51
|
Tao Q, Yi P, Cai Z, Chen Z, Deng Z, Liu R, Feng Y. Ratiometric chemical exchange saturation transfer pH mapping using two iodinated agents with nonequivalent amide protons and a single low saturation power. Quant Imaging Med Surg 2022; 12:3889-3902. [PMID: 35782235 PMCID: PMC9246745 DOI: 10.21037/qims-21-1229] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 04/29/2022] [Indexed: 07/26/2023]
Abstract
BACKGROUND As an essential physiological parameter, pH plays a critical role in maintaining cellular and tissue homeostasis. The ratiometric chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) method using clinically approved iodinated agents has emerged as one of the most promising noninvasive techniques for pH assessment. METHODS In this study, we investigated the ability to use the combination of two different nonequivalent amide protons, chosen from five iodinated agents, namely iodixanol, iohexol, iobitridol, iopamidol, and iopromide, for pH measurement. The ratio of two nonequivalent amide CEST signals was calculated and compared for pH measurements in the range of 5.6 to 7.6. To quantify the CEST signals at 4.3 and 5.5 parts per million (ppm), we employed two analytic methods: magnetization transfer ratio asymmetry and Lorentzian fitting analysis. Lastly, the established protocol was used to measure the pH values in healthy rat kidneys (n=5). RESULTS The combination of iodixanol and iobitridol at a ratio of 1:1 was found to be suitable for pH mapping. The saturation power level (B1) was also investigated, and a low B1 of 1.5 µT was adopted for subsequent pH measurements. Improved precision and an extended pH detection range were achieved using iodixanol and iobitridol (1:1 ratio) and a single low B1 of 1.5 µT in vitro. In vivo renal pH values were measured as 7.23±0.09, 6.55±0.15, and 6.29±0.23 for the cortex, medulla, and calyx, respectively. CONCLUSIONS These results show that the ratiometric CEST method using two iodinated agents with nonequivalent amide protons could be used for in vivo pH mapping of the kidney under a single low B1 saturation power.
Collapse
Affiliation(s)
- Quan Tao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Peiwei Yi
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Zimeng Cai
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Zelong Chen
- Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Zongwu Deng
- CAS Key Laboratory of Nano-Bio Interface and Division of Nanobionics, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou, China
| | - Ruiyuan Liu
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| | - Yanqiu Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- Key Laboratory of Mental Health of the Ministry of Education & Guangdong-Hong Kong-Macao Greater Bay Area Center for Brain Science and Brain-Inspired Intelligence, Southern Medical University, Guangzhou, China
| |
Collapse
|
52
|
Jin T, Chung JJ. Average saturation efficiency filter (ASEF) for CEST imaging. Magn Reson Med 2022; 88:254-265. [PMID: 35344594 PMCID: PMC9172934 DOI: 10.1002/mrm.29211] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 01/06/2022] [Accepted: 02/08/2022] [Indexed: 12/21/2022]
Abstract
PURPOSE Endogenous CEST signal usually has low specificity due to contamination from the magnetization transfer effect and from fast exchanging labile protons with close Larmor frequencies. We propose to improve CEST signal specificity with an average saturation efficiency filter (ASEF). METHODS ASEF measures the difference between CEST signals acquired with similar average irradiation power but largely different duty cycles (DC), for example, a continuous wave or a high DC pulse train versus a low DC one. Simulation and Cr phantom studies were performed to evaluate the characteristics of ASEF for CEST. RESULTS Theoretical and simulation studies show that ASEF can suppress fast exchanging processes, with only a small loss of chemical exchange contrast for slow-to-intermediate exchange rates if the difference in DC is large. In the RF offset range of 2 to 5 ppm with an averaged saturation power of 0.8 and 1.6 microteslas, there is a mismatch of ∼0.1% to 2% in the magnetization transfer signal between saturation by continuous wave and a pulse train with DC = 15% and pulse duration of 24 ms, respectively. This mismatch can be minimized by careful selection of saturation power, pulse duration, and DC differences or by applying a small fudge factor between the 2 irradiation powers. Phantom studies of Cr confirmed that ASEF can minimize the magnetization transfer effect and reduce sensitivity to fast exchange processes. CONCLUSION ASEF can improve the specificity of slow-to-intermediate exchanging CEST signal with a relatively small loss of sensitivity.
Collapse
Affiliation(s)
- Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Julius Juhyun Chung
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
53
|
Breitling J, Korzowski A, Kempa N, Boyd PS, Paech D, Schlemmer HP, Ladd ME, Bachert P, Goerke S. Motion correction for three-dimensional chemical exchange saturation transfer imaging without direct water saturation artifacts. NMR IN BIOMEDICINE 2022; 35:e4720. [PMID: 35233847 DOI: 10.1002/nbm.4720] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 11/25/2021] [Accepted: 02/22/2022] [Indexed: 06/14/2023]
Abstract
In chemical exchange saturation transfer (CEST) MRI, motion correction is compromised by the drastically changing image contrast at different frequency offsets, particularly at the direct water saturation. In this study, a simple extension for conventional image registration algorithms is proposed, enabling robust and accurate motion correction of CEST-MRI data. The proposed method uses weighted averaging of motion parameters from a conventional rigid image registration to identify and mitigate erroneously misaligned images. Functionality of the proposed method was verified by ground truth datasets generated from 10 three-dimensional in vivo measurements at 3 T with simulated realistic random rigid motion patterns and noise. Performance was assessed using two different criteria: the maximum image misalignment as a measure for the robustness against direct water saturation artifacts, and the spectral error as a measure of the overall accuracy. For both criteria, the proposed method achieved the best scores compared with two motion-correction algorithms specifically developed to handle the varying contrasts in CEST-MRI. Compared with a straightforward linear interpolation of the motion parameters at frequency offsets close to the direct water saturation, the proposed method offers better performance in the absence of artifacts. The proposed method for motion correction in CEST-MRI allows identification and mitigation of direct water saturation artifacts that occur with conventional image registration algorithms. The resulting improved robustness and accuracy enable reliable motion correction, which is particularly crucial for an automated and carefree evaluation of spectral CEST-MRI data, e.g., for large patient cohorts or in clinical routines.
Collapse
Affiliation(s)
- Johannes Breitling
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Andreas Korzowski
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Neele Kempa
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Philip S Boyd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Daniel Paech
- Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | | | - Mark E Ladd
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
- Faculty of Medicine, University of Heidelberg, Heidelberg, Germany
| | - Peter Bachert
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Steffen Goerke
- Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
54
|
Bardin S, Lecis M, Boido D, Boutin C, Baron G, Aldini G, Berthault P, Boumezbeur F, Ciobanu L. In vivo detection of carnosine and its derivatives using chemical exchange saturation transfer. Magn Reson Med 2022; 88:1314-1323. [PMID: 35526234 PMCID: PMC9320878 DOI: 10.1002/mrm.29282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/29/2022] [Accepted: 04/11/2022] [Indexed: 11/09/2022]
Abstract
Purpose To detect carnosine, anserine and homocarnosine in vivo with chemical exchange saturation transfer (CEST) at 17.2 T. Methods CEST MR acquisitions were performed using a CEST‐linescan sequence developed in‐house and optimized for carnosine detection. In vivo CEST data were collected from three different regions of interest (the lower leg muscle, the olfactory bulb and the neocortex) of eight rats. Results The CEST effect for carnosine, anserine and homocarnosine was characterized in phantoms, demonstrating the possibility to separate individual contributions by employing high spectral resolution (0.005 ppm) and low CEST saturation power (0.15 μT). The CEST signature of these peptides was evidenced, in vivo, in the rat brain and skeletal muscle. The presence of carnosine and anserine in the muscle was corroborated by in vivo localized spectroscopy (MRS). However, the sensitivity of MRS was insufficient for carnosine and homocarnosine detection in the brain. The absolute amounts of carnosine and derivatives in the investigated tissues were determined by liquid chromatography–electrospray ionization‐tandem mass spectrometry using isotopic dilution standard methods and were in agreement with the CEST results. Conclusion The robustness of the CEST‐linescan approach and the favorable conditions for CEST at ultra‐high magnetic field allowed the in vivo CEST MR detection of carnosine and related peptides. This approach could be useful to investigate noninvasively the (patho)‐physiological roles of these molecules.
Collapse
Affiliation(s)
- Solène Bardin
- NeuroSpin, UMR CEA/CNRS 9027 Paris‐Saclay University Gif‐sur‐Yvette France
| | - Michele Lecis
- NeuroSpin, UMR CEA/CNRS 9027 Paris‐Saclay University Gif‐sur‐Yvette France
| | - Davide Boido
- NeuroSpin, UMR CEA/CNRS 9027 Paris‐Saclay University Gif‐sur‐Yvette France
| | - Céline Boutin
- IRAMIS, NIMBE, UMR CEA/CNRS 3685 Laboratoire Structure et Dynamique par Résonance Magnétique Gif‐sur‐Yvette France
| | - Giovanna Baron
- Department of Pharmaceutical Sciences, Medicinal Chemistry Section "Pietro Pratesi” University of Milan Milan Italy
| | - Giancarlo Aldini
- Department of Pharmaceutical Sciences, Medicinal Chemistry Section "Pietro Pratesi” University of Milan Milan Italy
| | - Patrick Berthault
- IRAMIS, NIMBE, UMR CEA/CNRS 3685 Laboratoire Structure et Dynamique par Résonance Magnétique Gif‐sur‐Yvette France
| | - Fawzi Boumezbeur
- NeuroSpin, UMR CEA/CNRS 9027 Paris‐Saclay University Gif‐sur‐Yvette France
| | - Luisa Ciobanu
- NeuroSpin, UMR CEA/CNRS 9027 Paris‐Saclay University Gif‐sur‐Yvette France
| |
Collapse
|
55
|
Zhou J, Zaiss M, Knutsson L, Sun PZ, Ahn SS, Aime S, Bachert P, Blakeley JO, Cai K, Chappell MA, Chen M, Gochberg DF, Goerke S, Heo HY, Jiang S, Jin T, Kim SG, Laterra J, Paech D, Pagel MD, Park JE, Reddy R, Sakata A, Sartoretti-Schefer S, Sherry AD, Smith SA, Stanisz GJ, Sundgren PC, Togao O, Vandsburger M, Wen Z, Wu Y, Zhang Y, Zhu W, Zu Z, van Zijl PCM. Review and consensus recommendations on clinical APT-weighted imaging approaches at 3T: Application to brain tumors. Magn Reson Med 2022; 88:546-574. [PMID: 35452155 PMCID: PMC9321891 DOI: 10.1002/mrm.29241] [Citation(s) in RCA: 101] [Impact Index Per Article: 33.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/26/2022] [Accepted: 03/02/2022] [Indexed: 12/16/2022]
Abstract
Amide proton transfer-weighted (APTw) MR imaging shows promise as a biomarker of brain tumor status. Currently used APTw MRI pulse sequences and protocols vary substantially among different institutes, and there are no agreed-on standards in the imaging community. Therefore, the results acquired from different research centers are difficult to compare, which hampers uniform clinical application and interpretation. This paper reviews current clinical APTw imaging approaches and provides a rationale for optimized APTw brain tumor imaging at 3 T, including specific recommendations for pulse sequences, acquisition protocols, and data processing methods. We expect that these consensus recommendations will become the first broadly accepted guidelines for APTw imaging of brain tumors on 3 T MRI systems from different vendors. This will allow more medical centers to use the same or comparable APTw MRI techniques for the detection, characterization, and monitoring of brain tumors, enabling multi-center trials in larger patient cohorts and, ultimately, routine clinical use.
Collapse
Affiliation(s)
- Jinyuan Zhou
- Division of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Moritz Zaiss
- Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Institute of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Linda Knutsson
- Division of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Medical Radiation Physics, Lund University, Lund, Sweden.,F.M. Kirby Research Center for Functional Brain Imaging, Hugo W. Moser Research Institute at Kennedy Krieger, Baltimore, Maryland, USA
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia, USA
| | - Sung Soo Ahn
- Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, South Korea
| | - Silvio Aime
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Peter Bachert
- Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany.,Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany
| | - Jaishri O Blakeley
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Michael A Chappell
- Mental Health and Clinical Neurosciences and Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, UK.,Nottingham Biomedical Research Centre, Queen's Medical Centre, University of Nottingham, Nottingham, UK
| | - Min Chen
- Department of Radiology, Beijing Hospital, National Center of Gerontology, Beijing, China
| | - Daniel F Gochberg
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Physics, Vanderbilt University, Nashville, Tennessee, USA
| | - Steffen Goerke
- Department of Medical Physics in Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Hye-Young Heo
- Division of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Shanshan Jiang
- Division of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Tao Jin
- Department of Radiology, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Seong-Gi Kim
- Center for Neuroscience Imaging Research, Institute for Basic Science and Department of Biomedical Engineering, Sungkyunkwan University, Suwon, South Korea
| | - John Laterra
- Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Hugo W. Moser Research Institute at Kennedy Krieger, Baltimore, Maryland, USA
| | - Daniel Paech
- Department of Radiology, German Cancer Research Center, Heidelberg, Germany.,Clinic for Neuroradiology, University Hospital Bonn, Bonn, Germany
| | - Mark D Pagel
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | - Ji Eun Park
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| | - Ravinder Reddy
- Center for Advance Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Akihiko Sakata
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | | | - A Dean Sherry
- Advanced Imaging Research Center and Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.,Department of Chemistry and Biochemistry, University of Texas at Dallas, Richardson, Texas, USA
| | - Seth A Smith
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee, USA
| | - Greg J Stanisz
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Pia C Sundgren
- Department of Diagnostic Radiology/Clinical Sciences Lund, Lund University, Lund, Sweden.,Lund University Bioimaging Center, Lund University, Lund, Sweden.,Department of Medical Imaging and Physiology, Skåne University Hospital, Lund University, Lund, Sweden
| | - Osamu Togao
- Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | - Zhibo Wen
- Department of Radiology, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China
| | - Wenzhen Zhu
- Department of Radiology, Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science (VUIIS), Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Peter C M van Zijl
- Division of MR Research, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,F.M. Kirby Research Center for Functional Brain Imaging, Hugo W. Moser Research Institute at Kennedy Krieger, Baltimore, Maryland, USA
| |
Collapse
|
56
|
Liu Z, Yang Q, Luo H, Luo D, Qian L, Liu X, Zheng H, Sun PZ, Wu Y. Demonstration of fast and equilibrium human muscle creatine CEST imaging at 3 T. Magn Reson Med 2022; 88:322-331. [PMID: 35324024 DOI: 10.1002/mrm.29223] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/23/2022] [Accepted: 02/20/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE Creatine chemical exchange saturation transfer (CrCEST) MRI is used increasingly in muscle imaging. However, the CrCEST measurement depends on the RF saturation duration (Ts) and relaxation delay (Td), and it is challenging to compare the results of different scan parameters. Therefore, this study aims to evaluate the quasi-steady-state (QUASS) CrCEST MRI on clinical 3T scanners. METHODS T1 and CEST MRI scans of Ts/Td of 1 s/1 s and 2 s/2 s were obtained from a multi-compartment creatine phantom and 5 healthy volunteers. The CrCEST effect was quantified with asymmetry analysis in the phantom, whereas 5-pool Lorentzian fitting was applied to isolate creatine from phosphocreatine, amide proton transfer, combined magnetization transfer and nuclear Overhauser enhancement effects, and direct water saturation in four major muscle groups of the lower leg. The routine and QUASS CrCEST measurements were compared under two different imaging conditions. Paired Student's t-test was performed with p-values less than 0.05 considered statistically significant. RESULTS The phantom study showed a substantial influence of Ts/Td on the routine CrCEST quantification (p = 0.02), and such impact was mitigated with the QUASS algorithm (p = 0.20). The volunteer experiment showed that the routine CrCEST, amide proton transfer, and combined magnetization transfer and nuclear Overhauser enhancement effects increased significantly with Ts and Td (p < 0.05) and were significantly smaller than the corresponding QUASS indices (p < 0.01). In comparison, the QUASS CrCEST MRI showed little dependence on Ts and Td, indicating its robustness and accuracy. CONCLUSION The QUASS CrCEST MRI is feasible to provide fast and accurate muscle creatine imaging.
