer folding in the presence of the target molecule. Remarkably sensitive, the platform detects OTA within the range of 0.5 to 70 ng mL-1 and a detection limit of 11 pg mL-1. This limit is approximately 200 times below the levels stipulated by the European Commission for agricultural commodities. Notably, the sensing device exhibits efficacy in detecting OTA in complex media, such as roasted coffee beans and wine, without the need for sample pretreatment, yielding accurate recoveries. Furthermore, while label-free electrochemical aptasensors have proliferated, this study addresses a gap in understanding the binding mechanisms of some aptasensors. To enhance the experimental findings, a theoretical study was conducted to underscore the specificity of the anti-OTA aptamer as a donor for OTA detection. The molecular docking technique was employed to unveil the key binding region of the aptamer, providing valuable insights into the aptasensor specificity.
Collapse
Affiliation(s)
- Wicem Argoubi
- Sensors and Biosensors Group, ACE-Lab (LR99ES15), Faculty of Science, University of Tunis El Manar 2092 Tunis El Manar Tunisia
| | - Faisal K Algethami
- Department of Chemistry, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU) P.O. Box 90950 Riyadh 11623 Saudi Arabia
| | - Noureddine Raouafi
- Sensors and Biosensors Group, ACE-Lab (LR99ES15), Faculty of Science, University of Tunis El Manar 2092 Tunis El Manar Tunisia
| |
Collapse
|
9
|
Ke CH, Du MY, Hsieh WJ, Lin CC, Ting JM, Chiou MT, Lin CN. Implementation of point-of-care platforms for rapid detection of porcine circovirus type 2. J Vet Sci 2024; 25:e28. [PMID: 38568829 PMCID: PMC10990909 DOI: 10.4142/jvs.23323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/12/2024] [Accepted: 02/23/2024] [Indexed: 04/05/2024] Open
Abstract
BACKGROUND Porcine circovirus type 2 (PCV2) infection is ubiquitous around the world. Diagnosis of the porcine circovirus-associated disease requires clinic-pathological elements together with the quantification of viral loads. Furthermore, given pig farms in regions lacking access to sufficient laboratory equipment, developing diagnostic devices with high accuracy, accessibility, and affordability is a necessity. OBJECTIVES This study aims to investigate two newly developed diagnostic tools that may satisfy these criteria. METHODS We collected 250 specimens, including 170 PCV2-positive and 80 PCV2-negative samples. The standard diagnosis and cycle threshold (Ct) values were determined by quantitative polymerase chain reaction (qPCR). Then, two point-of-care (POC) diagnostic platforms, convective polymerase chain reaction (cPCR, qualitative assay: positive or negative results are shown) and EZtargex (quantitative assay: Ct values are shown), were examined and analyzed. RESULTS The sensitivity and specificity of cPCR were 88.23% and 100%, respectively; the sensitivity and specificity of EZtargex were 87.65% and 100%, respectively. These assays also showed excellent concordance compared with the qPCR assay (κ = 0.828 for cPCR and κ = 0.820 for EZtargex). The statistical analysis showed a great diagnostic power of the EZtargex assay to discriminate between samples with different levels of positivity. CONCLUSIONS The two point-of-care diagnostic platforms are accurate, rapid, convenient and require little training for PCV2 diagnosis. These POC platforms can discriminate viral loads to predict the clinical status of the animals. The current study provided evidence that these diagnostics were applicable with high sensitivity and specificity in the diagnosis of PCV2 infection in the field.
Collapse
Affiliation(s)
- Chiao-Hsu Ke
- Sustainable Swine Research Center, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
- Animal Disease Diagnostic Center, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
| | - Mao-Yuan Du
- Department of Veterinary Medicine, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
| | - Wang-Ju Hsieh
- Schweitzer Biotech Company Ltd., Taipei 11493, Taiwan
| | | | | | - Ming-Tang Chiou
- Sustainable Swine Research Center, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
- Animal Disease Diagnostic Center, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
- Department of Veterinary Medicine, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan.
| | - Chao-Nan Lin
- Sustainable Swine Research Center, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
- Animal Disease Diagnostic Center, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan
- Department of Veterinary Medicine, College of Veterinary Medicine, National Pingtung University of Science and Technology, Pingtung 91201, Taiwan.
| |
Collapse
|
10
|
Saeed M, Saddique Z, Mujahid A, Afzal A. Discerning biomimetic nanozyme electrodes based on g-C 3N 4 nanosheets and molecularly imprinted polythiophene nanofibers for detecting creatinine in microliter droplets of human saliva. Biosens Bioelectron 2024; 247:115899. [PMID: 38091897 DOI: 10.1016/j.bios.2023.115899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 11/26/2023] [Accepted: 11/27/2023] [Indexed: 01/02/2024]
Abstract
The growing risk of death associated with kidney dysfunction underlines the requirement for a cost-effective and precise point-of-care (POC) diagnostic tool to identify chronic kidney disease (CKD) at an early stage. This work reports the development of a non-invasive POC diagnostic based on cost-efficient, disposable electrodes and in situ-designed biomimetic nanozymes. The nanozymes are composed of graphitic carbon nitride nanosheets (gCN) and creatinine-imprinted polythiophene nanofibers (miPTh). Microscopic analyses reveal porous nanofibrous surface morphology of biomimetic miPTh/gCN nanozymes. Bulk imprinting and the inclusion of conductive gCN nanosheets drastically reduced the charge transfer resistance and improved the electron exchange kinetics at the nanozyme-electrolyte interface. The electrochemical oxidation of creatinine is studied via cyclic voltammetry (CV), and differential pulse voltammetry (DPV), which exhibit excellent creatinine recognition ability of biomimetic miPTh/gCN nanozyme sensors compared to pristine polymeric or non-imprinted nanozymes. The sensor reveals linear response toward 200-1000 nmol L-1 creatinine, high sensitivity (4.27 μA cm-2 nmol-1 L), sub-nanomolar detection limit (340 pmol L-1), and excellent selectivity over common salivary analytes. To corroborate its real-world utility, the miPTh/gCN nanozyme sensor shows an impressive 94.8% recovery of spiked creatinine concentrations in microliter droplets of human saliva samples. This disposable sensor reveals great potential in the realm of reliable and efficient non-invasive POC diagnostics for healthcare delivery.
Collapse
Affiliation(s)
- Maleeha Saeed
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan
| | - Zohaib Saddique
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan
| | - Adnan Mujahid
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan
| | - Adeel Afzal
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore, 54590, Pakistan.
| |
Collapse
|
11
|
Knudsen C, Belfakir SB, Degnegaard P, Jürgensen JA, Haack AM, Friis RUW, Dam SH, Laustsen AH, Ross GMS. Multiplex lateral flow assay development for snake venom detection in biological matrices. Sci Rep 2024; 14:2567. [PMID: 38296989 PMCID: PMC10831076 DOI: 10.1038/s41598-024-51971-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Accepted: 01/11/2024] [Indexed: 02/02/2024] Open
Abstract
Bothrops and Lachesis are two of Brazil's medically most relevant snake genera, causing tens of thousands of bites annually. Fortunately, Brazil has good accessibility to high-quality antivenoms at the genus and inter-genus level, enabling the treatment of many of these envenomings. However, the optimal use of these treatments requires that the snake species responsible for the bite is determined. Currently, physicians use a syndromic approach to diagnose snakebite, which can be difficult for medical personnel with limited training in clinical snakebite management. In this work, we have developed a novel monoclonal antibody-based multiplex lateral flow assay for differentiating Bothrops and Lachesis venoms within 15 min. The test can be read by the naked eye or (semi)-quantitatively by a smartphone supported by a 3D-printed attachment for controlling lighting conditions. The LFA can detect Bothrops and Lachesis venoms in spiked plasma and urine matrices at concentrations spanning six orders of magnitude. The LFA has detection limits of 10-50 ng/mL in spiked plasma and urine, and 50-500 ng/mL in spiked sera, for B. atrox and L. muta venoms. This test could potentially support medical personnel in correctly diagnosing snakebite envenomings at the point-of-care in Brazil, which may help improve patient outcomes and save lives.
Collapse
Affiliation(s)
- Cecilie Knudsen
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark.
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark.
| | - Selma B Belfakir
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark.
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark.
| | | | - Jonas A Jürgensen
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | - Aleksander M Haack
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | - Rasmus U W Friis
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | - Søren H Dam
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | - Andreas H Laustsen
- VenomAid Diagnostics, 2800, Kongens Lyngby, Denmark
- Department of Biotechnology and Biomedicine, Technical University of Denmark, 2800, Kongens Lyngby, Denmark
| | | |
Collapse
|
12
|
Klebes A, Ates HC, Verboket RD, Urban GA, von Stetten F, Dincer C, Früh SM. Emerging multianalyte biosensors for the simultaneous detection of protein and nucleic acid biomarkers. Biosens Bioelectron 2024; 244:115800. [PMID: 37925943 DOI: 10.1016/j.bios.2023.115800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/17/2023] [Accepted: 10/27/2023] [Indexed: 11/07/2023]
Abstract
Traditionally, biosensors are designed to detect one specific analyte. Nevertheless, disease progression is regulated in a highly interactive way by different classes of biomolecules like proteins and nucleic acids. Therefore, a more comprehensive analysis of biomarkers from a single sample is of utmost importance to further improve both, the accuracy of diagnosis as well as the therapeutic success. This review summarizes fundamentals like biorecognition and sensing strategies for the simultaneous detection of proteins and nucleic acids and discusses challenges related to multianalyte biosensor development. We present an overview of the current state of biosensors for the combined detection of protein and nucleic acid biomarkers associated with widespread diseases, among them cancer and infectious diseases. Furthermore, we outline the multianalyte analysis in the rapidly evolving field of single-cell multiomics, to stress its significance for the future discovery and validation of biomarkers. Finally, we provide a critical perspective on the performance and translation potential of multianalyte biosensors for medical diagnostics.
Collapse
Affiliation(s)
- Anna Klebes
- Hahn-Schickard, 79110, Freiburg, Germany; University of Freiburg, IMTEK - Department of Microsystems Engineering, Laboratory for MEMS Applications, 79110, Freiburg, Germany
| | - H Ceren Ates
- University of Freiburg, IMTEK - Department of Microsystems Engineering, Disposable Microsystems Group, 79110, Freiburg, Germany; University of Freiburg, FIT Freiburg Centre for Interactive Materials and Bioinspired Technology, 79110, Freiburg, Germany
| | - René D Verboket
- Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Frankfurt, Johann Wolfgang Goethe University, 60590, Frankfurt am Main, Germany
| | - Gerald A Urban
- University of Freiburg, IMTEK - Department of Microsystems Engineering, Laboratory for Sensors, 79110, Freiburg, Germany; University of Freiburg, Freiburg Materials Research Centre - FMF, 79104, Freiburg, Germany
| | - Felix von Stetten
- Hahn-Schickard, 79110, Freiburg, Germany; University of Freiburg, IMTEK - Department of Microsystems Engineering, Laboratory for MEMS Applications, 79110, Freiburg, Germany
| | - Can Dincer
- University of Freiburg, IMTEK - Department of Microsystems Engineering, Disposable Microsystems Group, 79110, Freiburg, Germany; University of Freiburg, FIT Freiburg Centre for Interactive Materials and Bioinspired Technology, 79110, Freiburg, Germany
| | - Susanna M Früh
- Hahn-Schickard, 79110, Freiburg, Germany; University of Freiburg, IMTEK - Department of Microsystems Engineering, Laboratory for MEMS Applications, 79110, Freiburg, Germany
| |
Collapse
|
13
|
Lee SM, Nai YH, Doeven EH, Balakrishnan HK, Yuan D, Guijt RM. Abridged solid-phase extraction with alkaline Poly(ethylene) glycol lysis (ASAP) for direct DNA amplification. Talanta 2024; 266:125006. [PMID: 37572478 DOI: 10.1016/j.talanta.2023.125006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 07/23/2023] [Accepted: 07/28/2023] [Indexed: 08/14/2023]
Abstract
Complexity of sample preparation decelerate the development of sample-in-answer-out devices for point-of-need nucleic acid amplification testing. Here, we present the consolidation of alkaline poly(ethylene) glycol-based lysis and solid-phase extraction for rapid and simple sample preparation compatible with direct on-bead amplification. Simultaneous cell lysis and binding of DNA were achieved using an optimised reagent comprising 15% PEG8000, 0.5 M NaCl, and 3.5 mM KOH. This was combined with direct, on-bead amplification using 1.5 μg beads per 20 μL PCR reaction mix. The novel single reagent, 5-min method improved the detection limit by 10 and 100-fold compared with commercial DNA extraction kits and the original alkaline PEG lysis method, respectively. The sensitivity can be further enhanced by one amplification cycle with an ethanol wash or by extending the incubation to 10 min before collecting the magnetic particles. Both methods successfully detected a single copy of Escherichia coli DNA. In biological fluids (saliva, sweat, and urine), the 5-min method was delayed by about one cycle compared to the 15-min method. The proposed methods are attractive for incorporation in the workflow for point-of-need testing of biological samples by providing a practical and chemical method for simple alternative DNA sample preparation.
Collapse
Affiliation(s)
- Soo Min Lee
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia
| | - Yi H Nai
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia
| | - Egan H Doeven
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia; Deakin University, School of Life and Environmental Sciences, Waurn Ponds, VIC 3216, Australia
| | - Hari Kalathil Balakrishnan
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia; Department of Chemical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Dan Yuan
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia; School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072, Australia.
| | - Rosanne M Guijt
- Deakin University, Centre for Rural and Regional Futures (CeRRF), Waurn Ponds, VIC 3216, Australia.
| |
Collapse
|
14
|
Oldak L, Lukaszewski Z, Leśniewska A, Goławski K, Laudański P, Gorodkiewicz E. Development of an SPRi Test for the Quantitative Detection of Cadherin 12 in Human Plasma and Peritoneal Fluid. Int J Mol Sci 2023; 24:16894. [PMID: 38069216 PMCID: PMC10706750 DOI: 10.3390/ijms242316894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 11/24/2023] [Accepted: 11/27/2023] [Indexed: 12/18/2023] Open
Abstract
A new method for the determination of cadherin 12 (CDH12)-an adhesive protein that has a significant impact on the development, growth, and movement of cancer cells-was developed and validated. The method is based on a biosensor using surface plasmon resonance imaging (SPRi) detection. A quartz crystal microbalance was used to analyze the characteristics of the formation of successive layers of the biosensor, from the linker monolayer to the final capture of CDH12 from solution. The association equilibrium constant (KA = 1.66 × 1011 dm3 mol-1) and the dissociation equilibrium constant (KD = 7.52 × 10-12 mol dm-3) of the anti-CDH12 antibody-CDH12 protein complex were determined. The determined analytical parameters, namely the values determining the accuracy, precision, and repeatability of the method, do not exceed the permissible 20% deviations specified by the aforementioned institutions. The proposed method is also selective with respect to possible potential interferents, occurring in up to 100-fold excess concentration relative to the CDH12 concentration. The determined Limit of Quantification (LOQ = 4.92 pg mL-1) indicates the possibility of performing quantitative analysis in human plasma or peritoneal fluid without the need to concentrate the samples; however, particular attention should be paid to their storage conditions, as the analyte does not exhibit high stability. The Passing-Bablok regression model revealed good agreement between the reference method and the SPRi biosensor, with ρSpearman values of 0.961 and 0.925.