Collapse
Affiliation(s)
- Zhou Liu
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Qian Yang
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Honghong Luo
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Dehong Luo
- Department of Radiology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China
| | - Long Qian
- MR Research, GE Healthcare, Beijing, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Phillip Zhe Sun
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
57
|
Brain pH Measurement Using AACID CEST MRI Incorporating the 2 ppm Amine Resonance. Tomography 2022; 8:730-739. [PMID: 35314637 PMCID: PMC8938777 DOI: 10.3390/tomography8020060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/23/2022] [Accepted: 03/01/2022] [Indexed: 11/17/2022] Open
Abstract
Many pathological conditions lead to altered intracellular pH (pHi) disrupting normal cellular functions. The chemical exchange saturation transfer (CEST) method, known as Amine and Amide Concentration Independent Detection (AACID), can produce image contrast that is predominantly dependent on tissue intracellular pHi. The AACID value is linearly related to the ratio of the 3.5 ppm amide CEST effect and the 2.75 ppm amine CEST effect in the physiological range. However, the amine CEST effect at 2 ppm is often more clearly defined in vivo, and may provide greater sensitivity to pH changes. The purpose of the current study was to compare AACID measurement precision utilizing the 2.0 and 2.75 ppm amine CEST effects. We hypothesized that the 2.0 ppm amine CEST resonance would produce measurements with greater sensitivity to pH changes. In the current study, we compare the range of the AACID values obtained in 24 mice with brain tumors and in normal tissue using the 2 ppm and 2.75 ppm amine resonances. All CEST data were acquired on a 9.4T MRI scanner. The AACID measurement range increased by 39% when using the 2 ppm amine resonance compared to the 2.75 ppm resonance, with decreased measurement variability across the brain. These data indicate that in vivo pH measurements made using AACID CEST can be enhanced by incorporating the 2 ppm amine resonance. This approach should be considered for pH measurements made over short intervals when no changes are expected in the concentration of metabolites that contribute to the 2 ppm amine resonance.
Collapse
|
58
|
Huang J, Chen Z, Park SW, Lai JHC, Chan KWY. Molecular Imaging of Brain Tumors and Drug Delivery Using CEST MRI: Promises and Challenges. Pharmaceutics 2022; 14:451. [PMID: 35214183 PMCID: PMC8880023 DOI: 10.3390/pharmaceutics14020451] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 12/10/2022] Open
Abstract
Chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) detects molecules in their natural forms in a sensitive and non-invasive manner. This makes it a robust approach to assess brain tumors and related molecular alterations using endogenous molecules, such as proteins/peptides, and drugs approved for clinical use. In this review, we will discuss the promises of CEST MRI in the identification of tumors, tumor grading, detecting molecular alterations related to isocitrate dehydrogenase (IDH) and O-6-methylguanine-DNA methyltransferase (MGMT), assessment of treatment effects, and using multiple contrasts of CEST to develop theranostic approaches for cancer treatments. Promising applications include (i) using the CEST contrast of amide protons of proteins/peptides to detect brain tumors, such as glioblastoma multiforme (GBM) and low-grade gliomas; (ii) using multiple CEST contrasts for tumor stratification, and (iii) evaluation of the efficacy of drug delivery without the need of metallic or radioactive labels. These promising applications have raised enthusiasm, however, the use of CEST MRI is not trivial. CEST contrast depends on the pulse sequences, saturation parameters, methods used to analyze the CEST spectrum (i.e., Z-spectrum), and, importantly, how to interpret changes in CEST contrast and related molecular alterations in the brain. Emerging pulse sequence designs and data analysis approaches, including those assisted with deep learning, have enhanced the capability of CEST MRI in detecting molecules in brain tumors. CEST has become a specific marker for tumor grading and has the potential for prognosis and theranostics in brain tumors. With increasing understanding of the technical aspects and associated molecular alterations detected by CEST MRI, this young field is expected to have wide clinical applications in the near future.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (J.H.); (Z.C.); (S.-W.P.); (J.H.C.L.)
| | - Zilin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (J.H.); (Z.C.); (S.-W.P.); (J.H.C.L.)
| | - Se-Weon Park
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (J.H.); (Z.C.); (S.-W.P.); (J.H.C.L.)
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Joseph H. C. Lai
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (J.H.); (Z.C.); (S.-W.P.); (J.H.C.L.)
| | - Kannie W. Y. Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China; (J.H.); (Z.C.); (S.-W.P.); (J.H.C.L.)
- Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
- Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA
- Shenzhen Research Institute, City University of Hong Kong, Shenzhen 518057, China
- Tung Biomedical Science Centre, City University of Hong Kong, Hong Kong, China
| |
Collapse
|
59
|
Cui J, Zhao Y, Wang F, Gochberg DF, Zu Z. Contribution of blood to nuclear Overhauser effect at -1.6 ppm. Magn Reson Med 2022; 87:409-416. [PMID: 34480767 PMCID: PMC8616842 DOI: 10.1002/mrm.28973] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 07/19/2021] [Accepted: 07/26/2021] [Indexed: 01/04/2023]
Abstract
PURPOSE A relayed nuclear Overhauser enhancement (rNOE) saturation transfer effect at around -1.6 ppm from water, termed NOE(-1.6), was previously reported in rat and human brain, and some publications suggest that it may be related to blood. Here, we studied whether the NOE(-1.6) arises from blood through in vivo and ex vivo experiments. METHODS To evaluate the contribution from in vivo blood to NOE(-1.6), intravascular signals in rat brain were suppressed by two approaches: (1) signal acquisition with a diffusion-weighting of b = 400 s/mm2 ; (2) intravascular injection of 5 mg/kg monocrystalline iron oxide nanoparticle (MION). Ex vivo blood sample was also prepared. The signals were acquired using a chemical exchange saturation transfer (CEST) pulse sequence. Multiple-pool Lorentzian fitting of CEST Z-spectra was performed to quantify the NOE(-1.6) signal. RESULTS There are no significant variations in the fitted in vivo NOE(-1.6) signals when measured with or without diffusion-weighting, but significant signal decease does occur after injection of MION. The NOE(-1.6) signal from ex vivo blood is weaker than that from in vivo tissues. CONCLUSION Considering the relatively small volume of blood in brain, the in vivo experiments with diffusion weighting and the ex vivo experiments both suggest that the NOE(-1.6) is not mainly from blood. The mechanism for the in vivo experiments with MION are less clear. MION not only suppresses MR signals from intravascular space, but changes the susceptibility in the perivascular space. This result suggests that although the NOE(-1.6) is not mainly from blood, it may be vasculature dependent.
Collapse
Affiliation(s)
- Jing Cui
- Vanderbilt University Institute of Imaging Science,
Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Yu Zhao
- Vanderbilt University Institute of Imaging Science,
Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Feng Wang
- Vanderbilt University Institute of Imaging Science,
Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| | - Daniel F. Gochberg
- Vanderbilt University Institute of Imaging Science,
Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
- Deparment of Physics and Astronomy, Vanderbilt University,
Nashville, US
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science,
Nashville, US
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, US
| |
Collapse
|
60
|
Orzyłowska A, Oakden W. Saturation Transfer MRI for Detection of Metabolic and Microstructural Impairments Underlying Neurodegeneration in Alzheimer's Disease. Brain Sci 2021; 12:53. [PMID: 35053797 PMCID: PMC8773856 DOI: 10.3390/brainsci12010053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 12/21/2021] [Accepted: 12/25/2021] [Indexed: 01/08/2023] Open
Abstract
Alzheimer's disease (AD) is one of the most common causes of dementia and difficult to study as the pool of subjects is highly heterogeneous. Saturation transfer (ST) magnetic resonance imaging (MRI) methods are quantitative modalities with potential for non-invasive identification and tracking of various aspects of AD pathology. In this review we cover ST-MRI studies in both humans and animal models of AD over the past 20 years. A number of magnetization transfer (MT) studies have shown promising results in human brain. Increased computing power enables more quantitative MT studies, while access to higher magnetic fields improves the specificity of chemical exchange saturation transfer (CEST) techniques. While much work remains to be done, results so far are very encouraging. MT is sensitive to patterns of AD-related pathological changes, improving differential diagnosis, and CEST is sensitive to particular pathological processes which could greatly assist in the development and monitoring of therapeutic treatments of this currently incurable disease.
Collapse
Affiliation(s)
- Anna Orzyłowska
- Department of Neurosurgery and Paediatric Neurosurgery, Medical University of Lublin, Jaczewskiego 8 (SPSK 4), 20-090 Lublin, Poland
| | - Wendy Oakden
- Physical Sciences, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada;
| |
Collapse
|
61
|
Huang J, Lai JHC, Tse KH, Cheng GWY, Liu Y, Chen Z, Han X, Chen L, Xu J, Chan KWY. Deep neural network based CEST and AREX processing: Application in imaging a model of Alzheimer's disease at 3 T. Magn Reson Med 2021; 87:1529-1545. [PMID: 34657318 DOI: 10.1002/mrm.29044] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 08/26/2021] [Accepted: 09/22/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE To optimize and apply deep neural network based CEST (deepCEST) and apparent exchange dependent-relaxation (deepAREX) for imaging the mouse brain with Alzheimer's disease (AD) at 3T MRI. METHODS CEST and T1 data of central and anterior brain slices of 10 AD mice and 10 age-matched wild type (WT) mice were acquired at a 3T animal MRI scanner. The networks of deepCEST/deepAREX were optimized and trained on the WT data. The CEST/AREX contrasts of AD and WT mice predicted by the networks were analyzed and further validated by immunohistochemistry. RESULTS After optimization and training on CEST data of WT mice, deepCEST/deepAREX could rapidly (~1 s) generate precise CEST and AREX results for unseen CEST data of AD mice, indicating the accuracy and generalization of the networks. Significant lower amide weighted (3.5 ppm) signal related to amyloid β-peptide (Aβ) plaque depositions, which was validated by immunohistochemistry results, was detected in both central and anterior brain slices of AD mice compared to WT mice. Decreased magnetization transfer (MT) signal was also found in AD mice especially in the anterior slice. CONCLUSION DeepCEST/deepAREX could rapidly generate accurate CEST/AREX contrasts in animal study. The well-optimized deepCEST/deepAREX have potential for AD differentiation at 3T MRI.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Joseph H C Lai
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kai-Hei Tse
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Gerald W Y Cheng
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Yang Liu
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.,Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China
| | - Zilin Chen
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xiongqi Han
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Lin Chen
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.,Hong Kong Centre for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, China.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| |
Collapse
|
62
|
Cui J, Afzal A, Zu Z. Comparative evaluation of polynomial and Lorentzian lineshape-fitted amine CEST imaging in acute ischemic stroke. Magn Reson Med 2021; 87:837-849. [PMID: 34590729 PMCID: PMC9293005 DOI: 10.1002/mrm.29030] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 08/06/2021] [Accepted: 09/09/2021] [Indexed: 12/13/2022]
Abstract
Purpose Chemical exchange saturation transfer signals from amines are sensitive to pH, and detection of these signals can serve as an alternative pH imaging method to amide proton transfer (APT). However, conflicting results regarding amine CEST imaging at 2 ppm in ischemic stroke have been reported. Here, we correlated amine CEST with APT in animal stroke models to evaluate its specificity to pH, and investigated the reason for the different results through simulations and sample studies. Methods A three‐point quantification method was used to quantify APT. A polynomial fit method and a multiple‐pool Lorentzian fit method were used to quantify amine CEST. Samples of creatine and glutamate were prepared to study the different CEST effects from arginine amine and fast exchanging pools. Samples of tissue homogenates with different pH were prepared to study the variation in CEST signals due only to changes in pH. Results The polynomial fit of amine CEST at 2 ppm had a significant correlation with APT, whereas the Lorentzian fit did not. Further studies showed that arginine amine contributed to the polynomial fit, whereas both the arginine amine and the fast exchanging pools contributed to the Lorentzian fit with their CEST effects varying in opposite directions after stroke. The CEST signal from the fast exchanging pool decreased, probably due to the reduced pool concentration but not pH. Conclusion The variation in opposite directions led to an insignificant correlation of the Lorentzian fit of amine CEST with APT and the different results in different experimental conditions.
Collapse
Affiliation(s)
- Jing Cui
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Aqeela Afzal
- Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, Tennessee, USA.,Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA
| |
Collapse
|
63
|
BADE AN, GENDELMAN HE, MCMILLAN J, LIU Y. Chemical exchange saturation transfer for detection of antiretroviral drugs in brain tissue. AIDS 2021; 35:1733-1741. [PMID: 34049358 PMCID: PMC8373768 DOI: 10.1097/qad.0000000000002960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE Antiretroviral drug theranostics facilitates the monitoring of biodistribution and efficacy of therapies designed to target HIV type-1 (HIV-1) reservoirs. To this end, we have now deployed intrinsic drug chemical exchange saturation transfer (CEST) contrasts to detect antiretroviral drugs within the central nervous system (CNS). DESIGN AND METHODS CEST effects for lamivudine (3TC) and emtricitabine (FTC) were measured by asymmetric magnetization transfer ratio analyses. The biodistribution of 3TC in different brain sub-regions of C57BL/6 mice treated with lipopolysaccharides was determined using MRI. CEST effects of 3TC protons were quantitated by Lorentzian fitting analysis. 3TC levels in plasma and brain regions were measured using ultraperformance liquid chromatography tandem mass spectrometry to affirm the CEST test results. RESULTS CEST effects of the hydroxyl and amino protons in 3TC and FTC linearly correlated to drug concentrations. 3TC was successfully detected in vivo in brain sub-regions by MRI. The imaging results were validated by measurements of CNS drug concentrations. CONCLUSION CEST contrasts can be used to detect antiretroviral drugs using MRI. Such detection can be used to assess spatial--temporal drug biodistribution. This is most notable within the CNS where drug biodistribution may be more limited with the final goal of better understanding antiretroviral drug-associated efficacy and potential toxicity.