Collapse
Affiliation(s)
- Lukasz Oldak
- Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland (E.G.)
| | - Zenon Lukaszewski
- Faculty of Chemical Technology, Poznan University of Technology, pl. Sklodowskiej-Curie 5, 60-965 Poznan, Poland
| | - Anna Leśniewska
- Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland (E.G.)
| | - Ksawery Goławski
- 1st Department of Obstetrics and Gynecology, Medical University of Warsaw, 02-091 Warsaw, Poland
| | - Piotr Laudański
- Department of Obstetrics, Gynecology and Gynecological Oncology, Medical University of Warsaw, 02-091 Warsaw, Poland
- OVIklinika Infertility Center, 01-377 Warsaw, Poland
- Women’s Health Research Institute, Calisia University, 62-800 Kalisz, Poland
| | - Ewa Gorodkiewicz
- Bioanalysis Laboratory, Faculty of Chemistry, University of Bialystok, Ciolkowskiego 1K, 15-245 Bialystok, Poland (E.G.)
| |
Collapse
|
15
|
Lee JY, Lee S, Lee H, Tran TTP, Kim BC, Rhee WJ. In Situ Simultaneous Detection of Surface Protein and microRNA in Clustered Extracellular Vesicles from Cancer Cell Lines Using Flow Cytometry. ACS Biomater Sci Eng 2023; 9:6369-6378. [PMID: 37905510 DOI: 10.1021/acsbiomaterials.3c01459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Extracellular vesicles (EVs) are becoming increasingly important in liquid biopsy for cancer because they contain multiple biomarkers, including proteins and RNAs, and circulate throughout the body. Cancer cell-derived EVs are highly heterogeneous, and multiplexed biomarker detection techniques are required to improve the accuracy of diagnosis. In addition, in situ EV biomarker detection increases the efficiency of the detection process because EVs are difficult to handle. In this study, in situ simultaneous detection of EV surface proteins, programmed cell death-ligand 1 (PD-L1), and internal miRNA-21 (miR-21) analyzed by conventional flow cytometry was developed for a breast cancer liquid biopsy. However, the majority of EVs were not recognized by flow cytometry for biomarker detection because the size of EVs was below the detectable size range of the flow cytometer. To solve this problem, the formation of EV clusters was induced by 1,2-distearoyl-sn-glycero-3-phosphoethanolamine (DSPE)-polyethylene glycol-DSPE during biomarker detection. Consequently, both PD-L1 and miR-21 detection signals from cancer cell-derived EVs were drastically increased, making them distinguishable from normal cell-derived EVs. The in situ simultaneous cancer biomarker detection from EV clusters analyzed by flow cytometry contributes to an increase in the sensitivity and accuracy of the EV-based liquid biopsy for cancer.
Collapse
Affiliation(s)
- Ji Yoon Lee
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Soye Lee
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Haneul Lee
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Tham Truong Phuong Tran
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
- Department of Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Byoung Choul Kim
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
- Department of Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
| | - Won Jong Rhee
- Department of Bioengineering and Nano-Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
- Division of Bioengineering, Incheon National University, Incheon 22012, Republic of Korea
- Research Center for Bio Materials & Process Development, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Republic of Korea
| |
Collapse
|
16
|
Di Filippo D, Sunstrum FN, Khan JU, Welsh AW. Non-Invasive Glucose Sensing Technologies and Products: A Comprehensive Review for Researchers and Clinicians. SENSORS (BASEL, SWITZERLAND) 2023; 23:9130. [PMID: 38005523 PMCID: PMC10674292 DOI: 10.3390/s23229130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 11/01/2023] [Accepted: 11/08/2023] [Indexed: 11/26/2023]
Abstract
Diabetes Mellitus incidence and its negative outcomes have dramatically increased worldwide and are expected to further increase in the future due to a combination of environmental and social factors. Several methods of measuring glucose concentration in various body compartments have been described in the literature over the years. Continuous advances in technology open the road to novel measuring methods and innovative measurement sites. The aim of this comprehensive review is to report all the methods and products for non-invasive glucose measurement described in the literature over the past five years that have been tested on both human subjects/samples and tissue models. A literature review was performed in the MDPI database, with 243 articles reviewed and 124 included in a narrative summary. Different comparisons of techniques focused on the mechanism of action, measurement site, and machine learning application, outlining the main advantages and disadvantages described/expected so far. This review represents a comprehensive guide for clinicians and industrial designers to sum the most recent results in non-invasive glucose sensing techniques' research and production to aid the progress in this promising field.
Collapse
Affiliation(s)
- Daria Di Filippo
- Discipline of Women’s Health, School of Clinical Medicine, Faculty of Medicine, University of New South Wales, Sydney, NSW 2052, Australia;
| | - Frédérique N. Sunstrum
- Product Design, School of Design, Faculty of Design, Architecture and Built Environment, University of Technology Sydney, Sydney, NSW 2007, Australia;
| | - Jawairia U. Khan
- Institute for Biomedical Materials and Devices, School of Mathematical and Physical Sciences, Faculty of Science, University of Technology Sydney, Sydney, NSW 2007, Australia;
| | - Alec W. Welsh
- Discipline of Women’s Health, School of Clinical Medicine, Faculty of Medicine, University of New South Wales, Sydney, NSW 2052, Australia;
- Department of Maternal-Fetal Medicine, Royal Hospital for Women, Randwick, NSW 2031, Australia
| |
Collapse
|
17
|
Lee SM, Balakrishnan HK, Doeven EH, Yuan D, Guijt RM. Chemical Trends in Sample Preparation for Nucleic Acid Amplification Testing (NAAT): A Review. BIOSENSORS 2023; 13:980. [PMID: 37998155 PMCID: PMC10669371 DOI: 10.3390/bios13110980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/02/2023] [Accepted: 11/07/2023] [Indexed: 11/25/2023]
Abstract
Nucleic acid amplification testing facilitates the detection of disease through specific genomic sequences and is attractive for point-of-need testing (PONT); in particular, the early detection of microorganisms can alert early response systems to protect the public and ecosystems from widespread outbreaks of biological threats, including infectious diseases. Prior to nucleic acid amplification and detection, extensive sample preparation techniques are required to free nucleic acids and extract them from the sample matrix. Sample preparation is critical to maximize the sensitivity and reliability of testing. As the enzymatic amplification reactions can be sensitive to inhibitors from the sample, as well as from chemicals used for lysis and extraction, avoiding inhibition is a significant challenge, particularly when minimising liquid handling steps is also desirable for the translation of the assay to a portable format for PONT. The reagents used in sample preparation for nucleic acid testing, covering lysis and NA extraction (binding, washing, and elution), are reviewed with a focus on their suitability for use in PONT.