Collapse
Affiliation(s)
- Aditya N. BADE
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68198 USA
| | - Howard E. GENDELMAN
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68198 USA
| | - JoEllyn MCMILLAN
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68198 USA
| | - Yutong LIU
- Department of Pharmacology and Experimental Neuroscience, University of Nebraska Medical Center, Omaha, NE 68198 USA
- Department of Radiology, University of Nebraska Medical Center, Omaha, NE 68198 USA
| |
Collapse
|
64
|
Sun PZ. Quasi-steady-state chemical exchange saturation transfer (QUASS CEST) MRI analysis enables T 1 normalized CEST quantification - Insight into T 1 contribution to CEST measurement. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2021; 329:107022. [PMID: 34144360 PMCID: PMC8316384 DOI: 10.1016/j.jmr.2021.107022] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 05/29/2021] [Accepted: 06/07/2021] [Indexed: 05/26/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI depends not only on the labile proton concentration and exchange rate but also on relaxation rates, particularly T1 relaxation time. However, T1 normalization has shown to be not straightforward under non-steady-state conditions and in the presence of radiofrequency spillover effect. Our study aimed to test if the combined use of the new quasi-steady-state (QUASS) analysis and inverse CEST calculation facilitates T1 normalization for improved CEST quantification. The CEST signal was simulated with Bloch-McConnell equations, and the apparent CEST, QUASS CEST, and the inverse CEST effects were calculated. T1-normalized CEST effects were tested for their specificity to the underlying CEST system (i.e., labile proton ratio and exchange rate). CEST experiments were performed from a 9-vial phantom of independently varied concentrations of creatine (20, 40, and 60 mM) and manganese chloride (20, 30, and 40 µM) under a range of RF saturation amplitudes (0.5-4 µT) and durations (1-4 s). The simulation showed that while T1 normalization of the apparent CEST effect was subject to noticeable T1 contamination, the T1-normalized inverse QUASS CEST effect had little T1 dependence. The experimental data were analyzed using a multiple linear regression model, showing that T1-normalized inverse QUASS analysis significantly depended on creatine concentration and saturation power (P < 0.05), not on manganese chloride concentration and saturation duration, advantageous over other CEST indices. The QUASS CEST algorithm reconstructs the steady-state CEST effect, enabling T1-normalized inverse CEST effect calculation for improved quantification of the underlying CEST system.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, United States; Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta GA, United States.
| |
Collapse
|
65
|
Sui R, Chen L, Li Y, Huang J, Chan KWY, Xu X, van Zijl PCM, Xu J. Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition. Magn Reson Med 2021; 86:893-906. [PMID: 33772859 PMCID: PMC8076068 DOI: 10.1002/mrm.28770] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Revised: 02/15/2021] [Accepted: 02/18/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE To develop a steady-state saturation with radial readout chemical exchange saturation transfer (starCEST) for acquiring CEST images at 3 Tesla (T). The polynomial Lorentzian line-shape fitting approach was further developed for extracting amideCEST intensities at this field. METHOD StarCEST MRI using periodically rotated overlapping parallel lines with enhanced reconstruction-based spatial sampling was implemented to acquire Z-spectra that are robust to brain motion. Multi-linear singular value decomposition postprocessing was applied to enhance the CEST SNR. The egg white phantom studies were performed at 3T to reveal the contributions to the 3.5 ppm CEST signal. Based on the phantom validation, the amideCEST peak was quantified using the polynomial Lorentzian line-shape fitting, which exploits the inverse relationship between Z-spectral intensity and the longitudinal relaxation rate in the rotating frame. The 3D turbo spin echo CEST was also performed to compare with the starCEST method. RESULTS The amideCEST peak showed a negligible peak B1 dependence between 1.2 µT and 2.4 µT. The amideCEST images acquired with starCEST showed much improved image quality, SNR, and motion robustness compared to the conventional 3D turbo spin echo CEST method with the same scan time. The amideCEST contrast extracted by the polynomial Lorentzian line-shape fitting method trended toward a stronger gray matter signal (1.32% ± 0.30%) than white matter (0.92% ± 0.08%; P = .02, n = 5). When calculating the magnetization transfer contrast and T1 -corrected rotating frame relaxation rate maps, amideCEST again was not significantly different for white matter and gray matter. CONCLUSION Rapid multi-slice amideCEST mapping can be achieved by the starCEST method (< 5 min) at 3T by combing with the polynomial Lorentzian line-shape fitting method.
Collapse
Affiliation(s)
- Ran Sui
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Lin Chen
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Yuguo Li
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jianpan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Kannie W. Y. Chan
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xiang Xu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Peter C. M. van Zijl
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
66
|
Su C, Xu S, Lin D, He H, Chen Z, Damen FC, Ke C, Lv X, Cai K. Multi-parametric Z-spectral MRI may have a good performance for glioma stratification in clinical patients. Eur Radiol 2021; 32:101-111. [PMID: 34272981 DOI: 10.1007/s00330-021-08175-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 06/13/2021] [Accepted: 06/28/2021] [Indexed: 12/30/2022]
Abstract
OBJECTIVES To comprehensively and noninvasively risk-stratify glioma grade, isocitrate dehydrogenase (IDH) genotype, and 1p/19q codeletion status using multi-contrast Z-spectral magnetic resonance imaging (MRI). METHODS One hundred and thirteen patients with glioma were retrospectively included. Multiple contrasts contributing to Z-spectra, including direct saturation of water (DSW), semi-solid magnetization transfer contrast (MTC), amide proton transfer (APT) effect, aliphatic nuclear Overhauser effect, and the 2-ppm chemical exchange saturation transfer peak (CEST@2ppm), were fitted with five individual Lorentzian functions. Z-spectral contrasts were compared according to the three most important risk stratifications: tumor grade, IDH genotype, and 1p/19q codeletion status. We further investigated the differentiation of 1p/19q codeletion status within IDH mutant gliomas. The stratification performance of individual Z-spectral contrasts and their combination was quantified using receiver operating characteristic (ROC) analyses. RESULTS DSW was significantly different within grade, IDH genotypes, and 1p/19q codeletion status. APT was significantly different with grade and IDH mutation, but not with 1p/19q subtypes. CEST@2ppm was only significantly different with 1p/19q codeletion subtypes. DSW and CEST@2ppm were the two Z-spectral contrasts able to differentiate 1p/19q codeletion subtypes within IDH mutant gliomas. For differentiating glioma grades using ROC analyses, DSW achieved the largest AUC. For differentiating IDH genotypes, DSW and APT achieved comparable AUCs. DSW was the best metric for differentiating 1p/19q codeletion status within all patients and within the IDH mutant patients. Combining all Z-spectral contrasts improved sensitivity and specificity for all risk stratifications. CONCLUSIONS Multi-parametric Z-spectral MRI serves as a useful, comprehensive, and noninvasive imaging technique for glioma stratification in clinical patients. KEY POINTS • Multiple contrasts contributing to Z-spectra were separately fitted with Lorentzian functions. • Z-spectral contrasts were compared within the three most important and common tumor risk stratifications for gliomas: tumor grade, IDH genotype, and 1p/19q codeletion status. • The stratification performance of individual Z-spectral contrasts and their combination was quantified using receiver operating characteristic analyses, which found Z-spectral MRI to be a useful and comprehensive imaging biomarker for glioma stratification.
Collapse
Affiliation(s)
- Changliang Su
- Department of Medical Imaging, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China
| | - Shijie Xu
- Department of Neurosurgery, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China
| | - Danlin Lin
- Department of Medical Imaging, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China
| | - Haoqiang He
- Department of Medical Imaging, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China
| | - Zhenghe Chen
- Department of Neurosurgery, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China
| | - Frederick C Damen
- Department of Radiology College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| | - Chao Ke
- Department of Neurosurgery, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China.
| | - Xiaofei Lv
- Department of Medical Imaging, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, 651 Dongfeng Road East, 510060, Guangzhou, China.
| | - Kejia Cai
- Department of Radiology College of Medicine, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
67
|
Debnath A, Gupta RK, Reddy R, Singh A. Effect of offset-frequency step size and interpolation methods on chemical exchange saturation transfer MRI computation in human brain. NMR IN BIOMEDICINE 2021; 34:e4468. [PMID: 33543519 DOI: 10.1002/nbm.4468] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Accepted: 12/08/2020] [Indexed: 06/12/2023]
Abstract
Chemical exchange saturation transfer (CEST) MRI is a non-invasive molecular imaging technique with potential applications in pre-clinical and clinical studies. Applications of amide proton transfer-weighted (APT-w), glutamate-weighted (Glu-w) and creatine-weighted (Cr-w) CEST, among others, have been reported. In general, CEST data are acquired at multiple offset-frequencies. In reported studies, different offset-frequency step sizes and interpolation methods have been used during B0 inhomogeneity correction of data. The objective of the current study was to evaluate the effects of different step sizes and interpolation methods on CEST value computation. In the current study, simulation (Glu-w, Cr-w and APT-w) and experimental data from the brain were used. Experimental CEST data (Glu-w) were acquired from human volunteers at 7 T and brain tumor patients (APT-w) at 3 T. During B0 inhomogeneity correction, different interpolation methods (polynomial [degree-1, 2 and 3], cubic-Hermite, cubic-spline and smoothing-spline) were compared. CEST values were computed using asymmetry analysis. The effects of different step sizes and interpolation methods were evaluated using coefficient of variation (CV), normalized mean square error (nMSE) and coefficient of correlation parameters. Additionally, an optimum interpolation method for APT-w values was selected based upon fitting accuracy, T-test, receiver operating characteristic analysis, and its diagnostic performance in differentiating low-grade and high-grade tumors. CV and nMSE increase with an increase in step size irrespective of the interpolation method (except for cubic-Hermite and cubic-spline). The nMSE of Cr-w and Glu-w CEST values were least for polynomial (degree-2 and 3). The quality of Glu-w CEST maps became coarse with the increase in step size. There was a significant difference (P < .05) between low-grade and high-grade tumors using polynomial interpolation (degree-1, 2 and 3); however, linear interpolation outperforms other methods for APT-w data, providing the highest sensitivity and specificity. In conclusion, depending upon the saturation parameters and field strength, optimization of step size and interpolation should be carried out for different CEST metabolites/molecules. Glu-w, Cr-w and APT-w CEST data should be acquired with a step size of between 0.2 and 0.3 ppm. For B0 inhomogeneity correction, polynomial (degree-2) should be used for Glu-w and Cr-w CEST data at 7 T and linear interpolation should be used for APT-w data at 3 T for a limited frequency range.
Collapse
Affiliation(s)
- Ayan Debnath
- Center for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| | | | - Ravinder Reddy
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Anup Singh
- Center for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India
- All India Institute of Medical Science, Delhi, India
| |
Collapse
|
68
|
Li L, Zhou Z, Xiong W, Fang J, Scotti A, Shaghaghi M, Zhu W, Cai K. Characterization of microenvironmental changes in the intervertebral discs of patients with chronic low back pain using multiparametric MRI contrasts extracted from Z-spectrum. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2021; 30:1063-1071. [PMID: 33475842 PMCID: PMC11421479 DOI: 10.1007/s00586-021-06733-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2020] [Revised: 01/02/2021] [Accepted: 01/11/2021] [Indexed: 11/24/2022]
Abstract
PURPOSE Z-spectral MRI data were analyzed to produce multiparametric metabolic and microenvironmental contrasts for identifying intervertebral discs with/without pain symptom and sore pain. METHODS Z-spectra data were collected from the lumbar discs of 26 patients with non-specific chronic low bck pain (CLBP) and 21 asymptomatic controls (AC) with a chemical exchange saturation transfer (CEST). Data were fitted to quantify the CEST effects from glycosaminoglycan, amide proton transfer (APT), nuclear Overhauser enhancement (NOE), semi-solid magnetization transfer contrast effects, and the direct saturation of water. Multiparametric maps were computed from the fitted peak amplitudes, and the average values were calculated from all five lumber discs. Those parameters were compared between the CLBP and AC groups and between the subgroups with and without (Nsore) sore pain. RESULTS The discs in symptomatic patients have lower water content, collagen-bound water and collagen than the discs in AC (P < 0.05). Additionally, Z-sepctral MRI indicated that the discs in the sore subgroup had less water, collagen-bound water and collagen, and likely lower pH compared to the Nsore subgroup (P < 0.05). Lower pH as measured with reduced APT and NOE effects may be an important pathological factor causing sore pain of the back. CONCLUSION Z-spectral MRI with its multiparametric metabolic and microenvironmental contrasts has been demonstrated to identify discs with and without pain symptom or sore pain, providing more important information of CLBP.
Collapse
Affiliation(s)
- Li Li
- Radiological Department, Tongji Hospital, Tongji Medical College, HUST, Wuhan, 430030, Hubei, People's Republic of China
- Departments of Radiology, Department of Bioengineering, and the Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA
| | - Zhiguo Zhou
- Department of Orthopedics, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, HUST, Wuhan, 430030, Hubei, People's Republic of China
| | - Wei Xiong
- Department of Orthopedics, Tongji Hospital, Tongji Medical College, HUST, Wuhan, 430030, Hubei, People's Republic of China
| | - Jicheng Fang
- Radiological Department, Tongji Hospital, Tongji Medical College, HUST, Wuhan, 430030, Hubei, People's Republic of China
| | - Alessandro Scotti
- Departments of Radiology, Department of Bioengineering, and the Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA
| | - Mehran Shaghaghi
- Departments of Radiology, Department of Bioengineering, and the Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA
| | - WenZhen Zhu
- Radiological Department, Tongji Hospital, Tongji Medical College, HUST, Wuhan, 430030, Hubei, People's Republic of China.
| | - Kejia Cai
- Departments of Radiology, Department of Bioengineering, and the Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
69
|
Zhang XY, Zhai Y, Jin Z, Li C, Sun PZ, Wu Y. Preliminary demonstration of in vivo quasi-steady-state CEST postprocessing-Correction of saturation time and relaxation delay for robust quantification of tumor MT and APT effects. Magn Reson Med 2021; 86:943-953. [PMID: 33723890 DOI: 10.1002/mrm.28764] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 01/26/2021] [Accepted: 02/15/2021] [Indexed: 12/16/2022]
Abstract
PURPOSE Chemical exchange saturation transfer (CEST) MRI is versatile for measuring the dilute labile protons and microenvironment properties. However, the use of insufficiently long RF saturation duration (Ts) and relaxation delay (Td) may underestimate the CEST measurement. This study proposed a quasi-steady-state (QUASS) CEST analysis for robust CEST quantification. METHODS The CEST signal evolution was modeled as a function of the longitudinal relaxation rate during Td and spin-lock relaxation rate during Ts, from which the QUASS-CEST effect is derived. Numerical simulation and in vivo rat glioma MRI experiments were conducted at 11.7 T to compare the apparent and QUASS-CEST results obtained under different Ts/Td of 2 seconds/2 seconds and 4 seconds/4 seconds. Magnetization transfer and amide proton transfer effects were resolved using a multipool Lorentzian fitting and evaluated in contralateral normal tissue and tumor regions. RESULTS The simulation showed the dependence of the apparent CEST effect on Ts and Td, and such reliance was mitigated with the QUASS algorithm. Animal experiment results showed that the apparent magnetization transfer and amide proton transfer effects and their contrast between contralateral normal tissue and tumor regions increased substantially with Ts and Td. In comparison, the QUASS magnetization transfer and amide proton transfer effects and their difference between contralateral normal tissue and tumor exhibited little dependence on Ts and Td. In addition, the apparent magnetization transfer and amide proton transfer were significantly smaller than the corresponding QUASS indices (P < .05). CONCLUSION The QUASS-CEST algorithm enables robust CEST quantification and offers a straightforward approach to standardize CEST experiments.
Collapse
Affiliation(s)
- Xiao-Yong Zhang
- Institute of Science and Technology for Brain-Inspired Intelligence, Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence, Ministry of Education, Fudan University, Shanghai, China
| | - Yuting Zhai
- Institute of Science and Technology for Brain-Inspired Intelligence, Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence, Ministry of Education, Fudan University, Shanghai, China
| | - Ziyi Jin
- Key Laboratory of Smart Drug Delivery, Ministry of Education, School of Pharmacy, Fudan University, Shanghai, China.,Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China
| | - Cong Li
- Key Laboratory of Smart Drug Delivery, Ministry of Education, School of Pharmacy, Fudan University, Shanghai, China.,Department of Neurosurgery, Huashan Hospital, Fudan University, Shanghai, China
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia, USA.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| |
Collapse
|
70
|
Sun PZ. Quasi-steady-state CEST (QUASS CEST) solution improves the accuracy of CEST quantification: QUASS CEST MRI-based omega plot analysis. Magn Reson Med 2021; 86:765-776. [PMID: 33749052 DOI: 10.1002/mrm.28744] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Revised: 01/27/2021] [Accepted: 01/31/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE CEST MRI omega plot quantifies the labile proton fraction ratio (fr ) and exchange rate (ksw ), yet it assumes long RF saturation time (Ts) and relaxation delay (Td). Our study aimed to test if a quasi-steady-state (QUASS) CEST analysis that accounts for the effect of finite Ts and Td could improve the accuracy of CEST MRI quantification. METHODS We modeled the MRI signal evolution using a typical CEST EPI sequence. The signal relaxes toward its thermal equilibrium following the bulk water relaxation rate during Td, and then toward its CEST steady state following the spin-lock relaxation rate during Ts from which the QUASS CEST effect is derived. Both fr and ksw were solved from simulated conventional apparent CEST and QUASS CEST MRI. We also performed MRI experiments from a Cr-gel phantom under serially varied Ts and Td times from 1.5 to 7.5 s. RESULTS Simulation showed that, although ksw could be slightly overestimated (3%-15%) for the range of Ts and Td, fr could be substantially underestimated by as much as 67%. In contrast, the QUASS solution provided accurate ksw and fr determination within 2%. The CEST MRI experiments confirmed that the QUASS solution enabled robust quantification of ksw and fr , superior over the omega plot analysis based on the conventional apparent CEST MRI measurements. CONCLUSIONS The QUASS CEST MRI algorithm corrects the effect of finite Ts and Td times on CEST measurements, thereby allowing robust and accurate CEST quantification.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia, USA.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
71
|
Dai Z, Kalra S, Mah D, Seres P, Sun H, Wu R, Wilman AH. Amide signal intensities may be reduced in the motor cortex and the corticospinal tract of ALS patients. Eur Radiol 2021; 31:1401-1409. [PMID: 32909054 DOI: 10.1007/s00330-020-07243-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Revised: 07/21/2020] [Accepted: 08/28/2020] [Indexed: 02/05/2023]
Abstract
OBJECTIVES The aim of the study is to assess amide concentration changes in ALS patients compared with healthy controls by using quantitative amide proton transfer (APT) and multiparameter magnetic resonance imaging, and testing its correlation with clinical scores. METHODS Sixteen ALS patients and sixteen healthy controls were recruited as part of the Canadian ALS Neuroimaging Consortium, and multimodal magnetic resonance imaging was performed at 3 T, including APT and diffusion imaging. Lorentz fitting was used to quantify the amide effect. Clinical disability was evaluated using the revised ALS functional rating scale (ALSFRS-R), and its correlation with image characteristics was assessed. The diagnostic performance of different imaging parameters was evaluated with receiver operating characteristic analysis. RESULTS Our results showed that the amide peak was significantly different between the motor cortex and other gray matter territories within the brain of ALS patients (p < 0.001). Compared with controls, amide signal intensities in ALS were significantly reduced in the motor cortex (p < 0.001) and corticospinal tract (p = 0.046), while abnormalities were not detected using routine imaging methods. There was no significant correlation between amide and ALSFRS-R score. The diagnostic accuracy of the amide peak was superior to that of diffusion imaging. CONCLUSIONS This study demonstrated changes of amide signal intensities in the motor cortex and corticospinal tract of ALS patients. KEY POINTS • The neurodegenerative disease amyotrophic lateral sclerosis (ALS) has a lack of objective imaging indicators for diagnosis and assessment. • Analysis of amide proton transfer imaging revealed changes in the motor cortex and corticospinal tract of ALS patients that were not visible on standard magnetic resonance imaging. • The diagnostic accuracy of the amide peak was superior to that of diffusion imaging.
Collapse
Affiliation(s)
- Zhuozhi Dai
- Department of Radiology, 2nd Affiliated Hospital of Shantou University Medical College, Shantou, 515041, Guangdong, China
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, T6G 2V2, Canada
| | - Sanjay Kalra
- Department of Medicine (Neurology), University of Alberta, Edmonton, Alberta, T6G 2S2, Canada
| | - Dennell Mah
- Department of Medicine (Neurology), University of Alberta, Edmonton, Alberta, T6G 2S2, Canada
| | - Peter Seres
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, T6G 2V2, Canada
| | - Hongfu Sun
- School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, Queensland, 4072, Australia
| | - Renhua Wu
- Department of Radiology, 2nd Affiliated Hospital of Shantou University Medical College, Shantou, 515041, Guangdong, China.
| | - Alan H Wilman
- Department of Biomedical Engineering, University of Alberta, Edmonton, Alberta, T6G 2V2, Canada.
| |
Collapse
|
72
|
Rivlin M, Navon G. Molecular imaging of cancer by glucosamine chemical exchange saturation transfer MRI: A preclinical study. NMR IN BIOMEDICINE 2021; 34:e4431. [PMID: 33103831 DOI: 10.1002/nbm.4431] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/23/2020] [Accepted: 09/23/2020] [Indexed: 06/11/2023]
Abstract
Glucosamine (GlcN) was recently proposed as an agent with an excellent safety profile to detect cancer with the chemical exchange saturation transfer (CEST) MRI technique. Translation of the GlcN CEST method to the clinical application requires evaluation of its sensitivity to the different frequency regions of irradiation. Hence, imaging of the GlcN signal was established for the full Z spectra recorded following GlcN administration to mice bearing implanted 4T1 breast tumors. Significant CEST effects were observed at around 1.5, 3.6 and -3.4 ppm, corresponding to the hydroxyl, amine/amide exchangeable protons and for the Nuclear Overhauser Enhancement (NOE), respectively. The sources of the observed CEST effects were investigated by identifying the GlcN metabolic products as observed by 13 C NMR spectroscopy studies of extracts from the same tumor model following treatment with [UL-13 C] -GlcN·HCl. The CEST contribution can be attributed to several phosphorylated products of GlcN, including uridine diphosphate-N-acetylglucosamine (UDP-GlcNAc), which is a substrate for the O-linked and N-linked glycosylated proteins that may be associated with the increase of the NOE signal. The observation of a significant amount of lactate among the metabolic products hints at acidification as one of the sources of the enhanced CEST effect of GlcN. The proposed method may offer a new approach for clinical molecular imaging that enables the detection of metabolically active tumors and may play a role in other diseases.
Collapse
Affiliation(s)
- Michal Rivlin
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| | - Gil Navon
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
73
|
Sun PZ. Quasi-steady state chemical exchange saturation transfer (QUASS CEST) analysis-correction of the finite relaxation delay and saturation time for robust CEST measurement. Magn Reson Med 2021; 85:3281-3289. [PMID: 33486816 DOI: 10.1002/mrm.28653] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Revised: 11/28/2020] [Accepted: 11/30/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE CEST provides a MR contrast mechanism sensitizing to the exchange between dilute labile and bulk water protons. However, the CEST effect depends on the RF saturation duration and relaxation delay, which need to be long to reach its steady state. Our study aims to estimate the QUAsi-Steady State (QUASS) CEST signal from experiments with shorter saturation and relaxation delay times. METHODS The evolution of the CEST signal was modeled as a function of the bulk water longitudinal relaxation rate during the relaxation delay (Td) and spin-lock relaxation rate during the RF saturation (Ts), from which the QUASS CEST effect is solved. Numeric simulations were programmed to compare the apparent CEST and QUASS CEST effects as a function of Ts and Td times. We also performed CEST MRI experiments from a creatine-gel pH phantom under serially varied Ts and Td times. RESULTS The numeric simulation showed that although the apparent CEST effect depends on Td and Ts, the QUASS CEST solution has little dependence. Phantom results showed that the routine CEST pH contrast could be described by a nonlinear regression model (ie, Δ C E S T R = Δ C E S T R eq app 1 - e - R 1 ρ app · t ). We had Δ C E S T R eq app = 3.90 ± 0.03 % (P < 5e-8) and R 1 ρ app = 0.62 ± 0.02 s - 1 (P < 5e-6). For the QUASS CEST analysis, we modeled the pH contrast as Δ C E S T R = Δ C E S T R eq QUASS + s · t , using a linear regression model. We had Δ C E S T R eq QUASS = 3.63 ± 0.01 % (P < 5e-9) and s = - 0.02 ± 0.00 % / s (P < 0.01), the slope of which is minimal. CONCLUSIONS The QUASS CEST algorithm provides a post-processing solution that facilitates robust CEST measurement.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia, USA.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
74
|
Kim H, Wu Y, Villano D, Longo DL, McMahon MT, Sun PZ. Analysis Protocol for the Quantification of Renal pH Using Chemical Exchange Saturation Transfer (CEST) MRI. Methods Mol Biol 2021; 2216:667-688. [PMID: 33476030 PMCID: PMC9703203 DOI: 10.1007/978-1-0716-0978-1_40] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
The kidney plays a major role in maintaining body pH homeostasis. Renal pH, in particular, changes immediately following injuries such as intoxication and ischemia, making pH an early biomarker for kidney injury before the symptom onset and complementary to well-established laboratory tests. Because of this, it is imperative to develop minimally invasive renal pH imaging exams and test pH as a new diagnostic biomarker in animal models of kidney injury before clinical translation. Briefly, iodinated contrast agents approved by the US Food and Drug Administration (FDA) for computed tomography (CT) have demonstrated promise as novel chemical exchange saturation transfer (CEST) MRI agents for pH-sensitive imaging. The generalized ratiometric iopamidol CEST MRI analysis enables concentration-independent pH measurement, which simplifies in vivo renal pH mapping. This chapter describes quantitative CEST MRI analysis for preclinical renal pH mapping, and their application in rodents, including normal conditions and acute kidney injury.This publication is based upon work from the COST Action PARENCHIMA, a community-driven network funded by the European Cooperation in Science and Technology (COST) program of the European Union, which aims to improve the reproducibility and standardization of renal MRI biomarkers. This analysis protocol chapter is complemented by two separate chapters describing the basic concepts and experimental procedure.
Collapse
Affiliation(s)
- Hahnsung Kim
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA
| | - Yin Wu
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Daisy Villano
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| | - Michael T McMahon
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Phillip Zhe Sun
- Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA.
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, USA.
| |
Collapse
|
75
|
Tang X, Zhang H, Zhou J, Kang H, Yang S, Cui H, Peng Y. Brain development in children with developmental delay using amide proton transfer-weighted imaging and magnetization transfer imaging. Pediatr Investig 2020; 4:250-256. [PMID: 33376952 PMCID: PMC7768295 DOI: 10.1002/ped4.12237] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 06/02/2020] [Indexed: 11/09/2022] Open
Abstract
IMPORTANCE The process of brain development in children with developmental delay is not well known. Amide proton transfer-weighted (APTw) imaging is a novel molecular magnetic resonance imaging (MRI) technique that can noninvasively detect cytosolic endogenous mobile proteins and peptides involved in the myelination process, and may be useful for providing insights into brain development. OBJECTIVE To assess the contribution of amide proton transfer-weighted (APTw) imaging and magnetization transfer (MT) imaging to the evaluation of children with developmental delay (DD). METHODS Fifty-one patients with DD were recruited to this study. The patients were divided into two groups according to the state of myelination assessed on conventional magnetic resonance imaging (MRI). Thirty patients (10 girls, 20 boys; age range: 1-8 months; median age: 4 months) in group A showed delayed myelination on MRI, while 21 patients (3 girls, 18 boys; age range: 12-36months; median age: 25months) in group B showed normal myelination on MRI. Fifty-one age- and sex-matched children with normal developmental quotient (DQ) and normal MRI appearance were recruited as normal controls. Three-slice APTw/MT axial imaging was performed at the level of the centrum semiovale, the basal ganglia and the pons. Quantitative data of the MT ratio (MTR) and APTw were analyzed for multiple brain regions. Independent-sample t-tests were used to compare differences in APTw and MTR signals between the two DD groups and normal controls. Analysis of Covariance was conducted to correct the statistical results. The level of statistical significance was set to P < 0.05. RESULTS For group A, the MTR values were lower in all regions (P = 0.004-0.033) compared with the normal controls, while the APTw values were higher in the pons, middle cerebellar peduncle, corpus callosum, frontal white matter, occipital white matter and centrum semiovale (P = 0.004-0.040 ). For Group B, the MTR values were slightly reduced, and the APTw values were slightly increased compared with the normal controls, but the differences were not statistically significant (P > 0.05). INTERPRETATION For DD patients showing signs of delayed myelination on MRI, MTR and APTw imaging can help to diagnose myelination delay by quantifying semi-solid macromolecules and cytosolic endogenous mobile proteins and peptides at a molecular level, providing a new method for comprehensive evaluation of DD. For DD patients with normal myelination on MRI, the clinical values of MTR and APTw imaging remain to be explored.