Collapse
Affiliation(s)
- Soo Min Lee
- Centre for Regional and Rural Futures (CeRRF), Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia
| | - Hari Kalathil Balakrishnan
- Department of Chemical Engineering, Khalifa University, Abu Dhabi P.O. Box 127788, United Arab Emirates;
| | - Egan H. Doeven
- School of Life and Environmental Sciences, Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia;
| | - Dan Yuan
- School of Mechanical and Mining Engineering, The University of Queensland, Brisbane, QLD 4072, Australia;
| | - Rosanne M. Guijt
- Centre for Regional and Rural Futures (CeRRF), Deakin University, Locked Bag 20000, Geelong, VIC 3220, Australia
| |
Collapse
|
18
|
Rodriguez A, Alonso-Morales RA, Lassala A, Rangel P L, Ramírez-Andoney V, Gutierrez CG. Development and validation of a pentaplex assay for the identification of antibodies against common viral diseases in cattle. Access Microbiol 2023; 5:000511.v3. [PMID: 37970075 PMCID: PMC10634487 DOI: 10.1099/acmi.0.000511.v3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Accepted: 09/17/2023] [Indexed: 11/17/2023] Open
Abstract
Animal welfare and economic implications of infectious diseases in cattle demand an efficient surveillance as the foundation for control and eradication programmes. Bovine respiratory syncytial virus (BRSV), Parainfluenza virus type 3 (PI3V), Bovine herpes virus-1 (BoHV-1), Bovine viral diarrhoea virus (BVDV), and Enzootic bovine leukosis virus (EBLV) cause common and often underdiagnosed diseases in cattle that are endemic in most countries [1]. A hallmark of individual exposure to a viral pathogen is the presence of antibodies directed towards that virus. The aim of this study was to develop and validate a pentaplex assay to simultaneously detect and quantify antibodies against BRSV, PI3V, BoHV-1, BVDV and EBLV in serum, as an efficient tool to yield epidemiological data. Monoplex assays were initially developed using either complete BRSV or BoHV-1 viral lysates, or recombinant proteins for BVDV, EBLV or PI3V as capture antigens. In addition, 125 serum samples from unvaccinated cattle, which were classified as positive or negative for each of the viruses by commercial ELISA kits, were used for validation. Conditions established for the Luminex monoplex assays were adopted for the pentaplex assay. The accuracy, determined by the area under the ROC curve, was greater than 0.97, and assay diagnostic sensitivities and specificities were over 95 and 90%, respectively, for all antigens. Intra (r) and interassay (R) coefficients of variation were under 10 and 20 %, respectively. Selectivity towards target viruses was shown by binding inhibition assays where unbound viruses reduced fluorescence intensities. Diagnostic agreement for samples analysed simultaneously in the monoplex and multiplex assays was almost perfect. In conclusion, a highly sensitive pentaplex assay was validated for the simultaneous identification of antibodies directed against BVDV, BoHV-1, PI3V, BRSV and EBLV in serum. The developed pentaplex assay complies with performance characteristics established by international guidelines for diagnostic tests and may be used as a tool for the implementation of epidemiological surveillance.
Collapse
Affiliation(s)
- Ana Rodriguez
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| | - Rogelio A. Alonso-Morales
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| | - Arantzatzu Lassala
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| | - Lucia Rangel P
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| | - Vianey Ramírez-Andoney
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| | - Carlos G. Gutierrez
- Facultad de Medicina Veterinaria y Zootecnia, Universidad Nacional Autónoma de México, Cd. México, Mexico
| |
Collapse
|
19
|
Deng B, Xue J. HIV infection detection using CRISPR/Cas systems: Present and future prospects. Comput Struct Biotechnol J 2023; 21:4409-4423. [PMID: 37711183 PMCID: PMC10498128 DOI: 10.1016/j.csbj.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 08/30/2023] [Accepted: 09/05/2023] [Indexed: 09/16/2023] Open
Abstract
Human immunodeficiency virus (HIV) infection poses substantial medical risks to global public health. An essential strategy to combat the HIV epidemic is timely and effective virus testing. CRISPR-based assays combine the highly compatible CRISPR system with different elements, yielding portability, digitization capabilities, low economic burden and low operational thresholds. The application of CRISPR-based assays has demonstrated rapid, accurate, and accessible means of pathogen testing, suggesting great potential as point-of-care (POC) assays. This review outlines the different types of CRISPR/Cas systems based on Cas proteins and their applications for the detection of HIV. Additionally, we also offer an overview of future perspectives on CRISPR-based methods for HIV detection, including advances in nucleic acid amplification-free testing, improved personal testing, and refined testing for HIV genotypes and drug-resistant strains.
Collapse
Affiliation(s)
- Bingpeng Deng
- Beijing Key Laboratory for Animal Models of Emerging and Re-Emerging Infectious Diseases, Institute of Laboratory Animal Science, Chinese Academy of Medical Sciences, Beijing 100021, China
- NHC Key Laboratory of Human Disease Comparative Medicine, Comparative Medicine Center, Peking Union Medical College, Beijing 100021, China
| | - Jing Xue
- Beijing Key Laboratory for Animal Models of Emerging and Re-Emerging Infectious Diseases, Institute of Laboratory Animal Science, Chinese Academy of Medical Sciences, Beijing 100021, China
- NHC Key Laboratory of Human Disease Comparative Medicine, Comparative Medicine Center, Peking Union Medical College, Beijing 100021, China
- Center for AIDS Research, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
| |
Collapse
|
20
|
Ochwo S, Perez AM, Pérez Aguirreburualde MS. Beyond accuracy: leveraging ASSURED criteria for field evaluation of point-of-care tests for food animal diseases. Front Vet Sci 2023; 10:1239111. [PMID: 37720479 PMCID: PMC10500061 DOI: 10.3389/fvets.2023.1239111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Accepted: 08/18/2023] [Indexed: 09/19/2023] Open
Abstract
The growing availability of point-of-care tests (POCTs) for food-animal diseases offers opportunities for timely diagnosis, facilitating the efficient implementation of control measures. However, field assessment of new POCTs are yet to be standardized. This paper discusses the opportunity of expanding the current approach for the evaluation and validation of POCTs in food animal disease diagnosis, highlighting the limitations of traditional practice that primarily relies on estimating diagnostic accuracy (sensitivity and specificity). Here, the use of a protocol referred to as FIT-REASSURED, a modified framework combining the ASSURED and REASSURED criteria, is proposed to comprehensively assess POCTs. FIT-REASSURED encompasses key criteria such as fitness for purpose, real-time connectivity, ease of specimen collection, affordability, sensitivity, specificity, user-friendliness, rapidity and robustness, equipment-free operation, and deliverability. By incorporating these attributes, FIT-REASSURED provides a customizable approach to assess the accuracy, affordability, and utility of POCTs. Through collaborative efforts among stakeholders, the implementation of a standardized scorecard based on these FIT-REASSURED criteria can improve the reliability and practicality of POCTs in food-animal health.