Collapse
Affiliation(s)
- Xiaolu Tang
- Imaging CenterBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Hong Zhang
- Imaging CenterBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Jinyuan Zhou
- Division of MR ResearchDepartment of RadiologyJohns Hopkins UniversityBaltimoreMDUSA
| | - Huiying Kang
- Imaging CenterBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Shuangfeng Yang
- Imaging CenterBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Haijing Cui
- Rehabilitation DepartmentBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| | - Yun Peng
- Imaging CenterBeijing Children's HospitalCapital Medical UniversityNational Center for Children's HealthBeijingChina
| |
Collapse
|
76
|
Chen L, Cao S, Koehler RC, van Zijl PCM, Xu J. High-sensitivity CEST mapping using a spatiotemporal correlation-enhanced method. Magn Reson Med 2020; 84:3342-3350. [PMID: 32597519 PMCID: PMC7722217 DOI: 10.1002/mrm.28380] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 05/01/2020] [Accepted: 05/23/2020] [Indexed: 01/29/2023]
Abstract
PURPOSE To obtain high-sensitivity CEST maps by exploiting the spatiotemporal correlation between CEST images. METHODS A postprocessing method accomplished by multilinear singular value decomposition (MLSVD) was used to enhance the CEST SNR by exploiting the correlation between the Z-spectrum for each voxel and the low-rank property of the overall CEST data. The performance of this method was evaluated using CrCEST in ischemic mouse brain at 11.7 tesla. Then, MLSVD CEST was applied to obtain Cr, amide, and amine CEST maps of the ischemic mouse brain to demonstrate its general applications. RESULTS Complex-valued Gaussian noise was added to CEST k-space data to mimic a low SNR situation. MLSVD CEST analysis was able to suppress the noise, recover the degraded CEST peak, and provide better CrCEST quality compared to the smoothing and singular value decomposition (SVD)-based denoising methods. High-resolution Cr, amide, and amine CEST maps of an ischemic stroke using MLSVD CEST suggest that CrCEST is also a sensitive pH mapping method, and a wide range of pH changes can be detected by combing CrCEST with amine CEST at high magnetic fields. CONCLUSION MLSVD CEST provides a simple and efficient way to improve the SNR of CEST images.
Collapse
Affiliation(s)
- Lin Chen
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA,Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA,Corresponding Author: Lin Chen, Ph.D., Kennedy Krieger Institute, Johns Hopkins University School of Medicine, 707 N. Broadway, Baltimore, MD, 21205,
| | - Suyi Cao
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Raymond C. Koehler
- Department of Anesthesiology and Critical Care Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Peter C. M. van Zijl
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA,Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, MD, USA,Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| |
Collapse
|
77
|
Xue M, Sampath J, Gebhart RN, Haugen HJ, Lyngstadaas SP, Pfaendtner J, Drobny G. Studies of Dynamic Binding of Amino Acids to TiO 2 Nanoparticle Surfaces by Solution NMR and Molecular Dynamics Simulations. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:10341-10350. [PMID: 32693593 PMCID: PMC8098425 DOI: 10.1021/acs.langmuir.0c01256] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Adsorption of biomolecules onto material surfaces involves a potentially complex mechanism where molecular species interact to varying degrees with a heterogeneous material surface. Surface adsorption studies by atomic force microscopy, sum frequency generation spectroscopy, and solid-state NMR detect the structures and interactions of biomolecular species that are bound to material surfaces, which, in the absence of a solid-liquid interface, do not exchange rapidly between surface-bound forms and free molecular species in bulk solution. Solution NMR has the potential to complement these techniques by detecting and studying transiently bound biomolecules at the liquid-solid interface. Herein, we show that dark-state exchange saturation transfer (DEST) NMR experiments on gel-stabilized TiO2 nanoparticle (NP) samples detect several forms of biomolecular adsorption onto titanium(IV) oxide surfaces. Specifically, we use the DEST approach to study the interaction of amino acids arginine (Arg), lysine (Lys), leucine (Leu), alanine (Ala), and aspartic acid (Asp) with TiO2 rutile NP surfaces. Whereas Leu, Ala, and Asp display only a single weakly interacting form in the presence of TiO2 NPs, Arg and Lys displayed at least two distinct bound forms: a species that is surface bound and retains a degree of reorientational motion and a second more tightly bound form characterized by broadened DEST profiles upon the addition of TiO2 NPs. Molecular dynamics simulations indicate different surface bound states for both Lys and Arg depending on the degree of TiO2 surface hydroxylation but only a single bound state for Asp regardless of the degree of surface hydroxylation, in agreement with results obtained from the analysis of DEST profiles.
Collapse
Affiliation(s)
- Mengjun Xue
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195, United States
| | - Janani Sampath
- Department of Chemical Engineering, University of Washington, Box 351700, Seattle, Washington 98195, United States
| | - Rachel N Gebhart
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195, United States
| | - Havard J Haugen
- Department for Biomaterials, Faculty for Odontology, University of Oslo, P.O. Box 1109, Blindern, Oslo NO-0317, Norway
| | - S Petter Lyngstadaas
- Department for Biomaterials, Faculty for Odontology, University of Oslo, P.O. Box 1109, Blindern, Oslo NO-0317, Norway
| | - Jim Pfaendtner
- Department of Chemical Engineering, University of Washington, Box 351700, Seattle, Washington 98195, United States
| | - Gary Drobny
- Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195, United States
| |
Collapse
|
78
|
Novel proton exchange rate MRI presents unique contrast in brains of ischemic stroke patients. J Neurosci Methods 2020; 346:108926. [PMID: 32896540 DOI: 10.1016/j.jneumeth.2020.108926] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Revised: 08/23/2020] [Accepted: 08/31/2020] [Indexed: 01/03/2023]
Abstract
BACKGROUND To map and quantify the proton exchange rate (kex) of brain tissues using improved omega plots in ischemic stroke patients and to investigate whether kex can serve as a potential endogenous surrogate imaging biomarker for detecting the metabolic state and the pathologic changes due to ischemic stroke. NEW METHOD Three sets of Z-spectra were acquired from seventeen ischemic stroke patients using a spin echo-echo planar imaging sequence with pre-saturation chemical exchange saturation transfer (CEST) pulse at B1 of 1.5, 2.5, and 3.5 μT, respectively. Pixel-wise kex was calculated from improved omega plot of water direct saturation (DS)-removed Z-spectral signals. RESULTS The derived kex maps can differentiate infarcts from contralateral normal brain tissues with significantly increased signal (893 ± 52 s-1vs. 739 ± 34 s-1, P < 0.001). COMPARISON WITH EXISTING METHOD(S) The kex maps were found to be different from conventional contrasts from diffusion-weighted imaging (DWI), CEST, and semi-solid magnetization transfer (MT) MRI. In brief, kex MRI showed larger lesion areas than DWI with different degrees and different lesion contrast compared to CEST and MT. CONCLUSIONS In this preliminary translational research, the kex MRI based on DS-removed omega plots has been demonstrated for in vivo imaging of clinical ischemic stroke patients. As a noninvasive and unique MRI contrast, kex MRI at 3 T may serve as a potential surrogate imaging biomarker for the metabolic changes of stroke and help for monitoring the evolution and the treatment of stroke.
Collapse
|
79
|
Lee H, Choi SH, Sohn CH, Kim SG, Lee J, Park J. Rapid three-dimensional steady-state chemical exchange saturation transfer magnetic resonance imaging. Magn Reson Med 2020; 85:1209-1221. [PMID: 32851659 DOI: 10.1002/mrm.28487] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Revised: 07/11/2020] [Accepted: 07/30/2020] [Indexed: 02/05/2023]
Abstract
PURPOSE To make clinically feasible whole-brain chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) by enhancing imaging efficiency. METHODS A novel, whole-brain three-dimensional (3D) steady-state CEST MRI method was introduced by utilizing a time-efficient, fat-suppressed excitation followed by rapid, segmented 3D echo-planar-imaging with incoherent undersampling in k-ω space. Missing signals and CEST-specific spectral images were then jointly estimated directly from incomplete measurements using model-based reconstruction and robust spectral analysis. In vivo studies were performed at 3T both retrospectively (using a fully sampled reference) and prospectively to validate the effectiveness of the proposed method in patients with brain cancer. RESULTS In retrospective studies, the proposed method exhibits superior accuracies to existing methods in estimating images, z-spectra, and APTw relative to the reference. In prospective patient studies, compared with existing methods, the proposed method is statistically significantly different in contrast-to-noise ratio of the APTw contrast between tumor and normal appearing white matter (NAWM) and amide proton transfer weighted contrast (p < 0.05) while not being significantly different in signal-to-noise ratio in an NAWM region. CONCLUSIONS We successfully demonstrated that it is feasible to perform whole-brain CEST MRI roughly within 4 minutes for patients with brain cancer. It is expected that the proposed method widens clinical utilities of CEST MRI.
Collapse
Affiliation(s)
- Hoonjae Lee
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea
| | - Seung Hong Choi
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Chul-Ho Sohn
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Seong-Gi Kim
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea
| | - Joonyeol Lee
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea
| | - Jaeseok Park
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Biomedical Institute for Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| |
Collapse
|
80
|
Huang J, Han X, Chen L, Xu X, Xu J, Chan KWY. Relayed nuclear Overhauser enhancement imaging with magnetization transfer contrast suppression at 3 T. Magn Reson Med 2020; 85:254-267. [PMID: 32738080 DOI: 10.1002/mrm.28433] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2020] [Revised: 06/10/2020] [Accepted: 06/24/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE To develop a pulsed CEST magnetization-transfer method for rapidly acquiring relayed nuclear Overhauser enhancement (rNOE)-weighted images with magnetic transfer contrast (MTC) suppression at clinical field strength (3 T). METHODS Using a pulsed CEST magnetization-transfer method with low saturation powers (B1 ) and long mixing time (tmix ) to suppress contributions due to strong MTC from solid-like macromolecules, a low B1 also minimized direct water saturation. These MTC contributions were further reduced by subtracting the Z-spectral signals at two or three offsets by assuming that the residual MTC is a linear function between -3.5 ppm and -12.5 ppm. RESULTS Phantom studies of a lactic acid (Lac) solution mixed with cross-linked bovine serum albumin show that strong MTC interference has a significant impact on the optimum B1 for detecting rNOEs, due to lactate binding. The MTC could be effectively suppressed using a pulse train with a B1 of 0.8 μT, a pulse duration (tp ) of 40 ms, a tmix of 60 ms, and a pulse number (N) of 30, while rNOE signal was well maintained. As a proof of concept, we applied the method in mouse brain with injected hydrogel and a cell-hydrogel phantom. Results showed that rNOE-weighted images could provide good contrast between brain/cell and hydrogel. CONCLUSION The developed pulsed CEST magnetization-transfer method can achieve MTC suppression while preserving most of the rNOE signal at 3 T, which indicates the potential for translation of this technique to clinical applications related to mobile proteins/lipids change.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Xiongqi Han
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Lin Chen
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Xiang Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Jiadi Xu
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China.,Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,City University of Hong Kong Shenzhen Research Institute, Shenzhen, China
| |
Collapse
|
81
|
Guo C, Wu J, Rosenberg JT, Roussel T, Cai S, Cai C. Fast chemical exchange saturation transfer imaging based on PROPELLER acquisition and deep neural network reconstruction. Magn Reson Med 2020; 84:3192-3205. [PMID: 32602965 DOI: 10.1002/mrm.28376] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 05/21/2020] [Accepted: 05/23/2020] [Indexed: 12/14/2022]
Abstract
PURPOSE To develop a method for fast chemical exchange saturation transfer (CEST) imaging. METHODS The periodically rotated overlapping parallel lines enhanced reconstruction (PROPELLER) sampling scheme was introduced to shorten the acquisition time. Deep neural network was employed to reconstruct CEST contrast images. Numerical simulation and experiments on a creatine phantom, hen egg, and in vivo tumor rat brain were performed to test the feasibility of this method. RESULTS The results from numerical simulation and experiments show that there is no significant difference between reference images and CEST-PROPELLER reconstructed images under an acceleration factor of 8. CONCLUSION Although the deep neural network is trained entirely on synthesized data, it works well on reconstructing experimental data. The proof of concept study demonstrates that the combination of the PROPELLER sampling scheme and the deep neural network enables considerable acceleration of saturated image acquisition and may find applications in CEST MRI.
Collapse
Affiliation(s)
- Chenlu Guo
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Jian Wu
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Jens T Rosenberg
- The National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Tangi Roussel
- The National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, USA
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Congbo Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| |
Collapse
|
82
|
Amide Proton Transfer-Weighted (APTw) Imaging of Intracranial Infection in Children: Initial Experience and Comparison with Gadolinium-Enhanced T1-Weighted Imaging. BIOMED RESEARCH INTERNATIONAL 2020; 2020:6418343. [PMID: 32509865 PMCID: PMC7251435 DOI: 10.1155/2020/6418343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2019] [Revised: 03/21/2020] [Accepted: 04/25/2020] [Indexed: 12/05/2022]
Abstract
Purpose To evaluate the performance of amide proton transfer-weighted (APTw) imaging against the reference standard of gadolinium-enhanced T1-weighted imaging (Gd-T1w) in children with intracranial infection. Materials and Methods Twenty-eight pediatric patients (15 males and 13 females; age range 1-163 months) with intracranial infection were recruited in this study. 2D APTw imaging and conventional MR sequences were conducted using a 3 T MRI scanner. Kappa (κ) statistics and the McNemar test were performed to determine whether the hyperintensity on APTw was related to the enhancement on Gd-T1w. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of APTw imaging to predict lesion enhancement were calculated. Result In twelve patients with brain abscesses, the enhancing rim of the abscesses on the Gd-T1w images was consistently hyperintense on the APTw images. In eight patients with viral encephalitis, three showed slight spotted gadolinium enhancement, while the APTw image also showed a slight spotted high signal. Five of these patients showed no enhancement on Gd-T1w and isointensity on the APTw image. In eleven patients with meningitis, increased APTw signal intensities were clearly visible in gadolinium-enhancing meninges. Sixty infectious lesions (71%) showed enhancement on Gd-T1w images. The sensitivity and specificity of APTw were 93.3% (56/60) and 91.7% (22/24). APTw demonstrated excellent agreement (κ = 0.83) with Gd-T1w, with no significant difference (P = 0.69) in detection of infectious lesions. Conclusions These initial data show that APTw MRI is a noninvasive technique for the detection and characterization of intracranial infectious lesions. APTw MRI enabled similar detection of infectious lesions to Gd-T1w and may provide an injection-free means of evaluation of intracranial infection.