Collapse
Affiliation(s)
- Sylvester Ochwo
- Center for Animal Health and Food Safety, College of Veterinary Medicine, University of Minnesota, Saint Paul, MN, United States
| | | | | |
Collapse
|
21
|
Ouedraogo B, Baachaoui S, Tall A, Tapsoba I, Raouafi N. Laser-induced graphene electrodes on polyimide membranes modified with gold nanoparticles for the simultaneous detection of dopamine and uric acid in human serum. Mikrochim Acta 2023; 190:316. [PMID: 37480385 DOI: 10.1007/s00604-023-05909-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Accepted: 07/09/2023] [Indexed: 07/24/2023]
Abstract
The level control of biological active molecules in human body fluids is important for the surveillance of several human diseases. Dopamine (DA) and uric acid (UA) are two important biomarkers of neurological and bone diseases, respectively. Design of sensitive and cost-effective sensors for their detection is an effervescent research field. We report on the straightforward design of laser-induced graphene electrodes (LIGEs) from the laser ablation of a polyimide substrate and their modification by electrochemical deposition of gold nanoparticles (AuNPs/LIGE) and their uses as chemosensors. Electrochemical investigations showed that the presence of gold nanoclusters onto the electrode surface improved the electrochemical surface area (ECSA) and the heterogenous electron transfer (HET) rate. Furthermore, the AuNPs/LIGEs can be used to detect simultaneously low concentrations of DA and UA in presence of ascorbic acid (AA) as an potentially interfering substance at redox potentials of 300 mV, 230 mV and 450 mV and 91 mV, respectively, compared with the Ag/AgCl (3 M KCl) reference electrode in cyclic voltametric. The method displayed linear ranges varying from 2 to 20 μM and 5 to 50 μM, led to limits of detection of 0.37 μM and 0.71 μM for DA and UA, respectively. The AuNPs/LIGE was applied to simultaneously detect both analytes in scarcely diluted human serum with good recoveries. The data show that the recovery percentages ranged from 94% ± 2.1 to 102 % ± 0.5 and from 94% ±0.3 to 112% ± 1.4 for dopamine and uric acid, respectively. Thus, the AuNPs/LIGEs are promising candidates for the detection of other biologically active molecules such as drugs, pesticides, and metabolites.
Collapse
Affiliation(s)
- Bibata Ouedraogo
- Université Joseph KI-ZERBO, UFR-SEA, Laboratoire de Chimie Analytique, Environnementale et Biorganique (LCAEBiO), 03 BP 7021, Ouagadougou 03, Burkina Faso
| | - Sabrine Baachaoui
- Université de Tunis El Manar, Faculté des Sciences de Tunis, Laboratoire de Chimie Analytique et Electrochimie (LR99ES15), Sensors and Biosensors Group, 2092, Tunis, El Manar, Tunisia
| | - Amidou Tall
- Université Joseph KI-ZERBO, UFR-SEA, Laboratoire de Chimie Analytique, Environnementale et Biorganique (LCAEBiO), 03 BP 7021, Ouagadougou 03, Burkina Faso
- Laboratoire de Sciences et Technologies (LaST), Université Thomas SANKARA, 12 BP 417, Ouagadougou, Burkina Faso
| | - Issa Tapsoba
- Université Joseph KI-ZERBO, UFR-SEA, Laboratoire de Chimie Analytique, Environnementale et Biorganique (LCAEBiO), 03 BP 7021, Ouagadougou 03, Burkina Faso
| | - Noureddine Raouafi
- Université de Tunis El Manar, Faculté des Sciences de Tunis, Laboratoire de Chimie Analytique et Electrochimie (LR99ES15), Sensors and Biosensors Group, 2092, Tunis, El Manar, Tunisia.
| |
Collapse
|
22
|
Dorta-Gorrín A, Navas-Méndez J, Gozalo-Margüello M, Miralles L, García-Hevia L. Detection of SARS-CoV-2 Based on Nucleic Acid Amplification Tests (NAATs) and Its Integration into Nanomedicine and Microfluidic Devices as Point-of-Care Testing (POCT). Int J Mol Sci 2023; 24:10233. [PMID: 37373381 DOI: 10.3390/ijms241210233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/10/2023] [Accepted: 06/14/2023] [Indexed: 06/29/2023] Open
Abstract
The coronavirus SARS-CoV-2 has highlighted the criticality of an accurate and rapid diagnosis in order to contain the spread of the virus. Knowledge of the viral structure and its genome is essential for diagnosis development. The virus is still quickly evolving and the global scenario could easily change. Thus, a greater range of diagnostic options is essential to face this threat to public health. In response to the global demand, there has been a rapid advancement in the understanding of current diagnostic methods. In fact, innovative approaches have emerged, leveraging the benefits of nanomedicine and microfluidic technologies. Although this development has been incredibly fast, several key areas require further investigation and optimization, such as sample collection and preparation, assay optimization and sensitivity, cost effectiveness, scalability device miniaturization, and portability and integration with smartphones. Addressing these gaps in the knowledge and these technological challenges will contribute to the development of reliable, sensitive, and user-friendly NAAT-based POCTs for the diagnosis of SARS-CoV-2 and other infectious diseases, facilitating rapid and effective patient management. This review aims to provide an overview of current SARS-CoV-2 detection methods based on nucleic acid detection tests (NAATs). Additionally, it explores promising approaches that combine nanomedicine and microfluidic devices with high sensitivity and relatively fast 'time to answer' for integration into point-of-care testing (POCT).
Collapse
Affiliation(s)
- Alexis Dorta-Gorrín
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
- Environmental Genetics Department, Ecohydros S.L., 39600 Maliaño, Spain
| | - Jesús Navas-Méndez
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
| | - Mónica Gozalo-Margüello
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
- Microbiology Service of University Hospital Marqués de Valdecilla (HUMV), 39008 Santander, Spain
- CIBER de Enfermedades Infecciosas-CIBERINFEC (CB21/13/00068), Instituto de Salud Carlos III, 28029 Madrid, Spain
| | - Laura Miralles
- Environmental Genetics Department, Ecohydros S.L., 39600 Maliaño, Spain
- Department of Functional Biology, Area of Genetics, Faculty of Medicine, University of Oviedo, 33006 Oviedo, Spain
| | - Lorena García-Hevia
- Department of Molecular Biology, Faculty of Medicine, University of Cantabria (UC), 39011 Santander, Spain
- Instituto de Investigación Valdecilla (IDIVAL), 39011 Santander, Spain
| |
Collapse
|
23
|
Moetlhoa B, Maluleke K, Mathebula EM, Kgarosi K, Nxele SR, Lenonyane B, Mashamba-Thompson T. REASSURED diagnostics at point-of-care in sub-Saharan Africa: A scoping review. PLOS GLOBAL PUBLIC HEALTH 2023; 3:e0001443. [PMID: 37276194 DOI: 10.1371/journal.pgph.0001443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Accepted: 05/12/2023] [Indexed: 06/07/2023]
Abstract
Point-of-care (POC) diagnostics that meet the REASSURED criteria are essential in combating the rapid increase and severity of global health emergencies caused by infectious diseases. However, little is known about whether the REASSURED criteria are implemented in regions known to have a high burden of infectious diseases such as sub-Saharan Africa (SSA). This scoping review maps evidence of the use of REASSURED POC diagnostic tests in SSA. The scoping review was guided by the advanced methodological framework of Arksey and O'Malley, and Levac et al. We searched the following electronic databases for relevant literature: Scopus, Dimensions, ProQuest Central, Google Scholar, and EBSCOhost (MEDLINE, CINAHL, as well as AFRICA-WIDE). Two reviewers independently screened abstracts and full-text articles using the inclusion criteria as reference. We appraised the quality of the included studies using the mixed-method appraisal tool (MMAT) version 2018. We retrieved 138 publications, comprising 134 articles and four grey literature articles. Of these, only five articles were included following abstract and full-text screening. The five included studies were all conducted in SSA. The following themes emerged from the eligible articles: quality assurance on accuracy of REASSURED POC diagnostic tests, sustainability of REASSURED POC diagnostic tests, and local infrastructure capability for delivering REASSURED POC diagnostic tests to end users. All five articles had MMAT scores between 90% and 100%. In conclusion, our scoping review revealed limited published research on REASSURED diagnostics at POC in SSA. We recommend primary studies aimed at investigating the implementation of REASSURED POC diagnostic tests in SSA.
Collapse
Affiliation(s)
- Boitumelo Moetlhoa
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Kuhlula Maluleke
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
| | - Evans M Mathebula
- Faculty of Health Sciences, School of Health Systems and Public Health, University of Pretoria, Pretoria, South Africa
- Medical and Scientific Affairs, Rapid Diagnostics, Infectious Diseases Emerging Markets, Abbot Rapid Diagnostics (Pty) Ltd, Sandton, South Africa
| | - Kabelo Kgarosi
- Faculty of Health Sciences, Department of Library Services, University of Pretoria, Pretoria, South Africa
| | - Siphesihle R Nxele
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Bonolo Lenonyane
- Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | | |
Collapse
|
24
|
Paulose AK, Hou YJ, Huang YS, Chakkalaparambil Dileep N, Chiu CL, Pal A, Kalaimani VM, Lin ZH, Chang CR, Chen CP, Lin YC, Cheng CY, Cheng SH, Cheng CM, Wang YL. Rapid Escherichia coli Cloned DNA Detection in Serum Using an Electrical Double Layer-Gated Field-Effect Transistor-Based DNA Sensor. Anal Chem 2023; 95:6871-6878. [PMID: 37080900 DOI: 10.1021/acs.analchem.2c05719] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
In this study, a rapid diagnosis platform was developed for the detection of Escherichia coli O157:H7. An electrical double layer (EDL)-gated field-effect transistor-based biosensor (BioFET) as a point-of-care testing device is demonstrated with its high sensitivity, portability, high selectivity, quick response, and ease of use. The specially designed ssDNA probe was immobilized on the extended gate electrode to bind the target complementary DNA segment of E. coli, resulting in a sharp drain current change within minutes. The limit of detection for target DNA is validated to a concentration of 1 fM in buffer solution and serum. Meanwhile, the results of a Kelvin probe force microscope were shown to have reduced surface potential of the DNA immobilized sensors before and after the cDNA detection, which is consistent with the decreased drain current of the BioFET. A 1.2 kb E. coli duplex DNA synthesized in plasmid was sonicated and detected in serum samples with the sensor array. Gel electrophoresis was used to confirm the efficiency of sonication by elucidating the length of DNA. Those results show that the EDL-gated BioFET system is a promising platform for rapid identification of pathogens for future clinical needs.
Collapse
Affiliation(s)
- Akhil K Paulose
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Yueh-Ju Hou
- Department of Life Sciences, National University of Kaohsiung, Kaohsiung 811726, Taiwan, ROC
| | - Yu-Shan Huang
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | | | - Chia-Lin Chiu
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Arnab Pal
- International Intercollegiate PhD Program, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Vishal Mani Kalaimani
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Zong-Hong Lin
- Department of Biomedical Engineering, National Taiwan University, Taipei 10617, Taiwan, ROC
| | - Chuang-Rung Chang
- Institute of Biotechnology, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Cheng-Pin Chen
- Department of Infectious Diseases, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 32748, Taiwan
| | - Yi-Chun Lin
- Department of Infectious Diseases, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 32748, Taiwan
| | - Chien-Yu Cheng
- Department of Infectious Diseases, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 32748, Taiwan
| | - Shu-Hsing Cheng
- Department of Infectious Diseases, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan 32748, Taiwan
| | - Chao-Min Cheng
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| | - Yu-Lin Wang
- Institute of Nanoengineering and Microsystems, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
- College of Semiconductor Research, National Tsing Hua University, Hsinchu 30013, Taiwan, ROC
| |
Collapse
|
25
|
Trinh KTL, Do HDK, Lee NY. Recent Advances in Molecular and Immunological Diagnostic Platform for Virus Detection: A Review. BIOSENSORS 2023; 13:bios13040490. [PMID: 37185566 PMCID: PMC10137144 DOI: 10.3390/bios13040490] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/14/2023] [Accepted: 04/18/2023] [Indexed: 05/17/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has caused an ongoing coronavirus disease (COVID-19) outbreak and a rising demand for the development of accurate, timely, and cost-effective diagnostic tests for SARS-CoV-2 as well as other viral infections in general. Currently, traditional virus screening methods such as plate culturing and real-time PCR are considered the gold standard with accurate and sensitive results. However, these methods still require sophisticated equipment, trained personnel, and a long analysis time. Alternatively, with the integration of microfluidic and biosensor technologies, microfluidic-based biosensors offer the ability to perform sample preparation and simultaneous detection of many analyses in one platform. High sensitivity, accuracy, portability, low cost, high throughput, and real-time detection can be achieved using a single platform. This review presents recent advances in microfluidic-based biosensors from many works to demonstrate the advantages of merging the two technologies for sensing viruses. Different platforms for virus detection are classified into two main sections: immunoassays and molecular assays. Moreover, available commercial sensing tests are analyzed.
Collapse
Affiliation(s)
- Kieu The Loan Trinh
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ward 13, District 04, Ho Chi Minh City 70000, Vietnam
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University, 1342 Seongnam-daero, Sujeong-gu, Seongnam-si 13120, Gyeonggi-do, Republic of Korea
| |
Collapse
|
26
|
Lai MY, Zen LPY, Abdul Hamid MH, Jelip J, Mudin RN, Ivan VJS, Francis LNP, Saihidi I, Lau YL. Point-of-Care Diagnosis of Malaria Using a Simple, Purification-Free DNA Extraction Method Coupled with Loop-Mediated Isothermal Amplification-Lateral Flow. Trop Med Infect Dis 2023; 8:199. [PMID: 37104326 PMCID: PMC10140920 DOI: 10.3390/tropicalmed8040199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 03/27/2023] [Accepted: 03/27/2023] [Indexed: 04/28/2023] Open
Abstract
We propose a protocol suitable for point-of-care diagnosis of malaria utilizing a simple and purification-free DNA extraction method with the combination of loop-mediated isothermal amplification assay and lateral flow (LAMP-LF). The multiplex LAMP-LF platform developed here can simultaneously detect Plasmodium knowlesi, P. vivax, P. falciparum, and Plasmodium genus (for P. malariae and P. ovale). Through the capillary effect, the results can be observed by the red band signal on the test and control lines within 5 min. The developed multiplex LAMP-LF was tested with 86 clinical blood samples on-site at Hospital Kapit, Sarawak, Malaysia. By using microscopy as the reference method, the multiplex LAMP-LF showed 100% sensitivity (95% confidence interval (CI): 91.4 to 100.00%) and 97.8% specificity (95% CI: 88.2% to 99.9%). The high sensitivity and specificity of multiplex LAMP-LF make it ideal for use as a point-of-care diagnostic tool. The simple and purification-free DNA extraction protocol can be employed as an alternative DNA extraction method for malaria diagnosis in resource-limited settings. By combining the simple DNA extraction protocol and multiplex LAMP-LF approach, we aim to develop a simple-to-handle and easy-to-read molecular diagnostic tool for malaria in both laboratory and on-site settings.