Collapse
|
83
|
Debnath A, Gupta RK, Singh A. Evaluating the Role of Amide Proton Transfer (APT)-Weighted Contrast, Optimized for Normalization and Region of Interest Selection, in Differentiation of Neoplastic and Infective Mass Lesions on 3T MRI. Mol Imaging Biol 2020; 22:384-396. [PMID: 31228076 PMCID: PMC7109008 DOI: 10.1007/s11307-019-01382-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
PURPOSE To evaluate the role of amide proton transfer-weighted (APT-w) magnetic resonance imaging (MRI) in differentiating neoplastic and infective mass lesions using different contrast normalizations, region of interest (ROI) selection, and histogram analysis. PROCEDURES Retrospective study included 32 treatment-naive patients having intracranial mass lesions (ICMLs): low-grade glioma (LGG) = 14, high-grade glioma (HGG) = 10, and infective mass lesions = 8. APT-w MRI images were acquired along with conventional MRI images at 3 T. APT-w contrast, corrected for B0-field inhomogeneity, was computed and optimized with respect to different types of normalizations. Different ROIs on lesion region were selected followed by ROI analysis and histogram analysis. Statistical analysis was performed using Shapiro-Wilk's test, t tests, ANOVA with Tukey's post hoc test, and receiver operation characteristic (ROC) analysis. RESULTS ICMLs showed significantly (p < 0.01) higher APT-w contrast in lesion compared with contralateral side. There was a substantial overlap between mean APT-w contrast of neoplastic and infective mass lesions as well as among different groups of ICMLs irrespective of ROI selection and normalizations. APT-w contrast (using type 4 normalization: normalized with reference signal at negative offset frequency and APT-w contrast in normal-appearing white matter) reduced variability of APT-w contrast across different subjects, and overlap was less compared with other types of normalizations. There was a significant difference (p < 0.05) between neoplastic and infective mass lesions using t test for different histogram parameters of type 4 normalized APT-w contrast. ANOVA with post hoc showed significant difference (p < 0.05) for different histogram parameters of APT-w contrast (Type 4 normalization) between LGG and HGG, LGG, and infective mass lesion. Histogram parameters such as standard deviation, mean of top percentiles, and median provided improved differentiation between neoplastic and infective mass lesions compared with mean APT-w contrast. A greater number of histogram parameters of type 4 normalized APT-w contrast corresponding to active lesion region can significantly differentiate between ICMLs than other types of normalizations and ROIs. CONCLUSIONS APT-w contrast using type 4 normalization and active lesion region (ROI-2) should be used for studying APT. APT-MRI should be combined with other MRI techniques to further improve the differential diagnosis of ICMLs.
Collapse
Affiliation(s)
- Ayan Debnath
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, Block II, Room No. 299, New Delhi, 110016, India
| | | | - Anup Singh
- Centre for Biomedical Engineering, Indian Institute of Technology Delhi, Block II, Room No. 299, New Delhi, 110016, India.
- Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi, India.
| |
Collapse
|
84
|
Zhang Z, Zhang C, Yao J, Gao F, Gong T, Jiang S, Chen W, Zhou J, Wang G. Amide proton transfer-weighted magnetic resonance imaging of human brain aging at 3 Tesla. Quant Imaging Med Surg 2020; 10:727-742. [PMID: 32269932 DOI: 10.21037/qims.2020.02.22] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background Amide proton transfer-weighted (APTw) imaging has been revealed to hold great potential in the diagnosis of several brain diseases. The purpose of this proof-of-concept study was to evaluate the feasibility and value of APTw magnetic resonance imaging (MRI) in characterizing normal brain aging. Methods A total of 106 healthy subjects were recruited and scanned at 3.0 Tesla, with APTw and conventional magnetization transfer (MT) sequences. Quantitative image analyses were performed in 12 regions of interest (ROIs) for each subject. The APTw or MT ratio (MTR) signal differences among five age groups (young, mature, middle-aged, young-old, and middle-old) were assessed using the one-way analysis of variance, with the Benjamini-Hochberg correction for multiple comparisons. The relationship between APTw and MTR signals and the age dependencies of APTw and MTR signals were assessed using the Pearson correlation and non-linear regression. Results There were no significant differences between the APTw or MTR values for males and females in any of the 12 ROIs analyzed. Among the five age groups, there were significant differences in the three white matter regions in the temporal, occipital, and frontal lobes. Overall, the mean APTw values in the older group were higher than those in the younger group. Positive correlations were observed in relation to age in most brain regions, including four with significant positive correlations (r=0.2065-0.4182) and five with increasing trends. As a comparison, the mean MTR values did not appear to be significantly different among the five age groups. In addition, the mean APTw and MTR values revealed significant positive correlations in 10 ROIs (r=0.2214-0.7269) and a significant negative correlation in one ROI (entorhinal cortex, r=-0.2141). Conclusions Our early results show that the APTw signal can be used as a promising and complementary imaging biomarker with which normal brain aging can be evaluated at the molecular level.
Collapse
Affiliation(s)
- Zewen Zhang
- Department of MR, Shandong Medical Imaging Research Institute, Shandong University, Jinan 250021, China.,Division of MR Research, Department of Radiology, Johns Hopkins University, Maryland, USA
| | - Caiqing Zhang
- Department of Respiratory Medicine, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan 250014, China
| | - Jian Yao
- Department of MR, Shandong Medical Imaging Research Institute, Shandong University, Jinan 250021, China
| | - Fei Gao
- Department of MR, Shandong Medical Imaging Research Institute, Shandong University, Jinan 250021, China
| | - Tao Gong
- Department of MR, Shandong Medical Imaging Research Institute, Shandong University, Jinan 250021, China
| | - Shanshan Jiang
- Division of MR Research, Department of Radiology, Johns Hopkins University, Maryland, USA
| | - Weibo Chen
- Philips Healthcare, Shanghai 200072, China
| | - Jinyuan Zhou
- Division of MR Research, Department of Radiology, Johns Hopkins University, Maryland, USA
| | - Guangbin Wang
- Department of MR, Shandong Medical Imaging Research Institute, Shandong University, Jinan 250021, China
| |
Collapse
|
85
|
Ohki A, Saito S, Hirayama E, Takahashi Y, Ogawa Y, Tsuji M, Higuchi T, Fukuchi K. Comparison of Chemical Exchange Saturation Transfer Imaging with Diffusion-weighted Imaging and Magnetic Resonance Spectroscopy in a Rat Model of Hypoxic-ischemic Encephalopathy. Magn Reson Med Sci 2020; 19:359-365. [PMID: 32009063 PMCID: PMC7809148 DOI: 10.2463/mrms.mp.2019-0128] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Purpose: This study aimed to evaluate the effect of chemical exchange saturation transfer (CEST) on the ischemic regions in hypoxic-ischemic encephalopathy (HIE) in comparison with diffusion-weighted imaging (DWI) and magnetic resonance spectroscopy (MRS) using a 7T-MRI. Methods: We used neonatal rats (n = 8), aged 8 days, to clarify the progression of HIE. The rat model of HIE was developed by ligating and severing the left common carotid artery, followed by 45 minutes of recovery, and 60 minutes of hypoxia (8% O2/92% N2; 34°C). At 0–2 and 24 hours after the onset of HIE, CEST imaging, DWI, and MRS were performed with a 7T-MRI. The magnetization transfer ratio (MTR) asymmetry curves and four MTR asymmetry maps at 0.5, 1.0, 2.0, and 3.5 ppm were calculated using the CEST images. Fractional anisotropy (FA) and apparent diffusion coefficient (ADC) maps were calculated by DWI, and brain metabolites were assessed by MRS. Results: In the ischemic regions of neonatal rats, FA was significantly increased at 0–2 hours and decreased at 24 hours after the onset of HIE. ADC in the ipsilateral side was significantly lower than that of contralateral side. All rats with HIE showed hypointense areas on MTR asymmetry maps (2.0 and 3.5 ppm), that did not correspond with the hyperintense areas on DWI. In addition, a significant increase in lactate levels was observed at 0–2 and 24 hours after the onset of HIE. Conclusion: CEST MTR maps did not correspond with the hyperintense areas on DWI at 0–2 and 24 hours after the onset of HIE. The change of multi offset CEST signal may be primarily related to the brain metabolites and pH alterations, such as that caused by lactate, after the onset of HIE.
Collapse
Affiliation(s)
- Akiko Ohki
- Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine.,Department of Biomedical Imaging, National Cardiovascular and Cerebral Research Center
| | - Shigeyoshi Saito
- Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine.,Department of Biomedical Imaging, National Cardiovascular and Cerebral Research Center
| | - Eri Hirayama
- Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine
| | - Yusuke Takahashi
- Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine
| | - Yuko Ogawa
- Department of Regenerative Medicine Research, Foundation for Biomedical Research and Innovation at Kobe
| | - Masahiro Tsuji
- Department of Food and Nutrition, Kyoto Women's University
| | - Takahiro Higuchi
- Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine.,Comprehensive Heart Failure Center, University of Wurzburg.,Department of Nuclear Medicine, University of Wurzburg
| | - Kazuki Fukuchi
- Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University Graduate School of Medicine
| |
Collapse
|
86
|
Shaffer JJ, Mani M, Schmitz SL, Xu J, Owusu N, Wu D, Magnotta VA, Wemmie JA. Proton Exchange Magnetic Resonance Imaging: Current and Future Applications in Psychiatric Research. Front Psychiatry 2020; 11:532606. [PMID: 33192650 PMCID: PMC7542226 DOI: 10.3389/fpsyt.2020.532606] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 09/02/2020] [Indexed: 12/20/2022] Open
Abstract
Proton exchange provides a powerful contrast mechanism for magnetic resonance imaging (MRI). MRI techniques sensitive to proton exchange provide new opportunities to map, with high spatial and temporal resolution, compounds important for brain metabolism and function. Two such techniques, chemical exchange saturation transfer (CEST) and T1 relaxation in the rotating frame (T1ρ), are emerging as promising tools in the study of neurological and psychiatric illnesses to study brain metabolism. This review describes proton exchange for non-experts, highlights the current status of proton-exchange MRI, and presents advantages and drawbacks of these techniques compared to more traditional methods of imaging brain metabolism, including positron emission tomography (PET) and MR spectroscopy (MRS). Finally, this review highlights new frontiers for the use of CEST and T1ρ in brain research.
Collapse
Affiliation(s)
- Joseph J Shaffer
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Merry Mani
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Samantha L Schmitz
- Department of Psychiatry, University of Iowa, Iowa City, IA, United States
| | - Jia Xu
- Department of Radiology, University of Iowa, Iowa City, IA, United States
| | - Nana Owusu
- Department of Radiology, University of Iowa, Iowa City, IA, United States.,Pappajohn Biomedical Institute, University of Iowa, Iowa City, IA, United States.,Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
| | - Dee Wu
- Department of Radiology, University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Vincent A Magnotta
- Department of Radiology, University of Iowa, Iowa City, IA, United States.,Department of Psychiatry, University of Iowa, Iowa City, IA, United States.,Department of Biomedical Engineering, University of Iowa, Iowa City, IA, United States
| | - John A Wemmie
- Department of Psychiatry, University of Iowa, Iowa City, IA, United States.,Pappajohn Biomedical Institute, University of Iowa, Iowa City, IA, United States.,Department of Veterans Affairs Medical Center, Iowa City, IA, United States.,Department of Molecular Physiology and Biophysics, University of Iowa, Iowa City, IA, United States.,Department of Neurosurgery, University of Iowa, Iowa City, IA, United States
| |
Collapse
|
87
|
Singh A, Debnath A, Cai K, Bagga P, Haris M, Hariharan H, Reddy R. Evaluating the feasibility of creatine-weighted CEST MRI in human brain at 7 T using a Z-spectral fitting approach. NMR IN BIOMEDICINE 2019; 32:e4176. [PMID: 31608510 PMCID: PMC11463199 DOI: 10.1002/nbm.4176] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/01/2019] [Accepted: 08/02/2019] [Indexed: 06/10/2023]
Abstract
The current study aims to evaluate the feasibility of creatine (Cr) chemical exchange saturation transfer (CEST)-weighted MRI at 7 T in the human brain by optimizing the saturation pulse parameters and computing contrast using a Z-spectral fitting approach. The Cr-weighted (Cr-w) CEST contrast was computed from phantoms data. Simulations were carried out to obtain the optimum saturation parameters for Cr-w CEST with lower contribution from other brain metabolites. CEST-w images were acquired from the brains of four human subjects at different saturation parameters. The Cr-w CEST contrast was computed using both asymmetry analysis and Z-spectra fitting approaches (models 1 and 2, respectively) based on Lorentzian functions. For broad magnetization transfer (MT) effect, Gaussian and Super-Lorentzian line shapes were also evaluated. In the phantom study, the Cr-w CEST contrast showed a linear dependence on concentration in physiological range and a nonlinear dependence on saturation parameters. The in vivo Cr-w CEST map generated using asymmetry analysis from the brain represents mixed contrast with contribution from other metabolites as well and relayed nuclear Overhauser effect (rNOE). Simulations provided an estimate for the optimum range of saturation parameters to be used for acquiring brain CEST data. The optimum saturation parameters for Cr-w CEST to be used for brain data were around B1rms = 1.45 μT and duration = 2 seconds. The Z-spectral fitting approach enabled computation of individual components. This also resulted in mitigating the contribution from MT and rNOE to Cr-w CEST contrast, which is a major source of underestimation in asymmetry analysis. The proposed modified z-spectra fitting approach (model 2) is more stable to noise compared with model 1. Cr-w CEST contrast obtained using fitting was 6.98 ± 0.31% in gray matter and 5.45 ± 0.16% in white matter. Optimal saturation parameters reduced the contribution from other CEST effects to Cr-w CEST contrast, and the proposed Z-spectral fitting approach enabled computation of individual components in Z-spectra of the brain. Therefore, it is feasible to compute Cr-w CEST contrast with a lower contribution from other CEST and rNOE.
Collapse
Affiliation(s)
- Anup Singh
- CBME, Indian Institute of Technology Delhi, New Delhi, India
- Department of Biomedical Engineering, AIIMS, Delhi, India
| | - Ayan Debnath
- CBME, Indian Institute of Technology Delhi, New Delhi, India
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Kejia Cai
- Radiology, University of Illinois at Chicago, Chicago, Illinois
| | - Puneet Bagga
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Mohammad Haris
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
- Research Branch, Sidra Medical and Research Center, Doha, Qatar
| | - Hari Hariharan
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| | - Ravinder Reddy
- CMROI, Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
| |
Collapse
|
88
|
Chen L, Wei Z, Cai S, Li Y, Liu G, Lu H, Weiss RG, van Zijl PCM, Xu J. High-resolution creatine mapping of mouse brain at 11.7 T using non-steady-state chemical exchange saturation transfer. NMR IN BIOMEDICINE 2019; 32:e4168. [PMID: 31461196 DOI: 10.1002/nbm.4168] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2019] [Revised: 07/27/2019] [Accepted: 07/31/2019] [Indexed: 06/10/2023]
Abstract
The current study aims to optimize the acquisition scheme for the creatine chemical exchange saturation transfer weighted (CrCESTw) signal on mouse brain at 11.7 T, in which a strong magnetization transfer contrast (MTC) is present, and to further develop the polynomial and Lorentzian line-shape fitting (PLOF) method for quantifying CrCESTw signal with a non-steady-state (NSS) acquisition scheme. Studies on a Cr phantom with cross-linked bovine serum albumin (BSA) as well as on mouse brain demonstrated that the maximum CrCESTw signal was reached with a short saturation time determined by the rotating frame relaxation time of the MTC pool instead of the steady-state saturation. The saturation power for the maximal signal was around 1-1.5 μT for Cr with 20% cross-linked BSA and in vivo applications, but 2 μT was found to be most practical for signal stability. For the CrCEST acquisition with strong MTC interference, the optimal saturation power and length are completely different from those on Cr solution alone. This observation could be explained well using R1ρ theory by incorporating the strong MTC pool. Finally, a high-resolution Cr map was obtained on mouse brain using the PLOF method with the NSS CEST acquisition and a cryogenic coil. The Cr map obtained by CEST showed homogenous intensity across the mouse brain except for regions with cerebrospinal fluid.