Collapse
Affiliation(s)
- Meng Yee Lai
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur 50603, Malaysia; (M.Y.L.); (L.P.Y.Z.)
| | - Lee Phone Youth Zen
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur 50603, Malaysia; (M.Y.L.); (L.P.Y.Z.)
| | | | - Jenarun Jelip
- Vector Borne Disease Sector, Ministry of Health, Putrajaya 62590, Malaysia
| | - Rose Nani Mudin
- Vector Borne Disease Sector, Ministry of Health, Putrajaya 62590, Malaysia
| | | | | | - Izreena Saihidi
- Hospital Kapit, Pathology Unit, Jalan Mamora, Kapit 96800, Malaysia
| | - Yee Ling Lau
- Department of Parasitology, Faculty of Medicine, Universiti Malaya, Kuala Lumpur 50603, Malaysia; (M.Y.L.); (L.P.Y.Z.)
| |
Collapse
|
27
|
Borriello M, Tarabella G, D’Angelo P, Liboà A, Barra M, Vurro D, Lombari P, Coppola A, Mazzella E, Perna AF, Ingrosso D. Lab on a Chip Device for Diagnostic Evaluation and Management in Chronic Renal Disease: A Change Promoting Approach in the Patients' Follow Up. BIOSENSORS 2023; 13:373. [PMID: 36979584 PMCID: PMC10046018 DOI: 10.3390/bios13030373] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/06/2023] [Accepted: 03/10/2023] [Indexed: 06/18/2023]
Abstract
Lab-on-a-chip (LOC) systems are miniaturized devices aimed to perform one or several analyses, normally carried out in a laboratory setting, on a single chip. LOC systems have a wide application range, including diagnosis and clinical biochemistry. In a clinical setting, LOC systems can be associated with the Point-of-Care Testing (POCT) definition. POCT circumvents several steps in central laboratory testing, including specimen transportation and processing, resulting in a faster turnaround time. Provider access to rapid test results allows for prompt medical decision making, which can lead to improved patient outcomes, operational efficiencies, patient satisfaction, and even cost savings. These features are particularly attractive for healthcare settings dealing with complicated patients, such as those affected by chronic kidney disease (CKD). CKD is a pathological condition characterized by progressive and irreversible structural or functional kidney impairment lasting for more than three months. The disease displays an unavoidable tendency to progress to End Stage Renal Disease (ESRD), thus requiring renal replacement therapy, usually dialysis, and transplant. Cardiovascular disease (CVD) is the major cause of death in CKD, with a cardiovascular risk ten times higher in these patients than the rate observed in healthy subjects. The gradual decline of the kidney leads to the accumulation of uremic solutes, with negative effect on organs, especially on the cardiovascular system. The possibility to monitor CKD patients by using non-invasive and low-cost approaches could give advantages both to the patient outcome and sanitary costs. Despite their numerous advantages, POCT application in CKD management is not very common, even if a number of devices aimed at monitoring the CKD have been demonstrated worldwide at the lab scale by basic studies (low Technology Readiness Level, TRL). The reasons are related to both technological and clinical aspects. In this review, the main technologies for the design of LOCs are reported, as well as the available POCT devices for CKD monitoring, with a special focus on the most recent reliable applications in this field. Moreover, the current challenges in design and applications of LOCs in the clinical setting are briefly discussed.
Collapse
Affiliation(s)
- Margherita Borriello
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio, 7, 80138 Naples, Italy
| | | | | | - Aris Liboà
- IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy; (G.T.)
| | - Mario Barra
- CNR-SPIN, c/o Dipartimento di Fisica “Ettore Pancini”, P.le Tecchio, 80, 80125 Naples, Italy
| | - Davide Vurro
- IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy; (G.T.)
| | - Patrizia Lombari
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio, 7, 80138 Naples, Italy
| | - Annapaola Coppola
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio, 7, 80138 Naples, Italy
| | - Elvira Mazzella
- Department of Translational Medical Science, University of Campania “Luigi Vanvitelli”, via Via Pansini, Bldg 17, 80131 Naples, Italy
| | - Alessandra F. Perna
- Department of Translational Medical Science, University of Campania “Luigi Vanvitelli”, via Via Pansini, Bldg 17, 80131 Naples, Italy
| | - Diego Ingrosso
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, via L. De Crecchio, 7, 80138 Naples, Italy
| |
Collapse
|
28
|
Kim J, Kim C, Park JS, Lee NE, Lee S, Cho SY, Park C, Yoon DS, Yoo YK, Lee JH. Affordable on-site COVID-19 test using non-powered preconcentrator. Biosens Bioelectron 2023; 222:114965. [PMID: 36493723 PMCID: PMC9715458 DOI: 10.1016/j.bios.2022.114965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 11/24/2022] [Accepted: 11/27/2022] [Indexed: 12/03/2022]
Abstract
A simple, affordable point of care test (POCT) is necessary for on-site detection of coronavirus disease 2019 (COVID-19). The lateral flow assay (LFA) has great potential for use in POCT mainly because of factors such as low time consumption, low cost, and ease of use. However, it lacks sensitivity and limits of detection (LOD), which are essential for early diagnostics. In this study, we proposed a non-powered preconcentrator (NPP) based on nanoelectrokinetics for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Antigen (Ag) lateral flow assay. The non-powered preconcentrator is composed of glass fiber-based composite paper and ion permselective material, and it can be simply operated by force balancing gravitational, capillary, and depletion-induced forces. The proposed approach helps enrich the SARS-CoV-2 viral nucleocapsid (N) proteins based on a 10-min operation, and it improved the LOD by up to 10-fold. The corresponding virus enrichment, which was evaluated using the reverse-transcriptase polymerase chain reaction (RT-PCR), revealed an improvement in ΔCt values > 3. We successfully demonstrated the enhancement of the NPP-assisted LFA, we extended to applying it to clinical samples. Further, we demonstrated an affordable, easy-to-implement form of LFA by simply designing NPP directly on the LFA buffer tube.