Collapse
Affiliation(s)
- Lin Chen
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Zhiliang Wei
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Yuguo Li
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Guanshu Liu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Hanzhang Lu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Robert G Weiss
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Peter C M van Zijl
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| | - Jiadi Xu
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
- F. M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Research Institute, Baltimore, Maryland, USA
| |
Collapse
|
89
|
Heo HY, Xu X, Jiang S, Zhao Y, Keupp J, Redmond KJ, Laterra J, van Zijl PC, Zhou J. Prospective acceleration of parallel RF transmission-based 3D chemical exchange saturation transfer imaging with compressed sensing. Magn Reson Med 2019; 82:1812-1821. [PMID: 31209938 PMCID: PMC6660350 DOI: 10.1002/mrm.27875] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 05/07/2019] [Accepted: 05/30/2019] [Indexed: 12/26/2022]
Abstract
PURPOSE To develop prospectively accelerated 3D CEST imaging using compressed sensing (CS), combined with a saturation scheme based on time-interleaved parallel transmission. METHODS A variable density pseudo-random sampling pattern with a centric elliptical k-space ordering was used for CS acceleration in 3D. Retrospective CS studies were performed with CEST phantoms to test the reconstruction scheme. Prospectively CS-accelerated 3D-CEST images were acquired in 10 healthy volunteers and 6 brain tumor patients with an acceleration factor (RCS ) of 4 and compared with conventional SENSE reconstructed images. Amide proton transfer weighted (APTw) signals under varied RF saturation powers were compared with varied acceleration factors. RESULTS The APTw signals obtained from the CS with acceleration factor of 4 were well-preserved as compared with the reference image (SENSE R = 2) both in retrospective phantom and prospective healthy volunteer studies. In the patient study, the APTw signals were significantly higher in the tumor region (gadolinium [Gd]-enhancing tumor core) than in the normal tissue (p < .001). There was no significant APTw difference between the CS-accelerated images and the reference image. The scan time of CS-accelerated 3D APTw imaging was dramatically reduced to 2:10 minutes (in-plane spatial resolution of 1.8 × 1.8 mm2 ; 15 slices with 4-mm slice thickness) as compared with SENSE (4:07 minutes). CONCLUSION Compressed sensing acceleration was successfully extended to 3D-CEST imaging without compromising CEST image quality and quantification. The CS-based CEST imaging can easily be integrated into clinical protocols and would be beneficial for a wide range of applications.
Collapse
Affiliation(s)
- Hye-Young Heo
- Divison of MR Research, Department of Radiology, Johns
Hopkins University, Baltimore, Maryland, USA
- F.M. Kirby Research Center for Functional Brain Imaging,
Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Xiang Xu
- Divison of MR Research, Department of Radiology, Johns
Hopkins University, Baltimore, Maryland, USA
- F.M. Kirby Research Center for Functional Brain Imaging,
Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Shanshan Jiang
- Divison of MR Research, Department of Radiology, Johns
Hopkins University, Baltimore, Maryland, USA
| | | | | | - Kristin J. Redmond
- Department of Radiation Oncology and Molecular Radiation
Science, Johns Hopkins University, Baltimore, Maryland, USA
| | - John Laterra
- F.M. Kirby Research Center for Functional Brain Imaging,
Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Neurology, Johns Hopkins University,
Baltimore, Maryland, USA
| | - Peter C.M. van Zijl
- Divison of MR Research, Department of Radiology, Johns
Hopkins University, Baltimore, Maryland, USA
- F.M. Kirby Research Center for Functional Brain Imaging,
Kennedy Krieger Institute, Baltimore, Maryland, USA
| | - Jinyuan Zhou
- Divison of MR Research, Department of Radiology, Johns
Hopkins University, Baltimore, Maryland, USA
- F.M. Kirby Research Center for Functional Brain Imaging,
Kennedy Krieger Institute, Baltimore, Maryland, USA
| |
Collapse
|
90
|
Schüre JR, Shrestha M, Breuer S, Deichmann R, Hattingen E, Wagner M, Pilatus U. The pH sensitivity of APT-CEST using phosphorus spectroscopy as a reference method. NMR IN BIOMEDICINE 2019; 32:e4125. [PMID: 31322308 DOI: 10.1002/nbm.4125] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 05/08/2019] [Accepted: 05/08/2019] [Indexed: 06/10/2023]
Abstract
The pH value is a potential physiological marker for clinical diagnosis as it is altered in pathologies such as tumors. While intracellular pH can be measured noninvasively via phosphorus spectroscopy (31 P MRSI), Amide Proton Transfer-Chemical Exchange Saturation Transfer (APT-CEST) MRI has been suggested as an alternative method for pH quantification. To assess the suitability of APT-CEST contrast for pH quantification, two approaches (magnetization transfer ratio asymmetry [MTRasym ] and Lorentzian difference analysis [LDA]) for analyzing the Z-spectrum have been correlated with pH values obtained by 31 P MRSI. Fourteen patients with glioblastoma and 12 healthy controls were included. In contrast to MTRasym , the LDA is modeling the direct water saturation and the semi-solid magnetization transfer, allowing a separate evaluation of the aliphatic nuclear Overhauser effect and the APT-CEST. The results of our study show that the pH values obtained by 31 P MRSI correspond well with both methods describing the APT-CEST contrast. Two-sample t-test showed significant differences in MTRasym , LDA and pH obtained by 31 P MRSI for regions of interest in glioblastoma, contralateral control areas and normal appearing white matter (P < 0.001). A slightly improved correlation between the amide signal and pH was found after performing LDA (r = 0.78) compared with MTRasym (r = 0.70). While both methods can be used to monitor pH changes, the LDA approach appears to be better suited.
Collapse
Affiliation(s)
- Jan-Rüdiger Schüre
- Department of Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Manoj Shrestha
- Brain Imaging Center (BIC), Goethe University Frankfurt, Frankfurt am Main, Germany
| | - Stella Breuer
- Department of Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Ralf Deichmann
- Brain Imaging Center (BIC), Goethe University Frankfurt, Frankfurt am Main, Germany
| | - Elke Hattingen
- Department of Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Marlies Wagner
- Department of Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Ulrich Pilatus
- Department of Neuroradiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
91
|
Damen FC, Tain RW, Thomas R, Li W, Tai L, Cai K. Evaluation of B 0-correction of relative CBF maps using tagging distance dependent Z-spectrum (TADDZ). Magn Reson Imaging 2019; 65:83-89. [PMID: 31669538 DOI: 10.1016/j.mri.2019.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 08/27/2019] [Accepted: 10/08/2019] [Indexed: 12/17/2022]
Abstract
Arterial spin labeling (ASL) MRI, based on endogenous contrast from blood water, is used in research and diagnosis of cerebral vascular conditions. However, artifacts due to imperfect imaging conditions such as B0-inhomogeneity (ΔB0) could lead to variations in the quantification of relative cerebral blood flow (CBF). In this study, we evaluate a new approach using tagging distance dependent Z-spectrum (TADDZ) data, similar to the ΔB0 corrections in the chemical exchange saturation transfer (CEST) experiments, to remove the imaging plane B0 inhomogeneity induced CBF artifacts in ASL MRI. Our results indicate that imaging-plane B0-inhomogeneity can lead to variations and errors in the relative CBF maps especially under small tagging distances. Along with an acquired B0 map, TADDZ data helps to eliminate B0-inhomogeneity induced artifacts in the resulting relative CBF maps. We demonstrated the effective use of TADDZ data to reduce variation while subjected to systematic changes in ΔB0. In addition, TADDZ corrected ASL MRI, with improved consistency, was shown to outperform conventional ASL MRI by differentiating the subtle CBF difference in Alzheimer's disease (AD) mice brains with different APOE genotypes.
Collapse
Affiliation(s)
- Frederick C Damen
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States
| | - Rong-Wen Tain
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States; Brain Imaging Research, University of California, Irvine, CA, United States
| | - Riya Thomas
- Department of Anatomy and Cell Biology, University of Illinois at Chicago, Chicago, IL, United States
| | - Weigo Li
- Research Resources Center, University of Illinois at Chicago, Chicago, IL, United States; Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States; Department of Radiology, Northwestern University, Chicago, IL, United States
| | - Leon Tai
- Department of Anatomy and Cell Biology, University of Illinois at Chicago, Chicago, IL, United States
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, United States; Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States; Center for MR Research, University of Illinois at Chicago, Chicago, IL, United States.
| |
Collapse
|
92
|
Sun PZ. Fast correction of B 0 field inhomogeneity for pH-specific magnetization transfer and relaxation normalized amide proton transfer imaging of acute ischemic stroke without Z-spectrum. Magn Reson Med 2019; 83:1688-1697. [PMID: 31631414 DOI: 10.1002/mrm.28040] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/17/2019] [Accepted: 09/23/2019] [Indexed: 01/04/2023]
Abstract
PURPOSE The magnetization transfer and relaxation normalized amide proton transfer (MRAPT) analysis is promising to provide a highly pH-specific mapping of tissue acidosis, complementing commonly used CEST asymmetry analysis. We aimed to develop a fast B0 inhomogeneity correction algorithm for acute stroke magnetization transfer and relaxation normalized amide proton transfer imaging without Z-spectral interpolation. METHODS The proposed fast field inhomogeneity correction describes B0 artifacts with linear regression. We compared the new algorithm with the routine interpolation correction approach in CEST imaging of a dual-pH phantom. The fast B0 correction was further evaluated in amide proton transfer imaging of normal and acute stroke rats. RESULTS Our phantom data showed that the proposed fast B0 inhomogeneity correction significantly improved pH MRI contrast, recovering over 80% of the pH MRI contrast-to-noise-ratio difference between the raw magnetization transfer ratio asymmetry and that using the routine interpolation-based B0 correction approach. In normal rat brains, the proposed fast B0 correction improved pH-specific MRI uniformity across the intact tissue, with the ratio of magnetization transfer and relaxation normalized amide proton transfer ratio being 10% of that without B0 inhomogeneity correction. In acute stroke rats, fast B0 inhomogeneity-corrected pH MRI reveals substantially improved pH lesion conspicuity, particularly in regions with nonnegligible B0 inhomogeneity. The pH MRI contrast-to-noise ratio between the ipsilateral diffusion lesion and contralateral normal tissue improved significantly with fast B0 correction (from 1.88 ± 0.48 to 2.20 ± 0.44, P < .01). CONCLUSIONS Our study established an expedient B0 inhomogeneity correction algorithm for fast pH imaging of acute ischemia.
Collapse
Affiliation(s)
- Phillip Zhe Sun
- Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.,Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, Georgia.,Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia
| |
Collapse
|
93
|
Thomas AM, Xu J, Calabresi PA, van Zijl PCM, Bulte JWM. Monitoring diffuse injury during disease progression in experimental autoimmune encephalomyelitis with on resonance variable delay multiple pulse (onVDMP) CEST MRI. Neuroimage 2019; 204:116245. [PMID: 31605825 DOI: 10.1016/j.neuroimage.2019.116245] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Revised: 09/16/2019] [Accepted: 10/03/2019] [Indexed: 12/24/2022] Open
Abstract
Multiple sclerosis (MS) is an autoimmune disorder that targets myelin proteins and results in extensive damage in the central nervous system in the form of focal lesions as well as diffuse molecular changes. Lesions are currently detected using T1-weighted, T2-weighted, and gadolinium-enhanced magnetic resonance imaging (MRI); however, monitoring such lesions has been shown to be a poor predictor of disease progression. Chemical exchange saturation transfer (CEST) MRI is sensitive to many of the biomolecules in the central nervous system altered in MS that cannot be detected using conventional MRI. We monitored disease progression in an experimental autoimmune encephalomyelitis (EAE) model of MS using on resonance variable delay multiple pulse (onVDMP) CEST MRI. Alterations in onVDMP signal were observed in regions responsible for hindlimb function throughout the central nervous system. Histological analysis revealed glial activation in areas highlighted in onVDMP CEST MRI. onVDMP signal changes in the 3rd ventricle preceded paralysis onset that could not be observed with conventional MRI techniques. Hence, the onVDMP CEST MRI signal has potential as a novel imaging biomarker and predictor of disease progression in MS.
Collapse
Affiliation(s)
- Aline M Thomas
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jiadi Xu
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Peter A Calabresi
- Department of Neurology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; The Solomon H. Snyder Department of Neuroscience, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Peter C M van Zijl
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA
| | - Jeff W M Bulte
- The Russell H. Morgan Department of Radiology and Radiological Science, Division of MR Research, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; Cellular Imaging Section and Vascular Biology Program, Institute for Cell Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD, USA; Department of Oncology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; Department of Biomedical Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA; Department of Chemical & Biomolecular Engineering, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
94
|
Goldenberg JM, Pagel MD. Assessments of tumor metabolism with CEST MRI. NMR IN BIOMEDICINE 2019; 32:e3943. [PMID: 29938857 PMCID: PMC7377947 DOI: 10.1002/nbm.3943] [Citation(s) in RCA: 56] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2018] [Revised: 04/13/2018] [Accepted: 04/18/2018] [Indexed: 05/06/2023]
Abstract
Chemical exchange saturation transfer (CEST) is a relatively new contrast mechanism for MRI. CEST MRI exploits a specific MR frequency (chemical shift) of a molecule while generating an image with good spatial resolution using standard MRI techniques, combining the specificity of MRS with the spatial resolution of MRI. Many CEST MRI acquisition methods have been developed to improve analyses of tumor metabolism. GluCEST, CrCEST, and LATEST can map glutamate, creatine, and lactate, which are important metabolites involved in tumor metabolism. GlucoCEST MRI tracks the pharmacokinetics of glucose transport and cell internalization within tumors. CatalyCEST MRI detects enzyme catalysis that changes a substrate CEST agent. AcidoCEST MRI measures extracellular pH of the tumor microenvironment by exploiting a ratio of two pH-dependent CEST signals. This review describes each technique, the technical issues involved with CEST MRI and each specific technique, and the merits and challenges associated with applying each CEST MRI technique to study tumor metabolism.
Collapse
Affiliation(s)
- Joshua M. Goldenberg
- Department of Pharmaceutical Sciences, The University of Arizona, Tucson, AZ, USA
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Mark D. Pagel
- Department of Cancer Systems Imaging, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| |
Collapse
|
95
|
Shaghaghi M, Chen W, Scotti A, Ye H, Zhang Y, Zhu W, Cai K. In vivo quantification of proton exchange rate in healthy human brains with omega plot. Quant Imaging Med Surg 2019; 9:1686-1696. [PMID: 31728312 DOI: 10.21037/qims.2019.08.06] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Background To implement omega plot method for in vivo mapping of proton exchange rates in human brain by taking into account the water direct saturation (DS) effect and multiple saturation transfer exchanging species in vivo. Methods Four Z-spectra were collected with chemical exchange saturation transfer (CEST) saturation power =1, 2, 3 & 4 µT. Water DS was estimated by fitting the Z-spectrum to a linear combination of multiple Lorentzian components and its contribution to the signal was subsequently removed. Exchange rate maps were derived by the omega plot, consisting of fitting the inverse of the signal intensity, Mz /(M 0-Mz ), as a function of 1/(γB1)2. Results The exchange rate values quantified with the DS removed omega plot were significantly higher in the GM region than in the WM region (616±29 vs. 575±20 s-1, P<0.001). Phantom studies confirmed that the exchange rates from DS-removed plots varied linearly with pH (R2=0.998) for the pH range of 6.2 to 7.4, whereas exchange rates from conventional omega plots failed to show such linearity in the entire physiological pH range. Conclusions The calculated exchange rate with DS-corrected omega plot is a weighted average for all saturation transfer exchanging proton species which contribute to Z-spectral signal. The healthy brain exchange rate map provided by DS-removed omega plots may serve as a baseline for detecting any pathological changes.