Collapse
Affiliation(s)
- Jinhwan Kim
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea
| | - Cheonjung Kim
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea; Department of Electronic Engineering, Catholic Kwandong University, Gangneung-si, Gangwon-do, 25601, Republic of Korea
| | - Jeong Soo Park
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea
| | - Na Eun Lee
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea; Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul, 02841, Republic of Korea
| | - Seungmin Lee
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea; School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea
| | - Sung-Yeon Cho
- Vaccine Bio Research Institute, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea; Division of Infectious Diseases, Department of Internal Medicine, Seoul St. Mary's Hospital, Catholic Hematology Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
| | - Chulmin Park
- Vaccine Bio Research Institute, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Dae Sung Yoon
- School of Biomedical Engineering, Korea University, Seoul, 02841, Republic of Korea.
| | - Yong Kyoung Yoo
- Department of Electronic Engineering, Catholic Kwandong University, Gangneung-si, Gangwon-do, 25601, Republic of Korea.
| | - Jeong Hoon Lee
- Department of Electrical Engineering, Kwangwoon University, Seoul, 01897, Republic of Korea.
| |
Collapse
|
29
|
Quality Assurance for Hepatitis C Virus Point-of-Care Diagnostics in Sub-Saharan Africa. Diagnostics (Basel) 2023; 13:diagnostics13040684. [PMID: 36832172 PMCID: PMC9955859 DOI: 10.3390/diagnostics13040684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 02/15/2023] Open
Abstract
As part of a multinational study to evaluate the Bioline Hepatitis C virus (HCV) point-of-care (POC) testing in sub-Saharan Africa (SSA), this narrative review summarises regulatory standards and quality indicators for validating and approving HCV clinical diagnostics. In addition, this review also provides a summary of their diagnostic evaluations using the REASSURED criteria as the benchmark and its implications on the WHO HCV elimination goals 2030.
Collapse
|
30
|
Pioz MJ, Espinosa RL, Laguna MF, Santamaria B, Murillo AMM, Hueros ÁL, Quintero S, Tramarin L, Valle LG, Herreros P, Bellido A, Casquel R, Holgado M. A review of Optical Point-of-Care devices to Estimate the Technology Transfer of These Cutting-Edge Technologies. BIOSENSORS 2022; 12:bios12121091. [PMID: 36551058 PMCID: PMC9776401 DOI: 10.3390/bios12121091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 11/12/2022] [Accepted: 11/18/2022] [Indexed: 06/07/2023]
Abstract
Despite the remarkable development related to Point-of-Care devices based on optical technology, their difficulties when used outside of research laboratories are notable. In this sense, it would be interesting to ask ourselves what the degree of transferability of the research work to the market is, for example, by analysing the relation between the scientific work developed and the registered one, through patent. In this work, we provide an overview of the state-of-the-art in the sector of optical Point-of-Care devices, not only in the research area but also regarding their transfer to market. To this end, we explored a methodology for searching articles and patents to obtain an indicator that relates to both. This figure of merit to estimate this transfer is based on classifying the relevant research articles in the area and the patents that have been generated from these ones. To delimit the scope of this study, we researched the results of a large enough number of publications in the period from 2015 to 2020, by using keywords "biosensor", "optic", and "device" to obtain the most representative articles from Web of Science and Scopus. Then, we classified them according to a particular classification of the optical PoC devices. Once we had this sampling frame, we defined a patent search strategy to cross-link the article with a registered patent (by surfing Google Patents) and classified them accordingly to the categories described. Finally, we proposed a relative figure called Index of Technology Transference (IoTT), which estimates to what extent our findings in science materialized in published articles are protected by patent.
Collapse
Affiliation(s)
- María Jesús Pioz
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- University of Nebrija, C/del Hostal, Campus Berzosa, 28248 Madrid, Spain
| | - Rocío L. Espinosa
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - María Fe Laguna
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Beatriz Santamaria
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Metch, Chem & Industrial Design Engineering Department, Escuela Técnica Superior de Ingeniería y Diseño Industrial, Universidad Politécnica de Madrid, Ronda de Valencia 3, 28012 Madrid, Spain
| | - Ana María M. Murillo
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
| | - Álvaro Lavín Hueros
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Sergio Quintero
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
| | - Luca Tramarin
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
| | - Luis G Valle
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
| | - Pedro Herreros
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Alberto Bellido
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Multiplex Molecular Diagnostics S.L. C/ Munner 10, 08022 Barcelona, Spain
| | - Rafael Casquel
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| | - Miguel Holgado
- Optics, Photonics and Biophotonics Group, Center for Biomedical Technology, Optics, Universidad Politécnica de Madrid, Campus Montegancedo, Pozuelo de Alarcón, 28223 Madrid, Spain
- Group of Organ and Tissue on-a-Chip and In-Vitro Detection, Health Research Institute of the Hospital Clínico San Carlos IdISSC, C/Profesor Martín Lagos s/n, 4ª _Planta Sur, 28040 Madrid, Spain
- Department of Applied Physics and Materials Engineering, Escuela Técnica Superior de Ingenieros Industriales, Universidad Politécnica de Madrid, C/José Gutiérrez Abascal 2, 28006 Madrid, Spain
| |
Collapse
|
31
|
Saviñon-Flores AI, Saviñon-Flores F, Trejo G, Méndez E, Ţălu Ş, González-Fuentes MA, Méndez-Albores A. A review of cardiac troponin I detection by surface enhanced Raman spectroscopy: Under the spotlight of point-of-care testing. Front Chem 2022; 10:1017305. [PMID: 36311415 PMCID: PMC9608872 DOI: 10.3389/fchem.2022.1017305] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 09/29/2022] [Indexed: 11/29/2022] Open
Abstract
Cardiac troponin I (cTnI) is a biomarker widely related to acute myocardial infarction (AMI), one of the leading causes of death around the world. Point-of-care testing (POCT) of cTnI not only demands a short turnaround time for its detection but the highest accuracy levels to set expeditious and adequate clinical decisions. The analytical technique Surface-enhanced Raman spectroscopy (SERS) possesses several properties that tailor to the POCT format, such as its flexibility to couple with rapid assay platforms like microfluidics and paper-based immunoassays. Here, we analyze the strategies used for the detection of cTnI by SERS considering POCT requirements. From the detection ranges reported in the reviewed literature, we suggest the diseases other than AMI that could be diagnosed with this technique. For this, a section with information about cardiac and non-cardiac diseases with cTnI release, including their release kinetics or cut-off values are presented. Likewise, POCT features, the use of SERS as a POCT technique, and the biochemistry of cTnI are discussed. The information provided in this review allowed the identification of strengths and lacks of the available SERS-based point-of-care tests for cTnI and the disclosing of requirements for future assays design.
Collapse
Affiliation(s)
- Anel I. Saviñon-Flores
- Centro de Química-ICUAP- Posgrado en Ciencias Ambientales, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | | | - G. Trejo
- Laboratory of Composite Materials and Functional Coatings, Center for Research and Technological Development in Electrochemistry (CIDETEQ), Querétaro, Mexico
| | - Erika Méndez
- Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
| | - Ştefan Ţălu
- Technical University of Cluj-Napoca, The Directorate of Research, Development and Innovation Management (DMCDI), Cluj-Napoca, Romania
| | - Miguel A. González-Fuentes
- Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
- *Correspondence: Miguel A. González-Fuentes, ; Alia Méndez-Albores,
| | - Alia Méndez-Albores
- Centro de Química-ICUAP- Posgrado en Ciencias Ambientales, Benemérita Universidad Autónoma de Puebla, Puebla, Mexico
- *Correspondence: Miguel A. González-Fuentes, ; Alia Méndez-Albores,
| |
Collapse
|