Collapse
Affiliation(s)
- Mehran Shaghaghi
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, USA
| | - Weiwei Chen
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, China
| | - Alessandro Scotti
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, USA.,Bioengieering, University of Illinois at Chicago, Chicago, IL, USA
| | - Haiqi Ye
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, China
| | - Yan Zhang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, China
| | - Wenzhen Zhu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, China
| | - Kejia Cai
- Department of Radiology, University of Illinois at Chicago, Chicago, IL, USA.,Bioengieering, University of Illinois at Chicago, Chicago, IL, USA.,Center for MR Research, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
96
|
Bie C, Liang Y, Zhang L, Zhao Y, Chen Y, Zhang X, He X, Song X. Motion correction of chemical exchange saturation transfer MRI series using robust principal component analysis (RPCA) and PCA. Quant Imaging Med Surg 2019; 9:1697-1713. [PMID: 31728313 PMCID: PMC6828584 DOI: 10.21037/qims.2019.09.14] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 09/10/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND Chemical exchange saturation transfer (CEST) MRI requires the acquisition of multiple saturation-weighted images and can last several minutes. Misalignments among these images, which are often due to the inevitable motion of the subject, will corrupt CEST contrast maps and result in large quantification errors. Therefore, the registration of the CEST series is critical. However, registration is challenging since common intensity-based registration algorithms may fail to differentiate CEST signals from motion artifacts. Herein, we studied how different patterns of motion affect CEST quantification and proposed a cascaded two-step registration scheme by utilizing features extracted from the entire Z-spectral image series instead of direct registration to a single image. METHODS The proposed approach is conducted in two stages: during the first coarse registration, the Z-spectral image series is decomposed by robust principal component analysis (RPCA) to separate CEST contrast from motion. The recomposed image series using only the low-rank component, which contains minimized motion, are averaged to generate a reference for the alignment of the image series. To further remove residual misalignments, the coarse registration is followed by a refinement stage, which uses PCA iteratively to generate motionless synthetic reference series with the first few principal components (PCs) that correspond to CEST contrast. In the end, the quality check is performed to exclude the images with unsuccessful registration. RESULTS The proposed registration scheme (RPCA + PCA_R) was assessed by both phantom experiments and in vivo data of tumor-bearing mouse brain, with simulated random rigid motion in different patterns applied to the acquired static Z-spectral image series. For comparison, previous correction schemes using an explicit image [either S0 or Ssat(∆ω)] as registration reference were also performed, named as S0_R and Ssat_R respectively. To illustrate the advantage of combination of RPCA and PCA, registration was also exploited using either only the RPCA-based method (RPCA_R) or only the PCA-based one (PCA_R). Compared with the above four methods, RPCA + PCA_R allowed for more accurate correction of the corrupted Z-spectral images, exhibiting smaller MTRasym(∆ω) error maps and lower residual Z-spectra referring to the static data. Among all the five correction methods, the corrected Z-spectral image series by RPCA + PCA_R and the resulting MTRasym(∆ω) maps achieved the highest correlation coefficients (CC) with respect to the static ones. CONCLUSIONS The registration scheme of RPCA + PCA_R provides robust motion correction between two specific Z-spectral images and among an entire image series, through extraction of the static component from the entire Z-spectra set and inclusion of a PCA-based refinement step. Therefore, this method can help improve CEST acquisition and quantification.
Collapse
Affiliation(s)
- Chongxue Bie
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yuhua Liang
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Lihong Zhang
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yingcheng Zhao
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yanrong Chen
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Xueru Zhang
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Xiaowei He
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Xiaolei Song
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| |
Collapse
|
97
|
Evans VS, Torrealdea F, Rega M, Brizmohun Appayya M, Latifoltojar A, Sidhu H, Kim M, Kujawa A, Punwani S, Golay X, Atkinson D. Optimization and repeatability of multipool chemical exchange saturation transfer MRI of the prostate at 3.0 T. J Magn Reson Imaging 2019; 50:1238-1250. [PMID: 30770603 PMCID: PMC6767527 DOI: 10.1002/jmri.26690] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 02/06/2019] [Accepted: 02/06/2019] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND Chemical exchange saturation transfer (CEST) can potentially support cancer imaging with metabolically derived information. Multiparametric prostate MRI has improved diagnosis but may benefit from additional information to reduce the need for biopsies. PURPOSE To optimize an acquisition and postprocessing protocol for 3.0 T multipool CEST analysis of prostate data and evaluate the repeatability of the technique. STUDY TYPE Prospective. SUBJECTS Five healthy volunteers (age range: 24-47 years; median age: 28 years) underwent two sessions (interval range: 7-27 days; median interval: 20 days) and two biopsy-proven prostate cancer patients were evaluated once. Patient 1 (71 years) had a Gleason 3 + 4 transition zone (TZ) tumor and patient 2 (55 years) had a Gleason 4 + 3 peripheral zone (PZ) tumor. FIELD STRENGTH 3.0 T. Sequences run: T2 -weighted turbo-spin-echo (TSE); diffusion-weighted imaging; CEST; WASABI (for B0 determination). ASSESSMENT Saturation, readout, and fit-model parameters were optimized to maximize in vivo amide and nuclear Overhauser effect (NOE) signals. Repeatability (intrasession and intersession) was evaluated in healthy volunteers. Subsequently, preliminary evaluation of signal differences was made in patients. Regions of interest were drawn by two post-FRCR board-certified readers, both with over 5 years of experience in multiparametric prostate MRI. STATISTICAL TESTS Repeatability was assessed using Bland-Altman analysis, coefficient of variation (CV), and 95% limits of agreement (LOA). Statistical significance of CEST contrast was calculated using a nonparametric Mann-Whitney U-test. RESULTS The optimized saturation scheme was found to be 60 sinc-Gaussian pulses with 40 msec pulse duration, at 50% duty-cycle with continuous-wave pulse equivalent B1 power (B1CWPE ) of 0.92 μT. The magnetization transfer (MT) contribution to the fit-model was centered at -1.27 ppm. Intersession coefficients of variation (CVs) of the amide, NOE, and magnetization transfer (MT) and asymmetric magnetization transfer ratio (MTRasym ) signals of 25%, 23%, 18%, and 200%, respectively, were observed. Fit-metric and MTRasym CVs agreed between readers to within 4 and 10 percentage points, respectively. DATA CONCLUSION Signal differences of 0.03-0.10 (17-43%) detectable depending upon pool, with MT the most repeatable (signal difference of 17-22% detectable). LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1238-1250.
Collapse
Affiliation(s)
| | | | - Marilena Rega
- Institute of Nuclear Medicine, University College London Hospital NHS Foundation Trust, University College HospitalLondonUK
| | | | | | - Harbir Sidhu
- Centre for Medical ImagingUniversity College LondonLondonUK
- Radiology DepartmentUniversity College London Hospital NHS Foundation Trust, University College HospitalLondonUK
| | - Mina Kim
- Institute of NeurologyUniversity College LondonLondonUK
| | - Aaron Kujawa
- Institute of NeurologyUniversity College LondonLondonUK
| | - Shonit Punwani
- Centre for Medical ImagingUniversity College LondonLondonUK
| | - Xavier Golay
- Institute of NeurologyUniversity College LondonLondonUK
| | - David Atkinson
- Centre for Medical ImagingUniversity College LondonLondonUK
| |
Collapse
|
98
|
Zhang L, Zhao Y, Chen Y, Bie C, Liang Y, He X, Song X. Voxel-wise Optimization of Pseudo Voigt Profile (VOPVP) for Z-spectra fitting in chemical exchange saturation transfer (CEST) MRI. Quant Imaging Med Surg 2019; 9:1714-1730. [PMID: 31728314 PMCID: PMC6828582 DOI: 10.21037/qims.2019.10.01] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 09/29/2019] [Indexed: 12/22/2022]
Abstract
BACKGROUND Chemical exchange saturation transfer (CEST) MRI is a promising approach for detecting biochemical alterations in cancers and neurological diseases, but the quantification can be challenging. Among numerous quantification methods, Lorentzian difference (LD) is relatively simple and widely used, which employs Lorentzian line-shape as a reference to describe the direct saturation (DS) of water and takes account of difference against experimental CEST spectra data. However, LD often overestimates CEST and nuclear overhauser enhancement (NOE) effects. Specifically, for fast-exchanging CEST species require higher saturation power (B1_sat) or in the presence of strong magnetization transfer (MT) contrast, Z-spectrum appears more like a Gaussian line-shape rather than a Lorentzian line-shape. METHODS To improve the conventional LD analysis, the present study developed and validated a novel fitting algorithm through a linear combination of Gaussian and Lorentzian function as the reference spectra, namely, Voxel-wise Optimization of Pseudo Voigt Profile (VOPVP). The experimental Z-spectra were pre-fitted with Gaussian and Lorentzian method independently, in order to determine Lorentzian proportionality coefficient (a). To further compensate for the line-shape changes under different B1_sat's, a B1-dependent adjustment was applied to the experimental Z-spectra (Z_exp) according to the prior knowledge learned from 5-pool Bloch equation-based simulations at a range of B1_sat's. Then, the obtained Z-spectra (Z_B1adj) was fitted by the previously defined VOPVP function. Considering the asymmetric component of MT, the positive- and negative-side of Z-spectra were fitted separately, while the middle part (-0.6 to 0.6 ppm, consisted primarily of DS) was fitted using Lorentzian function. Finally, the difference between Z_VOPVP and Z_exp was defined as the CEST and NOE contrast. To validate our VOPVP method, an extensive simulation of CEST Z-spectra was performed using 5-pool model and 6-pool model with greater MT component. RESULTS In comparison with LD approach, VOPVP exhibited lower sum of squares due to error (SSE) and higher goodness of fit (R-square) for the experimental Z-spectra at all B1_sat. Moreover, the results indicated that VOPVP fitting improved the overestimated contributions from amide proton transfer (APT) and NOE through LD at all B1_sat. Despite that the relationship for B1-dependent adjustment was pre-determined using a single 5-pool model, the VOPVP fittings obtained accurate quantification for multiple 6-pool models with a range of T1w's and T2w's. The robustness of VOPVP fitting was also proved by simulations using 3T parameters. Furthermore, we assessed VOPVP in vivo in a glioblastoma-bearing mouse. Compared to LD maps, VOPVP quantification maps displayed higher contrast-to-noise ratio between tumor and normal contralateral tissue for APT, glutamate and nuclear overhauser effect (NOE), when B1_sat >1 µT. CONCLUSIONS As an improvement of LD method, VOPVP fitting can serve as a simple, robust and more accurate approach for quantifying CEST and NOE contrast.
Collapse
Affiliation(s)
- Lihong Zhang
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yingcheng Zhao
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yanrong Chen
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Chongxue Bie
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Yuhua Liang
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Xiaowei He
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| | - Xiaolei Song
- School of Information Science and Technology, Northwest University, Xi'an 710127, China
| |
Collapse
|
99
|
Liu J, Li C, Chen Y, Lv X, Lv Y, Zhou J, Xi S, Dou W, Qian L, Zheng H, Wu Y, Chen Z. Diagnostic performance of multiparametric MRI in the evaluation of treatment response in glioma patients at 3T. J Magn Reson Imaging 2019; 51:1154-1161. [DOI: 10.1002/jmri.26900] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 07/30/2019] [Accepted: 08/01/2019] [Indexed: 01/07/2023] Open
Affiliation(s)
- Jie Liu
- Paul C. Lauterbur Research Center for Biomedical ImagingShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences Shenzhen Guangdong China
| | - Cong Li
- Department of NeurosurgerySun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | - Yinsheng Chen
- Department of NeurosurgerySun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | - Xiaofei Lv
- Department of Medical ImagingSun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | - Yanchun Lv
- Department of Medical ImagingSun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | - Jian Zhou
- Department of Medical ImagingSun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | - Shaoyan Xi
- Department of PathologySun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| | | | | | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical ImagingShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences Shenzhen Guangdong China
| | - Yin Wu
- Paul C. Lauterbur Research Center for Biomedical ImagingShenzhen Institutes of Advanced Technology, Chinese Academy of Sciences Shenzhen Guangdong China
| | - Zhongping Chen
- Department of NeurosurgerySun Yat‐Sen University Cancer Center Guangzhou Guangdong China
| |
Collapse
|
100
|
Zhang Y, Heo HY, Jiang S, Zhou J, Bottomley PA. Fast 3D chemical exchange saturation transfer imaging with variably-accelerated sensitivity encoding (vSENSE). Magn Reson Med 2019; 82:2046-2061. [PMID: 31264278 DOI: 10.1002/mrm.27881] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Revised: 05/31/2019] [Accepted: 06/02/2019] [Indexed: 12/20/2022]
Abstract
PURPOSE To extend the variably-accelerated sensitivity encoding (vSENSE) method from 2D to 3D for fast chemical exchange saturation transfer (CEST) imaging, and prospectively implement it for clinical MRI. METHODS The CEST scans were acquired from 7 normal volunteers and 15 brain tumor patients using a 3T clinical scanner. The 2D and 3D "artifact suppression" (AS) vSENSE algorithms were applied to generate sensitivity maps from a first scan acquired with conventional SENSE-accelerated 2D and 3D CEST data. The AS sensitivity maps were then applied to reconstruct the other CEST frames at higher acceleration factors. Both retrospective and prospective acceleration in phase-encoding and slice-encoding dimensions were implemented. RESULTS Applying the 2D AS vSENSE algorithm to a 2-fold undersampled 3.5-ppm CEST frame halved the scan time of conventional SENSE, while generating essentially identical reconstruction errors (p ≈ 1.0). The 3D AS vSENSE algorithm permitted prospective acceleration by up to 8-fold, in total, from phase-encoding and slice-encoding directions for individual source CEST images, and an overall speed-up in scan time of 5-fold. The resulting vSENSE-accelerated amide proton transfer-weighted images agreed with conventional 2-fold-accelerated SENSE CEST results in brain tumor patients and healthy volunteers. Importantly, the vSENSE method eliminated unfolding artifacts in the slice-encoding direction that compromised conventional SENSE CEST scans. CONCLUSION The vSENSE method can be extended to 3D CEST imaging to provide higher acceleration factors than conventional SENSE without compromising accuracy.
Collapse
Affiliation(s)
- Yi Zhang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.,Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Hye-Young Heo
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Shanshan Jiang
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Jinyuan Zhou
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Paul A Bottomley
- Division of MR Research, Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| |
Collapse
|